A Division of Tomarco Contractor Specialties
www.CEASattachments.com
(877) GOO-CEAS(877) 466-2327
Designed by professionals for professionals!
Innovative Labor Saving Solutions Since 1977
Elec
trica
l
Low
Vol
tage
HVAC
Plum
bing
Mec
hani
cal
Acous
tical
CONSTRUCTION APPLICATION PRODUCT CATALOG
C A B L E S U P P O R T S
Co
nst
ruct
ion
En
gin
ee
red
Att
ach
me
nt
So
luti
on
s S
ince
19
77
Wedgy Introduction 2-4 Wedgy Easy Installation Example 5 Traditional Supports vs the Wedgy Cable Support System 6 Wedgy Cloud Solutions 7Wedgy 600 Series Attachment Options 8-9 Concrete Attachments 10-11 Steel/Metal Attachments 12 Wood Attachments 13 Cast-in-Place Attachments 14-15 Other Attachment Options 15 Wedgy 600 Series Assemblies 16-56 Wedgy Cable Support Applications 57 Wedgy 700 Series Electrical Low Voltage Cable Support Product Index 58-59 700 Series Electrical/Low Voltage Assemblies 60-101Wedgy 800 Series HVAC Cable Support Product Index 102-103 800 Series HVAC Assemblies 104-149Wedgy 900 Series Plumbing/Piping Cable Support Product Index 150-151 900 Series Plumbing/Piping Assemblies 152-167Wedgy Technical Data Wedgy Device Capacities 168 How to Determine Loads at Support Locations 168 Support Requirements for Ceiling Mounted Light Fixtures 169 Basic Element Weight Tables for Electrical Conduit 169 How to Determine Wedgy Cable Lengths 170 Support Requirements for Ceiling Mounted Air Terminals 171 Rectangle Duct Weight Tables 172 Round Duct Weight Tables 173 Pipe Weight Tables 174 CEAS Wedgy Manufacturers Recomendations 175Wedgy Cable Support Accessories and Installation Tools 176-179
C a b l e S u p p o r t S o l u t i o n s
Table of ContentsReference Page #
Wedgy IntroductionWEDGY12 & WEDGY23 Devices
Install cable in the direcion of the arrow on the release tab.
U.S. Patent D737,134
To create the loop install the cable through the open hole on the opposing side.
To release the cable, push the Release Tabs forward in the direction of the arrow.
WE
DG
Y
W
ED
GY
WE
DG
Y
W
ED
GY
Device Capacities
Based on a 5:1 SWL
No. 1 Cable
No. 2 Cable
No. 3 Cable
77#
158#
314#
2
Wedgy Introduction ContinuedSingle Wedgy Cable Device
SWP2 or 3 Cable Device
Fastball Device
U.S. Patent D737,134
U.S. Patent D737,134
U.S. Patent D737,134
1) Insert SWP through channel2) Insert cable through plunger to desired length3) To release, push plunger down and pull cable4) Once the utility is adjusted to the desired elevation the plunger can be removed.
1) Insert cable through plunger to desired length2) To release, push plunger down and pull cable3) Once the utility is adjusted to the desired elevation the plunger can be removed.
NOTE: The SW23 is only sold pressed into channel or strut
Device Capacitiesinto 16g Channel
Based on a 5:1 SWL and a reduction taken for the potential of eccentric loading
No. 2 Cable
No. 3 Cable112#
Device Capacitiesinto 12g Channel
No. 2 Cable
No. 3 Cable
125#
231#
Based on a 5:1 SWL and a reduction taken
for the potential of eccentric loading
Device Capacitiesinto 12g Slotted StrutNo. 2 Cable
No. 3 Cable
126#
223#
Once you have inserted cable into fastball twist wing bolt until it touches cable then turn an additional:
• 1 Turn for No. 1 CABLE• 1-1/4 Turns for No. 2 CABLE• 1-1/2 Turns for No. 3 CABLE
Fastball Allowables
No. 1 Cable
No. 2 Cable
No. 3 Cable
22 lbs
78 lbs
130 lbs
Designed by professionals for professionals!
Sway Bracing Light Fixture with 2 Fastballs
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m 3
Co
nst
ruct
ion
En
gin
ee
red
Att
ach
me
nt
So
luti
on
s S
ince
19
77
Flex Saddle Corner Cradle
Wedgy Introduction Continued
Part Number: CC
C a b l e S u p p o r t S o l u t i o n s
Page62
Page62
• Ceiling Mounted Fixtures can be installed prior to the T-bar• Once the T-bar is installed the lights can be lowered into place• The cables at each corner satisfy the safety wire requirements of the light fixture in Seismic Design Categories C (Ip=1.5), D, E and F.
WEDGY
TIPSINSTALLATION
Part Number
5”- 6” Flex
7”- 10” Flex
12”- 14” Flex
16”- 18” Flex
FS12
FS18
FS24
FS31
4
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Wedgy “Easy” Installation
Desig
ned
by p
rofessio
nals fo
r pro
fession
als!
2 ScrewAnchor to
the Concrete
Attach device to ductwhen it can be reached from
the ground
PICTURED DSCL2 or DSCL3
Lower Attachment
To raise the duct simply pull morecable through the device.
To release the cable and lower theduct depress the black plunger.
3 AttachAttach Wedgy Device to Duct
4 AdjustCable to Desired
Length
It doesn’t get any easier than this...
• SMACNA Verified!• Safest and Fastest method of support for HVAC Ductwork.• Engineered Submittal Documents• Simple ordering process.
PICTUREDFig 601
90° Tapcon Concrete Screw
Anchor
1) Insert cable through plunger to desired length2) To release, push plunger down and pull cable3) Once the utility is adjusted to the desired elevation the plunger can be removed.
1 DrillHole forAnchor
PICTUREDRoto Hammer
PICTUREDImpact Pole Tool
PICTURED DSCU2 or DSCU3
Upper Attachment
Values based on a 5:1 SWL with all testing performed into
24g sheet metal.
Illustrations arenot to scale.See all attachment options on pages 10-15
DSCU2 or DSCU3 Cable Capacity
No. 2 Cable
No. 3 Cable103#
206# per set
DSCL2 or DSCL3 Cable Capacity
No. 2 Cable
No. 3 Cable173#
346# per set
Innovative, Labor Saving Solutions
5
Co
nst
ruct
ion
En
gin
ee
red
Att
ach
me
nt
So
luti
on
s S
ince
19
77
The Wedgy Support System
50 Prefabricated Trapezes
50 Prefabricated Loop Hangers
50 Fig 726 Prefabricated Trapezes
50 Fig 900 Prefabricated Loop Hangers
• Reduces shipping costs• Reduces material handling costs• Reduces coordination issues• Simplifies material ordering• Reduces installation costs
• All Wedgy assemblies are shipped with the appropriate fasteners
• Submittal documents are prepared and stamped be a structural engineer
36” wide with 60” threaded rodNO anchors are included
1-1/2” Loop Hanger 60” threaded rodNO anchors are included
36” wide with 60” cablesALL anchors are included
1-1/2” Loop Hanger with 60” cables ALL anchors are included
VS
VS
VS
Trapezes shown have the Single Wedgys pressed into them with the cable and fasteners assembled and in the buckets
Loop Hangers shown have the SW2 or SW3 devices pressed into them with the cable and fasteners assembled and in the buckets.
It doesn’t get any easier than this...
W e d g y C a b l e S u p p o r t S o l u t i o n s
Traditional Prefabricated Supports
6
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
REAL WORLD
SOLUTIONS
CLOUD
7
Co
nst
ruct
ion
En
gin
ee
red
Att
ach
me
nt
So
luti
on
s S
ince
19
77
6 0 0 S e r i e s C a b l e A t t a c h m e n t O p t i o n s
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m8
6 0 0 S e r i e s C a b l e A t t a c h m e n t O p t i o n s
Attachment Options
Pin and ClipsTapcon Screw AnchorsWedge AnchorsTie Wire Wedge and Spike Anchors
Wedgy Concrete Connections
Wood EyecableTimber PinsPull Down ClampsAB 45° and 90° Clip and Hex Lags
Wedgy Wood Connections
Beam LoopsSelf Drilling & Sharp PointsHammer on Beam ClampsAB 45° and 90° Clip and Screws
Wedgy Steel/Metal Connections
Cast-in-Place WedgyCast-in-Place Rebar and LoopSDI and PIP Blue Banger Hangers
Cast-in-Place Connections
Desig
ned
by p
rofessio
nals fo
r pro
fession
als!
PRE-A
SSEM
BLED
ATT
ACHM
ENTS
SAVES
LABO
R
SAVES
TIM
E
STEELMETAL
CEAS offers a complete line of attachment options for any installment application. Designed by professionals, for professionals, and engineered to save you time, labor and money.
9
Fig 600-1 thru 600-4 - Concrete Connections
Attachment Index
CO
NC
RE
TE
CO
NN
EC
TIO
NS
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Fig 600-11-1/8” Powers Pin and Clip
Fig 600-27/8” Powers Pin and Clip
Fig 600-31-1/8” Ramset Pin and Clip
Fig 600-47/8” Ramset Pin and Clip
Footnotes:1) A .77 reduction factor must be applied to capacities when used in an eccentric load condition. This reduction accounts for 65% of the load on each vertical support. (Capacity X .77 = Allowable Load in eccentric conditions)2) These values were derived from a legacy report based on the 2000 International Building Code.
Complete Attachment Solutions
Option# Order Option Description Part# Substrate Embed Load (Lbs)
600-1 C01 Powers Pin and Clip 50370
3,000PSI NWC
1-1/8”
95
3,000PSI NWC (at 45°) 190
3,000PSI LWC - 3" Deck 120
3,000PSI LWC - 3" Deck (at 45°) 145
600-2 C02 Powers Pin and Clip 50364
3,000PSI NWC
7/8”
75
3,000PSI NWC (at 45°) 145
3,000PSI LWC - 3" Deck 55
3,000PSI LWC - 3" Deck (at 45°) 120
600-3 C03 Ramset Pin and Clip SDC125
4,000PSI NWC
1-1/8”
130
4,000PSI NWC (at 45°) 103
3,000PSI LWC - 3" Deck Upper Flute 106
3,000PSI LWC - 3" Deck Upper Flute (at 45°) 112
3,000PSI LWC - 3" Deck Lower Flute 94
3,000PSI LWC - 3" Deck Lower Flute (at 45°) 99
600-4 C04 Ramset Pin and Clip SPC784,000PSI NWC
3/4”155
4,000PSI NWC (at 45°) 120
Illustrations are not to scale
Page16
10
Fig 601 thru 606 - Concrete Connections
6 0 0 C o n c r e t e O p t i o n s CO
NC
RE
TE
CO
NN
EC
TIO
NS
Attachment Index
Footnotes:1) A .77 reduction factor must be applied to capacities when used in an eccentric load condition. This reduction accounts for 65% of the load on each vertical support. (Capacity X .77 = Allowable Load in eccentric conditions)2) These values were derived from a legacy report based on the 2000 International Building Code.
Fig 60190° Tapcon Concrete
Screw Anchor
Fig 60290° Wedge
Screw Anchor
Fig 60345° Tapcon Concrete
Screw Anchor
Fig 60445° Wedge
Anchor
Fig 605Tie Wire
Wedge Anchor
Fig 606Tie Wire
Spike Anchor
Option# Order Option Description Part# Substrate Embed Load (Lbs)
601-1 C011/4” x 2-1/4” Tapcon Concrete Screw Anchor (1/4” Hole in Concrete Required)
242923,000PSI NWC - 4” Min Thick 2” 183
3,000PSI LWC - 4” Min Thick 2” 110
601-2 C023/8” x 3” Tapcon Concrete Screw Anchor (3/8” Hole in Concrete Required)
504033,000PSI NWC - 4” Min Thick 2-3/4” 315
3,000PSI LWC - 4” Min Thick 2-3/4” 215
602-1 C011/4” x 3-1/4” Wedge Anchor (Non-Seismic Non-Cracked Concrete)
7404SD13,000PSI LWC - 3.25” Min Thick 1.5” 541
3,000PSI NWC - 3.25” Min Thick 1.5” 541
602-2 C02 3/8” x 3” Wedge Anchor 7413SD23,000PSI LWC - 3.75” Min Thick 2” 363
3,000PSI NWC - 3.75” Min Thick 2” 261
603-1 C011/4” x 2-1/4” Tapcon Concrete Screw Anchor (1/4” Hole in Concrete Required)
242923,000PSI NWC - 4” Min Thick 2” 144
3,000PSI LWC - 4” Min Thick 2” 92
603-2 C023/8” x 3” Tapcon Concrete Screw Anchor (3/8” Hole in Concrete Required)
504033,000PSI NWC - 4” Min Thick 2-3/4” 245
3,000PSI LWC - 4” Min Thick 2-3/4” 151
604-1 C011/4” x 3-1/4” Wedge Anchor (Non-Seismic Non-Cracked Concrete)
7404SD13,000PSI LWC - 3.25” Min Thick 1.5” 374
3,000PSI NWC - 3.25” Min Thick 1.5” 374
604-2 C02 3/8” x 3” Wedge Anchor 7413SD23,000PSI LWC - 3.75” Min Thick 2” 279
3,000PSI NWC - 3.75” Min Thick 2” 168
6052 -Tie Wire Wedge Anchor (Non-Seismic Non-Cracked Concrete)
7409SD1
3,000PSI LWC - 3” Min Thick
1-1/8”
110
3,000PSI LWC - 3” Min Thick (at 45°) 90
2,000PSI NWC - 3” Min Thick 155
2,000PSI NWC - 3” Min Thick (at 45°) 112
6062 -Tie Wire Spike Anchor (Non-Seismic Non-Cracked Concrete)
3759
3,000PSI LWC - 3” Min Thick
1-1/4”
70
3,000PSI LWC - 3” Min Thick (at 45°) 62
3,000PSI NWC - 3” Min Thick 150
3,000PSI NWC - 3” Min Thick (at 45°) 117
Illustrations are not to scale
Page17
Page18
Page19
Page20
Page21
Page22
11
STEELMETAL
Fig 620 thru 627 - Steel Connections
6 0 0 S t e e l / M e t a l O p t i o n s
Attachment Index
ST
EE
L/M
ET
AL
CO
NN
EC
TIO
NS
Fig 621-1Wedgy with
Metal Eyecable
Fig 620Wedgy with Loop
Fig 622Wedgy with Bar Joist Pull-down
Clamp
Fig 623Wedgy with
Hammer-on Beam Clamp
Fig 624AB 90° Clip
with #10 Screw
Fig 626SP 90° Clip
with x 2 With #10 Screws
Fig 627SP45° Clip
with x 2 With #10 Screws
Fig 628Snap Hook
Metal Deck Metal Deck
Fig 625AB 45° Clip
With #10 Screw
Footnotes:1) A .77 reduction factor must be applied to capacities when used in an eccentric load condition. This reduction accounts for 65% of the load on each vertical support. (Capacity X .77 = Allowable Load in eccentric conditions)2) These values were derived from a legacy report based on the 2000 International Building Code.
Option# Order Option Description Substrate Load (Lbs)
620 - Loop Connection Steel 314
621-1 C01 Metal Eyelag - 1/4” x 3/4” (2” OAL) 20g 20g minimum 125
621-2 C02 Metal Eyelag - 1/4” x 2” (3-1/4” OAL) 20g 20g minimum 125
622 - Stiffy Bar Joist Pull-down Clamp 1/8” - 3/4” Steel 300
623 - Stiffy Hammer-on Beam Clamp 1/8” - 3/4” Steel 200
624-1 C01 AB90 - #10 X 1-1/4” HWH Self Driller
20g Sheet Metal 104
18g Sheet Metal 148
16g Sheet Metal 194
14g Sheet Metal 267
624-2 C02 AB90 - #10 X 1-1/4” HWH Sharp Point22g Sheet Metal 46
20g Sheet Metal 106
625-1 C01 AB45 - #10 X 1-1/4” HWH Self Driller
20g Sheet Metal 99
18g Sheet Metal 144
16g Sheet Metal 184
14g Sheet Metal 280
625-2 C02 AB45 - #10 X 1-1/4” HWH Sharp Point22g Sheet Metal 44
20g Sheet Metal 101
626-1 C01 SP90 - #10 X 1-1/4” HWH Self Driller
20g Sheet Metal 207
18g Sheet Metal 295
16g Sheet Metal 388
14g Sheet Metal 541
626-2 C02 SP90 - #10 X 1-1/4” HWH Sharp Point22g Sheet Metal 92
20g Sheet Metal 212
627-1 C01 SP45 - #10 X 1-1/4” HWH Self Driller
20g Sheet Metal 198
18g Sheet Metal 287
16g Sheet Metal 396
14g Sheet Metal 472
627-2 C02 SP45 - #10 X 1-1/4” HWH Sharp Point22g Sheet Metal 88
20g Sheet Metal 202
628 - Snap Hook 100
Illustrations are not to scale
Illustrations are not to scale
Page23
Page24
Page25
Page26
Page27
Page28
Page29
Page30
Page31
12
Fig 640 thru 644 - Wood Connections
6 0 0 W o o d O p t i o n s WO
OD
CO
NN
EC
TIO
NS
Attachment Index
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Fig 641Wedgy with Timberpin
Fig 642Wedgy with Wood Pull-
down Clamp
Fig 643AB 90° Clip
Hex Lag
Fig 644AB 45° Clip
Hex Lag
Fig 640Wedgy with
Wood Eyecable
Lumber Cross Section
Footnotes:1) A .77 reduction factor must be applied to capacities when used in an eccentric load condition. This reduction accounts for 65% of the load on each vertical support. (Capacity X .77 = Allowable Load in eccentric conditions)2) A 3/8” minimum edge distance and 1‐3/4” end distance is required for 1/4” diameter hex lags into wood.3) These values were derived from a legacy report based on the 1997 Uniform Building Code4) Side loads are typically not permitted on wood members. Consult with the Structural Engineer of Record for project specific requirements.
Complete Attachment Solutions
Option# Order Option Description Substrate Load (Lbs)
640-13 C01Wood Eyelag - 1/4” x 3”
Doug Fir or Glulam
270
Wood Eyelag - 1/4” x 3” at 45° 140
640-23 C02Wood Eyelag - 1/4” x 4” 270
Wood Eyelag - 1/4” x 4” at 45° 140
640-33 C03Wood Eyelag - 1/4” x 5” 270
Wood Eyelag - 1/4” x 5” at 45° 140
641 - Timberpin and Clip - PDCTP250 100
642-1 C01 Stiffy Wood Pull Down Beam Clamp - Nom. 2” Lumber
133642-2 C02 Stiffy Wood Pull Down Beam Clamp - Nom. 4” Lumber
642-3 C03 Stiffy Wood Pull Down Beam Clamp - Nom. 6” Lumber
643 - AB90 - 90° Clip and 1/4” x 2-1/2” Hex Lag2 216
644 - AB45 - 45° Clip and 1/4” x 2-1/2” Hex Lag2 130
Illustrations are not to scale
Page32
Page34
Page33
Page35
Page36
13
Fig 660 thru 672 - Cast-in-place Connections
Attachment Index
CA
ST
-IN
-PL
AC
E C
ON
NE
CT
ION
S
6 0 0 C a s t - i n - P l a c e O p t i o n s
Fig 6711/4” x 4”Eyebolt
Concrete Anchors
Fig 6653/8” x 2-1/2”Wedgy Stud
Fig 6701/4” x 2-1/2”Wedgy Stud
Footnotes:1) A .77 reduction factor must be applied to capacities when used in an eccentric load condition. This reduction accounts for 65% of the load on each vertical support. (Capacity X .77 = Allowable Load in eccentric conditions)
2) These values were derived from a legacy report.
Steel Deck with or without Concrete PourFor No Concrete
Steel Decks
Steel Deck Concrete Pour
Form Pour Deck Concrete Pour
Option# OrderOption Description Substrate Load
(Lbs)
Steel Deck - With or Without Concrete Pour
660 -Cast-in-Place Pigtail - into 20g Metal Deck with NO CONCRETE FILL
20g133
Cast-in-Place Pigtail - into 20g Metal Deck with concrete 300
661 -Cast-in-Place Rebar - into 22g Metal Deck with NO CONCRETE FILL
22g200
Cast-in-Place Pigtail - into 20g Metal Deck with concrete 314
664 - Loop with 1-1/4” Washer into Min 22g Metal Deck with NO CONCRETE FILL 22g 200
Blue Banger Hanger Insert Anchors
662 - 1/4” x 5” Eyebolt (SDI143812 Blue Banger)SDI
BlueBanger Hanger
314
663-1 C01 AB45 - 45° Clip and 3/8” x 1-1/2” Hex Bolt (SDI143812 Blue Banger) 314
663-2 C02 AB45 - 45° Clip and 3/8” x 1-3/4” Hex Bolt (SDI381258 Blue Banger) 314
667 - 3/8” x 5” Wedgy Stud 314
665 - 3/8” x 2-1/2” Wedgy Stud (PIP or RDI Blue Banger)
PIPBlue
Banger Hanger
314
670 - 1/4” x 2-1/2” Wedgy Stud (PIP143812 or RDI Blue Banger) 314
671 - 1/4” x 4” Eyebolt (PIP143812 Blue Banger) 314
672-1 C01 AB90 - 90° Clip and 3/8” x 1-1/4” Hex Bolt (PIP143812 Blue Banger) 314
672-2 C02 AB90 - 90° Clip and 3/8” x 1-3/4” Hex Bolt (PIP381258 Blue Banger) 314
Illustrations are not to scale
Wedgy Stud Pole
Page42
Page46
Page47
Page48
Page42
Fig 6653/8” x 2-1/2”Wedgy Stud
Fig 660Cast-in-Place
Wedgy
Fig 661Cast-in-Place
Rebar
Fig 664Cast-in-Place
Loop
Page37
Page41
Page38
Fig 6621/4” x 5”Eyebolt
Fig 66345° Clip with 3/8”
Hex Bolt
Fig 6673/8” x 5”
Wedgy Stud
Page39
Page40
Page43
Approved
Fig 67245° Clip with3/8” Hex Bolt
JustPush It!
14
Fig 680 thru 683 - Other Connections
Complete Attachment Solutions
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
PRPIP Concrete Anchors
Fig 6683/8” x 2-1/2”Wedgy Studfor Push Rod
Fig 6693/8” x 5”
Wedgy Studfor Push Rod
Option# OrderOption Description Substrate Load
(Lbs)
Push Rod Insert Anchors668 - Wedgy 3/8” x 1-1/2” Stud with Engagment Markings PRPIP 314
669 - Wedgy 3/8” x 5” Stud with Engagment Markings PRSDI 314
Option# Order Option Description Part#
680-1 C01 Wedgy with 90° Clip Only - Cable Tied Through the (3/8”) Large HoleAB90
680-2 C02 Wedgy with 90° Clip Only - Cable Tied Through the (3/16”) Small Hole
681-1 C01 Wedgy with 45° Clip Only - Cable Tied Through the (3/8”) Large HoleAB45
681-2 C02 Wedgy with 45° Clip Only - Cable Tied Through the (3/16”) Small Hole
682 - Wedgy - 90° Bracket with 1/4” Anchor Hole 682
683 - Wedgy - 90° Bracket with 3/8” Anchor Hole 683
Fig 680Wedgy with AB 90°
Blank Clip Only
Fig 68290° Bracket with 1/4”
Anchor Hole
Fig 681Wedgy with AB 45°
Blank Clip Only
Fig 68390° Bracket with 3/8”
Anchor Hole
Illustrations are not to scale
Wed
gy
Stu
d P
ole Page
44Page45
Page49
Page50
Page51
Page52
O t h e r C o n n e c t i o n s
It doesn’t get any easier than this...
JustPush It!
Wedgy Stud Installation Tool
• Saves labor• Safest and fastest installation
• Dramatically increases productivity• Takes the guess work out of installation
1) Insert attachment into the Wedgy Stud Pole. 2) Push to engage. Reverse thread to release. 3) Load values achieved when Engagement Marking is flush up against protruding plastic sleeve.
15
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-60001010101 100
77
CEA-60002010101 100
120
CEA-60003010101 100
120
6' CEA-60001020101 100 CEA-60002020101 100 CEA-60003020101 50
9' CEA-60001030101 50 CEA-60002030101 50 CEA-60003030101 50
12' CEA-60001040101 50 CEA-60002040101 50 CEA-60003040101 50
15' CEA-60001050101 50 CEA-60002050101 50 CEA-60003050101 50
WEDGY - D01 18' CEA-60001060101 50 CEA-60002060101 50 CEA-60003060101 25
3' CEA-60002010102 25
120
CEA-60003010102 25
120
6' CEA-60002020102 25 CEA-60003020102 25
9' CEA-60002030102 25 CEA-60003030102 25
12' CEA-60002040102 25 CEA-60003040102 25
15' CEA-60002050102 25 CEA-60003050102 25
DSCL2 or 3 - D02 18' CEA-60002060102 25 CEA-60003060102 25
3' CEA-60002010103 25
104
CEA-60003010103 25
104
6' CEA-60002020103 25 CEA-60003020103 25
9' CEA-60002030103 25 CEA-60003030103 25
12' CEA-60002040103 25 CEA-60003040103 25
15' CEA-60002050103 25 CEA-60003050103 25
DSCU2 or 3 - D03 18' CEA-60002060103 25 CEA-60003060103 25
3' CEA-60001010104 25
77
CEA-60002010104 25 Upper Attach CEA-60003010104 25 Upper Attach
6' CEA-60001020104 25 CEA-60002020104 25104
CEA-60003020104 25104
9' CEA-60001030104 25 CEA-60002030104 25 CEA-60003030104 25
12' CEA-60001040104 25 CEA-60002040104 25 Lower Attach CEA-60003040104 25 Lower Attach
15' CEA-60001050104 25 CEA-60002050104 25120
CEA-60003050104 25120
WEDGY & DSC - D04 18' CEA-60001060104 25 CEA-60002060104 25 CEA-60003060104 25
3' CEA-60002010105 100
120
CEA-60003010105 100
120
6' CEA-60002020105 100 CEA-60003020105 50
9' CEA-60002030105 50 CEA-60003030105 50
12' CEA-60002040105 50 CEA-60003040105 50
15' CEA-60002050105 50 CEA-60003050105 50
SWP2 or 3 - D05 18' CEA-60002060105 50 CEA-60003060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
60
0
Illustrations are not to scale
Part Numbers
Wedgy with Pin and Clip
Fig 600
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 10.• Capacities Shown in the table below account for the connection to the structure with 1-1/8” embedment into 3,000 PSI LWC.• C04 = 3/4” Embedment for Post Tension projects with limited embedment requirements.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Stiffy Toolwith Standard
Nosepiece
Example:CEA-60002030101
A02 = No. 2 CableB03 = 9’ CableC01 = 600-1 Powers Pin and Clip with 1-1/8” Embedment. (See Page 10)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
16
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-60101010101 100
77
CEA-60102010101 100
158
CEA-60103010101 100
183
6' CEA-60101020101 100 CEA-60102020101 100 CEA-60103020101 50
9' CEA-60101030101 50 CEA-60102030101 50 CEA-60103030101 50
12' CEA-60101040101 50 CEA-60102040101 50 CEA-60103040101 50
15' CEA-60101050101 50 CEA-60102050101 50 CEA-60103050101 50
WEDGY - D01 18' CEA-60101060101 50 CEA-60102060101 50 CEA-60103060101 25
3' CEA-60102010102 25
173
CEA-60103010102 25
173
6' CEA-60102020102 25 CEA-60103020102 25
9' CEA-60102030102 25 CEA-60103030102 25
12' CEA-60102040102 25 CEA-60103040102 25
15' CEA-60102050102 25 CEA-60103050102 25
DSCL2 or 3 - D02 18' CEA-60102060102 25 CEA-60103060102 25
3' CEA-60102010103 25
104
CEA-60103010103 25
104
6' CEA-60102020103 25 CEA-60103020103 25
9' CEA-60102030103 25 CEA-60103030103 25
12' CEA-60102040103 25 CEA-60103040103 25
15' CEA-60102050103 25 CEA-60103050103 25
DSCU2 or 3 - D03 18' CEA-60102060103 25 CEA-60103060103 25
3' CEA-60101010104 25
77
CEA-60102010104 25 Upper Attach CEA-60103010104 25 Upper Attach
6' CEA-60101020104 25 CEA-60102020104 25104
CEA-60103020104 25104
9' CEA-60101030104 25 CEA-60102030104 25 CEA-60103030104 25
12' CEA-60101040104 25 CEA-60102040104 25 Lower Attach CEA-60103040104 25 Lower Attach
15' CEA-60101050104 25 CEA-60102050104 25173
CEA-60103050104 25173
WEDGY & DSC - D04 18' CEA-60101060104 25 CEA-60102060104 25 CEA-60103060104 25
3' CEA-60102010105 100
163
CEA-60103010105 100
183
6' CEA-60102020105 100 CEA-60103020105 50
9' CEA-60102030105 50 CEA-60103030105 50
12' CEA-60102040105 50 CEA-60103040105 50
15' CEA-60102050105 50 CEA-60103050105 50
SWP2 or 3 - D05 18' CEA-60102060105 50 CEA-60103060105 25
A t t a c h m e n t P a r t N u m b e r s
FIG
60
1
Part Numbers
Wedgy with 90° Tapcon Concrete Screw Anchor
Fig 601
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 11.• Capacities Shown in the table below account for the connection to the structure with a 1/4”x 2-1/4” Tapcon with 2” embedment into 3,000 PSI NWC. Acceptable for use in Cracked Concrete.• C02 = 3/8” x 3” Tapcon for heavier applications. Contact CEAS for revised assembly capacities.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Example:CEA-60102030101
A02 = No. 2 CableB03 = 9’ CableC01 = 601-1 - 1/4” x 2-1/4” Tapcon Concrete Screw Anchor (See Page 11)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
17
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-60201010101 100
77
CEA-60202010101 100
158
CEA-60203010101 100
314
6' CEA-60201020101 100 CEA-60202020101 100 CEA-60203020101 50
9' CEA-60201030101 50 CEA-60202030101 50 CEA-60203030101 50
12' CEA-60201040101 50 CEA-60202040101 50 CEA-60203040101 50
15' CEA-60201050101 50 CEA-60202050101 50 CEA-60203050101 50
WEDGY - D01 18' CEA-60201060101 50 CEA-60202060101 50 CEA-60203060101 25
3' CEA-60202010102 25
173
CEA-60203010102 25
173
6' CEA-60202020102 25 CEA-60203020102 25
9' CEA-60202030102 25 CEA-60203030102 25
12' CEA-60202040102 25 CEA-60203040102 25
15' CEA-60202050102 25 CEA-60203050102 25
DSCL2 or 3 - D02 18' CEA-60202060102 25 CEA-60203060102 25
3' CEA-60202010103 25
104
CEA-60203010103 25
104
6' CEA-60202020103 25 CEA-60203020103 25
9' CEA-60202030103 25 CEA-60203030103 25
12' CEA-60202040103 25 CEA-60203040103 25
15' CEA-60202050103 25 CEA-60203050103 25
DSCU2 or 3 - D03 18' CEA-60202060103 25 CEA-60203060103 25
3' CEA-60201010104 25
77
CEA-60202010104 25 Upper Attach CEA-60203010104 25 Upper Attach
6' CEA-60201020104 25 CEA-60202020104 25104
CEA-60203020104 25104
9' CEA-60201030104 25 CEA-60202030104 25 CEA-60203030104 25
12' CEA-60201040104 25 CEA-60202040104 25 Lower Attach CEA-60203040104 25 Lower Attach
15' CEA-60201050104 25 CEA-60202050104 25173
CEA-60203050104 25173
WEDGY & DSC - D04 18' CEA-60201060104 25 CEA-60202060104 25 CEA-60203060104 25
3' CEA-60202010105 100
163
CEA-60203010105 100
289
6' CEA-60202020105 100 CEA-60203020105 50
9' CEA-60202030105 50 CEA-60203030105 50
12' CEA-60202040105 50 CEA-60203040105 50
15' CEA-60202050105 50 CEA-60203050105 50
SWP2 or 3 - D05 18' CEA-60202060105 50 CEA-60203060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
60
2
Part Numbers
Wedgy with 90° Wedge Anchor
Fig 602
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 11.• Capacities Shown in the table below account for the connection to the structure with a 1/4”x 3-1/4” Wedge Anchor with 1-1/2” embedment into 3,000 PSI NWC or LWC. Not for use in cracked concrete applications. • For Cracked Concrete Applications use a C02 = 3/8” x 3” Wedge Anchor. Contact CEAS for revised assembly capacities.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Example:CEA-60202030101
A02 = No. 2 CableB03 = 9’ CableC01 = 602-1 - 1/4” x 3-1/4” Wedge Anchor (See Page 11)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
18
A t t a c h m e n t P a r t N u m b e r s
FIG
60
3
Part Numbers
Wedgy with 45° Tapcon Concrete Screw Anchor
Fig 603
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 11 .• Capacities Shown in the table below account for the connection to the structure with a 1/4”x 2-1/4” Tapcon with 2” embedment into 3,000 PSI NWC. Acceptable for use in Cracked Concrete.• C02 = 3/8” x 3” Tapcon for heavier applications. Contact CEAS for revised assembly capacities.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Example:CEA-60302030101
A02 = No. 2 CableB03 = 9’ CableC01 = 603-1 - 1/4” x 2-1/4” Tapcon Concrete Screw Anchor. (See Page 11)D01 = Wedgy Device
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-60301010101 100
77
CEA-60302010101 100
144
CEA-60303010101 100
144
6' CEA-60301020101 100 CEA-60302020101 100 CEA-60303020101 50
9' CEA-60301030101 50 CEA-60302030101 50 CEA-60303030101 50
12' CEA-60301040101 50 CEA-60302040101 50 CEA-60303040101 50
15' CEA-60301050101 50 CEA-60302050101 50 CEA-60303050101 50
WEDGY - D01 18' CEA-60301060101 50 CEA-60302060101 50 CEA-60303060101 25
3' CEA-60302010102 25
144
CEA-60303010102 25
144
6' CEA-60302020102 25 CEA-60303020102 25
9' CEA-60302030102 25 CEA-60303030102 25
12' CEA-60302040102 25 CEA-60303040102 25
15' CEA-60302050102 25 CEA-60303050102 25
DSCL2 or 3 - D02 18' CEA-60302060102 25 CEA-60303060102 25
3' CEA-60302010103 25
104
CEA-60303010103 25
104
6' CEA-60302020103 25 CEA-60303020103 25
9' CEA-60302030103 25 CEA-60303030103 25
12' CEA-60302040103 25 CEA-60303040103 25
15' CEA-60302050103 25 CEA-60303050103 25
DSCU2 or 3 - D03 18' CEA-60302060103 25 CEA-60303060103 25
3' CEA-60301010104 25
77
CEA-60302010104 25 Upper Attach CEA-60303010104 25 Upper Attach
6' CEA-60301020104 25 CEA-60302020104 25104
CEA-60303020104 25104
9' CEA-60301030104 25 CEA-60302030104 25 CEA-60303030104 25
12' CEA-60301040104 25 CEA-60302040104 25 Lower Attach CEA-60303040104 25 Lower Attach
15' CEA-60301050104 25 CEA-60302050104 25144
CEA-60303050104 25144
WEDGY & DSC - D04 18' CEA-60301060104 25 CEA-60302060104 25 CEA-60303060104 25
3' CEA-60302010105 100
144
CEA-60303010105 100
144
6' CEA-60302020105 100 CEA-60303020105 50
9' CEA-60302030105 50 CEA-60303030105 50
12' CEA-60302040105 50 CEA-60303040105 50
15' CEA-60302050105 50 CEA-60303050105 50
SWP2 or 3 - D05 18' CEA-60302060105 50 CEA-60303060105 25
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
19
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
60
4
Part Numbers
Wedgy with 45° Wedge Anchor
Fig 604
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 11.• Capacities Shown in the table below account for the connection to the structure with a 1/4”x 3-1/4” Wedge Anchor with 1-1/2” embedment into 3,000 PSI NWC or LWC. Not for use in cracked concrete applications. • For Cracked Concrete Applications use a C02 = 3/8” x 3” Wedge Anchor. Contact CEAS for revised assembly capacities.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Example:CEA-60402030101
A02 = No. 2 CableB03 = 9’ CableC01 = 604-1 - 1/4” x 3-1/4” Wedge Anchor. (See Page 11)D01 = Wedgy Device
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-60401010101 100
77
CEA-60402010101 100
158
CEA-60403010101 100
314
6' CEA-60401020101 100 CEA-60402020101 100 CEA-60403020101 50
9' CEA-60401030101 50 CEA-60402030101 50 CEA-60403030101 50
12' CEA-60401040101 50 CEA-60402040101 50 CEA-60403040101 50
15' CEA-60401050101 50 CEA-60402050101 50 CEA-60403050101 50
WEDGY - D01 18' CEA-60401060101 50 CEA-60402060101 50 CEA-60403060101 25
3' CEA-60402010102 25
173
CEA-60403010102 25
173
6' CEA-60402020102 25 CEA-60403020102 25
9' CEA-60402030102 25 CEA-60403030102 25
12' CEA-60402040102 25 CEA-60403040102 25
15' CEA-60402050102 25 CEA-60403050102 25
DSCL2 or 3 - D02 18' CEA-60402060102 25 CEA-60403060102 25
3' CEA-60402010103 25
104
CEA-60403010103 25
104
6' CEA-60402020103 25 CEA-60403020103 25
9' CEA-60402030103 25 CEA-60403030103 25
12' CEA-60402040103 25 CEA-60403040103 25
15' CEA-60402050103 25 CEA-60403050103 25
DSCU2 or 3 - D03 18' CEA-60402060103 25 CEA-60403060103 25
3' CEA-60401010104 25
77
CEA-60402010104 25 Upper Attach CEA-60403010104 25 Upper Attach
6' CEA-60401020104 25 CEA-60402020104 25104
CEA-60403020104 25104
9' CEA-60401030104 25 CEA-60402030104 25 CEA-60403030104 25
12' CEA-60401040104 25 CEA-60402040104 25 Lower Attach CEA-60403040104 25 Lower Attach
15' CEA-60401050104 25 CEA-60402050104 25173
CEA-60403050104 25173
WEDGY & DSC - D04 18' CEA-60401060104 25 CEA-60402060104 25 CEA-60403060104 25
3' CEA-60402010105 100
163
CEA-60403010105 100
289
6' CEA-60402020105 100 CEA-60403020105 50
9' CEA-60402030105 50 CEA-60403030105 50
12' CEA-60402040105 50 CEA-60403040105 50
15' CEA-60402050105 50 CEA-60403050105 50
SWP2 or 3 - D05 18' CEA-60402060105 50 CEA-60403060105 25
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
20
A t t a c h m e n t P a r t N u m b e r s
FIG
60
5
Part Numbers
Wedgy Tie Wire Wedge Anchor
Fig 605
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 11.• Capacities Shown in the table below account for the connection to the structure with a 1/4” Tie Wire Wedge Anchor with 1-1/8” embedment into 3,000 PSI NWC. Not for use in cracked concrete applications. • Capacities shown were derived from a legacy report based on the 2000 IBC.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Page63
Example:CEA-60502030101
A02 = No. 2 CableB03 = 9’ CableC01 = 605 - Tie Wire Wedge Anchor. (See Page 11)D01 = Wedgy Device
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-60501010101 100
77
CEA-60502010101 100
155
CEA-60403010101 100
155
6' CEA-60501020101 100 CEA-60502020101 100 CEA-60403020101 50
9' CEA-60501030101 50 CEA-60502030101 50 CEA-60403030101 50
12' CEA-60501040101 50 CEA-60502040101 50 CEA-60403040101 50
15' CEA-60501050101 50 CEA-60502050101 50 CEA-60403050101 50
WEDGY - D01 18' CEA-60501060101 50 CEA-60502060101 50 CEA-60403060101 25
3' CEA-60502010102 25
155
CEA-60403010102 25
155
6' CEA-60502020102 25 CEA-60403020102 25
9' CEA-60502030102 25 CEA-60403030102 25
12' CEA-60502040102 25 CEA-60403040102 25
15' CEA-60502050102 25 CEA-60403050102 25
DSCL2 or 3 - D02 18' CEA-60502060102 25 CEA-60403060102 25
3' CEA-60502010103 25
104
CEA-60403010103 25
104
6' CEA-60502020103 25 CEA-60403020103 25
9' CEA-60502030103 25 CEA-60403030103 25
12' CEA-60502040103 25 CEA-60403040103 25
15' CEA-60502050103 25 CEA-60403050103 25
DSCU2 or 3 - D03 18' CEA-60502060103 25 CEA-60403060103 25
3' CEA-60501010104 25
77
CEA-60502010104 25 Upper Attach CEA-60403010104 25 Upper Attach
6' CEA-60501020104 25 CEA-60502020104 25104
CEA-60403020104 25104
9' CEA-60501030104 25 CEA-60502030104 25 CEA-60403030104 25
12' CEA-60501040104 25 CEA-60502040104 25 Lower Attach CEA-60403040104 25 Lower Attach
15' CEA-60501050104 25 CEA-60502050104 25155
CEA-60403050104 25155
WEDGY & DSC - D04 18' CEA-60501060104 25 CEA-60502060104 25 CEA-60403060104 25
3' CEA-60502010105 100
155
CEA-60403010105 100
155
6' CEA-60502020105 100 CEA-60403020105 50
9' CEA-60502030105 50 CEA-60403030105 50
12' CEA-60502040105 50 CEA-60403040105 50
15' CEA-60502050105 50 CEA-60403050105 50
SWP2 or 3 - D05 18' CEA-60502060105 50 CEA-60403060105 25
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
21
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-60601010101 100
77
CEA-60602010101 100
150
CEA-60603010101 100
150
6' CEA-60601020101 100 CEA-60602020101 100 CEA-60603020101 50
9' CEA-60601030101 50 CEA-60602030101 50 CEA-60603030101 50
12' CEA-60601040101 50 CEA-60602040101 50 CEA-60603040101 50
15' CEA-60601050101 50 CEA-60602050101 50 CEA-60603050101 50
WEDGY - D01 18' CEA-60601060101 50 CEA-60602060101 50 CEA-60603060101 25
3' CEA-60602010102 25
150
CEA-60603010102 25
150
6' CEA-60602020102 25 CEA-60603020102 25
9' CEA-60602030102 25 CEA-60603030102 25
12' CEA-60602040102 25 CEA-60603040102 25
15' CEA-60602050102 25 CEA-60603050102 25
DSCL2 or 3 - D02 18' CEA-60602060102 25 CEA-60603060102 25
3' CEA-60602010103 25
104
CEA-60603010103 25
104
6' CEA-60602020103 25 CEA-60603020103 25
9' CEA-60602030103 25 CEA-60603030103 25
12' CEA-60602040103 25 CEA-60603040103 25
15' CEA-60602050103 25 CEA-60603050103 25
DSCU2 or 3 - D03 18' CEA-60602060103 25 CEA-60603060103 25
3' CEA-60601010104 25
77
CEA-60602010104 25 Upper Attach CEA-60603010104 25 Upper Attach
6' CEA-60601020104 25 CEA-60602020104 25104
CEA-60603020104 25104
9' CEA-60601030104 25 CEA-60602030104 25 CEA-60603030104 25
12' CEA-60601040104 25 CEA-60602040104 25 Lower Attach CEA-60603040104 25 Lower Attach
15' CEA-60601050104 25 CEA-60602050104 25150
CEA-60603050104 25150
WEDGY & DSC - D04 18' CEA-60601060104 25 CEA-60602060104 25 CEA-60603060104 25
3' CEA-60602010105 100
150
CEA-60603010105 100
150
6' CEA-60602020105 100 CEA-60603020105 50
9' CEA-60602030105 50 CEA-60603030105 50
12' CEA-60602040105 50 CEA-60603040105 50
15' CEA-60602050105 50 CEA-60603050105 50
SWP2 or 3 - D05 18' CEA-60602060105 50 CEA-60603060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
60
6
Part Numbers
Wedgy Tie Wire Spike Anchor
Fig 606
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 11.• Capacities Shown in the table below account for the connection to the structure with a 1/4” Tie Wire Spike Anchor with 1-1/4” embedment into 3,000 PSI NWC. Not for use in cracked concrete applications. • Capacities shown were derived from a legacy report based on the 2000 IBC.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Page63
Example:CEA-60602030101
A02 = No. 2 CableB03 = 9’ CableC01 = 606 - Tie Wire Spike Anchor. (See Page 11)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
22
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-62001010101 100
77
CEA-62002010101 100
158
CEA-62003010101 100
314
6' CEA-62001020101 100 CEA-62002020101 100 CEA-62003020101 50
9' CEA-62001030101 50 CEA-62002030101 50 CEA-62003030101 50
12' CEA-62001040101 50 CEA-62002040101 50 CEA-62003040101 50
15' CEA-62001050101 50 CEA-62002050101 50 CEA-62003050101 50
WEDGY - D01 18' CEA-62001060101 50 CEA-62002060101 50 CEA-62003060101 25
3' CEA-62002010102 25
173
CEA-62003010102 25
173
6' CEA-62002020102 25 CEA-62003020102 25
9' CEA-62002030102 25 CEA-62003030102 25
12' CEA-62002040102 25 CEA-62003040102 25
15' CEA-62002050102 25 CEA-62003050102 25
DSCL2 or 3 - D02 18' CEA-62002060102 25 CEA-62003060102 25
3' CEA-62002010103 25
104
CEA-62003010103 25
104
6' CEA-62002020103 25 CEA-62003020103 25
9' CEA-62002030103 25 CEA-62003030103 25
12' CEA-62002040103 25 CEA-62003040103 25
15' CEA-62002050103 25 CEA-62003050103 25
DSCU2 or 3 - D03 18' CEA-62002060103 25 CEA-62003060103 25
3' CEA-62001010104 25
77
CEA-62002010104 25 Upper Attach CEA-62003010104 25 Upper Attach
6' CEA-62001020104 25 CEA-62002020104 25104
CEA-62003020104 25104
9' CEA-62001030104 25 CEA-62002030104 25 CEA-62003030104 25
12' CEA-62001040104 25 CEA-62002040104 25 Lower Attach CEA-62003040104 25 Lower Attach
15' CEA-62001050104 25 CEA-62002050104 25173
CEA-62003050104 25173
WEDGY & DSC - D04 18' CEA-62001060104 25 CEA-62002060104 25 CEA-62003060104 25
3' CEA-62002010105 100
163
CEA-62003010105 100
223
6' CEA-62002020105 100 CEA-62003020105 50
9' CEA-62002030105 50 CEA-62003030105 50
12' CEA-62002040105 50 CEA-62003040105 50
15' CEA-62002050105 50 CEA-62003050105 50
SWP2 or 3 - D05 18' CEA-62002060105 50 CEA-62003060105 25
A t t a c h m e n t P a r t N u m b e r sSTEELMETAL
Part Numbers
Wedgy With Loop
Fig 620
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 12.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
FIG
62
0
Example:CEA-62002030101
A02 = No. 2 CableB03 = 9’ CableC01 = 620 - Loop Connection. (See Page 12)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
23
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 12.• Capacities Shown in the table below account for the connection to 20g metal deck with no concrete with a 3/4” (2” OAL) Eyelag Screw.• Specify C02 to order a 2” (3-1/4” OAL) Eyelag Screw.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-62101010101 100
77
CEA-62102010101 100
125
CEA-62103010101 100
125
6' CEA-62101020101 100 CEA-62102020101 100 CEA-62103020101 50
9' CEA-62101030101 50 CEA-62102030101 50 CEA-62103030101 50
12' CEA-62101040101 50 CEA-62102040101 50 CEA-62103040101 50
15' CEA-62101050101 50 CEA-62102050101 50 CEA-62103050101 50
WEDGY - D01 18' CEA-62101060101 50 CEA-62102060101 50 CEA-62103060101 25
3' CEA-62102010102 25
125
CEA-62103010102 25
125
6' CEA-62102020102 25 CEA-62103020102 25
9' CEA-62102030102 25 CEA-62103030102 25
12' CEA-62102040102 25 CEA-62103040102 25
15' CEA-62102050102 25 CEA-62103050102 25
DSCL2 or 3 - D02 18' CEA-62102060102 25 CEA-62103060102 25
3' CEA-62102010103 25
104
CEA-62103010103 25
104
6' CEA-62102020103 25 CEA-62103020103 25
9' CEA-62102030103 25 CEA-62103030103 25
12' CEA-62102040103 25 CEA-62103040103 25
15' CEA-62102050103 25 CEA-62103050103 25
DSCU2 or 3 - D03 18' CEA-62102060103 25 CEA-62103060103 25
3' CEA-62101010104 25
77
CEA-62102010104 25 Upper Attach CEA-62103010104 25 Upper Attach
6' CEA-62101020104 25 CEA-62102020104 25104
CEA-62103020104 25104
9' CEA-62101030104 25 CEA-62102030104 25 CEA-62103030104 25
12' CEA-62101040104 25 CEA-62102040104 25 Lower Attach CEA-62103040104 25 Lower Attach
15' CEA-62101050104 25 CEA-62102050104 25125
CEA-62103050104 25125
WEDGY & DSC - D04 18' CEA-62101060104 25 CEA-62102060104 25 CEA-62103060104 25
3' CEA-62102010105 100
125
CEA-62103010105 100
125
6' CEA-62102020105 100 CEA-62103020105 50
9' CEA-62102030105 50 CEA-62103030105 50
12' CEA-62102040105 50 CEA-62103040105 50
15' CEA-62102050105 50 CEA-62103050105 50
SWP2 or 3 - D05 18' CEA-62102060105 50 CEA-62103060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
62
1STEELMETAL
CEAS Eyewire Pole Tool
Part Numbers
Wedgy with Metal Eyecable
Fig 621Metal Deck
Example:CEA-62102030101
A02 = No. 2 CableB03 = 9’ CableC01 = 621-1 - Metal Eyelag - 1/4” x 3/4” (2” OAL). (See Page 12)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
24
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-62201010101 100
77
CEA-62202010101 100
158
CEA-62203010101 100
300
6' CEA-62201020101 100 CEA-62202020101 100 CEA-62203020101 50
9' CEA-62201030101 50 CEA-62202030101 50 CEA-62203030101 50
12' CEA-62201040101 50 CEA-62202040101 50 CEA-62203040101 50
15' CEA-62201050101 50 CEA-62202050101 50 CEA-62203050101 50
WEDGY - D01 18' CEA-62201060101 50 CEA-62202060101 50 CEA-62203060101 25
3' CEA-62202010102 25
173
CEA-62203010102 25
173
6' CEA-62202020102 25 CEA-62203020102 25
9' CEA-62202030102 25 CEA-62203030102 25
12' CEA-62202040102 25 CEA-62203040102 25
15' CEA-62202050102 25 CEA-62203050102 25
DSCL2 or 3 - D02 18' CEA-62202060102 25 CEA-62203060102 25
3' CEA-62202010103 25
104
CEA-62203010103 25
104
6' CEA-62202020103 25 CEA-62203020103 25
9' CEA-62202030103 25 CEA-62203030103 25
12' CEA-62202040103 25 CEA-62203040103 25
15' CEA-62202050103 25 CEA-62203050103 25
DSCU2 or 3 - D03 18' CEA-62202060103 25 CEA-62203060103 25
3' CEA-62201010104 25
77
CEA-62202010104 25 Upper Attach CEA-62203010104 25 Upper Attach
6' CEA-62201020104 25 CEA-62202020104 25104
CEA-62203020104 25104
9' CEA-62201030104 25 CEA-62202030104 25 CEA-62203030104 25
12' CEA-62201040104 25 CEA-62202040104 25 Lower Attach CEA-62203040104 25 Lower Attach
15' CEA-62201050104 25 CEA-62202050104 25173
CEA-62203050104 25173
WEDGY & DSC - D04 18' CEA-62201060104 25 CEA-62202060104 25 CEA-62203060104 25
3' CEA-62202010105 100
163
CEA-62203010105 100
223
6' CEA-62202020105 100 CEA-62203020105 50
9' CEA-62202030105 50 CEA-62203030105 50
12' CEA-62202040105 50 CEA-62203040105 50
15' CEA-62202050105 50 CEA-62203050105 50
SWP2 or 3 - D05 18' CEA-62202060105 50 CEA-62203060105 25
A t t a c h m e n t P a r t N u m b e r s
FIG
62
2STEELMETAL
Part Numbers
Wedgy with Bar Joist Pull-down Clamp
Fig 622
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to Angle Iron in a vertical application• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Example:CEA-62202030101
A02 = No. 2 CableB03 = 9’ CableC01 = 622 - Stiffy Bar Joist Pull-down Clamp. (See Page 12)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
25
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-62301010101 50
77
CEA-62302010101 50
158
CEA-62303010101 50
200
6' CEA-62301020101 50 CEA-62302020101 25 CEA-62303020101 25
9' CEA-62301030101 25 CEA-62302030101 25 CEA-62303030101 25
12' CEA-62301040101 25 CEA-62302040101 25 CEA-62303040101 25
15' CEA-62301050101 25 CEA-62302050101 25 CEA-62303050101 25
WEDGY - D01 18' CEA-62301060101 25 CEA-62302060101 25 CEA-62303060101 25
3' CEA-62302010102 20
173
CEA-62303010102 20
173
6' CEA-62302020102 20 CEA-62303020102 20
9' CEA-62302030102 20 CEA-62303030102 20
12' CEA-62302040102 20 CEA-62303040102 20
15' CEA-62302050102 20 CEA-62303050102 20
DSCL2 or 3 - D02 18' CEA-62302060102 20 CEA-62303060102 20
3' CEA-62302010103 20
104
CEA-62303010103 20
104
6' CEA-62302020103 20 CEA-62303020103 20
9' CEA-62302030103 20 CEA-62303030103 20
12' CEA-62302040103 20 CEA-62303040103 20
15' CEA-62302050103 20 CEA-62303050103 20
DSCU2 or 3 - D03 18' CEA-62302060103 20 CEA-62303060103 20
3' CEA-62301010104 25
77
CEA-62302010104 20 Upper Attach CEA-62303010104 20 Upper Attach
6' CEA-62301020104 25 CEA-62302020104 20104
CEA-62303020104 20104
9' CEA-62301030104 25 CEA-62302030104 20 CEA-62303030104 20
12' CEA-62301040104 25 CEA-62302040104 20 Lower Attach CEA-62303040104 20 Lower Attach
15' CEA-62301050104 25 CEA-62302050104 20173
CEA-62303050104 20173
WEDGY & DSC - D04 18' CEA-62301060104 25 CEA-62302060104 20 CEA-62303060104 20
3' CEA-62302010105 50
163
CEA-62303010105 50
200
6' CEA-62302020105 25 CEA-62303020105 25
9' CEA-62302030105 25 CEA-62303030105 25
12' CEA-62302040105 25 CEA-62303040105 25
15' CEA-62302050105 25 CEA-62303050105 25
SWP2 or 3 - D05 18' CEA-62302060105 25 CEA-62303060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
62
3STEELMETAL
Part Numbers
Wedgy with Hammer-on Beam Clamp
Fig 623
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to Angle Iron in a vertical application.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Example:CEA-62302030101
A02 = No. 2 CableB03 = 9’ CableC01 = 623 - Stiffy Hammer-on Beam Clamp. (See Page 12)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
26
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-62401010101 100
77
CEA-62402010101 100
104
CEA-62403010101 100
104
6' CEA-62401020101 100 CEA-62402020101 100 CEA-62403020101 50
9' CEA-62401030101 50 CEA-62402030101 50 CEA-62403030101 50
12' CEA-62401040101 50 CEA-62402040101 50 CEA-62403040101 50
15' CEA-62401050101 50 CEA-62402050101 50 CEA-62403050101 50
WEDGY - D01 18' CEA-62401060101 50 CEA-62402060101 50 CEA-62403060101 25
3' CEA-62402010102 25
104
CEA-62403010102 25
104
6' CEA-62402020102 25 CEA-62403020102 25
9' CEA-62402030102 25 CEA-62403030102 25
12' CEA-62402040102 25 CEA-62403040102 25
15' CEA-62402050102 25 CEA-62403050102 25
DSCL2 or 3 - D02 18' CEA-62402060102 25 CEA-62403060102 25
3' CEA-62402010103 25
104
CEA-62403010103 25
104
6' CEA-62402020103 25 CEA-62403020103 25
9' CEA-62402030103 25 CEA-62403030103 25
12' CEA-62402040103 25 CEA-62403040103 25
15' CEA-62402050103 25 CEA-62403050103 25
DSCU2 or 3 - D03 18' CEA-62402060103 25 CEA-62403060103 25
3' CEA-62401010104 25
77
CEA-62402010104 25 Upper Attach CEA-62403010104 25 Upper Attach
6' CEA-62401020104 25 CEA-62402020104 25104
CEA-62403020104 25104
9' CEA-62401030104 25 CEA-62402030104 25 CEA-62403030104 25
12' CEA-62401040104 25 CEA-62402040104 25 Lower Attach CEA-62403040104 25 Lower Attach
15' CEA-62401050104 25 CEA-62402050104 25104
CEA-62403050104 25104
WEDGY & DSC - D04 18' CEA-62401060104 25 CEA-62402060104 25 CEA-62403060104 25
3' CEA-62402010105 100
104
CEA-62403010105 100
104
6' CEA-62402020105 100 CEA-62403020105 50
9' CEA-62402030105 50 CEA-62403030105 50
12' CEA-62402040105 50 CEA-62403040105 50
15' CEA-62402050105 50 CEA-62403050105 50
SWP2 or 3 - D05 18' CEA-62402060105 50 CEA-62403060105 25
A t t a c h m e n t P a r t N u m b e r s
FIG
62
4STEELMETAL
Metal Deck
Part Numbers
AB 90° Clip with #10 Screw
Fig 624
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 12.• Capacities Shown in the table below account for the connection of a #10 Self Drilling Screw into 20g metal deck with no concrete• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Example:CEA-62402030101
A02 = No. 2 CableB03 = 9’ CableC01 = 624-1 - AB90 - #10 X 1-1/4” HWH Self Driller. (See Page 12)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
27
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-62501010101 100
77
CEA-62502010101 100
99
CEA-62503010101 100
99
6' CEA-62501020101 100 CEA-62502020101 100 CEA-62503020101 50
9' CEA-62501030101 50 CEA-62502030101 50 CEA-62503030101 50
12' CEA-62501040101 50 CEA-62502040101 50 CEA-62503040101 50
15' CEA-62501050101 50 CEA-62502050101 50 CEA-62503050101 50
WEDGY - D01 18' CEA-62501060101 50 CEA-62502060101 50 CEA-62503060101 25
3' CEA-62502010102 25
99
CEA-62503010102 25
99
6' CEA-62502020102 25 CEA-62503020102 25
9' CEA-62502030102 25 CEA-62503030102 25
12' CEA-62502040102 25 CEA-62503040102 25
15' CEA-62502050102 25 CEA-62503050102 25
DSCL2 or 3 - D02 18' CEA-62502060102 25 CEA-62503060102 25
3' CEA-62502010103 25
99
CEA-62503010103 25
99
6' CEA-62502020103 25 CEA-62503020103 25
9' CEA-62502030103 25 CEA-62503030103 25
12' CEA-62502040103 25 CEA-62503040103 25
15' CEA-62502050103 25 CEA-62503050103 25
DSCU2 or 3 - D03 18' CEA-62502060103 25 CEA-62503060103 25
3' CEA-62501010104 25
77
CEA-62502010104 25 Upper Attach CEA-62503010104 25 Upper Attach
6' CEA-62501020104 25 CEA-62502020104 2599
CEA-62503020104 2599
9' CEA-62501030104 25 CEA-62502030104 25 CEA-62503030104 25
12' CEA-62501040104 25 CEA-62502040104 25 Lower Attach CEA-62503040104 25 Lower Attach
15' CEA-62501050104 25 CEA-62502050104 2599
CEA-62503050104 2599
WEDGY & DSC - D04 18' CEA-62501060104 25 CEA-62502060104 25 CEA-62503060104 25
3' CEA-62502010105 100
99
CEA-62503010105 100
99
6' CEA-62502020105 100 CEA-62503020105 50
9' CEA-62502030105 50 CEA-62503030105 50
12' CEA-62502040105 50 CEA-62503040105 50
15' CEA-62502050105 50 CEA-62503050105 50
SWP2 or 3 - D05 18' CEA-62502060105 50 CEA-62503060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
62
5
Metal Deck
Part Numbers
AB 45° Clip with #10 Screw
Fig 625
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 12.• Capacities Shown in the table below account for the connection of a #10 Self Drilling Screw into 20g metal deck with no concrete.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
STEELMETAL
Example:CEA-62502030101
A02 = No. 2 CableB03 = 9’ CableC01 = 625-1 - AB45 - #10 X 1-1/4” HWH Self Driller. (See Page 12)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
28
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-62601010101 50
77
CEA-62602010101 50
158
CEA-62603010101 50
207
6' CEA-62601020101 50 CEA-62602020101 25 CEA-62603020101 25
9' CEA-62601030101 25 CEA-62602030101 25 CEA-62603030101 25
12' CEA-62601040101 25 CEA-62602040101 25 CEA-62603040101 25
15' CEA-62601050101 25 CEA-62602050101 25 CEA-62603050101 25
WEDGY - D01 18' CEA-62601060101 25 CEA-62602060101 25 CEA-62603060101 25
3' CEA-62602010102 20
173
CEA-62603010102 20
173
6' CEA-62602020102 20 CEA-62603020102 20
9' CEA-62602030102 20 CEA-62603030102 20
12' CEA-62602040102 20 CEA-62603040102 20
15' CEA-62602050102 20 CEA-62603050102 20
DSCL2 or 3 - D02 18' CEA-62602060102 20 CEA-62603060102 20
3' CEA-62602010103 20
104
CEA-62603010103 20
104
6' CEA-62602020103 20 CEA-62603020103 20
9' CEA-62602030103 20 CEA-62603030103 20
12' CEA-62602040103 20 CEA-62603040103 20
15' CEA-62602050103 20 CEA-62603050103 20
DSCU2 or 3 - D03 18' CEA-62602060103 20 CEA-62603060103 20
3' CEA-62601010104 25
77
CEA-62602010104 20 Upper Attach CEA-62603010104 20 Upper Attach
6' CEA-62601020104 25 CEA-62602020104 20104
CEA-62603020104 20104
9' CEA-62601030104 25 CEA-62602030104 20 CEA-62603030104 20
12' CEA-62601040104 25 CEA-62602040104 20 Lower Attach CEA-62603040104 20 Lower Attach
15' CEA-62601050104 25 CEA-62602050104 20173
CEA-62603050104 20173
WEDGY & DSC - D04 18' CEA-62601060104 25 CEA-62602060104 20 CEA-62603060104 20
3' CEA-62602010105 50
163
CEA-62603010105 50
207
6' CEA-62602020105 25 CEA-62603020105 25
9' CEA-62602030105 25 CEA-62603030105 25
12' CEA-62602040105 25 CEA-62603040105 25
15' CEA-62602050105 25 CEA-62603050105 25
SWP2 or 3 - D05 18' CEA-62602060105 25 CEA-62603060105 25
A t t a c h m e n t P a r t N u m b e r s
FIG
62
6STEELMETAL
Part Numbers
Wedgy SP90° Clip with two #10 Screws
Fig 626
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 12.• Capacities Shown in the table below account for the connection of 2ea #10 Self Drilling Screws into 20g metal deck with no concrete.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Metal Deck
Example:CEA-62602030101
A02 = No. 2 CableB03 = 9’ CableC01 = 626-1 - SP90 - 2ea #10 X 1-1/4” HWH Self Drillers. (See Page 12)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
29
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-62701010101 50
77
CEA-62702010101 50
158
CEA-62703010101 50
198
6' CEA-62701020101 50 CEA-62702020101 25 CEA-62703020101 25
9' CEA-62701030101 25 CEA-62702030101 25 CEA-62703030101 25
12' CEA-62701040101 25 CEA-62702040101 25 CEA-62703040101 25
15' CEA-62701050101 25 CEA-62702050101 25 CEA-62703050101 25
WEDGY - D01 18' CEA-62701060101 25 CEA-62702060101 25 CEA-62703060101 25
3' CEA-62702010102 20
173
CEA-62703010102 20
173
6' CEA-62702020102 20 CEA-62703020102 20
9' CEA-62702030102 20 CEA-62703030102 20
12' CEA-62702040102 20 CEA-62703040102 20
15' CEA-62702050102 20 CEA-62703050102 20
DSCL2 or 3 - D02 18' CEA-62702060102 20 CEA-62703060102 20
3' CEA-62702010103 20
104
CEA-62703010103 20
104
6' CEA-62702020103 20 CEA-62703020103 20
9' CEA-62702030103 20 CEA-62703030103 20
12' CEA-62702040103 20 CEA-62703040103 20
15' CEA-62702050103 20 CEA-62703050103 20
DSCU2 or 3 - D03 18' CEA-62702060103 20 CEA-62703060103 20
3' CEA-62701010104 25
77
CEA-62702010104 20 Upper Attach CEA-62703010104 20 Upper Attach
6' CEA-62701020104 25 CEA-62702020104 20104
CEA-62703020104 20104
9' CEA-62701030104 25 CEA-62702030104 20 CEA-62703030104 20
12' CEA-62701040104 25 CEA-62702040104 20 Lower Attach CEA-62703040104 20 Lower Attach
15' CEA-62701050104 25 CEA-62702050104 20173
CEA-62703050104 20173
WEDGY & DSC - D04 18' CEA-62701060104 25 CEA-62702060104 20 CEA-62703060104 20
3' CEA-62702010105 50
163
CEA-62703010105 50
198
6' CEA-62702020105 25 CEA-62703020105 25
9' CEA-62702030105 25 CEA-62703030105 25
12' CEA-62702040105 25 CEA-62703040105 25
15' CEA-62702050105 25 CEA-62703050105 25
SWP2 or 3 - D05 18' CEA-62702060105 25 CEA-62703060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
62
7STEELMETAL
Part Numbers
Wedgy SP45° Clip with two #10 Screws
Fig 627
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 12.• Capacities Shown in the table below account for the connection of 2ea #10 Self Drilling Screws into 20g metal deck with no concrete.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Metal Deck
Example:CEA-62702030101
A02 = No. 2 CableB03 = 9’ CableC01 = 627-1 - SP45 - 2ea #10 X 1-1/4” HWH Self Drillers. (See Page 12)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
30
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-62801010101 100
77
CEA-62802010101 100
100
CEA-62803010101 100
100
6' CEA-62801020101 100 CEA-62802020101 100 CEA-62803020101 50
9' CEA-62801030101 50 CEA-62802030101 50 CEA-62803030101 50
12' CEA-62801040101 50 CEA-62802040101 50 CEA-62803040101 50
15' CEA-62801050101 50 CEA-62802050101 50 CEA-62803050101 50
WEDGY - D01 18' CEA-62801060101 50 CEA-62802060101 50 CEA-62803060101 25
3' CEA-62802010102 25
100
CEA-62803010102 25
100
6' CEA-62802020102 25 CEA-62803020102 25
9' CEA-62802030102 25 CEA-62803030102 25
12' CEA-62802040102 25 CEA-62803040102 25
15' CEA-62802050102 25 CEA-62803050102 25
DSCL2 or 3 - D02 18' CEA-62802060102 25 CEA-62803060102 25
3' CEA-62802010103 25
100
CEA-62803010103 25
100
6' CEA-62802020103 25 CEA-62803020103 25
9' CEA-62802030103 25 CEA-62803030103 25
12' CEA-62802040103 25 CEA-62803040103 25
15' CEA-62802050103 25 CEA-62803050103 25
DSCU2 or 3 - D03 18' CEA-62802060103 25 CEA-62803060103 25
3' CEA-62801010104 25
77
CEA-62802010104 25 Upper Attach CEA-62803010104 25 Upper Attach
6' CEA-62801020104 25 CEA-62802020104 25100
CEA-62803020104 25100
9' CEA-62801030104 25 CEA-62802030104 25 CEA-62803030104 25
12' CEA-62801040104 25 CEA-62802040104 25 Lower Attach CEA-62803040104 25 Lower Attach
15' CEA-62801050104 25 CEA-62802050104 25100
CEA-62803050104 25100
WEDGY & DSC - D04 18' CEA-62801060104 25 CEA-62802060104 25 CEA-62803060104 25
3' CEA-62802010105 100
100
CEA-62803010105 100
100
6' CEA-62802020105 100 CEA-62803020105 50
9' CEA-62802030105 50 CEA-62803030105 50
12' CEA-62802040105 50 CEA-62803040105 50
15' CEA-62802050105 50 CEA-62803050105 50
SWP2 or 3 - D05 18' CEA-62802060105 50 CEA-62803060105 25
Part Numbers
Wedgy With Snap Hook
Fig 628
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection the Snap Hook to a steel member or looped around itself.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
A t t a c h m e n t P a r t N u m b e r sSTEELMETAL
FIG
62
8
Designed to pass through 1/4” and larger holes.
Example:CEA-62802030101
A02 = No. 2 CableB03 = 9’ CableC01 = 628 - Snaphook. (See Page 12)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
31
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-64001010101 100
77
CEA-64002010101 100
158
CEA-64003010101 100
270
6' CEA-64001020101 100 CEA-64002020101 100 CEA-64003020101 50
9' CEA-64001030101 50 CEA-64002030101 50 CEA-64003030101 50
12' CEA-64001040101 50 CEA-64002040101 50 CEA-64003040101 50
15' CEA-64001050101 50 CEA-64002050101 50 CEA-64003050101 50
WEDGY - D01 18' CEA-64001060101 50 CEA-64002060101 50 CEA-64003060101 25
3' CEA-64002010102 25
173
CEA-64003010102 25
173
6' CEA-64002020102 25 CEA-64003020102 25
9' CEA-64002030102 25 CEA-64003030102 25
12' CEA-64002040102 25 CEA-64003040102 25
15' CEA-64002050102 25 CEA-64003050102 25
DSCL2 or 3 - D02 18' CEA-64002060102 25 CEA-64003060102 25
3' CEA-64002010103 25
104
CEA-64003010103 25
104
6' CEA-64002020103 25 CEA-64003020103 25
9' CEA-64002030103 25 CEA-64003030103 25
12' CEA-64002040103 25 CEA-64003040103 25
15' CEA-64002050103 25 CEA-64003050103 25
DSCU2 or 3 - D03 18' CEA-64002060103 25 CEA-64003060103 25
3' CEA-64001010104 25
77
CEA-64002010104 25 Upper Attach CEA-64003010104 25 Upper Attach
6' CEA-64001020104 25 CEA-64002020104 25104
CEA-64003020104 25104
9' CEA-64001030104 25 CEA-64002030104 25 CEA-64003030104 25
12' CEA-64001040104 25 CEA-64002040104 25 Lower Attach CEA-64003040104 25 Lower Attach
15' CEA-64001050104 25 CEA-64002050104 25173
CEA-64003050104 25173
WEDGY & DSC - D04 18' CEA-64001060104 25 CEA-64002060104 25 CEA-64003060104 25
3' CEA-64002010105 100
163
CEA-64003010105 100
223
6' CEA-64002020105 100 CEA-64003020105 50
9' CEA-64002030105 50 CEA-64003030105 50
12' CEA-64002040105 50 CEA-64003040105 50
15' CEA-64002050105 50 CEA-64003050105 50
SWP2 or 3 - D05 18' CEA-64002060105 50 CEA-64003060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
Wedgy with Wood Eyecable
Fig 640
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 13.• Capacities Shown in the table below account for the connection of a 1/4” Eye Lag into Douglas Fir or a Glulam.• Capacities shown were derived from a legacy report based on the 2000 IBC.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
FIG
64
0
Illustrations are not to scale
Example:CEA-64002030101
A02 = No. 2 CableB03 = 9’ CableC01 = 640-1 - Wood Eyelag - 1/4” x 3”. (See Page 13)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
CEAS Eyewire Pole Tool
32
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-64101010101 100
77
CEA-64102010101 100
100
CEA-64103010101 100
100
6' CEA-64101020101 100 CEA-64102020101 100 CEA-64103020101 50
9' CEA-64101030101 50 CEA-64102030101 50 CEA-64103030101 50
12' CEA-64101040101 50 CEA-64102040101 50 CEA-64103040101 50
15' CEA-64101050101 50 CEA-64102050101 50 CEA-64103050101 50
WEDGY - D01 18' CEA-64101060101 50 CEA-64102060101 50 CEA-64103060101 25
3' CEA-64102010102 25
100
CEA-64103010102 25
100
6' CEA-64102020102 25 CEA-64103020102 25
9' CEA-64102030102 25 CEA-64103030102 25
12' CEA-64102040102 25 CEA-64103040102 25
15' CEA-64102050102 25 CEA-64103050102 25
DSCL2 or 3 - D02 18' CEA-64102060102 25 CEA-64103060102 25
3' CEA-64102010103 25
100
CEA-64103010103 25
100
6' CEA-64102020103 25 CEA-64103020103 25
9' CEA-64102030103 25 CEA-64103030103 25
12' CEA-64102040103 25 CEA-64103040103 25
15' CEA-64102050103 25 CEA-64103050103 25
DSCU2 or 3 - D03 18' CEA-64102060103 25 CEA-64103060103 25
3' CEA-64101010104 25
77
CEA-64102010104 25 Upper Attach CEA-64103010104 25 Upper Attach
6' CEA-64101020104 25 CEA-64102020104 25100
CEA-64103020104 25100
9' CEA-64101030104 25 CEA-64102030104 25 CEA-64103030104 25
12' CEA-64101040104 25 CEA-64102040104 25 Lower Attach CEA-64103040104 25 Lower Attach
15' CEA-64101050104 25 CEA-64102050104 25100
CEA-64103050104 25100
WEDGY & DSC - D04 18' CEA-64101060104 25 CEA-64102060104 25 CEA-64103060104 25
3' CEA-64102010105 100
100
CEA-64103010105 100
100
6' CEA-64102020105 100 CEA-64103020105 50
9' CEA-64102030105 50 CEA-64103030105 50
12' CEA-64102040105 50 CEA-64103040105 50
15' CEA-64102050105 50 CEA-64103050105 50
SWP2 or 3 - D05 18' CEA-64102060105 50 CEA-64103060105 25
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
Wedgy with Timberpin
Fig 641
FIG
64
1
Illustrations are not to scale
CEAS Stiffy Toolwith Timberpin Nosepiece
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• The Timberpin is quickly installed with a Powder Actuated Tool.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Page67
Example:CEA-64102030101
A02 = No. 2 CableB03 = 9’ CableC01 = 641 - Timberpin and Clip - PDCTP250. (See Page 13)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
33
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-64201010101 50
77
CEA-64202010101 50
133
CEA-64203010101 50
133
6' CEA-64201020101 50 CEA-64202020101 25 CEA-64203020101 25
9' CEA-64201030101 25 CEA-64202030101 25 CEA-64203030101 25
12' CEA-64201040101 25 CEA-64202040101 25 CEA-64203040101 25
15' CEA-64201050101 25 CEA-64202050101 25 CEA-64203050101 25
WEDGY - D01 18' CEA-64201060101 25 CEA-64202060101 25 CEA-64203060101 25
3' CEA-64202010102 20
133
CEA-64203010102 20
133
6' CEA-64202020102 20 CEA-64203020102 20
9' CEA-64202030102 20 CEA-64203030102 20
12' CEA-64202040102 20 CEA-64203040102 20
15' CEA-64202050102 20 CEA-64203050102 20
DSCL2 or 3 - D02 18' CEA-64202060102 20 CEA-64203060102 20
3' CEA-64202010103 20
104
CEA-64203010103 20
104
6' CEA-64202020103 20 CEA-64203020103 20
9' CEA-64202030103 20 CEA-64203030103 20
12' CEA-64202040103 20 CEA-64203040103 20
15' CEA-64202050103 20 CEA-64203050103 20
DSCU2 or 3 - D03 18' CEA-64202060103 20 CEA-64203060103 20
3' CEA-64201010104 25
77
CEA-64202010104 20 Upper Attach CEA-64203010104 20 Upper Attach
6' CEA-64201020104 25 CEA-64202020104 20104
CEA-64203020104 20104
9' CEA-64201030104 25 CEA-64202030104 20 CEA-64203030104 20
12' CEA-64201040104 25 CEA-64202040104 20 Lower Attach CEA-64203040104 20 Lower Attach
15' CEA-64201050104 25 CEA-64202050104 20133
CEA-64203050104 20133
WEDGY & DSC - D04 18' CEA-64201060104 25 CEA-64202060104 20 CEA-64203060104 20
3' CEA-64202010105 50
133
CEA-64203010105 50
133
6' CEA-64202020105 25 CEA-64203020105 25
9' CEA-64202030105 25 CEA-64203030105 25
12' CEA-64202040105 25 CEA-64203040105 25
15' CEA-64202050105 25 CEA-64203050105 25
SWP2 or 3 - D05 18' CEA-64202060105 25 CEA-64203060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
Wedgy with Wood Pull-down Clamp
Fig 642
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 13.• Capacities Shown in the table below account for the connection to structure with the Wood Pull-down Clamp.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
FIG
64
2
Illustrations are not to scale
Example:CEA-6420B030101
A02 = No. 2 CableB03 = 9’ CableC01 = 642-1 - Stiffy Wood Pull Down Beam Clamp - Nom. 2” Lumber. (See Page 13)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
34
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-64301010101 100
77
CEA-64302010101 100
158
CEA-64303010101 100
216
6' CEA-64301020101 100 CEA-64302020101 100 CEA-64303020101 50
9' CEA-64301030101 50 CEA-64302030101 50 CEA-64303030101 50
12' CEA-64301040101 50 CEA-64302040101 50 CEA-64303040101 50
15' CEA-64301050101 50 CEA-64302050101 50 CEA-64303050101 50
WEDGY - D01 18' CEA-64301060101 50 CEA-64302060101 50 CEA-64303060101 25
3' CEA-64302010102 25
173
CEA-64303010102 25
173
6' CEA-64302020102 25 CEA-64303020102 25
9' CEA-64302030102 25 CEA-64303030102 25
12' CEA-64302040102 25 CEA-64303040102 25
15' CEA-64302050102 25 CEA-64303050102 25
DSCL2 or 3 - D02 18' CEA-64302060102 25 CEA-64303060102 25
3' CEA-64302010103 25
104
CEA-64303010103 25
104
6' CEA-64302020103 25 CEA-64303020103 25
9' CEA-64302030103 25 CEA-64303030103 25
12' CEA-64302040103 25 CEA-64303040103 25
15' CEA-64302050103 25 CEA-64303050103 25
DSCU2 or 3 - D03 18' CEA-64302060103 25 CEA-64303060103 25
3' CEA-64301010104 25
77
CEA-64302010104 25 Upper Attach CEA-64303010104 25 Upper Attach
6' CEA-64301020104 25 CEA-64302020104 25104
CEA-64303020104 25104
9' CEA-64301030104 25 CEA-64302030104 25 CEA-64303030104 25
12' CEA-64301040104 25 CEA-64302040104 25 Lower Attach CEA-64303040104 25 Lower Attach
15' CEA-64301050104 25 CEA-64302050104 25173
CEA-64303050104 25173
WEDGY & DSC - D04 18' CEA-64301060104 25 CEA-64302060104 25 CEA-64303060104 25
3' CEA-64302010105 100
163
CEA-64303010105 100
216
6' CEA-64302020105 100 CEA-64303020105 50
9' CEA-64302030105 50 CEA-64303030105 50
12' CEA-64302040105 50 CEA-64303040105 50
15' CEA-64302050105 50 CEA-64303050105 50
SWP2 or 3 - D05 18' CEA-64302060105 50 CEA-64303060105 25
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
Wedgy with AB 90° Clip Hex Lag
Fig 643
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 13.• Capacities Shown in the table below account for the connection to structure with a 1/4” x 2-1/2” Hex Lag.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
FIG
64
3
Illustrations are not to scale
Example:CEA-64302030101
A02 = No. 2 CableB03 = 9’ CableC01 = 643 - 90 Degree Bracket with 1/4” x 2-1/2” Hex Lag. (See Page 13)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
35
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-64401010101 100
77
CEA-64402010101 100
130
CEA-64403010101 100
130
6' CEA-64401020101 100 CEA-64402020101 100 CEA-64403020101 50
9' CEA-64401030101 50 CEA-64402030101 50 CEA-64403030101 50
12' CEA-64401040101 50 CEA-64402040101 50 CEA-64403040101 50
15' CEA-64401050101 50 CEA-64402050101 50 CEA-64403050101 50
WEDGY - D01 18' CEA-64401060101 50 CEA-64402060101 50 CEA-64403060101 25
3' CEA-64402010102 25
130
CEA-64403010102 25
130
6' CEA-64402020102 25 CEA-64403020102 25
9' CEA-64402030102 25 CEA-64403030102 25
12' CEA-64402040102 25 CEA-64403040102 25
15' CEA-64402050102 25 CEA-64403050102 25
DSCL2 or 3 - D02 18' CEA-64402060102 25 CEA-64403060102 25
3' CEA-64402010103 25
104
CEA-64403010103 25
104
6' CEA-64402020103 25 CEA-64403020103 25
9' CEA-64402030103 25 CEA-64403030103 25
12' CEA-64402040103 25 CEA-64403040103 25
15' CEA-64402050103 25 CEA-64403050103 25
DSCU2 or 3 - D03 18' CEA-64402060103 25 CEA-64403060103 25
3' CEA-64401010104 25
77
CEA-64402010104 25 Upper Attach CEA-64403010104 25 Upper Attach
6' CEA-64401020104 25 CEA-64402020104 25104
CEA-64403020104 25104
9' CEA-64401030104 25 CEA-64402030104 25 CEA-64403030104 25
12' CEA-64401040104 25 CEA-64402040104 25 Lower Attach CEA-64403040104 25 Lower Attach
15' CEA-64401050104 25 CEA-64402050104 25130
CEA-64403050104 25130
WEDGY & DSC - D04 18' CEA-64401060104 25 CEA-64402060104 25 CEA-64403060104 25
3' CEA-64402010105 100
130
CEA-64403010105 100
130
6' CEA-64402020105 100 CEA-64403020105 50
9' CEA-64402030105 50 CEA-64403030105 50
12' CEA-64402040105 50 CEA-64403040105 50
15' CEA-64402050105 50 CEA-64403050105 50
SWP2 or 3 - D05 18' CEA-64402060105 50 CEA-64403060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
Wedgy with AB 45° Clip Hex Lag
Fig 644
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Assembly maximum capacities vary by substrate and embedment. For additional fastener options or attachments with higher values refer to Page 13.• Capacities Shown in the table below account for the connection to structure with a 1/4” x 2-1/2” Hex Lag.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
FIG
64
4
Illustrations are not to scale
Example:CEA-64402030101
A02 = No. 2 CableB03 = 9’ CableC01 = 644 - 45 Degree Bracket with 1/4” x 2-1/2” Hex Lag. (See Page 13)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
36
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-66001010101 50
77
CEA-66002010101 50
158
CEA-66003010101 50
300
6' CEA-66001020101 50 CEA-66002020101 25 CEA-66003020101 25
9' CEA-66001030101 25 CEA-66002030101 25 CEA-66003030101 25
12' CEA-66001040101 25 CEA-66002040101 25 CEA-66003040101 25
15' CEA-66001050101 25 CEA-66002050101 25 CEA-66003050101 25
WEDGY - D01 18' CEA-66001060101 25 CEA-66002060101 25 CEA-66003060101 25
3' CEA-66002010102 20
173
CEA-66003010102 20
173
6' CEA-66002020102 20 CEA-66003020102 20
9' CEA-66002030102 20 CEA-66003030102 20
12' CEA-66002040102 20 CEA-66003040102 20
15' CEA-66002050102 20 CEA-66003050102 20
DSCL2 or 3 - D02 18' CEA-66002060102 20 CEA-66003060102 20
3' CEA-66002010103 20
104
CEA-66003010103 20
104
6' CEA-66002020103 20 CEA-66003020103 20
9' CEA-66002030103 20 CEA-66003030103 20
12' CEA-66002040103 20 CEA-66003040103 20
15' CEA-66002050103 20 CEA-66003050103 20
DSCU2 or 3 - D03 18' CEA-66002060103 20 CEA-66003060103 20
3' CEA-66001010104 25
77
CEA-66002010104 20 Upper Attach CEA-66003010104 20 Upper Attach
6' CEA-66001020104 25 CEA-66002020104 20104
CEA-66003020104 20104
9' CEA-66001030104 25 CEA-66002030104 20 CEA-66003030104 20
12' CEA-66001040104 25 CEA-66002040104 20 Lower Attach CEA-66003040104 20 Lower Attach
15' CEA-66001050104 25 CEA-66002050104 20173
CEA-66003050104 20173
WEDGY & DSC - D04 18' CEA-66001060104 25 CEA-66002060104 20 CEA-66003060104 20
3' CEA-66002010105 50
163
CEA-66003010105 50
223
6' CEA-66002020105 25 CEA-66003020105 25
9' CEA-66002030105 25 CEA-66003030105 25
12' CEA-66002040105 25 CEA-66003040105 25
15' CEA-66002050105 25 CEA-66003050105 25
SWP2 or 3 - D05 18' CEA-66002060105 25 CEA-66003060105 25
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
Cast-in-Place Wedgy
Fig 660
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to structure with the Cast-in-Place Wedgy installed into metal deck with concrete. (133# Max Capacity with No Concrete)• For additional fastener options or attachments with higher values refer to Page 14.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
FIG
66
0
Illustrations are not to scale
Used with or withoutConcrete
Example:CEA-66002030101
A02 = No. 2 CableB03 = 9’ CableC01 = 660 - Cast-in-Place Pigtail. (See Page 14)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
37
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-66101010101 50
77
CEA-66102010101 50
158
CEA-66103010101 50
314
6' CEA-66101020101 50 CEA-66102020101 25 CEA-66103020101 25
9' CEA-66101030101 25 CEA-66102030101 25 CEA-66103030101 25
12' CEA-66101040101 25 CEA-66102040101 25 CEA-66103040101 25
15' CEA-66101050101 25 CEA-66102050101 25 CEA-66103050101 25
WEDGY - D01 18' CEA-66101060101 25 CEA-66102060101 25 CEA-66103060101 25
3' CEA-66102010102 20
173
CEA-66103010102 20
173
6' CEA-66102020102 20 CEA-66103020102 20
9' CEA-66102030102 20 CEA-66103030102 20
12' CEA-66102040102 20 CEA-66103040102 20
15' CEA-66102050102 20 CEA-66103050102 20
DSCL2 or 3 - D02 18' CEA-66102060102 20 CEA-66103060102 20
3' CEA-66102010103 20
104
CEA-66103010103 20
104
6' CEA-66102020103 20 CEA-66103020103 20
9' CEA-66102030103 20 CEA-66103030103 20
12' CEA-66102040103 20 CEA-66103040103 20
15' CEA-66102050103 20 CEA-66103050103 20
DSCU2 or 3 - D03 18' CEA-66102060103 20 CEA-66103060103 20
3' CEA-66101010104 25
77
CEA-66102010104 20 Upper Attach CEA-66103010104 20 Upper Attach
6' CEA-66101020104 25 CEA-66102020104 20104
CEA-66103020104 20104
9' CEA-66101030104 25 CEA-66102030104 20 CEA-66103030104 20
12' CEA-66101040104 25 CEA-66102040104 20 Lower Attach CEA-66103040104 20 Lower Attach
15' CEA-66101050104 25 CEA-66102050104 20173
CEA-66103050104 20173
WEDGY & DSC - D04 18' CEA-66101060104 25 CEA-66102060104 20 CEA-66103060104 20
3' CEA-66102010105 50
163
CEA-66103010105 50
223
6' CEA-66102020105 25 CEA-66103020105 25
9' CEA-66102030105 25 CEA-66103030105 25
12' CEA-66102040105 25 CEA-66103040105 25
15' CEA-66102050105 25 CEA-66103050105 25
SWP2 or 3 - D05 18' CEA-66102060105 25 CEA-66103060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
Cast-in-Place Rebar Wedgy
Fig 661
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to structure with the Cast-in-Place Rebar Wedgy installed into metal deck with concrete. (200# Max Capacity with No Concrete)• For additional fastener options or attachments with higher values refer to Page 14.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
FIG
66
1
Illustrations are not to scale
Used with or withoutConcrete
Example:CEA-66102030101
A02 = No. 2 CableB03 = 9’ CableC01 = 661 - Cast-in-Place Rebar. (See Page 14)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
38
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-66201010101 100
77
CEA-66202010101 100
158
CEA-66203010101 100
314
6' CEA-66201020101 100 CEA-66202020101 100 CEA-66203020101 50
9' CEA-66201030101 50 CEA-66202030101 50 CEA-66203030101 50
12' CEA-66201040101 50 CEA-66202040101 50 CEA-66203040101 50
15' CEA-66201050101 50 CEA-66202050101 50 CEA-66203050101 50
WEDGY - D01 18' CEA-66201060101 50 CEA-66202060101 50 CEA-66203060101 25
3' CEA-66202010102 25
173
CEA-66203010102 25
173
6' CEA-66202020102 25 CEA-66203020102 25
9' CEA-66202030102 25 CEA-66203030102 25
12' CEA-66202040102 25 CEA-66203040102 25
15' CEA-66202050102 25 CEA-66203050102 25
DSCL2 or 3 - D02 18' CEA-66202060102 25 CEA-66203060102 25
3' CEA-66202010103 25
104
CEA-66203010103 25
104
6' CEA-66202020103 25 CEA-66203020103 25
9' CEA-66202030103 25 CEA-66203030103 25
12' CEA-66202040103 25 CEA-66203040103 25
15' CEA-66202050103 25 CEA-66203050103 25
DSCU2 or 3 - D03 18' CEA-66202060103 25 CEA-66203060103 25
3' CEA-66201010104 25
77
CEA-66202010104 25 Upper Attach CEA-66203010104 25 Upper Attach
6' CEA-66201020104 25 CEA-66202020104 25104
CEA-66203020104 25104
9' CEA-66201030104 25 CEA-66202030104 25 CEA-66203030104 25
12' CEA-66201040104 25 CEA-66202040104 25 Lower Attach CEA-66203040104 25 Lower Attach
15' CEA-66201050104 25 CEA-66202050104 25173
CEA-66203050104 25173
WEDGY & DSC - D04 18' CEA-66201060104 25 CEA-66202060104 25 CEA-66203060104 25
3' CEA-66202010105 100
163
CEA-66203010105 100
223
6' CEA-66202020105 100 CEA-66203020105 50
9' CEA-66202030105 50 CEA-66203030105 50
12' CEA-66202040105 50 CEA-66203040105 50
15' CEA-66202050105 50 CEA-66203050105 50
SWP2 or 3 - D05 18' CEA-66202060105 50 CEA-66203060105 25
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
1/4” x 5” Eyebolt - SDI Blue Banger Hanger
Fig 662
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to a SDI143812 Blue Banger Hanger with a 1/4” Wedgy Eyebolt installed.• For additional fastener options or attachments with higher values refer to Page 14.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
FIG
66
2
Illustrations are not to scale
Metal DeckConcrete Pour
CEAS Eyewire
Pole Tool
Example:CEA-66202030101
A02 = No. 2 CableB03 = 9’ CableC01 = 662 - 1/4” x 5” Eyebolt. (See Page 14)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
39
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-66301010101 100
77
CEA-66302010101 100
158
CEA-66303010101 100
314
6' CEA-66301020101 100 CEA-66302020101 100 CEA-66303020101 50
9' CEA-66301030101 50 CEA-66302030101 50 CEA-66303030101 50
12' CEA-66301040101 50 CEA-66302040101 50 CEA-66303040101 50
15' CEA-66301050101 50 CEA-66302050101 50 CEA-66303050101 50
WEDGY - D01 18' CEA-66301060101 50 CEA-66302060101 50 CEA-66303060101 25
3' CEA-66302010102 25
173
CEA-66303010102 25
173
6' CEA-66302020102 25 CEA-66303020102 25
9' CEA-66302030102 25 CEA-66303030102 25
12' CEA-66302040102 25 CEA-66303040102 25
15' CEA-66302050102 25 CEA-66303050102 25
DSCL2 or 3 - D02 18' CEA-66302060102 25 CEA-66303060102 25
3' CEA-66302010103 25
104
CEA-66303010103 25
104
6' CEA-66302020103 25 CEA-66303020103 25
9' CEA-66302030103 25 CEA-66303030103 25
12' CEA-66302040103 25 CEA-66303040103 25
15' CEA-66302050103 25 CEA-66303050103 25
DSCU2 or 3 - D03 18' CEA-66302060103 25 CEA-66303060103 25
3' CEA-66301010104 25
77
CEA-66302010104 25 Upper Attach CEA-66303010104 25 Upper Attach
6' CEA-66301020104 25 CEA-66302020104 25104
CEA-66303020104 25104
9' CEA-66301030104 25 CEA-66302030104 25 CEA-66303030104 25
12' CEA-66301040104 25 CEA-66302040104 25 Lower Attach CEA-66303040104 25 Lower Attach
15' CEA-66301050104 25 CEA-66302050104 25173
CEA-66303050104 25173
WEDGY & DSC - D04 18' CEA-66301060104 25 CEA-66302060104 25 CEA-66303060104 25
3' CEA-66302010105 100
163
CEA-66303010105 100
223
6' CEA-66302020105 100 CEA-66303020105 50
9' CEA-66302030105 50 CEA-66303030105 50
12' CEA-66302040105 50 CEA-66303040105 50
15' CEA-66302050105 50 CEA-66303050105 50
SWP2 or 3 - D05 18' CEA-66302060105 50 CEA-66303060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to a SDI143812 Blue Banger Hanger with a 3/8” x 1-1/2” Hex Bolt installed.• For additional fastener options or attachments with higher values refer to Page 14.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
45° Clip with Hex Bolt - SDI Blue Banger Hanger
Fig 663
FIG
66
3
Illustrations are not to scale
Metal DeckConcrete Pour
Example:CEA-66302030101
A02 = No. 2 CableB03 = 9’ CableC01 = 663-1 - AB45 - 45° Clip and 3/8” x 1-1/2” Hex Bolt. (See Page 14)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
40
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-66401010101 100
77
CEA-66402010101 100
158
CEA-66403010101 100
200
6' CEA-66401020101 100 CEA-66402020101 100 CEA-66403020101 50
9' CEA-66401030101 50 CEA-66402030101 50 CEA-66403030101 50
12' CEA-66401040101 50 CEA-66402040101 50 CEA-66403040101 50
15' CEA-66401050101 50 CEA-66402050101 50 CEA-66403050101 50
WEDGY - D01 18' CEA-66401060101 50 CEA-66402060101 50 CEA-66403060101 25
3' CEA-66402010102 25
173
CEA-66403010102 25
173
6' CEA-66402020102 25 CEA-66403020102 25
9' CEA-66402030102 25 CEA-66403030102 25
12' CEA-66402040102 25 CEA-66403040102 25
15' CEA-66402050102 25 CEA-66403050102 25
DSCL2 or 3 - D02 18' CEA-66402060102 25 CEA-66403060102 25
3' CEA-66402010103 25
104
CEA-66403010103 25
104
6' CEA-66402020103 25 CEA-66403020103 25
9' CEA-66402030103 25 CEA-66403030103 25
12' CEA-66402040103 25 CEA-66403040103 25
15' CEA-66402050103 25 CEA-66403050103 25
DSCU2 or 3 - D03 18' CEA-66402060103 25 CEA-66403060103 25
3' CEA-66401010104 25
77
CEA-66402010104 25 Upper Attach CEA-66403010104 25 Upper Attach
6' CEA-66401020104 25 CEA-66402020104 25104
CEA-66403020104 25104
9' CEA-66401030104 25 CEA-66402030104 25 CEA-66403030104 25
12' CEA-66401040104 25 CEA-66402040104 25 Lower Attach CEA-66403040104 25 Lower Attach
15' CEA-66401050104 25 CEA-66402050104 25173
CEA-66403050104 25173
WEDGY & DSC - D04 18' CEA-66401060104 25 CEA-66402060104 25 CEA-66403060104 25
3' CEA-66402010105 100
163
CEA-66403010105 100
200
6' CEA-66402020105 100 CEA-66403020105 50
9' CEA-66402030105 50 CEA-66403030105 50
12' CEA-66402040105 50 CEA-66403040105 50
15' CEA-66402050105 50 CEA-66403050105 50
SWP2 or 3 - D05 18' CEA-66402060105 50 CEA-66403060105 25
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
Wedgy with Cast-in-Place Loop
Fig 664
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to structure with the 2 Cast-in-Place Wedgy installed into a metal deck with no concrete.• For additional fastener options or attachments with higher values refer to Page 14.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
FIG
66
4
Illustrations are not to scale
Used with or withoutConcrete
Example:CEA-66402030101
A02 = No. 2 CableB03 = 9’ CableC01 = 664 - Loop with 1-1/4” Washer into Min 22g Metal Deck. (See Page 14)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
41
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-66501010101 100
77
CEA-66502010101 100
158
CEA-66503010101 100
314
6' CEA-66501020101 100 CEA-66502020101 100 CEA-66503020101 50
9' CEA-66501030101 50 CEA-66502030101 50 CEA-66503030101 50
12' CEA-66501040101 50 CEA-66502040101 50 CEA-66503040101 50
15' CEA-66501050101 50 CEA-66502050101 50 CEA-66503050101 50
WEDGY - D01 18' CEA-66501060101 50 CEA-66502060101 50 CEA-66503060101 25
3' CEA-66502010102 25
173
CEA-66503010102 25
173
6' CEA-66502020102 25 CEA-66503020102 25
9' CEA-66502030102 25 CEA-66503030102 25
12' CEA-66502040102 25 CEA-66503040102 25
15' CEA-66502050102 25 CEA-66503050102 25
DSCL2 or 3 - D02 18' CEA-66502060102 25 CEA-66503060102 25
3' CEA-66502010103 25
104
CEA-66503010103 25
104
6' CEA-66502020103 25 CEA-66503020103 25
9' CEA-66502030103 25 CEA-66503030103 25
12' CEA-66502040103 25 CEA-66503040103 25
15' CEA-66502050103 25 CEA-66503050103 25
DSCU2 or 3 - D03 18' CEA-66502060103 25 CEA-66503060103 25
3' CEA-66501010104 25
77
CEA-66502010104 25 Upper Attach CEA-66503010104 25 Upper Attach
6' CEA-66501020104 25 CEA-66502020104 25104
CEA-66503020104 25104
9' CEA-66501030104 25 CEA-66502030104 25 CEA-66503030104 25
12' CEA-66501040104 25 CEA-66502040104 25 Lower Attach CEA-66503040104 25 Lower Attach
15' CEA-66501050104 25 CEA-66502050104 25173
CEA-66503050104 25173
WEDGY & DSC - D04 18' CEA-66501060104 25 CEA-66502060104 25 CEA-66503060104 25
3' CEA-66502010105 100
163
CEA-66503010105 100
223
6' CEA-66502020105 100 CEA-66503020105 50
9' CEA-66502030105 50 CEA-66503030105 50
12' CEA-66502040105 50 CEA-66503040105 50
15' CEA-66502050105 50 CEA-66503050105 50
SWP2 or 3 - D05 18' CEA-66502060105 50 CEA-66503060105 25
WedgyStud Installation
Pole Tool
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to a PIP143812 Blue Banger Hanger with a 1/4” x 4” Hex Bolt installed.• For additional fastener options or attachments with higher values refer to Page 14.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
3/8” x 2-1/2” Threaded Stud - PIP or RDI Blue Banger Hanger
Fig 665
FIG
66
5
Illustrations are not to scale
Example:CEA-66502030101
A02 = No. 2 CableB03 = 9’ CableC01 = 665 - 3/8” x 2-1/2” Threaded Stud. (See Page 14)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
42
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-66701010101 100
77
CEA-66702010101 100
158
CEA-66703010101 100
314
6' CEA-66701020101 100 CEA-66702020101 100 CEA-66703020101 50
9' CEA-66701030101 50 CEA-66702030101 50 CEA-66703030101 50
12' CEA-66701040101 50 CEA-66702040101 50 CEA-66703040101 50
15' CEA-66701050101 50 CEA-66702050101 50 CEA-66703050101 50
WEDGY - D01 18' CEA-66701060101 50 CEA-66702060101 50 CEA-66703060101 25
3' CEA-66702010102 25
173
CEA-66703010102 25
173
6' CEA-66702020102 25 CEA-66703020102 25
9' CEA-66702030102 25 CEA-66703030102 25
12' CEA-66702040102 25 CEA-66703040102 25
15' CEA-66702050102 25 CEA-66703050102 25
DSCL2 or 3 - D02 18' CEA-66702060102 25 CEA-66703060102 25
3' CEA-66702010103 25
104
CEA-66703010103 25
104
6' CEA-66702020103 25 CEA-66703020103 25
9' CEA-66702030103 25 CEA-66703030103 25
12' CEA-66702040103 25 CEA-66703040103 25
15' CEA-66702050103 25 CEA-66703050103 25
DSCU2 or 3 - D03 18' CEA-66702060103 25 CEA-66703060103 25
3' CEA-66701010104 25
77
CEA-66702010104 25 Upper Attach CEA-66703010104 25 Upper Attach
6' CEA-66701020104 25 CEA-66702020104 25104
CEA-66703020104 25104
9' CEA-66701030104 25 CEA-66702030104 25 CEA-66703030104 25
12' CEA-66701040104 25 CEA-66702040104 25 Lower Attach CEA-66703040104 25 Lower Attach
15' CEA-66701050104 25 CEA-66702050104 25173
CEA-66703050104 25173
WEDGY & DSC - D04 18' CEA-66701060104 25 CEA-66702060104 25 CEA-66703060104 25
3' CEA-66702010105 100
163
CEA-66703010105 100
223
6' CEA-66702020105 100 CEA-66703020105 50
9' CEA-66702030105 50 CEA-66703030105 50
12' CEA-66702040105 50 CEA-66703040105 50
15' CEA-66702050105 50 CEA-66703050105 50
SWP2 or 3 - D05 18' CEA-66702060105 50 CEA-66703060105 25
A t t a c h m e n t P a r t N u m b e r s
FIG
66
7
Example:CEA-66702030101
A02 = No. 2 CableB03 = 9’ CableC01 = 667 - 3/8” x 5” Threaded Stud. (See Page 14)D01 = Wedgy Device
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to a SDI143812 or SDI381258 Blue Banger Hanger • For additional fastener options or attachments with higher values refer to Page 14.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
WedgyStud Installation
Pole Tool
Part Numbers
Wedgy - 3/8” x 5” Stud
Fig 667
Illustrations are not to scale
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
43
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-66801010101 100
77
CEA-66802010101 100
158
CEA-66803010101 100
314
6' CEA-66801020101 100 CEA-66802020101 100 CEA-66803020101 50
9' CEA-66801030101 50 CEA-66802030101 50 CEA-66803030101 50
12' CEA-66801040101 50 CEA-66802040101 50 CEA-66803040101 50
15' CEA-66801050101 50 CEA-66802050101 50 CEA-66803050101 50
WEDGY - D01 18' CEA-66801060101 50 CEA-66802060101 50 CEA-66803060101 25
3' CEA-66802010102 25
173
CEA-66803010102 25
173
6' CEA-66802020102 25 CEA-66803020102 25
9' CEA-66802030102 25 CEA-66803030102 25
12' CEA-66802040102 25 CEA-66803040102 25
15' CEA-66802050102 25 CEA-66803050102 25
DSCL2 or 3 - D02 18' CEA-66802060102 25 CEA-66803060102 25
3' CEA-66802010103 25
104
CEA-66803010103 25
104
6' CEA-66802020103 25 CEA-66803020103 25
9' CEA-66802030103 25 CEA-66803030103 25
12' CEA-66802040103 25 CEA-66803040103 25
15' CEA-66802050103 25 CEA-66803050103 25
DSCU2 or 3 - D03 18' CEA-66802060103 25 CEA-66803060103 25
3' CEA-66801010104 25
77
CEA-66802010104 25 Upper Attach CEA-66803010104 25 Upper Attach
6' CEA-66801020104 25 CEA-66802020104 25104
CEA-66803020104 25104
9' CEA-66801030104 25 CEA-66802030104 25 CEA-66803030104 25
12' CEA-66801040104 25 CEA-66802040104 25 Lower Attach CEA-66803040104 25 Lower Attach
15' CEA-66801050104 25 CEA-66802050104 25173
CEA-66803050104 25173
WEDGY & DSC - D04 18' CEA-66801060104 25 CEA-66802060104 25 CEA-66803060104 25
3' CEA-66802010105 100
163
CEA-66803010105 100
223
6' CEA-66802020105 100 CEA-66803020105 50
9' CEA-66802030105 50 CEA-66803030105 50
12' CEA-66802040105 50 CEA-66803040105 50
15' CEA-66802050105 50 CEA-66803050105 50
SWP2 or 3 - D05 18' CEA-66802060105 50 CEA-66803060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
66
8
Example:CEA-66802030101
A02 = No. 2 CableB03 = 9’ CableC01 = 668 - 3/8” x 2-1/2” with Engagement Markings for Push Rod (See Page 15)D01 = Wedgy Device
WedgyStud Installation
Pole Tool
Part Numbers
Wedgy - 3/8” Push Rod PIP StudFig 668
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to a PRPIP3812 PushRod Hanger.• For additional fastener options or attachments with higher values refer to Page 15.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
44
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-66901010101 100
77
CEA-66902010101 100
158
CEA-66703010101 100
314
6' CEA-66901020101 100 CEA-66902020101 100 CEA-66903020101 50
9' CEA-66901030101 50 CEA-66902030101 50 CEA-66903030101 50
12' CEA-66901040101 50 CEA-66902040101 50 CEA-66903040101 50
15' CEA-66901050101 50 CEA-66902050101 50 CEA-66903050101 50
WEDGY - D01 18' CEA-66901060101 50 CEA-66902060101 50 CEA-66903060101 25
3' CEA-66902010102 25
173
CEA-66903010102 25
173
6' CEA-66902020102 25 CEA-66903020102 25
9' CEA-66902030102 25 CEA-66903030102 25
12' CEA-66902040102 25 CEA-66903040102 25
15' CEA-66902050102 25 CEA-66903050102 25
DSCL2 or 3 - D02 18' CEA-66902060102 25 CEA-66903060102 25
3' CEA-66902010103 25
104
CEA-66903010103 25
104
6' CEA-66902020103 25 CEA-66903020103 25
9' CEA-66902030103 25 CEA-66903030103 25
12' CEA-66902040103 25 CEA-66903040103 25
15' CEA-66902050103 25 CEA-66903050103 25
DSCU2 or 3 - D03 18' CEA-66902060103 25 CEA-66903060103 25
3' CEA-66901010104 25
77
CEA-66902010104 25 Upper Attach CEA-66903010104 25 Upper Attach
6' CEA-66901020104 25 CEA-66902020104 25104
CEA-66903020104 25104
9' CEA-66901030104 25 CEA-66902030104 25 CEA-66903030104 25
12' CEA-66901040104 25 CEA-66902040104 25 Lower Attach CEA-66903040104 25 Lower Attach
15' CEA-66901050104 25 CEA-66902050104 25173
CEA-66903050104 25173
WEDGY & DSC - D04 18' CEA-66901060104 25 CEA-66902060104 25 CEA-66903060104 25
3' CEA-66902010105 100
163
CEA-66903010105 100
223
6' CEA-66902020105 100 CEA-66903020105 50
9' CEA-66902030105 50 CEA-66903030105 50
12' CEA-66902040105 50 CEA-66903040105 50
15' CEA-66902050105 50 CEA-66903050105 50
SWP2 or 3 - D05 18' CEA-66902060105 50 CEA-66903060105 25
A t t a c h m e n t P a r t N u m b e r s
WedgyStud Installation
Pole Tool
FIG
66
9
Part Numbers
Wedgy - 3/8” Push Rod SDI Stud
Fig 669 > AVAILABLE 2018
Illustrations are not to scale
Example:CEA-66902030101
A02 = No. 2 CableB03 = 9’ CableC01 = 669 - 3/8” Push Rod SDI Stud (See Page 15)D01 = Wedgy Device
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to a PRSDI3812 Push Rod.• For additional fastener options or attachments with higher values refer to Page 15 .• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
45
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-67001010101 100
77
CEA-67002010101 100
158
CEA-67003010101 100
314
6' CEA-67001020101 100 CEA-67002020101 100 CEA-67003020101 50
9' CEA-67001030101 50 CEA-67002030101 50 CEA-67003030101 50
12' CEA-67001040101 50 CEA-67002040101 50 CEA-67003040101 50
15' CEA-67001050101 50 CEA-67002050101 50 CEA-67003050101 50
WEDGY - D01 18' CEA-67001060101 50 CEA-67002060101 50 CEA-67003060101 25
3' CEA-67002010102 25
173
CEA-67003010102 25
173
6' CEA-67002020102 25 CEA-67003020102 25
9' CEA-67002030102 25 CEA-67003030102 25
12' CEA-67002040102 25 CEA-67003040102 25
15' CEA-67002050102 25 CEA-67003050102 25
DSCL2 or 3 - D02 18' CEA-67002060102 25 CEA-67003060102 25
3' CEA-67002010103 25
104
CEA-67003010103 25
104
6' CEA-67002020103 25 CEA-67003020103 25
9' CEA-67002030103 25 CEA-67003030103 25
12' CEA-67002040103 25 CEA-67003040103 25
15' CEA-67002050103 25 CEA-67003050103 25
DSCU2 or 3 - D03 18' CEA-67002060103 25 CEA-67003060103 25
3' CEA-67001010104 25
77
CEA-67002010104 25 Upper Attach CEA-67003010104 25 Upper Attach
6' CEA-67001020104 25 CEA-67002020104 25104
CEA-67003020104 25104
9' CEA-67001030104 25 CEA-67002030104 25 CEA-67003030104 25
12' CEA-67001040104 25 CEA-67002040104 25 Lower Attach CEA-67003040104 25 Lower Attach
15' CEA-67001050104 25 CEA-67002050104 25173
CEA-67003050104 25173
WEDGY & DSC - D04 18' CEA-67001060104 25 CEA-67002060104 25 CEA-67003060104 25
3' CEA-67002010105 100
163
CEA-67003010105 100
223
6' CEA-67002020105 100 CEA-67003020105 50
9' CEA-67002030105 50 CEA-67003030105 50
12' CEA-67002040105 50 CEA-67003040105 50
15' CEA-67002050105 50 CEA-67003050105 50
SWP2 or 3 - D05 18' CEA-67002060105 50 CEA-67003060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
67
0
Example:CEA-67002030101
A02 = No. 2 CableB03 = 9’ CableC01 = 670 - 1/4” Threaded Stud (See Page 14)D01 = Wedgy Device
WedgyStud Installation
Pole Tool
Part Numbers
Wedgy - 1/4” Threaded StudFig 670 > AVAILABLE 2018
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to a PIP143812 Blue Banger Hanger.• For additional fastener options or attachments with higher values refer to Page 14.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
46
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-67101010101 100
77
CEA-67102010101 100
158
CEA-67103010101 100
314
6' CEA-67101020101 100 CEA-67102020101 100 CEA-67103020101 50
9' CEA-67101030101 50 CEA-67102030101 50 CEA-67103030101 50
12' CEA-67101040101 50 CEA-67102040101 50 CEA-67103040101 50
15' CEA-67101050101 50 CEA-67102050101 50 CEA-67103050101 50
WEDGY - D01 18' CEA-67101060101 50 CEA-67102060101 50 CEA-67103060101 25
3' CEA-67102010102 25
173
CEA-67103010102 25
173
6' CEA-67102020102 25 CEA-67103020102 25
9' CEA-67102030102 25 CEA-67103030102 25
12' CEA-67102040102 25 CEA-67103040102 25
15' CEA-67102050102 25 CEA-67103050102 25
DSCL2 or 3 - D02 18' CEA-67102060102 25 CEA-67103060102 25
3' CEA-67102010103 25
104
CEA-67103010103 25
104
6' CEA-67102020103 25 CEA-67103020103 25
9' CEA-67102030103 25 CEA-67103030103 25
12' CEA-67102040103 25 CEA-67103040103 25
15' CEA-67102050103 25 CEA-67103050103 25
DSCU2 or 3 - D03 18' CEA-67102060103 25 CEA-67103060103 25
3' CEA-67101010104 25
77
CEA-67102010104 25 Upper Attach CEA-67103010104 25 Upper Attach
6' CEA-67101020104 25 CEA-67102020104 25104
CEA-67103020104 25104
9' CEA-67101030104 25 CEA-67102030104 25 CEA-67103030104 25
12' CEA-67101040104 25 CEA-67102040104 25 Lower Attach CEA-67103040104 25 Lower Attach
15' CEA-67101050104 25 CEA-67102050104 25173
CEA-67103050104 25173
WEDGY & DSC - D04 18' CEA-67101060104 25 CEA-67102060104 25 CEA-67103060104 25
3' CEA-67102010105 100
163
CEA-67103010105 100
223
6' CEA-67102020105 100 CEA-67103020105 50
9' CEA-67102030105 50 CEA-67103030105 50
12' CEA-67102040105 50 CEA-67103040105 50
15' CEA-67102050105 50 CEA-67103050105 50
SWP2 or 3 - D05 18' CEA-67102060105 50 CEA-67103060105 25
A t t a c h m e n t P a r t N u m b e r s
FIG
67
1
Part Numbers
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to a PIP143812 Blue Banger Hanger with a 1/4” x 4” Hex Bolt installed.• For additional fastener options or attachments with higher values refer to Page 14.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
1/4” x 4” Eyebolt - PIP and RDI Blue Banger Hanger
Fig 671
Illustrations are not to scale
CEAS Eyewire
Pole Tool
Example:CEA-67102030101
A02 = No. 2 CableB03 = 9’ CableC01 = 671 - 1/4” x 4” Eyebolt. (See Page 14)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
47
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-67201010101 100
77
CEA-67202010101 100
158
CEA-67203010101 100
314
6' CEA-67201020101 100 CEA-67202020101 100 CEA-67203020101 50
9' CEA-67201030101 50 CEA-67202030101 50 CEA-67203030101 50
12' CEA-67201040101 50 CEA-67202040101 50 CEA-67203040101 50
15' CEA-67201050101 50 CEA-67202050101 50 CEA-67203050101 50
WEDGY - D01 18' CEA-67201060101 50 CEA-67202060101 50 CEA-67203060101 25
3' CEA-67202010102 25
173
CEA-67203010102 25
173
6' CEA-67202020102 25 CEA-67203020102 25
9' CEA-67202030102 25 CEA-67203030102 25
12' CEA-67202040102 25 CEA-67203040102 25
15' CEA-67202050102 25 CEA-67203050102 25
DSCL2 or 3 - D02 18' CEA-67202060102 25 CEA-67203060102 25
3' CEA-67202010103 25
104
CEA-67203010103 25
104
6' CEA-67202020103 25 CEA-67203020103 25
9' CEA-67202030103 25 CEA-67203030103 25
12' CEA-67202040103 25 CEA-67203040103 25
15' CEA-67202050103 25 CEA-67203050103 25
DSCU2 or 3 - D03 18' CEA-67202060103 25 CEA-67203060103 25
3' CEA-67201010104 25
77
CEA-67202010104 25 Upper Attach CEA-67203010104 25 Upper Attach
6' CEA-67201020104 25 CEA-67202020104 25104
CEA-67203020104 25104
9' CEA-67201030104 25 CEA-67202030104 25 CEA-67203030104 25
12' CEA-67201040104 25 CEA-67202040104 25 Lower Attach CEA-67203040104 25 Lower Attach
15' CEA-67201050104 25 CEA-67202050104 25173
CEA-67203050104 25173
WEDGY & DSC - D04 18' CEA-67201060104 25 CEA-67202060104 25 CEA-67203060104 25
3' CEA-67202010105 100
163
CEA-67203010105 100
223
6' CEA-67202020105 100 CEA-67203020105 50
9' CEA-67202030105 50 CEA-67203030105 50
12' CEA-67202040105 50 CEA-67203040105 50
15' CEA-67202050105 50 CEA-67203050105 50
SWP2 or 3 - D05 18' CEA-67202060105 50 CEA-67203060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
67
2
Part Numbers
45° Clip with Hex Bolt - PIP Blue Banger Hanger
Fig 672
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below account for the connection to a PIP143812 Blue Banger Hanger with a 3/8” Hex Bolt installed• For additional fastener options or attachments with higher values refer to Page 14.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Illustrations are not to scale
Example:CEA-67202030101
A02 = No. 2 CableB03 = 9’ CableC01 = 672-1 - 90° Clip and 3/8” x 1-1/4” Hex Bolt. (See Page 14)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
48
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-68001010101 100
77
CEA-68002010101 100
158
CEA-68003010101 100
314
6' CEA-68001020101 100 CEA-68002020101 100 CEA-68003020101 50
9' CEA-68001030101 50 CEA-68002030101 50 CEA-68003030101 50
12' CEA-68001040101 50 CEA-68002040101 50 CEA-68003040101 50
15' CEA-68001050101 50 CEA-68002050101 50 CEA-68003050101 50
WEDGY - D01 18' CEA-68001060101 50 CEA-68002060101 50 CEA-68003060101 25
3' CEA-68002010102 25
173
CEA-68003010102 25
173
6' CEA-68002020102 25 CEA-68003020102 25
9' CEA-68002030102 25 CEA-68003030102 25
12' CEA-68002040102 25 CEA-68003040102 25
15' CEA-68002050102 25 CEA-68003050102 25
DSCL2 or 3 - D02 18' CEA-68002060102 25 CEA-68003060102 25
3' CEA-68002010103 25
104
CEA-68003010103 25
104
6' CEA-68002020103 25 CEA-68003020103 25
9' CEA-68002030103 25 CEA-68003030103 25
12' CEA-68002040103 25 CEA-68003040103 25
15' CEA-68002050103 25 CEA-68003050103 25
DSCU2 or 3 - D03 18' CEA-68002060103 25 CEA-68003060103 25
3' CEA-68001010104 25
77
CEA-68002010104 25 Upper Attach CEA-68003010104 25 Upper Attach
6' CEA-68001020104 25 CEA-68002020104 25104
CEA-68003020104 25104
9' CEA-68001030104 25 CEA-68002030104 25 CEA-68003030104 25
12' CEA-68001040104 25 CEA-68002040104 25 Lower Attach CEA-68003040104 25 Lower Attach
15' CEA-68001050104 25 CEA-68002050104 25173
CEA-68003050104 25173
WEDGY & DSC - D04 18' CEA-68001060104 25 CEA-68002060104 25 CEA-68003060104 25
3' CEA-68002010105 100
163
CEA-68003010105 100
223
6' CEA-68002020105 100 CEA-68003020105 50
9' CEA-68002030105 50 CEA-68003030105 50
12' CEA-68002040105 50 CEA-68003040105 50
15' CEA-68002050105 50 CEA-68003050105 50
SWP2 or 3 - D05 18' CEA-68002060105 50 CEA-68003060105 25
A t t a c h m e n t P a r t N u m b e r s
FIG
68
0
Part Numbers
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below are for the AB90 clip and cable only. Attachments to structure are not considered.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
C01 = 3/16” Anchor Hole
C02 = 3/8” Anchor Hole
Part Number OptionsWedgy with AB90 90° Blank Clip Only
Fig 680
Example:CEA-68002030101
A02 = No. 2 CableB03 = 9’ CableC01 = 680-1 - 90° Clip Only - Cable Tied Through the (3/8”) Large Hole. (See Page 14)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
49
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-68101010101 100
77
CEA-68102010101 100
158
CEA-68103010101 100
314
6' CEA-68101020101 100 CEA-68102020101 100 CEA-68103020101 50
9' CEA-68101030101 50 CEA-68102030101 50 CEA-68103030101 50
12' CEA-68101040101 50 CEA-68102040101 50 CEA-68103040101 50
15' CEA-68101050101 50 CEA-68102050101 50 CEA-68103050101 50
WEDGY - D01 18' CEA-68101060101 50 CEA-68102060101 50 CEA-68103060101 25
3' CEA-68102010102 25
173
CEA-68103010102 25
173
6' CEA-68102020102 25 CEA-68103020102 25
9' CEA-68102030102 25 CEA-68103030102 25
12' CEA-68102040102 25 CEA-68103040102 25
15' CEA-68102050102 25 CEA-68103050102 25
DSCL2 or 3 - D02 18' CEA-68102060102 25 CEA-68103060102 25
3' CEA-68102010103 25
104
CEA-68103010103 25
104
6' CEA-68102020103 25 CEA-68103020103 25
9' CEA-68102030103 25 CEA-68103030103 25
12' CEA-68102040103 25 CEA-68103040103 25
15' CEA-68102050103 25 CEA-68103050103 25
DSCU2 or 3 - D03 18' CEA-68102060103 25 CEA-68103060103 25
3' CEA-68101010104 25
77
CEA-68102010104 25 Upper Attach CEA-68103010104 25 Upper Attach
6' CEA-68101020104 25 CEA-68102020104 25104
CEA-68103020104 25104
9' CEA-68101030104 25 CEA-68102030104 25 CEA-68103030104 25
12' CEA-68101040104 25 CEA-68102040104 25 Lower Attach CEA-68103040104 25 Lower Attach
15' CEA-68101050104 25 CEA-68102050104 25173
CEA-68103050104 25173
WEDGY & DSC - D04 18' CEA-68101060104 25 CEA-68102060104 25 CEA-68103060104 25
3' CEA-68102010105 100
163
CEA-68103010105 100
223
6' CEA-68102020105 100 CEA-68103020105 50
9' CEA-68102030105 50 CEA-68103030105 50
12' CEA-68102040105 50 CEA-68103040105 50
15' CEA-68102050105 50 CEA-68103050105 50
SWP2 or 3 - D05 18' CEA-68102060105 50 CEA-68103060105 25
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
68
1
Part Numbers
Wedgy with AB45 45° Blank Clip Only
Fig 681
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below are for the AB45 clip and cable only. Attachments to structure are not considered.• Assemblies can be manufactured with 2, 3, or 4 cables. Please contact CEAS for part numbers.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
C01 = 3/16” Anchor Hole
Part Number Options
C02 = 3/8” Anchor Hole
Example:CEA-68102030101
A02 = No. 2 CableB03 = 9’ CableC01 = 681-1 - 45° Clip Only - Cable Tied Through the (3/8”) Large Hole. (See Page 14)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
50
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-68201010101 100
77
CEA-68202010101 100
158
CEA-68203010101 100
314
6' CEA-68201020101 100 CEA-68202020101 100 CEA-68203020101 50
9' CEA-68201030101 50 CEA-68202030101 50 CEA-68203030101 50
12' CEA-68201040101 50 CEA-68202040101 50 CEA-68203040101 50
15' CEA-68201050101 50 CEA-68202050101 50 CEA-68203050101 50
WEDGY - D01 18' CEA-68201060101 50 CEA-68202060101 50 CEA-68203060101 25
3' CEA-68202010102 25
173
CEA-68203010102 25
173
6' CEA-68202020102 25 CEA-68203020102 25
9' CEA-68202030102 25 CEA-68203030102 25
12' CEA-68202040102 25 CEA-68203040102 25
15' CEA-68202050102 25 CEA-68203050102 25
DSCL2 or 3 - D02 18' CEA-68202060102 25 CEA-68203060102 25
3' CEA-68202010103 25
104
CEA-68203010103 25
104
6' CEA-68202020103 25 CEA-68203020103 25
9' CEA-68202030103 25 CEA-68203030103 25
12' CEA-68202040103 25 CEA-68203040103 25
15' CEA-68202050103 25 CEA-68203050103 25
DSCU2 or 3 - D03 18' CEA-68202060103 25 CEA-68203060103 25
3' CEA-68201010104 25
77
CEA-68202010104 25 Upper Attach CEA-68203010104 25 Upper Attach
6' CEA-68201020104 25 CEA-68202020104 25104
CEA-68203020104 25104
9' CEA-68201030104 25 CEA-68202030104 25 CEA-68203030104 25
12' CEA-68201040104 25 CEA-68202040104 25 Lower Attach CEA-68203040104 25 Lower Attach
15' CEA-68201050104 25 CEA-68202050104 25173
CEA-68203050104 25173
WEDGY & DSC - D04 18' CEA-68201060104 25 CEA-68202060104 25 CEA-68203060104 25
3' CEA-68202010105 100
163
CEA-68203010105 100
223
6' CEA-68202020105 100 CEA-68203020105 50
9' CEA-68202030105 50 CEA-68203030105 50
12' CEA-68202040105 50 CEA-68203040105 50
15' CEA-68202050105 50 CEA-68203050105 50
SWP2 or 3 - D05 18' CEA-68202060105 50 CEA-68203060105 25
A t t a c h m e n t P a r t N u m b e r s
FIG
68
2
Part Numbers
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below are for the clip and cable only. Attachments to structure are not considered.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Wedgy - 90° Bracket with 1/4” Anchor Hole
Fig 682
Example:CEA-68202030101
A02 = No. 2 CableB03 = 9’ CableC01 = 682 - 90° Bracket with 1/4” Anchor Hole. (See Page 14)D01 = Wedgy Device
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
51
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
A t t a c h m e n t P a r t N u m b e r s
FIG
68
3
Part Numbers
Wedgy - 90° Bracket with 3/8” Anchor Hole
Fig 683
• Provides support for Trapezes, HVAC Duct, Cable Tray, Piping and Conduit.• Quick installation and adjustment.• Engineered as a COMPLETE ASSEMBLY.• Capacities Shown in the table below are for the clip and cable only. Attachments to structure are not considered.• Cables can be ordered to any length. Please contact CEAS for part numbers.• U.S. Patent D737,134.
Example:CEA-68302030101
A02 = No. 2 CableB03 = 9’ CableC01 = 683 - 90° Bracket with 3/8” Anchor Hole. (See Page 14)D01 = Wedgy Device
Cable Length No. 1 Cable Bucket Qty Capacity No. 2 Cable Bucket Qty Capacity No. 3 Cable Bucket Qty Capacity
3' CEA-68301010101 100
77
CEA-68302010101 100
158
CEA-68303010101 100
314
6' CEA-68301020101 100 CEA-68302020101 100 CEA-68303020101 50
9' CEA-68301030101 50 CEA-68302030101 50 CEA-68303030101 50
12' CEA-68301040101 50 CEA-68302040101 50 CEA-68303040101 50
15' CEA-68301050101 50 CEA-68302050101 50 CEA-68303050101 50
WEDGY - D01 18' CEA-68301060101 50 CEA-68302060101 50 CEA-68303060101 25
3' CEA-68302010102 25
173
CEA-68303010102 25
173
6' CEA-68302020102 25 CEA-68303020102 25
9' CEA-68302030102 25 CEA-68303030102 25
12' CEA-68302040102 25 CEA-68303040102 25
15' CEA-68302050102 25 CEA-68303050102 25
DSCL2 or 3 - D02 18' CEA-68302060102 25 CEA-68303060102 25
3' CEA-68302010103 25
104
CEA-68303010103 25
104
6' CEA-68302020103 25 CEA-68303020103 25
9' CEA-68302030103 25 CEA-68303030103 25
12' CEA-68302040103 25 CEA-68303040103 25
15' CEA-68302050103 25 CEA-68303050103 25
DSCU2 or 3 - D03 18' CEA-68302060103 25 CEA-68303060103 25
3' CEA-68301010104 25
77
CEA-68302010104 25 Upper Attach CEA-68303010104 25 Upper Attach
6' CEA-68301020104 25 CEA-68302020104 25104
CEA-68303020104 25104
9' CEA-68301030104 25 CEA-68302030104 25 CEA-68303030104 25
12' CEA-68301040104 25 CEA-68302040104 25 Lower Attach CEA-68303040104 25 Lower Attach
15' CEA-68301050104 25 CEA-68302050104 25173
CEA-68303050104 25173
WEDGY & DSC - D04 18' CEA-68301060104 25 CEA-68302060104 25 CEA-68303060104 25
3' CEA-68302010105 100
163
CEA-68303010105 100
223
6' CEA-68302020105 100 CEA-68303020105 50
9' CEA-68302030105 50 CEA-68303030105 50
12' CEA-68302040105 50 CEA-68303040105 50
15' CEA-68302050105 50 CEA-68303050105 50
SWP2 or 3 - D05 18' CEA-68302060105 50 CEA-68303060105 25
Additional Ordering Options
AB45 withWedgy - D06
AB90 withWedgy - D07
Fig 926Trapezes
Y-Accessories(See Pages 53-55)
Y-Cable - Fig 693(See Page 56)
Corner Cradle(See Page 176)
Flex Saddle(See Page 176)
Pipe Hangers(See Pages 152-157)
52
A t t a c h m e n t P a r t N u m b e r s
FIG
69
0
Example:CEA-69001021201
Y Length No. 1 Cable Capacity (Lbs) No. 2 Cable Capacity (Lbs) No. 3 Cable Capacity (Lbs)
6" CEA-69001010601
63
CEA-69001020601
143
CEA-69001030601
24412" CEA-69001011201 CEA-69001021201 CEA-69001031201
18" CEA-69001011801 CEA-69001021801 CEA-69001031801
Toggles - D01 24" CEA-69001012401 CEA-69001022401 CEA-69001032401
6" CEA-69001010602
63
CEA-69001020602
143
CEA-69001030602
24412" CEA-69001011202 CEA-69001021202 CEA-69001031202
18" CEA-69001011802 CEA-69001021802 CEA-69001031802
Snap Hooks - D02 24" CEA-69001012402 CEA-69001022402 CEA-69001032402
6" CEA-69001010603
63
CEA-69001020603
143
CEA-69001030603
24412" CEA-69001011203 CEA-69001021203 CEA-69001031203
18" CEA-69001011803 CEA-69001021803 CEA-69001031803
Wedgy - D03 24" CEA-69001012403 CEA-69001022403 CEA-69001032403
6" CEA-69001010604
63
CEA-69001020604
143
CEA-69001030604
24412" CEA-69001011204 CEA-69001021204 CEA-69001031204
18" CEA-69001011804 CEA-69001021804 CEA-69001031804
Carabiner - D04 24" CEA-69001012404 CEA-69001022404 CEA-69001032404
6" CEA-69001010605
63
CEA-69001020605
143
CEA-69001030605
24412" CEA-69001011205 CEA-69001021205 CEA-69001031205
18" CEA-69001011805 CEA-69001021805 CEA-69001031805
Loop - D05 24" CEA-69001012405 CEA-69001022405 CEA-69001032405
6" CEA-69001010606
63
CEA-69001020606
143
CEA-69001030606
24412" CEA-69001011206 CEA-69001021206 CEA-69001031206
18" CEA-69001011806 CEA-69001021806 CEA-69001031806
AB90 - D06 24" CEA-69001012406 CEA-69001022406 CEA-69001032406
6" CEA-69001010607
63
CEA-69001020607
143
CEA-69001030607
24412" CEA-69001011207 CEA-69001021207 CEA-69001031207
18" CEA-69001011807 CEA-69001021807 CEA-69001031807
AB45 - D07 24" CEA-69001012407 CEA-69001022407 CEA-69001032407
6" CEA-69001010608
63
CEA-69001020608
143
CEA-69001030608
24412" CEA-69001011208 CEA-69001021208 CEA-69001031208
18" CEA-69001011808 CEA-69001021808 CEA-69001031808
AB90 - D08 24" CEA-69001012408 CEA-69001022408 CEA-69001032408
6" CEA-69001010609
63
CEA-69001020609
143
CEA-69001030609
24412" CEA-69001011209 CEA-69001021209 CEA-69001031209
18" CEA-69001011809 CEA-69001021809 CEA-69001031809
AB45 - D09 24" CEA-69001012409 CEA-69001022409 CEA-69001032409
Part Numbers
• Y-Assemblies are ideal for supporting light fixtures, basket tray, and other construction applications.• Capacities shown in the table below are for the cable assembly only. Complete assembly capacities can be determined when the fasteners are selected. • Custom cable lengths and multiple other lower attachment options are available. Contact CEAS for options.• U.S. Patent D737,134.
Y - Accessories
Options
Fig 690
A01 = Top Loop ConnectionB02 = #2 CableC12 = 12” Y LengthD01 = Toggles
53
Y Length No. 1 Cable Capacity (Lbs) No. 2 Cable Capacity (Lbs) No. 3 Cable Capacity (Lbs)
6" CEA-69101010601
63
CEA-69101020601
143
CEA-69101030601
24412" CEA-69101011201 CEA-69101021201 CEA-69101031201
18" CEA-69101011801 CEA-69101021801 CEA-69101031801
Toggles - D01 24" CEA-69101012401 CEA-69101022401 CEA-69101032401
6" CEA-69101010602
63
CEA-69101020602
143
CEA-69101030602
24412" CEA-69101011202 CEA-69101021202 CEA-69101031202
18" CEA-69101011802 CEA-69101021802 CEA-69101031802
Snap Hooks - D02 24" CEA-69101012402 CEA-69101022402 CEA-69101032402
6" CEA-69101010603
63
CEA-69101020603
143
CEA-69101030603
24412" CEA-69101011203 CEA-69101021203 CEA-69101031203
18" CEA-69101011803 CEA-69101021803 CEA-69101031803
Wedgy - D03 24" CEA-69101012403 CEA-69101022403 CEA-69101032403
6" CEA-69101010604
63
CEA-69101020604
143
CEA-69101030604
24412" CEA-69101011204 CEA-69101021204 CEA-69101031204
18" CEA-69101011804 CEA-69101021804 CEA-69101031804
Carabiner - D04 24" CEA-69101012404 CEA-69101022404 CEA-69101032404
6" CEA-69101010605
63
CEA-69101020605
143
CEA-69101030605
24412" CEA-69101011205 CEA-69101021205 CEA-69101031205
18" CEA-69101011805 CEA-69101021805 CEA-69101031805
Loop - D05 24" CEA-69101012405 CEA-69101022405 CEA-69101032405
6" CEA-69101010606
63
CEA-69101020606
143
CEA-69101030606
24412" CEA-69101011206 CEA-69101021206 CEA-69101031206
18" CEA-69101011806 CEA-69101021806 CEA-69101031806
AB90 - D06 24" CEA-69101012406 CEA-69101022406 CEA-69101032406
6" CEA-69101010607
63
CEA-690101020607
143
CEA-69101030607
24412" CEA-69101011207 CEA-69101021207 CEA-69101031207
18" CEA-69101011807 CEA-69101021807 CEA-69101031807
AB45 - D07 24" CEA-69101012407 CEA-69101022407 CEA-69101032407
6" CEA-69101010608
63
CEA-69101020608
143
CEA-69101030608
24412" CEA-69101011208 CEA-69101021208 CEA-69101031208
18" CEA-69101011808 CEA-69101021808 CEA-69101031808
AB90 - D08 24" CEA-69101012408 CEA-69101022408 CEA-69101032408
6" CEA-69101010609
63
CEA-69101020609
143
CEA-69101030609
24412" CEA-69101011209 CEA-69101021209 CEA-69101031209
18" CEA-69101011809 CEA-69101021809 CEA-69101031809
AB45 - D09 24" CEA-69101012409 CEA-69101022409 CEA-69101032409
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
• Y-Assemblies are ideal for supporting light fixtures, basket tray, and other construction applications.• Capacities shown in the table below are for the cable assembly only. Complete assembly capacities can be determined when the fasteners are selected. • Custom cable lengths and multiple other lower attachment options are available. Contact CEAS for options.• U.S. Patent D737,134.
Options
Fig 691
FIG
69
1
Wedgy 3-Way Y-Accessory
A01 = Top Loop ConnectionB02 = #2 CableC12 = 12” Y LengthD01 = Toggles
Example:CEA-69101021201
54
A t t a c h m e n t P a r t N u m b e r s
FIG
69
2
Fig 692
A01 = Top Loop ConnectionB02 = #2 CableC12 = 12” Y LengthD01 = Toggles
Y Length No. 1 Cable Capacity (Lbs) No. 2 Cable Capacity (Lbs) No. 3 Cable Capacity (Lbs)
6" CEA-69201010601
63
CEA-69201020601
143
CEA-69201030601
24412" CEA-69201011201 CEA-69201021201 CEA-69201031201
18" CEA-69201011801 CEA-69201021801 CEA-69201031801
Toggles - D01 24" CEA-69201012401 CEA-69201022401 CEA-69201032401
6" CEA-69201010602
63
CEA-69201020602
143
CEA-69201030602
24412" CEA-69201011202 CEA-69201021202 CEA-69201031202
18" CEA-69201011802 CEA-69201021802 CEA-69201031802
Snap Hooks - D02 24" CEA-69201012402 CEA-69201022402 CEA-69201032402
6" CEA-69201010603
63
CEA-69201020603
143
CEA-69201030603
24412" CEA-69201011203 CEA-69201021203 CEA-69201031203
18" CEA-69201011803 CEA-69201021803 CEA-69201031803
Wedgy - D03 24" CEA-69201012403 CEA-69201022403 CEA-69201032403
6" CEA-69201010604
63
CEA-69201020604
143
CEA-69201030604
24412" CEA-69201011204 CEA-69201021204 CEA-69201031204
18" CEA-69201011804 CEA-69201021804 CEA-69201031804
Carabiner - D04 24" CEA-69201012404 CEA-69201022404 CEA-69201032404
6" CEA-69201010605
63
CEA-69201020605
143
CEA-69201030605
24412" CEA-69201011205 CEA-69201021205 CEA-69201031205
18" CEA-69201011805 CEA-69201021805 CEA-69201031805
Loop - D05 24" CEA-69201012405 CEA-69201022405 CEA-69201032405
6" CEA-69201010606
63
CEA-69201020606
143
CEA-69201030606
24412" CEA-69201011206 CEA-69201021206 CEA-69201031206
18" CEA-69201011806 CEA-69201021806 CEA-69201031806
AB90 - D06 24" CEA-69201012406 CEA-69201022406 CEA-69201032406
6" CEA-69201010607
63
CEA-692101020607
143
CEA-69201030607
24412" CEA-69201011207 CEA-69201021207 CEA-69201031207
18" CEA-69201011807 CEA-69201021807 CEA-69201031807
AB45 - D07 24" CEA-69201012407 CEA-69201022407 CEA-69201032407
6" CEA-69201010608
63
CEA-69201020608
143
CEA-69201030608
24412" CEA-69201011208 CEA-69201021208 CEA-69201031208
18" CEA-69201011808 CEA-69201021808 CEA-69201031808
AB90 - D08 24" CEA-69201012408 CEA-69201022408 CEA-69201032408
6" CEA-69201010609
63
CEA-69201020609
143
CEA-69201030609
24412" CEA-69201011209 CEA-69201021209 CEA-69201031209
18" CEA-69201011809 CEA-69201021809 CEA-69201031809
AB45 - D09 24" CEA-69201012409 CEA-69201022409 CEA-69201032409
Part Numbers
• Y-Assemblies are ideal for supporting light fixtures, basket tray, and other construction applications.• Capacities shown in the table below are for the cable assembly only. Complete assembly capacities can be determined when the fasteners are selected. • Custom cable lengths and multiple other lower attachment options are available. Contact CEAS for options.• U.S. Patent D737,134.
Wedgy 4-Way Y-Accessory
Options
Example:CEA-69201021201
55
C - Cable Length
Y - Length No. 1 Cable Capacity No. 2 Cable Capacity No. 3 Cable Capacity
3'
12"
CEA-693A6__01011201
77
CEA-693A6__02011201
158
CEA-693A6__03011201
216
6' CRA-693A6__01021201 CRA-693A6__02021201 CRA-693A6__03021201
9' CEA-693A6__01031201 CEA-693A6__02031201 CEA-693A6__03031201
12' CEA-693A6__01041201 CEA-693A6__02041201 CEA-693A6__03041201
15' CEA-693A6__01051201 CEA-693A6__02051201 CEA-693A6__03051201
3'
18"
CEA-693A6__01011801
77
CEA-693A6__02011801
158
CEA-693A6__03011801
216
6' CEA-693A6__01021801 CEA-693A6__02021801 CEA-693A6__03021801
9' CEA-693A6__01031801 CEA-693A6__02031801 CEA-693A6__03031801
12' CEA-693A6__01041801 CEA-693A6__02041801 CEA-693A6__03041801
15' CEA-693A6__01051801 CEA-693A6__02051801 CEA-693A6__03051801
3'
24"
CEA-693A6__01012401
77
CEA-693A6__02012401
158
CEA-693A6__03012401
216
6' CRA-693A6__01022401 CRA-693A6__02022401 CRA-693A6__03022401
9' CEA-693A6__01032401 CEA-693A6__02032401 CEA-693A6__03032401
12' CEA-693A6__01042401 CEA-693A6__02042401 CEA-693A6__03042401
15' CEA-693A6__01052401 CEA-693A6__02052401 CEA-693A6__03052401
3'
12"
CEA-693A6__01011202
77
CEA-693A6__02011202
158
CEA-693A6__03011202
216
6' CEA-693A6__01021202 CEA-693A6__02021202 CEA-693A6__03021202
9' CEA-693A6__01031202 CEA-693A6__02031202 CEA-693A6__03031202
12' CEA-693A6__01041202 CEA-693A6__02041202 CEA-693A6__03041202
15' CEA-693A6__01051202 CEA-693A6__02051202 CEA-693A6__03051202
3'
18"
CEA-693A6__01011802
77
CEA-693A6__02011802
158
CEA-693A6__03011802
216
6' CRA-693A6__01021802 CRA-693A6__02021802 CRA-693A6__03021802
9' CEA-693A6__01031802 CEA-693A6__02031802 CEA-693A6__03031802
12' CEA-693A6__01041802 CEA-693A6__02041802 CEA-693A6__03041802
15' CEA-693A6__01051802 CEA-693A6__02051802 CEA-693A6__03051802
3'
24"
CEA-693A6__01012402
77
CEA-693A6__02012402
158
CEA-693A6__03012402
216
6' CEA-693A6__01022402 CEA-693A6__02022402 CEA-693A6__03022402
9' CEA-693A6__01032402 CEA-693A6__02032402 CEA-693A6__03032402
12' CEA-693A6__01042402 CEA-693A6__02042402 CEA-693A6__03042402
15' CEA-693A6__01052402 CEA-693A6__02052402 CEA-693A6__03052402
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Part Numbers
A t t a c h m e n t P a r t N u m b e r s
Wedgy Y-Assembly
Fig 693• Y-Assemblies are ideal for supporting light fixtures, basket tray, and other construction applications.• Capacities shown in the table below are for the cable assembly only. Complete assembly capacities can be determined when the fasteners are selected.• Custom cable lengths and multiple other lower attachment options are available. Contact CEAS for options.• Wedgy included with every assembly.• U.S. Patent D737,134.
Options
Options
FIG
69
3
Ordering Options:To select a fastener determine the required capacity and simply refer to pages 24 through 51 and input.
Toggles - E01
Snap Hooks - E02
Example:CEA-693A600-102031201
A600-1 = Powers Pin and Clip with 1-1/8” Embedment. (See Page 18) B02 = #2 CableC03 = 9’ Cable LengthD12 = 12” Y LengthE01 = Toggles
56
C a b l e S u p p o r t A p p l i c a t i o n s
Applications
Single Hung SupportsTrapeze and Cable Tray SupportsCeiling Mounted Light Fixture SupportsPendant Hung Light Fisture Supports
700 Series - Electrical and Low Voltage Cable Supports
Round and Oval Duct SupportsRectangular Duct SupportsFixture SupportsEquipment Supports
800 Series - HVAC Cable Supports
Single Hung SupportsTrapeze and Cable Tray SupportsEquipment Supports
900 Series - Plumbing and Piping Cable Supports
CEAS Cable Supports are engineered to suspend all types of Electrical, Low Voltage, HVAC, Plumping, Piping and Mechanial equipment.
CEAS cable supports are pre-assembled and can be installed without the need of preperation or additional tools.
Innovative cable supports from CEAS save you time and money!
QUICK &
EASY
INST
ALLAT
ION
SAVES
LABO
R
SAVES
TIM
E
57
Fig 724Wedgy Trapeze with EMT
Snap‐in Clips
Fig 729Wedgy 2‐Tier CRC Cable Tray
Support
Fig 726Wedgy Strut Trapeze
Fig 730Single Wedgy Arms for
Strut Trapeze
Fig 736Wedgy Cable Tray
Direct Connect with “Y” Upper Adjust
Fig 727Wedgy 2‐Tier Strut
Trapeze
Fig 731Single Wedgy Arms for
2‐Tier Strut Trapeze
Fig 737Wedgy Cable Tray
Direct Connect with “Y” Lower Adjust
Fig 728Wedgy CRC Cable Tray
Support
Fig 735Wedgy Cable Tray – Direct Connect with 2 Supports
Fig. 724-737 Wedgy Electrical Trapeze Supports
Wedgy cable support solutions are used by electrical professionals in the construction industry around the world.
Whether your attaching to concrete, metal or wood, look no further than CEAS for suspended cable management, lighting and much more.
E l e c t r i c a l / L o w V o l t a g e S o l u t i o n s
Product Index - Wedgy 700 Series Cable Supports
70
0 S
ER
IES
58
Fig 760Wedgy Single Hung
Pendant Fixture Support
Fig 771Fastball Pendant Fixture 4
Way Sway Splay
Fig 761Fastball 3 Way Splay for
Single Hung Pendant Fixture
Fig 770Wedgy Pendant Hung Light
Fixture Support
STEELMETAL
Fig. 750-757 Wedgy Electrical Ceiling Mounted Light Fixture Supports
Fig. 760-783 Wedgy Electrical Pendant Hung Light Fixture Supports
Fig 750Ceiling Mounted Light Fixture with 2 Common
Safety Cables
Fig 752Ceiling Mounted Light Fixture with 4 Common
Safety Cables
Fig 753Drop In Ceiling Mounted Light Fixture Support
Fig 772Wedgy Pendant Fixture 4
Way Sway Splay
Fig 756Ceiling Mounted Light
Fixture with 2 Individual Safety Cables
Fig 755Ceiling Mounted Light
Fixture with 1 Individual Safety Cable
Fig 773Fastball Web Sway Bracing
System
Fig 774 Wedgy “Y” Toggle Pendant Hung Light Fixture Support
Fig 757Ceiling mounted Light
Fixture with 4 Individual Safety Cables
70
0 S
ER
IES
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m 59
FIG
72
4
Cable Assembly Capacity (Per Cable)1
3/32” Cable
1/8” Cable112#
Trapeze Capacity
24” Wide
36” Wide
100#
80#
A(6**) B C D E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 Qty
Fig 724
Fig 724
Fig 724
A B C D E
Attachment to Structure 1, 2
CableDiameter
CableLength
CRCWidth
ConduitSize4Concrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)3 73# 640-1 Wood Eyelag - 1/4” x 3” 208# *02 3/32" Cable *01 3’
*01
1/2” EMT5
600-2 Powers Pin & Clip (7/8” Embed.)3 42# 640-2 Wood Eyelag - 1/4” x 4” 208# *03 1/8" Cable *02 6’ 1-1/2” O.C.7
600-3 Ramset Pin & Clip (1-1/8” Embed.)3 72# 640-3 Wood Eyelag - 1/4” x 5” 208# *03 9’ 0.54 Lbs/LF
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 119# 641 Timberpin 77# *04 12’
*02
3/4” EMT5
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 84# Cast-in-Place Connections Load *05 15’ 1-3/4” O.C.7
601-2 90° Clip and 3/8” x 3” Tapcon 165#660
Pigtail Loop - 20g Deck (No Fill) 102# *06 18’ 0.92 Lbs/LF
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 231# *07 21’
*03
1” EMT5
602-2 90° Clip and 3/8” x 3” Wedge Anchor 200#661
Rebar Tie - 22g Deck (No Fill) 154# *08 24’ 2” O.C.7
605 Tie Wire Wedge Anchor (1/4" Dia.) 77# Rebar Tie - 22g Deck with LWC 314# *09 27’ 1.38 Lbs/LF
606 Tie Wire Spike Anchor (1/4" Dia.) 53# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
*04
1-1/4” EMT6
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom 2-1/4” O.C.7
620 Loop Connection 112# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314# 2.33 Lbs/LF
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 96# 669 3/8 x 5" Stud (SDI PushRod) 314#
*05
1-1/2” EMT6
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 96# Angle Clip Only Load 2-1/2” O.C.7
622 Bar Joist Pull-down Clamp 231# 682 90° Bracket with 1/4" Anchor Hole N/A 3.36 Lbs/LF
623 Hammer-on Beam Clamp 154# 683 90° Bracket with 3/8" Anchor Hole N/A
*25 Other624-1 90° Clip and #10 HWH Self Driller (20g) 80#
624-2 90° Clip and #10 HWH Sharp Point (22g) 35#
628 Snaphook for 1/4" Hole 77#
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:
1) Ultimate capacities have been reduced to take into consideration eccentric loads on the trapeze2) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-153) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
4) EMT weights are calculated with 40% conductor fill5) Snap in style conduit supports are used for 1/2” EMT thru 1” EMT6) Conduit Clips are used for 1‐1/4” and 1‐1/2” EMT7) The O.C. dimension refers to the clip spacing
Assembly contains:• 2ea Cable assemblies with selected anchors• 1ea CRC Trapeze with Single Wedgys pressed in and selected conduit clips installed
• Provides support for Conduit• Quick installation and adjustment• Prefabricated trapezes save time and money• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 2 4 Wedgy Trapeze with EMT Snap-in Clips
A
C
B
D
.75”
E1-E10
60
FIG
72
4
Wedgy Trapeze with EMT Snap‐in ClipsFig 724
How to determine the Wedgy Complete Assembly Capacity
Cable Assembly Capacity (Per Cable)1
3/32” Cable
1/8” Cable112#Trapeze Capacity
24” Wide
36” Wide
100#
80#
Attachment to StructureCable Assembly CapacityTrapeze Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable22” Wide Trapeze
73#112#
146#224#100#100#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
FOOTNOTES:
1) Capacities are reduced to account for the potential of eccentric loading on trapezes
Refer to page 169 for conduit weights to determine support spacing requirements
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.C) Determine the Trapeze Capacity.
Step 2:The lessor of the 3 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m 61
FIG
72
6
Cable Assembly Capacity1
3/32” Cable
1/8” Cable
125#
231#
A(6**) B C D E Qty
Fig 726
Fig 726
Fig 726
A B C D E
Attachment to Structure2
CableDiameter
CableLength
CRCWidth
ConduitSize4Concrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)3 73# 640-1 Wood Eyelag - 1/4” x 3” 208# *02 3/32" Cable *01 3’
*01
600-2 Powers Pin & Clip (7/8” Embed.)3 42# 640-2 Wood Eyelag - 1/4” x 4” 208# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)3 72# 640-3 Wood Eyelag - 1/4” x 5” 208# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 119# 641 Timberpin 77# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 84# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 165#660
Pigtail Loop - 20g Deck (No Fill) 102# *06 18’
*02
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 231# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 200#661
Rebar Tie - 22g Deck (No Fill) 154# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 77# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 53# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
*03
620 Loop Connection 112# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 96# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 96# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 231# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 154# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 80#
624-2 90° Clip and #10 HWH Sharp Point (22g) 35#
628 Snaphook for 1/4" Hole 77#
Strut Capacities
Width14g 13/16"
Strut
14g 13/16" Back to Back
Strut
12g 1-5/8" Strut
24” 185# 495# 650#
36" 120# 330# 450#
48" 65# 245# 340#
60" 40# 195# 275#
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:
1) Ultimate capacities have been reduced to take into consideration eccentric loads on the trapeze2) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-153) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#
Assembly contains:• 2ea Cable assemblies with selected anchors• 1ea Strut Trapeze with Single Wedgys pressed in
• Provides support for Conduit or Cable Tray• Quick installation and adjustment• Prefabricated trapezes save time and money• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 2 6 Wedgy Strut Trapeze
14g PHD1301
14g PHD1301A
12g PHD1001
A
C
B
D
.75”
E
62
FIG
72
6
Wedgy Strut TrapezeFig 726
How to determine the Wedgy Complete Assembly Capacity
Cable Assembly Capacity1
3/32” Cable
1/8” Cable
125#
231#Strut Capacities
Width14g 13/16"
Strut
14g 13/16" Back to Back
Strut
12g 1-5/8" Strut
24” 185# 495# 650#
36" 120# 330# 450#
48" 65# 245# 340#
60" 40# 195# 275#
Attachment to StructureCable Assembly CapacityTrapeze Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable33” Wide with 1-5/8” Strut
73#125#
146#250#450#146#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
FOOTNOTES:
1) Capacities are reduced to account for the potential of eccentric loading on trapezes
Refer to page 169 for conduit weights to determine support spacing requirements
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.C) Determine the Trapeze Capacity.
Step 2:The lessor of the 3 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m 63
FIG
72
7
A B C D E
Attachment to Structure2
CableDiameter
CableLength
CRCWidth
ConduitSize4Concrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)3 73# 640-1 Wood Eyelag - 1/4” x 3” 208# *02 3/32" Cable *01 3’
*01
600-2 Powers Pin & Clip (7/8” Embed.)3 42# 640-2 Wood Eyelag - 1/4” x 4” 208# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)3 72# 640-3 Wood Eyelag - 1/4” x 5” 208# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 119# 641 Timberpin 77# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 84# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 165#660
Pigtail Loop - 20g Deck (No Fill) 102# *06 18’
*02
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 231# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 200#661
Rebar Tie - 22g Deck (No Fill) 154# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 77# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 53# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
*03
620 Loop Connection 112# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 96# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 96# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 231# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 154# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 80#
624-2 90° Clip and #10 HWH Sharp Point (22g) 35#
628 Snaphook for 1/4" Hole 77#
Strut Capacities
Width14g 13/16"
Strut
14g 13/16" Back to Back
Strut
12g 1-5/8" Strut
24” 185# 495# 650#
36" 120# 330# 450#
48" 65# 245# 340#
60" 40# 195# 275#
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:
1) Ultimate capacities have been reduced to take into consideration eccentric loads on the trapeze2) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-153) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
14g PHD1301
14g PHD1301A
12g PHD1001
Assembly contains:• 2ea Cable assemblies with selected anchors• 2ea Strut Trapeze with Single Wedgys pressed in
• Provides support for Conduit or Cable Tray• Quick installation and adjustment• Prefabricated trapezes save time and money• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 2 7 Wedgy 2-Tier Strut Trapeze
Cable Assembly Capacity1
3/32” Cable
1/8” Cable
125#
231#
A(6**) B C D E Qty
Fig 727
Fig 727
Fig 727
A
C
B
D
.75”
E
64
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
72
7
Wedgy 2-Tier Strut TrapezeFig 727
How to determine the Wedgy Complete Assembly Capacity
Strut Capacities
Width14g 13/16"
Strut
14g 13/16" Back to Back
Strut
12g 1-5/8" Strut
24” 185# 495# 650#
36" 120# 330# 450#
48" 65# 245# 340#
60" 40# 195# 275#
Attachment to StructureCable Assembly CapacityTrapeze Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable33” Wide with 1-5/8” Strut
73#125#
146#250#450#146#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
FOOTNOTES:
1) Capacities noted are for each individual tier of the trapeze. The total Weight per Linear Foot of the utility for each tier must be calculated and can not exceed the capacity of the attachment to structure. 2) Capacities are reduced to account for the potential of eccentric loading on trapezes
Refer to page 169 for conduit weights to determine support spacing requirements
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.C) Determine the Trapeze Capacity.
Step 2:The lessor of the 3 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity 2
3/32” Cable
1/8” Cable
125#
231#
65
FIG
72
8
A B C D
Attachment to Structure1
CableDiameter
CableLength
CRCWidthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:
1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 2ea Cable assemblies with selected anchors• 1ea CRC Trapezes with Single Wedgys pressed in
• Provides support for Conduit or Cable Tray• Quick installation and adjustment• Prefabricated trapezes save time and money• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 2 8 Wedgy CRC Cable Tray Support
A(6**) B C D Qty
Fig 728
Fig 728
Fig 728
Cable Assembly Capacity
3/32” Cable
1/8” Cable146#
Trapeze Capacity
24” Wide
36” Wide
100#
80#
A
C
B
D
.75”
66
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
72
8
Wedgy CRC Cable Tray SupportFig 728
How to determine the Wedgy Complete Assembly Capacity
Attachment to StructureCable Assembly CapacityTrapeze Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable22” Wide Trapeze
95#146#
190#292#100#100#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.C) Determine the Trapeze Capacity.
Step 2:The lessor of the 3 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
3/32” Cable
1/8” Cable146#Trapeze Capacity
24” Wide
36” Wide
100#
80#
67
FIG
72
9
A B C D
Attachment to Structure1
CableDiameter
CableLength
CRCWidthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 2ea Cable assemblies with selected anchors• 2ea CRC Trapezes with Single Wedgys pressed in
• Provides support for Conduit or Cable Tray• Quick installation and adjustment• Prefabricated trapezes save time and money• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 2 9 Wedgy 2-Tier CRC Cable Tray Support
A(6**) B C D Qty
Fig 729
Fig 729
Fig 729
Cable Assembly Capacity
3/32” Cable
1/8” Cable146#
Trapeze Capacity
24” Wide
36” Wide
100#
80#
A
C
B
D
.75”
68
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
72
9
Wedgy 2-Tier CRC Cable Tray SupportFig 729
How to determine the Wedgy Complete Assembly Capacity
Attachment to StructureCable Assembly CapacityTrapeze Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable22” Wide Trapeze
95#146#
190#292#100#100#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.C) Determine the Trapeze Capacity.
Step 2:The lessor of the 3 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
3/32” Cable
1/8” Cable146#Trapeze Capacity
24” Wide
36” Wide
100#
80#
FOOTNOTES:
1) Capacities noted are for each individual tier of the trapeze. The total Weight per Linear Foot of the utility for each tier must be calculated and can not exceed the capacity of the attachment to structure.
69
FIG
73
0
A B C
Attachment to Structure2
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)3 73# 640-1 Wood Eyelag - 1/4” x 3” 208# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)3 42# 640-2 Wood Eyelag - 1/4” x 4” 208# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)3 72# 640-3 Wood Eyelag - 1/4” x 5” 208# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 119# 641 Timberpin 77# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 84# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 165#660
Pigtail Loop - 20g Deck (No Fill) 102# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 231# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 200#661
Rebar Tie - 22g Deck (No Fill) 154# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 77# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 53# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 112# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 96# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 96# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 231# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 154# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 80#
624-2 90° Clip and #10 HWH Sharp Point (22g) 35#
628 Snaphook for 1/4" Hole 77#
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Ultimate capacities have been reduced to take into consideration eccentric loads on the trapeze2) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-153) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 2ea Cable assemblies with selected anchors• 2ea Single Wedgys
Qty.2ea
• Provides support for Conduit or Cable Tray• Quick installation and adjustment• Wedgy arms are designed for punched or slotted strut• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 3 0 Single Wedgy Arms for Strut Trapeze
A(6**) B C Qty
Fig 730
Fig 730
Fig 730
Cable Assembly Capacity1
3/32” Cable
1/8” Cable
126#
223#
A
CB
70
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
73
0
Single Wedgy Arms for Strut TrapezeFig 730
How to determine the Wedgy Complete Assembly Capacity1
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
73#126#
146#252#146#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
FOOTNOTES:
1) Capacties shown are for the cable assembly and attachment to structure only. The trapeze is not taken into consideration.2) Capacties are reduced to account for the potential of eccentric loading on trapezes
Cable Assembly Capacity 2
3/32” Cable
1/8” Cable
126#
223#
71
FIG
73
1
A B C
Attachment to Structure2
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)3 73# 640-1 Wood Eyelag - 1/4” x 3” 208# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)3 42# 640-2 Wood Eyelag - 1/4” x 4” 208# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)3 72# 640-3 Wood Eyelag - 1/4” x 5” 208# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 119# 641 Timberpin 77# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 84# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 165#660
Pigtail Loop - 20g Deck (No Fill) 102# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 231# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 200#661
Rebar Tie - 22g Deck (No Fill) 154# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 77# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 53# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 112# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 96# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 96# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 231# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 154# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 80#
624-2 90° Clip and #10 HWH Sharp Point (22g) 35#
628 Snaphook for 1/4" Hole 77#
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Ultimate capacities have been reduced to take into consideration eccentric loads on the trapeze2) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-153) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 2ea Cable assemblies with selected anchors• 4ea Single Wedgys
• Provides support for Conduit or Cable Tray• Quick installation and adjustment• Wedgy arms are designed for punched or slotted strut• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 3 1 Single Wedgy Arms for 2-Tier Strut Trapeze
A(6**) B C Qty
Fig 731
Fig 731
Fig 731
Cable Assembly Capacity 1
3/32” Cable
1/8” Cable
126#
223#
Qty.2ea
Qty.4ea
A
CB
72
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
73
1
Single Wedgy Arms for 2-Tier Strut TrapezeFig 731
How to determine the Wedgy Complete Assembly Capacity 1, 2
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
73#126#
146#252#146#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
FOOTNOTES:
1) Capacities noted are for each individual tier of the trapeze. The total Weight per Linear Foot of the utility for each tier must be calculated and can not exceed the capacity of the attachment to structure. 2) Capacities shown are for the cable assembly and attachment to structure only. The trapeze is not taken into consideration. 3) Capacities are reduced to account for the potential of eccentric loading on trapezes
Cable Assembly Capacity 3
3/32” Cable
1/8” Cable
126#
223#
Refer to page 169 for conduit weights to determine support spacing requirements
73
FIG
73
5
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 2ea Cable arms with selected anchors• 2ea Wedgys
• Provides support for Conduit or Cable Tray• Quick installation and adjustment• Wedgy arms are connected directly to the tray to eliminate the need for strut and hardware• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 3 5 Wedgy Cable Tray – Direct Connect with 2 Supports
A(6**) B C Qty
Fig 735
Fig 735
Fig 735
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Qty.2ea
A
CB
74
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
73
5
Wedgy Cable Tray – Direct Connect with 2 Supports Fig 735
How to determine the Wedgy Complete Assembly Capacity
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
95#158#
190#316#190#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
75
FIG
73
6
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 1ea Cable assembly with selected anchor• 1ea Wedgy • 2ea Lower connections
• Provides support for Conduit or Cable Tray• Quick installation and adjustment• Wedgy arms are connected directly to the tray to eliminate the need for strut and hardware• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 3 6 Wedgy Cable Tray - Direct Connect with “Y” Upper Adjust
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
216#
A B C D E
Attachment to Structure1
CableDiameter
CableLength
“Y”Length
“Y”ConnectionConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’ *01 6” *01 Snap Hook
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’ *02 12” *02 Wedgy
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’ *03 18” *25 Other
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’ *04 24”
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’ *05 30”
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’ *06 36”
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’ *25 Custom
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C D E Qty
Fig 736
Fig 736
Fig 736
A
E
C
D
B
76
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
73
6
Wedgy Cable Tray – Direct Connect with “Y” ‐ Upper Adjust Fig 736
How to determine the Wedgy Complete Assembly Capacity
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
95#158#95#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
216#
77
FIG
73
7
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 1ea Cable assembly with selected anchor• 1ea Wedgy • 2ea Lower connections
• Provides support for Conduit or Cable Tray• Quick installation and adjustment• Wedgy arms are connected directly to the tray to eliminate the need for strut and hardware• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 3 7 Wedgy Cable Tray - Direct Connect with “Y” Lower Adjust
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
63#
143#
216#
A B C D E
Attachment to Structure1
CableDiameter
CableLength
“Y”Length
“Y”ConnectionConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’ *01 6” *01 Snap Hook
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’ *02 12” *02 Wedgy
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’ *03 18” *25 Other
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’ *04 24”
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’ *05 30”
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’ *06 36”
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’ *25 Custom
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C D E Qty
Fig 737
Fig 737
Fig 737
A
E
C
D
B
78
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
73
7
Wedgy Cable Tray – Direct Connect with “Y” ‐ Lower Adjust Fig 736
How to determine the Wedgy Complete Assembly Capacity
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
95#158#95#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
63#
143#
216#
79
FIG
75
0
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 1ea Assembly with 2ea Cable arms connected to 1ea selected anchors• 2ea Wedgys
• Provides safety cables for ceiling mounted light fixtures• Quick installation and adjustment• 2 cables are connected to a single anchor minimizing the number of attachments.• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 5 0 Ceiling Mounted Light Fixture with2 Common Safety Cables
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C Qty
Fig 750
Fig 750
Fig 750
A
C
B
Qty.2ea
80
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
75
0
Ceiling Mounted Light Fixture with 2 Common Safety CablesFig 750
How to determine the Wedgy Complete Assembly Capacity
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
95#158#95#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
81
FIG
75
2
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 1ea Assembly with 2ea Cable arms connected to 1ea selected anchors• 4ea Wedgys
• Designed as a support for ceiling mounted light fixtures• Quick installation and adjustment• 4 cables are connected to a single anchor minimizing the number of attachments.• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 5 2 Ceiling Mounted Light Fixture with4 Common Safety Cables
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C Qty
Fig 752
Fig 752
Fig 752
A
C
B
Qty.4ea
82
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
75
2
Ceiling Mounted Light Fixture with 4 Common Safety CablesFig 752
How to determine the Wedgy Complete Assembly Capacity
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
95#158#95#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
83
FIG
75
3
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
F i g . 7 5 3 Drop In Ceiling Mounted Light Fixture Support
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 1ea Cable assembly with selected anchor• 1ea Wedgy • 1ea Lower connections
• Provides support for Conduit or Cable Tray• Quick installation and adjustment• Wedgy arms are connected directly to the tray to eliminate the need for strut and hardware• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
63#
143#
216#
A B C D E
Attachment to Structure1
CableDiameter
CableLength
“Y”Length
“Y”ConnectionConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’ *01 6” *01 Snap Hook
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’ *02 12” *02 Wedgy
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’ *03 18” *25 Other
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’ *04 24”
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’ *05 30”
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’ *06 36”
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’ *25 Custom
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C D E Qty
Fig 753
Fig 753
Fig 753
A
E
C
D
B
84
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
75
3
Drop In Ceiling Mounted Light Fixture SupportFig 753
How to determine the Wedgy Complete Assembly Capacity
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
95#158#95#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
85
FIG
75
5
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 1ea Cable arms with selected anchor • 1ea Wedgys
• Provides a safety cable for ceiling mounted light fixtures• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 5 5 Ceiling Mounted Light Fixture with1 Individual Safety Cable
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C Qty
Fig 755
Fig 755
Fig 755
A
CB
86
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
75
5
Ceiling Mounted Light Fixture with 1 Individual Safety CableFig 755
How to determine the Wedgy Complete Assembly Capacity
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
95#158#95#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
87
FIG
75
6
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 1ea Cable arms with selected anchors• 2ea Wedgys
• Provides 2 safety cable for ceiling mounted light fixtures• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 5 6 Ceiling Mounted Light Fixture with2 Individual Safety Cable
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C Qty
Fig 756
Fig 756
Fig 756
Qty.2ea
A
CB
88
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
75
6
Ceiling Mounted Light Fixture with 2 Individual Safety CableFig 756
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
95#158#
190#316#190#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
89
FIG
75
7
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 4ea Cable arms with selected anchors• 4ea Wedgys
• Provides 4 support cables for ceiling mounted light fixtures• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 5 7 Ceiling Mounted Light Fixture with4 Individual Safety Cable
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C Qty
Fig 757
Fig 757
Fig 757
Qty.4ea
A
CB
90
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
75
7
Ceiling Mounted Light Fixture with 4 Individual Safety CableFig 757
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Attachment to StructureCable Assembly Capacity
X 4 =X 4 =
X 4 =X 4 =
600-1 Pin and Clip3/32” Cable
95#158#
380#632#380#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
91
FIG
76
0
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 1ea Cable arm with selected anchor• 1ea Wedgy
• Provides support for pendant hung light fixtures• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 6 0 Ceiling Mounted Light Fixture with4 Individual Safety Cable
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C Qty
Fig 760
Fig 760
Fig 760
A
CB
92
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
76
0
Ceiling Mounted Light Fixture with 4 Individual Safety CableFig 760
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
95#158#95#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
93
FIG
76
1
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains (Splay Arms Only):• 1ea Short cable arm with selected anchor (C Option) • 1ea Long cable arm with selected anchor (2 X C Option Length) • 1ea Loose selected anchor without cable • 1ea Wedgy • 2ea Fastballs
• Provides Sway Restraint for pendant hung light fixtures• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 6 1 Fastball 3 Way Splay for Single Hung Pendant Fixture
Maximum Fixture Weight
1/16” Cable
3/32” Cable
1/8” Cable
16#
39#
65#
Fastball Capacity
1/16” Cable
3/32” Cable
1/8” Cable
32#
78#
130#
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 145# 640-1 Wood Eyelag - 1/4” x 3” 140# *01 1/16" CableSelect the length of the short cable. The length should be atleast 1.5 times the vertical drop length. The long cable will be double the length selected.
600-2 Powers Pin & Clip (7/8” Embed.)2 120# 640-2 Wood Eyelag - 1/4” x 4” 140# *02 3/32" Cable
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 99# 640-3 Wood Eyelag - 1/4” x 5” 140# *03 1/8" Cable
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 120# 641 Timberpin 100#
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 92# Cast-in-Place Connections Load
601-2 90° Clip and 3/8” x 3” Tapcon 314#660
Pigtail Loop - 20g Deck (No Fill) 133#
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300#
602-2 90° Clip and 3/8” x 3” Wedge Anchor 168#661
Rebar Tie - 22g Deck (No Fill) 200# *01 3’
605 Tie Wire Wedge Anchor (1/4" Dia.) 90# Rebar Tie - 22g Deck with LWC 314# *02 6’
606 Tie Wire Spike Anchor (1/4" Dia.) 62# 665 45° Clip and 3/8” x 1-1/2” Hex Bolt (SDI143812 Blue Banger) 314# *03 9’
Steel Connections Load 667 45° Clip and 3/8” x 1-3/4” Hex Bolt ((SDI381258 Blue Banger) 314# *04 12’
620 Loop Connection 314# 668 45° Clip and 3/8” x 1-1/2” Hex Bolt ((PIP143812 Blue Banger) 314# *05 15’
625-1 45° Clip w/ #10 HWH Self Driller (20g) 99# 669 45° Clip and 3/8” x 1-3/4” Hex Bolt ((PIP381258 Blue Banger) 314# *06 18’
625-2 45° Clip w/ #10 HWH Sharp Point (22g) 44# Angle Clip Only Load *07 21’
627-1 45° Clip w/2ea #10 HWH Self Drillers (20g) 198# 682 90° Bracket with 1/4" Anchor Hole N/A *08 24’
627-2 45° Clip w/2ea #10 HWH Sharp Point(20g) 88# 683 90° Bracket with 3/8" Anchor Hole N/A *09 27’
*10 30’
*25 Custom
A(6**) B C Qty
Fig 761
Fig 761
Fig 761
A
CB
Qty.2ea
94
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
76
1
Fastball 3 Way Splay for Single Hung Pendant FixtureFig 761
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the Attachment to Structure. (Listed in column A or on Pages 10-15)B) Select the cable diameter of the Brace Arms.C) Determine the Demand Load at each Connection to Structure. Demand Load = Fixture Weight X 2 (Brace Reaction Load Increase)
Step 2:Confirm that the Demand Load is less than the Cable Assembly Capacity and Attachment to Structure.
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Fastball Capacity
1/16” Cable
3/32” Cable
1/8” Cable
32#
78#
130#
Attachment to StructureFastball Capacity
Fixture Wt.Fixture Wt. Fixture Wt.X 2 X 2Demand Load
600-1 Pin and Clip3/32” Cable
145#78#
30# 60#
Variable VariableCapacity Capacity
Example
Confirm that the Demand Load is less than either of these values.
Actual
95
FIG
77
0
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 2ea Cable arm with selected anchor• 2ea Wedgys
• Provides support for pendant hung light fixtures• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 7 0 Wedgy Pendant Hung Light Fixture Support
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A(6**) B C Qty
Fig 770
Fig 770
Fig 770
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Qty.2ea
A
CB
96
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
77
0
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
Cable Assembly Capacity (Per Cable)
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
95#158#
190#316#190#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Wedgy Pendant Hung Light Fixture SupportFig 770
Don’t Forget the Mounting Brackets
Custom fixture mounts can be created as well. Just let CEAS know the dimensions.
Part # Width Height Capacity (lbs)
FMS 3-1/4” 4-3/4” 30
FMF 3-1/2” 4” 30
Quickly locks into fixture mounting holes (Available for side mount or front mounted fixtures)
FMS Side Fixture Mount
FMF Front Fixture Mount
97
Assembly contains (Splay Arms Only):• 2ea Splay Arms (3 times the length of the vertical drop to accommodate the splay)• 2ea Fastballs• 2ea Selected anchors without cable• 2ea Wedgys (for the Splay Arms)
FIG
77
1
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
• The Fastball restrains 1/16”, 3/32” & 1/8” cable.• The Fastball is quickly installed by inserting the cable into the “V Groove” and tightening a thumb screw. No Tools Required!!!!• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 7 1 Fastball Pendant Fixture 4 Way Sway Splay
Maximum Fixture Weight
1/16” Cable
3/32” Cable
1/8” Cable
44#
110#
184#
A(6**) B C Qty
Fig 771
Fig 771
Fig 771
Fastball Capacity
1/16” Cable
3/32” Cable
1/8” Cable
32#
78#
130#
A
CB
Qty.2ea
Qty.2ea
Qty.2ea
Qty.2ea
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 145# 640-1 Wood Eyelag - 1/4” x 3” 140# *01 1/16" CableSelect the length of the short cable. The length should be atleast 1.5 times the vertical drop length. The long cable will be double the length selected.
600-2 Powers Pin & Clip (7/8” Embed.)2 120# 640-2 Wood Eyelag - 1/4” x 4” 140# *02 3/32" Cable
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 99# 640-3 Wood Eyelag - 1/4” x 5” 140# *03 1/8" Cable
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 120# 641 Timberpin 100#
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 92# Cast-in-Place Connections Load
601-2 90° Clip and 3/8” x 3” Tapcon 314#660
Pigtail Loop - 20g Deck (No Fill) 133#
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300#
602-2 90° Clip and 3/8” x 3” Wedge Anchor 168#661
Rebar Tie - 22g Deck (No Fill) 200# *01 3’
605 Tie Wire Wedge Anchor (1/4" Dia.) 90# Rebar Tie - 22g Deck with LWC 314# *02 6’
606 Tie Wire Spike Anchor (1/4" Dia.) 62# 665 45° Clip and 3/8” x 1-1/2” Hex Bolt (SDI143812 Blue Banger) 314# *03 9’
Steel Connections Load 667 45° Clip and 3/8” x 1-3/4” Hex Bolt ((SDI381258 Blue Banger) 314# *04 12’
620 Loop Connection 314# 668 45° Clip and 3/8” x 1-1/2” Hex Bolt ((PIP143812 Blue Banger) 314# *05 15’
625-1 45° Clip w/ #10 HWH Self Driller (20g) 99# 669 45° Clip and 3/8” x 1-3/4” Hex Bolt ((PIP381258 Blue Banger) 314# *06 18’
625-2 45° Clip w/ #10 HWH Sharp Point (22g) 44# Angle Clip Only Load *07 21’
627-1 45° Clip w/2ea #10 HWH Self Drillers (20g) 198# 682 90° Bracket with 1/4" Anchor Hole N/A *08 24’
627-2 45° Clip w/2ea #10 HWH Sharp Point(20g) 88# 683 90° Bracket with 3/8" Anchor Hole N/A *09 27’
*10 30’
*25 Custom
98
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
77
1
FASTBALL INSTALLATION INSTRUCTIONSOnce you have inserted the cable into the Fastball twist the wing bolt until it is resting against the cable then turn an additional:
• 1 turn for 1/16” cable• 1‐1/4 turns for 3/32” cable• 1‐1/2 turns for 1/8” cable
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Fastball Pendant Fixture 4 Way Sway SplayFig 771
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the Attachment to Structure. (Listed in column A or on Pages 10-15)B) Select the cable diameter of the Brace Arms.C) Determine the Demand Load at each Connection to Structure. Demand Load = Fixture Weight X 2 (Brace Reaction Load Increase)
Step 2:Confirm that the Demand Load is less than the Cable Assembly Capacity and Attachment to Structure.
Fastball Capacity
1/16” Cable
3/32” Cable
1/8” Cable
32#
78#
130#
Attachment to StructureFastball Capacity
Fixture Wt.Fixture Wt. Fixture Wt.X 1.4 ÷ 2 X 1.4 ÷ 2Demand Load
600-1 Pin and Clip3/32” Cable
145#78#
30# 21#
Variable VariableCapacity Capacity
Example
Confirm that the Demand Load is less than either of these values.
Actual
99
Assembly contains (Splay Arms Only):• 4ea Splay Arms (1.5 times the length of the vertical drop to accommodate the splay)• 4ea Selected anchors without cable• 4ea Wedgys (for the Splay Arms)
FIG
77
2
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
• Provides a pre‐engineered and code compliant sway bracing solution• The Fastball is quickly installed by inserting the cable into the “V Groove” and tightening a thumb screw. No Tools Required!!!!• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 7 2 Wedgy Pendant Fixture 4 Way Sway Splay
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A(6**) B C Qty
Fig 772
Fig 772
Fig 772
A
CB
Qty.4ea
Qty.4ea
Qty.4ea
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 145# 640-1 Wood Eyelag - 1/4” x 3” 140# *01 1/16" CableSelect the length of the short cable. The length should be atleast 1.5 times the vertical drop length. The long cable will be double the length selected.
600-2 Powers Pin & Clip (7/8” Embed.)2 120# 640-2 Wood Eyelag - 1/4” x 4” 140# *02 3/32" Cable
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 99# 640-3 Wood Eyelag - 1/4” x 5” 140# *03 1/8" Cable
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 120# 641 Timberpin 100#
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 92# Cast-in-Place Connections Load
601-2 90° Clip and 3/8” x 3” Tapcon 314#660
Pigtail Loop - 20g Deck (No Fill) 133#
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300#
602-2 90° Clip and 3/8” x 3” Wedge Anchor 168#661
Rebar Tie - 22g Deck (No Fill) 200# *01 3’
605 Tie Wire Wedge Anchor (1/4" Dia.) 90# Rebar Tie - 22g Deck with LWC 314# *02 6’
606 Tie Wire Spike Anchor (1/4" Dia.) 62# 665 45° Clip and 3/8” x 1-1/2” Hex Bolt (SDI143812 Blue Banger) 314# *03 9’
Steel Connections Load 667 45° Clip and 3/8” x 1-3/4” Hex Bolt ((SDI381258 Blue Banger) 314# *04 12’
620 Loop Connection 314# 668 45° Clip and 3/8” x 1-1/2” Hex Bolt ((PIP143812 Blue Banger) 314# *05 15’
625-1 45° Clip w/ #10 HWH Self Driller (20g) 99# 669 45° Clip and 3/8” x 1-3/4” Hex Bolt ((PIP381258 Blue Banger) 314# *06 18’
625-2 45° Clip w/ #10 HWH Sharp Point (22g) 44# Angle Clip Only Load *07 21’
627-1 45° Clip w/2ea #10 HWH Self Drillers (20g) 198# 682 90° Bracket with 1/4" Anchor Hole N/A *08 24’
627-2 45° Clip w/2ea #10 HWH Sharp Point(20g) 88# 683 90° Bracket with 3/8" Anchor Hole N/A *09 27’
*10 30’
*25 Custom
100
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
77
2
Typical Splay Configuration Inverted Splay Configuration
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Wedgy Pendant Fixture 4 Way Sway SplayFig 772
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the Attachment to Structure. (Listed in column A or on Pages 10-15)B) Select the cable diameter of the Brace Arms.C) Determine the Demand Load at each Connection to Structure. Demand Load = Fixture Weight X 2 (Brace Reaction Load Increase)
Step 2:Confirm that the Demand Load is less than the Cable Assembly Capacity and Attachment to Structure.
Attachment to StructureFastball Capacity
Fixture Wt.Fixture Wt. Fixture Wt.X 1.4 ÷ 2 X 1.4 ÷ 2Demand Load
600-1 Pin and Clip3/32” Cable
145#78#
30# 21#
Variable VariableCapacity Capacity
Example
Confirm that the Demand Load is less than either of these values.
Actual
101
Assembly contains (Splay Arms Only):• ?ea Specified length and dia. of cable• ?ea Wedgys • ?ea Specified quantity of Fastballs
FIG
77
3
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)3) 2ea Fastballs per fixture in the Longitudinal direction and a minimum of 1ea per fixture in the Transverse direction.
• The Fastball restrains 1/16”, 3/32” & 1/8” cable.• The Fastball is quickly installed by inserting the cable into the “V Groove” and tightening a thumb screw. No Tools Required!!!!• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 7 7 3 Fastball Web Sway Bracing System
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Maximum Fixture Weight
1/16” Cable
3/32” Cable
1/8” Cable
32#
78#
130#
A B C D
Attachment to Structure1
CableDiameter
CableLength
# of Fastballs
Per Cable3Concrete Connections AnchorCapacity Wood Connections Anchor
Capacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 500# Angle Clip Only Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 130# 680-1 90° Bracket with 1/4" Anchor Hole N/A *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 541# 680-2 90° Bracket with 3/8" Anchor Hole N/A *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 230# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 150# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 140# *10 30’
Steel Connections Load *25 Custom
620 Loop Connection 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 170#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 170#
A(6**) B C D Qty
Fig 773
Fig 773
Fig 773
A
CB
Qty.Specify
Qty.Specify
Qty.Specify
Qty.Specify
102
Example Layout Wall Connection
Wall Connection
20 LBS LightFixture (TYP)
Transverse Cable
Longitudinal Cable
FASTBALL INSTALLATION INSTRUCTIONSOnce you have inserted the cable into the Fastball twist the wing bolt until it is resting against the cable then turn an additional:
• 1 turn for 1/16” cable• 1‐1/4 turns for 3/32” cable• 1‐1/2 turns for 1/8” cable
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
77
3
FOOTNOTES:1) Attachment Capacities referenced are for a horizontal connection to wall. When brace arms are attached overhead refer to the combined tension and shear capacities shown on the tables on Pages 6‐10.
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Maximum Fixture Weight
1/16” Cable
3/32” Cable
1/8” Cable
32#
78#
130#
Fastball Web Sway Bracing System Fig 773
How to determine the Wedgy Complete Assembly Capacity
Step 1:Select the minimum restraint cable diameter based on the maxweight of each light fixture.
Step 2:A) Determine the capacity of the Attachment to Structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
The following steps must be performed for each different Transverse and Longitudinal scenario.
Demand Load = Fixture Weight X Qty. X 1.4 (Brace Reaction Load Increase)
Step 3:Confirm that the Demand Load is less than the Cable Assembly Capacity and Attachment to Structure.
Attachment to StructureCable Assembly Capacity
Attachment to StructureCable Assembly Capacity
Attachment to StructureCable Assembly Capacity
Fixture Wt.
Fixture Wt. Fixture Wt.
X
X X
X 1.4 =
X 1.4 = X 1.4 =
Demand Load
Demand Load Demand Load
600-1 Pin and Clip3/32” Cable
95#158#
20# 3ea 84#
Variable
Variable Variable
Capacity
Capacity Capacity
Transverse Example
Longitudinal Transverse
Confirm that the Demand Load does not exceed either of these values.
103
Fig 820Rectangular Duct—DSCL23
Lower Attachment
Fig 821Rectangular Duct—2‐Tier
DSCL23 Lower Attachment
Fig 822Rectangular Duct—2‐Tier
DSCU23 Upper Attachment
Fig 823Rectangular Duct—2‐Tier
DSCU23 Upper Attachment
Fig 826Wedgy Rectangular Duct—
Strut Attachment
Fig 824Wedgy Rectangular Duct—DSC
Attachment w/Wedgy
Fig 830Wedgy SWP23 Arms for
Strut Trapeze
Fig 831Wedgy SWP23 Arms for
2‐Tier Strut Trapeze
Fig 825Wedgy Rectangular Duct
Corner Cradle “U” A ttachment
Fig 827Wedgy Rectangular Duct—
2‐Tier Strut Attachment
Fig 828Wedgy Rectangular Duct—
CRC Attachment
Fig 829Wedgy Rectangular Duct—
2‐Tier CRC Attachment
Fig 801Wedgy Flex Duct
Looped with Wedgy Flex Saddle
Fig 802Wedgy Oval and Round
Duct - ”U” Supported
Fig 803Wedgy Round
Duct - ”U” Supported
Fig 800Wedgy Round DuctLooped Connection
Fig. 800-802 Wedgy Round HVAC Supports
Fig. 820-831 Wedgy Rectangle HVAC Supports
Product Index - Wedgy 800 Series Cable Supports
H V A C S o l u t i o n s
80
0 S
ER
IES
104
80
0 S
ER
IES
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Fig. 870-872 Wedgy HVAC Equipment Supports
HVAC cable support solutions for suspending ducts, registers and mechanical equipment are not only safe and easy to install, but also SMACNA research tested.
CEAS HVAC cable supports are used by professionals across the construction industry worldwide.
Complete Attachment Solutions:
STEELMETAL
Fig. 850-856 Wedgy HVAC Fixture Supports
Fig 850Ceiling Mtd Register with
Common 2‐way Safety Cables
Fig 851Ceiling Mtd Register with
Common 2‐way SafetyCables & Flex Support
Fig 855Ceiling Mounted Register
with 1 Safety Cable
Fig 856Ceiling Mounted Register
with 2 Safety Cables
Fig 870Wedgy Mechanical
Equipment - DSCL23 LowerAttachment
Fig 871Wedgy Mechanical
Equipment - DSCU23 UpperAttachment
Fig 872Wedgy MechanicalEquipment - DSC
Attachment with Wedgy
105
FIG
80
0
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 1ea Cable arm with selected anchor• 1ea Wedgy
• Provides support for Round Duct up to 36”• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 0 0 Wedgy Round Duct—Looped Connection
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A(6**) B C Qty
Fig 800
Fig 800
Fig 800
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A
CB
106
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
80
0
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Dimension A must be at least 1/4 of the duct diameter. Example: 12” Duct—Dimension A = 4”
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
Cable Assembly Capacity (Per Cable)
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
Variable Variable
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
95#158#95#
Capacity Capacity
Wedgy Round Duct—Looped ConnectionFig 800
Refer to pages 172-173 for duct weights to determine support spacing requirements
Refer to page GN‐5 for cable lengths
DROPLENGTH
ROUND DUCT36” & SMALLER
DIMENSION “A”1/4” OF DUCT DIAMETER
Fig 800 used as a sway brace location
107
FIG
80
1
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 1ea Cable arm with selected anchor• 1ea Wedgy• 1ea Plastic Flex Saddle
• Provides support for Flexible Duct• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 0 1 Wedgy Flex Duct - Looped withWedgy Flex Saddle
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A B C D
Attachment to Structure1
CableDiameter
CableLength
PlasticLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’ *01 5” - 6" Flex FS12
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’ *02 7” - 10" Flex FS18
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’ *03 12” - 14" Flex FS24
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’ *04 16” - 18" Flex FS31
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’ *25 Custom Length
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C D Qty
Fig 801
Fig 801
Fig 801
A
C DB
108
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
80
1
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Flex Duct—Looped with Wedgy Flex SaddleFig 801
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
Cable Assembly Capacity (Per Cable)
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
Variable Variable
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
95#158#95#
Capacity Capacity
Refer to pages 172-173 for duct weights to determine support spacing requirements
109
FIG
80
2
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 1ea Cable arm with selected anchor• 1ea Selected anchor without cable• 1ea Wedgy
• Provides support for Oval or Round Duct• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 0 2 Wedgy Oval and Round Duct—”U” Supported
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A(6**) B C Qty
Fig 802
Fig 802
Fig 802
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A
CB
110
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
80
2
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Oval and Round Duct—”U” SupportedFig 802
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
Cable Assembly Capacity (Per Cable)
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
Variable Variable
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
95#158#95#
Capacity Capacity
Refer to pages 172-173 for duct weights to determine support spacing requirements
111
FIG
80
3
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Assembly contains:• 2ea Cable arms with selected anchors • 2ea Wedgys • 1ea “U” Support
• Provides support for Round Duct• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 0 3 Wedgy Round Duct—”U” Supported
A B C D
Attachment to Structure1
CableDiameter
CableLength
DuctDiameterConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C D Qty
Fig 803
Fig 803
Fig 803
A
C
D
B
112
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
80
3
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Round Duct—”U” SupportedFig 803
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity
Cable Assembly Capacity (Per Cable)
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Refer to pages 172-173 for duct weights to determine support spacing requirements
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
95#158#
190#316#190#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
113
FIG
82
0
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable arms with selected anchors • 2ea DSCL Clips
• Provides support for Rectangular Duct up to 60” wide per SMACNA• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 2 0 Rectangular Duct—DSCL Lower Attachment
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A(6**) B C Qty
Fig 820
Fig 820
Fig 820
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
4ea #10 screws must be installed in each clip
Cable Assembly Capacity
3/32” Cable
1/8” Cable173#
346# per set
Capacities are based on tests performed into a minimum of 24g duct.
A
CB
Qty.2ea
114
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
82
0
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Rectangular Duct—DSCL Lower AttachmentFig 820
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
When cables are not attached vertical refer to page GN‐1 for the appropriate reductions that must be taken for the attachment to Structure.
OUTBOUND VERTICAL
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
95#173#
190#346#190#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Cable Assembly Capacity
3/32” Cable
1/8” Cable173#
346# per set
Capacities are based on tests performed into a minimum of 24g duct.
115
FIG
82
1
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable arms with selected anchors • 4ea DSCL Clips
• Provides support for Rectangular Duct up to 60” wide per SMACNA• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 2 1 Rectangular Duct - 2 Tier DSCL Lower Attachment
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A(6**) B C Qty
Fig 821
Fig 821
Fig 821
4ea #10 screws must be installed in each clip
Cable Assembly Capacity
3/32” Cable
1/8” Cable173#
346# per set
Capacities are based on tests performed into a minimum of 24g duct.
A
CB
Qty.2ea
Qty.4ea
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
116
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
82
1
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Rectangular Duct - 2 Tier DSCL Lower AttachmentFig 821
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 6‐102) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
95#173#
190#346#190#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Cable Assembly Capacity
3/32” Cable
1/8” Cable173#
346# per set
Capacities are based on tests performed into a minimum of 24g duct.
117
FIG
82
2
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable arms with selected anchors • 2ea DSCU Brackets
• Provides support for Rectangular Duct up to 60” wide per SMACNA• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 2 2 Rectangular Duct - DSCU Upper Attachment
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A(6**) B C Qty
Fig 822
Fig 822
Fig 822
Cable Assembly Capacity
3/32” Cable
1/8” Cable103#
206# per set
Capacities are based on tests performed into a minimum of 24g duct.
4ea #10 screws must be installed in each clip
A
CB
Qty.2ea
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
118
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
82
2
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Rectangular Duct - DSCU Upper AttachmentFig 822
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 6‐102) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Cable Assembly Capacity
3/32” Cable
1/8” Cable103#
206# per set
Capacities are based on tests performed into a minimum of 24g duct.
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
95#103#
190#206#190#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
When cables are not attached vertical refer to page GN‐1 for the appropriate reductions that must be taken for the attachment to Structure.
OUTBOUND INBOUND VERTICAL
119
FIG
82
3
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable arms with selected anchors • 4ea DSCU Brackets
• Provides support for Rectangular Duct up to 60” wide per SMACNA• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 2 3 Rectangular Duct - 2-Tier DSCU Upper Attachment
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A(6**) B C Qty
Fig 823
Fig 823
Fig 823
Cable Assembly Capacity
3/32” Cable
1/8” Cable103#
206# per set
Capacities are based on tests performed into a minimum of 24g duct.
4ea #10 screws must be installed in each clip
A
CB
Qty.2ea
Qty.4ea
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
120
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
82
3
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Rectangular Duct - 2-Tier DSCU Upper AttachmentFig 823
How to determine the Wedgy Complete Assembly Capacity1
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
FOOTNOTES:1) Capacities noted are for each individual tier of the ductwork. The total Weight per Linear Foot of the utility for each tier must be calculated and can not exceed the capacity of the attachment to structure.
Cable Assembly Capacity
3/32” Cable
1/8” Cable103#
206# per set
Capacities are based on tests performed into a minimum of 24g duct.
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
95#103#
190#206#190#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
121
FIG
82
4
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable arms with selected anchors• 2ea Wedgys • 2ea DSC Clips
• Provides support for Rectangular Duct up to 60” wide per SMACNA• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 2 4 Wedgy Rectangular Duct - DSC Attachment w/Wedgy
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A(6**) B C Qty
Fig 824
Fig 824
Fig 824
Cable Assembly Capacity
Lower Upper3/32” Cable
1/8” Cable173#
346# per set103#
206# per set
Capacities are based on tests performed into a minimum of 24g duct.
4ea #10 screws must be installed in each clip
A
CB
Qty.2ea
Qty.2ea
Qty.2ea
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
122
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
82
4
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Rectangular Duct - DSC Attachment w/Wedgy Fig 824
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
Cable Assembly Capacity
Lower Upper3/32” Cable
1/8” Cable173#
246# per set103#
206# per set
Capacities are based on tests performed into a minimum of 24g duct.
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
95#103#
190#206#190#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
When cables are not attached vertical refer to page GN‐1 for the appropriate reductions that must be taken for the attachment to Structure.
Outbound—Upper Attachment
Outbound—Lower Attachment
Vertical—Upper Attachment
Vertical—Lower Attachment
Inbound—Upper Attachment
123
FIG
82
5
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 1ea Cable arm with selected anchor • 1ea Selected anchor without cable • 1ea Wedgy • 2ea Corner Cradle
• Provides support for Rectangular Duct• Ideal for Phenolic Ductwork• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 2 5 Wedgy Rectangular Duct - Corner Cradle “U” Attachment
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A(6**) B C Qty
Fig 825
Fig 825
Fig 825
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A
CB
Qty.2ea
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
124
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
82
5
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Rectangular Duct - Corner Cradle “U” Attachment Fig 825
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
Attachment to StructureCable Assembly Capacity
X 2 = X 2 =600-1 Pin and Clip3/32” Cable
95# 190#158#158#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
125
FIG
82
6
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable assemblies with selected anchors• 1ea Strut Trapeze with single Wedgys pressed in
• Provides support for Rectangular Duct• Selected strut trapeze comes cut to length with Wedgys pressed in• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on thenext page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 2 6 Wedgy Rectangular Duct - Strut Attachment
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A B C D E
Attachment to Structure1
CableDiameter
CableLength Width Strut Type
Concrete Connections AnchorCapacity Wood Connections Anchor
Capacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
*01
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
*02
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
*03
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Strut Capacities (Duct @ 6” max from cable)
Width (Inch)1-5/8" Strut
(Lbs)1-5/8" Strut
B2B(Lbs)3-1/4" Strut
(Lbs)24 1090 3000 335036 910 2550 280048 780 2200 240060 685 1900 210072 600 1700 187084 400 1500 1680
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
12g PHD1001
12g PHD1001A
12g PHD1501
1-5/8”
3-1/4”
3-1/4”
Cable Assembly Capacity
3/32” Cable
1/8” Cable
125#
231#
A(6**) B C D E Qty
Fig 826
Fig 826
Fig 826
A
CB
D
E
.75”
6” Max if Exceeded ContactCEAS For New Capacity
126
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
82
6
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Rectangular Duct—Strut Attachment Fig 826
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
C) Determine the Trapeze Capacity.
Step 2:The lessor of the 3 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
Attachment to StructureCable Assembly CapacityTrapeze Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable33” Wide with 1-5/8” Strut
73#125#
146#250#910#146#
Variable VariableCapacity CapacityExample
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Strut Capacities (Duct @ 6” max from cable)
Width (Inch)1-5/8" Strut
(Lbs)1-5/8" Strut
B2B(Lbs)3-1/4" Strut
(Lbs)24 1090 3000 335036 910 2550 280048 780 2200 240060 685 1900 210072 600 1700 187084 400 1500 1680
Cable Assembly Capacity
3/32” Cable
1/8” Cable
125#
231#
127
FIG
82
7
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable assemblies with selected anchors• 2ea Strut Trapeze with single Wedgys pressed in
• Provides support for Rectangular Duct• Selected strut trapeze comes cut to length with Wedgys pressed in• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 2 7 Wedgy Rectangular Duct - 2-Tier Strut Attachment
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A B C D E
Attachment to Structure1
CableDiameter
CableLength Width Strut Type
Concrete Connections AnchorCapacity Wood Connections Anchor
Capacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
*01
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
*02
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
*03
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Strut Capacities (Duct @ 6” max from cable)
Width (Inch)1-5/8" Strut
(Lbs)1-5/8" Strut
B2B(Lbs)3-1/4" Strut
(Lbs)24 1090 3000 335036 910 2550 280048 780 2200 240060 685 1900 210072 600 1700 187084 400 1500 1680
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
12g PHD1001
12g PHD1001A
12g PHD1501
1-5/8”
3-1/4”
3-1/4”
Cable Assembly Capacity
3/32” Cable
1/8” Cable
125#
231#
A(6**) B C D E Qty
Fig 827
Fig 827
Fig 827
A
C
B
D
E
.75”
6” Max if Exceeded ContactCEAS For New Capacity
128
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
82
7
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Rectangular Duct - 2-Tier Strut Attachment Fig 827
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
C) Determine the Trapeze Capacity.
Step 2:The lessor of the 3 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
Attachment to StructureCable Assembly CapacityTrapeze Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable33” Wide with 1-5/8” Strut
73#125#
146#250#910#146#
Variable VariableCapacity CapacityExample
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Strut Capacities (Duct @ 6” max from cable)
Width (Inch)1-5/8" Strut
(Lbs)1-5/8" Strut
B2B(Lbs)3-1/4" Strut
(Lbs)24 1090 3000 335036 910 2550 280048 780 2200 240060 685 1900 210072 600 1700 187084 400 1500 1680
Cable Assembly Capacity
3/32” Cable
1/8” Cable
125#
231#
129
FIG
82
8
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable assemblies with selected anchors• 1ea CRC Trapeze with single Wedgys pressed in
• Provides support for Rectangular Duct• CRC trapeze comes cut to length with Wedgys pressed in• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 2 8 Wedgy Rectangular Duct - CRC Attachment
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A B C D
Attachment to Structure1
CableDiameter
CableLength Width
Concrete Connections AnchorCapacity Wood Connections Anchor
Capacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Trapeze Capacity (Duct @ 6” max from cable)
Width (Inch) Load (Lbs)18 13524 12036 10048 75
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
Cable Assembly Capacity
3/32” Cable
1/8” Cable112#
A(6**) B C D E Qty
Fig 828
Fig 828
Fig 828
A
C
B
D
.75”
6” Max if Exceeded ContactCEAS For New Capacity
130
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
82
8
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Rectangular Duct - CRC AttachmentFig 828
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
C) Determine the Trapeze Capacity.
Step 2:The lessor of the 3 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
Attachment to StructureCable Assembly CapacityTrapeze Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable22” Wide Trapeze
95#112#
190#224#120#120#
Variable VariableCapacity CapacityExample
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Trapeze Capacity (Duct @ 6” max from cable)
Width (Inch) Load (Lbs)18 13524 12036 10048 75
Cable Assembly Capacity
3/32” Cable
1/8” Cable112#
131
FIG
82
9
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
• Provides support for Rectangular Duct• CRC trapeze comes cut to length with Wedgys pressed in• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 2 9 Wedgy Rectangular Duct - 2-Tier CRC Attachment
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-152) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A B C D
Attachment to Structure1
CableDiameter
CableLength Width
Concrete Connections AnchorCapacity Wood Connections Anchor
Capacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Trapeze Capacity (Duct @ 6” max from cable)
Width (Inch) Load (Lbs)18 13524 12036 10048 75
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
Cable Assembly Capacity
3/32” Cable
1/8” Cable112#
A(6**) B C D E Qty
Fig 829
Fig 829
Fig 829
A
C
B
D
.75”
6” Max if Exceeded ContactCEAS For New Capacity
132
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
82
9
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Rectangular Duct - 2-Tier CRC AttachmentFig 829
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
C) Determine the Trapeze Capacity.
Step 2:The lessor of the 3 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
FOOTNOTES:1) Capacities noted are for each individual tier of the trapeze. The total Weight per Linear Foot of the utility for each tier must be calculated and can not exceed the capacity of the attachment to structure.
Attachment to StructureCable Assembly CapacityTrapeze Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable22” Wide Trapeze
95#112#
190#224#120#120#
Variable VariableCapacity CapacityExample
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Trapeze Capacity (Duct @ 6” max from cable)
Width (Inch) Load (Lbs)18 13524 12036 10048 75
Cable Assembly Capacity
3/32” Cable
1/8” Cable112#
133
FIG
83
0
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable assemblies with selected anchors• 2ea single Wedgys pressed in
• Designed for punched or slotted strut• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 3 0 Single Wedgy Arm for Strut Trapeze
FOOTNOTES:1) Ultimate capacities have been reduced to take into consideration eccentric loads on the trapeze 2) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 3) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A(6**) B C Qty
Fig 830
Fig 830
Fig 830
A B C
Attachment to Structure2
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)3 73# 640-1 Wood Eyelag - 1/4” x 3” 208# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)3 42# 640-2 Wood Eyelag - 1/4” x 4” 208# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)3 72# 640-3 Wood Eyelag - 1/4” x 5” 208# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 119# 641 Timberpin 77# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 84# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 165#660
Pigtail Loop - 20g Deck (No Fill) 102# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 231# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 200#661
Rebar Tie - 22g Deck (No Fill) 154# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 77# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 53# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 112# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 96# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 96# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 231# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 154# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 80#
624-2 90° Clip and #10 HWH Sharp Point (22g) 35#
628 Snaphook for 1/4" Hole 77#
Cable Assembly Capacity1
3/32” Cable
1/8” Cable
126#
223#
A
CB
Qty.2ea
134
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
83
0
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Single Wedgy Arm for Strut TrapezeFig 830
How to determine the Wedgy Complete Assembly Capacity1
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
FOOTNOTES:1) Capacties shown are for the cable assembly and attachment to structure only. The trapeze is not taken into consideration.2) Capacities are reduced to account for the potential of eccentric loading on trapezes
Cable Assembly Capacity2
3/32” Cable
1/8” Cable
126#
223#
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
73#126#
146#252#146#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
135
FIG
83
1
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable assemblies with selected anchors• 4ea single Wedgys pressed in
• Designed for punched or slotted strut• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 3 1 Single Wedgy Arm for 2-Tier Strut Trapeze
FOOTNOTES:1) Ultimate capacities have been reduced to take into consideration eccentric loads on the trapeze 2) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 3) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A(6**) B C Qty
Fig 831
Fig 831
Fig 831
Cable Assembly Capacity1
3/32” Cable
1/8” Cable
126#
223#
A
CB
Qty.2ea
Qty.4ea
A B C
Attachment to Structure2
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)3 73# 640-1 Wood Eyelag - 1/4” x 3” 208# *02 3/32" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)3 42# 640-2 Wood Eyelag - 1/4” x 4” 208# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)3 72# 640-3 Wood Eyelag - 1/4” x 5” 208# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 119# 641 Timberpin 77# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 84# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 165#660
Pigtail Loop - 20g Deck (No Fill) 102# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 231# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 200#661
Rebar Tie - 22g Deck (No Fill) 154# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 77# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 53# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 112# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 96# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 96# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 231# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 154# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 80#
624-2 90° Clip and #10 HWH Sharp Point (22g) 35#
628 Snaphook for 1/4" Hole 77#
136
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
83
1
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Single Wedgy Arm for 2-Tier Strut TrapezeFig 831
How to determine the Wedgy Complete Assembly Capacity1, 2
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Refer to pages 172-173 for duct weights to determine support spacing requirements
FOOTNOTES:1) Capacities noted are for each individual tier of the trapeze. The total Weight per Linear Foot of the utility for each tier must be calculated and can not exceed the capacity of the attachment to structure. 2) Capacties shown are for the cable assembly and attachment to structure only. The trapeze is not taken into consideration.3) Capacities are reduced to account for the potential of eccentric loading on trapezes
Cable Assembly Capacity3
3/32” Cable
1/8” Cable
126#
223#
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
73#126#
146#252#146#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
137
FIG
85
0
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 1ea Assembly with 2ea cable arms connected to 1ea selected anchors• 2ea Wedgys
• Designed as a support for ceiling mounted Registers• 2 cables are connected to a single anchor minimizing the number of attachments• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 5 0 Ceiling Mtd Regiter with Common 2-way Safety Cables
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A(6**) B C Qty
Fig 850
Fig 850
Fig 850
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A
C
B
Qty.2ea
138
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
85
0
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Ceiling Mtd Regiter with Common 2‐way Safety CablesFig 850
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
Variable Variable
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
95#158#95#
Capacity Capacity
139
FIG
85
1
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 1ea Assembly with 3ea cable arms connected to 1ea selected anchors• 3ea Wedgys• 1ea Plastic Flex Saddle
• Designed as a support for ceiling mounted Registers and Flex Support• 3 cables are connected to a single anchor minimizing the number of attachments• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 5 1 Ceiling Mtd Register with Common 2-way Safety Cables & Flex Support
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A B C D
Attachment to Structure1
CableDiameter
CableLength
PlasticLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’ *01 5” - 6" Flex FS12
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’ *02 7” - 10" Flex FS18
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’ *03 12” - 14" Flex FS24
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’ *04 16” - 18" Flex FS31
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’ *25 Custom Length
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C D Qty
Fig 851
Fig 851
Fig 851
A
C
B
D
Qty.3ea
140
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
85
1
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Ceiling Mtd Register with Common 2‐way Safety Cables & Flex SupportFig 851
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
Variable Variable
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
95#158#95#
Capacity Capacity
141
FIG
85
5
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 1ea Cable arm with selected anchor• 1ea Wedgys
• Designed as a support for ceiling mounted Registers • Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 5 5 Ceiling Mounted Register with 1 Safety Cable
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A(6**) B C Qty
Fig 855
Fig 855
Fig 855
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A
CB
142
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
85
5
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Ceiling Mounted Register with 1 Safety Cable Fig 855
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
Variable Variable
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
95#158#95#
Capacity Capacity
143
FIG
85
6
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable arm with selected anchor• 2ea Wedgys
• Designed as a support for ceiling mounted Registers • Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 5 6 Ceiling Mounted Register with 2 Safety Cables
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A(6**) B C Qty
Fig 856
Fig 856
Fig 856
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A
CB
Qty.2ea
144
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
85
6
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Ceiling Mounted Register with 2 Safety Cables Fig 856
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
Variable Variable
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
95#158#95#
Capacity Capacity
145
FIG
87
0
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2, 4 or 6 Cable arms with selected anchors • 2, 4 or 6 DSCL Brackets
• Provides support for Mechanical Equipment• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 7 0 Mechanical Equipment - DSCL Lower Attachment
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A B C D
Attachment to Structure1
CableDiameter
CableLength
How Many DSCL Brackets?Concrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’ *02 2 Brackets
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’ *04 4 Brackets
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’ *06 6 Brackets
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C D Qty
Fig 870
Fig 870
Fig 870 Capacities are based on tests performed into a minimum of 24g duct.
Cable Assembly Capacity per Bracket
3/32” Cable
1/8” Cable173#
346# per set of 2
4ea #10 screws must be installed in each bracket
A
CB
Qty.Specify
146
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
87
0
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Mechanical Equipment - DSCL Lower AttachmentFig 870
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by the number of support arms. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by the number of DSCL Brackets being used.
When cables are not attached vertical refer to page GN‐1 for the appropriate reductions that mustbe taken for the Attachment to Structure.
Mechanical Unit Supported with 4ea DSCL Brackets
Capacities are based on tests performed into a minimum of 24g duct.
Cable Assembly Capacity per Bracket
3/32” Cable
1/8” Cable173#
346# per set of 2
Refer to pages 172-173 for duct weights to determine support spacing requirements
Attachment to StructureCable Assembly Capacity
X 4 =X 4 =
X =X =
600-1 Pin and Clip3/32” Cable
95#173#
380#692#380#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
147
FIG
87
1
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2, 4 or 6 Cable arms with selected anchors • 2, 4 or 6 DSCU Brackets
• Provides support for Mechanical Equipment• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 7 1 Mechanical Equipment - DSCU Upper Attachment
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A(6**) B C D Qty
Fig 871
Fig 871
Fig 871 Capacities are based on tests performed into a minimum of 24g duct.
Cable Assembly Capacity per Bracket
3/32” Cable
1/8” Cable103#
206# per set of 2
4ea #10 screws must be installed in each bracket
A
CB
Qty.Specify
A B C D
Attachment to Structure1
CableDiameter
CableLength
How Many DSCU Brackets?Concrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’ *02 2 Brackets
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’ *04 4 Brackets
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’ *06 6 Brackets
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
148
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
87
1
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Mechanical Equipment - DSCU Upper AttachmentFig 871
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by the number of support arms. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by the number of DSCU Brackets being used.
When cables are not attached vertical refer to page GN‐1 for the appropriate reductions that mustbe taken for the Attachment to Structure.
Mechanical Unit Supported with 4ea DSCU Brackets
Capacities are based on tests performed into a minimum of 24g duct.
Cable Assembly Capacity per Bracket
3/32” Cable
1/8” Cable103#
206# per set of 2
Refer to pages 172-173 for duct weights to determine support spacing requirements
Attachment to StructureCable Assembly Capacity
X 4 =X 4 =
X =X =
600-1 Pin and Clip3/32” Cable
95#103#
380#412#380#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
149
FIG
87
2
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2, 4 or 6 Cable arms with selected anchors• 2, 4 or 6 Wedgys• 2, 4 or 6 DSC Brackets
• Provides support for Mechanical Equipment• Quick installation and adjustment• No tools required for adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• SMACNA Testing and Research Institute verified • Manufactured to ASTM A1023 and ASTM A931
F i g . 8 7 2 Mechanical Equipment - DSC Attachmentwith Wedgy
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A B C D
Attachment to Structure1
CableDiameter
CableLength
How Many DSC Brackets?Concrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’ *02 2 Brackets
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’ *04 4 Brackets
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’ *06 6 Brackets
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C D Qty
Fig 872
Fig 872
Fig 872
4ea #10 screws must be installed in each bracket
Cable Assembly Capacity
Lower Upper3/32” Cable
1/8” Cable173#
346# per set103#
206# per set
Capacities are based on tests performed into a minimum of 24g duct.
A
C
B
Qty.Specify
150
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
87
2
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Mechanical Equipment - DSC Attachment with WedgyFig 872
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by the number of support arms. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by the number of DSCU Brackets being used.
When cables are not attached vertical refer to page GN‐1 for the appropriate reductions that mustbe taken for the Attachment to Structure.
Mechanical Unit Supported with 4ea DSC Brackets
Refer to pages 172-173 for duct weights to determine support spacing requirements
Attachment to StructureCable Assembly Capacity
X 4 =X 4 =
X =X =
600-1 Pin and Clip3/32” Cable
95#103#
380#412#380#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Cable Assembly Capacity
Lower Upper3/32” Cable
1/8” Cable173#
346# per set103#
206# per set
Capacities are based on tests performed into a minimum of 24g duct.
151
P l u m b i n g / P i p i n g & M e c h a n i c a l
00
0 S
ER
IES
Fig. 900-901 Wedgy Plumbing/Piping Single Hung Cable Supports
Fig. 926-931 Wedgy Plumbing/Piping Trapeze Supports
Fig. 957 Wedgy Chilled Beam Support
Product Index - Wedgy 900 Series Cable Supports
Fig 926Wedgy Strut
Trapeze
Fig 900Wedgy Single Hung
Pipe Support
Fig 901Wedgy Single Hung Pipe Support
with Clevis Hanger
Fig 902Wedgy Single Hung Pipe Support
with J-Hanger
Fig 957Wedgy Chilled Beam Support
Fig 927Wedgy 2‐Tier Strut Trapeze
Fig 930Single Wedgy Arms
for Strut Trapeze
Fig 931Single Wedgy Arms
for 2‐Tier Strut Trapeze
152
STEELMETAL
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Wedgy cable supports solutions are engineered to suspend all types of pipework, pipe trapeze and chilled beams quick and easy. Pre-assembled supports eliminate the need for preparation or additional tools.
Wedgy cable supports are the choice of construction professionals world wide becasue they install quick and easy saving you time and money.
Complete Attachment Solutions:
153
FIG
90
0
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 1ea Cable assembly with selected anchor• 1ea Loop Hanger with Single Wedgy pressed in
• Provides support for Pipe• Felted hangers available for Copper• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 9 0 0 Wedgy Single Hung Pipe Supportwith Loop Hanger
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A B C D
Attachment to Structure1
CableDiameter
CableLength Loop Hanger Size
Concrete Connections AnchorCapacity Wood Connections Anchor
Capacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’ *01 1/2”
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’ *02 3/4”
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’ *03 1”
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’ *04 1-1/4”
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’ *05 1-1/2”
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’ *06 2”
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’ *07 2-1/2”
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’ *08 3”
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’ *09 3-1/2”
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’ *10 4”
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
A(6**) B C D Qty
Fig 900
Fig 900
Fig 900
Cable Assembly Capacity
3/32” Cable
1/8” Cable
163#
300#
Note: For felted loop hangers add an“F” to the D order option.Example: 03 = 1” Loop Hanger 03F = 1” Felted Loop Hanger*Order the next larger size to allowfor the thickness of the felt lining.
A
C
B
D
154
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
90
0
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Single Hung Pipe Support with Loop HangerFig 900
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity.
Refer to page 174 for pipe weights to determine support spacing requirements
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Cable Assembly Capacity
3/32” Cable
1/8” Cable
163#
300#
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
Variable Variable
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
95#163#95#
Capacity Capacity
155
A B C D
Attachment to Structure1
CableDiameter
CableLength Loop Hanger Size
Concrete Connections AnchorCapacity Wood Connections Anchor
Capacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’ *01 1/2”
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’ *02 3/4”
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’ *03 1”
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’ *04 1-1/4”
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’ *05 1-1/2”
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’ *06 2”
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’ *07 2-1/2”
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’ *08 3”
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’ *09 3-1/2”
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’ *10 4”
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
FIG
90
1
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 1ea Cable assembly with selected anchor• 1ea Clevis Hanger with Single Wedgy pressed in
• Provides support for Pipe• Felted hangers available for Copper• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 9 0 1 Wedgy Single Hung Pipe Supportwith Clevis Hanger
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Note: For felted loop hangers add an“F” to the D order option.Example: 03 = 1” Loop Hanger 03F = 1” Felted Loop Hanger*Order the next larger size to allowfor the thickness of the felt lining.
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A(6**) B C D Qty
Fig 901
Fig 901
Fig 901
Cable Assembly Capacity
3/32” Cable
1/8” Cable
163#
300#
A
C
B
D
156
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
90
1
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Single Hung Pipe Support with Clevis HangerFig 901
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity.
Refer to page 174 for pipe weights to determine support spacing requirements
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Cable Assembly Capacity
3/32” Cable
1/8” Cable
163#
300#
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
Variable Variable
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
95#163#95#
Capacity Capacity
157
FIG
90
2
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 1ea Cable assembly with selected anchor• 1ea J-Hanger with Single Wedgy pressed in
• Provides support for Pipe• Felted hangers available for Copper• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 9 0 2 Wedgy Single Hung Pipe Supportwith J-Hanger
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A(6**) B C D Qty
Fig 902
Fig 902
Fig 902
Cable Assembly Capacity
3/32” Cable
1/8” Cable
163#
300#
A
C
B
D
A B C D
Attachment to Structure1
CableDiameter
CableLength Loop Hanger Size
Concrete Connections AnchorCapacity Wood Connections Anchor
Capacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *02 3/32" Cable *01 3’ *01 1/2”
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *03 1/8" Cable *02 6’ *02 3/4”
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 9’ *03 1”
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’ *04 1-1/4”
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’ *05 1-1/2”
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’ *06 2”
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’ *07 2-1/2”
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’ *08 3”
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’ *09 3-1/2”
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’ *10 4”
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Note: For felted loop hangers add an“F” to the D order option.Example: 03 = 1” Loop Hanger 03F = 1” Felted Loop Hanger*Order the next larger size to allowfor the thickness of the felt lining.
158
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
90
2
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Single Hung Pipe Support with J-HangerFig 902
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity.
Refer to page 174 for pipe weights to determine support spacing requirements
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Cable Assembly Capacity
3/32” Cable
1/8” Cable
163#
300#
Attachment to StructureCable Assembly Capacity
600-1 Pin and Clip3/32” Cable
Variable Variable
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
95#163#95#
Capacity Capacity
159
FIG
92
6
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable assemblies with selected anchors• 1ea Strut Trapeze with Single Wedgys pressed in
• Provides support for Pipe• Prefabricated trapezes save time and money• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 9 2 6 Wedgy Strut Trapeze
FOOTNOTES:1) Ultimate capacities have been reduced to take into consideration eccentric loads on the trapeze 2) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A B C D E
Attachment to Structure2
CableDiameter
CableLength
CRCWidth
ConduitSize4Concrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)3 73# 640-1 Wood Eyelag - 1/4” x 3” 208# *02 3/32" Cable *01 3’
*01
600-2 Powers Pin & Clip (7/8” Embed.)3 42# 640-2 Wood Eyelag - 1/4” x 4” 208# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)3 72# 640-3 Wood Eyelag - 1/4” x 5” 208# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 119# 641 Timberpin 77# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 84# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 165#660
Pigtail Loop - 20g Deck (No Fill) 102# *06 18’
*02
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 231# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 200#661
Rebar Tie - 22g Deck (No Fill) 154# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 77# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 53# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
*03
620 Loop Connection 112# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 96# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 96# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 231# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 154# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 80#
624-2 90° Clip and #10 HWH Sharp Point (22g) 35#
628 Snaphook for 1/4" Hole 77#
Strut Capacities
Width14g 13/16"
Strut
14g 13/16" Back to Back
Strut
12g 1-5/8" Strut
24” 185# 495# 650#
36" 120# 330# 450#
48" 65# 245# 340#
60" 40# 195# 275#
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
14g PHD1301
14g PHD1301A
12g PHD1001
Cable Assembly Capacity1
3/32” Cable
1/8” Cable
125#
231#
A(6**) B C D E Qty
Fig 926
Fig 926
Fig 926
A
C
B
D
E
.75”
160
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
92
6
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Strut TrapezeFig 926
How to determine the Wedgy Complete Assembly Capacity
Strut Capacities
Width14g 13/16"
Strut
14g 13/16" Back to Back
Strut
12g 1-5/8" Strut
24” 185# 495# 650#
36" 120# 330# 450#
48" 65# 245# 340#
60" 40# 195# 275#
Attachment to StructureCable Assembly CapacityTrapeze Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable33” Wide with 1-5/8” Strut
73#125#
146#250#450#146#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
FOOTNOTES:
1) Capacities are reduced to account for the potential of eccentric loading on trapezes
Refer to page 174 for pipe weights to determine support spacing requirements
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
C) Determine the Trapeze Capacity.
Step 2:The lessor of the 3 values is the Wedgy Complete Assembly Capacity
Cable Assembly Capacity 1
3/32” Cable
1/8” Cable
125#
231#
161
FIG
92
7
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable assemblies with selected anchors• 2ea Strut Trapeze with Single Wedgys pressed in
• Provides support for Pipe• Prefabricated trapezes save time and money• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 9 2 7 Wedgy 2-Tier Strut Trapeze
FOOTNOTES:1) Ultimate capacities have been reduced to take into consideration eccentric loads on the trapeze 2) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
A B C D E
Attachment to Structure2
CableDiameter
CableLength
CRCWidth
ConduitSize4Concrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)3 73# 640-1 Wood Eyelag - 1/4” x 3” 208# *02 3/32" Cable *01 3’
*01
600-2 Powers Pin & Clip (7/8” Embed.)3 42# 640-2 Wood Eyelag - 1/4” x 4” 208# *03 1/8" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)3 72# 640-3 Wood Eyelag - 1/4” x 5” 208# *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 119# 641 Timberpin 77# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 84# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 165#660
Pigtail Loop - 20g Deck (No Fill) 102# *06 18’
*02
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 231# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 200#661
Rebar Tie - 22g Deck (No Fill) 154# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 77# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 53# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
*03
620 Loop Connection 112# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 96# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 96# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 231# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 154# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 80#
624-2 90° Clip and #10 HWH Sharp Point (22g) 35#
628 Snaphook for 1/4" Hole 77#
Strut Capacities
Width14g 13/16"
Strut
14g 13/16" Back to Back
Strut
12g 1-5/8" Strut
24” 185# 495# 650#
36" 120# 330# 450#
48" 65# 245# 340#
60" 40# 195# 275#
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
14g PHD1301
14g PHD1301A
12g PHD1001
Cable Assembly Capacity1
3/32” Cable
1/8” Cable
125#
231#
A(6**) B C D E Qty
Fig 927
Fig 927
Fig 927
A
C
B
D
E
.75”
162
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
92
7
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy 2-Tier Strut TrapezeFig 927
How to determine the Wedgy Complete Assembly Capacity
Strut Capacities
Width14g 13/16"
Strut
14g 13/16" Back to Back
Strut
12g 1-5/8" Strut
24” 185# 495# 650#
36" 120# 330# 450#
48" 65# 245# 340#
60" 40# 195# 275#
Attachment to StructureCable Assembly CapacityTrapeze Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable33” Wide with 1-5/8” Strut
73#125#
146#250#450#146#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
FOOTNOTES:
1) Capacities are reduced to account for the potential of eccentric loading on trapezes
Refer to page 174 for pipe weights to determine support spacing requirements
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
C) Determine the Trapeze Capacity.
Step 2:The lessor of the 3 values is the Wedgy Complete Assembly Capacity
Cable Assembly Capacity 1
3/32” Cable
1/8” Cable
125#
231#
163
FIG
93
0
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable assemblies with selected anchors• 2ea Single Wedgys
F i g . 9 3 0 Single Wedgy Arms for Strut Trapeze
FOOTNOTES:1) Ultimate capacities have been reduced to take into consideration eccentric loads on the trapeze 2) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 3) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A(6**) B C Qty
Fig 930
Fig 930
Fig 930
A B C
Attachment to Structure2
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)3 73# 640-1 Wood Eyelag - 1/4” x 3” 208# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)3 42# 640-2 Wood Eyelag - 1/4” x 4” 208# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)3 72# 640-3 Wood Eyelag - 1/4” x 5” 208# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 119# 641 Timberpin 77# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 84# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 165#660
Pigtail Loop - 20g Deck (No Fill) 102# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 231# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 200#661
Rebar Tie - 22g Deck (No Fill) 154# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 77# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 53# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 112# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 96# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 96# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 231# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 154# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 80#
624-2 90° Clip and #10 HWH Sharp Point (22g) 35#
628 Snaphook for 1/4" Hole 77#
Cable Assembly Capacity1
3/32” Cable
1/8” Cable
126#
223#
• Provides support for Pipe• Wedgy arms are designed for punched or slotted strut• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
A
CB
Qty.2ea
164
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
93
0
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Single Wedgy Arms for Strut TrapezeFig 930
How to determine the Wedgy Complete Assembly Capacity1
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Refer to page 174 for pipe weights to determine support spacing requirements
FOOTNOTES:1) Capacties shown are for the cable assembly and attachment to structure only. The trapeze is not taken into consideration.2) Capacities are reduced to account for the potential of eccentric loading on trapezes
Cable Assembly Capacity2
3/32” Cable
1/8” Cable
126#
223#
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
73#126#
146#252#146#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
165
FIG
93
1
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 2ea Cable assemblies with selected anchors• 4ea Single Wedgys
• Provides support for Conduit and Cable Tray• Wedgy arms are designed for punched or slotted strut• Quick installation and adjustment• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 9 3 1 Single Wedgy Arms for 2-Tier Strut Trapeze
FOOTNOTES:1) Ultimate capacities have been reduced to take into consideration eccentric loads on the trapeze 2) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 3) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A(6**) B C Qty
Fig 931
Fig 931
Fig 931
A B C
Attachment to Structure2
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)3 73# 640-1 Wood Eyelag - 1/4” x 3” 208# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)3 42# 640-2 Wood Eyelag - 1/4” x 4” 208# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)3 72# 640-3 Wood Eyelag - 1/4” x 5” 208# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)3 119# 641 Timberpin 77# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 84# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 165#660
Pigtail Loop - 20g Deck (No Fill) 102# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 231# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 200#661
Rebar Tie - 22g Deck (No Fill) 154# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 77# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 53# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 112# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 96# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 96# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 231# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 154# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 80#
624-2 90° Clip and #10 HWH Sharp Point (22g) 35#
628 Snaphook for 1/4" Hole 77#
Cable Assembly Capacity1
3/32” Cable
1/8” Cable
126#
223#
A
CB
Qty.2ea
Qty.4ea
166
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
93
1
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Single Wedgy Arms for 2-Tier Strut TrapezeFig 931
How to determine the Wedgy Complete Assembly Capacity1, 2
Step 1:A) Determine the capacity of the attachment to structure and multiply the capacity by 2. (Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity and multiply the capacity by 2.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Refer to page 174 for pipe weights to determine support spacing requirements
FOOTNOTES:1) Capacities noted are for each individual tier of the trapeze. The total Weight per Linear Foot of the utility for each tier must be calculated and can not exceed the capacity of the attachment to structure. 2) Capacties shown are for the cable assembly and attachment to structure only. The trapeze is not taken into consideration.3) Capacities are reduced to account for the potential of eccentric loading on trapezes.
Cable Assembly Capacity3
3/32” Cable
1/8” Cable
126#
223#
Attachment to StructureCable Assembly Capacity
X 2 =X 2 =
X 2 =X 2 =
600-1 Pin and Clip3/32” Cable
73#126#
146#252#146#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
167
FIG
95
7
© 2015-2017 CEAS, All Rights Reserved • 14848 Northam St., La Mirada, CA 90638 • Tel: 877-GOO-CEAS • Fax: 714-522-3648
Assembly contains:• 4ea Cable assemblies with selected anchors• 4ea Single Wedgys
• Provides 4 support cables for chilled beams• Fasteners are selected and pre‐staked for Concrete, Steel or Wood attachments• Engineered as a COMPLETE ASSEMBLY!• Assembly maximum capacities vary by substrate and embedment. Refer to the guidelines on the next page and tables below for useable loads• Manufactured to ASTM A1023 and ASTM A931
F i g . 9 5 7 Wedgy Chilled Beam Support
FOOTNOTES:1) Attachment Capacities listed above are worst case. For values into specific substrate conditions refer to tables on Pages 10-15) 2) For projects in Design Category C Ip>1.0 and D, E & F Ip=all Power Actuated Fasteners are limited to 90#. (OSHPD Projects 70#)
Contractor:
PO# Order Date:
Ship to Address:
**All Orders are Custom and Therefore Non-cancellable and Non-returnable
A(6**) B C Qty
Fig 957
Fig 957
Fig 957
A B C
Attachment to Structure1
CableDiameter
CableLengthConcrete Connections Anchor
Capacity Wood Connections AnchorCapacity
600-1 Powers Pin & Clip (1-1/8” Embed.)2 95# 640-1 Wood Eyelag - 1/4” x 3” 270# *01 1/16" Cable *01 3’
600-2 Powers Pin & Clip (7/8” Embed.)2 55# 640-2 Wood Eyelag - 1/4” x 4” 270# *02 3/32" Cable *02 6’
600-3 Ramset Pin & Clip (1-1/8” Embed.)2 94# 640-3 Wood Eyelag - 1/4” x 5” 270# *03 1/8" Cable *03 9’
600-4 Ramset Pin & Clip (3/4” Emb. NWC ONLY)2 155# 641 Timberpin 100# *04 12’
601-1 90° Clip and 1/4” (5/16”) x 2” Tapcon 110# Cast-in-Place Connections Load *05 15’
601-2 90° Clip and 3/8” x 3” Tapcon 215#660
Pigtail Loop - 20g Deck (No Fill) 133# *06 18’
602-1 90° Clip and 1/4” x 3-1/4” Wedge Anchor 314# Pigtail Loop - 20g Deck with LWC 300# *07 21’
602-2 90° Clip and 3/8” x 3” Wedge Anchor 261#661
Rebar Tie - 22g Deck (No Fill) 200# *08 24’
605 Tie Wire Wedge Anchor (1/4" Dia.) 100# Rebar Tie - 22g Deck with LWC 314# *09 27’
606 Tie Wire Spike Anchor (1/4" Dia.) 70# 665 3/8 x 2-1/2" Stud (PIP Blue Banger) 314# *10 30’
Steel Connections Load 667 3/8 x 5" Stud (SDI Blue Banger) 314# *25 Custom
620 Loop Connection 146# 668 3/8 x 2-1/2" Stud (PIP PushRod) 314#
621-1 Metal Eyelag - 1/4" x 3/4” (2” OAL) 20g 125# 669 3/8 x 5" Stud (SDI PushRod) 314#
621-2 Metal Eyelag - 1/4" x 2” (3-1/4” OAL) 20g 125# Angle Clip Only Load
622 Bar Joist Pull-down Clamp 300# 682 90° Bracket with 1/4" Anchor Hole N/A
623 Hammer-on Beam Clamp 200# 683 90° Bracket with 3/8" Anchor Hole N/A
624-1 90° Clip and #10 HWH Self Driller (20g) 104#
624-2 90° Clip and #10 HWH Sharp Point (22g) 46#
628 Snaphook for 1/4" Hole 100#
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
A
CB
Qty.4ea
168
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
FIG
95
7
CONSTRUCTION ENGINEERED ATTACHMENT SOLUTIONSIt’s What We Do!
Wedgy Chilled Beam SupportFig 957
How to determine the Wedgy Complete Assembly Capacity
Step 1:A) Determine the capacity of the attachment to structure. Listed in column A or on Pages 10-15)
B) Determine the Cable Assembly Capacity.
Step 2:The lessor of the 2 values is the Wedgy Complete Assembly Capacity.
Attachment to StructureCable Assembly Capacity
X 4 =X 4 =
X 4 =X 4 =
600-1 Pin and Clip3/32” Cable
95#158#
380#632#380#
Variable VariableCapacity Capacity
Example
Wedgy Complete Assembly Capacity Wedgy Complete Assembly Capacity
Actual
Cable Assembly Capacity
1/16” Cable
3/32” Cable
1/8” Cable
77#
158#
314#
169
Co
nst
ruct
ion
En
gin
ee
red
Att
ach
me
nt
So
luti
on
s S
ince
19
77
Support Spacing
5 feet 6 feet 7 feet 8 feet 10 feet 12 feet
Utility Weight
Per Linear Foot
10 lbs/Lf 50 lbs 60 lbs 70 lbs 80 lbs 100 lbs 120 lbs
15 lbs/Lf 75 lbs 90 lbs 105 lbs 120 lbs 150 lbs 180 lbs
20 lbs/Lf 100 lbs 120 lbs 140 lbs 160 lbs 200 lbs 240 lbs
25 lbs/Lf 125 lbs 150 lbs 175 lbs 200 lbs 250 lbs 300 lbs
30 lbs/Lf 150 lbs 180 lbs 210 lbs 240 lbs 300 lbs 360 lbs
35 lbs/Lf 175 lbs 210 lbs 245 lbs 280 lbs 350 lbs 420 lbs
40 lbs/Lf 200 lbs 240 lbs 280 lbs 320 lbs 400 lbs 480 lbs
45 lbs/Lf 225 lbs 270 lbs 315 lbs 360 lbs 450 lbs 540 lbs
50 lbs/Lf 250 lbs 300 lbs 350 lbs 400 lbs 500 lbs 600 lbs
Wedgy Device Capacities and Support Reduction Requirements1
90° 75° 60° 45°
WEDGY12No. 1 Cable 77 lbs 73 lbs 67 lbs 54 lbs
No. 2 Cable 158 lbs 152 lbs 137 lbs 112 lbs
WEDGY23No. 2 Cable 158 lbs 152lbs 137 lbs 112 lbs
No. 3 Cable 314 lbs 301 lbs 273 lbs 223 lbs
DSCU23No. 2 Cable
103 lbs 99 lbs 90 lbs 70 lbsNo. 3 Cable
DSCL23No. 2 Cable
173 lbs 166 lbs 151 lbs 117 lbsNo. 3 Cable
DSC Upper 103 lbs 99 lbs 90 lbs 73 lbs
Lower 173 lbs 166 lbs 151 lbs 122 lbs
SW23 (16g)2No. 2 Cable
112 lbs 108 lbs 97 lbs 76 lbsNo. 3 Cable
SW23 (12g)2No. 2 Cable 125 lbs 120 lbs 109 lbs 88 lbs
No. 3 Cable 231 lbs 222 lbs 201 lbs 163 lbs
SWP232No. 2 Cable 126 lbs 121 lbs 110 lbs 89 lbs
No. 3 Cable 223 lbs 214 lbs 194 lbs 158 lbs
Te c h n i c a l D a t a
WEDGY12 andWEDGY23
DSCU23 DSCL23 DSC SW23 SW2P3
These reduction factors apply when supportarms are oriented Inbound or Outbound.
Footnotes:1) All capacities shown are based on a 5:1 SWL (Safe Working Load)2) In addition to the SWL, capacities shown for the SW2 and SWP2 have been reduced for eccentric loading
Example: 20g 24” x 36” Rectangular Duct
Utility Weight/LF = 19.9 Lbs/Lf
Support Spacing = 8’ O.C.Load Per Support = (19.9 Lbs/Lf * 8’ O.C.) = 159.2 Lbs
Load Per Support Arm = (159.2Lbs / 2 Arms) = 79.6 Lbs
Wedgy Device Capacities
How to Determine Loads at Support Locations
170
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
International Building Code Requirements ‐ Seismic Design Category C, D, E and F
AllA minimum of two attachment devices are required to secure each fixture to the ceiling grid. The attachment device shall have the capacity of supporting 100 % of the lighting fixture weight acting in any direction.
Surface‐mountedlighting fixtures
Shall be attached to the ceiling system with a positive clamping device that completely surrounds the supporting members. Safety wires shall be attached between the clamping device and the adjacent ceiling hanger or to the structure above. In no case shall the fixture exceed the design carrying capacity of the supporting members.
Fixtures < 10# Provide 1ea safety wire to the fixture housing.
Fixtures 10# > 56# Provide 2ea safety wires to the fixture housing.
Fixtures > 56# Shall be independently supported from the structure above by approved hangers.
California Building Code Requirements ‐ Seismic Design Category C (Ip=1.5) and D, E and F (Ip=All)
AllA minimum of two attachment devices are required to secure each fixture to the ceiling grid. The attachment device shall have the capacity of supporting 100 % of the lighting fixture weight acting in any direction.
Surface‐mountedlighting fixtures
Shall be attached to the ceiling system with a positive clamping devices made of material with a minimum of 14g that completely surrounds the supporting members. Rotational spring catches do not comply. Safety wires shall be atached between the clamping device and the adjacent ceiling hanger or to the structure above. In no case shall the fixture exceed the design carrying capacity of the supporting members. Provide additional supports when the light fixture exceeds 8’.
Fixtures < 56# Provide 2ea safety wires to the fixture housing at diagonal corners.
Fixtures > 56#Must be independently supported from the structure by a minimum of 4ea direct supports to structure designed with a 4:1 safety factor.
All lightweight miscellaneous devices, such as strobe lights, speakers, etc.
10# > 20# Provide 1ea safety wire to the fixture housing.
10# > 20# Provide 2ea safety wires to the fixture housing at diagonal corners.
Support Requirements For Ceiling Mounted Light Fixtures
Electrical Metallic Tubing (EMT) ‐ Thinwall Conduit
Trade SizeInch
Weight ofConduit Lbs/Lf
Weight ofConductor Lbs/Lf
Conduit +
Conduit +Conductor Weight
Lbs/Lf
1/2 0.3 0.24 0.54
3/4 0.46 0.46 0.92
1 0.67 0.71 1.38
1-1/4 1.01 1.32 2.33
1-1/2 1.16 2.20 3.36
2 1.48 3.30 4.78
2-1/2 2.16 4.12 6.28
3 2.63 6.97 9.60
3-1/2 3.49 8.45 11.94
4 3.93 9.14 13.07
Galvanized Rigid Conduit (GRC)
Trade SizeInch
Weight ofConduit Lbs/Lf
Weight ofConductor Lbs/Lf
Conduit +
Conduit +Conductor Weight
Lbs/Lf
1/2 0.82 0.24 1.06
3/4 1.09 0.46 1.55
1 1.61 0.71 2.32
1-1/4 2.18 1.32 3.50
1-1/2 2.63 2.20 4.83
2 3.50 3.30 6.80
2-1/2 5.59 4.12 9.71
3 7.27 6.97 14.24
3-1/2 8.80 8.45 17.25
4 10.30 9.14 19.44
5 14.00 16.95 30.95
6 18.40 39.30 57.70
Basic Element Weights For Electrical Conduit
171
Co
nst
ruct
ion
En
gin
ee
red
Att
ach
me
nt
So
luti
on
s S
ince
19
77
Wedgy Overall Cable Lengths Looped Connection 1,2,3
Duct Dia.
Duct Circum.
Wedgy Dist. "A"
Drop Length (ft.)
6’ 8’ 10’ 12’ 14’ 16’ 18’ 20’
12“ 38” 3” 12’ 12’ 15’ 18’ 18’ 21’ 24’ 24’
14” 44” 3.5” 12’ 15’ 15’ 18’ 21’ 21’ 24’ 27’
16” 50” 4” 12’ 15’ 15’ 18’ 21’ 21’ 24’ 27’
18” 57” 4.5” 12’ 15’ 18’ 18’ 21’ 24’ 24’ 27’
20” 63” 5” 15’ 15’ 18’ 21’ 21’ 24’ 27’ 27’
22” 69” 5.5” 15’ 15’ 18’ 21’ 21’ 24’ 27’ 27’
24” 75” 6” 15’ 18’ 18’ 21’ 24’ 24’ 27’ 30’
26” 82” 6.5” 15’ 18’ 18’ 21’ 24’ 24’ 27’ 30’
28” 88” 7” 15’ 18’ 21’ 21’ 24’ 27’ 27’ 30’
30” 94” 7.5” 15’ 18’ 21’ 21’ 24’ 27’ 27’ 30’
32” 101” 8” 18’ 18’ 21’ 24’ 24’ 27’ 30’ 30’
34” 107” 8.5” 18’ 21’ 21’ 24’ 27’ 27’ 30’ 33’
36” 113” 9” 18’ 21’ 21’ 24’ 27’ 27’ 30’ 33’
Wedgy Overall Cable Lengths “U” Supported 1,2
Duct Dia.
Duct Circum.
Drop Length (ft.)
6' 8' 10' 12' 14' 16' 18' 20'
36” 113” 21' 27' 30’ 33’ 39’ 42’ 45’ 51’
38” 119” 24’ 27’ 30’ 36’ 39’ 42’ 48’ 51’
40” 126” 24’ 27’ 30’ 36’ 39’ 42’ 48’ 51’
44” 138” 24’ 27’ 33’ 36’ 39’ 45’ 48’ 51’
46” 145” 24’ 27’ 33’ 36’ 39’ 45’ 48’ 51’
48” 151” 24’ 30’ 33’ 36’ 42’ 45’ 48’ 54’
50” 157” 24’ 30’ 33’ 36’ 42’ 45’ 48’ 54’
52” 163” 27’ 30’ 33’ 39’ 42’ 45’ 51’ 54’
56” 176” 27’ 30’ 33’ 39’ 42’ 45’ 51’ 54’
60” 188” 27’ 30’ 36’ 39’ 42’ 48’ 51’ 57’
Footnotes:1) Wedgy devices must maintain a distance of 1/4 the diameter of the duct away from the top of the duct.2) Wedgy cables are readily available in 3’ increments.3) Cable diameters should be selected based on the weigh/linear foot of the ductwork and hanger spacing.
Footnotes:1) Wedgy cables are readily available in 3’ increments.2) Cable diameters should be selected based on the weigh/linear foot of the ductwork and hanger spacing.
DROPLENGTH DIMENSION “A”
1/4” OF DUCT DIAMETER
ROUND DUCT36” & SMALLER
DROPLENGTH
ROUND DUCT36” & LARGER
Te c h n i c a l D a t a
How To Determine Wedgy Cable Lengths
172
International Building Code Requirements ‐ Seismic Design Category C
Registers < 20#Shall be postively attached to the ceiling main runners or cross runners that have the same carrying capacity as the main runners.
Registers 20# > 56#Provide 2ea safety wires and shall be positively attached to the ceiling main runners or cross runners that have the same carrying capacity as the main runners.
Registers > 56# Shall be independently supported from the structure above by approved hangers.
International Building Code Requirements ‐ Seismic Design Category D, E & F (Ip=All)
Registers < 20# Shall be positively attached to the ceiling runners.
Registers 20# > 56# Provide 2ea safety wires to the fixture housing at diagonal corners.
Registers > 56# Shall be independently supported from the structure above by approved hangers.
California Building Code Requirements ‐ Seismic Design Category C (Ip=1.5) and D, E & F (Ip=All)
AllA minimum of two screws are required to secure each fixture to the ceiling grid. The attachment device shall have the capacity of supporting 100 % of the lighting fixture weight acting in any direction.
Registers < 56# Provide 2ea safety wires to the fixture housing at diagonal corners.
Registers > 56#Must be independently supported from the structure by a minimum of 4ea direct supports to structure designed with a 4:1 safety factor.
Support Requirements For Ceiling Mounted Air Terminals
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m 173
Co
nst
ruct
ion
En
gin
ee
red
Att
ach
me
nt
So
luti
on
s S
ince
19
77
Rectangular Duct Weight Table24g 22g 20g 18g 16g
0.0276 in. 0.0336 in. 0.0396 in. 0.0516 in. 0.0635 in.1.156 lbs/ft2 1.406 lbs/ft2 1.656 lbs/ft2 2.156 lbs/ft2 2.656 lbs/ft2
* 10% added for fittings up to 46" min dim ** 20% added for fittings ≥ 48" min dim
*** Insulation weight = 1.50 pcf **** Sheet Metal Weight per SMACNA Appendix A
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 40 44 486 3.4 3.9 5.2 5.8 7.6 8.3 9.0 9.7 10.4 11.0 11.7 12.48 3.9 5.2 6.0 7.6 8.3 9.0 9.7 10.4 11.0 11.7 12.4 13.1 13.8 14.5 15.2 16.610 6.9 7.6 8.3 9.0 9.7 10.4 11.0 11.7 12.4 13.1 13.8 14.5 15.2 15.9 17.3 18.6 27.412 8.3 9.0 9.7 10.4 11.0 11.7 12.4 13.1 13.8 14.5 15.2 15.9 16.6 18.0 19.3 28.414 9.7 10.4 11.0 11.7 12.4 13.1 13.8 14.5 15.2 15.9 16.6 17.3 18.6 20.0 29.316 11.0 11.7 12.4 13.1 13.8 14.5 15.2 15.9 16.6 17.3 18.0 19.3 20.7 30.318 12.4 13.1 13.8 14.5 15.2 15.9 16.6 17.3 18.0 18.6 20.0 21.4 31.220 13.8 14.5 15.2 15.9 16.6 17.3 18.0 18.6 19.3 20.7 22.1 32.222 15.2 15.9 16.6 17.3 18.0 18.6 19.3 20.0 21.4 22.8 33.124 16.6 17.3 18.0 18.6 19.3 20.0 20.7 22.1 23.5 34.026 18.0 18.6 19.3 20.0 20.7 21.4 22.8 24.2 35.028 19.3 20.0 20.7 21.4 22.1 23.5 24.9 35.930 20.7 21.4 22.1 22.8 24.2 25.5 36.936 23.5 24.2 24.9 26.2 27.6 39.740 24.9 25.5 26.2 27.6 29.0 41.644 30.4 43.548 45.4
52 56 60 64 68 72 76 80 84 88 92 96 100 104 108 112 116 12010 29.312 30.3 32.2 34.014 31.2 33.1 35.0 36.9 38.8 40.716 32.2 34.0 35.9 45.8 48.1 50.4 52.7 55.018 33.1 35.0 36.9 47.0 49.3 51.6 53.8 56.1 58.4 60.7 63.020 34.0 35.9 37.8 48.1 50.4 52.7 55.0 57.3 59.6 61.9 64.2 66.5 68.722 35.0 36.9 38.8 40.7 51.6 53.8 56.1 58.4 60.7 63.0 65.3 67.6 69.9 72.2 74.5 76.824 35.9 37.8 39.7 50.4 52.7 55.0 57.3 59.6 61.9 64.2 66.5 68.7 71.0 73.3 75.6 77.9 80.2 82.526 36.9 38.8 40.7 51.6 53.8 56.1 58.4 60.7 63.0 65.3 67.6 69.9 72.2 74.5 76.8 79.1 81.3 83.628 37.8 39.7 41.6 52.7 55.0 57.3 59.6 61.9 64.2 66.5 68.7 71.0 73.3 75.6 77.9 80.2 82.5 84.830 38.8 40.7 42.6 53.8 56.1 58.4 60.7 63.0 65.3 67.6 69.9 72.2 74.5 76.8 79.1 81.3 83.6 85.936 41.6 43.5 45.4 57.3 59.6 61.9 64.2 66.5 68.7 71.0 73.3 75.6 77.9 80.2 82.5 84.8 87.1 89.440 43.5 45.4 47.3 59.6 61.9 64.2 66.5 68.7 71.0 73.3 75.6 77.9 80.2 82.5 84.8 87.1 89.4 91.744 45.4 47.3 49.2 61.9 64.2 66.5 68.7 71.0 73.3 75.6 77.9 80.2 82.5 84.8 87.1 89.4 91.7 94.048 47.3 49.2 61.9 64.2 66.5 68.7 71.0 73.3 75.6 77.9 80.2 82.5 84.8 87.1 89.4 91.7 94.0 96.254 63.0 65.3 67.6 69.9 72.2 74.5 76.8 79.1 81.3 83.6 85.9 88.2 90.5 92.8 95.1 97.4 99.760 68.7 71.0 73.3 75.6 77.9 80.2 82.5 84.8 87.1 89.4 91.7 94.0 96.2 98.5 100.8 103.166 76.8 79.1 81.3 83.6 85.9 88.2 90.5 92.8 95.1 97.4 99.7 102.0 104.3 106.672 82.5 84.8 87.1 89.4 91.7 94.0 96.2 98.5 100.8 103.1 105.4 107.7 110.0
Te c h n i c a l D a t a
174
Round Duct Weight Table
Diameter (In.)
22 GA. 20 GA. 18 GA. 16 GA.
Duct Weight Per Linear Ft
(Lbs/Ft.)
Insulation Thickness
(In.)
Insulated Duct Wt. Per Ft. (Lbs./Ft.)
Duct Weight Per Linear Ft
(Lbs/Ft.)
Insulation Thickness
(In.)
Insulated Duct Wt. Per Ft. (Lbs./Ft.)
Duct Weight Per Linear Ft
(Lbs/Ft.)
Insulation Thickness
(In.)
Insulated Duct Wt. Per Ft. (Lbs./Ft.)
Duct Weight Per Linear Ft
(Lbs/Ft.)
Insulation Thickness
(In.)
Insulated Duct Wt. Per Ft. (Lbs./Ft.)
12 4.9 2 5.614 5.7 2 6.616 6.5 2 7.518 7.3 2 8.5 8.6 2 9.820 8.1 2 9.4 9.5 2 10.8 12.4 2 13.722 8.9 2 10.3 10.5 2 11.9 13.7 2 15.124 9.7 2 11.3 11.4 2 13.0 14.9 2 16.526 10.5 2 12.2 12.4 Z 14.1 16.1 2 17.828 11.3 2 13.2 13.4 2 15.2 17.4 2 19.230 18.1 2 14.1 14.3 2 16.3 18.6 2 20.632 13.0 2 15.1 15.3 2 17.4 19.9 2 22.034 13.8 2 16.0 16.2 Z 18.4 21.1 2 23.336 14.6 2 16.9 17.2 2 19.5 22.4 2 24.7 27.5 2 29.938 15.4 2 17.9 18.1 2 20.6 23.6 2 26.1 29.1 2 31.640 16.2 2 18.8 19.1 2 21.7 24.8 2 27.5 30.6 2 33.244 17.8 2 20.7 21.0 2 23.9 27.3 2 30.2 33.7 2 36.548 21.2 2 24.3 25.0 2 28.1 32.5 2 35.7 36.7 2 39.950 22.1 2 25.4 26.0 2 29.3 33.9 2 37.1 38.2 2 41.554 23. 9 2 27.4 28.1 2 31.6 36.6 2 40.1 41.3 2 44.856 24. 7 2 28.8 29.1 2 32.8 37.9 2 41.6 42.8 2 46.560 26. 6 2 30.4 31.2 2 35.1 40.6 2 44.6 45.9 2 49.866 29. 2 2 33.5 34.3 2 38.7 44.7 2 49.0 50. 5 2 54.872 37.5 2 42.2 48.8 2 53.5 55.1 2 59.878 40.6 2 45.7 52.8 2 57.9 59.7 2 64.884 43.7 2 49.2 56.9 2 62.4 64.2 2 69.790 48.8 2 52.7 61.0 2 66.9 68.8 2 74.796 49.9 2 56.2 65.0 2 71.3 73.4 2 79.7
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m 175
Co
nst
ruct
ion
En
gin
ee
red
Att
ach
me
nt
So
luti
on
s S
ince
19
77
Steel Pipe Data: Schedule 40
Pipe Dia. Inch
Pipe Weight Empty Lbs/Lf
Weight of Water Lbs/Lf
Pipe Weight Full
Lbs/Lf
Insulation Thickness*
Inch
Insulation Weight Lbs/Lf
Pipe Weight Full &
Insulated Lbs/Lf
1/2. 0.85 0.13 0.98 1” 0.46 1.45
3/4” 1.13 0.23 1.36 1” 0.43 1.79
1” 1.70 0.37 2.07 1” 0.6 2.67
1-1/2” 2.70 0.88 3.58 1” 0.66 4.24
2” 3.60 1.45 5.05 1” 0.84 5.89
2 1/2 5.80 2.07 7.9 1" 0.96 8.8
3 7.60 3.20 10.8 1" 1.06 11.9
4 10.80 5.51 16.3 2" 3.18 19.5
Type K Copper Tubing
Pipe Dia. Inch
Pipe Weight Empty Lbs/Lf
Weight of Water Lbs/Lf
Pipe Weight Full
Lbs/Lf
Insulation Thickness*
Inch
Insulation Weight Lbs/Lf
Pipe Weight Full &
Insulated Lbs/Lf
1/2. 0.34 0.09 0.43 1” 0.46 0.89
3/4” 0.64 0.19 0.83 1” 0.43 1.26
1” 0.84 0.34 1.18 1” 0.6 1.78
1-1/2” 1.36 0.74 2.1 1” 0.66 2.76
2” 2.06 1.31 3.37 1” 0.84 4.21
2-1/2” 2.92 2 4.9 1" 0.96 5.9
3 4.01 2.96 7.0 1" 1.06 8.0
4-1/2” 5.12 3.9 9.0 1" 1.66 10.7
4 6.51 5.06 11.6 2" 3.18 14.8
Steel Pipe Data: Schedule 80
Pipe Dia. Inch
Pipe Weight Empty Lbs/Lf
Weight of Water Lbs/Lf
Pipe Weight Full
Lbs/Lf
Insulation Thickness*
Inch
Insulation Weight Lbs/Lf
Pipe Weight Full &
Insulated Lbs/Lf
1/2. 1.09 0.10 1.19 1” 0.46 1.65
3/4” 1.47 0.19 1.66 1” 0.43 2.09
1” 2.17 0.31 2.48 1” 0.6 3.08
1-1/2” 3.63 0.77 4.40 1” 0.66 5.06
2” 5.02 1.28 6.30 1” 0.84 7.14
2 1/2 7.66 1.83 9.5 1" 0.96 10.5
3 10.25 2.86 13.1 1" 1.06 14.2
4 14.98 4.98 20.0 2" 3.18 23.1
Type L Copper Tubing
Pipe Dia. Inch
Pipe Weight Empty Lbs/Lf
Weight of Water Lbs/Lf
Pipe Weight Full
Lbs/Lf
Insulation Thickness*
Inch
Insulation Weight Lbs/Lf
Pipe Weight Full &
Insulated Lbs/Lf
1/2. 1.09 0.10 1.19 1” 0.46 1.65
3/4” 1.47 0.19 1.66 1” 0.43 2.09
1” 2.17 0.31 2.48 1” 0.6 3.08
1-1/2” 3.63 0.77 4.40 1” 0.66 5.06
2” 5.02 1.28 6.30 1” 0.84 7.14
2-1/2” 2.48 2.06 4.5 1" 0.96 5.5
3 3.33 2.95 6.3 1" 1.06 7.3
4-1/2” 4.29 3.99 8.3 1" 1.66 9.9
4 5.38 5.19 10.6 2" 3.18 13.8
No-Hub Cast Iron Pipe
Pipe Dia. Inch Pipe Weight Empty Lbs/Lf
Weight of Water Lbs/Lf
Pipe Weight Full Lbs/Lf
2 3.60 1.36 5.0
3 5.20 3.06 8.3
4 7.40 5.44 12.8
5 9.40 8.50 17.9
6 11.00 12.23 23.2
8 18.00 21.75 39.7
10 25.80 33.98 59.8
12 35.50 48.93 84.4
15 51.50 76.46 128.0
* Fiber Glass Pipe Insulation With ASJ
* Fiber Glass Pipe Insulation With ASJ
* Fiber Glass Pipe Insulation With ASJ
* Fiber Glass Pipe Insulation With ASJ
Pipe Weight Tables
Te c h n i c a l D a t a
176
C E A S We d g y M a n u f a c t u r e r R e c o m m e n d a t i o n s
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
WARNINGCEAS attachments (a division of Tomarco Contractor Specialties) products shall be installed and used only as indicated in the product application details and training materials provided by CEAS Attachments. Application details are available by contacting CEAS Attachments at [email protected] or your local CEAS Attachments sales representative. Improper installation, misuse, misapplication or other failure to completely follow the application details provided by CEAS Attachments may cause product malfunction, property damage, serious bodily injury, and death.
WARRANTY AND REMEDYALL WARRANTIES OF THE PRODUCTS DESCRIBED HEREIN, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSES ARE SPECIFICALLY EXCLUDED EXCEPT FOR THE FOLLOWING: CEAS ATTACHMENTS will repair or replace at its sole option any product which within twelve months after sale by CEAS ATTACHMENTS or Its Distributors, is found by CEAS ATTACHMENTS to be defective in material or workmanship, normal wear and tear excluded. THIS IS THE SOLE WARRANTY OF CEAS ATTACHMENTS AND THE SOLE REMEDY AVAILABLE TO DISTRIBUTOR OR BUYER.
LIMITATION OF LIABILITYCEAS ATTACHMENTS SHALL NOT BE LIABLE FOR ANY: INJURY, LOSS AND/OR DAMAGE, DIRECT, INDIRECT, INCIDENTAL AND/OR CONSEQUENTIAL, ARISING OUT OF THE USE OF, AND/OR THE INABILITY TO USE, THE PRODUCTS DESCRIBED HEREIN.
Follow Assembly Capacity Guidelines ‐ Wedgy cable assembly capacities have been tested and engineered to perform to the published loads. Never overload Wedgy Cable Assemblies.
Only the Cable Supplied with the Wedgy Assembly May be Used ‐ Plastic coated cables are not permitted for use with Wedgy Devices.
Wedgys can Only be Used in Dry Indoor Environments ‐ Wedgy cable assemblies can not be used in wet, chlorinated, or other toxic environments.
Do Not Walk or Stand on Utilities ‐ The Wedgy cable assembly capacities do not account for the loads attributed to installers walking or standing on the component after installation.
Cables Must be Free of Oil or Fire Proofing Prior to Installation ‐ Wedgy cables must be free of any outside contaminants prior to the installation of the Wedgy device. Wedgys can be supplied in bags to protect the cables during the application of fireproofing.
Do Not Paint Cables Prior to Installation ‐ Do not paint the Wedgy Device. The Wedgy device must be in the final position and protected prior to painting. Wedgy devices can not be adjusted once paint has been applied to the cables.
Reductions Must be Taken When Cables are Not Installed at 90° ‐ In order to take into consideration the tension and shear effects on cables that are not installed vertical, reductions must be made. Refer to the load reduction tables on page 64.
When Cable is Looped Around Round Duct or Similar Applications, the Resulting Angle Shall Not Exceed 60°
Y‐Accessories and Y‐Assemblies May Not be Installed at an Angle Greater than 60°
Never Join 2 Cables into 1 Wedgy Device ‐ This dramatically reduces the capacity of the supports and voids all engineering and warranties.
Do Not Use for Lifting ‐ Wedgy assemblies are not designed to be used as part of a system for lifting. The supports are designed as a static support only for overhead applications.
>60°
>60°
177
Co
nst
ruct
ion
En
gin
ee
red
Att
ach
me
nt
So
luti
on
s S
ince
19
77
O r d e r O n l i n e w w w . C E A S a t t a c h m e n t s . c o m
Easily connects to the Wedgy Snap Hook assemblyWorks on 1/16” - 1/4” flanges160 lbs capacity
Vertical Flange Clip
Easily connects to the Wedgy Snap Hook assemblyWorks on 1/16” - 1/4” flanges160 lbs capacity
Hammer-on Beam Clamp
Strip Light Brackets
Easily cuts through No. 1 through No. 3 CableHardened Steel Teeth
Cable Cutters
Works with all available cable diametersPrevents the cable from touching the ductwork
Corner Cradle Flex Saddle
PartNumber
FlangeThickness
(in)
StandardPackagingQuantity
Capacity(lbs)
2H4 3/32 to 9/64 100 160
4H24 1/8 to 1/4 100 200
4H58 5/16 to 1/2 100 200
4H912 9/16 to 3/4 100 200
Part Number
FS12 5” - 6” Flex
FS18 7” - 10” Flex
FS24 12” - 14” Flex
FS31 16” - 18” Flex
Part # Width Height Capacity (lbs)
FMS 3-1/4” 4-3/4” 30
FMF 3-1/2” 4” 30
Part #Flange
Thickness (in)Standard
Packaging Qty.Capacity
(lbs)
VF14 1/16” to 1/4” 100 160
Part Number: CC
Part Number: WEDGYCT123
Part Number: FASTBALL
Shown with Fig 628
Shown with Fig 628
Fastball
Works with all available cable diametersPrevents the cable from touching the ductwork
Quickly locks into fixture mounting holes (Available for side mount or front mounted fixtures)
Quickly secures perpendicular cables with NO TOOLS!
Works with No. 1, 2 and 3 cables.
FMS Side Fixture Mount
FMF Front Fixture Mount
178
1Drill Using Roto
Hammer Pole Tool
2Set Wedge Anchor with Driver Head
3Tighten with
Impact Pole Tool
Impact PoleCustom order exclusive
A c c e s s o r i e s a n d I n s t a l l a t i o n To o l s
Desig
ned
by p
rofessio
nals fo
r pro
fession
als!
CEAS carries a complete line of attachment pole tools for every type of application.
Visit www.CEASattachments.com
Use with Wedge Anchor Use with Spike Anchor
CEAS exclusive roto-hammer installaion system.
Universal cradle section fits several rotohammers and can be modified to to fitother shapes - Contact CEAS with your model number to confirm suitability or for a cus-tomized tool.
Special Order Custom Lengths.
Visit CEAS website for sectional pole options.
Designed to fit: Makita HR2400, HR2410, HR2470F, DeWalt D25123K, D25012K.
SDS Wedge Anchor/Spike Install Tool
Roto Hammer Pole
DESCRIPTION PART #
SDS Tie Wire Tool MAKRHTW
DESCRIPTION PART #
Sectional - Cradle Only POLMAK
Fixed Length
4’ Fixed Length Pole POLMAKRH4
6’ Fixed Length Pole POLMAKRH6
8’ Fixed Length Pole POLMAKRH8
10’ Fixed Length Pole POLMAKRH10
12’ Fixed Length Pole POLMAKRH12
Custom Length Special Order
Use with Wedge Anchor and Spike anchor
SDS Wedge Anchor Install Tool
DESCRIPTION PART #
SDS Wedge Tool 7/16” WAI7/16
SDS Wedge Tool 1/2” WAI1/2
DS Wedge Tool 9/16” WAI9/16
DS Wedge Tool 5/8” WAI5/8
DS Wedge Tool 11/16” WAI11/16
DS Wedge Tool 3/4” WAI3/4
Shown withpre-assembledSpike Anchor
Shown withpre-assembledWedge Anchor
Socket Drive and Shank Drive Options
179
Overhead Attachment Tool for Concrete, Wood and Steel Applications
The newly remastered Stiffy .27 caliber powder actuated tool makes overhead attachment applications easier than ever.
Suppressed Noise is Perfect forHospitals, Tenent Improvement,Occupied or Enclosed Areas WithoutDistruption or Hearing Discomfort
Ball Lock Designfor User Safety
Stiffy Performance AdvantagesPowerful - Popular .27 caliber 10 shot strip loads provide all the drive-ability needed for professional applications.
Minimal field maintenance and no tools are required to remove nosepiece and piston to clean the barrel.
Heavy duty manual indexing lever provides positive feed engagment for reliability and eliminates load skipping.
Compact & lightweight design (under 5 lbs) is far easier to manuever and easily fits in tight spaces.
Durable ringless piston with 1-1/2” overdrive prevents breakage in thick fireproof applications.
Actuated by an upward pole impact motion against work surface.
Fixed length or telescoping pole tools easily remove to change lengthsor for lockable tool storage to prevent theft.
Sho
wn
wit
h t
he
Stif
fy F
ixed
Po
le T
oo
l an
d a
Sti
ffy
Stra
igh
t R
od
Su
pp
ort
Designed by Professionalsfor Professionals
Overhead Attachment Solutions
StiffyFig 100
WedgyFig 600
StiffyFig 105
WedgyFig 641
NOISE
S u p e r i o r D R I V E - A B I L I T Y w i t h o u t t h e N O I S E !
© 2017 CEAS - All Rights Reserved C E A S a t t a c h m e n t s . c o m
Attac
hmen
t Sol
utio
ns S
ince
197
7
180
Overhead Attachment Tool for Concrete, Wood and Steel Applications
Suppressed Noise is Perfect forHospitals, Tenent Improvement,Occupied or Enclosed Areas WithoutDistruption or Hearing Discomfort
Stiffy Performance Advantages
S u p e r i o r D R I V E - A B I L I T Y w i t h o u t t h e N O I S E !
Stiffy Side Car• Patent pending Stiffy Side Car saves time and labor
• Keeps plenty of pre-assembled cable supports right on the pole so you can work quickly and efficiently
• Works with both telescoping and fixed length Stiffy overhead pole tools
Stiffy Telescoping Pole Tool
Stiffy Fixed Length Pole Tool
Stiffy Timberpin Nosepiece
• Easy installation from the ground for high reach applications (safer than ladders)
• Aircraft quality aluminum
• Ergonomic foam comfort grip
• Choose 2 or 3 stage (3’-6’, 6’-12’, 6’-18’, 8’-24’)
• Provides easy installation from the ground (safer than ladders)
• Reinforced fiberglass with ergonomic rubber comfort grip
• Choose standard fixed lengths (4’, 6’, 8’, 10’, 12’)
• Fastest way to secure to wood structures
• 2-1/2” extended nosepiece
Sho
wn
wit
h S
tiff
y Te
lesc
op
ing
Po
le T
oo
l plu
s Si
de
Car
an
d W
edg
y C
able
Su
pp
ort DESCRIPTION ORDER #Stiffy Tool STTOOL
Stiffy Timber Pin Nosepiece ST212
Stiffy Side Car STSC
Telescoping Stiffy Pole
2 Stage 3’ - 6’ POLTV36
2 Stage 6’ - 12’ POLTV612
3 Stage 6’ - 18’ POLTV618
3 Stage 8’ - 24’ POLTV824
DESCRIPTION ORDER #Fixed Length Stiffy Pole
4’ Fixed Length Pole POLV4
6’ Fixed Length Pole POLV6
8’ Fixed Length Pole POLV8
10’ Fixed Length Pole POLV10
12’ Fixed Length Pole POLV12
Custom Length Special Order
SAVES
LABO
R
SAVES
TIM
E
181
ww
w.CEA
Satta
chm
ents.
com
(877
) GOO-C
EAS
(877
) 466
-232
7
A Divi
sion o
f Tom
arco
Contra
ctor S
pecial
ties
1484
8 North
am St
., La M
irada,
CA 9063
8
©2017
CEA
S - A
ll Rig
hts Res
erve
d
DISTRIBUTED BY: