*23056916_1216*Antriebstechnik \ Antriebsautomatisierung \ Systemintegration \ Services
Data sheet
MOVITRAC® 07B, MOVITRAC® 07AInformation regarding UL
Ausgabe 12/2016 23056916/DE
SEW-EURODRIVE—Driving the world
Inhaltsverzeichnis
Data sheet – Information regarding UL 3
Inhaltsverzeichnis1 MOVITRAC® 07B ...................................................................................................................... 4
1.1 Information Regarding UL............................................................................................... 41.1.1 Field Wiring Power Terminals ........................................................................ 41.1.2 Short Circuit Current Rating ........................................................................... 41.1.3 Branch Circuit Protection ............................................................................... 51.1.4 Motor Overload Protection ............................................................................. 81.1.5 Ambient Temperature .................................................................................... 81.1.6 Environmental Conditions .............................................................................. 8
1.2 Wiring diagram................................................................................................................ 9
2 MOVITRAC® 07A .................................................................................................................... 112.1 Information Regarding UL............................................................................................. 11
2.1.1 Field Wiring Power Terminals ...................................................................... 112.1.2 Short Circuit Current Rating ......................................................................... 112.1.3 Branch Circuit Protection ............................................................................. 122.1.4 Motor Overload Protection ........................................................................... 132.1.5 Ambient Temperature .................................................................................. 132.1.6 Environmental Conditions ............................................................................ 13
2.2 Wiring diagram 230 V 0.37 – 2.2 kW / 400 V 0.55 – 4.0 kW......................................... 142.3 Wiring diagram 230 V 3.7 – 30 kW / 400 V 5.5 – 45 kW............................................... 15
2305
6916
/DE
– 12
/201
6
1 MOVITRAC® 07BInformation Regarding UL
Data sheet – Information regarding UL4
1 MOVITRAC® 07B1.1 Information Regarding UL1.1.1 Field Wiring Power Terminals
• Use 75 °C copper wire only – models with suffix 0075, 0110, 0370, 0450, 0550,0750.Use 60/75 °C copper wire only – models with suffix 0003, 0004, 0005, 0008, 0011,0015, 0022, 0030, 0037, 0040, 0055, 0150, 0220, 0300.
• Tighten terminals to in-lbs (Nm) as follows:Series Frame Size in-lbs NmMOVITRAC® 0XS, 0S, 0L 4 0.5
1, 2S 5 0.62 13 1.53 31 3.54, 5 120 14
1.1.2 Short Circuit Current RatingSuitable for use on a circuit capable of delivering not more than• 200,000 rms symmetrical amperes when protected by fuses and circuit breakers
as described in the tables below.• 65,000 rms symmetrical amperes when protected by ABB and Rockwell Type E
Combination Motor controllers as described in the tables below.• MOVITRAC® models with suffix 0003 to 0750 (400 V units only).
Max. voltage is limited to 500 V.• MOVITRAC® models with suffix 0003 to 0300 (230 V units only).
Max. voltage is limited to 240 V.
2305
6916
/DE
– 12
/201
6
1MOVITRAC® 07BInformation Regarding UL
Data sheet – Information regarding UL 5
1.1.3 Branch Circuit ProtectionIntegral solid state short circuit protection does not provide branch circuit protection.Branch circuit protection must be provided in accordance with the National ElectricalCode and any additional local codes.
Single Phase 200 V – 240 V Voltage RangeSCCR: 200 kA/ 500 Vwhen protected by:
SCCR: 200 kA/ 500 Vwhen protected by:
SCCR: 65 kA/ 480 V 1)
when protected by:SCCR: 65 kA/ 460 Vwhen protected by:
Model Non Semiconductor Fu-ses (currents are maxi-mum values)
Inverse-Time CircuitBreaker
Type E Combination Motor Controller
MOVITRAC MC07B 0003(Size 0XS)
15 A / 250 V 25 A max / 240 V Min ABB, Model MS132-6.3Rated 480 V, 3 HP
Rockwell Automation Mo-del 140M-C2E-B63, Rated460 V, 5 HP
MOVITRAC MC07B 0004(Size 0XS)
15 A / 250 V 25 A max / 240 V Min ABB, Model MS132-10Rated 480 V, 5 HP
Rockwell Automation Mo-del 140M-C2E-C10, Ra-ted 460 V, 7.5 HP
MOVITRAC MC07B 0005(Size 0S)
15 A / 250 V 25 A max / 240 V Min ABB, Model MS132-12Rated 480 V, 7.5 HP
Rockwell Automation Mo-del 140M-D8E-C16, Ra-ted 460 V, 10 HP
MOVITRAC MC07B 0008(Size 0S)
15 A / 250 V 25 A max / 240 V Min ABB, Model MS132-12Rated 480 V, 7.5 HP
Rockwell Automation Mo-del 140M-D8E-C16, Ra-ted 460 V, 10 HP
MOVITRAC MC07B 0011(Size 0L)
30 A / 250 V 30 A max / 240 V Min ABB, Model MS132-20Rated 480 V, 10 HP
Rockwell Automation Mo-del 140M- D8E-C20, Ra-ted 460 V, 15 HP
MOVITRAC MC07B 0015(Size 0L)
30 A / 250 V 30 A max / 240 V Min ABB, Model MS132-25Rated 480 V, 15 HP
Rockwell Automation Mo-del 140M-F8E-C25, Rated460 V, 20 HP
MOVITRAC MC07B 0022(Size 0L)
30 A / 250 V 30 A max / 240 V Min ABB, Model MS132-25Rated 480 V, 15 HP
Rockwell Automation Mo-del 140M-F8E-C25, Rated460 V, 20 HP
1) Drives employing Type E Combination Motor Controller model MS132-12, -16, -20, -25, -32 must be installed with Current LimiterSeries S803W-SCLxxx-SR manufactured by ABB, otherwise SCCR rated 30kA/ 480 V0 Vrms
2305
6916
/DE
– 12
/201
6
1 MOVITRAC® 07BInformation Regarding UL
Data sheet – Information regarding UL6
Three Phase 200 V – 240 V Voltage RangeSCCR: 200 kA/ 240 Vwhen protected by:
SCCR: 200 kA/ 240 Vwhen protected by:
SCCR: 65 kA/ 240 Vwhen protected by:1)
SCCR: 65 kA/ 240 Vwhen protected by:
Model Non Semiconductor Fu-ses (currents are maxi-mum values)
Inverse-Time CircuitBreaker
Type E Combination Motor Controller
MOVITRAC MC07B 0003(Size 0XS)
15 A / 250 V 25 A max / 240 V Min ABB, Model MS132-2.5Rated 480 V, 1 HP
Rockwell Automation Mo-del 140M-C2E-B25, Rated460 V, 1.5 HP
MOVITRAC MC07B 0004(Size 0XS)
15 A / 250 V 25 A max / 240 V Min ABB, Model MS132-2.5Rated 480 V, 1 HP
Rockwell Automation Mo-del 140M-C2E-B25, Rated460 V, 1.5 HP
MOVITRAC MC07B 0005(Size 0S)
15 A / 250 V 25 A max / 240 V Min ABB, Model MS132-4.0Rated 480 V, 2 HP
Rockwell Automation Mo-del 140M-C2E-B40, Rated460 V, 3 HP
MOVITRAC MC07B 0008(Size 0S)
15 A / 250 V 25 A max / 240 V Min ABB, Model MS132-6.3Rated 480 V, 3 HP
Rockwell Automation Mo-del 140M-C2E-B63, Rated460 V, 5 HP
MOVITRAC MC07B 0011(Size 0L)
30 A / 250 V 25 A max / 240 V Min ABB, Model MS132-6.3Rated 480 V, 3 HP
Rockwell Automation Mo-del 140M-C2E-B63, Rated460 V, 5 HP
MOVITRAC MC07B 0015(Size 0L)
30 A / 250 V 25 A max / 240 V Min ABB, Model MS132-10Rated 480 V, 5 HP
Rockwell Automation Mo-del 140M-C2E-C10, Ra-ted 460 V, 7.5 HP
MOVITRAC MC07B 0022(Size 0L)
30 A / 250 V 25 A max / 240 V Min ABB, Model MS132-10Rated 480 V, 5 HP
Rockwell Automation Mo-del 140M-C2E-C10, Ra-ted 460 V, 7.5 HP
MOVITRAC MC07B 0037(Size 1)
30 A / 250 V 25 A max / 240 V Min ABB, Model MS132-20Rated 480 V, 10 HP
Rockwell Automation Mo-del 140M-D8E-C20, Ra-ted 460 V, 15 HP
MOVITRAC MC07B 0055(Size 2)
60 A / 250 V 40 A max / 240 V Min ABB, Model MS132-25Rated 480 V, 15 HP
Rockwell Automation Mo-del 140M-F8E-C25, Rated460 V, 20 HP
MOVITRAC MC07B 0075(Size 2)
60 A / 250 V 40 A max / 240 V Min ABB, Model MS450-40ERated 480 V, 30 HP
Rockwell Automation Mo-del 140M-F8E-C45, Rated460 V, 30 HP
MOVITRAC MC07B 0110(Size 3)
175 A / 250 V 90 A max / 240 V Min ABB, Model MS450-50ERated 480 V, 40 HP
-
MOVITRAC MC07B 0150(Size 3)
175 A / 250 V 90 A max / 240 V Min ABB, Model MS495-63ERated 480 V, 50 HP
-
MOVITRAC MC07B 0220(Size 4)
350 A / 250 V 175 A max / 240 V Min ABB, Model MS495-90ERated 480 V, 75 HP
-
MOVITRAC MC07B 0300(Size 4)
350 A / 250 V 175 A max / 240 V Min - -
1) Drives employing Type E Combination Motor Controller model MS132-12, -16, -20, -25, -32 must be installed with Current LimiterSeries S803W-SCLxxx-SR manufactured by ABB, otherwise SCCR rated 30kA/ 480 V0 Vrms
2305
6916
/DE
– 12
/201
6
1MOVITRAC® 07BInformation Regarding UL
Data sheet – Information regarding UL 7
Three Phase 380 V – 500 V Voltage RangeSCCR: 200 kA/ 500 Vwhen protected by:
SCCR: 200 kA/ 500 Vwhen protected by:
SCCR: 65 kA/ 480 Vwhen protected by:1)
SCCR: 65 kA/ 460 Vwhen protected by:
Model Non Semiconductor Fu-ses (currents are maxi-mum values)
Inverse-Time CircuitBreaker
Type E Combination Motor Controller
MOVITRAC MC07B 0003(Size 0XS)
15 A / 600 V 25 A max / 500V Min ABB, Model MS132-1.6Rated 480V, 3/4HP
Rockwell Automation Mo-del 140M-C2E-B16, Rated460V, 1HP
MOVITRAC MC07B 0004(Size 0XS)
15 A / 600 V 25 A max / 500V Min ABB, Model MS132-2.5Rated 480V, 1HP
Rockwell Automation Mo-del 140M-C2E-B25, Rated460V, 1.5HP
MOVITRAC MC07B 0005(Size 0S)
15 A / 600 V 25 A max / 500V Min ABB, Model MS132-2.5Rated 480V, 1HP
Rockwell Automation Mo-del 140M-C2E-B25, Rated460V, 1.5HP
MOVITRAC MC07B 0008(Size 0S)
15 A / 600 V 25 A max / 500V Min ABB, Model MS132-4.0Rated 480V, 2HP
Rockwell Automation Mo-del 140M-C2E-B40, Rated460V, 3HP
MOVITRAC MC07B 0011(Size 0S)
15 A / 600 V 25 A max / 500V Min ABB, Model MS132-4.0Rated 480V, 2HP
Rockwell Automation Mo-del 140M-C2E-B40, Rated460V, 3HP
MOVITRAC MC07B 0015(Size 0S)
15 A / 600 V 25 A max / 500V Min ABB, Model MS132-6.3Rated 480V, 3HP
Rockwell Automation Mo-del 140M-C2E-B63, Rated460V, 5HP
MOVITRAC MC07B 0022(Size 0L)
20 A / 600 V 25 A max / 500V Min ABB, Model MS132-6.3Rated 480V, 3HP
Rockwell Automation Mo-del 140M-C2E-B63, Rated460V, 5HP
MOVITRAC MC07B 0030(Size 0L)
20 A / 600 V 25 A max / 500V Min ABB, Model MS132-10Rated 480V, 5HP
Rockwell Automation Mo-del 140M-C2E-C10, Rated460V, 7.5HP
MOVITRAC MC07B 0040(Size 0L)
20 A / 600 V 25 A max / 500V Min ABB, Model MS132-12Rated 480V, 7.5HP
Rockwell Automation Mo-del 140M-D8E-C16, Rated460V, 10HP
MOVITRAC MC07B 0055(Size 2S)
60 A / 600 V 25 A max / 500 V Min ABB, Model MS132-16Rated 480 V, 10 HP
Rockwell Automation Mo-del 140M-D8E-C16, Rated460 V, 10 HP
MOVITRAC MC07B 0075(Size 2S)
60 A / 600 V 25 A max / 500 V Min ABB, Model MS132-20Rated 480 V, 10 HP
Rockwell Automation Mo-del 140M- D8E-C20, Ra-ted 460 V, 15 HP
MOVITRAC MC07B 0110(Size 2)
60 A / 600 V - ABB, Model MS132-32Rated 480 V, 20 HP
Rockwell Automation Mo-del 140M-F8E-C32, Rated460 V, 25 HP
MOVITRAC MC07B 0150(Size 3)
175 A / 600 V 90 A max / 500 V Min ABB, Model MS450-40ERated 480 V, 30 HP
Rockwell Automation Mo-del 140M-F8E-C45, Rated460 V, 30 HP
MOVITRAC MC07B 0220(Size 3)
175 A / 600 V 90 A max / 500 V Min ABB, Model MS495-63ERated 480 V, 50 HP
-
MOVITRAC MC07B 0300(Size 3)
175 A / 600 V 90 A max / 500 V Min ABB, Model MS495-90ERated 480 V, 75 HP
-
MOVITRAC MC07B 0370(Size 4)
350 A / 600 V 175 A max / 500 V Min ABB, Model MS495-90ERated 480 V, 75 HP
-
MOVITRAC MC07B 0450(Size 4)
350 A / 600 V 175 A max / 500 V Min - -
MOVITRAC MC07B 0550(Size 5)
225 A / 600 V 175 A max / 500 V Min - -
MOVITRAC MC07B 0750(Size 5)
225 A / 600 V 175 A max / 500 V Min - -
1) Drives employing Type E Combination Motor Controller model MS132-12, -16, -20, -25, -32 must be installed with Current LimiterSeries S803W-SCLxxx-SR manufactured by ABB, otherwise SCCR rated 30kA/ 480 Vrms
2305
6916
/DE
– 12
/201
6
1 MOVITRAC® 07BInformation Regarding UL
Data sheet – Information regarding UL8
1.1.4 Motor Overload ProtectionThe units are provided with load and speed-sensitive overload protection and thermalmemory retention upon shutdown or power loss.The trip current is adjusted to 150% of the rated motor current.
1.1.5 Ambient TemperatureThe units are suitable for an ambient temperature of 40 °C, max. 60 °C with deratedoutput current.To determine output current rating at higher than 40 °C, the output current should bederated 2.5 % per °C between 40 °C and 50 °C, and 3 % per °C between 50 °C and60 °C.Information:• Only use certified units with a limited output voltage (Vmax = DC 30 V) and limited
output current (I ≤ 8 A) as an external DC 24 V voltage source.• The UL certification only applies for the operation on voltage supply systems with
voltages to ground of max. 300 V.The UL-certification does not apply to operation on voltage supply systems with anon-grounded star point (IT system).
1.1.6 Environmental ConditionsThe units are for use in pollution degree 2 environments.
2305
6916
/DE
– 12
/201
6
1MOVITRAC® 07BWiring diagram
Data sheet – Information regarding UL 9
1.2 Wiring diagram
ON
OFF
ON
OFF
X45 X46
1 2 3 4 5 6HL ⊥
FSC11B
MOVITRAC® B
S1
7
S2
X44
−> Section "BW.. / BW..-T / BW..-P
brake rectifier connection"
PEX2X3
PE X47 8
+UZ–UZ
DG
ND
VO
24
SO
V2
4S
VI2
4
1 2 3 4
X17:
PE
PE
3 x AC 400/500 V / PE
3 x AC 230 V / PE
−> Section "Brake
rectifier connection"
X17 "Safe stop"3 x 400 V:
5.5 – 75 kW, standard
3 x 400 V:
0.55 – 4.0 kW, MC07B..-S0
3 x 230 V:
3.7 – 30 kW, standard
3 x 230 V:
0.55 – 2.2 kW, MC07B..-S0
1 x AC 230 V / N / PE
[1]
[1][1]
L1
N
PE
Switchover
I-signal -> U-signal*
* = Factory setting
}
n13 = n11 + n12
REF1
24VIO
Enable/stop*
+24V input/output
(can be switched off with P808)
0 V – +10 V 0 (4) – 20 mA
Higher-level
controller
Binary
input
Binary
outputs
Reference
binary outputs
0 – 10 V*
0 – 20 mA; 4 – 20 mAReference potential analog sinals
Error reset*
CW/stop
CCW/stop*
n11/n21*
n12/n22*
Supply voltage for TF/TH
Reference potential binary signals
Reference potential
Brake released*
Ready for operation*
Reference potential
Relay contact/malfunction*
Relay NO
Relay NC
phase
[2]
PE
8103738763[1] In sizes 1, 2S, and 2, there is no PE connection next to the power supply connection terminals and motor connection terminals
[X1]/[X2]. Use the PE terminal next to the DC link connection [X4] (only size 1 – 5). For size 0, the plate is the PE connection.[2] The MC07B..-S0 unit type must always be supplied with external voltage.23
0569
16/D
E –
12/2
016
1 MOVITRAC® 07BWiring diagram
Data sheet – Information regarding UL10
X4 is only available in sizes 1 – 5. From size 3 onwards, there are two additional PEterminals.
2305
6916
/DE
– 12
/201
6
2MOVITRAC® 07AInformation Regarding UL
Data sheet – Information regarding UL 11
2 MOVITRAC® 07A2.1 Information Regarding UL2.1.1 Field Wiring Power Terminals
• Use 75 °C copper wire only" - models with suffix 370 to 450• Use 60/75 °C copper wire only" - models with suffix 004 to 300Tighten terminals to in-lbs (Nm) as follows:Series Frame Size in-lbs NmMOVITRAC® 0S, 0M, 0L 4 0.5
1, 2S 5 0.62 13 1.53 31 3.54 120 14
2.1.2 Short Circuit Current RatingSuitable for use on a circuit capable of delivering not more than• 5,000 rms symmetrical amperes when protected by fuses as described in the ta-
bles below.– Models with suffix 005 to 300 (400 V units)– models with suffix 004 to 150 (230 V units)
• 10,000 rms symmetrical amperes when protected by fuses as described in the ta-bles below.– Models with suffix 370 to 450 (400 V units)– models with suffix 220 to 300 (230 V units)
• MOVITRAC models with suffix 005 to 450 (400 V units only).Max. voltage is limited to 500 V.
• MOVITRAC models with suffix 004 to 300 (230 V units only).Max. voltage is limited to 240 V.
2305
6916
/DE
– 12
/201
6
2 MOVITRAC® 07AInformation Regarding UL
Data sheet – Information regarding UL12
2.1.3 Branch Circuit ProtectionModel Non Semiconductor Fuses
(currents are maximum values)Short Circuit Rating
Single Phase 200 – 240 V Voltage RangeMOVITRAC MC07A 004 (Size 0S) 35A / 250 V 250 V / 5,000 AMOVITRAC MC07A 005 (Size 0S) 35A / 250 V 250 V / 5,000 AMOVITRAC MC07A 008 (Size 0S) 35A / 250 V 250 V / 5,000 AMOVITRAC MC07A 011 (Size 0L) 35A / 250 V 250 V / 5,000 AMOVITRAC MC07A 015 (Size 0L) 35A / 250 V 250 V / 5,000 AMOVITRAC MC07A 022 (Size 0L) 35A / 250 V 250 V / 5,000 AThree Phase 200 – 240 V Voltage RangeMOVITRAC MC07A 004 (Size 0S) 35A / 250 V 250 V / 5,000 AMOVITRAC MC07A 005 (Size 0S) 35A / 250 V 250 V / 5,000 AMOVITRAC MC07A 008 (Size 0S) 35A / 250 V 250 V / 5,000 AMOVITRAC MC07A 011 (Size 0L) 35A / 250 V 250 V / 5,000 AMOVITRAC MC07A 015 (Size 0L) 35A / 250 V 250 V / 5,000 AMOVITRAC MC07A 022 (Size 0L) 35A / 250 V 250 V / 5,000 AMOVITRAC MC07A 037 (Size 1) 30 A / 250 V 250 V / 5,000 AMOVITRAC MC07A 055 (Size 2) 110 A / 250 V 250 V / 5,000 AMOVITRAC MC07A 075 (Size 2) 110 A / 250 V 250 V / 5,000 AMOVITRAC MC07A 110 (Size 3) 175 A / 250 V 250 V / 5,000 AMOVITRAC MC07A 150 (Size 3) 225 A / 250 V 250 V / 5,000 AMOVITRAC MC07A 220 (Size 4) 350 A / 250 V 250 V / 10,000 AMOVITRAC MC07A 300 (Size 4) 350 A / 250 V 250 V / 10,000 AThree Phase 380 – 500 V Voltage RangeMOVITRAC MC07A 005 (Size 0M) 15A / 600 V 500 V / 5,000 AMOVITRAC MC07A 008 (Size 0M) 15A / 600 V 500 V / 5,000 AMOVITRAC MC07A 011 (Size 0M) 15A / 600 V 500 V / 5,000 AMOVITRAC MC07A 015 (Size 0L) 35A / 600 V 500 V / 5,000 AMOVITRAC MC07A 022 (Size 0L) 35A / 600 V 500 V / 5,000 AMOVITRAC MC07A 030 (Size 0L) 35A / 600 V 500 V / 5,000 AMOVITRAC MC07A 040 (Size 0L) 45A / 600 V 500 V / 5,000 AMOVITRAC MC07A 055 (Size 2S) 60 A / 600 V 500 V / 5,000 AMOVITRAC MC07A 075 (Size 2S) 60 A / 600 V 500 V / 5,000 AMOVITRAC MC07A 110 (Size 2) 110 A / 600 V 500 V / 5,000 AMOVITRAC MC07A 150 (Size 3) 175 A / 600 V 500 V / 5,000 AMOVITRAC MC07A 220 (Size 3) 175 A / 600 V 500 V / 5,000 AMOVITRAC MC07A 300 (Size 3) 225 A / 600 V 500 V / 5,000 AMOVITRAC MC07A 370 (Size 4) 350 A / 600 V 500 V / 10,000 AMOVITRAC MC07A 450 (Size 4) 350 A / 600 V 500 V / 10,000 A
2305
6916
/DE
– 12
/201
6
2MOVITRAC® 07AInformation Regarding UL
Data sheet – Information regarding UL 13
2.1.4 Motor Overload ProtectionMotor over temperature sensing is required.
2.1.5 Ambient TemperatureThe units are suitable for an ambient temperature of 40 °C, max. 60 °C with deratedoutput current.To determine output current rating at higher than 40 °C, the output current should bederated 2,5 % per °C between 40°C and 50°C and 3 % per °C between 50 °C and 60°C.Information:• The UL certification only applies for the operation on voltage supply systems with
voltages to ground of max. 300 V. The UL-certification does not apply to operationon voltage supply systems with a non-grounded star point (IT systems).
2.1.6 Environmental ConditionsThe units are for use in pollution degree 2 environments.
2305
6916
/DE
– 12
/201
6
2 MOVITRAC® 07AWiring diagram 230 V 0.37 – 2.2 kW / 400 V 0.55 – 4.0 kW
Data sheet – Information regarding UL14
2.2 Wiring diagram 230 V 0.37 – 2.2 kW / 400 V 0.55 – 4.0 kW
U W PEVX2
y
y BW...
F16
AffectsK11
P820= ON!
S 12S 11
ON
OFF*
System bus
terminating
resistor
Toggle switch
I signal V signal*
VO
24
DI0
1 C
W/S
top
DI0
2 C
CW
/Sto
p*
DI0
3 E
na
ble
*D
I04
n1
1/n
21
*
DI0
5 n
12
/n2
2*
VO
TF
DO
Ø1
-C
DO
Ø1
-NO
DO
Ø1
-NC
DO
Ø2
Bra
ke*
GN
D
AI1
1
AI1
2
GN
D
SC
11
SC
12
GN
D
SC
21
SC
22
GN
D
X10
X3PE
1 43 62 5 7 109 128 11
X11
13 1615 1814 17 19 2120
RS-485
Q
Q
Q Q
+ -
Syste
m b
us H
igh
Syste
m b
us L
ow
0..
.+1
0V
on
K1
2
0(4
)...
20
mA
I
V
V*
mA
Control
F14/F15F14/F15
K12(AC-3)
K12(AC-3)
DOØ2DOØ2
GNDGND
VACVAC
Fault*
F14/F15
1234
131415
K11(AC-3)
DOØ2
BMK
VAC
DC and ACdisconnect
BU
WH
RD
GND
F11
L1
N
PE
N PELX11-phase
F11/F12/F13
L1L2L3PE
L1 L3 PEL2X13-phase
3 x 230 V / PEAC1 x 230 V / N / PEAC
M3-phase
= Shield clamp
* = Factory setting
12345
12345
BGBGE
BGBGE
ACdisconnection
DC and ACdisconnection
WH
RD
BU
WH
RD
BU
3 x 400/500 V / PEAC
K11(AC-3)
K11(AC-3)
+R -R
Syste
m b
us H
igh
Syste
m b
us L
ow
8171455243
2305
6916
/DE
– 12
/201
6
2MOVITRAC® 07AWiring diagram 230 V 3.7 – 30 kW / 400 V 5.5 – 45 kW
Data sheet – Information regarding UL 15
2.3 Wiring diagram 230 V 3.7 – 30 kW / 400 V 5.5 – 45 kW
PE
PE
Syste
m b
us H
igh
Syste
m b
us L
ow
Syste
m b
us H
igh
Syste
m b
us L
ow
0..
.+1
0V
0(4
)...
20
mA
BW...
F16
AffectsK11
= Shield clamp
* = Factory setting
U WVX2
S 12S 11
ON
OFF*
System bus
terminating
resistor
Toggle switch
I signal V signal*
VO
24
DI0
1 C
W/S
top
DI0
2 C
CW
/Sto
p*
DI0
3 E
na
ble
*
DI0
4 n
11
/n2
1*
DI0
5 n
12
/n2
2*
VO
TF
DO
Ø1
-C
DO
Ø1
-NO
DO
Ø1
-NC
DO
Ø2
Bra
ke*
GN
D
AI1
1
AI1
2
GN
D
SC
11
SC
12
GN
D
SC
21
SC
22
GN
D
X10
X3PE
1 43 62 5 7 109 128 11
X11
13 1615 1814 17 19 2120
RS-485
+ -
on
K1
2
I
V
V*
mA
Control
F14/F15F14/F15
K12(AC-3)
K12(AC-3)
DOØ2DOØ2
GNDGND
VACVAC
Stö
rung*
F11/F12/F13
L1L2L3PE
L1 L3L2X13-phase
3 x 230 V / PEAC
M3-phase
12345
12345
BGBGE
BGBGE
ACdisconnection
DC and ACdisconnection
WH
RD
BU
WH
RD
BU
3 x 400/500 V / PEAC
F14/F15
1234
131415
K11(AC-3)
DOØ2
BMK
VAC
AC and DCdisconnection
BU
WH
RD
GND
K11(AC-3)
-R+R
P820= ON!
8171457931
2305
6916
/DE
– 12
/201
6
SEW-EURODRIVE—Driving the world
SEW-EURODRIVE GmbH & Co KGP.O. Box 302376642 BRUCHSALGERMANYPhone +49 7251 75-0Fax +49 7251 [email protected]