Download - IEC Symbols Designations
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
A-
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
16.11.2004 KFi02.11.2004 KFi
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
PROJECT DESIGN RULES & GUIDELINESCOVER PAGE
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EAA
7
Function:
Location:
Sheet:
Cont:
+=
8
A1A2
A
B
C
D
E
F
16.11.2004 KFi
KAL
A
EAC 445/2003
Rev
ABB Utilities GmbH
Format
Lang.
DCC
Sh./No.sh.Rev.Doc.No.
Ref. design.Scale
Title:Doc. kind:
Substation:
Derived from
Take over department
Responsible department
Contract No.
Revision
Approved
Prepared
Order No.
Project
en
Date Description
EAC 445/2003
GDE
OUTDOOR SUBSTATIONS
-
1HDC900037-0001
Project Design Rules & GuidelinesTechnical Description
AUTHORITY
HEAD OFFICE
ELECTRICITY
OF CYPRUS
Drawn
A
EAA
A1 /
Approved
20
A
-
16.11.2004
12.11.2004
FIRST ISSUE-REVISED
FIRST ISSUE
KFi
KFi
KAl
KAl
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
A
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
16.11.2004 KFi
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
PROJECT DESIGN RULES & GUIDELINESREVISION INDEX
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EAA
7
Function:
Location:
Sheet:
Cont:
+=
8
A2B1
A
B
C
D
E
F
REVISION INDEX
REVISION
_
A
DATE
12.11.2004
16.11.2004
NAME
KFi
KFi
FIRST ISSUE
First issue revised
DESCRIPTION
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
A
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
16.11.2004 KFi
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
PROJECT DESIGN RULES & GUIDELINESTable of contents
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EAB
7
Function:
Location:
Sheet:
Cont:
+=
8
B1D1
A
B
C
D
E
F
TABLE OF CONTENTS
FUNCTION/LOCATION
PAGE DESCRIPTION DCCPREVIOUS
STATUS
CURRENT
FUNCTION/LOCATION
PAGE DESCRIPTION
NOTE:THE SYMBOL "*" IN COLUMN "STATUS"S MEANS NEW PAGE
DCCPREVIOUS
STATUS
CURRENT
A1
A2
B1
D1
D2
D3
D4
D5
D6
D7
E1
E2
E3
E4
E5
E6
E7
E8
W1
X1
PROJECT DESIGN RULES & GUIDELINESCOVER PAGEPROJECT DESIGN RULES & GUIDELINESREVISION INDEXPROJECT DESIGN RULES & GUIDELINESTable of contentsIDENTIFICATION CODES FOR EQUIPMENTDESCRIPTIONIDENTIFICATION CODES FOR EQUIPMENTDESCRIPTIONIDENTIFICATION CODES FOR EQUIPMENTDESCRIPTIONIDENTIFICATION CODES FOR EQUIPMENTDESCRIPTIONIDENTIFICATION CODES FOR EQUIPMENTDESCRIPTIONANSI FUNCTION NUMBERSDESCRIPTIONDocument typeSheet NumberingSYMBOL OVERVIEW FOR SINGLE LINE DIAGRAMSSYMBOL OVERVIEWSYMBOL OVERVIEW FOR CIRCUIT DIAGRAMSTRANSFORMERS,MOTORS,GENERATORSSYMBOL OVERVIEW FOR CIRCUIT DIAGRAMSCONTACTORS,RELAYS,CONTACTSSYMBOL OVERVIEW FOR CIRCUIT DIAGRAMSCONTROL SWITCHESSYMBOL OVERVIEW FOR CIRCUIT DIAGRAMSLAMPS.RESISTORS,DIODES,CAPACITORS,INSTRUMENTSSYMBOL OVERVIEW FOR CIRCUIT DIAGRAMSFUSES,MCBS,CIRCUIT-BREAKERS,DISCONNECTORSSYMBOL OVERVIEW FOR INSTALLATION DRAWINGSEL. DEVICES,LAMPS,SWITCHES,OUTLETSSYMBOL OVERVIEW FOR LOGIC DRAWINGSSYMBOL OVERVIEWInternal WiringCable types & Cross sectionsInternal WiringCable types & Cross sections
EAA
EAA
EAB
EDB
EDB
EDB
EDB
EDB
EDB
EDB
EFA
EFA
EFA
EFA
EFA
EFA
EFA
EFA
EDB
EDB
- A
A
A
A
A
A
A
A
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
IDENTIFICATION CODES FOR EQUIPMENTDESCRIPTION
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EDB
7
Function:
Location:
Sheet:
Cont:
+=
8
D1D2
A
B
C
D
E
F
example:
=
=
=:N:A:A:
NN:
=
HIGH LEVELDESIGNATION
prefix sign
numbering of systems
Voltage level,higher order facilities
Subdivision of these
Switchbays,units
THE IDENTIFICATION CODE FOR ELECTRICAL EQUIPMENT IS LAID DOWN IN DIN REGULATION 40719 HARMONIZED WITH IEC PUBLICATION 61346.THIS STANDARD CONTAINS THE RULES FOR COMPLETE IDENTIFICATION CODES FOR ELECTRICAL EQUIPMENTS.ACCORDING TO THESE AN ITEM IS IDENTIFIED BY A NUMBER OF DESIGNATION BLOCKS SEPARATED FROM EACH BY MATHEMATIC SYMBOLS
N:a numerical data positionA:an alfabetic data position
NAANN
1NE00
+
+:N:A:A:
NN:
+
+
prefix sign
numbering of systems
Voltage level,higher order facilities
Subdivision of these
units
LOCATION
N01
NAANN
-
-
-:N:A:
NNN:
-
DEVICE
prefix sign
numbering of systems
Kind
Number
NANNN
K01
:
:
:
TERMINALDESIGNATION
11
11
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
IDENTIFICATION CODES FOR EQUIPMENTDESCRIPTION
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EDB
7
Function:
Location:
Sheet:
Cont:
+=
8
D2D3
A
B
C
D
E
F
Letter Code
High LevelDesignationblock
= A= B= C= D= E= F= G= H= J= K= L= M= N= P= Q= R= S= T= U= V= W= X= Y= Z
=
objects related to two or more classes of infrastructure objects classes B to Z
> 420kV380kV - < 420kV220kV - < 380kV110kV - < 220kV60kV - < 110kV45kV - < 60kV30kV - < 45kV20kV - < 30kV10kV - < 20kV5kV - < 10kV1kV - < 5kV< 1kVobjects for equipotential bondingnot usednot usednot usedFacilities for transformersFacilities for control,signalling&aux.equipmentnot usedFacilities for control roomsCentral facilities e.g.process computers,alarm systemsFacilities for telecomunications & information tasksObjects for housing or enclosing technical systemsor installations like areas & buildings
Rated voltage of plant
NAANN
Letter Code
Designationblock
= N= NA= NB= NC= ND= NE= NF= NG= NH= NJ= NK= NL= NM= NN= NP= NQ= NR= NS= NT= NU= NV= NW= NX,NY,NZ
=
< 1kVAC 500V to 1000VAC 500V to 1000VAC 500V to 1000Vnot usedAC 400/230VAC 400/230VAC 400/230VAC 400/230Vnot usedDC 220/110VDC 220/110VDC 220/110VDC 220/110Vnot usedDC 60/48VDC 60/48VDC 60/48Vnot usedDC 24/12VDC 24/12VDC 24/12Vnot used
NAANN
Rated voltage of plant
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
A
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
16.11.2004 KFi
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
IDENTIFICATION CODES FOR EQUIPMENTDESCRIPTION
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EDB
7
Function:
Location:
Sheet:
Cont:
+=
8
D3D4
A
B
C
D
E
F
Letter Code
LocationDesignationblock
+ A+ B+ C+ D+ E+ F+ G+ H+ J+ K+ L+ M+ N+ P+ Q+ R+ S+ T+ U+ V+ W+ X
+ Y+ Z
+
objects related to two or more classes of infrastructure objects classes B to Z
> 420kV380kV - < 420kV220kV - < 380kV110kV - < 220kV60kV - < 110kV45kV - < 60kV30kV - < 45kV20kV - < 30kV10kV - < 20kV5kV - < 10kV1kV - < 5kV< 1kVnot usednot usedCubicles for protective devices *1Cubicles decentralized *1Cubicles for transformersCubicles for for control,signalling&aux.systemsmarshalling cubiclescontrol room board *2Cubicles for central facilities e.g.processcomputers,alarm systemsCubicles for telecomunicationsnot used
Rated voltage of plant
NAANN
Letter Code
Designationblock
ABCDEFGHJKLMNPQRSTUVWXYZ
+
Circuit breaker accessoriesMultiply,reposition,decoupleInstrument transformer accessoriesCompressed air,hydraulicsnot usednot usednot usednot usedautomatic,closed loop controlnot usedSimulating network,voltage selectionmeasurementsystem devicesrecordermeteringProtectionSyncronizingTransformersAuxiliariesMain,secondary busbarsDisplay,operation,supervisionalarm systemnot usednot used
NAANN
Rated voltage of plant
note *1:usually not usednote *2:usually used for Objectsfor administrative or social purposes
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
A
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
16.11.2004 KFi
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
IDENTIFICATION CODES FOR EQUIPMENTDESCRIPTION
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EDB
7
Function:
Location:
Sheet:
Cont:
+=
8
D4D5
A
B
C
D
E
F
LetterCode
DeviceDesign.block
- A
- B
- C
- D
- E
- F
- G
- H
- J
- K
- L
- M
- N
- P
- Q
- R
Two or more purposes(this class is only for objects for which no main purpose can be identified)
converting an in variable (physical property,condition or event)into signal for further processing)
storing of material, energy
reserved for future standardization
providing radiant or thermal energy
protecting directly (selfacting) a flow of energy,signals, personel or equipment from dangerousor unwanted conditions including: systems and equipment for protective purposes
Initiating a flow of energy or material Generating signals used as information carriers or referencesource Producing a new kind of energy, material or product
Reserved for future standardization
Reserved for future standardization
Processing (receiving,treating and providing)signals or information (excluding objects forprotective purposes, see class F)
Reserved for future standardization
Providing mechanical energy (rotational or linearmechanical motion) for driving purposes
Reserved for future standardization
Presenting information
Controlled switching or varying a flow of energy,of signals or of material
Restricting or stabilizing motion or a flow of energy,information or material
-
Kind of item
NANN Note:table according to IEC 61346-2
-
Buchholz relay,protective relay, detector,measuring element,relay, transformer,shunt),photo cell,pilot switch,position switch,sensor, video camera,_
buffer, battery, capacitor, recorder, hard disk,memory,RAM
-
boiler, lamp, heater, laser, radiator
cathodic protection, anode, fuse, miniature circuit breaker, surge diverter, thermal overload relay
Dry cell battery,dynamo, fuel cell,generator,solar cell
-
-
All-or-nothing relay,Analogue integrated circuit,Automatic paralleling device,Binary integrated circuit,Contactor relay,CPU, delay element,electronic valve, electronic tube,feedback controller, filter,microprocessor, process computer,programmable controller, synchronizing device, time relay,transistor
-
Actuator,actuator coil,electric motor, linear motor
-
ammeter,voltmeter,indicator,display unit,signal lamp,bell,loudspeaker,printer,led,recorder,clock,counter
Circuit breaker, contactor (for power),disconnector, fuse switch, motor starter,power transistor, slip-ring, thyristor
Diode, inductor, limiter, resistor
Examples for typical electrical products
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
A
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
16.11.2004 KFi
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
IDENTIFICATION CODES FOR EQUIPMENTDESCRIPTION
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EDB
7
Function:
Location:
Sheet:
Cont:
+=
8
D5D6
A
B
C
D
E
F
LetterCode
DeviceDesign.block
- S
- T
- U
- V
- W
- X
- Y
- Z
Converting a manual operation into a signal for further processing
Conversion of energy maintaining the kind of energy Conversion of an established signalmaintaining the content of informationConversion of the form orshape of a material
Keeping objects in a defined position
Processing (treating) of material or products (including preparatory andpost-treatment)
Guiding or transporting energy, signals, materialor products from oneplace to another
Connecting objects
Reserved for future standardization
Reserved for future standardization
-
Kind of item
NANN Note:table according to IEC 61346-2
Control switch, discrepancy switch, keyboard,light pen, mouse, push-button,selector switch, set-point adjuster
AC/DC converter, amplifier, antenna,demodulator, frequency changer, measuringtransducer/transmitter, transformer,rectifier, signal converter/transformer, transducer, telephone set
Insulator
Filter
Busbar, cable, conductor, information bus, optical fibre, through bushing,
Connector, plug connector, terminal,
-
-
Examples for typical electrical products
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
ANSI FUNCTION NUMBERSDESCRIPTION
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EDB
7
Function:
Location:
Sheet:
Cont:
+=
8
D6D7
A
B
C
D
E
F
ANSI Function Numbers
CODE
5959N606779818687
2425
25A27
27N32374046
46N47
47N4950
50BF51
51/27C51/27R
OVEREXCITATION RELAY - Functions with time delay (inverse, step or definite time) for overexcitation conditions as evidenced by Volts/Hertz.
SYNC-CHECK RELAY - Functions when two ac circuits are within desired limits of frequency, phase angle and voltage to permit the paralleling of these two circuits.
AUTOMATIC SYNCHRONIZING RELAY - Acts to bring two ac circuits within desired limits of frequency, phase angle and voltage, then initiates the paralleling of these two circuits.
UNDERVOLTAGE RELAY - Functions on a given value of undervoltage.
GROUND FAULT UNDERVOLTAGE RELAY - Functions on a given value of third harmonic undervoltage.
POWER RELAY - Functions on a desired value of power flow in a given direction.
UNDERCURRENT RELAY - Functions on a given value of undercurrent.
LOSS OF FIELD RELAY - Functions on a given value of dc field current.
PHASE BALANCE CURRENT RELAY - Functions on a given degree of unbalance between the polyphase currents.
NEGATIVE SEQUENCE OVERCURRENT - Functions when the polyphase currents contain negative sequence components above a given value.
PHASE SEQUENCE VOLTAGE RELAY - Functions on a given value of polyphase voltage in the desired phase sequence.
NEGATIVE SEQUENCE VOLTAGE RELAY - Functions on a given value of the negative sequence component of the polyphase voltage.
THERMAL RELAY - Functions when the temperature of a machine, transformer or other load-carrying winding exceeds a given value.
INSTANTANEOUS OVERCURRENT RELAY - Functions without intentional time delay when the current exceeds a given value.
BREAKER FAILURE RELAY - Functions when current continues to flow after the monitored breaker should have interrupted a fault.
TIME OVERCURRENT RELAY - Functions with a definite or inverse time characteristic when the current exceeds a given value.
VOLTAGE CONTROLLED TIME OVERCURRENT RELAY - A time overcurrent relay whose pickup is adjusted by an undervoltage function.
VOLTAGE RESTRAINED TIME OVERCURRENT RELAY - A time overcurrent relay whose pickup is adjusted by an undervoltage function.
OVERVOLTAGE RELAY - Functions as a given value of overvoltage.
GROUND FAULT OVERVOLTAGE RELAY - Functions on a given value of Overvoltage at the fundamental frequency.
VOLTAGE BALANCE RELAY - Functions on a quantitative voltage difference between two circuits.
AC DIRECTIONAL OVERCURRENT RELAY - Functions on a desired value of ac overcurrent flowing in a predetermined direction.
AC RECLOSING RELAY - Controls the automatic reclosing and locking out of an ac circuit interrupter.
FREQUENCY RELAY - Functions on a predetermined value of requency (either under or over or on normal system frequency) or rate of change of frequency.
LOCKOUT RELAY - A hand or electrically reset auxiliary relay that is operated upon the occurence of abnormal conditions to maintain associated equipment or devices inoperative until it is reset.
DIFFERENTIAL PROTECTIVE RELAY - Functions on a percentage or phase angle or other quantitative difference of two currents or of some other electrical quantities.
ANSI/IEEE (C37.2))Device NumbersProtective relays are generally referred to by standard device numbers. For example, a time overcurrent relayis designated a 51 device, while an instantaneous overcurrent is a 50 device. Multifunction relays havecombinations of device numbers. A 27/59 device, for example, is a combination under/over voltage relay.Letters can be added to clarify application (87T for transformer differential, 59G for ground overvoltage).
DESCRIPTION
For a complete listing, refer to ANSI/IEEE C37.2.
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
A
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
16.11.2004 KFi
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
Document typeSheet Numbering
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EDB
7
Function:
Location:
Sheet:
Cont:
+=
8
D7E1
A
B
C
D
E
F
PageDesignation
ABCDEFGHIJKLMNOPQRSTUVWXYZ
Cover page/Revision IndexTable of contents
not usedTechnical description
Overview diagrams-Single line diagramsFunction diagrams/Flowcharts/Signal Lists
not usednot usednot usednot used
Connection DiagramsArrangement Drawings
not usednot usednot used
Part Lists/Label listnot usednot usednot usednot usednot usednot used
Cable list/Cable connection tableTerminal overview table/Terminal connection table
not usednot used
Document kind descriptionEAAEAB
EDBEFA
EFF/EFB/EFP
EFSELU
EPB
EMBEMA
Document kind Code
NOTEthese page designations are use for combined documentsmostly documents for panel and systems.The criterion is the kind of document described in the specific page.
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
SYMBOL OVERVIEW FOR SINGLE LINE DIAGRAMSSYMBOL OVERVIEW
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EFA
7
Function:
Location:
Sheet:
Cont:
+=
8
E1E2
A
B
C
D
E
F
A
V
var
cos
Hz
W
AMMETER
VOLTMETER
VARMETER
POWER FACTORMETER
FREQUENCY METER
WATTMETER
ROTARYSWITCHDISCONNECTOR
FUSE DISCONNECTOR
RESIDUAL-CURRENT OPERATED CB
DISCONNECTOR(ISOLATOR)
CIRCUIT BREAKER (CB)
FUSE SWITCHDISCONNECTOR
CURRENT T/FWITH 2 SECONDARYWINDINGSON ONE CORE
POWER TRANSFORMER
TRANSFORMERWITH VARIABLECOUPLING
CURRENT TRANSFORMER
CURRENT T/FWITH 2 CORESAND 2 SECONDARYWINDINGS
VOLTAGETRANSFORMER
3-PHASETRANSFORMERWITH SCREEN
3-PHASETRANSFORMERCWITH 3 WINDINGS
CAPACITORBANK
VOLTAGETRANSFORMER
WITH 3 WINDINGS
G
M~3
M~1
3-PHASEINDUCTION MOTORSQUIRREL CAGE
CAPACITORVOLTAGEDEVICE
CAPACITORVOLTAGEDEVICEWITH CT
1-PHASEINDUCTION MOTORSQUIRREL CAGE
GENERATOR
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
SYMBOL OVERVIEW FOR CIRCUIT DIAGRAMSTRANSFORMERS,MOTORS,GENERATORS
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EFA
7
Function:
Location:
Sheet:
Cont:
+=
8
E2E3
A
B
C
D
E
F
CURRENTTRANSFORMER(CT)
CT WITH2 SECONDARYWINDINGSON ONE CORE
CT WITHINTERMIDIATE TAP
VOLTAGETRANSFORMER(VT)
VT WITH 2SECONDARYWINDINGS
TOROIDAL CT
P
S
2-PHASE POWERTRANSFORMER
T/F WITHCENTRE TAP
1-PHASE T/FWITH SHIELDING
3-PHASE T/F WITHSHIELDINGCONNECTIONSTAR-STAR
3-PHASE T/F WITHSHIELDINGCONNECTIONDELTA-STAR
2-PHASE T/FWITH3 SECONDARY WINDINGS
3-PHASE T/FCONNECTIONDELTA-STAR
3-PHASE T/FCONNECTIONSTAR-STAR
M
~ 3M
U1 V1 W1
PE
M~3
U1
K
V1
L
W1
M
DC MOTOR
3-PHASE MOTOR3 TERMINALS
PE 3-PHASEINDUCTION MOTORWITH WOUND ROTOR
G
M~ 3
U1
V1
W1 PE
TACHO GENERATOR
3PHASEMOTORWITH PTCTHERMISTOR
~M
11-PHASEAC MOTOR
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
SYMBOL OVERVIEW FOR CIRCUIT DIAGRAMSCONTACTORS,RELAYS,CONTACTS
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EFA
7
Function:
Location:
Sheet:
Cont:
+=
8
E3E4
A
B
C
D
E
F
MAKE CONTACT
BREAK CONTACT
MAKE CONTACTEARLY CLOSE
BREAK CONTACTLATE TO OPEN
MAKE CONTACTDELAYEDWHEN OPENING
BREAK CONTACTDELAYEDWHEN CLOSING
MAKE CONTACTDELAYED WHENCLOSING
BREAK CONTACTDELAYEDWHEN OPENING
MAKE POWER CONTACT
BREAK POWER CONTACT
POSITION SWITCH/LIMIT SWITCHMAKE CONTACT
POSITION SWITCH/LIMIT SWITCHBREAK CONTACT
K?13
14
NORMALLY OPENWIPE CONTACTTO THE RIGHT
NORMALLY OPENWIPE CONTACTTO THE LEFT
WIPE CONTACTRIGHT LEFT
NORMALLYOPENEDTHERMAL CONTACT
NORMALLYCLOSEDTHERMAL CONTACT
CHANGEOVERCONTACT
CHANGEOVERCONTACTDELAYEDWHEN CLOSINGTO THE RIGHT
CHANGEOVERCONTACTFOR TESTSWITCH
CHANGEOVERCONTACTDELAYEDWHEN CLOSINGTO THE LEFT
K?A1
A2
RELAY COILOF A SLOWOPERATINGRELAY
RELAY COILOF A SLOWRELEASINGRELAY
RELAY COILOF A SLOWRELEASING& SLOWOPERATINGRELAY
RELAY COIL ~M
RELAY COILOF A MULTIFUNCTIONALRELAY
RELAY COILOF AN ACRELAY
RELAY COILOF A PULSERELAY
RELAY COILOF AN REMANENCERELAY
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
SYMBOL OVERVIEW FOR CIRCUIT DIAGRAMSCONTROL SWITCHES
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EFA
7
Function:
Location:
Sheet:
Cont:
+=
8
E4E5
A
B
C
D
E
F
NO NC
GENERAL SWITCH
PUSHBUTTON
TURN SWITCHNON AUTOMATICRETURN
PUSHBUTTONNON AUTOMATICRETURN
LIMIT SWITCHOPERATED BYROLLER
PEDAL SWITCH
NO NC
M
EMERGENCY SWITCHMUSHROOM-HEADSAFETY FEATURE
KEY SWITCHNON AUTOMATICRETURN
KEY SWITCH
MOTOROPERATIONDEVICE
MECHANICALOPERATIONDEVICE
RETAINED HANDLE
NON RETAINEDHANDLE
NO
S?13
14
S?
P
NC
S?11
12
P
FLOW SWITCH
CAM SWITCH
FLOAT SWITCH
PRESSURE SWITCH
THERMOSTAT
SWITCH OPERATEDBY STOREDMECHANICALENERGY
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
SYMBOL OVERVIEW FOR CIRCUIT DIAGRAMSLAMPS.RESISTORS,DIODES,CAPACITORS,INSTRUMENTS
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EFA
7
Function:
Location:
Sheet:
Cont:
+=
8
E5E6
A
B
C
D
E
F
LAMPSIGNAL LAMP
SIGNAL LAMPFLASHING TYPE
BEACON
INDICATORELECTROMECHANICAL/ANNUNCIATORELEMENT
LAMP WITHBUILT INTRANSFORMER
LED
CLOCK
n
Wh
TACHOMETER
GALVANOMETER
SYNCHRONOSCOPE
THERMOMETER
SIREN
BELL
Wh-METER
HORN
V
A
W
cos
Hz
VOLTMETER
AMMETER
WATTMETER
PHASE ANGLEMETER
POWER FACTORMETER
FREQUENCYMETER
COUNTER
OPERATION TIMECOUNTER
V
POTENTIOMETER`
LIGHT-DEPENDENTRESISTOR
RESISTOR
VARISTOR
VARIABLERESISTOR
HEATERELEMENT
SHUNT
RC ELEMENT
ZENER DIODE
PHOTOELECTRICCELL
BATTERY
CAPACITOR
DIODE
TRIAC
ENCODER
FILTER
PTC RESISTOR
NTC RESISTOR
THERMOCOUPLE
THYRISTOR
MEASURINGBRIDGE
FIELD WINDING
IRON COREDREACTOR
EARTING
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
SYMBOL OVERVIEW FOR CIRCUIT DIAGRAMSFUSES,MCBS,CIRCUIT-BREAKERS,DISCONNECTORS
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EFA
7
Function:
Location:
Sheet:
Cont:
+=
8
E6E7
A
B
C
D
E
F
FUSE
MINIATURECIRCUITBREAKER
FUSE DISCONNECTOR
ROTARYSWITCHDISCONNECTOR
LIGHTNING ARRESTER
EARTHING
I> I> I>
U
MOTOROPERATIONDEVICE
MECHANICALOPERATIONDEVICE
RETAINED HANDLE
NON RETAINEDHANDLE
OVERVOLTAGERELEASE
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
SYMBOL OVERVIEW FOR INSTALLATION DRAWINGSEL. DEVICES,LAMPS,SWITCHES,OUTLETS
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EFA
7
Function:
Location:
Sheet:
Cont:
+=
8
E7E8
A
B
C
D
E
F
*
**
**
* **
*
TELECOMMUNICATIONSOUTLET
AIR CONDITIONER
FREEZER
REFRIDGERATOR
WATER FREEZER
WATER HEATER
FAN
TELEPHONE CENTRE
TELEPHONEDEVICE
ANTENNA
SOCKET OUTLETWITH PROTECTIVECONTACT
SWITCH
1-POLE SWITCHWITH PILOTLIGHT
1-POLESWITCH
2-POLESWITCH
1-POLETWO WAYSWITCH
~=
FIRE ALARM
FIRE DETECTOR
MANUALLY OPERATEDCLOCK FORTIME CARDS
TIME CLOCK
CLOCK
Lx0CT=0CT
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
Internal WiringCable types & Cross sections
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EDB
7
Function:
Location:
Sheet:
Cont:
+=
8
W1X1
A
B
C
D
E
F
INTERNAL WIRING
Cross-section(mm-MIN)
2,54
2,51,5
2,5-42,5
Type Colour
RD/YE/BURD/YE/BURD/YE/BU
GYBK
GNYE
AC distributionProtection & measuring CTs secondary circuitsProtection & measuring VTs secondary circuitsDC distributionNeutral connectionsEarthing connections
Function
ACCORDING TO EAC SPEC:14-019 CHAPTER 3,29
-
AB
C
D
E
F
W
e
r
e
s
e
r
v
e
a
l
l
r
i
g
h
t
s
i
n
t
h
i
s
d
o
c
u
m
e
n
t
a
n
d
t
h
e
i
n
f
o
r
m
a
t
i
o
n
c
o
n
t
a
i
n
e
d
t
h
e
r
e
i
n
.
R
e
p
r
o
d
u
c
t
i
o
n
,
P
1
0
1
1
0
4
0
1
6
A
No
u
s
e
o
r
d
i
s
c
l
o
s
u
r
e
t
o
t
h
i
r
d
p
a
r
t
i
e
s
w
i
t
h
o
u
t
e
x
p
r
e
s
s
a
u
t
h
o
r
i
t
y
i
s
s
t
r
i
c
t
l
y
f
o
r
b
i
d
d
e
n
.
9
0
0
0
3
7
16.11.2004 KFi
Date
Revisions
1
Name
Date:
Prepared:
Checked :
Approved:
02.11.2004
KAL
KFi
KAL
2
Client Doc No:
-
ABB SA
3
Client:
EAC
Order No:
P101104016
Project name:
Contract No:
OUTDOOR SUBSTATIONS
-
EAC 445/2003
4
Item Des:
Doc Kind:
Doc.No :
1HDC900037-0001
Internal WiringCable types & Cross sections
5 6
Lang:
en
Resp.Dept:
GDE
DCC:
EDB
7
Function:
Location:
Sheet:
Cont:
+=
8
X1
A
B
C
D
E
F
Terminal Designation
-X5A-X5V-XS-X6-X7
-X1-X2-X3-X4
STRIP DESIGNATION
AC DistributionDC distributionDC internal distributionexternal digital connections
for analogue input (current)for analogue input (voltage)socket outletinternal connection with aux.equipment located in panel front door
DESCRIPTION Terminal type
M4/6-ENTRELECM4/6-ENTRELECM4/6-ENTRELEC
M4/6-ENTRELEC
M4/6-ENTRELEC
-ENTRELEC
Max cross section cable
4mm4mm4mm4mm4mm
4mm
subject to be changed according to CT calculations
notes