Transcript
Page 1: HWI FIRE PIT INSERT Stateline N-

1PERMANENT AND SEASONAL FIRE PITS

SCALE:1"=1'SECTION

SCALE: 1"=1' ELEVATION

SCALE: 1/2" = 1'PLAN - BASE LAYOUT

SCALE: 1/2: = 1'PLAN - INSERT LEVEL

NTSPERMANENT PIT STYLE REFERENCE

FIRE

MOUNT ELECTRONIC SPARKIGNITION BOX INSIDE CONCRETE BASE

PERMANENT CONTROLWIRE & CONNECTOR

REINFORCED MESH FRAME ANDWELDED WIRE MESH GRATE

STEEL WIRE MESH,IRON OXIDE FINISH

WELD TABS

SHUT OFF VALVE MOUNTED INSIDECONCRETE BASE. REFER TO MECHANICALPLANS FOR RISER AND VALVE.

(2) 2X2X2 1/4" STEEL ANGLE BASE ANCHORSWELDED TO CONE CRUSHER AND ANCHOREDTO CONCRETE BASE WITH 1/2" Ø X 4" EXP. BOLT

CAST IN PLACE CONCRETE BASE (PRECASTWOULD BE ACCEPTABLE IF SUBMITTED)

PERMANENT GAS LINE

RECYCLED CONE CRUSHERVENT IN CONCRETE BASE, SEE PLANS

RIVER ROCK FYRE STONE ASSORTEDCERAMIC FROMROCKY MOUNTAIN STOVE &FIREPLACE 970 NORTH SIMMS ST.LAKEWOOD, CO. 80401(800)[email protected] EQUAL

CONCRETE JOINTING

ELECTRICAL PULL BOX

DRAIN, SEE GRADING

GAS PULL BOX

(2) BASE ANCHORS

HWI FIRE PIT INSERT, SEE DETAIL

SCALE: 1/2" = 1'PLAN - SECURITY COVER

SCALE: 2" = 1'SECTION - SECURITY COVER & LOCK

SECURITY COVER GRATES (2)PROVIDE LOCK (1)

WELD 1/4" HALF CIRCLES (4)

SECURITY GRATES ARE SLID BELOWSTEEL HALF CIRCLES AND LOCKEDINTO PLACE

CONE CRUSHER

GRIND AND SMOOTH EXISTINGSTEEL EDGES OF CONE CRUSHERTO BE FLAT, SEE PICTURES ABOVE

EXISTING ROUGH EDGES ON THE CONE CRUSHERS

NOTES:1. OBTAIN FROM: WYOMING STEEL AND RECYCLING IRON AND METALS, INC.

(ON RESERVE).2. SHERRY RIVETT, 307.234.0314

[email protected]

NOTCH PULL BOX FORPIPING & CAULK

CONCRETE BASE

WELD (4) 1/2" WIRE HALF CIRCLE TABSTO CONE CRUSHER TO HOLD GRATE INPLACE

NOTE:1. GRATES AND STEEL HALF CIRCLES ARE INTENDED TO BE CUSTOM

FABRICATED TO BE SNUG. CONE CRUSHER SIZE MAY VARY.FABRICATOR MAY CONSIDER OPTIONS TO STREAMLINECONSTRUCTION. SUBMIT PLAN OR SCHEDULE SITE VISIT BYLANDSCAPE ARCHITECT FOR APPROVAL.

DRAIN INLET

SECURITY (NIGHT) COVER

CAST IN PLACE CONCRETEBASE - DOWEL TO WALK

2SEASONAL FIRE PIT

SCALE: 2"=1'CONCRETE BASE SECTION

NTSSEASONAL PIT STYLE REFERENCE

STEEL PLATE TABLE TOP

WELD 2" X 4"TABS (2) TO TABLE TOP

DRILL THROUGH TABS & CRUSHER, SSMACHINE BOLT AND WASHER TOSECURE TO CONE CRUSHER

TABLE TOP EXTENDS 2" FROM EDGEOF CONE CRUSHER, WHILE OVERALLSIZES MAY VARY - CUT A PERFECTCIRCLE

ONE SEASONAL FIRE PIT (THE MIDDLEPIT) TO BE UNIQUE STYLE

EASE EDGES AND SMOOTH

SCALE: 1" = 1'PLAN - SEASONAL TABLE TOP

NTSCONCRETE BASE PERSPECTIVE VIEW

SCALE: 2" = 1'SECTION - SEASONAL TABLE TOP

STEEL PLATE TABLE TOPTAB, TYPICAL

FOAM PAD AFFIXED TO BOTTOM OFTABLE TOP

CONE CRUSHER BELOW

FINISH PER SPECIFICATION

NOTES:1. CONTRACTOR PROVIDES (3) TABLE TOPS FOR

THE THREE SEASONAL FIRE PITS.2. THESE WILL BE STORED BY THE OWNER

DURING SUMMER MONTHS.3. PROVIDE PALETTE AND BLOCKING FOR SAFE

MOVING AND STORAGE.4. STEEL TABLE TOP AND OTHER NEW STEEL TO BE

CLEAR POWDER COATED FINISH PERSPECIFICATION.

5. CRUSHER CONES SHALL BE SEALED WITHPENETROL AND A POLYURETHANE SEALER

FIXED PIPING TO INSERT

#4 REBAR AT CENTER

#4 SS 6" DOWEL @ 12" O.C.

SLAB BELOW

T304 STAINLESS STEEL .047GAUGE WELDED WIRE MESHTIED TO REINFORCING MESHWITH STEEL TIES

GALVANIZED REINFORCING MESH,12MM (1/2") DIA, 150X150MM (6" X 6")OPENING

MESH STONE

3/4"X3/4" ANGLE AT BASE

CAST IN PLACE CONCRETE BASE

CENTER EXPANSION BOLTSTONE PER SPECS

THES

E D

RA

WIN

GS

AN

D T

HE

DES

IGN

S H

ERE

ILLU

STR

ATE

D A

RE

THE

SOLE

PRO

PER

TY O

F TA

LLG

RA

SS L

AN

DSC

APE

AR

CH

ITEC

TUR

E A

ND

MA

Y N

OT

BE

REP

RO

DU

CED

IN W

HO

LE O

R IN

PA

RT

WIT

HO

UT

EXPR

ESS

WR

ITTE

N P

ERM

ISSI

ON

OF

TALL

GR

ASS

LA

ND

SCA

PE A

RC

HIT

ECTU

RE.

CO

PYR

IGH

T ã

Sta

telin

e N

- o7

444

Sou

th C

ente

r Stre

etA

R C

H I

T E

C T

Sin

Cas

per,

WY

8260

130

7.26

5.36

1130

7.26

5.36

17 fa

xww

w.st

atel

ine7

.com

PROJECT NUMBER

DATE

MAY 10, 2016

DRAWN BY

DISK ID.

SHEET TITLE

SHEET NUMBER

15-015

200

SOU

TH D

AV

ID S

TREE

TC

ASP

ER, W

YO

MIN

G 8

2601

DA

VID

STR

EET

STA

TIO

N

TALLGRASS

25

13

8

LI

TT

LE

I

TA

LY

R

OA

DC

US

TE

R,

S

D

57

73

0IN

FO@

TALL

GRA

SS

LAN

DS

CA

PEA

RCH

ITEC

TURE

.CO

M60

5.51

7.18

99

605

.440

.225

4

TALL

GRA

SSLA

ND

SCA

PEA

RCH

ITEC

TURE

.CO

M

Use One Call of Wyoming to locate underground utilitiesbefore you dig. Excavators planning to dig, drill or trenchshould make the required locate request to One Call ofWyoming two working days before the planned work.

Make your locate requests by simply calling 811 (in-state)and 1-800-849-2476 outside of Wyoming. Locate

requests are accepted 24/7. The One Call service is free.www.onecallofwyoming.com

DETAILS 08

Y:\Projects\2015-028-CasperPlaza\07-CD-100%\DETAILS.dwg

3BICYCLE RACK

SCALE: 3/4" = 1'SECTION

NTSELEVATION

(4) 1/2" Ø X 4" CONCRETEEXPANSION BOLT

3500 PSI CONCRETE PAD W/ HEAVY BROOMFINISH - PROVIDE 2% MIN. CROSS SLOPE

(3/8") STEEL BIKE RACK

2" COMPACTED GRAVELBASE ROCK

COMPACTED SUBGRADE

ICON CUTOUTS - OBTAIN DWGTEMPLATE FROM LANDSCAPEARCHITECT

SCALE: 1"=1'PLANS

SINGLES FROM (1/2") STEELBIKE RACK

3" Ø CUP HOLDER CUT OUTOF TOP

1/2" STEEL BASE PLATE, TYP.

BASE PLATE

DRILL BOLT HOLES IN BASE PLATE

NOTE:1. ALL STEEL TO BE

POWDER COAT PERSPECIFICATION.

4HWI FIRE PIT INSERT

1/2" = 1'HWI BOWL ROUND PAN - FLAME SENSING WITH ELECTRONIC HOT WIRE IGNITION

*

NOTES:1. FOR USE WITH FIXED PIPING SYSTEMS ONLY.2. NOT FOR USE WITH SMALL TANKS.3. ALL ENCLOSURES REQUIRE 2 EACH 18 SQ/IN VENTS ON OPPOSING SIDES AND ADEQUATE DRAINAGE.4. RESIDENTIAL GAS PRESSURE ONLY. (NG - 7.0" WC, LP - 11.0" WC)5. MODIFICATION OF PRODUCT WILL VOID ANY CERTIFICATION AND WARRANTY.6. FOLLOW ALL MANUFACTURER INSTALLATION INSTRUCTIONS AND LOCAL CODES.7. ALL DIMENSIONS ARE CONSIDERED TRUE AND REFLECT MANUFACTURER'S SPECIFICATIONS AS OF THE REVISION DATE.8. DO NOT SCALE DRAWING.9. THESE DRAWINGS ARE FOR SIZING AND PLANNING PURPOSES. ALL INFORMATION CONTAINED HEREIN WAS CURRENT

AT THE TIME OF DEVELOPMENT. THE MANUFACTURER IS RESPONSIBLE FOR THE ACCURACY OF THE DRAWING.10. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info REFERENCE NUMBER 771-012

L-25