For nearly 20 years, based on a deep understanding of cabinets, Huawei
launched NetHos Cabinets, providing a necessary foundation for
physical data center, and a suitable environment for the equipment, with
features of efficient cooling,perfect cabling management, flexible, simple
installation, compatibility, high reliability, high security and so on, which
are widely used in various types of data centers.
New NetHos Cabinets
Safe & Reliable Cabinetscomply with IEC 60297-2 standard. The distance between
the front and the rear mounting bars is adjustable,
providing a reasonable installation layout of various types
of system equipment.
Stable Structure DesignStatic load is no less than 1200kg, to ensure stability of
cabinets.
Leading heat dissipation
Super mesh door, ventilation rate is no less than 70 %, to
ensure the smooth flow of hot and cold air.
Good compatibilityStandardized design, compatible with 19-inch rack
equipment from different mainstream manufacturers.
simply Expansion Using a dedicated Cabinets connections,which support with
side panels and without side panels mounted side by side.
Professional distribution solutionsProfessional cabinet-level power system, providing various
types of power distribution solutions.
Perfect cable managementTrough at the top of the innovation, supporting top and
bottom outlet, facilitate field wiring.
1
Safe and reliable structural design, to meet a variety of IT applications
Using steel design, to meet a variety of high-density server •
deployments, provide reliable load.
Micro- environmental management,providing equipment with a •
comfortable operating environment with temperature control design.
Unified architecture platform to facilitate installation and maintenance
unified Server and cabling cabinets, distribution cabinets, air •
condition structure architecture, engineering interface for easy
installation and maintenance.
Without Tools design, without too much space installation •
requirements, easy deployment and installation.
Compatible with other mainstream manufacturers standard •
equipment, high-density server rack deployment.
Rich and optional cabinet accessories, to ensure cabinet convenient to use
Professional cabinet-level power system to provide various types of •
power distribution solutions.
Cable and hardware installation accessories, used on demand to •
facilitate the management and operation.
A variety of wind components to ensure smooth flow of hot and •
cold air.
Cabinet - level access control to ensure high securitySupport electronic door locks (induction credit card), while •
supporting the mechanical emergency unlocking.
Support centralized monitoring and off-line run independently, to •
realize intelligent monitoring.
New NetHos Cabinets
2
Technical Specification
Item Technical parameters
model FR42612 FR47612 FR42611 FR42812
dimension (W*D*H) 600*1200*2000 600*1200*2200 600*1100*2000 800*1200*2000
installation space
per cabinet42U 47U 42U 42U
Roller Y N Y Y
Air Front and rear air duct structure, door ventilation rate is 70%.
door structure Front single door and rear double doors
surface Surface powder thickness should be no less than 60 μm, meeting the requirements of Class A environment.
material Made of high-intensity class A carbon cold rolled steel sheet and zinc-coated steel sheet with thickness of 1mm~2mm
Protection Level IP20
Environmental standards Meet the ROHS standards
Front and rear door
opening angle120º
Note: can be customized according to the specific needs of the customer.
3
Cabinet PDU
From the performance: Basic PDU&monitoring PDU
type model VoltageElectric current
(A)
Capacity(KVA)
ConfigurationMounting direction
Basic PDU16-1PH-9/0-B220V
Single-phase16 3.5
9 C13 socket, without
open space1U
Basic PDU16-1PH-7-B220V
Single-phase16 3.5
7 international socket,
7 * 6A fuse protection1U
Basic PDU16-3PH-24/6-B380V
Three-phase16 11
3×(8 C13+2 C19),
without open space0U
Basic PDU16-1PH-5-B220V
Single-phase16 3.5
5 C13, 5*10A fuse
protection1U
Basic PDU30-3PH-18/3-B208V
Three-phase30 9
3×(6 C13+1 C19),
3*16A/2P open space0U
Basic PDU32-1PH-20/4-B220V
Single-phase32 7.3
2×(10 C13+2 C19),
2*16A/1Popen space0U
Basic PDU16-3PH-24/6-B380V
Three-phase16 11
3×(8 C13+2 C19),
without open space0U
Basic PDU63-1PH-16/9-B220V
Single-phase63 12.6
2×(4 C13+2 C19)
+2×(3 C13+3 C19),
4*16A/1P open space
0U
4
Cabinet PDU
From the installation: full height PDU & half height PDU & in-cabinet PDU
type model VoltageElectric current
(A)
Capacity(KVA)
ConfigurationMounting direction
Basic PDU32-1PH-9/4-B220V
Single-phase32 7.3
2×(5个C13+2个C19),
2*16A/1Popen spacehalf height
type model VoltageElectric current
(A)
Capacity(KVA)
ConfigurationMounting direction
monitoring PDU32-1PH-20/4-M220V
Single-phase32 7.3
2×(10 C13+2 C19),
2*16A/1Popen space0U
monitoring PDU16-3PH-24/6-M 380V
Three-phase16 11
3×(8 C13+2 C19),
without open space0U
monitoring PDU32-3PH-6/12-M380V
Three-phase32 22
6×(1 C13+2 C19),
6*16A/1P Magnetic
open space
0U
5
Front door
Cabinet Rack
NO.1 2m / 2.2m Mesh doorApplies to forward wind, after the wind air scenes, to meet cabinet with high ventilation rate.
NO.2 2m / 2.2m Access control doorAccess control doors have electric locks with the access control function.
TypeDimensions
(W*D*H/mm)Weight
(kg)Color
2m Mesh door 594*22*1927 8.2 black
2.2m Mesh door 594*22*2177 8.6 black
TypeDimensions
(W*D*H/mm)Weight
(kg)Color
2m Access control door 594*22*1927 8.5 black
2.2m Access control door 594*22*2177 9.1 black
6
Front door
Side Panel
Cabinet Rack
Side panels are installed inside the cabinet to seal cabinet sides and prevent dust. Side panels can be configured based on
requirements.
NO.3 2.2m Glass doorGlass doors have high sealing performance and can meet requirements of underfloor air supply scenarios.
TypeDimensions
(W*D*H/mm)Weight
(kg)Color
2.2m Glass door 594*22*2177 20 black
TypeDimensions(W*H/mm)
Weight(kg)
Color
2m side panel 1110*800 7.5 black
2.2m side panel 1110*920 8.4 black
7
Bottom Plate
Cabinet Rack
There are two types of bottom plates: Front air supply bottom plate and Underfloor air supply bottom plate.
NO.1 Front air supply bottom plate It applies to front air supply scenarios. It ensures the sealing between the mounting bars in the front and the foreside of the cabinet for
air flow isolation.
Dimensions(W*D*H/mm)
Applicable cabinet Model(W*D*H)
Weight(kg)
567*235* 9600*1200*2000
600*1200*22001.22
NO.2 Underfloor air supply bottom plateIt uses a removable structure and applies to common precision air supply, and full enclosure scenarios.
Dimensions(W*D*H/mm)
Applicable cabinet Model(W*D*H)
Weight(kg)
600*1100*30600*1200*2000
600*1200*22008.4
NO.3 Intelligent precision air supply bottom plate Intelligent precision air supply bottom plate is mainly used for under floor air scene, used with air deflector, air damper.
Dimensions(W*D*H/mm)
Applicable cabinet Model(W*D*H)
Weight(kg)
600*1100*30 600*1200*2000
600*1200*22007.0
8
Tray
Hardware Installation
Cabinet tray is mainly used to load equipment, divided into fixed tray and adjustable tray.
NO.1 fixed trayA fixed try is used to facilitate device installation and placement. It supports standard devices, can bear a weight of 100 kg.
Dimensions(W*D*H/mm)
Weight(kg)
Load capacity(kg)
483*622*62 3.37 100
Rail
L - shaped guide rail for both sides of the cabinet, a standard design, can withstand the fixed guide mobile device or equipment.
Dimensions(W*D*H/mm)
Weight(kg)
Load capacity(kg)
Depth range(mm)
42*622*37 0.72 50 645~720
NO.2 adjustable trayAdjustable tray used to load equipment, according to the square hole depth adjustment.
Dimensions(W*D*H/mm)
Weight(kg)
Load capacity(kg)
Depth range(mm)
481*870*43.6 5.6 100 570~870
9
PDU Mounting Plate
Hardware Installation
The PDU mounting plate support PDU installation. The cabinet supports PDU screw installation and without-tool mounting.
PDU mounting plate including full-height and half-height PDU mounting plate.
NO.1 full-height PDU mounting plateIt is used for the installation of full height PDUs. Full height PDUs are clamped onto the mounting plates or secured to the plates by
using screws, making the installation simple and easy. Both 2 m and 2.2 m full height PDU mounting plates use a segmental structure.
NO.2 half-height PDU mounting plateIt is used for the installation of half height PDUs. Half height PDUs are clamped onto the mounting plates or secured to the plates by
using screws. 2.0 m mounting plates use a unitary design and support the installation of vertical cabling modules. 2.2 m mounting
plates use a three-segment design.
Type Dimensions (W*H/mm) Structure Model Weight (kg)
Full height PDU
mounting plate
Upper segment / Lower
segment: 125*200
Upper-lower two-
segment0.537
Upper segment / Lower
segment: 125*50
Upper-lower two-
segment1.09
Type Dimensions (W*H/mm) Structure Model Weight (kg)
2.0 m half height PDU
mounting plate125*1900 Unitary 2.89
Type Dimensions (W*H/mm) Structure Model Weight (kg)
2.2 m half height PDU
mounting plate
Upper segment: 125*350
Middle segment: 125*450
Lower segment: 125*300
Upper-middle-lower
three-segment1.5
10
Cabling Unit
Cable Management
Cabinet horizontal cabling management, and a decorative tool.
Cable Ring
A cable fastener is installed on a vertical column in the cabinet for vertical-cable management.
Dimensions (W*D*H/mm) Weight (kg)
48 *188.6 *50 0.163
Dimensions (W*D*H/mm)
Weight (kg) Trace amount Space Occupied
482.6 *91 *43.6 0.56 48 *6 square thread 1U
11
Depth-directed Cable Manager
Cabling Tray
Cable Management
A depth-directed cable manager is used for depth-directed cabling. Its drawer design supports various mounting bar distances.
A cabling tray is used for forward and backward cabling. It uses unique mounting ears to facilitate device installation.
Dimensions (W*H) Weight (kg) Depth range (mm)
50*36 0.537 442.5~742.5
Dimensions (W*D*H) Weight (kg) Space Occupied
482.6*250*43.6 1.89 1U
12
Dummy Panel
"L" Airtight Bar
Airflow Management
If certain space in the cabinet is not occupied, install filler panels in that position to prevent wind and beautify the cabinet.
“L” Airtight Bar is used for sealing.
NO.1 1U dummy panel1 U dummy panel occupied by 1U space.
NO.1 2U dummy panel2 U dummy panel occupied by 2U space.
Type Dimensions (W*D*H) Weight(kg)
1U dummy Panel 482.6*25*44 0.12
Type Dimensions (W*D*H) Weight (kg)
2U dummy Panel 482.6*25*88.5 0.216
Type Dimensions (W*D*H) Weight (kg)
“L”Airtight Bar 598.5 *10*72.5 0.656
13
Air Deflector
Airflow Management
Air deflectors apply to underfloor air supply scenarios. Cabinet air deflectors are classified into the following two types
based on air supply modes: Common precision air supply air deflector & Intelligent precision air supply air deflector.
NO.1 Common precision air supply air deflectorIt applies to common precision air supply scenarios and used with an underfloor air supply bottom plate.
Dimensions (W*D*H) Weight (kg) Space Occupied
482.6*332*138 2.4 3U
NO.2 Intelligent precision air supply air deflectorIt applies to intelligent precision air supply scenarios and used with an air valve and an underfloor air supply bottom plate.
Dimensions (W*D*H) Weight (kg) Space Occupied
442*709.5*130.6 4.26 3U
NO.3 Air damperAir damper used with intelligent precision air supply air deflector, realize intelligent precision air supply.
Dimensions (W*D*H/mm) Input Voltage (V DC) Operating Temperature (ºC)
442*650*86 24 5~40
14
Other Unit
Cabinet Bracket
Cabinets supporting bracket for the booster and the supporting cabinet.
width (mm) depth (mm)Applicable anti-static floor
height (mm)
600 1200 600
Copper Ground Bar
A copper ground bar is used for the grounding of devices inside the cabinet.
There are M6 and M8 terminals on a copper bar. M6 terminal ports are used for device grounding, and M8 for leading out
ground cables. Insulators can be used to isolate the copper bar from the cabinet to ensure high grounding reliability. Users
can configure insulators as required.
Dimensions (W*D*H) Installation Mode Number of Terminals
490*3*30It can be horizontally installed on
mounting bars.19*M6+2*M8
Door Status Sensor
A door status sensor can be installed on the front door or rear door of the cabinet. It generates an alarm when detecting
abnormal cabinet door status. Door status sensors can be configured based on customers' requirements.
Rated current (mA)
Rated power(W)
Securing mode
Switch form color
500 10 Screw Normally open
White acrylonitrile
butadiene styrene (ABS)
engineering plastic
15
Other Unit
Lighting System Fittings
Lighting System Fitting achieves cabinet lighting. Light system fittings include a daylight lamp and a touch switch.
NO.1 Daylight LampLED lamps are used for lighting in the cabinet. Each server is configured with two LED lamps on the top at the two ends of the cabinet.
NO.2 Touch SwitchA touch switch automatically turns on the daylight lamp when detecting that cabinet doors are open and turns it off when the doors
are closed. It uses advanced NC contacts with high sensitivity.
Installation mode Securing mode Power (W) Service life (h)
Roof-mounted or wall-
mounted
With buckles (delivered
with the lamp)2~6 ≥10000
Rated working voltage (V)
Rated working current (A)
Installation modeService life
(times)
220 10
Mechanical screw
installation, such as surface
mounting technology
(SMT) and add-in)
100000
16
Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved.
General Disclaimer
The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Industrial Base
Bantian Longgang
Shenzhen 518129, P.R. China
Tel: +86-755-28780808
Version No.: M3-035748-20130530-C-2.0
www.huawei.com
About Network Energy of Huawei
Based on the deep understanding about telecommunication in a long term of 20 years, and the construction
and maintenance experience of more than 1.5 million global telecommunication sites, Huawei network energy
product line adheres the ‘4S’ concepts of ‘Simple, Scalable, Smart, Saving’, and commits to providing customers
the world's leading network energy solutions.
The network energy product line has two main businesses of site energy and data center energy. We are making
stable, green energy and infrastructure for customers in ICT field, building a solid foundation for excellence
networks, protecting customers’ long term investment on energy and infrastructure.
About Huawei
Huawei is a leading global ICT solutions provider. Through our dedication to customer-centric innovation and
strong partnerships, we have established end-to-end capabilities and strengths across the carrier networks,
enterprise, consumer, and cloud computing fields. We are committed to creating maximum value for telecom
carriers, enterprises and consumers by providing competitive ICT solutions and services. Our products and
solutions have been deployed in over 140 countries, serving more than one third of the world's population.