HEART-LUNG BYPASS UNITS; EXTRACORPOREAL
PERFUSION; OXYGENATORS, EXTRACORPOREAL MEMBRANE
Member:1. Ahmad Rafiqan Bin Nayan2. Muhammad Irfan Bin Alias3. Mohammad Al-Karim Tayasneh4. Mohd Izzad Samir Bin Iskandar
![Page 2: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/2.jpg)
![Page 3: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/3.jpg)
What is Heart-lung Bypass unit?
External systems that provide circulation, oxygenation, and filtration of theblood as a temporary substitute for circulatory and pulmonary function.
![Page 4: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/4.jpg)
Type of Medical Purpose
Often used for open-heart surgery, such as coronary artery bypass grafting and cardiac valve replacement.
In some cases, used for extracorporeal membrane oxygenation (ECMO) in patients with respiratory distress syndrome or with respiratory insufficiency due to pneumonia, smoke inhalation, or other causes.
Technique of providing both cardiac and respiratory
support oxygen to patients whose heart and
lungs are so severely diseased or damaged that they can no longer serve
their function.
![Page 5: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/5.jpg)
Block diagram of Heart-lung Bypass Unit
![Page 6: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/6.jpg)
Process flow…
![Page 7: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/7.jpg)
Principle of Operation
During bypass, the patient is heparinized to prevent blood from clotting within the heart-lung bypass circuit. (After bypass, anticoagulation must be reversed by protamine sulfate)
Heart is infused with a cardioplegic chemical solution (e.g potassium chloride) to stop its rhythmic contractions and reduce its metabolic requirements so as to avoid ischemic damage to the myocardium.
![Page 8: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/8.jpg)
The blood flows to the oxygenator/heat exchanger for oxygenation, carbon dioxide removal, temperature regulation, and any necessary anesthetic exchanges.
Blood that pools in the surgical site is suctioned and collected in a cardiotomy reservoir, where it is filtered, defoamed, and either pumped or drained to the oxygenator.
The oxygenated blood is then returned to the patient, typically through the aorta, bypassing the heart and lungs.
![Page 9: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/9.jpg)
Component
Extracorporeal perfusion pumps
Oxygenator
Perfusion monitoring and peripheral equipment
Closed-circuit systems
![Page 10: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/10.jpg)
Extracorporeal perfusion pumps
Roller pump Centrifugal pump
![Page 11: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/11.jpg)
Roller pumps: The pumps are designed so that one of
the rollers is always in contact with the pump-head tubing, compressing it and forcing the blood forward.
Pump-head occlusion is manually adjusted by the operator. Some pumps can provide pulsatile flow.
![Page 12: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/12.jpg)
Advantages :1. Require low volume of blood for priming.2. The association with minimal
biocompatibility problems (because the tubing is the only surface that contacts the blood)
3. A low haemolysis rate (possibly due to the lack of blood backflow or turbulence).
Blood ruptur
e
![Page 13: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/13.jpg)
Disadvantages: 1. Tubing will crack or release plastic
fragments that can become particulate emboli.
2. In the event of a tube blockage, there is a possibility that the pump will continue to operate and cause the tubing to rupture.
![Page 14: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/14.jpg)
Centrifugal pump: Uses centrifugal force to move blood
through the system. Spinning cones or rotating fins create a vortex and force blood centrifugally through a port in the periphery of the pump head.
Flow output must be measured using a noninvasive sensor or a disposable probe inserted into the arterial line.
![Page 15: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/15.jpg)
Advantage : Reducing the risk of generating
particulate matter in the blood. Provide protection against over
pressurization of the system in case of tubing occlusion.
Air-lock system- preventing air from being administered to the patient. If there is air, the filter will remove the air as the pump will continue function.
![Page 16: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/16.jpg)
Disadvantage : Non-occlusive: not prevent blood backflow
from the patient if the pump stops, adding to the risk of air entry into the circulation.
Generally: Both a backup arterial pump and a
connection to an emergency power system are necessary to ensure reliable pump operation.
A hand crank for manual pumping is recommended as an additional backup as it can provide the high rotational speeds required by centrifugal pumps.
![Page 17: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/17.jpg)
Oxygenation
![Page 18: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/18.jpg)
Example :Membrane oxygenator. These devices usually have an integral heat exchanger to control the temperature of the blood.
Oxygenator must be primed before use with lactated Ringer’s solution of 5% dextrose, to remove air pockets and bubbles from the bypass circuit.
Consist of a gas-permeable membrane separating a thin layer of blood from the oxygenating gas.
![Page 19: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/19.jpg)
Three major types of membrane oxygenators are PLATE, COIL, and HOLLOW FIBER.
As a safety precaution, arterial blood is usually pumped through an in-line arterial filter, which helps trap particulate matter and gaseous emboli before they reach the patient. If the filter becomes clogged, the blood can be diverted through an arterial-line shunt that has its own filter.
After oxygenation and filtration, the blood is pumped into the body through a cannula placed in the ascending aort or femoral artery at a rate of four to six liters per minute (L/min), depending on the patient’s physiologic requirements.
![Page 20: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/20.jpg)
Perfusion monitoring and peripheral equipment
To maintain the desired temperature in the heat exchanger water mixer regulates delivery of warming and
cooling water mixer is typically part of the pump console
and includes a thermometer and a backup pressure-relief valve
A separate electric water heater/cooler can be used instead of a mixer
![Page 21: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/21.jpg)
Thermistor probes are placed at various points on the patient and in the extracorporeal circuit
Blood gases can be monitored from drawn samples, by an in-line differential oxygen monitor
Pressure monitors record left atrial, pulmonary artery, and systemic arterial pressures
Electronic safety devices have been incorporated into heart-lung bypass units, with varying degrees of acceptance
![Page 22: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/22.jpg)
Most manufacturers offer ultrasonic bubble detectors, which use an ultrasonic transducer and detector to shut down the pumps automatically when gaseous emboli are detected in the arterial line.
Level detectors-which alarm when blood falls below acceptable levels in the oxygenator, cardiotomy reservoir, or other components.
Some centrifugal pumps include a backflow alarm to alert the clinician to retrograde blood flow within the system.
![Page 23: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/23.jpg)
Closed-circuit systems
Minimally invasive closed-circuit systems (also called mini-bypass systems) are designed to be used intermittently during beating-heart surgery.
Incorporates the pump, filter, and oxygenator in one housing and is stationed on the main console.
It small, use shorter tubing and can be placed closer to the patient as result patient’s blood spends less time outside the body
![Page 24: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/24.jpg)
less priming is required- this decreased extracorporeal blood, coupled with less diluted blood, results in less blood damage.
![Page 25: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/25.jpg)
REPORTED PROBLEM
EMBOLISM IMPROPER OR DEFECTIVE CONNECTION
IN TUBING FAILURE OF SYSTEM HARDWARE PROBLEM WITH CERTAIN ANCILLARY
PORTION OF EXTRACORPORCEAL CIRCUITS
INTERFERENCE BETWEEN HEART LUNG MACHINE AND BISPECTRAL INDEX(BIS) MONITOR
![Page 26: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/26.jpg)
PURCHASE CONSIDERATION
ARTERIAL PUMP- ROLLER OR CENTRIFUNGAL CONFIGURATION
1 0R 2 SUCTION PUMP CARDIOPLEGIA PUMP BACKUP ARTERIAL PUMP-EMERGENCY
POWER SUPPLY MANUAL CRANK DISPOSABLE OXYGENATOR
![Page 27: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/27.jpg)
OTHER CONSIDERATION
DEGREE OF MODULARITY OF EACH SYSTEM
PROCEDURE ROOM ELECTRICALY CIRCUITRY AND CAPACITY BE ASSESSED
![Page 28: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/28.jpg)
ENVIRONMENT CONSIDERATION
GREEN SHIPPING AND PRODUCTION METHOD
ENERGY EFFICIENCY BIS(2-ethyhexly)phthalate (DEHP)- FREE
DISPOSABLE
![Page 29: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/29.jpg)
STAGE OF DEVELOPMENT
DISPOSABLE COMPONENT
HEPARIN-COATED
EXTRACORPOREAL
COMPUTERIZED PERFUSION CONTROLLER
RATCHED STYLE HANDPIECE AND
ADJUSTABLE
CARDIOPULMONARY BYPASSS SYSTEM
![Page 30: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/30.jpg)
Biomedical Benchmark
![Page 31: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/31.jpg)
IPM Frequency
4 times per year
![Page 32: Heart lung by pass unit](https://reader033.vdocuments.us/reader033/viewer/2022061120/54660703af79596e458b4cff/html5/thumbnails/32.jpg)