Download - HAL S3201 - Brochure 2011_noprices (1)
®GaumardSimulators for Health Care Education
HAL® S3201
. . . a proven tether less s imulator• SimulationMadeEasyTM
• Fullyresponsiveintransit
•Wirelessstreamingaudio
• Automaticorinstructorcontrol
HAL® S3201HAL S3201combines thebestofsimulationtechnologiesinanaffordablepackage.
EasytoUseOur intuitiveandpowerful3Duserinterfacedefines...SimulationMadeEasyTM
ReliableProven HALtechnologysoruggeditwasawardedanairworthinesscertificatebytheUSArmy
UseRealDevicesConnectdirectlytoarealventilator.Useareal12leadECGmonitor,realOsatmonitors,BPcuffs,defibrillatorsorexternalcardiacpacemakers.
AffordableGaumarddedicatesitstalentstoprovidingsimulatorsataffordableprices.Thisprincipleremainsastruetodayasitwasover50yearsago.
TetherlessTetherlesstechnology,pioneeredbyGaumardin2004,allowsthecommunications,compressor,andpowersupplytobeinsidethesimulator,eliminatingexternaltubes,wiresandcompressors.
Advanced“Beyondcomplexityliessimplicity”...HALtechnologyissoadvanceditisactuallyeasytouse
Pro+|Recordinganddebriefingsystem
Pro+issuppliedwithtwowirelessandonewiredcamera.Capturemultiplevideo(withwiredorwirelesscameras),audio,andpatientmonitors,aswellasthesimulatorlogfile.ControlbothsimulationandrecordingsimultaneouslyusingonePC.
Dynamicairwayandlungcompliance
Changelungcompliance/airwayresistanceduringscenarioandseeresultsonarealventilator.HALholdsPEEP,triggerstheventilator,andexhalesrealandmeasurableCO2.Useourpre-programmedpathologiesorcreateyourown.
12leadECGwithintegratedMImodel
DisplayandinterpretHAL’s12leadECGusingyourreal12leadmonitor.ChoosefromthethousandsofcardiacrhythmsinourECGlibraryorcreateyourownwithourrhythmeditor.UseintegratedMImoduletospecifyocclusions,ischemiaornecrosis.
Drugrecognition
Identifiesdrugtypeandvolumeinjectedintoveinsofrighthandandforearm.Useourformularyoryours.Effectisdeterminedbyphysiologicmodel,updatingthesimulatedvitalsignsmonitor.
AutomaticMode
Respondstocaregiverorinstructoractions;topharmacologicintervention,toinjury;ortocardiacandrespiratoryevents
ReactiveEyes
HALhasblinkingeyeswithphotosensitivepupils.Dilation,reactivity,andblinkratecanbecontrolledautomaticallyorbytheinstructor.
TabletPCHALincludesa12inchtouchscreentabletPCwithstyluscontrol,“bump”caseandscenarios
TheMonitors
• Includes17inchtouchscreenvirtualmonitororupgradetoa12inchtabletvirtualmonitor
• Customizeeachtraceindependently;userscansetalarms,andtimescales.
• Displayupto12numericvaluesincludingHR,ABP,CVP,PAWP,NIRP,CCO,SpO2,SvO2,RR,EtCO2,temperature,andtime
• Selectupto12dynamicwaveformsincludingECGLeadI,II,III,aVR,aVL,aVF,V1,V2,V3,V4,V5,V6,AVP,CVP,PAWP,pulse,CCO,SvO2,respiration,capnography.
• Shareimagessuchasx-rays,CTscans,labresults,orevenmultimediapresentationsasthescenarioprogresses
WirelessStreamingAudio
BethevoiceofHALandhearcaregiverresponses.Createandstorevocalresponsesorselectfromapre-recordedvocalmenu.
MeasureOSATusingrealoximeter
MeasureBloodPressureusingrealcuff
OralandNasalIntubationReactiveEyes
CentralCyanosis
Defibrillate,cardiovertandpaceusingrealdevices
12LeadECGDynamicAirwayandLungCompliance
AutomaticChestRise BilateralIVarms
TheSoftware|GIGATM
Ourintuitiveandpowerfulsoftwareofferseaseofuseandtheflexibilityrequiredbythemostdemandingusers
GIGA Features
•Basicviewprovideswindowsforthe3Dmodelofthesimulator,acompletelyconfigurablevitalsignsmonitorandanactivitieslog.• 3Dimagecanberotatedorenlarged;theskinremovedandphysiologicparametersaccessedtochangeanyelementsofapowerfulphysiologicengine.• Physiologicparametergroupsincludeairway,breathing,cardiac,cephalicandcirculation.Moveeachaboutthestatuspanel.• Expandwindowstoincludestatus,palettes,scenario,branchingscenario,actions,log,monitors,CPRrecorder,speech,medication,andquickmeds.• Specifyonlyfrequentlyusedparametersorbeasdetailedasyouwish.
Realisticsurgicaltrachea
General•Availableinethnicskintones• Tetherlessandfullyresponsiveevenwhilebeingtransported•Poweredfromaninternalrechargeablebatteryorwalloutlet•Batteryoperatesthesimulatorupto5hours• SimulatorreceivescommandsfromawirelesstabletPCandoperatesatdistancesupto300meters• Simulatormaybeusedoutdoorsorindoors;becoveredwithablanketorplacedinaNATOlitter• Simulatorcanoperateautomaticallyusinga“physiologic”modelorbytheinstructor•Optionalprogrammablebleedingarmsandlegs• Instructionmanualwithbothbasicandadvancedinteractivescenarios•Usepreprogrammedscenarios,modifythemorcreateyourownquicklyandeasily• Installationandtrainingworldwide•SimulationMadeEasyTM
Airway• Programmableairway:tongueedema,laryngospasm,andpharyngealswelling•Multipleupperairwaysoundssynchronizedwithbreathing•Nasalororalintubation•Rightmainstemintubation•Sensorsdetectdepthofintubation•Airwaymaybeobstructed•Blockrightlung,leftlung,orbothlungs•Headtilt/chinlift•Jawthrust•Simulatedsuctioningtechniquescanbepracticed•Bag-Valve-MaskVentilation•Placementofconventionalairwayadjuncts•EndotrachealintubationusingconventionalETTs•Retrogradeintubation•Sellickmaneuverbringsvocalcordsintoview•Realisticsurgicaltracheaallowstracheostomyorneedlecricothyrotomy•Tracheostomycareandsuctioning
Breathing•Controlrateanddepthofrespirationandobservechestrise•Automaticchestriseissynchronizedwithrespiratorypatterns•Selectindependentlungsounds:upperrightfrontandback;upperleftfrontanback;lowerrightfrontandback;lowerleftfrontandback•Chestriseandlungsoundsaresynchronizedwithselectablebreathingpatterns•AccommodatesassistedventilationincludingBVMandmechanicalsupport•Ventilationsaremeasuredandlogged•GastricdistensionwithexcessiveBVMventilation•Detectionandloggingofventilationsandcompressions•Simulatedspontaneousbreathing•CO2onexhalation(4levels)usingreplaceablecartridgemountedinsidethesimulator•Variablerespiratoryratesandinspiratory/expiratoryratios•Attachtorealmechanicalventilators•Bilateralchestriseandfall•Unilateralchestrisesimulatespneumothoraces•Normalandabnormalbreathsounds•Anteriorandposteriorauscultationsites•Bilateralneedledecompressionatsecondintercostal•DynamicAirwayandLungcompliance/resistance- Tenlevelsofstaticcompliance, 15-50ml/cmH2O- Tenlevelsofairwayresistance- Useinconventionalventilationmodes- HoldsPEEPfrom5to20cmH2O- ExhalesrealandmeasurableCO2- Varylungmechanicsthroughoutscenario- Receiverealtimefeedbackfromrealmechanicalventilator
- Capableofassistingtheventilatoratvariablerespiratoryrate
- Complianceandresistancecanbevariedwhileconnectedtotheventilator
Cardiac •ECGsaregeneratedinrealtimewithphysiologicvariationsneverrepeatingtextbookpatterns•HeartsoundsmaybeauscultatedandaresynchronizedwithECG•ECGrhythmsshownforeachofthe12leads•Viewdynamicratherthanstatic12leadrhythms• 12LeadECGwithintegratedMImodel- Useyourreal12leadmonitor- ExtensiveHALECGlibrary- Specifyother12leadECGsusingoureditor- UseintegratedMImoduletospecifyocclusions,ischemiaornecrosis
Circulation •Measurebloodpressurebypalpationorauscultation•UserealBPcuffratherthana“virtual”cufftomeasurebloodpressure•Korotkoffsoundsaudiblebetweensystolicanddiastolicpressures•Oxygensaturationdetectedusingrealmonitorsratherthana“virtual”value•PulsesitessynchronizedwithBPandheartrate•BilateralIVarmswithfill/drainsites•Realisticflashback•SubQandIMinjectionsites•Intraosseousaccessattibia•Chestcompressionsaremeasuredandlogged•ChestcompressionsgeneratepalpablebloodpressurewaveformandECGartifacts•ECGmonitoringusingrealdevices•Defibrillate,cardiovertandpaceusingrealdevices•Multipleheartsounds,ratesandintensities•ECGrhythmsaregeneratedinrealtime•HeartsoundssynchronizedwithECG•Dynamicratherthanstatic12leadECGdisplay•Pacingmaybepracticedanteriorally•Bilateralcarotid,radial,brachial,femoral,poplitealandpedalpulsessynchronizedwithECG•Pulsesvarywithbloodpressure,arecontinuousandsynchronizedwiththeECGevenduringapacedrhythm
Instructor or Automatic Mode•Intuitiveinterfaceandautomaticitymakessimulationeasy•Vitalsignsaregeneratedinrealtime•Druglibrarywithmedications•Useofmedicationschangeconditionsinrealtimemimickingrealclinicalsituations
Drug Recognition System•Identifiesdrugtypeandvolumeinjectedintoveinsoftherighthandandforearm•Suppliedwith100syringeshavingwirelesstags•Usedrugsfromlibraryorchoosetomodelotherdrugsusingsoftwaretemplate•Physiologicmodelsupdatesimulatedvitalsignsmonitors•Additionalpacksof20syringeswithtagsavailable•22gaugeneedlerecommended;largerneedleswilldecreasevenouslife•Suppliedwitheasilyreplaceableveins
Neural Responses•Eyesarecontrolledautomaticallybyphysiologicmodelordirectlybytheinstructor•Eyesopenandclose•Selectblinkrate•Selectpupillaryresponsetolight
Speech•Wirelessstreamingaudio•Prerecordedsounds•Createandstorevocalresponsesinanylanguage•Instructorcansimulatepatient’svoiceandlistentocaregiversconversationwirelessly•Bethevoiceofthesimulatorandhearresponsesatdistancesupto50meters
Vital Signs Monitor•ControlledviawirelesstabletPC•Simulatedvitalsigns•Useselectedconfigurationorcreateyourownconfigurationtomimictherealmonitorsusedinyourfacility•Customizealarms•Easytooperateandcontrol•Reflectsimulator’sconditionduringthescenario•Shareimagessuchasultrasounds,CTscans,labresults•Touchscreencontrol•Monitorcanbeconfiguredbytheinstructortosuitthescenario•Displayupto12numericparameters•Selectupto12dynamicwaveforms
Articulation and Movement•Seizure/convulsions•Realisticrotationoftheshoulderandhipjoints•Legsbendattheknees•Supineorsemi-recumbentpositions
Other•Centralcyanosis•FillbladderandperformFoleycatheterization•Interchangeablegenitalia•Insertfeedingtubes•Auscultatebowelsounds•Remainsfullyfunctionalevenwhileintransit• Softcarryingcase
User Interface •Sensorstrackstudentactions•Changesinconditionandcareprovidedaretimestampedandlogged•Viewtheactionsofupto6careprovidersusingaresponsivemenuorwritenarrative•Generateandsharediagnosticlabresults•Linkswithoptionalrecordinganddebriefingsystemintegratingtheeventlogwithcamerasandpatientmonitor•SuppliedwithwirelesstabletPC•Interactive“Physiologic”modeling•26preprogrammedscenarioswhichcanbemodifiedbytheinstructorevenduringthescenario•Createyourownscenarios-add/edit•Changesimulator’sconditionduringthescenario•Optionalintegratedthreecamerarecordinganddebriefingsystemavailable- ControlbothsimulationandrecordingsimultaneouslyusingonePC
-Capturemultiplevideo,audio,andpatientmonitors,aswellassimulatorlogfilefordebriefing
S3201 |HAL
Patented;otherpatentspending
Optional Add-Ons1
Pro+ recording and debriefing system 2
S3201.211 |
Traumatic leg amputation
S3201.004 |
Traumatic arm amputation
S3201.005 |
Upgrade to 12 inch tablet virtual monitor
S3201.003 |
Toll Free: USA 800.882.6655 - Worldwide: 305.971.3790 - Fax: 305.667.6085Email: [email protected] - www.gaumard.com - Gaumard Scientific, 2011
HAL®S3201...apartofGaumard’sgrowingfamilyoftetherlesssimulators
1 Price applicable with initial purchase. Contact us for upgrade pricing2 Pro+ recording and debriefing system includes two wireless cameras, one wired camera,
and access to the Pro+ software. Pro+ works in the same tablet used to control simulator
MADE IN AMERICA