Gerd Gendt and Thomas NischanGeoForschungsZentrum Potsdam
Combination of reprocessed orbit, clock and ERP products
![Page 2: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/2.jpg)
2
Status of IGS Final Products before ReprocessingOrbits (with 15-minute clocks) & ERP products since 1994
SINEX (since 1996; ERP since June 1999)
Combined Clocks with 5-minute sampling since Oct 2000 (week 1085)with 30-second sampling since Dec 2006 (week 1406
ACs:
# in Combi
COD ESA EMR JPL
8
8
8
6
y
3
y
y
y
y
Clocks y y y y y y - -
y
-y
y
y
y
y
GFZ MIT NGS SIO
SINEX y y y y
y
y
-
y
ERP y y y y
Orbits y y y y
Clk 30s - - y -
: Reprocessing contribution
![Page 3: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/3.jpg)
3
Reprocessing
Test periodJan to Apr 2000, 14 GPS weeks (1042 to 1056)Jun to Dec 2007, 30 GPS weeks (1430 to 1459) (Check with latest official products)
[NGS last 10 weeks used as interval for all statistics]
ESA GFZ* MIT NGS PDR SIO # in Cmby (y)
yy--
y6663
yClocks y y y - - 6
---
yyy
-
RouCmbSINEX y y y 8ERP y y y 8Orbits y y y 8
Clk 30s - - y 3
GoalGeneration of RF with consistent ERP (contribution to ITRF)Consistent orbits referred to given RF Consistent clocks for PPP in given RF (now possible after Oct 2000 only)
*not 2000 ~COD
![Page 4: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/4.jpg)
4
Stability of orbit RFNumber of stations defining the IGS05
Note: AC’s frame rotation from SINEX combination will be used to align the orbits.
Consistency between orbits and SINEX solution is important, and isdegrading in the early years because of the reduced number of RF stations
![Page 5: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/5.jpg)
5
Orbits – Differences to combination
Repro quality comparable with operational product in 2007
All orbits (including operational IGS Finals) are compared to combined repro orbits.R
epro
Ope
ratio
nal
IGF: 29 ± 5 mm IGF: 8 ± 2 mm
Improvements for 2000
![Page 6: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/6.jpg)
6
Orbits – Long Arc Fit7-day long arc fit through all orbits, including the combined ones
Rep
ro
IG1: 27 ± 5 mmIG1: 51 ± 9 mm
IGS: 27 ± 4 mmIGS: 62 ± 18 mm
Ope
ratio
nal
![Page 7: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/7.jpg)
7
Clocks – Differences to combination
No final answer for 2000
Rep
ro
No RINEX clock files
Only 2 ACsIGF:25 ± 4 ps
Ope
ratio
nal
Good repro clock quality (official: more ACs, including 30s)
3 ACs
6 ACs (3x30sec)
![Page 8: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/8.jpg)
8
Orbit – ScaleR
epro
IGF: +0.17 ± 6 ppbIGF: - 0.18 ± 7 ppb
Ope
ratio
nal
ACs have different scale.
Causing a diff of 0.35 ppb btw 2000 and 2007 in operational time series
Stability per AC and biases are similar to operational solution
![Page 9: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/9.jpg)
9
Orbit – X-Transformation
Consistency among ACs in 2000 is now comparable to 2007
Rep
roO
pera
tiona
l
![Page 10: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/10.jpg)
10
Orbit – Y-TransformationR
epro
Ope
ratio
nal
![Page 11: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/11.jpg)
11
Orbit – Z-Transformation
2000: ACs have smaller scatter, but biases are still there
Rep
roO
pera
tiona
l
![Page 12: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/12.jpg)
12
Orbit – X-Rotation
ACs have smaller scatter, but still biases. Problem at SI1 (not in SNX combi).
Rep
roO
pera
tiona
l
Large biases at PD1 caused by present inconsistency to SNX
![Page 13: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/13.jpg)
13
Orbit – Y-Rotation R
epro
Ope
ratio
nal
![Page 14: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/14.jpg)
14
Orbit – Z-RotationR
epro
Ope
ratio
nal
2000: ACs have smaller scatter, but still biases. Problem at ES1.
![Page 15: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/15.jpg)
15
X-PoleR
epro
Ope
ratio
nal
ACs have better quality.But not as good as in 2007 (RF!)
Good repeatability at ACs (PD1!)IGF & IRF small scatter, no bias
![Page 16: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/16.jpg)
16
X-PoleR
epro
Ope
ratio
nal
ACs have better quality.But not as good as in 2007 (RF!)
Good repeatability at ACs (PD1!)IGF & IRF small scatter, no bias
![Page 17: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/17.jpg)
17
X-PoleR
epro
Ope
ratio
nal
ACs have better quality.But not as good as in 2007 (RF!)
Good repeatability at ACs (PD1!)IGF & IRF small scatter, no bias
![Page 18: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/18.jpg)
18
Y-PoleR
epro
Ope
ratio
nal
![Page 19: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/19.jpg)
19
Rep
roO
pera
tiona
l
LOD
ACs have better quality.But not as good as in 2007 (RF!)
Good repeatability at ACs (better ES1)IGF & IRF small scatter, no bias
![Page 20: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/20.jpg)
20
Rep
roO
pera
tiona
l
LOD
ACs have better quality.But not as good as in 2007 (RF!)
Good repeatability at ACs (better ES1)IGF & IRF small scatter, no bias
![Page 21: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/21.jpg)
21
Rep
roO
pera
tiona
l
LOD
ACs have better quality.But not as good as in 2007 (RF!)
Good repeatability at ACs (better ES1)IGF & IRF small scatter, no bias
![Page 22: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/22.jpg)
22
X-Pole rateR
epro
Ope
ratio
nal
![Page 23: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/23.jpg)
23
Y-Pole rateR
epro
Ope
ratio
nal
![Page 24: Gerd Gendt and Thomas Nischan - Geodesy · 2017-05-16 · No final answer for 2000 Repro No RINEX clock files ... Good repro clock quality (official: more ACs, including 30s) 3 ACs](https://reader034.vdocuments.us/reader034/viewer/2022050521/5fa520d37dac0a0a9e02b4fe/html5/thumbnails/24.jpg)
24
SummaryReprocessing evaluation
2007: Repro has same quality as latest operational products
2000: Repro quality is better than for the old operational products (better, consist. S/W & models result in more consistent submissions)
Problem for clocks (still not enough submissions; especially for 30s)
More ACs shall join the reprocessing; esp. for clocks
For the clock solutions the unique 4-character ID (RINEX file name) shall be used.