Transcript
Page 1: GEIEC Devices C-2000™ 4-Pole Contactors · 2015. 7. 15. · CL01A400T* CL02A400T* CL03A400M* CL04A400M* CL05A400M* CL07A400M* — CL09A400M* List Price, GO-10C2 $109.00 143.00 176.00

|U U

GEIEC Devices

C-2000™ 4-Pole ContactorsNonreversing Only

To complete the contactor catalog number, replace theappropriate digit from the Coil Selection table.

t, **, or 11 in the catalog number with the

7.5-60 Hp (460 V) AC Only

* Coil SelectionFor catalog numbers withprefixes CL01, CL02, CL03,CL04, CL05, CL07, CL08and CL09.

AC-3Max.

Amps@460V

13.8

17.5

25

32

42

62

68

80

Single-Phase

1 1 5 V

0.751

2

2

3

5

5

7.5

230V

2

3

3

5

7.5

10

10

1 5

Three-Phase

200V

3

5

7.5

10

10

20

20

25

230V

3

5

7.5

10

15

20

25

30

460V

7.5

10

15

20

30

40

50

60

575V

10

15

20

25

•30

50

60

75

Aux.Contacts

(A600,Q600)

None

None

None

None

None

None

None

None

CoilVolts

AC

AC

AC

AC

AC

AC

AC

AC

4 Normally Open

Catalog No. ffl

CL01A400T*

CL02A400T*

CL03A400M*

CL04A400M*

CL05A400M*

CL07A400M*

CL09A400M*

List Price,GO-10C2

$109.00

143.00

176.00

225.00

340.00

425.00

475.00

2 Normally Open2 Normally Closed

Catalog No.

CL01ABOOT*

CL02ABOOT*

CL03ABOOM*

CL04ABOOM*

CL05ABOOM *

CL07ABOOM*

CL08ABOOM*

-

List Price,GO-10C2

$109.00

143.00

176.00

225.00

340.00

425.00

447.00

-

AC Voltage

60 Hz

24

48

120

208

277

240

480

600

50 Hz

24

42

1 1 0

220/230

380/400

415

500

*CoilSuffix

1

F

J

L

N

S

U

wY

Note: Additional coils available,see page 3-16.

125-500 Hp (460 V) AC/DCAC-3Max.

Amps@460V

156

192

302

398

398

480

480

602

Three-Phase

200V

50

60

100

125

125

150

150

200

230V

60

75

100

150

150

200

200

250

460V

125

150

250

300

300

400

400

500

575V

125

150

300

400

400

500

500

600

Aux.Contacts

(A600,Q600)

1NO-1NC®

1 NO-1 NC ffl

1 NO-1 NC ffl

1NO-1NC©

1 NO-1 NC ffl

1 NO-1 NC ffl

1NO-1NC®

1 NO-1 NC ffl

CoilVolts

AC/DC

AC/DC

AC/DC

AC/DC

AC/DC

AC/DC

AC/DC

AC/DC

4 Normally Open

Catalog No. ffl

CK08BE41 1 1

CK09BE411t

CK95BE411t

CK10CE41lt

CK10BE41lt

CK11CE41 l t

CK11BE41 l t

CK12BE411t

List Price,GO-10C2

$1,375.00

1,750.00

2,250.00

3,520.00

3,872.00

5,250.00

5,775.00

6,900.00

tCoil SelectionFor catalog numbers withprefixes CK08, CK09, CK95,CK10, CK11,andCK12.

AC60/50 Hz

24-28

42-48

1 1 0 - 1 2 7

220-250

380-415

440-500

DC

24-28

42-48

110-127

220-250

380-415

440-500

tCoilSuffix

D

F

J

N

U

Y

® Auxiliary contact shipped unassembled.

7.5-60 Hp (460V), DC Only or AC/DCAC-3Max.

Amps@460V

13.8

17.5

25

32

48

62

68

80

Single Phase— HP60 Hz

115V

0.75

1

2

2

3

5

5

7.5

230V

2

3

3

5

7.5

10

10

1 5

Three Phase— HP 60Hz

200V

3

5

7.5

10

10

20

20

25

230V

3

5

7.5

10

1 5

20

25

30

460V

7.5

10

15

20

30

40

50

60

575V

10

1 5

20

25

30

50

60

75

kW50Hz

380/415V

5.5

7.5

12.0

16.0

18.5

30.0

37.0

45.0

Aux.Contacts

(A600,Q600)

None

None

None

None

None

None

None

None

CoilVolts

DC

DC

DC

DC

AC/DC

AC/DC

AC/DC

AC/DC

4 Poles Normally Open

Catalog No.

CL01D400T**

CL02D400T**

CL03D400M**

CL04D400M**

CL05E400Mtt

CL07E400Mtt

CL09E400Mtt

List Price,GO-10C2

$132.00

166.00

232.00

263.00

405.00

484.00

544.00

2 Poles Normally Open,2 Poles Normally Closed

Catalog No.

CL01DBOOT**

CL02DBOOT**

CL03DBOOM"

CL04DBOOM**

CLOSEBOOMtt

CL07EBOOMtf

CLOBEBOOMtt

' -

List Price,GO-10C2

$132.00

166.00

232.00

263.00

405.00

484.00

516.00

-

Coil Selection TablesForCLOl— CL04(**)

DC Volts

122448

120/125250

CoilSuffix

BDGKT

ForCL05-CL09(tt)DC/ACVoits

24-2842-48

110-127220-250

CoilSuffix

DFJN

Note: Additional coilsavailable, see page 3-16.

Prices and data subject to change without notice 1999 Issue 3-7

Page 2: GEIEC Devices C-2000™ 4-Pole Contactors · 2015. 7. 15. · CL01A400T* CL02A400T* CL03A400M* CL04A400M* CL05A400M* CL07A400M* — CL09A400M* List Price, GO-10C2 $109.00 143.00 176.00

LJ-

GEIEC Devices

General Specifications for C-2000™ Contactors & Starters

Standards And Listings EC 947-1EC 947-4EC 158-1CENELECHD419NFC.63-110

BS 5424BS775CEI 1 7-3/252ASE 1 025UL508

CSAC.22.2/14EN 50005UNE20109VDE 0660/1 02CE Mark

ZH1/457 (Positive Guided Contacts)

Pending StandardsAnd Listings

SEMKO, NEMKO, DEMKO, Lloyds Register

Ambient TemperatureOperatingStorage .

-13° to +131°F/-25°to +55°C-58° to +176°F/-50°to +80°C

Altitude DeratingUp to 10,000 ft. ;

(3,000 m)10,000 to 13,200 ft.(3,000 to 4,000 m)13,200 to 16,000 ft.(4,000 to 5,000 m)

Nominal Values

90% rated current

80% rated current

Rated Insulation Voltage 600 Vac, U, = 1000V (per EC 947)

Mounting Position3-Pole and 4-PoleCL Contactors (5-75 Hp)

To maintain operating integrity, the contactor must be mounted in one of the positions shown below:

i) o o o]QDOQ[

o o oIo

oo

!dHBSF!F!

ooo J

o o oDDDDDD

DDDDQD000

[ ooo

HHD 1=1a 1=1a en

Ooo

3-Pole and 4-PoleCK Contactors(100-500 Hp)

The contactor must be installed vertically or tilted a maximum of 30° from vertical, as shown below:

3-36 1999 Issue Data subject to change without notice


Top Related