FireProtectionProducts
Fivalco Inc.Trusted For Quality For Over 20 Years
-
8/2/2019 Fpp Catalogue 2012
2/38
Fivalco General Information
Fivalco is a US company in our 20 th year of manufacturing Fire Protection Valves of uncompromising quality for our discerningcustomers.
All our products are FM or UL approved and most carry both UL and FM listings / approvals.
The latest edition of the NFPA code stated products shall be listed or approved, without reference to either UL or FMalthough it is common practice for consultants to specify both a UL listing and a Factory Mutual approval.
UL listed means that the product has been tested, has passed all the stringent tests mandated by UL and is listed in the ULcatalogue of Fire Protection Equipment
FM approved means that the product has passed all severe tests mandated by Factory Mutual and is approved by FM for use inbuilding structures insured by Factory Mutual Insurance.
We, and all other manufacturers of similar products are subject to identical factory and product audit approvals and tests withoutcompromise as the same approval and test criteria are applied to all producers of such products.
All butter y and gate valves are pressure tested for approval at 4 times the working pressure depending on valve size, and allvalves must pass a cycling test of 1000 open/shut operations without failure of any part or component.
We take great care to make our products both attractive and functional and it is essential that our customers and end users dothe same in order to maintain product integrity and proper function.
We draw your attention to minimum practices for handling and installation of our valves,at the end of this catalogue.
We are not content with making valves purely to meet mandatory speci cations and have added quality and other features tostand out above the crowd.
All gate valves have Stainless Steel Stems for better corrosion resistance-our competitors use common brass.All gate valves are painted true Fire Engine Red-RAL 3000-no on site painting needed.
All materials for Butter y Valves are equal to or superior to our competitors
The quality goes in before our name goes on All written material in this catalogue is copyrighted and may not be produced in part or in whole without express writtenpermission. Violators will be prosecuted.
Fivalco, Fireriser, Fireriser HP and Fire y are our registered Trade Marks.
Use of the trade marks without written permission is illegal and all violators will be prosecuted to the full extent of the law.
Fire Protection Products
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
-
8/2/2019 Fpp Catalogue 2012
3/38
Fivalco Product Index Approved and Listed Valves
FIRERISER
GATE VALVES3299-300-F DUCTILE IRON RESILIENT OS&Y GATE VALVE FLANGED END ................................................................1 3288-300-F DUCTILE IRON RESILIENT NRS GATE VALVES FLANGED END ..............................................................2 IP888 VERTICAL INDICATOR POST ................................................................................................................................3 WP999 WALLTYPE INDICATORPOST4
INDICATOR POST ADJUSTMENT ....................................................................................................................................5
CHECK VALVES
FIRE CHECK DCG GROOVED END ................................................................................................................................6/7
FIRERISER BUTTERFLY VALVES
FIRERISER HPW WAFER BUTTERFLY VALVE 300PSI ..............................................................................................8 FIRERISER HPG GROOVED BUTTERFLY VALVE 300PSI .........................................................................................9 FIRERISER HPG T GROOVED/TAPPED BUTTERFLY VALVE 300PSI ......................................................................10 FIRERISER DW WAFER BUTTERFLY VALVE 175PSI ................................................................................................11
FIREFLY DG BUTTERFLY VALVE 175PSI .......................................................................................................................12
FIREFLY BG BRONZE BUTTERFLY VALVE 175PSI .......................................................................................................13 FIREFLY BT BRONZE BUTTERFLY VALVE 175PSI .......................................................................................................14 WAFER BUTTERFLY VALVE.............................................................................................................................................15 GROOVED BUTTERFLY VALVE ........................................................................................................................................16 INSTALLATION GUIDE .......................................................................................................................................17/18/19/20 BUTTERFLY VALVE PACKING ........................................................................................................................................21
FLEXIBLE SPRINKLER CONNECTOR
QUICKONNECT FLEXIBLE SPRINKLER CONNECTOR .........................................................................................22/23FIRE HOSE VALVES
FORGED BRASS FIRE HOSE VALVE 300PSI ................................................................................................................24
UL LISTED TRIM VALVESBRASS BALL VALVE PN20/300 PSI ................................................................................................................................25 STRAIGHT GLOBE VALVE PN20/300 PSI .......................................................................................................................26 ANGLE GLOBE VALVE PN20/300 PSI .............................................................................................................................27 AIR VENT VALVES
AUTOMATIC AIR VENT VALVE .......................................................................................................................................28
BREECHING INLET
TWO WAY BREECHING INLET ........................................................................................................................................29 FOUR WAY BREECHING INLET .......................................................................................................................................30 LANDING VALVES
LANDING VALVES 2-1/2'' BS FLANGED .........................................................................................................................31 LANDING VALVES 2-1/2'' BS THREADED .......................................................................................................................32
FIVALCO INC LIMITED WARRANTY .............................................................................................................................33
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
-
8/2/2019 Fpp Catalogue 2012
4/38
Resilient Seated-300PSI-OS&Y Type-Flanged End Fig No.: 3299-300-F
Valve Standard: Conforms to AWWA C515 / BS5163
Working pressure: 21 BARS/300PSI.Fusion Bonded Epoxy Coated Interior and Exterior RAL3002Flanged Ends: ANSI B16.1 Class125/150/250, EN1092-2 PN10/PN16,BS10 Table EStainless Steel Stem
Materials List:
Name MaterialBody Ductile Iron ASTM A536 65-45-12
Wedge Ductile Iron ASTM A536 65-45-12 +EPDMWedge Nut Stainless Steel AISI 304
Stem Stainless Steel AISI304/302Bonnet Ductile Iron ASTM A536 65-45-12Gasket EPDMPacking Graphite
Stem Nut Bronze ASTM B62Handwheel Ductile Iron ASTM A536 65-45-12
Dimensions (In/mm):Size Size 2-2/1/65 3/80 4/100 5/125 6/150 8/200 10/250 12/300
L 7.50/191 8.00/203 9.00/229 10.0/254 10.50/267 11.50/292 13.00/330 14.00/356
H 16.46/418 19.21/488 21.18/538 25.75/654 29.13/740 36.81/935 44.33/1126 51.81/1316
D 7.20/183 9.96/253 9.96/253 12.05/306 12.05/306 13.98/355 17.52/445 17.52/445
Notes:
1. Design and dimensions conform to AWWA C515.
2. Flanged to ANSI B16.1, 125#. other flange types available.
3. Fusion bonded epoxy coated interior and exterior.
4. Valve is rated at 300PSI for Fire Protection Service.
5. Design and materials are subject to change without notice.
Fivalco
Highriser Gate Valve
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
-
8/2/2019 Fpp Catalogue 2012
5/38
Resilient Seated-300PSI-NRS Type-Flanged End Fig. No.: 3288-300-F
Valve Standard:Conforms to AWWA C515 / BS5163
Working pressure: 21 BARS/300PSI.Fusion Bonded Epoxy Coated Interior and Exterior RAL3002
Flanged Ends: ANSI B16.1 Class125/150/250, EN1092-2 PN10/PN16/BS10 Table E
Stainless Steel Stem
Materials List:Name MaterialBody Ductile Iron ASTM A536 65-45-12
Wedge Disc Ductile Iron ASTM A536 65-45-12 +EPDMDisc Nut Bronze ASTM B62
Stem Stainless Steel AISI 304/302Gasket EPDMBonnet Ductile Iron ASTM A536 65-45-12
Thrust Collar Bronze ASTM B62Gland Ductile Iron ASTM A536 65-45-12
Wrench Nut Ductile Iron ASTM A536 65-45-12Post Plate Ductile Iron ASTM A536 65-45-12
Dimensions (In/mm):Size 2-1/2/65 3/80 4/100 5/125 6/150 8/200 10/250 12/300
L 7.50/191 8.00/203 9.00/229 10.00/254 10.50/267 11.50/292 13.00/330 14.00/356
H 11.61/295 12.72/323 13.46/342 16.06/408 17.32/440 21.14/537 25.20/640 28.46/723
D 12.01/305 12.01/305 12.01/305 12.01/305 12.01/305 12.01/305 12.01/305 12.01/305
Notes:
1. Stainless steel stem.
2. Design and dimensions conform to AWWA C515.
3. Flanged to ANSI B16.1, 125#. other flange types available.
4. Fusion bonded epoxy coated interior and exterior.
5. Valve is rated at 300PSI for Fire Protection Service.
6. Design and materials are subject to change without notice.
7. All valves Provided with 2"(50mm) operating Nut.
Fivalco
Highriser Gate Valve
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
-
8/2/2019 Fpp Catalogue 2012
6/38
Fig. No: IP888
Materials List:No Qty Name Material
1 1 Locking Wrench ASTM A126B
2 1 Operating Nut ASTM B62
3 2 Hex Nut Screw ASTM A105
4 2 Hex Nut ASTM A105
5 1 Snap Ring AISI 066
6 1 Target Carrier Nut ASTM B62
7 4 Target ASTM B108
8 4 Hex Cap Nut ASTM A1059 2 Window Glass LEXAN-UN
10 2 Window Glass Gasket PTFE
11 4 Hex Cap Screw ASTM A105
12 4 Hex Nut ASTM A105
13 1 Body ASTM A536
14 6 Hex Cap Screw ASTM A105
15 6 Hex Nut ASTM A105
16 1 Base Flange ASTM A126B
17 4 Hex Cap Screw ASTM A105
18 4 Hex Nut ASTM A105
19 1 Crane Coupling ASTM A536
20 1 Cotter Pin AISI 304
21 1 Stand Pipe ASTM A53
22 1 Stem AISI A1045
23 1 Plug AISI 304
24 1 Cover ASTM A126B
25 1 Locking Nose ASTM 307 B
Field Adjustment:
1. Remove the top section from the top of the Indicator Post assembly.
2. Cut the required length off the bottom of the Standpipe for the Ground Line to match up with Standpipe Ground Line
mark.
3. Set the "OPEN" and "SHUT" targets for the appropriate valve size.
4. Reattach the Top Section to the top of the Indicator Post assembly.
5. Design and dimensions are subject to change without notice.
Fivalco
Fireriser Indicator Post
Long Post
-3-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
-
8/2/2019 Fpp Catalogue 2012
7/38
Fig. No: WP999
Materials List:
Field Adjustment: 1. Remove the top section from the top of the Indicator Post assembly.
2. Set the "OPEN" and "SHUT" targets for the appropriate valve size.
3. Reattach the Top Section to the top of the Indicator Post assembly.
4. Design and dimensions are subject to change without notice.
No. Component Qty Material
1 Lifting Eyey Bolt 1 ASTM A105
2 Hex Nut 1 ASTM A105
3 Washer 1 ASTM A105
4 Hand Wheel 1 ASTM A536
5 Operating Nut 1 ASTM B62
6 Hex Cap Screw 2 ASTM A105
7 Hex Nut 2 ASTM A105
8 Snap Ring 1 AISI 066
9 Target Carrier Nut 1 ASTM B62
10 Target 4 ASTM B108
11 Hex Cap Screw 4 ASTM A105
12 Window Glass 2 LEXAN-UN
13 Window Glass Gasket 2 PTFE
14 Hex Cap Screw 4 ASTM A105
15 Hex Nut 4 ASTM A105
16 Body 1 ASTM A536
17 Stand Pipe 1 ASTM A53
18 Stem 1 AISI 1045
19 Cotter Pin 1 AISI 304
20 Crane Coupling 1 ASTM A536
21 Plug 1 AISI 304
22 Cover 1 ASTM A126B
23 Locking Nose 1 ASTM 307 B
Fivalco
Fireriser Indicator Post
Wall Type
-4-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
-
8/2/2019 Fpp Catalogue 2012
8/38
Fireriser
Indicator Post Adjustment
InstallationNOTE: Ensure that the Non-rising Stem Gate Valve is in thefully open position before installing the Ver-tical Indicator Post.
1.) Disassemble the Indicator PostTake off the Locking Wrench(11). slide odd the Top Section(20)together with the Operating Nut(19) and the square Stem(9)as well as the Crane Coupling(3)and ensure that all other accessories attached from the end of the Body(10) byloosening two Hex Cap screws(24) and Square Nut(23),
slide off the Body(10) from the Standpipe(8) by looseningtwo Hex Cap Screws and Hex Nut, Loosen the two Hex CapScrews and Hex Nut, Slide off the Standpipe(8) from the BaseFlange(5).
2.) Install the Base Flange and StandpipeAttach the Base Flange(5) together with the Standpipe(8) tothe Post Flange of the Non-rising Stem Gate Valve using thefour Cap Screws(1) and Hex Nut(2).
3.) Adjust the Grade Line MarkPull in and lower the Body(10) over the Standpipe(8) until the
Ground Line Mark on the Body(10) is the same height as groundlevel. TIGHTEN THE Two Hex Cap Screws and Hex Nut.
4.) Adjust the Square StemLower the Stem(9) into Body (10) Standpipe(8) such that theCrane Coupling(13) fits over the Operating nut of the Non-rising Stem Gate Valve Ensure that the Stem(9) engages theOperating Nut(19) a minimum of 2 inches but no more than4,5 inches, To check for correct engage-ment, the end of stemshould be from 2 to 4, 5 inches below the top of the Body(10).
5.) Adjust the TargetsRemove the Target Carrier Assembly(12+13+14) frominside the Body(10) by rotating the Operating Nut(19)counterclockwise. The Open Target(16) and Shut Target(notshown) are adjusted up or down on the Target Carrier Assembly(12+13+14) by pull-ing the middle section of theTarget(Open and Shut) a small distance away from the TargetCarrier As-sembly(12+13+14) and sliding the Target(Open andShut) up or down as desired.
If the Non-Rising Stem Gate Valve is opened left: move thetwo Open Targets(16)to the very top of the TargetCarrier Assembly(12+13+14). Locate the two Shut Targets(notshown) according to the Non-rising Stem Gate Valvesize(stem) turning distance. If the Non-rising Stem Gate Valveis opened right: move the two Shut Targets(not shown) to thevery top of the Target Carrier Assembly(12+13+14). Locatethe two Open Targets(16) according to the Non-ris-ing StemGate Valve size(stem) turning distance.
6.) Final Assembly and TestInsert the Target Carrier Assembly(12+13+14) back into theTop Section (20) by rotating the Operating Nut(19) clockwise,Rotate until the Open Target(16) is centered in the window of the window of the Body(10) which corresponds with the Nut-rising Stem Gate Valve being in the open position. Lower theTop Sec-tion(20) with Target Carrier Assembly(12+13+14)onto the Body(10), assuring that the Stem(9)Engages with the Operating Nut(19) at least 2 inches butnot more than 4.5inches. Secure the Top Sec-tion(20) to theBody(10) by tightening the Cap Screw(24) and Square Nut(23)Close the Non-ris-ing Stem Gate Valve and make sure thatthe Shut Target(not shown) is properly centered in the windowof the Body(10) and adjust as necessary.
MaintenanceOil the bearing in the Top Section(20) at least once per year by adding several drops of oil in the hole located on the top of the Operating Nut(19).
-5-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
9/38
Highriser Grooved Check Valve
SPECIFICATIONSWorking Pressure : 300 PSI (21 Bars)Max. Test Pressure: 500 PSI (34.5 Bars)Max. Working Temp : 250 ( 120 )
Primary Materials:
Component Material
Body Ductile iron conforming toASTMA-536epoxy coated
Color Red or black (optional)
Clapper
2"-5 " type 304 or 302 stainlessSteel to ASTMA-167
6"-8" ductile iron conforming toASTMA-536, grade 65-45-12
Clapper FacingGrade E EPDM
-40 to 230 ( -40 to 110 )Service Temperature range
Seat RingType 304 stainless steel toASTMA-123 ASTMA-213
ASTMA-312 or ASTMA-269
Spring Type 302 stainless steel toASTMA-313
Hinge Pin Type 304 or 302 stainless steel to
ASTMA-580Hinge PinBushings Sintered bronze to ASTMB-438
Flow Date-Friction Los (Ft. Pipe)Valves Pipe C=100 C=120
Size OD Sch.10 Sch.30 Sch.40 Sch.10 Sch.30
Sch.40
In/mm In/mm Ft/m Ft/m Ft/m Ft/m Ft/m Ft/m
2 2.375 10 -- 8 14 -- 11
50 60.3 3.0 --- 2.4 4.3 ---- 3.4
2-1/2 2.875 14 -- 10 20 -- 15
65 73.0 4.3 --- 3.0 6.1 --- 4.6
3 3.500 17 -- 12 23 -- 17
80 88.9 5.2 --- 3.7 7.0 -- 5.5
4 4.500 17 -- 13 23 -- 18
100 114.3 5.2 --- 4.0 7.0 -- 5.5
5 5.562 14 -- 11 20 -- 15
125 141.3 4.3 --- 3.4 6.1 --- 4.66 6.625 23 - - 19 33 -- 26
150 168.3 7.0 --- 5.8 10.1 --- 7.9
8 8.625 35 32 30 50 43 43
200 21.9 10.7 9.6 9.1 15.2 13.1 13.7
Fig.No.:DCG
-6-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
10/38
Highriser Grooved Check ValveGrooved Check Valves,UL.ULC Listed/FM ApprovedGrooved End, Size: 2-1/2", 3", 4", 6" and 8"
WORKING PRESSURE 300PSI/21BARSThe Check Valve is a compact, cost effective valve offering lowpressure-drop, non-slam performance the Check valve assemblyis lighter and fast to install, and costs less than anged and wafer valve assemblies. In the fully-open position the clapper is heldtightly against the valve body, out of the flow stream, to providemaximum ow area and prevention of clapper utter. The clapper design produces quick, non-slam closure before ow reversal canoccur, while meeting FM requirements for an anti-water hammer valve rating. Each valve is hydrostatically tested for leak tightnessto 500 PSI. The clapper-seat design permits leak free sealing of back pressures in service conditions ranging from 300 PSI to aslow as 5 P I
Fig.No:DCG
-7-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
11/38
SPECIFICATIONSWorking Pressure: 300 PSI (21Bars)Max.Test Pressure: 600 PSI (42.8 Bars)Max.Working Temp: 250 (120)Factory installed UL, listed double Tamper SwitchesValve Approved For Indoor and Outdoor Use
Primary Materials
Component MaterialBody ASTM A-536 Nylon-11 Coated
Disc ASTM B-536 EPDM Encapsulated
Upper&Lower Stems AISI 420-SS
Worn Gear Shaft AISI 410-SS
Housing ASTM A-536
Hand Wheel ASTM A-536
Flag Indicator ASTM A-536
Shear Pin ASTM A-510
Segment Gear ASTM B-148 or B-548
HousingGasket EPDM Grade"E"
O-Rings (All) EPDM Grade"E"
Dimensions (mm/in):
Size In/mm A B C D E F G H
2-1/2/65 5.39(136) 3.43(87) 1.81(46) 5.89(149.4) 6.54(166) 5.31(135) 5.04(128) 0.32(8.2)
3/80 5.63(143) 3.66(93) 1.81(46) 6.62(168.2) 6.81 (173) 5.31(135) 5.04(128) 0.57(4.9)
4/100 6.14(156) 4.29(107) 2.06(52) 7. 89(200.2) 7.32(186) 5.31(135) 5.04(128) 0.89(22.7)
6/150 7.4(188) 5.67(144) 2.20(56) 10.6(269.8) 8.58(218) 8.66(193) 8.66(222) 1.79(44.4)
8/200 8.7(222) 6.54(166) 2.28(58) 13.0(330.2) 9.92 (252) 8.66(193) 8.66(222) 2.72(69.1)
Fireriser Butter y Valve Wafer Type Butter y Balves, UL, ULC Listed/FM Approved Wafer Type, Sizes: 2-1/2", 3", 4", 6" and 8". Fig.No:HPW
-8-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
12/38
Fireriser Butter y Valve
Grooved Butter y Valves, UL ULC Listed/FM Approved
SpecifcationsWorking Pressure: 300 PSI (21Bars)Max.Test Pressure: 600 PSI (42.8 Bars)Max.Working Temp: 250 (120)Factory installed UL, listed double Tamper SwitchesValve Approved For Indoor and Outdoor Use
Primary Materials:
Component MaterialBody ASTM A-536 Nylon-11 Coated
Disc ASTM B-536 EPDM Encapsulated
Upper&Lower Stems AISI 420-SS
Worn Gear Shaft AISI 410-SS
Housing ASTM A-536
Hand Wheel ASTM A-536
Flag indicator ASTM A-536
Shear Pin ASTM A-510
Segment Gear EPDM Grade"E " ASTM B-148 or B-584
Housing Gasket EPDM Grade E
O-Rings (All) EPDM Grade E
Dimensions(mm/inch):
Size A B C D E F G H
2-1/2 4.1(106) 3.3(85) 3.80(96.4) 2.8(73.0) 5.31(136) 5.04(128) 5.04(128)
3 4.4(112) 3.6(92) 3.80(96.4) 3.50(83.9) 5.99 (142) 5.04(128) 5.04(128)4 5.7(145) 4.34(108) 4.54(115.4) 4. 50(114.3) 6.89(173) 5.04(128) 5.04(128)
6 7.1(180) 5.7(146) 5.21(132.4) 6.6(168.3) 8.23(209) 8.66(220) 8.66(220). 0.28(7.10)
8 8.0(204) 6.7(170) 5.80(147.4) 8.63(219.1) 9.21 (234) 8.66(220) 8.66(220). 0.9(24.0)
10 8.98(224) 7.88(200) 6.26(199) 10.75(273) 10.16(256) 9.65(245) 11.23(289)
12 10.52(267) 9.14(232) 6.50(65.1) 11.10(297) 9.65(245) 9.65(245) 11.23(289)
Fig.No.:HPG
-9-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
13/38
Fireriser Butter y Valve
Grooved Butterfly Valves, UL ULC Listed/FM Approved Two Tapped Outlets
Primary Materials
Component MaterialBody ASTM A-536 Nylon-11 Coated
Disc ASTM B-536 EPDM Encapsulated
Upper&Lower Stems AISI 420-SS
Worn Gear Shaft AISI 410-SS
Housing ASTM A-536
Hand Wheel ASTM A-536
Flag indicator ASTM A-536
Shear Pin ASTM A-510
Segment Gear ASTM B-148
Housing Gasket EPDM Grade"E"
O-Rings (All) EPDM Grade"E"
Dimensions (mm/in)
Size In/mm A B C D E F G H N M21/2/65 105 127 135 73.0 135 128 30 13 4--1/2-14NPT
3/80 112 127 135 88.9 142 128 30 13 4--1/2-14NPT
4/100 145 127 135 114.3 175 128 30 13 4--1/2-14NPT
6/150 179 143.5 193 168.3 209 220 6.8 40.4 15 4--3/4-14NPT
8/200 204 152.4 193 219.1 234 220 24.2 40.4 15 4--3/4-14NPT
SpecifcationsWorking Pressure: 300 PSI (21 Bars)Max.Test Pressure: 600 PSI (42.8 Bars)Max.Working Temp: 250 (120)Factory installed UL listed double Tamper SwitchesValve Approved For Indoor and Outdoor Use
Fig.No.:HPGT
-10-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
14/38
Primary Materials:
Component MaterialBody ASTM A-536 EMPE Encapsulated
Disc ASTM B-548 or B-148
Upper&Lower Stems
AISI 420-SS
Worn Gear Shaft AISI 410-SS
Housing ASTM A-536
Hand Wheel ASTM A-536
Flag indicator ASTM A-536
Shear Pin ASTM A-510
Segment Gear ASTM B-148
Housing Gasket EPDM Grade E
O-Rings (All) EPDM Grade E
Universal wafer Type Butter y Valve Suitable for Connect-ing to ANSI B 16 Class 125, ISO 2084/Din 2501 PN 16 & BS4504 PN 16 Flanges
Sp eci f cationsWorking Pressure: 175 PSI (12.5 Bars)Max.Test Pressure: 350 PSI (25.0 Bars)Max.Working Temp: 250 (120)
Factory installed UL, listed double Tamper SwitchesValve Approved For Indoor and Outdoor Use
Dimensions(mm/inch):
Size A B C D E F G H2-1/2/65 4.1(106) 3.3(85) 1.8(46) 3.6(92) 5.3(135) 5.3(135) 4.9(125) 0.4(9.5)
3/80 4.4(112) 3.6(92) 1.8(46) 4.2(107) 5.6 (142) 5.3(135) 4.9(125 0.6(16)
4/100 5.7(145) 4.34(108) 2.0(52) 5. 0(128) 6.9(175) 5.3(135) 4.9(125. 1.0(25)
6/150 7.1(180) 5.7(146) 2.2(56) 7. 1(181) 8.3(210) 7.6(193) 8.9(225) 1.8(45.3)
8/200 8.0(204) 6.7(170) 2.4(60) 9.2(234) 9.1 (232) 7.6(193) 8.9(225). 2.7(68.5)
Fireriser Butter y Valve Water Type Butter y Valves,UL,ULC Listed/FM ApprovedDW Water Type,Size: 2-1/2", 3", 4", 6", 8" Fig.No.:DW
-11-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
15/38
Fireriser Grooved Butter y Valve
UL, ULC Listed/ FM Approved
Speci f cationsWorking Pressure: 175 PSI(12.5 Bars)Max. Test Pressure: 350 PSI(25.0 Bars)Max. Working Temp.: 250 (120)Factory Installed UL Listed Double Tamper SwitchesValve Approved For Indoor and Outdoor Use
Primary Materials
Component MaterialBody ASTM A-536 Nylon-11 Coated
Disc ASTM B-536 EPDM Encapsulated
Upper&Lower Stems AISI 420-SS
Worn Gear Shaft AISI 410-SS
Housing ASTM A-536
Hand Wheel ASTM A-536
Flag indicator ASTM A-536
Shear Pin ASTM A-510
Segment Gear ASTM B-148
Housing Gasket EPDM Grade E
O-Rings (All) EPDM Grade E
Dimensions(mm/inch)
Size A B C D E F G H2-1/2 4.1(106) 3.3(85) 3.7(94.6) 2.9(73.0) 5.3(135) 5.3(135) 4.9(125)
3 4.4(112) 3.6(92) 3.8(96.4) 3.5(83.9) 5.6 (142) 5.3(135) 4.9(125
4 5.7(145) 4.34(108) 4.5(114.4) 4. 6(116.2) 6.9(175) 5.3(135) 4.9(125.
6 7.1(180) 5.7(146) 5.3(133.4) 6.6168.3) 8.3(210) 7.6(193) 8.9(225). 0.28(7.10)
8 8.0(204) 6.7(170) 5.8(147.7) 8.6(219.1) 9.1 (232) 7.6(193) 8.9(225). 0.9(24.0)
Fig.No.:DG
-12-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
16/38
Dimensions
Size in/mm A B C D E F G2/50 4.56(114) 2.41(60.3) 2.29(57.15) 0.64(16) 0.32(8) 1.96(49) 3.62(90.5)
2-1/2/65 4.56(114) 3.0(75) 2.75(69.1) 0.64(16) 0.32(8) 2.18(54.5) 3.82(95.5)
Patent Pending.
Speci f cationsWorking Pressure: 175 PSI (12.5 Bars)Max.Test Pressure: 350 PSI (25.0 Bars)Max.Working Temp. : 250 (120)Factory Installed UL Listed Double Tamper SwitchesValve Approved For Indoor and Outdoor Use
Primary Materials:
Component MaterialBody ASTM B-505
Disc ASTM B-548 EPDM Encapsulated
Upper Stem ASTM A-564 Type XM12
Lower Stem ASTM A-564 Type XM12
Gear HousingCover ASTM A-619
Hand Wheel ASTM A-619
Flag Indicator ASTM B-16
Yoke Mechanism ASTM A-283
Stem Bushing ASTM B-16
Conduit Connector ASTM A-307
O-Rings EPDM Grade"E"
Cover Gasket NBR9
Fireriser Butter y ValveBronze Butter y Valve, UL, ULC Listed/FM ApprovedBG Grooved End, Size: 2" and 2-1/2" Fig.No.:BG
-13-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
17/38
Fireriser Butter y ValveBronze Butter y Valves,UL,ULC Listed/FM ApprovedBT Size: 1", 1-1/4", 1-1/2", 2" and 2-1/2"
Dimensions:Size A B C D E F G
1/25 1.75(43.7) 1.56(39.7) 2.16(54) 2.08(52) 1.48(52) 43 34.)
1-1/4"/32 2.16(54) 196(47) 2.68(67) 2.24(56) 1.64(41) 47 471-1/2/40 2.4(60) 2.24(70) 2.92(73) 2.36(90) 2.45(61.3) 50 48.6
2/50 2.8(70) 2.8(70) 3.3(82.4) 2.56(54) 1.96(49) . .
2-1/2/65 3.6(90) 3.36(84) 4.16(104) 2.78(69.5) 2.18(54.5) . .
Primary Materials
Component MaterialBody ASTM B-506
Disc ASTM B-548 EPDM Encapsulated
Upper Stem ASTM A-564 Type XM12
Lower Stem ASTM A-564 Type XM12
Gear HousingCover ASTM A-619
Hand Wheel ASTM A-619
Flag Indicator ASTM B-16
Yoke Mechanism ASTM A-283
Stem Bushing ASTM B-16
Conduit Connector ASTM A-307
O-Rings EPDM Grade"E"
Cover Gasket NBR
Speci f cationsWorking Pressure: 175 PSI (12.5 Bars)Max. Test Pressure: 350 PSI (25.0 Bars)Max. Working Temp.: 250 (120)Factory Installed UL Listed Double Tamper SwitchesValve Approved For Indoor and Outdoor Use
Fig.No.:BT
-14-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
18/38
Wafer Butter y Valve
PN20/300PSI
Dimensions:Size 2"/50 2-1/2"/65 3"/80 4"/100 5"/125 6"/150 8"/200 10"/250 12"/300
A 278 292 298 317 330 343 377 472 518
B 80 89 95 114 127 145 175 223 245C 43 46 46 52 56 56 60 68 78
L1 165 165 165 165 165 165 165 172 193
L2 54 54 54 54 54 54 54 75 78.5
L3 158 158 158 158 158 158 158 230 238
Materials List:
Part Name Material EN Spec. ASTM Spec.Body Ductile Iron EN-JS1050 A536 65-45-12
Shaft S Tainless Steel BS970 420S37 AISI 416
SeatDI EPDM Coated EN-JS1050 A536 65-45-12
DI NBR Coated EN-JS1050 A536 65-45-12
Bushing PTFE Commercial Commercial
O-Ring EPDM/NBR Commercial Commercial
Valve Standards: Complies with EN593/BS5155/MSS SP-67Con rms to LPCB Standard Requirement.Working Pressure and TemperatureWorking Pressure PN20/300PSI.Temperature from -10 to 1 00 for EPDM seat.Temperature from -10 to 82 for NBR seat.Top: Flange: Complies with ISO5211/1.End-To-End Dimensions according to MSS SP-67-2002Flange Types: ANSI B16.1 Class 125/250,EN1092-2 PN10/PN16/BS10 Table EOperator: Gear operator. With two internal CE approved switches.
Fig.No.:2903
-15-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
19/38
Dimensions:
Size 2"/50 2-1/2"/65 3"/80 4"/100 5"/125 6"/150 8"/200 10"/250 12"/300
A 100 106 112.5 135 148.7 176 204 228.1 266.2
B 70 75 82 100 119 130 162 200 224
C 82.4 96.8 96l8 115.85 147.6 147.6 133.4 158.8 163.6
a 16 16 16 16 16 16 19 19 19
Pipe OD 60.3 73.0/76.1 88.9 114.3 139.7/141.3 165.1/168.3 219.1 273.0 323.9
E 136 142 148.5 171 184.7 212 240 265.6 304.7
F 158 158 158 158 158 158 158 230 238
G 54 54 54 54 54 54 54 75 62
H 165 165 165 165 165 165 165 172 193
K 65 65 65 65 65 65 65 75 77
Materials Speci f cations:
Part Name Material EN Spec. ASTM Spec.Body Ductile Iron EN-JS1050 A536 65-45-12
Shaft Stainless Steel BS970 420S37 AISI 416
DiscDI EPDM Coated EN-JS1050 A536 65-45-12
DI NBR Coated EN-JS1050 A536 65-45-12
Bushing PTFE Commercial Commercial
O-Ring EPDM/NBR Commercial Commercial
Valve Standards: Complies with EN593/BS5155/MSS SP-67Con rms to LPCB Standard Requirement.Working Pressure and TemperatureWorking Pressure PN20/300PSI.Temperature from -10 to 10 0 for EPDM seat.Temperature from -10 to 82 for NBR seat.Top: Flange: Complies with ISO5211/1.End-To-End Dimensions according to MSS SP-67-2002Flange Types: Grooved dimensions comply with Metric or ANSI Pipe StandardsOperator: Gear operator. With two internal CE approved switches.
Grooved Butter y Valve
PN20/300PSI Fig.No.:2902
-16-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
20/38
Fireriser Installation Guide
The Fivalco grooved butterfly valve should be connected to the piping system with aprovedcouplings or flange adapters. Flow may be from either direction, and the valve may bepositioned in any direction.
Fivalco butterfly valves have been designed with a slow close hand wheel operator whicheffectively minimizes water hammer. These valves feature minimum ow restriction and pressureloss when in the fully open position.
When the valves are received from the manufacture they should be handled carefully to avoidbreakage and damage to the seating area. Before installation of the valve, clean piping, angeand couping. When the valve closes hard, it is usually due to debris lodged in the sealing area.Often this may be corrected by backing off the hand wheel and closing again.
The valve should never be forced to seat by applying a wrench to the hand wheel as this maydistort the valve componects or score the sealing surface. The use of excessive force to open or close the valve violates all warranties whether express or implied.
The inlet and outlet pipe adjacent to the valve should be properly supported to prevent excessivestress on the valve body. The valve should not be used to force a pipeline into position as thismay result in distortion of the valve body.
Conduit and elecrical connections to the optional tamper switch must be in accordance withNational Electrical Code(NFPA 72)and/or requirements of the local authority having jurisdiction.
Fivalco butter y valves require no regular maintenance, however, it is advisable to inspect andverify proper operation of the unit annually or in accordance with the authorty having jurisdiction.The inspection should include a visual check for leakage at the valve pipe connection and bodyto operator connection.
Inspection and maintenance should be performed by a quali ed inspection service.
Fivalco butterfly valves are provided with internal supervisory position switches. The tamper switch operates by a cam connected to the vallve stem. The switch will change positon andclose within two(2) full turns of the hand wheel from the fully open position.
Fivalco
Design Requirements
Installation
Care & Maintenance
Switch Installaion
Switch#1:
For connection to the supervisory circuit.Normally closed : 2 YellowNormally open : 2 RedCommon : 2 White
Switch#2:
Auxiliary switch connected per authority.Normally closed :1 YellowNormally open :1 RedCommon : 2 WhiteGround Lead : 1 Green
-17-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
21/38
Fireriser Installation, Operation and Maintenance of Resilient-Seated Gate Valves
1. GENERALResilient-seated gate valves form a significant component of many fire-fighting and water-distribution systems. Failure of aresilient-seated gate valve in such systems, either due to faulty installation or improper maintenance, could result in extensivedamage and costly repairs. In addition, many resilient-seated gate valves are installed in buried-service or undergroundapplications. Problems with or malfunctions of the valves due to faulty installation or improper maintenance may result inextensive and costly unearthing operation to effectively correct or eliminate the problem. Many resilient-seated gate-valveproblems and failures can be traced back to improper installation, operation, or maintenance procedures.
2. UNLOADINGAll valves should be unloaded carefully. Each valve should be carefully lowered from the truck to the ground; it should not bedropped. In the case of larger valves, forklifts or slings around the body of the valve or under the skids should be used for unloading. Only hoists and slings with adequate load capacity to handle the weight of the valve or valves should be used. Hoistsshould not be hooked into or chains fastened around yokes, gearing, motors, cylinders, or handwheels. Failure to carefullyfollow these recommendations is likely to result in damage to the valve.
3. INSPECTION PRIOR TO INSTALLATIONResilient-seated gate valves should be inspected at the time of receipt for damage in shipment. The initial inspection should beto verify compliance with speci cations, direction of opening, size and shape of operating nut, number of turns to open or close,and type of end connections. A visual inspection of the seating surfaces should be performed to detect any damage in shipmentor scoring of the seating surfaces. Inspection personnel should look for bent stems, broken handwheels, cracked parts, loosebolts, missing parts and accessories, and any other evidence of mishandling during shipment. Each valve should be operatedthrough one complete opening-and-closing cycle in the position in which it is to be installed.
4. STORAGEValves should be stored in the fully closed position to prevent the entry of foreign material that could cause damage to the
seating surface. Whenever practical, valves should be stored indoors. If outside storage is required, means should be providedto protect the operating mechanism from weather elements. During outside storage, valves should be protected from theweather, sunlight, ozone, and foreign materials. In colder climates where valves may be subject to freezing temperatures, it isabsolutely essential to remove the water from the valve interior and close the valve before storage. Failure to do so may result ina cracked valve casting and or deterioration of the resilient seat material.
5. INSTALLATIONAt the jobsite prior to installation, each valve should be visually inspected and any foreign material in the interior portion of thevalve should be removed. A detail inspection of the valve as outlined in Sec. 3 should be performed prior to installation.
5.1 Bolts all bolts should be checked for proper tightness and protected by the installer to prevent corrosion, either with asuitable paint or by polyethylene wrapping.
5.2 Underground Installation Valves in water-distribution lines shall, where practical, be located in easily accessible areas.
5.2.1 During installation there is the possibility of foreign materials inadvertently entering the valve. Foreign material can damageinternal working parts during operation of the gate valve. For this reason, gate valves should be installed in the closed position.Each valve should be placed on rm footing in the trench to prevent settling and excessive strain on the connection to the pipe.Pipe systems should be supported and aligned to avoid damage to the valve.
5.2.2 A valve box or vault should be provided for each valve used in a buried-service application. The valve box should beinstalled so as not to transmit shock loads or stress to the valve. The valve box should be centered over the operating nut of the valve with the box cover ush with the surface of the nished area or such other level as directed by the owner. Valve boxesshould be of such design that a traf c load on the top of is not transmitted to the valve.
5.2.3 Valves buried in unusually deep trenches should have special provisions for operating the valve either a riser on thestem to permit use of a normal key or a notation on the valve records that a long key will be required.
-18-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
22/38
5.2.4 When valves with exposed gearing or operating mechanisms are installed belowground, a vault designed to allow pipeclearance and prevent settling on the pipe should be provided. The operating nut should be accessible from the top openingof the vault with a valve key. The size of the vault should provide for easy remove of the valve bonnet and internal parts of thevalve for purpose of repair. Consideration should be given to the possible entry of groundwater and /or surface water and to theneed to provide for the disposal of such water.
5.3 Aboveground Installation Valve installed aboveground or in a plant piping system should be supported and aligned to avoiddamage to the valves. Valve should not be used to correct the misalignment of piping.
5.4 Inspection After installation and before pressurization of the valve, all pressure-containing bolting (bonnet, seal plate,packing gland, and end connections) should be inspected for adequate tightness to prevent leakage. In addition, an inspectionshould be made for adequate tightness of all tapped and plugged connections to the valve interior. Proper inspection at this timewill minimize the possibility of leaks after pressurization of the piping system.
5.5 Testing In order to prevent time lost searching for leaks, it is recommended that the
Valve excavations are not back lled until after pressure tests have been made. After installation, it is desirable to test newlyinstalled piping sections, including valves, at some pressure above the system design pressure. The test pressure should notexceed the rated working pressure of the valve. After the test, steps should be taken to relieve any tapped pressure in thebody of the valve. The resilient-seated gate valve should not be operated in either the opening or closing direction at differentpressures above the rated working pressure. It is also recognized that wear or foreign material may damage valve seatingsurfaces and may cause leakage.
5.6 Records On completion of the installation, valve location, size, make, type, date of installation, number of turns to open,direction of opening, and other information deemed pertinent should be entered on permanent records.
5.7 Application Hazards. Resilient-seated gate valves should not be installed in applications or for service other than thoserecommended by the manufacturer.
5.7.1 Resilient-seated gate valves should not be installed in lines where service pressure will exceed the rated working pressureof the valve.
5.7.2 Resilient-seated gate valves should not be used for throttling service unless the design is speci cally recommended for that purpose of approved in advance by the manufacture.
5.7.3 Resilient-seated gate valves should not be used in applications that are exposed to freezing temperature unless suf cientow is maintained through the valve or other protection is provided to prevent freezing.
5.7.4 Gate valves should not be installed at a dead end or near a bend in a pipeline without proper and adequate restraint tosupport the valve and prevent it form blowing off the end of the line.
5.7.5 To prevent damage, 4 and below size NPS resilient-seated gate valves should not be operated with input torques greater than 200 ft-lb (270N.m). Gate valves 6 to 12 NPS should not be operated with input torques greater than 300ft-lb (406N.m).
-19-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
23/38
6. INSPECTION AND MAINTENANCEEach valve should be operated through a full cycle and returned to its normal position on a
time schedule designed to prevent a buildup of tuberculation or other deposits that could render the valve inoperable or preventa tight shutoff. The interval of time between operations in critical locations, or valves subjected to severe operating conditions,should be shorter than that for less important installations, but can be whatever time period is found to be satisfactory basedon local experience. The number of turns required to complete the operation cycle should be recorded and compared withpermanent installation records to ensure full gate travel.
When using portable auxiliary power actuators with input torque capacities exceeding the maximum operating torquesrecommended in Sec. 5.7.5, extreme care should be taken to avoid the application of excessive torque to the valve stem. If theactuator has a torque-limiting device, it should be set below the values in Sec. 5.7.5. If there is no torque-limiting device, therecommended practice is to stop the power actuator three or four turns before the valve is fully opened or fully closed and thencomplete the operation manually.
Maintenance should be performed at the time a malfunction is discovered to avoid a return trip to the same valve and to preventforgetting about it altogether. Recording system should be adopted that provides a written record of valve location, condition,maintenance, and each subsequent inspection of the valve.
6.1 Inspection Each valve should be operated through one complete operating cycle. If the stem action is tight as a result of hard-water buildup on the stem threads, the operation should be repeated several times until the opening and closing actionsare smooth and free. With the gate in the partially open position, a visual inspection should be performed, where practical, tocheck for leakage at all joints, connections, and areas of packing or seals. If leakage is observed, all defective O-rings, seals,gaskets, or end-connection sealing members should be replaced. If leakage can not be corrected immediately, the nature of theleakage should be report promptly to those who are responsible for repairs. If the valve is inoperable of irreparable, its locationshould be clearly established to save time for repair crews. The condition of the valve and, if possible. The gate position, shouldbe reported to personnel responsible for repairs. In addition, fire departments and other appropriate municipal departmentsshould be informed that the valve is out of service.
6.2 Record Keeping In order to carry out a meaningful inspection and maintenance program, it is essential that the location,make, type, size, and date of installation of each valve be recorded. Depending on the type of record-keeping system used,other information may be entered in the permanent record. When a resilient-seated gate valve is inspected, an entry should bemade in the permanent record indicating the date of inspection and condition of the valve. If repair work is necessary, it shouldbe indicated. On completion of the work, the nature of the repairs and date completed should be recorded.
7. RepairsLeakage, broken parts, hard operation, and other major defects should be corrected by a repair crew as soon as possible after the defect has been reported. If repairs are to be performed in the eld, the repair crews should take a full complement of spareparts to the jobsite. Provisions should be made to isolate the defective valve from water pressure and relieve internal trappedpressure prior to performing any corrective maintenance. Disassembly of the valve should be accomplished in accordancewith the procedure supplied by the manufacturer. After repairing the valve, the operating mechanism should be cycled throughone complete operating cycle. With full line pressure applied to the valve in the open position, an inspection should be made todetect leakage in the areas around the seal plate, bonnet, packing gland, and body-end connections. A record should be madeto indicate that the valve has been repaired and is in working condition. Any markings indicating that the valve is inoperableshould be removed. In addition, fire departments and other appropriate municipal departments should be informed of thesatisfactory repair of the valve.
-20-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
24/38
Fireriser Butter y Valve
Butter y Valves Packing
Fire y
BT & BG Bronze Butter y ValvesUL Listed FM Approved
Nom.PipeSize
EndConnection
QuantityCarton/
Case
WeightEach
WeightCarton/
CaseIn. mm Lbs./kilos Lbs.kilos1" (25) TH 4 3.4/1.5 13.6/6.0
1-1/4" (32) TH 4 3.7/1.7 14.8/6.8
1-1/2" (40) TH 4 4.1/1.9 16.4/7.6
2" (50) TH 4 501/2.3 20.4/9.2
2-1/2" (65) TH 4 6.7/3.0 26.8/12.0
2" (50) GR(M) 4 5.0/2.3 20.0/9.2
2-1/2" (65) GR(M) 4 5.7/2.5 22.5/10.0
Fireriser DG & HDG Ductile Iron Body Butter y ValvesGrooved Cases Only
2-1/2 (65) GR 50 20.0/9.0 1050/475
2-1/2 (76M) GRM 50 20.0/9.0 1050/475
3 (80) GR 50 21.0/9.5 1100/500
4 (100) GR 40 25.0/11.5 1080/480
6 (150) GR 24 39.0/17.5 912/408
6 (165M) GRM 24 39.0/17.5 912/408
8 (200) GR 24 51/0/23 1176/528
10 (250) GR 10 68.0/40.5 680/405
12 (300) GR 10 118.0/53.5 1180/535
Fireriser DW & HDW Ductile Iron Body Butter y ValvesSuitable for ANSI B16.1 125,DIN 2633 ft DN2501 PN16Water British Standard 4504 /PN 16 Flanges
2-1/2 (65) w 50 20.2/9.2 1050/475
3 (80) w 50 20.5/9.3 1050/525
4 (100) w 40 22.0/10.0 1000/400
6 (150) w 30 32.0/14.5 960/435
8 (200) w 24 41.0/19.0 1032/468
Note :GR-Grooved End.GRV-Grooved Metric End.Crate Dimensions: 2-1/2 to 4 Crate Dimensions: 6 and 8 Crate Dimensions: 10 and 12
TH--Threaded End W-Wafer Type.THM Threaded Metric End.(1.10m LX1.10m W X0.61mm H)(1.10m LX1.10m W X0.76mm H)TBA
-21-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
25/38
(FRICTION LOSS TEST)
Model in/mm Hose assemblylength, ft (m)Equivalent Length of 1in.Schedule 40 Pipe, ft (m)
FX(B)-07 1/2(15mm) 2 (0.6) 13.7(4.1)
FX(B)-08 1/2(15mm) 2.6 (0.6) 17.9(5.4)
FX(B)-10 1/2(15mm) 3 (0.8) 22.2(6.7)FX(B)-12 1/2(15mm) 4 (0.9) 37.0(11.2)
FX(B)-15 1/2(15mm) 4 (1.2) 45.5(13.8)
FX(B)-18 1/2(15mm) 6 (1.5) 63.0(19.2)
FX(B)-07 3/4(20mm) 2 (0.6) 10.5(3.2)
FX(B)-08 3/4(20mm) 2.6 (0.6) 14.4(4.4)
FX(B)-10 3/4(20mm) 3 (0.6) 18.3(5.6)
FX(B)-12 3/4(20mm) 4 (0.6) 32.8(10.0)
FX(B)-15 3/4(20mm) 5 (0.6) 43.2(13.1)
FX(B)-18 3/4(20mm) 6 (0.6) 58.7(17.9)
Anchoring components are intended for use with drop ceilings conforming to ASTM C635 and other major standards wheninstalled in accordance with the Standard Practice for installation of Metal Ceiling Suspension Systems for Acoustical Tile andLay-In Panels, ASTM C636 or other equivalent standards
Technical DateRated Pressure:175PSIMaximum Ambient Temperature : 225( ), 170 ( )Maximum Sprinkler K-factor for 1/2 in. outlet: 5.6gal/mm/(psi)1/2Maximum Sprinkler K-factor for 3/4 in. outlet: 8.0gal/mm/(psi)1/2Designed for use in Wet and Dry Systems
Minimum Bend Radius: 8In/200mm
Maximum Number of bends.3 bends for 1200-1800mm lengths2 bends for 800~950mm lengths1 bend for less than 800mm
Component List:
NO Part Name Material Qty.1 Flexible Tube SS304 1
2 Nut S10C 2
3 Isolation Ring Nylon66 1
4 O-Ring Silicon 1
5 Reducer Zinc Plated Steel 1
6 Nipple Zinc Plated Steel 1
7 Center Bracket Zinc Plated Steel 1
8 End Bracket Zinc Plated Steel 2
9 Square Bar Zinc Plated Steel 1
Quickonnect TM Flexible Sprinkler Connector
-22-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
26/38
FXB: BRAIDED TYPE FX: UNBRAIDED TYPENOTES: NPT + METRIC THREADS AVAILABLE: SPECIFY WHEN ORDERING-Packing : 20 pieces per carton per each size -
(C.Connecting The Square Bar To The Celling Structure)
Assembly Instructions(A.Connecting The Reducer)
Disconnect the reducer by turning the Nut (not theReducer) from the Flexible Hose.
Check that Gasket and Isolation ring are properlyin place. Reconnect the Reducer to the FlexibleSprinkler by turning the Nut. Two open endedspanners (or adjustable wrenches) should be used totighten the nut to ensure a leak proof connection.
Do not over tighten.
(B.Connecting The Nipple To The Piping)Disconnect the Nipple from the FlexibleSprinkler. Connect the Nipple to the mainpiping with normal sealing proceduresand tighten using a pipe wrench toensure a leak-proof connection. Donot over tighten. Connect the Flexiblehose to the Nipple by finally tighteningthe nut. Make sure gasket and isolationring are properly located at the end of the Flexible hose before connecting thehose to the main piping system
Place the two End brackets properly in position. Push the endbrackets into the ceiling structure rails and check the end bracketssit securely on the rails.
Fasten the wing bolts on the side of the End brackets nger tight.
Do not over tighten
Insert the reducer from the side of the center bracket in a horizontal direction (not fromthe top vertically). Adjust the angle of thereducer by turning it gently into the bracket.
Do not over tighten
Quickonnect TM Flexible Sprinkler Connector
Installation Instructions
-23-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
27/38
Working Pressure And Temperature:300PSI/21Bars with water Available as standard with threaded connections NPT/BSPTOther Thread types/end connections available for speci c markets
Optional Finishes:Forged Finish / Polished/ Forged Chrome Plated /Forged Polished Chrome Plated
Material Speci f cations:
Component Material ASTM SpecifcationBody Forged Brass ASTM B16
Bonnet Forged Brass ASTM B16
Nut Forged Brass ASTM B16
Handwheel Cast Iron ASTM A48 Class 35
Stem High Tensile Brass ASTM B16
Seat PTFE Commercial
Washer High Tensile Brass ASTM B16
O-Rings FPM Commercial
Forged Brass Fire Hose Valve
FM Approved
Dimensions (in/mm):
SIZE 1-1/2"/40 2-1/2"/65
L 2.17/55 3.15/80
H(Open) 7.70/195.5 10.69/272
H(Closed) 6.61/168 8.9/226
Forged Brass ConstructionEliminates Pinholes and leaks compared with lower quality cast brass construction.PTFE seat for longer service life
FM ApprovedAvailable with Male or Female Threaded Outlet as standard. Approval tested at 4Times working pressure = 1200 PSI/83 Bars; Production tested at twice workingpressure 600PSI/41 Bars
Figure No.:FH-1
-24-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
28/38
Valve Standards:Conforms to MSS SP 110
Working Pressure And Temperature:Working Pressure: PN40 150WSP/600 WOGLever hand operation
Material Speci f cations
Component MaterialBody B16 C36000 Brass
Seat Seal PTFE
Ball B16 C36000 Brass
Cap B16 C36000 Brass
Packing PTFE Commercial
O-Ring FPM Commercial
Packing PTFE Commercial
Nut B16 C36000 Brass
Stem B16 C36000 Brass
Nut Steel
Handle Steel/PVC
UL Listed Trim Valves
Brass Ball Valve
Dimensions (mm)
SIZE 1/2"/15 3/4"/20 1"/25 1-1/4"/30 1-1/2"/40 2"/50
L1 59 67 77 90 100 100
H 50 58 63 78 89 96L 16 17 19 21 22 24
Notes:Approved under the SAFT brand - A Fivalco company.
Features and Bene f tsSturdy, High Quality construction from superior corrosion resistant materialsFull Port -no pressure lossManufactured by Fivalco- a leader in the demanding Fire Protection Industry
Fig No. S2130-00
-35-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
29/38
Valve Standards:BS/EN 13789/MSS SP85
Working Pressure and Temperature:Working Pressure: PN 20 125WSP 200WOGWorking Temperature: -10 to180
Materials Speci f cations:
Component MaterialBody Copper alloy ASTM B16 C36000
Clamping Nut Brass
Clamping Ring Brass
Seat Seal PTFE Commercial
Holder Copper alloy ASTM B16
Bonnet Copper alloy ASTM B16
Stem Copper alloy ASTM B16
Packing PTFE
Packing Nut Copper alloy ASTM B16
Packing Ring Brass
Hand Wheel Cast Iron
Nam Plate Aluminium
Wheel Nut Brass
UL Listed Trim Valves
Brass Globe Valve
Dimensions (mm):
SIZE 1/2"/15 3/4"/20 1"/25 1-1/4"/30 1-1/2"/40 2"/50
L 50 55 64 73 84 90
L1 10.5 10.5 12.5 14 15 16
H 64 69 82 94.5 107 120
L2 53.5 53.5 57.5 71.5 71.5 77.5
Notes:Approved under the SAFT brand - A Fivalco company.
Features and Bene f tsSturdy,High Quality construction from the best corrosion resistant materialsRenewablePTFE Seat Manufactured by Fivalco- a leader in the demanding FireProtection Industry
Fig No. SVC1314-00
-26-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
30/38
Material Speci f cations:
Component MaterialBody Copper alloy ASTM B16
Clamping Nut Brass ASTM B16
Clamping Ring Brass ASTM B16
Seat Seal PTFE Commercial
Holder Copper alloy ASTM B16
Bonnet Copper alloy ASTM B16
Stem Copper alloy ASTM B16
Packing PTFE Commercial
Packing Nut Copper alloy ASTM B16
Hand Wheel Cast Iron
Nam Plate Aluminium
Wheel Nut Brass
UL Listed Trim Valves
Angle Globe Valve
Dimensions (mm):SIZE 1/2"/15 3/4"/20 1"/25 1-1/4"/30 1-1/2"/40 2"/50
L 50 55 64 73 84 90
L1 10.5 10.5 12.5 14 15 16
H 64 69 82 94.5 107 120
L2 53.5 53.5 57.5 71.5 71.5 77.5
Notes:Approved under the SAFT brand - A Fivalco company.
Features and Bene f tsSturdy,High Quality construction from the best corrosion resistant materialsRenewablePTFE Seat Manufactured by Fivalco- a leader in the demanding FireProtection Industry
Valve Standards:BS/EN 13789/MSS SP85
Working Pressure and Temperature:Working Pressure: 300PSIWorking Temperature: -10 to180
Fig No. SVC1313-00
-27-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
31/38
Material Speci f cations:
Part Name Material EN Spec. ASTM Spec.Body Cast Iron EN-JL1040 A126 Class B
Cover Cast Iron EN-JL1040 A126 Class B
Lever Frame Stainless Steel BS970 304S15 AISI 304
Float ball Stainless Steel BS970 304S15 AISI 304
Gasket Stainless Steel BS970 304S15 AISI 304
Cover Bolt Carbon Steel Carbon Steel A307 B
Float Arm Stainless Steel BS970 304S15 AISI 304
Orice Button Viton Commercial Commercial
Pivot Pin Stainless Steel BS970 304S15 AISI 304
Pin Retainer Stainless Steel BS 970 304S15 AISI 304
Plug Brass CuZn39Pb3 B16 C36000
Locator Stainless Steel BS970 304S15 AISI 304
Automatic Air Vent Valve
PN 16/Class 125/ 235 PSI
Dimensions (mm):
SIZE 1/2"/151/2" 1/2 BSP or NPT
3/4" 3/4 BSP or NPT
1" 1 BSP or NPT
Working Pressure and TemperatureWorking pressure PN16/Class 125./235 PsiTemperture from -10 to 120 .
Fig. 9701
-28-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
32/38
Breeching inlets are provided to give Fire Brigade access to riser systems in theevent of a re.Our products are manufactured and tested in accordance with BS 336/5043.Constructed of high quality materials from Fivalco a leader in the Fire Protection Industry.
Materials List:
No Component Material1 Body Cast iron ASTM A126 Class B
2 1" Couplling Steel Commercial
3 1" Gate valve Brass B16
4 Plug Plastic
5 Chain Steel Commercial
6 Chain Steel Commercial
7 Coupling Brass B16
8 M10 Nut Brass B16
9 Spring Steel Commercial
10 Stem Steel Commercial
11 O Ring NBR Commercial
12 Gasket NBR Commercial13 Valve Seat EPDM Commercial
14 Chain Steel Commercial
15 Gasket EPDM Commercial
Two Way Breeching Inlet
Dimensions:
Flange Size A B C 4/100 222 180 100
Notes:1.Hydraulic test 2.5MPA.2.Painting red RAL 3000.3.All dimensions in mm.4.Flanges are PN16
Figure No.:BRE-2
-29-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
33/38
Breeching inlets are provided to give Fire Brigade access to riser systems in theevent of a re.Our products are manufactured and tested in accordance with BS 336/5043.Constructed of high quality materials from Fivalco a leader in the Fire Protection Industry.
Materials List:
No Component Material1 Body Cast iron ASTM A126 Class B
2 1"Couplling Steel Commercial
3 1"Gate valve Brass B16
4 Plug Plastic
5 Chain Steel Commercial
6 Chain Steel Commercial
7 Coupling Brass B16
8 M10 Nut Brass B16
9 Spring Steel Commercial
10 Stem Steel Commercial
11 O Ring NBR Commercial
12 Gasket NBR Commercial
13 Valve Seat EPDM Commercial
14 Chain Steel Commercial
15 Gasket EPDM Commercial
Four Way Breeching Inlet
Dimensions:
Flange Size A B C L
6"/150 285 240 150 265
Notes:1.Hydraulic test 2.5MPA.2.Painting red RAL 3000.3.All dimensions in mm.4.Flanges are PN16.
Figure No.:BRE-4
-30-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
34/38
Materials List:Component Material
Handwheel DI ASTM ASS6-65-45-12
Chain Commercial Steel
Stem Brass B16
Plug Brass B16
O-Ring EPDM
Body Seal EPDM
O-Ring EPDM
Valve Body Brass B16Bolts Commercial Steel
Spring Tempered Steel
Nut Commercial Steel
Cap Brass B16
Coupler Seal Coupler
Landing Valves
Landing valves 2-1/2 BS Flanged
Dimensions (mm)
Size D H L2-1/2/65 13 188 164.5
Figure No.:LVF
-31-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
35/38
Materials List:Component Material
Handwheel DI ASTM ASS6-65-45-12
Chain Commercial Steel
Stem Brass B16
Plug Brass B16
O-Ring EPDM
Body Seal EPDM
O-Ring EPDM
Valve Body Brass B16Bolts Commercial Steel
Spring Tempered Steel
Nut Commercial Steel
Cap Brass B16
Coupler Seal Coupler
Landing Valves
Landing valves 2-1/2 BS Threaded
Dimensions (in/mm)Size H
2-1/2/65 207
Figure No.:LVS
-32-
Fivalco and Fireriser are Registered Trade Marks Copyright Fivalco 2006
Fivalco
-
8/2/2019 Fpp Catalogue 2012
36/38
Fivalco Inc. Limited Warranty
Fivalco Inc, warrants each metal valve to be free from defects in material and workmanship under normal use and service for aperiod of one year from the date of purchase.
In the event that any defect is discovered which may be covered by this Warranty, the owner should contact Fivalco Inc, inwriting or by telephone.
The owner may be instructed to return the valve at owner's expense to Fivalco Inc, or an authorized Fivalco location for inspection. In the case that inspection reveals that the valve is defective it will be replaced at Fivalco Inc.'s expense.
Replacements shall be shipped free of charge to the owners provided that the valve was installed in accordance with FivalcoInc. Instructions and in accordance with the local authority having jurisdiction.
To the extent permitted by law this warranty specifically excludes incidental and consequential damages of every type anddescription resulting from any claimed defect in material or workmanship, including, but not limited to, personal injuries andproperty damages. To the extent permitted by law, implied warranties of merchantability and tness for particular purposes are
limited in duration.
Some jurisdictions do not allow exclusion or limitation of incidental damages and such limitations may not apply to you.
This warranty provides the owner with speci c legal rights and owners may have other rights which vary by jurisdiction
Distributed By:
-33-