Download - FLOOR PLAN N - LoopNet
(E)
(E)
(E)
(N)
(N)
(N)
(N)
(N)
(E)
(E)
(E)
(E)
(E)
(E)
150 CFM
150 CFM
75 CFM
(N)
10
'-0
"
Office 1
Break Room Office 5
Office 2 Office 3 Office 4
Bath
GYM
3'-0
"4
'-1
"1
6'-0
"
25'-9
1
2
"
23'-8" 15'-0"
18'-0"
12'-10
1
2
"
11'-10" 12'-0"
13
'-0
"4
'-6
"1
8'-0
"
5'-6
3
4
"
4'-6
"
11'-8
1
8
"
5'-0
5
8
"
7'-6
"
A
B
EX
C
6
1
11
1
2
3
2
2
4
4
5
2
6
A
Billiard
0"
2'-10"
5'-6
5
8
"
8"
3'-10"
8"
2'-2
3
8
" 12'-10
1
2
"
3'-0
"
N
D
E
E E
EE E
E
E
E
B
B
A
B
B
B
A
6'-0"
5"5"
5"
5"
2'-0
"
A-101
5"
5"
4"
6"
6'-7
3
8
"
2
5"
SCALE: 1/4"=1'-0"
FLOOR PLAN
1
A-201
1
A
WALL TYPE LEGEND
MARK
B
C
TENANT SEPARATION WALL - EXISTING 1 HR RATED STUD WALL PARTITION TO REMAIN. GC SHALL INSPECT
EXISTING WALL AND REPAIR AS REQUIRED TO ACHIEVE 1 HR RATING. SEAL PENETRATIONS PER
THROUGH-WALL PENETRATION DETAILS.
CODE REQUIREMENTS FOR SOUND CONTROL OF INTERIOR ASSEMBLIES:
WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND
TRANSMISSION CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. PENETRATIONS OR
OPENINGS IN CONSTRUCTION ASSEMBLIES FOR PIPING; ELECTRICAL DEVICES; RECESSED CABINETS; BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR EXHAUST
DUCTS SHALL BE SEALED, LINED, INSULATED OR OTHERWISE TREATED TO MAINTAIN THE REQUIRED RATINGS. THIS REQUIREMENT SHALL NOT APPLY TO DWELLING
UNIT ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT FITTING TO THE FRAME AND SILL.
IN ADDITION, FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE
SHALL HAVE AN IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
TYPICAL INTERIOR STUD WALL, INSTALL 5/8" GYP. BD. (TOUGH ROCK FIREGUARD X W/ MOLD-GUARD) ON BOTH
SIDES OVER METAL STUDS. INSTALL 5/8" DUROCK AT WET AREAS OR AREAS RECEIVING TILE / STONE /
PORCELAIN. PROVIDE BLOCKING OR BACKING AS REQ'D FOR BATHROOM GRAB BARS AND ACCESSORIES.
STEEL SHEET METAL IS ALSO ACCEPTABLE AS BACKING MATERIAL. PROVIDE SOUND ATTENUATION BLANKETS.
SEE PARTITION DETAILS.
INTERIOR PARTITION NOTES:
1. ALL METAL FRAMING FOR PARTITIONS SHALL EXTEND FROM FLOOR STRUCTURE TO STRUCTURE ABOVE UNLESS NOTED OTHERWISE.
2. ALL INTERIOR PARTITIONS AND DROP CEILING SOFFITS SHALL RECEIVE SOUND ATTENUATION BLANKETS.
3. CAULK AND SEAL ALL PENETRATIONS AND JOINTS WITH ACOUSTICAL SEALANT.
4. PROVIDE OPTION TO OWNER FOR INSTALL OF RESILIENT CHANNELS ON ONE SIDE OF ALL NEW INTERIOR PARTITIONS, INSTALLED PER
MANUFACTURER'S SPECIFICATIONS.
5. GLASS USED IN HAZARDOUS LOCATIONS AS DEFINED BY FBC 2406.4 SHALL BE CATEGORY II SAFETY GLASS IN COMPLIANCE WITH FBC CHAPTER
2406.
6. INTERIOR WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD INDEX OF 200 OR LESS AND A SMOKE-DEVELOPED INDEX OF 450 OR LESS
WHEN TESTED IN ACCORD WITH ASTM E 84 OR UL 723. SEE FBC SECTION 803 FOR EXCEPTIONS AND OTHER TESTING METHODS FOR APPROVED USE
OF MATERIALS.
DENOTES RATED INTERIOR PARTITION
DENOTES INTERIOR PARTITION
FLOOR PLAN LEGEND
EX
RECESSED FIRE EXTINGUISHER GC. SHALL
VERIFY COMPLIANCE WITH NFPA 1 - 13.6.1.2
FOR APPROPRIATE HAZARD TYPE. FIRE
EXTINGUISHER SHALL BE TAGGED AND UP TO
DATE BY A LICENSED FIRE-EXTINGUISHER
COMPANY. GC SHALL REQUEST WORK ORDER
TO BUILDING MANAGEMENT FOR OUT OF DATE
EXISTING FIRE EXTINGUISHERS
EXISTING CURTAIN WALL SYSTEM TO REMAIN
DGLASS FRAMELESS SHOWER ENCLOSURE CATEGORY II SAFETY GLASS
EFRAME PER WALL TYPE B INCLUDING NEW CATEGORY II SAFETY GLASS WINDOW SEE DETAILS.
6 3-0 x 7-0 1 3/4" PAINTED METAL UL LABEL C 3/4 HR W/ CLOSER
INTERIOR DOOR SCHEDULE
SIZE FINTHK REMARKS
2 3-0 x 7-0 1 3/4" GLASS FRAMELESS GLASS DOOR W/ PATCH FITTING
3 5-0 x 7-0 1 3/4" GLASS DOUBLE FRAMELESS GLASS DOOR W/ PATCH FITTING
1 3-0 x 7-0 1 3/4" PAINTED WOOD FRENCH DOOR
5 2-2 x 7-0 1 3/4" PAINTED SOLID CORE PANEL DOOR
4 2-10 x 7-0 1 3/4" PAINTED SOLID CORE PANEL DOOR
6"
4"
5'-0
5
8
"
4"
6" 3'-0"
2'-9
3
8
"
2'-0"
7'-6"
5"
4'-1"
5"
3'-0"
5"
1'-11"
2'-2"
5"
6"
2'-2"
4"
5"
4'-3
3
8
"
Bath
5'-0"
A-201
A
B
RE
VIS
IO
NS
BY
DA
TE
ST
AR
T D
AT
EV
VR
C5
/4
/17
AL
L ID
EA
S, D
ES
IG
NS
, A
RR
AN
GE
ME
NT
S,
&
P
LA
NS IN
DIC
AT
ED O
R R
EP
RE
SE
NT
ED B
Y T
HIS D
RA
WIN
G A
RE O
WN
ED B
Y, &
T
HE P
RO
PE
RT
Y O
F T
HE A
RC
HIT
EC
T &
W
ER
E C
RE
AT
ED
, E
VO
LV
ED
, &
D
EV
EL
OP
ED F
OR U
SE O
N, &
IN
C
ON
NE
CT
IO
N W
IT
H T
HE S
PE
CIF
IE
D P
RO
JE
CT
. N
ON
E O
F S
UC
H ID
EA
S, D
ES
IG
NS
, A
RR
AN
GE
ME
NT
S,
O
R P
LA
NS S
HA
LL B
E U
SE
D B
Y, O
R D
IS
CL
OS
ED T
O A
NY P
ER
SO
N,
F
IR
M, O
R C
OR
PO
RA
TIO
N F
OR A
NY P
UR
PO
SE W
HA
TS
OE
VE
R W
IT
HO
UT T
HE W
RIT
TE
N P
ER
MIS
SIO
N O
F B
RIA
N IR
A B
UL
LO
CK
,
AR
CH
IT
EC
T. W
RIT
TE
N D
IM
EN
SIO
NS
O
N T
HE
SE
D
RA
WIN
GS
S
HA
LL
H
AV
E P
RE
CE
DE
NC
E O
VE
R S
CA
LE
D
IM
EN
SIO
NS
. C
ON
TR
AC
TO
RS
S
HA
LL
V
ER
IF
Y &
B
E R
ES
PO
NS
IB
LE
F
OR
A
LL
D
IM
EN
SIO
NS
&
C
ON
DIT
IO
NS
O
N T
HE
J
OB
. T
HE
A
RC
HIT
EC
T M
US
T B
E N
OT
IF
IE
D O
F A
NY
V
AR
IA
TIO
NS
F
RO
M T
HE
D
IM
EN
SIO
NS
A
ND
C
ON
DIT
IO
NS
S
HO
WN
B
Y T
HE
SE
D
RA
WIN
GS
. S
HO
P D
ET
AIL
S O
F A
DE
QU
AT
E S
CA
LE
M
US
T B
E S
UB
MIT
TE
D T
O T
HE
A
RC
HIT
EC
T F
OR
A
PP
RO
VA
L B
EF
OR
E P
RO
CE
ED
IN
G W
IT
H F
AB
RIC
AT
IO
N O
N IT
EM
S S
O N
OT
ED
.
PROJECT NO. DRAWN BY
BP1634VVRC
Office
R
en
ov
atio
n
14
89
W
. P
alm
etto
P
ark
R
oa
d, 5
th
F
lo
or, B
oca
R
ato
n, F
L
ARCHITECT'S SEAL
6-14
-2
017
- F
OR
R
EV
IE
W - N
OT
F
OR
C
ON
ST
RU
CT
IO
N
BRIAN BULLOCK, ARCHITECT
AR 95754
A B C D
ARCHITECTURE PLANNING
1525 NW 3RD STREET SUITE NO.1DEERFIELD BEACH, FLORIDA 33442
www.thebenedictgroup.com Lic. No. AA 26003089
TheBenedictBullock
Group, PA
(954) 570-9500 FAX (954) 570-9550
A-101
SCALE 1/2"-1'-0"
BATHROOM DETAIL
2