ACUTE NIV
Hospital Long Term Care
EmergencyHome Care
Greater Flexibility andImproved OutcomeFlight 60T provides care givers the high degree of autonomy and ability to focus on what is most important for their patients with minimal equipment modifications
ICU Quality Ventilation AnywhereHospital
- Acute Care, ER, Transport, Step Down
EMS and Transport
Emergency and PreparednessHome care
CCV - Continuity of Care Ventilation
Flight F60 T Critical Care andAcute Noninvasive Ventilation
TURBINE
Flight 60T is an acute care ventilator that offers Flexibility and Mobility, with uninterrupted Continue of Care Ventilation in every clinical setting
Your Partner in Ventilation
LIT-
0111
Rev
A01
USA
201
6
0483
Flight Medical Innovations Ltd.www.flight-medical.com
FLIGHT 60 Technical SpecificationsTurbine Configuration
ALARMS (automatic)Check Circuit (Circuit Disconnect), Low/Empty Battery, O2 Supply Failed, Check O2 Sensor, Target Volume not reached
MONITORED PARAMETERSWaveforms Pressure, Flow, VolumeLoops Pressure/Volume & Flow/Volume
Trends Rate, Peak Inspiratory Pressure & Vte (up to 72 hours)
Airway Pressure LED Gauge -10 to 120 cmH2OPeak Inspiratory Pressure 0 to 120 cmH2OBase Pressure 0 to 99 cmH2OMean Pressure 0 to 99 cmH2OExhaled Tidal Volume 0 to 10LExhaled Minute Volume 0 to 99LInhaled Tidal Volume 0 to 10LInhaled Minute Volume 0 to 99LActual Breath Rate 0 to 99 b/minPeak Inspiratory Flow 1 to 120 L/minRSBI 0 to 200 1/min*L FiO2 21% to 100%I:E Ratio 1:99 to 3:1Battery Level 100% to 0%, Low, EmptySPECIAL FUNCTIONSBuzzer Level LOW/HIGH
Keypad Buttons Keypad buttons with audible indicator
Power Save ON/OFF/NIGHT
LanguagesEnglish, French, German, Greek, Hungarian, Italian, Polish, Portu-guese, Russian, Spanish, Turkish
Quick Start 5 preset ventilation modesSIZE AND WEIGHTDimensions (WxLxH) 29 x 28 x 25 cm / 11.4” x 11.0”x 9.8”
Weight 5.5 Kg / 12 lbs6.0 Kg / 13.3 lbs (with integrated mixer)
OXYGEN
O2 Mixer (optional) Internal integral, electronically controlled
High Pressure 35 to 90 psi Low Flow Port 0 to 15 L/min Low Flow Blending Bag 0 to 15 L/min POWER SUPPLYAC Power Inlet 100 to 240 VAC, 50-60HzDC Power Inlet 12 to 15 VDCInternal Batteries Hot Swappable 8 hours operationCharging Time Up to 3 hoursCOMMUNICATIONSUSB x2 Download Logs, SW UpgradeRS232 x2 Remote Alarm and MonitoringENVIRONMENTALOperation Temperature -18OC to 50OC / -0.4OF to 122OFStorage Temperature -20OC to 71OC / -4.0OF to 160OFRelative Humidity 15% to 95% at 31OC / 88OFOperation Altitude 110 kPa to 70 kPaWater/Dust Resistance IP34 (splash proof)STANDARDS
IEC 60601-1 ,IEC 60601-1-2 ,IEC 60601-2-12, ASTM 1246F ,ISO 10651-2/3, RTCA DO-160 F
MODES ACMV - PCV/VCV/PRVCSIMV - PCV/VCV/PRVCSPONT (CPAP, BPAP)Volume GuaranteeB-Lev (Bi-Phasic, APRV)
CONTROLS
NPPV OFF/LOW/HIGH(leak compensation up to 60 LPM)
VG Mode VtG (Tidal Volume Guarantee) MVG (Minute Volume Guarantee)
SIGH ON/OFF2min 100% O2 Function ON/OFFTidal Volume 30 to 2,200 mlBreath Rate 1 to 99 b/minInspiration Time (Ti) 0.1 to 3.0 secFlow 2 to 220 L/minPressure Control 5 to 80 cmH2OPressure Support (PSV) 0 to 60 cmH2OPEEP/CPAP 0 to 40 cmH2OPressure Trigger -20.0 to -0.1 cmH2OFlow Trigger 1 to 20 LPMRise Profile 5 levelsPSV Ti 0.1 to 3 secPSV Flow Termination 10% to 90%Volume Control Time/FlowFlow Waveform Square/DescendingFiO2 21% to 100%FiO2 Sensor ON, OFF, CalibrateManual Breath 0 to 3 secPanel Lock ON/OFFTrends ON/OFF/ClearVG Mode ControlsTarget VtG 30 to 2,200 mlPSV min 0 to 60 cmH2OPSV max 5 to 60 cmH2OTrigger Delay ON/OFFB-Lev ControlsP High 3 to 60 cmH2OP Low 0 to 30 cmH2OT High (Ti) 1 to 15 secT Low 0.5 to 5 secInverse I:E 30:1ALARMS (variable)Alarm Prioritization 3 Levels – Caution, Medium, HighLow Minute Volume 0.0 to 50 L/minLow Pressure OFF, 1 to 98 cmH2OHigh Pressure 4 to 99 cmH2OHigh Minute Volume 0.1 to 50 L/minHigh FiO2 31% to 99%, OFFLow FiO2 OFF, 22% to 90% High Rate OFF, 1 to 99 bpmLow Rate OFF, 1 to 99 bpmLow Vte OFF, 10 to 2,200mlLow Vti OFF, 10 to 2,200mlApnea/Back-Up Ventilation 10-60 sec
* NOTE: Some features of the Flight 60 may not be available or cleared in all countries. For detailed information, contact your local Flight Medical representative.