Download - FISCAL METERING SYSTEM DESIGN - Cost/Benefit
![Page 1: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/1.jpg)
FISCAL METERING SYSTEM DESIGN - some design evaluations with respect to lifecycle cost/benefit
NFOGM Temadag, Sola, 22 March 2012
Morten Marstein, Senior Systems Engineer, FMC Kongsberg Metering AS
![Page 2: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/2.jpg)
Design Categories
Case: Liquid Metering Station
• Design
– Conventional liquid metering station with volume prover
– Liquid metering station with master meter and portable prover connections
– Liquid metering station with master meter (no inline proving)
– Multi-phase metering
• Configuration
– Serial configuration
– Parallel configuration
– Z-configuration
![Page 3: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/3.jpg)
Evaluation Criterias
• Price and delivery time (project phase)
– Cost of parts, engineering, complexity
• Accuracy
– Conformance to fiscal accuracy requirements
• Functionality
– Flow range, online maintenance, online calibration, online diagnostics
• Reliability / Maintenance cost
– Maintenance and diagnostics facilities, complexity, maintenance intervals, knowledge for maintenance
![Page 4: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/4.jpg)
Evaluation – Design Categories
Price and delivery time
Accuracy
Functionality
Reliability / Maintenance
Sum
Conventional with volume prover
- + + - 0
Master meter and portable prover connections
0 0 + + ++
Inline meters only
+ - - - --
Multi-phase metering
+ - 0 - -
+ Advantage
- Disadvantage
![Page 5: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/5.jpg)
Liquid Metering Station with Prover
![Page 6: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/6.jpg)
Liquid Metering Station with Master Meters
![Page 7: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/7.jpg)
Liquid USM Metering Station - no master meter or proving facility
![Page 8: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/8.jpg)
Multiphase Metering
![Page 9: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/9.jpg)
Evaluation – Design Configuration
Price and delivery time
Accuracy
Functionality
Reliability / Maintenance
Sum
Serial configuration
+ + + - ++
Parallel configuration
0 + 0 0 +
Z-configuration
- + + + ++
![Page 10: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/10.jpg)
Serial vs. Parallel Configuration
0
0,2
0,4
0,6
0,8
1
1,2
-1 -0,5 0 0,5 1
Rel.
co
mb
. std
. u
nc
ert
ain
ty
[%]
Correlation
Two meters in series
0
0,2
0,4
0,6
0,8
1
1,2
0 20 40 60 80 100
Rel. c
om
b.
std
. u
ncert
ain
ty
[%]
Percentage of flow in pipe 2
Two meters in parallel
![Page 11: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/11.jpg)
Flow Measurement Technologies
• Liquid
– PD (Positive Displacement) Meters
– Turbine Meters
– Ultrasonic Meters
– Coriolis Meters
• Gas
– DP Meters (Orifice, Venturi)
– Cone Meters
– Ultrasonic
– Coriolis
![Page 12: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/12.jpg)
Evaluation – Flow Measurement Technologies - Liquid
Price and delivery time
Accuracy
Functionality
Reliability / Maintenance
Sum
Liquid PD - + 0 0 0
Liquid Turbine
0 + 0 + ++
Liquid Ultrasonic
0 0 + 0 +
Liquid Coriolis
+ 0 + + +++
![Page 13: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/13.jpg)
PD Metering Station
![Page 14: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/14.jpg)
Coriolis Metering Station
![Page 15: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/15.jpg)
Evaluation – Flow Measurement Technologies - Gas
Price and delivery time
Accuracy
Functionality
Reliability / Maintenance
Sum
Gas DP 0 - - + -
Gas Cone + - - + 0
Gas Ultrasonic
0 + + - +
Gas Coriolis + 0 + 0 +
![Page 16: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/16.jpg)
Gas Metering Stations
![Page 17: FISCAL METERING SYSTEM DESIGN - Cost/Benefit](https://reader034.vdocuments.us/reader034/viewer/2022042503/5883208f1a28aba0198bb1cd/html5/thumbnails/17.jpg)
Important Issues in the Project Phase
• Metering knowledge at Operator / Contractor
• Calibration arrangement (provers, master meters)
• Proven technology
• Combine measurement techniques
• Quality (fluid property) measurements
Preferred solution:
• Solid technical design based on proven technology including inline calibration/verification arrangement