FIRE SAFETY
Part B Building Regulations
David Cant
Health and Safety Consultant
www.veritas-consulting.co.uk
![Page 2: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/2.jpg)
• Part B: Fire Safety
• Regulatory Reform (Fire Safety) Order 2005
• Fire Safety Guidance Documents
• Transitional Provisions
• Oil Fired Boilers
• Revised Building Control Charges
• Revised Building Control Forms
![Page 3: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/3.jpg)
Coming into force on the 6th April 2007
New Regulation 16B: Fire Safety Information
Revisions to Part B: Fire Safety
Revised wording to B3
The Building and Approved Inspectors (Amendment) (No. 2) Regulations 2006
![Page 4: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/4.jpg)
Changes to Part B (Fire Safety) of the Building Regulations and Approved Document B
Volume 1 - Dwellinghouses
Volume 2 – Buildings Other Than Dwellinghouses
Flats (including multi-storey flats & mixed-use buildings) can be found in Volume 2
![Page 5: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/5.jpg)
Procedural Changes
Amended requirement B3(3) – part of internal fire spread (structure)
![Page 6: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/6.jpg)
Procedural Changes
![Page 7: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/7.jpg)
• Building Control are still responsible for checking compliance of building work
• Fire Safety Authority are responsible for enforcing the fire safety order once the building is occupied, previously the Fire Precautions Act and the Workplace Regulations
• Will be amended again to incorporate Part B changes
Procedural Changes
![Page 8: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/8.jpg)
" Fire safety information 16B. —(1) This regulation applies where building work—
(a) consists of or includes the erection or extension of a relevant building; or
(b) is carried out in connection with a relevant change of use of a building,
and Part B of Schedule 1 imposes a requirement in relation to the work.
(2) The person carrying out the work shall give fire safety information to the responsible person not later than the date of completion of the work, or the date of occupation of the building or extension, whichever is the earlier.
(3) In this regulation—
(a) "fire safety information" means information relating to the design and construction of the building or extension, and the services, fittings and equipment provided in or in connection with the building or extension which will assist the responsible person to operate and maintain the building or extension with reasonable safety;
(b) a "relevant building" is a building to which the Regulatory Reform (Fire Safety) Order 2005 applies[4], or will apply after the completion of building work;
(c) a "relevant change of use" is a material change of use where, after the change of use takes place, the Regulatory Reform (Fire Safety) Order 2005 will apply, or continue to apply, to the building; and
(d) "responsible person" has the meaning given by article 3 of the Regulatory Reform (Fire Safety) Order 2005."
![Page 9: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/9.jpg)
Procedural Changes
![Page 10: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/10.jpg)
Meaning of "responsible person"
3. In this Order "responsible person" means—
(a) in relation to a workplace, the employer, if the workplace is to any extent under his control;
(b) in relation to any premises not falling within paragraph (a)—
(i) the person who has control of the premises (as occupier or otherwise) in connection with the carrying on by him of a trade, business or other undertaking (for profit or not); or
(ii) the owner, where the person in control of the premises does not have control in connection with the carrying on by that person of a trade, business or other undertaking.
STATUTORY INSTRUMENTS
2005 No. 1541
REGULATORY REFORM, ENGLAND AND WALES
The Regulatory Reform (Fire Safety) Order 2005
Regulatory Reform (Fire Safety) Order 2005
![Page 11: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/11.jpg)
Application to premises 6. — (1) This Order does not apply in relation to —
(a) domestic premises, except to the extent mentioned in article 31(10);
(b) an offshore installation within the meaning of regulation 3 of the Offshore Installation and Pipeline Works (Management and Administration) Regulations 1995[13];
(c) a ship, in respect of the normal ship-board activities of a ship's crew which are carried out solely by the crew under the direction of the master;
(d) fields, woods or other land forming part of an agricultural or forestry undertaking but which is not inside a building and is situated away from the undertaking's main buildings;
(e) an aircraft, locomotive or rolling stock, trailer or semi-trailer used as a means of transport or a vehicle for which a licence is in force under the Vehicle Excise and Registration Act 1994[14] or a vehicle exempted from duty under that Act;
(f) a mine within the meaning of section 180 of the Mines and Quarries Act 1954[15], other than any building on the surface at a mine;
(g) a borehole site to which the Borehole Sites and Operations Regulations 1995[16] apply.
(2) Subject to the preceding paragraph of this article, this Order applies in relation to any premises
Regulatory Reform (Fire Safety) Order 2005
![Page 12: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/12.jpg)
PART 2FIRE SAFETY DUTIES
Duty to take general fire precautions 8. —(1) The responsible person must—(a) take such general fire precautions as will ensure, so far as is reasonably practicable, the safety of any of his employees; and
(b) in relation to relevant persons who are not his employees, take such general fire precautions as may reasonably be required in the circumstances of the case to ensure that the premises are safe.
Risk assessment 9. —(1) The responsible person must make a suitable and sufficient assessment of the risks to which relevant persons are exposed for the purpose of identifying the general fire precautions he needs to take to comply with the requirements and prohibitions imposed on him by or under this Order.
Regulatory Reform (Fire Safety) Order 2005
![Page 13: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/13.jpg)
Duty to consult enforcing authority before passing plans 45. —(1) Where it is proposed to erect a building, or to make any extension of or structural alteration to a building and, in connection with the proposals, plans are, in accordance with building regulations, deposited with a local authority, the local authority must, subject to paragraph (3), consult the enforcing authority before passing those plans.
(2) Where it is proposed to change the use to which a building or part of a building is put and, in connection with that proposal, plans are, in accordance with building regulations, deposited with a local authority, the authority must, subject to paragraph (3), consult with the enforcing authority before passing the plans.
(3) The duty to consult imposed by paragraphs (1) and (2)—
(a) only applies in relation to buildings or parts of buildings to which this Order applies, or would apply following the erection, extension, structural alteration or change of use;
(b) does not apply where the local authority is also the enforcing authority.
Regulatory Reform (Fire Safety) Order 2005
Duty to Consult
![Page 14: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/14.jpg)
Procedural Changes
![Page 15: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/15.jpg)
Volume One
Dwellinghouses
![Page 16: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/16.jpg)
New Diagram 1 illustrates basic principles
![Page 17: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/17.jpg)
Direct reference to BS 5839-6: 2004Grade D = mains powered with standby supplyLD3 = Detectors in circulation spaces
ExtensionsProvide smoke alarms where habitable rooms are provided above ground level or if at ground level where there is no final exit from the new room
Smoke & Heat Alarms
![Page 18: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/18.jpg)
New guidance on the use of domestic sprinklers as a compensatory feature.
Specific alternative approaches in paragraphs:
B1 – 2.7 houses with more than one floor over 4.5m above ground level
B1 – 2.20b Loft conversions
B4 – 9.15 Space separation
Domestic Sprinklers
![Page 19: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/19.jpg)
Not required in houses with a floor more than 4.5m above ground level.
Locks (with or without removable keys) and stays may be fitted to egress windows, subject to the stay being fitted with a release catch, which may be child reistant
Egress Windows
![Page 20: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/20.jpg)
Escape provision to be no worse than the window it replaces: except-
If original window is larger than necessary, opening can be reduced to minimum dimensions specified.
Replacement Windows
![Page 21: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/21.jpg)
Fire Doors
Self Closing Devices
Self-closing devices not required on fire doors within dwellings.
Except
Doors to integral garages
Flat entrance doors (vol. 2)
Fire Doors ARE still necessary
![Page 22: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/22.jpg)
Alternative approach DELETED
Provide protected stairs & smoke alarms
Some existing doors could be upgraded
Alternative approach for open plan ground floor –
Cut off door, escape window and sprinkler protection
Loft Conversions
![Page 23: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/23.jpg)
Galleries
Alternative exit/escape window
OR
Overlook 50% of the room below
• 7.5m max travel to head of stair
• 3m max travel from foot of stair
• cooking facilities remote or enclosed
Also applies to flats
Galleries
![Page 24: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/24.jpg)
Integral Garages
• Compartment wall & floor
• Sloping floor OR 100mm step
See also
• Item 8 Table A1 – REI 30
• Item 2 Table 3 – soil pipes
• Item 1b Table B1 – E30 Sa Door
![Page 25: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/25.jpg)
Diagram 11 Junction of Compartment Wall with Roof
![Page 26: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/26.jpg)
“New” European roof test
Constructions are classified within the BS EN 13501-5:2005 as
BROOF(t4), CROOF(t4),
DROOF(t4), EROOF(t4) or
FROOF(t4)
BROOF(t4) being the highest
performance and FROOF(t4)
being the lowest
(t4) indicates test 4 from the
soon to be BS EN 1187
Roof Coverings (Vol 1& 2)
![Page 27: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/27.jpg)
Volume Two
Buildings Other Than Dwellinghouses
![Page 28: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/28.jpg)
New guidance on the use of domestic sprinklers as a compensatory feature.
Specific alternative approaches in paragraphs:
B1 – 2.7 houses with more than one floor over 4.5m above ground level
B4 – 9.15 Space separation
Flats
Domestic Sprinkler Protection for Flats
Sprinklers to be provided within individual flats in blocks over 30m in height. Limitation of BS 9251 clarified height restriction to under 20m in height can be ignored.
![Page 29: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/29.jpg)
Smoke Control of Common Escape Route in Flats
There should be some means of ventilating common corridors/ lobbies to control smoke and so protect common stairs
This offers individual protection to that provided by the fire doors to the stair
• single stair buildings – AOV
• Multi stair buildings – OV•Guidance on the design of smoke control systems using pressure differentials is available in BS EN 12101-6:2005.
![Page 30: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/30.jpg)
Flats
![Page 31: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/31.jpg)
Guidance from BS 5588 incorporated into main text
Moving back from having to purchase additional documents!
Small Premises
![Page 32: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/32.jpg)
Open Spatial Planning
![Page 33: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/33.jpg)
Self Storage Buildings
![Page 34: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/34.jpg)
Care Homes
![Page 35: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/35.jpg)
Inclusive Design
![Page 36: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/36.jpg)
Refuges
![Page 37: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/37.jpg)
Compartmentation
![Page 38: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/38.jpg)
Phased Evacuation
![Page 39: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/39.jpg)
Compartment Walls/ Floors Junction
![Page 40: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/40.jpg)
Guidance reworked for clarity
Barriers in under floor voids
Aluminium and uPVC windows not suitable for closing cavities
Cavity Barriers
![Page 41: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/41.jpg)
Notional Boundaries
![Page 42: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/42.jpg)
Car Parks
![Page 43: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/43.jpg)
External Walls
![Page 44: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/44.jpg)
Vehicle access for pump appliance within 45m of “all points”to blocks of flats
Or: provide fire mains (not in f/f shaft)
Fire mains
New standard BS 9990
Wet mains required for buildings over 50m
Dry mains
Access for pump within 18m
Fire Service Access
![Page 45: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/45.jpg)
Fire Fighting Shafts/ Fire Mains
![Page 46: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/46.jpg)
Private Fire Hydrants
![Page 47: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/47.jpg)
Door Measurement
![Page 48: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/48.jpg)
Smoke Ventilators
![Page 49: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/49.jpg)
Transitional Provisions
![Page 50: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/50.jpg)
Fire Safety Risk Assessment Documents
![Page 51: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/51.jpg)
www.communities.gov.uk
![Page 52: Fire Safety Presentation on Building Regulations Part B 2007](https://reader036.vdocuments.us/reader036/viewer/2022081508/55626a51d8b42ae87d8b5416/html5/thumbnails/52.jpg)
Changes to Oil Fired Boiler Requirements From the 1st April 2007 the energy performance standard of new and replacement Oil fired central heating boilers. From that date, in normal circumstances when you plan to install a new boiler or replace an existing one, you will need a condensing boiler to meet the higher standards for energy efficiency. This follows on from Gas fired central heating boilers, which have had to comply since 1st April 2005.
For boilers installed on or after the 1st April 2007:
The boiler should be a condensing type; and
The boiler efficiency should not be less than 86% (as expressed by its SEDBUK value)
Further information is available in the 2nd tier document ‘Domestic Heating Compliance Guide’ which can be viewed at www.planningportal.gov.uk