Enhanced Smoke Detection System with
EMERGENCY LIGHTSand
REMOTE MESSAGING SYSTEM
![Page 2: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/2.jpg)
Submitted By:
09061720906175090618209061840906187
![Page 3: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/3.jpg)
Objective
how c
an w
e
STOP
thes
e?
![Page 4: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/4.jpg)
Reasons of Major Losses
• Lower quality of Fire Detection System• Communication gap among the buildings and Nearest Fire
Service Stations• Lack of Fire Extinguishers• Absence of Emergency Systems
![Page 5: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/5.jpg)
Project Overview:
• A remote SMS system to communicate immediately with nearest fire stations, local PS, local hospitals and other necessary places
• A emergency light system in case of power failure
![Page 6: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/6.jpg)
Required chips
• ATMEGA32A• LM35 (Heat Sensor)• LM324 (Op-Amp)• 7404 (Not Gate)• SIM900 (GSM Module)
![Page 7: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/7.jpg)
Block Diagram (Emergency Light)
Main Line
220-6V XFR
Charge/Discharge
DC Battery
Emergency Light
![Page 8: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/8.jpg)
Block Diagram (Remote SMS)
5V Vcc
LM35 (Heat Sensor)
Voltage Comparator
ATMEGA32A
GSM Module
![Page 9: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/9.jpg)
Circuit Diagram
![Page 10: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/10.jpg)
Remote SMS System
• The GSM module (SIM 900) is interfaced with ATMEGA32A in the total system
![Page 11: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/11.jpg)
Sensing The Fire
• A heat sensor (LM35) is used to detect room temperature• A comparator circuit is used to compare the output voltage of
LM35 with a given reference voltage• If the output is above certain level, it takes the decision that a fire
incident has occurred
![Page 12: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/12.jpg)
SOS
As the fire has been detected, the module will automatically send SMS to necessary persons and places
![Page 13: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/13.jpg)
Emergency Light System
Smok
e
Shor
t Circ
uit
Sabo
tage
Faulte
d Equ
ipm
ent
Faulte
d Pr
oduc
iton
Flam
able
Raw
Mat
teria
ls
Misce
llane
ous
0
10
20
30
40
Series 1
Column2 Series 1Column1Column2
![Page 14: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/14.jpg)
Emergency Light System
• Powered by a rechargeable DC battery• If the main power goes off, the emergency lights
automatically turn on• Other times, the battery is being charged and kept nearly
100% charged
![Page 15: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/15.jpg)
Cost Estimation
• GSM Module- Tk. 2300• Transformer (220-6V)- Tk. 65• Microchip (ATMEGA32A)- Tk. 200• Heat Sensor (LM35)- Tk. 45• DC Battery (2 pcs)- Tk.50• Miscellaneous- Tk. 130
• Total Cost- Tk. 2790
In case of MASS PRODUCTION, total cost can be decreased to Tk. 2000 (estimated)
![Page 16: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/16.jpg)
Limitations
• LM35 is very sensitive, so in case of other temperature arising incidents, the system can turn on.
• The output of LM35 is in mV range (10 mV/◦C), so minor noise can activate the system
![Page 17: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/17.jpg)
Future Development
• Inclusion of fire alarm• Automated Fire Extinguishers in sensitive places
![Page 18: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/18.jpg)
Cautions
• Both GSM Module and Microchips are voltage sensitive, minimum increase can harm these devices
• GSM module is temperature sensitive• Total system (except the LM35) should be installed in a
neutral place
![Page 19: Fire protection system](https://reader035.vdocuments.us/reader035/viewer/2022062308/55c14201bb61ebc37c8b45c2/html5/thumbnails/19.jpg)
Thank you
Save life, save property, get your own device now