FEEDER PROTECTION RELAY ADR245B
![Page 2: FEEDER PROTECTION RELAY](https://reader033.vdocuments.us/reader033/viewer/2022061508/58a8677f1a28ab6c328b6be5/html5/thumbnails/2.jpg)
BASIC VERSION (ADR245B)
![Page 3: FEEDER PROTECTION RELAY](https://reader033.vdocuments.us/reader033/viewer/2022061508/58a8677f1a28ab6c328b6be5/html5/thumbnails/3.jpg)
ENHANCED VERSION (ADR245B)
![Page 4: FEEDER PROTECTION RELAY](https://reader033.vdocuments.us/reader033/viewer/2022061508/58a8677f1a28ab6c328b6be5/html5/thumbnails/4.jpg)
MODULAR VERSION (ADR245B)
![Page 5: FEEDER PROTECTION RELAY](https://reader033.vdocuments.us/reader033/viewer/2022061508/58a8677f1a28ab6c328b6be5/html5/thumbnails/5.jpg)
Functional Overview: Key Protection & Control Functions:
• Two Independent Settings Groups
• Directional / Non Directional Phase & Ground Over Current Function
(50/51/51N/51N/51V/67/67N)
• Four Independent Stages for Directional/Non Directional Phase Over
Current Protection
• Three Stages of Directional/Non Directional Ground Over Current
Protection
• Internally Derived / Externally measured Ground Over Current (3I0>)
Protection
![Page 6: FEEDER PROTECTION RELAY](https://reader033.vdocuments.us/reader033/viewer/2022061508/58a8677f1a28ab6c328b6be5/html5/thumbnails/6.jpg)
Functional Overview: Key Protection & Control Functions:
• Inverse Time Over Current Protection (IEC curves according to IEC60255)
• High Impedance Restricted Earth Fault Protection (64G)
• Inverse & Definite Time Negative Phase Sequence Over Current Protection
(46)
• Broken Conductor Protection (46BC)
• Negative Phase Sequence Over Voltage Protection (47) • Under and Over Voltage Protection (27/59) • Externally Measured / Internally Calculated Residual Over Voltage
Protection (59N)
![Page 7: FEEDER PROTECTION RELAY](https://reader033.vdocuments.us/reader033/viewer/2022061508/58a8677f1a28ab6c328b6be5/html5/thumbnails/7.jpg)
Functional Overview: Key Protection & Control Functions:
• Multi Shots (4-shots) Auto-Reclosing function (79)
• Breaker Failure Detection (50BF)
• VT and CT Supervision Function
• Trip Circuit Supervision Function (74T)
• Programmable Inputs & Outputs (12 DI/ 11 DO)
• CB Close / Trip from HMI
• Directional Power Protection (32) available in Enhance/Modular version
• Frequency Protection (81U/O) available in Enhance/Modular version
![Page 8: FEEDER PROTECTION RELAY](https://reader033.vdocuments.us/reader033/viewer/2022061508/58a8677f1a28ab6c328b6be5/html5/thumbnails/8.jpg)
Functional Overview: Key Protection & Control Functions:
• Programmable & Target LEDs for indication with dual colours
• Self Supervision of Relay
• Metering Function
• Disturbance Recording (10 nos.)
• Event Recording
• Fault Recording on HMI display (10nos.)
• Non-Volatile memory
• Fully communicable with IEC standard open protocol IEC60870-5-103,
MODBUS & IEC 61850.
![Page 9: FEEDER PROTECTION RELAY](https://reader033.vdocuments.us/reader033/viewer/2022061508/58a8677f1a28ab6c328b6be5/html5/thumbnails/9.jpg)
Functional Overview: Key Protection & Control Functions:
• SCADA communication
• PC front port communication for convenient relay settings
• User friendly local operation with key pad
• Large Liquid crystal display (20X4) with backlight
• Password Protection
![Page 10: FEEDER PROTECTION RELAY](https://reader033.vdocuments.us/reader033/viewer/2022061508/58a8677f1a28ab6c328b6be5/html5/thumbnails/10.jpg)
Functional Overview: Key Protection & Control Functions: