Transcript

Exceptional quality. Unique design

ACN: 111 343 312 ABN: 52 111 343 312

Email:[email protected]

Mob:0423888213

InstallationofTama,Lennox,DocklandsorBelongilfreestandingshowertoconcrete.

Inallcases,finalwaterconnectionsaremadeinthegroundaftertheshowerhasbeenfixedintoplace.

Theinstallerwillneedtosupplythefollowing:

Installationmustbecarriedoutbyalicensedplumber

4x125mmlengthsof10mmStainlessSteelthreadedrod

12x10mmstainlesssteelnutsandwashers.

Chemsetadhesiveorequivalent.

Forfixingtoaconcreteslabthatisgoingtobetiled,THESHOWERMUSTBEINSTALLEDANDCONNECTEDTOWATERSUPPLYBEFORETILING.

Installationstepsforfixingtoconcrete.Refertoimageswhererequired.Minimumsizedconcretepadis500mmx500mmx100mmthick.

1. Usinganormalthreadsealingtapeorcompound,screwthestainlesssteelplateontothebottomoftheshower,asfarasitwillgo.Thereshouldbenoplayormovementwhatsoeverbetweenthetwothreads.DoNOTcutthebottomofthebrassthreadafterthebaseplateisscrewedon.Theinternalthreadonthebaseplateissharpandglovesshouldbeusedforhandling.

2. Placetheshowerinpositionontheconcrete,withtheshowerarmfacingtherequireddirection.Intermsofdepth,youwillrequire60mmbelowtheundersideoftile(oranyotherfinishingmaterialforthesurroundingground)toensurethebaseplateoftheshoweriscompletelyconcealed.Ifaloosesubstrate,suchaspebblesisbeingusedforthesurroundingground,ensurethebaseplateandbrassthreadarelowenoughtobeconcealedbythefinishingmaterial.Ineithercase,itmaybenecessarytoremove(orchase)theconcrete.

3. Withtheshowerorientedintherequireddirection,marktheoutsideholesonthestainlesssteelbaseplateontheconcreteanddrill12mmholestoadepthof50-60mm.

4. Attachthe4piecesofthreadedrodtothebaseplateusingnutsandwashersasiftheyarethefourlegsofatable(Fig2),withthemaximumamountofrodprotrudingbelowthebaseplate.

5. Withoutusingadhesive,placetheshower,withthefourpiecesofthreadedrodintheirrespectiveholesintheconcrete.Settheheightofthebaseplate(usingthenutsandwashers)sothattheshowerislevelandthereisaminimumof30mmbetweentheconcreteandtheundersideofthestainlesssteel.

Exceptional quality. Unique design

ACN: 111 343 312 ABN: 52 111 343 312

6. Removetheshowerandbaseplatefromtheholesandusingtwo15mmcopperelbows,extendthehotandcoldshowerpipes,suchthattheystickouthorizontallyfromtheundersideofthestainlesssteelbaseplate(Fig1.).Thesetwopipesshouldbeatleast200mmproudofthebaseplate.

7. andwhentheshowerisinposition,willendupbeinghorizontalandpositionedbetweentheconcreteandtheundersideofthestainlesssteel.

8. Usingconstructionadhesive,fixtheshowerintothe12mmholesaspertheinstructionsfortheadhesive(Chemsetorequivalentrecommended).Oncetheadhesivehascured,leveltheshowerwiththenutsandwashersandmakefinalplumbingconnectionstothesitehotandcoldwatersupply.Testallconnectionsbeforefinishingtradescommence.Thevoidontheundersideofthebaseplatecanbegroutedifpreferred.

Fig2.

Fig1

Exceptional quality. Unique design

ACN: 111 343 312 ABN: 52 111 343 312

InstallationofTama,Lennox,DocklandsorBelongilfreestandingshowertotimberdeck.

Installationmustbecarriedoutbyalicensedplumber.

Theinstallerwillneedtosupplythefollowing:

4x125mmlengthsof10mmStainlessSteelthreadedrod

16x10mmstainlesssteelnutsandwashers.

Installationstepsforfixingtotimberdeck.

1. Usinganormalthreadsealingtapeorcompound,screwthestainlesssteelplateontothebottomoftheshower,asfarasitwillgo.Thereshouldbenoplayormovementwhatsoeverbetweenthetwothreads.DoNOTcutthebottomofthebrassthreadafterthebaseplateisscrewedon.Theinternalthreadonthebaseplateissharpandglovesshouldbeusedforhandling.

2. Placetheshowerinpositiononthedeck.Whenlocatingtheshower,bearinmindthefollowing:Thebaseofthe65mmpipeshouldbeovertwodeckingboardssuchthatthe75mmholefortheshowerpipeiscutacrosstwodeckingboards.Whenrefittingthedeckingboardsaftertheshowerisinplace,thiswillallowaboardtobeslidinoneachsideoftheshower.Enoughclearancefromtimberjoistsisalsorequiredforthe200mmbaseplate,underthedeck.

3. Installsufficienttimberblockingbetweenthetwojoistsatthelocationoftheshower,tosupporttheshowerwithoutanymovement.Thisblockingshouldbeaminimumof60mmbelowtheundersideofthedeckingboards.

4. Withtheshowerinpositionandorientedintherequireddirection,marktheoutsideholesonthestainlesssteelbaseplateonthetimberblockinganddrill12mmholesallthewaythroughtheblocking

5. Attachthe4piecesofthreadedrodtothebaseplateusingnutsandwashersasiftheyarethefourlegsofatable,withthemaximumamountofrodprotrudingbelowthebaseplate(Fig2).Twonutsandtwowashersarerequiredforeachthreadontheundersideofthebaseplate.Thisistosupportthebaseplateapprox.35mmabovethetimberblock.

6. Placetheshower,withthefourpiecesofthreadedrodintheirrespectiveholesinthetimber.Settheheightofthebaseplate(usingthenutsandwashers)sothattheshowerislevelandthereisaminimumof30mmbetweenthetimberblockingandtheundersideofthestainlesssteel.

7. Removetheshowerandbaseplatefromtheholesandusingtwo15mmcopperelbows,extendthehotandcoldshowerpipes,suchthattheystickouthorizontallyfromtheundersideofthestainlesssteelbaseplate(Fig1.).Thesetwopipesshouldbeatleast200mmproudofthebaseplateandwhentheshowerisinposition,willendupbeinghorizontalandpositionedbetweentheconcreteandtheundersideofthestainlesssteel.

Exceptional quality. Unique design

ACN: 111 343 312 ABN: 52 111 343 312

8. Bolttheshowerintoposition,usingnutsandwashersontheundersideofthetimberblock.Leveltheshowerwiththenutsandwashersbetweenthebaseplateandthetimberblockandmakefinalplumbingconnectionstothesitehotandcoldwatersupply.Testallconnectionsbeforefinishingtradescommence.Thevoidontheundersideofthebaseplatecanbefilledifpreferred.Alternativemethodfortimberdeckfixing.Ifthereisenoughspacebelowthedecktomakeallplumbingconnectionsunderthetimberblocksupportingtheshower,a90mmholecanbedrilledinthetimberblocktoallowthehotandcoldpipestopassthroughthetimber.Thebaseplatecanthenbebolteddirectlytothetimberblockingandthefinalconnectionsmadeunderneaththetimber.

InstallationofTama,Lennox,DocklandsorBelongilshowerasawallmountedunit.Installationmustbecarriedoutbyalicensedplumber.Theseinstructionsareapplicablewherethehotandcoldwaterpipesexittheshoweratthebase.Pleasecontactusdirectlyiftheshoweryouareinstallinghasbeencustomisedsuchthatthewaterconnectionsareaboveground,attherearofthemain65mmpipe.Installerwillneedtosupplyconstructionadhesive(Chemsetorequivalentrecommended)Theshowermustbefixedtothewallandconnectedbeforefinalfinishesareinstalledonthegroundsurroundingthebaseoftheshower.1. Markfinishedgroundlevelonthewallattheshowerlocation.2. Positiontheshowersotheendsofthetwo20mmcopperspigotsattherearareresting

againstthewallandthebaseofthemain65mmpipeis5-10mmaboveFFL.3. Markthepositionofthespigotswiththeshowerpositionedlevelandplumb.The

spigotsshouldbeaminimum70mmlongandengagedintheholesinthewallaminimumof50mm.Spigotscanbeshortenedifrequired

4. Drill21mmholesaminimumof50mmdeepatthelocationofthespigots.5. Testthatthespigotsslideintotheholesreasonablyeasily.Adjustsizeofholesslightly,if

necessary.6. Blowalldustoutofdrillholesandfilltheholeswithadhesiveto15mmshortoftheface

ofthewall.7. Slidethespigotsintotheholestothepointatwhichthemain65mmpipeis20-25mm

awayfromthewall.Allowadhesivetocure.8. Makefinalconnectionstositewatersupplyandinstallshowerrose.

Exceptional quality. Unique design

ACN: 111 343 312 ABN: 52 111 343 312


Top Related