1.End tidal carbon dioxide analysis
2.Transcutaneous and carbon dioxide monitors
![Page 2: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/2.jpg)
Introduction
• Capnometry refers to the measurement and quantification of inhaled or exhaled CO2
concentrations at the airway opening.
• Capnography, however, refers not only to the method of CO2 measurement, but also to its graphic display as a function of time or volume.
![Page 3: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/3.jpg)
PHYSIOLOGY OF CAPNOMETRY
![Page 4: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/4.jpg)
Oxygenation and Ventilation
Oxygenation
(oximetry)
Cellular
Metabolism
Ventilation
(capnography)
CO2
O2
![Page 5: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/5.jpg)
Oxygenation and Ventilation
• Oxygenation
– Oxygen for metabolism
– SpO2 measures % of O2 in RBC
– Reflects change in oxygenation within 5 minutes
• Ventilation
– Carbon dioxide from metabolism
– EtCO2 measures exhaled CO2 at point of exit
– Reflects change in ventilation within 10 seconds
![Page 6: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/6.jpg)
CO2 transport
![Page 7: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/7.jpg)
End-tidal CO2 (EtCO2)
• Reflects changes in
– Ventilation - movement of air in and out of the lungs
– Diffusion - exchange of gases between the air-filled alveoli and the pulmonary circulation
– Perfusion - circulation of blood
![Page 8: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/8.jpg)
End-tidal CO2 (EtCO2)
r r Oxygen
O
2CO2
O
2
VeinA te y
Ventilation
Perfusion
Pulmonary Blood Flow
Right
Ventricle
Left
Atrium
![Page 9: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/9.jpg)
End-tidal CO2 (EtCO2)
• Monitors changes in – Ventilation - asthma, COPD, airway
edema, foreign body, stroke
– Diffusion - pulmonary edema, alveolar damage, CO poisoning, smoke inhalation
– Perfusion - shock, pulmonary embolus, cardiac arrest, severe dysrhythmias
![Page 10: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/10.jpg)
![Page 11: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/11.jpg)
PRINCIPLES OF CAPNOGRAPHY
![Page 12: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/12.jpg)
BEER-LAMBERT LAW
![Page 13: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/13.jpg)
Types of sensors
Solid state CO2 sensors
Chopper wheel CO2 sensor
![Page 14: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/14.jpg)
Sidestream vs Mainstream Capnometry
Sidestream/ Diverging• CO2 sensor located away from the
airway gases to be measured.• Incorporate a pump or
compressor.• Tubing length- 6 ft• Gas withdrawal rate 30-
500ml/min• Lost gas volume needs to be
considered in closed circuit anesthesia.
• Gases must pass through various water traps and filters.
• Transport delay time• Associated RISE TIME
Mainstream/ Non- diverting• Sample cell placed directly in the
patients breathing circuit.
• Inspiratory and expiratory gases pass directly through the IR path
• Increase in dead space and is heavy
• Sample cell heated to 40 degrees to minimize condensation.
• Increased risk of facial burns.
• Requires daily calibration.
• No delay time
• RISE TIME is faster
![Page 15: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/15.jpg)
Types of capnometers
![Page 16: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/16.jpg)
CAPNOGRAPHY WAVEFORMS
Interpretation of TIME
![Page 17: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/17.jpg)
Capnographic Waveform
• Normal waveform of one respiratory cycle
• Similar to ECG
– Height shows amount of CO2
– Length depicts time
![Page 18: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/18.jpg)
Capnographic Waveform
• Waveforms on screen and printout may differ in duration
– On-screen capnography waveform is condensed to provide adequate information the in 4-second view.
![Page 19: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/19.jpg)
Capnographic Waveform
• Capnograph detects only CO2
from ventilation
• No CO2 present during inspiration
– Baseline is normally zero
A B
C D
E
Baseline
![Page 20: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/20.jpg)
Capnogram Phase IDead Space Ventilation
• Beginning of exhalation
• No CO2 present
• Air from trachea, posterior pharynx, mouth and nose
– No gas exchange occurs there
– Called “dead space”
![Page 21: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/21.jpg)
Deadspace
![Page 22: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/22.jpg)
Capnogram Phase I Baseline
Beginning of exhalation
AB
IBaseline
![Page 23: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/23.jpg)
Capnogram Phase IIAscending Phase
• CO2 from the alveoli begins to reach the upper airway and mix with the dead space air – Causes a rapid rise in the
amount of CO2
• CO2 now present and detected in exhaled air
Alveoli
![Page 24: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/24.jpg)
Capnogram Phase IIAscending Phase
CO2 present and increasing in exhaled air
II
A B
C
Ascending Phase
Early Exhalation
![Page 25: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/25.jpg)
Capnogram Phase IIIAlveolar Plateau
• CO2 rich alveolar gas now constitutes the majority of the exhaled air
• Uniform concentration of CO2 from alveoli to nose/mouth
![Page 26: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/26.jpg)
Capnogram Phase IIIAlveolar Plateau
CO2 exhalation wave plateaus
A B
C D
III
Alveolar Plateau
![Page 27: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/27.jpg)
Capnogram Phase IIIEnd-Tidal
• End of exhalation contains the highest concentration of CO2
– The “end-tidal CO2”
– The number seen on your monitor
• Normal EtCO2 is 35-45mmHg
![Page 28: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/28.jpg)
Capnogram Phase IIIEnd-Tidal
End of the the wave of exhalation
A B
C D End-tidal
![Page 29: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/29.jpg)
Capnogram Phase IVDescending Phase
• Inhalation begins
• Oxygen fills airway
• CO2 level quickly drops to zero
Alveoli
![Page 30: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/30.jpg)
Capnogram Phase IVDescending Phase
Inspiratory downstroke returns to baseline
A B
C D
EIV
Descending Phase
Inhalation
![Page 31: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/31.jpg)
Capnography Waveform
Normal range is 35-45mm Hg (5% vol)
Normal Waveform
45
0
![Page 32: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/32.jpg)
a-A Gradient
r r Alveolus
PaCO2
VeinA te y
Ventilation
Perfusion
arterial to Alveolar Difference for CO2
Right
Ventricle
Left
Atrium
EtCO2
![Page 33: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/33.jpg)
![Page 34: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/34.jpg)
![Page 35: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/35.jpg)
End-tidal CO2 (EtCO2)
• Normal a-A gradient
– 2-5mmHg difference between the EtCO2
and PaCO2 in a patient with healthy lungs
![Page 36: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/36.jpg)
Factors Affecting ETCO2 Levels
![Page 37: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/37.jpg)
45
0
Hyperventilation
RR : EtCO2
45
0
Normal
Hyperventilation
![Page 38: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/38.jpg)
Waveform: Regular Shape, Plateau Below Normal
• Indicates CO2 deficiency
Hyperventilation
Decreased pulmonary perfusion
Hypothermia
Decreased metabolism
• Interventions
Adjust ventilation rate
Evaluate for adequate sedation
Evaluate anxiety
Conserve body heat
![Page 39: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/39.jpg)
Hypoventilation
45
0
45
0
RR : EtCO2
Normal
Hypoventilation
![Page 40: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/40.jpg)
Waveform: Regular Shape, Plateau Above Normal
• Indicates increase in ETCO2
Hypoventilation
Respiratory depressant drugs
Increased metabolism
• Interventions
Adjust ventilation rate
Decrease respiratory depressant drug dosages
Maintain normal body temperature
![Page 41: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/41.jpg)
Bronchospasm Waveform Pattern
• Bronchospasm hampers ventilation– Alveoli unevenly filled on inspiration – Empty asynchronously during expiration– Asynchronous air flow on exhalation dilutes exhaled
CO2
• Alters the ascending phase and plateau– Slower rise in CO2 concentration – Characteristic pattern for bronchospasm– “Shark Fin” shape to waveform
![Page 42: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/42.jpg)
Capnography Waveform Patterns
45
0
Normal
Bronchospasm
45
0
![Page 43: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/43.jpg)
Capnography Waveform Patterns
45
0
Hypoventilation
Normal
45
0
45
0
Bronchospasm
Hyperventilation
45
0
![Page 44: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/44.jpg)
Airway obstruction Cardiogenic oscillations
Curare Cleft Esophageal Intubation
![Page 45: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/45.jpg)
Rebreathing of CO2 Faulty inspiratory valve
Patient with single lung transplant Faulty inspiratory valve
![Page 46: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/46.jpg)
Ruptured/ Leaking ET tube cuff Leak in side stream sample line
Expiratory valve stuck open
Electrical Noise
![Page 47: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/47.jpg)
![Page 48: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/48.jpg)
![Page 49: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/49.jpg)
![Page 50: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/50.jpg)
VOLUME CAPNOGRAM
![Page 51: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/51.jpg)
Volume Capnogram
![Page 52: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/52.jpg)
Acute Bronchospasm
Changes in pulmonary perfusion
![Page 53: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/53.jpg)
Advantages of volume capnogram
• Allows for estimation of the relative contributions of anatomic and alveolar components of Vd.
• More sensitive than the time capnogram in detecting subtle changes in dead space that are caused by alterations in PEEP, pulmonary blood flow, or ventilation heterogeneity.
• Allows for determination of the total mass of CO2 exhaled during a breath and provides for estimation of V˙ CO2.
![Page 54: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/54.jpg)
USES OF CAPNOGRAPHY
![Page 55: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/55.jpg)
Detect ET Tube Displacement
Confirm ET Tube Placement
![Page 56: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/56.jpg)
Capnography in Cardiopulmonary Resuscitation
• Assess chest compressions
• Early detection of ROSC
• Objective data for decision to cease resuscitation
• Use feedback from EtCO2 to depth/rate/force of chest compressions during CPR.
![Page 57: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/57.jpg)
In Laparoscopic Surgeries
1.Non invasive monitor of PaCO2 and can be used to adjust ventilation.2.Detection of accidental intravascular CO2 insufflation.3.Helps to detect complications of CO2 insufflation like pneumothorax.
![Page 58: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/58.jpg)
Optimize Ventilation
• Use capnography to titrate EtCO2 levels in patients sensitive to fluctuations
• Patients with suspected increased intracranial pressure (ICP)
– Head trauma
– Stroke
– Brain tumors
– Brain infections
![Page 59: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/59.jpg)
Optimize Ventilation
• High CO2 levels induce cerebral vasodilatation– Positive: Increases CBF to
counter cerebral hypoxia
– Negative: Increased CBF, increases ICP and may increase brain edema
• Hypoventilation retains CO2
which increases levels
CO2
![Page 60: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/60.jpg)
Optimize Ventilation
• Low CO2 levels lead to cerebral vasoconstriction– Positive: EtCO2 of 25-30mmHG causes a
mild cerebral vasoconstriction which may decrease ICP
– Negative: Decreased ICP but may cause or increase in cerebral hypoxia
• Hyperventilation decreases CO2 levels CO2
![Page 61: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/61.jpg)
The Non-intubated Patient Capnography Applications
• Identify and monitor bronchospasm
– Asthma
– COPD
• Assess and monitor
– Hypoventilation states
– Hyperventilation
– Low-perfusion states
![Page 62: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/62.jpg)
Capnography in Bronchospastic Conditions
• Air trapped due to irregularities in airways
• Uneven emptying of alveolar gas
– Dilutes exhaled CO2
– Slower rise in CO2 concentration during exhalation
Alveoli
![Page 63: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/63.jpg)
Capnography in Bronchospastic Diseases
• Uneven emptying of alveolar gas alters emptying on exhalation
• Produces changes in ascending phase (II) with loss of the sharp upslope
• Alters alveolar plateau (III) producing a “shark fin”
A B
C D
EII
III
![Page 64: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/64.jpg)
Capnography in Bronchospastic Conditions
AsthmaCase
Initial
After therapy
![Page 65: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/65.jpg)
Capnography in Bronchospastic Conditions
Pathology of COPD
• Progressive
• Partially reversible
• Airways obstructed
– Hyperplasia of mucous glands & smooth muscle
– Excess mucous production
– Some hyper-responsiveness
![Page 66: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/66.jpg)
Capnography in Bronchospastic Conditions
Capnography in COPD
• Arterial CO2 in COPD
– PaCO2 increases as disease progresses
– Requires frequent arterial punctures for ABGs
• Correlating capnograph to patient status
– Ascending phase and plateau are altered by uneven emptying of gases
![Page 67: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/67.jpg)
Capnography in Hypoventilation States
• Altered mental status– Sedation
– Alcohol intoxication
– Drug Ingestion
– Stroke
– CNS infections
– Head injury
• Abnormal breathing
• CO2 retention – EtCO2 >50mmHg
![Page 68: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/68.jpg)
Capnography Applicationson Non-intubated Patients
• New applications now being reported
– Pulmonary emboli
– CHF
– DKAr r O xy g e n
O 2
V e inA te y
![Page 69: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/69.jpg)
PULMONARY EMBOLUS
![Page 70: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/70.jpg)
TRANSCUTANEOUS AND CARBON DIOXIDE MONITORS
![Page 71: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/71.jpg)
• Transcutaneous measurements of PO2 (Ptco2) and Pco2 (Ptcco2) are monitoring methods that aim to provide noninvasive estimates of arterial O2 and CO2, or at least trends associated with these variables.
• Transcutaneous monitoring can be applied when expired gas sampling is limited.
• The measurements are based on the diffusion of O2 and CO2 through the skin.
• Used successfully in neonates and infants
![Page 72: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/72.jpg)
• Applied when expired gas sampling is limited
• Measurements are based on the diffusion of CO2and O2 through the skin.
• Warming is used to facilitate gas diffusion.
• Such an increase in temperature promotes increased O2 and CO2 partial pressure at skin surface.
• Ptco2 is usually lower than PaO2, and Ptcco2 is higher than Paco2.
![Page 73: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/73.jpg)
• A transducer using a pH electrode to measure the Pco2 (Stow-Severinghaus electrode) is used.
• A change in pH is proportional to the logarithm of the Pco2 change. For CO2
monitors
• A temperature correction factor is used to estimate Paco2 from Ptcco2.
![Page 74: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/74.jpg)
![Page 75: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/75.jpg)
Uses of Ptcco2
1. Assess the efficacy of mechanical ventilation in respiratory failure.
2. Laparoscopic surgery with prolonged pneumoperitoneum.
3. Deep sedation for ambulatory hysteroscopy in healthy patient.
4. Weaning from mechanical ventilation after off pump CABG.
![Page 76: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/76.jpg)
Uses of Ptco2
• Detect hyperoxia in neonates
• Adults:
1. Wound management
2. peripheral vascular disease
3. hyperbaric medicine.
![Page 77: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/77.jpg)
Limitations
• Poor cutaneous blood flow
• Frequent calibration
• Slow response time
• Skin burns with prolonged application
![Page 78: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/78.jpg)
References
• Understanding anesthesia equipment, 5th
edition Dorsch and Dorsch
• Miller’s Anesthesia 8th edition
• Care fusion capnography handbook
• www.capnography.org
![Page 79: End tidal co2 and transcutaneous monitoring](https://reader034.vdocuments.us/reader034/viewer/2022042607/55a687171a28ab391e8b45a9/html5/thumbnails/79.jpg)
THANK YOU
THE END