Download - Enclosure Power Management Solutions
EnclosurePower ManagementSolutions
• BasicPDU’s• Metered(MD)PDU’s• IntelligentPDU’swith:
• StripLevelMonitoring(W)
• StripLevelMonitoring&SocketSwitching(WS)
• SocketLevelMonitoring&SocketSwitching(WSi)
• SingleandThreePhase
MONITOR
CONTROLMANAGE
AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303
Features
WSi WS W MD BasicSwitched Switched Monitored Metered Basic
Outlet kWh PDU kWh PDU Outlet Measurement Outlet Switch ON / OFF Latching Relay kWh Measurement Hot-pluggable Meter 2.8" Touchscreen DC Module SNMP Hardware Sensor Port x 2 (Temp & Humidity) Management Software 16 x PDU in Single Daisy Chain One IP Access 16 x PDU Levels Aggregate Amp Measurement Local Ammeter
Individual Fuse Option Vertical & Horizontal Mounting Multiple Outlet Configuration Tool-less Mounting Voltage: 110V / 208V / 250V Three Phase - Option Fuse / Circuit Breaker - Option Surge Protector - Option EMI Filter - Option
AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303
Need help choosing a PDU model? Find out more
InfraPower | PDU Range
Intelligent (W Series) PDUs: RackmountPDU’swithdigitallocaltouchscreendisplayandIPnetworkconnectivity.
WModel:StripLevelMonitoring.Reportingtheentire strip data, Amperes, kWh, Volts, PowerFactorandkWcentrally.
WSModel: Strip LevelMonitoring andSocketSwitching.TheaboveMonitored(W)functionalityinaddition to IPnetworkconnectivity toenableuserstoswitchorcontrolindividualoutletsorITequipmentwithinthecabinet.
WSiModel: SocketLevelMonitoringandSocketSwitching. IP network connectivity that allowsusers to switch individual outlets and meterindividualoutletorequipmentconsumption.
Basic PDU: Cost efficient and reliable rackmountpower distribution units which simplydeliver /distributepower fromoutsidethecabinettotheITequipment.
Metered (MD Series) PDU:MD Series PDUs allow true RMScurrent local monitoring via a digitalRMS ammeter.The blue LED displayis easy-to-read from a distance andallows rapid access to the aggregateloadonthecircuit.
FullrangeofAutomatic Transfer Switches (ATS)alsoavailable.
AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303
InfraPowerW SeriesIntelligentPDU’s|Features
Coloured ChassisA simple way to enhance cablemanagement and visualisation of thepower sources. Allows differentiationof primary and redundant power feeds(A&B) if required.Themost commoncombinationsareRed&BlueorBlack&GreyWhite.Othercoloursareavailable.
Field Replaceable DC Module
IP Dongle (SNMP)Hot pluggable IP dongle provides IP remoteaccess to the PDUs using a single IP addresschain.OnlyoneIPdongle isrequiredtoaccessamaximumof16PDUsinadaisychain.Simplyintegrate the IP dongle to the 1st PDU, thenthe entire daisy chain group can be remotelyaccessedoverIP.
FREE
ManagementSoftware
Hot Swappable MeterField replaceable RMS current meter with 2.8”colourLCDdisplaywithtouchscreenfunctionality.Thesharpandhighlyvisibledisplayprovideslocaldataof:• current(AMP)• voltage(Volt)• power(KW)• energyconsumption(KWh),• powerfactoroftheentirePDUThisdatahasameteringaccuracytowithin+/-1%.
Latching Relays*Toprotectmissioncriticalequipmentfrom unplanned downtime, socketswitching must be controlled viabistable/latchingrelays.Ensuringan‘alwayson’operationalperformanceandsocketstatusreturningtoaprepower outage after a planned orunplannedshutdown.
PDU Power Feed EntryBottom feed entry asstandard. Optional Topfeedentry.
*WS&WSiModelPDU’sonly
Available in Single Phase & Three Phase
ProtectionThermal Resettable Fuse• Protectedloadsegmentsfor
increasedreliability• Overloadresetbutton• Costeffectivesolutionfor
safetyoperation
Circuit Breakers (Option) • Protectedloadsegmentsfor
increasedreliability• Overloadswitch• Designedwithfullyshrouded
protectivecovertopreventaccidentalON/OFFoperation
Accidental Release SleevesIECSleevesofferaddedprotectionagainsttheunintentionalremovalof cables from the PDU C13 orC19outlets–see‘Accessories’
Environmental Sensor Ports2xenvironmentalplug inportsfor temperature and humiditymonitoring; all data is thendisplayedlocallyonthePDU.
Multiple Outlet ConfigurationsMultipleoutletconfigurationspereachindividualPDUe.g.OneVerticalPDUwith2xUK,20xC13,4xC19outlets
AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303
InfraPower | PDU Part Code Builder
VerticalButtonMountingKit
VerticalBracketMountingKit
MountingQuick and tool-less integration simplifies PDUinstallation.
Universalmountingkitssupportsallcabinetmodels
• Vertical Button Mounting Kit: Designed forglobal branded cabinets with keyhole typemountingholesontherearverticals
• Vertical Bracket Mounting Kit:EasyinstallationbymountingthePDUtothecabinetcabletray
BothaVerticalButtonMountingKit&VerticalBracketMountingKitaresuppliedasstandardperPDU.
Power Feed Entry AsstandardInfraPowerPDUs have bottompowerfeedentry.
Customisation to topfeed entry is availableonrequest.
Three Phase PDUsW Series Intelligent PowerDistributionUnitsareavailableinThreePhase
• Phasevoltagebalance
• PDUcascadingreducingdataportsandnetworkIPaddresses
• Zeropowerconsumptionlatchingrelayforoutletcontrol
• Switched/MonitoredPDUmodels
• Outlet/circuitlevelmeasurement
• Customconfigurationsavailable
Example PDU Configuration
AH V 02 3 20 1 04 2 2 7AH * ** * ** * ** * * *
AUSTIN HUGHES Direction
Socket Type 1 Socket Type 2 Socket Type 3Rating Model TypeQty Socket Type Qty Socket Type Qty Socket Type
AH V = Vertical 02 3 = UK 45° Sockets 02 1 = C13 Sockets 02 2 = C19 Sockets 1 = 13A 0 = BasicH = Horizontal 04 4 = UK 135° Sockets 04 If no C13 sockets
required insert ‘000’04 If no C19 sockets
required insert ‘000’
2 = 16A 1 = MD06 5 = UK 90° Sockets 06 06 3 = 32A 4 = W08 6 = CEE7/4 Schuko 08 08 4 = 10A 5 = WI 10 7 = Nema Sockets 10 10 5 = 20A 6 = WS12 8 = CEE7/5 Schucko 12 12 6 = 30A 7 = WSi16 If none of these socket
types required insert ‘000’
14 7 = 16A (3P)20 16 8 = 32A (3P) 24 18 9 = 63A
20 (3P = 3 Phase)24
283236
InfraPower|Options
Request a Quotation
3 1 1 1* * * *
Cord Length Input Plug Feed Input ColourOptional Extra
Protection Extra Requirement1 = 1 Meter 1 = 60309 Commando 1 = Bottom 1 = Black RAL 9005 1 = Circuit Breakers L = LSZH Input Cord2 = 2 Meter 2 = C20 IEC320 2 = Top 2 = Blue Pantone 200c 2 = Individually Fused E = External Earth Cord 3 = 3 Meter 3 = UK BS1363 3 = Red Pantone 300c 3 = EMI Filter S = Special Requirement4 = 4 Meter 4 = Schucko 4 = Grey White RAL 9002 4 = Resettable Individual Fuses K = Locking Sockets5 = 5 Meter 5 = Unterminated 5 = Yellow RAL 1018 5 = Surge Protection T = Transfer Switch6 = 6 Meter 6 = C14 IEC320 7 = Purple RAL 40067 = 7 Meter 7 = L6 20P Nema 8 = Orange RAL 10078 = 8 Meter 8 = L6-30P Nema 9 = Green RAL 60299 = 9 Meter0 = 10 Meter
Coloured Power Distribution Units ColouredPDUcasingsallowdifferentiationbetween primary and redundant powersources(generallyA&Bfeeds)withintheServerCabinet.Suggestedcombinations:
• LightGrey+StandardBlack
• Blue+Red
• Orange+Purple
• Yellow+Green
• Othercoloursareavailable
AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303
Socket ConfigurationsMultiple socket configurations are availableperPDU.
All sockets feature local port numberingusingnon-removablesilkscreenlabellingforidentificationandcircuitidentification.
ChoosecolourusingPDUPartCodeBuilderabove(BlackRAL9005asstandarddefault)
ProtectionResettable Fuse:Protectedloadsegmentsforincreasedreliability.Overloadresetbutton
Circuit Breakers:Protectloadsegmentsforincreasedliability,overloadswitch,designedwithfullyshroudedprotectivecovertopreventaccidentalon/off.
EMI Filter:Suppressesconductedinterferenceonasignal/powerline.Linefrequency:50/60HzAttenuation:Upto50dB
Surge Protection:Enhancesthedeviceprotection.Groundsunwantedvoltagesabovesafethreshold.
ChooseProtectiontypeusingPDUPartCodeBuilderabove(ThermalResettableFuseasstandarddefault)
Check out the InfraPower PDU Video
Example PDU ConfigurationAH V 02 3 20 1 04 2 2 7AH * ** * ** * ** * * *
AUSTIN HUGHES Direction
Socket Type 1 Socket Type 2 Socket Type 3Rating Model TypeQty Socket Type Qty Socket Type Qty Socket Type
AH V = Vertical 02 3 = UK 45° Sockets 02 1 = C13 Sockets 02 2 = C19 Sockets 1 = 13A 0 = BasicH = Horizontal 04 4 = UK 135° Sockets 04 If no C13 sockets
required insert ‘000’04 If no C19 sockets
required insert ‘000’
2 = 16A 1 = MD06 5 = UK 90° Sockets 06 06 3 = 32A 4 = W08 6 = CEE7/4 Schuko 08 08 4 = 10A 5 = WI 10 7 = Nema Sockets 10 10 5 = 20A 6 = WS12 8 = CEE7/5 Schucko 12 12 6 = 30A 7 = WSi16 If none of these socket
types required insert ‘000’
14 7 = 16A (3P)20 16 8 = 32A (3P) 24 18 9 = 63A
20 (3P = 3 Phase)24
283236
AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303
InfraPowerW SeriesIntelligentPDU’s|Connectivity
InfraPowerW SeriesIntelligentPDU’s|Software
IP Dongle & Daisy Chain Patented IP Dongle provides IP remote access tothePDUsbyatruenetworkIPaddresschain.Only1xIPdongleallowsaccesstomax.16PDUsinasingledaisychain.
Save the IP Address Cost of Your Data CenterInfraPowerManagerSoftware(IPM-04) issuppliedFree or utilise 3rd Party DCIM (via SNMP). Cost-efficient PDU management can be achieved byapplyingIPdongle&daisychain.
1 x IP Up to 16 PDU’s
Max. cabling distance between 2 x cascaded PDU’s up to 20 meters
InfraPowerManagerenhancesthebenefitsofWSeriesPDUsbydeliveringacentralisedremotemanagementplatform for thePDUs inmultipleIP-accessgroups.
The administrator can remotely manage thePDUsandtheenvironmentalsensorsconnectedbythewebbrowser.
• Widefunctionality
• ConciseMonitoringPages
• MassscalePDUmanagement
• Scalablesolution
• FlexibilitybyMultipleUsers
• Costeffective
InfraPower Manager Software (Free) UltrahighdensityPDUManagementcanbeachievedwithInfraPowerManager,theassociatedsoftwareforWSeriesPDUs.SupportingremotemanagementofmultiplePDUdaisychaingroups.
IPM-04: Supports up to 800 PDU’s (50 PDU Groups)
IPM-04providesthebasicfunctionsof:• Monitoringormeasurement ofAmps,Volts, kW,
kWh,PowerfactorandTemperature/Humidity
• RemoteswitchingON/OFFperindividualpoweroutlets
• Reporting
• Alarmsetting
• PDUOutletmeasurement
• Grouping and chart reporting (These functionsareprovidedbyhighersoftwareeditions)
ToarrangeaSoftwareDemonstrationplease Contact Us
External Door Mount PDU DisplayThe external door mount PDUdisplayprovidesahighlyvisiblelocaldisplaywithouttheneedtoopen the cabinet’s rear door toreadthePDU(s)information.
• External Door Mount PDUDisplayprovidesRJ-11portx2forPDUamp.&Temperaturemonitoring
• ThedisplaywillbeconnectedbacktoeachIPPDUviadooranda3mRJ-11cable
• Once connected, the reading of PDU ampsand temperature shows in the external doormountdisplay
IP Dongle• Patenteddesign
• Hotpluggableforeasyintegration
• AllowsIPremoteaccesstothePDUsbyasingleIPaddress
• OneIPdonglesupportsmax.16
• PDUsindaisychain
• Highlycosteffectivemethodto
accesstheintelligentPDUs
• SNMP
AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303AustinHughesEuropeLtd|www.austin-hughes.eu|[email protected] |+44(0)2380529303
InfraPower|Accessories
Sensors• Externalsensoravailablewith
2Mor4Mcord
• Plugandplay
• Lowprofiledesignwithmagneticbaseforeasyaffixingtotherackcabinet
• PairofsensorscanbeconnectedtoonesingleWseriesPDUmeter
Accidental Release SleevesAvoids accidental removal of powerleadstoactiveequipmentbyengineersworkingwithinrackPDU’sC13andC19sockets.ByusingIECsleeves,apowercablerequires12Kgofforcetoremove.
Coloured Power CordsProvide the simplest way toenhance cablemanagementandvisualisepowersources.
IP DonglesAHAPDUIPD02S IP Dongle for Vertical PDU
AHAPDUIPDH02S IP Dongle for Horizontal PDU
Temperature & Humidity SensorsAH-IG-T012M Temperature Sensor, 2 MeterAH-IG-T014M Temperature Sensor, 4 Meter
AH-IG-TH012M Temperature & Humidity Sensor, 2 MeterAH-IG-TH014M Temperature & Humidity Sensor, 4 Meter
Accidental Release SleevesIEC_C13 C13 Cord Sleeves
IEC_C19 C19 Cord Sleeves
External Door Mount PDU DisplayAH-WS-DIS01 External PDU Display
C13-C14 CordsAHA111001 C13-C14 Black 1MAHA112001 C13-C14 Black 2MAHA113001 C13-C14 Black 3MAHA111002 C13-C14 Blue 1MAHA112002 C13-C14 Blue 2MAHA113002 C13-C14 Blue 3MAHA111005 C13-C14 Orange 1MAHA112005 C13-C14 Orange 2MAHA113005 C13-C14 Orange 3M
C19-C20 CordsAHA221001 C19-C20 Black 1MAHA222001 C19-C20 Black 2MAHA223001 C19-C20 Black 3MAHA221002 C19-C20 Blue 1MAHA222002 C19-C20 Blue 2MAHA223002 C19-C20 Blue 3MAHA221005 C19-C20 Orange 1MAHA222005 C19-C20 Orange 2MAHA223005 C19-C20 Orange 3M
Integrated Solutions
InfraPowerIntelligentWSeriesPDUscanbeincorporatedintoInfraSolutionXtoenablePDUmonitoringandcontrolinadditiontoSmartCardAccessandEnvironmentalManagement.
InfraSolutionXhasSNMPforoptionalintegrationtotheexistingDCIMofDataCentres.
Find out more
Automatic Transfer Switches
TocomplimentInfraPowerPDU’sacomprehensiverangeofAutomaticTransferSwitches(ATS)areavailable.
InfraPowerATSprovidesredundantpowerforsinglecordedequipmentwithautoswitchingrelayforseamlesspowertransfer.
Find out more
In-Line Meters
SingleandThreePhaseIn-LineMetersdesignedtoallowBasicPowerDistributionUnitstobeupgradedwithlocalmonitoringandremotemanagement.
Find out more
Thecompanyreservestherighttomodifyproductspecificationswithoutpriornoticeandassumesnoresponsibilityforanyerrorwhichmayappearinthispublication.
Allbrandnames,logosandregisteredtrademarksarepropertiesoftheirrespectiveowners.
Austin Hughes Europe [email protected]+44(0)2380529303