Bulletin 700
8
Relays and Timers
Electronic High Performance Timing Relays• Bulletin 700-FS
Economy Timing Relays• Bulletin 700-FE
Pages 8-5…8-14
Pages 8-15…8-22
Digital Timing Relays• Bulletin 700-HX
Dial Timing Relays• Bulletin 700-HR
Pages 8-23…8-28
Pages 8-29…8-34
Plug-in Style Relays• Bulletin 700-HA
• Bulletin 700-HC
• Bulletin 700-HF
• Bulletin 700-HK
Pages 8-35…8-44
Pages 8-45…8-51
Pages 8-45…8-51
Pages 8-45…8-51
Control Relays• Bulletin 700-M• Bulletin 700-CF
• Bulletin 700S-CFSafety Control Relays
Page 8-53…8-68
Page 8-53…8-68
Rockwell Automation 8-1
Bulletin 700
8
Relays and TimersOverview
Functions 700-FS 700-FE 700-HX 700-HRSwitching current AC-1 250 VAC 8 A 5 A 5 A 5 A
Contact Functions
N.O. on basic device min./max. — 1 — —
Changeover contacts on basic device min./max. 1 … 2 1 1 2
Instantaneous contacts on basic device min./max. 1 — — 1
Timing Functions
Multi function min./max. 0.05 s … 60 h 0.05 s … 10 h 0.05 s … 9999 h 0.05 s … 60 h
Star delta min./max. 0.05 s … 10 min 0.15 s … 10 min — —
On-delay min./max. 0.05 s … 60 h 0.05 s … 10 h 0.05 s … 9999 h 0.05 s … 60 h
On-delay with impulse control min./max. 0.05 s … 60 h — 0.05 s … 9999 h 0.05 s … 60 h
On-delay with time memory function min./max. — — 0.05 s … 9999 h —
Integrator — on-delay with accumulation min./max. — — 0.05 s … 9999 h —
Reset delay min./max. 0.05 s … 60 h 0.05 s … 10 h 0.05 s … 9999 h 0.05 s … 60 h
Reset delay without supply voltage min./max. 0.15 s … 10 min — — —
Pick-up and reset delay min./max. 0.05 s … 60 h — — —
One-shot min./max. 0.05 s … 60 h 0.05 s … 10 h 0.05 s … 9999 h 0.05 s … 60 h
One-shot / Watch-dog min./max. 0.05 s … 60 h — — —
Fleeting off-delay min./max. 0.05 s … 60 h 0.05 s … 10 h — —
Flashing started by impulse min./max. 0.05 s … 60 h 0.05 s … 10 h — —
Flashing started by pause min./max. 0.05 s … 60 h — 0.05 s … 9999 h 0.05 s … 60 h
Unequal repeat cycle min./max. 0.05 s … 60 h — 0.05 s … 9999 h —
Pulse generator min./max. 0.05 s … 60 h — — —
Pulse converter min./max. 0.05 s … 60 h 0.05 s … 10 h — —
Product Information Pages 8-5 … 8-14 8-15 … 8-21 8-23 … 8-28 8-29 … 8-34
Electronic high performance timing relay 700-FS
Economy timing relays700-FE
Digital timing relay700-HX
Dial timing relay700-HR
8-2 Rockwell Automation
Bulletin 700
8
Relays and TimersOverview
Functions 700-HA 700-HC 700-HF 700-HKSwitching current AC-1 250 VAC 10 A 1 … 5 A 10 A 5 … 10 A
Contact Function
Changeover contacts on basic device min./max. 2 … 3 4 2 … 4 1 … 2
Timing Functions
Pick-up delay min./max. 0.1 s … 240 h — — —
Pick-up delay with impulse control min./max. 0.1 s … 240 h — — —
Reset delay min./max. 0.1 s … 240 h — — —
One-shot min./max. 0.1 s … 240 h — — —
Fleeting on-delay min./max. 0.1 s … 240 h — — —
Flashing started by impulse min./max. 0.1 s … 240 h — — —
Flashing started by pause min./max. 0.1 s … 240 h — — —
Impulse shaper min./max. 0.1 s … 240 h — — —
Product Information Pages 8-35 … 8-43 8-45 … 8-51 8-45 … 8-51 8-45 … 8-51
Plug-in relay with relay socket Cat. No. 700-HA
Multifunction timerCat. No. 700-HT1
SocketCat. No. 700-HN203
Plug-in relayCat. No. 700-HA…
Plug-in relayCat. No. 700-HC
Plug-in relayCat. No. 700-HK
Plug-in relayCat. No. 700-HF
Rockwell Automation 8-3
Bulletin 700
8
Relays and TimersOverview
Functions 700-M 700-MB 700-CF 700S-CFSwitching current AC-1 40 °C 240 VAC 16 A 12 A 25 A 25 A
Contact Functions
N.O. on basic device max. 4 4 4 3
N.O. on auxiliary contact block max. 8 8 8 3
N.C. on basic device max. 2 2 2 1
N.C. on auxiliary contact block max. 4 4 4 3
Product Information Pages 8-53 … 8-68
Miniature control relay Cat. No. 700-M
Control relayCat. No. 700-CF
Safety control relayCat. No. 700S-CF
Miniature control relay Cat. No. 700-MB
8-4 Rockwell Automation
Bulletin 700-FS
8
Electronic High Performance Timing Relays
Table of ContentsDescription Page Description PageOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Type Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
Product Selection
Multi-Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
Single-Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8
Unequal Repeat Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10
Reset Delay without Supply Voltage. . . . . . . . . . . . . . . . . . . . 8-10
Star-delta Timing Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11
Specifications
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12
Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
Approvals and Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-14
Bulletin 700-FS Timing Relays• Multi-Function
10 functions selectable10 time settings selectable
• Single-Functions11 single-functions selectable12 time settings available
• Special Functions3 single-functions selectable12 time settings available
Bulletin 700-FS Timing Relays• Multi-Function
10 functions selectable10 time settings available
• Single-Functions2 single-functions selectable10 time settings available
Rockwell Automation 8-5
Bulletin 700-FS
8
Electronic High Performance Timing RelaysType Designation
Multi-Function
Single-Functions
Special-Functions
700-FS M 3 U U23
Function Assem. of Contacts Time Range Supply VoltageM Multi-function timing relays
8 single-functionsON and OFF function additional(for commissioning and inspection)
3 1 Changeover contact 1 C/O
4 2 Changeover contacts 2 C/O(output 2 programmable as instantaneous contact)
U 0.05 s … 60 h Z12 12 VDCU23 24 … 48 VDC
24 … 240 V 50/60 HzU18 24 … 240 VUCA40 400 V 50/60 Hz
700-FS A 3 U U23
Functions Assem. of Contacts Time Range Supply VoltageA On-delayB Off-delay
3 1 Changeover contact 1 C/O
4 2 Changeover contacts 2 C/O
U 0.05 s … 60 h Z12 12 VDCU23 24 … 48 VDC
24 … 240 V 50/60 HzA40 400 V 50/60 Hz
700-FS A 3 A U23
Functions Assem. of Contacts Time Range Supply VoltageA On-delayB Reset delayC Pick-up and reset delayD One-shotE Fleeting off-delayF Flashing started by impulseG Flashing started by pauseI Pulse generatorJ On-delay with impulse controlK One-shot / Watch dogL Pulse converter
3 1 Changeover contact 1 C/O
A 0.05 … 1 sB 0.15 … 3 sC 0.5 … 10 sD 1.5 … 30 sE 0.05 … 1 minF 0.15 … 3 minG 0.5 … 10 minH 1.5 … 30 minI 0.05 … 1 hJ 0.15 … 3 hK 0.5 … 10 hL 3 … 60 h
Z12 12 VDCU23 24 … 48 VDC
24 … 240 V 50/60 HzU18 24 … 240 VUCA40 400 V 50/60 Hz
700-FS H 3 U U23
Functions Assem. of Contacts Time Range Supply VoltageH Unequal repeat cycle 3 1 Changeover
contact 1 C/OU 0.05 s … 60 hV 2 x 0.05 s… 60 h
Z12 12 VDCU23 24 … 48 VDC
24 … 240 V 50/60 HzA40 400 V 50/60 Hz
700-FS Q 3 Q U18
Functions Assem. of Contacts Time Range Supply VoltageQ Off-delay without
Supply Voltages3 1 Changeover
contact 1 C/O4 2 Changeover
contacts 2 C/O
Q 0.15 s … 10 min U18 24 … 240 VUC
700-FS Y 2 C U23
Functions Assem. of Contacts Time Ranges Supply VoltagesY Star-Delta Timing Relays 2 2 normally open
contacts 2 N.O.C 0.5 … 10 sD 1.5 … 30 sE 0.05 … 1 minF 0.15 … 3 minG 0.5 … 10 min
U23 24 … 48 VDC24 … 240 V 50/60 Hz
A40 400 V 50/60 Hz
8-6 Rockwell Automation
Bulletin 700-FS
8
Electronic High Performance Timing RelaysProduct Selection
Multi-FunctionOverall-width 22.5 mm according to DIN 43880
➊ A voltage other than the supply voltage can be used for the impulse control.➋ Output 2, selectable as instantaneous contact with sliding switch on front panel➌ Bridge or potentiometer 10 kΩ, min. 0.25 W (low voltage) for external setting.
Description
Multi-function timing relays 700-FSM includes 10 setting functions:(A) - On-delay(B) - Off-delay(C) - On- and off-delay(D) - One-shot(E) - Fleeting off-delay(F) - Flashing started by impulse(I) - Pulse generator(L) - Pulse converter(On) - ON-Function *(Off) - OFF-Function *
* (for commissioning and inspection)
Multi-Time Setting Range 0.05 s…60 h(1s) 0.05…1 s(3s) 0.15…3 s(10s) 0.5…10 s(1mn) 0.05…1 min(3mn) 0.15…3 min(10mn) 0.5…10 min(1h) 0.05…1 h(3h) 0.15…3 h(10h) 0.5…10 h(60h) 3…60 h
Availability Supply Voltages (A1/A2) Cat. No. PQ Cat. No. PQfrom stock U23 24…48 VDC; 24…240 V, 50/60 Hz 700-FSM3UU23
1
700-FSM4UU23
1on request Z12 12 VDC 700-FSM3UZ12 700-FSM4UZ12on request U18 24…240 VUC 700-FSM3UU18 700-FSM4UU18on request A40 400 V, 50/60 Hz 700-FSM3UA40 700-FSM4UA40
21 2422
25 2826
➋
15
18 16
25
28 26
➌ ➋
Z1 Z224 22
21
A1/A2
S
15 1816
U
Output 1
LED
A1/B1
tt
Output 2
Output 2
tt
A1
A2
L/+
N/-
B1 S
➊
A1/A2U
15 1816
Output 1
LED
Output 2 21 2422
25 2826
Output 2
➋
S
t
15A1
A2
L/+
N/-18 16
25
28 26
➌ ➋
Z1 Z224 22
21B1 S
➊
t
A1/B1
t
A1/A2U
15 1816
t
0.5s
0.5s 15A1
A2
L/+
N/-18 16
Output 1
LED
Output 221 24
22
25 2826Output 2
➋
25
28 26
➌ ➋
Z1 Z224 22
21
21 2422
252826
➋
U
15 1816Output 1
LED
A1/B1
t
Output 2 t
Output 2
15A1
A2
L/+
N/-18 16
25
28 26
➌ ➋
Z1 Z224 22
21
15 1816
U
Output 1
LED
A1/A2
tt tt t
Output 2 tt tt t
21 2422
25 2826
➋Output 2
15A1
A2
L/+
N/-18 16
25
28 26
➌ ➋
Z1 Z224 22
21
21 2422
252826
➋
15A1
A2
L/+
N/-18 16
25
28 26
➌ ➋
Z1 Z224 22
21B1 S
➊U
15 1816Output 1
LED
A1/A2
S A1/B1
t
Output 2 t
Output 2
Output 1
Output 2
LED
A1/A2
15 1816
25 2826
U
Output 1
Output 2
LED
U
15 1816
A1/A2
25 2826
(A) On-delay (B) Off-delay
(C) On- and Off-delay (D) One-shot
(E) Fleeting off-delay (F) Flashing started by impulse
(L) Pulse converter
(Off) OFF-Function
(I) Pulse generator
(On) ON-Function Unmistakably Function Display by LEDOutput in rest position, no timing
Output in rest position, time running
Output in operating position, no timing
Output in operating position, time running
15A1
A2
L/+
N/-18 16
A1/A2U
15 1816t
Output 1
LEDOutput 2
21 2422
25 2826t
Output 2➋
25
28 26
➌ ➋
Z1 Z224 22
21 A1/A2U
15 1816
Output 1
LED
Output 2 21 2422
25 2826
Output 2
➋
S
t
15A1
A2
L/+
N/-18 16
25
28 26
➌ ➋
Z1 Z224 22
21B1 S
➊
t
A1/B1
PQ = Package Quantity
Rockwell Automation 8-7
Accessories - Page 8-11Specifications - Page 8-12Dimensions - Page 8-14
Bulletin 700-FS
8
Electronic High Performance Timing RelaysProduct Selection
Single-FunctionOverall-width 22.5 mm according to DIN 43880
➊ A voltage other than the supply voltage can be used for the impulse control➋ Output 2, selectable as instantaneous contact with sliding switch on front panel➌ Bridge or potentiometer 10 kΩ, min. 0.25 W (low voltage) for external setting
Description
Supply Voltages (A1/A2)Z12 12 VDCU23 24 … 48 VDC
24 … 240 V, 50/60 HzU18 24 … 240 VUCA40 400 V, 50/60 Hz
Available Mono-Time RangesComplete the Cat. No. with the corresponding identification from the table on the next page (bottom).
Additionally for Functions A and B:U Available Mono-Time Ranges 0.05 s…60 h(1s) 0.05…1 s (1mn) 0.05…1 min (1h) 0.05…1 h(3s) 0.15…3 s (3mn) 0.15…3 min (3h) 0.15…3 h(10s) 0.5…10 s (10mn) 0.5…10 min (10h) 0.5…10 h
(60h) 3…60 h
Function Diagrams / Connection Diagrams Cat. No. PQ Cat. No. PQ
(A) On-delayThe output contact changes state after the time delay is completed.
from stock:700-FSA3U23700-FSA3UU23
on request:700-FSA3Z12700-FSA3UZ12700-FSA3U18700-FSA3A40700-FSA3UA40
1
from stock:700-FSA4UU23
on request:700-FSA4UZ12700-FSA4UA40
1
(B) Off-delayThe output contact changes state when switch „S“ is closed. When switch „S“ is opened, the time delay begins. After the time delay is completed, the con-tact returns to shelf state.
from stock:700-FSB3U23700-FSB3UU23
on request:700-FSB3Z12700-FSB3UZ12700-FSB3U18700-FSB3A40700-FSB3UA40
1
from stock:700-FSB4UU23
on request:700-FSB4UZ12700-FSB4UA40
1
(C) On- and Off-delayThe output contact changes state after the time delay is completed. After the time delay is completed, the contact returns to shelf state.
from stock:700-FSC3U23
on request:700-FSC3Z12700-FSC3U18700-FSC3A40
1 —
1
(D) One-shotThe output contact changes state when the relay is energised. The output contact returns to shelf state when the time delay is completed.
from stock:700-FSD3U23
on request:700-FSD3Z12700-FSD3U18700-FSD3A40
1 —
A1/A2U
15 1816t
15A1
A2
L/+
N/- 18 16
Output
LED
15A1
A2
L/+
N/-18 16
A1/A2U
15 1816t
Output 1
LEDOutput 2
21 2422
25 2826t
Output 2➋
25
28 26
➌ ➋
Z1 Z224 22
21
A1/A2
S
15 1816
15A1
A2
L/+
N/- 18 16
B1 S
➊
t
U
Output
LED
A1/B1
A1/A2U
15 1816
Output 1
LED
Output 2 21 2422
25 2826
Output 2
➋
S
t
15A1
A2
L/+
N/-18 16
25
28 26
➌ ➋
Z1 Z224 22
21B1 S
➊
t
A1/B1
A1/A2
S
15 1816
U
Output
LED
A1/B1
tt
15A1
A2
L/+
N/-18 16
B1 S
➊
15A1
A2
L/+
N/-18 16
U
15 1816
Output
LED
A1/B1
t
PQ = Package Quantity
8-8 Rockwell Automation
Accessories - Page 8-11Specifications - Page 8-12Dimensions - Page 8-14
Bulletin 700-FS
8
Electronic High Performance Timing RelaysProduct Selection
➊ A voltage other than the supply voltage can be used for the impulse control
Mono-Time RangesComplete the Cat. No. with mono-time range identification
Description
Function Diagrams/ Connection Diagrams Cat. No. PQ(E) Fleeting off-delayThe output contact changes state after closing and opening switch „S“. After the time delay is completed, the contact returns to shelf state. from stock:
700-FSE3U23on request:
700-FSE3Z12700-FSE3U18700-FSE3A40
1
(F) Flashing Started by ImpulseThe output contact changes state when power is applied. At the end of the time delay, the output contact returns to shelf state. This cycle continues until the power is removed.
from stock:700-FSF3U23
on request:700-FSF3Z12700-FSF3U18700-FSF3A40
1
(G) Flashing Started by PauseThe output contact remains in the shelf state until the time delay is completed. When the time delay is completed, the contact changes state. This cycle continues until the power is removed.
from stock:700-FSG3U23
on request:700-FSG3Z12700-FSG3U18700-FSG3A40
1
(I) On-delay Pulse Generator The output contact changes state when the time delay is completed. After 0.5 s the contact opens. from stock:
700-FSI3U23on request:
700-FSI3Z12700-FSI3U18700-FSI3A40
1
(J) On-delay (Pulse Controlled)When switch „S“ is closed, the output contact changes state. from stock:
700-FSJ3U23on request:
700-FSJ3Z12700-FSJ3U18700-FSJ3A40
1
(K) One-Shot / Watch Dog When switch „S is closed, the output contact changes state. from stock:
700-FSK3U23on request:
700-FSK3Z12700-FSK3U18700-FSK3A40
1
(L) Pulse converterWhen switch „S is closed, the output contact changes state. The time „t“ is not influenced by the duration of the control pulse. from stock:
700-FSL3U23on request:
700-FSL3Z12700-FSL3U18700-FSL3A40
1
Time Ranges 0.05…1 s 0.15…3 s 0.5…10 s 1.5…30 s 0.05…1 min 0.15…3 min A B C D E F
Time Ranges 0.5…10 min 1.5…30 min 0.05…1 h 0.15…3 h 0.5…10 h 3.0…60 h G H I J K L
A1/A2
S
15 1816
15A1
A2
L/+
N/- 18 16
B1 S
➊
t
U
Output
LED
A1/B1
15A1
A2
L/+
N/- 18 16
15 1816
U
Output 1
LED
A1/A2
tt tt t
tt tt t
15A1
A2
L/+
N/- 18 16
15 1816
U
Output 1
LED
A1/A2
1816
15A1
A2
L/+
N/- 18 16
A1/A2U
15t
0.5sOutput
LED
15A1
A2
L/+
N/- 18 16
B1 S
➊A1/A2
S
15 1816t
U
Ausgang
LED
A1/B1
15A1
A2
L/+
N/- 18 16
B1 S
➊A1/A2
S
15 1816
t
U
Output
LED
A1/B1
15A1
A2
L/+
N/- 18 16
B1 S
➊A1/A2
S
15 1816
t
U
Output
LED
A1/B1
PQ = Package Quantity
Rockwell Automation 8-9
Accessories - Page 8-11Specifications - Page 8-12Dimensions - Page 8-14
Bulletin 700-FS
8
Electronic High Performance Timing RelaysProduct Selection
Special Functions
Overall-width 22.5 mm according to DIN 43880
Description
Multi-Time Setting Ranges
U 0.05 s…60 hV 2 x 0.05 s…60 h
Supply Voltages (A1/A2)Z12 12 VDCU23 24 … 48 VDC
24 … 240 V, 50/60 HzA40 400 V, 50/60 Hz
(1s) 0.05… 1 s (10mn) 0.5…10 min(3s) 0.15… 3 s (1h) 0.05…1 h(10s) 0.5… 10 s (3h) 0.15…3 h(1mn) 0.05…1 min (10h) 0.5…10 h(3mn) 0.15…3 min (60h) 3… 60 h
Function Diagrams/ Connection Diagrams Cat. No. PQ(H) Flasher (Repeat Cycle Starting with Pulse or Pause)The repeat cycle timer permits different setting for on and off times.The following operating modes are possible depending on device and drive:- Output starts with pulse or pause- Controlled by supply voltages or additional control contact.- Period runoff or continuous cycles (when operated with control contact).- Joint selection of time ranges with 700-FSH3U or individual selection of
time range with 700-FSH3V for pulse and pause time.
from stock:700-FSH3UU23700-FSH3VU23
on request:700-FSH3UZ12700-FSH3VZ12700-FSH3UA40700-FSH3VA40
1
Supply Voltage Controlled, Oscillating Mode Starting with Pause
Supply Voltage Controlled, Oscillating Mode Starting with Pulse
Pulse controlled, Oscillating Mode Starting with Pulse and Pause
Pulse controlled, Oscillating Mode Starting with Pulse
➊ A voltage other than the supply voltage can be used for the impulse control
Supply Voltages (A1/A2)U18 24 … 240 VUC
Multi-Time Setting Ranges Q 0.15 s…10 min
(2.5s) 0.15 … 2.5 s (80s) 4 … 80s(10s) 0.5 … 10 s (10mn) 0.5 … 10min
Function Diagrams/ Connection Diagrams Cat. No. PQ Cat. No. PQ(Q) Off-delay without Supply VoltagesWhen input power is turned on, the output contact changes state. When the power is removed, the time delay begins. The output contact returns to shelf state at the end of the time delay.
from stock:700-FSQ3QU18 1
from stock:700-FSQ4QU18 1
t1t1t2t2
15A1 B1
A2
L/+
N/- 18 16
15 1816
U
Output
LED
A1/A2
SA1/B1
S
t1
15A1
A2
L/+
N/- 18 1615 18
16
U
Output
LED
A1/A2
SA1/B1
t1t2t2
B1S
15A1
A2
L/+
N/- 18 16
B1 S
➊A1/A2
S
15 1816
t1t1t2t2
U
Output
LED
A1/B1
t1
15 1816Output
LED
t1t2t2
15A1
A2
L/+
N/- 18 16
B1 S
➊A1/A2
SU
A1/B1
U A1/A2
15 1816
15A1
A2
L/+
N/- 18 16
tOutput
LED
U A1/A2
25 2826
A1
A2
L/+
N/-
tOutput 2
15 1816
tOutput 1
LED
15
18 16
25
28 26
8-10 Rockwell Automation
Accessories - Page 8-11Specifications - Page 8-12Dimensions - Page 8-14
Bulletin 700-FS
8
Electronic High Performance Timing RelaysProduct Selection/ Accessories
Special Functions
Overall-width 22.5 mm according to DIN 43880
Mono-Time RangesComplete the Cat. No. with mono-time identification.
Accessories
Labelling Material
Description
Supply Voltages (A1/A2)U23 24 … 48 VDC
24 …240 V, 50/60 HzA40 400 V, 50/60 Hz
Available Mono-Time RangesComplete the Cat. No. with the cor-responding identification from the table below.
Function Diagrams / Connection Diagrams Cat. No. PQ
(Y) Star-Delta Timing Relay When power is applied, the output contact (Y) changes state. After the fixed time tu, the output contact ∆ changes state. Both output contacts return to shelf state whenever the power is removed.
from stock:700-FSY2U23
on request:700-FSY2A40
1
Time Ranges 0.5…10 s 1.5…30 s 0.05…1 min 0.15…3 min 0.5…10 min
C D E F G
Description Cat. No. PQ
Setting Knob with ScaleRaised setting knob for time setting without tools
700-FSK 10
Screw AdapterFor surface mounting according to drilling plan EN 50 002
199-FSA 5
• Uniform labelling material for contactors, motor protection devices, timing relays and circuit breakers.For product information and ordering informations see chapter 3.
A1/A2U
17/28
17A1
A2
L
N 18 28
17/18
∆Y
t
tu = 50...65 msLED
PQ = Package Quantity
Rockwell Automation 8-11
Dimensions - Page 8-14
Bulletin 700-FS
8
Electronic High Performance Timing RelaysSpecifications
Specifications
Time characteristics (according to VDE 0435, Part 2021)Setting accuracy ± 5% of the rime range end value (tmax.)
Repeatability ± 0.2% of the setting valueTolerances voltage: ± 0.001%/%∆U
temperature: ± 0.025%/°C
Supply
Supply Voltages 24…48 VDC and 24…240 VAC, 50/60 Hz (dual voltage)Voltage ToleranceAC DC
-15%/+10%-20%/+20%
Power Consumptionat 240 VAC [VA]at 24 VDC [W]
50.5
Time Energised 100%Reset Value [ms] 50Voltage Isolation <20 ms without reset (supply voltage)Cable Length of Supply Voltage Control [m] max. 250
Pulse Control (B1)
Pulse DurationAC [ms]DC [ms]
>50>30
Input Voltage same as supply voltage rangeInput Current [mA] 1Cable Lengthwithout parallel load between B1 and A2 [m]with load (<3 kΩ) between B1 and A2 [m]
max. 250max. 50
Outputs
Contact Type Relays as changeover switchSwitching Capacity Voltage: 440 VAC
Current Ith: 8 APower: 2000 VA
according to IEC 947-5-1: 3 A/440 VAC (inductive load, AC 14)3 A/250 VAC (inductive load, AC 15)1 A/24 VDC (inductive load, DC 13)
according to UL 508: 1.5 A/250 VAC (B300)3 A/120 VAC (B300)
Short-circuit Resistance 10 A gLLifespanmechanical [operations]
electrical [operations]
30 Mio.
4 Mio. at 1 A/250 VAC, cos ϕ = 10.2 Mio. at 6 A/250 VAC, cos ϕ = 1
1.5 Mio. at 1 A/250 VAC, cos ϕ = 0.30.3 Mio. at 3 A/250 VAC, cos ϕ = 0.3
0.5 Mio. at 6 A/24 VDC, resistive2 Mio. at4 A/24 VDC, resistive
2 Mio. at 0.2 A/230 VDC, resistive1 Mio. at 0.4 A/24 VDC, L/R = 20 ms
1 Mio. at 0.2 A/110 VDC, L/R = 20 ms1 Mio. at 0.1 A/230 VDC, L/R = 20 ms
State Indication 1 LED, combination signal
8-12 Rockwell Automation
Product Selection - Page 8-7
Bulletin 700-FS
8
Electronic High Performance Timing RelaysSpecifications
General Data
Insulation Characteristics 2 kVAC/50 Hz test voltage according to VDE 0435and 6 kV 1.2/50 µs surge voltage according to IEC 947-1
between all inputs and outputsEMC Interference ImmunitySurge Capacity of Supply VoltageBurstESD DischargeElectromagnetic HF fieldConducted electromagnetic HF field signal
Performance of following requirements:according to IEC 1000-4-5: 4 kV 1.2/50 µsaccording to IEC 1000-4-4: 6 kV 6/50 ns
according to IEC 1000-4-2: contact 8 kV, air 8 kVaccording to IEC 801-3: level 3according to IEC 801-6: level 3
EMC Emmission electromagnetical field according to EN 55 022: class BSafe Isolation according to VDE 106, part 101Climatic Withstand 56 cycles (24 h) at 25…40°C and 95% rel. humidity
according to IEC 68-2-30 and IEC 68-2-3Vibration Resistance 4 G in 3 axis at 10…500 Hz, test FC according to IEC 68-2-6Shock Resistance 50 G according to IEC 68-2-27Protection ClassEnclosureTerminals
IP 40, IP 30 (single-function) IP 20 according to IEC 947-1
Weight [g] 100Approvals CE, UL Listed, C-UL Listed, Germanischer LloydAmbient TemperatureOpen [°C]Enclosed [°C]Storage [°C]
-25 … +60-25 … +45-40 … +85
Terminals Screw terminal M3.5 for pozidrive No.2, Philips and slotted screws No. 2. Suitable for power screw driver. Rated tightening torque 0.8 Nm (max. 1.2 Nm)
Dual-chamber system for terminal cross-sections of 1 x 0.5 mm2 … 2 x 2.5 mm2
(solid) or 2 x 2.5 mm2 (stranded, flexible with sleeve), AWG 20…14.Finger protection according to VDE 0106
Mounting Front mounting; For snap-on mounting on DIN rail 35 mm or screw fixing by adapter and 2 screws M4
Rockwell Automation 8-13
Product Selection - Page 8-7
Bulletin 700-FS
8
Electronic High Performance Timing RelaysDimensions
Dimensions are shown in millimeters
78.8
22.5
35
96
101
109
7
78.8
22.5
35
96
101
109
7
35 58 75
22.5
4.3
9
13
217 12
4.3
5.5
700-FS (1 C/O) 700-FS (2 C/O)
700-FSH3V… 199-FSA
78.8
22.5
357
96
101
109
78.8
22.5
35
96
101
109
7
8-14 Rockwell Automation
Product Selection - Page 8-7
Bulletin 700-FE
8
Economy Timing Relays
Table of ContentsDescription Page Description PageOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Type Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-16
Product Selection
Multi-function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-17
Single-functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-18
Star-Delta-Timing Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-19
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-19
Specifications
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-20
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-21
Standards and Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-21
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-22
Bulletin 700-FE Timing Relay
• Multi-Function4 functions selectable4 time settings selectable
• Single-Functions4 single-functions selectable4 time settings selectable
Bulletin 700-FE Timing Relay
• Multi-Function4 functions selectable6 time settings selectable
• Single-Functions6 single-functions selectable6 time settings selectable
• Special Function1 single-function4 time settings selectable
Rockwell Automation 8-15
Bulletin 700-FE
8
Economy Timing RelaysType Designation
Multi-Function
Single-Function
Special Function
700-FE M 1 R U22
FunctionAssembly of
ContactsTime Ranges Supply Voltages
M Multi-function timing relays witha single-function A, B, D and F
1 1 normally open contact 1 N.O.
R 0.5 s…1 h U22 24 VUC110…240 V 50/60 Hz
700-FE M 3 T U23
FunctionAssembly of
ContactsTime Ranges Supply Voltages
M Multi-function timing relays witha single-function A, B, D and F
3 1 changeover contact 1 C/O
T 0.05 s…10 h U23 24…48 VDC24…240 V 50/60 Hz
700-FE A 1 S U22
FunctionAssembly of
ContactsTime Ranges Supply Voltages
A On-delayB Off-delayD One-shotF Flashing started by impulse
1 1 normally open contact 1 N.O.
S 0.75 s…1 h(A, D, F)
0.5 s…1 h (B)
U22 24 VUC110…240 V 50/60 Hz
700-FE A 3 T U23
FunctionAssembly of
ContactsTime Ranges Supply Voltages
A On-delayB Off-delayD One-shotE Fleeting off-delayF Flashing started by impulseL Pulse converter
3 1 changeover contact 1 C/O
T 0.05 s…10 h U23 24 … 48 VDC24…240 V 50/60 Hz
700-FE Y 2 Q U23
FunctionAssembly of
ContactsTime Ranges Supply Voltages
Y Star-Delta-Timing Relay 2 2 normally open contact 2 N.O.
Q 0.15 s…10 min U23 24…48 VDC24…240 V 50/60 Hz
8-16 Rockwell Automation
Bulletin 700-FE
8
Economy Timing RelaysProduct Selection
Multi-Function
Overall-width 17.5 mm according to DIN 43880
Description
Das Multi-Function Timing Relay 700-FEM includes 4 selectable functions:
(A) - On-delay(B) - Off-delay(D) - One-shot(F) - Flashing started by impulse
Multi-Time Setting Ranges0.5 s…1 h
(10s) 0.5…10 s(1mn) 0.05…1 min(10mn) 0.5…10 min(1h) 0.05…1 h
Multi-Time Setting Ranges0.05 s…10 h
(1s) 0.05…1 s(10s) 0.5…10 s(1mn) 0.05…1 min(10mn) 0.5…10 min(1h) 0.05…1 h(10h) 0.5…10 h
Supply VoltagesU22 110… 240 V, 50/60 Hz (A1/A2)
24 VUC (A3/A2)
Supply VoltagesU23 24… 48 VDC (A1/A2)
24… 240 V,50/60 Hz (A1/A2)
Cat. No. PQ Cat. No. PQ
700-FEM1RU22 1 —
— 700-FEM3TU23 1
A1/A2 orA3/A2U
Output t
LED
1518
L/+
N/-A2
A1/A3 15
18
A1/A2 orA3/A2
A1/B1 orA3/B1
U
Output t
LED
1518
L/+
N/-A2
A+/A3 15B1 S
18
S
A1/A2U
Output t
LED
151816
L/+
N/-A2
A1 15
18 16
A1/A2
A1/B1
U
S
Output t
LED
151618
L/+
N/-A2
A1 B1 S 15
18 16
A1/A2 orA3/A2U
Output t
LED
1518
L/+
N/-A2
A1/A3 15
18
A1/A2U
Ouput t
LED
151816
L/+
N/-A2
A1 15
18 16
A1/A2
151816
U
Output t t ttt
LED
L/+
N/-A2
A1 15
18 16
(A) On-delay (B) Off-delay
(D) One-shot (F) Flashing started by impulse
1 N.O. 1 N.O.
1 C/O 1 C/O
1 N.O. 1 N.O.
1 C/O1 C/O
LED U = green: Supply voltages available
LED Relays = orange: Output is energized
Bi-Colour LED: (only for 700-FE.3)
A1/A2 orA3/A2
1518
U
Ouput t t ttt
LED
L/+
N/-A2
A1/A3 15
18
PQ = Package Quantity
Rockwell Automation 8-17
Accessories - Page 8-19Specifications - Page 8-20Dimensions - Page 8-21
Bulletin 700-FE
8
Economy Timing RelaysProduct Selection
Single-FunctionOverall-width 17.5 mm according to DIN 43880
Description
Multi-Time Setting Ranges
0.75 s…1 h,(15s) 0.75…15 s(1mn) 0.05…1 min(8mn) 0.4…8 min(1h) 0.05…1 h
Multi-Time Setting Ranges
0.5 s…1 h(10s) 0.5…10 s(1mn) 0.05…1 min(10mn)0.5…10 min(1h) 0.05…1 h
Multi-Time Setting Ranges
0.05 s…10 h(1s) 0.05…1 s(10s) 0.5…10 s(1mn) 0.05…1 min(10mn) 0.5…10 min(1h) 0.05…1 h(10h) 0.5…10 h
Supply VoltagesU22 24 VUC (A3/A2)
110 … 240 V, 50/60 Hz (A1/A2)
Supply VoltagesU23 24 … 48 VDC (A1/A2)
24 … 240 V, 50/60 Hz(A1/A2)
Function Diagram / Connection Diagram Cat. No. PQ Cat. No. PQ Cat. No. PQ
(A) On-delayThe output contact changes state after the time delay is completed.
700-FEA1SU22 1 — —
— — 700-FEA3TU23 1
(B) Off-delayThe output contact changes state when switch „S“ is closed. When switch „S“ is opened, the time delay begins. After the time delay is completed, the contact returns to shelf state.
— 700-FEB1SU22 1 —
— — 700-FEB3TU23 1
(D) One-shotThe output contact changes state when the relay is energised, The out-put contact returns to shelf state when the time delay is completed.
700-FED1SU22 1 — —
— — 700-FED3TU23 1
(F) FlashingThe output contact changes state when the power is applied. At the end of the time delay, the output contact returns to shelf state. This cycle continues until the power is removed.
700-FEF1SU22 1 — —
— — 700-FEF3TU23 1
A1/A2 orA3/A2U
Output t
LED
1518
L/+
N/-A2
A1/A3 15
18
A1/A2U
Output t
LED
151816
L/+
N/-A2
A1 15
18 16
A1/A2 orA3/A2
A1/B1 orA3/B1
U
Output t
LED
1518
L/+
N/-A2
A+/A3 15B1 S
18
S
A1/A2
A1/B1
U
S
Output t
LED
151618
L/+
N/-A2
A1 B1 S 15
18 16
A1/A2 orA3/A2U
Output t
LED
1518
L/+
N/-A2
A1/A3 15
18
A1/A2U
Ouput t
LED
151816
L/+
N/-A2
A1 15
18 16
A1/A2 orA3/A2
1518
U
Ouput t t ttt
LED
L/+
N/-A2
A1/A3 15
18
A1/A2
151816
U
Output t t ttt
LED
L/+
N/-A2
A1 15
18 16
8-18 Rockwell Automation
Accessories - Page 8-19Specifications - Page 8-20Dimensions - Page 8-21
Bulletin 700-FE
8
Economy Timing RelaysProduct Selection / Accessories
Single-FunctionOverall-width 17.5 mm according to DIN 43880
➊ A voltage other than the supply voltage can be used for the impulse control.
Special FunctionOverall-width 17.5 mm according to DIN 43880
Accessories
Labelling Material
Description
Function Diagram / Connection Diagram Cat. No. PQ
(E) One-shotThe output contact changes state after closing and opening switch „S“. After the time delay is completed, the contact returns to shelf state.
700-FEE3TU23 1
(L) Pulse ConverterWhen switch „S“ is closed, the output contact changes state. When the time delay is completed, the contact returns to shelf state. The time „t“ is not influenced by the duration of the control pulse.
700-FEL3TU23 1
Description
Multi-Time Setting Ranges0.15 s…10 min
(3s) 0.15…3 s(10s) 0.5…10 s(1mn) 0.05…1 min(10mn) 0.5…10 min
Supply VoltagesU23 24…48 VDC (A1/A2)
24…240 V, 50/60 Hz (A1/A2)
Function Diagram/ Connection Diagram Cat. No. PQ
(Y) Star-Delta-Timing RelayWhen power is applied, the output contact (Y) changes state. After the time setting, the output contact (Y) returns to shelf state. After the fixed time (t), the output contact ∆ changes state. The output contact ∆ returns to shelf state after the power is removed.
700-FEY2QU23 1
Description Cat. No. PQ
Screw Adapterfor surface mounting according to drilling plan EN 50 002Width 22.5 mm
199-FSA 5
• Uniform labelling material for contactors, motor protection devices, timing relays and circuit breakers.For product information and ordering informations see chapter 3.
A1/A2
A1/B1
U
S
Output t
LED
1518
L/+
N/-A2
A1 15B1 S
➊
18 1616
A1/A2U
A1/B1
181615tt
S
Output
LED
L/+
N/-A2
A1 15B1 S
➊
18 16
A1/A2
17/18
U
tu = 50...65 ms
t
LED
17/28
L
NA2
A1
18
17
28
PQ = Package Quantity
Rockwell Automation 8-19
Specifications - Page 8-20Dimensions - Page 8-21
Bulletin 700-FE
8
Economy Timing RelaysSpecifications
Specifications
Time Characteristics (according to VDE 0435, Part 2021)
Setting Accuracy ±5% of the time range end value (tmax.)
Repeatability ±1% of the time range end value (tmax.)
Tolerance voltage: ± 0.01%/%∆Utemperature ± 0.25%/°C
voltage: ± 0.001%/%∆Utemperature: ± 0.025%/°C
Supply
Supply Voltages 24…48 VUC and 110…240VAC, 50/60 Hz 24…48 VDC and 24…240VAC, 50/60 Hz (dual voltage)
Voltage ToleranceAC DC
-15%/+10%-15%/+20%
Power Consumptionat 240 VAC [VA]at 24 VDC [W]
90.5
50.5
Time Energised 100%Reset Value [ms] 250 100Voltage Isolation [ms] — ≤30without reset (supply voltage)Cable Length of Supply Voltage Control [m] max. 100 max. 250
Pulse Control (B1)
Pulse Duration [ms] ≥250 ≥50 (AC), ≥30 (DC)Input Voltage same as supply voltage rangeInput Current 1 mACable Length max. 250 m without parallel load between B1 and A2
max. 50 m with load (<3 kΩ) between B1 and A2
Outputs
Contact Type Relays as normally open contact 1 Form C — SPDT contactSwitching Capacity Voltage: 250 VAC
Current Ith: 5 APower: 1250 VA
according to IEC 947-5-1:1 A/250 VAC (inductive load, AC 14)1 A/24 VDC (inductive load, DC 13)
Short-circuit Resistance 6 A gLLifespanmechanical [operations]
electrical [operations]
20 Mio.
0.4 Mio. at1 A/250 VAC, cos ϕ = 10.4 Mio. at 0.5 A/250 VAC, cos ϕ = 0.4
0.4 Mio. at 1 A/24 VDC, resistiveState Indication 1 LED 1 Bi-Colour LED (Supply; Relays)
8-20 Rockwell Automation
Product Selection - Page 8-17
Bulletin 700-FE
8
Economy Timing RelaysSpecifications
General Data
Insulation Characteristics 2 kVAC/50 Hz test voltage according to VDE 0435and 4 kV 1.2/50 µs surge voltage according to IEC 947-1 between all inputs and outputs
EMC Interference ImmunitySurge Capacity of Supply Voltage
BurstESD Discharge
Performance of following requirements:according to IEC 1000-4-5:level 3 (A1-A2) 110…240 VAC
according to IEC 1000-4-5: level 2 (A3-A2) 24 VUCaccording to IEC 1000-4-4: level 3according to IEC 1000-4-2: level 3
Performance of following requirementsaccording to IEC 1000-4-5: level 3
according to IEC 1000-4-4: level 3according to IEC 1000-4-2: level 3
EMC Emmission electromagnetical field according to EN 55 022: class BSafe Isolation according to VDE 106, Part 101Climatic Withstand 56 cycles (24 h) at 25…40°C and 95% rel. humidity according to IEC 68-2-30 and IEC 68-2-3Vibration Resistance [G] 4, in 3 axis at 10…500 Hz, test FC according to IEC 68-2-6Shock Resistance [G] 50, according to IEC 68-2-27Protection Class Enclosure: IP 40
Terminal: IP 20Weight [g] 60 60Approvals CE, UL Listed, C-UL Listed CE, UL Listed, C-UL Listed, Germanischer LloydAmbient TemperatureOpen [°C]Enclosed [°C]Storage [°C]
-25 … +60-25 … +45-40 … +85
Terminals Screw terminal M3 for Pozidrive No.1, Philips and slotted screws No. 2. Suitable for power screw driver. Rated tightening torque 0.8 Nm (max. 1.0 Nm)
For terminal cross-sections of 1 x 0.5 mm2 … 2 x 1.5 mm2 (solid) or 2 x 1.5 mm2 (stranded, flexible with sleeve), AWG 20…14.
Finger protection according to VDE 0106Mounting Front mounting; For snap-on mounting on DIN rail 35 mm or
screw fixing by adapter and 2 screws M4
Rockwell Automation 8-21
Product Selection - Page 8-17
Bulletin 700-FE
8
Economy Timing RelaysDimensions
Dimensions are shown in millimeters
17.5 7066
80 45
43
35
4.3
58 75
22.5 13
4.3 2
9
17 12
5.5
700-FE 199-FSA
8-22 Rockwell Automation
Product Selection - Page 8-17
Bulletin 700-HX
8
Digital Timing Relays
Table of ContentsDescription Page Description PageOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Type Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-24
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-24
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-25
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-27
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-28
Standards and Approvals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-28
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-28
Bulletin 700-HX Timing Relays
• Multi-Function8 functions selectable7 time settings selectable
• Flush Mounting or Plug-in
Rockwell Automation 8-23
Bulletin 700-HX
8
Digital Timing RelaysType Designation / Product Selection
Multi-Function
Multi-Function
➊ The digital timing relays Cat. No. 700-HX… is delivered with the mounting frame Cat. No. 700-HN130
700-HX 8 6 S A17
FunctionAssembly of
ContactsTime Ranges Supply Voltages
8 Multi-function timing relayswith reset function
(1) On-delay(with stop function)
(2) Off-delay(3) One-shot(4) Flashing started by pause
(with stop function)(5) On-delay
with pulse function(6) On-delay
time memory function(with stop function)
(7) Integratoron-delaywith sum memory
(8) Unequal repeat cyclestarted by pause(with stop function)
6 1 Changeover contact 1 C/O
S 0.05 s…9999 h A17 100 … 240 V 50/60 HzU24 24 VUC
Connection Diagram Time Ranges Supply Voltages Cat. No. PQ
0.05 s … 9999 h
divided in:
0.05 …9.999 s0.05 …99.99 s0.1 …999.9 s1 … 9999 s0.01 …99.99 min0.01 …99.99 h1 … 9999 h
100 … 240 V, 50/60 Hz ➊ 700-HX86SA17 1
24 VUC ➊ 700-HX86SU24 1+
S
8
5
6
7
1
2
3
4
_ U
R
S - Start signalR - Reset U - Supply Voltages
PQ = Package Quantity
8-24 Rockwell Automation
Accessories - Page 8-27Specifications - Page 8-28Dimensions - Page 8-28
Bulletin 700-HX
8
Digital Timing RelaysFunctional Description
Multi-Function
➊ Display shows either time elapsed (referred to here as „set timer up“) or time remaining („set timer down“)
No. Input / Output Function Chart Explanation1 On-Delay with Stop Function (Mode 1).
After feeding the input voltage (A1/A2) the relay picksup after a delay of t.
• Start signal — Holds time event until released
• Reset signal — Resets display when applied.Timing starts when released
2 Off-Delay (Mode 2).Input power must be applied continuously.
• Start signal — Application operates the outputrelay. Release (off) starts the timing event. Inputagain, operates relay (if timed out) and release(off) starts the timing event again
• Reset signal — Resets display when applied. Release has no effect. Start signal (off) neededfor timing event
3 One-shot (Mode 3).Input power must be applied continuously.
• Start signal — Momentary input, operates out-put relay and also start timing event. Releasehas no effect
• Reset signal — Resets display and releasesoutput relay (if energised) when applied.Release has no effect
4 Flashing Started by Pause with Stop Function(Mode 4).The output contact remains in the shelf state until thetime delay is completed. When the time delay is com-pleted, the contact changes state. This cycle contin-ues until the power is removed.
• Start signal — Holds either time event untilreleased
• Reset signal — Resets display and releasesoutput relay (if energised) when applied. Theequal on and off cycling begins with the outputrelay de-energised when released
Power (2-7)
Start signal (1-4)
Reset (1-3)
Output (6-8)
LCD display ➊
Set timer up
Set timer down
Tt1 t2 t1 + t2 = T
Power (2-7)
Start signal (1-4)
Reset (1-3)
Output (6-8)
LCD display ➊
Set timer up
Set timer down
T
Power (2-7)
Start signal (1-4)
Reset (1-3)
Output (6-8)
LCD display ➊
Set timer up
Set timer down
T
Power (2-7)
Start signal (1-4)
Reset (1-3)
Output (6-8)
LCD display ➊
Set timer up
Set timer down
t1 + t2 =TTT
t1 t2
Rockwell Automation 8-25
Accessories - Page 8-27Specifications - Page 8-28Dimensions - Page 8-28
Bulletin 700-HX
8
Digital Timing RelaysFunctional Description
➊ Display shows either time elapsed (referred to here as „set timer up“) or time remaining („set timer down“)
No. Input / Output Function Chart Explanation5 On-delay with Pulse Function (Mode 5).
The input power must be applied continuously.
• Start signal — Momentary input, starts the tim-ing event. Release has no effect. Relay operatesat end of the event
• Reset signal — Resets the display and the out-put relay (if energised) when power is applied.Start signal needed to start timing event
6 On-delay with Time Memory Function,with Stop Function (Mode 6).The input power must be applied continuously. How-ever, if there is a loss of power, time is held until poweris reapplied.
• Start signal — Holds timed event until released
• Reset signal — Resets the display and the relay(if energised) when applied. Starts timing eventwhen released
7 IntegratorOn-delay with Sum Memory (Mode 7).The input power must be applied continuously.
• Start signal — Input starts time delay but con-tinues. only as long as the signal is maintained.Release does not reset. Delay continues (inte-grates) with input
• Reset signal — Resets the display and the relay(if energised) when applied
8 Unequal Repeat Cycle Started by Pausewith Stop Function (Mode 8).Input power starts unequal cycling.
• Start signal — Holds on or off cycling event untilreleased
• Reset signal — Resets the display and the relay(if energised) when applied. Unequal cyclingbegins again with the output relay de-energisedwhen released
Power (2-7)
Start signal (1-4)
Reset (1-3)
Output (6-8)
LCD display ➊
set timer up
set timer down
T
Power (2-7)
Start signal (1-4)
Reset (1-3)
Output (6-8)
LCD display ➊
set timer up
set timer down
t1 + t2 =Tt1 t2t1 t2
Power (2-7)
Start signal (1-4)
Reset (1-3)
Output (6-8)
LLCD display ➊
set timer up
set timer down
t1 + t2 = Tt1 t2T
Power (2-7)
Start signal (1-4)
Reset (1-3)
Output (6-8)
LCD display ➊
set timer up
set timer down
t1+t2=ToffTonToff t1 t2
8-26 Rockwell Automation
Accessories - Page 8-27Specifications - Page 8-28Dimensions - Page 8-28
Bulletin 700-HX
8
Digital Timing RelaysAccessories
Accessories
Description Cat. No. PQ
Screw Terminal Tube Base Socket8-polesMounting on top hat rail or with 2 fixing screws
Note: The screw terminal tube base socket Cat. No. 700-HN202 can also be used
700-HN100 10
Speciality Socket8-poles8-pin backwired socket with soldered terminalsFor front mounting
700-HN108 10
Frame AdapterFor front mountingAs spare part
700-HN130 1
Protective CoverHelps prevent tampering of timing and mode settings.Provides a degree of protection against splash water and dirt from entering the front of the relay
700-HN132 1
PQ = Package Quantity
Rockwell Automation 8-27
Product Selection - Page 8-24
Bulletin 700-HX
8
Digital Timing RelaysSpecifications / Dimensions
Specifications
Dimensions
Time characteristics (according to VDE 0435, Part 2021)
Setting AccuracyFinal scale value: 0…+40%Initial scale value: 0…-40%
Repeatability ± 0.03%, ± 50 msSetting Possibilities ± 1 unit on a 4-digit displayTolerances ± 0.03%
Supply
Supply Voltages 24 VUC or 100…240VAC, 50/60 HzVoltage Tolerance -20% / +10% (DC), -15% / +10% (AC)Power Consumptionat 24 VDC [W]at 240 VAC [VA]
0.81.5
Time Energised 100%Reset ValueReset [ms]Start Signal [ms]
50020
Outputs
Switching Capacity Voltage: 250 VACCurrent Ith: 5 A
1.5 A/120 VAC (inductive load)0.75 A/240 VAC (inductive load)
5 A/30 VDC (inductive load)Lifespanmechanical 10 Mio. operationsSwitching Frequency 3600 operations/hState Indication LCD display
General DataInsulation Characteristics 1 kVAC between inputs and outputs
2 kVAC between coil and inputs and outputs
Protection Class Screw terminal tube base socket: IP 20 according to IEC 947-1
Approvals CE, UL Listed, CSAAmbient TemperatureOperation [°C]Storage [°C]
-10 … +55-25 … +65
Mounting Front mounting with frame adapter or socket mounting
Contact Material AgCdO
45(1-49/64)
20
(9/32)
(3-47/64)
1.5(1/64) (2-27/32)
Panel
95
72.5
(1-2
9/32
)48
SQ
.
(47/64)18.5
1.0
(1/32)
(2)
50.7
SQ
1. Panel / sheet metal / door) (31/32)24
(2-1
/4)
57
(1-3/8)35
(1-1
/4)
32(1-3
/4)
44.5
SQ
.
Protective Cover
Digital Timing Relays
Frame adapter
Connector plug
8-28 Rockwell Automation
Product Selection - Page 8-24
Bulletin 700-HR
8
Multi-Range Dial Timing Relays
Table of ContentsDescription Page Description PageOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Type Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-30
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-30
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-31
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-33
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-34
Standards and Approvals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-34
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-34
Bulletin 700-HR Multi-Range Dial Timing Relays
• Multi-Function4 functions selectable12 time settings selectable
• Single-Functions2 functions selectable12 time settings selectable
• Flush- or Plug-in Mounting
Rockwell Automation 8-29
Bulletin 700-HR
8
Multi-Range Dial Timing RelaysType Designation / Product Selection
Multi-Function
Single-Functions
Multi-Function and Single-Functions
A frame adapter for front mounting is available as option. See page 8-27
700-HR 5 2 T Z24
FunctionAssembly of
ContactsTime Ranges Supply Voltages
5 Multi-function timing relays four single-functions
(PO) On-delay(SF) Off-delay(OS) One-shot(FL) Flashing started by impulse
2 2 changeover contact 2 C/O T 0.05 s…60h
U24 24VUCA17 100…240V 50/60 Hz
700-HRM 1 2 T U24
FunctionAssembly of
ContactsTime Ranges Supply Voltages
1 On-delay 2 2 changeover contact 2 C/O
T 0.05 s…60h U24 24VUCA17 100…240V 50/60 Hz
700-HRC 1 2 T U24
FunctionAssembly of
ContactsTime Ranges Supply Voltages
1 On-delay 2 2 changeover contact 2 C/O
(1 instantaneous contact)
T 0.05 s…60h U24 24VUCA17 100…240V 50/60 Hz
Function Time Ranges Supply Voltages Cat. No. PQ
0.05 s … 60 h
24 VUC 700-HR52TU24 1
100 … 240 V, 50/60 Hz 700-HR52TA17 1
On-delay2 changeover contacts
0.05 s … 60 h24 VUC 700-HRM12TU24
1100 … 240 V, 50/60 Hz 700-HRM12TA17
On-delay1 changeover and 1 instantaneous contact
0.05 s … 60 h24 VUC 700-HRC12TU24
1100 … 240 V, 50/60 Hz 700-HRC12TA17
On-delay
Off-delay
One-shot
Flashing started by impulse
PO
SF
OS
FL
PQ = Package Quantity
8-30 Rockwell Automation
Accessories - Page 8-33Specifications - Page 8-34Dimensions - Page 8-34
Bulletin 700-HR
8
Multi-Range Dial Timing RelaysFunctional Description
Type HR
R = ResetS = Start signalG = Gate signal
24
32
34
A3111
A
14
12
2221
+
1 2
RS
G (S)
(S)
(S)
(G)(R)
(G)(R)(G)(R)
(G)(R)
(S)
A2
A1
A2
A1
A2
A1
OS
12 14 21 32 34
11 22 24 31
SF
12 14 21 32 34
11 22 24 31
FL
12 14 21 32 34
11 22 24 3131242211
3432211412
A1
A2
PO
_ U
2
1A
A
12 14 22 24
11 21
TCTC
21
12
14
A
11 21
A
24
22
+_ U
IC = Instantaneous contactTC = Timed contactU = Supply Voltages
Type HRCType HRM
2
1A
A
12 14 22 24
11 21
TCIC
21
12
14
A
11 21
A
24
22
+_ U
Rockwell Automation 8-31
Accessories - Page 8-33Specifications - Page 8-34Dimensions - Page 8-34
Bulletin 700-HR
8
Multi-Range Dial Timing RelaysFunctional Description
Type HROn-delay with Pulse Function (PO).Input power must be applied continuously.When a start signal is applied the timing cycle begins.The output contact changes state after the time delay is com-pleted. The contacts will return to their shelf state when a resetsignal is applied or power is removed.• The start signal can be either momentary or maintained• Reapplying a start signal during the timing cycle will have no
effect on the time delay
Off-delay (SF).Input power must be applied continuously.When a start signal is applied the output contacts change stateimmediately. The output contact changes state after the timedelay is completed. When the start signal is removed the timingcycle begins. The output contacts will return to their shelf stateonce the time delay is completed. Reset will occur when a resetsignal is applied or power is removed.• The start signal must be maintained until the timing cycle
begins• If the start signal is reapplied after the timing cycle has
begun, the time delay resets and will not begin until the startsignal is removed
One-shot (OS).Input power must be applied continuously.When a start signal is applied the output contacts change stateimmediately and the timing cycle begins. The output contactsreturn to their shelf state once the time delay is completed. Resetwill occur when a reset signal is applied or power is removed.• The start signal can be either momentary or maintained• Reapplying a start signal during the timing cycle will have no
effect on the time delay
• Reapplying a start signal after the time delay is completedwill start a new timing cycle (no reset is required
Flashing Started by Pause, Pulse Controlled) (FL).Input power must be applied continuously.When a start signal is applied the „off timing cycle“ begins, butthe output contacts remain in the shelf state. When the time delayis completed the output contacts change state and the next „ontiming cycle“ begins. When this time delay is completed the out-put contacts return to their shelf state. This sequence will repeatuntil a reset signal is applied or power is removed.• The start signal can be either momentary or maintained• Reapplying a start signal during the timing cycle will have no
effect on the time delay
Type HRMOn-delay, 2 C/OWhen power is applied the output contacts change state and thetiming cycle begins. The timed out contacts change state afterthe time delay is completed. All contacts will return to their shelfstate when power is removed.
Type HRCOn-delay 2 C/O, 1 of it is an instantaneous contactWhen power is applied the instantaneous output contactschange state and the timing cycle begins. The timed out contactschange state after the time delay is completed. All contacts willreturn to their shelf state when power is removed.
Note- If the output contact S - bridged, the timing cycle begins
when supply voltage is applied (exception: Off-Delay (SF)
- Closing the interrupting signal G - stops the time cycle forthe time until the interruption signal G is opened again
102
2 6
2 7
2 5
119
31
118
1 4
NC
NOTC
S
R
G
T T t X T_t
T
t
T
T_tXt TT
G
R
S
TC NO
NC
41
8 11
1 3
9 11
52
72
62
2 10
t
T
T_tXtTT
G
R
S
TC NO
NC
41
8 11
1 3
9 11
52
72
62
2 10
T TT t
T
T_t XtTT
G
R
S
TCNO
NC
41
8 11
1 3
9 11
52
72
62
2 10
NC
NOTC
72 T
68
31
58
1 4
TCNC
NO
NO
NCIC
72
T
31
41
68
8 5
Accessories - Page 8-33Specifications - Page 8-34Dimensions - Page 8-34
8-32 Rockwell Automation
Bulletin 700-HR
8
Multi-Range Dial Timing RelaysAccessories
Accessories
Description Cat. No. PQ
Screw Terminal Tube Base Socket8-poles.Mounting on top hat rail or with 2 fixing screws.
Note: The screw terminal tube base socket Cat. No. 700-HN202 can also be used.
700-HN100 10
Screw Terminal Tube Base Socket11-poles.Mounting on top hat rail or with 2 fixing screws.
Note: The screw terminal tube base socket Cat. No. 700-HN203 can also be used.
700-HN101 10
Speciality Socket8-poles for type HRM, HRC.8-pin backwired socket with soldered terminals.For front mounting.
700-HN108 10
Speciality Socket11-poles for type HR.11-pin backwired socket with soldered terminals.For front mounting.
700-HN129 10
Frame AdapterFor front mounting.
700-HN130 1
Protective CoverHelps prevent tampering of timing and mode settings.Provides a degree of protection against splash water and dirt from entering the front of the relay.
700-HN132 1
PQ = Package Quantity
Rockwell Automation 8-33
Product Selection - Page 8-30
Bulletin 700-HR
8
Multi-Range Dial Timing RelaysSpecifications / Dimensions
Specifications
Dimensions
Time characteristics (according to VDE 0435, Part 2021)Setting Accuracy ±5% of the scaleRepeatability ±0.03%, $10 msTolerances ±0.5%
SupplySupply Voltages 24 VUC or 100…240VAC, 50/60 HzVoltage Tolerance -20% / +10% (DC), -15% / +10% (AC)Power consumption 1 W at 24 VDC, 10 VA at 240 VACTime Energised 100%Reset Value 100 ms
OutputsSwitching Capacity Voltage: 250 VAC
Current Ith: 5 A1.5 A/120 VAC (inductive load)
0.75 A/240 VAC (inductive load)5 A/30 VDC (inductive load)
Lifespanmechanical 10 Mio. operationsSwitching Frequency 1800 operations/hState Indication 2 LED
General DataInsulation Characteristics
1.5 kVAC between inputs and outputs respectively between coil and
inputs and outputs
Protection ClassScrew terminal tube base socket:
IP 20 according to IEC 947-1Approvals CE, UL Listed, CSAAmbient TemperatureOperation [°C]Storage [°C]
-30 … +55-55 … +85
Mounting Front mounting with frame adapter or socket mounting
Contact Material AgCdO
48
(1-57/6448
6(1/4)
(3-7/32)15
(19/32)(2-1/16)
81.5
52.3
(1-57/64)
UnitRange
6
5
32
1
0 hrs
Power
UpMode
PO
4
(1-25/32)45
45
(1-25/32)
Multi-range dial timing relay Hole cutout
8-34 Rockwell Automation
Product Selection - Page 8-30
Bulletin 700-HA
8
Plug-in Style Relays
Table of ContentsDescription Page Description PageOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Type Designation / Contact Ratings . . . . . . . . . . . . . . . . . . . . 8-36
Product Selection
Relays with 2 or 3 Changeover Contacts . . . . . . . . . . . . . . . . 8-37
Base-Socket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-37Multi-Range Time and Surge Suppressor Modules . . . . . . . . 8-38
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-38
Specifications
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-39
Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-39
Standards and Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-39
Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-40
Mounting Position / Switching Diagrams . . . . . . . . . . . . . . . . .8-42
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-43
Bulletin 700-HA Plug-in Style Relays
• 2 or 3 Changeover Contacts• Tube Base Socket Mounting• Multi-Range Time and
Surge Suppressor Modules
Rockwell Automation 8-35
Bulletin 700-HA
8
Plug-in Style Relays Type Designation / Contact Ratings
Switching Capacities
Minimum Switching CapacitiesUnder normal industrial operating conditions, the minimal switching capacity of the Relay Cat. No. 700-HA is:
The Following Operating Conditions are not "normal":• Rare switching (can lead to surface oxidation on contacts)• Very dirty environment (e.g. dust, flour, water, micro fibre, …)• Special atmosphere and gases (e.g. in the chemical industry)The above mentioned minimum values can not be guaranteed at such operating conditions.
700-HA 3 3 Z2 - 3 - 4
Relays Bulletin Coil Control Voltage
Contact Type3 - Standard contact AgNiB - Twin contacts AgNiX - Twin contacts AgNi, 10 µm gold plated
No. of Changeover Switches2 - 2 Changeover contacts3 - 3 Changeover contacts
DC
Z06 - 6VDCZ12 - 12 VDCZ24 - 24 VDCZ36 - 36 VDCZ48 - 48 VDCZ60 - 60 VDCZ1 - 110 VDCZ01 - 125 VDCZ3 - 140 VDCZ2 - 220 VDC
ACA06 - 6 VAC 50/60HzA12 - 12 VAC 50/60HzA24 - 24 VAC 50/60HzA36 - 36 VAC 50/60HzA48 - 48 VAC 50/60HzA11 - 110 VAC 50/60HzA1 - 120 VAC 50/60HzA03 - 230 VAC 50/60HzA2 - 240 VAC 50/60HzA27 - 277 VAC 50/60Hz
Options
- Blank No special features- 3 Push to test & manual overide- 4 Pilot light (not available for "A27" coil)- 4L Pilot light (for use with coil voltages "A2")- 3- 4 Push to test & manual overide W / pilot light-3- 4L Push to test & manual overide W / pilot light
(for use with coil voltages "A2")-99 Bulk pack (10 pieces)
Remarks:
< 80 V with LED> 80 V mit neon lamp
Mechanical switching position indications included in scope of delivery as standard
Voltage
AC 1 at 230 V
StandardContact
AgNi
Twin Contact
AgNi
Twin Contactgold plated
AgNi + 10 µmAu
Type designation 700-HA3… 700-HAB… 700-HAX…Rated current [A]max. current at make [A]
10≤ 20
4≤ 10
4≤ 10
Voltage
DC 1
1 StandardContact
2 StandardContactsin Serie
3 StandardContactsin Serie
Type designation 700-HA3… 700-HA3… 700-HA3…[V] [A] [A] [A]24 6 6 648 1 6 660 0.75 6 6
125 0.25 0.8 2.5
Voltage
DC
StandardContact
AgNi
Twin ContactAgNi
Twin Contactgold platedAgNi + 10
µmAu
Type designation 700-HA3… 700-HAB… 700-HAX…[V] [mA] [mA] [mA]0.1 — — 110 100 20 112 80 15 124 40 10 148 20 5 1
DC
Current
StandardContact
AgNi
Twin Contact
AgNi
Twin Contact
gold platedAgNi + 10 µmAu
Type designation 700-HA3… 700-HAB… 700-HAX…[mA] [V] [V] [V]
1 — — 0.15 230 48 0.1
10 110 24 0.115 60 12 0.120 48 10 0.150 20
8-36 Rockwell Automation
Bulletin 700-HA
8
Plug-in Style RelaysProduct Selection
Plug-in Style RelaysWith 2 or 3 Changeover Contacts
• Relay for socket mounting
• High contact reliability
• Large contact area made of silver nickel (AgNi) for high peak-current at make
• Standard version with manual operator and mechanical switching position indication
• Version with additional LED
• Marking labeling possibility with legend plate of the terminal blocks
• UL and CSA approval for standard relays
• Developed and manufactured according to DIN IEC 255 Part 1-00/VDE 0435 Part 201 Plug-in style Relay
Base Socket
Description Wiring Diagrams [V] Cat. No. PQ
700-HA32…• Mechanical switching position indication• 8-poles• 2 changeover contacts
12 V50/60Hz24 V50/60Hz48 V50/60Hz
110 V50/60Hz230 V50/60Hz240 V50/60Hz
700-HA32A12-3700-HA32A24-3700-HA32A48-3700-HA32A11-3700-HA32A03-3700-HA32A2-3
112 VDC24 VDC48 VDC
110 VDC
700-HA32Z12-3700-HA32Z24-3700-HA32Z48-3700-HA32Z1-3
• LED and mechanical switching position indication
• 8-poles• 2 changeover contacts
24 V50/60Hz110 V50/60Hz230 V50/60Hz240 V50/60Hz
700-HA32A24-3-4700-HA32A11-3-4700-HA32A03-3-4700-HA32A2-3-4
24 VDC 700-HA32Z24-3-4
700-HA33…
• Mechanical switching position indication
• 11-poles
• 3 changeover contacts
24 V50/60Hz48 V50/60Hz
110 V50/60Hz230 V50/60Hz240 V50/60Hz
700-HA33A24-3700-HA33A48-3700-HA33A11-3700-HA33A03-3700-HA33A2-3 1
12 VDC24 VDC48 VDC
110 VDC
700-HA33Z12-3700-HA33Z24-3700-HA33Z48-3700-HA33Z1-3
• LED and mechanical switching position indication
• 11-poles• 3 changeover contacts
24 V50/60Hz110 V50/60Hz230 V50/60Hz240 V50/60Hz
700-HA33A24-3-4700-HA33A11-3-4700-HA33A03-3-4700-HA33A2-3-4
1
24 VDC 700-HA33Z24-3-4
• Special version with twin contacts on request• Special version with gold contacts on request• Special control voltages on request (possible control voltages 6 … 240 V 50/60 Hz, 6 … 220 VDC)
Description For Relays Cat. No. PQ
• Snap-on mounting on DIN rail or with 2 fixing screws• Can be used with or without timing module • Can be used with or without surge suppression module
8-poles 700-HA32… 700-HN202
10
11-poles 700-HA33… 700-HN203
• Snap-on mounting on DIN rail or with 2 fixing screw8-poles 700-HA32… 700-HN100
10
11-poles 700-HA33… 700-HN101
A1
A2 11
1412
21
2422
A1
A2 11
1412
21
2422
31
3432
Rockwell Automation 8-37
Accessories - Page 8-38Specifications - Page 8-39Dimensions - Page 8-43
Bulletin 700-HA
8
Plug-in Style Relays Product Selection / Accessories
Multi-Function Multi Range Time Module and Surge Suppressor Modules
➊ (UC = AC 50/60 Hz and DC)
Accessories
Labelling Material
Description Supply Voltage Cat. No. PQ
Multi-Function Multi Range Time Module• 8 functions selectable• 8 available time ranges from 0.1 s … 240 h• Can be combined with industrial relays (socket 700-HN202 or 700-HN203)• Connectable multi-voltage 24…240 VAC or VDC
(Functional description see page 8-40)
24 … 240 VUC ➊
700-HT1
20
12 VDC 700-HT2
Diode Surge Suppressor• For base socket 700-HN202 or 700-HN203
6…250 VDC 700-HSMD 20
LED Surge Suppressor Module• For base socket 700-HN202 or 700-HN203
24 VDC60 … 130 VDC48 VUC ➊110 … 230 VAC
700-HLT1700-HLT2700-HLT3700-HLT4 20
RC Suppressor Module• For base socket 700-HN202 or 700-HN203
24 … 48 VAC110 … 230 VAC
700-HSM1700-HSM2
MOV Suppressor Module• For base socket 700-HN202 or 700-HN203
24 VAC24 … 30 VDC
700-HSV120
220 … 240 VAC220 … 300 VDC
700-HSV2
Description Cat. No. PQ
Retainer Clip• For base socket
700-HN151 100
Label with Holder• For base socket 700-HN100 and 700-HN101
700-HL1 10
• Uniform labelling material for contactors, motor protection devices, timing relays and circuit breakers.For product information and ordering informations see chapter 3.
PQ = Package Quantity
8-38 Rockwell Automation
Product Selection - Page 8-37
Bulletin 700-HA
8
Plug-in Style RelaysSpecifications
Plug-in Style Relay Multi-Function Multi Range Time Module
Plug-in Relay Base Socket
Weights
Standards and Approvals
General DataTest VoltageCoil / contact [kV]Contact / contact [kV]open contact [kV]
2.5 / 50 Hz2.5 / 50 Hz1.5 / 50 Hz
Ambient temperature [oC]
[oC]
-25 … +40 (AC)-25 … +60 (DC)
Insulating Resistance [Ω] > 109
Operating LimitsAC 50 Hz [Us]AC 60 Hz [Us]DC [Us]
0.8 … 1.10.85 … 1.10.8 … 1.1
Power ConsumptionPick-up capacityRated capacity
50 Hz [VA]—2.5
DC [W]0.71.5
Maximum Switching delayApplying [ms]Delay time [ms]
AC 1215
DC1010
Contact DataContact Material AgNiCreep and Air Distance acc. to VDE 0110 b/2.79, C 250Distances of Opened Contacts > 0.4 mmRated Contact Current [A] 10Electrical Lifespanwith rated loan [operations] 100 000Max. No. of Switching Actuationswith max. loadwith light load
1 000 operations / h 20 operations / s
Mechanical Lifespan > 20 x 106 operationsMax. No. of Operations (mechanical AC/DC = 20 / s
Vibration Resistance30-100 Hz [g]
[g]> 5 (N.O. contact)> 2 (N.C. contact)
Admissible Fusequick-acting (D) [A]time-lag (DT) [A]
1010
DC-CoilCold coil, ambient temperature 20°CVoltage [V] Current [mA] Inductive Resistance [Ω] ± 10%
12 125 9624 63 38460 25 2 400
110 14 7 660220 7.2 30 630
AC-CoilCold coil, ambient temperature 20°C
Voltage [V]Current [mA]
50HzInductive Resistance [Ω] ± 10%
24 107 7460 43 474
110/115 23 1 710230 17 7 500
Operating LimitsAC 50 / 60 Hz [Us] 0.85 … 1.1DC [Us] 0.85 … 1.1Max. current consumption [mA] 15
Mounting Position anywayConnections captively combined slotted-
Philips screws (M3 + Philips size 1),
opened at deliveryTerminal Cross Sections [mm2] max. 2x1.5 with sleeveTightening Torque [Nm] 0.6
Creep and Air Distance according VDE 0110 b/2.79, C 250
Contact Load AC 1IEC 400 VAC [A]CSA, UL-recognized 300 VAC [A]
1010
Test VoltageConnection / connection [kV]Connection / grounding [kV]
2.5 / 50 Hz2.5 / 50 Hz
Ambient temperature [oC (oF)] -25 … +50 (-13 … 122)
Protection Class IP40
Tube Base Socket700-HN202 [g]700-HN203 [g]700-HN100 [g]700-HN101 [g]
60606060
Tube Base Relay700-HA32… [g]700-HA33… [g]
8585
Multi-Function Multi Range Time Module700-HT1 [g] 15
Diode Surge Suppressor700-MSMD [g] 12RC Suppressor Module700-MSM.. [g] 12Label with Holder700-HL1 [g] 5Retainer Clip700-HN151 [g] 5
ApprovalsCE, UL Listed,
UL Recognized, CSA
Rockwell Automation 8-39
Product Selection - Page 8-37
Bulletin 700-HA
8
Plug-in Style Relays Functional Description
Multi-Function Multi Range Time Module
Setting of the 8 Selectable Functions with the Sliding Switch
Function Var. Switch Position
On-delay 1
On energisation 2
Flashing started by impulse 3
Flashing started by pause 4
Off-delay 5
Pulse converting 6
On de-energisation 7
On-delay with impulse control 8
Setting of the 8 Available Time Ranges with the Sliding Switch
Time Ranges Time Switch Position
0.1 … 1 s 1s
1 … 10s 10s
0.1 … 1 min 1m
1 … 10min 10m
0.1 … 1 h 1h
1 … 10h 10h
2.5 … 24h 24h
25 … 240h 240h
User friendly setting of the Function andtime range required by means of a screwdriver or ballpoint pen.
8-40 Rockwell Automation
Product Selection - Page 8-37
Bulletin 700-HA
8
Plug-in Style RelaysFunctional Description
Multi-Function Multi Range Time Module
Descriptions of the Time Functions
Functional Sequence Wiring Diagrams Var. Function
1 On-DelayAfter connection of the input voltage (A1/A2) the relay picks up after a delay of t.
2
On EnergisationAfter connection of the input voltage (A1/A2), the relay is in working condition for the duration of t. Distribution voltage has to be kept longer than the preset time t to fulfill this action completely. That‘s why this function can also be used to shorten pulse duration.
3
Flashing Started by ImpulseAfter connection of the input voltage (A1/A2), the relay is in working condition for the duration of t1. After t1 the relay is set to quiescent condition for a period of t2. This is subsequently followed by further cycles until cutting off the supply voltage.t1 = t2 = 50% of t
4
Flashing Started by PauseAfter connection of the input voltage (A1/A2), the relay is in quiescent condition for the duration of t1. After t1 the relay is set to working condition for a period of t2. This is sub-sequently followed by further cycles until cutting off the supply voltage.t1 = t2 = 50% of t
5
Off-delayWhen closing the control contact at the terminals B1 the relay picks up. It is released after opening the control contact with a delay of t. Minimum duration for the control pulse is 25 ms.If the control contact B1 is closed again before delay time t, the expired duration is can-celled and restarts from 0 at reopening.
6
Pulse ConverterThe distribution voltage(A1/A2) must be applied continuously. When closing the control contact at the terminals B1 the relay is in working condition for the duration of t. The period of t is independent of the control pulse duration. Minimum duration of the control pulse is 25 ms.The control contact B1 can be switched any way during time t.A further cycle can only be started, after the current one is completed.That‘s why this function can also be used to shorten pulse duration.
7
On De-energisationAfter opening the control contact at the terminals B1 the relay is in working condition for the duration of t. Minimum duration of control signal: 25 ms. Until period t has elapsed completely reopening the control contact has no effect. That‘s why this func-tion also can be used to prolong a break.
8 On-delay with Impulse ControlAfter closing the control contact the relay closes with a delay of t.
A1/A2LED (U)
LED (R)
Rel.
t
A1
A2 11
1412
21
2422
31
3432
A1/A2LED (U)
LED (R)
Rel.
t
A1
A2 11
1412
21
2422
31
3432
A1/A2LED (U)
LED (R)
Rel.
t 1 t 2
Tt 1=t 2 = 50% T
A1
A2 11
1412
21
2422
31
3432
A1/A2LED (U)
LED (R)
Rel.
t 1 t 2
Tt 1=t 2 = 50% T
A1
A2 11
1412
21
2422
31
3432
A1/A2LED (U)
B1
t
LED (R)
Rel.
A1+
A2-11
1412
21
2422
31
3432
A1/A2LED (U)
B1
t
LED (R)
Rel.
A1+
A2-11
1412
21
2422
31
3432
A1/A2LED (U)
B1
t
LED (R)
Rel.
A1+
A2-11
1412
21
2422
31
3432
A1/A2LED (U)
B1
t
LED (R)
Rel.
A1+
A2-11
1412
21
2422
31
3432
Rockwell Automation 8-41
Product Selection - Page 8-37
Bulletin 700-HA
8
Plug-in Style Relays Mounting Position / Switching Diagrams
Mounting Position 700-HA
Wiring DiagramsRelay Base-Socket Base-Socket Relay700-HA32… 700-HN202 700-HN100 View on pins
Relay Base-Socket Base-Socket Relay700-HA33… 700-HN203 700-HN101 View on pins
The functions of the Bulletin 700-HA relay are not influenced by the mounting position. When wall or overhead mounted with strong vibrations, the usage of Bulletin 700-HN151 retainer clips is recommended.
The Bulletin 700-HT1 time module is protected against dropout by means of limit stop.
360˚360˚
A1
A2 11
1412
21
2422
7
624
522
412
314
8 1 2A2 21 11 A1+
7-A2
6
72
3
1
412
522
11
14
A1 A2
24
821
17
624 5
22412
314
82
A221 11
A1
A1
A2 11
1412
21
2422
31
3432
10
934
832
724
522
314
412
10 11 6 2-A2 A2 31 21 11 A1+
1
1131
9
2
3
522
724
14
A1 A2
34
111
412
832
621
10
2111
10
9
832 7
24621
522
34
A231 11
412
A1
314
8-42 Rockwell Automation
Product Selection - Page 8-37
Bulletin 700-HA
8
Plug-in Style RelaysDimensions
Plug-in Style Relays Dimensions are shown in millimeters (inches)700-HA32…, 8-poles 700-HA33…, 11-polesPluggable in Bulletin 700-HN202 base socket, Pluggable in Bulletin 700-HN203 base socket,700-HN100 700-HN101
Time Module 700-HT1Pluggable in Bulletin700-HN202 and 700-HN203 base socket
35 (1-25/64)59
(2-
21/6
4)
12 (
15/3
2)
35 (
1-25
/64)
9 (2
3/64
) 35 (1-25/64)
59 (
2-21
/64)
12 (
15/3
2)
35 (
1-25
/64)
9 (2
3/64
)
35 12
7
4716
59.
5
Rockwell Automation 8-43
Product Selection - Page 8-37
Bulletin 700-HA
8
Plug-in Style Relays Dimensions
Plug-in Base Dimensions are shown in millimeters (inches)700-HN202, 8 poles 700-HN203, 11 poleswith Bulletin 700-HN151 retainer clip with Bulletin 700-HN151 retainer clipsuitable for Bulletin 700-HA32…relays suitable for Bulletin 700-HA33…relays
700-HN100, 8 poles 700-HN101, 11 poleswith Bulletin 700-HN151 retainer clip with Bulletin 700-HN151 retainer clipsuitable for Bulletin 700-HA32…relays suitable for Bulletin 700-HA33…relays
75 (
2-61
/64)
38 (1-1/2)
DIN
4627
7
26 (1-1/32)
34
9
-A2 A1+31A2 21
10
8 7 5 3 4
32 24 22 14 12
11
10 11 6 1 2
75 (
2-61
/64)
38 (1-1/2)
DIN
4627
7
26 (1-1/32)
122224
6 45
-A2 A1+
14
21
7
3
A2 11
7 8 1 2
DIN
4627
7
12
222124
32
8
6
4
57
-A2 A1+
34 14
31 11
9
10
1
2
3
65 (
2-9/
16)
38 (1-1/2) 27 (1-1/16)
10 (
25/6
4)
11
24
22 12
14
6
5 4
3
-A2
21 11
A1+
7
8 1
2
65 (
2-9/
16)
38 (1-1/2)
DIN
4627
7
27 (1-1/16)
10 (
25/6
4)
8-44 Rockwell Automation
Product Selection - Page 8-37
Bulletin 700-H
8
Plug-in Style Relays
Table of ContentsDescription Page Description PageOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Product Selection
Type HC - Miniature Square Base Relays, 1 and 5 A. . . . . . . 8-46
Type HF - Miniature Square Base Relays, 10 A . . . . . . . . . . . 8-46
Type HK - Slim Line Relays, 5 and 10 A. . . . . . . . . . . . . . . . . 8-47
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-48
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-49
Standards and Approvals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-49
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-50
Bulletin 700-H Plug-in Style Relays
• 1, 2 or 4 Changeover Contacts• Socket Mounting
Rockwell Automation 8-45
Bulletin 700-H
8
Plug-in Style RelaysProduct Selection
Miniature Square Base Relays Type HC with Blade Terminals
Miniature Square Base Relays Type HF with Quick Connect Solder Terminals
➊ Manual operator option: Add suffix (-1) to the selected HC relay Cat. No.➋ Pilot light option: Add suffix (-4) to the selected HC relay Cat. No.
except for the 240 V AC units, add (-4L)➌ Manual operator and pilot light option: Add suffix (-1-4) to the selected HC relay Cat. No.
Wiring Diagrams(International)
Description Contact Rating Coil VoltageCat. No.➊ ➋ ➌
PQ
• 4 changeover contacts
• Twin contacts:bifurcated gold overlay, Ag
1 A
24 VDC 700-HC54Z24
124 VAC 700-HC54A24
120 VAC 700-HC54A1
• 4 changeover contacts
• Contacts:AgCdO
5A(C300)
24 VAC 700-HC24A24
1
120 VAC 700-HC24A1
240 VAC 700-HC24A2
24 VDC 700-HC24Z24
110 VDC 700-HC24Z1
Wiring Diagrams(International)
Description Contact Rating Coil VoltageCat. No.➊ ➋ ➌
PQ
• 2 changeover contacts
• Contacts:AgCdO
10 A
24 VAC 700-HF32A24
1
120 VAC 700-HF32A1
240 VAC 700-HF32A2
24 VDC 700-HF32Z24
110 VDC 700-HF32Z1
• 4 changeover contacts
• Contacts:AgCdO
10 A
24 VAC 700-HF34A24
1
120 VAC 700-HF34A1
240 VAC 700-HF34A2
24 VDC 700-HF34Z24
110 VDC 700-HF34Z1
12 22 32 42
11
14 24
21 31
34 44
41
A1 A2
– +U
Screw terminal socket
700-HN103
12 2212
14 24
22
11
14 24
21
2A1 A2A1 A
+U_
Screw terminal socket
700-HN116
12 22 32 42
11
14 24
21 31
34 44
41
A1 A2
– +U
Screw terminal socket
700-HN139
PQ = Package Quantity
8-46 Rockwell Automation
Accessories - Page 8-48Specifications - Page 8-49Dimensions - Page 8-50
Bulletin 700-H
8
Plug-in Style RelaysProduct Selection
Slim Line Relays Type HK with Plug-in Quick Connect Terminations
➊ Pilot light option: Add suffix (-4) to the selected HC relay Cat. No.
Wiring Diagrams(International)
Description Contact Rating Coil VoltageCat. No.
➊PQ
• 1 changeover contact• Contacts:
bifurcated gold overlay, AgCdO
10 A
24 VAC 700-HKX6A24
1
120 VAC 700-HKX6A1
24 VDC 700-HKX6Z24
• 1 changeover contact• Contacts:
AgCdO10 A
24 VAC 700-HK36A24
120 VAC 700-HK36A1
240 VAC 700-HK36A2
24 VDC 700-HK36Z24
110 VDC 700-HK36Z1
• 2 changeover contacts• Contacts:
bifurcated gold overlay, AgCdO
5 A
24 VAC 700-HKX2A24
1
120 VAC 700-HKX2A1
24 VDC 700-HKX2Z24
• 2 changeover contacts• Contacts:
AgCdO5 A
24 VAC 700-HK32A24
120 VAC 700-HK32A1
240 VAC 700-HK32A2
24 VDC 700-HK32Z24
110 VDC 700-HK32Z1
14
11
12
A2
12
A1
U +_
Screw terminal socket
700-HN121
14 24
11 21
12 2212 22
A1A2
U +U +_
Screw terminal socket
700-HN122
PQ = Package Quantity
Rockwell Automation 8-47
Accessories - Page 8-48Specifications - Page 8-49Dimensions - Page 8-50
Bulletin 700-H
8
Plug-in Style RelaysAccessories
Description For Use with Relay Cat. No. PQ
Screw Terminal Socket14 poles Snap-on mounting on DIN rail or with 2 fixing screws
700-HC 700-HN103 1
Screw Terminal Socket8 poles, open typeSnap-on mounting on DIN rail or with 2 fixing screws
700-HF2 changeover
contacts700-HN116 10
Screw Terminal Socket14 poles Snap-on mounting on DIN rail or with 2 fixing screws
700-HF4 changeover
contacts700-HN139 1
Screw Terminal Socket5 poles, with integrated retaining clipSnap-on mounting on DIN rail or with 2 fixing screws
700-HK1 changeover
contacts700-HN121 10
Screw Terminal Socket8 poles, with integrated retaining clipSnap-on mounting on DIN rail or with 2 fixing screws
700-HK2 changeover
contacts700-HN122 10
DescriptionFor Use with
Screw Terminal Socket
Cat. No. PQ
Retaining ClipLocks relay in socket
700-HN103700-HN116700-HN117
700-HN114 10
700-HN139 700-HN140 10
PQ = Package Quantity
8-48 Rockwell Automation
Product Selection - Page 8-46
Bulletin 700-H
8
Plug-in Style RelaysSpecifications
Plug-in Relay
General Data 700-HC… 700-HF… 700-HK…
Test VoltageCoil / contact [kV]Contact / contact [kV]open contact [kV]
1.51.51.5
1.51.51.5
1.51.5—
Ambient temperature
Storage [oC]
Operation [oC]
-30…+85-30…+55
-30…+85-30…+55
-55…+85-30…+55
Rated Insulation Voltage Ui [V] 250 (IEC), 300 (UL/CSA)
Operating LimitsAC 50 Hz [Us]AC 60 Hz [Us]DC [Us]
0.8…1.10.85…1.10.8…1.1
0.8…1.10.85…1.10.8…1.1
0.8…1.10.85…1.10.8…1.1
Power Consumption AC/DCPick-up capacity [VA/W]Holding capacity [VA/W]
50 Hz2.41.6
DC0.90.9
50 Hz2.41.6
DC0.90.9
——
Contact Data
Contact Material700-HC5… 700-HC2… 700-HF3… 700-HK32… 700-HK36…
Ag+Au AgCdO AgCdO AgCdOContact Stress Contact Rating [A]
50 Hz1
DC5 10 10 5
Lifespanmechanical [Mio. operations] 50 30 5Max. No. of Operations (mechanical) 1800/h 3600/h 1800/hStandards and ApprovalsApprovals CE, UL Listed, CSA
Rockwell Automation 8-49
Product Selection - Page 8-46
Bulletin 700-H
8
Plug-in Style RelaysDimensions
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
28.2(1-7/64)
33.5(1-21/64)
41.6
36.1
(1-27/64)
(1-41/64)
24(1-7/64)
13(1/2)
29(1-9/64)
36.1(1-27/64)
33.5(1-21/64)
28.2(1-7/64)
21.8(55/64)
Relay Type HC
Relay Type HF(2 changeover
contacts)
Relay Type HK,(1 and 2 changeover
contacts)
Relay Type HF(4 changeover
contacts)
28.2(1-7/64)
33.5(1-21/64)
21.8
(55/64)36.1
(1-27/64)
8-50 Rockwell Automation
Product Selection - Page 8-46
Bulletin 700-H
8
Plug-in Style RelaysDimensions
Dimensions are shown in millimeters (inches).
25.1(63/64)
48(1-57/64)
4.3(11/64)
(1-1/64)25.9
65.5(2-37/64)
30(1-3/16)
7.9(5/16)
4.0(5/32)
4 3
8 7
6 5
2 1
78.5
45.530
(3-3/32)
(1-25/32)(1-3/16)
68(2-11/16)
36(1-3/16)
7.6(5/16)
35.5(1-13/32)
Cat. No. 700-HN116Cat. No. 700-HN139
M3
67(2-5/8)
30(1-11/64)
24.5(31/32)
44 34 24 14
8 7 6 5
42 32 22 12
4 3 2 1
A2 A1
41 31 21 11
12 11 10 9
28.9(1-9/64)
Panel mounting
Cat. No. 700-HN103
Dimensions are not intended to be used for manufacturing purposes.
Wire size: 2 x 1.5 mm2 (2 - 16 AWG to 1 - 20 AWG)(either solid or stranded)
Strip length: 9 mm - Torque 0.8 Nm
Wire size: 2 x 2.5 mm2 single wire up to 12 AWGTwin wire 2 x 2.5 mm2 (2 - 14 AWG to 2 - 20 AWG)(either solid or stranded)
Strip length: 9 mm - Torque 0.8 Nm
Wire size: 2 x 2.5 mm2 single wire up to 12 AWGTwin wire 2 x 2.5 mm2 (2 - 14 AWG to 2 - 20 AWG)(either solid or stranded)
Strip length: 9 mm - Torque 0.8 Nm
Rockwell Automation 8-51
Product Selection - Page 8-46
Bulletin 700-H
8
Plug-in Style RelaysDimensions
Dimensions are shown in millimeters (inches).
Fünf M3.5 x 0.315
15.6(5/8)
4.06(5/32)
71.6(2-53/64)
7.11(9/32)
114
143
122
1 (–)
(A2)
5 (+)(A1)
(5/64)2.03
4.06(5/32)
35.5(1-13/32)
54.1(2-1/8)
29.9(1-3/16)
19.5(49/64)
❶
❶
ø 3.0(M3)
Cat. No. 700-HN121
Acht M3.5 x 0.315
15.6(5/8)
4.06(5/32)
71.6(2-53/64)
7.11(9/32)
216
245
122
1 (–)
(A2)
8 (+)(A1)
144
227
113
(5/64)2.03
4.06(5/32)
35.5(1-13/32)
54.1(2-1/8)
29.9(1-3/16)
19.5(49/64)
❶ ø 3.0(M3)
❶
Cat. No. 700-HN122
Wire size: 2 x 2.5 mm2 Single wire up to 12 AWGTwin wire: 2 x 2.5 mm2 (2 - 14 AWG to 2 - 20 AWG)(either solid or stranded)
Strip length: 9 mm - Torque 0.8 Nm
➊ Mounting hole Ø 3mm
Wire size: 2 x 2.5 mm2 Single wire up to 12 AWGTwin wire: 2 x 2.5 mm2 (2 - 14 AWG to 2 - 20 AWG)(either solid or stranded)
Strip length: 9 mm - Torque 0.8 Nm
8-52 Rockwell Automation
Product Selection - Page 8-46
Bulletin 700-M, 700-CF
8
Miniature Control Relays
Table of ContentsDescription Page Description PageOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Product Selection
Miniature Control Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-54
Special Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-56
Control Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-57
Accessories
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-59
Mounting Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-63
Labeling Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-63
Spare Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-63
Specifications
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-64
Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-66
Standards and Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-66
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-67
Bulletin 700-M / MB Miniature Control Relays• Up to 8 N.O. or up to 4 N.C.• Switching Capacity AC-1 / 12 A
Bulletin 700-CF Miniature Control Relays• High Contact Safety• Solid-State and Pneumatic Timing Modules• Low Pollution Material• Space Saving Coil Components• Same Accessories as
Bulletin 100-C Contactors
Bulletin 700S-CF Control Relays• Comprehensive Safety for Personnel and
Machinery • Protection against Unintended Operation• Electronic Compatible Auxiliary Contacts
Rockwell Automation 8-53
Bulletin 700-M, 700-CF
8
Miniature Control RelaysProduct Selection
AC Control
DC Control
AC-1 AC-15Connection Diagrams
Cat. No. PQIe [A] Ie [A]
40°C 24/48 V 120 V 230 V 240 V 400 V 500 V 600 V 690 V
16 — — 6 — 2.5 1.25 — —
700-M220⊗
700-M310⊗
700-M400⊗
700-MZ220⊗
25 16 14 — 10 5 2.5 1.8 1
700-CF220⊗
700-CF310⊗
700-CF400⊗
AC-1 AC-15Connection Diagrams
Cat. No PQIe [A] Ie [A]
40°C 24/48 V 120 V 230 V 240 V 400 V 500 V 600 V 690 V
16 — — 6 — 2.5 1.25 — —
700DC-M220⊗
700DC-M310⊗
700DC-M400⊗
700DC-MZ220⊗
25 16 14 — 10 5 2.5 1.8 1
700-CF220⊗
700-CF310⊗
700-CF400⊗
700-CF310⊗ 700-CF400⊗700-CF220⊗700-M
Miniature Control Relays
• AC / DC Control
14
13
22
21A1
A2 32
31
44
43
14
13A1
A2 22
21
34
33
44
43
44
43
14
13
24
23
34
33A1
A2
14
13
22
21A1
A2 48
47
36
35
14
13
32
31A1
A2 22
21
44
43
14
13
34
33A1
A2 22
21
44
43
44
43
14
13
24
23
34
33A1
A2
14
13
22
21A1
A2 32
31
44
43
14
13A1
A2 22
21
34
33
44
43
44
43
14
13
24
23
34
33A1
A2
14
13
22
21A1
A2 48
47
36
35
14
13
32
31A1
A2 22
21
44
43
14
13
34
33A1
A2 22
21
44
43
44
43
14
13
24
23
34
33A1
A2
PQ = Package Quantity
8-54 Rockwell Automation
Accessories - Page 8-59Specifications - Page 8-64Dimensions - Page 8-67
Bulletin 700-M, 700-CF
8
Miniature Control RelaysProduct Selection
⊗ Voltage Suffix Codes for AC Control
⊗ Voltage Suffix Codes for DC Control
( ) Control voltages in parentheses: No inventory (longer delivery time)
➊ Extended operating limits 0.65…1.3 x Us
➋ Extended operating limits 0.7…1.25 x Us
700-M
[V] 24 48 110110-120
220-230
230230-240
240380-400
400-415
50 Hz — — A1 — (A2) — — — A360 Hz — — — A1 — — (A2) — — A350/60 Hz A24 A48 — — — KF — (A23) — —
700-CF
[V] 12 24 32 36 42 48 100100-110
110 120 127 200200-220
200-230
208-240
50 Hz (R) (K) (V) (W) (X) (Y) (KP) — (D) (P) (S) (KG) — — —60 Hz (Q) (J) — (V) — (X) — (KP) — (D) — — (KG) — (L)50/60 Hz — KJ — — — KY (KP) — KD — — (KG) — (KL) —
[V]220-230
230230-240
240 277 347 380380-400
400400-415
440 480 500 550 600
50 Hz (F) — (VA) (T) — — — (N) — (G) (B) — (M) (C) —60 Hz — — — (A) (T) (I) (E) — — — (N) (B) — — (C)50/60 Hz — KF — (KA) — — — — KN — (KB) — — — —
700DC-M..Z[V] 24 48 110 220
DC Z24 (Z48) Z11 (Z2)
with diode protection circuit DC D24 — —
700-CF[V] 9 ➊ 12 24 ➋ 36 48 60 64 72 80 110 115 125 220 230 250
DC (ZR) (ZQ) ZJ (ZW) (ZY) (ZZ) (ZB) (ZG) (ZE) ZD (ZP) (ZS) (ZA) (ZF) (ZT)
with diode protection circuit DC — — DJ — — — — — — — — — — — —
Price Adder for: Type Available Control Voltages No Surcharge
Special control voltages700-M, 700DC-M 12…500 V50Hz / 12…600 V60Hz / 12…250 VDC > 25 pieces700-CF 12…600 V50Hz / 12…600 V60Hz / 12…250 VDC > 20 pieces
Options Cat. No. Suffix Description Ordering Example
⊗ Control Voltage e.g. A1 Insert standard control voltage code from table above 700-M220A1
Package quantity 700-MBlank Multi-pack (10 pieces) (A24, A1, KF, A3 only) 700-M220⊗
S Single pack (1 piece, standard) 700-M220⊗S
Package quantity 700-CBlank Single pack (1 piece, standard) 700-CF220⊗
M Multi-pack (20 pieces) 700-CF220⊗M
!Attention:Bulletin 700-M…S: standard quantity = single item (1 piece)Bulletin 700-C: standard quantity = single item (1 piece)
Rockwell Automation 8-55
Accessories - Page 8-59Specifications - Page 8-64Dimensions - Page 8-67
Bulletin 700-M, 700-CF
8
Miniature Control RelaysProduct Selection
Latched Auxiliary Contact 700-ML
Coupling Contact 700-MB (with Bifurcated Contacts)
AC-1 AC-15
Connection Diagrams PQIe [A] Ie [A] Cat. No.
40°C 24/48 V 120 V 230 V 240 V 400 V 500 V
16 — — 6 — 2.5 1.25
700-ML220 ⊗
1700-ML310 ⊗
700-ML400 ⊗
AC-1 AC-15Connection Diagrams PQIe [A] Ie [A] Cat. No.
40°C 24/48 V 120 V 230 V 240 V 400 V 500 V
16 — — 6 — 2.5 1.25
700-MB220 ⊗
1
700-MB310 ⊗
700-MB400 ⊗
10 — — 6 — 2.5 1.25
700DC-MB220 ⊗
700DC-MB310 ⊗
700DC-MB400 ⊗
Special Versions
• Latched Auxiliary Contact 700-ML (AC only)• Coupling Contact 700-MB
(Bifurcated Contacts)• AC / DC Control
700-MB700-ML
84
83
62
61 E1
E274
73
54
53
22
21
32
31 A1
A224
23
14
13
84
83
62
61 E1
E274
73
54
53
44
43
22
21 A1
A234
33
14
13
84
83
62
61 E1
E274
73
54
53
34
33
44
43 A1
A224
23
14
13
14
13
32
31A1
A2 22
21
44
43
14
13
34
33A1
A2 22
21
44
43
44
43
14
13
24
23
34
33A1
A2
14
13
32
31A1
A2 22
21
44
43
14
13
34
33A1
A2 22
21
44
43
44
43
14
13
24
23
34
33A1
A2
PQ = Package Quantity
8-56 Rockwell Automation
Accessories - Page 8-59Specifications - Page 8-64Dimensions - Page 8-67
Bulletin 700-M, 700-CF
8
Miniature Control RelaysProduct Selection
⊗ Voltage Suffix Codes for AC Control
⊗ Voltage Suffix Codes for DC Control
( ) Control voltages in parentheses: No inventory (longer delivery time)
➊ Extended operating limits 0.65…1.3 x Us
➋ Extended operating limits 0.7…1.25 x Us
AC-1 AC-15
Connection Diagrams PQIe [A] Ie [A] Cat. No.
40°C 24/48 V 120 V 230 V 240 V 400 V 500 V 600 V 690 V
16 — — 6 — 2.5 1.25 1.8 1
700S-CF620⊗C
1700S-CF530⊗C
700S-CF440⊗C
700-ML, 700-MB
[V] 24 48 110110-120
220-230
230230-240
240380-400
400-415
50 Hz — — A1 — (A2) — — — A360 Hz — — — A1 — — (A2) — — A350/60 Hz A24 A48 — — — KF — (A23) — —
700S-CF
[V] 12 24 32 36 42 48 100100-110
110 120 127 200200-220
200-230
208-240
50 Hz (R) (K) (V) (W) (X) (Y) (KP) — (D) (P) (S) (KG) — — —60 Hz (Q) (J) — (V) — (X) — (KP) — (D) — — (KG) — (L)50/60 Hz — KJ — — — KY (KP) — KD — — (KG) — (KL) —
[V]220-230
230230-240
240 277 347 380380-400
400400-415
440 480 500 550 600
50 Hz (F) — (VA) (T) — — — (N) — (G) (B) — (M) (C) —60 Hz — — — (A) (T) (I) (E) — — — (N) (B) — — (C)50/60 Hz — KF — (KA) — — — — KN — (KB) — — — —
700DC-MB[V] 24 48 110 220
DC Z24 (Z48) Z11 (Z2)
with diode protection circuit DC D24 — —
700S-CF[V] 9 ➊ 12 24 ➋ 36 48 60 64 72 80 110 115 125 220 230 250
DC (ZR) (ZQ) ZJ (ZW) (ZY) (ZZ) (ZB) (ZG) (ZE) ZD (ZP) (ZS) (ZA) (ZF) (ZT)
with diode protection circuit DC — — DJ — — — — — — — — — — — —
Price Adder for: Type Available Control Voltages No Surcharge
Special control voltages700-ML, 700-MB 12…500 V50Hz / 12…600 V60Hz > 25 pieces700DC-MB 12…250 VDC > 25 pieces700S-CF 12…600 V50Hz / 12…600 V60Hz / 12…250 VDC > 20 pieces
Control Relays
• AC / DC Control• Positively guided contacts according to IEC 947-5-1• Fixed coupling of contactor and auxiliary contact block• Protection against unintended actuation• Auxiliary contacts are electronic compatible acc.
to DIN 19240
14
13
34
33A1
A2 22
21
44
43
84
83
54
53
62
61
74
73
14
13
34
33A1
A2 22
21
44
43
84
83
54
53
62
61
72
71
14
13
34
33A1
A2 22
21
44
43
54
53
62
61
72
71
82
81
PQ = Package Quantity
Rockwell Automation 8-57
Accessories - Page 8-59Specifications - Page 8-64Dimensions - Page 8-67
Bulletin 700-M, 700-CF
8
Miniature Control RelaysProduct Selection
Device Combinations in Accordance with EN Index
➊ Miniature control relay and auxiliary contact block AC / DC max. 4 N.C.
Auxiliary Contact Block Miniature Control Relays 700-M(B) AC / DC Control
Connection Diagrams
Control 700-M⊗220 700-M⊗310700-M⊗400
700-MB⊗400700-M⊗Z220 700-MB⊗220 700-MB⊗310
Front-mounted
195-MA02 AC / DC — — 40E + 02 = 42E — — —
195-MA11 AC / DC — — 40E + 11 = 51E — — —
195-MA20 AC / DC — — 40E + 20 = 60E — — —
195-MA04 AC / DC — — 40E + 04 = 44E — — —
195-MA22 AC / DC — — 40E + 22 = 62E — — —
195-MA40 AC / DC 22Z + 40 = 62Z 31Z + 40 = 71Z 40E + 40 = 80E 22Z + 40 = 62Z 22E + 40 = 62E 31E + 40 = 71E
Auxiliary Contact Block Miniature Control Relays 700-CF AC / DC Control
Connection Diagrams
Control 700-CF⊗220 700-CF⊗310 700-CF⊗400
Front-mounted ➊
100-FA02 AC / DC 22E + 02 = 24E 31E + 02 = 33E 40E + 02 = 42E
100-FA11 AC / DC 22E + 11 = 33E 31E + 11 = 42E 40E + 11 = 51E
100-FA20 AC / DC 22E + 20 = 42E 31E + 20 = 51E 40E + 20 = 60E
100-FA22 AC / DC 22E + 22 = 44E 31E + 22 = 53E 40E + 22 = 62E
100-FA31 AC / DC 22E + 31 = 53E 31E + 31 = 62E 40E + 31 = 71E
100-FA40 AC / DC 22E + 40 = 62E 31E + 40 = 71E 40E + 40 = 80E
100-FAL22 AC / DC 22E + 22 = 44E 31E + 22 = 53E 40E + 22 = 62E
14
13
22
21A1
A2 32
31
44
43
14
13A1
A2 22
21
34
33
44
43
44
43
14
13
24
23
34
33A1
A2 14
13
22
21A1
A2 48
47
36
35
14
13
32
31A1
A2 22
21
44
43
14
13
34
33A1
A2 22
21
44
43
52
51
62
61
54
53
62
61
6454
6353
82
81
52
51
62
61
72
71
72
71
54
53
84
83
62
61
84
83
54
53
64
63
74
73
14
13
32
31A1
A2 22
21
44
43
14
13
34
33A1
A2 22
21
44
43
44
43
14
13
24
23
34
33A1
A2
52
51
62
61
54
53
62
61
6454
6353
84
83
54
53
62
61
72
71
84
83
54
53
62
61
74
73
84
83
54
53
64
63
74
73
88
87
54
53
62
61
76
75
8-58 Rockwell Automation
Product Selection - Page 8-54
Bulletin 700-M, 700-CF
8
Miniature Control RelaysAccessories
Components: Auxiliary Contact Blocks
➊ Up to 8 auxiliary contacts may be mounted: Auxiliary contact + front mounting (AC max. 4 N.C. / DC max. 4 N.C), side mounting (AC max. 2 N.O. / DC max. 2 N.O. and max. 2 N.C.)
Description Connection Diagrams For Use with Type Cat. No. PQ
Auxiliary Contact Blocks for Front Mounting• 2- and 4-poles• Quick and easy mounting without tools• Electronic compatible bifurcated contacts• Contacts in auxiliary contact block positively
guided• Models with equal function with several terminal
numbering choices
700-M400 195-MA02
10
700-M400 195-MA11
700-M400, -M310, -M220, -MZ220
195-MA20
700-M400 195-MA04
700-M400 195-MA22
700-M400, -M310, -M220, -MZ220
195-MA40
Auxiliary Contact Blocks for Front Mounting ➊• 2- and 4-poles• Quick and easy mounting without tools• Electronic compatible contacts• Positive guidance in auxiliary and with main
contactor poles (excluding type L)• Models with equal function with several terminal
numbering choices• Auxiliary contacts for side mounting
(Please note double numbering)
L = Early Make/Late Break
700-CF 100-FA02
700-CF 100-FA11
700-CF 100-FA20
700-CF 100-FA22
700-CF 100-FA31
700-CF 100-FA40
700-CF 100-FAL22
Options Cat. No. Suffix Description Ordering Example
Package quantityBlank Single pack (1 piece, standard) 100-FA11
M Multi-pack (10 pieces) 100-FA11M
52
51
62
61
54
53
62
61
6454
6353
82
81
52
51
62
61
72
71
72
71
54
53
84
83
62
61
84
83
54
53
64
63
74
73
52
51
62
61
54
53
62
61
6454
6353
84
83
54
53
62
61
72
71
84
83
54
53
62
61
74
73
84
83
54
53
64
63
74
73
88
87
54
53
62
61
76
75
PQ = Package Quantity
Rockwell Automation 8-59
Product Selection - Page 8-54
Bulletin 700-M, 700-CF
8
Miniature Control RelaysAccessories
Components: Timers
DescriptionConnection Diagrams
For Use with Type
Cat. No. PQ
Pneumatic TimerPneumatic timing contacts switch after the set time; the contacts on the main contactor oper-ate without delay.• Continuous adjustment range
On-delay0.3 … 30 s
1.8 … 180 s
700-CFwith
AC coil100-FPTA30
100-FPTA1801
Off-delay0.3 … 30 s
1.8 … 180 s
700-CFwith
AC coil100-FPTB30
100-FPTB180
TimersAfter the set time has elapsed, the timer oper-ates and the contactor in series is energised.
On-delay1 … 3 s
1 … 30 s
700-M with
110 … 250 V 50/60 Hz / DC
196-MT3S196-MT30S
10
Timers for Y-∆ Switching After the set time has elapsed, the K3 contac-tor (Y) is de-energised and then after a time of 90 ± 30 ms the K2 contactor (∆) is energised.
Switch-on time
Y-contactor1 … 30 s
700-M with110 … 120 V
50/60 Hz196-MTSDA1
10
1 … 30 s700-M with
220 … 250 V50/60 Hz
196-MTSDA2
Electronic Timing ModulesDelay of contactor trip coil• Continuous adjustment range• High repeat accuracy100-ETAThe contact closes after the delay time elapses.
On-delay0.1 … 3 s1 … 30 s
10 … 180 s
700-CFwith
110…240 V 50/60 Hz110…250
VDC
100-ETA3100-ETA30
100-ETA1801
0.1 … 3 s1 … 30 s
10 … 180 s
700-CFwith
24…48 VDC
100-ETAZJ3100-ETAZJ30
100-ETAZJ180
100-ETBAfter interruption of the control signal, the contactor is switched off after the delay time elapses.
Off-delay0.3 … 3 s1 … 30 s
10 … 180 s
700-CFwith 24 V
50/60 Hz
100-ETBKJ3100-ETBKJ30
100-ETBKJ180
1700-CF
with110 … 240 V
50/60 Hz
100-ETB3100-ETB30
100-ETB180
100-ETYAfter the set Y time has elapsed the K3 contact (Y) is switched off and the K2 (∆) is switched on.(Switching delay ∆t 50 ms)
Switch-on time
Y-contactor1 … 30 s
700-CFwith
110 … 240 V50/60 Hz
100-ETY30 1
68
67
56
55
66
65
58
57
S1
NK1
1
2
O / I
~
S1
NK1
1
K2 K3∆ Y
K3 K2Y ∆
K2∆
∆Y2
O / I
~
L
A1 (K1M)
L
S
N
A1K1M
A2
A1
tA1
L
N
A2
A1
L
B2A1
S
K1M
tB2
A1 (K1M)
L
D A1
Y A1
L
S
N
A1H Y
Y
D
D
A2
D1 Y1
A1
A2
A1
A2
t
H A1 ∆t
PQ = Package Quantity
8-60 Rockwell Automation
Product Selection - Page 8-54
Bulletin 700-M, 700-CF
8
Miniature Control RelaysAccessories
Components: Mechanical Latch
⊗ Voltage Suffix Codes for AC Control
( ) Control voltages in parentheses: No inventory (longer delivery time)
DescriptionConnection Diagrams
For Use withType
Cat. No. PQ
Mechanical Interlockfor Bulletin 700-M Contactors• For interlocking of two adjacent contactors• Without additional space requirement attachable
from rear and recessed in top hat rail
700-M withAC coil
199-MXM1 10
Mechanical Interlockfor Bulletin 700-CF ContactorsFor interlocking of two adjacent auxiliary contactors/relays.• Mechanical and electrical interlock in one module
possible by means of integrated auxiliary contacts• 9 mm connecting piece included
• withoutauxiliarycontact
700-CF 100-MCA00
• with 2 N.C.auxiliarycontacts
700-CF 100-MCA02
Mechanical LatchIn latching contactors, the contactor coil is immediately switched off after the contact on the latch closes (65-66); consequently, no holding current flows. Can be used for both AC and DC operation.• Auxiliary Contacts 1 N.O. + 1 N.C.
700-CF with AC coil
100-FL11⊗ 1
Options Cat. No. Suffix Description Ordering Example
⊗ Control Voltage e.g. KJ Insert standard control voltage code from table below 100-FL11KJ
Package quantityBlank Single pack (1 piece, standard) 100-MCA02
M Multi-pack (10 pieces) 100-MCA02M
100-FL11
[V] 12 24 32 36 42 48 100100-110
110 120 127 200200-220
200-230
208-240
50 Hz (R) (K) (V) (W) (X) (Y) (KP) — (D) (P) (S) (KG) — — —60 Hz (Q) (J) — (V) — (X) — (KP) — (D) — — (KG) — (L)50/60 Hz — KJ — — — KY (KP) — KD — — (KG) — (KL) —
[V]220-230
230230-240
240 277 347 380380-400
400400-415
440 480 500 550 600
50 Hz (F) — (VA) (T) — — — (N) — (G) (B) — (M) (C) —60 Hz — — — (A) (T) (I) (E) — — — (N) (B) — — (C)50/60 Hz — KF — (KA) — — — — KN — (KB) — — — —
Price Adder For: Type Available Control Voltages No Surcharge
Special control voltages 100-FL11 12…500 V 50 Hz / 12…600 V 60 Hz > 25 pieces
22
21
22
21
E1
E2
A1
A2
14
13
K1R
L1~/L+
N~/L-
K1M
58
57
66
65
K1R
0
I
K1M
PQ = Package Quantity
Rockwell Automation 8-61
Product Selection - Page 8-54
Bulletin 700-M, 700-CF
8
Miniature Control RelaysAccessories
Components
DescriptionConnection Diagrams
For Use with Type
Cat. No. PQ
Interface (electronic)Interface between the DC control signal (PLC) and the AC operating mechanism of the contactor or relay.• Control voltage
18 … 30 VDC (10…15 mA)• For coil voltages of
110…240 VAC• Suitable for all 700-CF
contactors with AC control • Switching capacity 200 VA• Requires no overvoltage pro-
tection for the coils
Input Output
24 VDC
12 VDC
48 VDC
110 …240 VAC
700-CF, 700S-CF
with AC coil
100-JE
100JE12
100JE48
Surge Suppressors for 700-MFor limiting surge voltage for coils
RC ModuleAC operating mechanism24…48 VAC110…240 VAC
2-wire ver-sion 199-MSMA48
199-MSMA1 1024…48 VAC110…280 VAC380…480 VAC
700-M199-MSMNA48
199-MSMNA280199-MSMNA480
Diode ModuleDC operating mechanism12…250 VDC
2-wire vers. 199-MSMD1
10700-M 199-MSMD2
Varistor ModuleAC/DC- operating mechanism12…55 VAC / 12…77 VDC56…136 VAC / 78…178 VDC137…277 VAC / 181…350 VDC
700-M 199-MSMV4199-MSMV5199-MSMV6
10
Surge Suppressors for 700-CFFor limiting switching overvoltage of the solenoids.• Can be plugged into coil ter-
minals of all 700-CF contac-tors
RC ModuleRC 24…48 VACRC 110…280 VACRC 380…480 VAC
2-wire ver-sion
100-FSC48W100-FSC280W100-FSC480W
24…48 V 50/60 Hz110…280 V 50/60 Hz380…480 V 50/60 Hz
700-C, 700S-CF
withAC coil
100-FSC48100-FSC280100-FSC480
Diode Module12…250 VDC
2-wire version
100-FSD250W
700-CF,700S-CF
with DC coil100-FSD250
Varistor Module12…55 VAC / 12 … 77 VDC56…136 VAC / 78 … 180 VDC137…277 VAC / 181 …350 VDC278… 575 VAC
2-wire ver-sion
100-FSV55W100-FSV136W100-FSV277W100-FSV575W
12…55 VAC / 12 … 77 VDC56…136 VAC / 78 … 180 VDC137…277 VAC / 181 …350 VDC278… 575 VAC
700-CF,700S-CF
with AC/DC coil
100-FSV55100-FSV136100-FSV277100-FSV575
Contact Safety Circuit24 … 250 VDC
700-C 100-FSC250W
Options Cat. No. Suffix Description Ordering Example
Package quantityBlank Single pack (1 piece, standard) 100-FSC48
M Multi-pack (10 pieces) 100-FSC48M
L
N
A2
A1
L
E1A1 E2
K1M
E1
A1 (K1M)
8-62 Rockwell Automation
Product Selection - Page 8-54
Bulletin 700-M, 700-CF
8
Miniature Control RelaysAccessories
Mounting Material
Labeling Material
Spare Parts: Coils
➊ Extended operating limits 0.65…1.3 x Us
➋ Extended operating limits 0.7…1.25 x Us
Description Cat. No. PQ
Adapter 196-MTM / CR 4-P• For easy, toolless mounting of timers on to DIN Rails EN 50 022-35 and G Rails
196-MTM 10
Protective Cover• Provides protection against unintended manual operation• For miniature control relays and auxiliary contacts in safety
circuits
For 700-CFFor 100-FA, 100-FP, 100-FL
100-SCC100-SCF
• Uniform labelling materials for contactors, motor protection devices, timing relays, and circuit breakers.Product information and ordering statements see chapter 3.
Standard Control Voltages 700-CF
AC Voltage DC Voltage
50 Hz 60 Hz 50 / 60 HzACCoil
Code
PQ = 1050 Hz 60 Hz
50 /60 Hz
ACCoil
Code
PQ = 10VDC
DCCoil-Code
PQ = 10
Cat. No. Cat. No. Cat. No.
12 V Q TA006 208…240 V L TA296 9 V ➊ ZR TA76612 V R TA404 220 V 240 V A TA474 12 V ZQ TA708
24 V J TA013 220…230 V F TA441 24 V Diode ➋ DJ TA714M24 V K TA407 230 V KF TA851 24 V ZJ TA714
24 V KJ TA855 230…240 V VA TA440 36 V ZV TA71932 V 36 V V TA481 240 V 277 V T TA480 48 V ZJ TA72436 V W TA410 240 V KA TA858 60 V ZZ TA77442 V 48 V X TA482 347 V I TA065 64 V ZB TA72748 V Y TA414 380 V E TA067 72 V ZG TA728
48 V KY TA860 380…400 V 440 V N TA071 80 V ZE TA729100 V 100…110 V KP TA861 400 V KN TA863 110 V ZD TA733110 V 120 V D TA473 400…415 V G TA457 115 V ZP TA734
110 V KD TA856 440 V 480 V B TA475 125 V ZS TA737120 V P TA425 440 V KB TA859 220 V ZA TA747127 V S TA428 500 V M TA479 230 V ZF TA749200 V 200…220 V KG TA862 550 V 600 V C TA476 250 V ZT TA751
200…230 V KL TA864
Price Adder for: Type Available Control Voltages No Surcharge
Special control voltages 700-CF Special control voltages on request 12…500 V 50 Hz / 12…600 V 60 Hz > 20 pieces
PQ = Package Quantity
Rockwell Automation 8-63
Product Selection - Page 8-54
Bulletin 700-M, 700-CF
8
Miniature Control RelaysSpecifications
IEC SpecificationsContactors, Auxiliary Contact Blocks and Accessories
Miniature Control Relays Aux. Contact Blocks Mini. Control Relays Aux. Contact Blocks
700-M 700-MB and Accessories 700-CF, 700S-CF and AccessoriesAC-1 Active Power Load, Switching of 3-phase MotorsAmbient temperature 40 °CIe 24…240 V [A] — 10 10 — —
230…500 V [A] 16 — — — —230…690 V [A] — — — 25 10
24 V [kW] — 0.41 0.41 — —48 V [kW] — 0.83 0.83 — —
110 V [kW] — 1.9 1.9 — —230 V [kW] 6.4 4 4 10 —400 V [kW] 11 — — 17 —500 V [kW] 14 — — — —690 V [kW] — — — 30 —
Ambient temperature 60 °CIe 24…240 V [A] — 6 6 — —
230…500 V [A] 12 — — — —230…690 V [A] — — — 20 6
24 V [kW] — 0.25 0.25 — —48 V [kW] — 0.5 0.5 — —
110 V [kW] — 1.1 1.1 — —230 V [kW] 4.8 2.4 2.4 8 —400 V [kW] 8.3 — — 14 —500 V [kW] 10.4 — — — —690 V [kW] — — — 24 —
Switching of 3-phase MotorsAC-2, AC-3, AC-4 230 V [A] 5 — — 11.5 —
400 V [A] 3.7 — — 9 —500 V [A] 2.8 — — — —690 V [A] — — — 5 —230 V [kW] 1.3 — — 3 —400 V [kW] 1.7 — — 4 —500 V [kW] 1.6 — — — —690 V [kW] — — — 4 —
Switching of SolenoidsAC-15 24 V [A] — — — 16 6
48 V [A] — — — 16 6120 V [A] — — — 14 6230 V [A] 6 2.5 2.5 — —240 V [A] — — — 10 3400 V [A] 2.5 2 2 5 2500 V [A] 1.25 2 2 2.5 1.5600 V [A] — — — 1.8 1.2690 V [A] — — — 1 0.7
Short-circuit ProtectionCoordination Type 2 acc. to IEC 947-4-1(IEC 158-1) Fuse gG [A] 16 — 16 10 10Min. Switching Capacity 17 VDIN 19240 for bifurcated contacts (control relays with bifurcated contactsand auxiliary contact blocks [mA]
5 5 5 5 5
Switching of DC currentNon-inductive or slightly inductive loads, resistance furnaces DC-1 at 60 °C1 pole 24/48 V [A] 6/4 — — 25/20 —
110 V [A] 0.6 — — 6 —220 V [A] 0.2 — — 1.5 —440 V [A] 0.08 — — 0.4 —
2 poles in serie 24/48 V [A] 6 — — 25 —110 V [A] 4 — — 25 —220 V [A] 0.8 — — 8 —440 V [A] 0.2 — — 1 —
3 poles in serie 24/48 V [A] 6 — — 25 —110 V [A] 6 — — 25 —220 V [A] 3 — — 25 —440 V [A] 0.4 — — 3 —
8-64 Rockwell Automation
Product Selection - Page 8-54
Bulletin 700-M, 700-CF
8
Miniature Control RelaysSpecifications
IEC Specifications
Contactors, Auxiliary Contact Blocks and Accessories
* Pozidriv No. 2 / slot No. 3
Coil Circuits
Miniature Control Relays Aux. Contact Blocks Mini. Control Relays Aux. Contact Blocks
700-M 700-MB and Accessories 700-CF, 700S-CF and Accessories
Load Carrying Capacity acc. to UL/CSA Lloyd’s Register of ShippingOperating Voltage AC [V] 115 — — — —
AC [V] 200 — — — —AC [V] 230 — — — —AC [V] 460 — — — —AC [V] 575 — — — —
Continuous Current(General Purpose) 300 V [A] 10 10 10 25 10
600 V [A] 10 — 10 25 10Lifespan mechanical [Mio. operations] 10 10 15 15AC-15 (240 V / 3 A) [Mio. operations] — — — 1.5 1.5AC-1 (230 V / 6 A) [Mio. operations] 0.7 0.7 — —Terminals * * * * *Terminal type*
1. cond. [mm2]
2. cond. [mm2]
0.75 … 2.5 0.75 … 2.5 0.75 … 2.5 1 … 4 0.5 … 2.5
0.75 … 2.5 0.75 … 2.5 0.75 … 2.5 1 … 4 0.75 … 2.5
1. cond. [mm2]
2. cond. [mm2]
0.75 … 2.5 0.75 … 2.5 0.75 … 2.5 1.5 … 6 0.5 … 2.5
0.75 … 2.5 0.75 … 2.5 0.75 … 2.5 1.5 … 6 0.75 … 2.5
Recommended torque [Nm] 1 … 1.5 1 … 1.5 1 … 1.5 1 … 2.5 1 … 1.5Cross section acc. to UL/CSA [AWG] 18 … 14 18 … 14 18 … 14 16 … 10 18 … 14Recommended torque [lb-in] 7 … 15 7 … 15 7 … 15 8.9 … 22 8.9 … 13.3
Miniature Control Relays Aux. Contact Blocks Mini. Control Relays Aux. Contact Blocks
700-M 700-MB and Accessories 700-CF, 700S-CF and Accessories
Operating LimitsAC control (50 Hz, 60 Hz, 50/60 Hz)
pick-up [x Us] 0.85 … 1.1 — 0.85 … 1.1 —dropout [x Us] 0.35 … 0.65 — 0.3 … 0.6 —
DC control pick-up [x Us] 0.8 … 1.1 — 0.8 … 1.1 —dropout [x Us] 0.1 … 0.25 — 0.1 … 0.6 —
integrated protection circuit opening delaydropout [Umax/Umin] 1 … 1.2 — —
Pick-up and Holding PowerAC control (50 Hz, 60 Hz, 50/60 Hz)
pick-up [VA/W] 22/20 — 70/50 —holding [VA/W] 4/1.4 — 8/2.6 —
DC control pick-up [W] 2.5 — 6 —holding [W] 2.5 — 6 —
Switching DelayAC control closing delay [ms] 15 … 40 — 15 … 30 —
opening delay [ms] 15 … 25 — 10 … 60 —with RC moduleopening delay [ms] 15 … 25 — 10 … 60 —DC control closing delay [ms] 18 … 40 — 40 … 70 —
opening delay [ms] 6 … 12 — 7 … 15 —
with diode moduleopening delay [ms] 35 … 50 — 70 … 95 —
integrated protection circuit opening delay DJ opening delay [ms] 8 … 12 — 14 … 20 —
Rockwell Automation 8-65
Product Selection - Page 8-54
Bulletin 700-M, 700-CF
8
Miniature Control RelaysSpecifications
IEC Specifications
Contactors, Auxiliary Contact Blocks and Accessories
General
Miniature Control Relays Aux. Contact Blocks Mini. Control Relays Aux. Contact Blocks
700-M 700-MB and Accessories 700-CF, 700S-CF and Accessories
Rated Insulation Voltage Ui
IEC [V] 500 600acc. to UL, CSA [V] 600 6901 minute acc. to IEC 947-4 (IEC 158-1)[V] 2 500 2 500
Rated Impulse Voltage Withstand Uimp
Degree of soiling,Shock resistance [kV] 8 8Rated Operating Voltage Ue
AC [V] ≤ 500 — ≤ 690DC [V] ≤ 440 — ≤ 440Rated Coil Frequency AC 50/60 Hz, DC AC 50/60 Hz, DCAmbient temperatureStorage [°C] -55 … +80 (-67 …+176 °F) -55 …+80 (-67 …+176 °F)Operation at rated current [°C] -50 … +60 (-67 …+140 °F) -25 …+60 (-13 …+140 °F)at>70 °C 15% current reduction against 60 °C values 15% current reduction against 60 °C valuesClimatic Withstand IEC 68-2 IEC 68-2Altitude of Installation [m] 2000 NN, according to IEC 947-4 2000 NN, according to IEC 947-4Protection Class IP20 IP20
Protection Against Accidental ContactFinger and back-of-hand proof
according to VDE 0106, Part 100Finger and back-of-hand proof
according to VDE 0106, Part 100Weights AC Control [g] 153 — 390 —DC Control [g] 153 — 600 —Standards
IEC 60947; EN 60947; UL 508; CSA 22.2. No. 14
IEC 60947; EN 60947; UL 508; CSA 22.2. No. 14
Approvals CE, UL Listed, CSA, Germanischer Lloyd, Bureau Veritas, Lloyd’s Register of Shipping, Maritime Register of Shipping
CE, UL Listed, CSA
8-66 Rockwell Automation
Product Selection - Page 8-54
Bulletin 700-M, 700-CF
8
Miniature Control RelaysDimensions
Bulletin 700-M
➊ May be mounted to 35 mm EN 50 022DIN rail.(Combined DIN / C rail not applicable with mechanical latch or mechanical interlock)
Bulletin 700-CF
➊ May be mounted to 35 mm EN 50 022DIN rail
Type a a1 b b1 c c1 c2 ød d1 d2
700-M 45 67 56 47 48 74 77 4 50 40 ➊
Type a b c c1 c2 c3 ød d1 d2
700-CF 45 81 80.5 75.5 6 4.5 2 St. à 4.5 60 35 ➊
c2
c1
c
a
a1
d2
ød
b1d1b
➊
23˚ 23˚ 90˚
90˚
Dimensions are shown in millimeters Mounting Position
Miniature Control Relay with [mm]
Mechanical latch a+aAuxiliary contact clock c1Timer on miniature control relay c2
lateral on miniature control relay a1
Miniature Control Relay with [mm]
Neutral terminal lateral on miniature control relay a+20Suppressor module c2Legend plate carrier c..+5
cc1
+...
ø d
b
d1
d2a +...+...
+...
c2
c3
115˚115˚
25˚ 25˚
Dimensions are shown in millimeters
AC-Control
DC Control
115˚115˚ 11
5˚
25˚Mounting Position
Miniature Control Relay with [mm]
Auxiliary contact block for front-mounting 2-, or 4-poles c/c1 + 39Auxiliary contact block for side-mounting 1-, or 2-poles a + 9Pneumatic timing module c/c1 + 58Solid-State timing module on coil connection side b + 24Mechanical interlock lateral on contactor a + 9Mechanical latch c/c1 + 61
Miniature Control Relay with [mm]
Interface on coil connection side b + 9Suppressor module on coil connection side b + 3➋ Marking with Labeling sheet
Labeling sheet with coverLegend plate for V4 / V5 systemLegend plate for Bul. 1492W system
+ 0+ 0
+ 5.5+ 5.5
Rockwell Automation 8-67
Product Selection - Page 8-54
Bulletin 700-M, 700-CF
8
Miniature Control RelaysDimensions
Bulletin 700S-CF
Accessories
➊ May be mounted to 35 mm EN 50 022DIN rail
Type a b c c1 c2 c3 ød d1 d2
700S-CF 45 81 119.5 114.5 6 4.5 2 St. à 4.5 60 35 ➊
Contactors with…AC Control DC Control
[mm] [inches] [mm] [inches]
Auxiliary contact clock for side mounting 1-, or 2-poles a + 9 a + 23/64 a + 9 a + 23/64Solid-state timing module(100-ETA) on coil connection side b + 24 b + 15/16 b + 24 b + 15/16Solid-state timing module(100-ETB / 100-ETY) on coil connection side b + 24 b + 15/16 — —Mechanical interlock lateral on contactor a + 9 a + 23/64 a + 9 a + 23/64Interface on coil connection side b + 9 b + 23/64 — —Suppressor module on coil connection side b + 3 b + 1/8 b + 3 b + 1/8➋ Marking with Labeling sheet
Labeling sheet with coverLegend plate for V4 / V5 systemLegend plate for Bul. 1492W system
+ 0+ 0
+ 5.5+ 5.5
+ 0+ 0
+ 7/32+ 7/32
+ 0+ 0
+ 5.5+ 5.5
+ 0+ 0
+ 7/32+ 7/32
115˚
25˚5˚5˚
cc1
ø d
b
d1
d2a +...+...
+...
c2
c3
25˚ 25˚
5˚5˚
Dimensions are shown in millimeters
AC Control
DC Control
Mounting Position
8-68 Rockwell Automation
Product Selection - Page 8-54