Download - Ducted Split Unit

Transcript
Page 1: Ducted Split Unit

High StaticDucted Split

Authorized dealer:

Catalogue No: YSB-0212-B

Head Office: Tel: 03-7718 8388 Fax: 03-7727 4371 Email: [email protected], [email protected]

Branches: • Penang Tel: 04-331 1670 • Johor Tel: 07-557 7788 • Pahang Tel: 09-567 6778 • Perak Tel: 05-548 2307 • Melaka Tel: 06-288 1133 • Sabah Tel: 088-722 194 • Sarawak Tel: 082-333 299 • Negeri Sembilan Tel: 06-768 8969

Service Centre: • Alor Setar • Kota Bharu

Group Associated (C&L) Sdn Bhd (109719-M)

www.york.com.my

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI 210/240.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW: COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB / 23.9°C WB OUTDOOR4) EER CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ARI 210/240.5) * FOR PROJECT BASIS6) INDOOR UNIT DIMENSION, INDOOR WEIGHT, INDOOR AIR FLOW AND INDOOR FAN ESP IS FOR SINGLE SKIN ONLY.7) ESP ON TABLE ABOVE IS WITHOUT THE FILTER.

INDOOR UNITOUTDOOR UNITINDOOR UNITOUTDOOR UNITLIQUIDGAS

UNIT DIMENSION, HxWxD

UNIT WEIGHT

COPPER PIPE SIZE

TOTAL COOLING CAPACITY

INPUT POWERRUNNING CURRENT - 1Ø [3Ø]POWER SOURCEREFRIGERANT TYPE / CONTROLINDOOR AIR FLOWINDOOR FAN ESP (H/M/L)SOUND PRESSURE LEVEL (H/M/L)

MODELINDOOR UNIT (SINGLE SKIN)INDOOR UNIT (DOUBLE SKIN)*

YSB 125BYDSB 125B

125,00036,63511,910[21.57]

58

169

28.6 / 11/815.9 / 5/8

34.9 / 13/8

946 x 939 x 1,116 1,041 x 939 x 1,116

YSB 150B1YDSB 150B1

150,00043,96216,211[31.77]

59885 x 1,640 x 1,040 885 x 1,640 x 1,040

189227

YSB 100BYDSB 100BYDSB 80B

100,00029,30810,790[19.38]

57

164

380-415/3/50INDOOR TXV

572 x 1,502 x 761

102 176

70,00020,5167,109[13.58]

145

Btu/hWWA

V/Ph/Hz

dBAmm

l/s / CFMPa (in.wg.)

mm

mm/inmm/in

kg92

12.7 / ½25.4 / 1

56

YSB 80B

1,982 / 4,200149 / 0.6

2,171 / 4,600149 / 0.6

1,510 / 3,200100 / 0.4100 / 0.4

1,180 / 2,500

OUTDOOR UNIT MYSS 125B MYSS 150CMYSS 100BMYSS 72C* MYSS 80C80,00023,4478,083

[16.07]

946 x 1,300 x 500

INDOOR UNITOUTDOOR UNITINDOOR UNITOUTDOOR UNITLIQUIDGAS

COPPER PIPE SIZE

572 x 892 x 761

MODEL

INDOOR UNIT (SINGLE SKIN)INDOOR UNIT (DOUBLE SKIN)*

TOTAL COOLING CAPACITY

INPUT POWERRUNNING CURRENT - 1Ø [3Ø]

852 x 1,030 x 400

POWER SOURCEREFRIGERANT TYPE / CONTROLINDOOR AIR FLOWINDOOR FAN ESP (H/M/L)SOUND PRESSURE LEVEL (H/M/L)UNIT DIMENSION, HxWxD

UNIT WEIGHT

YSB 60B-

61,00017,8786,672

[10.46]

61572 x 1,502 x 761

85108

YSB 50B-

50,00014,6545,457[9.08]

53

55104104

380-415/3/50INDOOR CAP. TUBE

12.7 / ½

35,00010,2583,49316.42

220-240/1/50

Btu/hWWA

V/Ph/Hz

l/s / CFMPa (in.wg.)

dBAmmmm

mm/inmm/in

kg

YSB 40B-

53

50

9.5 / 3/8

OUTDOOR UNIT YSL 61DYSL 50DYSL 35D YSL 40D40,00011,7234,833[7.27]

95

19.1 / 3/4

100 / 0.4590 / 1,250

100 / 0.4755 / 1,600 944 / 2,000

INDOOR UNITOUTDOOR UNITINDOOR UNITOUTDOOR UNITLIQUIDGAS

COPPER PIPE SIZE

INPUT POWER

POWER SOURCEREFRIGERANT TYPE / CONTROL

SOUND PRESSURE LEVEL (H/M/L)UNIT DIMENSION, HxWxD

UNIT WEIGHT

RUNNING CURRENT - 1Ø [3Ø]

MODELINDOOR UNIT (SINGLE SKIN)INDOOR UNIT (DOUBLE SKIN)*

TOTAL COOLING CAPACITY

YSB 350B3

350,000102,57936,280[76.57]

661,546 x 2,122 x 1,199

440164 169 x 2

28.6 / 11/8 34.9 / 13/8

YSB 300B2

300,00087,92534,688[66.50]

66

343227 x 215.9 / 5/8

380-415/3/50INDOOR TXV

(946 x 939 x 1,116) x 2 (946 x 939 x 1,116) x 2 946 x 939 x 1,116 (946 x 939 x 1,116) x 2(1,041 x 939 x 1,116) x 2

34.9 / 13/8

1,291 x 1,866 x 1,199

YSB 200B2

200,00058,61720,710[38.7]

61945 x 1,894 x 980

220164 x 2

28.6 / 11/8

Btu/hWWA

V/Ph/Hz

dBAmmmm

mm/inmm/in

kg

YSB 250B2YDSB 350B3YDSB 300B2YDSB 200B2 YDSB 250B2

OUTDOOR UNIT MYSS 100B MYSS 125Bx2MYSS 150C x 2MYSS 100B x 2 MYSS 125B x 2250,00073,27124,510[44.30]

63

343169 x 2

INDOOR AIR FLOWINDOOR FAN ESP (H/M/L)

l/s / CFMPa (in.wg.)

4,956 / 10,500200 / 0.8

4,248 / 9,000200 / 0.8158 / 0.6

3,021 / 6,400200 / 0.8

3,776 / 8,000

INDOOR UNITOUTDOOR UNITINDOOR UNITOUTDOOR UNITLIQUIDGAS

COPPER PIPE SIZE

RUNNING CURRENT - 1Ø [3Ø]POWER SOURCEREFRIGERANT TYPE / CONTROLINDOOR AIR FLOWINDOOR FAN ESP (H/M/L)SOUND PRESSURE LEVEL (H/M/L)UNIT DIMENSION, HxWxD

UNIT WEIGHT

MODELINDOOR UNIT (SINGLE SKIN)INDOOR UNIT (DOUBLE SKIN)*

TOTAL COOLING CAPACITY

INPUT POWER

YSB 750B5

750,000219,81289,420

[169.10]

712,257 x 2,274 x 1,905

1,051

YSB 600B4

600,000175,85072,516

[136.68]

701,978 x 2,274 x 1,905

991

34.9 / 13/815.9 / 5/8

(946 x 939 x 1,116) x 2 (946 x 939 x 1,116) x 2 (946 x 939 x 1,116) x 4 (1,041 x 939 x 1,116) x 5(1,041 x 939 x 1,116) x 4

380-415/3/50INDOOR TXV

227 x 4 227 x 5

YSB 500B4

450,000131,88746,855

[100.42]

164 x 2 169 x 2

28.6 / 11/8 34.9 / 11/8

Btu/hWWA

V/Ph/Hz

dBAmm

l/s / CFMPa (in.wg.)

mm

mm/inmm/in

kg

68

564

1,546 x 2,274 x 1,466

YSB 500B4--YDSB 500B4 YDSB 500B4

OUTDOOR UNIT MYSS 150C x 5MYSS 150C x 4MYSS 100Bx2 MYSS 125Bx2 MYSS 125B x 4500,000146,54249,715[89.34]

10,619 / 22,500350 / 1.4

8,496 / 18,000300 / 1.2

7,080 / 15,000250 / 1.0

7,080 / 15,000250 / 1.0

169 x 4

YSB 400B4

400,000117,23340,795[76.1]

661,546 x 2,274 x 1,466

513164 x 4

28.6 / 11/8

(946 x 939 x 1,116) x 4

YDSB 400B4MYSS100B x 4

5,664 / 12,000200 / 0.8

Page 2: Ducted Split Unit

Cabinet ConstructionBoth indoor and outdoor are coated with weatherproofed electro galvanized mild steel casing, with an epoxy is coated with an epoxy polyester powder costing for severe external conditions. Service panel is available at the convenience side for both indoor and outdoor.

Modular CombinationWith only 7 different capacities outdoors, YORK ducted split product range is ranking up to an individual indoor unit at 750kBtu/h.

Wide Product RangeYORK ducted split is offering very wide range of product lineup which is applicable from residential, to light commercial or even commercial use.

InsulationFire-resistant Polyethylene is used at every possible condensate panel to prevent all forms of water or moisture penetration. Polyethlene, which is also a type a Closed Cell Foam Insulation (CCF) has offered the following advantages: • Durable external surface that resists dirt tough and resilient.• Higher degree of puncture resistance when compared to fiberglass.• Easily cleaned surface (if necessary) to further resist microbial growth.

Safety Fearures• High pressure and low pressure protection• Phase sequencer is used to detect for any wrong phase and phase loss during installation and operation.• Compressor & motor current overload protection.• Minimum compressor's running time to ensure oil return.

Components• Compressor:

Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimize vibration.

• Indoor Fan: A dynamically balanced forward curved fan with a field changeable pulley package, in order to match the designed supply air requirements.

Changeable Drive PackageNon-standard external static pressure & airflow requirement can be sized by changing the factory fitted drive package. (for belt drive model only)

Easy To Reach Access ValveDischarge line and suction line access valve is accessible without opening the unit casing.

Indoor Air Throw DirectionWith the choices of vertical and horizontal air throw make it versatile to various architectual design.

The Trusted Quality And Name In Air-Conditioning

This unprecedented innovation is brought to you by YORK - the trusted name in air-conditioning for quality and reliable after-sales-service. With a nationwide service network. YORK is ever ready to take you to a new dimension in cooling comfort.

100% coil leak test by helium testing method and every components being used in YORK unit are tested, at R&D test lab, which is registered under ISO standard and recognised by Sirim.

Copper tubes were tested at burst pressure, where it is at least 3 times the refrigerant operating pressure.

Every unit receives a 100% unit run test before leaving the production line in the facrtory, which is registered under ISO standard and recognised by Sirim.

System FeaturesYSB 750B5

YSB 600B4

YSB 350B3

YSB 200B2

YSB 125B/150B

YSB 250B2/ 300B2/ 300B3

YSB 400B4 /500B4

YSB 60B/ 80B/ 100B

YSB 40B/ 50B


Top Related