FLOW BETTERWITH PLEURAFLOW® ACTIVE CLEARANCE TECHNOLOGY™
DON'T LET YOUR CHEST TUBE BLOCK YOUR PATIENT’S RECOVERY.
More than 36% of patients su�er from blocked chest tubes.
Blocked chest tubes can lead to Retained Blood Complications in your patients.
Retained Blood Complications (RBC) causes multiple
mechanical and inflammatory complications that may lead
to additional interventions and readmissions.2,3
A recent prospective study found that of these failures,
86% are intra-thoracic and invisible to bedside caregivers1.
The crucial hours post-surgery, when the patient is still
bleeding, are vitally important. Why risk patient outcomes
on a conventional chest tube to evacuate blood from the
surgical site?
Patient outcomes and healthcare costs are seriously impacted by RBC.
hours days weeks months years
3-6%pericardial tamponade,hemothorax
*References available upon request.
ACUTE
9-12%bloody pleural (9-12%) and pericardial (2%) e�usions
SUB-ACUTE
2-3%constrictive pericarditis, fibrothorax
CHRONIC
COST OF CARE
16-23% combined
Complications Requiring Intervention*
LENGTH OF STAY MORTALITY RATE
Unreimbursable Costs Per Patient with RBC4
$28,814per RBC
5.8 days doubledIncrease 3% to 6%
INCREASE55% 2x2x
BLOCKED TUBES LEAD TO COMPLICATIONS
Improve Patient SafetyBy eliminating accumulated blood and
fluid at the surgical site, you reduce risky and unwanted complications.
Plus, you will never again have to break
sterility in order to clear a clogged tube.
Minimize Patient DiscomfortOur 20FR PleuraFlow removes nearly triple
the amount of blood than a traditional
32FR drain5 (525 ml vs. 183 ml) and your
patients will benefit from a smaller and more flexible silicone tube.
Reduce Hospital CostsPrevention of a single Retained Blood
Complication incident may cover the
cost of using PleuraFlow ACT in 100
cardiac surgery patients.4
Clearance Loop enables
proactive clearance of
thrombus obstruction from
the chest tube and provides
real-time patency feedback.
KEEP CHEST TUBES CLEARwith PleuraFlow® Active Clearance Technology™ (ACT)Developed by cardiac surgeons, PleuraFlow ACT is a unique system that
proactively clears chest tubes and prevents the retention of blood in the chest cavity. ACT technology is used to maintain tube patency and
clears the pathway to a successful recovery before and after discharge.
EU Authorized Representative:
Emergo EuropeMolenstraat 152513 BH, The HagueThe Netherlands
Manufactured For:
ClearFlow, Inc.1630 S. Sunkist St., Suite E Anaheim, CA, US, 92806
ML004-F
Copyright © 2014 ClearFlow, Inc. All Rights Reserved.
™ Trademarks and ® Registered Trademarks of ClearFlow, Inc. US Patents 7,854,728, 7,951,243, 8,048,233, 8,246,752, 8,388,759, and 8,702,662. International Patents AU 2004235782; CA 2,427,628, CA 2,565,303. Other US and international patents pending.
US FDA 510(k): K093565; Health Canada License Number 82994; ARTG Identifier 218317
1 Karimov, J.H., Gillinov, A.M., Schenck, L., et al. Incidence of chest tube clogging after cardiac surgery: a single-centre prospective observational study. Eur J Cardiothorac Surg. 2013;44(6):1029-1036. doi:10.1093/ejcts/ezt140.
2 Shiose, A., Takaseya, T., Fumoto, H., et al. Improved drainage with active chest tube clearance. Interact CardioVasc Thorac Surg. 2010;10:685-688. doi: 10.1510/icvts.2009.229393.
3 Dixon, B., Santamaria, J.D., Reid, D., et al. The association of blood transfusion with mortality after cardiac surgery: cause or confounding? Transfusion. 2013;53(1):19-27. doi: 10.1111/j.1537-2995.2012.03697.x.
4 2010 Nationwide Inpatient Sample (NIS), from the DHHS Agency for Healthcare Research and Quality (AHRQ) Healthcare Cost and Utilization Project (HCUP). Data extracted using ICD-9 codes from over 313,000 US adult heart surgery patients. Analysis performed by Fletcher Spaght, Inc.
5 Arakawa, Y., Shiose, A., Takaseya, T. et al. Superior Chest Drainage With an Active Tube Clearance System: Evaluation of a Downsized Chest Tube. Ann Thorac Surg. 2011;91:580-583. doi: 10.1016/j.athoracsur.2010.10.018.
References
ACT NOWImprove Outcomes, Lower Costs
Learn more about the innovative new
technology of PleuraFlow® Active
Clearance Technology™ (ACT).
Contact your local representative:
* PleuraFlow ACT System includes a straight silicone chest tube
and clearance apparatus.
CODE DESCRIPTION
20FR PleuraFlow ACT System*
24FR PleuraFlow ACT System*
28FR PleuraFlow ACT System*
32FR PleuraFlow ACT System*
Ordering Information
PF-20
PF-24
PF-28
PF-32
www.clearflow.com