Diameter
thgi
eH
VR SERIESEXPANSION TANKS
Use: Expansion vessels with replaceable membrane for closed heating systems.
Working temperature -10 + 100 C External �nish colour RAL 3000RED
Rubber membrane EPDM
Model Height (mm) Diameter (mm) Maximum working Precharge Connectionpressure (bar) pressure (bar) (inch / location)
VR8VR12VR18VR24VR35
316 200 8 1.5 3/4" Top295 280 8 1.5 3/4" Top423 280 8 1.5 3/4" Top489 280 8 1.5 3/4" Top440 365 8 1.5 3/4" Top
A UASYSTEMR
SYDNEY Head | Unit 1, 33 Maddox Street Alexandria NSW 2015 AustraliaPhone: 61 2 8338 8660 Fax: 61 2 8338 8661Email: [email protected]
MELBOURNE 34 Strong Avenue Thomastown VIC 3074 Australia Phone: 61 3 9462 6700 Fax: 61 3 9462 6711
www.simonsboiler.com.au
A UASYSTEMR
Diameter
thgi
eH
VRV SERIES
EXPANSION TANKS
Use: Expansion vessels with replaceable membrane for closed heating systems.
Working temperature -10 + 100 C External �nish colour RAL 3000RED
Rubber membrane EPDM
Model Height (mm) Diameter (mm) Maximum working Precharge Connectionpressure (bar) Pressure (bar) (inch / location)
VRV50VRV60VRV80VRV100VRV120VRV150VRV200VRV250VRV300VRV400VRV500VRV600
564 365 8 1.5 3/4" Top668 365 8 1.5 3/4" Top687 410 8 1.5 1" Top663 495 8 1.5 1" Top733 495 8 1.5 1" Top795 550 8 1.5 1" Top1085 600 8 1.5 1" Bottom1051 650 8 1.5 1" Bottom1212 650 8 1.5 1" Bottom1198 750 8 1.5 1 1/4" Bottom1438 750 8 1.5 1 1/4" Bottom1634 750 8 1.5 1 1/4" Bottom
SYDNEY Head | Unit 1, 33 Maddox Street Alexandria NSW 2015 AustraliaPhone: 61 2 8338 8660 Fax: 61 2 8338 8661Email: [email protected]
MELBOURNE 34 Strong Avenue Thomastown VIC 3074 Australia Phone: 61 3 9462 6700 Fax: 61 3 9462 6711
www.simonsboiler.com.au
EXPANSION KIT WITH R.P.Z.A - EXPANSION TANKB - AUTOMATIC FILL VALVEC - ISOLATING VALVED - AIR SEPERATORE - AUTOMATIC AIR VENTF - 300 kPa PRESSURE RELIEF VALVEG - CONNECTION POINT FOR AUTOMATIC REFILL UNIT APU.01
OR
AIRSTOP
OR
1/2
OR
1/2
TO SYSTEMRETURN
COLDFEED
BC
EF
G
A
D
R.P.Z.
FLOW RETURN
BOILER OR CHILLER
PUMP
Back w preventionsupplied separately
AQUASYSTEM MODELS VRV 200 TO VRV 600ARE BOTTOM CONNECTIONS.THESE MODELS REQUIRE PIPING BETWEENBOTTOM CONNECTION AND EXPAK ASSEMBLY
AQUASYSTEM MODELS VR 8 TO VRV 150ARETOPCONNECTIONS.THE EXPAK CAN BE SCREWED DIRECTLY TO THE TOPOF THE EXPANSION TANK.
A UASYSTEMR
A UASYSTEMR
SYDNEY Head | Unit 1, 33 Maddox Street Alexandria NSW 2015 AustraliaPhone: 61 2 8338 8660 Fax: 61 2 8338 8661Email: [email protected]
MELBOURNE 34 Strong Avenue Thomastown VIC 3074
Australia Phone: 61 3 9462 6700 Fax: 61 3 9462 6711
www.simonsboiler.com.au
OR
AIRSTOP
OR
1/2
OR
1/2
COLDFEED
BC
EF
G
A
D
TO SYSTEMRETURN
R.P.Z.
CONNECTION PIPE BY OTHERS
A UASYSTEMR