MYSONDecor VN Radiator Series Installation & Technical Guide
02
DECOR.DECOR radiators stand for aesthetically sophisticated Design, combined with
technologically perfect heating. They were conceived with all areas of installation and use in
mind.
Radiators
03040506070809
10 - 12
Ko
nte
c B
asi
cs
Myson, Inc. Limited Warranty
Myson, Inc warrants the following products against defects in material and workmanship to the original owner for the duration listed from date of installation or three months after date of shipment, whichever comes first.
The remedy in all cases shall be to repair or replace the product at Myson’s discretion upon verification of a factory defect. If replacement is required, and an exact replacement product is no longer available, Myson reserves the right to furnish a similar product of equal value.
NO REMOVAL, SHIPPING OR INSTALLATION EXPENSES ARE REIMBURSIBLE
The original purchaser is responsible for determining the suitability of the Myson product for their installation. Installation and troubleshooting should be performed by a competent technician with knowledge of hydronic heating and/or basic electricity.
Damages occurring during shipment, transit, storage or handling, abuse, neglect, accident, misapplication, incorrect power line voltage, mproper water source or connection, fire, flood or other Acts of God are not covered. Freight damage claims MUST be made within 10 days of receipt from Myson. No Exceptions.
STEEL PANEL RADIATORS -- SELECT, T6, DÉCOR, COLUMN AND BENCH
The duration of warranty for steel panel radiators is 5 Years.
• Painted finishes will not peel or flake from the surface of the radiator• The body of the radiator and its welded joints will not leak when the product is properly installed and maintained
according to Myson's instructions.
What is not covered:
• Rust occurring from improperly sealed threaded connections or oxygen corrosion
• Electrolytic corrosion caused by failure to flush the system properly after initial installation
Contents
What is covered:
Important information Product description Model overview / connection dimensions Piping & rough-inWelded bracket positions Mounting and wall-clearance Decor 2H baseboard mounting detail / Start-up & MaintenanceHeating outputs / weights / water contentPiping arrangementsValve selection
1314
Important Information 03
BEFORE YOU BEGIN
SAFETY PRECAUTIONSRadiators are hot when in use, and as such, present a risk of burns to users on prolonged contact. The temperature of aradiator is dependent on the temperature of the system water, as set by the system installer or user. Installers and usersshould ensure that those who may come into close proximity to hot radiators are aware of the risk of burns. Installersand users should take all necessary steps to minimise the risks of burns. If the risk is significant, consideration should begiven to installing low surface temperature radiators, or to placing guards in front of the radiators.
For the correct installation of radiators it is essential that the fixing of the radiator is carried out in such a waythat it is suitable for intended use AND predictable misuse. A number of elements need to be taken intoconsideration including the fixing method used to secure the radiator to the wall, the type and condition of the wallitself, and any additional potential forces or weights that may happen to be applied to the radiator, prior tofinalising installation. IN ALL CASES IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIEDPROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
INTRODUCTIONThe Myson Décor Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase of the Décor Radiator. Each radiator combines Myson’s compact design and advanced steel construction with a durable baked epoxy/polyester enamel powder coat finish. Myson’s sleek styling and thorough testing provides attractiveness anddependability. Myson’s goal is to assure the highest performance, quality, reliability and outstanding customer service.
CAUTIONStep 1 Read this entire instruction manual thoroughly before beginning installation.
Step 2 To ensure full efficiency of your Myson Décor Steel Panel Radiator, please follow all the instructions carefully .
Step 3 Failure to follow these instructions will invalidate the manufacturer’s warranty.
APPLICATIONMyson radiators are only for use in recirculating closed loop hydronic-heating systems. These radiators are not recom-mended for gravity systems. DO NOT USE STEAM IN THESE RADIATORS.
INSPECT FOR DAMAGENOTE: Inspect materials for concealed shipping damage. You only have 11 days to file a freight claim. If items are damaged or missing, please call Myson at 1-800-698-9690.
INSPECTION FOR COMPLETENESSUnpack the Décor Radiator carefully to avoid damage or loss of parts. The Décor Radiator will come with the following parts:
• Wall brackets
• Plastic inserts for noise suppression
• Stainless steel solid plug
• Vent plug
IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONALINSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
Myson products are designed to be installed by professional tradespeople. Myson instructions are meant to be thorough; however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade practices, and proper use of the tools of the trade. Should a homeowner without such knowledge or skill take it upon him/herself to attempt the installation, Myson will not be responsible for any damages, injuries or unsatisfactory performance of the Myson product used.
DESIGN AND LAYOUT CONDITIONSMyson Décor Radiators should only be used with a recirculation pump closed loop hydronic heating system. Please consult national and local codes for specific restrictions that may be imposed on your installation. Position your radiator away from your circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that could draw air into the system. The preferred positioning for the Décor radiator is below a window where it can minimize downdrafts from glazed areas.
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
Radiators
DECOR convectors and horizontal heating panels are radiators in fully welded designs, with either 1 to 5 layers of steel rectangular water-flow tubes arranged one-behind-the-other (for convectors), or 1 or 2 such layers (for horizontal heating panels). In each layer, the convectors have between one and four tubes arranged one-above-the-other; the horizontal heating panels have from 2 to 11 tubes.
DECOR vertical heating panels consist of 1 or 2 layers of steel rectangular water flow tubes, arranged one-be-hind-the-other, with 6 to 10 steel pipes, arranged side-by-side.
A 5/62" space between the heating pipes guarantees additional resistance to corrosion. DECOR convectors and horizontal heating panels come with side panels and top covers; DECOR
vertical heating panels come with side panels. DECOR heating panels are delivered with welded mounting bra-ckets. (Except the 2H)
All DECOR convectors and heating panels are also delivered with factory-sealed drain plugs and pivotable vent plugs. (Exception: bottom-opposite-end connection models come with a dummy plug instead of the drain plug.)
Standard design: rectangular steel tubes 2-3/4" x 7/16" x 16 ga. High-pressure design: rectangular steel tubes, 2-3/4" x 7/16" x 14 ga.
Baseboard dimensions: 2HOverall lengths: between 23-5/8 inches and 118-1/8 inches Overall height: 5-9/16 inches (2 panels)
Horizontal radiator dimensions: 3H - 11HOverall lengths: between 23-5/8 inches and 94-1/2 inchesOverall heights: between 8-7/16 inches (3 panels) and 31-1/8 inches (11 panels)
Vertical radiator dimensions: 5V - 10VOverall lengths of: 14-1/8, 16-15/16, 22-5/8, and 28-1/4 inches Overall height: 78-3/4 inches
Coatings:1. Undercoat: electrophoretic, using water-soluble paints,
conforming to DIN 55900 part 1, stoved at 329° F; 2. Finish: electrostatic powder coating, conforming to DIN 55900 part 2,
in a state-of-the-art facility. (On request, and at a supplementary charge, a range of RAL and sanitary ware colours can be offered.) This particularly robust coating is stoved at an object temperature of 356° F.
Packaging: 1. Cardboard packaging2. Edge protection3. Shrink foil
DECOR product descr ipt ion
Quality certif icates
MYSON offers its customers strong brands that meet highest quality standards. All the production sites’ production processes are certifi ed ac-cording to ISO. The quality and perfor-mance specifications of the convectors and heating panels have been verifi ed by recognised European institutions.
The standards that the quality certifi -cates require us to maintain give you security, the best heating performance and premium product quality. For the MYSON warranty conditions, please refer to the table of contents page of this manual.
Strong brands of the highest quality
Connections:2 x internal thread G 1/2“ BSP, welded-in for supply and return. Vent and drain plugs (or dummy plug) are factory sealed and are fi tted according to the customer’s specifi cations.
Maximum positive operating pressureStandard design: 72 psi
Maximum positive operating pressure: High-pressure design Special Order(supplementary charge): 116 psi
Maximum operating temperature: 230° Fm
ax.
72psimax.
116psimax.
04
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
P R O D U C T D E S C R I P T I O N 6 H 2 2 0 9 0
Overall Length [mm]
Number of Convector Rows [depth]
Number of Panel Rows [depth]
Panel Orientation Horizontal/Vertical
Number of Panels
Additional sizes and models are available as special order
DECOR model overview / connect ion dimensions
Overall height [in]
Horizontal & Vertical design, H & V models
**100 **120 **140 **160 **180 **200 **220 **240
23-5/8" 31-1/2" 35-7/16" 39-3/8" 47-1/4" 55-1/8" 63" 70-7/8" 78-3/4" 86-5/8" 94-1/2"Overall length
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
Sid
e C
on
ne
ctio
ns:
All Dimensions are nominal
05
H34
6-7/8"
1-7
/8"
H11 1"
H22 1-7
/8"
3-11/16"
Tapping spacing [in]
2-11/16"
8-7/16"
5-5/8"
11-1/4"
16-15/16"
22-5/8"
31-1/8"
Overall Heights Overall Lengths
22-5/8" 31-1/8"
21" 29-1/2"
2-11/16"
V11
78
-3/4
"
V111
"3/16"3/16"
2-11
/16"
Model Height 8H 11H
13/16" Typical
Overall Length
Overall length
Vertical Model 6V11 8V11 10V11
16-15/16" 22-5/8" 28-1/4"
2H 3H 4H 6H
5-5/8" 8-7/16" 11-1/4" 16-15/16"
4" 6-7/8" 9-9/16" 15-3/8"
Model Length **060 **080 **090
76
-3/4
"
5V11
14-1/8"
**300
118-1/8"
DECOR piping & rough-in
H and V models
Suitable for mono-flo, home run or 2-pipe systems
Top-bottom, opposite-end, side-connection, right-side supply
Top-bottom, opposite-end, side-connection, left-side supply*
Bottom-only, opposite-end, side-connection, right-side supply
Note: 5% reduced heat output
Rough-in dimension shown at right is for a TRV and a LKD valve or a pair of LKD valves. When using FF valves add 3-5/8" to overall length.
Recommendation: Radiator tappings and valve spuds are 1/2"BSP. Professional expertise is required when sealing these "straight" threads. Failure to properly seal the connections will result in leaks resulting in property damage.
NOTE ! Myson is not responsible for damage resulting from improper workmanship.
NOTE ! Rough-in information is given for Myson control valves. Valve specifications vary by manufacturer. Myson will not be responsible for damage or repair of property resulting from the use of non-Myson valves.
06
*Plug & Vent location as shipped:
V
P
V
P
V P P V
Overall Length + 3-1/2"
LKD16AN FF16WAC TRV
• All installations require 2 valves per radiator
• All valves are ½” BSP thread for connection to theradiator and ½” NPT thread for connection to thesystem (also includes compression nut and ferrulefor connection to ½” copper)
• Valves are available in 3 basic patterns: angle,straight, and inverted angle (TRV only)
• Basic Installation: use 2 – LKD16AN (angle) orLKD16SN (straight) manual valves, nickel plated withscrewdriver stops and caps
• Basic upgrade: use 1 - FF16WAC and 1 - FF16LACmanual valves, angle only, chrome plated with whitehandles (FF16WAC is adjustable for balancing,FF16LAC is fixed open but can be closed for service)
• TRV (thermostatic radiator valves) are available forautomatic temperature control of individual radiators:available in 3 body patterns, with or withoutthermostatic head (sensor), use in conjunction withLKD or FF
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
Bottom-only, opposite-end, side-connection, left-side supply
Note: 5% reduced heat output
NOTE: See page 8 for rough-in from finished wall to pipe centers.
See page 14 for additional valve information
DECOR welded bracket posit ion
H models
H11/H22 L-BRACKET 300
Overallheight
8-7/16"
Overallheight
11-1/4"
23-5/8" - 78-3/4"
A A
3-3/8"
4-3/4"
A A1/2 1/2
86-5/8" - 94-1/2"
5-1/8"
4-3/4"
23-5/8" - 78-3/4"
A A
1-9
/16
"
A A
86-5/8" - 94-1/2"
1/2 1/2
1-9
/16
"
2-3/8"
9/1
6"
H11 H22
07
H11/H22 L-BRACKET 400
Overallheight
16-15/16"
5-1/8"
8-11/16"
23-5/8" - 78-3/4"
A A A A
86-5/8" - 94-1/2"
1/2 1/2
Overallheight
from22-5/8"
to31-1/8"
5-1/8"
16-1/2"
23-5/8" - 78-3/4"
A A
130
420
A A
86-5/8" - 94-1/2"
1/2 1/2
H11/H22 L-BRACKET 600
A = 6-5/16"
1-9
/16
"
2-3/8"
9/1
6"
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
DECOR bracket posit ions
V11 H11 H22 models
WA 11Bracket
2-3/8" 9/1
6"
08
16-15/16" - 28-1/4"
78
-3/4
"
5-1/
8"
4-1/4"4-1/4"
3-9
/16
"
1-9
/16
"
Model V11 WA11-BRACKET
1-3/4"
70
-1/1
6"
H34 pedestal model Floor Stand KOMFOOT-1: posit ioning
KOMFOOT-1
H34
Measurement X: chosen distance between the wall or window surface and the back of the convector.
5-7/8" 5-7/8"
1/2overall length
6-9
/16
"
6-7
/8"
X
3-1
/2"
1/2 overall length
constantconstant
H11/H22 L-BRACKET
Note: For an overal l length of 86-5/8" and greater, a 3rd stand console must be used!
W
Measurement W H11 = 1-11/16" H22 = 3-7/16"
PLEASE NOTE: The brackets provided are only intended for installation on walls made of solid wood, bricks, concrete or on timber-frame stud walls where the fixing is into the timber. For walls made of other materials, for example hollow bricks, please consult your installer and/or specialist supplier. ONCE AGAIN, IF YOU ARE UNSURE, IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
4" Minimum L-Bracket
XMeasurement X H11 = 3-3/8" H22 = 5 -1/4"
3-3/8"
Note: For H11 and H22 models with an overal l length of 86-5/8" and greater 3 brackets are required.
Note: For more detai led L-bracket instal lat ion dimensions and mounting posit ions please consult the Assembly Instruct ions included with the mounting brackets.
Note: The L-Bracket is not for use with 2H11 model. please refer to page 09 for 2H11 mounting detai ls .
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
DECOR model 2H Baseboard mounting detai l / Start-up & Maintenance
Horizontal & Vertical design, H & V models
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
09
2H11 1"
2-11/16"
5-5/8" 4"
3-3/16" Minimum
1-7/16"
3-1/8"
BBCB Bracket
BBWB Bracket
BBWB shown with foam spacer typical on all lower bracket locations.
Rear view of typical upper and lower bracket (BBCB + BBWB) locations.* Upper brackets should be fastened to studs or blocking**when installed on frame construction. * Upper brackets should be installed at a recommended minimum of 32" intervals. * Lower brackets with foam backer used for bottom of panel standoff should be spaced between upper brackets as required.
Failure to flush system of debris and flux may cause premature radiator failure, which can result in leaks and property damage NOT covered under the Myson Warranty.
Step 1 Fill and vent the system.
Step 2 Run the system for two (2) hours at full temperature with all radiator valves in the open position.
Step 3 Shut off and drain the system while the water is still hot.
Step 4 Refill the system.
Step 5 Reheat, vent, and balance the system.
Step 6 Once the Décor Radiator is filled with water the system should be left filled.
Step 7 System should be checked for leaks on seasonal start-ups. Leaks must be repaired as automatic system fill valves allow fresh water/oxygen into the system attacking radiators internally.
SYSTEM START-UP
MAINTENANCE & CLEANING1 Once operating, avoid the introduction of fresh water and oxygen to the system to prevent corrosion.
2 An occasional wiping with a damp cloth using a non-abrasive detergent can protect the finish of yourMyson Décor Panel Radiator.
3 The use of abrasive cleaners will damage the surface of your radiator and void the manufacturer’s warranty.
DECOR heat ing outputs 10
Heating output as calculated using an AWT shown and EAT of 70° F
8-7/16"
11-1/4"
2H11
4H11
5-5/8"
Overall depth
2-11/16"
Mode l
Overallheight
Overalllength
47-1/4"
55-1/8"
70-7/8"
86-5/8"
94-1/2"
23-5/8"
35-7/16"
Model
16-15/16"
6H11
963
1445
Output [btuh] 180° F 160° F 140° F
691 1235
1852 1037
2469 1926
16132881
1383
2247
3704
2535
2889 2074
4527 3531
3852 27654938
Output [btuh]
1216
1828
180° F 160° F 140° F
873 1558
2343 1312
3122 2436 1749
4681
3205
3651 2621
5724 4464
4871 34976245
Output [btuh]
1513
2269
180° F 160° F 140° F
1086 1940
2909 1629
3879 3026 2172
5825
3984
4543 3262
7144 5549
6056 43487764
Output [btuh]
2252
3002
180° F 160° F 140° F
1617 2887
3849 2155
4811 3753
37726736
2694
5254
8660 6755 4850
118-1/8" 4815 34576173
63" 3292 2568 1844 4160 3244 2329
5174 4036 2898
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
Watercontent gals.
Weight lbs.
Watercontent gals.
Weight lbs.
10.28 .18
.26
.35
.40
.46
.52
.63
.69
.87
15.00 .26
.39
.52
.70
.78
.95
1.04
3H11
Overall depth
2-11/16"
Overallheight
Overalllength
47-1/4"
70-7/8"
86-5/8"
94-1/2"
23-5/8"
35-7/16"
63"
31-1/2"
39-3/8"
Watercontent gals.
Weight lbs.
19.20 .36
.53
.71
.95
1.06
1.30
Watercontent gals.
Weight lbs.
26.27 .52
.69
.87
1.22
1.56
1.42
55-1/8"
__ __ __ __ __
__ __ __ __ __
__ __ __ __ __
__ __ __ __ __
__ __ __ __ __
__ __ __ __ __
__ __ __ __ __
__ __ __ __ __
__ __ __ __ __
__ __ __ __ __
22.33
44.65
54.57
59.54
39.69
29.77
28.81
38.42
51.22
57.62
70.43 76.83
35.03
43.79
61.30
78.82
23.98
27.41
30.83
37.68
41.11
51.38
20.55
15.42
DECOR heat ing outputs 11
Heating output as calculated using an AWT shown and EAT of 70° F
Overall
depth 2-11/16"
Overallheight
Model
Overalllength
23-5/8"
31-1/2"
39-3/8"
55-1/8"
70-7/8"
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
Overall
depth 2-11/16"
Overallheight
22-5/8" 31-1/8"
Model 8H11 11H11
Overalllength
23-5/8"
31-1/2"
39-3/8"
55-1/8"
70-7/8"
2731
3639
Output [btuh]
180° F 160° F 140° F
1960 3501
4665 2613
5830 4548
45708160
3265
6365
10496 8187 5878
Output [btuh]
3274
4365
180° F 160° F 140° F
2350 4147
5596 3134
6995 5456
54849793
3917
7639
12591 9821 7051
Watercontent gals.
Weight lbs.
34.59 .71
.95
1.18
1.66
2.13
Watercontent gals.
Weight lbs.
44.39 .97
1.29
1.62
2.26
2.91
22-5/8"
8H22
16-15/16"
6H22
4207
5606
Output [btuh]
180° F 160° F 140° F
3021 5394
7187 4025
8988 7010
704512581
5033
9813
16175 12616 9058
4985
6650
Output [btuh]
180° F 160° F 140° F
3579 6391
8526 4744
10654 8310
835314917
5966
11635
19180 14960 10741
Watercontent gals.
Weight lbs.
48.86 1.06
1.42
1.77
2.48
3.19
Watercontent gals.
Weight lbs.
64.85 1.42
1.89
2.36
3.31
4.25
46.12
57.65
80.70
103.76
59.19
74.00
103.58
133.18
65.14
81.43
114.00
146.57
86.47
108.09
151.32
194.55
Heating output as calculated using an AWT shown and EAT of 70° F
DECOR heat ing outputs 12
Overall depth 3-11/16"
Overallheight 31-1/8"
Model
Overalllength
23-5/8"
31-1/2"
39-3/8"
55-1/8"
70-7/8"
5-5/8"
2H34
Overall depth 6-7/8"
Overallheight[less feet]
Model
Overalllength
39-3/8"
55-1/8"
70-7/8"
86-5/8"
11-1/4"
4H34
Output [btuh]
5909
7877
180° F 160° F 140° F
4242 7575
10098 5655
12621 9845
989417667
7068
13780
22720 17721 12723
7258
Output [btuh]
180° F 160° F 140° F
3722 6647
9306 5211
11964 9332
818914623
6700
11406
8508
11910
Output [btuh]
180° F 160° F 140° F
6108 10907
15629 8551
19630 15312
1343923998
10993
18719
Note: H28 Pedestal models require KOMFOOT-1 feet for instal lat ion.
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
Watercontent gals.
Weight lbs.
83.45 1.94
2.58
3.25
4.52
5.81
78-3/4"
V11
4424
5901
Output [btuh]
180° F 160° F 140° F
3176 5671
7565 4237
9459 7378 5298
4719 3681 2643
Watercontent gals.
Weight lbs.
58.30 1.32
1.58
2.11
2.63
Overall depth 2-11/16"
Overallheight
Overalllength
14-1/8"
16-15/16"
22-5/8"
28-1/4"
Watercontent gals.
Weight lbs.
52.77 .87
1.22
1.56
1.91
Watercontent gals.
Weight lbs.
102.38 1.79
2.48
3.19
3.90
11H22
5185
111.26
139.07
194.70
250.33
69.90
93.38
116.59
73.87
94.98 116.08
143.33
184.28
225.23
Model
Typical hydronic system types
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
13
The following drawings are general examples. Consult a certified heating professional for your specific application.
DECOR optional piping arrangements
DECOR valve select ion
Valve application
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
14
All installations require 2 valves per radiator
All valves are ½” BSP thread for connection to the radiator and½” NPT thread for connection to the system (also includes compression nutand ferrule for connection to ½” copper
Valves are available in 3 basic patterns: angle, straight, and inverted angle (TRV only)
Basic Installation: use 2 – LKD16AN (angle) or LKD16SN (straight)manual valves, nickel plated with screwdriver stops and caps
Basic upgrade: use 1 ‐ FF16WAC and 1 – FF16LAC manual valves, angleonly, chrome plated with white handles (FF16WAC is adjustable forbalancing, FF16LAC is fixed open but can be closed for service)
TRV (thermostatic radiator valves) are available for automatic temperature control of individualradiators: available in 3 body patterns, with or without thermostatic head (sensor), use in conjunctionwith LKD or FF
TRV remote sensors and adjusters available for special applications
DCK12 – 4” chrome nipple with compression connection available for use with all Myson valves,includes escutcheon (connects valve to heating system)
DAV12 – same as DCK12 with addition of integral ball stop angle valve
Decorative pipe covers and escutcheons available in chrome or white (useto cover exposed copper pipe used in radiator installation)
LKD16AN LKD16SN FF16WAC FF16LAC TRV angle w/HEAD
Remote Sensor Remote Adjuster TRV straight TRV inverted angle TRV HEAD only
DCK DAV
NOTES
Notes
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
15
heatingthroughinnovation.
MYSON Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
DEC
OR
9/20
13