![Page 1: David Garvin Product Manager Mammoth. Agenda Government regulations Carrier replacement Mammoth strategy Long term plan New products](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649eab5503460f94bb0b01/html5/thumbnails/1.jpg)
David GarvinProduct Manager
Mammoth
![Page 2: David Garvin Product Manager Mammoth. Agenda Government regulations Carrier replacement Mammoth strategy Long term plan New products](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649eab5503460f94bb0b01/html5/thumbnails/2.jpg)
Agenda
• Government regulations• Carrier replacement • Mammoth strategy• Long term plan• New products
![Page 3: David Garvin Product Manager Mammoth. Agenda Government regulations Carrier replacement Mammoth strategy Long term plan New products](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649eab5503460f94bb0b01/html5/thumbnails/3.jpg)
Efficiency Changes
• Minimum today
• ASHRAE 90.1-2013 goes into effect as Federal minimum as of January 1, 2018
<5.5 tons 5.5 - 11.25 tons 11.25 - 20 tons ≥20 <63.3 tons
Split/Pack AC 13 11.2 11 10Gas Pack 13 11 10.8 9.8Split/Pack HP 13/ 7.7 11.0/3.3 10.6/3.2 9.5/3.2
Federal Minimum Standards EER / COP
<5.5 tons 5.5 - 11.25 tons 11.25 - 20 tons ≥20 <63.3 tons
Split AC (3 Ph) 13 SEERPack AC 14.0/11.0 11.2 / 12.9 11.0/12.4 10.0/11.6Gas Pack 14.0 11.0 / 12.7 10.8/12.2 9.8/11.4Split/Pack HP 14 / 8.0 11.0/12.2 & 3.3/2.25 10.6/11.6 & 3.2/2.05 10.6/10.6 & 3.2
01/01/2017
ASHRAE 90.1-2013 EER / IEER & COP 47/17
States 01/01/2016, Title 24 1/1/2017, and Fed Min. 1/1/2018
![Page 4: David Garvin Product Manager Mammoth. Agenda Government regulations Carrier replacement Mammoth strategy Long term plan New products](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649eab5503460f94bb0b01/html5/thumbnails/4.jpg)
Efficiency Changes cont.
• Federal minimum as of January 1, 2023
<5.5 tons 5.5 - 11.25 tons 11.25 - 20 tons ≥20 <63.3 tonsProposed Rulemaking on Unitary Large Products, now out to Jan. 2023
Split/Pack AC ? 14.8 IEER 14.2 13.5Gas Pack ? 14.6 14.0 13.3Split/Pack HP 14 / 8.2 14.1/3.5 13.4/3.3 12.5/3.2
Gas Pack 13.4% 10.9% 15.2%
Gas Pack 30% 27% 34%% increase from current to 2023
% increase from current to 90.1-2013
![Page 5: David Garvin Product Manager Mammoth. Agenda Government regulations Carrier replacement Mammoth strategy Long term plan New products](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649eab5503460f94bb0b01/html5/thumbnails/5.jpg)
Efficiency Changes cont.
Commercial Warm Air Furnaces Energy Conservation Standards and their Compliance Dates Gas-fired Commercial Warm Air Furnaces.
– Gas-fired commercial warm air furnaces manufactured on and after January 1, 2023 must have a thermal efficiency at the maximum rated capacity (rated maximum input) not less than 81 percent.
• Oil-fired Commercial Warm Air Furnaces. – Oil-fired commercial warm air furnaces manufactured on and after
January 1, 2023 must have a thermal efficiency at the maximum rated capacity (rated maximum input) not less than 82 percent.
![Page 6: David Garvin Product Manager Mammoth. Agenda Government regulations Carrier replacement Mammoth strategy Long term plan New products](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649eab5503460f94bb0b01/html5/thumbnails/6.jpg)
Big Blue Oval Replacement
• Dakin, Lennox, York, and Rheem and sub brands have direct replacements for older Carrier units. What a great idea.
– Hello….we did that in 2004 with our 12.5 & 15 ton fitting the 48 DP or DR
• Most of these products are at todays minimum efficiency levels• Nortek Global HVAC is currently in the process of matching that
idea and taking this footprint to the next efficiency level• Down and horizontal air flow as shipped• Utilities same location as Carrier• Factory installed options are a mandatory requirement in this
project– Economizers, disconnects, outlets, stainless steel heat exchangers, VFD
blowers, low ambient, hinge panels, BacNet, Lon Communication, smoke detectors,
![Page 7: David Garvin Product Manager Mammoth. Agenda Government regulations Carrier replacement Mammoth strategy Long term plan New products](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649eab5503460f94bb0b01/html5/thumbnails/7.jpg)
Next Steps in Unitary
Tons kW IEER
6 21.114.8 A & B
7.5 26.4 14.856,370 10 35.2 14.8
12.5 44 1415 52.8 14
17.5 61.5 1420 70.3 14
22.5 79.1 13.325 87.9 13.3
3,795 30 105.5 13.335 123.1 13.340 140.7 13.3
Summary
8,825
2,331
Cabinet Szie
Phase 1
AHRI Market Size (Unit)
71,147
37,201
16,161
E
D
DX System Cooling Capacity
B
C
Phase 2
Phase 3
PGE PAC PHP SAC SHP
Phase 4
Phase 5
![Page 8: David Garvin Product Manager Mammoth. Agenda Government regulations Carrier replacement Mammoth strategy Long term plan New products](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649eab5503460f94bb0b01/html5/thumbnails/8.jpg)
Mammoth Next Steps
• Infrared heaters• Tubular radiant heaters• Hydronic and electric unit heaters
![Page 9: David Garvin Product Manager Mammoth. Agenda Government regulations Carrier replacement Mammoth strategy Long term plan New products](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649eab5503460f94bb0b01/html5/thumbnails/9.jpg)
Mammoth 241E
![Page 10: David Garvin Product Manager Mammoth. Agenda Government regulations Carrier replacement Mammoth strategy Long term plan New products](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649eab5503460f94bb0b01/html5/thumbnails/10.jpg)
Thank YouQuestions?