Download - Conference Presentation BioRob2012
![Page 1: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/1.jpg)
Directional vs Non-directional Modes of Vibrotactile Feedback for Arm Posture Replication
Albert Causo, Le Dung Tran, Song Huat Yeo and I-Ming Chen
School of Mechanical and Aerospace Engineering
Nanyang Technological University, Singapore
25th
Jun 2012
1
![Page 2: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/2.jpg)
Motivation & Objective http
:/2.b
p.b
log
spo
t.com
/69
cpY
P6
lmkU
/TV
l_IZ
iRp
zI/AA
AA
AA
AA
Ea
c/
x8y2
JdG
_S
GQ
/s40
0/p
hysio
the
rap
y%2
Bstro
ke%
2B
old
%2
Bw
om
an
.jpg
http:/i1.ytimg.com
/vi/tdFX
lB3H
LUQ
/hqdefault.jpg
15m
67%
stroke patient
survive
Develop low-cost device
for rehabilitation
Best feedback strategy for
posture correction2
![Page 3: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/3.jpg)
Presentation Outline
System Overview
Arm Posture Modeling & Measurement
Vibo-tactile for Posture Correction
3
![Page 4: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/4.jpg)
Different ways of capturing motion
Inertial Motion Unit
MAGNETIC
MECHANICAL
SYSTEM
OPTIC
System Overview Modeling Vibro-tactile
4
![Page 5: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/5.jpg)
Vibro-tactile Feedback
posture guidance
motor learning hand
rehabilitation
5
System Overview Modeling Vibro-tactile
![Page 6: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/6.jpg)
IMU
IMU
Vibro-tactile Unit
System Overview
IMU
Vibro-tactile
Unit
6
System Overview Modeling Vibro-tactile
Software
![Page 7: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/7.jpg)
Arm Posture Modeling
Wrist
Position
Elbow
Position
Forearm
Roll
7
System Overview Modeling Vibro-tactile
![Page 8: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/8.jpg)
Shoulder
Wrist
Elbow
IMU 1
IMU 2
𝐿2
𝐿1
Arm Posture Kinematics
IMU 1 -
𝑟1 ,𝑝1 , 𝑦1
IMU 2 -
𝑟2 ,𝑝2 , 𝑦 2
Arm Lengths -
𝐿1,𝐿2
𝑓 (𝑟 1 ,𝑝1 , 𝑦 1 ,𝑟2 ,𝑝2 , 𝑦 2 ,𝐿1 ,𝐿2)𝑓 (𝑟 2 ,𝑝2 , 𝑦2 ,𝐿2)
wrist -
elbow -
forearm roll -
𝑟1
8
System Overview Modeling Vibro-tactile
![Page 9: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/9.jpg)
Vibro-tactile feedback for arm posture correction
Vibro-tactile unit
Directional feedback
Non-directional feedback
9
System Overview Modeling Vibro-tactile
![Page 10: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/10.jpg)
Directional Feedback Non-directional Feedback
Global
system at
shoulder 10
right hand right hand
System Overview Modeling Vibro-tactile
Local
system at
wrist
![Page 11: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/11.jpg)
Experiments
1 2 3
4 5
11
System Overview Modeling Vibro-tactile
![Page 12: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/12.jpg)
Calibration Step
12
System Overview Modeling Vibro-tactile
![Page 13: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/13.jpg)
Using Vibro-tactile Feedback
Directional Feedback Non-directional Feedback
1m36s 25s13
System Overview Modeling Vibro-tactile
![Page 14: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/14.jpg)
Results
Feedback Strategy Mapping Time (s)Directional Feedback 52.68 ± 17.98
Non-directional Feedback 36.82 ± 19.37
2 3
1 42 3 5
Average error of 7 subjects for 5 posturesAverage error of 7 subjects for 5 postures
14
The use of tactors as directional & non-directional feedback
Error Directional Feedback Non-directional Feedback
Wrist position (mm)
34.42 ± 22.46 26.61 ± 12.92
Elbow position (mm)
20.63 ± 9.53 19.61 ± 9.56
Forearm roll (deg) 6.81 ± 2.96 7.07 ± 3.05
System Overview Modeling Vibro-tactile
![Page 15: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/15.jpg)
Conclusion
IMU
IMU
Vibro-tactile Unit
Integrated System
Arm Posture Modeling
& Measurement
Vibo-tactile for
Posture Correction
15
![Page 16: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/16.jpg)
Future Work
• Combine active visual + audio + vibro-tactile feedback
• Compare direction & non-direction when adding vision
• Design rehab modules
16
![Page 18: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/18.jpg)
APPENDICES
18
![Page 19: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/19.jpg)
Design of GUI
Experiment tabTesting tabConfiguration tab 19
![Page 20: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/20.jpg)
Software - System Overview
StartReceive
Master’s IMU
data
Determine
target
position
Receive
Student’s
IMU data
Determine
current
position
Handle
error
Send tactile
feedbackFinish
Student
adjusts
his/her arm
+-
Arm Replication Process
![Page 21: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/21.jpg)
IMU Measurements
IMU packs 9 sensors (3 accelerometers, 3 angular rate
gyros, 3 magnetometers)
Given the angular value at (t − 1) and t, the numerical approximation becomes
Inertial Motion Unit
![Page 22: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/22.jpg)
Kinematic Formulation (1)
Cartesian transformation
![Page 23: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/23.jpg)
Kinematic Formulation (2)
Yaw - z axis
Pitch - y axis
Roll - x axis
![Page 24: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/24.jpg)
Kinematic Formulation (3)
![Page 25: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/25.jpg)
IMU Specification
![Page 26: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/26.jpg)
Tactor Specification
Specifications of VPM2
VPM2 tactor
Dimensions of VPM2
![Page 27: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/27.jpg)
Capture of Program
![Page 28: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/28.jpg)
IMU device
![Page 29: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/29.jpg)
Vibrotactile Unit
![Page 30: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/30.jpg)
Average error of 7 subjects for 5 posturesAverage error of 7 subjects for 5 postures
Data
Directional and non-directional feedback indicators
Feedback Strategy Mapping Time (s)
Directional feedback 52.68 ± 17.98
Non-directional feedback 36.82 ± 19.37
Average mapping time of 7 subjects for 5 posturesAverage mapping time of 7 subjects for 5 postures
Error Directional feedback Non-directional feedback
Wrist position (mm)
34.42 ± 22.46 26.61 ± 12.92
Elbow position (mm)
20.63 ± 9.53 19.61 ± 9.56
Forearm roll (deg) 6.81 ± 2.96 7.07 ± 3.05
![Page 31: Conference Presentation BioRob2012](https://reader035.vdocuments.us/reader035/viewer/2022062712/563dbb21550346aa9aaa7cc9/html5/thumbnails/31.jpg)
Threshold values
Directional and non-directional experiments