COMPARISON OF PREDICTED SETTLEMENT BEHAVIOUR TO THE
FIELD MEASUREMENT OF STONE COLUMN IMPROVED GROUND
SELVEM S/O RAMAN
UNIVERSITI TEKNOLOGI MALAYSIA
COMPARISON OF PREDICTED SETTLEMENT BEHAVIOUR TO THE
FIELD MEASUREMENT OF STONE COLUMN IMPROVED GROUND
SELVEM S/O RAMAN
A Project Report Submitted as a Partial Fulfillment of The
Requirement For The Award of The Degree of Master of
Engineering (Civil-Geotechnics)
Faculty of Civil Engineering
Universiti Teknologi Malaysia
MAY 2006
iv
Dedicated to my mother and late father
v
ACKNOWLEDGEMENT
I would like to extend my greatest thanks to my mother who is the pillar of my
strength and existence. I would like to present this to my late father whom always would
want me to be someone great. I would like to present my effort to the lotus feet of god
for whom has made myself into who I am now. Special thanks and love goes to the one
whom had discovered the softest side in my heart.
Greatest appreciation goes to Ir. Balakrishnan who has contributed directly and
indirectly in my engineering lifefor moulding me into who I am today. Gratitude also
goes to GCU Geotechnics Sdn. Bhd. and for sponsoring me partly for this course. I
would like to thank my supervisor Associate Professor Dr. Aminaton Marto for her
guidance and for the precious time spent to make this project a success. I would also like
to thank all whom have contributed, be it directly or indirectly for this project report.
Thank you so much.
vi
ABSTRACT
Stone columns form one of the accepted methods of ground improvement at
which large size columns of coarse stones are installed into the ground by means of
special vibrators. It is found that, stone columns increase shear strength of the ground,
thus increasing bearing capacity and stability of the ground as well as to reduce
settlement. The stone column design using Priebe’s method has gained much
widespread use due to its simplicity. However it was found that the settlement
computed using Priebe’s method has always been higher than the field settlement
obtained. A comparison study was carried out between design settlement and field
settlement. Based on the comparison and back analysis it is found that the improvement
ratio of stone column increases with the increase of soil strength. This inherently
implies to that of larger corresponding stone column spacing. Based on the findings,
charts has been made to obtain a settlement reduction factor to be used in calculating
the settlement of the improved ground, resulting in increase in the spacing and reducing
the number of stone columns utilised. The time rate settlement was back calculated
using Asaoka’s method to assess actual coefficient of vertical and horizontal
consolidation. With this, the back calculated spacing together with the coefficient of
consolidation parameters were used to simulate back the field settlement to validify the
findings. Based on the simulation, it was found that the back calculated improvement
ratio and spacing are corresponding well with the actual field settlement. Therefore a
relationship was established for basic soil parameters and the parameters related to
stone column settlement details.
vii
ABSTRAK
Tiang batu adalah salah satu cara pemulihan tanah yang diterima secara umum di
mana batu-batu dimasukkan ke dalam tanah dengan mengunakan pengetar khas. Tidak
dapat dinafikan bahawa tiang batu menambahkan kekuatan ricih tanah dan secara
langsung menigkatkan keupayaan galas dan kestabilan tanah dan juga mengurangkan
enapan. Rekabentuk tiang batu mengunakan kaedah Priebe telah mendapat kegunaan
meluas kerana ia adalah satu kaedah yang mudah untuk digunapakai.
Walaubagaimanapun Secara amnya enapan yang dikira mengunakan kaedah Priebe
selalunya lebih tinggi daripada enapan sebenar di tapak. Satu perbandingan telah
dilakukan diantara magnitud enapan yang dikira menggunakan kaedah Priebe dan
enapan sebenar di tapak. Melalui perbandingan dan pengiraan balik yang dibuat,
didapati bahawa nisbah pembaikan tiang batu meningkat dengan meningkatnya kekuatan
tanah. Ini secara tidak langsung berkait dengan peningkatan jarak antara tiang batu.
Daripada perbandingan dan pegiraan balik, sebuah carta telah di sediakan untuk
mendapatkan faktor pengurangan enapan dimana carta itu boleh digunakan dalam
pengiraan enapan yang secara tak langsung dapat menambahkan jarak antara tiang batu
dan seterusnya mengurangkan bilangan tiang batu yang diperlukan untuk mencapai
enapan yang sama. Kadar enapan juga dikira balik mengunakan kaedah Asaoka untuk
mendapatkan pekali pengukuhan tegak dan ufuk. Dengan mengunakan data pengiraan
balik ini, enapan sebenar di kira balik untuk mengetahui samaada data-data pengiraan
balik itu benar ataupun tidak. Daripada pengiraan balik, telah didapati bahawa, jarak
antara tiang batu dan nisbah pembaikan tiang batu berhubung rapat. Maka satu
hubungan telah dicapai untuk parameter asal tanah dan parameter enapan tiang batu.
viii
TABLE OF CONTENT
CHAPTER TITLE PAGE
DECLARATION 1 ii
DECLARATION 2 iii
DEDICATION iv
ACKNOWLEDGMENT v
ABSTRACT vi
ABSTRAK vii
TABLE OF CONTENT viii
LIST OF TABLES xi
LIST OF FIGURES xii
LIST OF SYMBOLS xiv
LIST OF APPENDICES xvi
1 INTRODUCTION 1
1.1 Introduction 1
1.2 Background of Study 3
1.3 Objectives of Study 4
1.4 Scope of Study 4
2 DESIGN OF STONE COLUMNS 6
2.1 Introduction 6
2.2 Available Design Methods 8
2.3 Priebe’s Method 9
ix
CHAPTER TITLE PAGE
2.4 Consolidation Rate of Stone Column Improved
Ground 16
2 2.5 Findings by others 19
3 STONE COLUMN CONSTRUCTION 20
3.1 Introduction 20
3.2 Vibro Replacement Method (Wet Method) 21
3.3 Vibro-Displacement Method (Dry Method) 22
3.4 Case Borehole Method or Rammed Columns 25
4 RESEARCH METHODOLOGY 27
4.1 Introduction 27
4.2 Phase I : Literature and State of the Practice Review 27
4.3 Phase II : Data Collection 28
4.4 Phase III : Analysis of Data 29
5 SITE FOR CASE STUDY 30
5.1 Introduction 30
5.2 Subsoil Condition 32
6 ANALYSIS AND DESIGN OF STONE COLUMN
GROUND IMPROVEMENT 33
6.1 Introduction 33
6.2 Stone Column Design 34
6.2.1 Input 34
6.2.2 Analysis 43
6.2.3 Output 45
x
CHAPTER TITLE PAGE
6.3 Construction Method Implemented for Reference
Project 45
6.3.1 Stone Column Material 45
6.3.2 Sand for Working Platform and Drainage 46
6.3.3 Installation Method (Wet Top-Feed
Method) 47
6.3.4 Construction Tolerances 48
6.4 Instrumentation 48
7 ANALYSIS AND RESULTS 50
7.1 Introduction 50
7.2 Analysis Design Details 50
7.3 Results of Analysis 51
7.4 Discussion 57
8 CONCLUSION 61
8.1 Conclusion 61
8.2 Recommendation for Further Studies 62
REFERENCES 64
Appendices A-F 67 - 162
xi
LIST OF TABLES
TABLE
NO.
TITLE PAGE
5.1 Location details of stone column improvement work 32
6.1 Estimation of constrained modulus for clays 37
7.1 values to be adopted in the design 51
7.2 Values of , cv and ch adopted in the design 51
7.3 Back analysis summary of Pribe’s Method 53
7.4 Back analysis summary of Han and Ye’s method through
Asaoka’s method 53
7.5 Summary of relationship of stone column fundamental
properties and subsoil properties 57
xi
xii
LIST OF FIGURES
FIGURE
NO.
TITLE PAGE
2.1 Application ranges for vibro techniques 7
2.2 Unit cell concept 8
2.3 Design chart for vibro replacement 11
2.4 Consideration of column compressibility 12
2.5 Determination of depth factor 15
2.6 Determination of depth limit value for depth factor 16
2.7 Typical embankment found on stone columns 18
3.1 Vibro replacement method (wet method) 22
3.2 Vibro replacement method (dry top-feed method) 23
3.3 Vibro replacement method (dry bottom-feed method) 24
3.4 Case borehole method (rammed columns) 26
4.1 Analysis procedure 29
5.1 Project location 31
6.1 Tip resistance and friction ratio CPT soil classification chart 36
6.2 Relative density relationship for moderately compressible,
uncemented, unaged quartz sands 39
6.3 Influence of compressibility on ucemented, unaged,
predominantly quartz sands 40
6.4 Expanded soil behaviour type classification chart with
equivalent overburden normalized friction angle and relative
density trends 41
6.5 Proposed correlation between cone bearing and peak friction
angle for quartz sands 42
6.6 Converting the multi layered subsoil into single layer 44
6.7 Typical instrumentation scheme at stone column improved
ground 49
7.1 Relationship between normalized improvement ratio and
xiii
undrained shear strength 54
7.2 Relationship between normalized spacing and undrained shear
strength 54
7.3 Relationship between normalized settlement reduction factor
and undrained shear strength 55
7.4 Relationship between normalized improvement ratio and
friction angle 55
7.5 Relationship between normalized spacing and friction angle 56
7.6 Relationship between normalized settlement reduction factor
and friction angle 56
xiv
LIST OF SYMBOLS
A Grid area
Ac Stone Column Area
c Cohesion
ch Coefficient of horizontal consolidation
cv Coefficient of vertical consolidation
d Depth of subsoil layer from ground
Dc Constrained modulus of stone column material
Ds Constrained modulus of subsoil
fd Depth factor
H Thickness of subsoil
KaC Coefficient of active earth pr essure of column material
mv Coefficient of volume change
n Settlement improvement ratio
Nk Cone factor
Pc Pressure within stone column along the depth
Ps Pressure within soil in tributary area
qc Cone friction
R Settlement reduction factor
Su Undrained shear strength
Ur Degree of consolidation (radial only)
Urv Degree of consolidation (both radial and vertical)
Uv Degree of consolidation (vertical only)
Coefficient of constrained modulus
ig Settlement of improved ground
og Settlement of unimproved ground
c Friction angle of stone column material
s Friction angle of subsoil
xv
s Bulk density of subsoil
s Poisson’s ratio of stone column material
vo Insitu overburden stress
xvi
LIST OF APPENDICES
APPENDIX TITLE PAGE
A Analysis Summary 67
B Analysis for CH254890 to CH255095 77
C Analysis for CH261950 to CH263125 95
D Analysis for CH272100 to CH272350 113
E Analysis for CH297250 to CH 288250 130
F Analysis for CH299400 to CH299625 146
CHAPTER 1
INTRODUCTION
1.1 Introduction
In quest of knowledge and demand, there is ever increasing awareness of new
technologies created or found by man. The field of geotechnical engineering is not
new to this phenomenon. Over the last century, the field of geotechnical engineering
has achieved many milestones with brilliant ideas and advancements. The ground
improvement techniques is one of the area which has attained lots of interest and
improvements due to an interesting fact that ‘anything can be constructed anywhere
if only proper foundation is laid’.
Many methods for ground modification and improvement are available
around the world now, including dewatering, compaction, preloading with and
without vertical drains, grouting, deep mixing, deep densification and soil
reinforcement are among those. Many of these techniques, such as dewatering,
compaction, preloading and grouting, have been used for many years. However,
there have been rapid advances in the areas of deep densification (vibro-compaction,
deep dynamic compaction, compaction piles, and explosive densification), jet and
compaction grouting, deep mixing, and vibro-replacement and vibro-displacement in
2
recent years. These methods have become practical and economical alternatives for
many ground improvement applications.
While most of these technologies were originally developed for uses other
than seismic risk mitigation, many of the recent advances in the areas of deep
densification, jet and compaction grouting, and deep mixing methods have been
spurred on by the need for practical and cost effective means for mitigating seismic
risks. Many of these methods have also been applied to increase the liquefaction
resistance of loose, saturated, cohesionless soils.
Ground improvement techniques basically utilize the effects of increasing
adhesion between soil particles, densification and reinforcement to attain on or more
of the following:
(1) increased strength to improve stability,
(2) reduced deformation due to distortion or compressibility of the soil mass,
(3) reduced susceptibility to liquefaction, and
(4) reduced natural variability of soils.
Of many techniques of ground improvements, stone column has gained lots
of popularity since it has been properly documented in the middle of the last century.
As in most new ground improvement techniques that were developed in foreign
countries, experience has preceded the development of theory and comprehensive
guidelines. Potential applications of stone column include the following :
(1) stabilizing foundation soils,
(2) supporting structures,
(3) landslide stabilization, and
(4) reducing liquefaction potential of clean sands.
The high potential for beneficial use of stone columns is mainly as a ground
improvement technique to strengthen weak and soft soil. This includes the area of
highway, railway and also airfield applications prompted a comprehensive
investigation to determine how and why the system works so well, and to develop
3
appropriate design and construction guidelines. This has resulted in many empirical
design concepts to be published for the purpose of designing the stone column.
1.2 Background of Study
Vibro replacement or stone column has been adapted and utilized as one of
the effective ground improvement method since early 1980’s. This can be referred
back to the ground improvement carried out at certain parts of North South
Expressway, Keretapi Tanah Melayu (KTM) double tracking between Seremban and
Rawang and many more locations throughout the country.
The stone column technology is not new as far as Malaysia is concern, simply
because of the history and the number of contractors engaged in this business. The
major players who were also pioneers in stone column construction in Malaysia are
Keller (M) Sdn. Bhd. and Bauer (M) Sdn. Bhd. There are many other local stone
column contractors now in the market besides these two foreign companies.
Even though the design of stone column is broadly based on empirical
methods, there are a lot of studies being carried out to date to improvise the design
and detailing of the stone columns to match the following details:
(1) local subsoil condition and
(2) local construction methodology.
Most of the cases, there are instrumentations carried out at those areas
improved by stone column but those data have never been utilized fully for the
purpose of improvising the design methodologies adopted. Thus it is appalling that
we, Malaysians have to rely heavily on the foreign research and approach to solve
our own problems.
4
Therefore, an attempt is being made to understand the major principle behind
the stone column ground improvement which is to reduce the total settlement, in
local geotechnical context.
The design works has been carried out based on certain subsoil parameters
derived from the soil investigation carried out at site. This design has been carried
out based on one of the empirical methods available. While the method is predicted
to provide relatively good assessment of the details needed, there is much to be done
to improvise the design approach by comparing the results with the field
instrumentation results. By doing so, it is assumed, at this stage that there could be
some improvement in the context of the detailing such as spacing and number of
stone columns.
1.3 Objectives of Study
The main objectives of the study are as follows:
(1) to predict the settlement behaviour of stone column improved ground
using Priebe’s Method (Priebe H. J., 1995),
(2) to compare the predicted settlement with the field settlement.
(3) to suggest improvisation in the design method adopted based on results
obtained in the comparison study.
1.4 Scope of Study
This study is confined to the following scopes:
(1) This study is to focus on the writer’s own design work carried out using
Priebe’s Method (Priebe H. J., 1995) only.
5
(2) The construction of stone column was carried out based on top feed vibro
replacement method (wet method).
(3) The data collected for the areas or locations of stone column ground
improvement in Malaysia only.
(4) The minimum number of data set is limited to 5 numbers.
(5) The study focuses only on the settlement behaviour of the stone columns.
64
REFERENCES
Abhijit S. and De P. K. (1996) The Stress Concentration Ratio in Soil – Stone Column
Interaction. Twelft South East Asian Geotechnical Conference, Kuala Lumpur.
Aboshi, H. and Suematsu, N. (1985) The State of the Art on Sand Compaction Pile
Method. Geotechnical Seminar on Soil Improvement Methods. Nanyang
Technological Institute, Singapore.
Barksdale R. D. and Bachus R. C. (1983) Design and Construction of Stone Columns.
Volume 1, Federal Highway Administration, United States Department of
Transportation.
Bergado D. T., Alfaro M. C. and Chai J. C. (1991) The Granular Pile : Its Present State
and Future Prospects for Improvement of Soft Bangkok Clay. Geotechnical
Engineering Journal. Asian Institute of Technology, Bangkok.
Greenwood D. A. and Kirsch K. (1983) Specialist Ground Treatment by Vibratory and
Dynamic Methods. Thomas Telford. London.
Goughnour R. R. and Bayuk A. A. (1979) A Field Study of Long-Term Settlement of
Loads Supported by Stone Colums in Soft ground. International Conference on Soil
Reinforcement : Reinforcement Earth and Other Techniques, Vol. 1, Paris.
65
Jean-Louis Briaud and Jerome Miran (1991) The Cone Penetration Test. The Federal
Highway Administration, Washington D. C.
Jie Han and Shu-Lin Ye (2001) Simplified Method for Consolidation Rate of Stone
Column Reinforced Foundations. Journal of Geotechnical and Geoenvironmental
Engineering, ASCE.
Mohd. Marzuki Bin Mohamed, (1994) Application of Stone Column in Karstic
Formation. IKRAM Seminar on Engineering in Karstic Formation.
Madhira R. Madhav and Nagpure D. D. (1996) Design of Granular Piles for
Embankments on Soft Ground. Twelft South East Asian Geotechnical Conference,
Kuala Lumpur.
Nayak N. V. (1982) Recent Innovations in Ground Improvement by Stone Columns.
Symposium on Recent Developments in Ground Improvement Techniques,
Bangkok.
Poorooshasb H. B. and Meyerhof G. G. (1993) Consolidation Settlement of Rafts
Supported by Stone Columns. Ground Engineering Journal.
Priebe H. J. (1993) Design Criteria for Ground Improvement by Stone Columns. Fourth
National Conference, Ground Improvement, Lahore, Pakistan.
Priebe H. J. (1995) The Design of Vibro Replacement. Ground Engineering Journal.
Priebe H. J. (1998) Vibro Replacement to Prevent Earthquake Induced Liquifaction.
Geotechnique-Colloquium, Darmstadt, Germany.
66
Raju V. R. and Hoffman G. (1996) Treatment of Tin Mine Tailings Deposits in Kuala
Lumpur Using Vibro Replacement. Twelft South East Asian Geotechnical
Conference, Kuala Lumpur.
Raju V. R. (1997) The Behaviour of Very Soft Soils Improved by Vibro Replacement.
Ground Improvement Conference, London.
Raju V. R., Wegner R. and Hari Krishna Y. (2004) Ground Improvement Using Vibro
Replacement in Asia 1994 to 2004 – A 10 Year Review. Keller Foundozani,
Germany.
Rao S. N., Reddy K. M., and Kumar P. H. (1995) Studies of Stone Columns in Soft
Clays. Ground Engineering.
Robertson P. K. and Campanella R. G. (1983) Interpretation of Cone Penetration Test.
Canadian Geotechnical Engineering Journal, Vol. 20, Canada.
Sanglerat G. (1972) The Penetrometer and Soil Exploration. Elsevier Publishing
Company, Amsterdam.
Vesic A. S. (1970) Tests on Uninstrumented Piles, Ogeechee River Site. American
Society of Civil Engineers, United States of America.