Transcript
Page 1: CM8-F126/32/42 Catalog Number: - Amazon Web Servicessignify-documents.s3-eu-west-1.amazonaws.com/.../CO2-12.pdf · 2019. 12. 13. · 8" HORIZONTAL TRIMS PHOTOMETRICS Capri Lighting

10 1/4"(260 mm)

17 3/16"(436 mm)

15"(381 mm)

7 3/4"(197 mm)

6 3/4"(172 mm)

6 1/2"(165 mm)

7"(178 mm)

7/8"(22 mm)

5 1/2"(140 mm)

IntegralOption1

RemoteOption

CM813 1/8"33 mm)

10 1/4"(260 mm)

14 7/8"(378 mm)

7"(178 mm)

9 3/4"(248 mm)

8 3/4"(222 mm)

8 7/16"(214 mm)

7/8"(22 mm)

12 19/32"(320 mm)

9 13/32"(239 mm)

6 5/8"(168 mm)

9"(229 mm)

7 1/16"(179 mm)

2 1/2"(64 mm)

6 15/32"(164 mm)

CM8R CM8S

INTEGRAL &REMOTE ER

17 1/2"(445 mm)

17 3/4"(451 mm)

16 1/2"(419 mm)

21 9/32"(541 mm)

12 17/32"(417 mm)

4 3/4"(121 mm) 7/8"

(22 mm)

CATALOG SYSTEM AND OPTIONS

Plaster Frame

_________CM8 8" Standard FrameCM8R8" Remodel FrameCM8S8" Slope Frame7

Electrical System

__________

F126/32/42(1)CFQ26W/G24q(1)CFM26W/GX24q(1)CFM32W/GX24q(1)CFM42W/GX24q

Ballast Options

_________

U 120V-277VS3 347V

Options

_________

RI Radio Filter

FS2 Fusing2

ER Remote Emergency Ballast4

E Integral Emergency5

Trims (choose one)6

___________H83 Gold ReflectorH83E Gold Reflector, EmergencyH83SL Gold Reflector, Self LippedH85 Low Iridescent ReflectorH85E Low Iridescent Reflector, EmergencyH85SL Low Iridescent Reflector, Self LippedH86 White ReflectorH86E White Reflector, EmergencyH86SL White Reflector, Self LippedH87 Wheat ReflectorH87E Wheat Reflector, EmergencyH87SL Wheat Reflectors, Self LippedH85BC Black Baffle, Clear Lens Insert3

H85BF Black Baffle, Fresnel Lens Insert3

H85BP Black Baffle, C73 Prismatic Lens3

H85B Low Iridescent Reflector, Black Baffle

H85BE Low Irid.Refl., Black Baffle, Emer.H85WB Low Iridescent Refl., White BaffleH85WBE Low Irid. Refl., White Baffle, Refl.H85WBC White Baffle, Clear Lens Insert3

H85WBF White Baffle, Fresnel Lens Insert3

H85WBP White Baffle, C73 Prismatic Lens3

HW83 Gold Reflector, Single Wall WashHWD83 Gold Reflector, Double Wall WashHW85 Low Irides. Refl., Single Wall WashHWD85 Low Irides. Refl., Double Wall WashHW87 Wheat Reflector, Single Wall WashHWD87 Wheat Reflector, Double Wall WashH85C Clear Cone, Clear Lens Insert3

H85F Clear Cone, Fresnel Lens Insert3

H85P Clear Cone, C73 Prismatic Lens3

H86C White Splay, Clear Lens Insert3

H86F White Splay, Fresnel Lens Insert3

H86P White Splay, C73 Prismatic Lens3

H85XB Low Irides. Refl., Cross BaffleH85SWR Shower Trim3, 9

H85SR10 5°- 15° Slope8

H85SR20 16°- 25° Slope8

H85SR30 26°- 35 Slope8

CM8-F126/32/428" Horizontal Compact Fluorescent26, 32 and 42 watt

-

Plaster Frame

_________CM8 8" Standard FrameCM8R8" Remodel FrameCM8S8" Slope Frame7

Electrical System

__________F126(1)CFQ26W/G24q(1)CFM26W/GX24qF1321)CFM32W/GX24qF1421)CFM42W/GX24q

Ballast Options

_________DX1 dimming 120VDX2 dimming 277V

-

-

REV. 11/07

Catalog Number:____________________________

Type:_______________________________________

Project:_____________________________________

DescriptionEight inch horizontal downlight rated for use with two 26, 32 or 42 watt lamps. Wide variety of trims available. Optional emergency provides a self contained emergency battery which operates one lamp for a minimum of 90 minutes following a power failure.

Features• Adjustable socket cup.• Easy, snap fit installation.• Many wet location trim options.• Standard electronic ballast with <10% THD.• c/UL listed for damp locations and through branch circuit wiring.

FRAME1. Frame - 22 gauge die stamped metal frame with flangededges to provide a smooth handling surface. CM8 frame canbe easily converted in the field to 4'' and 6'' aperture sizeswith optional interchangeable aperture rings. Frames can beinstalled before lamp source or wattage has been determined.Suitable for installation in environmental air-handling ceilings.2. Mounting- Adjustable spring steel butterfly brackets accom-modate CH24 or CH48 channel bar hangers, BH3 flat barhangers, or 1/2" EMT conduit. L-brackets slide into place onany of the four corners to secure emergency option to theframe. Emergency tray rests on bar hangers or EMT for sup-port. Frame can be supported with aircraft cable whererequired.

ELECTRICAL SYSTEM1. Ballast - All ballasts are electronic High Power Factor andare attached directly to the junction box door at the factory.Available with optional dimming ballast for energy efficiency.Pre-installed quick connectors.2. Socket Cup - The socket cup attaches directly to the trimwithout the need for tools. All socket cups orient the lamp at

optical focal plane of reflector for precise optics and optimumperformance. Socket is adjustable.3. Junction Box - Plaster frame integrated 47 cubic inch junc-tion box with four 1/2" and two 1" knockouts. Electrical con-nections are made through a single junction box door, whichallows all electrical systems to snap into place on the frame.4. c/UL Listed - Approved for through branch wiring with upto 8 #12 AWG conductors.5. Remote Emergency Module - A special high temperaturenickel cadmium battery charger, and electronic circuitry con-tained in a compact case. Test switch and charging indicatorare mounted outside the reflector. Emergency illuminationexceeds NEC, NFPA-LSC and UL 90-minute req.6. Integral Emergency Module -A special high temperaturenickel cadmium battery charger, and electronic circuitry con-tained in a compact case. Test switch and charging indicatorare mounted inside the reflector. For use with emergencytrims only. Emergency illumination exceeds NEC, NFPA-LSCand UL 90-minute req.

TRIMS1. Reflector - Precision spun low iridescent .050 aluminum.Separate injection molded, white polycarbonate trim ring.

2. Baffle - Precision spun .040 aluminum with deep grooves toreduce aperture glare. Non-reflective matte black or whitepainted finishes.3. Installation - Capri One trims attach directly to the framevia expandable torsion springs. When used in conjunction withthe molded spring tabs on the plaster frame, the torsion springsallow for full rotation and adjustment from below the fixture.4. c/UL Listed - All emergency units are dry location only.

OPTIONS Dimming Ballast - Dependent upon lamp configuration.Fuse - Fuse kit field installation. (FS2)Radio interference filter. (RI)Emergency option - Integral or Remote options available.Note: Integral must be used with emergency trim.

ACCESSORIES (Order separately)27" Flat Bar Hangers . . . . . . . . . . . . . . . . . .BH326" C-Channel Bar Hangers . . . . . . . . . . . .CH2450" C-Channel Bar Hangers . . . . . . . . . . . .CH48Emergency Remote Field installable Kit . . . . .ERFK

CO2-12

DIMENSIONS

UNIVERSAL

DIMMING

SAMPLE CATALOG NUMBER: CM8-F226U-H85

Footnotes:2. Field Installable.3. UL Listed Wet location.4. ER option is available with dry location trims only.5. For use with Emergency trims only.6. Reflector must have “E” suffix for integral emergency option.7. For use with H85SR10, H85SR20 and H85SR30 slope trims only.8. For use with CM8S Slope Frame only. Not for use with ER options.9. Not for use with emergency option.

General Notes:DX1 and DX2 are standard Advance Mark X dimming. Optional DL1 and DL2 for Lutron Compact SE dimming available.

Page 2: CM8-F126/32/42 Catalog Number: - Amazon Web Servicessignify-documents.s3-eu-west-1.amazonaws.com/.../CO2-12.pdf · 2019. 12. 13. · 8" HORIZONTAL TRIMS PHOTOMETRICS Capri Lighting

8" HORIZONTAL TRIMS

PHOTOMETRICS

Capri Lighting reserves the right to make changes without notice.©2007

CAPRI LIGHTING:776 South Green St., Tupelo, MS 38804Phone 662.842.7212 FAX 662.841.5501www.caprilighting.com

CO2-12THOMAS LIGHTING CANADA:189 Bullock Drive, Markham, Ontario, Canada L3P 1W4Phone 905.294.9570 FAX 800.268.0003www.thomaslightingcanada.com

CM8-F226-H85Description: 8” Compact Fluorescent - 2 Lamp Horizontal Downlight, Clear Reflector

5° 15° 25° 35°

45°

55°

65°

75°

85°

0° (Parallel)90° (Normal)

200

400

600

800

1000

1200

1400

1600

Candlepower Curve

Coefficients of Utilization

Ceiling Cavity Reflectance80 50 10

Wall ReflectanceRoom 50 30 10 50 30 10 50 30 10

Cavity Ratio CU for Floor Cavity Reflectance = 20%0 70 70 70 65 65 65 60 60 601 64 63 61 61 60 58 57 56 552 59 57 55 56 54 53 53 52 513 55 51 49 52 50 48 49 48 464 50 46 44 48 45 43 46 44 425 46 42 39 44 41 39 42 40 386 42 38 35 41 37 35 39 36 347 39 34 32 37 34 31 36 33 318 35 31 28 34 30 28 33 30 279 32 27 25 31 27 24 29 26 24

10 29 25 22 20 24 22 27 2422

These coefficients were computed by the zonal-cavity method, I.E.S. rec-ommended practice, and prepared from the candlepower distributiondata in photometric report 2176

Conversion Factors

For average foot candle calculations.Multiply footcandles by conversion factor.

Trim ConversionCatalog # FactorH83 .90H84 .75H86 .88H87 .87

5° 15° 25° 35°

45°

55°

65°

75°

85°

0° (Parallel)90° (Normal)

200

400

600

800

1000

1200

1400

1600

Candlepower Curve Candlepower SummaryZone Degree 0° Candelas 90° Candelas

90..............................0.......................085...............................0 ........................080...............................0 ........................075...............................0 ........................070...............................1 ........................265...............................2 ........................360...............................8 ........................855.............................131....................14050.............................353....................46645.............................658....................83740............................1000..................118135............................1191..................137030............................1243..................150525............................1281..................161520............................1355..................173115............................1376..................177410............................1366..................16965.............................1359..................16060.............................1464..................1464

Coefficients of UtilizationCeiling Cavity Reflectance

80 50 10Wall Reflectance

Room 50 30 10 50 30 10 50 30 10Cavity Ratio CU for Floor Cavity Reflectance = 20%0 68 68 68 64 64 64 58 58 58

1 63 61 60 59 58 57 55 55 542 58 55 53 55 53 52 52 51 493 53 50 48 51 48 46 48 46 454 49 45 43 47 44 42 45 43 415 45 41 38 43 40 37 41 39 376 41 37 34 40 36 34 38 35 337 37 33 31 36 33 30 35 32 308 34 30 27 33 29 27 32 29 269 31 26 24 30 26 23 28 25 23

10 28 24 21 27 23 21 26 23 21

These coefficients were computed by the zonal-cavity method, I.E.S. recom-mended practice, and prepared from the candlepower distribution data inphotometric test no. 2179

Candlepower SummaryZone Degree 0° Candelas 90° Candelas90 0.............................0.........................

85............................0........................180............................0........................175............................0........................170............................0........................165............................1........................260............................4........................555...........................89......................9950..........................273....................36945..........................517....................68240..........................716....................91535..........................785...................102830..........................798...................111725..........................858...................120520..........................945...................128815..........................981...................127410..........................969...................11495...........................931...................10730...........................924....................924

For average foot candle calculations.Multiply footcandles by conversion factor.

Trim ConversionCatalog # FactorH83 .90H84 .75H86 .88H87 .87

CM8-F242-H85BDescription: 8” Compact Fluorescent - 2 LampHorizontal Downlight, Clear Reflector

Lamp: (2) CFQ26W/G24qIES Spacing Criteria: Nor - 1.6,Par - 1.3

Beam Angle: 102°Efficiency: 57.7%%

Lamp: (2) CFM42W/GX24qIES Spacing Criteria: Nor - 1.4,Par - 1.3

Beam Angle: 98°Efficiency: 59.0

Conversion Factors

H85 Clear ReflectorH85E Clear Reflector, EmergencyH85SL Clear Reflector, Self-Flanged**

H83 Gold ReflectorH83E Gold Reflector, EmergencyH83SL Gold Reflector, Self-Flanged**

H84 Black ReflectorH84E Black Reflector, EmergencyH84SL Black Reflector, Self-Flanged**

H86 White ReflectorH86E White Reflector, EmergencyH86SL White Reflector, Self-Flanged**

H87 Wheat ReflectorH87E Wheat Reflector, EmergencyH87SL Wheat Reflector, Self-Flanged**

Black Baffle, Glass Lens Insert

H85BC Clear Lens*H85BF Fresnel Lens*H85BP C73 Prismatic Lens*

H85B Clear Reflector, Black BaffleH85BE Clear Reflector, Black Baffle,

Emergency

H85WB Clear Reflector, White BaffleH85WBE Clear Reflector, White Baffle,

Emergency

White Baffle, Glass Lens Insert

H85WBC Clear Lens*H85WBF Fresnel Lens*H85WBP C73 Prismatic Lens*

White Splay, Glass Lens Insert

H86C Clear Lens*H86F Fresnel Lens*H86P C73 Prismatic Lens*

HW85 Clear Reflector, Single Wall Wash

HWD85 Clear Reflector, Double Wall Wash

H85XB Low IridescentCross Baffle Reflector

HW83 Gold Reflector, Single Wall Wash

HWD83 Gold Reflector, Double Wall Wash

H85SWR Shower Trim*Not available with Emergency Option

Clear Cone, Glass Lens Insert

H85C Clear Lens* H85F Fresnel Lens*H85P C73 Prismatic Lens*

Clear Reflector, White Dome Ceiling cutout: 12" diameter

H85SR10 Accommodates 5˚-15˚ SlopeH85SR20 Accommodates 16˚-25˚ SlopeH85SR30Accommodates 26 -̊35˚ Slope

Use with CM8S housing only.Not available with Emergency option.

*UL Listed for wet location. **Self-Flanged has same finish as reflector.