Transcript
Page 1: Chemtrols-India-AMETEK Drexelbrook-USA make,RF Point Level Switches

DREXELBROOKDREXELBROOK®

A Leader In Level Measurement Solutions

The Point™ RF Series Point Level Switch

Intelligent Electronics Save Time and Money• UNIQUE!-NOcalibrationorsetpoint adjustments,formostapplications.• UNIQUE!-Ignoreschangesindielectricor conductivity.• Automaticallyrecognizesandignorescoatings topreventfalsealarms.• Universalpowersupplyautomatically detects&adjuststoinputpowersource.

Diverse Applications• Detectstheabsenceorpresenceofliquids, slurries,andgranulars.• Capableofhighpressuresandtemperatures.

Economical Without Sacrifice• Retainssuperiorperformance.• Lessmaintenancethanothertechnologies; nomovingpartstohanguporwearout.

Output • DPDTrelaydrycontactsat5A,120VAC.

Remote or Integral Electronics• Unlikemanytechnologies,electronicscanberemotemountedtoaconvenientorsafelocation

One of the Drexelbrook RF Point Level Switches You Won't Have to Calibrate

Simply install ThePoint Series into the tankand apply power…that's it! Unlike other RF orcapacitance systems that require calibrationvia setpoint potentiometers, jumpers, magnets,or pushbuttons, ThePoint Series reliably detectstheabsenceorpresenceofmaterialwithoutanyadjustments.

ThePointSeriessoftwarecontinuouslymonitorstheapplicationforchangesincomposition,dielectricor conductivity, and maintains a repeatable trippoint on the probe. Other RF and capacitancesystemsrequirecalibrationadjustmentswhentheprocessmaterialischanged.SinceThePointSeriesrecognizeschangesinmaterial,itisidealfornon-dedicatedtanksthatareusedforawidevarietyofproducts.

Lower Cost of Ownership Inadditiontolowerinitialinvestment,ThePointcontinues to save with little or no maintenancecompared with other technologies. Further, thesensorcanbelengthenedorshortenedinthefield,savingneedforadditionalpurchases.

Universal Power SupplyThePointelectronicsuseauniversalpowersupplymodulethatcanbepoweredfroma19to250Vacor18to200Vdcsupplywithoutmovingjumpers.

joseph
Chemtrols Industries Ltd. Emblem
Page 2: Chemtrols-India-AMETEK Drexelbrook-USA make,RF Point Level Switches

Technology: RFAdmittance.Calibration: None(formostapplications).Modes Of Operation:HighandLowLevel.Repeatability:2mm(0.08inch)conductiveliquids.Response Time:Lessthanonesecond.Ambient Electronic Temperature:-40to70°C(-40to158°F)FM,CSAStorage Temperature:-40to85°C(-40to185°F).Indicators:LEDs:GreenPower,RedRelay1.Time Delay:0-60seconds,forwardorreverse-acting.Supply Voltage:19-250VAC18-200VDCAuto-detectingwithoutjumpers.Power Consumption:2wattsmaximum.Relay Contacts: DPDTdrycontactsat5A,120Vac.Maximum Contact Load: 5A/30VDC5A/250VACMaximum Switching Capacity: 2000VA/150Watt.Minimum Contact Load (DC):100mA/12VDC0-200mA/12VDC(Optional)Housing:Powder-Coatedaluminumwithtwocableentries.Cable Entry:M20x1.5¾-inchNPT

Ingress Protection:IP66NEMA4XApprovals:

Remote Explosion-proofforClassI,Division1,GroupsA,B,C,andD;Dust-Ignition

proofforClassII,III,Division1,GroupsE,F,andG;Non-incendiaryforClassI,Division2,GroupsA,B,C,&D;SuitableforClassII,III,Division2,GroupsF&GhazardousoutdoorType4,4X,IP66(classified)locationswithIntrinsicallySafeconnectionstoClassI,II,III,Division1,GroupsA,B,C,D,E,F,andGhazardous(classified)locationsinaccordancewithControlDrawing420-0004-181-CD.Integral:[Same,butGroupAdoesnotapply.]

Integral SensorsClassI,GroupsB,C,D;ClassII,GroupsE,F,G;ClassIII;Type4,4X,IP66;T5forTa=70°C.

ClassI,Division2,GroupsA,B,C,D;ClassII,Division2,GroupsF,G;ClassIII;Type4,4X,IP66;T5forTa=70°C

Remote SensorsClassI,GroupsA,B,C,D;ClassII,GroupsE,F,G;ClassIII;Type4,4X,IP66;T5forTa=70°CClassI,Division2,GroupsA,B,C,D;ClassII,Division2,GroupsF,G;ClassIII;Type4,4X,IP66;T5forTa=70°C

The Point™Specifications

19 to 253 Vac19 to 55 VdcAuto-Detecting Without Jumpers

4.5"(114mm)

6.5"(165mm)

4.75"(121mm)

DimensionsWiring

Test Safe (ForRemoteElectronics)

Electronics Exd[ia]IICT5DIPA21 Ta=100˚C

SensingElement ExiaIICT6

0344

II 1/2 G EEx d[ia] IIC T2..T5, Ta = -30°C to +70°CII 1/2 D T 90°C

joseph
Chemtrols Industries Ltd. Emblem
Page 3: Chemtrols-India-AMETEK Drexelbrook-USA make,RF Point Level Switches

Sensing Element Application Sensing Element Pressure/Temperature Wetted Parts00 General purpose 700-1202-001 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK 700-1202-021 integral01 Floating roof with 700-1202-012 remote 13.8 bar @ 177°C (200 PSI @ 350°F) 316SS, Brass, cable attachment 700-1202-022 integral and PEEK and brass bottom weight02 General purpose, 700-1202-014 remote 13.8 bar @ 177°C (200 PSI @ 350°F) 316SS and PEEK longer insertion lengths 700-1202-024 integral with cable attachment and 316SS bottom weight03 Proximity 700-1202-018 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK 700-1202-028 integral with 76 mm (3) 316SS proximity plate04 General purpose, 700-1202-041 remote 69 bar @ 121°C (1000 PSI @ 250°F) 316SS and PEEK high temperature 700-1202-042 integral 20.7 bar @ 232°C (300 PSI @ 450°F) and pressure06 General purpose with 700-1202-031 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and FDA grade FDA approved 700-1202-032 integral PEEK materials of construction07 General purpose 700-1202-010 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK with Granular materials 700-1202-020 integral 7/8 inch dia. 316SS collar09 General purpose 700-1202-033 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and FDA grade Granular materials with 700-1202-034 integral PEEK with 7/8 inch dia. FDA approved 316SS collar materials of construction10 Corrosive liquids (2)(4)(9) 700-0001-018 remote 3.4 bar @ 149°C (50 PSI @ 300°F) PFA11 General purpose, 700-0201-005 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE higher pressure 13.8 bar @ 232°C (200 PSI @ 450°F) TFE compatibility required12 Corrosive material, 700-0201-005 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) Hastelloy C and TFE higher pressure Hastelloy C 13.8 bar @ 232°C (200 PSI @ 450°F)13 Sanitary (3) 700-0201-036 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316/316L SS and TFE 13.8 bar @ 232°C (200 PSI @ 300°F)14 General Purpose, 700-0202-002 int/rem 3.4 bar @ 149°C (50 PSI @ 300°F) 316SS and TFE low pressure 1.4 bar @ 232°C (20 PSI @ 450°F)15 Heavy duty, agitated 700-0202-043 remote 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE tanks or material 13.8 bar @ 232°C (200 PSI @ 450°F) with high bulk density (1) 16 High Integrity Seal for 700-0002-360 int/rem 34.5 bar @ 149°C (500 PSI @ 300°F) PFA Hazardous Materials17 Sanitary (3) lowpressure 700-0202-036 int/rem 3.4 bar @ 149°C (50 PSI @ 300°F) 316SS and TFE18 Corrosive material, 700-0001-022 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) TFE higher pressure with 34.5 bar @ 149°C (500 PSI @ 300°F) waterlike viscosity (4)19 Interface Measurement 700-0002-023 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE 34.5 bar @ 149°C (500 PSI @ 300°F) 20 Miniature Pilot 700-0209-002 remote 6.9 bar @ 121°C (100 PSI @ 250°F) 316 SS and TFE Plant Sensor (1)(7) 0 bar @ 232°C (0 PSI @ 450°F)Fly Ash Precipitators, Baghouse, and Economizers (1) (6) Application Sensing Element Pressure/Temperature Wetted Parts31 No hopper Installation 700-0029-001 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE 32 Hopper Installation 700-0029-002 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 200mm (8 inches) 33 Hopper Installation 700-0029-003 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 406mm (16 inches) 34 Hopper Instalation 700-0029-004 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 521mm (20.5 inches) 35 Hopper Installation 700-0029-005 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 635mm (25 inches) Plugged Chute Detection (1) (5) Application Sensing Element Pressure/Temperature Wetted Parts50 Flush Mount Sensor 700-0207-001 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and 305mm2 (12 inches2) Polyurethane heavy duty51 Flush Mount Sensor 700-0207-002 remote 0.1 bar @ 149°C (1 PSI @ 300°F) 304 SS and TFE 305mm2 (12 inches2) higher temperature52 Flush Mount Sensor 700-0207-003 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and Neoprene 305mm2 (12 inches2) with curved radius 153, 229, 305 mm (6, 9, or 12 inches)53 Flush Mount Sensor 700-0207-004 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 410 SS and UHMW 305mm2 (12 inches2) Polyethylene extra heavy duty55 Flush Mount Sensor 700-0207-006 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and 203mm2 (8 inches2) Polyurethane heavy dutyHigh Pressure / High Temperature60 High Pressure & Temp. 700-0204-038 remote 137.9 bar @ 93°C (2000 PSI @ 200°F) 316SS and Ceramic 68.9 bar @ 260°C (1000 PSI @ 500°F)61 High Temperature 700-0204-002 remote 0 bar @ 816°C (0 PSI @ 1500°F) 316SS and Ceramic62 High Pressure & Temp. 700-0204-048 remote 275.8 bar @316°C (4000 PSI @ 600°F) 316SSZZ Sensing Element Not Listed

Output1 One DPDT Relay, dry contacts, 5A, 120VAC (Min 100 mA / 12 VDC) 2 One DPDT Relay, gold plated contacts (Max 200 mA / 12 VDC)

Housing

TechnologyP RF Admittance

InputL Universal Power Supply 19-250 VAC, 18-200 VDC

Measurement TypeL No Calibration, 2 pF Fixed PreloadP No Calibration, 0.5 pF Fixed Preload (High Sensitivity)M Manual CalibrationG Manual Calibration (High Sensitivity)

Electronics0 Integral1 Remote, no cable2 Rmt. w/ 3 m (10 ft.) G.P. cable3 Rmt. w/ 7.6 m (25 ft.) G.P. cable4 Rmt. w/ 10.6 m (35 ft.) G.P. cable5 Rmt. w/ 15.2 m (50 ft.) G.P. cable6 Rmt. w/ 23 m (75 ft.) G.P. cable

IL CSLxxxG 457 mm (18") 0 mm (0")xxxH 914 mm (36") 254 mm (10")xxxJ 914 mm (36") 0 mm (0")xxxK 1219 mm (48") 254 mm (10")xxxL 1524 mm (60") 254 mm (10")P00X IL/CSL OtherA1BX IL/CSL factory set for Fly AshxxxZ Other

IL CSLxxx1 457 mm (18") 152 mm (6")xxx2 305 mm (12") 152 mm (6")xxxA 152 mm (6") 51 mm (2")xxxB 305 mm (12") 51 mm (2")xxxC 305 mm (12") 89 mm (3.5")xxxD 457 mm (18") 51 mm (2")xxxE 457 mm (18") 89 mm (3.5")xxxF 457 mm (18") 254 mm (10")

Mounting Type (See separate Mounting Chart for first three digits)

(1) Available with remote electronics only (2) Use A1P mounting option (3) Choose only sanitary mounting options (4) Available with 0-inch CSL only (5) Use P00X mounting option

(6) Use A1B mounting option(7) Use A8B mounting option (¼-inch NPT)(8) Choose from flange mounting only(9) FM approved with remote electronics only

Not all mounting options available with all sensing elements

7 Rmt. w/ (25 ft.) Tri-Ax Cable8 Rmt. w/ (50 ft.) Tri-Ax Cable9 Rmt. w/ (75 ft.) Tri-Ax CableA Rmt. w/ (10 ft.) Hi-Temp. CableB Rmt. w/ (25 ft.) 1st 10ft Hi-Temp. Cbl.C Rmt. w/ (35 ft.) 1st 10ft Hi-Temp. Cbl.D Rmt. w/ (50 ft.) 1st 10ft Hi-Temp. Cbl.

E Rmt. w/ (75 ft.) 1st 10ft Hi-Temp. Cbl.F Rmt. w/ (5 ft.) G.P. CableG Rmt. w/ (5 ft.) Tri-Ax CableH Rmt. w/ (10 ft.) Tri-Ax CableJ Rmt. w/ (35 ft.) Tri-Ax CableK Rmt. w/ (5 ft.) Hi-Temp. Cable

Notes: CSL (Cote-Shield Length) should extend through Nozzle + Typical "Wall Buildup" + 2 Inches

Sensing Element Application Sensing Element Pressure/Temperature Wetted Parts00 General purpose 700-1202-001 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK 700-1202-021 integral01 Floating roof with 700-1202-012 remote 13.8 bar @ 177°C (200 PSI @ 350°F) 316SS, Brass, cable attachment 700-1202-022 integral and PEEK and brass bottom weight02 General purpose, 700-1202-014 remote 13.8 bar @ 177°C (200 PSI @ 350°F) 316SS and PEEK longer insertion lengths 700-1202-024 integral with cable attachment and 316SS bottom weight03 Proximity 700-1202-018 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK 700-1202-028 integral with 76 mm (3) 316SS proximity plate04 General purpose, 700-1202-041 remote 69 bar @ 121°C (1000 PSI @ 250°F) 316SS and PEEK high temperature 700-1202-042 integral 20.7 bar @ 232°C (300 PSI @ 450°F) and pressure06 General purpose with 700-1202-031 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and FDA grade FDA approved 700-1202-032 integral PEEK materials of construction07 General purpose 700-1202-010 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK with Granular materials 700-1202-020 integral 7/8 inch dia. 316SS collar09 General purpose 700-1202-033 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and FDA grade Granular materials with 700-1202-034 integral PEEK with 7/8 inch dia. FDA approved 316SS collar materials of construction10 Corrosive liquids (2)(4)(9) 700-0001-018 remote 3.4 bar @ 149°C (50 PSI @ 300°F) PFA11 General purpose, 700-0201-005 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE higher pressure 13.8 bar @ 232°C (200 PSI @ 450°F) TFE compatibility required12 Corrosive material, 700-0201-005 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) Hastelloy C and TFE higher pressure Hastelloy C 13.8 bar @ 232°C (200 PSI @ 450°F)13 Sanitary (3) 700-0201-036 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316/316L SS and TFE 13.8 bar @ 232°C (200 PSI @ 300°F)14 General Purpose, 700-0202-002 int/rem 3.4 bar @ 149°C (50 PSI @ 300°F) 316SS and TFE low pressure 1.4 bar @ 232°C (20 PSI @ 450°F)15 Heavy duty, agitated 700-0202-043 remote 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE tanks or material 13.8 bar @ 232°C (200 PSI @ 450°F) with high bulk density (1) 16 High Integrity Seal for 700-0002-360 int/rem 34.5 bar @ 149°C (500 PSI @ 300°F) PFA Hazardous Materials17 Sanitary (3) lowpressure 700-0202-036 int/rem 3.4 bar @ 149°C (50 PSI @ 300°F) 316SS and TFE18 Corrosive material, 700-0001-022 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) TFE higher pressure with 34.5 bar @ 149°C (500 PSI @ 300°F) waterlike viscosity (4)19 Interface Measurement 700-0002-023 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE 34.5 bar @ 149°C (500 PSI @ 300°F) 20 Miniature Pilot 700-0209-002 remote 6.9 bar @ 121°C (100 PSI @ 250°F) 316 SS and TFE Plant Sensor (1)(7) 0 bar @ 232°C (0 PSI @ 450°F)Fly Ash Precipitators, Baghouse, and Economizers (1) (6) Application Sensing Element Pressure/Temperature Wetted Parts31 No hopper Installation 700-0029-001 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE 32 Hopper Installation 700-0029-002 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 200mm (8 inches) 33 Hopper Installation 700-0029-003 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 406mm (16 inches) 34 Hopper Instalation 700-0029-004 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 521mm (20.5 inches) 35 Hopper Installation 700-0029-005 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 635mm (25 inches) Plugged Chute Detection (1) (5) Application Sensing Element Pressure/Temperature Wetted Parts50 Flush Mount Sensor 700-0207-001 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and 305mm2 (12 inches2) Polyurethane heavy duty51 Flush Mount Sensor 700-0207-002 remote 0.1 bar @ 149°C (1 PSI @ 300°F) 304 SS and TFE 305mm2 (12 inches2) higher temperature52 Flush Mount Sensor 700-0207-003 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and Neoprene 305mm2 (12 inches2) with curved radius 153, 229, 305 mm (6, 9, or 12 inches)53 Flush Mount Sensor 700-0207-004 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 410 SS and UHMW 305mm2 (12 inches2) Polyethylene extra heavy duty55 Flush Mount Sensor 700-0207-006 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and 203mm2 (8 inches2) Polyurethane heavy dutyHigh Pressure / High Temperature60 High Pressure & Temp. 700-0204-038 remote 137.9 bar @ 93°C (2000 PSI @ 200°F) 316SS and Ceramic 68.9 bar @ 260°C (1000 PSI @ 500°F)61 High Temperature 700-0204-002 remote 0 bar @ 816°C (0 PSI @ 1500°F) 316SS and Ceramic62 High Pressure & Temp. 700-0204-048 remote 275.8 bar @316°C (4000 PSI @ 600°F) 316SSZZ Sensing Element Not Listed

Output0 8-16 mA

Housing

TechnologyP RF Admittance

InputT Two Wire Power Supply 13 to 30 Vdc

Measurement TypeL No Calibration, 2 pF Fixed PreloadP No Calibration, 0.5 pF Fixed Preload (High Sensitivity)M Manual CalibrationG Manual Calibration (High Sensitivity)

Electronics0 Integral1 Remote, no cable2 Rmt. w/ 3 m (10 ft.) G.P. cable3 Rmt. w/ 7.6 m (25 ft.) G.P. cable4 Rmt. w/ 10.6 m (35 ft.) G.P. cable5 Rmt. w/ 15.2 m (50 ft.) G.P. cable6 Rmt. w/ 23 m (75 ft.) G.P. cable

IL CSLxxxG 457 mm (18") 0 mm (0")xxxH 914 mm (36") 254 mm (10")xxxJ 914 mm (36") 0 mm (0")xxxK 1219 mm (48") 254 mm (10")xxxL 1524 mm (60") 254 mm (10")P00X IL/CSL OtherA1BX IL/CSL factory set for Fly AshxxxZ Other

IL CSLxxx1 457 mm (18") 152 mm (6")xxx2 305 mm (12") 152 mm (6")xxxA 152 mm (6") 51 mm (2")xxxB 305 mm (12") 51 mm (2")xxxC 305 mm (12") 89 mm (3.5")xxxD 457 mm (18") 51 mm (2")xxxE 457 mm (18") 89 mm (3.5")xxxF 457 mm (18") 254 mm (10")

Mounting Type (See separate Mounting Chart for first three digits)

7 Rmt. w/ (25 ft.) Tri-Ax Cable8 Rmt. w/ (50 ft.) Tri-Ax Cable9 Rmt. w/ (75 ft.) Tri-Ax CableA Rmt. w/ (10 ft.) Hi-Temp. CableB Rmt. w/ (25 ft.) 1st 10ft Hi-Temp. Cbl.C Rmt. w/ (35 ft.) 1st 10ft Hi-Temp. Cbl.D Rmt. w/ (50 ft.) 1st 10ft Hi-Temp. Cbl.

E Rmt. w/ (75 ft.) 1st 10ft Hi-Temp. Cbl.F Rmt. w/ (5 ft.) G.P. CableG Rmt. w/ (5 ft.) Tri-Ax CableH Rmt. w/ (10 ft.) Tri-Ax CableJ Rmt. w/ (35 ft.) Tri-Ax CableK Rmt. w/ (5 ft.) Hi-Temp. Cable

TP 0

NPT ThreadsA1B ¾" NPT 316SSA1C ¾" NPT Hastelloy CA1P ¾" NPT PFA

A2B 1" NPT 316SSA2C 1" NPT Hastelloy C

Sanitary TriClampsC2B 1" TriClamp 316SSC3B 1½" TriClamp 316SS

C4B 2" TriClamp 316SS

ANSI FlangesDA1 1" 150# RF 316/316L SSDB1 1½" 150# RF 316/316L SSDC1 2" 150# RF 316/316L SSDD1 2½" 150# RF 316/316L SSDE1 1" 300# RF 316/316L SSDF1 1½" 300# RF 316/316L SSDG1 2" 300# RF 316/316L SSDH1 2½" 300# RF 316/316L SSDI1 3" 150# RF 316/316L SSDJ1 3" 300# RF 316/316L SSDK1 4" 150# RF 316/316L SSDL1 4" 300# RF 316/316L SSDM1 6" 150# RF 316/316L SSDN1 6" 300# RF 316/316L SS

DA2 1" 150# RF CSDB2 1½" 150# RF CSDC2 2" 150# RF CSDD2 2½" 150# RF CSDE2 1" 300# RF CSDF2 1½" 300# RF CSDG2 2" 300# RF CSDH2 2½" 300# RF CSDI2 3" 150# RF CSDJ2 3" 300# RF CSDK2 4" 150# RF CSDL2 4" 300# RF CSDM2 6" 150# RF CSDN2 6" 300# RF CS

DIN FlangesE01 25 mm 16 bar RF 316/316L SSEP1 25 mm 40 bar RF 316/316L SSEQ1 50 mm 16 bar RF 316/316L SSER1 50 mm 40 bar RF 316/316L SSES1 80 mm 16 bar RF 316/316L SSET1 80 mm 40 bar RF 316/316L SSEU1 100 mm 16 bar RF 316/316L SSEV1 100 mm 40 bar RF 316/316L SSEW1 150 mm 16 bar RF 316/316L SSEX1 150 mm 40 bar RF 316/316L SS

E02 25 mm 16 bar RF CSEP2 25 mm 40 bar RF CSEQ2 50 mm 16 bar RF CSER2 50 mm 40 bar RF CSES2 80 mm 16 bar RF CSET2 80 mm 40 bar RF CSEU2 100 mm 16 bar RF CSEV2 100 mm 40 bar RF CSEW2 150 mm 16 bar RF CSEX2 150 mm 40 bar RF CS

NPT ThreadsA1B ¾" NPT 316SSA1C ¾" NPT Hastelloy CA1P ¾" NPT PFA

A2B 1" NPT 316SSA2C 1" NPT Hastelloy C

Sanitary TriClampsC2B 1" TriClamp 316SSC3B 1½" TriClamp 316SS

C4B 2" TriClamp 316SS

ANSI FlangesDA1 1" 150# RF 316/316L SSDB1 1½" 150# RF 316/316L SSDC1 2" 150# RF 316/316L SSDD1 2½" 150# RF 316/316L SSDE1 1" 300# RF 316/316L SSDF1 1½" 300# RF 316/316L SSDG1 2" 300# RF 316/316L SSDH1 2½" 300# RF 316/316L SSDI1 3" 150# RF 316/316L SSDJ1 3" 300# RF 316/316L SSDK1 4" 150# RF 316/316L SSDL1 4" 300# RF 316/316L SSDM1 6" 150# RF 316/316L SSDN1 6" 300# RF 316/316L SS

DA2 1" 150# RF CSDB2 1½" 150# RF CSDC2 2" 150# RF CSDD2 2½" 150# RF CSDE2 1" 300# RF CSDF2 1½" 300# RF CSDG2 2" 300# RF CSDH2 2½" 300# RF CSDI2 3" 150# RF CSDJ2 3" 300# RF CSDK2 4" 150# RF CSDL2 4" 300# RF CSDM2 6" 150# RF CSDN2 6" 300# RF CS

DIN FlangesE01 25 mm 16 bar RF 316/316L SSEP1 25 mm 40 bar RF 316/316L SSEQ1 50 mm 16 bar RF 316/316L SSER1 50 mm 40 bar RF 316/316L SSES1 80 mm 16 bar RF 316/316L SSET1 80 mm 40 bar RF 316/316L SSEU1 100 mm 16 bar RF 316/316L SSEV1 100 mm 40 bar RF 316/316L SSEW1 150 mm 16 bar RF 316/316L SSEX1 150 mm 40 bar RF 316/316L SS

E02 25 mm 16 bar RF CSEP2 25 mm 40 bar RF CSEQ2 50 mm 16 bar RF CSER2 50 mm 40 bar RF CSES2 80 mm 16 bar RF CSET2 80 mm 40 bar RF CSEU2 100 mm 16 bar RF CSEV2 100 mm 40 bar RF CSEW2 150 mm 16 bar RF CSEX2 150 mm 40 bar RF CS

(1) Available with remote electronics only (2) Use A1P mounting option (3) Choose only sanitary mounting options (4) Available with 0-inch CSL only (5) Use P00X mounting option

(6) Use A1B mounting option(7) Use A8B mounting option (¼-inch NPT)(8) Choose from flange mounting only(9) FM approved with remote electronics only

Not all mounting options available with all sensing elements

Notes: CSL (Cote-Shield Length) should extend through Nozzle + Typical "Wall Buildup" + 2 Inches

0 No Approvals, NEMA 4X/IP66, M20 X 1.5 conduit entries1 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries2 ATEX Approved, NEMA 4X/IP66, ¾” NPT conduit entries3 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries4 CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries5 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only6 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only7 CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only8 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – only9 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – onlyA CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – only

0 No Approvals, NEMA 4X/IP66, M20 X 1.5 conduit entries1 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries2 ATEX Approved, NEMA 4X/IP66, ¾” NPT conduit entries3 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries4 CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries5 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only6 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only7 CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only8 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – only9 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – onlyA CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – only

The Point™Model Numbering (continuedonnextpage)

(ContinuedonNextPage)

NOTE: All Calibration modes are built into the standard unit. Modes can be changed in the field as required (See Instruction Manual)

joseph
Chemtrols Industries Ltd. Emblem
Page 4: Chemtrols-India-AMETEK Drexelbrook-USA make,RF Point Level Switches

Sensing Element Application Sensing Element Pressure/Temperature Wetted Parts00 General purpose 700-1202-001 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK 700-1202-021 integral01 Floating roof with 700-1202-012 remote 13.8 bar @ 177°C (200 PSI @ 350°F) 316SS, Brass, cable attachment 700-1202-022 integral and PEEK and brass bottom weight02 General purpose, 700-1202-014 remote 13.8 bar @ 177°C (200 PSI @ 350°F) 316SS and PEEK longer insertion lengths 700-1202-024 integral with cable attachment and 316SS bottom weight03 Proximity 700-1202-018 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK 700-1202-028 integral with 76 mm (3) 316SS proximity plate04 General purpose, 700-1202-041 remote 69 bar @ 121°C (1000 PSI @ 250°F) 316SS and PEEK high temperature 700-1202-042 integral 20.7 bar @ 232°C (300 PSI @ 450°F) and pressure06 General purpose with 700-1202-031 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and FDA grade FDA approved 700-1202-032 integral PEEK materials of construction07 General purpose 700-1202-010 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK with Granular materials 700-1202-020 integral 7/8 inch dia. 316SS collar09 General purpose 700-1202-033 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and FDA grade Granular materials with 700-1202-034 integral PEEK with 7/8 inch dia. FDA approved 316SS collar materials of construction10 Corrosive liquids (2)(4)(9) 700-0001-018 remote 3.4 bar @ 149°C (50 PSI @ 300°F) PFA11 General purpose, 700-0201-005 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE higher pressure 13.8 bar @ 232°C (200 PSI @ 450°F) TFE compatibility required12 Corrosive material, 700-0201-005 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) Hastelloy C and TFE higher pressure Hastelloy C 13.8 bar @ 232°C (200 PSI @ 450°F)13 Sanitary (3) 700-0201-036 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316/316L SS and TFE 13.8 bar @ 232°C (200 PSI @ 300°F)14 General Purpose, 700-0202-002 int/rem 3.4 bar @ 149°C (50 PSI @ 300°F) 316SS and TFE low pressure 1.4 bar @ 232°C (20 PSI @ 450°F)15 Heavy duty, agitated 700-0202-043 remote 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE tanks or material 13.8 bar @ 232°C (200 PSI @ 450°F) with high bulk density (1) 16 High Integrity Seal for 700-0002-360 int/rem 34.5 bar @ 149°C (500 PSI @ 300°F) PFA Hazardous Materials17 Sanitary (3) lowpressure 700-0202-036 int/rem 3.4 bar @ 149°C (50 PSI @ 300°F) 316SS and TFE18 Corrosive material, 700-0001-022 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) TFE higher pressure with 34.5 bar @ 149°C (500 PSI @ 300°F) waterlike viscosity (4)19 Interface Measurement 700-0002-023 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE 34.5 bar @ 149°C (500 PSI @ 300°F) 20 Miniature Pilot 700-0209-002 remote 6.9 bar @ 121°C (100 PSI @ 250°F) 316 SS and TFE Plant Sensor (1)(7) 0 bar @ 232°C (0 PSI @ 450°F)Fly Ash Precipitators, Baghouse, and Economizers (1) (6) Application Sensing Element Pressure/Temperature Wetted Parts31 No hopper Installation 700-0029-001 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE 32 Hopper Installation 700-0029-002 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 200mm (8 inches) 33 Hopper Installation 700-0029-003 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 406mm (16 inches) 34 Hopper Instalation 700-0029-004 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 521mm (20.5 inches) 35 Hopper Installation 700-0029-005 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 635mm (25 inches) Plugged Chute Detection (1) (5) Application Sensing Element Pressure/Temperature Wetted Parts50 Flush Mount Sensor 700-0207-001 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and 305mm2 (12 inches2) Polyurethane heavy duty51 Flush Mount Sensor 700-0207-002 remote 0.1 bar @ 149°C (1 PSI @ 300°F) 304 SS and TFE 305mm2 (12 inches2) higher temperature52 Flush Mount Sensor 700-0207-003 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and Neoprene 305mm2 (12 inches2) with curved radius 153, 229, 305 mm (6, 9, or 12 inches)53 Flush Mount Sensor 700-0207-004 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 410 SS and UHMW 305mm2 (12 inches2) Polyethylene extra heavy duty55 Flush Mount Sensor 700-0207-006 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and 203mm2 (8 inches2) Polyurethane heavy dutyHigh Pressure / High Temperature60 High Pressure & Temp. 700-0204-038 remote 137.9 bar @ 93°C (2000 PSI @ 200°F) 316SS and Ceramic 68.9 bar @ 260°C (1000 PSI @ 500°F)61 High Temperature 700-0204-002 remote 0 bar @ 816°C (0 PSI @ 1500°F) 316SS and Ceramic62 High Pressure & Temp. 700-0204-048 remote 275.8 bar @316°C (4000 PSI @ 600°F) 316SSZZ Sensing Element Not Listed

Output1 One DPDT Relay, dry contacts, 5A, 120VAC (Min 100 mA / 12 VDC) 2 One DPDT Relay, gold plated contacts (Max 200 mA / 12 VDC)

Housing

TechnologyP RF Admittance

InputL Universal Power Supply 19-250 VAC, 18-200 VDC

Measurement TypeL No Calibration, 2 pF Fixed PreloadP No Calibration, 0.5 pF Fixed Preload (High Sensitivity)M Manual CalibrationG Manual Calibration (High Sensitivity)

Electronics0 Integral1 Remote, no cable2 Rmt. w/ 3 m (10 ft.) G.P. cable3 Rmt. w/ 7.6 m (25 ft.) G.P. cable4 Rmt. w/ 10.6 m (35 ft.) G.P. cable5 Rmt. w/ 15.2 m (50 ft.) G.P. cable6 Rmt. w/ 23 m (75 ft.) G.P. cable

IL CSLxxxG 457 mm (18") 0 mm (0")xxxH 914 mm (36") 254 mm (10")xxxJ 914 mm (36") 0 mm (0")xxxK 1219 mm (48") 254 mm (10")xxxL 1524 mm (60") 254 mm (10")P00X IL/CSL OtherA1BX IL/CSL factory set for Fly AshxxxZ Other

IL CSLxxx1 457 mm (18") 152 mm (6")xxx2 305 mm (12") 152 mm (6")xxxA 152 mm (6") 51 mm (2")xxxB 305 mm (12") 51 mm (2")xxxC 305 mm (12") 89 mm (3.5")xxxD 457 mm (18") 51 mm (2")xxxE 457 mm (18") 89 mm (3.5")xxxF 457 mm (18") 254 mm (10")

Mounting Type (See separate Mounting Chart for first three digits)

(1) Available with remote electronics only (2) Use A1P mounting option (3) Choose only sanitary mounting options (4) Available with 0-inch CSL only (5) Use P00X mounting option

(6) Use A1B mounting option(7) Use A8B mounting option (¼-inch NPT)(8) Choose from flange mounting only(9) FM approved with remote electronics only

Not all mounting options available with all sensing elements

7 Rmt. w/ (25 ft.) Tri-Ax Cable8 Rmt. w/ (50 ft.) Tri-Ax Cable9 Rmt. w/ (75 ft.) Tri-Ax CableA Rmt. w/ (10 ft.) Hi-Temp. CableB Rmt. w/ (25 ft.) 1st 10ft Hi-Temp. Cbl.C Rmt. w/ (35 ft.) 1st 10ft Hi-Temp. Cbl.D Rmt. w/ (50 ft.) 1st 10ft Hi-Temp. Cbl.

E Rmt. w/ (75 ft.) 1st 10ft Hi-Temp. Cbl.F Rmt. w/ (5 ft.) G.P. CableG Rmt. w/ (5 ft.) Tri-Ax CableH Rmt. w/ (10 ft.) Tri-Ax CableJ Rmt. w/ (35 ft.) Tri-Ax CableK Rmt. w/ (5 ft.) Hi-Temp. Cable

Notes: CSL (Cote-Shield Length) should extend through Nozzle + Typical "Wall Buildup" + 2 Inches

Sensing Element Application Sensing Element Pressure/Temperature Wetted Parts00 General purpose 700-1202-001 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK 700-1202-021 integral01 Floating roof with 700-1202-012 remote 13.8 bar @ 177°C (200 PSI @ 350°F) 316SS, Brass, cable attachment 700-1202-022 integral and PEEK and brass bottom weight02 General purpose, 700-1202-014 remote 13.8 bar @ 177°C (200 PSI @ 350°F) 316SS and PEEK longer insertion lengths 700-1202-024 integral with cable attachment and 316SS bottom weight03 Proximity 700-1202-018 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK 700-1202-028 integral with 76 mm (3) 316SS proximity plate04 General purpose, 700-1202-041 remote 69 bar @ 121°C (1000 PSI @ 250°F) 316SS and PEEK high temperature 700-1202-042 integral 20.7 bar @ 232°C (300 PSI @ 450°F) and pressure06 General purpose with 700-1202-031 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and FDA grade FDA approved 700-1202-032 integral PEEK materials of construction07 General purpose 700-1202-010 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and PEEK with Granular materials 700-1202-020 integral 7/8 inch dia. 316SS collar09 General purpose 700-1202-033 remote 13.8 bar @ 232°C (200 PSI @ 450°F) 316SS and FDA grade Granular materials with 700-1202-034 integral PEEK with 7/8 inch dia. FDA approved 316SS collar materials of construction10 Corrosive liquids (2)(4)(9) 700-0001-018 remote 3.4 bar @ 149°C (50 PSI @ 300°F) PFA11 General purpose, 700-0201-005 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE higher pressure 13.8 bar @ 232°C (200 PSI @ 450°F) TFE compatibility required12 Corrosive material, 700-0201-005 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) Hastelloy C and TFE higher pressure Hastelloy C 13.8 bar @ 232°C (200 PSI @ 450°F)13 Sanitary (3) 700-0201-036 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316/316L SS and TFE 13.8 bar @ 232°C (200 PSI @ 300°F)14 General Purpose, 700-0202-002 int/rem 3.4 bar @ 149°C (50 PSI @ 300°F) 316SS and TFE low pressure 1.4 bar @ 232°C (20 PSI @ 450°F)15 Heavy duty, agitated 700-0202-043 remote 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE tanks or material 13.8 bar @ 232°C (200 PSI @ 450°F) with high bulk density (1) 16 High Integrity Seal for 700-0002-360 int/rem 34.5 bar @ 149°C (500 PSI @ 300°F) PFA Hazardous Materials17 Sanitary (3) lowpressure 700-0202-036 int/rem 3.4 bar @ 149°C (50 PSI @ 300°F) 316SS and TFE18 Corrosive material, 700-0001-022 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) TFE higher pressure with 34.5 bar @ 149°C (500 PSI @ 300°F) waterlike viscosity (4)19 Interface Measurement 700-0002-023 int/rem 69 bar @ 38°C (1000 PSI @ 100°F) 316SS and TFE 34.5 bar @ 149°C (500 PSI @ 300°F) 20 Miniature Pilot 700-0209-002 remote 6.9 bar @ 121°C (100 PSI @ 250°F) 316 SS and TFE Plant Sensor (1)(7) 0 bar @ 232°C (0 PSI @ 450°F)Fly Ash Precipitators, Baghouse, and Economizers (1) (6) Application Sensing Element Pressure/Temperature Wetted Parts31 No hopper Installation 700-0029-001 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE 32 Hopper Installation 700-0029-002 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 200mm (8 inches) 33 Hopper Installation 700-0029-003 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 406mm (16 inches) 34 Hopper Instalation 700-0029-004 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 521mm (20.5 inches) 35 Hopper Installation 700-0029-005 remote 0.1 bar @ 260°C (2 PSI @ 500°F) 316SS and TFE up to 635mm (25 inches) Plugged Chute Detection (1) (5) Application Sensing Element Pressure/Temperature Wetted Parts50 Flush Mount Sensor 700-0207-001 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and 305mm2 (12 inches2) Polyurethane heavy duty51 Flush Mount Sensor 700-0207-002 remote 0.1 bar @ 149°C (1 PSI @ 300°F) 304 SS and TFE 305mm2 (12 inches2) higher temperature52 Flush Mount Sensor 700-0207-003 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and Neoprene 305mm2 (12 inches2) with curved radius 153, 229, 305 mm (6, 9, or 12 inches)53 Flush Mount Sensor 700-0207-004 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 410 SS and UHMW 305mm2 (12 inches2) Polyethylene extra heavy duty55 Flush Mount Sensor 700-0207-006 remote 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and 203mm2 (8 inches2) Polyurethane heavy dutyHigh Pressure / High Temperature60 High Pressure & Temp. 700-0204-038 remote 137.9 bar @ 93°C (2000 PSI @ 200°F) 316SS and Ceramic 68.9 bar @ 260°C (1000 PSI @ 500°F)61 High Temperature 700-0204-002 remote 0 bar @ 816°C (0 PSI @ 1500°F) 316SS and Ceramic62 High Pressure & Temp. 700-0204-048 remote 275.8 bar @316°C (4000 PSI @ 600°F) 316SSZZ Sensing Element Not Listed

Output0 8-16 mA

Housing

TechnologyP RF Admittance

InputT Two Wire Power Supply 13 to 30 Vdc

Measurement TypeL No Calibration, 2 pF Fixed PreloadP No Calibration, 0.5 pF Fixed Preload (High Sensitivity)M Manual CalibrationG Manual Calibration (High Sensitivity)

Electronics0 Integral1 Remote, no cable2 Rmt. w/ 3 m (10 ft.) G.P. cable3 Rmt. w/ 7.6 m (25 ft.) G.P. cable4 Rmt. w/ 10.6 m (35 ft.) G.P. cable5 Rmt. w/ 15.2 m (50 ft.) G.P. cable6 Rmt. w/ 23 m (75 ft.) G.P. cable

IL CSLxxxG 457 mm (18") 0 mm (0")xxxH 914 mm (36") 254 mm (10")xxxJ 914 mm (36") 0 mm (0")xxxK 1219 mm (48") 254 mm (10")xxxL 1524 mm (60") 254 mm (10")P00X IL/CSL OtherA1BX IL/CSL factory set for Fly AshxxxZ Other

IL CSLxxx1 457 mm (18") 152 mm (6")xxx2 305 mm (12") 152 mm (6")xxxA 152 mm (6") 51 mm (2")xxxB 305 mm (12") 51 mm (2")xxxC 305 mm (12") 89 mm (3.5")xxxD 457 mm (18") 51 mm (2")xxxE 457 mm (18") 89 mm (3.5")xxxF 457 mm (18") 254 mm (10")

Mounting Type (See separate Mounting Chart for first three digits)

7 Rmt. w/ (25 ft.) Tri-Ax Cable8 Rmt. w/ (50 ft.) Tri-Ax Cable9 Rmt. w/ (75 ft.) Tri-Ax CableA Rmt. w/ (10 ft.) Hi-Temp. CableB Rmt. w/ (25 ft.) 1st 10ft Hi-Temp. Cbl.C Rmt. w/ (35 ft.) 1st 10ft Hi-Temp. Cbl.D Rmt. w/ (50 ft.) 1st 10ft Hi-Temp. Cbl.

E Rmt. w/ (75 ft.) 1st 10ft Hi-Temp. Cbl.F Rmt. w/ (5 ft.) G.P. CableG Rmt. w/ (5 ft.) Tri-Ax CableH Rmt. w/ (10 ft.) Tri-Ax CableJ Rmt. w/ (35 ft.) Tri-Ax CableK Rmt. w/ (5 ft.) Hi-Temp. Cable

TP 0

NPT ThreadsA1B ¾" NPT 316SSA1C ¾" NPT Hastelloy CA1P ¾" NPT PFA

A2B 1" NPT 316SSA2C 1" NPT Hastelloy C

Sanitary TriClampsC2B 1" TriClamp 316SSC3B 1½" TriClamp 316SS

C4B 2" TriClamp 316SS

ANSI FlangesDA1 1" 150# RF 316/316L SSDB1 1½" 150# RF 316/316L SSDC1 2" 150# RF 316/316L SSDD1 2½" 150# RF 316/316L SSDE1 1" 300# RF 316/316L SSDF1 1½" 300# RF 316/316L SSDG1 2" 300# RF 316/316L SSDH1 2½" 300# RF 316/316L SSDI1 3" 150# RF 316/316L SSDJ1 3" 300# RF 316/316L SSDK1 4" 150# RF 316/316L SSDL1 4" 300# RF 316/316L SSDM1 6" 150# RF 316/316L SSDN1 6" 300# RF 316/316L SS

DA2 1" 150# RF CSDB2 1½" 150# RF CSDC2 2" 150# RF CSDD2 2½" 150# RF CSDE2 1" 300# RF CSDF2 1½" 300# RF CSDG2 2" 300# RF CSDH2 2½" 300# RF CSDI2 3" 150# RF CSDJ2 3" 300# RF CSDK2 4" 150# RF CSDL2 4" 300# RF CSDM2 6" 150# RF CSDN2 6" 300# RF CS

DIN FlangesE01 25 mm 16 bar RF 316/316L SSEP1 25 mm 40 bar RF 316/316L SSEQ1 50 mm 16 bar RF 316/316L SSER1 50 mm 40 bar RF 316/316L SSES1 80 mm 16 bar RF 316/316L SSET1 80 mm 40 bar RF 316/316L SSEU1 100 mm 16 bar RF 316/316L SSEV1 100 mm 40 bar RF 316/316L SSEW1 150 mm 16 bar RF 316/316L SSEX1 150 mm 40 bar RF 316/316L SS

E02 25 mm 16 bar RF CSEP2 25 mm 40 bar RF CSEQ2 50 mm 16 bar RF CSER2 50 mm 40 bar RF CSES2 80 mm 16 bar RF CSET2 80 mm 40 bar RF CSEU2 100 mm 16 bar RF CSEV2 100 mm 40 bar RF CSEW2 150 mm 16 bar RF CSEX2 150 mm 40 bar RF CS

NPT ThreadsA1B ¾" NPT 316SSA1C ¾" NPT Hastelloy CA1P ¾" NPT PFA

A2B 1" NPT 316SSA2C 1" NPT Hastelloy C

Sanitary TriClampsC2B 1" TriClamp 316SSC3B 1½" TriClamp 316SS

C4B 2" TriClamp 316SS

ANSI FlangesDA1 1" 150# RF 316/316L SSDB1 1½" 150# RF 316/316L SSDC1 2" 150# RF 316/316L SSDD1 2½" 150# RF 316/316L SSDE1 1" 300# RF 316/316L SSDF1 1½" 300# RF 316/316L SSDG1 2" 300# RF 316/316L SSDH1 2½" 300# RF 316/316L SSDI1 3" 150# RF 316/316L SSDJ1 3" 300# RF 316/316L SSDK1 4" 150# RF 316/316L SSDL1 4" 300# RF 316/316L SSDM1 6" 150# RF 316/316L SSDN1 6" 300# RF 316/316L SS

DA2 1" 150# RF CSDB2 1½" 150# RF CSDC2 2" 150# RF CSDD2 2½" 150# RF CSDE2 1" 300# RF CSDF2 1½" 300# RF CSDG2 2" 300# RF CSDH2 2½" 300# RF CSDI2 3" 150# RF CSDJ2 3" 300# RF CSDK2 4" 150# RF CSDL2 4" 300# RF CSDM2 6" 150# RF CSDN2 6" 300# RF CS

DIN FlangesE01 25 mm 16 bar RF 316/316L SSEP1 25 mm 40 bar RF 316/316L SSEQ1 50 mm 16 bar RF 316/316L SSER1 50 mm 40 bar RF 316/316L SSES1 80 mm 16 bar RF 316/316L SSET1 80 mm 40 bar RF 316/316L SSEU1 100 mm 16 bar RF 316/316L SSEV1 100 mm 40 bar RF 316/316L SSEW1 150 mm 16 bar RF 316/316L SSEX1 150 mm 40 bar RF 316/316L SS

E02 25 mm 16 bar RF CSEP2 25 mm 40 bar RF CSEQ2 50 mm 16 bar RF CSER2 50 mm 40 bar RF CSES2 80 mm 16 bar RF CSET2 80 mm 40 bar RF CSEU2 100 mm 16 bar RF CSEV2 100 mm 40 bar RF CSEW2 150 mm 16 bar RF CSEX2 150 mm 40 bar RF CS

(1) Available with remote electronics only (2) Use A1P mounting option (3) Choose only sanitary mounting options (4) Available with 0-inch CSL only (5) Use P00X mounting option

(6) Use A1B mounting option(7) Use A8B mounting option (¼-inch NPT)(8) Choose from flange mounting only(9) FM approved with remote electronics only

Not all mounting options available with all sensing elements

Notes: CSL (Cote-Shield Length) should extend through Nozzle + Typical "Wall Buildup" + 2 Inches

0 No Approvals, NEMA 4X/IP66, M20 X 1.5 conduit entries1 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries2 ATEX Approved, NEMA 4X/IP66, ¾” NPT conduit entries3 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries4 CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries5 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only6 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only7 CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only8 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – only9 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – onlyA CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – only

0 No Approvals, NEMA 4X/IP66, M20 X 1.5 conduit entries1 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries2 ATEX Approved, NEMA 4X/IP66, ¾” NPT conduit entries3 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries4 CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries5 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only6 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only7 CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Perm-a-Seal sensors – only8 No Approvals, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – only9 FM approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – onlyA CSA Approved, NEMA 4X/IP66, ¾” NPT conduit entries, Dual Seal, Non Perm-a-Seal sensors – only

DREXELBROOK®

205KeithValleyRoad,Horsham,PA19044U.S.A.Tel:215-674-1234Fax:215674-2731Email:[email protected]

Web:www.drexelbrook.com

©AMETEK,Inc.Allrightsreserved.•PrintedintheU.S.A.•PNL1-A•EDO#1-10-102•Issue#11

Model Numbering(ContinuedfromPreviousPage)

joseph
Chemtrols Industries Ltd. Emblem
Page 5: Chemtrols-India-AMETEK Drexelbrook-USA make,RF Point Level Switches

Model Numbering - Transmitter

TechnologyT Impulse TDR

T X XX 0

Safety Level0

Electrical Connection0 3/4" NPT1 M 20

Approvals1 FM / FMc IS2 FM / FMc XP3 ATEX Ex ia4 ATEX Ex dia6 FM / FMC IS with Dual Seal7 FM / FMC XP with Dual Seal

Signal Output1 (1) 24 VDC, 2-wire 4 - 20 mA, HART output

DREXELBROOK®

205 Keith Valley Road, Horsham, PA 19044 U.S.A.T l 215 674 1234 F 215 674 2731

IMPULSE™ Series

CHEMTROLS INDUSTRIES LTD. Amar Hill, Saki Vihar Road, Powai, Mumbai- 72, INDIA. Ph : +91 22 28575089, +91 22 67151200, 67151217 Fax : +91 22 28571913 Email: [email protected] Web: www.chemtrols.com Forward Your Enquiries to: [email protected] Phone: +91 22 67151217

Page 6: Chemtrols-India-AMETEK Drexelbrook-USA make,RF Point Level Switches

….

Page 7: Chemtrols-India-AMETEK Drexelbrook-USA make,RF Point Level Switches

Top Related