• Measuringlevels,pressure,temparature,flowandmoreparamateresinwells,boreholes,sewersandriversorlakes
• Groundwaterlevelmonitoring.Chatter™DataLoggerisespecially usefulinplaceswithoutmainpowersupply,asitisdevelopedfor havingaverylonglifespanonthebuilt-inbattery.• Stormflowlogging,activatedbylevel-triggeroranaloglimit. Loggingofamount,duranceandtimeofstormflows.
Application
GeneralChatter™DataLoggerisdesignedformonitoringdrinkingwaterandwastewaterinstallations.Chatter™DataLoggerhasabuilt-inmulti-channeldatalogger,aGSM/GPRSmodemandabatteryensuringupto5-10yearsofcontinuousoperation.
Theembeddedsoftwareactivatestherequireddigitalandanaloginputs,andtime-stampeddataarestoredatselectableintervals.Threedifferenttypesofcallcanbeselected;DataforstandardSQL-database,SCADAsystemorase-mailorSMS,andthecallscanbescheduledtousercontrolledintervals,transferredusingtheGSM/GPRSnet.
InstallationandconfigurationofdataloggingareverysimplewiththeMJKusersoftware.DatafromtheSQLdatabasecanbetransferredtolargerSCADAsystemsusingChatterCNSplug-in.
Chatter™DataLoggerisavailableintwodifferentversions:oneforpipemountingandoneforwallmount.
• TransmitsdataandalarmstostandardSQLdatabaseusingGSM/GPRSnetwork• TransmitsdataandalarmstoSCADAsystemsusingModbus®RTUprotocol overGSM/GPRSnetwork• Datatransmissionbye-mailtouptofoure-mailaddresses: • Datadirectlyinthemailbody • DataasattachedCSVfileinthemail. • DatafilecanbedisplayedbyChatterLinkPCsoftware• TransmitslivedataandalarmsasSMSmessagetouptofourrecipients• AlarmscanbesentaloneoralongwithothercommunicationasSMS.
Features
Chatter™
EN6.10CHATTERDATASHEET1402DATASHEET
6.10
DATALOGGERWITHINTEGRATEDMODEM
Chatter™ Data Logger
Specifications
Four-In-One
Chatter™ Data Logger
Powersupply Built-in3,6VDC,19Ahlithiumbattery
Performance Betterthan5years@1measurement/dayand1call/day
Clock Real-timeclock,24-hourclock
Memorystorage DBVersion:>100.000measuredvalues(date-andtime-stamped)RTUandE-mailversion:90.000measuredvalues(date-andtimestamped)
Logintervals 1,2,510min,1,2,4,8,12or24hours
EventLogintervals 1,2,510min,1,2,4,8,12or24hours
Callintervals 1,2,4,8,12or24hours,and10,25,50100,250,500or1000Logs
Communication Build-inGSM/GPRSquad-band850/900/1800/1900MHzmodemw/on-boardSIM-cardholder
ExternalCommunicationProtocol
MJKProprietaryprotokolforDBVersion,Modbus®RTU-mode,Modbus®TCPorCOMLI®forRTUversion
Interface1pcs.RS485forSerialDatainput1pcs.USB1,1typeminiB,female1pcs.MMCX,female,forantenna
Antenna Pipe:Built-inGSM/GPRSAntenna-Dualband,Amplification0dB,Frequency900/1800MHz
Mounting InPipewithinnerdiameterØ63-Ø106mmoronawall
Enclosure IP67
Materials Pipe:PC-ASA(top)andaluminium(base)Wall:Glas-reinforcedPC(polycarbonate)
Temperaturerange -20…60°C
Airhumidity Max.95%relative
Weight Pipemounting:1,8kgWallmounting:0,7kg
CEapprovals EN61000-6-1:2007,EN61000-6-3:2007
Input and Output 4AI/4DI/1RS485
Digitalinputs 4pcs.2-5VDC(min.timeforstate1second)
Analoginputs 4pcs.0-2,5VDC
SerialDatainput 1pcs.RS-485Modbus®comportformax.4unitsModbus®RTU-mode,9600baud,2-wireRS-485,Mastermode,Function3,Readonly
PowersupplyforI/O1pcs.3,6VDC1pcs.3,6VDCON/OFF-controlled1pcs.5VDCON/OFF-controlled,option+10or+15VDC.
Accuracy AI:Betterthan±1%FS
Resolution AI:10bit,inputimpedance:min.10Kohm
Database Server
Serverrequirements MicrosoftServer2008R2,IISv.7(InternetInformationServices)MicrosoftSQLDatabase2008R2ExpressEdition
Networkrequirements. MPLS/APN(Multi-ProtocolLabelSwitching)orinternetaccess
Asourproductsaredevelopedcontinously,wereservetherigthtomakeanychangeswithoutpriornotice.
AsaRTUwithdirectcommunicationtoaScadasystem.
Datacanbesentine-mailstoastandardemailaddress.
Chatter™DataLoggermeasuresandstoresdatainthedataloggerandcantransmitin4differentmodes:
Chatter™DataLoggercansendalarmsandstatusofthemeasurementsasSMSmessages
SendsdatatoaSQLdatabase,wheremeasurementsandalarmscanbetransferredtoe.g.aScadasystem
Chatter™ Data LoggerElectrical Connections
USBUSB
SIM card
ON OFF
Battery
ANT.1
ANT.2 ANT.3
DI 1
DI 2
DI 3
DI 4
AI 1
AI 2
AI 3
AI 4
GN
D
GN
D
+5/
10/
15V
GN
D
3V6-
A
GN
D
GN
D
A B GN
D
3V6-
B
GN
D
RS485
Accessories Chatter Link™
Designedforforsetup,configurationandviewingonlinedatathroughUSBconnection.
Expert Digital Hydrostatic Level transmitters.
• HydrostaticPiezo-resistiverelativemeasuringprinciple.
• RS485digitaloutput,Modbus,levelandTemperaturesignals.
• Measuringrange:0–3m…300m(0-10ft..1000ft)
• Supplyvoltage:3,5-12VDC• Accuracy,betterthan±0.25%FS@+10to30°C
Dimensions
144
156
Ø20
83 79150 mm
101 mm
190 mm
Ø 63 - 106 mmIndre rørdiameter
190
150
101
Inner Pipe dia.Ø 63 - Ø106
Wallmounting:
Pipemounting:
Chatter™ Data Logger
Order Numbers Chatter™ Data Logger
204105 Chatter™DataLoggerGSM/GPRSfortubemounting
204110 Chatter™DataLoggerGSM/GPRSforwallmounting
204122 Chatter™DataLoggerGSM/GPRSforwallmounting,10-30VDC(3,7VLi-Ion)
204125 Chatter™DataLoggerGSM/GPRSforwallmounting,230VAC/12VDC
Accessories
840134 Chatter™SystemSoftwareDVD
840400 ChatterLink™
840128 Chatter™DataLoggerNotificationSystem.MustrunonthesameserverasChatterDBSystem
840135 Chatter™DataLoggerSetupTool
521751 MountingwedgekitfortubeØ63-92mm,3x3pcs.Metal,wedgesizes:1,2,3and4
521752 MountingwedgekitfortubeØ84-106mm,3x3pcs.Metal,wedgesizes:4,5and6
521755 Wedgescrews,kitwith3pcs.
521757 Padlockbracket,Ø8mm
521760 GasketforChatter™DataLoggerbase/tube
521761 GasketforChatter™DataLoggertop/base
521762 GasketforChatter™DataLoggercoverplate
550246 Battery3.6V,19Ah
569108 Screw,self-tapping,KB50x14
569123 Screw,self-tapping,KB35x7
571055 Rubberband,60mm,folded
691095 USBCable,Mini/USB
691098 USBplug,minitominiforpanelmounting,IP67
Antennas Seedatasheet:EN6.26GSM-GPRSAntennasDatasheet
ExpertHydrostaticLevelTransmitters Seedatasheet:EN2.75ExpertDatasheet
MJKAutomationApSByageren7DK-2850NærumDenmark
Tel +4545560656Fax+4545560646
www.mjk.com
C
ERT I F I E D
IS
O 9001-2008
Connect,MµConnect,Chatter,MagFlux,Oxix,pHixcompact,ShuttleandSuSixareregistreredtrademarksofMJKAutomationApS.©2013Xylem,Inc.