Characterization and Utilization of Cement Kiln Dusts (CKDs)
as Partial Replacements of Portland Cement
by
Om Shervan Khanna
A thesis submitted in conformity with the requirements
for the degree of Doctor of Philosophy
Department of Civil Engineering
University of Toronto
© Copyright by Om Shervan Khanna (2009)
ii
Characterization and Utilization of Cement Kiln Dusts (CKDs)
as Partial Replacements of Portland Cement Doctor of Philosophy, 2009
Om Shervan Khanna
Department of Civil Engineering University of Toronto
Abstract
The characteristics of cement kiln dusts (CKDs) and their effects as partial replacement
of Portland Cement (PC) were studied in this research program. The cement industry is
currently under pressure to reduce greenhouse gas (GHG) emissions and solid by-
products in the form of CKDs. The use of CKDs in concrete has the potential to
substantially reduce the environmental impact of their disposal and create significant cost
and energy savings to the cement industry.
Studies have shown that CKDs can be used as a partial substitute of PC in a range of 5 –
15%, by mass. Although the use of CKDs is promising, there is very little understanding
of their effects in CKD-PC blends. Previous studies provide variable and often
conflicting results. The reasons for the inconsistent results are not obvious due to a lack
of material characterization data. The characteristics of a CKD must be well-defined in
order to understand its potential impact in concrete.
The materials used in this study were two different types of PC (normal and moderate
sulfate resistant) and seven CKDs. The CKDs used in this study were selected to provide
a representation of those available in North America from the three major types of
cement manufacturing processes: wet, long-dry, and preheater/precalciner. The CKDs
have a wide range of chemical and physical composition based on different raw material
sources and technologies. Two fillers (limestone powder and quartz powder) were also
used to compare their effects to that of CKDs at an equivalent replacement of PC.
iii
The first objective of this study was to conduct a comprehensive composition analysis of
CKDs and compare their characteristics to PC. CKDs are unique materials that must be
analyzed differently from PC for accurate chemical and physical analysis. The present
study identifies the chemical and physical analytical methods that should be used for
CKDs. The study also introduced a method to quantify the relative abundance of the
different mineralogical phases within CKDs. It was found that CKDs can contain
significant amounts of amorphous material (>30%) and clinker compounds (>20%) and
small amounts of slag and/or flyash (<5%) and calcium langbeinite (<5%). The
dissolution of ionic species and composition of the liquid phase play an important role in
PC hydration. The dissolved ion contributions from CKDs were compared to PC using
dilute stirred suspensions at 10 minutes and it was found that the ion contributions from
CKDs are qualitatively the same as the ion contributions from PC, with the exception of
chloride ions.
The second objective was to utilize the material characterization analysis to determine the
relationships among the composition properties of CKD-PC blends and their effects on
fresh and hardened properties. The study found that CKDs from preheater/precalciner
kilns have different effects on workability and heat evolution than CKDs from wet and
long-dry kilns due to the presence of very reactive and high free lime contents (>20%).
The blends with the two CKDs from preheater/precalciner plants had higher paste water
demand, lower mortar flows, and higher heat generation during initial hydrolysis in
comparison to all other CKD-PC blends and control cements. The hardened properties of
CKD as a partial substitute of PC appear to be governed by the sulfate content of the
CKD-PC blend (the form of the CKD sulfate is not significant). According to analysis of
the ASTM expansion in limewater test results, the CKD-PC blend sulfate content should
be less than ~0.40% above the optimum sulfate content of the PC. It was also found that
the sulfate contribution of CKD behaves similar to gypsum. Therefore, CKD-PC blends
could be optimized for sulfate content by using CKD as a partial substitute of gypsum
during the grinding process to control the early hydration of C3A. The wet and long-dry
kiln CKDs contain significant amounts of calcium carbonate (>20%) which could also be
used as partial replacement of limestone filler in PC.
iv
Acknowledgments
I wish to express my sincere gratitude to Professor Doug Hooton, my supervisor, for his
excellent guidance and invaluable advice during this investigation. Thanks are also due to
Professor Hooton for the facilities extended to me at University of Toronto.
This project was initiated by the Products and Quality Department of Lafarge North
America Centre for Technical Services in Montreal under the guidance of Mr. Bruce
Blair, Dr. Anik Delagrave, and Ms. Claude Lauzon. Acknowledgement is made of their
generous assistance and valuable cooperation throughout the research program. I wish to
extend my deepest thanks and appreciation to Dr. Laurent Barcelo of Lafarge North
America for his helpful suggestions and interest in this investigation. Dr. Barcelo also
reviewed this manuscript during the preparation of the dissertation. Thanks are also
extended to these Lafarge personnel who shared their technical knowledge and expertise
via personal meetings and/or email exchanges: Dr. Jean Philippe Perez, Dr. Ellis Gartner,
and Mr. Paul Lehoux. Thanks are due to Lafarge laboratory technicians Rino Lisella and
Patricia Martin who shared their expertise and helped in preparing many of the
specimens. Thanks also to the many other laboratory researchers and staff of Lafarge for
providing assistance: Mr. Denis Belanger, Mr. Denis Leblanc, Ms. Sona Babikan, Mr.
Claude Verville, Ms. Julie Morissette, Ms. Lorraine Phang, and Mr. Bernard Brochard.
Thanks are also due to my colleagues at the University of Toronto. I wish to extend my
gratitude to Dr. Terry Ramlochan for providing technical advice periodically throughout
the course of this project, particularly with the CKD phase quantification. I would also
like to acknowledge the help provided by other members of the Concrete Materials
Group: Dr. Gustavo Julio-Betancourt for his helpful discussions, and Ms. Ursula Nytko
and Ms. Olga Perebatova for providing guidance and help with the materials and
equipment. Thanks are also due to Dr. S. Petrov from the Department of Chemistry for
assisting with the CKD phase quantification and Mr. Dan Mathers from the Department
of Chemistry for his help in analyzing some of the solution samples.
v
Sincere thanks to my supervising committee members Dr. Brenda McCabe and Dr.
Murray Grabinsky for their insightful questions and comments while the thesis was in
progress. I would also like to thank Dr. Daman Panesar for very supportive discussions
during my Ph.D and reviewing this dissertation.
Further, the author is indebted to Lafarge North America, the Natural Sciences and
Engineering Research Council (NSERC), and the Ontario Graduate Scholarship (OGS)
Program for providing financial support throughout the project.
My thanks are also due to my wife, children, and family members for their support and
understanding throughout the course of this project.
vi
Table of Contents
1.0 INTRODUCTION .................................................................................................. 1
1.1 Background ......................................................................................................... 1
1.2 Problem Statement .............................................................................................. 2
1.3 Incentives and Objectives of This Study ............................................................ 4
1.4 Summary of Chapters ......................................................................................... 6
2.0 LITERATURE REVIEW ....................................................................................... 8
2.1 CKD Manufacture and Management .................................................................. 8
2.1.1 Portland Cement Manufacture Overview ................................................... 8
2.1.2 CKD Generation ....................................................................................... 17
2.1.3 Fresh and Landfill CKD............................................................................ 20
2.1.4 CKD Applications: Cement Industry Perspective .................................... 21
2.1.5 Costs Associated with CKD Disposal....................................................... 22
2.1.6 CKD Environmental Considerations ........................................................ 23
2.2 CKD and Portland Cement ............................................................................... 24
2.2.1 Chemical Properties .................................................................................. 24
2.2.2 Mineralogical Properties........................................................................... 26
2.2.3 Physical Properties.................................................................................... 29
2.2.4 CKD Types ............................................................................................... 32
2.2.5 Variability of CKD from a Single Plant ................................................... 34
2.3 Portland Cement Hydration .............................................................................. 35
2.3.1 Initial Hydrolysis ...................................................................................... 37
2.3.2 Induction ................................................................................................... 38
2.3.3 Acceleration .............................................................................................. 39
2.3.4 Deceleration .............................................................................................. 40
2.3.5 Slow Continued Reaction ......................................................................... 41
2.4 Effects of CKD Properties and PC Dilution ..................................................... 41
2.4.1 Calcium Carbonate.................................................................................... 41
2.4.2 Quartz........................................................................................................ 44
2.4.3 Clays ......................................................................................................... 44
vii
2.4.4 Free Lime and Calcium Hydroxide........................................................... 45
2.4.5 Magnesia ................................................................................................... 48
2.4.6 Sulfate ....................................................................................................... 49
2.4.7 Chloride..................................................................................................... 54
2.4.8 Alkalis ....................................................................................................... 57
2.4.9 Clinker Phases........................................................................................... 58
2.4.10 Physical Properties.................................................................................... 58
2.5 CKD-PC............................................................................................................ 60
2.5.1 CKD-PC Material Characterization.......................................................... 62
2.5.1.1 CKD-PC Chemical Composition...................................................... 62
2.5.1.2 CKD-PC Mineralogical Composition............................................... 66
2.5.1.3 CKD-PC Physical Composition........................................................ 68
2.5.2 Workability ............................................................................................... 69
2.5.3 Setting Time.............................................................................................. 77
2.5.4 Hydration Kinetics .................................................................................... 82
2.5.5 Compressive Strength ............................................................................... 87
2.5.6 Flexural and Tensile Strength ................................................................. 103
2.5.7 Volume Stability ..................................................................................... 106
2.5.7.1 Soundness ....................................................................................... 106
2.5.7.2 Drying Shrinkage ............................................................................ 108
2.5.7.3 Volume Stability Summary............................................................. 112
2.5.8 Durability ................................................................................................ 113
2.5.8.1 Alkali-Aggregate Reaction ............................................................. 113
2.5.8.2 Steel Corrosion................................................................................ 116
2.5.8.3 Permeability .................................................................................... 121
2.5.8.4 Freezing and Thawing..................................................................... 123
2.5.8.5 External Sulfate Resistance............................................................. 125
2.5.8.6 Durability Summary........................................................................ 126
viii
3.0 MATERIALS AND EXPERIMENTAL DETAILS........................................... 127
3.1 Materials ......................................................................................................... 127
3.2 Testing of Raw Materials................................................................................ 129
3.2.1 Chemical Properties ................................................................................ 129
3.2.2 Mineralogical Properties......................................................................... 129
3.2.3 Physical Properties.................................................................................. 130
3.2.4 Dilute Stirred Suspensions...................................................................... 130
3.3 CKD-PC Blends.............................................................................................. 131
3.3.1 Heat of Hydration ................................................................................... 131
3.3.2 Normal Consistency................................................................................ 133
3.3.3 Initial Setting Time ................................................................................. 133
3.3.4 Flow ........................................................................................................ 134
3.3.5 Compressive Strength ............................................................................. 134
3.3.6 Expansion in Limewater ......................................................................... 134
3.3.7 Autoclave Expansion .............................................................................. 135
3.3.8 Alkali Silica Reactivity ........................................................................... 135
4.0 RESULTS AND DISCUSSION......................................................................... 138
4.1 Material Characterization................................................................................ 138
4.1.1 Chemical Properties ................................................................................ 138
4.1.2 Mineralogical Properties......................................................................... 144
4.1.3 Physical Properties.................................................................................. 151
4.1.4 CKD Dissolution Analysis...................................................................... 158
4.2 CKD-PC Blends.............................................................................................. 162
4.2.1 Kinetics ................................................................................................... 167
4.2.1.1 Heat of Hydration ........................................................................... 167
4.2.2 Physical Properties of Hydration ............................................................ 195
4.2.2.1 Normal Consistency........................................................................ 195
4.2.2.2 Flow ................................................................................................ 202
4.2.2.3 Initial Setting Time ......................................................................... 210
4.2.2.4 Compressive Strength ..................................................................... 218
4.2.3 Volume Stability and Durability............................................................. 230
ix
4.2.3.1 Expansion in Limewater ................................................................. 230
4.2.3.2 Autoclave Expansion ...................................................................... 236
4.2.3.3 Alkali Silica Reactivity ................................................................... 242
5.0 MAIN CONTRIBUTIONS OF THE THESIS ................................................... 246
5.1 CKD Characterization..................................................................................... 246
5.2 CKD-PC Blends.............................................................................................. 248
6.0 CONCLUSIONS................................................................................................. 252
7.0 RECOMMENDATIONS FOR FUTURE WORK ............................................. 254
8.0 REFERENCES ................................................................................................... 257
x
List of Tables
Table 2.1 Kiln material transformations (Manias, 2004) 12
Table 2.2 Summary of operation data on different kiln systems (Manias, 2004) 13
Table 2.3 Melting points and relative volatiles of different compounds in the kiln burning zone (Manias, 2004) 18
Table 2.4 Typical costs associated with CKD disposal, $/tonne (Kessler, 1995) 23
Table 2.5 CKD chemical oxide composition, free lime, and loss on ignition, and statistical analysis of 63 published datasets (Sreekrishnavilasam et al., 2006) 25
Table 2.6 Portland cement chemical oxide composition, total alkali content, and loss on ignition (Tennis and Bhatty, 2006) 25
Table 2.7 Mineralogical composition of U.S. CKD samples (Hawkins et al., 2004) 27
Table 2.8 Portland cement average bogue compound and Blaine fineness in 2004 (Tennis and Bhatty, 2006) 29
Table 2.9 CKD oxide composition and statistical analysis of intermittent daily samples collected from a single kiln (long-dry process) over a 3 year period (2005 – 2008) in North America (Lafarge, 2009) 34
Table 2.10 Summary of previous CKD-PC studies from literature review 61
Table 2.11 Chemical and physical composition of CKD: from CKD-PC literature review 64
Table 2.12 Chemical and physical composition of PC: from CKD-PC literature review 65
Table 2.13 Mineralogical composition of CKD: from CKD-PC literature review 67
xi
Table 2.14 Workability: from CKD-PC literature review 76
Table 2.15 Setting time: from CKD-PC literature review 81
Table 2.16 Hydration: from CKD-PC literature review 86
Table 2.17 Mortar compressive strength of CKD 1 at 0%, 5%, and 10% replacement of PC 3 as a function of time (Maslehuddin et al., 2008a) 89
Table 2.18 Compressive strength: from CKD-PC literature review 100
Table 2.19 Flexural and tensile strength: from CKD-PC literature review 106
Table 2.20 Soundness: from CKD-PC literature review 108
Table 2.21 Mortar drying shrinkage with 0%, 5%, and 10% CKD 1 replacement of PC 3 (Maslehuddin et al., 2008a) 110
Table 2.22 Drying shrinkage: from CKD-PC literature review 112
Table 2.23 Alkali-aggregate reactivity: from CKD-PC literature review 115
Table 2.24 Concrete resistivity and risk of reinforcement corrosion as specified in COST 509 (Maslehuddin et al., 2008b) 118
Table 2.25 Steel corrosion: from CKD-PC literature review 120
Table 2.26 Chloride permeability of PC 1 and PC 2 with CKD 1 replacement at 0%, 5%, 10%, and 15% (Maslehuddin et al., 2008b) 122
Table 2.27 Permeability: from CKD-PC literature review 123
Table 2.28 Freezing and thawing cycles: from CKD-PC literature review 125
Table 2.29 Sulfate resistance: from CKD-PC literature review 125
Table 3.1 CKD kiln process description 128
Table 4.1 Melting points and volatility of compounds in CKDs (Manias, 2004) 139
xii
Table 4.2 Chemical and select physical components of PC, CKD, and filler materials (mass %) 142
Table 4.3 Cements TI and TII mineralogical composition (mass %) 145
Table 4.4 CKD mineralogical compositions using direct test methods (mass %) 146
Table 4.5 Mineralogical composition of CKD and filler materials (mass %) 148
Table 4.6 Physical properties of all materials 152
Table 4.7 Ionic concentrations of 10:1 water to solid ratio (by mass) 159
Table 4.8 Range for chemical and physical properties of Cement TI blends at 10% and 20% replacement (Theoretical calculation, mass %) 163
Table 4.9 Range for chemical and physical properties of Cement TII blends at 10% and 20% replacement (Theoretical calculation, mass %) 164
Table 4.10 Iterative process to determine the water requirement for normal consistency of (a) Cement TI and (b) Cement TII 195
Table 4.11 Range of change in water demand for normal consistency of pastes 198
Table 4.12 Range of flow for all mortars 204
Table 4.13 Compressive strength range for CKD-PC blends as percent of PC alone 222
Table 4.14 Compressive strength range for PC-filler blends as percent of PC alone 222
Table 4.15 Autoclave expansions for (a) Cement TI and (b) Cement TII 236
Table 4.16 Range of autoclave expansions for all blends 239
Table 4.17 ASR concrete mix alkali loadings and CKD replacement levels for (a) Test Series I: Cement TI CKD blends and (b) Test Series II: Cement TII CKD blends 243
xiii
List of Figures
Figure 2.1 Cement manufacturing process (Corish and Coleman, 1995) 9
Figure 2.2 Clinker reactions in kiln feed as a function of temperature (Manias, 2004) 12
Figure 2.3 Schematic of (a) a wet and long-dry pyroprocess and (b) a preheater/precalciner pyroprocess (with a single preheater tower) (Manias, 2004) 15
Figure 2.4 Schematic of electrostatic precipitator (ESP) efficiency (Peethamparan, 2002) 19
Figure 2.5 CKD and PC particle size distribution (Peethamparan et al., 2008) 30
Figure 2.6 CKD and PC particle size distribution from published literature (Sreekrishnavilasam et al., 2006) 31
Figure 2.7 Heat evolution of PC paste during hydration stages: (1) initial reaction, (2) induction, (3) acceleration, (4) deceleration, and (5) slow continued reaction (Gartner et al., 2002) 36
Figure 2.8 Relative volumes of the major compounds in the microstructure of hydrating PC pastes as a function of time (Odler, 1998) 36
Figure 2.9 Effect of firing temperature on the heat evolution of pure free calcium oxide during hydration (Shi et al., 2002) 46
Figure 2.10 Heat of hydration of cement paste determined by isothermal conduction calorimetry, (20°C and w/c = 0.44); (a) PC (b) PC + 0.5% SO3, (c) PC + 2.5% SO3 (Lawrence, 1998b) Note: Sulfate added as Gypsum (Calcium Sulfate) 51
Figure 2.11 Optimization of gypsum additions for compressive strength at different ages (Gartner et al., 2002) (Note: this PC required higher SO3 levels than normal to obtain maximum strength) 53
Figure 2.12 Effect of calcium chloride on heat development in PC (Lerch, 1944) 56
xiv
Figure 2.13 Relationship between water demand and specific surface area of PC (Sprung et al., 1985) 59
Figure 2.14 Particle size distribution of CKD 5 and PC 7 (Wang et al., 2002) 69
Figure 2.15 Paste water/binder ratio, initial set, and final set of CKD 2 as a partial substitute of PC 4 at different levels of replacement (El-Aleem et al., 2005) 70
Figure 2.16 Mortar water/binder ratio of CKD 2 as a partial substitute of PC 4 at different levels of replacement (El-Aleem et al., 2005) 71
Figure 2.17 Mortar water/binder ratio of CKD 3 as a partial substitute of PC 5 at different levels of replacement (Al-Harthy et al., 2003) 72
Figure 2.18 Hydration of pastes showing (a) evaporable water content (%), (b) free lime content (%) (calcium oxide and calcium hydroxide), and (c) chemically combined water content, as a function of time at different percentage levels of PC 4 replacement with CKD 2 (El-Aleem et al., 2005) 83
Figure 2.19 Concrete compressive strength of CKD 1 at different replacement levels of (a) PC 1 and (b) PC 2 (Maslehuddin et al., 2008b) 88
Figure 2.20 Mortar compressive strength as a function of time at different percentage levels of CKD 2 replacement of PC 4 (El-Aleem et al., 2005) 90
Figure 2.21 Concrete compressive strengths, w/b (a) 0.70, (b) 0.60, and (c) 0.50, at different percentage levels of CKD 3 replacement of PC 5 (Al-Harthy et al., 2003) 92
Figure 2.22 Concrete drying shrinkage as a function of time at different replacement levels of PC 1 with CKD 1 (Maslehuddin et al., 2008b) 109
Figure 2.23 Concrete drying shrinkage as a function of time at two different w/b ratios with 5% CKD 12 replacement of PC 12 (Wang and Ramakrishnan, 1990) 111
Figure 2.24 Concrete specimen variation of electrical resistivity with moisture content at different percentage levels of CKD 1 replacement of (a) PC 1 and (b) PC 2 (Maslehuddin et al., 2008b) 117
xv
Figure 4.1 Process flow chart for CKD chemical composition analysis 140
Figure 4.2 Particle size distribution of PC, CKD and filler. The materials are in the direction and position of the arrow: LS, D, SLX, TII, TI, A, F, C, E, B, D* 155
Figure 4.3 Particle size distribution of PC, CKD and filler between 0.1 µm and 10 µm. The materials are in the direction of the arrow: LS, SLX, C, D, B, A, F, TII, TI, E, D* 155
Figure 4.4 CKD fineness correlation between (a) Blaine fineness and particle size distribution, and (b) percentage passing 45µm sieve and particle size distribution 156
Figure 4.5 Composition of pore solution w/b 0.5 high alkali PC paste (Gartner et al., 2002) 158
Figure 4.6 Schematic of isothermal conduction calorimetry curve heat liberation characterization 168
Figure 4.7 Cumulative heat of hydration during initial hydrolysis (Ai) of (a) Cement TI blends and (b) Cement TII blends (w/b = 0.4, 23°C) 170
Figure 4.8 Cumulative heat of hydration during initial hydrolysis (Ai) as a function of Free CaO (%) for (a) Cement TI CKD blends and (b) Cement TII CKD blends (w/b = 0.4, 23°C) 171
Figure 4.9 Cumulative heat of hydration during initial hydrolysis (Ai) as a function of (a) sulfate content for Cement TI CKD blends and (b) alkali content for Cement TII CKD blends (w/b = 0.4, 23°C) 173
Figure 4.10 Minimum heat of hydration rate during induction period (Qi) of (a) Cement TI blends and (b) Cement TII blends (w/b = 0.4, 23°C) 175
Figure 4.11 Minimum heat of hydration rate during induction period (Qi) as a function of sulfate content for (a) Cement TI CKD blends and (b) Cement TII CKD blends (w/b = 0.4, 23°C) 176
Figure 4.12 Minimum heat of hydration rate during induction period (Qi) as a function of calcium langbeinite content for (a) Cement TI CKD blends and (b) Cement TII CKD blends (w/b = 0.4, 23°C) 177
xvi
Figure 4.13 Time of minimum heat of hydration rate during the induction period (ti) of (a) Cement TI blends and (b) Cement TII blends (w/b = 0.4, 23°C) 179
Figure 4.14 Time of minimum heat of hydration rate during the induction period (ti) as a function of total alkali content for (a) Cement TI CKD blends and (b) Cement TII CKD blends (w/b = 0.4, 23°C) 180
Figure 4.15 Main hydration peak relative to the minimum peak rate heat of hydration during the induction period (Qw-Qi) for (a) Cement TI blends and (b) Cement TII blends (w/b = 0.4, 23°C) 182
Figure 4.16 Main hydration peak relative to the minimum peak rate heat of hydration during the induction period (Qw-Qi) as a function of calcium langbeinite content for (a) Cement TI CKD blends and (b) Cement TII CKD blends (w/b = 0.4, 23°C) 184
Figure 4.17 Heat of hydration for Cement TI with (a) CKD A and LS at 10% replacements, (b) CKD C and LS at 10% replacements, (c) 0% and LS at 20% replacements, and (d) CKD B and LS at 20% replacements (w/b = 0.4, 23°C) 186
Figure 4.18 Heat of hydration for Cement TI with (a) 0% and LS at 10% replacements and (b) CKD E and LS at 20% replacements (w/b = 0.4, 23°C) 188
Figure 4.19 Heat of hydration for Cement TII with (a) 0% and LS at 10% replacements, (b) CKD C and LS at 10% replacements, and (c) CKD C and LS at 20% replacements (w/b = 0.4, 23°C) 189
Figure 4.20 The total heat generation from induction period to 7 days hydration (A7d-Ai) for (a) Cement TI blends and (b) Cement TII blends (w/b = 0.4, 23°C) 191
Figure 4.21 Water requirement for normal consistency of (a) Cement TI blends and (b) Cement TII blends 197
Figure 4.22 Correlation between Cement TI and Cement TII blends with the same CKD and replacement level for (a) all CKDs and (b) CKDs A, B, C, and D 199
xvii
Figure 4.23 Water requirement for normal consistency as a function of free lime content for (a) Cement TI CKD blends and (b) Cement TII CKD blends 200
Figure 4.24 Mortar flow of (a) Cement TI blends and (b) Cement TII blends 203
Figure 4.25 Mortar flow as a function of free lime content for (a) Cement TI CKD blends and (b) Cement TII CKD blends 206
Figure 4.26 Mortar flow as a function of (a) percentage of volume less than 30.5 µm for Cement TI CKD blends (excluding CKDs E and F) (b) percentage passing 45 µm for Cement TII blends (excluding CKDs E and F) 207
Figure 4.27 Initial set time for (a) Cement TI blends and (b) Cement TII blends 211
Figure 4.28 Initial set time as a function of the time of minimum heat rate during the induction period (ti) for (a) Cement TI CKD blends (excluding circled data points) and (b) Cement TII CKD blends 214
Figure 4.29 Initial set time as a function of soluble alkali content for (a) Cement TI blends (excluding circled data points) and (b) Cement TII blends 216
Figure 4.30 Mortar compressive strength of Cement TI blends at 1, 3, 7, 28, and 90 days (w/b = 0.485) for (a) 10% replacement and (b) 20% replacement (w/b = 0.485) 220
Figure 4.31 Mortar compressive strength of Cement TI blends at 1, 3, 7, 28, and 90 days (w/b = 0.485) for (a) 10% replacement and (b) 20% replacement (w/b = 0.485) 221
Figure 4.32 Mortar compressive strength as a function of total sulfate content for Cement TI CKD blends at (a) 1 day and (b) 3 days (w/b = 0.485) 224
Figure 4.33 Mortar compressive strength as a function of total sulfate content for Cement TII CKD blends at (a) 1 day and (b) 3 days (w/b = 0.485) 226
Figure 4.34 Mortar compressive strength at 28 days as a function of percentage passing 45 µm for Cement TI CKD blends 228
xviii
Figure 4.35 Mortar compressive strength at 28 days as a function of calcite for Cement TII CKD blends (w/b = 0.485) 228
Figure 4.36 Expansion in limewater after 14 days for (a) Cement TI blends and (b) Cement TII blends 233
Figure 4.37 Expansion in limewater at 14 days as a function of sulfate content for (a) Cement TI CKD blends and (b) Cement TII CKD blends 234
Figure 4.38 Autoclave Expansions for (a) Cement TI blends and (b) Cement TII blends 238
Figure 4.39 Autoclave expansion as a function of free lime content (excluding data points in the circles) for (a) Cement TI CKD blends and (b) Cement TII CKD blends 240
Figure 4.40 ASR expansions over 2 years for (a) Test Series I: Cement TI CKD blends and (b) Test Series II: Cement TII CKD blends 245
xix
List of Appendices
Appendix A. CKD Chemical Composition Correction Calculations
Appendix B. PC and CKD TGA Analysis
Appendix C. CKD XRD Scans
Appendix D. PC, CKD-PC, and PC-Filler Properties
Appendix E. Isothermal Conduction Calorimetry Results
Appendix F. Mortar Flow Statistical Analysis
Appendix G. Mortar Compressive Strength Statistical Analysis
Appendix H. Mortar Expansion in Limewater Statistical Analysis
xx
List of Notation
The following notations are commonly used throughout this thesis: General
AAR Alkali-Aggregate Reaction
AASHTO American Association of State and Highway Transportation
Officials
ANOVA Analysis of Variance
ASR Alkali-Silica Reaction
ASTM American Society for Testing Materials
BS British Standard
CKD Cement Kiln Dust
CSA Canadian Standards Association
EPA Environmental Protection Agency (U.S.)
ESP Electrostatic Precipitators
GHG Greenhouse Gas
ISAT Initial Surface Absorption Test
LOI Loss on Ignition
NCHRP National Cooperative Highway Research Program
PC Portland Cement
PCA Portland Cement Association
PSD Particle Size Distribution
SCM Supplementary Cementitious Material
TCLP Toxicity Characteristic Leaching Procedure
TGA Thermal Gravimetric Analysis
XRD X-ray Diffraction
xxi
Chemical
AFm Aluminate-Ferrite-Monosubstituted, Monosulphoaluminate, or
Monosulphate
AFt Aluminate-Ferrite-Trisubstituted or Ettringite
C3S Tricalcium Silicate or Alite
C2S Dicalcium Silicate or Belite
C3A Tricalcium Aluminate or Aluminate
C4AF Tetracalcium Aluminate Ferrite or Ferrite
CH Calcium Hydroxide
C-S-H Calcium Silicate Hydrate
Na2Oe Equivalent Na2O (Na2O + 0.658 K2O) (mass %)
1
1.0 INTRODUCTION
1.1 Background
There are currently many challenges to the utilization of by-product cement kiln dusts
(CKDs) as partial replacement of Portland cement (PC). CKDs are fine powders (CKDs
typically have between 80 and 90% passing a 90 µm sieve) that are generated during the
cement manufacturing process, then carried off in the flue gases, and subsequently
collected in baghouses or electrostatic precipitators. The portion of CKDs that are not
returned back to the cement manufacture process, or otherwise used beneficially, are
placed in stockpiles or landfills. A limited number of studies have shown that CKDs
removed from the cement manufacturing process could be used as partial replacements of
PC in the range of 5 – 15%, by mass. Although standards allow for the use of CKDs at
low levels of PC replacement, very little is known about the effects of different CKDs in
pastes, mortars, and concrete. The studies that have been published on the use of CKDs
as a partial substitute of PC often report conflicting results.
Significant amounts of CKDs are placed in landfills every year. In 2000, the Portland
Cement Association (PCA) conducted a United States (U.S.) Cement Industry survey of
92 cement plants. They reported total clinker production to be 68.8 million tonnes
(clinker is the major component of PC and is typically 90 – 95% of total cement
production). The amount of CKDs removed from the cement kiln process that year for
the same 92 cement plants was 2.8 million tonnes (4.1% of clinker production). Almost
80% of the CKDs removed from cement-producing kilns were placed in landfills, while
only approximately 20% were beneficially re-used (Hawkins et al., 2004). On a global
scale, it is estimated that approximately 30 million tonnes of CKDs are removed from the
cement manufacturing process every year (Dyer et al., 1999). Approximately 25 years
ago, the CKDs in U.S. landfills were estimated to be greater than 90 million tonnes
(Collins and Emery, 1983).
2
There are many applications of CKDs that continue to be investigated: for example, as a
component in cements and masonry products, as an agricultural/soil fertilizer, as a soil
stabilizer, as a wastewater stabilizer, as a partial replacement of soda in glass production,
as an anti-stripping agent in asphalts, and as a subgrade for highway construction (Bhatty,
1995). From the perspective of the cement industry, however, the most desirable
application of CKDs that cannot be recycled back into the process is their use as a partial
replacement of PC.
1.2 Problem Statement
Four obstacles related to CKD compositions currently inhibit their use in concrete: (i)
inadequate CKD characterization, (ii) potentially deleterious interactions between CKD
and PC, (iii) unknown interactions of CKD with mineral and/or chemical admixtures, and
(iv) CKD-PC conformance to cement and concrete standards. The focus of the thesis is to
mainly address the first and second categories. Each category is briefly discussed in this
section, however, to provide the reader with a broader understanding of the problem.
In order to understand the effects of CKDs in concrete, it is essential to have a proper
characterization of an individual CKD. Comprehensive compositional analysis of a CKD
is also important for optimization of a CKD-PC blend for use in concrete field
applications. Determining the characteristics of the CKDs used in previous CKD-PC
interaction studies was not always possible due to the incomplete compositional analysis
provided. This is likely due to the insufficient and sometimes inappropriate application of
compositional analysis procedures designed for PC to determine the composition of
CKD. CKD is a unique material that has different characteristics from PC. In comparison
to PC, CKDs typically contain higher concentrations of free lime, alkalis, sulfates,
chlorides, raw materials, and trace heavy metals (Hawkins et al., 2004).
3
CKDs can influence the interactions among the basic components of concrete (PC, water,
and aggregate). The effects of the individual components found in CKDs at elevated
concentrations in concrete are generally understood. The varying concentrations of these
components in combination with each other as found in CKDs, however, are not well
understood. Therefore, it is not clear how a particular CKD will interact as a partial
replacement of a given PC. The composition of each PC can also have unique
characteristics. A given CKD may react differently with dissimilar PCs and, therefore,
result in different effects on concrete properties. It is important to understand how the
CKD-PC interaction will impact concrete properties such as workability, hydration,
setting time, strength, volume stability, and durability for optimization of a mix design in
the field.
The impact of a CKD in concrete is not limited to its interaction with PC, aggregate, and
water. The use of supplementary cementing materials (SCMs) in concrete has been
steadily increasing over the years. The presence of a CKD could influence the
mechanisms and effectiveness of SCMs and chemical admixtures in concrete. SCMs such
as slag, fly ash, and silica fume contribute to the properties of the hardened concrete
through hydraulic and/or pozzolanic action (pozzolanic action occurs when a pozzolan
combines with calcium hydroxide to exhibit cementitious properties). It has been reported
that the high alkali and sulfate content of a CKD can act as an excellent activator for
pozzolanic materials (Konsta-Gdoutos and Shah, 2003).
Chemical admixtures are also commonly used in concrete mixtures. Chemical admixtures
can be defined as materials other than water, aggregates, and hydraulic cement that are
added immediately before or during mixing of concrete. The most prominent chemical
admixtures are used to decrease the quantity of water needed to obtain a given degree of
workability or to entrain air in order to increase the resistance of concrete to damage from
freezing (Taylor, 1997). Chemical admixtures can also be used to increase workability by
dispersion of cement in the aqueous phase of concrete and to accelerate or retard the
4
normal rate of hydration (Dodson, 1990). There is little, if any, published research on the
interaction of CKDs and PC with chemical admixtures.
Cement and concrete standards include limitations on the chloride, sulfate, and alkali
content in PC and concrete to ensure acceptable performance and durability. If it is
shown that the elevated concentrations of these components in CKDs do not compromise
performance and durability in concrete, regulatory standards may need to be modified to
allow for increased amounts of their replacement of PC. In order to allow for the use of
industrial by-products such as CKDs, there is a move away from prescriptive or
compositional standards towards performance standards. ASTM C150 allows the use of
processing additions meeting the requirements of ASTM C465 for use in the manufacture
of hydraulic cements.
1.3 Incentives and Objectives of This Study
The use of CKDs as a partial replacement of cement has the potential to substantially
reduce the environmental impact of CKD disposal and create significant cost and energy
savings to the cement industry. From an environmental perspective, CKD removal from
the cement manufacturing process leads to excessive generation of gas emissions and
increased need for land disposal sites. Partial substitution of PC with CKDs would
decrease the need for clinker production and reduce the amount of energy wasted due to
partial pyropressing of CKDs. A reduction of clinker production would also reduce
greenhouse gases that are related to fuel burning and limestone decarbonation. As
environmental concerns increase, it is also important to recognize that obtaining landfill
permits is becoming increasingly difficult. The use of CKDs as a partial replacement of
cement could help minimize the size and number of landfill disposal sites.
In addition to the environmental benefits related to CKD-PC blends, reducing the clinker
factor in cement would also create several financial benefits. First, the lifespan of the
limestone quarry and other natural resources would increase. Second, the reduction of
5
raw materials required for PC production would reduce material costs and energy
consumption related to mining, crushing, and grinding. Third, a reduction of clinker
production would reduce pyroprocess, dust collection, and landfill disposal costs. Fourth,
since the CKD is already a fine powder, there will be less energy consumption in the
finish mill to achieve the target fineness compared to the energy needed to interground
clinker. Finally, the typical transport costs for other materials used for blend cements
would not be incurred since CKD is generated on the same site as the PC. It is important
to acknowledge that the cement and concrete industry may need to incur costs related to
building and maintaining systems that allow for blending of CKD with cements that meet
quality control targets.
The study of CKD as a partial replacement of PC has been a sporadic research area for
the past 30 years. The concrete industry has been very successful in utilizing other
industrial by-products – such as slag, fly ash, and silica fume – as partial replacements of
PC. Once considered to be waste products, these SCMs are now widely used to improve
the workability, strength, and durability characteristics of concrete. Although there are
many studies that report the effects of different binary and ternary blends of CKDs with
PC, silica fume, fly ash, and/or slag, it is very difficult to make conclusions regarding
performance due to conflicting results and incomplete CKD characterizations. The
reasons for the different effects of CKD-PC blends have not been thoroughly explored.
The interaction between different CKDs and PC must be well understood before
introducing chemical admixtures and other SCMs. Understanding the CKD-PC
interactions and developing appropriate limits for specific deleterious components could
ultimately allow for the standardization and optimization of blended cements with high
replacement levels (5 – 15%, by mass) of PC with CKD in concrete, leading to both
environmental and economic benefits.
6
The first objective of this study was to compare the chemical, physical, mineralogical,
and rapid ion dissolution properties of different CKDs with PC. Since there is a lack of
proper CKD characterization in previous CKD-PC blend research, the present study aims
to identify the appropriate chemical and physical analytical methods that should be used
for CKD composition analysis. Mineralogical composition analysis is a fine complement
to chemical composition analysis since the effects of CKD elements in a CKD-PC blend
may vary depending upon the form in which they actually exist. Therefore, a method to
quantify the relative abundance of the different mineralogical phases within CKDs was
introduced. Since the availability of ions in the liquid phase greatly influences PC
hydration, the rapid ion dissolutions from CKDs compared to PC were also investigated.
The second objective was to utilize the material characterization analysis to determine the
relationships among the composition properties of CKD-PC blends and their effects on
hydration, mechanical properties, and volume stability. Paste and mortar tests were used
to assess the effects of CKDs on: (i) heat of hydration, (ii) water demand, (iii) flow, (iv)
initial setting time, (v) compressive strength, (vi) expansion in limewater, and (vii)
autoclave expansion. Regression analysis was performed where possible to examine the
relationships among CKD-PC blend properties and various independent variables.
Additionally, concrete prisms were used to evaluate the impact of CKDs on a key
durability concern – alkali silica reactivity (ASR).
1.4 Summary of Chapters
The topics addressed in this study are presented in eight chapters. A brief summary of
Chapters 2 to 8 is given below.
Chapter 2 is a literature review that provides an understanding of CKD manufacture and
management; a basic understanding of CKD composition and its variability relative to
PC; a review of PC hydration and the known effects of the individual components of
CKDs in pastes, mortars, and concrete; and a review of previous studies on CKD-PC
7
interaction. All performance parameters in previous CKD-PC blend studies are presented
in order to provide a general overview of the subject, although some aspects are not part
of the current study.
Chapter 3 describes the materials and test methods used in the current study. The CKDs
selected for this study are representative of those available in North America. Various test
methods related to material characterization and CKD-PC performance used for the
experimental program are described.
Chapter 4 presents the results and discussions of the current study. The first part of this
chapter explores the material characterization and analytical methods used to determine
accurate CKD characterizations. The second part of this chapter focuses on the effects
and relationships of using CKDs as a partial replacement of PC on heat of hydration,
workability, setting time, compressive strength, expansion in limewater, and soundness.
Additionally, it also discusses the impact of CKDs on ASR.
Chapter 5 highlights the main contributions of the thesis, giving a thorough explanation
of the value of the research that was conducted. In Chapter 6 the conclusions of the
thesis are presented.
Chapter 7 provides recommendations for future research that will enhance the use of
CKDs in concrete. This research study is a first step towards a comprehensive
understanding of how CKD-PC blends can be optimized.
Chapter 8 provides the list of the references that were consulted in the process of research
for the thesis.
8
2.0 LITERATURE REVIEW
2.1 CKD Manufacture and Management
2.1.1 Portland Cement Manufacture Overview
A critical examination of CKD utilization as a partial replacement of PC cannot be
conducted without an understanding of basic cement manufacturing. The composition
and variability of a CKD produced at a plant is directly related to the cement
manufacturing process at that plant. PC is produced by burning ground mixtures of
limestone and other materials up to high temperatures (greater than 1450˚C) in a rotary
kiln to form clinker (Manias, 2004). The clinker is cooled and then ground in a finish mill
along with a small amount of gypsum to make a gray powder called PC. ASTM C219
defines PC as “a hydraulic cement produced by pulverizing Portland-cement clinker, and
usually containing calcium sulfate”. Low levels of mineral additives such as limestone,
however, are increasingly common in PC. Clinker consists of predominantly crystalline
calcium silicates. Hydraulic means that it sets and hardens by chemical interaction with
water. Although every plant has significant differences in equipment design and
operation, the chemical and physical transformation of raw materials into PC is
essentially the same at all cement plants. The basic steps of cement manufacturing are
illustrated in Figure 2.1.
The principal raw mix components that are required for the production of clinker are
calcium, silica, aluminum, and iron (Taylor, 1997). Calcium carbonate and argillaceous
substances (clay) are naturally occurring raw materials that typically contain the principal
chemical elements. Limestone, the most common form of calcium carbonate, is the usual
calcium source for cement manufacturing. Other forms of calcium carbonate such as
chalk, shell deposits, and calcareous muds can also be used. Clays are essentially hydrous
aluminum silicates with complete or partial substitution of magnesium and/or iron in
9
place of aluminum in certain minerals. Alkalis or alkaline earths are also present as
essential constituents in clays (Chatterjee, 2004). The natural raw materials are
traditionally mined at quarries close to the cement plant. At times, auxiliary raw materials
that contain iron, alumina, and/or silica are required in order to achieve the proper raw
mix proportion. Blast furnace slag, fly ash, iron oxide, bauxite, and spent catalysts are
widely used auxiliary raw materials (Bhatty and Gajda, 2004).
Figure 2.1 Cement manufacturing process (Corish and Coleman, 1995)
A finely ground mixture typically consisting of approximately 75% calcium carbonate,
15% silicon dioxide, 3% aluminum oxide, and 2% iron oxide provides the major
components in the raw materials. The raw materials also contain a certain amount of
volatiles (less then 5% by mass). Some of these volatiles are alkalis (potassium oxide and
sodium oxide), sulfur, and chloride (Taylor, 1997). In addition to the major elements
10
which make up cement, smaller concentrations of almost every other element will be
present in the raw materials. Magnesium, titanium, manganese, and phosphorous are
common but they are minimized to prevent potentially deleterious effects on cement
burning and quality. Minor trace metals can also be present in the raw materials but are
also kept at low levels to avoid adverse effects (Bhatty, 2004).
In an open quarry, limestone mining operations begin with removal of overburden (waste
rock) by bulldozers to expose the top surface of the limestone. Drills are used to create
deep holes close to the open face of the limestone quarry for dynamite placement. The
limestone rock is then blasted with the dynamite to reduce its maximum diameter to
between approximately 1 and 2 metres. Front-end loaders load the blast rock into trucks
or railroad cars to be sent to the crushing system. The primary and secondary crushing
systems reduce the limestone size to between approximately 10 mm and 50 mm in
diameter (Chatterjee, 2004).
The crushed limestone and other raw materials are fed into a grinding mill to obtain the
correct size and composition for the raw mix. In the wet process, the raw materials are
mixed with approximately 30 – 40% water during grinding to form a slurry. The
composition of earth minerals in limestone and clays can be quite variable and may
require substantial blending and analysis to maintain a homogenous mixture.
Homogeneity of the raw mix is essential for quality control and plant efficiency. The wet
process homogenization system utilizes mechanical and/or pneumatic systems to agitate,
blend, and store the homogenized raw mix in cylindrical tanks or basins until it is fed into
the pyroprocessing system. The most common homogenization system used for dry
process cement plants over the past several decades is the pneumatic system based on the
air fluidization method. The homogenized raw mix is commonly referred to as kiln feed
(Chatterjee, 2004).
11
The pyroprocess is the focal point of the cement manufacturing process. Rotary kilns are
long, cylindrical, and slightly inclined (3 – 4%) furnaces that are lined with refractory
bricks to protect the steel shell and retain heat within the kiln (Manias, 2004). The kiln
feed is fed into the upper end of the kiln that rotates on its longitudinal axis. The fuels for
the kiln are burned at the lower end of the kiln. As the kiln feed enters the pyroprocess
the materials are gradually heated to form calcium oxide, which combines with silicon
dioxide at temperatures exceeding 1400oC in the kiln. Alumina and iron act as fluxing
agents, lowering the reaction temperature of the mix to a practical firing temperature.
Although there are many different kiln system designs, all kiln feed undergoes the same
reactions during the pyroprocess to form clinker – the hard pellets that typically range in
size from 0.3 to 5.1 cm in diameter. The chemical and physical transformations of the
kiln feed to clinker are quite complex, but can be viewed conceptually as the sequential
events listed in Table 2.1 (Manias, 2004).
The four major compounds of clinker that constitute approximately 95% of the clinker,
by mass are: tricalcium silicate (C3S) (35 – 65%), dicalcium silicate (C2S) (10 – 40%),
tricalcium aluminate (C3A) (0 – 15%), and tetracalcium aluminoferrite (C4AF) (5 – 15%)
(Taylor, 1997). C3S and C2S are commonly referred to as alite (impure C3S) and belite
(impure C2S), respectively. Alite typically contains 3 – 4% of substituent oxides, the most
significant of which are Fe2O3, MgO, and Al2O3. Belite may contain 4 – 6% of
substituent oxides of which Al2O3 and Fe2O3 are most common (Taylor, 1997). Alite and
belite constitute about 65 – 75% of PC and the combined total content of the four
principal clinker compounds in PC is approximately 85%. Cement chemistry
nomenclature abbreviations are as follows: C = CaO, S = SiO2, A=Al2O3, and F=Fe2O3.
Several other compounds – such as alkali sulfate and calcium oxide – are present in
minor amounts. Figure 2.2 shows the phase transformation of kiln feed to clinker at
different stages within the pyroprocess (Manias, 2004).
12
Table 2.1 Kiln material transformations (Manias, 2004)
Temperature, ˚C Material Transformation
100 Evaporation of free water
100-300 Removal of adsorbed water in clay materials
450-900 Removal of chemically bound water
700-850 Calcination of carbonate materials
800-1250 Formation of belite (C2S), aluminates, and ferrites
>1250 Formation of liquid phase melt
1330-1450 Formation of alite (C3S)
1300-1240 Cooling of clinker to solidify liquid phase
1250-100 Clinker cooled in cooler
Figure 2.2 Clinker reactions in kiln feed as a function of temperature (Manias, 2004)
13
The pyroprocess is the most energy intensive component of the overall manufacturing
process. The most commonly used fuels are coal, natural gas, and oil. Coal can contain
significant quantities of sulfur, trace metals, and other halogens that can influence the
clinker composition as well as kiln operation dynamics. Natural gas and oil typically
contain less sulfur for an equal amount of calorific energy. The use of supplemental fuels
– such as petroleum coke, used tires, impregnated sawdust, waste oils, lubricants, sewage
sludge, metal cutting fluids, and waste solvents – has expanded in recent years. Minor
trace elements from these supplemental fuels can influence clinker composition and kiln
performance (Greco et al., 2004).
The pyroprocess at each cement plant can differ substantially depending on the state of
technological advancement and the raw materials used. The three major types of kiln
pyroprocessing for cement manufacturing in North America are: wet, long-dry, and
preheater/precalciner. The main kiln design, production, and energy consumption
characteristics for each process are provided in Table 2.2. An important common aspect
of different cement pyroprocesses is the presence of the burning zone where the flame
temperatures exceeds 1400oC (Manias, 2004).
Table 2.2 Summary of operation data on different kiln systems (Manias, 2004)
Kiln Systems rpm tpd/m3 Length/Diameter
Specific Fuel Consumption,
kcal/kg kWh/t
Residence Time
minutes
Wet 1 0.45-0.8 30-35 1300-1650 17-25 180-240
Long-dry 1 0.5-0.8 30-35 1100-1300 20-30 180-240
Preheater 2 1.5-2.2 14-16 750-900 25 30-40
Precalciner 3.6 3.5-5.0 10-14 720-850 25 20-30
rpm: revolutions per minute
tpd/m3: clinker produced in tonnes per day cubic metre
kWh/t: electric energy consumed in kilowatt hour per tonne of clinker
14
In the wet and long-dry processes the entire pyroprocess occurs in the kiln, as shown in
Figure 2.3(a). In the wet process the raw materials are introduced to the kiln as slurry
containing 30 – 40% water, which results in a relatively high energy consumption (El-
Sayed et al., 1991). The kiln usually has a system of chains near the feed end of the kiln
to improve heat transfer from hot gases to the solid materials. Kiln rotation allows the
chains to be exposed to the hot gases, and they transfer heat to the cooler materials at the
bottom of the kiln. The long-dry kiln process is a newer technology than the wet process;
while both processes are similar, the long-dry kiln feed is dry. The long-dry kiln process
is the most widely used process for clinker production today and is more energy efficient
than the wet process (Manias, 2004).
Due to higher energy prices and improved technology, the design of long-dry kiln
systems has evolved into a process consisting of a preheater with a number of cyclone
stages (five or, in modern kiln systems, even six) to promote heat exchange between the
hot kiln exit gases at 1000°C and the incoming dry kiln feed, as shown in Figure 2.3(b).
Calcination (decarbonation) is the decomposition of calcium carbonate to free calcium
oxide. The material entering the rotary kiln section is already at around 800°C and partly
calcined (20 – 30%) with some of the clinker phases already present. The improved heat
transfer allows the length of the kiln to be reduced, relative to the length of kilns in the
wet and long-dry kiln processes. In recent decades, the precalcination technology has also
been introduced as an energy saving measure and is a modification of the preheater
process. In the precalciner process, the combustion air for burning fuel in the preheater no
longer passes through the kiln, but is taken from the cooler region by a special tertiary air
duct to a specially designed combustion vessel in the preheater tower. Typically, 60% of
the total fuel is burnt in the calciner, and the kiln feed is more than 90% decarbonated
before it reaches the rotary kiln section allowing for increased efficiency (Manias, 2004).
15
(a)
(b)
Figure 2.3 Schematic of (a) a wet and long-dry pyroprocess and (b) a
preheater/precalciner pyroprocess (with a single preheater tower) (Manias, 2004)
16
The final component of all pyroprocess systems is the clinker cooler. The most common
types of clinker coolers are rotary, planetary, and reciprocating grate. The clinker is
cooled from approximately 1250°C to 100°C by ambient air. The air passes through the
bed of clinker and then passes into the kiln for use as combustion air. Clinker that is
cooled rapidly typically results in a higher quality clinker (Peray, 1986).
The last step of PC manufacturing is the blending and grinding of clinker and up to 5% –
6% calcium sulfate in a ball or tube mill (finish mill). Calcium sulfate, typically in the
form of gypsum and/or natural anhydrite, is generally acquired from a source external to
the cement plant. The finish mill reduces the size of the clinker and calcium sulfate to a
maximum diameter of 100 micrometers and consumes a large portion of the electric
energy in the cement manufacturing process (30 to 50 kWh/ton of cement). The total
electric energy consumption to make PC is between 110 and 130 kWh/ton of cement.
(Hawkins et al., 2004).
CKDs are removed from the pyroprocess mostly for quality control and/or stable
operation of the kiln (CKD removal from the pyroprocess is discussed in further detail in
the following section). The U.S. cement plant average rate of CKD removal from the
manufacturing process has been reported to be 11.5% of clinker production for wet kilns,
10.5% of clinker production for long-dry kilns, and 4.0% of clinker production for
preheater/precalciner kilns (EPA, 1993). It appears that the development of
preheater/precalciner systems has resulted in significantly lower amounts of CKDs
removed from the pyroprocess per tonne of clinker relative to the wet and long-dry kiln
processes.
17
2.1.2 CKD Generation
CKDs are a fine by-product of the PC rotary kiln production operation that is captured in
the air pollution control dust collection system. As kiln feed travels through the kiln, the
finest particles of the raw materials, partially processed feed, and components of the final
product are entrained in the combustion gases flowing countercurrent to the feed. The
particulates and combustion gas precipitates that are removed from the gas stream by air
pollution dust collection systems are collectively referred to as CKD (Hawkins et al.,
2004).
Many cement plants return all or a portion of the CKD from the dust collection system to
the pyroprocess with kiln feed or at mid-kiln with dust scoops. The most desirable
application of CKDs is to introduce as much as possible back into the clinker production
cycle. The CKDs that are not returned as a pyroprocess input or otherwise used
beneficially are placed in landfills (Hawkins et al., 2004). Although it is difficult to
quantify a direct correlation between dust generation and plant operation, the amount of
CKD generated strongly depends upon the type of process and design of gas velocities in
the kiln. Other factors include kiln feed composition, fuel composition, kiln operation,
and type of dust collection system (Bhatty, 1995).
The raw materials and fuel inputs can have a significant impact on the chemical
composition and amount of CKD removed from the pyroprocess. If the raw material
and/or fuel inputs contain substantial amounts of volatiles (sodium, potassium, chloride,
and/or sulfur), a higher quantity of CKD will likely be generated in the pyroprocess.
These elements partially or completely volatilize in the sintering/burning zone close to
the flame and are collected in the gas stream flowing counter-current to kiln feed
(Hawkins et. al., 2004). Some of the volatile compounds cannot readily exit the
pyroprocess with the gas stream because they condense in the cooler parts of the system.
As volatile compounds pass through the melting, vapourizing, and condensing cycle,
their concentration in the pyroprocess can increase to the point where they can be
18
catalysts for undesirable coating buildup and ring formation in the kiln. The melting
points and relative volatilities of common kiln volatile compounds are shown in Table
2.3. Materials that volatilize in the burning zone will tend to accumulate onto the surfaces
of smaller particles of kiln feed in the cooler parts of the pyroprocess or remain in the gas
stream and be collected in the dust collectors as a CKD (Manias, 2004).
Table 2.3 Melting points and relative volatiles of different compounds in the kiln burning
zone (Manias, 2004)
Volatile Compounds Melting Point, ˚C Range of volatility*, %
CaCl2 772 60 to 80
KCl 776 60 to 80
NaCl 801 50 to 60
Na2SO4 884 35 to 50
K2SO4 1069 40 to 60
CaSO4 1280 ---
*Range of volatility: % of compound that will volatilize at melting point
The location at which a CKD is extracted from the pyroprocess also has an impact on its
characteristics. For example, preheater and precalciner kilns typically extract the CKDs
with an alkali/chloride bypass system that is located between the preheater tower and the
kiln feed end of the rotary kiln. The temperatures in this region are very different from
the temperatures that CKDs are exposed to in the wet and long-dry kiln processes and
this gives it unique characteristics. In the bypass system, a portion of the kiln exit gas
stream is removed and quickly cooled by air or water to condense the volatiles to fine
particles (Manias, 2004).
19
The CKD particles in the kiln exit gas stream of all pyroprocess are removed by dust
collection systems. Common kiln dust collection systems include electrostatic
precipitators (ESPs), baghouses, and cyclones. Kiln processes equipped with ESPs
separate the CKD in multiple electric fields as illustrated in Figure 2.4. The CKD
collected in the subsequent fields are generally smaller in size and tend to have higher
concentrations of volatiles than the coarser CKD particles. Therefore, it is possible to
return the less volatile CKD from the first fields to the pyroprocess and remove the more
volatile CKD in the last fields. Baghouses and cyclones do not allow for segregation of
CKD based upon volatile concentration.
Figure 2.4 Schematic of electrostatic precipitator (ESP) efficiency (Peethamparan, 2002)
20
There are three major reasons for removal of CKD from the pyroprocess (Kessler, 1995).
First, clinker quality must be maintained. For example, the level of alkalis, chlorides,
and/or sulfates in the raw materials may be higher than the quality control targets and,
therefore, a portion of CKD would need to be removed to reduce the concentration of
volatiles. Second, a portion of CKD may need to be removed to maintain stability of the
kiln process. As previously discussed in this section, volatiles at high concentrations in
the kiln can cause severe material build-up. This can lead to challenging operational
problems such as instability, production loss, and blockage, even to the point where the
kiln must be shut down (Peray, 1986). The third major reason for removal of CKD from
the pyroprocess is due to the lack of a mechanism to return the CKD to the kiln. This is
more prevalent in wet process cement plants that were designed and built when the
manufacturing challenges and costs associated with recycling CKD back to the kiln from
the dust collection system were greater than the costs of removing CKD from the
pyroprocess and placing it in landfills.
2.1.3 Fresh and Landfill CKD
Fresh CKDs are generally difficult to handle because of their fine, dry, powdery nature
and caustic characteristics. The addition of water to mitigate blowing and dusting
problems during transport of fresh CKDs to landfills is common. Adding water at this
stage can cause hydration of the free lime and significantly reduce possible cementitious
potential for other applications. CKD landfills normally represent many years of cement
production. They are usually found in very large above-ground stockpiles or backfill
quarries. The surface of the landfill site typically crusts over and becomes hard while the
interior of the pile can stay relatively loose. Some of the interior material can remain
unhydrated, even after many years, if exposure to moisture is limited. CKD landfills are
usually located relatively close to the cement manufacturing plants and vary in age and
composition. Exposure to the elements (moisture in particular) reduces the chemical
reactivity of the kiln dusts thereby making landfill CKD composition very different from
that of fresh CKD.
21
Fresh CKD and landfill CKD should be assessed independently for their potential use as
a partial replacement of PC. Changes in composition can occur when CKDs are subject to
weather conditions and compaction procedures. In addition to converting lime to calcium
hydroxide, exposure to the natural environment could also decompose calcium
langbeinite into syngenite and gypsum. The particle size of a CKD can also change due to
hydration and compaction. These changes could have large effects on the hydration of a
CKD-PC blend.
There are large amounts of CKDs in stockpiles and landfills that are a potential source for
CKD applications. The process of utilizing landfill CKDs, however, can be very
challenging. Landfill CKDs will often harden and require crushing and screening
equipment to remove over-sized pieces as well as any waste that may have become
combined with the CKDs.
2.1.4 CKD Applications: Cement Industry Perspective
The cement industry has a keen interest in finding practical applications for CKDs in
order to reduce costs and environmental concerns related to managing their removal from
the pyroprocess. ASTM D5050 lists several beneficial applications of CKD that include:
soil fertilization, soil stabilization, raw material for glass manufacture, sewage and
wastewater treatment, and waste pollution control.
Although there have been significant developments in the use of CKDs, large amounts
continue to be placed in landfills each year. Researchers continue to investigate the use of
CKDs in several fields. In particular, the use of CKDs as a partial replacement of
traditional construction materials continues to be an area of active interest. A number of
researchers have investigated the use of CKDs for subgrade consolidation for highway
construction, cement and masonry products, contaminated soil and sludge stabilization,
and partial replacement of asphalt. Most of the previous research on CKD applications
22
has been conducted using fresh CKDs while the issue of using CKDs from landfills and
stockpiles has not been explored in great detail (Sreekrishnavilasam et al., 2006).
From the perspective of the cement industry, the most beneficial utilization of CKDs that
are removed from the pyroprocess is as partial replacement of PC. ASTM currently
authorizes the use of processing additions, including CKDs, as a partial replacement of
PC provided that the blend complies with the requirements of ASTM C150 and ASTM
C465. The American Association of State Highway and Transportation Officials
(AASHTO) limits the amount of processing addition to 1% of the total blend. Canadian
Standards Association (CSA) has similar standards as ASTM, but if the processing
addition is above 1% of the total blend, the nature and amount of processing addition in
the finished product must be provided. At the time of writing this thesis, the National
Cooperative Highway Research Program (NCHRP) 18-11 “Improved Specifications and
Protocols for Acceptance Tests on Processing Additions in Cement Manufacturing” is
preparing a report recommending that up to 5% of a processing addition can be used as a
partial replacement of PC provided that the blend complies with the requirements of
ASTM C150 and ASTM C465. (CKDs are one of the processing addition materials
assessed as part of the NCHRP study.)
2.1.5 Costs Associated with CKD Disposal
The typical costs associated with CKD disposal in the U.S. in 1995 are presented in Table
2.4. The average cost for CKD disposal, adjusting for inflation increases over 13 years at
approximately 2.62% per year and converting short tons to tonnes, is $21.60/tonne in
2008 U.S. Dollars. The average annual clinker production of a cement plant in the U.S. is
approximately 800,000 tonnes. As an example, the cost of CKD disposal for a U.S. long-
dry kiln that produces 800,000 tonnes of clinker and removes CKD at 10.5% of clinker
production in 2008 is approximately $1.8 million dollars per year. The cost to manage
CKD disposal for a Canadian cement plant under the same conditions is comparable.
23
Table 2.4 Typical costs associated with CKD disposal, $/tonne (Kessler, 1995)
Items Low Average High
Raw Material Costs $1.50 $4.00 $5.50
Kiln Feed Costs: Crushing, Conveying, Drying, and Grinding $3.00 $4.50 $6.00
Kiln Fuel Costs: Dust Calcination and Sensible Heat $1.00 $1.50 $2.00
CKD Transport: Conveying, Hauling, and Dedusting $0.50 $1.00 $1.50
Landfill Maintenance: Monitoring, Pile Maintenance, and Closing $1.00 $3.00 $5.00
Total $7.00 $14.00 $20.00
2.1.6 CKD Environmental Considerations
The United States Environmental Protection Agency (EPA) has conducted extensive
studies on the issues of production of fresh CKDs and management of stockpile and
landfill CKDs. Fugitive dust emissions, surface water pollution, and groundwater
pollution have been addressed in these studies. In recent years, hazardous waste has been
used as a fuel in cement kiln operations. The use of waste materials in cement kiln
operations has raised concerns regarding the accumulation of heavy metals in CKD
generated by plants that use these alternative materials.
The EPA (1993) has classified CKDs as a non-hazardous material under the Bevill’s
Amendment; however, it also stated that the runoff from CKD storage and landfill piles
has the potential to generate leachate containing hazardous characteristics. Runoff and
precipitation from CKD piles have exhibited pH levels above 12.5, which can be highly
corrosive. The EPA has also expressed apprehension regarding uncontrolled transport,
storage, and disposal of large volumes of CKDs in uncovered and unlined piles that are
easily removed by wind and eroded by water (EPA, 1993). Due to the leachate and
fugitive dust concerns, standards and guidelines have been developed for management of
CKD stockpiles and landfills.
24
2.2 CKD and Portland Cement
A basic understanding of CKD compositions and variabilities is fundamental to any
investigation of their use. CKDs never contain just a single component and the range of
the components and fineness varies not only with the type of cement kiln operation, but
also with the raw materials. The chemical, mineralogical, and physical property
differences among CKDs and between CKDs and PC must be well understood in order to
understand the potential effects in concrete. CKDs are derived from the same raw
materials and pyroprocess as clinker. Since CKDs are only partially burnt (relative to
fully burnt clinker), CKD compositions differ from PC (Corish and Coleman, 1995). The
fineness of a CKD can also be a factor in its influence on concrete properties and is an
additional component to be considered.
2.2.1 Chemical Properties
Sreekrishnavilasam et al. (2006) summarized statistics on the chemical oxide
composition of CKDs based on 63 published datasets from different cement plants, as
shown in Table 2.5. The table presents a statistical analyses of the main oxides present in
CKDs as well as the total alkalis (based upon equivalent sodium molar mass), loss on
ignition (LOI), and free calcium oxide content (note: free calcium oxide content was not
available for all datasets).
The chemical composition of PC is usually given as oxides on a mass percent basis,
determined by various analytical tests, such as those in ASTM C114. PC has a typical
range for each of the four main oxides: CaO (60 – 66%), SiO2 (19 – 25%), Al2O3 (3 –
8%), and Fe2O3 (1 – 5%) (Taylor, 1997). There are five categories of PC in ASTM C150
with equivalent cement types in CSA: ASTM TI and CSA-GU (normal/general use),
ASTM TII and CSA-MS (moderate sulfate resistant), ASTM TIII and CSA-HE (high
early strength), ASTM TIV and CSA-LH (low heat of hydration), and ASTM TV and
CSA-HS (high sulfate resistant). In 2005, a survey of the 123 cement plants in North
America was conducted to determine the chemistry of the different categories of PC
25
manufactured in North America (Tennis and Bhatty, 2006). The data from the 92 cement
plants that responded is presented in Table 2.6. The free calcium oxide and chloride
contents for PC normally appear in minimal quantities and are therefore, not typically
reported. Lawrence (1998a) reported that 132 samples of PC had an average free lime
content of 1.24% in a range of 0.03 – 3.68%. PC chloride content is typically less than
0.01%. Tennis and Bhatty (2006) did not present data for TIV, as it is not produced in
significant amounts in North America.
Table 2.5 CKD chemical oxide composition, free lime, and loss on ignition, and
statistical analysis of 63 published datasets (Sreekrishnavilasam et al., 2006)
Chemical Composition, %
CaO SiO2 Al2O3 Fe2O3 MgO SO3 Na2O K2O
Equivalent Alkali %
fCaO & Ca(OH)2
%
Loss on Ignition
%
Average 43.99 15.05 6.75 2.23 1.64 6.02 0.69 4.00 3.32 6.75 21.57
Standard Deviation 8.01 4.74 7.83 1.04 0.68 3.93 1.02 3.01 2.44 7.83 8.50
COV (%) 18 31 116 47 41 65 147 75 74 116 39
Max. 61.28 34.30 27.18 6.00 3.50 17.40 6.25 15.30 11.42 27.18 42.39
Min. 19.4 2.16 0.00 0.24 0.54 0.02 0.00 0.11 0.14 0.00 4.20
COV (%) = Co-variance Equivalent Alkali: Na2O + 0.658 x K2O fCaO: free calcium oxide (free lime) Ca(OH)2: Calcium hydroxide
Table 2.6 Portland cement chemical oxide composition, total alkali content, and loss on
ignition (Tennis and Bhatty, 2006)
Chemical Composition, % Type of Portland Cement (ASTM)
CaO SiO2 Al2O3 Fe2O3 MgO SO3
Equivalent Alkali %
Loss on Ignition
%
TI Normal: Average 63.23 20.17 5.07 2.66 2.51 3.26 0.70 1.52
Standard Deviation 1.04 0.66 0.54 0.44 1.02 0.62 0.26 0.48
TII Moderate Sulfate Resistant: Average 63.66 20.85 4.62 3.32 1.98 2.91 0.56 1.39
Standard Deviation 0.84 0.52 0.37 0.40 0.92 0.39 0.26 0.40
TIII High Early Strength: Average 63.33 20.38 4.84 2.86 2.21 3.60 0.61 1.51
Standard Deviation 0.93 0.70 0.64 0.59 0.93 0.55 0.27 0.41
TV Sulfate Resistant: Average 63.85 21.61 3.80 3.87 2.18 2.34 0.45 1.29
Standard Deviation 0.66 0.67 0.35 0.67 0.91 0.28 0.12 0.44
Equivalent Alkali = Na2O + 0.658 x K2O
26
The data in Table 2.5 indicates that calcium and silica oxides are the major constituents
for CKDs, although these values are lower than what is found for PC in Table 2.6. Free
calcium hydroxide can sometimes appear as calcium hydroxide due to exposure to
moisture. The CKD combined free calcium oxide and calcium hydroxide contents and
LOI are significantly higher than in PC for this dataset. It is also observed that CKDs
generally contain higher concentrations of sulfates and total alkalis than PC. These
findings are not surprising since volatiles are preferentially drawn towards CKD in the
kiln pyroprocess. The alumina, iron, and magnesium concentrations of CKD and PC
appear to be similar. The CKDs tend to have higher concentrations of potassium than
sodium in this dataset, which is to be expected since there is usually a similar ratio for
cement raw materials in North America. Although not included in Table 2.5, chlorides
can appear in significant levels in CKDs. In an early study, Haynes and Kramer (1982)
reported that 113 CKD samples from 102 cement plants in the U.S had an average
chloride content of 0.71% with a range between less than 0.01% to as high as 12.3%.
Similar to other construction materials, PC and CKDs have a wide range of trace metals.
Trace metals reported in clinker and CKD analyses are normally present in quantities
small enough not to influence the performance of the cement (<0.05%) (Corish and
Coleman, 1995). Small quantities of trace metals only leach out of CKDs using vigorous
procedures such as the U.S. EPA toxicity characteristic leaching procedure (TCLP)
(Corish and Coleman, 1995).
2.2.2 Mineralogical Properties
The Portland Cement Association (Hawkins et al., 2004) compiled a mineralogy
summary table (Table 2.7) of 113 CKD samples from 102 cement plants in the U.S. by
X-ray diffraction using raw data from the research conducted by Haynes and Kramer
(1982). Of the 113 CKD samples, 106 had a calcite level greater than 30%, which
indicates that the majority of the CKDs were from wet or long-dry kilns (CKDs from
preheater and precalciner kilns generally have low calcite and high free lime levels).
27
Additional common minerals found in the 113 CKDs, although to a lesser degree than
calcite, were: free lime (CaO), anhydrite (CaSO4), quartz (SiO2), dolomite
((CaMg(CO3)2), mica, and feldspar. Other minerals found in only a number of the
samples were: aphthitalite ((K,Na)2SO4), arcanite (K2SO4), sylvite (KCl), portlandite
(Ca(OH)2), halite (NaCl), gypsum (CaSO4.2H2O), and chlorite
(Mg3(Si4O10)(OH)2.Mg3(OH)6). Althought it is reported that CKDs coming from zones of
high temperatures in wet and long-dry kilns often contain silicate compounds (i.e. C2S)
(Adaska et al., 1998), it is surprosing that Haynes and Kramer (1982) did not report the
presence of PC primary compounds in any of the CKDs.
Table 2.7 Mineralogical composition of U.S. CKD samples (Hawkins et al., 2004)
Alkali chlorides and alkali sulfates in CKDs are of particular interest as they tend to be
water soluble and enter solution in the early stages of hydration. Usually potassium is
more volatile than sodium in the kiln. The molar ratio of sulfate to water soluble alkalis
may indicate which sulfate phases are likely to be present in a CKD. Since chlorides are
not always present in the raw materials, very little is discussed in the literature regarding
alkali chloride formation in the pyroprocess. Due to the lower volatilization temperature
28
of chlorides as compared to sulfates, it is believed that chlorides will preferentially
combine with alkalis before sulfates (Lehoux, 2006).
The formation of the alkali sulfates depends upon the available amounts of the remaining
alkali and sulfate ions. Potassium and sulfur have a very high mutual affinity. Alkalis and
sulfate will preferentially form the double alkali sulfate, aphthitalite (3K2SO4.Na2SO4),
and/or the single alkali sulfate, arcanite (K2SO4). Arcanite will likely form if there are not
enough available sodium ions to produce aphthitalite. Thenardite (Na2SO4) will only
likely be present if the amount of sodium is greater than the amount of potassium in the
cement raw materials, which is rare in North America. In the cases where sulfate is
present in excess of the alkalis, the double salt known as calcium langbeinite
(2CaSO4.K2SO4) will likely form. If there is excess sulfate or a lack of potassium ions,
anhydrite (CaSO4) may also be present. Anhydrite, although water soluble, does not enter
solution as quickly as alkali sulfate compounds. There is no equivalent mineralogical
phase for sodium to mimic the potassium in calcium langbeinite (Bhatty, 2004).
The mineralogical composition of PC is most commonly determined using Bogue
equations that are described in North American Standards (ASTM C150, AASHTO M85,
CSA A3001). The data from the Tennis and Bhatty (2006) survey of the 123 cement
plants in North America for average Bogue compound composition and Blaine fineness
(surface area) of different PCs is presented in Table 2.8. The remaining 15% of PC
composition is the minor compounds that normally consist of gypsum (5%), limestone
(5%), magnesia (1%), the sodium equivalent alkali oxides (1%), and free calcium oxide
(1%).
29
Table 2.8 Portland cement average bogue compound and Blaine fineness in 2004 (Tennis
and Bhatty, 2006)
Type of Portland Cement (ASTM) C3S %
C2S %
C3A %
C4AF %
Blaine m2/kg
TI Normal Standard Deviation
56.9 4.57
14.8 3.71
8.9 1.81
8.2 1.37
384 19.3
TII Moderate Sulfate Resistant Standard Deviation
56.5 3.93
17.1 3.48
6.7 0.88
10.1 1.20
377 20.0
TIII High Early Strength Standard Deviation
56.2 4.13
16.2 3.91
7.8 2.14
8.8 1.80
556 55.5
TV Sulfate Resistant Standard Deviation
57.7 3.47
18.4 3.93
3.5 1.17
11.8 2.03
389 42.5
2.2.3 Physical Properties
Konsta-Gdoutos and Shah (2003) state that CKDs are generally off-white or light brown
in appearance. The limited number of research studies that provide fineness data typically
report Blaine fineness, relative density, and/or particle size distribution. The Blaine
fineness values of CKDs vary in the literature between 318 and 1400 m2/kg, which is
generally higher than the typical range of values for PC, as shown in Table 2.8.
Comparing the Blaine fineness values has led some researchers to conclude that CKDs
are finer than PC (Lachemi et al., 2008; Wang and Ramakrishnan, 1990; Ravindrarajah,
1982). The relative densities of CKDs have been reported to be typically between 2.6 and
2.8, which is closer to the density of raw material and less than the 3.15 relative density
typically assigned to PC (Konsta-Gdoutos and Shah, 2003).
PC consists of individual angular particles that are mostly (approximately 95%) smaller
than 45 µm. The average particle size of a PC particle is approximately 15 µm.
Peethamparan et al. (2008) presented the particle size distribution for four different fresh
CKDs and a Type I PC, as shown in Figure 2.5. CKD-1 (long-dry pyroprocess) and
CKD-2 (precalciner pyroprocess) had the finest and coarsest particle size distributions,
respectivley. CKD-3 (preheater/precalciner pyroprocess) and CKD-4 (wet pyroprocess)
had particle size distributions very similar to that of the Type I PC. CKD-3 and CKD-4
30
had a greater percentage of particles smaller than the PC up to between 10 and 20 µm,
but beyond 20 µm there was a smaller percentage of particles smaller than the PC. The
D50 values for the CKDs ranged between approximately 7.5 µm and 30 µm while the D50
value for the PC was approximately 15 µm.
Figure 2.5 CKD and PC particle size distribution (Peethamparan et al., 2008)
CKD Pyroprocess CKD 1: long-dry CKD 2: precalciner CKD 3: preheater/precalciner CKD 4: wet
31
Sreekrishnavilasam et al. (2006) presented the particle size distribution of five fresh
CKDs, one PC, two microcements, and one landfill CKD from previous studies, as
shown in Figure 2.6. The authors stated that the various CKDs show significant variation
in the mean particle size (D50 = 2.8 µm to 55 µm) as well as in the gradation (Cu = 5 to
25). Each CKD has a greater percentage of particles smaller than the PC between 0 and 8
µm. This shows that the CKDs contain more fine particles (smaller than 8 µm) than the
PC. Beyond 8 µm, however, the CKD particle size curves are on both sides of the PC
particle size curve.
Figure 2.6 CKD and PC particle size distribution from published literature
(Sreekrishnavilasam et al., 2006)
32
2.2.4 CKD Types
Inconsistency of any material can inhibit its use in construction applications. In realistic
terms, there is no typical or average CKD. The characteristics of CKDs vary from plant
to plant depending on the kiln feed composition, kiln design and operation, fuel type, and
the type of dust control systems (Hawkins et al., 2004). Therefore, a distinct CKD that is
used as a partial substitute of a PC at a given replacement level may perform differently
from another CKD that is used as a partial substitute of the same PC at an equivalent
replacement level.
The typical composition of CKDs covers a wide range of values as shown in Table 2.5
and Figure 2.6. Despite the fact that PC from cement plants across North America has
relatively little variation due to adherence to cement standard specifications, components
found in CKDs vary significantly. CKD composition differences among cement plants
are due to variations in raw materials, fuels, equipment design, and kiln operations.
As shown in Table 2.5, free calcium oxide content and LOI show large variation in
CKDs, although they only appear in minimal amounts in PC. Sreekrishnavilasam et al.
(2006) reported that the majority of CKDs in the literature studies have low free calcium
oxide contents (less than 5% free calcium oxide for 40 out of 43 samples). This implies
that the majority of CKDs in this sample set are from either wet or long-dry kilns. CKDs
from the wet and long-dry processes typically have much lower free calcium oxide (free
lime) and higher LOI than CKDs from the preheater/precalciner processes (Hawkins et
al., 2004). As preheater/precalciner pyroprocesses become more prominent in the cement
industry, the number of cement plants generating CKDs with free calcium oxide
concentrations greater than 20% will increase.
The concentration of volatiles in CKDs can be influenced by the type of fuel used in the
pyroprocess. Coal fuel has more sulfur than oil and gas fuels, which can increase the
concentration of volatiles in the pyroprocess. As well, oil and gas fuels tend to volatilize
33
more alkalis as compared to coal fuel. This is perhaps due, at least in part, to the higher
hydrogen levels in these fuels, which leads to higher water vapour concentrations in the
burning zone. Consequently, CKD from gas or oil fired kilns contain higher proportions
of soluble alkalis as compared to those from coal fired kilns (Klemm, 1980).
The variability of CKD particle size distributions can be largely attributed to differences
in dust collection systems and pyroprocess technologies. Some dust collection systems
are able to separate the fine CKDs from the total CKDs. There are often significant
chemical differences between total and separated CKDs, with the finer CKDs usually
having higher concentrations of volatiles and a lower free calcium oxide content (Collins
and Emery, 1983). CKDs from the bypass of precalciner kilns have also been described
to be coarser than CKDs from wet and long-dry kilns (Klemm, 1980).
Bhatty (1984, 1985a, 1985b, 1986) is the only researcher that has studied CKD-PC
interaction to categorize CKDs according to their compositions. The CKD classification
system used by Bhatty (1985b) was (i) low alkali-low chloride-low sulfate; (ii) low
alkali-low chloride-high sulfate; (iii) moderate alkali-low chloride-moderate sulfate; and
(iv) high alkali-high chloride-low sulfate. This illustrates the necessity to differentiate
CKDs according to their composition in considering their potential impact on cement
properties.
34
2.2.5 Variability of CKD from a Single Plant
The composition of CKDs not only varies between different cement plants, but CKD can
also vary from batch to batch within the same plant (Wang and Ramakrishnan, 1990). It
is very difficult to produce a homogenous CKD from the pyroprocess and cement plants
do not attempt to do so since a large portion is destined for landfills. Table 2.9 presents
summarized statistics on the CKD chemical oxide composition of intermittent daily
samples collected from a single kiln (long-dry process) over a 3-year period. Although
more variable than PC, the CKDs from a specific cement plant will generally have
considerably less compositional variation than the CKDs given in Table 2.5, which are
from a wide variety of sources (Corish and Coleman, 1995). As an example, the CKD
standard deviation of SO3 content from the single long-dry process plant is 1.53%, while
that from a wide variety of sources is 3.93%.
Table 2.9 CKD oxide composition and statistical analysis of intermittent daily samples
collected from a single kiln (long-dry process) over a 3 year period (2005 – 2008) in
North America (Lafarge, 2009)
Component SiO2 Al2O3 Fe2O3 CaO SO3 MgO K2O Na2O TiO2 P2O5 SrO Mn2O3 Cl
Average 14.91 4.11 1.43 43.86 5.78 1.20 2.59 0.13 0.20 0.05 0.06 0.06 0.43
Standard Deviation
0.91 0.24 0.13 2.61 1.53 0.22 0.67 0.04 0.01 0.00 0.01 0.01 0.15
No. of samples
565 565 565 565 565 565 565 565 565 565 565 565 565
As knowledge regarding the use of CKDs in concrete improves, the cement industry may
look to invest in the systems and resources that will be required to produce CKDs with
less variability from an individual cement plant. CKDs that will be used as a partial
replacement of PC must be handled in a fashion that is similar to conventional PC to
ensure a consistent and high quality product (sampling ports for quality monitoring,
metering systems, pneumatic handling systems, and silos for storage).
35
2.3 Portland Cement Hydration
Any study on the use of CKDs as a partial replacement of PC first requires an
understanding of PC hydration. C3S and C2S both react with water to form calcium
silicate hydrate (C-S-H) and calcium hydroxide (CH) (also known as portlandite). The C-
S-H provides most of the strength developed by PC. C3S hydration occurs more rapidly
than C2S hydration. Therefore, C3S provides most of the early age strength while C2S
contributes mostly to the later age strength (Gartner et al., 2002).
The reaction between PC and water is mostly an exothermic reaction that takes place in a
sequence of stages. Traditionally, isothermal conduction calorimetry has been used to
follow the progression of hydration by monitoring the rate of heat liberation of the
cement paste. Most researchers have identified five stages of PC hydration. A typical
isothermal conduction calorimetric curve for a Type I PC is shown in Figure 2.7 with the
stages of hydration indicated as: (1) initial reaction, (2) induction, (3) acceleration, (4)
deceleration, and (5) slow continued reaction (Taylor, 1997). The main hydration peak
occurs during stages 3 and 4 and is associated with C3S hydration that produces C-S-H,
the main component that contributes to PC paste strength. The intensity and location of
the sulfate depletion peak, characterized by the formation of monosulfate during stages 4
and 5, are normally dependent on the amount of C3A and sulfate in the cement (Tennis
and Kosmatka, 2004). A representation of the relative volumes of the major compounds
in the microstructure of hydrating PC pastes as a function of time is shown in Figure 2.8.
36
Figure 2.7 Heat evolution of PC paste during hydration stages: (1) initial reaction, (2)
induction, (3) acceleration, (4) deceleration, and (5) slow continued reaction (Gartner et
al., 2002)
Figure 2.8 Relative volumes of the major compounds in the microstructure of hydrating
PC pastes as a function of time (Odler, 1998)
C
2
3
4
5
37
It is widely accepted that gypsum is added to PC to control the reaction of C3A. Most
researchers believe that this allows the setting and hardening to be controlled by the C3S
and water reaction (Gartner et al., 2002). Gypsum and alkali sulfates provide readily
soluble sulfate that surrounds the C3A and forms ettringite (C3A.3CaSO4.H2O32). There
are other ions that can partially or completely replace sulfate, whereas iron and silica may
substitute for alumina. Therefore, ettringite in cement paste should be indicated by the
more general AFt (Gartner et al., 2002). The AFt continues to form if sufficient sulfate
ions are present in the solution. Once the sulfate is depleted, the remaining C3A reacts
with the AFt to form monosulphates (AFm). The hydration of the C4AF forms hydration
products similar to C3A, both with and without gypsum (Gartner et al., 2002). Without
the presence of calcium and sulfate ions, the C3A reacts very rapidly with water to
produce calcium aluminate hydrates, such as C3AH6. The formation of calcium aluminate
hydrates at this stage is undesirable as they may cause rapid setting of the PC as a whole
(flash set).
Many factors other than the four major components of PC can impact cement paste,
mortar, and concrete properties. Besides the clinker composition, the presence of minor
oxides may also affect the resultant cement strength. For example, the uptake of elements
(i.e., sulfate or alkali) in the C-S-H formation can occur during hydration of C3S (Taylor,
1997).
2.3.1 Initial Hydrolysis
The first stage of PC hydration is initial hydrolysis. As soon as PC contacts water, an
initial heat peak occurs that mainly involves C3A, C4AF, alkali sulfates, free lime, and
calcium sulfates. The C3A and C4AF first react very rapidly and exothermally, which
results in the contribution of calcium and aluminate ions into solution. Iron is not
typically soluble. The aluminate concentration then reduces within seconds due to the
precipitation of AFt, which forms a layer over the cement particles. Alkali sulfates,
hemihydrates, and gypsum provide the readily soluble sulfates which contribute to AFt
38
formation at this stage. Free lime usually dissolves rapidly and exothermally but the
amount varies widely depending upon its reactivity. Reactive free lime in sufficient
amounts can lead to portlandite supersaturation (Gartner et al., 2002).
The dissolution of alkali sulfates is very rapid and endothermic. The alkalis enter into
solution and reach constant concentration within one minute of hydration. In order to
balance the cations and anions in solution as SO3 begins to combine with other elements
to form AFt, the alkali sulfates are replaced by alkali hydroxides which rapidly increase
the pH of the solution. Dissolution of calcium sulfate proceeds more slowly (relatively
modest amounts dissolve within the first few minutes of hydration) and is mildly
exothermic. The rate and amount of calcium sulfate dissolution is affected by its form.
At normal temperatures, hemihydrate is the most soluble form of calcium sulfate,
dihydrate is less soluble, and anhydrite is the least soluble. PCs that contain high levels of
metastable sulfates – such as hemihydrate and calcium langbeinite – often react to form
the precipitate phases gypsum and/or syngenite. These phases can lead to observable
changes in workability (Gartner et al., 2002).
2.3.2 Induction
The second stage of PC hydration is a period of reduced heat evolution after the initial
reaction. The lack of heat evolution, however, does not mean there is nothing occurring.
The slow formation of early C-S-H and AFt leads to an increase in viscosity. The causes
of the induction period and its termination have been the subject of many studies (Taylor,
1997). Many of these studies have used the hydration of C3S as a model for the hydration
of PC. Although there has been much debate, Taylor (1997) stated that the balance of the
evidence favours a combination of two hypotheses for the cause and end of induction.
The first hypothesis is that the induction phase causes the formation of a protective layer
on the C3S particles, the induction phase ending when this layer is destroyed or rendered
more permeable by aging or phase transformation. The second hypothesis states that the
39
rate of reaction in the induction phase is controlled by nucleation and growth of the C-S-
H formed in the main reaction; the induction period ends when C-S-H growth begins.
The termination of the induction period coincides with crystallization of calcium
hydroxide. The length of the induction period seems to depend upon how quickly the
calcium concentration rises to reach the maximum calcium hydroxide supersaturation.
This supports the idea that a certain minimum calcium hydroxide concentration is
required for the onset of the acceleration stage (Gartner et al., 2002). Setting does not
occur during the induction phase unless abnormal setting occurs. Flash set is a common
form of abnormal setting and occurs when there is an inadequate supply of calcium and
sulfate ions to react with the C3A, which results in the early formation of
monosulfoaluminate (AFm) phases. False set, another common form of abnormal setting,
most commonly occurs when there is an excess of sulfate in the liquid phase leading to
secondary gypsum formation. A false set paste can be re-mixed to regain its plastic form,
while a flash set paste cannot.
2.3.3 Acceleration
The acceleration phase of PC typically represents the change from a plastic to rigid
consistency (initial and final set) and early strength development. Initial set, as defined in
ASTM C150, is the time it takes for the depth of penetration of a needle in paste to be
less than 25 mm within 30 seconds. Setting is the formation of a network of partially
hydrated cement particles connected by PC hydration products (Nonat, 1994). Therefore,
as the water to solid ratio increases, the setting times will also increase. It is generally
accepted that initial setting is controlled by the hydration of C3S. Under normal
conditions, initial set and the transition from the induction phase to the acceleration phase
are reported to be correlated. The termination of induction will typically not correlate
with pastes that undergo abnormal setting (false or flash) since very little heat is evolved
during false set. It is important to note that the termination of induction and the beginning
40
of the acceleration are not always well-defined (Gartner et al., 2002). Final setting, as
defined in ASTM C150, normally occurs near the mid-point of the acceleration phase.
There is a high rate of heat evolution during this phase. The acceleration phase of C3S
hydration performs very similarly to the acceleration phase of PC. In both instances, the
main reaction is the formation of C-S-H and portlandite. It is generally accepted that the
rate of hydration in the acceleratory period is controlled by the nucleation and growth of
C-S-H. The rapid formation of hydrates leads to solidification and a decrease in porosity.
Sulfates, and possibly other ions, are significantly adsorbed and/or entrapped by C-S-H
(Gartner et al., 2002). The major heat peak of the PC hydration curve occurs at the end of
acceleration (Taylor, 1997).
2.3.4 Deceleration
The rate of C-S-H formation and portlandite decreases during the deceleration phase.
This results in reduced rate of heat evolution. There is general agreement that the main
reaction (C3S hydration) makes a transition from chemical control to diffusion control
sometime prior to the acceleration peak and continues in the deceleration phase. This is
likely due to the precipitation of hydrates surrounding the C3S particles, although the
form of the diffusion barrier is not clear (Gartner et al., 2002).
The sulfate in the liquid solution begins to decline due to continued formation of AFt as
well as uptake by the C-S-H. The sulfate depletion typically occurs between 12 and 36
hours and is indicated by a small peak during deceleration. At the time of sulfate
depletion there is a conversion of AFt formation to AFm formation. If there is an excess
amount of sulfate in the liquid phase and depletion does not occur, AFt will continue to
form until C3A is depleted.
41
2.3.5 Slow Continued Reaction
The continuous strength gain and reduction in porosity of paste, mortar, and concrete
occurs during the slow continued reaction phase, but at a continually decreasing rate.
Beyond one day, the only ions in solution above concentrations of a few mmol/l are
potassium, sodium, and hydroxyl ions. The concentrations of these ions tend to rise
slightly approaching a limit after about 28 to 90 days, primarily due to consumption of
the fluid phase (from ongoing hydration) (Taylor, 1997). Although the strength and
porosity development are important to the long term performance and durability of
concrete, hydration studies during this phase are limited (Mostafa and Brown, 2005).
2.4 Effects of CKD Properties and PC Dilution
The effects of different CKD-PC blends often provide conflicting and variable results,
due in large part to the compositional variability of CKD among different sources.
Although the effects of these components in combination and at varying replacement
levels are not well understood, there is considerable knowledge of the effects of each
individual component at varying replacement levels and dilution of PC. In an attempt to
understand the interaction of CKD-PC blends, it is important to appreciate how each
component of CKD replacement can individually influence hydration, performance, and
durability. In this way, it is possible to appreciate some of the potential effects of CKD. A
detailed explanation of the synergistic effects of a combination of the various components
within a CKD is beyond the scope of this literature review.
2.4.1 Calcium Carbonate
CKDs can consist of up to 50% calcium carbonate. Limestone is the most common form
of calcium carbonate in North America. The question of whether limestone additions
should be permissible has stimulated a great deal of debate and research. Various national
standards have adopted different positions. The European Standard (EN 197) allows up to
35% and North American Standards (CSA, ASTM, and AASHTO) allow up to 5%. CSA
will soon allow up to 15% limestone addition. The effects of the limestone as a partial
42
substitute of PC are both physical and chemical (Taylor, 1997). The chemical effects of
calcite will be discussed in this section. The physical effects of limestone addition are
covered in more detail in Section 2.4.10.
During normal PC hydration, C3A and calcium sulfate react to form AFt. Sulfate
depletion typically occurs before the C3A consumption is complete, resulting in the
conversion of AFt to AFm. The presence of calcium carbonate, however, alters these
reactions. First, AFt formation is accelerated in the presence of calcium carbonate
(Ramachandran and Zhang, 1986). Second, the conversion of AFt to AFm is delayed or
prevented due to the reaction between C3A and calcium carbonate to form calcium
carboaluminates. The formation of calium carboaluminates occurs as some of the sulfate
ions are replaced by carbonate ions during C3A hydration (Vernet and Noworyta, 1992).
Bensted (1980) investigated the use of limestone for partial substitution of the gypsum to
control the early hydration of C3A. Although he concluded that sulfate ions are more
effective than carbonate ions, Bensted (1980) also stated that it is possible to substitute
limestone for up to 50% of the gypsum without a deleterious effect. This has been cited
for the optimum sulfate content decrease when limestone addition increases (Cochet and
Sorrentino, 1993). The importance of the reactivity between C3A and calcium carbonate
additions is highlighted by reports that carbonate additions with sulfate resistant cement
(low C3A) act primarily as an inert diluent (Klemm and Adams, 1990).
Calcium carbonate additions also influence the hydration of C3S. Taylor (1997) stated
that the accelerating effect of carbonates in suitable concentrations appears to be confined
to the initial stage of reaction. The accelerating effect occurs with pure C3S as well as
with PC and is, therefore, associated with the behaviour of that phase. Limestone
enhances the rate of formation of C-S-H and CH, probably because it offers nucleation
sites for growth. Ramachandran (1988), however, reported that calcium carbonate also
forms a complex with the hydrated products of C3S. More recently, Pera et al. (1999)
43
reported that hydration of C3S in the presence of CaCO3 produced calcium carbosilicate
hydrate.
Barker and Mathews (1989) reported on the heat evolution of limestone filler cements.
Their studies indicated that as the amount of limestone increased, the major heat peak and
total amount of heat released both decreased. The time that the major peak appeared,
however, was dependent upon the method of limestone-PC blend preparation. Blending
the limestone with PC was shown to either have no effect or to retard the time of the
major peak, while intergrinding limestone and PC was shown to accelerate the time of the
major peak. Hooton (1990) determined the 7-day heat evolution (ASTM C186) for
commercially available PCs and limestone-PC blends made from the same clinkers. The
author reported that there was no consistent effect of limestone on the total heat of
hydration.
Sprung and Siebel (1991) reported reduced water demand with limestone filler cements
and attributed this to improved particle packing. Cochet and Sorrentino (1993) stated that
the water-reducing action of the fillers is greater for a water to cement ratio (w/c) of less
than 0.4, but this effect is dependent upon the quality of the limestone. A limestone from
clay rock deposits or soft and porous rock leads to an increase in the water demand and
reduces the positive effects of a limestone, discussed in further detail in Section 2.4.3.
Researchers have observed that the setting times are marginally reduced as the limestone
additions increase (Brookbanks, 1989; Vuk et al., 2001).
Hawkins et al. (2005) assessed the compressive strength data for mortars and concrete
made with and without limestone as being up to 6% in PC from various data sources.
This data analysis showed that up to 5% limestone addition can provide strengths similar
to PCs without limestone. Beyond the 5 – 10 % range of limestone addition to PC,
strengths are lower than for PC alone, due to the dilution effect. This effect can be offset
to an extent by grinding the limestone-PC blend finer (Sprung and Siebel, 1991).
44
The presence of calcium carbonate additions may increase the likelihood of thaumasite
(CaSiO3.CaCO3.CaSO4.15H2O) formation. Thaumasite formation occurs in cold and wet
environments by reaction of the C-S-H with sulfates and carbonate ions (Hooton and
Thomas, 2002). The thaumasite form of sulfate attack results in the decomposition of the
C-S-H and can completely destroy the binding capacity of the cement paste. The
conventional form of sulfate attack requires the involvement of C3A. Sulfate resistant
cement (low C3A), however, does not present any special protection from thauamsite
since the attack is in the silicate phase and not the aluminate phase. Although thaumasite
can cause severe damage, there are very few cases where it is the primary cause of
deterioration (Taylor, 1997).
2.4.2 Quartz
CKDs have been reported to contain up to 30% quartz. Quartz is inert (insoluble) and is
typically not found in PC. The partial replacement of PC with CKDs may have an impact
on cement properties due to the presence of unreactive raw materials within CKD. The
physical effects of quartz due to fineness (nucleation and filler effects) are discussed in
Section 2.4.10.
2.4.3 Clays
CKDs may contain clays or de-hydrated clays, although previous studies have not stated
this. PC generally does not contain clays, except those present in mineral additives such
as limestone. Since CKDs typically consist of partially decarbonated limestone, clays
may be present in CKDs. The presence of clay can lead to an increase in water demand
(Cochet and Sorrentio, 1993). The effect on hardened concrete is deleterious to freezing
and thawing resistance (Detwiler et al., 1996). Unreacted clay minerals could cause
problems in hardened concrete if they swell when exposed to water. There is also a
potential for an increase in sorption of certain cations, and no hydration products are
generated by clays in the presence of PC (Mattus and Gilliam, 1994). However, heat-
45
treated clays, such as metakaolin, can be pozzolanic. The pozzolanic reaction occurs in
the presence of calcium hydroxide and silica from the pozzolan to produce C-S-H, the
main PC hydrate that contributes to strength in concrete.
2.4.4 Free Lime and Calcium Hydroxide
CKDs generally have higher free limes than PC and have been reported to contain up to
40% free calcium oxide (free lime). A small portion of the free lime in CKDs is
sometimes found in the form of calcium hydroxide due to exposure to moisture.
Approximately 1.5% or less free lime is generally an advisable quantity for a given PC
(Bensted, 1983a). Free lime (uncombined lime) appears in the form of calcium oxide
(CaO) in clinker and is typically considered hard burnt. In PC, however, the addition of
damp gypsum and use of water spray to control temperature in the grinding mill can
hydrate some or all of the free lime to form calcium hydroxide. A large amount of the
hard burnt lime is not very reactive chemically towards water, but sufficient calcium and
hydroxyl ions are available in the solution phase during PC hydration to enable the
various chemical reactions that are influenced by calcium hydroxide to occur (Bensted,
1983a).
The calcium hydroxide formed by the hydration of C3S and that formed by hydration of
free lime are slightly different. The hydration of free lime to calcium hydroxide produces
poorly developed crystals that have a lower decomposition temperature using thermal
analytical methods such as thermal gravimetric analysis (TGA), differential scanning
conduction calorimetry (DSC), or differential thermal analysis (DTA) (Bye, 1999).
The hydration activity of free lime formed at different decarbonation temperatures is
variable. The rate of heat evolution of pure free calcium oxide decreases with increase of
firing temperature, as shown in Figure 2.9. The difference in microstructure of free
calcium oxide fired at various temperatures results in its different hydration activity.
When calcium carbonate initially decomposes at approximately 900˚C (Soroka, 1979),
46
the free lime retains its rhombohedral structure of calcite and the crystallite size is small.
It is known that reactive free lime (soft burnt lime) can significantly affect the rheological
properties of the CKD-PC mixture due to its high affinity for water molecules. With the
rise of decarbonation temperature, the crystals of free calcium oxide grow and change to
the cubic structure. Industrial free calcium oxide contains small amounts of SiO2, Al2O3,
Fe2O3, and other oxides and, consequently, the hydration reactivity is lower than that of
pure free calcium oxide (Shi et al., 2002).
Figure 2.9 Effect of firing temperature on the heat evolution of pure free calcium oxide
during hydration (Shi et al., 2002)
47
Gartner et al. (2002) has stated that the presence of free calcium oxide can enhance AFt
expansions. It appears that the formation of AFt in the presence of a deficiency of free
calcium oxide develops more blocky crystal with much less expansion and can rapidly
develop a strong matrix. The presence of calcium hydroxide has been reported to enhance
the ability of gypsum to retard the hydration of C3A (Collepardi et al., 1978; Brown et al.,
1984). The delayed formation of AFt and subsequent conversion to AFm has been
attributed to the development of a more effective AFt diffusion barrier.
Lime has an important role to play in the initial hydration of PC by supplying calcium
ions to the system. Nonat (1994) stated that the lime concentration is the most important
parameter during C3S hydration that determines thermodynamic, kinetic, morphological,
and structural formations of C-S-H. Therefore, any change in lime concentration or
displacement of the solubility equilibrium of portlandite – such as the addition of calcium
salts or alkalis – may change the formation characteristics of C-S-H. Nonat (1994) also
reported that the lime concentration in solution determines both the particle interactions
and solubility of hydrates that control the origin of setting. The duration of the induction
period, however, depends essentially on the number of nuclei of C-S-H precipitated from
the solution in its state of maximum supersaturation with respect to C-S-H. Therefore, the
lower the lime concentration, the greater the number of nuclei and, as a consequence, the
shorter the induction period (Damidot and Nonat, 1992). Since, under normal conditions,
initial set and the end of the induction period are reported to have a strong correlation
(Gartner et al., 2002), it is likely that an increase in lime concentration would retard the
induction period and, hence, the initial setting time. Nonat (1994) also reported that a
decrease in the w/b ratio of pastes mixed with saturated limewater shortened the
induction period due to the increase in the number of contacts between particles, even
though the number of initial nuclei is reduced due to a higher concentration of lime in
solution.
48
The free lime that reacts after cement has set will form calcium hydroxide. The volume of
calcium hydroxide is greater than the original free calcium oxide, which causes
expansion and damages the concrete internally. This type of expansion is called
unsoundness (Neville, 1996). Soundness cannot be predicted reliably from the free lime
content due to the varying hydration activity of free lime. Soundness issues related to free
lime reactivity occur after the paste is set, so it is likely that the hard burnt free lime at
high temperatures will cause soundness issues. Soft burnt lime hydrates rapidly before
the paste has set and, therefore, does not produce unsoundness.
2.4.5 Magnesia
The amount of magnesia oxide in CKDs is characteristically similar to that found in PC.
CSA A3001 and ASTM C150 limit the total magnesia content in PC to 6% by mass.
Magnesia is mostly present in the main silicate phases of PC, but some may be present as
crystalline magnesium oxide (periclase). Similar to free calcium oxide, the reactivity of
magnesia oxide depends upon the temperature at which thermal decomposition from
magnesium carbonate occurs. At lower temperatures of decomposition (700°C –
1000°C), the magnesia oxide may react with water prior to set, and thus not contribute to
expansion in the hardened state. The magnesia oxide in PC that has been exposed to high
burning temperatures will react with water slowly over a period of years to form
magnesium hydroxide and potentially cause expansion (unsoundness) in the hardened
paste (Soroka, 1979). Therefore, the amount of magnesia oxide in CKDs may not be a
good indicator of potential unsoundness. The effect of periclase on soundness is also
influenced by its particle size and distribution in clinker. Slow cooling of clinker allows
large periclase crystals to form such that when these hydrate slowly in concrete, the
expansion can cause unsoundness (Manias, 2004). Therefore, rapid cooling of clinker is
preferred for smaller and uniformly distributed periclase crystals that have less impact on
soundeness (Peray, 1986).
49
2.4.6 Sulfate
Most CKDs have higher levels of sulfate in comparison to PC. The sulfates found in
CKDs typically occur as single sulfates (K2SO4 and/or Na2SO4), apthitalite
(3K2SO4.Na2SO4), calcium langbeinite (2CaSO4.K2SO4), and/or anhydrite (CaSO4). The
sulfate phases often identified in CKDs are also commonly found in the clinker fraction
of PC. Gypsum, which is added to clinker during PC grinding, is the most important
source of sulfate in PC. During PC hydration, calcium and sulfate ions are supplied by
gypsum to control the reaction of C3A. Although CKDs do not typically contain gypsum,
they could provide readily soluble calcium ions (from free lime and calcium langbeinite)
and readily soluble sulfate ions from alkali sulfates during the early stages of hydration.
Therefore, the effects of alkalis and calcium in conjunction with sulfate must be
considered in this review.
It is generally accepted that the alkali sulfates and combined alkali/calcium sulfates are
rapidly (within minutes) dissolved upon hydration, whereas alkalis present in the
aluminate, ferrite, and silicate phases are released more slowly (perhaps even over
months or years). Sandberg and Roberts (2005) stated that the rate of solubility of the
different sulfate forms vary in the following order (highest to lowest rate of dissolution):
alkali sulfate and calcium langbeinite > plaster (calcium sulfate hemihydrates) > chemical
anhydrite (soluble calcium sulfate anhydrite) > gypsum (calcium sulfate dihydrate) >
syngenite > natural anhydrite.
The amount of gypsum addition to PC is very important. The supply of sulfate ions
controls the setting and maximizes the early strength development of cement. This
process is disturbed if the renewed hydration of C3A takes place early. Therefore, it is
desirable to suppress the C3A hydration with an appropriate amount of sulfate so that it
does not coincide with the C3S hydration. The optimum amount of sulfate in PC should
(i) retard C3A hydration, (ii) inhibit C3A hydration until C3S hydration takes place to
cause the setting of the cement, and (iii) not form an excessive amount of ettringite to
50
cause deleterious expansion after the cement has set and hardened (Bhattacharja, 1997).
Each PC is unique and the optimum amount of gypsum for set control as well as other
properties – such as early compressive strength – must be determined individually. It is
also important to note that the optimum amount of gypsum is not the same for all
performance parameters (Gartner et al., 2002).
Tang and Gartner (1988) reported that the presence of soluble sulfates strongly retards
initial C3A hydration. In addition, the chemical and physical form is very important. The
interblended mixed alkali/calcium sulfates (calcium langbeinite and syngenite) are more
effective retarders of C3A than either gypsum or pure alkali sulfates alone. The proposed
mechanism takes into account the rate at which the sulfate phases can supply both
calcium and sulfate ions to the surfaces of the aluminate phases during early stage
hydration. Tang and Gartner (1988) concluded that the use of alkali/calcium double salts
increases the rate and chemical potential at which calcium and sulfate ions enter the
solution. Single alkali sulfates (K2SO4 and Na2SO4) and apthitalite (3K2SO4.Na2SO4),
however, are generally not known to be effective retarders of C3A hydration.
Lawrence (1998b) examined the heat of hydration for a PC with different levels of
gypsum addition, shown in Figure 2.10. With 0.5% sulfate addition to the PC, the heat
evolution of the aluminate peak that was originally superimposed on the main silicate
hydration peak was retarded and weakened, and at 2.5% sulfate addition, the aluminate
hydration peak was suppressed. Lawrence (1998b) also observed that the main silicate
heat peak is depressed at calcium sulfate levels above optimum.
51
(a)
(b)
(c)
Figure 2.10 Heat of hydration of cement paste determined by isothermal conduction
calorimetry, (20°C and w/c = 0.44); (a) PC (b) PC + 0.5% SO3, (c) PC + 2.5% SO3
(Lawrence, 1998b) Note: Sulfate added as Gypsum (Calcium Sulfate)
52
As the amount of gypsum added to a PC increases, the setting time also increases until a
level of stability is reached and the setting time becomes insensitive to further additions
of gypsum (Frigione, 1983). The hydration of silicate phases is accelerated in the
presence of calcium sulfates (Ish-Shalom and Bentur, 1972). The effect of calcium sulfate
on compressive strength at various ages of a PC is shown in Figure 2.11. It is clear that
the optimum sulfate is different for the three ages of compressive strength. Soroka and
Relis (1983) stated that the optimum content in the compressive strength curve for PC at
a particular age implies that the addition of gypsum involves two opposing effects. The
lower range of sulfate content has a beneficial effect on strength and can be attributed to
the allowance of C3S to hydrate to a beneficial strength by controlling C3A hydration.
The range of sulfate greater than the optimum has an adverse effect on strength. Two
suggested mechanisms of excessive sulfate ions are: (i) excessive AFt formation and the
associated volume increase cause internal cracking of the hardened paste and (ii) C-S-H
formation is accelerated but has lower intrinsic strength due to incorporation of sulfate
ions into its structure. Both mechanisms may contribute to the phenomenon caused by
excessive calcium sulfate (Gartner et al., 2002).
Abnormal setting behaviour is usually related to chemical reactions involving aluminates
and sulfate phases (Gartner et al., 2002). False set generally occurs when there is too
much readily soluble sulfate, which can come from plaster and/or alkali sulfates. The
liquid phase becomes over-saturated with sulfate and precipitation as secondary gypsum
occurs. The crystals of gypsum are needle-shaped and weak, but can still restrict the
workability of the mix. It is called false set because upon re-mixing the needles will
break-up and the mix will revert to its original consistency. Although not commonly
reported, false set may also arise due to precipitation of syngenite or ettringite (Gartner et
al., 2002).
53
Figure 2.11 Optimization of gypsum additions for compressive strength at different ages
(Gartner et al., 2002) (Note: this PC required higher SO3 levels than normal to obtain
maximum strength)
54
Excessive sulfate in PC can also lead to expansion problems due to formation of AFt. The
reaction between C3A and calcium and sulfate ions to form AFt involves increases in the
volume of solids. When the appropriate amount of calcium sulfate (optimum sulfate) is
present in PC, AFt formation occurs when the paste is plastic and volume increases do
not impact the integrity of the paste. At higher levels of sulfate (i.e., greater than
optimum sulfate), however, the formation of AFt may take place in the hardened paste
and possibly cause expansion and/or cracking (Soroka and Relis, 1983).
2.4.7 Chloride
The range of chloride content in CKDs from previous studies is between 0 and 12%. PC,
however, generally has less than 0.01% chloride content. The American Concrete
Institute (ACI 318) guideline for maximum water soluble chloride ion (Cl-) in concrete,
as a percent by mass of cement, is limited to: 1% for reinforced concrete exposed to
neither a moist environment nor chlorides, 0.15% for reinforced concrete exposed to a
moist environment or chlorides or both, and 0.06% for prestressed concrete.
CKD chloride ions generally appear as alkali chlorides (NaCl and/or KCl). Alkali
chlorides are more soluble than alkali sulfates and will enter solution within minutes of
hydration. Although calcium chloride in CKDs is rare, it is important to consider its
effects as well as those of alkali chlorides. Calcium ions could be present during the early
stages of hydration due to the presence of calcium-bearing phases that are readily soluble.
Therefore, the effects of alkali and calcium ions in conjunction with chloride ions are also
considered in this review. Bhatty (1984) also suggested that the alkali chlorides in CKDs
would probably behave similarly to calcium chloride.
Calcium chloride is a highly soluble salt that releases calcium and chloride ions into
solution and has long been used to shorten both the setting and hardening time of
concrete by accelerating the hydration reactions. Calcium chloride is one of the most
effective accelerators of PC pastes but the mechanism is not well understood. A practical
55
dosage is typically between 1 and 2%, by mass of cement, and its acceleration effects
increase as the concentration of calcium chloride increases (Juenger et al., 2005).
Potassium chloride (KCl) and sodium chloride (NaCl) are less effective accelerators than
calcium chloride. At very high concentrations, some salts (such as NaCl) act as retarders
of C3S (Taylor, 1997). Calcium ions are considerably more effective than any other
cation in salts used for accelerating hydration, suggesting that a specific effect is
superimposed on a general one (Taylor, 1997).
It is well known that the chemical binding of chlorides is influenced by the amount of
aluminate phases. C3A can react with chlorides to form calcium chloroaluminate hydrate
or Friedel’s salt (Taylor, 1990). The presence of sulfate ions in the binder, however,
reduces the chloride binding capacity of cement. Holden et al. (1983) attributed the
reduction in the chloride binding capacity to the preferential reaction of sulfate ions with
the C3A phase forming AFt. It is generally accepted that chlorides react with C3A only
after AFt formation is complete and sulfate depletion occurs (Taylor, 1997).
The effect of calcium chloride on PC heat evolution is shown in Figure 2.12. The
accelerated hydration of PC is indicated by a higher heat liberated at the major peak, the
shift of the major peak to the left side, and a narrower curve around the major peak. Early
strengths will tend to be higher but the final strengths will be reduced. Shoaib (2002)
also stated that the larger amounts of chloride present in CKDs can cause a sort of
crystallization of hydration products. The crystallization results in opening the pore
system within the hardened samples leading to a reduction in strength. It is well accepted
that the acceleration of PC hydration with calcium chloride is mostly due to an
acceleration of C-S-H growth. The presence of chlorides is typically associated with
higher early strengths (1 and 3 days) and lower later strengths (beyond 28 days). Despite
a significant amount of effort to understand the acceleration effect of chloride on PC
hydration, however, the detailed mechanism still remains unclear.
56
Figure 2.12 Effect of calcium chloride on heat development in PC (Lerch, 1944)
The presence of chlorides is a durability concern for steel reinforced concrete. The
chlorides that are not bound or that leach from the bound hydrates can contribute to steel
corrosion. The corrosion of steel in concrete is an electrochemical process and it is a
consequence of this corrosion that the surrounding concrete is damaged (Neville, 1983).
57
2.4.8 Alkalis
The CKD equivalent alkali contents (Na2O + 0.658 x K2O) from previous studies range
between 0.14 and 11.42%. The equivalent alkali content of PC is typically lower
(between 0.5 and 1%). Alkali cations in PC typically occur either as sulfates or in the
major clinker phases. The balancing anion sooner or later enters a hydration product of
low solubility and an equivalent amount of hydroxyl ion is released (Taylor, 1997).
Alkalis (potassium and sodium) in CKD that can greatly impact PC hydration normally
occur as readily soluble alkali sulfates and/or alkali chlorides. CKD alkalis can also occur
in less soluble form within other mineralogical phases.
In general, soluble alkalis are reported to accelerate hydration at an early age, which is
attributed to an increase in the permeability of the layer of hydration product surrounding
the alite grains after the reaction has become diffusion controlled (Neville 1983). Set time
may shorten due to the increased C3S hydration. It is widely reported that increasing
alkali content generally increases early strength (1 and 3 days) and decreases late strength
(28 day). However, these effects are modified by the gypsum content of PC. Osbaeck and
Jons (1980) reported that the alkali effects on strength are diminished or absent at
gypsum contents above the optimum sulfate level. Further, Jackson (1998) stated that
when alkalis are present as calcium langbeinite (2CaSO4.K2SO4), a reduction in early
strength and an increase of the same magnitude of strength at 28 days would not, relative
to a PC with less alkali sulfate, be unexpected.
Excess soluble potassium is widely known to precipitate syngenite which may lead to
early stiffening and false set. The presence of soluble alkalis can also impact the rate of
gypsum consumption and, thus, affects the levels of calcium and sulfate in solution. It has
been reported that the optimum gypsum content increases as the alkali content increases.
Calcium salts and alkali hydroxides that are both soluble can influence initial dissolution
of C3S due to the common ion effect (Gartner et al., 2002).
58
Increased alkali content in concrete presents durability concerns (Taylor, 1997). ASR is a
reaction between hydroxyl ions and certain forms of silica in aggregate to form ASR gel.
ASR gel formation causes durability problems that arise as a result of tensile cracks in
concrete. The presence of soluble alkalis can also influence air entrainment in fresh
concrete (Greening, 1967). Although the exact nature of this influence has not been
determined, it is believed that both the air content and the average size of the air voids
tend to increase with the amount of soluble alkalis. This can have an adverse effect on
freezing and thawing resistance.
2.4.9 Clinker Phases
CKDs can contain some or all of the four major clinker phases. Any changes in the
amount of C3A could impact the optimum sulfate balance. Due to the reduced amount of
silicates typically found in CKDs relative to PC and assuming all other parameters being
equal, the CKD strength gain contribution will be less than the contribution from the
replaced PC.
2.4.10 Physical Properties
The effect of CKDs as partial replacement of PC can be influenced by the CKD physical
properties. The overall particle size distribution of PC and CKDs is called “fineness.”
CKDs may tend to have more fine particles than PCs below 8 µm (Section 2.2.3). The
densities of CKDs are generally lower than the PC industry standard of 3.15 (Konsta-
Gdoutos and Shah, 2003). Consequently, when CKDs are used as a partial replacement of
PC by mass, more CKD particles are required to replace the PC, which may affect
rheological properties. The fineness of a CKD will likely affect its chemical reactivity,
ability to act as a filler material (providing nucleation sites for hydration), and soundness
as a partial replacement of PC.
59
There is a strong correlation between fineness of PCs and water demand, as shown in
Figure 2.13. As the Blaine fineness (specific surface area) of a PC increases, the water
demand also increases, which is likely in part related to increased chemical reactivity
during the early stages of PC hydration. Increased Blaine fineness of a CKD may allow it
to have more impact on early age hydration in a CKD-PC blend by means of increased
ion dissolution. Therefore, a CKD-PC binder that has increased chemical reactivity
during early stages of hydration in comparison to the PC alone may also have a higher
water demand.
Figure 2.13 Relationship between water demand and specific surface area of PC (Sprung
et al., 1985)
CKDs may also contain significant amounts of calcite and quartz, which are both widely
known to be fillers (although it is recognized that limestone does chemically react with
aluminate phases to form carboaluminates). The presence of fine calcite and quartz
particles generally accelerates early PC hydration (Taylor, 1997). Greater fineness of the
CKD filler components could increase the hydration rate of the CKD-PC binder, most
likely by an increased surface area that also increases the number of active sites for the
60
nucleation of PC hydration products (nucleation effect). Alternatively, CKDs may
contain fine calcium carbonate particles that could fill the gaps between the cement
particles; improved particle packing of very fine filler has been attributed to reductions in
water demand as well as higher compressive strengths (Hawkins et al., 2005; Sprung and
Siebel, 1991).
The fineness or specific surface of the PC is one of the factors that influence the
autoclave expansion soundness assessment. If all other parameters of a PC are equal,
coarser ground cements have always exhibited a greater amount of autoclave expansion
(Klemm, 2005). Narang et al. (1981) quantified the effects of PC fineness on autoclave
expansion using a high MgO content PC. The PC was initially ground to a fineness of
225 m2/kg and had an autoclave expansion of 7.06%. When the same PC was ground to a
higher fineness of 350 m2/kg, the autoclave expansion was reduced to 1.39%. At an even
higher fineness of 400 m2/kg, the autoclave expansion was reduced to 0.24%.
Consequently, a reduction in fineness of a CKD-PC blend in comparison to the PC alone
may have an adverse effect on the soundness.
2.5 CKD-PC
The study of CKDs as a partial replacement of PC has been an intermittent research area
for the past 30 years. A list of the CKD-PC interaction studies, the number of CKD and
PC used, CKD replacement levels of PC investigated, the type of specimens used (paste,
mortar, and concrete), and the recommended limit of CKD replacement of PC for each
study are summarized in Table 2.10. Although these studies have shown that CKDs can
be used as a partial replacement of PC in the range of 5% to 15%, very little is known
about their exact role in cement paste, mortar, and concrete performance. The studies that
have been published on the use of CKDs as a partial substitute for PC often report
conflicting effects and mechanisms.
61
This section summarizes the materials, test methods, results, and conclusions of CKD-PC
interaction studies conducted over the past 30 years. Performance tests and properties for
CKD–PC blends – such as workability and water demand, setting time, hydration,
compressive strength, tensile and flexural strength, volume stability, and durability – are
presented. In order to focus on understanding the interaction between CKD and PC, the
literature review only considers studies of binary mixes.
Table 2.10 Summary of previous CKD-PC studies from literature review
Author # of
CKD # of PC
% CKD Replacement Tested P / M / C
Maximum % CKD Replacement
Recommended
Maslehuddin et al. (2008b) 1 2 0, 5, 10, 15 C 5%
Maslehuddin et al. (2008a) 1 1 0, 5, 10 P, M 10%
El-Aleem et al. (2005) 1 1 0, 2, 4, 6, 8, 10 P, M 6%
Al-Harthy et al. (2003) 1 1 0, 5, 10, 15, 20, 25, 30 M, C 5%
Udoeyo and Hyee (2002) 1 1 0, 20, 40, 60, 80 C N.R.
Wang et al. (2002) 1 1 0, 15, 25, 50 P, M 15%
Konsta-Gdoutos et al. (2001) 1 1 0, 15, 25 M 15%
Shoaib et al.(2000) 1 1 0, 10, 20, 30, 40 C <10%
Dyer et al. (1999) 2 1 0, 20, 35, 50, 75 P, M N.R.
Batis et al. (1996) 2 1 0, 6 C 6%
El-Sayed et al. (1991) 1 1 0, 3, 4, 5, 6, 7, 10 P, M 5%
Wang and Ramakrishnan (1990) 1 1 0, 5 P, M, C 5%
Ramakrishnan and Balaguru (1987) 1 3 0, 5 C 5%
Ramakrishnan (1986) 1 1 0, 5 P, M, C 5%
Bhatty (1986) 3 1 0, 10 M N.R.
Bhatty (1985b) 4 4 0, 10, 15, 20 P N.R.
Bhatty (1985a) 3 1 0, 10, 20 M N.R.
Bhatty (1984) 5 5 0, 10, 15, 20 P N.R.
Ravindrarajah (1982)
1
1
0, 25, 50, 75, 100 (P) 0, 15, 25, 35, 45 (C)
P, C
15%
CKD = Cement Kiln Dust; PC = Portland Cement P = Paste; M= Mortar; C = Concrete N.R. = Not Reported
62
2.5.1 CKD-PC Material Characterization
To effectively assess the effects of CKD as well as its reaction mechanisms involved as a
partial substitution of PC, it is essential to take into account the physical, chemical, and
mineralogical properties of both CKD and PC. The impact of CKD in a binary mixture
may be affected not only by the characteristics of the kiln dust, but also by the
characteristics of the cement.
The composition of CKDs that are removed from the pyroprocess is dependent upon the
raw material, fuel, kiln pyro-process, dust collection system, and type of cement being
produced. As a result, the composition of CKDs varies with respect to chemical
composition, particulate size, and mineralogy. Although there are variations among the
CKDs produced by different pyroprocesses and even within the same pyroprocess, there
are also similarities across all types of CKDs. All CKDs are a particulate mixture of
partially calcined and unreacted raw feed, clinker dust, and ash enriched with alkali
sulfates and other volatiles. All CKDs are also small enough to be carried by the
pyroprocess exhaust gases (Hawkins et al., 2004).
2.5.1.1 CKD-PC Chemical Composition
Bhatty (1984, 1985a, 1985b, 1986), one of the earliest published researchers to study
CKDs as a partial replacement of PC, stated that the chemical components of CKDs that
can affect cement/mortar/concrete properties are sulfates, alkalis, chlorides, free lime, and
calcium carbonate (CKDs typically contain higher concentrations of these chemical
components than PC). The chemical composition of the CKDs and PC used in each
CKD-PC interaction study over the past 30 years are presented in Table 2.11 and Table
2.12, respectively.
63
Very few researchers have characterized the complete chemical composition of the
CKD(s) used in their CKD-PC research study. From Table 2.11, it can be observed that
the CKD chemical components Bhatty (1985a) identified as affecting
cement/mortar/concrete properties are rarely reported; this is likely due to analyzing the
CKDs with the same procedures as for PC. For the chemical components that have been
reported, it is clear that the CKDs from different research studies, and even within the
same study, vary significantly. CKD chemical composition variabilities are heavily
influenced by variabilities in raw feed, fuel type, kiln process type, and product
specifications for the PC produced (Konsta-Gdoutos and Shah, 2003).
Table 2.12 shows the chemical composition of the PC that was used in each previous
research study to assess the use of CKDs as a partial substitute. The majority of the
previous research studies utilized TI cements. PC’s other than TI cement (PC 2, PC 12,
PC 13, and PC 14) were excluded from the statistical analyses in Table 2.12.
The chemical variability of the TI cements is considerably lower than that of the CKDs.
Since it is one of the volatile components, chloride (Cl) is not typically present in PC
(generally less than 0.01%) and, therefore, not reported. Typically the concentrations of
free lime (fCaO) in PC are low (typically less than 1.5%). Both chloride and free lime,
however, have a wide variation in CKDs. For the CKD free lime values reported, the
literature review does not cover the full range of free lime found in CKDs. The maximum
free lime reported in the literature review is 21.7%, whereas some CKDs have been tested
to contain as high as 35% free lime (Lafarge, 2005). The alkali (Na2O, K2O) and sulfate
(SO3) contents of the CKDs are generally higher in CKDs than in the TI cements. The
calcium oxide (CaO) and silica oxide (SiO2) contents of the CKD are generally lower
than in the TI cements, mainly as a consequence of partial decarbonation.
64
Table 2.11 Chemical and physical composition of CKD: from CKD-PC literature review
CaO SiO2 Al2O3 Fe2O3 MgO SO3 Na2O K2O Na2Oe Cl fCaO LOI Blaine
Author Material* % % % % % % % % % % % % m2/kg
Maslehuddin et al. (2008a and
2008b) CKD 1 49.3 17.1 4.24 2.89 1.14 3.56 3.84 2.18 5.27 6.9 N.R. 15.8 N.R.
El-Aleem et al. (2005) CKD 2 42.99 13.37 3.36 2.29 1.90 5.10 3.32 3.32 5.50 7.50 2.59 15.96 318
Al-Harthy et al. (2003) CKD 3 63.80 15.80 3.60 2.80 1.90 1.70 0.30 3.00 2.27 1.10 N.R. N.R. N.R.
Udoeyo and Hyee (2002) CKD 4 52.72 2.16 1.09 0.54 0.68 0.05 N.R. 0.11 0.33 N.R. N.R. 42.39 N.R.
Wang et.al. (2002)
Konsta-Gdoutos et al. (2001) CKD 5 56.99 17.67 5.06 2.75 0.91 6.55 0.30 3.43 2.56 0.38 N.R. 8.00 N.R.
Shoaib et al. (2000) CKD 6 49.75 11.95 1.12 2.45 1.86 6.35 3.87 2.66 5.62 6.80 N.R. 17.92 N.R.
Dyer et al. (1999) CKD 7 34.30 34.30 3.50 2.00 0.80 11.40 1.20 8.20 6.60 8.10 0.00 N.R. N.R.
Dyer et al. (1999) CKD 8 34.80 12.20 3.20 1.80 0.90 10.60 1.60 7.50 6.54 2.80 1.40 N.R. N.R.
Batis et al. (1996) CKD 9 43.95 10.12 4.07 2.89 0.95 0.27 0.18 0.82 0.72 0.38 N.R. N.R. N.R.
Batis et al. (1996) CKD 10 42.59 13.68 4.36 2.30 1.23 0.10 0.28 0.79 0.80 0.17 N.R. N.R. N.R.
El-Sayed et al. (1991) CKD 11 48.80 13.00 3.33 2.00 2.02 8.70 4.19 2.73 5.99 7.40 18.57 12.59 N.R.
Wang and Ramakrishnan
(1990) Ramakrishnan and Balaguru
(1987) CKD 12 45.71 15.78 3.95 1.09 0.98 2.32 N.R. N.R. N.R. N.R. N.R. N.R. N.R. Ramakrishnan
(1986)
Bhatty (1984-1986) CKD 13 49.30 14.70 3.31 2.04 1.03 3.07 0.23 2.60 1.94 0.24 10.43 23.43 511
Bhatty (1984-1986) CKD 14 51.70 15.50 3.84 2.13 1.59 11.10 0.22 2.50 1.87 0.26 21.72 10.50 489
Bhatty (1984-1986) CKD 15 41.90 15.40 2.65 1.51 1.35 0.25 0.23 4.90 3.45 3.47 3.00 34.06 439
Bhatty (1984, 1985b) CKD 16 41.70 14.00 2.85 1.51 2.73 5.55 0.27 3.60 2.64 0.29 4.31 27.81 566
Bhatty (1984) CKD 17 44.50 16.50 3.71 1.79 1.43 5.67 0.31 3.50 2.61 0.15 7.46 21.33 718
Ravindrarajah (1982) CKD 18 42.70 12.20 5.80 2.30 1.30 6.50 0.80 4.30 3.63 N.R. 6.10 22.10 528
#
samples 18 18 18 18 18 18 16 17 17 15 10 12 7
Average 46.53 14.75 3.50 2.06 1.37 4.94 1.32 3.30 3.43 3.06 7.56 20.99 510
St. Dev. 7.23 5.99 1.15 0.63 0.54 3.82 1.54 2.11 2.10 3.29 7.33 9.97 122
* CKDs are numbered as they are referred to in subsequent discussion N.R. = Not Reported; Na2Oe = 0.658 x K2O + Na2O fCaO = free calcium oxide (free lime) and calcium hydroxide LOI = Loss on Ignition
65
Table 2.12 Chemical and physical composition of PC: from CKD-PC literature review
CaO SiO2 Al2O3 Fe2O3 MgO SO3 Na2O K2O Na2Oe fCaO LOI Blaine Author Material* Type % % % % % % % % % % % m2/kg
Maslehuddin et al. (2008b) PC 1 TI 64.35 22.0 5.64 3.80 2.11 2.10 0.19 0.36 0.33 N.R. 0.7 N.R.
Maslehuddin et al. (2008b) PC 2 TV 64.07 20.52 4.08 4.24 2.21 1.96 0.21 0.31 0.41 N.R. 0.8 N.R.
Maslehuddin et al. (2008a) PC 3 TI N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R.
El-Aleem et al. (2005) PC 4 TI 64.00 21.06 5.43 3.41 0.75 2.48 0.10 0.12 0.18 0.22 2.42 300
Al-Harthy et al. (2003) PC 5 TI 62.50 20.60 4.50 3.60 2.60 2.70 0.20 0.50 0.53 N.R. N.R. N.R.
Udoeyo and Hyee (2002) PC 6 TI N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R.
Wang et. al. (2002)
Konsta-Gdoutos et al. (2001) PC 7 TI 64.29 20.35 5.24 3.58 1.13 2.56 0.11 0.60 0.50 N.R. 1.10 N.R.
Shoaib et al. (2000) PC 8 TI 62.70 21.42 3.30 5.23 2.40 2.35 2.41 0.45 2.71 N.R. 1.22 N.R.
Dyer et al. (1999) PC 9 TI 64.90 21.10 5.00 2.70 1.60 3.30 0.30 0.60 0.69 N.R. N.R. N.R.
Batis et al. (1996) PC 10 TI 65.50 20.54 4.74 3.74 1.52 2.61 0.10 0.48 0.42 N.R. N.R. N.R.
El-Sayed et al. (1991) PC 11 TI 62.66 20.40 5.19 3.26 2.62 2.37 2.48 0.32 2.69 0.30 1.17 366
Wang and Ramakrishnan
(1990) PC 12 TIII 63.05 20.98 6.13 2.61 1.39 2.50 N.R. N.R. N.R. 0.43 N.R. 540 Ramakrishnan and Balaguru (1987) PC 13 TII N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R.
Ramakrishnan and Balaguru (1987) PC 14 TIII N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R. N.R.
Ramakrishnan and Balaguru (1987)
Ramakrishnan (1986) PC 15 TI 70.27 19.93 1.83 3.03 1.93 2.58 N.R. 0.90 N.R. N.R. N.R. N.R.
Bhatty (1985a & 1986) PC 16 TI 64.60 21.40 5.10 3.50 2.10 1.70 0.23 0.46 0.53 0.70 1.10 326
Bhatty (1984, 1985b) PC 17 TI 63.85 20.16 4.75 2.51 1.46 3.93 0.10 0.47 0.41 0.78 2.13 441
Bhatty (1984, 1985b) PC 18 TI 63.33 21.10 4.90 2.57 2.08 2.78 0.15 0.83 0.70 0.93 1.05 398
Bhatty (1984, 1985b) PC 19 TI 63.02 24.06 4.20 2.68 2.29 2.51 0.15 0.39 0.41 0.60 0.71 313
Bhatty (1984, 1985b) PC 20 TI 62.66 21.12 4.42 2.05 3.95 2.78 0.16 0.93 0.77 0.88 1.74 438
Bhatty (1984) PC 21 TI 64.59 21.44 3.93 2.74 1.81 3.48 0.13 0.35 0.36 0.93 1.47 417
Ravindrarajah (1982) PC 22 TI 63.00 20.00 6.00 3.00 1.50 2.00 N.R. N.R. 1.00 0.00 2.00 N.R.
#
samples+ 16 16 16 16 16 16 14 15 15 9 12 8
Average+ 64.14 21.04 4.64 3.21 1.99 2.64 0.49 0.52 0.82 0.59 1.40 375
St. Dev. + 1.88 1.00 1.00 0.74 0.74 0.56 0.83 0.22 0.79 0.34 0.56 57
* PCs are numbered as they are referred to in subsequent discussion N.R. = Not Reported; Na2Oe = 0.658 x K2O + Na2O fCaO = free calcium oxide (free lime) and calcium hydroxide LOI = Loss on Ignition + only includes TI cements (PC 2, PC 12, PC 13, and PC 14 were excluded).
66
2.5.1.2 CKD-PC Mineralogical Composition
In the majority of studies, CKD mineralogical composition data is rarely reported. The
composition of a CKD consists of unreacted phases from the raw material, partially
calcined raw feed, condensed volatiles (alkalis, chlorides, and sulfates), and/or PC clinker
particles. Since CKDs are a by-product resulting from the partial decarbonation of
limestone (CaCO3), either free lime (free CaO) or calcite is expected to be the
predominant mineralogical component. Calcium carbonate is an important mineralogical
component of CKDs that can affect CKD-PC blend properties (Bhatty, 1985a). The
reported mineralogical composition data of CKD in the literature is shown in Table 2.13.
Although there are only eight data points for calcite content, the standard deviation
reflects its variability in CKDs.
Dyer et al. (1999) used Rietveld Refinement on X-ray diffraction traces over an angular
range of 3° to 80° 2θ using commercially available software program to estimate
proportions of the compounds present in CKDs 7 and 8; this is shown in Table 2.13. This
analysis, however, cannot be used as an estimate of the actual amount of the compounds
in the CKDs due to the lack of consideration for the amorphous content. Also, CKD 7
appears to be out of the ordinary since the free calcium oxide content is 0%.
As stated in the previous section, the CKD chemical components that can affect
properties of CKD-PC blends are alkalis, sulfates, chlorides, and free lime (Bhatty,
1985a). The chemical composition, however, is not the only important factor to consider
in assessing the potential impact of using a CKD-PC blend. The physical form of these
chemical components can also be significant. For example, alkalis are known to impact
cement properties, but can behave very differently if present in different forms. Readily
soluble alkali (alkali chlorides and alkali sulfates) can impact early hydration of PC much
more significantly than alkali found in crystal structures that are less soluble. Further,
alkali chlorides and alkali sulfates impact the hydration of PC differently.
67
Table 2.13 Mineralogical composition of CKD: from CKD-PC literature review
Mineralogical Phase CKD 2 CKD 7 CKD 8 CKD 13 CKD 14 CKD 15 CKD 16 CKD 17 Avg. St.Dev.
CaCO3 (calcite) + 8.9 52.8 50.94 22.65 60.4 44.58 64.68 43.56 20.45
CaO (free calcium oxide) + 0.0 1.4 + + + + +
Ca(OH)2 (portlandite) + 26.5 8.4
CaSO4 (anhydrite) + 9.8 6.1 + + + +
SiO2 (quartz) + 3.5 6.9 + + + + + Na2SO4
(thenardite) 7.9 0.0 Ca2Al(OH)6Cl2(H2O)2
(Friedel’s salt) 3.1 0.0 Na0.31K0.69Cl
(halite, potassium) + 0.0 2.9 K3Na(SO4)2 (aphthitalite) 0.0 10.2 +
K2Al4(Si6Al2O20)(OH)4 (Muscovite 2m1) 0.0 3.3
Ca2Si12Al4O32(H2O)12 (calcium harmotome) 0.0 0.9
KCl (sylvite) 20.4 7.0 +
K2Ca(SO4).H2O (syngenite) 19.9 0.0
K2SO4 (arcanite) 0.0 0.0 + + + + alpha C2S
(belite) + 0.0 0.0 CKD 2: El-Aleem (2005); CKD 7-8: Dyer (1999); CKD 13-15: Bhatty (1986), Bhatty (1985b), Bhatty (1985a), and Bhatty (1984); CKD 16: Bhatty (1985b) and Bhatty (1984); CKD 17: Bhatty (1984).
+: means it was identified as a component
68
2.5.1.3 CKD-PC Physical Composition
The majority of CKD-PC interaction studies do not report the physical characteristics of
the materials used. For the studies that did describe the physical properties of the
materials, the characterization methods consisted of Blaine fineness, particle size
distribution, percentage passing sieve, and density. Blaine fineness was the most
prominent method used to characterize the fineness of CKDs and PC, which is presented
in Table 2.11 and Table 2.12.
The range of the seven reported CKD Blaine fineness values is between 318 m2/kg and
718 m2/kg. The average Blaine fineness value of the 7 CKDs (510 m2/kg) is higher than
the average range of the PCs used in the same research studies (375 m2/kg). The standard
variation of the Blaine fineness for CKDs (122 m2/kg) is also higher in comparison to the
standard variation of Blaine fineness values for PC (57 m2/kg), as Blaine fineness in PC
is a process control parameter. The Blaine fineness values reported in the literature have
led some researchers to conclude that CKDs are finer than PC.
Wang et al. (2002) and Konsta-Gdoutos et al. (2001) were the only authors to have
provided particle size distribution analyses for the materials used in their CKD-PC
interaction study. CKD 5 and PC 7 particle size distributions are shown in Figure 2.14
(slag was also used in their research study and is included in the figure). Based upon the
particle size distribution curve, Wang et al. (2002) concluded that CKD 5 is coarser than
PC 7.
Ramakrishnan and Balaguru (1987) reported CKD 12 to be 98.56% passing a No. 200
sieve (70 µm), which is higher than each reported percentage passing a No. 200 sieve for
the three cements used in this research study (PC 13 = 95.20%, PC 14 = 97.90%, PC 15 =
95.50%). Based upon the 75 µm (No. 200 sieve), CKD 12 is finer than PC 14. The
density values are reported for CKD 4 (Udoeyo and Hyee, 2002) and CKD 18
69
(Ravindrarajah, 1982), which are 2.65 and 2.72 respectively. PC specific density is
generally accepted to be 3.15, although it generally varies between 3.1 and 3.2.
Figure 2.14 Particle size distribution of CKD 5 and PC 7 (Wang et al., 2002)
2.5.2 Workability
Maslehuddin et al. (2008a) studied the effect of replacing PC 3 with CKD 1 at 0%, 5%,
and 10% replacement by mass in pastes. The water required to maintain normal
consistency (ASTM C187) of PC alone was at a water to binder ratio (w/b) of 24.6%. The
w/b marginally increased to 24.9% at both 5% and 10% CKD replacement. Therefore, the
use of CKD 1 at up to 10% replacement of PC 3 did not significantly change the water
requirement.
El-Aleem et al. (2005) studied the workability effect of replacing PC 4 with CKD 2 at
0%, 2%, 4%, 6%, 8%, and 10% replacement by mass in pastes and mortars. The authors
observed that the addition of CKD increased the water required to maintain normal
consistency of pastes and constant flow of mortars (ASTM C1437), as shown in Figure
2.15 and Figure 2.16, respectively. As the amount of PC replacement with CKD
70
increased, the water demand also increased in both pastes and mortars. For the pastes, the
w/b increased almost linearly from 26.5% with no CKD replacement to 29.5% at 10%
CKD replacement of PC. For the mortars, the w/b also increased somewhat linearly from
0.485 with no CKD replacement of PC to 0.595 at 10% CKD replacement of PC.
El-Aleem et al. (2005) suggested that the increased water demand may be attributed to
the high amounts of alkalis, sulfates and volatile salts, and free lime in CKD 2 in
comparison to PC 4. El-Aleem et al. (2005) also mentioned that the slightly higher
surface area (Blaine fineness value) of CKD 2 could be a factor in the increased water
demand of pastes.
Figure 2.15 Paste water/binder ratio, initial set, and final set of CKD 2 as a partial
substitute of PC 4 at different levels of replacement (El-Aleem et al., 2005)
71
0.45
0.50
0.55
0 .60
0 2 4 6 8 10
CKD Replacement of PC, %
Wa
ter
/ b
ind
er
Figure 2.16 Mortar water/binder ratio of CKD 2 as a partial substitute of PC 4 at different
levels of replacement (El-Aleem et al., 2005)
Al-Harthy et al. (2003) determined the water demand of mortar mixes to maintain the
same workability using CKD 3 at a 0%, 10%, 20%, 25%, and 30% replacement level of
PC 5, as shown in Figure 2.17. As the level of CKD 3 replacement increased in the
mortar mixes, the water demand also increased. The w/b increased almost linearly from
0.644 with no CKD to 0.677 at 10% CKD replacement of PC and 0.759 at 25%
replacement. At 30% replacement, however, the water requirement decreased to w/b of
0.731. Al-Harthy et al. (2003) stated that the increased cohesiveness of the mortar mixes
is caused by the very fine particles of CKD. It is not clear whether the sudden w/b
decrease as the CKD increased from 25% to 30% replacement is caused by a chemical or
physical effect. Al-Harthy et al. (2003) also reported the workability effect using 0%, 5%,
10%, 15%, 20%, 25%, and 30% CKD 3 replacement by total mass of PC 5 in concrete
mixtures. Three w/b ratios of 0.50, 0.60, and 0.70 were used for each concrete mixture.
For each level of w/b ratio, the measured slump was the same or it decreased as the
amount of CKD replacement level increased. As the w/b ratio increased, the impact of
CKD 3 replacement of PC 5 on slump loss became more significant.
72
0 .60
0.65
0.70
0.75
0 .80
0 10 20 25 30
CKD Replacement of PC, %
Wa
ter
/ b
ind
er
Figure 2.17 Mortar water/binder ratio of CKD 3 as a partial substitute of PC 5 at different
levels of replacement (Al-Harthy et al., 2003)
Udoeyo and Hyee (2002) studied the workability effect of CKD 4 substitution at 0%,
20%, 40%, 60%, and 80% of PC 6 in concrete mixes. Each concrete mix was batched
according to the mix ratio of 1:3:4:0.65 (binder: sand: coarse aggregate: water). The
results show that as the CKD replacement level increases, the measured slump decreases.
Udoeyo and Hyee (2002) did not suggest mechanisms for the loss of slump in the CKD-
PC concrete mixes.
Wang et al. (2002) conducted viscosity tests on pastes with CKD 5 at partial replacement
levels of PC 7 at 0%, 15%, 25%, and 50% with a w/b ratio of 0.50. They further reported
that the viscosity of the pastes, measured using a rheometer with coaxial cylinders,
increased as the amount of CKD used to replace the cement increased. Wang et al.
(2002) suggested three factors that could contribute to increased viscosity. First, CKD 5
is coarser than PC 7, based upon the particle size distribution comparison shown in
Figure 2.10 and is, therefore, increasingly viscous. The authors state that coarse particles
73
can behave independently of colloidal particles and act as amplifiers that increase the
viscosity of a concentrated suspension system, such as fresh cement paste. The authors
cited research conducted by Sengun and Probstein (1997) that used bimodal suspensions
containing both colloidal and noncolloidal size particles, where a particle size ratio
typically larger than 10 is treated as bimodal. It should be noted, however, that the fine
and coarse fraction of a CKD generally has only a small fraction of the particle size ratio
greater than 10. Second, there is an increase in rapid ion dissolution during the early
stages of hydration due to the presence of CKD, which may result in high viscosity.
Third, the size irregularity of CKD particles may increase friction between the cement
and CKD particles when compared to paste with cement particles only.
Wang and Ramakrishnan (1990) investigated the workability of pastes and concrete made
with a binary blend consisting of 5% CKD (CKD 12) and 95% TIII cement (PC 12). The
normal consistency w/b ratio for the plain cement paste was 27.0% and the paste with
CKD 12 had a w/b ratio of 28.0%. Although the water content required for normal
consistency was 1% higher, the authors did not believe this necessarily meant that the
CKD-PC blend needed a higher water content to produce the same concrete slump as a
plain cement. Wang and Ramakrishnan (1990) stated that the Vicat paste test measures
viscosity whereas the concrete slump test indicates the lubricating ability of the paste.
The concrete mixes were tested at three w/b ratios: 0.45, 0.52, and 0.55. Wang and
Ramakrishnan (1990) reported there was no significant difference in the slump between
the plain and CKD blended concretes.
Ramakrishnan (1986) investigated the workability of pastes and concrete made with a
binary blend consisting of 5% CKD (CKD 12) and 95% TI cement (PC 15). The w/b
ratio for the plain cement paste was 0.245 and the paste with CKD 12 had a w/b ratio of
0.255. The CKD-PC blend had 1% higher normal consistency than the plain cement. The
concrete mixes were tested at a cement content of 386 kg/m3 and w/b ratio of 0.45. Six
74
sets of each concrete mix were batched. Ramakrishnan (1990) reported there was no
significant difference in the slump between the plain and CKD blended concretes.
Bhatty (1985a) used a TI cement (PC 16) with three different CKDs (CKD 13, CKD 14,
and CKD 15) to investigate their effect on paste workability. CKD-PC blends were
prepared by replacing 0%, 10%, and 20% of cement at a w/b ratio of 0.45. Workability
was determined by the size of a mini-slump pat area and was consistently reduced for
blends with CKD compared to the control pastes. Although the workability of all CKD-
PC blends decreased as the amount of CKD increased from 10% to 20%, the magnitude
varied significantly.
Bhatty (1984) also conducted mini-slump pat area studies on pastes using five companion
cements and CKD obtained from five different cement plants. The five companion
cement kiln dust blends were: PC 17 and CKD 13, PC 18 and CKD 14, PC 19 and CKD
15, PC 20 and CKD 16, and PC 21 and CKD 17. For each CKD-PC blend, the CKD
replacement of the cement was 0%, 10%, 15%, and 20% by mass at a w/b ratio of 0.50.
As the percentage of CKD replacement increased, the blends containing CKD 13, CKD
14, CKD 16, and CKD 17 generally decreased workability. The opposite trend was
observed for blends with CKD 15. Bhatty (1984) stated that as the amount of high
chloride from the CKD increased in the CKD blends, workability also increased.
Ravindrarajah (1982) used pastes and concrete to study the workability effect of CKD-PC
interaction. For pastes, CKD 18 was used as a partial cement replacement of PC 22 by
mass at 0%, 25%, 50%, 75%, and 100%. Water was added to each paste mix to maintain
a standard consistency. The author reported that as the percentage of CKD increased in
the cement paste, the amount of water had to increase in order to attain a normal
consistency. For concrete, CKD 18 was used as a partial cement replacement of PC 22 by
mass at 0%, 15%, 25%, 35%, and 45%. Water was added to each concrete mix to
maintain the same slump for all concrete mixes. Similar to pastes, Ravindrarajah (1982)
75
determined that as the CKD percentage increased in the concrete mix, the water demand
to maintain the same slump also increased. The author attributed the increased water
demand in pastes and concrete to the higher surface area (Blaine fineness) of the kiln dust
compared to cement and the increased solid volume of the mix (since the density of CKD
is lower than that of cement).
A summary of the studies conducted on the workability effects of CKD-PC blends
compared to each of the respective reference plain cements is shown in Table 2.14. The
majority of researchers found that the workability was reduced as the amount of CKD
increased, and that the trend was somewhat linear until a plateau was reached. The
suggested reasons for a reduction in workability when CKD is used as a partial substitute
for PC vary considerably: CKD alkali content, chloride content, sulfate and volatile salts
content, lime content, a high fineness of CKD, rapid ion dissolution, high coarseness of
CKD, particle size, and lower density of CKD. It is interesting to note that both higher
fineness (based upon Blaine fineness) and higher coarseness (based upon particle size
distribution) of CKD compared to cement were suggested to have the same impact of
reducing workability of pastes. The researcher with the only CKD-PC blend that
increased workability stated that as the amount of high chloride from the CKD increased
in the CKD blends, workability also increased. Chlorides, however, are not widely
known to impact workability (refer to 2.4.7).
76
Table 2.14 Workability: from CKD-PC literature review
Author(s)
Blend Type w/b % CKD Replacement
General Effect on
Workability
Author Suggested Mechanism(s)
Maslehuddin et al. (2008a)
CKD 1/PC 3 P V 0,5,10 N.C.
El-Aleem et al. (2005)
CKD 2/PC 4 P M
V V
0,2,4,6,8,10 0,2,4,6,8,10
↓
↓
(1) Higher amounts of alkalis, sulfates and volatile salts, and lime in CKD.
(2) Higher Blaine fineness in CKD.
Al-Harthy et al. (2003)
CKD 3/PC 5 M C
V K
0,10,20,25,30 0,10,20,25,30
↓
↓
(3) Increased cohesiveness caused by very fine CKD particles in pastes.
(4) Impact of CKD replacement in concrete was more dramatic at higher w/b ratios.
Udoeyo and Hyee (2002)
CKD 4/PC 6 C 0.65 0,20,40,60,80 ↓
Wang et al. (2002)
CKD 5/PC 7 P 0.50 0,15,25,50 ↓ (5) CKD coarseness increases viscosity.
(6) Rapid ion dissolution due to presence of CKD.
(7) CKD particle size irregularity
Wang and Ramakrishnan (1990)
CKD 12/PC 12 P C
V 0.45
0,5 0,5
↓ N.C.
Ramakrishnan (1986)
CKD 12/PC 15 P C
V 0.45
0,5 0,5
↓ N.C.
Bhatty (1985a)
CKD 13/PC 16 CKD 14/PC 16 CKD 15/PC 16
P P P
0.45 0.45 0.45
0,10,20 0,10,20 0,10,20
↓ ↓ ↓
Bhatty (1984)
CKD 13/PC 17 CKD 14/PC 18 CKD 15/PC 19 CKD 16/PC 20 CKD 17/PC 21
P P P P P
0.50 0.50 0.50 0.50 0.50
0,10,15,20 0,10,15,20 0,10,15,20 0,10,15,20 0,10,15,20
↓ ↓ ↑ ↓ ↓
(8) As the amount of high chloride from the CKD increased in the CKD blends, workability also increased.
Ravindrarajah (1982)
CKD 18/PC 22 P C
V V
0,25,50,75,100 0,15,25,35,45
↓ ↓
(9) Higher fineness of the CKD in comparison to the PC
(10) Increased solid volume (since the density of the CKD is lower than that of the cement).
P = Paste; M = Mortar; C = Concrete. V = varied the w/b ratio to maintain consistent workability K = constant w/b ratio, but more than one w/b ratio was tested. N.C. = No Change
77
2.5.3 Setting Time
Maslehuddin et al. (2008a) studied the setting time effect of replacing PC 3 with CKD 1
at 0%, 5%, and 10% replacement by mass in pastes, with water added to maintain a
constant normal consistency according to ASTM C187 and ASTM C191. The plain
cement paste had an initial setting time of 175 minutes and a final setting time of 256
minutes. The initial and final setting times of the paste with 5% CKD replacement were
10 minutes (6%) and 6 minutes (2%) faster than the control plain cement, respectively.
The initial and final setting times of the paste with 10% CKD replacement were 20
minutes (11%) and 18 minutes (7%) faster than the control plain cement, respectively.
The authors attributed the decrease in both initial and final setting times to the high
amounts of lime and alkalis in the CKD, which accelerate the hydration process leading
to faster setting times.
El-Aleem et al. (2005) studied the set time effect of replacing PC 4 with CKD 2 at 0%,
2%, 4%, 6%, 8%, and 10% replacement by mass in pastes, with water added to maintain
a constant normal consistency. El-Aleem et al. (2005) reported that as the CKD
replacement increases, the water demand increases and the setting time decreases. This is
contrary to what many expect since it is well known that an increase in w/b results in
longer settings times for a given paste. It is important to note that the established
influence of w/b refers to its effect on a single blend and not on blends with different
chemical/mineralogical and physical properties. As shown in Figure 2.15, the decrease of
both initial and final setting times is almost linear as a function of CKD replacement. The
initial set time decreased from approximately 135 minutes with no CKD to approximately
65 minutes with 10% CKD replacement of PC. The final set time decreased from
approximately 230 minutes with no CKD to approximately 110 minutes with 10% CKD
replacement of PC. Similar to Maslehuddin et al. (2008a), El-Aleem et al. (2005)
suggested that this was due to the high amounts of lime and alkalis in CKD.
78
Udoeyo and Hyee (2002) studied the setting time effect of replacing PC 6 with CKD 4 at
20%, 40%, 60%, and 80% replacement by mass in concrete at a w/b ratio of 0.65.
Udoeyo and Hyee (2002) reported that at a 20% CKD 4 replacement level of PC 6, the
initial setting time increased slightly from 0.72 h to 0.78 h, and the final set time
remained unchanged at 1.62 h. As the CKD 4 content increased beyond 20%
replacement, the set time increased significantly. At a very high replacement level of
80%, the initial set time was 1.33 h and final set time was 2.5 h. Udoeyo and Hyee (2002)
stated that the values of the initial and final setting times were within the relevant BS and
ASTM standards, but did not suggest possible mechanisms for the increased setting
times.
Wang and Ramakrishnan (1990) used CKD 12 at 5% cement replacement of a TIII
cement (PC 12) to determine the impact on paste and concrete setting time. The normal
consistency w/b ratio for the plain cement paste was 27.0% and the paste with CKD 11
had a w/b ratio of 28.0%. The plain cement paste had an initial setting time of 122
minutes and a final setting time of 155 minutes. The CKD-PC blend initial and final
setting times were 45 minutes (38%) and 53 minutes (34%) longer than the control plain
cement, respectively. Wang and Ramakrishnan (1990) attributed the longer setting times
of the CKD paste to the higher water content required to maintain normal consistency.
The concrete mixes were tested at three w/b ratios: 0.45, 0.52, and 0.55. The effects of
CKD on the initial and final setting times of concrete were determined by concrete
penetration resistance (ASTM C403). Both the initial and final set of the CKD-PC
concrete occurred 30 minutes later than for plain concrete (the w/b ratio for the concrete
mixes used to assess setting times was not specified). Wang and Ramakrishnan (1990)
did not suggest possible mechanisms for the increase in concrete setting times.
Ramakrishnan (1986) used CKD 12 at 5% cement replacement of a Type I cement (PC
15) to determine the impact on paste (ASTM C191) and concrete setting time (ASTM
C403). The w/b ratio for the plain cement paste was 24.5% and the paste with CKD 12
79
had a w/b ratio of 25.5%. Ramakrishnan (1986) stated that the initial and final setting
times of the CKD-PC blend were longer than that of the plain cement. The author
reported the differences to be 22 minutes and 40 minutes, respectively, for initial and
final setting times. The concrete mixes were tested at a cement content of 386 kg/m3 and
w/b ratio of 0.45. Six sets of each concrete mix were batched. Ramakrishnan (1986)
reported the initial and final setting time for one of the six concrete mixes for each of the
CKD blend and plain cement. The initial and final setting times for the plain cement
concrete mix was 5 hours and 42 minutes and 7 hours and 20 minutes, respectively. The
initial and final setting times for the concrete mix with CKD 12 were 6 hours and 4
minutes and 7 hours and 48 minutes, respectively. Ramakrishnan (1986) concluded that
the setting time of the CKD pastes was slightly longer than the plain cement paste, but
the setting time of the CKD concrete mix and plain concrete mix were almost the same
(within 5%). It is important to note, however, that the concrete initial and final setting
times of the CKD concrete mixes were 22 minutes and 28 minutes, respectively, longer
than the plain concrete mix.
Bhatty (1985a) used a TI cement (PC 16) with three different CKDs (CKD 13, CKD 14,
and CKD 15) to investigate their effect on paste set time. Cement and CKD blends were
prepared by replacing 0%, 10%, and 20% of cement at a w/b ratio of 0.45. Bhatty (1985a)
stated that time of initial set was always shorter compared to cement for any blends
containing 10% CKD. Longer time of initial set was obtained for blends made with 20%
CKD 13 and 20% CKD 15, as compared to blends made with 10% of CKD 13 and 10%
of CKD 15 or to cement alone. The blend made with 20% of CKD 14 had a considerably
shorter time of initial set when compared to all other CKD blends and cement alone.
CKD 14 is characterized by high sulfate (11.10%), high free lime (21.72%), and low
chloride (0.26%) contents.
Bhatty (1984) also conducted setting time tests on pastes using five companion cements
and dusts obtained from five different cement plants. The five companion cement kiln
80
dust blends are: PC 17 and CKD 13, PC 18 and CKD 14, PC 19 and CKD 15, PC 20 and
CKD 16, and PC 21 and CKD 17. For each cement kiln dust blend, the CKD replacement
of the cement was 0%, 10%, 15%, and 20% at a w/b ratio of 0.50. As the CKD
replacement level increased, the setting time for blends with CKD 13, CKD 14, CKD 16,
and CKD 17 decreased. Blends with CKD 15 had the opposite effect and increased
setting time. Bhatty (1984) concluded that the time of set generally decreased with
increased dust addition levels, although no effects of CKD chemistry were specified.
Ravindrarajah (1982) used cement pastes to assess the set time of partial and complete
replacement of cement with CKD 18 and PC 22. Cement was partially replaced by mass
at 0%, 25%, 50%, 75%, and 100%. The pastes were mixed with necessary water content
to produce a consistent workability. As the percentage of cement replacement increased,
the final setting time increased. The data shows that all samples had set within 10 hours,
which was the specified limit in the British Standard. The initial setting time also
lengthened, but the rate of increase slowed after 50% of cement had been replaced by
CKD. Ravindrarajah (1982) stated that the increased set times are opposite to what is
expected with CKDs, since a higher alkali concentration promotes shortened setting
times. The author suggested the effect of increased set time may be attributed to (i) the
physical presence of inactive particles and (ii) the kiln dust that acted as a barrier between
the cement particles and water. The nature of the suggested barrier was not specified by
the author.
A summary of the studies conducted on the setting time effects of CKD-PC blends
compared to each of the respective reference plain cement is shown in Table 2.15. The
effect of CKDs on setting times is decidedly mixed. The same CKD at different
replacement levels of a PC can have different effects on setting time. The setting time
impact of CKD is likely a function of the total composition of the CKD-PC blend.
81
Table 2.15 Setting time: from CKD-PC literature review
Author(s)
Blend Type w/b % CKD Replacement
General Effect on Setting
Time
Author Suggested Mechanism(s)
Maslehuddin et al. (2008a)
CKD 1/PC 3 P V 0,5,10 ↓
(1) High amounts of lime and alkalis in CKD accelerate hydration and lead to fast setting.
El-Aleem et al. (2005)
CKD 2/PC 4 P
V
0,2,4,6,8,10
↓
(2) High amounts of lime and alkalis in CKD accelerate hydration and lead to fast setting.
Udoeyo and Hyee (2002)
CKD 4/PC 6 C 0.65 0,20,40,60,80 ↑
Wang and Ramakrishnan (1990)
CKD 12/PC 12 P C
V N.R.
0,5 0,5
↑ ↑
(3) Higher set times in paste attributed to higher water demand due to the CKD.
Ramakrishnan (1986)
CKD 12/PC 15 P C
V 0.45
0,5 0,5
↑ N.C.
Bhatty (1985a)
CKD 13/PC 16 CKD 14/PC 16 CKD 15/PC 16
P P P
0.45 0.45 0.45
0,10,20 0,10,20 0,10,20
10% ↓; 20% ↑ 10% ↓; 20% ↓ 10% ↓; 20% ↑
Bhatty (1984)
CKD 13/PC 17 CKD 14/PC 18 CKD 15/PC 19 CKD 16/PC 20 CKD 17/PC 21
P P P P P
0.50 0.50 0.50 0.50 0.50
0,10,15,20 0,10,15,20 0,10,15,20 0,10,15,20 0,10,15,20
↓ ↓ ↑ ↓ ↓
Ravindrarajah (1982)
CKD 18/PC 22 P C
V V 0,25,50,75,100
0,15,25,35,45
↑ ↑
(1) Physical presence of inactive particles in the kiln dust.
(2) The dust may act as a barrier between the cement particles and water.
P = Paste; M = Mortar; C = Concrete. V = varied w/b ratio to maintain consistent workability K = constant w/b ratio, but more than one w/b ratio was tested. N.C. = No Change
82
2.5.4 Hydration Kinetics
El-Aleem et al. (2005) studied the hydration behavior effect of replacing PC 4 with CKD
2 at 0%, 2%, 4%, 6%, 8%, and 10% replacement by mass in pastes with water added to
maintain a constant normal consistency. El-Aleem et al. (2005) assessed the hydration
behaviour of each mix by determining the free lime as well as evaporable water and
chemically combined water contents at 3, 7, 28, and 90 days, as shown in Figure 2.18.
The free lime was determined using the alcohol ammonium acetate method, which does
not distinguish between calcium oxide and calcium hydroxide. The evaporable water
content of the hardened paste was determined by subtracting the total water content (loss
on ignition at 1000°C of the saturated sample) from the combined water content (loss on
ignition at 1000°C for 2 hours). The authors reported that the quantity of free lime
increased with curing time due to the continuous hydration of the main cement phases
and leaching from CKD 2.
El-Aleem et al. (2005) also noted that at any given time, the quantity of free lime
increased with CKD 2 content in the blend. Continuous hydration of the cement phases
led to a decrease in evaporable water. It was reported that the evaporable water content in
pastes increased with the CKD 2 content due to the increase in mixing water and low or
no hydraulic properties of CKD 2, in comparison to the high hydraulic cement properties
of PC 4. Generally, the hydration and accumulation of hydration products mainly as
calcium silicate and sulfoaluminate hydrates cause the chemically combined water
content to decrease. The cement pastes with CKD 2 and PC 4 exhibited lower values of
combined water content than the control PC 4 paste. This indicated to the authors that the
C-S-H formed in the blends with CKD 2 and PC 4 blend is lower than that in PC 4 alone.
83
(a)
(b)
(c)
Figure 2.18 Hydration of pastes showing (a) evaporable water content (%), (b) free lime
content (%) (calcium oxide and calcium hydroxide), and (c) chemically combined water
content, as a function of time at different percentage levels of PC 4 replacement with
CKD 2 (El-Aleem et al., 2005)
I.1 Control I.2 2% CKD I.3 4% CKD I.4 6% CKD I.5 8% CKD
I.6 10% CKD
84
Wang et al. (2002) conducted hydration tests on pastes with CKD 5 at partial replacement
levels of PC 7 at 0%, 15%, 25%, and 50% with a w/b ratio of 0.50 using adiabatic
calorimetric tests. Wang et al. (2002) reported that during initial hydrolysis the pastes
with partial replacement of PC 7 with CKD 5 had a much higher heat of evolution than
the pastes with PC 7 alone. The induction period began and ended much later than for the
pastes with cement alone. The authors suggested that both of these characteristics may be
due to the high alkali content of the CKD, which may accelerate ion dissolution of the
silicates in the binder system resulting in a high initial heat evolution and an extended ion
dissolution period. The cement paste with 15% CKD and 85% cement produced a higher
heat peak value for rate of heat evolution than the paste with cement alone. The authors
stated this higher value generally reflects the hydration of C3S and C2S in PC and implied
that the binder system may have an optimum alkali to silicate ratio. They stated that the
alkalis, mainly from the CKD, may facilitate dissolution of the silicates and accelerate the
formation of calcium silicate hydrates (C-S-H). The paste with 25% CKD and 75% PC,
however, had a lower heat peak value for rate of heat evolution than the paste with 15%
CKD and 85% cement. Wang et al. (2002) reported that as the percentage of cement
replaced with CKD increased, the heat evolution decreased when the CKD content was
greater than a certain proportion. Additionally, excessive amounts of alkalis in the paste
may have depressed dissolution and retarded hydration of the silicates. The peak
appearance of the 25% CKD paste was delayed when compared to the 15% CKD paste
and plain cement paste. Wang et al. (2002) concluded that for a specified CKD content,
the peak rate of heat evolution increased as the alkali:silica ratio in the paste also
increased. The high peak rate of heat evolution generally indicates early strength
development.
Dyer et al. (1999) studied the hydration chemistry of cement pastes using two CKDs
(CKD 7 and CKD 8) and one cement (PC 9). Dyer et al. (1999) used isothermal
conduction calorimetry to assess the maximum rate heat evolution and the time at which
this peak occurs at 0%, 20%, 35%, 50%, and 75% CKD replacement of PC. The w/b ratio
85
was 0.50 for each paste. The results from the magnitude of the maximum heat rate
evolution indicated that both types of CKD accelerated the hydration of cement. The
results for the time at which the peak occurred, however, indicated that the CKDs had the
effect of slowing hydration. Dyer et al. (1999) suggested two possible reasons for the
conflicting results. First, the combination of potassium chloride (which accelerates
hydration) and sulfate compounds (which generally accelerates the hydration of calcium
silicate cement phases while retarding the hydration of calcium aluminate phases) in each
CKD could produce this effect. Second, a dense membrane of initial hydration products
could be forming on the cement grains as a result of the large amounts of ions released
into solution by each CKD. CKDs commonly consist of water soluble compounds – such
as alkali chlorides, alkali sulfates, and lime – that result in highly alkaline solutions when
mixed with water (Dyer et al., 1999). The high pH levels produced by each CKD
dissolving into solution are also likely to promote the formation of hydration products
and lead to higher heat evolved values. Dyer et al. (1999) also arrested hydration of the
cement pastes at 2, 7, and 28 days. As discussed in the report, the hydration of pastes
with cement alone typically involves the reduction of sulfate ions to the point at which
further formation of AFt becomes impossible and AFm hydrates begin to form. Dyer et
al. (1999) concluded that the increased quantities of sulfate introduced as part of each
CKD inhibited the conversion of AFt to AFm phases. This led to increased AFt for these
blends. Further, there were two AFm phases identified in the CKD-PC blends at later
ages: calcium monosulphoaluminate hydrate (typical) and calcium monochloroaluminate
hydrate (Friedel’s salt which is atypical). Dyer et al. (1999) noted that Friedel’s salt only
forms when the free sulfate ions have already been largely consumed.
A summary of the limited number of studies conducted on the hydration effects of CKD-
PC blends compared to each reference plain cement is shown in Table 2.16. The effects
of CKD-PC blends were reported to be higher free lime (calcium oxide and calcium
hydroxide) in the paste, less C-S-H formation, higher heat evolution during initial
hydrolysis, delayed beginning and end of induction period, higher maximum heat value at
86
15% CKD replacement and lower maximum heat value at 25% CKD replacement,
delayed maximum heat value, higher AFt content, and the presence of Friedel’s salt at
less than 28 days. The suggested mechanisms of a CKD-PC blend upon hydration are:
higher alkali concentration in solution causing acceleration or retardation of silicate
dissolution depending upon the alkali/silicate ratio, higher chloride, and higher sulfate
contents.
Table 2.16 Hydration: from CKD-PC literature review Author(s)
Blend General Effect on Paste Hydration
Author Suggested Mechanism(s)
El-Aleem et al. (2005)
CKD 2/PC 4 (1) Higher free lime content. (2) Less C-S-H formation
(1) Higher CKD free lime content. (2) Lower chemically combined H2O (3) Higher evaporable H2O
Wang et al. (2002) CKD 5/PC 7 (3) Higher heat evolution during initial hydrolysis.
(4) Induction period began and ended later.
(5) Higher maximum heat value at 15% CKD replacement of PC, but lower maximum heat value at 25% CKD replacement level.
(4) High alkali dissolution during initial hydrolysis cause effects (4) and (5).
(5) Optimum alkali:silica ratio at 15% CKD replacement of PC.
(6) Excessive amounts of CKD depress dissolution and retard hydration of silicates at 25% CKD replacement of PC.
Dyer et al. (1999) CKD 7/PC 9 CKD 8/PC 9
(6) Higher maximum heat value. (7) Time of maximum heat value
was delayed. (8) Higher ettringite (AFt)
content. (9) Friedel’s salt present at <
28days.
(7) Combined effect of potassium chloride and sulfate compounds could cause effects (7) and (8).
(8) Rapid ion dissolution form a dense membrane of initial hydration productcs. Higher pH, however, is less likely to promote hydration products and higher heat values.
(9) High CKD sulfate content cause effect (8). (10) High chloride content cause effect (9).
87
2.5.5 Compressive Strength
Maslehuddin et al. (2008b) studied the compressive strength effect of replacing PC 1 (TI)
and PC 2 (TV) with CKD 1 at 0%, 5%, 10%, and 15% replacement by mass in concrete.
The compressive strength development after 3, 7, 14, 28, 56, and 90 days of curing were
tested, according to ASTM C39. The compressive strength development at the different
percentage levels of CKD 1 replacement of PC 1 and PC 2 is shown in Figure 2.19. For
PC 1, all of the concrete mixes with CKD 1 at 3 and 7 days had lower compressive
strength (>5%) than PC 1 alone. At all other ages, the compressive strength of 0% and
5% CKD concrete mixes with PC 1 was similar (±5%). The PC 1 concrete mixes
incorporating 10% and 15% CKD 1 had lower compressive strength (>5%) in
comparison to PC 1 alone at ages tested after 7 days. For PC 2, the compressive strength
of 0% and 5% CKD concrete mixes with PC 2 was similar (±5%) at all ages tested except
56 days (>10%). However, there was generally a decrease in compressive strength (>5%)
in the PC 2 concrete mixes with 10% and 15% CKD 1 at all ages, in comparison to PC 2
alone. The authors concluded that up to 5% CKD could be used without apprehension of
the reduction in compressive strength, despite the low compressive strength with PC 1 at
3 and 7 days and low compressive strength with PC 2 at 56 days.
88
(a)
(b)
Figure 2.19 Concrete compressive strength of CKD 1 at different replacement levels of
(a) PC 1 and (b) PC 2 (Maslehuddin et al., 2008b)
89
Maslehuddin et al. (2008a) studied the compressive strength effect of replacing PC 3 with
CKD 1 at 0%, 5%, and 10% replacement by mass in mortars. The mortar mixes had a w/b
ratio of 0.485 and were tested at 1, 3, 7, and 28 days. The compressive strength of all
CKD-PC blends was higher than PC alone at all ages, as shown in Table 2.17. At 1 day,
the blends with CKD at 5% and 10% replacement had 28% and 34% higher strength than
PC alone, respectively. At 3 days, the blends with CKD at 5% and 10% replacement had
44% and 51% higher strength than PC alone, respectively. At 7 days, the blends with
CKD at 5% and 10% replacement had 20% and 21% higher strength than PC alone,
respectively. Finally, at 28 days, the blends with CKD at 5% and 10% replacement had
5% and 11% higher strength than PC alone, respectively. At all ages, the compressive
strength increased as the quantity of CKD in the mortar mixes increased.
Table 2.17 Mortar compressive strength of CKD 1 at 0%, 5%, and 10% replacement of
PC 3 as a function of time (Maslehuddin et al., 2008a)
Average Compressive Strength (MPa)
1 day 3 day 7 day 28 day
100% PC 3 6.31 15.04 22.93 33.17
95% PC 3, 5% CKD 1 8.09 21.60 27.60 34.79
90% PC 3, 10% CKD 1 8.43 22.71 27.69 36.89
El-Aleem et al. (2005) studied the compressive strength effect of replacing PC 4 with
CKD 2 at 0%, 2%, 4%, 6%, 8%, and 10% replacement in mortars according to ASTM
C109. The w/b ratio was increased to maintain a constant flow. The mortar compressive
strength tests were conducted at 3, 7, 28, and 90 days, as shown in Figure 2.20. El-Aleem
et al. (2005) reported that the compressive strength for mortar cubes decreased slightly at
all ages with CKD content of up to 6%. Above this percentage, the compressive strength
decreased sharply. The reduction of compressive strength is suggested to be caused by:
90
(i) the reduction in the cement content, (ii) an increase in the w/b ratio as the percentage
of CKD in the blend increased, (iii) an increase in free lime content in cement dust; the
higher amount of Ca(OH)2 weakened the hardened matrix, (iv) the formation of chloro-
and sulfoaluminate phases leads to the softening and expansion of the hydration products,
and (v) the porosity also increases, due to the high chloride (7.5%) and sulfate (5.10%)
content of CKD 1 (Note: the formation of these products enhances the crystallization of
hydration products leading to an opening of the pore system). El-Aleem et al. (2005)
concluded that the substitution of PC with CKD up to 6% has no significant effect on the
compressive strength of hardened mortar.
Figure 2.20 Mortar compressive strength as a function of time at different percentage
levels of CKD 2 replacement of PC 4 (El-Aleem et al., 2005)
I.1 Control I.2 2% CKD I.3 4% CKD I.4 6% CKD I.5 8% CKD
I.6 10% CKD
91
Al-Harthy et al. (2003) investigated the compressive strength effect of using CKD 3 as a
partial replacement of PC 5 using mortars. The different mortar levels of CKD
replacement of PC by mass were 0%, 10%, 20%, 25%, and 30%. The w/b ratio of each
mortar mix varied to maintain constant flow. The mortar mixes were tested at 28 days
and showed the CKD blended strengths to be lower than the control (31 MPa). Al-Harthy
et al. (2003) attributed the lower strengths to the higher w/b ratios of the CKD blended
mortars. The 10% CKD blend had a compressive strength of 27 MPa and the 20% CKD
blend had a compressive strength of 23 MPa. It is interesting to note that the 25% CKD
blend (24 MPa) and 30% CKD blend (24 MPa) had comparable strengths to the 20%
CKD blend.
Al-Harthy et al. (2003) also used seven different concrete mixtures that were prepared
using 0 (control), 5, 10, 15, 20, 25, and 30% CKD 3 replacement by total mass of PC 5.
For each mixture, three water-binder ratios of 0.70, 0.60, and 0.50 by mass were used and
the ages tested were 3, 7, and 28 days, as shown in Figure 2.21. A major observation by
the authors was that there is generally a decrease in compressive strength with an increase
in CKD replacement for cement. The authors also observed that there is more decrease in
compressive strengths in mixes with higher w/b ratios (0.70) than in those mixes with
low w/b ratios (0.50). At 5% and 10% CKD 3 substitution for PC 5, the reductions in the
28 day compressive strength were 1.8% and 4.5%, respectively (w/b of 0.50). At higher
w/b ratio (0.60) the 28 day compressive strength reductions were more significant (12.4%
and 18% decreases in strength for 5% and 10% CKD 3 replacement of PC 5). Al-Harthy
et al. (2003) stated that CKD is not highly cementitious and the replacement of cement by
CKD will lead to less cement content and, therefore, less strength. However, small
amounts of 5% and 10% CKD substitution do not seem to have an appreciable adverse
effect on strength, especially at low w/b ratios.
92
(a)
(b)
(b)
(c)
Figure 2.21 Concrete compressive strengths, w/b (a) 0.70, (b) 0.60, and (c) 0.50, at
different percentage levels of CKD 3 replacement of PC 5 (Al-Harthy et al., 2003)
93
Udoeyo and Hyee (2002) studied the compressive strength effect of replacing PC 6 with
CKD 4 at 20%, 40%, 60%, 80%, and 100% replacement in concrete at a w/b ratio of
0.65. The tests were conducted at 1, 3, 7, and 28 days. Udoeyo and Hyee (2002) reported
that the strength decreased with an increase in CKD content at these very high
replacement levels. For example, the 28-day reduction in compressive strength compared
to the plain concrete was 7.5%, 33.2%, 71.8%, and 85.3%, respectively, for concrete with
20%, 40%, 60%, and 80% replacement levels of PC 6 with CKD 4. The strength results
suggest that CKD 4 is poorly hydraulic.
Wang et al. (2002) studied the effect of CKD 5 at partial replacement levels of PC 7 at
0%, 15%, and 25% on 28-day compressive strength with mortars at a w/b ratio of 0.50.
Wang et al. (2002) found that the compressive strength of blends with CKD and cement
increased with the CKD replacement of cement up to 15% (47.8 MPa) in comparison to
cement alone (46.3 MPa). The specimen with 25% CKD (39.4 MPa) had a much lower
compressive strength than the plain cement specimen. Wang et al. (2002) stated that it is
commonly accepted that the low hydraulic property of CKD causes the compressive
strength to decrease as the amount of CKD replacement increases. Wang et al. (2002)
also suggested that the increased strength in the specimen with 15% CKD may be
attributed to an appropriate alkalinity that increases the dissolution of silicate species and
formation of C-S-H. The authors also noted that 15% CKD replacement of PC
significantly reduces the volume fraction of pores larger than 3 µm, which may result in
improved strength.
Shoaib et al. (2000) conducted compression strength tests on concrete using CKD 6 as a
partial replacement of PC 8 at 0%, 10%, 20%, 30%, and 40% and a w/b ratio of 0.5. The
tests were conducted at one, three, and six months. The authors reported that the
compressive strength decreased with increasing amounts of CKD. Shoaib et al. (2000)
concluded that the critical value of CKD replacement of cement for compressive strength
requirements is 10%. They attributed the compressive strength loss to the reduction in
94
cement clinker, which is mainly responsible for strength development. They also
concluded that the higher concentration of chlorides present in CKD led to a reduction of
strength. It was reported that the chlorides caused the hydration products to crystallize,
which resulted in an increase in the total porosity of the hardened sample, thus reducing
the compressive strength. The authors further stated that the chloride ions take part in
chemical reactions (similar to those involving sulfate ions) and yield chloro-aluminate
hydrate 3CaO.Al2O3.CaCl2.12H2O, which can cause softening. Shoaib et al. (2000)
reported that due to the presence of alkalis, the microstructure of C-S-H phases became
heterogeneous and lowered the ultimate compressive strength.
Batis et al. (1996) used PC 10 and two CKDs (CKD 9 and CKD 10) for testing 90-day
compressive strength concrete containing CKD. Each CKD was added as a 6% partial
cement replacement, and the w/b ratio was varied at 0.65, and 0.75. At w/b ratio of 0.65
the level of 90-day compressive strength of the specimens with CKD was the same as the
plain cement specimen. At a w/b ratio of 0.75, however, the concrete specimen with CKD
9 had a 35% reduction in compressive compared to the CKD 10 concrete and plain
cement specimens. Batis et al. (1996) concluded that concrete made with CKD 10 at 6%
replacement of PC 10 exhibited as good performance as the reference concrete. In
addition, the authors noted that the incorporation of CKD 10 reduced the porosity of
concrete from approximately 14% (reference) to 10%, as measured with mercury
intrusion porosimetry (MIP) at w/b ratios of 0.65 and 0.75 and after 6 months of exposure
in NaCl. It is widely accepted that a reduction in porosity improves compressive strength.
El-Sayed et al. (1991) conducted 28-day compressive strength tests on cement pastes
consisting of PC 11 and CKD 11. The CKD was blended at 0%, 3%, 5%, 6%, 7%, and
10% replacement of cement. The w/b ratio of pastes was 0.30. El-Sayed et al. (1991)
reported that as the percentage of CKD content in the paste increased, the compressive
strength measurements decreased. The authors also reported that up to 5% CKD
95
replacement of PC was within the range of the Egyptian Standard Specifications for
Ordinary and Rapid Hardening Cement (36 MPa).
Wang and Ramakrishnan (1990) investigated the compressive strength properties of
mortar and concrete made with a binary blend consisting of 5% CKD (CKD 12) and 95%
TIII cement (PC 12). The mortar mixes had a w/b ratio of 0.485 and were tested at 1, 3, 7,
14, 28, and 90 days. The authors reported that there was no significant difference in the
compressive strengths of CKD-PC mortar and plain PC mortar specimens. Most of the
CKD-PC mortar strengths fell within plus or minus 1.4% of the strength of plain PC
mortar. The concrete mixes were tested at w/b ratios of 0.45, 0.52, and 0.55 at 1, 3, 7, and
28 days. The authors stated that most of the strengths for CKD-PC concrete were 4%
higher in the earlier tests and 3.5% lower at 28 days than for plain cement concrete.
Ramakrishnan (1986) also used CKD 12 to determine whether it was suitable as a 5%
replacement of TI cement (PC 15). Mortar and concrete testing was conducted to assess
compressive strengths. The mortar mixes had a w/b ratio of 0.485 and were tested at 1, 3,
7, 14, 28, and 90 days. Ramakrishan (1986) noted that although the difference in strength
between blended and plain cement mortar cubes was very small, the blends with CKD
nearly always had the lower strength in comparison to the plain cement. Ramakrishan
(1986), therefore, stated that the mortar specimens showed that the CKD did not possess
any cementitious property. The concrete mixes were tested at a cement content of 386
kg/m3 and w/b ratio of 0.45. Six sets of each concrete mix were batched. The concrete
mixes were tested at 1, 3, 7, 28, and 90 days. As opposed to the mortar specimens, the
concrete with CKD had equal or higher compressive strengths than the plain concrete at
all ages of testing, with the exception of the compressive strengths at 28 days.
Ramakrishan (1986) therefore concluded that there was no significant difference in the
compressive strength of blended and cement concretes. The author did not explore the
reasons for the different impact of CKD on compressive strength between mortars and
concrete.
96
Bhatty (1986) used a TI cement (PC 16) with three different CKDs (CKD 13, CKD 14,
and CKD 15) to investigate their effect on compressive strength in mortars. The amount
of CKD in each blend was fixed at 10% by mass of PC with a w/b ratio of 0.45.
Compressive strengths were determined at 1, 7, 28, and 90 days, and one year. Bhatty
(1986) reported that the blends of cement and CKD at 10% partial replacement had
higher strengths at one day, but were generally lower at 7, 28, and 90 days in comparison
to cement alone. The strengths of mortars with CKD after one year, however, were
comparable to cement alone.
Bhatty (1985a) used the same CKD (CKD 13, CKD 14, and CKD 15) and cement (PC
16) as Bhatty (1986) to conduct paste compressive strength testing. Cement and CKD
blends were prepared by replacing 10% and 20% of cement and a w/b ratio of 0.45.
Compressive strengths were determined at 1, 7, 28, and 90 days, and one year. Bhatty
(1985a) stated that all blends with CKD had similar or higher strengths compared to
cement at one day, with CKD 14 blends producing much higher strengths compared to
cement and cement blends with CKD 13 and CKD 15. Blends with CKD 15 generally
showed significantly lower strengths at later ages compared to CKD 13 and CKD 14.
Bhatty (1985a) also noted that a significantly higher strength at one day was obtained for
the blend with 10% CKD 15 compared to that with 20% CKD 15, while the other blends
were quite comparable. From seven days to one year, blends made with 10% CKD
replacement generally showed higher strengths compared to blends with 20% CKD
replacement. This study showed that the strengths are adversely affected when high alkali
chloride (potassium chloride) CKD was used. Bhatty (1985a) observed that the higher
amounts of calcium carbonate in dusts appeared to be detrimental to strength
development, but higher free lime appeared to be beneficial for strength. Blends with
CKD containing higher amounts of sulfate developed higher strength compared to blends
made with CKD containing lower amounts of sulfate. Also, when sulfate was present in
97
the form of calcium sulfate (CKD 14), better strengths were obtained than when some of
the sulfate was also present in the form of alkali sulfates (CKD 13).
Bhatty (1984) also conducted compressive strength testing on pastes using five
companion cements and dusts obtained from five different cement plants. The five
companion cement kiln dust blends are: PC 17 and CKD 13, PC 18 and CKD 14, PC 19
and CKD 15, PC 20 and CKD 16, and PC 21 and CKD 17. For each CKD blend, the
CKD replacement of the PC was 0%, 10%, 15%, and 20% at a w/b ratio of 0.50. Bhatty
(1984) stated that at all ages, as the amount of CKD increased, the strength generally
decreased except with CKD 15, which consistently showed higher strength at 20%
addition compared to 10% and 15% addition levels. CKD 15 contained a much higher
chloride and alkali content and much lower sulfate content than the other CKDs. Bhatty
(1984) stated that alkali chlorides would probably behave similarly to calcium chloride,
and calcium chloride is known to increase concrete strength, especially at one to three
days curing. The author also reported that the strengths for blends containing CKD 15
were higher at one and seven days than at 28 and 90 days, when compared to cement at
the same ages. Also, strengths increased steadily with the increase in chloride level for
blends with CKD 15. The CKD-PC blends not containing CKD 15 decreased in strength
as the amount of CKD increased. This trend was more prominent in blends with CKD 16
and CKD 17, which contained moderate amounts of alkali and sulfates in the form of
alkali and calcium sulfates than in the blends with CKD 14 where the sulfate was
predominantly calcium sulfate. Bhatty (1984) concluded that the compressive strengths
for CKD blends containing 10%, 15%, and 20% were lower than cement alone. The
highest loss in strength occurred when CKDs with relatively high alkali and chloride
contents were used. However, as the amount of this CKD increased in the blend, the
strength also increased, likely due to an accelerating effect of alkali chlorides on
hydration.
98
Ravindrarajah (1982) used concrete mixes to study the compressive strength effect of
CKD 18 as a partial cement replacement of PC 22 at 1, 3, 7, 14, 28, 56, and 90 days.
Cement was partially replaced with CKD by mass at 0%, 15%, 25%, 35%, and 45%. The
total water content for each mix was different to produce a similar workability.
Ravindrarajah (1982) reported that as the percent of cement replaced by CKD increased
the compressive strength decreased, and the magnitude of strength reduction was
increased with the increase in CKD. The author cited four possible mechanisms to
explain the impact of CKD replacement of PC on compressive strength in these tests: (i)
alkalis in the CKD may modify the nature and strength of the cement hydration products,
(ii) since the CKD dust particles are finer than cement, the hydration of the cementitious
particles in the dust may occur at a faster rate than the PC. The author noted this by the
development of strength with age expressed as a percentage of its 28 day strength for the
control and CKD blended mixes. In general, the concrete with no CKD replacement
showed the lowest percentage of the 28-day strength at early ages when compared with
the CKD concrete, (iii) the portion of CKD that is not cementitious may act as a fine filler
and contribute to an increase in strength through increased compaction or provision of
nucleation sites for cement hydration, and (iv) concrete compressive strength is a
function of paste strength, aggregate strength, and aggregate-paste bond strength. The
presence of CKD causes the paste to become weaker, and as the paste strength weakens,
the aggregate-cement paste bond also weakens. Ravindrarajah (1982) concluded that
from his limited research, cement in concrete could be safely replaced by up to 15% of
CKD by mass from the perspective of short-term strength requirements.
99
A summary of the effects of studies conducted on compressive strength (f’c) with CKD-
PC blends compared to each of the respective reference plain cements is shown in Table
2.18. Although there were variations between researchers, generally the compressive
strength of samples with CKD was lower than those of the control cement samples. Some
of the suggested mechanisms for the reduction in strength are a reduction in the cement
content, an increase in the w/b ratio (for mixes that varied water to maintain the same
workability of all mixes), formation of portlandite, formation of chloro- and sulfo-
aluminate phases, higher porosity, lack of CKD cementitious value (low hydraulic
property), weakening of the paste-aggregate bond, and poor formation of C-S-H due to
alkalis from CKD. Some researchers reported that there was less of a decrease in
compressive strength between plain cement and CKD blends at lower w/b ratios. Some
researchers also noted that the CKD blends were higher at early ages and lower at later
ages than for plain cement. An appropriate alkalinity that increases the dissolution of
silicate species and formation of C-S-H and CKD acting as fine filler were suggested as
mechanisms that could cause an increase in the compressive strength of cement with
CKD as a partial substitute.
100
Table 2.18 Compressive strength: from CKD-PC literature review
Author(s)
Blend Type w/b % CKD Replacement
General Effect on f’c
Author Suggested Mechanism(s)
Maslehuddin et al. (2008b)
CKD 1/PC 1 CKD 1/PC 2
C N.R. 0,5,10,15 5% N.C 10-15% ↓
Maslehuddin et al. (2008a)
CKD 1/PC 3 M 0.485 0,5,10 ↑
El-Aleem et al. (2005)
CKD 2/PC 4 M V 0,2,4,6,8,10
↓
(1) Reduction in the cement content
(2) An increase in the w/b ratio
(3) Increase in free lime content in cement dust; the higher amount of Ca(OH)2 weakened the hardened matrix.
(4) The formation of chloro-and sulfoaluminate phases leads to the softening and expansion of the hydration products.
(5) The porosity increases due to the high chloride (7.5%) and sulfate (5.10%) content of the CKD (formation of these products enhances the crystallization of hydration products leading to an opening of the pore system).
Al-Harthy et al. (2003)
CKD 3/PC 5 M C
V K
0,10,20,25,30 0,10,20,25,30
↓ ↓
(6) More decrease in compressive strength at higher w/b ratios
(7) CKD is not highly cementitious.
Udoeyo and Hyee (2002)
CKD 4/PC 6 C 0.65 0,20,40,60,80 ↓
P = Paste; M = Mortar; C = Concrete V = varied w/b ratio to maintain consistent workability K = constant w/b ratio, but more than one w/b ratio was tested N.C. = No Change f’c = compressive strength
101
Table 2.18 (continued) Compressive strength: from CKD-PC literature review
Author(s)
Blend Type w/b % CKD Replacement
General Effect on f’c
Author Suggested Mechanism(s)
Wang et al. (2002)
CKD 5 / PC 7 M 0.50 0,15,25 15% ↑ 25% ↓
(8) Low hydraulic property of CKD causes the compressive strength to decrease.
(9) Increased strength of 15% CKD-PC blend may be attributed to an appropriate alkalinity that increases the dissolution of silicate species and formation of C-S-H.
(10) At 15% CKD replacement of PC, the reduction of volume fraction of pores larger than 3um may result in improved strength.
Shoaib et al. (1999)
CKD 6 / PC 8 C 0.50 0,10,20,30,40 ↓ (11) Loss of cement clinker which is mainly responsible for strength development
(12) CKD Cl- cause crystallization of hydration products resulting in opening of pore system of the hardened samples leading to strength loss
(13) Chloro-aluminate formation causes softening
(14) CKD alkalis cause the C-S-H phases to become heterogeneous & lowers strength
Batis et. al (1996)
CKD 9 / PC 10 CKD 10/ PC 10
C C
K K
0,6 0,6
↓ N.C.
(15) CKD 9 concrete specimen was same as control at w/b of 0.65, but at 0.75 was dramatically lower.
(16) CKD 10 concrete specimen had lower porosity (MIP) compared to the concrete specimen without CKD.
El-Sayed et al. (1991)
CKD 11 / PC 11
P
0.30 0, 3,4,5,6,7,10
↓
Wang and Ramakrishnan (1990)
CKD 12/PC 12 M C
0.485 K
0,5 0,5
N.C. N.C.
(17) Most of the CKD concrete specimens were 4% higher at early ages and 3.5% lower at 28 days than for plain concrete specimens.
Ramakrishnan (1986)
CKD 12/PC 15 M C
0.485 0.45
0,5 0,5
↓ N.C.
(18) CKD does not possess any cementitious value.
Bhatty (1986)
CKD 13/PC 16 CKD 14/PC 16 CKD 15/PC 16
M M M
0.45 0.45 0.45
0,10 0,10 0,10
1d ↑, rest ↓ 1d ↑, rest ↓ 1d ↑, rest ↓
P = Paste; M = Mortar; C = Concrete V = varied w/b ratio to maintain consistent workability K = constant w/b ratio, but more than one w/b ratio was tested N.C. = No Change f’c = compressive strength
102
Table 2.18 (continued) Compressive strength: from CKD-PC literature review
Author(s)
Blend Type w/b % CKD Replacement
General Effect on f’c
Author Suggested Mechanism(s)
Bhatty (1985a)
CKD 13/PC 16 CKD 14/PC 16 CKD 15/PC 16
P P P
0.45 0.45 0.45
0,10,20 0,10,20 0,10,20
1d ↑, rest ↑↓ 1d ↑, rest ↑↓ 1d ↑, rest ↑↓
(19) High alkali chloride (KCl) in CKD reduces f’c.
(20) High calcium carbonate in CKD reduces f’c.
(21) Higher free lime in CKD increases f’c.
(22) Blends with CKD containing higher amounts of sulfate developed higher strength compared to blends made with CKD containing lower amounts of sulfate.
(23) When sulfate was present in the form of calcium sulfate (CKD 14), better strengths were obtained than when some of the sulfate was also present in the form of alkali sulfates (CKD 13).
Bhatty (1984)
CKD 13/PC 17 CKD 14/PC 18 CKD 15/PC 19 CKD 16/PC 20 CKD 17/PC 21
P P P P P
0.50 0.50 0.50 0.50 0.50
0,10,15,20 0,10,15,20 0,10,15,20 0,10,15,20 0,10,15,20
1d N.C., rest ↓
1d ↑, rest ↓ ↓
1d N.C., rest ↓ ↓
(24) Strengths increased steadily with increase in chloride level for blends with CKD 15.
(25) The CKD-PC blends not containing CKD 15 decreased in strength as the amount of CKD increased. This trend was more prominent in blends with CKD 16 and CKD 17 which contained moderate amounts of alkali and sulfates in the form of alkali and calcium sulfates than in the blends with CKD 14 where the sulfate was predominantly calcium sulfate.
(26) The highest loss in strength occurred when CKD with relatively high alkali and chloride contents were used. However, as the amount of this CKD increased in the blend, the strength also increased, likely due to an accelerating effect of alkali chlorides on hydration (acting similar to calcium chloride).
Ravindrarajah (1982)
CKD 18/PC 22 C V
0,15,25,35,45
↓
(27) Alkalis may modify hydration products.
(28) CKD may act as a fine filler. (29) CKD presence weakens
paste and aggregate-paste bond.
P = Paste; M = Mortar; C = Concrete V = varied w/b ratio to maintain consistent workability K = constant w/b ratio, but more than one w/b ratio was tested N.C. = No Change f’c = compressive strength
103
2.5.6 Flexural and Tensile Strength
Al-Harthy et al. (2003) investigated the flexural strength effect of using CKD 3 as a
partial replacement of PC 5 using concrete. Al-Harthy et al. (2003) used seven different
concrete mixtures that were prepared using 0 (control), 5%, 10%, 15%, 20%, 25%, and
30% CKD 3 replacement by total mass of cement. For each mixture, three water-binder
ratios of 0.50, 0.60, and 0.70 by mass were used (the age at which the specimens were
tested was not specified but it is assumed that it was at 28 days). Flexural strength
measurements were determined using a two-point loading system. Toughness values,
which measure the ability of a material to absorb energy up to fracture, were calculated
based on the area under the stress-strain diagram. Similar to the effects on compressive
strength, the authors stated that the flexural strength and toughness values decreased with
an increase in CKD replacement for cement but at 5% and 10% replacement levels did
not have an appreciable adverse effect (especially at low w/b ratios). Al-Harthy et al.
(2003) attributed the reduction in flexural strength and toughness values to a reduction in
the cement content in the blends as the amount of CKD increased.
Udoeyo and Hyee (2002) studied the split tensile strength and modulus of rupture effects
of replacing PC 6 with CKD 4 at 20%, 40%, 60%, 80%, and 100% replacement in
concrete at a w/b ratio of 0.65. The tests were conducted at 1, 3, 7, and 28 days. Similar
to the results of compressive strength, Udoeyo and Hyee (2002) reported that the split
tensile strength and modulus of rupture decreased with an increase in CKD content. The
reduction in split tensile strength compared to the plain concrete was approximately 24%,
48%, 65%, and 90%, respectively, for concrete with the very high 20%, 40%, 60%, and
80% replacement levels of PC 6 with CKD 4. The reduction in modulus of rupture
compared to the plain concrete was approximately 18%, 70%, and 90%, respectively, for
concrete with 20%, 40%, and 60% replacement levels of PC 6 with CKD 4. Udoyeo and
Hyee (2002) did not suggest possible mechanisms for CKD-PC effects on split tensile
strength and modulus of rupture.
104
Wang et al. (2002) studied the effect of CKD 5 at partial replacement levels of PC 7 at
0%, 15%, and 25% on 28-day flexural strength with mortars at a w/b ratio of 0.50. Wang
et al. (2002) found that the flexural strength of blends with CKD and cement increase
with the CKD replacement of cement up to 15% (8.5 MPa) in comparison to cement
alone (8.2 MPa). The specimen with 25% CKD (7.6 MPa) had a much lower flexural
strength than the plain cement specimen. Wang et al. (2002) stated that the increased
strength in the specimen with 15% CKD may be attributed to an appropriate alkalinity
that increased the dissolution of silicate species and formation of C-S-H. Wang et al.
(2002) also reported that 15% CKD replacement of PC significantly reduced the volume
fraction of pores larger than 3 µm, which may result in improved strength.
Shoaib et al. (2000) conducted splitting tensile strength tests on concrete using CKD 6 as
a partial replacement of PC 8 at 0%, 10%, 20%, 30%, and 40% at a w/b ratio of 0.5. The
tests were conducted at one, three, and six months. The authors reported a gradual
decrease in the splitting tensile strength for all cylinders of concrete samples as the
amount of CKD increased. The reduction in tensile strength was attributed to the lower
bond strength between the aggregate and paste. Shoaib et al. (2000) stated that as the
amount of CKD increased in the paste, the bond strength between the aggregate and the
paste decreased.
Wang and Ramakrishnan (1990) studied the splitting tensile and flexural strength
properties of binary blends consisting of 5% CKD (CKD 12) and 95% Type III cement
(PC 12). The splitting tensile strength mortar mixes had a w/b ratio of 0.485 and were
tested at 1, 3, 7, 14, 28, and 90 days. The 14-day tensile strength of the CKD mortar was
10% higher than for the plain cement mortar. At 28 and 90 days, however, there was no
significant difference in the tensile strengths of the plain cement and CKD-PC specimens.
The flexural strength concrete mixes were tested at w/b ratios of 0.45, 0.52, and 0.55 at 1,
3, 7, and 28 days. Wang and Ramakrishnan (1990) stated that the results of flexure
strength tests of concrete specimens with CKD were within a range of ±4% of those of
105
the plain cement concrete and, therefore, not significant. Wang and Ramakrishnan (1990)
did not suggest possible mechanisms for CKD-PC effects on split tensile and flexural
strength.
Ramakrishnan (1986) studied the mortar splitting tensile and concrete flexural strength
properties made with a binary blend consisting of 5% CKD (CKD 12) and 95% TI
cement (PC 15). The splitting tensile strength mortar mixes had a w/b ratio of 0.485 and
were tested at 1, 3, 7, 14, 28, and 90 days. Ramakrishnan (1986) reported that for most of
the CKD-PC mortar splitting tensile strengths were lower than the corresponding plain
cement mortar strengths. The flexural strength concrete mixes were tested at a w/b ratio
of 0.45 at 1, 3, 7, and 28 days. Ramakrishnan (1986) reported no significant difference in
flexural strength between concretes containing CKD and plain concrete.
Ravindrarajah (1982) used concrete mixes to study the flexural and tensile strength
effects of CKD 18 as a partial cement replacement of PC 22 at 1, 3, 7, 14, 28, 56, and 90
days. Cement was partially replaced with CKD by mass at 0%, 15%, 25%, 35%, and
45%. The total water content for each mix was varied to produce similar workability.
Ravindrarajah (1982) also conducted tests to determine the flexural and tensile strengths.
As in the compressive strength test results, the flexural and tensile strengths decreased
with increased replacement of cement with CKD.
A summary of the studies conducted on the flexural and splitting tensile effects of CKD-
PC blends compared to the referenced plain cement is shown in Table 2.19. Generally,
the flexural and tensile strength effects of samples with CKD were lower than those of
the control cement samples, which is similar to the compressive strength effects. Many of
the suggested mechanisms for the reduction in flexural and split tensile strengths were the
same as the mechanisms for the reduction in compressive strength. The most commonly
suggested mechanism was the weakening of the aggregate-paste bond due to the presence
of CKD.
106
Table 2.19 Flexural and tensile strength: from CKD-PC literature review
Author(s)
Blend Type
w/b % CKD Replacement
General Effect on f’t
Author Suggested Mechanism(s)
Al-Harthy et al. (2003)
CKD 3/PC 5 C K 0,10,20,25,30
↓
(1) Reduction in the cement content.
(2) Less effect at low w/b ratios.
Udoeyo and Hyee (2002)
CKD 4/PC 6 C 0.65 0,20,40,60,80 ↓
Wang et al. (2002)
CKD 5/PC 7 M 0.50 0,15,25 15% ↑ 25% ↓
(3) Increased strength 15% CKD specimen may be attributed to an appropriate alkalinity that increased the dissolution of silicate species and formation of C-S-H.
(4) At 15% CKD replacement of PC, the reduction of volume fraction of pores larger than 3um may result in improved strength.
Shoaib et al. (1999)
CKD 6/ PC 8 C 0.50 0,10,20,30,40 ↓ (5) Weaker aggregate-paste bond as CKD content increases.
Wang and Ramakrishnan (1990)
CKD 12/PC 12 M C
0.485 K
0,5 0,5
↑ N.C.
Ramakrishnan (1986)
CKD 12/PC 15 M C
0.485 0.45
0,5 0,5
↓ N.C.
Ravindrarajah (1982)
CKD 18/PC 22 C V 0,15,25,35,45
↓
(6) Alkalis may modify hydration products.
(7) CKD may act as a fine filler. (8) CKD presence weakened paste
and aggregate-paste bond.
P = Paste; M = Mortar; C = Concrete. V = varied w/b ratio to maintain consistent workability f’t = flexural and/or tensile strength K = constant w/b ratio, but more than one w/b ratio was tested. N.C. = No Change
2.5.7 Volume Stability
2.5.7.1 Soundness
Maslehuddin et al. (2008a) studied the soundness effect of replacing PC 3 with CKD 1 at
0%, 5%, and 10% replacement by mass in pastes using autoclave expansion (ASTM
C151). The PC alone, PC with 5% CKD replacement, and PC with 10% CKD
replacement were 0.0075%, 0.0130%, and 0.3730%, respectively. Although the CKD-PC
blends had higher expansions than PC alone and increased as the percentage of CKD
replacement increased, the autoclave expansions were below the 0.80% allowed by
ASTM C150.
107
Bhatty (1986) used a Type I cement (PC 16) with three different CKD (CKD 13, CKD
14, and CKD 15) to investigate the effect on autoclave expansion (ASTM C151). The
amount of CKD in each paste was fixed at 10% by mass of PC, with a w/b ratio of 0.45.
Bhatty (1986) stated that the type of CKD used in the binary blend influenced the
autoclave expansion. Bhatty (1986) reported that the CKD-PC blend with CKD 14
showed autoclave expansion comparable to cement alone but higher expansions were
noted for CKD 13 and CKD 15. Bhatty (1986) also noted that each CKD-PC blend
autoclave expansion was well below the ASTM C150 specification of 0.80%. Bhatty
(1986) generally noted that when binary, ternary, and quaternary blends were made from
PC 16, the three different CKD, fly ash and slag – the blends containing CKD 15 (a high
chloride dust) generally produced higher autoclave expansions than blends with CKD 14,
which contained high sulfate.
Ravindrarajah (1982) used cement pastes to determine the soundness of PC-CKD blends
using the Le Chatelier apparatus (EN 196-3). PC 22 was partially replaced with CKD 18
by mass at 0%, 25%, 50%, 75%, and 100%. The total water content for each mix was
varied to produce similar workability. As the CKD percentage increased, so did the
expansion of the samples. This was attributed to the higher level of free lime in the CKD
in comparison to cement. Although the level of expansion was well within the range of
the British Standard, the expansion was much higher than that of cement.
A summary of the studies conducted on the soundness of CKD-PC blends compared to
each of the respective reference plain cements is shown in Table 2.20. High free lime,
sulfate, and chloride contents in the CKDs were attributed to the increased autoclave
expansions.
108
Table 2.20 Soundness: from CKD-PC literature review Author(s)
Blend Type w/b % CKD Replacement
General Effect on Soundness
Author Suggested Mechanism(s)
Maslehuddin et al. (2008a)
CKD 1/PC3 P V 0,5,10 ↓
Bhatty (1986)
CKD 13/PC 16 CKD 14/PC 16 CKD 15/PC 16
P P P
0.45 0.45 0.45
0,10 0,10 0,10
↓ ↓ ↓
(1) High chloride CKD generally produced higher autoclave expansions than high sulfate CKD (includes mixes with slag, and fly ash).
Ravindrarajah (1982)
CKD 18/PC 22 C V
0,15,25,35,45
↓
(2) High CKD free lime content.
P = Paste; M = Mortar; C = Concrete. V = varied w/b ratio to maintain consistent workability N.C. = No Change
2.5.7.2 Drying Shrinkage
Maslehuddin et al. (2008b) studied the drying shrinkage effect of replacing PC 1 (TI) and
PC 2 (TV) with CKD 1 at 0%, 5%, 10%, and 15% replacement by mass in concrete. The
drying shrinkage strain after 3, 7, 14, 28, 56, and 90 days of curing were tested, according
to ASTM C157. The drying shrinkage strain at the different percentage levels of CKD 1
replacement of PC 1 is shown in Figure 2.22. For PC 1, the highest shrinkage strain at all
ages was with the 15% CKD 1 concrete specimens followed by the concrete specimens
with 10% and 5% CKD 1, respectively. The 5% CKD 1 concrete specimens with PC 1,
however, were only marginally higher (<5%) than the concrete specimens without CKD
1. Although the test results were not provided for PC 2 concrete specimens, it was
reported that the initial shrinkage strain in the concrete specimens with CKD 1 was more
than that in the concrete specimens without CKD 1. After 90 days, however, the
shrinkage strain of 0%, 5%, and 10% concrete specimens with PC 2 was more or less
similar while that of 15% CKD 1 concrete specimens with PC 2 was significantly higher
than that of the other concrete specimens with PC 2.
109
Figure 2.22 Concrete drying shrinkage as a function of time at different replacement
levels of PC 1 with CKD 1 (Maslehuddin et al., 2008b)
Maslehuddin et al. (2008a) studied the drying shrinkage effect of replacing PC 3 with
CKD 1 at 0%, 5%, and 10% replacement by mass in mortars, according to ASTM C157.
The w/b ratio for each mortar mix was adjusted to maintain a constant flow. The w/b
ratios, however, were not reported. Drying shrinkage tests were conducted at 7, 14, 21,
28, 45, 60, and 75 days, as shown in Table 2.21. The drying shrinkage of mortar mixes
with 5% CKD ranged between 19% and 43% higher drying shrinkage than that of the
mortar mix with PC alone for the ages tested. The drying shrinkage of mortar mixes with
10% CKD ranged between 38% and 68% higher drying shrinkage than that of the mortar
mix with PC alone for the ages tested.
110
Table 2.21 Mortar drying shrinkage with 0%, 5%, and 10% CKD 1 replacement of PC 3
(Maslehuddin et al., 2008a)
Average drying shrinkage (%)
7 days 14 days 21 days 28 days 45 days 60 days 75 days
100% PC 3 0.0380 0.0528 0.0620 0.0694 0.0739 0.0811 0.0847
95% PC 3, 5% CKD 1 0.0481 0.0742 0.0886 0.0918 0.0942 0.0977 0.1008
90% PC 3, 10% CKD 1 0.0532 0.0889 0.0924 0.1043 0.1098 0.1144 0.1173
Wang and Ramakrishnan (1990) compared the drying shrinkage properties of concrete
made with a binary blend consisting of 5% CKD (CKD 12) and 95% TIII cement (PC
12). The concrete mixes were tested at w/b ratios of 0.45 and 0.52 and the drying
shrinkage results are shown in Figure 2.23. The authors reported no significant difference
in drying shrinkage between the concrete mixes at w/b of 0.45. At 0.52 w/b ratio,
however, the concrete mix with CKD had considerably higher (22%) drying shrinkage
than the plain cement concrete. Wang and Ramakrishnan (1990) stated they did not know
the reason for this difference.
111
Figure 2.23 Concrete drying shrinkage as a function of time at two different w/b ratios
with 5% CKD 12 replacement of PC 12 (Wang and Ramakrishnan, 1990)
Ramakrishnan (1986) also used CKD 12 to determine whether it was suitable as a 5%
replacement of TI cement (PC 15). Concrete testing was conducted to assess drying
shrinkage at a w/b ratio of 0.45. Ramakrishnan (1986) reported that the shrinkage
deformation for CKD concrete mixes was a little more than that of the plain cement
concrete.
Bhatty (1986) used a Type I cement (PC 16) with three different CKDs (CKD 13, CKD
14, and CKD 15) to investigate their effect on drying shrinkage in mortars. The amount
of CKD in each blend was fixed at 10% by mass with a w/b ratio of 0.45. Drying
shrinkage tests were conducted at 4, 11, 18, and 25 days. For all blends containing CKD
13 and CKD 15 the drying shrinkage increased compared to cement alone. The blends
containing the high sulfate CKD 14, however, showed lower shrinkage than cement
alone. Bhatty (1986) concluded that the drying shrinkage of binary blends with high
sulfate CKD was lower than cement alone or other binary blends with low sulfate CKD.
Mix 2: w/b = 0.52
Mix 3: w/b = 0.45
112
A summary of the studies conducted on the drying shrinkage effects of CKD-PC blends
compared to each of the respective reference plain cements is shown in Table 2.22. It
appears that adverse effects on drying shrinkage of CKD-PC blends may be more
significant at higher w/b ratios. Bhatty (1986) stated that drying shrinkage of CKD-PC
blends with high sulfate content was lower than the control and other lower sulfate CKD-
PC blends. This was not expected since higher sulfate levels are typically associated with
drying shrinkage expansion. One possible explanation is that the high sulfate CKD may
have contained less soluble sulfate forms than the PC it replaced and the other CKDs.
Table 2.22 Drying shrinkage: from CKD-PC literature review
Author(s)
Blend Type w/b % CKD Replacement
General Effect on Drying Shrinkage
Author Suggested Mechanism(s)
Maslehuddin et al. (2008b)
CKD 1/PC 1 CKD 1/PC 2
C N.R. 0,5,10, 15 5% N.C. 10-15% ↑
Maslehuddin et al. (2008a)
CKD 1/PC 3 M V 0,5,10 ↑
Wang and Ramakrishnan (1990)
CKD 12/PC 12 C C
0.45 0.52
0,5 0,5
N.C. ↑
(1) Higher drying shrinkage at higher w/b ratio.
Ramakrishnan (1986)
CKD 12/PC 15 C 0.45 0,5
↑
Bhatty (1986)
CKD 13/PC 16 CKD 14/PC 16 CKD 15/PC 16
M M M
0.45 0.45 0.45
0,10 0,10 0,10
↑ ↓ ↑
(2) Drying shrinkage of binary blends with high sulfate CKD was lower than cement alone and other binary blends with low sulfate CKD
P = Paste; M = Mortar; C = Concrete. N.C. = No Change V = Varied w/b ratio to maintain consistent workability
2.5.7.3 Volume Stability Summary
The volume stability of CKD blends in the literature review was assessed by considering
the results of soundness and drying shrinkage. Three researchers reported that as the
CKD increased, the autoclave expansion also increased for all five of the CKD-PC
blends. One mechanism for this effect was suggested to be related to the high free lime
content of CKD. It was also reported that high chloride CKD generally produced higher
autoclave expansions than high sulfate CKD. Five researchers reported on drying
113
shrinkage. At 5 % CKD replacement, two CKD-PC blends had no change in drying
shrinkage while four other CKD-PC blends had higher drying shrinkage values compared
to the control cements. At 10% CKD replacement, five of the six CKD-PC blends had
increased drying shrinkage compared to the control cements. The CKD-PC blend that
decreased drying shrinkage was a high sulfate CKD, but it is likely that this CKD
contained less soluble forms of sulfate than the PC or the other CKDs. At 15 % CKD
replacement, the drying shrinkage values of the two CKD-PC blends were higher than
that at 10% CKD replacement. It was noted that higher drying shrinkage occurred at
higher w/b ratio.
2.5.8 Durability
2.5.8.1 Alkali-Aggregate Reaction
Bhatty (1986) used a Type I cement (PC 16) with three different CKDs (CKD 13, CKD
14, and CKD 15) in mortars to investigate their effect on alkali-aggregate reactivity
(AAR) according to ASTM C227. The aggregate used consisted of 95% Ottawa sand
(non-reactive aggregate) and 5% Beltane Opal (reactive aggregate). Opal contains
reactive silica that is used to assess the contribution of hydroxyl ions from the binder to
form ASR. In this test method, the mortar specimen bars are stored vertically in a sealed
environment above water, which is at the bottom of the container. The amount of CKD in
each blend was fixed at 10% by mass of PC with a w/b ratio of 0.45. The expansion
measurements were taken at 3 and 6 months. PC 16 contains a total alkali content of
0.53% as sodium oxide equivalent and is considered a low alkali cement according to
ASTM C150. The blends with CKD 13, CKD 14, and CKD 15, had total alkali contents
of 0.67%, 0.66%, and 0.82%, respectively. The expansions of CKD-PC blends at three
and six months were very similar to cement alone and significantly below the ASTM
limit of 0.1% at six months.
Bhatty (1985b) also conducted mortar bar expansion tests using four companion cements
and dusts obtained from four different cement plants to assess potential alkali-aggregate
114
reactivity using ASTM C227. The w/b ratio was 0.50 and measurements were taken
periodically over a one-year period. The four companion cement kiln dust blends are: PC
17 and CKD 13, PC 18 and CKD 14, PC 19 and CKD 15, and PC 20 and CKD 16. Each
CKD replacement of PC was at 0%, 10%, 15%, and 20%. Although the PCs and CKDs
from individual plants showed significant differences, all CKD blends exhibited higher
ASR induced expansions compared to the control PC alone. As the amount of CKD in the
blends increased, expansion also increased. Bhatty (1985b) stated that at six months the
highest expansion obtained was with CKD 16 blends while the lowest expansion was
obtained using CKD 13. Blends with CKD 15 produced lower expansions despite having
the same alkali contents as blends containing CKD 16. This is likely due to the fact that a
major portion of the alkali in CKD 15 is present as a chloride salt. CKD 14 blends had
similar water soluble alkali content to blends made with CKD 13 but showed much
higher expansion compared to the latter. Differences in expansion of blends containing
similar alkali contents can be attributed to the difference in chemical composition of
cements and dusts and to the type of alkali compounds present in these materials. Water
soluble alkali showed a more meaningful relationship with expansion than did total alkali
with respect to the 0.60% alkali limit for CKD-PC blends. The author concluded that kiln
dust is not the only material in a binary blend that can influence alkali-aggregate
expansion. Different cements with the same kiln dust can produce different expansion not
only due to differences in alkali content but also in other compositional variations.
A summary of the studies conducted on the alkali-aggregate reactivity of CKD-PC blends
compared to each of the respective reference plain cements is shown in Table 2.23.
115
Table 2.23 Alkali-aggregate reactivity: from CKD-PC literature review Author(s)
Blend Type w/b % CKD Replacement
General Effect on AAR
Author Suggested Mechanism(s)
Bhatty (1986)
CKD 13/PC 16 CKD 14/PC 16 CKD 15/PC 16
M M M
0.45 0.45 0.45
0,10 0,10 0,10
N.C. N.C. N.C.
Bhatty (1985b)
CKD 13/PC 17 CKD 14/PC 18 CKD 15/PC 19 CKD 16/PC 20
M M M M
0.50 0.50 0.50 0.50
0,10,15,20 0,10,15,20 0,10,15,20 0,10,15,20
↑ ↑ ↑ ↑
(1) As the amount of CKD in the blends increased, expansion also increased.
(2) Water soluble alkali showed a more meaningful relationship with expansion than did total alkali with respect to 0.60% alkali limit for CKD-PC blends.
(3) Blends with CKD 15 produced lower expansion despite having the same alkali contents as blends containing CKD 16. This is likely due to the fact that a major portion of the alkali in CKD 15 is present as a chloride salt.
(4) CKD 14 blends had similar water soluble alkali content to blends made with CKD 13 but showed much higher expansion compared to the latter.
(5) Differences in expansion of blends containing similar alkali contents can be attributed to the difference in chemical composition of cements and dusts and to the type of alkali compounds present in these materials.
(6) CKD is not the only material in a binary blend that can influence alkali-aggregate expansion. Different cements with the same kiln dust can produce different expansion not only due to differences in alkali content but other compositional variations as well
P = Paste; M = Mortar; C = Concrete N.C. = No Change.
116
2.5.8.2 Steel Corrosion
Maslehuddin et al. (2008b) studied the electrical resistivity effect of replacing PC 1 (Type
I) and PC 2 (Type V) with CKD 1 at 0%, 5%, 10%, and 15% replacement by mass in
concrete. Since electrical resistivity is a function of moisture content in the concrete,
resistance measurements were conducted at varying water content in the specimens. The
specimen was initially saturated in water for 28 days and afterward the electrical
resistivity was measured. The specimen was then allowed to dry and the electrical
resistivity measurements were taken periodically. Ultimately, the specimen was oven-
dried at 110°C and the moisture content determined. The electrical resistivity after 28
days (water curing) at the different percentage levels of CKD 1 replacement of PC 1 and
PC 2 was plotted against the moisture content, as shown in Figure 2.24. The electrical
resistivity decreased with increasing moisture content. The authors reported that the
electrical resistivity of PC 1 concrete mixes with CKD 1 at 0%, 5%, and 10% was not
significantly different. However, there was a significant decrease in electrical resistivity
of PC 1 concrete mixes with CKD 1 at 15%. For PC 2, the electrical resistivity decreased
significantly for all concrete specimens with CKD, in comparison to the concrete
specimens without CKD. The authors suggested that the decrease in electrical resistivity
due to the partial substitution of CKD 1 for PC2 in the concrete specimens may be
attributed to an increase in free chloride ions. The higher presence of free chloride ions in
PC2 concrete specimens with CKD in comparison to PC 1 concrete specimens with CKD
is possibly due to PC 2 having low-chloride binding properties (lower C3A content)
compared to PC 1. The authors used an electrical resistivity classification system to
assess the risk of reinforcement corrosion, as shown in Table 2.24. At a moisture content
of approximately 3%, the electrical resistivity of PC 1 and PC 2 concrete specimens with
and without CKD was in the range of approximately 25 – 50 kΩ.cm. Therefore,
according to Table 2.24, at approximately 3% moisture content the risk of steel
reinforcement corrosion for all of the concrete specimens is of moderate intensity.
117
(a)
(b)
Figure 2.24 Concrete specimen variation of electrical resistivity with moisture content at
different percentage levels of CKD 1 replacement of (a) PC 1 and (b) PC 2 (Maslehuddin
et al., 2008b)
118
Table 2.24 Concrete resistivity and risk of reinforcement corrosion as specified in COST
509 (Maslehuddin et al., 2008b)
Concrete resistivity (kΩ cm) Risk of reinforcement corrosion
<10 High
10-50 Moderate
50-100 Low
>100 Negligible
Konsta-Gdoutos et al. (2001) completed corrosion tests on mortar specimens using CKD
5 as a partial replacement of PC 7 at 0%, 15%, and 25% by mass. The mortar w/b ratio
was 0.50 and was mixed in accordance with EN 196-1. Mortar specimens of 75 x 75 x
300 mm were prepared and reinforced centrally with a 12M steel bar and a 12.7 mm
cover. They were cured for seven days in a curing room. To accelerate corrosion of the
embedded steel the specimens were immersed half way in a 5% (by mass) NaCl solution.
The results were interpreted according to ASTM C876 criteria for corrosion of steel in
concrete. The corrosion potential of the binary blends was monitored three times per
week. The half cell potential technique was used to measure the risk of corrosion. The
corrosion potentials observed for the CKD-PC blends suggest that more than 15% CKD
replacement of PC accelerates corrosion. This is possibly due to the introduction of
chloride ions in the mix incorporated in the CKD.
Batis et al. (1996) used PC 7 and 2 CKDs (CKD 8 and CKD 9) for testing steel corrosion
of concrete containing CKD. Each CKD was added as a 6% partial cement replacement
at three w/b ratios: 0.50, 0.65, and 0.75. Each concrete test specimen was reinforced with
steel bars and immersed in 3.5% by mass NaCl solution 5 cm from their bottom. The free
upper section of rebars were connected to copper cable and covered with epoxy resin.
The corrosion potential was measured every seven days. Batis et al. (1996) reported that
119
the blends with CKD 9 had improved corrosion resistance in comparison to the reference
mix. The blends with CKD 8 had reduced corrosion resistance in comparison to the
reference mix. The protective behavior of CKD 9 against corrosion is attributed to its
fineness and relatively higher alkalinity. Batis et al. (1996) also noted that CKD 8 had
double the chloride content and three times higher sulfate content compared to CKD 9.
The elevated chloride and sulfate ion contents accelerated the corrosion rate in the
concrete specimens made with CKD 8 at all w/b ratios.
El-Sayed et al. (1991) conducted steel corrosion tests on cement pastes and mortars
consisting of PC 11 and CKD 11. The tests were used to determine the potential level of
CKD replacement in pastes and mortars without impairing the passivity of the embedded
steel. The CKD was blended at 0%, 3%, 5%, 6%, 7%, and 10% replacement of cement.
The w/b ratio was 0.30 for pastes and 0.60 for mortars. For both pastes and mortars, as
the amount of CKD increased the passivity of steel decreased. El-Sayed et al. (1991)
determined that the steel passivity was maintained at an acceptable level up to 5% CKD
by mass of cement. The authors attributed the 5% CKD level of corrosion protection
from aggressive sulfate and chloride ions in the mix to the high hydroxide (OH-) content
that develops during hydration as a result of the CKD. El Sayed et al. (1991) concluded
that the OH- helped in maintaining the passive oxide layer that protected the steel.
A summary of the studies conducted on the steel corrosion of CKD-PC blends compared
to each of the respective reference plain cement is shown in Table 2.25.
120
Table 2.25 Steel corrosion: from CKD-PC literature review Author(s)
Blend Type w/b % CKD Replacement
General Effect on Steel
Corrosion
Author Suggested Mechanism(s)
Maslehuddin et al. (2008b)
CKD 1/PC 1 CKD 1/PC 2
C N.R. 0,5,10,15 ↑ (1) Decrease in electrical resistivity (higher risk of steel reinforcement corrosion) may be due to presence of free chloride ions from CKD
Konst-Gdoutos et al. (2001)
CKD 5/PC 7 M 0.50 0,15,25 ↑ (2) More than 15% CKD replacement of PC accelerated corrosion possibly due to the introduction of CKD chloride ions.
Batis et. al (1996)
CKD 9 / PC 10 CKD 10/ PC 10
C C
K K
0,6 0,6
↑ ↓
(3) Protective behavior of CKD 10 against corrosion was partially attributed to its higher fineness.
(4) Protective behavior of CKD 10 was partially attributed to its relatively higher alkalinity.
(5) CKD 9 had elevated chloride and sulfate ion contents (compared to CKD 10) – accelerated the corrosion rate.
El-Sayed et al. (1991)
CKD 11/ PC 11
P M
0.30 0.60
0,3,4,5,6,7,10 0,3,4,5,6,7,10
↑ ↑
(6) Corrosion protection from aggressive sulfate and chloride ions in the mix was attributed to the high hydroxide (OH-) content that developed during hydration as a result of the CKD. The OH- helped in maintaining the passivation film that protected the steel.
P = Paste; M = Mortar; C = Concrete. K = constant w/b ratio, but more than one w/b ratio was tesed. N.R. = Not Reported
121
2.5.8.3 Permeability
Maslehuddin et al. (2008b) studied the chloride permeability effect of replacing PC 1
(Type I) and PC 2 (Type V) with CKD 1 at 0%, 5%, 10%, and 15% replacement by mass
in concrete, as shown in Table 2.26. The chloride permeability was measured after 28
days of curing, according to ASTM C1202. The measure of chloride permeability (values
in Coulombs) increased with an increase in the CKD replacement of PC. At 5% CKD
replacement, the increase in coulomb measurement increased by 6% for PC 1 and 1% for
PC 2. At 10% CKD replacement, the increase in coulomb measurement increased by
16% for PC 1 and 13% for PC 2. At 15% CKD replacement, the increase in coulomb
measurement increased by 62% for PC 1 and 23% for PC 2. As per ASTM C1202, the
PC 1 concrete specimens with 0%, 5%, and 10% CKD were within the low range for
chloride permeability while the 15% CKD was in the moderate range. The chloride
permeability of the PC 2 concrete specimens with and without CKD replacement was in
the moderate chloride permeability classification. The author suggested that the increased
chloride content of the CKD may lead to a decrease in the electrical resistivity of
concrete which is reflected in an increase in chloride permeability. As the content of
CKD increases, more free chloride ions are liberated and cause the measure of chloride
permeability to increase.
122
Table 2.26 Chloride permeability of PC 1 and PC 2 with CKD 1 replacement at 0%, 5%,
10%, and 15% (Maslehuddin et al., 2008b)
Al-Harthy et al. (2003) used sorptivity (a measure of the capacity to absorb) and the
initial surface absorption test (ISAT) to measure the permeability characteristics of
different mortar samples containing CKD. Durability of mortar and concrete largely
depends on the ease with which fluids can enter and move through the material,
commonly known as permeability. Mixtures were prepared using CKD 3 at 0%, 10%,
20%, 25%, and 30% replacement level of PC 5 by mass. Al-Harthy et al. (2003)
gradually added water to each mix to maintain the same workability. Al-Harthy et al.
(2003) stated that the sorptivity and ISAT measurements both showed that the sorptivity
of mortar decreased with incorporation of CKD in the mortar mixtures. They further
noted that since sorptivity is a function of mixture strength, the higher the strength the
lower the sorptivity values. The use of CKD improved absorption properties and
therefore, can enhance durability. The authors attributed the lower sorptivity values to the
very fine particles of CKD, but did not elaborate on the nature of this mechanism. It is
assumed that the very fine particles could provide nucleation sites for enhanced cement
hydration and/or act as fine filler material between the cement grains.
A summary of the study conducted on the steel permeability effects of CKD-PC blends
compared to the respective reference plain cement is shown in Table 2.27.
123
Table 2.27 Permeability: from CKD-PC literature review
Author(s)
Blend Type w/b % CKD Replacement
General Effect on
Permeability
Author Suggested Mechanism(s)
Maslehuddin et al. (2008b)
CKD 1/PC 1 CKD 1/PC 2
C N.R. 0,5,10,15 ↑
(1) Increase in coulomb measured permeability may be due to presence of free chloride ions from CKD
Al-Harthy et al. (2003)
CKD 3/PC 5 M
V
0,10,20,25,30
↓ (2) Very fine particles of CKD.
P = Paste; M = Mortar; C = Concrete. V = varied w/b ratio to maintain consistent workability. N.R. = Not Reported
2.5.8.4 Freezing and Thawing
Batis et al. (1996) used PC 10 and two CKDs (CKD 9 and CKD 10) to study rapid
freezing and thawing resistance of concrete containing CKD. Each CKD was added as a
6% partial cement replacement at three w/b ratios: 0.50, 0.65, and 0.75. The concrete test
specimens were placed in a freezing and thawing test chamber and exposed to a
continuous 24-cycle with the following conditions: from 35ºC to -35ºC in three hours,
after that the temperature was kept constant at -35ºC for 3 hours, then it increased to 35ºC
at which it stayed for 1 hour. Each complete cycle lasted eight hours for a total of three
times per day. The mass loss of the specimens was measured at regular intervals of about
once per week. According to ASTM C666 (rapid freezing and thawing in water),
completion was defined at 300 cycles or when the average of percentage mass loss
exceeded 25% (whichever came first). Batis et al. (1996) reported that the CKD 10
concrete specimens had similar mass loss behaviour compared to the reference concrete
specimens at all three w/b ratios. The 6% CKD 9 concrete specimens had significantly
less resistance to rapid freezing and thawing compared to the reference concrete
specimens at all three w/b ratios.
124
Wang and Ramakrishnan (1990) conducted studies on the freezing and thawing
performance of concrete made with a binary blend consisting of 5% CKD (CKD 12) and
95% TIII cement (PC 12). The concrete mixes were tested at w/b ratios of 0.45, 0.52, and
0.55. Freezing and thawing performance was evaluated using two sets of two specimens
for each type of mix. One set was exposed to the conditions specified in ASTM C666
while the other was used as a reference. In addition to monitoring changes in fundamental
transverse frequency to calculate durability factors, changes in length and mass were also
recorded. Wang and Ramakrishnan (1990) concluded that the concrete specimens with
CKD did not show inferior resistance to rapid freezing and thawing in up to 120 cycles
(84 days), but experienced a little more mass loss thereafter compared to the plain cement
concrete specimens.
Ramakrishnan and Balaguru (1987) conducted an experimental investigation on the
freezing and thawing durability of concretes in which 5% of the cement was replaced
with CKD 11. Three types of cement were assessed: Type I (PC 15), Type II (PC 13), and
TIII (PC 14). Six sets of concrete with cement contents of 386 kg/m3 and 332 kg/m3 were
tested. The w/b ratio was 0.45 for the higher cement content and 0.52 for the lower
cement content. The air content ranged from 3.1 – 8.4%. The freezing and thawing tests
were conducted according to ASTM C666, using 100 x 100 x 375 mm prisms. Mass loss,
fundamental resonant transverse, frequency, and pulse velocity were measured at
approximate intervals of 30 cycles. The freezing and thawing tests were stopped at 300
cycles. Ramakrishnan and Balaguru (1987) concluded that under freezing and thawing
conditions, kiln dust (5% by mass) incorporated behavior is essentially similar to that of
plain PC concretes.
A summary of the studies conducted on the freezing and thawing effects of CKD-PC
blends compared to each of the respective reference plain cement is shown in Table 2.28.
125
Table 2.28 Freezing and thawing cycles: from CKD-PC literature review
Author(s)
Blend Type w/b % CKD Replacement
General Effect on Freezing and
Thawing Deterioration
Author Suggested Mechanism(s)
Batis et. al (1996)
CKD 9 / PC 10 CKD 10/ PC 10
C C
K K
0,6 0,6
↑ N.C.
Wang and Ramakrishnan (1990)
CKD 12/PC 12 C K 0,5 <120 cycles N.C. >120 cycles ↑
Ramakrishnan and Balaguru (1987)
CKD 12/PC 13 CKD 12/PC 14 CKD 12/PC 15
C C C
K K K
0,5 0,5 0,5
N.C. N.C. N.C.
P = Paste; M = Mortar; C = Concrete. V = varied w/b ratio to maintain consistent workability K = constant w/b ratio, but more than one w/b ratio was tested.
2.5.8.5 External Sulfate Resistance
Bhatty (1986) used a TI cement (PC 16) with three different CKDs (CKD 13, CKD 14,
and CKD 15) in mortars to investigate their effect on sulfate resistance (ASTM C1012).
The amount of CKD in each blend was fixed at 10% by mass of PC, with a w/b ratio of
0.45. Bhatty (1986) reported that the blends containing cement and CKD resulted in
expansions that were lower than cement alone. The author did not provide an explanation
for the improved sulfate resistance of the CKD blend. Improved sulfate resistance,
however, is often a result of lower permeability.
A summary of the study conducted on the external sulfate resistance effects of CKD-PC
blends compared to each of the respective reference plain cement is shown in Table 2.29.
Table 2.29 Sulfate resistance: from CKD-PC literature review
Author(s)
Blend Type w/b % Replacement Level
General Effect on External
Sulfate Resistance
Author Suggested Mechanism(s)
Bhatty (1986)
CKD 13/PC 16 CKD 14/PC 16 CKD 15/PC 16
M M M
0.45 0.45 0.45
0,10 0,10 0,10
↑ ↑ ↑
P = Paste; M = Mortar; C = Concrete.
126
2.5.8.6 Durability Summary
Although there are relatively few studies on CKD-PC blend durability, researchers have
stated the need to consider potential issues due to the composition of CKD (Wang et al.,
2002; Dyer et al., 1999). Since CKD is typically high in sulfur, alkalis, and chlorides,
there is the potential for external sulfate expansion, AAR, and steel corrosion. The impact
of using CKDs as a substitute of PC on microstructure and air content could affect
permeability and resistance to freezing and thawing cycles. One study on AAR reported a
potential increase for AAR using CKDs, while another study reported no impact.
Differences in expansion of CKD blends with similar alkali contents indicates that factors
other than alkali content – such as the type of alkali compound and/or the CKD-PC
chemical composition – can play a role in AAR. Steel corrosion increased as the amount
of CKD increased. A major contributor to steel corrosion can be the high chloride content
of CKD. The high alkali content of CKD, however, can help in maintaining the high
passivation film layer that protects steel. One study reported that permeability was
reduced with CKD, likely due to the presence of fine particles. Lower permeability
indicates higher durability. Three studies using blends with 5% and 6% CKD
replacement of PC reported no impact in four blends and increased mass loss in two
blends when exposed to freezing and thawing cycles. One study showed that CKD blends
improve resistance to external sulfate attack. Possible explanations for the freezing and
thawing and sulfate resistance effects of CKD blends were not provided.
127
3.0 MATERIALS AND EXPERIMENTAL DETAILS
This thesis consists of several experiments that were designed to provide data within the
context of two main objectives:
1. Investigate the characterization of CKDs using chemical, physical, mineralogical,
and dissolution analytical techniques
2. Establish an improved understanding of the effects of CKDs as partial substitution
for PC on:
a. heat of hydration
b. normal consistency
c. initial set time
d. compressive strength
e. expansion in limewater
f. soundness
g. ASR.
3.1 Materials
The materials used in this study were seven different CKDs (identified as A, B, C, D, D*,
E, and F) having a wide range of chemical/mineralogical and physical properties based
on different raw material sources and technologies, two filler materials (limestone
powder and ground silica), and two PCs of high and low alkali content (Cements TI and
TII, respectively). Each PC consists of only clinker and gypsum (pure PC). Limestone
powder (LS) and ground silica (inert) (SLX) were selected for comparison to the CKDs,
based on similar Blaine fineness.
128
All CKDs were fresh, as opposed to coming from a stockpile or landfill. The CKDs in
this study were selected to provide a representation of available CKDs in North America
from the three major types of cement manufacturing processes: wet, long-dry, and
preheater/precalciner, as shown in Table 3.1. The CKDs are from different cement plants
except CKDs D and D*, which are from the same plant. Only one sample from each
cement plant was planned but due to the uncharacteristically low Blaine fineness value of
the original sample (CKD D*), a second sample was collected (CKD D).
Table 3.1 CKD kiln process description
CKDs Kiln Process Dust Collection System
A Wet Electrostatic Precipitator
B Wet Bag-house
C Long-dry Electrostatic Precipitator
D, D* Long-dry Bag-house
E Precalciner (By-pass) Electrostatic Precipitator
F Precalciner (By-pass) Electrostatic Precipitator
Due to the length of the study, all materials were stored in plastic bags that were placed in
airtight plastic pails between uses. LOI was performed on all materials periodically to
ensure that (i) no moisture had been absorbed and (ii) they had not carbonated. LOI
results indicated that the materials did not change over time.
129
3.2 Testing of Raw Materials
3.2.1 Chemical Properties
The chemical compositions of the PCs were determined in accordance with ASTM C114.
X-ray fluorescence (XRF) was used to determine the major elements likely to be present
in PC, with the exception of moisture and carbon dioxide (CO2). The samples were de-
carbonized prior to XRF analysis using LOI. The LOI required igniting the dried sample
to a constant mass in a muffle furnace at 950 ± 50˚C in an uncovered porcelain crucible.
After the PCs had reached constant mass (in approximately 1 hour), samples were
prepared as fused beads using lithium borate. Fused beads were prepared by dissolving
the specimen in lithium borate at a high temperature (>1000˚C). Then the fused bead
samples were placed in the XRF spectrometer to determine the major elements. The
alkali, sulfate, and chloride contents for PCs from the XRF analysis were validated using
flame photometry, induction heating (LECO SC-432 Sulfur Analyzer), and
potentiometric titration. Water soluble alkali content was determined according to ASTM
C114. One gram of material is put in contact with water for 10 minutes and, after
filtration, the amount of water soluble alkalis contained in the aliquot was determined by
flame photometry. Some testing procedures developed for PC were modified to
accurately determine the chemical composition of the CKDs; these are described in
Section 4.1.1.
3.2.2 Mineralogical Properties
The free lime (free calcium oxide) test that is designed for PC (ASTM C114) using hot
benzoic acid titration was used for each PC and CKD. Mineralogical characterization of
all materials included X-ray diffraction (XRD) and thermal analyses. XRD was
performed with a Rigaku D/MAX 2000 diffractometer on pressed powder samples,
except CKD D, which was analyzed using PANalytical’s X’Pert PRO. Scanning was
performed in the range of 5º ≤ 2θ ≤ 65º with a scan rate of 0.02º 2θ per second. Powder
samples were analyzed using standard monochromatic CuKά radiation generated at
20mA and 40 kV. PC gypsum phases were obtained by differential scanning conduction
130
calorimetry (DSC) using the Mettler TA3000 System. CKD samples were analyzed by
thermo gravimetric analysis (TGA) in a nitrogen environment using a Netzsch STA 730
thermal analysis apparatus at a heating rate of 10˚C/minute.
3.2.3 Physical Properties
The relative density of each material was obtained by air-comparison pycnometer. The
relative density of the material is a required input in the calculation to determine the
Blaine fineness. The Blaine air permeability test (ASTM C204) and the percentage of
material finer than 45 µm (No. 325) sieve (ASTM C430) were used to determine the
fineness of all materials in this research program. The Blaine fineness test is the most
widely used method to assess the fineness of PC. The Blaine fineness test indirectly
measures the surface area of the cement particles per unit mass. Particle size distribution
(PSD) of all materials was also determined using the Malvern laser diffraction particle
sizer, 2600 Series. Although there is presently no standard specification for determining
the particle size distribution of PC, the cement industry commonly uses this test method
to determine fineness of materials. The usual procedures for measuring PC fineness were
slightly modified to accurately measure the fineness of the CKDs and fillers; these are
discussed in Section 4.1.3.
3.2.4 Dilute Stirred Suspensions
Dilute stirred suspensions were performed on each PC and CKD. A sample of each
material was mixed with water in a glass beaker with a water to solid ratio of 10. Each
mixture was stirred vigorously for 10 minutes by hand with a glass rod and the
temperature of the solution was maintained at approximately 23ºC. The solid material
was then separated using a vacuum filter. The liquid solution was placed in a sample tube
for analysis. Hyroxyl ion concentration was measured immediately for each sample. Then
the solution filtrate was brought to a pH of less than two using nitric acid. The purpose of
adjusting the sample pH to less than two was to minimize metal cation precipitation and
adsorption onto the sample container wall. It is known that nitric acid can also cause
131
certain elements from glass ampoules to become soluble. Therefore, appropriate plastic
ampoules were used to collect the samples. The balance of the cation and sulfide ionic
concentrations of each solution was determined by using Inductively Coupled Plasma
Atomic Emission Spectrometry (ICP AES) directly; the model used was the Perkin Elmer
Model Optima 3000DV ICP AEOS. The chloride ion concentration was approximated
using the U.S. Geological Survey public domain PHREEQC geochemical software
package.
3.3 CKD-PC Blends
For paste and mortar tests, the amount of CKD (CKD A, B, C, D, E, or F), limestone
powder, or silica flour in each blend was either 10% or 20% replacement of PC, by mass.
This resulted in 30 binder blends: 2 PC binder blends, 24 CKD-PC binder blends, and 4
PC-filler binder blends. All materials were sieved on a No. 20 sieve and weighed
accurately. Each blend was then homogenized by hand with a large spoon in a steel bowl
prior to the addition of water and/or fine aggregate (mortar sand). The paste and mortar
tests used in this study are described in Sections 3.3.1 to 3.3.7.
For concrete tests, the amount of CKD ranged between 7% and 13% replacement of PC,
by mass. CKD D was not available at the time of concrete casting, so the low Blaine
fineness CKD D* was used. The concrete CKD-PC blend tests are described in further
detail in Section 3.3.8.
3.3.1 Heat of Hydration
PC hydration leads to the evolution of heat and, consequently, isothermal conduction
calorimetry is commonly used to assess hydration kinetics of different paste blends. In
this study, the TAM Air isothermal conduction calorimeter was used to determine the
effects of the CKDs and fillers on the early hydration characteristics of the blends in
accordance with ASTM C1679. Eight samples can be analyzed at a time and an air
thermostat is used to maintain the isothermal temperature, which can be set between 15
132
and 60°C. The TAM Air utilizes heat conduction to transfer heat away from the sample
to a heat sink to keep the sample temperature essentially constant. The flow of heat,
caused by the temperature gradient across the sensor, creates a voltage signal
proportional to the heat flow. The heat output is calibrated by measuring the output from
a known heat source under identical conditions to the hydrating material. To minimize
disturbances from outside the calorimeter, an inert reference sample is used. The inert
sample is placed on a parallel heat flow sensor. Any external disturbances will influence
both the sample and the inert sample identically and be nullified. The detection limit of
the TAM AIR is 2 µW and the precision is specified to be ±10 µW. The time constant is
approximately 100 seconds. The results can be presented as either differential plots
showing the rate of heat evolution as a function of time or integral plots showing the total
amount of heat liberated as a function of time.
All materials were stored in tightly sealed plastic bags inside containers at a constant
temperature of 23 ± 2°C to pre-condition them prior to testing. Paste specimens with 150
g of solids and a w/b of 0.4 were prepared to study the heat of hydration at 23°C.
Distilled water was added to the solids and mixed for 2 minutes in a steel bowl using a
kitchen hand-blender at low speed. After 2 minutes, approximately 8 g of paste sample
were extracted from the bowl using a 10 ml syringe and injected into a glass ampoule. All
paste samples were weighed by mass difference between the glass ampoule with the
sample and the empty glass ampoule. The sample was then sealed and placed in the
calorimeter, five minutes after the distilled water was initially added. A corresponding
reference sample containing inert silica sand was also placed into the calorimeter. The
amount of silica sand was determined by calculating the equivalent specific heat capacity
to 8 g of PC paste. Heat of hydration for each paste specimen was measured over seven
days and performed in duplicate. The rates of heat evolution (mW/g) were measured and
recorded approximately every 10 seconds using a computer data acquisition system.
Since mixing of the constituents was carried out prior to introducing the sample into the
calorimeter, the first five minutes of heat evolution were not measured.
133
3.3.2 Normal Consistency
Normal consistency is a term that is used to describe the degree of plasticity of a freshly
mixed PC paste. The normal consistency (w/b ratio expressed as a percentage) was
determined for all binders in accordance with ASTM C187. For each binder blend, 650 g
of solid material were mixed with water to make a paste. The amount of water required to
bring the paste to a standard condition of wetness was regulated by the condition for
which the penetration of a standard needle (Vicat needle) into the paste is 10 ± 1 mm in
30 seconds. In order to gain appreciation for the accuracy of this test, ASTM C187
stipulates that the results of single-operator tests should not differ by more than 0.7%.
3.3.3 Initial Setting Time
The initial setting time is often used to evaluate if a paste is undergoing normal hydration
reactions. Initial setting time is defined as the time that elapses from the moment water is
added until the paste ceases to be fluid and plastic. Most PCs attain initial set within two
to four hours. For each binder blend, the paste that was mixed to determine normal
consistency was also used to determine initial set time. The time of initial setting of the
blended pastes was determined using a Vicat apparatus according to ASTM C191. The
time at which the needle penetrates 25 mm into the paste at room temperature was taken
to define the initial setting. ASTM C191 specifies that the penetration of the Vicate
needle in the paste should be checked 30 minutes after moulding and every 15 minutes
thereafter until a penetration of 25 mm or less is obtained. According to ASTM C191, the
single operator standard deviation has been found to be ±12 minutes within a range of 49
to 202 minutes initial setting time. To increase the accuracy of the initial set time
measurement, the test procedure was modified by increasing the frequency of the Vicat
penetrations to every five minutes as the paste approached initial set.
134
3.3.4 Flow
Flow is used to describe the relative mobility (ability to flow) of mortar. The flow for
each binder blend was determined on a flow table as described in ASTM C230. Mortars
were mixed in accordance with ASTM C305 with one part of binder blend, 2.75 parts of
graded sand, and deionized water. Mortars were mixed for each binder blend to
determine (i) the flow at a fixed w/b ratio of 0.485 and (ii) the water demand to yield a
flow of 110 ± 5 according to ASTM C1437. ASTM C1437 states that the results of
properly conducted tests should differ by no more than 11% for single-operator testing.
3.3.5 Compressive Strength
Compressive strength is the most commonly used method to assess cement quality. The
compressive strength for each binder blend was determined according to ASTM C109
(CSA A456.2-C3) at 1, 3, 7, 28, and 90 days. 50 mm mortar cube specimens were
prepared by mixing one part of binder blend material, 2.75 parts of graded sand, and
deionized water addition (w/b ratio of 0.485). The specimens were cured in a humidity
chamber at 23±1 °C for 24 hours, then demoulded and immersed in lime saturated water
until tested. The compressive strength result is the average of three test specimens from a
single batch at the specified curing time. ASTM C109 states that when three cubes
represent a test age, the maximum permissible range between specimens from the same
mortar batch at the same test age is 8.7% of the average.
3.3.6 Expansion in Limewater
ASTM C1038 is a test method that is used to determine the expansion of mortar bars
made from PC in saturated limewater. The amount of expansion is typically related to the
amount of calcium sulfate in the PC. In this study, ASTM C1038 was used to assess the
expansion of all binder blends. Mortars were mixed in accordance with ASTM C305 with
one part of binder blend, 2.75 parts of graded sand, and deionized water. The amount of
water required to yield a flow of 110 ± 5 according to ASTM C1437 was used for each
binder blend. Four mortar bar specimens (25 x 25 x 285 mm) were prepared for each
135
binder blend and the expansion was calculated as the mean of four mortar bars. The test
method specifies calculating the difference in length of specimens at 24 hours from the
time the binder blend was mixed with water and at 14 days. The length change of the
mortars made from different blends, however, was also measured up to one year for most
blends. An expansion limit of 0.020% in 14 days of limewater immersion is in use in
CSA A3001.
3.3.7 Autoclave Expansion
Soundness refers to the ability of a paste to retain its volume after it has set. Unsoundness
can arise from excessive amounts of hard burned free lime or free magnesia and has the
potential to cause delayed destructive expansion. In the autoclave expansion test (ASTM
C151), a cement paste specimen (25 x 25 x 285 mm) is placed in an autoclave for three
hours at 2 MPa and approximately 216°C. The difference between measurements of the
specimen taken before and after the autoclave treatment represents the expansion due to
unsoundness. The autoclave expansion test method was used to measure expansion due to
the combined effects of both magnesia and free lime for each binder blend. For each
binder blend paste, the same w/b ratio used to attain normal consistency and initial setting
time was used for the autoclave test. ASTM C151 states that the results of two properly
conducted tests by the same operator for expansion of similar batches should not differ
from each other by more than 0.07% expansion.
3.3.8 Alkali Silica Reactivity
The concrete prism test is typically used to evaluate the reactivity of aggregate with
respect to ASR and also to examine the impact of materials that may be introduced to
suppress the expansion due to ASR. The typical test period for evaluating the reactivity
of an aggregate is one year, and at least two years with SCM (CSA A23.2-14A and
ASTM C1293). For the proposed research study, this test method was modified to assess
the direct impact on ASR when using CKD as a partial replacement of PC. The main
136
purpose of this study was to make relative comparison of the binary blends rather than
obtaining the absolute values.
The materials used for the ASR concrete durability study were six different CKDs (A, B,
C, D*, E and F) and two PCs of high and low alkali content (TI and TII). CKD D and the
fillers were unfortunately not available at the time of casting for the concrete prisms. Two
series of concrete prisms were cast to assess the effect of CKDs on ASR with Cements TI
and TII. The reactive aggregate susceptible to ASR that was used in this study is Sudbury
aggregate.
The w/b ratio for all mixes was in the range of 0.42 – 0.45 to maintain a constant slump.
The three equal reactive coarse aggregate fractions by mass were of 10, 15, and 20 mm
nominal maximum diameter, respectively. The specific gravity of the reactive coarse
aggregate was 2.71. The fine aggregate had a fineness modulus of 2.90 and a specific
gravity of 2.68. The freshly mixed concrete was tested for slump (ASTM C143), air
content (ASTM C231, pressure method), and unit mass (ASTM C138). Two concrete
cylinders measuring 100 x 200 mm were prepared from each batch. The cylinders were
stored moist at 38 ºC and tested for compressive strength at 28 days. Four concrete
specimens from each batch were prepared, measuring 75 x 75 x 300 mm. The expansion
of the concrete specimens was measured every three months for a period of 365 days.
For each concrete mixture investigated, the expansion (length change divided by the
gauge length) was calculated as the mean of four concrete prisms. Mass was also
measured for each concrete prism and the mass change was averaged for the four prisms.
ASR Test Series 1: The first set of concrete prisms was cast using 10% replacement of
Cement TI with CKD binders (CKD and/or PC). The total alkali content of the concrete
was increased to 1.25% Na2Oe of binder mass by adding sodium hydroxide (NaOH) to
the mixing water. Cement TI as the binder material alone was used in two control
mixtures (Cements TI CTL 1 and CTL 2). The total solid binder was 420 kg/m3 for each
137
mix except for Cement TI CTL 2, which was 378 kg/m3. Cement TI CTL 2 contained the
same amount of PC as in the concrete blends with CKDs. Due to the reduction in solid
binder material, the Cement TI CTL 2 alkali level was increased to 1.38% Na2Oe of
binder mass to give the same total alkali loading as the other blends in Test Series 1.
ASR Test Series 2: The second set of concrete prisms was cast using Cement TII and
varying amounts of PC replacement with CKDs. A constant amount of NaOH was added
to each mix. The total alkali content of the concrete was increased to 1.25% (Na2Oe) of
cement mass by adjusting the amount of CKD replacement in each mix. The amount of
NaOH addition to each mix was selected to maintain the range of CKD replacement
levels generally close to 10%. The total solid binder for each mix was 420 kg/m3. Cement
TII as the binder material alone was used in two control mixtures (Cements TII CTL 1
and CTL 2). Cement TII CTL 2 alkali content was raised using NaOH to a level of 1.03%
Na2Oe of binder mass, rather than the 1.25% of alkali loading to give the same total alkali
loading contribution of NaOH as the other CKD blends in Test Series 2.
138
4.0 RESULTS AND DISCUSSION
4.1 Material Characterization
The first objective of this thesis was to characterize the seven CKDs, two PCs, and two
filler materials. It was found that some of the analytical methods designed for PC do not
always provide accurate compositional analysis for CKDs. Therefore, the analytical
methods required for accurate analysis of CKDs were identified. The complete chemical
analysis and physical properties (relative density, Blaine fineness, and percentage of fine
material below 45 µm) of all materials were performed. In addition to the chemical
composition and standard fineness tests, quantitative mineralogical compositions, particle
size distributions, and dilute stirred suspension analyses were also performed.
4.1.1 Chemical Properties
The characteristics of materials used in cement are traditionally evaluated by an oxide
composition based on chemical analysis data. Chemical makeup of a CKD and PC can
provide an important indicator of how the CKD-PC blend will perform. It was found that
there are very few published works with complete chemical analysis of CKDs in the
research of CKD-PC blends. The incomplete CKD chemical composition data provided
in previous studies is likely due in part to the application of analytical procedures that are
specifically designed for PC, rather than CKDs.
The chemical compositions of the two PCs were determined in accordance with ASTM
C114 using X-ray fluorescence (XRF), as stated in Chapter 3. Prior to XRF analysis, loss
on ignition (LOI) was performed by igniting the 110˚C dried sample to a constant mass in
a muffle furnace at 950 ± 50˚C in an uncovered crucible for 1h. The LOI values obtained
result from either exposure to moisture or CO2 (since each of the two PCs only consists
of clinker and gypsum, there is no contribution of CO2 from carbonate additions).
139
CKDs usually take between 12 to 24 hours to reach constant mass at 950 ± 50 ˚C. The
LOI for CKDs not only reflects prehydration and decarbonization, but also the presence
of volatiles (alkali, sulfate, and/or chloride). The ranges of volatilization at the melting
point of compounds found in CKDs are shown in Table 4.1. A large percentage of the
CKD volatiles will be released from the sample into the atmosphere during the LOI test
and during preparation of the fused beads since they are less stable in CKDs than in PC at
950 ± 50 ˚C. This presents two problems: (i) the LOI is not just CO2 and (ii) the XRF
quantification of alkali, sulfate, and/or chloride is underestimated. Therefore, direct
testing procedures developed for PC in ASTM C114 were used to accurately determine
the volatile composition of the CKDs (Babikan and Verville, 2007). The test methods
used to measure the volatiles of CKDs were: flame photometry for alkalis, induction
heating for sulfate, and potentiometric titration for chloride. The XRF chemical analysis
values were then corrected by accounting for the volatiles that were released during the
LOI test. The process that was used for chemical analysis of the CKDs is described in
Figure 4.1. The CKD chemical composition calculations are presented in Appendix A.
Table 4.1 Melting points and volatility of compounds in CKDs (Manias, 2004)
(Note: This table is the same as Table 2.3)
Volatile Compounds Melting Point, ˚C Range of volatility*, %
CaCl2 772 60 to 80
KCl 776 60 to 80
NaCl 801 50 to 60
Na2SO4 884 35 to 50
K2SO4 1069 40 to 60
CaSO4 1280 ---
*Range of volatility: % of compound that will volatilize at melting point
140
Figure 4.1 Process flow chart for CKD chemical composition analysis
The free lime test for PCs is typically used to determine the free calcium oxide content.
This test, however, is also sensitive to calcium hydroxide. The free lime test gives the
total of free calcium oxide plus calcium hydroxide contents and does not differentiate
between the two. This is generally not an issue for PC free lime analysis since the
presence of calcium hydroxide is rare (except in PC that consists of weathered clinker).
CKDs, however, can be exposed to moisture during processing to reduce fugitive dust
and/or storage outside. Therefore, the results from the free lime test for CKDs should be
considered as representative of the combined free calcium oxide and calcium hydroxide
contents.
CKD Sample
CKD Sub-sample 1
CKD Sub-sample 2
CKD Sub-sample 3
CKD Sub-sample 4
LOI and XRF
Analysis
Calculate chemical composition by
accounting for volatiles
released during LOI test
Chloride Content: Potentiometric
Titration
Sulfate Content: Induction Furnace
Alkali Content:
Flame Photometry
141
The chemical and standard physical properties (relative density, Blaine fineness, and fine
material below 45 µm) of all materials are shown in Table 4.2. Cement TI met the
specifications for normal PC and is characterized by a relatively high sulfate (4.35%),
high total alkali content (0.97%), and high C3A content (11.3%). Cement TII met the
specification for a moderate sulfate resistant cement and is characterized by its low C3A
(6.1%) and low total alkali (0.57%) contents. The data in Table 4.2 shows the LS and
SLX to consist of 95.52% calcite based on 53.49% / 56.00% CaO (by LOI, 42.29% /
44.00% = 96.11%) and 98.15% quartz, respectively.
Comparison of the current CKDs to those from previous research studies as summarized
by Sreekrishnavilasm et al. (2006) (Table 2.5) shows that all CKDs were within the
maximum-minimum range of the compositions, except for the free lime values for CKDs
E and F. CKDs A, B, and C appear to be particularly similar to those in the previously
published literature. CKDs A and C were within the standard deviations for each
parameter. CKD B had concentrations of calcium oxide, silicon dioxide, and aluminum
oxide slightly outside the respective range for standard deviation. CKDs D*, D, E, and F,
however, appear to be slightly different from the published dataset. CKDs D*, D, and E
each had values for sulfate above the range for standard deviation. CKDs D*, E, and F
had higher free limes than the upper limit of the standard deviation. CKDs E and F also
had calcium oxide and magnesium oxide contents above the respective ranges for
standard deviation. The chloride levels of the CKDs within this study appear to be lower
than the full range of chloride levels found in CKDs from previous studies.
As a note of interest, the CKD oxide composition statistical analysis of intermittent daily
samples collected over a 3 year period from the same kiln source as CKD C is presented
in Table 2.9. Although more variable than PC, the standard deviation results indicate that
the CKD from this kiln source is quite consistent.
142
Table 4.2 Chemical and select physical components of PC, CKD, and filler materials
(mass %)
PCs Cement Kiln Dusts (CKDs) Fillers
Wet Long-dry PH/PC
Components TI TII A B C D* D E F LS SLX
CaO 62.03 63.06 44.32 32.70 44.75 51.12 45.51 55.18 55.86 53.49 0.02
SiO2 19.15 20.39 14.25 24.07 14.30 14.23 14.41 15.25 16.81 2.60 98.15
Al2O3 5.83 4.21 3.77 9.12 4.02 4.05 4.93 3.78 3.94 0.68 0.47
Fe2O3 2.46 3.01 1.92 3.78 1.60 2.05 2.16 2.26 1.94 0.21 0.06
MgO 2.18 3.21 1.80 1.82 1.02 2.00 1.68 2.85 3.08 0.55 0.00
SO3 4.35 2.98 3.03 5.79 7.30 15.05 16.15 11.75 8.97 0.03 0.03
Na2O 0.30 0.13 0.60 0.53 0.19 0.40 0.66 0.26 0.32 0.02 0.01
K2O 1.01 0.69 3.35 4.81 3.20 3.32 4.47 4.83 3.66 0.21 0.08
Na2Oea 0.97 0.58 2.80 3.69 2.30 2.58 3.60 3.43 2.73 0.16 0.06
Na2O soluble 0.16 0.06 0.38 0.30 0.10 0.21 0.39 0.17 0.14 0.00 0.00
K2O soluble 0.97 0.64 2.66 3.88 1.97 2.13 2.9 3.94 2.42 0.00 0.00
Na2Oeb soluble 0.80 0.49 2.13 2.85 1.40 1.61 2.30 2.76 1.73 0.00 0.00
Na2Oeb / Na2Oe
a 0.82 0.84 0.76 0.77 0.61 0.62 0.64 0.80 0.64 0.00 0.00
Ti2O 0.25 0.26 0.40 0.55 0.21 0.24 0.26 0.24 0.19 0.03 0.03
P2O5 0.26 0.12 0.12 0.11 0.04 0.12 0.15 0.11 0.09 0.01 0.01
Mn2O 0.09 0.56 0.06 0.06 0.05 0.11 0.08 0.50 0.06 0.01 0.00
Cl- 0.00 0.00 2.49 0.94 0.38 0.22 0.35 2.18 0.85 0.00 0.00
LOIc 1.79 1.28 28.74 17.85 23.76 8.23 9.96 5.88 5.47 42.29 0.20
Total Sum (High)d 99.92 99.88 104.95 102.15 100.84 101.16 100.83 105.07 101.27 100.15 99.06
Total Sum (Real)e 99.92 99.88 99.08 99.79 99.73 100.31 100.02 99.74 99.34 100.15 99.06
Free Limef 0.70 1.53 4.50 4.04 5.70 18.20 10.59 29.20 38.20 0.00 0.00 a Equivalent Alkali (Na2O + 0.658 K2O) b Equivalent Water Sol. Alkali (Water Sol. Na2O + 0.658 Water Sol. K2O) c Loss on ignition determined at 950 ± 50 ºC d XRF sum of total oxides e Sum of total oxides calculated by removing the volatiles that are included in the LOI (Na2O, K2O, Cl-) f Free lime: combined CaO & Ca(OH)2 content
Each CKD has its own characteristics, but there can be some generalization of these
particular CKDs based upon the pyroprocess, especially in free lime and chloride
contents. As expected, the wet and long-dry kilns had free lime contents that are lower
than the precalciner kilns. CKDs D* and D have higher free limes than typical long-dry
kiln CKDs due to unique equipment design in the kiln, but they are still lower than the
precalciner CKDs E and F free limes. The long-dry kiln CKDs have low chloride and
high sulfate contents in comparison to the wet and precalciner CKDs.
143
The CKDs were generally higher in total alkali, sulfate, chloride, LOI, and free lime than
Cements TI and TII, as shown in Table 4.1. Water soluble alkalis are not normally
reported for PCs, although the test method is described in ASTM C114. The CKDs
contained higher levels of water soluble alkalis than the Cements TI and TII. It is
interesting to note that although the quantity of soluble alkalis is higher in CKDs, the
ratio of water soluble alkalis to total alkalis is higher in Cements TI and TII.
Statements/Observations:
4.i The ASTM C114 techniques specified for PC chemical analysis are not
necessarily sufficient and/or appropriate for CKD chemical analysis. The mass
of CKD at 950 ± 50 ˚C is not stable until 12 – 24 hours. Therefore, the 1-hour
PC standard LOI test duration is not sufficient to determine LOI for CKDs.
Further, LOI and fused bead preparation of CKDs can cause the volatile
compounds to be released into the atmosphere prior to chemical composition
analysis. Babikan and Verville (2007) recommend using the following tests in
ASTM C114 to determine the chemical composition of CKD volatile
elements:
i. Alkalis: flame photometry
ii. Sulfates: induction furnace
iii. Chloride: potentiometric titration
4.ii Although PC typically only contains free calcium oxide, the PC free lime test
is representative of both free calcium oxide and calcium hydroxide. CKDs are
more likely to contain calcium hydroxide than PC due to exposure to moisture
during handling and storage.
144
4.1.2 Mineralogical Properties
CKD mineralogical analysis (determination of the relative abundance of the different
phases) is an essential complement of the chemical analysis. The effects of CKD
elements in a CKD-PC blend may vary depending on the form in which they actually
exist. The characteristics of CKD are traditionally evaluated based on chemical analysis
data. Such data does not, however, indicate the ways in which the different elements
actually exist within the CKD and how they might be expected to react during hydration.
Soluble alkalis, for example, may occur as separate crystalline phases in the form of
alkali chlorides or alkali sulfates. The reactivity of elements may, therefore, be expected
to vary, depending on the form in which they actually exist.
The traditional methods (Bogue equations, XRD Rietveld analysis, and thermal analysis)
were used to assess the PC mineralogical compositions. Although quantifying the
mineralogical composition of PC has been thoroughly explored, the data to quantify the
mineralogical phases of CKDs is relatively limited. Mineralogical analysis of CKDs has
not been thoroughly evaluated due to a lack of quantitative analytical techniques. A
method for mineralogical phase quantification of CKDs using XRD diffraction scans,
Rietveld refinement, and physical tests (thermal analysis and titration) is introduced in
this section.
145
Rietveld analyses of Cements TI and TII were performed using the X-ray diffraction
scans and control files developed “in-house” at Lafarge North America. The
mineralogical compositions of the PCs were determined by Rietveld quantitative X-ray
diffraction analysis, shown in Table 4.3(a). Alite (impure C3S) typically contains 3 – 4%
of substituent oxides, the most significant of which are iron, magnesium, and aluminum.
Belite (impure C2S) may contain 4 – 6% of substituent oxides of which aluminum and
iron are most common (Taylor, 1997). The potential proportions of C3S, C2S, C3A, and
C4AF compounds in each PC, calculated based on the Bogue equations in ASTM C150,
are shown in Table 4.3b. Taylor (1997) has noted that Bogue calculations can differ
considerably from the true phase compositions, especially by underestimation of alite and
overestimation of belite because the actual composition of these phases differs
considerably from those of the pure form.
Table 4.3 Cements TI and TII mineralogical composition (mass %) (a) XRD Rietveld Analysis (b) Bogue Compound Calculation
Phase TI TII Phase TI TII
Alite, C3S 68.6 66.5 C3S 51.9 60.7
Belite, C2S 10.3 15.2 C2S 15.8 12.6
Aluminate, C3A 8.7 3.0 C3A 11.3 6.1
Ferrite, C4AF 7.5 8.9 C4AF 7.5 9.1
Lime, CaO 0.0 0.2
Periclase, MgO 1.4 2.5 Gypsum, CaSO4·2H2O 1.7 1.0
Hemihydrate, CaSO4·0.5H2O 0.5 0.6
Anhydrite, CaSO4 0.2 0.9
Calcite, CaCO3 0.7 0.8
Portlandite, Ca(OH)2 0.1 0.4
Quartz, SiO2 0.3 0.2
146
Cement TI has considerably more gypsum (readily soluble calcium sulfate) than Cement
TII. PC with high aluminate contents typically require a sufficient amount of added
calcium sulfate as a set controlling agent, which increases the sulfate content of the PC. It
follows that cements low in aluminate require less added calcium sulfate and would tend
to have lower sulfate contents.
Thermogravimetric analysis (TGA) is ideally suited to quantify the degree of calcination
and amount of calcium hydroxide (portlandite) present in CKDs. Samples were tested in
a temperature range from 30˚C to 950˚C. Portlandite decomposed between 400 to 530˚C
and calcium carbonate was detected between 700 to 850˚C. The TGA results for Cements
TI and TII and the CKDs are presented in Appendix B. An approximate determination of
portlandite (Ca(OH)2) was established using mass balance calculations and the TGA
results. The portlandite was then subtracted from the total free lime (calcium oxide and
calcium hydroxide) in Table 4.2 (based on equivalent calcium oxide) to determine the
free calcium oxide (CaO) portion. The mineralogical composition of calcite, portlandite,
and free calcium oxide is shown in Table 4.4.
Table 4.4 CKD mineralogical compositions using direct test methods (mass %)
Components Cement Kiln Dusts (CKDs) A B C D* D E F
CaCO3 52.6 34.7 51.3 17.3 22.7 1.8 6.5 free CaO 4.5 4.0 5.7 18.2 10.6 28.4 34.5 Ca(OH)2 0.0 0.0 0.0 0.0 0.0 1.0 4.9
147
Rietveld XRD analysis was used to accurately estimate the overall mineralogical phases
quantification of each CKD. The CKD crystal phases were identified using XRD scans
and Joint Committee on Powder Diffraction Standards (JCPDS) files. CKDs typically
contain some phases that cannot be observed by XRD. Clay minerals, glass, and similar
poorly crystalline components fall into this class and are called amorphous (without form
or crystal structure). Different types of amorphous materials, however, may provide an
indication of their presence as broad patterns or “humps”. X-ray powder diffraction is
only sensitive to crystalline materials.
During normal Rietveld analysis, the amorphous component of a sample is not
considered and the relative mass fractions of the crystalline phases are normalized to
100%. This was corrected using a known amount of either calcite or free lime determined
by TGA, as shown in Table 4.4. In deciding which phase quantity to use, the best fit
results were achieved using the most abundant phase for each respective CKD Rietveld
Refinement. Therefore, CKDs A, B, C, and D were quantified relative to their calcite
value, and CKDs D*, E and F were quantified relative to their free calcium oxide content.
Adding the known mass of the phase to the Rietveld analysis allowed the amorphous
phase to be incorporated in the analysis. Furthermore, absolute mass fractions were
obtained for all phases. The results of the quantitative phase analyses using TGA, XRD,
and Rietveld are shown in Table 4.5. The XRD scans are presented in Appendix C.
Calcite was identified as the major phase for CKDs A (52.6%), B (34.7%), C (51.3%),
and D (22.7%), which are from the wet and long-dry processes. Free lime is the dominant
phase in CKDs D* (18.2%), E (28.4%), and F (34.5%). CKDs E and F are from
precalciners, while CKDs D and D* have uncharacteristically high free limes for a long-
dry kiln process. Quartz was present in all CKDs in a range from 3 – 11%. Periclase was
present at approximately 2% for CKDs E and F, but less than 1% for the other CKDs.
CKDs A and B contained minor amounts (≤5%) of dolomite. CKDs E and F had minor
amounts of portlandite, while CKD B had only trace amounts. CKDs E and F are from
148
precalciner kilns that are equipped with water conditioning towers to reduce CKD
fugitive dust. The water from the conditioning tower converts a portion of the free lime to
calcium hydroxide.
Table 4.5 Mineralogical composition of CKD and filler materials (mass %)
Cement Kiln Dust
Wet Long-dry PH/PC
Category Phase CKD A CKD B CKD C CKD D* CKD D CKD E CKD F
Calcite, CaCO3 52.6 34.7 51.3 15 22.7 1 4
Quartz, SiO2 9 7 11 4 3 7 6
Dolomite, CaMgCO3 5 3 - - 1 - - Raw Feed
Periclase, MgO <1 <1 <1 <1 <1 2 2
Alite, C3S 1 - 1 6 2 2 <1
ß-Belite, C2S 22 8 11 7 6 14 4
Aluminate, C3A <1 <1 <1 <1 <1 1 <1
Clinker Phases
Ferrite, C4AF <1 <1 <1 <1 - 2 <1
Lime, CaO 4 3 5 18.2 12 28.4 34.5 Free Lime Portlandite, Ca(OH)2 - <1 - - - 1 3
Anhydrite, CaSO4 2 2 5 12 18 14 6 Calcium Langbeinite,
2CaSO4.K2SO4 - - 2 4 3 1 1 Aphthitalite, K3Na(SO4)2 - <1 - - 2 - -
Arcanite, K2SO4 - 2 <1 - - <1 <1
Sulfates
Calcium Sulfoaluminate,
(AFt, AFm) - - 1 1 <1 1 <1
Chlorides Sylvite, KCl 3 1 <1 - <1 4 <1
Calcium Chloride,
CaCl2 - - <1 - - - -
Amorphous <1 32 11 31 29 18 35 Akermanite,
Ca2Mg(Si2O7) - - - - - 1 - Calcium
Dialuminum Oxide, CaAl2O4 - - - - <1 1 1
Clays, Raw
Materials (slag, fly ash), &
Intermediate Phases
Mullite, Al6Si2O13 - 4 - - - - -
Note: All values are from XRD analysis except those that are in bold
149
Each CKD consisted of some or all of the four major PC phases. The total sum of cement
phases in the CKDs ranged between 4% (CKD F) and 25% (CKD A). Belite was the
most prevalent PC phase in each CKD within a range of 4% and 22%. Each CKD
contained alite in a range between <1% and 2%, with the exception of the
uncharacteristic CKD D* which had 6%. All of the CKDs except CKD E had aluminate
and ferrite each with <1%. CKD E had higher amounts of aluminate (1%) and ferrite
(2%).
Anhydrite was present in all CKDs, with the highest amounts in CKDs D* (12%), D
(18%), and E (14%). Alkali sulfate salts were present in all seven CKDs. Calcium
langbeinite was found in all CKDs except CKDs A and B, in a range of 1% and 4%.
CKDs B, C, E, and F each contained arcanite in a range of <1 – 2%. Aphtithalite was
identified in CKDs B (<1%) and D (2%). Calcium sulfoaluminate, which reacts readily
with water, was present in small amounts (<1 – 2%) in all CKDs, except CKDs A and B.
CKDs A and E contained sylvite ≥3%, while CKD B contained 1%. Small amounts of
sylvite (<1%) were present in CKDs C, D, and F, while no traces of sylvite were found in
CKD D*. CKD C was the only sample found to contain calcium chloride (<1%).
Amorphous material is mostly a reflection of clay minerals, partially dehydrated clay
minerals, and/or supplementary raw materials such as fly ash or slag. CKDs B, D*, D,
and F had amorphous contents within a range of 29% and 35%. CKD E contained 18%
and CKD C had 11% amorphous content. CKD A had very little amorphous material
(<1%). Small amounts of calcium dialuminum oxide were found in CKDs D, E, and F
(≤1%). CKD E contained akermanite (1%) and CKD B contained mullite (4%).
Akermanite, calcium dialuminum oxide, and mullite are phases typically found in
alumina supplementary raw material sources. Akermanite is typically found in slag and
mullite is typically found in fly ash.
150
X-ray diffraction techniques were developed to determine the composition of the CKDs.
The composition and quantity of the crystalline and amorphous phases of the seven
CKDs differed significantly. The type of crystalline material and the relative proportion
of the amorphous and crystalline material in CKDs can significantly affect the hydration
of a CKD-PC blend. Also, previous literature studies have not identified significant
amounts of calcium langbeinite in CKDs. Tang and Gartner (1988) have reported on the
effects of calcium langbeinite on PC hydration. They concluded that calcium langbeinite
is a more effective retarder of C3A than either gypsum or pure alkali sulfates alone. The
proposed mechanism takes into account the rate at which the sulfate phases can supply
both calcium and sulfate ions to the surfaces of the aluminate phases during early stage
hydration. The presence of calcium langbeinite increases the rate and chemical potential
at which calcium sulfate enters into solution. Finally, although not previously reported, it
appears CKDs can contain fly ash and/or slag if these materials are used as raw meal in
clinker production. CKD B contains mullite (typically found in fly ash) and CKD E
contains akermanite (typically found in slag).
Statements/Observations:
4.iii Fresh CKDs from precalciners may contain portlandite due to the combination
of high free lime and the use of water sprays used to condense materials in the
preheater gas stream. TGA can be used to determine the CKD calcium
hydroxide content.
4.iv Preheater/precalciner CKDs have very high free limes (28 – 35%) compared
to CKDs from wet (3 – 4%) or long-dry (5 – 18%) processes.
4.v XRD and Rietveld refinement, combined with TGA and the free lime test, can
be used to quantify the actual CKD crystalline composition and amorphous
content.
151
4.vi The amorphous and/or clinker phase contents in CKDs can be as high as
approximately 23% and 35%, respectively.
4.vii CKDs can contain calcium langbeinite (up to approximately 4%). Calcium
langbeinite is readily soluble and can provide excess sulfate to the system
causing early precipitates to form, such as syngenite and secondary gypsum.
This can lead to observable changes in workability.
4.viii Fly ash and/or slag may also be present at low levels (1 – 4%) if used as raw
materials in clinker production. CKD B contains mullite (typically found in
fly ash) and CKD E contains akermanite (typically found in slag).
4.1.3 Physical Properties
Important physical properties required to understand the behaviour of binder blends using
CKD, PC and fillers are relative density, fineness, and particle size distribution. The
relative density, Blaine air-permeability (ASTM C204), and the percent passing a 45 µm
sieve are traditional methods that were used to characterize the fineness of all materials in
this research program; they are shown in Table 4.6. The usual procedures used to
measure PC fineness were slightly modified to accurately measure the fineness of the
CKDs and fillers. These modifications are described in this section. The particle size
distribution (PSD) analysis is more recently developed technology that was also used.
The PSD results are presented in Figure 4.2 and Figure 4.3. The mean particle size or D50
(the equivalent diameter where 50% by volume of the particles has a smaller diameter
and hence the remaining 50% is coarser) and D10 (the equivalent diameter where 10% by
volume of the particles has a smaller diameter and hence the remaining 90% is coarser)
for all materials are also presented in Table 4.6.
152
Table 4.6 Physical properties of all materials
PCs Cement Kiln Dusts (CKDs) Fillers
Wet Long-dry PH/PC
Properties TI TII A B C D* D E F LS SLX
Relative Density 3.11 3.18 2.75 2.65 2.77 2.89 2.86 2.97 2.82 2.71 2.66
Blaine (m2/kg) 367 377 654 684 681 177 610 350 526 488 638
45µm (% passing)a 95.74 92.01 73.30 63.10 71.10 56.90 87.23 69.00 74.90 99.54 98.09
D50 (µm) 15.51 14.37 14.09 18.31 13.73 36.98 9.71 22.58 15.99 9.22 11.42
D10 (µm) 3.40 2.98 2.25 2.19 1.91 8.62 2.13 4.39 2.35 1.57 1.36 a Fineness: determined as material finer than 45µm mesh sieve
The relative densities of Cements TI (3.11) and TII (3.18) are fairly close to the generally
accepted average value of 3.15 for PCs in ASTM. The relative densities of the CKDs
range between 2.65 and 2.97, which is lower than PC. As a result, if CKD is used as a
partial replacement of PC by mass, a larger volume of CKD particles will replace the PC
particles removed (assuming the CKD particles are equivalent in size to the PC particles)
and the volume of paste will increase. The filler relative densities were in the lower range
of the CKD relative densities.
In order to attain accurate Blaine fineness results, the measured density for all CKDs and
fillers was used for the Blaine analysis calculations, rather than the standard 3.15
specified in ASTM for PCs. Also, although PCs typically do not require it, ultrasound
treatment was used for all materials during particle size laser diffraction. Since particle
size laser diffraction is not able to differentiate between individual particles and
agglomerated particles, some fine powders used in the cement industry that have a higher
tendency for agglomeration, such as silica fume, require ultrasound treatment. CKDs can
have very fine particles that agglomerate affecting the accuracy and precision of the PSD
analysis.
153
Cements TI and TII have similar Blaine fineness values to other commercially available
PCs given by Tennis and Bhatty (2006). The Blaine fineness values for CKDs A (654
m2/kg), B (684 m2/kg), C (681 m2/kg), and D (610 m2/kg) are similar, while Blaine
fineness values for CKDs E (350 m2/kg) and F (488 m2/kg) are lower. CKDs E and F
come from preheater/precalciner kiln systems, which are reported to generate coarser
CKD than wet and long-dry processes. CKD D* has an uncharacteristically low Blaine
fineness (185 m2/kg) for a long-dry kiln and is not considered typical. All CKDs had
higher Blaine fineness values than Cements TI and TII except CKDs D* and E. The
percentage of materials passing 45 µm sieve for the TI and TII were 95.74% and 92.01%,
respectively. Each CKD had considerably lower percentage of material passing the 45
µm sieve, with the range being between 56.90% and 87.23%. The CKDs may have a
broader particle size range than found in the PCs since the CKDs are not selected based
upon size through a separator. The percentage passing 45 µm sieve for LS (99.54%) and
SLX (98.09%) are slightly higher than for the PCs.
The full range of particle size distribution for all materials is shown in Figure 4.2.
Cements TI and TII have very similar particle size distributions. The overall trend
indicates the CKDs generally straddle both sides of the PCs. The black arrow indicates
that in the area of larger particles (between 10 µm and 100 µm), CKDs A, B, C, D*, E,
and F, are coarser than the PCs. Both fillers appear to be finer than the PCs. Figure 4.3 is
a plot of the particle size distributions up to 10 µm (finer particles). CKDs A, B, C, D,
and F appear to have more fine particles than PC or fillers.
154
The Blaine fineness values reflect that the CKDs are generally finer than the PCs, but the
percentage passing 45 µm sieve values indicate that the CKDs are coarser than the PCs.
The PSDs help to explain the reasons for the conflicting results. The correlation
coefficient (r) indicates the strength and direction of a linear relationship between two
random variables. The first two random variables are Blaine fineness and PSD, shown in
Figure 4.4(a). The second two random variables are percentage passing 45 µm sieve and
PSD, shown in Figure 4.4(b). The Blaine fineness value is strongly correlated to the
particle size distribution below 10 µm, particularly 3 µm. Therefore, it can be concluded
that the CKDs generally have more fine particles (<10 µm) than PCs. Since the Blaine
fineness does not correlate well to the particles above 10 µm (r < 0.7), the Blaine fineness
indicates very little about the material PSD overall. The percentage of material passing
the 45 µm sieve has a good correlation (r > 0.7) to the particle size from approximately
10 µm to approximately 100 µm. Therefore, the Blaine fineness is representative of the <
10 µm portion of the PSD and the percentage passing 45 µm sieve is representative of the
> 10 µm portion of the PSD.
155
Figure 4.2 Particle size distribution of PC, CKD and filler. The materials are in the
direction and position of the arrow: LS, D, SLX, TII, TI, A, F, C, E, B, D*
Figure 4.3 Particle size distribution of PC, CKD and filler between 0.1 µm and 10 µm.
The materials are in the direction of the arrow: LS, SLX, C, D, B, A, F, TII, TI, E, D*
156
(a)
(b)
Figure 4.4 CKD fineness correlation between (a) Blaine fineness and particle size
distribution, and (b) percentage passing 45µm sieve and particle size distribution
R elations hip between B laine and
P S D for C K D s
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.1 1 10 100 1000
P a rtic le siz e (µm)
Co
rre
lati
on
Co
eff
icie
nt
(r)
R elations hip between P erc entag e P as s ing 45 µm
S ieve and P S D for C K D s
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.1 1 10 100 1000
P a rtic le siz e (µm )
Co
rre
lati
on
Co
eff
icie
nt
(r)
157
Statements/Observations:
4.ix There are two ways to modify the current PC analysis methods for accurate
Blaine fineness and PSD CKD analyses:
i. The relative density of the CKD should be used in determining the Blaine
fineness value, as opposed to the relative density of PC (3.15), which is
used to determine the Blaine fineness of PCs according to ASTM C114,
and
ii. The PSD of CKDs should include ultrasound treatment to ensure
agglomeration of fine particles does not occur.
4.x CKDs generally have higher Blaine values than PCs. The Blaine fineness test
correlates well with the particle size distribution below 10 µm (r > 0.7),
particularly 3 µm.
4.xi CKDs have a lower percentage of material passing a 45 µm sieve in
comparison to PCs. The CKD percentage of material passing the 45 µm sieve
has a good correlation (r > 0.7) to the CKD particle size from approximately
10 µm to 100 µm.
4.xii CKDs have lower relative density (2.65 – 2.97) than that of Cement TI (3.11)
and Cement TII (3.18).
4.xiii The CKD mean particle sizes (D50) had a range between 9.71 – 22.58 µm.
Cement TI (15.51 µm) and Cement TII (14.37 µm) were within this range.
158
4.1.4 CKD Dissolution Analysis
The dissolution of ionic species in water and composition of the liquid phase play an
important role in PC hydration. The principal ions dissolved in solution are K+, Na+,
Ca2+, SO42-, and OH-. Silicate and aluminate species dissolve to a much lesser extent.
There is a charge balance between the cations and anions in solution. The ion
contributions from CKDs may influence the charge balance and ultimately the solubility
behaviour of phases during the early stages of PC hydration. The liquid phase
composition of a high-alkali PC paste (w/b of 0.5) during hydration over a period of three
months is shown in Figure 4.5.
Figure 4.5 Composition of pore solution w/b 0.5 high alkali PC paste (Gartner et al.,
2002)
159
Rapid ion dissolution at high water/solid ratios gives an indication of the relative
differences between PCs and CKDs. In order to gain appreciation for the ion
contributions from CKDs relative to PC, the liquid filtrate ion compositions of CKDs and
Cements TI and TII at 10:1 water to solid ratio (by mass) in solution after 10 minutes of
mixing were conducted; results are shown in Table 4.7. The total ion contribution from
the CKDs ranges from 3779 to 6735 mg/L, which is significantly higher than the total ion
contributions from Cement TI (1717 mg/L) and Cement TII (1750 mg/L).
Table 4.7 Ionic concentrations of 10:1 water to solid ratio (by mass)
solution analysis @ 10 minutes (concentration mg/L)
TI TII CKD A
CKD B
CKD C
CKD D*
CKD D
CKD E
CKD F
Calcium 731 1095 1338 1426 1570 2368 1789 1873 1730 Chloride 0.00 0.00 1003 1402 497 151 301 2150 832
Potassium 782 517 1730 2260 1502 1550 1910 2464 1639 Sodium 104 38 234 197 62 111 213 97 68
Sulfur 63 48 29 122 73 139 120 71 98
Silica 6.39 3.03 1.32 2.11 3.35 1.25 2.80 1.43 1.35 Alumina 0.57 0.67 0.74 1.50 2.37 0.77 1.81 0.97 0.82
Iron 0.34 0.48 0.48 0.88 1.29 0.29 0.68 0.35 0.23 Magnesium 0.27 0.58 0.41 0.72 1.62 0.38 0.63 0.39 0.69
Hydroxyl Ions 29 47 61 62 66 83 77 77 75
Total Ions 1717 1750 4398 5474 3779 4405 4416 6735 4445
pH* 12.5 12.7 12.8 12.8 12.8 12.9 12.9 12.9 12.9
CKD LEGEND
Bold: Greater than in both PCs
Italics: Greater than in one of the PCs
Regular: Less than or equal to both PCs * pH was calculated using hydroxyl ion concentration in the formula’s; pOH = - log ( OH-) & pH = 14- pOH
160
Calcium, chloride, potassium, alumina, and hydroxyl ions were all significantly higher in
the liquid filtrate of the CKDs in comparison to the concentrations found in the liquid
filtrate of Cements TI and TII. The pH of the CKD liquid filtrates was also higher than
that of the control cements. Sulfur ions were higher in the liquid filtrate of the CKDs than
that of Cements TI and TII, with the exception of CKD A. This is not surprising since the
sulfur content of CKD A was also determined to be lower than that of Cements TI and
TII. Sodium, iron, and magnesium ion contribution levels from CKDs varied in
comparison to the control cements. Silica ion levels of the liquid filtrates for the CKDs
were all lower than the silica ion levels found in the PC liquid filtrates. The lower silica
ion contributions from CKDs are likely due to the lower levels of alite and belite, in
comparison to PCs.
The dilute stirred suspension test results show that the ions available from CKDs during
early stages of hydration will likely be qualitatively the same as the ions available from
PCs, with the exception of chloride ions. Chloride ions, however, are commonly used as
accelerators in concrete mixtures. It is likely that CKD-PC blends will have significantly
higher amounts of ions entering solution during the early stages of hydration, in
comparison to PC alone. The elevated amount of alumina ions in the CKD liquid filtrates
is somewhat surprising since the chemical composition analyses show that most of the
CKDs have lower alumina oxide contents than that found in the PCs. This is an indication
that the alumina in CKDs may be more readily soluble than the alumina in PCs.
161
Statements/Observations:
4.xiv The ion contributions from CKDs are qualitatively the same as the ion
contributions from PC, with the exception of chloride ions.
4.xv Calcium, chloride, potassium, alumina, and hydroxyl ions were all higher in
the CKD liquid filtrates in comparison to the concentrations found in the PC
liquid filtrates at 10 minutes. Although the effects of these ions are not
uniform, these ions can significantly impact the early stages of hydration.
4.xvi The total ion contribution in liquid filtrate of dilute stirred suspensions is
higher from CKDs than PCs at 10 minutes.
4.xvii The pH of the CKD liquid filtrates is higher than that of the PC liquid filtrates
at 10 minutes.
162
4.2 CKD-PC Blends
The second objective of this research program was to develop an improved understanding
of the effects of utilizing CKDs as partial replacements of PC. Although the single effect
of any one of the common components found in CKDs can be stated in general terms,
specific reactions among the multiple components within CKDs are difficult to
contemplate. Since CKDs contain multiple components that affect the properties of
blends, it is difficult to separate the effects of the individual components. Further, the
influence of the same CKD at equal replacement levels of two different PCs can
influence the hydration differently. Therefore, regression analysis was applied where
possible to deduce the relationships between CKD-PC binder properties and various
independent variables.
The combined compositions for the CKD-PC blends were calculated based upon
percentage composition, by mass. All paste and mortar blends were made with 10% and
20% of CKD or filler replacements by total mass of each of Cements TI and TII. The
calculated chemical, physical, and mineralogical properties of these blends are shown in
Appendix D. Overall, 34 different mixtures were prepared using 0% (control), 10%, and
20% of the seven CKDs and two filler replacements by total mass of Cements TI and TII.
As an indication of the composition differences of CKD-PC and PC-filler blends in
comparison to PC alone, the range for the chemical and select physical properties of
CKD and fillers at 10% and 20% replacement of Cements TI and TII are shown in Tables
4.8 (Cement TI blends) and 4.9 (Cement TII blends). The CKD-PC blend chemical and
physical properties that are significantly different from PC alone are in bold and
highlighted.
163
Table 4.8 Range for chemical and physical properties of Cement TI blends at 10% and
20% replacement (Theoretical calculation, mass %)
Components TI CKDs at 10%
TI replacement CKDs at 20%
TI replacement Fillers at 10% TI replacement
Fillers at 20% TI replacement
Min. Max. Min. Max. Min. Max. Min. Max.
SiO2 19.15 18.66 19.65 18.17 20.14 17.50 27.05 15.84 34.95
Al2O3 5.83 5.62 6.16 5.42 6.49 5.29 5.32 4.76 4.80
Fe2O3 2.46 2.37 2.59 2.28 2.72 2.22 2.23 1.98 2.01
CaO 62.03 59.10 61.41 56.16 60.80 55.83 61.18 49.63 60.32
MgO 2.18 2.07 2.27 1.95 2.36 1.96 2.02 1.75 1.86
SO3 4.35 4.22 5.53 4.09 6.71 3.92 3.92 3.49 3.49
Na2O 0.30 0.29 0.34 0.28 0.37 0.27 0.27 0.24 0.24
K2O 1.01 1.23 1.39 1.45 1.78 0.92 0.93 0.83 0.85
Na2Oe 0.97 1.10 1.24 1.23 1.51 0.88 0.89 0.79 0.80
Sol. Na2O 0.16 0.15 0.18 0.15 0.21 0.14 0.14 0.13 0.13
Sol. K2O 0.97 1.07 1.26 1.17 1.56 0.87 0.87 0.77 0.77
Sol. Na2Oe 0.80 0.86 1.00 0.92 1.21 0.72 0.72 0.64 0.64
TiO2 0.25 0.24 0.28 0.24 0.31 0.23 0.23 0.21 0.21
P2O5 0.26 0.24 0.25 0.21 0.24 0.23 0.23 0.21 0.21
Mn2O3 0.09 0.08 0.13 0.08 0.17 0.08 0.08 0.07 0.07
Cl 0.00 0.03 0.25 0.07 0.50 0.00 0.00 0.00 0.00
Ca(OH)2 0.40 0.36 0.85 0.32 1.30 0.36 0.36 0.32 0.32
fCaO 0.40 0.76 3.81 1.13 7.22 0.36 0.36 0.32 0.32
LOI 1.79 2.15 4.48 2.52 7.18 1.63 5.84 1.47 9.89
pH* 11.9 11.92 11.99 11.94 12.09 11.31 11.66 10.72 11.42
Relative Density 3.11 3.07 3.10 3.02 3.08 3.07 3.07 3.02 3.03
Blaine (m2/kg) 367 365 399 364 430 379 394 391 421
45µm, % passing 95.7 92.5 94.9 89.2 94.0 96.0 96.1 96.2 96.5 Na2Oe: Na2O + 0.658 (K2O) fCaO: free lime LOI: Loss on ignition * based on w/b = 10 solution analysis @ 10 minutes
164
Table 4.9 Range for chemical and physical properties of Cement TII blends at 10% and
20% replacement (Theoretical calculation, mass %)
CKDs at 10% CKDs at 20% Fillers at 10% Fillers at 20%
Components TII TII replacement TII replacement TII replacement TII replacement
Min. Max Min. Max Min. Max Min. Max
SiO2 20.39 19.77 20.75 19.16 21.12 18.61 28.16 16.83 35.94
Al2O3 4.21 4.16 4.70 4.12 5.19 3.83 3.85 3.46 3.50
Fe2O3 3.01 2.86 3.08 2.72 3.16 2.71 2.73 2.42 2.45
CaO 63.06 60.02 62.34 56.99 61.62 56.75 62.10 50.45 61.14
MgO 3.21 2.99 3.20 2.77 3.19 2.89 2.95 2.57 2.68
SO3 2.98 2.98 4.30 2.99 5.61 2.68 2.68 2.39 2.39
Na2O 0.13 0.14 0.18 0.14 0.24 0.12 0.12 0.11 0.11
K2O 0.69 0.94 1.10 1.19 1.51 0.62 0.64 0.56 0.59
Na2Oe 0.58 0.75 0.89 0.92 1.20 0.53 0.54 0.48 0.50
Sol. Na2O 0.06 0.07 0.10 0.07 0.13 0.06 0.06 0.05 0.05
Sol. K2O 0.64 0.78 0.97 0.91 1.30 0.58 0.58 0.51 0.51
Sol. Na2Oe 0.49 0.58 0.72 0.67 0.96 0.44 0.44 0.39 0.39
TiO2 0.26 0.25 0.29 0.25 0.32 0.24 0.24 0.21 0.21
P2O5 0.12 0.11 0.12 0.10 0.13 0.11 0.11 0.10 0.10
Mn2O3 0.56 0.51 0.55 0.46 0.55 0.50 0.50 0.45 0.45
Cl 0.00 0.03 0.25 0.07 0.50 0.00 0.00 0.00 0.00
Ca(OH)2 1.30 1.17 1.66 1.04 2.02 1.17 1.17 1.04 1.04
fCaO 0.55 0.90 3.94 1.24 7.34 0.49 0.49 0.44 0.44
LOI 1.28 1.70 4.02 2.12 6.77 1.17 5.38 1.06 9.48
pH* 11.9 11.92 11.99 11.94 12.09 11.31 11.66 10.72 11.42
Relative Density 3.18 3.13 3.16 3.07 3.14 3.13 3.13 3.08 3.09
Blaine (m2/kg) 377 374 408 372 438 388 403 399 429
45µm, % passing 92.0 89.1 91.5 86.2 91.1 92.6 92.8 93.2 93.5 Na2Oe: Na2O + 0.658 (K2O) fCaO: free lime LOI: Loss on ignition * based on w/b = 10 solution analysis @ 10 minutes
165
An assessment of the CKD-PC blend compositions in comparison to the control PC alone
and control PC-filler blends provides insight into the potential influence of partial CKD
replacements of PC. The presence of CKDs causes the sulfate, alumina, alkalis,
portlandite, free lime, and chloride contents of the CKD-PC blends to generally be the
same or higher than that of the control PC alone and of control PC-filler blends. The
magnitude of the change for each component is important to consider in assessing the
potential impact of each component’s elevated concentration. The physical properties of
the CKD-PC blends are also important factors to consider.
PC performance is highly sensitive to small changes in sulfate content which can result in
very significant effects on hydration, strength development, and volume stability. The
sulfate contents of the CKD-PC blends change relative to the control mixes within a
range of -0.13% to +0.98% for the blends with Cement TI and 0.0% to 1.32% for the
blends with Cement TII. In relation to the sulfate content, the elevated alumina
concentrations could affect the optimum sulfate/alumina balance required for normal set
to occur. The factor most influencing the effect of calcium sulfate on the early reactions
is the rate at which the calcium and sulfate ions are made available in solution. Elevated
calcium concentrations during early stages of hydration due to increased free lime and
portlandite may allow the excess sulfates to combine with calcium to behave similarly to
calcium sulfate (gypsum).
Alkalis are widely reported to accelerate alite hydration, but this is only when the sulfate
levels were optimized. At sulfate levels above optimum, the acceleration effects of alkalis
were either reduced or suppressed. The presence of higher calcium, as well as alkali
concentrations, during early stages of hydration may also influence the solubility of
phases during early age hydration. Increased hydroxyl ions, as a result of portlandite and
alkalis, may also increase the potential for ASR.
166
With respect to chlorides, calcium chloride is the most effective for accelerating
hydration of C3S (Taylor, 1997). Bhatty (1984) suggested that CKD alkali chlorides
would behave similarly to calcium chloride. Chlorides are known to accelerate PC
hydration and dosages between 1 and 2% of PC content (by mass) are generally
recommended in the field for non-reinforced concrete. The maximum chloride
concentration within the CKD-PC blends, however, is only 0.50%. Therefore, optimal
acceleration of alite hydration would not be expected. The presence of chlorides could be
a concern for steel reinforcement corrosion in concrete. In EN-197, chloride contents of
cements are limited to 0.10%.
Additional free lime and calcium hydroxide has an important role to play in the initial
hydration of PC by supplying calcium ions to the system. Any change in the lime
concentration or displacement of the solubility equilibrium of portlandite – such as
addition of calcium salts or alkalis – may change the formation characteristics of C-S-H.
Soft burnt (highly reactive) free lime may increase water demand. Hard burnt free lime
raises a concern for soundness due to its delayed hydration.
The relative densities of the CKD-PC blends are similar to those of the control PC-filler
blends but lower than that of the control PC alone. An increase in the volume of solid
particles may impact rheological properties. The CKD-PC blends generally have higher
Blaine fineness values but lower percentage passing 45 µm. This implies that the CKDs
have a broader particle size range than PCs, with CKDs having higher amounts of both
very fine and coarse particles than PCs. The CKD-PC blends generally have similar
Blaine fineness values but lower percentage passing 45 µm in comparison to that of the
PC-filler blends. The fineness of the CKD-PC blends can broadly influence chemical
reactivity, rheological properties, volume stability, and durability.
167
4.2.1 Kinetics
4.2.1.1 Heat of Hydration
The rate of heat liberation on the recorded output is used as a means of measuring the rate
of hydration. Isothermal conduction calorimetry was used to assess the heat evolution of
pastes at 0%, 10%, and 20% replacement of Cements TI and TII, in accordance with
ASTM C1679. Six CKDs from different cement plants, a limestone powder, and a quartz
powder were used as the replacement materials. Each sample was performed at a w/b
ratio of 0.40 in duplicate to check the repeatability of the heat of hydration tests. The total
heat measurements of the duplicate tests were within ±3% of each other. The rates of heat
evolution during initial hydrolysis did vary somewhat but after the transition to the
induction period, the rates of heat evolution were essentially the same.
In order to create regression models for the influence of composition and fineness on
CKD-PC blends, a characterization system was developed for the heat liberation curves
as shown in Figure 4.6. The parameters of the heat curve that were used to characterize
the behaviour of hydration are: the total heat evolved during initial hydrolysis (Ai), the
minimum rate of heat evolution during the induction period (Qi), the time at which Qi
occurs (ti), the maximum rate of heat evolution (Qw), the rate of heat evolution between
the minimum rate of heat evolution during the induction period and the maximum rate of
heat evolution (Qw-Qi), and the cumulative heat evolution after initial hydrolysis over
seven days (A7d-Ai) (the cumulative heat evolution is simply the area under the rate
curve for the time under consideration).
168
Figure 4.6 Schematic of isothermal conduction calorimetry curve heat liberation
characterization
The rate of heat development curves for various time periods over seven days of
hydration are shown in Appendix E. The heat liberation curves indicate that the presence
of different CKDs is markedly different from the control PC alone and equivalent
amounts of limestone or silica flour as partial replacements of PC. The magnitude of the
peaks and the times at which they occur depends on the chemical, mineralogical, and/or
physical properties of each binder blend.
Sulfate Depletion Peak
A7d-Ai
169
The heat liberation curve of PC consists of a large initial peak represented by Ai. The Ai
for each control, CKD-PC blend, and PC-filler blend is presented in Figure 4.7. In
agreement with results reported by Wang et al. (2002), the CKD-PC blends had similar or
higher heat evolution during initial hydrolysis than the respective control cements. Based
upon Ai, it appears there is a similar or higher chemical reactivity during the initial
hydrolysis period in the CKD-PC blends than the respective cement alone controls. The
CKD-PC blends initial hydrolysis heat evolutions were similar to or higher than the PC-
filler blends at equivalent replacement levels. As the percentage of CKD replacement
increased from 10% to 20%, the total heat evolution remained similar or increased. The
blends with CKDs from preheater/precalciner processes, CKDs E and F, had the highest
heat evolution during initial hydrolysis in comparison to the respective PC control and all
blends with equivalent replacement of PC.
The main contributing factors that are reported to affect initial hydrolysis heat evolution
are (i) hydration of free lime, (ii) hydration of calcium sulfate hemihydrate to gypsum,
and (iii) formation of AFt, primarily from the aluminate phase but also from the ferrite
phase (Bensted, 1987). Since the initial dissolution of ions from CKDs are qualitatively
the same as from PCs, as shown in Section 4.1.4, the same factors that affect initial
hydrolysis of heat evolution for PCs are likely the same as those for CKD-PC blends.
Further, the mineralogical components of PCs that are known to affect initial hydrolysis
are the same as those found in CKDs.
The heat evolution Ai as a function of free lime content of the binder is shown for the two
control cements and CKD-PC blends in Figure 4.8. It appears the relationship for Ai is
linear with a positive slope for the binders as a function of free lime concentration greater
than 2% for both Cements TI and TII CKD blends. Scatter in the data for mixtures with
less than 2% free lime, however, indicates that factors other than free lime are also
involved.
170
(a)
0
5
10
15
10% replac ement 20% replac ement
Init
ial
Hy
dro
lys
is
(Ai)
He
at
Ev
olu
tio
n,
J/g
TII
TII L S
TII S L X
TII C K D A
TII C K D B
TII C K D C
TII C K D D
TII C K D E
TII C K D F
(b)
Figure 4.7 Cumulative heat of hydration during initial hydrolysis (Ai) of (a) Cement TI
blends and (b) Cement TII blends (w/b = 0.4, 23°C)
(The legends are ordered top (left) to bottom (right) for the bar charts)
0
5
10
15
10% replac ement 20% replac ement
Init
ial
Hy
dro
lys
is
(Ai)
He
at
Ev
olu
tio
n,
J/g
TI
TI L S
TI S L X
TI C K D A
TI C K D B
TI C K D C
TI C K D D
TI C K D E
TI C K D F
A B C
D
E
F
A
B
C
D
E
F
A B
C D
E
F
A B
C
D
E
F
TI
SLX LS
TI SLX LS
TII SLX
LS
TII
SLX LS
171
2.5
5
7.5
10
12.5
15
Ai, (
mW
/g.h
)
0 2 4 6 8
Free CaO, %
(a)
4
6
8
10
12
Ai, m
W/g
.h
0 2 4 6 8
Free CaO, %
(b)
Figure 4.8 Cumulative heat of hydration during initial hydrolysis (Ai) as a function of
Free CaO (%) for (a) Cement TI CKD blends and (b) Cement TII CKD blends (w/b =
0.4, 23°C)
10%
20%
Control
PC Replacement
r = 0.987
r = 0.956
10%
20%
Control
PC Replacement
172
In order to determine the influence of CKD-PC blends with less than 2% free lime
content, all blends with CKDs E and F were removed from the regression analysis. For
Cement TI blends, the initial heat evolution as a function of sulfate content of the binder
was linear with a positive slope, as shown in Figure 4.9(a). One possible reason for this is
that the increased quantity of sulfate ions from CKDs could lead to increased chemical
reaction with the Cement TI aluminate phase to form more AFt.
The Cement TII-CKD blend initial hydrolysis heat evolution as a function of the binder
alkali concentration was linear with a positive slope, as shown in Figure 4.9(b). The high
rate of dissolution of alkalis from the CKD fraction would likely increase the pH of the
liquid phase during initial hydrolysis. Dyer et al. (1999) suggested that the higher pH
levels produced by alkalis dissolving into solution from CKDs would likely promote
formation of more hydrates and lead to higher heat evolution during early age hydration.
173
4
5
6
7
8
Ai, J
/g
4 4.5 5 5.5 6 6.5 7
Sulfate, %
(a)
4
4.5
5
5.5
6
6.5
7
Ai (J
/g)
.4 .6 .8 1 1.2 1.4
Total Alkalis (NaEq), %
(b)
Figure 4.9 Cumulative heat of hydration during initial hydrolysis (Ai) as a function of (a)
sulfate content for Cement TI CKD blends and (b) alkali content for Cement TII CKD
blends (w/b = 0.4, 23°C)
r = 0.880
10%
20%
Control
PC Replacement
r = 0.866
10%
20%
Control
PC Replacement
174
The induction period, which follows the initial hydrolysis phase, is characterized by a
period of very little heat evolution. The minimum rate of heat evolution during the
induction period (Qi) of Cements TI and TII CKD blends is shown in Figure 4.10. The Qi
for Cement TI CKD blends were similar to or higher than that of the Cement TI control.
The Qi for Cement TII CKD blends, however, were both above and below that of the
Cement TII control. It appears the relationship for Qi is linear with a positive slope for
the binders as a function of sulfate concentration for both Cements TI and TII CKD
blends, as shown in Figure 4.11.
During the induction stage, the influence of increased sulfate concentration on the rate of
heat evolution is likely due to increased formation of AFt. The Cement TI CKD blends
have a higher correlation to the sulfate content than the Cement TII CKD blends. C3A
reacts with calcium and sulfate ions to form AFt. Since Cement TI has a higher C3A
content than Cement TII, this further indicates the likelihood of AFt formation as a
governing factor. The sulfate form of the CKD-PC binder influence on Qi is also
important. Figure 4.12 shows that Qi is also linear with a positive slope as a function of
calcium langbeinite for both Cement TI and TII blends.
175
0.0
0.5
1.0
1.5
2.0
10% replac ement 20% replac ement
Qi,
mW
/g
TI
TI L S
TI S L X
TI C K D A
TI C K D B
TI C K D C
TI C K D D
TI C K D E
TI C K D F
(a)
0.0
0.5
1.0
1.5
2.0
10% replac ement 20% replac ement
Qi,
mW
/g
TII
TII L S
TII S L X
TII C K D A
TII C K D B
TII C K D C
TII C K D D
TII C K D E
TII C K D F
(b)
Figure 4.10 Minimum heat of hydration rate during induction period (Qi) of (a) Cement
TI blends and (b) Cement TII blends (w/b = 0.4, 23°C)
(The legends are ordered top (left) to bottom (right) for the bar charts)
A
B
C
D
E
F
A
B
C
D
E
F
A B
C
D E F
A B
C
D
E
F
TI SLX
LS TI SLX
LS
TII
SLX LS
TII
SLX LS
176
0.5
0.75
1
1.25
1.5
Qi, m
W/g
4 4.5 5 5.5 6 6.5 7
Sulfate, %
(a)
0.5
0.75
1
1.25
1.5
1.75
Qi, m
W/g
2.5 3 3.5 4 4.5 5 5.5 6
Sulfate, %
(b)
Figure 4.11 Minimum heat of hydration rate during induction period (Qi) as a function of
sulfate content for (a) Cement TI CKD blends and (b) Cement TII CKD blends (w/b =
0.4, 23°C)
r = 0.921
10%
20%
Control
PC Replacement
r = 0.765
10%
20%
Control
PC Replacement
177
0.5
0.75
1
1.25
1.5
1.75
Qi, m
W/g
0 .1 .2 .3 .4 .5 .6
Calcium Langbeinite, %
(a)
0.5
0.75
1
1.25
1.5
1.75
Qi, m
W/g
0 .1 .2 .3 .4 .5 .6
Calcium Langbeinite, %
(b)
Figure 4.12 Minimum heat of hydration rate during induction period (Qi) as a function of
calcium langbeinite content for (a) Cement TI CKD blends and (b) Cement TII CKD
blends (w/b = 0.4, 23°C)
r = 0.908
10%
20%
Control
PC Replacement
r = 0.873
10%
20%
Control
PC Replacement
178
The time of the minimum rate heat evolution during the induction period (ti) for all
control blends is shown in Figure 4.13. The ti for CKD-PC blends occurred later than that
of the pastes with PCs alone and/or PC-filler blends. These findings were in agreement
with the results reported by Wang et al. (2002) using a CKD at 0, 15%, and 25%
replacement of an OPC. The relationship for ti is linear with a positive slope for the
binders as a function of total alkali concentration for both Cement TI and Cement TII
CKD blends, as shown in Figure 4.14.
Although there are many hypotheses regarding the mechanics of the induction phase,
many researchers advance that it is caused by formation of a protective layer on the C3S
particles inhibiting further hydration and terminates when this layer is destroyed or
rendered more permeable by aging or phase transformation (Gartner et al., 2002). It is
widely reported that alkalis accelerate hydration of C3S. It is important to note that this
effect, however, is only found in PCs with optimized sulfate content levels. The increased
alkali content of the CKD-PC blends, which were not optimized for sulfate content,
appeared to delay Qi. This indicates that CKD alkali content retarded the normal
hydration of C3S. One suggestion that could explain the correlation between the increased
alkali concentration and the delayed time of Qi (ti) is reduced solubility of C3S due to the
common ion effect (Gartner et al., 2002).
179
0.0
0.5
1.0
1.5
2.0
2.5
10% replac ement 20% replac ement
ti,
ho
urs
TI
TI L S
TI S L X
TI C K D A
TI C K D B
TI C K D C
TI C K D D
TI C K D E
TI C K D F
(a)
0.0
0.5
1.0
1.5
2.0
2.5
10% replac ement 20% replac ement
ti,
ho
urs
TII
TII L S
TII S L X
TII C K D A
TII C K D B
TII C K D C
TII C K D D
TII C K D E
TII C K D F
(b)
Figure 4.13 Time of minimum heat of hydration rate during the induction period (ti) of
(a) Cement TI blends and (b) Cement TII blends (w/b = 0.4, 23°C)
(The legends are ordered top (left) to bottom (right) for the bar charts)
A
B
C D
E F A
B
C
D
E F
A
B
C
D
E
F
A
B C
D
E F
TI
SLX LS
TI
SLX
LS
TII SLX LS
TII SLX LS
180
1.25
1.5
1.75
2
2.25
2.5
ti, hours
.9 1 1.1 1.2 1.3 1.4 1.5 1.6
Total Alkalis (NaEq), %
(a)
1
1.25
1.5
1.75
ti, hours
.4 .6 .8 1 1.2 1.4
Total Alkalis (NaEq), %
(b)
Figure 4.14 Time of minimum heat of hydration rate during the induction period (ti) as a
function of total alkali content for (a) Cement TI CKD blends and (b) Cement TII CKD
blends (w/b = 0.4, 23°C)
r = 0.762
10%
20%
Control
PC Replacement
r = 0.825
10%
20%
Control
PC Replacement
181
Following the induction phase, an ascending rate of heat generation leads to the main
hydration peak. The ascending curve and the main hydration peak correspond to
hydration of the C3S. The CKDs generally do not possess high amounts of C3S that could
contribute to the main hydration peak. Any pozzolanic reaction that could occur is
typically not observed, if at all, until after the main hydration peak in isothermal
conduction calorimetry. Therefore, the main hydration peak of the CKD-PC blends can
be assumed to be mostly the C3S contribution of the PC. The magnitude of the main
hydration peak (Qw) is typically used to assess C3S hydration between different samples.
Since Qi varied significantly among the CKD-PC blends, the main hydration peak
relative to Qi (Qw-Qi) was used to assess the effects on C3S hydration during the
acceleration stage leading to the main hydration peak.
The Qw-Qi for each mix is shown in Figure 4.15. The Qw-Qi for the CKD-PC blends
varied widely, as many were both above and below the respective PC control. As the
percentage of CKD replacement increased from 10% to 20% for each CKD blend, the
Qw-Qi decreased. This effect was more pronounced in the Cement TI CKD blends than
in the Cement TII CKD blends. Blends with CKDs A, B, and E had the highest Qw-Qi
for both PCs within their respective 10% and 20% replacement categories. These CKDs
generally have higher chloride and lower sulfate contents than CKDs C, D, and F. The
dilution effect of PC appears as a reduction in the Qw-Qi. The magnitudes of the Qw-Qi
for blends with limestone and silica sand as partial replacement of PC were lower than
that of the control PCs alone and all CKD-PC blends with the same respective control
PC.
182
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
10% replac ement 20% replac ement
Qw
- Q
i, m
W/g
TI
TI L S
TI S L X
TI C K D A
TI C K D B
TI C K D C
TI C K D D
TI C K D E
TI C K D F
(a)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
10% replac ement 20% replac ement
Qw
- Q
i, m
W/g
TII
TII L S
TII S L X
TII C K D A
TII C K D B
TII C K D C
TII C K D D
TII C K D E
TII C K D F
(b)
Figure 4.15 Main hydration peak relative to the minimum peak rate heat of hydration
during the induction period (Qw-Qi) for (a) Cement TI blends and (b) Cement TII blends
(w/b = 0.4, 23°C)
(The legends are ordered top (left) to bottom (right) for the bar charts)
A B
C
D
E
F
A B
C
D
E
F
A
B
C D
E
F
A B
C
D
E
F
TI
SLX LS
TI
SLX LS
TII SLX
LS TII SLX
LS
183
The Qw-Qi had a good correlation with the calcium langbeinite content of the CKD-PC
blends, as shown in Figure 4.16. The Qw-Qi has a negative linear slope as a function of
calcium langbeinite content for both Cements TI and TII CKD blends. It is known that
the main hydration peak is generally depressed at gypsum (calcium sulfate) levels above
the optimum sulfate content (Lawrence, 1998b) and that there is significant C-S-H uptake
of sulfate ions. The decrease in Qw-Qi as the calcium langbeinite increased suggests that
the calcium langbeinite may be providing calcium and sulfate ions, similar to gypsum.
184
2
2.5
3
3.5
4
Qw
-Qi, m
W/g
0 .1 .2 .3 .4 .5 .6
Calcium Langbeinite, %
(a)
2
2.5
3
3.5
4
Qw
-Qi, m
W/g
0 .1 .2 .3 .4 .5 .6
Calcium Langbeinite, %
(b)
Figure 4.16 Main hydration peak relative to the minimum peak rate heat of hydration
during the induction period (Qw-Qi) as a function of calcium langbeinite content for (a)
Cement TI CKD blends and (b) Cement TII CKD blends (w/b = 0.4, 23°C)
r = -0.910
10%
20%
Control
PC Replacement
r = -0.786
10%
20%
Control
PC Replacement
185
Although calcium langbeinite seems to have a strong influence on the kinetics of C-S-H
formation, other components appear to also affect C3S hydration if sulfate levels are low.
The increased Qw-Qi for some of the CKD-PC blends is likely due to the presence of
chlorides that caused the main hydrate peak to be higher and narrower. As shown in
Figure 4.17(a), the high-chloride; low-sulfate CKD A at 10% replacement of Cement TI
caused the ascending slope to be steeper and narrower in comparison to LS at 10%
replacement of Cement TI. The low-chloride; medium-sulfate CKD C at 10%
replacement of Cement TI had little impact on the shape of the hydration curve from the
induction phase to the main hydration peak, as shown in Figure 4.17(b). This may be due
to low solubility of the sulfate in CKD C.
The heat of hydration curves for Cement TI at 0% (control) and 20% replacement with
LS are shown in Figure 4.17(c). The dilution effect of limestone is evidenced by a
reduction in the main hydrate peak. CKD B at 20% replacement of Cement TI appeared
to have a significant broadening immediately after the main hydration peak indicating
pozzolanic reactivity, as shown in Figure 4.17(d). This was likely due to the presence of
reactive fly ash in CKD B.
186
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD A 10%
TI LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
) TI CKD C 10%
TI LS 10%
(a) (b)
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI
TI LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD B 20%
TI LS 20%
(c) (d)
Figure 4.17 Heat of hydration for Cement TI with (a) CKD A and LS at 10%
replacements, (b) CKD C and LS at 10% replacements, (c) 0% and LS at 20%
replacements, and (d) CKD B and LS at 20% replacements (w/b = 0.4, 23°C)
187
The sulfate depletion (aluminate hydrate) peak for a properly retarded PC occurs after the
main hydration peak, as shown for Cement TI in Figure 4.18(a). The Cement TII heat
evolution aluminate peak, however, was superimposed on the main silicate hydration
peak, as shown in Figure 4.19(a). This implies that Cement TII does not have sufficient
available gypsum to retard the early hydration of aluminate phase. It appears the presence
of CKD retards or suppresses the time of the sulfate depletion peak for the CKD-PC
blends, as shown in Figure 4.18(b) and Figure 4.19(b, c). Calcium and sulfate ions in the
form of gypsum are known to retard the sulfate depletion peak by forming AFt. This
implies that CKD is contributing excess calcium and sulfate ions that are readily
available to react with C3A. Since calcium langbeinite appears to have a significant
influence on the early age of hydration during the induction phase, it is reasonable to
assume it can also affect the sulfate depletion peak. This is particularly important, since
the proposed mechanism for calcium langbeinite takes into account the rate at which the
sulfate phase can supply both calcium and sulfate ions to the surfaces of the aluminate
phases during early stage hydration (Tang and Gartner, 1988).
188
(a)
(b)
Figure 4.18 Heat of hydration for Cement TI with (a) 0% and LS at 10% replacements
and (b) CKD E and LS at 20% replacements (w/b = 0.4, 23°C)
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI
TI LS 10%Sulfate depletion peak
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD E 20%
TI LS 20%
189
(a)
(b)
(c)
Figure 4.19 Heat of hydration for Cement TII with (a) 0% and LS at 10% replacements,
(b) CKD C and LS at 10% replacements, and (c) CKD C and LS at 20% replacements
(w/b = 0.4, 23°C)
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
hea
t evo
luti
on
(m
W/g
)
TII
TII LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD C 10%
TII LS 10%
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD C 20%
TII LS 20%
Sulfate depletion peak
190
The heat due to initial hydrolysis was subtracted from the total heat evolution (A7d-Ai) in
order to compare effects on C3S hydration. The total heat generation from the induction
period to seven days hydration (A7d-Ai) of all blends is shown in Figure 4.20. At 10%
replacement of PC, the CKD-PC blends A7d-Ai were similar to or lower than that of the
PC alone and PC-filler blends. At 20% replacement of PC, the CKD-PC blends were all
lower than PC alone. The A7d-Ai generally decreased as the amount of CKD and filler
replacements increased from 10% to 20%.
191
70
75
80
85
90
10% replac ement 20% replac ement
A 7
d -
Ai,
J/g
TI
TI L S
TI S L X
TI C K D A
TI C K D B
TI C K D C
TI C K D D
TI C K D E
TI C K D F
(a)
70
75
80
85
90
10% replac ement 20% replac ement
A 7
d -
Ai,
J/g
TII
TII L S
TII S L X
TII C K D A
TII C K D B
TII C K D C
TII C K D D
TII C K D E
TII C K D F
(b)
Figure 4.20 The total heat generation from induction period to 7 days hydration (A7d-Ai)
for (a) Cement TI blends and (b) Cement TII blends (w/b = 0.4, 23°C)
(The legends are ordered top (left) to bottom (right) for the bar charts)
A
B C
D
E F
A B
C
D
E F
A
B
C D
E
F
A
B C
D
E
F
TI
SLX
LS TI SLX
LS
TII SLX
LS
TII
SLX
LS
192
Statements/Observations:
4.xviii Cumulative heat generation during initial hydrolysis (Ai) increased between
6% and 120% (more than double) at 10% CKD replacement of PC in
comparison to the respective PC control. At 20% CKD replacement, the Ai
increased between 16% and 208% (more than triple).
4.xix Large and highly reactive amounts of free lime (> 20%), typically found in
CKDs from preheater/precalciner pyroprocesses, readily react with water;
this results in an exothermic reaction that contributes to higher heat
generation during initial hydrolysis in comparison to all other blends and
control cements.
4.xx For Cement TI (high C3A), reactivity with CKD sulfates appears to
contribute to higher heat generation during initial hydrolysis. This reaction
is likely to form AFt. For Cement TII (low C3A), the contribution of alkalis
from CKDs appears to increase heat generation during initial hydrolysis.
4.xxi For Cement TI CKD blends, the minimum rate of heat evolution during the
induction period (Qi) as a function of the binder sulfate content appears to
be a linear relationship with a positive slope. At 10% and 20% replacement
of Cement TI with CKD A, the Qi values were similar (±3%) to that of
Cement TI alone. At 10% and 20% replacement of Cement TI with CKD B,
the Qi values decreased by 5% and 10%, respectively, in comparison to
Cement TI alone. At 10% and 20% replacement of Cement TI with CKDs
C, D, E, and F, the Qi values increased in the range of 25% to 44% and 37%
to 104%, respectively. The increased heat evolution is likely due to the
formation of additional AFt in the Cement TI CKD blends.
193
4.xxii In contrast to Cement TI CKD blends, the Cement TII CKD blends Qi do
not have as strong a relationship with the sulfate content, which is likely due
to the lower C3A level in Cement TII that inhibits the formation of AFt. At
10% and 20% replacement of Cement TII with CKDs A and B, the Qi
values were lower (15-36%) than that of Cement TI alone. At 10%
replacement of Cement TII with CKD C, the Qi value decreased by 8% but
at 20% replacement increased by 36% in comparison to Cement TII alone.
At 10% and 20% replacement of Cement TII with CKDs D, E, and F, the Qi
values increased in the range of 15% to 47% and 28% to 81%, respectively.
4.xxiii The Qi as a function of calcium langbeinite content of the binder appears to
be a linear relationship with a positive slope. This may indicate that the
sulfate form of CKDs contributing to AFt formation during the induction
period is largely due to calcium langbeinite.
4.xxiv The time of the minimum rate of heat during the induction period (ti) for
CKD-PC blends occurred later than that of the pastes with PCs alone. At
10% and 20% CKD replacement of Cement TI and Cement TII, the ti
increased by 13-58% and 29-85%, respectively. In contrast to the CKD-PC
blends, the PC-filler blends ti ranged between -5% and +18% in comparison
to the PC alone.
4.xxv The time of the minimum rate of heat during the induction period (ti) as a
function of the binder alkali content appears to be a linear relationship with
a positive slope. This indicates that CKD alkali content retards the normal
hydration of C3S.
194
4.xxvi The main hydration peak relative to the minimum rate of hydration during
the induction period as a function of the calcium langbeinite content is a
linear relationship with a negative slope. This indicates that the calcium
langbeinite content from CKD inhibits the hydration of C3S.
4.xxvii The sulfate depletion peak that occurs as a result of conversion of AFt to
AFm formation is delayed or suppressed by partial replacement of CKDs for
both PCs with all CKDs, except CKD A. The delay or suppression of AFt to
AFm appears to be due to the increased availability of calcium and sulfate
ions, which simulates the addition of gypsum to the blends.
4.xxviii At 10% replacement of Cement TI and TII with CKD, heat evolutions over
a seven-day period are similar (±5%) or lower (<8%) than the respective PC
control. At 20% replacement of Cement TI and TII with CKD, heat
evolutions decreased between 4% and 14% in comparison to the respective
control PC.
195
4.2.2 Physical Properties of Hydration
4.2.2.1 Normal Consistency
The purpose of the normal consistency test (ASTM C187) was to assess whether CKDs
varied the water demand of the CKD-PC blend pastes. Normal consistency is the water to
binder ratio required to bring the paste to a standard condition of wetness for which the
penetration of a standard needle (Vicat needle) into the paste is 10 ± 1 mm at 30 seconds.
To provide an indication of the sensitivity of the test, the results of the iterative process to
determine the water requirement for normal consistency of Cements TI and TII are
presented in Table 4.10. These results show that as little difference as 0.2% in the normal
consistency water demand can result in a paste that is outside the required range of 10mm
± 1 penetration at 30 seconds.
Table 4.10 Iterative process to determine the water requirement for normal consistency of
(a) Cement TI and (b) Cement TII
(a)
Cement w/b ratio (%) Needle Penetration
(mm)
TI 26.5 12
TI 26.2 8.5
TI 26.4 10
(b)
Cement w/b ratio (%) Needle Penetration
(mm)
TII 24.6 14.5
TII 23.7 6.5
TII 24.1 14
TII 23.8 8
TII 24.0 10
196
The normal consistency water demand results for the PC alone, CKD-PC blends, and PC-
filler blends are shown in Figure 4.21. At 10% replacement of Cements TI and TII, all of
the CKD-PC blends required more water to maintain a normal consistency penetration in
the range of 9 and 11 mm than the respective PC alone. At 20% replacement, each CKD-
PC blend required more water than each 10% replacement blend. Some CKD blends at
20% replacement required less water than CKD blends at 10% replacement with
equivalent PC. The blends with CKDs from preheater/precalciner processes – CKDs E
and F – had the highest water requirement for normal consistency in comparison to the
respective PC control and blends with equivalent replacement of PC. Previous
researchers (El Aleem et al., 2005; Ramakrishnan, 1990; Bhatty, 1984 and 1985a), who
also used normal consistency to study effects of CKD replacement at 10% and/or 20%,
had similar results.
Table 4.11 provides the range for increased water demand of blends with CKDs and
fillers in comparison to the PCs at equivalent replacement levels. At 10% and 20%
replacement of Cements TI and TII, the water requirement increase ranged between 0.1
and 0.7% for SLX and LS. At 10% replacement of Cement TI CKDs A, B, C, and D, the
increase in water demand (0.4 – 0.8%) was similar to or higher than the fillers effect on
the increase in water demand (0.1 – 0.4%). All other CKDs required more water than that
of the fillers as equivalent partial replacements of the same PC.
The blends with CKDs from the preheater/precalciner cement processes were separated
from the remaining CKD blends, since the impact was markedly different. For example,
Cement TI required 26.4% water to maintain normal consistency. At 10% replacement of
Cement TI, the water requirement increase ranged between 0.4 and 0.8% for CKDs A, B,
C, and D. CKDs E and F, however, resulted in an increase between 1.3 and 2.1%. The
water demand impact of CKD replacements was larger in magnitude in the Cement TII
blends than Cement TI blends. This suggests that the magnitude of impact is dependent
upon the composition of both the CKD and PC.
197
20%
22%
24%
26%
28%
30%
32%
10% replac ement 20% replac ement
Wa
ter
of
No
rma
l C
on
sis
ten
cy
(%
)
TI
TI L S
TI S L X
TI C K D A
TI C K D B
TI C K D C
TI C K D D
TI C K D E
TI C K D F
(a)
20%
22%
24%
26%
28%
30%
32%
10% replac ement 20% replac ement
Wa
ter
of
No
rma
l C
on
sis
ten
cy
(%
) TII
TII L S
TII S L X
TII C K D A
TII C K D B
TII C K D C
TII C K D D
TII C K D E
TII C K D F
(b)
Figure 4.21 Water requirement for normal consistency of (a) Cement TI blends and (b)
Cement TII blends
(The legends are ordered top (left) to bottom (right) for the bar charts)
A B C D
E
F
A B
C D
E
F
A B C
D
E
F
A B C D
E
F
TI SLX LS
TI SLX LS
TII SLX LS TII SLX LS
198
Table 4.11 Range of change in water demand for normal consistency of pastes
PC % CKD
and Filler
Replacement
Fillers
w/b change
CKDs A, B, C, D
w/b increase
(CKDs from wet
and long-dry kilns)
CKDs E, F
w/b increase
(CKDs from
preheater/precalciner kilns)
10% 0.1% to 0.4% 0.4% to 0.8% 1.3% to 2.1% TI (26.4%)
20% 0.2% to 0.7% 1.1% to 1.6% 3.9% to 5.2%
10% 0.2% 1.2% to 1.6% 2.3 to 2.7% TII (24.0%)
20% 0.5% 2.3% to 2.7% 5.2% to 7.5%
Figure 4.22(a) shows the correlation of the normal consistency between all Cement TI
and Cement TII CKD blends. Figure 4.22(b) shows the same correlation with the
exception that blends with CKDs E and F were excluded. The very good correlation of
both indicates that the effects on normal consistency are a function of the CKD
composition.
Correlations between water demand for consistency of CKD-PC blends and various
independent variables were then conducted. The normal consistency water requirement as
a function of free lime for both Cement TI and TII CKD blends is shown in Figure 4.23.
The CKD-PC blends with the highest free limes also have the highest water demand. The
increased water demand, however, is not only due to the presence of high amounts of free
lime but also its reactivity. The free lime of preheater/precalciner process CKDs is
typically very reactive due to the low de-carbonation temperature, resulting in soft burnt
free lime. As discussed in Section 4.2.1.1, CKDs E and F have large amounts of very
reactive free lime, which is indicated by isothermal conduction calorimetry in the heat
evolved during initial hydrolysis.
199
0.22
0.24
0.26
0.28
0.3
0.32
TII C
KD
ble
nds
Norm
al C
onsis
tency (
%)
.26 .27 .28 .29 .3 .31 .32
TI CKD blends
Normal Consistency (%)
(a) Blends with all CKDs
0.22
0.24
0.26
0.28
0.3
0.32
TII C
KD
s (
A, B
, C
, D
)
Norm
al C
onsis
tency (
%)
.26 .265 .27 .275 .28 .285
TI CKDs (A, B, C, D)
Consistency (%)
(b) Blends with CKDs A, B, C, and D
Figure 4.22 Correlation between Cement TI and Cement TII blends with the same CKD
and replacement level for (a) all CKDs and (b) CKDs A, B, C, and D
r = 0.982
10%
20%
Control
PC Replacement
r = 0.967
10%
20%
Control
PC Replacement
200
0.22
0.24
0.26
0.28
0.3
0.32
w/b
@ N
orm
al C
onsi
stency,
%
0 2 4 6 8
Free CaO, %
(a)
0.22
0.24
0.26
0.28
0.3
0.32
w/b
@ N
orm
al C
onsis
tency, %
0 2 4 6 8
Free CaO, %
(b)
Figure 4.23 Water requirement for normal consistency as a function of free lime content
for (a) Cement TI CKD blends and (b) Cement TII CKD blends
r = 0.970
10%
20%
Control
PC Replacement
r = 0.958
10%
20%
Control
PC Replacement
201
The reason(s) for the effects of long-dry and wet kiln CKDs A, B, C, and D on increased
water demand in CKD-PC blends are not as clearly related to free lime. Attempts to
correlate water demand of the CKD-PC blends with CKDs A, B, C, and D to other
independent variables did not provide clear relationships. Since CKDs vary significantly
in composition, it is possible that there is more than one independent variable of CKD
that is impacting the water requirement. Besides the presence of free lime, an increase in
rate of ion dissolution could lead to greater overall chemical reactivity that requires
higher water demand.
Statements/Observations:
4.xxix For Cement TI and Cement TII, 10% replacement with CKDs A, B, C, and
D (wet and long-dry kiln CKDs) increased water demand by 1 – 3% and 5 –
7%, respectively. At 20% replacement of Cement TI and Cement TII, water
demand increased by 4 – 6% and 10 – 11%, respectively.
4.xxx CKDs with large amounts of highly reactive free lime (CKDs E and F) at
10% replacement of Cement TI and Cement TII increased the water demand
by 5 – 8% and 11 – 17%, respectively. At 20% replacement of Cement TI
and Cement TII with CKDs E and F, water demand increased by 15 – 20%
and 22 – 31%, respectively.
4.xxxi As the percent replacement of PC increased from 10% to 20% for CKDs A,
B, C, and D, water demand increased by 2 – 3% for Cement TI and 4 – 5%
for Cement TII, in comparison to the PC control. As percent replacement of
PC increased from 10% to 20% for CKDs E and F, water demand increased
by 9 – 11% for Cement TI and 10 – 12% for Cement TII. As filler
replacement levels increased from 10% to 20% of PC, the water demand
remained the same (± 1%).
202
4.2.2.2 Flow
The purpose of the flow test was to assess the impact of CKDs on the workability of the
CKD-PC mortar blends. A minimum of two flow measurements were taken for the PCs
and with CKD and filler as partial replacements of the PCs at a constant w/b ratio of
0.485. The average of the measurements for each mortar control and mortar blend is
presented in Figure 4.24. The statistical differences among the mortars for Cements TI
and TII were assessed using one-way analysis of variance (one-way ANOVA) and results
are presented in Appendix F.
Generally, the filler replacements increased flow while the CKD replacements reduced
flow. This indicates that the behaviour of the fillers is different from the impact of CKDs.
The LS and SLX blends had higher flow measurements at both 10% and 20%
replacement than that of the respective control PCs. As the percentage of each filler
replacement increased from 10% to 20% for both Cements TI and TII, the flow increased.
As the percentage of each CKD replacement increased from 10% to 20%, however, the
flow decreased. Some of the CKD blends at 20% replacement, however, had higher flow
than some CKD blends at 10% replacement with equivalent PC. The governing influence
of using CKD as a partial replacement of PC does not appear to be the percentage of
replacement.
At 10% replacement of Cement TI the flow of CKD blends were all lower than the
control with the exception of the blend with CKD D. The Cement TI with 10% CKD D
had a similar flow measurement to both filler blends at 10% replacement. However, at
20% replacement, all Cement TI CKD blends were lower than both the Cement TI alone
and filler blends. All Cement TII CKD blends had similar flow or were lower than that of
the Cement TII alone. Blends with CKD D had the highest flow in comparison to the
other CKD blends at an equivalent replacement level, while blends with the
preheater/precalciner CKDs E and F had significantly reduced flow.
203
50
60
70
80
90
100
110
120
10% replac ement 20% replac ement
Flo
w
TI
TI L S
TI S L X
TI C K D A
TI C K D B
TI C K D C
TI C K D D
TI C K D E
TI C K D F
(a)
50
60
70
80
90
100
110
120
10% replac ement 20% replac ement
Flo
w
TII
TII L S
TII S L X
TII C K D A
TII C K D B
TII C K D C
TII C K D D
TII C K D E
TII C K D F
(b)
Figure 4.24 Mortar flow of (a) Cement TI blends and (b) Cement TII blends
(The legends are ordered top (left) to bottom (right) for the bar charts)
A B
C
D
E
F
A
B C
D
E
F
A
B C
D
E
F
A
B
C
D
E
F
TI
SLX LS
TI
SLX LS
TII SLX LS
TII SLX
LS
204
The ASTM C109 requirement for mortar flow is 110 ± 5 of blended cement. The range of
flows for the filler and CKD blends at 10% and 20% for each PC are presented in Table
4.12. Cement TI control flow was 107, which is close to the lower limit of the required
range. Cement TII control flow was 114, however, which is close to the upper limit of the
required range. The flows of PC-filler blends were comparable (±3) at equivalent partial
replacements of the same PC. Filler replacements at 10% of Cement TI were within the
ASTM range, while all other blends with filler replacements were near or slightly above
the upper limit.
Blends with CKDs A, B, C, and D were separated from blends with CKDs E and F due to
the significant difference in the range of flows. At 10% replacement of Cement TI with
CKDs A, B, C, and D the flow measurements were all within the required range or
slightly below the lower limit. Cement TII blends with CKDs A, B, C, and D at 10%
replacement were all within the required range. At 20% CKD replacements of Cements
TI and TII, all blends were slightly above or below the lower limit of 105, with the
exception of Cement TI CKD B at 20% that had a flow of 95. Blends with CKDs E and F
at 10% replacement of PCs were only slightly below the lower limit, except for Cement
TI CKD F at 10% replacement, which was 94. Blends with CKDs E and F at 20%
replacement of Cements TI and TII, however, were well below the ASTM specified
range.
Table 4.12 Range of flow for all mortars
CKD
Replacement
Cement
Type
CKDs A, B, C, D
(CKDs from wet and
long-dry kilns)
Flow Range
CKDs E, F
(CKDs from
preheater/precalciner kilns)
Flow Range
Fillers
Flow Range
TI (107) 100 – 110 94 – 102 111 – 112 10 % replacement
TII (114) 109 – 113 100 – 103 116 –117
TI (107) 95 – 108 66 – 79 114–117 20% replacement
TII (114) 102 – 109 78 – 90 117–118
• Regular: All flows between 105 - 115
• Italic: All flows between 100 – 120
• Bold: Atleast one flow is below 100
205
Correlations between flow of CKD-PC blends and various independent variables were
conducted. The flow as a function of free lime for both Cement TI and TII CKD blends is
shown in Figure 4.25. Similar to the impact on water requirement for normal consistency,
the CKD-PC blends with the highest free lime contents also have the highest water
demand, resulting in low flow. As discussed in Sections 4.2.1.1 and 4.2.2.1, high amounts
of reactive free lime in CKDs E and F quickly combine with water to form calcium
hydroxide precipitates. The reduction in flow is likely due to the formation of these
precipitates. Scatter in the data below 2% free lime, however, indicates that factors other
than free lime are also involved.
Correlations were then investigated for flow of CKD blends excluding CKDs E and F and
other independent variables. As shown in Figure 4.26, the effects of fineness became
more pronounced for both Cements TI and TII CKD blends. The most pertinent findings
of the analysis are that the flow correlates well with the particle size fraction less than 30
µm for Cement TI CKD blends and less than 45 µm for Cement TII CKD blends. As the
percentage of finer particles below the respective size increases, so does the flow. This
apparently is in line with the results of the fillers, which also have higher 45 µm passing
and higher flow. CKD D also had the highest percentage of particles passing 45 µm and
the highest flows.
206
60
70
80
90
100
110
120
Flo
w
0 2 4 6 8
Free CaO, %
(a) Cement TI blends
60
70
80
90
100
110
120
Flo
w
0 2 4 6 8
Free CaO, %
(b)
Figure 4.25 Mortar flow as a function of free lime content for (a) Cement TI CKD blends
and (b) Cement TII CKD blends
(Encircled data points reflect scatter in the data below 2% free lime content)
r = -0.870
10%
20%
Control
PC Replacement
r = -0.926
10%
20%
Control
PC Replacement
207
90
95
100
105
110
115
Flo
w
74 75 76 77 78 79
Volume < 30.5 µm, %
(a)
100
102.5
105
107.5
110
112.5
115
Flo
w
86 87 88 89 90 91 92 93
45µm, % Passing
(b)
Figure 4.26 Mortar flow as a function of (a) percentage of volume less than 30.5 µm for
Cement TI CKD blends (excluding CKDs E and F) (b) percentage passing 45 µm for
Cement TII blends (excluding CKDs E and F)
r = 0.960
10%
20%
Control
PC Replacement
r = 0.892
10%
20%
Control
PC Replacement
208
The results from the present study indicate that the flows of CKD-PC mortar blends are
similar to or lower than PC alone. The role of CKD in reducing flow arises from the fact
that reactive free lime hydrates readily to form calcium hydroxide precipitates and/or
there is a smaller percentage of particle size less than 30.5 µm for Cement TI CKD
blends and 45 µm for Cement TII CKD.
Statements/Observations:
4.xxxii The CKD-PC blends had similar (±5%) or reduced flows (>5% reduction) in
comparison to the control PC alone. The PC-filler blends, however, had
similar or higher flows (2 – 9%) than PC alone.
4.xxxiii At 10% and 20% replacement of Cement TI with CKDs A, B, and C, flow
decreased by 3 – 7% and 5 – 11%, respectively. At 10% and 20%
replacement of Cement TI with CKD D, flow was similar to the respective
PC control (±3%). At 10% and 20% replacement of Cement TII with CKDs
A, B, C, and D, flow decreased by 1 – 4% and 4 – 11%, respectively.
4.xxxiv CKDs with large amounts of highly reactive free lime reduce the flow of a
CKD-PC blend significantly in comparison to control PC. At 10%
replacement of Cement TI and Cement TII with CKDs E and F, flow
decreased by 5 – 12% and 10 – 12%, respectively. At 20% replacement of
Cement TI and Cement TII with CKDs E and F, flow decreased by 26 –
38% and 21 – 32%, respectively.
4.xxxv In the absence of large amounts of highly reactive free lime (>20%), it
appears the flow is governed by the fineness properties of the blends.
Cement TI CKD blend flows as a function of the total particles of less than
30.5 µm by volume is a linear relationship with a positive slope. For Cement
209
TII CKD blends, the flow as a function of percentage of the total particles
less than 45 µm by mass is a linear relationship with a positive slope.
4.xxxvi As the percentage of PC replacement with CKDs A, B, C, and D increased
from 10% to 20%, the flow remained the same or decreased by 0-5% for
Cement TI and decreased by 3 – 9% for Cement TII. As the percentage
replacement of PC with CKDs E and F increased from 10% to 20%, the
flow decreased by 23 – 30% for Cement TI and 13 – 22% for Cement TII.
As the percentage of PC replacement with fillers increased from 10% to
20%, however, the flow marginally increased (1 – 4%).
210
4.2.2.3 Initial Setting Time
Concrete is traditionally a mixture of PC, water, and aggregate. The initial setting time of
PC is important as, in addition to workability, it provides an indication of how long the
mixture will remain in the plastic condition to allow for its transportation, placement, and
compaction under a variety of conditions. For economic and logistical reasons, it is
generally desirable for concrete to harden and develop strength within a reasonable time
after it has been placed. For these reasons, understanding the impact of CKD as a partial
replacement of PC on the initial setting time is essential.
The ASTM C191 procedure was modified to attain a setting time at five minute intervals
instead of 15 minute intervals. To assess the repeatability of the initial setting time
results, three samples for each control PC were tested. The setting times for Cement TI
were 120, 115, and 120 minutes. The setting times for Cement TII were 60, 55, and 60
minutes. This provides an indication of the level of repeatability to be expected in the
results of the setting times for all blends.
The setting times for the PC alone, CKD-PC blends, and PC-filler blends are shown in
Figure 4.27. The blends with LS and SLX had very similar setting times to that of the
respective cement alone specimens. Of the 14 Cement TI CKD blends, nine exhibited
similar or delayed setting times in comparison to that of the Cement TI control. Cement
TI CKD blends that consisted of CKDs C and D at both 10% and 20% replacement had
shorter setting times in comparison to Cement TI alone. CKD F at 10% replacement of
Cement TI delayed setting time, but at 20% replacement shortened setting time in
comparison to the Cement TI control. All of the setting times for the Cement TII CKD
blends were delayed in comparison to the control. The setting times of CKD-PC blends
increased or stayed the same when the level of CKD replacement increased from 10% to
20%, except blends with CKD F.
211
0
20
40
60
80
100
120
140
160
180
10% replac ement 20% replac ement
Init
ial
Se
t T
ime
(m
inu
tes
)
TI
TI L S
TI S L X
TI C K D A
TI C K D B
TI C K D C
TI C K D D
TI C K D E
TI C K D F
(a)
0
20
40
60
80
100
120
140
10% replac ement 20% replac ement
Init
ial
Se
t T
ime
(m
inu
tes
)
TII
TII L S
TII S L X
TII C K D A
TII C K D B
TII C K D C
TII C K D D
TII C K D E
TII C K D F
(b)
Figure 4.27 Initial set time for (a) Cement TI blends and (b) Cement TII blends
(The legends are ordered top (left) to bottom (right) for the bar charts)
A
B
C D
E F
A
B
C D
E
F
A B
C D
E
F
A
B
C D
E
F
TI SLX LS TI SLX
LS
TII
SLX LS
TII SLX LS
212
ASTM C150 allows the use of processing additions to meet the requirements of ASTM
C465 for use in the manufacture of hydraulic cements and states that the time of setting
(ASTM C191) shall not vary from that of the control cement by more than 60 minutes or
50%, whichever is the lesser. This requirement for setting time is one parameter that was
used to assess the acceptability of using CKDs as a partial replacement of PC in the
current standards.
The Cement TI control setting time was 120 minutes and, according to ASTM C465, the
acceptable setting time range for Cement TI with processing additions is between 60 and
180 minutes. All of the Cement TI CKD blends at both 10% and 20% replacement were
within the ASTM C465 specified range. The setting time with 10% CKD replacement of
Cement TI was between 105 and 130 minutes. The range of setting time with 20% CKD
replacement of TI was between 110 and 170 minutes.
The Cement TII setting time was 60 minutes and, according to ASTM C465, the
acceptable setting time range for Cement TII with processing additions is between 30 and
90 minutes. Three of the six Cement TII blends at 10% CKD replacement and two of the
six blends at 20% CKD replacement were within the acceptable range. The range of
setting times with 10% CKD replacement of Cement TII was between 70 and 100
minutes. The range of setting times with 20% CKD replacement of Cement TII was
between 80 and 125 minutes.
It is generally accepted that initial setting is controlled by the hydration of C3S to form C-
S-H. Under normal conditions, initial setting time and the transition from the heat of
hydration induction phase to the acceleration phase are related. Since it is difficult to
define this transition phase of the heat of hydration curve, the time at which the minimum
rate of heat evolution during the induction period, ti, is used as an indication of the time
at which the induction period occurs. The setting time as a function of the time of the
213
minimum rate of heat evolution during the induction period for both Cements TI and TII
CKD blends is shown in Figure 4.28.
As shown in Figure 4.28(a), the Cement TI CKD blends setting times correlate well with
the time that the minimum peak of the induction period occurred for blends that had
longer setting times than the TI control, indicating normal setting. The relationship
appears to be linear with a positive slope. The Cement TI CKD blends that resulted in
shorter setting times (TI CKD C 10 and 20%, TI CKD D 10 and 20%, and TI CKD F
20%), in comparison to Cement TI control, are circled in Figure 4.28(a). These data
points do not correlate well with time of the minimum rate of heat evolution during the
induction period. This indicates abnormal setting, which is typically caused by an
imbalance between alumina and sulfate ions. False set (a type of abnormal set) in the
Cement TI CKD blends with CKDs C and D is likely. This is due to either an excess of
sulfate in the liquid phase leading to secondary gypsum formation or excessive AFt
formation. CKD F was the only CKD that resulted in shortened settings times as the
replacement of both PCs increased from 10% to 20% replacement. These shortened
setting time are likely due to the large amount of highly reactive free lime resulting in
precipitation of Ca(OH)2 that causes an abnormal set similar to a flash set.
Figure 4.28(b) shows a strong relationship between the heat of hydration induction period
and the setting times for Cement TII CKD blends. Therefore, CKD F at 20% was
removed from the data set. The setting time as a function of the time of the minimum rate
of heat evolution during the induction period appears to be a linear relationship with a
positive slope, unless false or abnormal setting occurs. This indicates the difference
between hydration kinetics and the setting mechanism. This further reinforces false
setting as the case because normal setting is governed by C-S-H formation, which is
exhibited in the heat of hydration curve.
214
(a)
(b) Cement TII blends
(b)
Figure 4.28 Initial set time as a function of the time of minimum heat rate during the
induction period (ti) for (a) Cement TI CKD blends (excluding circled data points) and
(b) Cement TII CKD blends
40
60
80
100
120
140
Se
ttin
g t
ime
, m
inu
tes
1 1.25 1.5 1.75
time of induction, hours
100
120
140
160
180
Se
ttin
g t
ime
, m
inu
tes
1.25 1.5 1.75 2 2.25 2.5
time of induction, hours
r = 0.826
10%
20%
Control
PC Replacement
r = 0.795
10%
20%
Control
PC Replacement
Abnormal Set: TI CKD C 10% and 20% TI CKD D 10% and 20% TI CKD F 20%
215
Cement TII had a very short setting time, by industry standards. The paste false set test
(ASTM C451) was performed that indicated the short setting time was not due to false
set, but simply a quick set. As discussed in Section 4.2.1.1, the heat of hydration curves
for Cement TII showed that the sulfate depletion peak was superimposed on the main
hydration peak. This is an indication that inadequate soluble sulfate was available to
control the hydration of C3A to allow for normal setting to occur. It is likely that the early
sulfate depletion contributed to the hydration of C3A resulting in the quick set.
The setting time as a function of the soluble alkali content of the binder is shown in
Figure 4.29 for Cement TI CKD and Cement TII CKD blends. Although the setting is
influenced by many variables, the soluble alkali content of the CKD-PC blend is typically
of the greatest significance. Both time of induction from heat of hydration graphs and
initial setting times also correlate well with the alkali contents for the respective Cement
TI and Cement TII CKD blends. This strengthens the premise that alkalis retard the
normal hydration of C3S.
While, alkalis are widely reported to accelerate hydration of C3S, Osbaeck and Jons
(1980) stated that the accelerated effects of alkalis are diminished or absent if gypsum
(calcium sulfate) levels are above the optimum sulfate content. The present study
indicates that the sulfate contribution from CKDs behave similar to gypsum. Since CKDs
generally contain higher amounts of soluble sulfate than PC, the CKD-PC blends have
sulfate contents that are above the optimum sulfate level. Therefore, the finding that an
increase in alkali contribution from CKDs delays, rather than accelerates, hydration of
C3S is reasonable.
It is widely known that an increase in w/b for a given paste results in longer setting times.
Although the w/b ratio was higher for all CKD-PC blends than the PC, a relationship
between w/b and the setting times was not found. This finding is reasonable, however,
216
since the established influence of w/b refers to its effect on a single blend and not on
blends with different chemical/mineralogical and physical properties.
(a)
(b)
Figure 4.29 Initial set time as a function of soluble alkali content for (a) Cement TI
blends (excluding circled data points) and (b) Cement TII blends
r = 0.945
10%
20%
Control
PC Replacement
100
120
140
160
180
Se
t tim
e -
initia
l
.7 .8 .9 1 1.1 1.2 1.3
Sol. Alkalis (NaEq)
40
60
80
100
120
140
Se
t tim
e -
initia
l
.4 .5 .6 .7 .8 .9 1
Sol. Alkalis (NaEq)
r = 0.790
10%
20%
Control
PC Replacement
Abnormal Set: TI CKD C 10% and 20% TI CKD D 10% and 20% TI CKD F 20%
217
Statements/Observations:
4.xxxvii All of the Cement TI CKD blends at both 10% and 20% replacement were
within the ASTM C465 specified range. At 10% CKD replacement of
Cement TI, the initial setting times were ±12.5% of the Cement TI initial
setting time. At 20% CKD replacement of Cement TI, the initial setting
times were between 8% shorter and 42% longer than the initial setting
time of Cement TI. Three of the six Cement TII blends at 10% CKD
replacement and two of the six blends at 20% CKD replacement were
within the acceptable range. At 10% and 20% CKD replacement of
Cement TII, the initial setting times were 17 – 67% and 33 – 108% longer,
respectively, than the initial setting time of Cement TII.
4.xxxviii The setting time as a function of the binder alkali content appears to be a
linear relationship with a positive slope, unless abnormal setting occurs.
This implies that an increase in the CKD alkali content retards the normal
setting process that occurs as a result of C-S-H hydration.
4.xxxix Abnormal setting may occur with some CKDs as partial replacements of
PCs, which is likely due to excessive amounts of sulfate ions available
during early age hydration. The likely precipitates are AFt and/or calcium
sulfate. Large amounts of highly reactive free lime in CKDs may cause
precipitation of calcium hydroxide and also result in abnormal/early
setting times.
4.xl Initial setting time is delayed by the presence of CKDs, unless abnormal
initial set occurs. All Cement TI CKD blends met the ASTM C465
standards for setting time at 10% and 20% replacement. For the Cement
TII CKD blends, however, only some of the blends at 10% and 20% CKD
218
replacement levels were within the acceptable range. The difference is
perhaps due to the relatively large change in alkali content between the
Cement TII CKD blends and Cement TII in comparison to the Cement TI
CKD blends and Cement TI.
4.xli It is widely known that an increase in w/b for a given paste results in
longer setting times. Although the w/b ratio was higher for all CKD-PC
blends than for the PC control, a relationship between w/b and the setting
times was not found. This finding is reasonable since the established
influence of w/b refers to its effect on a single blend and not on blends
with different chemical/mineralogical and physical properties.
4.2.2.4 Compressive Strength
Compressive strength is perhaps the most important criterion for assessing PC quality.
Virtually every PC testing specification stipulates minimum strength requirements at
certain ages. The strength development of a cementitious system is influenced by the PC
type or, more specifically, the mineralogical and physical properties of the PC. As the
effects of CKD-PC blends on strength in comparison to the control PC are considered, it
is also important to assess the performance criterion for the CKD-PC blends in meeting
industry standards.
The compressive strengths of all mortars were determined at 1, 3, 7, 28, and 90 days. The
compressive strength at each age was determined using an average of three cube
measurements at a constant w/b ratio of 0.485. The statistical differences among the
mixes were assessed using one-way analysis of variance (one-way ANOVA), and they
are presented in Appendix G.
The average compressive strengths for each mortar control and blend are presented in
Figure 4.30 and Figure 4.31 and tabulated in Table G.2. The range of the CKD-PC and
219
PC-filler blend strengths are presented as a percentage of values for PC alone at each age
in Table 4.13 and Table 4.14. ASTM C150 states that PC must meet minimum
compressive strength requirements that increase at later ages. ASTM C465 states that
mortar compressive strengths (ASTM C109) of blends with partial replacement of PC
shall not be less than 95% of the control PC at all ages. Therefore, 95% of PC
compressive strength at the same age is considered an adequate level to assess
performance of the CKD-PC blends.
At 10% replacement of Cement TI (Figure 4.30a), all CKD-PC blends were more than
95% of the PC control except the blend with CKD D at the age of one day (73%). At 10%
replacement of Cement TII (Figure 4.31a), the lowest compressive strength of the CKD-
PC blends was only marginally below the 95% threshold of PC alone at all ages, with the
lowest at 93%. It should be noted that many of the CKD-PC blends at 10% CKD
replacement level of PC were higher than the respective PC alone at the same age, with
the highest at 115% for the Cement TI CKD blends and 112% for the Cement TII CKD
blends.
At 20% replacement of the PCs with CKDs, the range of CKD-PC compressive strengths
is much wider. For the Cement TI blends, all CKD-PC blends at one day were below
95% of the control cement. At all of the other ages, some blends are above and some
below the 95% threshold. At 90 days, the CKD-PC blends with Cement TI were only
marginally below (93 – 94%) or exceeded the 95% threshold for PC alone compressive
strength. For the Cement TII CKD blends, some blends are above and some below the
95% threshold at all ages.
The compressive strengths for Cement TI with LS at 10% and 20% replacement were
within the compressive strength range of the CKD-PC blends at equal levels of
replacement at all ages. At early ages (one and three days), the Cement TI SLX blend
compressive strengths were also within the range of the Cement TI CKD blends at equal
220
levels of replacement. At later ages (28 and 90 days), however, the Cement TI SLX blend
compressive strengths were lower than the range of the Cement TI CKD blend
compressive strengths at equal levels of replacement.
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
1 day 3 day 7 day 28 day 90 day
C u rin g T im e
Co
mp
res
siv
e S
tre
ng
th (
MP
a)
TI
TI L S 10%
TI S L X 10%
TI C K D A 10%
TI C K D B 10%
TI C K D C 10%
TI C K D D 10%
TI C K D E 10%
TI C K D F 10%
(a)
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
1 day 3 day 7 day 28 day 90 day
C u rin g T im e
Co
mp
res
siv
e S
tre
ng
th (
MP
a)
TI
TI L S 20%
TI S L X 20%
TI C K D A 20%
TI C K D B 20%
TI C K D C 20%
TI C K D D 20%
TI C K D E 20%
TI C K D F 20%
(b)
Figure 4.30 Mortar compressive strength of Cement TI blends at 1, 3, 7, 28, and 90 days
(w/b = 0.485) for (a) 10% replacement and (b) 20% replacement (w/b = 0.485)
221
(The legends are ordered top (left) to bottom (right) for the bar charts)
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
1 day 3 day 7 day 28 day 90 day
C u rin g T im e
Co
mp
res
siv
e S
tre
ng
th (
MP
a)
TII
TII L S 10%
TII S L X 10%
TII C K D A 10%
TII C K D B 10%
TII C K D C 10%
TII C K D D 10%
TII C K D E 10%
TII C K D F 10%
(a)
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
1 day 3 day 7 day 28 day 90 day
C u rin g T im e
Co
mp
res
siv
e S
tre
ng
th (
MP
a)
TII
TII L S 20%
TII S L X 20%
TII C K D A 20%
TII C K D B 20%
TII C K D C 20%
TII C K D D 20%
TII C K D E 20%
TII C K D F 20%
(b)
Figure 4.31 Mortar compressive strength of Cement TI blends at 1, 3, 7, 28, and 90 days
(w/b = 0.485) for (a) 10% replacement and (b) 20% replacement (w/b = 0.485)
(The legends are ordered top (left) to bottom (right) for the bar charts)
222
Table 4.13 Compressive strength range for CKD-PC blends as percent of PC alone
TI with 10%
CKD
replacement
TII with 10%
CKD
replacement
TI with 20%
CKD
replacement
TII with 20%
CKD
replacement
1 day 73 – 112% 93 – 109% 65 – 99% 78 – 102%
3 day 96 – 110% 94 – 106% 71 – 100% 71 – 96%
7 day 104 – 113% 94 – 108% 77 – 107% 74 – 103%
28 day 101 – 114% 93 – 104% 90 – 100% 84 – 102%
90 day 99 – 115%
97 – 100% 94 – 114% 89 – 96%
1. Bold: all CKD-PC blends greater than or equal to 95% f’c of PC alone
2. Regular: at least one CKD-PC blend within 90 to 95% f’c of PC alone 3. Italics: at least one CKD-PC blend less than 90% f’c of PC alone
Table 4.14 Compressive strength range for PC-filler blends as percent of PC alone
TI with 10%
filler
replacement
TII with 10%
filler
replacement
TI with 20%
filler
replacement
TII with
20% filler
replacement
LS SLX LS SLX LS SLX LS SLX
1 day 93% 96% 93% 88% 78% 83% 80% 80%
3 day 103% 95% 95% 87% 89% 83% 81% 81%
7 day 105% 98% 104% 85% 94% 88% 89% 72%
28 day 103% 97% 97% 83% 92% 88% 82% 74%
90 day 110% 97% 97% 83% 94% 87% 82% 73%
1. Bold: all PC-filler blends greater than or equal to 95% f’c of PC alone
2. Regular: at least one PC-filler blend within 90 to 95% f’c of PC alone 3. Italics: at least one CKD-PC blend less than 90% of f’c of PC alone
223
The compressive strengths for Cement TII with LS at 10% and 20% replacement were
within the compressive strength range of the Cement TII CKD blends at equal levels of
replacement at all ages. The compressive strengths for Cement TII with SLX at 10%
replacement, however, were lower than the compressive strength range of the Cement TII
CKD blends at equal levels of replacement. At one and three days, Cement TII with SLX
at 20% replacement was within the compressive strength range of the Cement TII CKD
blends. At 7, 28, and 90 days, however, Cement TII with SLX at 20% replacement
compressive strengths was lower than the compressive strength range of the Cement TII
CKD blends at equal levels of replacement.
The CKD-PC blends that had higher strengths at one day generally decreased at 7, 28 and
90 days compared to PC alone. Conversely, the CKD-PC blends that had lower strengths
at one day generally increased at 7, 28, and 90 days compared to PC alone. Generally
speaking, the CKD-PC blends had comparable compressive strengths to PC-LS blends
and higher compressive strengths than PC-SLX blends at equal levels of replacement.
Cement TI CKD blends at one and three day compressive strength have a linear
relationship with a negative slope as a function of the binder SO3 content, as shown in
Figure 4.32. The only known sulfate form to have this effect on PC compressive strength
is calcium sulfate in the form of gypsum. As discussed in Section 2.4.6, the observed
optimum sulfate content in the strength curve implies that the addition of gypsum
involves two opposing effects. The first, which predominates in the lower range of SO3
content, has a beneficial effect on strength. The second, which predominates in the range
of SO3 greater than the optimum, has an adverse effect on compressive strength. This
results in a bell-curve relationship for compressive strength as a function of SO3 content.
The heat of hydration analysis shows that Cement TI has normal sulfate levels to control
aluminate hydration. Therefore, it is expected that excess calcium and sulfate ions
provided by the CKD fraction of the binder will contribute to adverse effects on one day
strengths.
224
10
15
20
25
30
Mo
rta
r C
om
pre
ssiv
e
Str
en
gth
@ 1
da
y,
MP
a
4 4.5 5 5.5 6 6.5 7
SO3, %
(a)
10
15
20
25
30
Mo
rta
r C
om
pre
ssiv
e
Str
en
gth
@ 3
da
y,
MP
a
4 4.5 5 5.5 6 6.5 7
SO3, %
(b)
Figure 4.32 Mortar compressive strength as a function of total sulfate content for Cement
TI CKD blends at (a) 1 day and (b) 3 days (w/b = 0.485)
r = -0.900
10%
20%
Control
PC Replacement
10%
20%
Control
PC Replacement
r = -0.830
225
The one and three day strength relationship with SO3 content for the Cement TII CKD
blends also support the finding that CKD can behave in a similar manner to gypsum
during early-age hydration, as shown in Figure 4.33. From the heat of hydration analysis,
the main hydration and sulfate depletion peaks overlap (occur simultaneously) indicating
that insufficient calcium and sulfate ions were available to control aluminate hydration.
As the sulfate content of the Cement TII CKD blends increased, the one day strength
initially increased but then assumed a negative linear slope. Therefore, the data points
suggest a bell curve very similar to that seen with the addition of calcium sulfate in the
form of gypsum (see Figure 2.7). Two commonly suggested mechanisms of excessive
sulfates are: (i) excessive AFt formation and (ii) accelerated hydration of alite but lower
C-S-H intrinsic strength due to incorporation of SO3 into its structure. Gartner et al.,
(2002) have stated that both mechanisms may contribute to the phenomenon caused by
excessive calcium sulfate. Cement TII has low aluminate content. Therefore, the linear
negative slope relationship as a function of increasing sulfate content for the Cement TII
CKD blends is most likely due to affects on C-S-H, rather than AFt formation at one day
strength.
The effect of increased alkali content is widely reported to increase early strengths and
reduce later strengths. This effect is significantly diminished, however, as the gypsum
content exceeds the optimum sulfate level. Since the presence of CKD appears to
increase the amount of calcium and sulfate ions in solution during early age hydration, it
is not surprising that the effect of alkalis from CKDs does not appear to impact early age
compressive strength. In the absence of high CKD sulfate content, other contributing
factors may govern effects on early age strength. For example, CKD A (low sulfate and
high chloride contents) increased early age strengths, likely due to the accelerating effect
of chlorides.
226
(a)
(b)
Figure 4.33 Mortar compressive strength as a function of total sulfate content for Cement
TII CKD blends at (a) 1 day and (b) 3 days (w/b = 0.485)
Note: Straight line is a linear best fit. Curve is a polynomial best fit.
r = -0.867 (linear fit)
10%
20%
Control
PC Replacement
r = -0.798 (linear fit)
10%
20%
Control
PC Replacement
227
The Cement TI CKD blend 28 day compressive strengths as a function of the percentage
of material passing 45 µm sieve is shown in Figure 4.34. Cement TI CKD blend 28 day
strengths had a linear relationship with a negative slope as a function of percentage
passing the 45 µm sieve. The Cement TI CKD blend 28 day compressive strengths as a
function of the calcium carbonate content are shown in Figure 4.33. Cement TII CKD
blends had a linear relationship with a negative slope as a function of calcium carbonate
content. As discussed previously for the calcite filler, calcium carbonate as a partial
replacement of low C3A cements acts as a diluent. The CKD contribution of calcium
carbonate likely reacts with the aluminate hydrates in Cement TI, whereas Cement TII
has much lower aluminate hydrate content. Scatter in the data for the relationships at 28
day compressive strengths indicates that other factors also influence CKD-PC blend
strength at this age.
A linear relationship for 7 day and 90 day strengths was not evident for the CKD-PC
blends. It is likely a combination of contributing factors that influence the strength
development of CKD-PC blends at these ages.
228
30
32
34
36
38
40
42
Mo
rta
r C
om
pre
ssiv
e
Str
en
gth
@ 2
8 d
ay,
MP
a
88 90 92 94 96
45µm, % Passing
Figure 4.34 Mortar compressive strength at 28 days as a function of percentage passing
45 µm for Cement TI CKD blends
30
32
34
36
38
40
42
Mo
rta
r C
om
pre
ssiv
e
Str
en
gth
@ 2
8 d
ay,
MP
a
0 2.5 5 7.5 10 12.5
Calcite, %
Figure 4.35 Mortar compressive strength at 28 days as a function of calcite for Cement
TII CKD blends (w/b = 0.485)
r = 0.652
10%
20%
Control
PC Replacement
r = -0.789
10%
20%
Control
PC Replacement
229
Statements/Observations:
4.xlii The compressive strength measurements for all Cement TI blends with 10%
CKD replacement were higher than 95% of the PC mortar control, with the
exception of only one blend at the age of one day. All of the compressive
strength measurements for Cement TII blends with 10% CKD replacement
were higher than 93% of the mortar plain control. Many of the CKD-PC
blends compressive strengths were 5 – 15% higher than that of the
respective control PC.
4.xliii All blends made with 10% CKD showed higher strengths at all ages
compared to the blends made with the same CKD at 20%. Therefore, the
replacement level is a factor to consider for the compressive strength effect
for a particular CKD. Some of the blends with CKDs at 20% replacement,
however, performed better than other CKDs at 10% replacement of PC. For
example, CKD A at 20% replacement of Cement TI had higher one day
compressive strength than CKDs B, C, D, and E at 10% replacement of
Cement TI. This is likely due to the high chloride and low sulfate contents
of CKD A. Consequently, the effect on the compressive strength of different
CKDs is related to the composition of the CKD-PC blend as well as the
replacement level.
4.xliv The blends with CKDs D, E, and F had low early compressive strengths but
at later ages had compressive strengths comparable to the PC mixes.
Excessive calcium sulfate in the form of gypsum is known to have this
effect on compressive strength development. Therefore, the sulfate from
CKDs D, E, and F is likely the reason for the lower early strengths and
higher late strengths.
230
4.xlv The CKD-PC blends compressive strengths were comparable to that of PC-
LS blends and higher than PC-SLX blends at both 10% and 20%.
4.xlvi The early age compressive strength is governed by the presence of soluble
calcium and sulfate. The one and three day compressive strength of the
Cement TI CKD blends each have a linear relationship with a negative slope
as a function of the binder SO3 content. The one and three day compressive
strength of the Cement TII CKD blends each appear to have a bell-curve
relationship as a function of the binder SO3 content. It seems the sulfate
content of CKD has a similar impact to the sulfate from gypsum (calcium
sulfate).
4.xlvii In the absence of high CKD sulfate content (CKD sulfate content ≤ PC
sulfate content), chlorides from CKDs increase early age strengths.
4.xlviii Cement TI CKD blend 28 day strengths had a linear relationship with a
negative slope as a function of percentage passing 45 µm sieve. Cement TII
CKD blends had a linear relationship with a negative slope as a function of
calcium carbonate content. The CKD contribution of calcium carbonate
likely binds with the aluminate hydrates in Cement TI, whereas Cement TII
has much lower aluminate hydrate content.
4.2.3 Volume Stability and Durability
4.2.3.1 Expansion in Limewater
The expansion in limewater test (ASTM C1038) is typically used to assess the stability of
mortars due to the presence of calcium sulfate. The expansions in limewater of all
mortars were determined after 14 days. The expansion for PC alone and for blends with
CKD and filler as partial replacements of PC was determined using an average of four
231
mortar specimens. The statistical differences among the mixes were assessed using one-
way analysis of variance (one-way ANOVA) and are presented in Appendix H.
The expansion in limewater for each mortar control and blend is presented in Figure 4.36.
All of the CKD-PC blends had higher expansions than that of the PC alone and filler
blends. The expansion in limewater was similar or higher as the percentage of CKD
replacement increased from 10% to 20%. As the percentage of LS and SLX in the blends
increased from 10% to 20% the expansions were similar. All blends with fillers had
essentially the same levels of expansion (0.003 to 0.008%).
The allowable limit of mortar expansion in limewater is 0.020% for CSA A3001, ASTM
C150, and ASTM C1157. CKDs A, B, and C were below the 0.020% threshold at both
10% and 20% replacement levels of Cement TI and TII. At 10% replacement, CKD D
with both Cements TI and TII and CKD E with Cement TI were higher than 0.020%. At
20% replacement, CKDs D, E, and F with Cements TI and TII were higher than 0.020%.
It is important to note that some of the blends with CKD replacement at 20% had much
lower expansion than blends with 10% replacement, for the same control cement.
The expansion is most significantly correlated to sulfate content in both Cement TI CKD
and Cement TII CKD blends, as shown in Figure 4.37. The expansion in limewater of
CKD-PC blends after 14 days as a function of binder sulfate content is a positive linear
slope. The expansion in limewater is mostly due to the formation of AFt in the hardened
paste. AFt formation requires the presence of C3A. CKD blends with Cement TI had
higher expansions than blends with Cement TII. This can be explained by the higher
levels of C3A in Cement TI than in Cement TII. Scatter in the data implies there could be
factors other than sulfate content that contribute to expansion in limewater.
The linear slope for the Cement TI CKD blends in Figure 4.37(a) indicates that the
expansion in limewater exceeds 0.020% at a sulfate content of approximately 4.75%.
232
Therefore, since the Cement TI sulfate content at 4.35% is optimized according to the
heat of hydration analysis (see Section 4.2.1.1), the expansion in limewater exceeds the
0.020% limit when the Cement TI CKD blend sulfate content is approximately 0.40%
above the optimum Cement TI sulfate content. The linear slope for the Cement TII CKD
blends in Figure 4.37(b) indicates that the expansion in limewater exceeds 0.020% at a
sulfate content of approximately 3.75%. The Cement TII sulfate content at 2.98% is
under-sulfated according to the heat of hydration analysis (see Section 4.2.1.1). The
CKD-PC expansion in limewater exceeds the 0.020% limit when the Cement TII CKD
blend sulfate content is approximately 0.75% above the Cement TII sulfate content.
233
0.00
0.02
0.04
0.06
0.08
0.10
0.12
0.14
10% replac ement 20% replac ement
Ex
pa
ns
ion
in
Lim
ew
ate
r (%
)
TI
TI L S
TI S L X
TI C K D A
TI C K D B
TI C K D C
TI C K D D
TI C K D E
TI C K D F
(a)
0.00
0.02
0.04
0.06
0.08
0.10
0.12
0.14
10% replac ement 20% replac ement
Ex
pa
ns
ion
in
Lim
ew
ate
r (%
)
TII
TII L S
TII S L X
TII C K D A
TII C K D B
TII C K D C
TII C K D D
TII C K D E
TII C K D F
(b)
Figure 4.36 Expansion in limewater after 14 days for (a) Cement TI blends and (b)
Cement TII blends
(The legends are ordered top (left) to bottom (right) for the bar charts)
A B C
D E F
A B C
D E
F
A B C
D
E
F A
B C
D
E
F
TI SLX LS TI SLX LS
TII SLX LS TII SLX LS
234
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
Exp
an
sio
n in
Lim
ew
ate
r, %
4 4.5 5 5.5 6 6.5 7
SO3, %
(a)
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
Exp
an
sio
n in
Lim
ew
ate
r, %
2.5 3 3.5 4 4.5 5 5.5 6
SO3, %
(b)
Figure 4.37 Expansion in limewater at 14 days as a function of sulfate content for (a)
Cement TI CKD blends and (b) Cement TII CKD blends
r = 0.936
10%
20%
Control
PC Replacement
r = 0.870
10%
20%
Control
PC Replacement
TI CKD D 10% and 20% TI CKD E 10% and 20% TI CKD F 20%
TII CKD D 20% TII CKD E 20% TII CKD F 20%
ASTM maximum limit
ASTM maximum limit
235
Statements/Observations:
4.xlix At 10% CKD replacement of Cement TI the expansions in limewater were 35
– 765% higher than the expansion in limewater of Cement TI. At 20% CKD
replacement of Cement TI the expansions in limewater were 115 – 2400%
higher than the expansion in limewater of Cement TI. At 10% CKD
replacement of Cement TII the expansions in limewater were 110 – 314%
higher than the expansion in limewater of Cement TII. At 20% CKD
replacement of Cement TII the expansions in limewater were 133 – 914%
higher than the expansion in limewater of Cement TII.
4.l Blends with CKDs A, B, and C gave expansions in limewater below the
ASTM C1038 maximum limit of expansion at both 10 and 20% replacement
of Cements TI and TII. Blends with CKDs D, E, and F, however, exceeded
the 0.020% limit. This is due to the significantly higher sulfate contents of
CKDs D, E, and F in comparison to CKDs A, B, and C. It appears that the
amount of CKD replacement of a PC is limited by the CKD-PC sulfate
content, which is to be less than approximately 0.40% above the optimum
sulfate content of the PC.
4.li Some blends with 20% CKD replacement had less expansion in limewater
after 14 days than other blends with 10% CKD replacement. This indicates
that the composition of the CKD-PC blend is more of a governing factor for
expansion in limewater than the level of PC replacement with CKD.
4.lii Expansion of CKD-PC mortars in limewater after 14 days as a function of
binder sulfate content is a positive linear slope. It is hypothesized that the
CKDs contribute excess calcium and sulfate ions to form higher amounts of
AFt than the control PC alone.
236
4.liii Cement TII CKD blends had less expansion in limewater after 14 days than
the Cement TI CKD blends due to the lower aluminate content in Cement TII,
in comparison to Cement TI.
4.2.3.2 Autoclave Expansion
Soundness is the ability of hardened cement paste to retain volume after setting.
Soundness issues generally result from the delayed or slow hydration of magnesium
oxide (MgO) and/or calcium oxide (CaO free lime). It is essential that cement paste, once
it has set, does not undergo a large change in volume; in particular there must be no
appreciable expansion, which, under condition of restraint, could result in a disruption of
the hardened cement paste.
The amount of CKD and filler in each paste was fixed at 10% and 20% by mass of PC,
with a w/b ratio that varied to maintain normal consistency. To assess the repeatability of
the autoclave expansion tests, repeat samples for each control PC were performed, as
shown in Table 4.15. This provides an indication for the level of repeatability to be
expected in the results of the autoclave expansion for all tests.
Table 4.15 Autoclave expansions for (a) Cement TI and (b) Cement TII
(a)
PC Autoclave
Expansion (%)
TI 0.040
TI 0.042
TI 0.038
TI 0.035
(b)
PC Autoclave
Expansion (%)
TII 0.055
TII 0.057
237
The autoclave expansion for each paste control and blend is presented in Figure 4.38. All
of the CKD-PC blends had similar or higher expansion than that of the PC alone or the
filler blends. The blends with filler materials had marginally lower expansions than PC
alone. The autoclave expansion was similar or higher than the percentage of CKD
replacement increased from 10% to 20%. As the percentage of LS and SLX in the blends
increased from 10% and 20%, the expansions decreased. Some blends with 20% CKD
replacement had less autoclave expansion than other blends with 10% CKD replacement.
This indicates that the composition of the CKD-PC blend is more of a governing factor
for autoclave expansion than the level of PC replacement with CKD.
The ranges for autoclave expansions of the CKD-PC blends are shown in Table 4.16. The
free lime contents of the CKD-PC blends are higher than PC alone. Since the free lime
contents of CKD-PC blends vary significantly, however, the results were separated into
blends made with high and low free lime CKDs. All of the CKD-PC blends were well
below the ASTM C150 limit of 0.80% and CSA A3001 limit of 1.0%. Therefore, all
CKD-PC blends are acceptable in terms of long-term soundness/durability from the
viewpoint of undesirable autoclave expansion according to ASTM C150.
ASTM C465, the specification for processing additions, however, states that the impact
shall not be more than 0.10% greater than the expansion of the control cement. Blends
with 10% CKD replacement were generally within this range for the two PCs, as required
in ASTM C465. Some blends with 20% CKD replacement were below the 0.10%
expansion of the cement alone, while others were higher. The CKD-PC blends that were
within the 0.10% expansion range of the PC had low free lime contents. Therefore, CKDs
with very high free lime contents may still meet the ASTM C465 requirement for
soundness at 10% replacement of PC.
238
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
10% replac ement 20% replac ement
Au
toc
lav
e E
xp
an
sio
n (
%)
TI
TI L S
TI S L X
TI C K D A
TI C K D B
TI C K D C
TI C K D D
TI C K D E
TI C K D F
(a)
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
10% replac ement 20% replac ement
Au
toc
lav
e E
xp
an
sio
n (
%)
TII
TII L S
TII S L X
TII C K D A
TII C K D B
TII C K D C
TII C K D D
TII C K D E
TII C K D F
(b)
Figure 4.38 Autoclave Expansions for (a) Cement TI blends and (b) Cement TII blends
(The legends are ordered top (left) to bottom (right) for the bar charts)
C
A
B C
D
E
F
A
B
C
D
E
F
A B
C
D
E
F A B
C
D
E
F
TI
SLX LS
TI
SLX LS
TII
SLX LS
TII
SLX
LS
239
Table 4.16 Range of autoclave expansions for all blends
Cement Type CKD
Replacement
CKDs A, B, C,
(low free lime content)
Expansion Change (%)
CKDs D, E, F
(high free lime content)
Expansion Change (%)
10% -0.009 to 0.021 0.024 to 0.091 Cement TI
20% 0.003 to 0.037 0.057 to 0.192
10% 0.016 to 0.051 0.026 to 0.112 Cement TII
20% 0.029 to 0.105 0.083 to 0.325
Bold: At least 1 sample is greater than 0.10% than the control PC
The autoclave expansion is most significantly correlated to free lime content for both
Cement TI CKD and Cement TII CKD blends, as shown in Figure 4.39. The autoclave
expansion of CKD-PC blends as a function of binder free lime content is a positive linear
slope. The expansion is mostly due to the formation of calcium hydroxide in the hardened
paste. It should be noted that CKD-PC blends with CKD F were excluded from the
regression analysis, but the data points are still shown (encircled) in Figure 4.39.
Although CKD F had the highest free lime, it did not have the highest expansion.
Soundness cannot always be predicted reliably from free lime content of a CKD-PC
blend, since its hydration reactivity is a function of its decarbonation temperature. CKD F
is from a preheater/precalciner pyroprocess which calcinates CKDs at a lower
temperature than that of wet and long-dry kiln CKDs. Free lime that has been
decarbonated at low temperatures readily reacts with water in the plastic paste (see Figure
2.9) and, therefore, does not contribute to autoclave expansion in the hardened paste. The
excessive heat evolution during initial hydrolysis, increased water demand, and decreased
flow of blends with CKD F all indicated that the free lime content was very reactive, as is
expected for a CKD from a preheater/precalciner.
Scatter in the data implies there could be other factors than free lime content that
contribute to autoclave expansion, such as reactivity of free lime (as discussed above).
240
0
0.1
0.2
0.3
0.4
Au
tocla
ve
Exp
an
sio
n,
%
0 2 4 6 8
Free CaO, %
(a)
0
0.1
0.2
0.3
0.4
Au
tocla
ve
Exp
an
sio
n,
%
0 2 4 6 8
Free CaO, %
(b)
Figure 4.39 Autoclave expansion as a function of free lime content (excluding data points
in the circles) for (a) Cement TI CKD blends and (b) Cement TII CKD blends
r = 0.975
10%
20%
Control
PC Replacement
r = 0.938
10%
20%
Control
PC Replacement
CKD F
blends
CKD F
blends
241
Statements/Observations:
4.liv At 10% CKD replacement of Cement TI the autoclave expansions were
between 22% lower and 228% higher than the autoclave expansion of Cement
TI. At 20% CKD replacement of Cement TI the autoclave expansions were 7-
480% higher than the autoclave expansion of Cement TI. At 10% CKD
replacement of Cement TII the autoclave expansions were 29-191% higher
than the autoclave expansion of Cement TII. At 20% CKD replacement of
Cement TII the autoclave expansions were 47-591% higher than the autoclave
expansion of Cement TII.
4.lv The CKD-PC blends had similar or higher autoclave expansions than PC
alone, but all were well below the ASTM C150 specification of 0.80%. PC-
filler blends had slightly lower autoclave expansion levels than PC alone.
4.lvi Some blends with 20% CKD replacement had less autoclave expansion than
other blends with 10% CKD replacement. This indicates that the composition
of the CKD-PC blend is more of a governing factor for autoclave expansion
than the level of PC replacement with CKD.
4.lvii Blends with 10% CKD replacement were typically within 0.10% expansion of
the two PC controls, as required in ASTM C465. Some blends with 20%
replacement CKD were below the 0.10% expansion of the cement alone,
while others were higher. The CKD-PC blends that were similar or below
0.10% expansion of the PC alone had low free limes (< ~ 4%).
4.lviii Expansion of CKD-PC pastes in the autoclave expansion as a function of free
calcium oxide binder content has a positive linear slope. It is hypothesized
that the CKDs contribute hard burnt free lime that hydrates to form higher
242
amounts of calcium hydroxide than from the control PC alone. The expansion
of hydrating lime is caused by crystallization of Ca(OH)2. Scatter in the linear
relationship with free lime content indicates that other factors may contribute
to unsoundness, such as the reactivity of the free lime.
4.lix Soundness cannot always be predicted reliably from the free lime content of a
CKD-PC blend since its hydration reactivity is a function of its decarbonation
temperature. Free lime that has been decarbonated at low temperatures readily
reacts with water in the plastic paste and therefore does not contribute to
expansion in the hardened paste.
4.2.3.3 Alkali Silica Reactivity
This program was designed to develop an understanding of the effects of CKD and is not
aimed at addressing the ASR mitigation of mixes incorporating CKDs. The objective was
to determine the influence of different types of CKD on ASR expansion tests. One of the
concerns with the CSA A23.2-14A ASR test for expansion is that the NaOH is used to
offset the sodium equivalent alkali (Na2Oe) level to a constant value of 5.25 kg/m3. This
study attempts to assess the impact of CKDs on CSA A23.2-14A concrete prism
expansions.
The details of the concrete mixes within the two test series are shown in Table 4.17. For
Test Series I, CKD replacement was constant at 10% of Cement TI and the amount of
NaOH addition varied to attain the desired Na2Oe loading of 5.25 kg/m3 in concrete
(based on the alkali content of both the PC and CKD). For Test Series II, the NaOH
addition was kept constant for the CKD-PC blends but the amount of CKD replacement
varied. Due to its lower alkali content, the TII series of blends required much more
NaOH addition to bring the alkali loading of each blend to 5.25 kg/m3 than the TI series
of blends .
243
Table 4.17 ASR concrete mix alkali loadings and CKD replacement levels for (a) Test
Series I: Cement TI CKD blends and (b) Test Series II: Cement TII CKD blends
(a)
Cement TI Blends Na2Oe loading in binder
(%)
Binder
(kg/m3)
NaOH
(kg/m3)
Expansions (%)
1 year 2 years
Cement TI - CTL 1 1.25 420 1.518 0.130 0.193
CKD A 10% 1.25 420 0.542 0.174 0.262
CKD B 10% 1.25 420 0.054 0.146 0.248
CKD C 10% 1.25 420 0.813 0.157 0.224
CKD D 10% 1.25 420 0.651 0.167 0.224
CKD E 10% 1.25 420 0.163 0.174 0.258
CKD F 10% 1.25 420 0.542 0.163 0.257
Cement TI - CTL 2 1.38 378 2.013 0.142 0.202
All blends had 5.25 kg/m3 of Na2Oe in concrete mix
(b)
Cement TII Blends Na2Oe loading in binder
(%)
Binder
(kg/m3)
NaOH
(kg/m3)
Expansions (%)
1 year 2 years
Cement TII - CTL 1 1.25 420 3.633 0.182 0.262
CKD A 9.8% 1.25 420 2.452 0.173 0.227
CKD B 7.0% 1.25 420 2.452 0.189 0.253
CKD C 12.9% 1.25 420 2.452 0.175 0.240
CKD D 10.9% 1.25 420 2.452 0.197 0.258
CKD E 7.7% 1.25 420 2.452 0.213 0.297
CKD F 10.1% 1.25 420 2.452 0.191 0.247
Cement TII - CTL 2 1.03 420 2.452 0.149 0.211
All blends had 5.25 kg/m3 of Na2Oe in concrete mix except Cement TII CTL 2 which had 4.34 kg/m3.
244
The ASR expansion tests for Test Series I and II are shown in Figure 4.40. For Test
Series I, the CKD-PC blends had higher expansions after two years in comparison to both
of the controls with PC alone. This implies that either (i) the alkali contribution from
CKDs causes more ASR expansion than the contribution of alkalis from NaOH addition,
or (ii) there are factors other than ASR that cause expansion to occur. It is reasonable to
assume that expansions due to high sulfate and free lime contents found in CKDs
contribute to expansion during the ASR test. A series of tests using two cement types
indicates that CKD can have a pronounced effect on ASR expansion tests, but it is
dependent on factors other than alkali level.
For Test Series II, the CKD-PC blends had similar or lower expansions after two years in
comparison to Cement TII CTL 1, with the exception of the blend with 7.7% CKD E.
The ASR expansion results in the Test TII series indicate that for an equivalent alkali
loading, NaOH is more reactive than Cement TII alkalis but less reactive than the alkalis
in CKDs or other CKD factors.
Statements/Observations:
4.lx CKDs can increase the expansion in the CSA A23.2-14A ASR concrete prism
test. This effect, however, is likely dependent on factors other than alkali
level. High sulfate and free lime contents can also influence the amount of
expansion during the ASR test.
245
(a)
(b)
Figure 4.40 ASR expansions over 2 years for (a) Test Series I: Cement TI CKD blends
and (b) Test Series II: Cement TII CKD blends
246
5.0 MAIN CONTRIBUTIONS OF THE THESIS
5.1 CKD Characterization
Studies have shown that CKDs can be interground or blended as a partial substitute of PC
between 5% and 15%, by mass. Although the use of CKDs is promising, there is very
little understanding of their effects on concrete. Previous studies provide variable and
often conflicting results. The reasons for the inconsistent results are not obvious due to
the lack of compositional data provided in the literature. It was also found that
compositional analysis procedures designed for PC are sometimes inappropriate to
determine the characteristics of CKDs. The characteristics of a CKD must be well-
defined in order to understand its potential impact in concrete.
A wide range of CKDs from different kiln processes were studied to assess overall CKD
characterization. Within the range of materials used in this study, the following main
contributions towards CKD characterization are:
1. The present study identifies the appropriate chemical and physical analytical
methods that should be used for accurate CKD composition analysis. CKDs must
be prepared and analyzed differently from PCs for accurate chemical and physical
analysis. This will assist other researchers and the industry in properly
characterizing their CKDs in future.
2. A greater understanding of the fineness properties of CKDs has resulted from this
investigation. Due to the lack of a size selection process, CKDs have a broader
particle size range than PCs. Also, the Blaine fineness of a CKD is largely
representative of the percentage of particles of less than 10 µm while the
percentage passing the 45 µm sieve is more representative of the percentage of
particles between 10 and 100 µm. This will help researchers correctly interpret the
fineness test results typically used for CKDs.
247
3. A process flow diagram to determine the relative abundance of the different
phases within CKDs was introduced. The characteristics of CKDs are
traditionally evaluated based on chemical analysis data. Such data does not,
however, indicate the ways in which the different elements actually exist within
the CKD and how they might be expected to react during hydration. Alkalis, for
example, may occur as separate crystalline phases in the form of alkali chlorides
or alkali sulfates. The reactivity of elements may therefore be expected to vary,
depending on the form in which they actually exist.
4. CKDs consist of clinker phases, calcium carbonate, quartz, clays, free lime,
portlandite, periclase, alkali chlorides, alkali sulfates, anhydrite, calcium
langbeinite, fly ash, and/or slag. Some of the phases identified in the CKDs had
not been previously recognized in the literature (i.e., calcium langbeinite) and can
influence hydration significantly.
5. The initial dissolution of ionic species in water and the composition of the liquid
phase play an important role in PC hydration. The availability of ions during the
initial minutes of hydration was used to assess the differences in reactivity
between various types of CKDs and PC. CKDs generally provide the same ions as
PC during initial dissolution, except some CKDs may also contribute chloride
ions. Calcium chloride, however, is commonly used as an accelerator in non-
reinforced concrete in cold weather. Other than the impact of chlorides, this
implies that CKD-PC blends could perform in similar manner to PC alone.
248
5.2 CKD-PC Blends
CKDs contain various components that affect performance and durability properties
when used as a partial replacement of PC. The chemical, physical, and mineralogical
properties of CKDs vary considerably between different cement plants and even within
the same plant. Therefore, it has been difficult to separate the effects of individual CKD
components on CKD-PC blends. Although the single effect of any one of the common
components found in CKDs can be stated in general terms, specific reactions among
more than one component are sometimes difficult to predict. Improved understanding of
the CKD-PC interaction will allow for optimization and increased utilization of these
blends in concrete.
The majority of previous CKD-PC research has generally used only one or two CKDs
and one PC (Table 2.10). Since CKDs and PCs can vary considerably, it is very difficult
to make conclusions on CKD-PC interaction based upon only one or two types of CKD
and one PC. The current study utilized seven CKDs with a wide range of composition
characteristics, two fillers, and two PCs. Within the range of materials and CKD and
filler replacement levels investigated in this study, the following main contributions
towards the performance of CKD-PC blends are:
1. CKD-PC blends can show comparable performance properties to PC alone and to
PC-filler blends. The components that govern the effects of CKDs as partial
replacement of PCs are: free lime, sulfates, chlorides, alkalis, calcium carbonate,
and fineness.
2. The most significant contribution to the optimization of CKD-PC blends is the
new premise that CKDs can contribute calcium and sulfate ions that are readily
available to control aluminate hydration. Many of the adverse effects of CKD-PC
blends are related to excessive amounts of calcium and sulfate ions. Therefore, if
249
CKD is used as partial PC replacement, optimum SO3 should be determined for
the CKD-PC blend and that would likely lead to lower gypsum additions.
3. The results of this study have been used to present the effects and relationships of
individual CKD-PC blend components using regression analysis techniques. The
effects and relationships based upon compositional analysis of the CKD-PC
blends are:
i. Water demand for pastes is higher for CKD-PC blends than for PC
alone. Very high and reactive amounts of free lime significantly increase
water demand. In the absence of high and reactive amounts of free lime,
the water demand of CKD-PC blends was similar or higher than the PC
alone.
ii. Mortar flow is generally lower for CKD-PC blends than for PC alone.
Very high and reactive amounts of free lime significantly increase water
demand. In the absence of high and reactive amounts of free lime, it
appears that the particle size distribution influences the flow. CKD-PC
blend flows decreased linearly as the percentage of particles passing 45
µm (Cement TI blends) and 30.5 (Cement TII blends) µm decreased.
iii. CKDs from preheater/precalciner kilns have high amounts of reactive
free lime that cause the impact of water demand and flow to be
significantly different in comparison to CKDs from wet and long-dry
kilns. Therefore, the preheater/precalciner kiln CKDs may need to be
categorized separately from wet and long-dry kiln CKDs.
250
iv. The presence of CKDs generally delays hydration of C3S in CKD-PC
blends. The data suggests the magnitude of this delay is linearly related
to the increased concentration of alkalis in the CKD-PC blends.
v. Since normal set is generally accepted to be a result of the onset of C3S
hydration, the presence of alkalis that delay C3S hydration will also
delay normal initial set. However, accelerated initial set may occur due
to the precipitation of hydration products that are not directly related to
C3S hydration (abnormal set). The likely precipitate products are AFt,
syngenite, calcium sulfate, and/or calcium hydroxide.
vi. CKDs influence the strength development of CKD-PC blends and tend
to have low early strengths and higher late age strengths. The increased
sulfate contents (beyond the PC optimum sulfate content) of the CKD-
PC blends reduced early age strengths. In the absence of high CKD
sulfate content, increased chloride content due to CKDs increased early
age strengths. For Cement TI (normal C3A), later age strengths were
adversely affected due to a lower percentage of particles passing the 45
µm sieve. For Cement TII (low C3A), the calcium carbonate fraction of
CKD performed as a diluent and resulted in lower later-age strengths.
vii. CKD-PC blends have higher expanions in limewater than PC alone.
Increased expansions in limewater of CKD-PC blends are linearly
related to increased concentrations of sulfate in the binder, likely due to
the formation of AFt in the hardened paste. It is believed that an
optimized sulfate content for a CKD-PC blend would mitigate these
expansions.
251
viii. CKD-PC blends have higher autoclave expansions than PC alone.
Increased autoclave expansions are related to high amounts of hard burnt
free lime content as opposed to total free lime content. It appears there
are also other contributing factors to autoclave expansion, such as the
presence of coarser particles in CKDs.
4. This study provides a contribution to the limited data that exists for the impact of
CKD-PC blends on ASR. It appears CKD-PC blends will result in higher ASR
expansion and that mitigative measures may have to be increased from those
currently recommended in CSA A23.2-27A.
252
6.0 CONCLUSIONS
Within the range of materials and CKD replacement levels investigated in this study, the
following conclusions are made.
1. CKD compositions vary with kiln process and the raw materials used. Therefore, the
impact of CKD as a partial replacement of PC may not be consistent. Further, a
particular CKD may impact CKD-PC blends differently due to varying compositions
in PC.
2. Thermal and compositional anaylsis methods used for PC must be modified to use on
CKDs by correcting for the volatile compounds that may be released during the LOI
test and fused bead preparation.
3. CKDs may contain significant amounts of amorphous material (>30%) and clinker
compounds (>20%) and small amounts of slag and/or fly ash (<5%) (if used as raw
materials in clinker production) and calcium langbeinite (<5%). Although these
materials/compounds do not necessarily govern the impact of CKD in a CKD-PC
blend, it is important to recognize they can have an influence on hydration and on the
compounds that are formed.
4. CKDs from preheater/precalciners have different effects on workability and heat
evolution than CKDs from the wet and long-dry kilns. The blends with the two CKDs
from preheater/precalciner plants had higher paste water demand, lower mortar flows,
and higher heat generation during initial hydrolysis in comparison to all other blends
and control cements. This is due to the high amounts of reactive free lime (>20%) in
CKDs from preheater/precalciner processes.
253
5. The effect of CKD as a partial replacement of PC appears to be governed by the
sulfate content of the CKD-PC blend (however, the form of the CKD sulfate is not
significant). According to the analysis of the ASTM C1038 expansion in limewater
test results in this study, the CKD-PC sulfate content should be less than ~0.40%
above the optimum sulfate content of the PC.
6. CKD in CKD-PC blends behaved similarly to the addition of gypsum to PC.
Therefore, CKD-PC blends could be optimized for sulfate content by using CKD as a
partial substitute of the gypsum during the grinding process to control the early
hydration of C3A. The wet and long-dry kiln CKDs contain significant amounts of
calcium carbonate (>20%) which could also be used as partial replacement of
limestone filler in PC. The impact of additional CKD components would need to be
considered.
7. With the knowledge gained in this thesis and other research studies, there may be
efforts directed towards modifying North American industry standards to allow for
appropriate utilization of CKDs as partial replacement of PC, between 5 and 10% by
mass. These changes would likely require less emphasis on the use of compositional
specifications and greater importance on the use of performance standards such as
ASTM C1157.
254
7.0 RECOMMENDATIONS FOR FUTURE WORK
1. The current study provides an understanding of the effect of free calcium and
sulfate ions from CKDs on C3S and C3A hydration in CKD-PC blends. Many of
the adverse effects of CKD-PC blends are related to excessive sulfate contents. It
would be useful to assess performance of the CKD-PC blends at optimum sulfate
content (as a partial substitute of gypsum).
2. The excessive contribution of free calcium and sulfate ions from CKDs appears to
dominate the behaviour of CKD-PC blends. Since gypsum (calcium sulfate) is
known to have a significant impact on drying shrinkage, this is another volume
stability parameter that should be investigated.
3. The two CKDs from preheater/precalciner plants performed significantly
differently in comparison to the CKDs from the wet and long-dry kilns with
respect to influence on water demand and flow. It would be beneficial to conduct
future studies with preheater/precalciner CKDs separate from wet and long-dry
kiln CKDs, particularly at PC replacement levels greater than 10%.
4. The current study utilized dry blending to mix the CKD-PC blends. Intergrinding
the CKD-PC blends, however, may produce different results. For example, it is
important to highlight the potential impact of highly reactive free lime to cause
gypsum false set if CKD from preheater/precalciners is interground with PC, as
opposed to being blended. Free lime, if too high and/or reactive, enhances
gypsum dehydration by its considerable hygroscopity (which allows it to extract
water from gypsum molecules during milling when they are in a state of
perturbation from the heat generated by frictional forces and liable to be subjected
to some decomposition) and also has the effect of delaying rehydration of
hemihydrate (Bensted, 1983b). This could enhance the likelihood of a plaster
255
(gypsum) false set. Therefore, the differences between intergrinding and blending
CKD-PC blends should be investigated.
5. The stirred suspension dissolution analyses of CKDs and PCs at w/b ratio of 10:1
were very useful to gain an understanding of rapid ion dissolution differences
between CKDs and PC during early age hydration. It would be interesting to
conduct further investigations of the actual CKD-PC blend pore solutions with
more practical w/b ratios, such as 0.4 to 0.7 at various ages. It is recommended
that the pore solution extractions be perfomed at very frequent periods during the
early stages of hydration. Geochemical software programming (i.e., PHREEQC)
could also be used to model and predict the hydration products at each stage.
6. The current study provides a hypothesis for the microstructural development of
CKD-PC blends during hydration based upon the effects and relationships among
the binder compositions and their performance in various physical tests. Further
work is needed to investigate the formation of hydration products as well as
morphology changes to C-S-H at various hydration ages.
7. The role of C3A is very important in CKD-PC blends. It would be interesting to
conduct studies on the reactions of C3A in the concomitant presence of calcium
sulfate, calcium chloride, and calcium carbonate. Each of these compounds is
known to react with C3A individually, but how they react together, as in CKDs, is
not yet clearly defined.
8. The hydration, mechanical properties, and durability effects of CKD-PC blends
with SCMs and/or chemical admixtures were not included in this study. This
needs to be investigated further.
256
9. The current study shows that CKDs contribute to deleterious ASR expansion
based upon the concrete prism tests. Measures to mitigate ASR expansion of
CKD-PC blends should be investigated, such as the addition of SCMs.
10. There are other durability concerns of CKD-PC blends, besides ASR. Elevated
concentrations of chlorides contribute to steel corrosion in concrete. Excessive
amounts of sulfate can contribute to internal sulfate attack. Higher alkali contents
can impact freezing and thawing resistance. Permeability may also be increased
due to the dilution of PC with CKDs. These durability concerns need to be
assessed.
257
8.0 REFERENCES
AASHTO M 85. Specification for Portland Cement. American Association of State and Highway Transportation Officials, Washington, DC. ACI 318. 2005. Building Code Requirements for Structural Concrete. American Concrete Institute, Farmington Hills, MI. Adaska, W. S., Tresouthick, S. W., and West, P. B. 1998. “Solidification and Stabilization of Waste Using Portland Cement”. Portland Cement Association, Research and Development EB071, Skokie, IL. Al-Harthy, A.S., Taha, R., Al-Maamary, F. 2003. “Effect of Cement Kiln Dust (CKD) on Mortar and Concrete Mixtures”. Construction and Building Materials, Vol. 17, No. 5, pp. 353-360. ASTM C39. 1999. Standard Test Method for Compressive Strength of Cylindrical
Concrete Specimens. American Society for Testing and Materials, Philadelphia, PA. ASTM C109. 1999. Standard Test Method for Compressive Strength of Hydraulic
Cement Mortars. American Society for Testing and Materials, Philadelphia, PA. ASTM C114. 2000. Standard Test Method for Chemical Analysis of Hydraulic Cement. American Society for Testing and Materials, Philadelphia, PA. ASTM C138. 1992. Standard Test Method for Unit Weight, Yield, and Air Content
(Gravimetric) of Concrete. American Society for Testing and Materials, Philadelphia, PA.
ASTM C143. 1998. Standard Test Method for Slump of Hydraulic-Cement Concrete. American Society for Testing and Materials, Philadelphia, PA.
ASTM C150. 2000. Standard Specification for Portland Cement. American Society for Testing and Materials, Philadelphia, PA. ASTM C151. 2000. Standard Test Method for Autoclave Expansion of Portland Cement. American Society for Testing and Materials, Philadelphia, PA. ASTM C157. 1999. Standard Test Method for Length Change of Hardened Hydraulic-
Cement Mortar and Concrete. American Society for Testing and Materials, Philadelphia, PA.
258
ASTM C186. 1998. Standard Test Method for Heat of Hydration of Hydraulic Cement. American Society for Testing and Materials, Philadelphia, PA. ASTM C187. 1998. Standard Test Method for Normal Consistency of Hydraulic Cement. American Society for Testing and Materials, Philadelphia, PA. ASTM C191. 1999. Standard Test Method for Time of Setting of Hydraulic Cement by
Vicat Needle. American Society for Testing and Materials, Philadelphia, PA. ASTM C204. 2000. Standard Test Method for Fineness of Hydraulic Cement by Air-
Permeability Apparatus. American Society for Testing and Materials, Philadelphia, PA. ASTM C227. 1997. Standard Test Method for Potential Alkali Reactivity of Cement-
Aggregate Combinations (Mortar-Bar Method). American Society for Testing and Materials, Philadelphia, PA.
ASTM C230. 1998. Standard Specification for Flow Table for Use in Tests of Hydraulic
Cement. American Society for Testing and Materials, Philadelphia, PA. ASTM C231. 1997. Standard Test Method for Air Content of Freshly Mixed Concrete by
the Pressure Method. American Society for Testing and Materials, Philadelphia, PA.
ASTM C430. 1996. Standard Test Method for Fineness of Hydraulic Cement by the 45-
µm (No. 325) Sieve. American Society for Testing and Materials, Philadelphia, PA. ASTM C451. 1999. Standard Test Method for Early Stiffening of Hydraulic Cement
(Paste Method). American Society for Testing and Materials, Philadelphia, PA. ASTM C465. 1999. Standard Specification for Processing Additions for Use in the
Manufacture of Hydraulic Cements. American Society for Testing and Materials, Philadelphia, PA. ASTM C666. 1997. Standard Test Method for Resistance of Concrete to Rapid Freezing
and Thawing. American Society for Testing and Materials, Philadelphia, PA. ASTM C876. 1991. Standard Test Method for Half-Cell Potentials of Uncoated
Reinforcing Steel in Concrete. American Society for Testing and Materials, Philadelphia, PA. ASTM C1012. 1995. Standard Test Method for Length Change of Hydraulic-Cement
Mortars Exposed to a Sulfate Solution. American Society for Testing and Materials, Philadelphia, PA.
259
ASTM C1038. 1995. Standard Test Method for Expansion of Hydraulic Cement Mortar
Bars Stored in Water. American Society for Testing and Materials, Philadelphia, PA. ASTM C1293. 2005. Standard Test Method for Determination of Length Change of
Concrete Due to Alkali-Silica Reaction. American Society for Testing and Materials, Philadelphia, PA. ASTM C1437. 2001. Standard Test Method for Flow of Hydraulic Cement Mortar. American Society for Testing and Materials, Philadelphia, PA. ASTM C1679. 2008. Standard Practice for Measuring Hydration Kinetics of Hydraulic
Cementitious Mixtures Using Isothermal Calorimetry1Test Method for Flow of Hydraulic
Cement Mortar. American Society for Testing and Materials, Philadelphia, PA. ASTM D5050. 1996. Standard Guide for Commercial Use of Lime Kiln Dusts and
Portland Cement Kiln Dusts. American Society for Testing and Materials, Philadelphia, PA. Babikan S.H. and Verville C. 2007. Internal Lafarge Testing Procedures. Lafarge Canada Inc., Montreal, Quebec. Barker, A.P. and Matthews J.D. 1989. “Heat release characteristics of limestone filled cements”. Performance of Limestone Filled Cements, Proc. Building Research Establishment Seminar, Garston, England, pp. 5.1-5.29. Batis, G., Katsiamboulas, A., Meletiou, C.A., and Chaniotakis, E. 1996. “Durability of Reinforced Concrete Made with Composite Cement Containing Cement Kiln Dust”. Concrete for Environment Enhancement and Protection: Proceedings of the
International Conference, Concrete in the Service of Mankind, R.K. Dhir and T.D. Dyer eds., University of Dundee, Dundee, United Kingdom, pp. 67-72. Bensted, J. 1980. “Some hydration investigations involving portland cement – Effect of calcium carbonate substitution of gypsum”. World Cement Technology, Vol. 11, No. 8, pp. 395-406. Bensted, J. 1983a. “Further hydration investigations involving portland cement and the substitution of limestone for gypsum”. World Cement Technology, Vol. 14, pp. 383-392. Bensted, J. 1983b, “Hydration of Portland Cement”. Advances in Cement Technology, Ghosh, S.N. (editor), Pergomon Press Ltd., Oxford, pp. 307-347. Bensted, J. 1987. “Some applications of conduction conduction calorimetry to cement hydration”. Advances in Cement Research, Vol. 1, No. 1, pp. 35-44.
260
Bentur, A. 1976. “Effect of Gypsum on the Hydration and Strength of C3S Pastes”. Journal of the American Ceramic Society, Vol. 59, No. 5-6, pp. 210-213. Bentz, D. P., Garboczi, E. J., Haecker, C. J., and Jensen, O.M. 1999. “Effects of cement particle size distribution on performance properties of Portland cement-based materials”. Cement and Concrete Research, Vol. 29, pp. 1663-1671. Bhattacharja, S. 1997. “Optimum Sulfate in Blended Cements”. Portland Cement
Association, Research and Development Serial No. 2057, Skokie, IL. Bhatty, M.S.Y. 1984. “Use of Cement Kiln Dust in Blended Cements”, World Cement, Vol. 15, No. 4, pp. 126-128, 131-134. Bhatty, M.S.Y. 1985a. “Kiln Dust Cement Blends Evaluated”. Rock Products, Vol. 88, No. 10, pp. 47-52, 65. Bhatty, M.S.Y. 1985b. “Use of Cement Kiln Dust in Blended Cements – Alkali-Aggregate Reactive Expansion”. World Cement, Vol. 16, No. 10, pp. 386, 388-390, 392. Bhatty, M.S.Y. 1986. “Properties of Blended Cements made with Portland Cement, Cement Kiln Dust, Flyash, and Slag”. Proceedings of the 8
th International Congress on
the Chemistry of Cement, Brazil, Vol. IV, pp. 118-127. Bhatty, J.I. 1995. “Alternative Uses of Cement Kiln Dust”. Portland Cement Association, Research and Development Bulletin RP327, Skokie, IL. Bhatty J.I. 2004. “Minor Elements in Cement Manufacturing”. Innovations in Portland
Cement Manufacturing, Bhatty J. I., Miller, F. M., and Kosmatka, S.H. (editors), Portland Cement Association, 5420 Old Orchard Road, Skokie, IL 60077, pp. 403-452. Bhatty J.I. and Gajda J. 2004. “Use of Alternative Materials in Cement Manufacturing”. Innovations in Portland Cement Manufacturing, Bhatty J. I., Miller, F. M., and Kosmatka, S.H. (editors), Portland Cement Association, 5420 Old Orchard Road, Skokie, IL 60077, pp. 137-166. Brookbanks, P. 1989. “Properties of fresh concrete”. Performance of Limestone Filled
Cements, Proc. Building Research Establishment Seminar, Garston, England, pp. 4.1-4.15.
Brown, P.W., Liberman, L.O., and Frohnsdorff, G. 1984. “Kinetics of the Early Hydration of Tricalcium Aluminate in Solutions Containing Calcium Sulfate”. Journal of
the American Ceramic Society, Vol. 67, No. 12, pp. 793-795. Bye, G.C. 1999. “Portland Cement”, Second Edition, Thomas Telford, London, U.K.
261
CSA A3001. 2008. Cementitious materials for use in concrete. Canadian Standards Association, Toronto Canada. CSA A23.2-14A. 2004. Potential Expansivity of Aggregates; Procedure for Length
Change Due to Alkali-Aggregate Reaction in Concrete Prisms at 38°C. Canadian Standards Association, Toronto, Canada. CSA A23.2-27A. 2004. Standard Practice to Identify Potential for Alkali-Reactivity of
Aggregates and Measures to Avoid Deleterious Expansion in Concrete. Canadian Standards Association, Toronto, Canada. CSA A456.2-C3. 1998. Test Method for Determination of Compressive Strengths.
Canadian Standards Association, Toronto, Canada. Chatterjee A.K. 2004. “Materials Preparation and Raw Milling”. Innovations in Portland
Cement Manufacturing, Bhatty J. I., Miller, F. M., and Kosmatka, S.H. (editors), Portland Cement Association, 5420 Old Orchard Road, Skokie, IL 60077, pp. 81-136. Cochet, G. and Sorrentino, F. 1993. “Limestone filled cements: properties and uses”. Mineral Admixtures in Cement and Concrete, Ghosh, S.N., Sarkar, S.L., and Harsh, S. (editors), ABI Book Pvt. Ltd., New Delhi, India, Vol. 4, pp. 266-295.
Collepardi, M., Baldini, G., and Pauri, M. 1978. “Tricalcium Aluminate Hydration in the Presence of Lime, Gypsum or Sodium Sulfate”. Cement and Concrete Research, Vol. 8, pp. 571-580. Collins, R.J. and Emery, J.J. 1983. “Kiln Dust-Fly Ash System for Highway Bases and Subbases”. Federal Highway Administration Report FHWA/RD-82/167, U.S Department of Transportation, Washington D.C. Corish A. and Coleman, T. 1995. “Cement kiln dust”, Concrete, Vol. 29, No. 5, pp. 40–42. Damidot D. and Nonat A. 1992. “A method for determining the advancement of the hydration of C3S in diluted suspensions by means of simultaneous conductimetric and calcorimetric measurements”. Proceedings of the 9
th International Congress on the
Chemistry of Cement, New Delhi, Vol. III, pp. 227-236.
Damidot, D. and Glasser, F.P. 1995. “Investigation of the CaO–Al2O3–SiO2–H2O system at 25 °C by thermodynamic calculations”. Cement Concrete Research, Vol. 25, No. 1, pp. 22–28.
262
Detwiler, R.J, Bhatty, J.I., and Bhattacharja, S. 1996. “Supplementary Cementing Materials for use in Blended Cements”. Research and Development Bulletin RD112T, Portland Cement Association, Skokie, IL. Dodson V. 1990. “Concrete Admixtures”. Van Nostrand Reinhold. Pg 23 Dyer, T.D., Halliday, J.E., and Dhir, R.K. 1999. “An Investigation of the Hydration Chemistry of Ternary Blends Containing Cement Kiln Dust”. Journal of Materials
Science, Vol. 34, No. 20, pp. 4975-4983. El-Aleem, S.A., Abd-El-Aziz, M.A., Heikal, M., and El-Didamony, H. 2005. “Effect of Cement Kiln Dust Substitution on Chemical and Physical Properties and Compressive Strength of Portland and Slag Cements”. The Arabian Journal for Science and
Engineering, Volume 30, Number 2B, Saudi Arabia, pp. 263-273. El-Sayed, H.A., Gabr, N.A., Hanafi, S., and Mohran, M.A. 1991. “Re-utilization of by-pass kiln dust in cement manufacture”. International Conference on Blended Cement in
Construction, Sheffield, United Kingdom, pp. 84-94. EPA. 1993. “Report to Congress on Cement Kiln Dust”. U.S. Environmental Protection
Agency, Office of Solid Waste and Emergency Response, EPA-530-R-94-001.
EN 196-1. 1987. Methods of testing cement. Determination of strength. European Standard. EN 196-3. 2005. Methods of testing cement. Determination of setting time and soundness. European Standard. EN 197-1. 2000. Cement. Composition, specifications and conformity criteria for
common cements. European Standard. Frigione, G. 1983. “Gypsum in Cement”. Advances in Cement Technology, Ghosh, S.N. (editor), Pergomon Press Ltd., Oxford, pp. 485-536. Gartner, E.M., Young, J.F., Damidot, D.A., and Jawed, I. 2002. “Hydration of Portland Cement”. Structure and Performance of Cement, Second Edition, Bensted, J. and Barnes, P. (editors), Spon Press, New York, pp. 57-114. Greco C., Picciotti G., Greco R.B., and Ferreira G.M. 2004. “Fuel Selection and Use”. Innovations in Portland Cement Manufacturing, Bhatty J. I., Miller, F. M., and Kosmatka, S.H. (editors), Portland Cement Association, 5420 Old Orchard Road, Skokie, IL 60077, pp. 167-238.
263
Greening, N.R. 1967. “Some Causes for Variation in Required Amount of Air-Entraining Agent in Portland Cement Mortars” Portland Cement Association, Research and Development Bulletin RX213, Skokie, IL.
Hawkins, G.J., Bhatty, J. I., and O’Hare, A.T. 2004. “Cement Kiln Dust Generation and Management”. Innovations in Portland Cement Manufacturing, Bhatty J. I., Miller, F. M., and Kosmatka, S.H. (editors), Portland Cement Association, 5420 Old Orchard Road, Skokie, IL 60077, pp. 735-779. Hawkins, P., Tennis, P., and Detwiler, R.J. 2005. “The Use of Limestone in Portland Cement: A State of the Art Review”. Portland Cement Association, Research & Development Serial No. 2052b, Skokie, IL. Haynes, B.W. and Kramer G.W. 1982. “Characterization of U.S. cement kiln dust”. U.S.
Department of the Interior, Bureau of Mines Information Circular 8885, Pittsburgh, PA. Helmuth, R. 1987. “Fly Ash in Cement and Concrete”. Portland Cement Association, Skokie, IL. Hooton, R.D. 1990. “Effects of carbonate additions on heat of hydration and sulfate resistance”, Carbonate Additions to Cement, Klieger P. and Hooton, R.D. (editors), ASTM STP 1064, American Society for Testing and Materials, Philadelphia, PA, pp. 73-81. Hooton, R.D. and Thomas, M.D.A., 2002. “The Use of Limestone in Portland Cements: Effect on Thaumasite Form of Sulfate Attack”. Portland Cement Association, Research and Development Serial No. 2658, Skokie, IL.
Ish-Shalom, M. and Bentur, A. 1972. “Effects of Aluminate and Sulfate Contents on the Hydration and Strength of Portland Cement Pastes and Mortars”. Cement and Concrete
Research, Vol. 2, pp. 653-662. Jackson, P.J. 1998. “Portland Cement: Classification and Manufacture”. Lea’s Chemistry
of Cement and Concrete, Hewlett, P.C. (editor), John Wiley & Sons Inc., New York, pp. 25-94. Juenger, M.C.G., Monteiro, P.J.M., Gartner, E.M., and Denbeaux, G.P. 2005. “A soft X-ray microscope investigation into the effects of calcium chloride on tricalcium silicate hydration”. Cement and Concrete Research, Vol. 35, pp. 19-25.
Kessler, G.R. 1995. “Cement Kiln Dust (CKD) Methods for Reduction and Control”. IEEE Transaction on Industry Applications, Vol. 31, No. 2, pp.407-412.
264
Konsta-Gdoutos, M.S., Wang, K., Babaian, P.M., M.S., and Shah, S.P. 2001. “Effect of Cement Kiln Dust (CKD) on the Corrosion of Reinforcement in Concrete”. Third
International Conference on Concrete Under Service Conditions of Environment and
Loading (CONSEC ’01), Banthia N., Saloi, K., and Gjorv, O.E. (editors), Vancouver, British Columbia, Canada, pp. 277-284. Konsta-Gdoutos, M.S., and Shah, S.P. 2003. “Cement Kiln Dust (CKD): Characterization and Utilization in Cement and Concrete”. Celebrating Concrete: People and Practice, in
Role of Cement Science in Sustainable Development, Dhir, R.V., Newlands, M.D., and Csetenvi, L.J. (editors), pp. 59-70. Klemm, W.A. 1980. “Kiln Dust Utilization”. Martin Marietta Laboratories Report, MML TR 80-12. Baltimore, MD.
Klemm, W.A. 2005. “Cement Soundness and the Autoclave Expansion Test – An Update of the Literature”. Portland Cement Association, Research & Development Serial No. 2651, Skokie, IL.
Klemm, W.A. and Adams, L.D. 1990. “An investigation of the formation of carboaluminates”. Carbonate Additions to Cement, Klieger P. and Hooton, R.D. (editors), ASTM STP 1064, American Society for Testing and Materials, Philadelphia, PA, pp. 60–72.
Lachemi, M., Hossain, K.M.A., Shehata, M., and Thaha, W. 2008. “Controlled low strength materials incorporating cement kiln dust”. Cement & Concrete Composites, Vol. 30, No. 5, pp. 381-392. Lafarge. 2005. Lafarge Canada Inc., Internal Laboratory Report, Montreal, QC. Lafarge. 2009. Lafarge Canada Inc., Internal Laboratory Data, Montreal, QC. Lawrence, C.D. 1998a. “The Constitution and Specification of Portland Cements”. Lea’s
Chemistry of Cement and Concrete, Hewlett, P.C. (editor), John Wiley & Sons Inc., New York, pp. 131-194. Lawrence, C.D. 1998b. “Physiochemical and Mechanical Properties of Portland Cements”. Lea’s Chemistry of Cement and Concrete, Hewlett, P.C. (editor), John Wiley & Sons Inc., New York, pp. 343-420. Lehoux, P. 2006. Lafarge Canada Inc., Personal Communication, Received by O.S. Khanna. Lerch, W. 1944. “The effects of added materials on the rate of hydration of Portland Cement pastes at early ages”. Portland Cement Association, Skokie, IL.
265
Manias, G.C., 2004. “Kiln Burning Systems”. Innovations in Portland Cement
Manufacturing, Bhatty J. I., Miller, F. M., and Kosmatka, S.H. (editors), Portland Cement Association, 5420 Old Orchard Road, Skokie, IL 60077, pp. 239-268. Maslehuddin, M., Al-Amoudib, O.S.B., Shameema, M., Rehmana, M.K., and Ibrahim, M. 2008a. “Usage of cement kiln dust in cement products – Research review and preliminary investigations”. Construction and Building Materials, Vol. 22, Issue 12, pp. 2369-2375. Maslehuddin, M., Al-Amoudia, O.S.B., Rahmana, M.K., Alia, M.R., and Barrya, M.S. 2008b. “Properties of cement kiln dust concrete”. Construction and Building Materials, Vol. 23, Issue 6, pp. 2357-2361. Mattus, C.H. and Gilliam, T.M. 1994. “A Literature Review of Mixed Waste Components: Sensitivities and Effects upon Solidification/Stabilization in Cement-Based Matrices”. ORNL/TM-12656, Oak Ridge National Laboratory, Oak Ridge, TN, USA. Mostafa, N.Y., and Brown, P.W. 2005. “Heat of hydration of high reactive pozzolans in blended cements: Isothermal conduction conduction calorimetry”. Thermochimica Acta, Vol. 435, No.2, pp. 162–167.
Muller, H.P. 1977. “What is Dust? Characterization and Classification of Kiln Dust”, Holderbank Management and Consulting, Technical Center, Material Division, Aargau, Switzerland, Report No. MA 77/2505/E. Narang, K. C.; Ghosh, S. K.; Sharma, K. M. 1981. “Microstructural Characteristics of Sound and Unsound Clinkers with Varying MgO Content”. Proceedings of the Third
Annual International Conference On Cement Microscopy, Houston, Texas, pp. 140-153
Neville, A. M. 1996. “Properties of Concrete: Fourth and Final Edition”. John Wiley & Sons Inc. Nonat, A. 1994. “Interactions between chemical evolution (hydration) and physical evolution (setting) in the case of tricalcium silicate”. Materials and Structures, Vol. 27, pp. 187-195. Odler, I. 1998. “Hydration, Setting and Hardening of Portland Cement”. Lea’s Chemistry
of Cement and Concrete, Hewlett, P.C. (editor), John Wiley & Sons Inc., New York, pp. 241-298. Osbaeck, B. and Jons, E.S. 1980. “The Influence of the Content and Distribution ofAlkalies on the Hydration Properties of Portland Cement”. 7th International Congress on the Chemistry of Cement, Paris. Vol. 2, pp. 135-140.
266
Pera, J., Husson, S., and Guilhot, B.1999. “Influenec of finely ground limestone on cement hydration”. Cement and Concrete Composites, Vol. 21, pp. 99-105. Peethamparan, S. 2006. “Fundamental study of clay-cement kiln dust (CKD) interaction to determine the effectiveness of CKD as a potential clay soil stabilizer”. Ph.D.Thesis, Purdue University. Peethamparan, S., Olek, J., and Lovell, J. 2008. “Influnce of chemical and physical characteristics of cement kiln dusts (CKDs) on their hydration behaviour and potential suitability for soil stabilization”. Cement and Concrete Research, Vol. 38, pp. 803-815. Peray, K.E. 1986. “The Rotary Cement Kiln - 2nd Edition”. Chemical Publishing Company. Ramachandran, V.S. and Zhang, C. 1986. “Thermal analysis of the 3CaO.Al2O3---CaSO4.2H2O---CaCO3.H2O system”. Thermochima Acta, Vol. 106, pp. 273–282.
Ramachandran, V.S. 1988. “Thermal analysis of cement components hydrated in the presence of calcium carbonate”. Thermochima Acta, Vol. 127, pp. 385-94. Ramakrishnan, V. 1986. “Evaluation of Kiln Dust in Concrete, Flyash, Silica Fume, Slag, and Natural Pozzolans in Concrete”. American Concrete Institute, SP-91, pp. 821-839. Ramakrishnan, V., and Balaguru, P. 1987. “Durability of Concrete Containing Cement Kiln Dust”. American Concrete Institute - Concrete Durability: Katherine and Bryant
Mather International Conference, SP100-19, Vol. 1, pp. 305-321. Ravindrarajah, R.S. 1982. “Usage of cement kiln dust in concrete”. The International
Journal of Cement Composites and Lightmass Concrete, Vol. 4, No. 2, pp. 95-102. Roy, D.M. and Malek, R.I.A. 1993. “Hydration of Slag Cement”. Mineral Admixtures in
Cement and Concrete, Sarkar, S.L. and Ghosh, S.N. (editors), ABI Books Pvt. Ltd., New Delhi, pp. 84–117. Sandberg, P.J. and Roberts, L.R. 2005. “Cement-admixture interactions related to aluminate control”. 2005. Journal of ASTM International, Vol. 2, No. 6, pp. 219-232 Shi, H., Zhao, Y., and Li, W. 2002. “Effects of temperature on the hydration characteristics of free lime”. Cement and Concrete Research, Vol. 32, pp. 789-793. Shoaib, M.M., Balaha, M.M., and Abdel-Rahman, A.G. 2000. “Influence of cement kiln dust substitution on the mechanical properties of concrete”. Cement and Concrete
Research, Vol. 30, No. 2, pp. 371-377.
267
Sengun, M.Z. and Probstein, R.F. 1997. “Bimodal model of suspension viscoelasticity”. Journal of Rheology, Vol. 41, No.4, pp. 811-819. Soroka, I. 1979. “Portland Cement Paste & Concrete”. The MacMillan Press Ltd. Soroka I. and Relis M. 1983. “Effect of Added Gypsum on Compressive Strength of Portland Cement Clinker.” American Ceramic Society Bulletin, Vol. 62, No. 6, pp. 695-697. Sprung, S., Kuhlmann, K., and Ellerbrock, H.G. 1985. “Particle Size Distribution and Properties of Cement: Part II. Water Demand of Portland Cement”. Zement-Kalk-Gips,
Vol. 38, No. 9, pp. 528-534. Sprung, S. and Siebel, E. 1991. “Assessment of the suitability of limestone for producing portland limestone cement”. Zement-Kalk-Gips, Vol. 44, No. 1, pp. 1-11. Sreekrishnavilasam, A., King, S., and Santagata, M. 2006. “Characterization of fresh and landfilled cement kiln dust for reuse in construction applications”. Engineering Geology, Volume 85, Issues 1-2, pp. 165-173. Tang F.J., and Gartner, E.M. 1988. “Influence of sulphate source on Portland cement hydration”. Advances in Cement Research, Vol. 1, No. 2, pp. 67-74. Taylor, H. F. W. 1997. “Cement Chemistry - 2nd Edition”. Thomas Telford. Tennis P. and Bhatty J.I. 2006. “Characteristics of portland and blended cements: results of a survey of manufacturers”. Cement Industry Technical Conference, Conference
Record, IEEE, ISBN: 1-4244-0372-3, pp. 83-101.
Tennis P. and Kosmatka, S.H. 2004. “Cement Characteristics”. Innovations in Portland
Cement Manufacturing, Bhatty J. I., Miller, F. M., and Kosmatka, S.H. (editors), Portland Cement Association, 5420 Old Orchard Road, Skokie, IL 60077, pp. 1069-1106. Udoeyo F.F., and Hyee, A. 2002. “Strengths of Cement Kiln Dust Concrete”. Journal of
Materials in Civil Engineering, Vol. 14, Issue 6, pp. 524-526. Vernet, C. and Noworyta, G. 1992. “Mechanisms of limestone reactions in the system C3A-CaSO4.H2O-CH-CaCO3-H”. 9th
International Congress on Chemistry of Cement, New Delhi, Vol. IV, pp. 430-436.
Vuk, T., Tinta, V., Babrovsek, R., and Kaucic, V. 2001. “The Effects of Limestone Addition on, Clinker Type, and Fineness on Prperties of Portland Cement”. Cement and
Concrete Research, Vol. 31, No. 1, pp. 481-489.
268
Wang, K., Konsta-Gdoutos, M.S., and Shah, S.P. 2002. “Hydration, Rheology, and Strength of Ordinary Portland (OPC)-Cement Kiln Dust (CKD)-Slag Binders”. American
Concrete Institute Materials Journal, Vol. 99, No. 2, pp. 173-170. Wang, M.L., and Ramakrishnan, V. 1990. “Evaluation of Blended Cement, Mortar and Concrete made from Type III Cement and Kiln Dust”. Construction and Building
Materials, Vol. 4, No. 2, pp. 78-85.
269
Appendix A. CKD Chemical Composition Correction Calculations
270
271
Appendix B. PC and CKD TGA Analysis
272
Cement TI
Cement TII
273
CKD A
CKD B
274
CKD C
CKD D*
275
CKD D
CKD E
276
CKD F
277
Appendix C. CKD XRD Scans
278
C
KD
A
279
C
KD
B
280
C
KD
C
281
C
KD
D*
282
C
KD
D
283
C
KD
E
284
C
KD
F
285
Appendix D. PC, CKD-PC, and PC-Filler Properties
286
Table D.1 Chemical and Physical Composition of
TI Blends with 10% Replacement
Components TI TI CKD A
10% TI CKD B
10% TI CKD C
10% TI CKD D
10% TI CKD E
10% TI CKD F
10% TI CKD LS 10%
TI CKD SLX 10%
SiO2 19.15 18.66 19.65 18.67 18.68 18.76 18.92 17.50 27.05
Al2O3 5.83 5.62 6.16 5.65 5.74 5.63 5.64 5.32 5.29
Fe2O3 2.46 2.40 2.59 2.37 2.43 2.44 2.40 2.23 2.22
CaO 62.03 60.26 59.10 60.30 60.38 61.35 61.41 61.18 55.83
MgO 2.18 2.14 2.15 2.07 2.13 2.25 2.27 2.02 1.96
SO3 4.35 4.22 4.49 4.65 5.53 5.09 4.81 3.92 3.92
Na2O 0.30 0.33 0.32 0.29 0.34 0.30 0.30 0.27 0.27
K2O 1.01 1.25 1.39 1.23 1.36 1.39 1.28 0.93 0.92
Na2Oe 0.97 1.15 1.24 1.10 1.23 1.21 1.14 0.89 0.88
Sol. Na2O 0.16 0.18 0.17 0.15 0.18 0.16 0.16 0.14 0.14
Sol. K2O 0.97 1.14 1.26 1.07 1.16 1.26 1.11 0.87 0.87
Sol. Na2Oe 0.80 0.93 1.00 0.86 0.95 0.99 0.89 0.72 0.72
TiO2 0.25 0.26 0.28 0.25 0.25 0.25 0.24 0.23 0.23
P2O5 0.26 0.24 0.24 0.24 0.25 0.24 0.24 0.23 0.23
Mn2O3 0.09 0.09 0.09 0.08 0.09 0.13 0.09 0.08 0.08
Cl 0.00 0.25 0.09 0.04 0.03 0.22 0.08 0.00 0.00
LOI 1.79 4.48 3.39 3.98 2.60 2.19 2.15 5.84 1.63
pH* 11.90 11.92 11.92 11.94 11.95 11.99 11.99 11.66 11.31
Ca(OH)2 0.40 0.36 0.36 0.36 0.36 0.46 0.85 0.36 0.36
fCaO 0.40 0.81 0.76 0.93 1.42 3.20 3.81 0.36 0.36
Relative Density 3.11 3.08 3.07 3.08 3.09 3.10 3.08 3.07 3.07
Blaine (m2/kg) 367 396 399 398 391 365 383 379 394
45µm, % passing 95.74 93.50 92.48 93.28 94.89 93.07 93.66 96.12 95.98
Na2Oe: Na2O + 0.658 (K2O) LOI: Loss on ignition * based on w/b = 10 solution analysis @ 10 minutes fCaO: free lime
287
Table D.2 Chemical and Physical Composition of
TI Blends with 20% Replacement
Components TI TI CKD A
20% TI CKD B
20% TI CKD C
20% TI CKD D
20% TI CKD E
20% TI CKD F
20% TI CKD LS 20%
TI CKD SLX 20%
SiO2 19.15 18.17 20.14 18.18 18.21 18.37 18.68 15.84 34.95
Al2O3 5.83 5.42 6.49 5.47 5.65 5.42 5.45 4.80 4.76
Fe2O3 2.46 2.35 2.72 2.28 2.40 2.42 2.35 2.01 1.98
CaO 62.03 58.49 56.16 58.57 58.73 60.66 60.80 60.32 49.63
MgO 2.18 2.11 2.11 1.95 2.08 2.32 2.36 1.86 1.75
SO3 4.35 4.09 4.64 4.94 6.71 5.83 5.27 3.49 3.49
Na2O 0.30 0.36 0.35 0.28 0.37 0.29 0.30 0.24 0.24
K2O 1.01 1.48 1.77 1.45 1.70 1.78 1.54 0.85 0.83
Na2Oe 0.97 1.33 1.51 1.23 1.49 1.46 1.32 0.80 0.79
Sol. Na2O 0.16 0.20 0.19 0.15 0.21 0.16 0.16 0.13 0.13
Sol. K2O 0.97 1.31 1.55 1.17 1.35 1.56 1.26 0.77 0.77
Sol. Na2Oe 0.80 1.06 1.21 0.92 1.10 1.19 0.98 0.64 0.64
TiO2 0.25 0.28 0.31 0.24 0.25 0.25 0.24 0.21 0.21
P2O5 0.26 0.23 0.23 0.21 0.24 0.23 0.22 0.21 0.21
Mn2O3 0.09 0.08 0.08 0.08 0.09 0.17 0.08 0.07 0.07
Cl 0.00 0.50 0.19 0.08 0.07 0.44 0.17 0.00 0.00
LOI 1.79 7.18 5.00 6.18 3.42 2.60 2.52 9.89 1.47
pH* 11.90 11.94 11.95 11.98 12.00 12.09 12.09 11.42 10.72
Ca(OH)2 0.40 0.32 0.32 0.32 0.32 0.52 1.30 0.32 0.32
fCaO 0.40 1.22 1.13 1.46 2.44 6.01 7.22 0.32 0.32
Relative Density 3.11 3.04 3.02 3.04 3.06 3.08 3.05 3.03 3.02
Blaine (m2/kg) 367.00 424 430 430 416 364 399 391 421
45µm, % passing 95.74 91.25 89.21 90.81 94.04 90.39 91.57 96.50 96.21
Na2Oe: Na2O + 0.658 (K2O) LOI: Loss on ignition * based on w/b = 10 solution analysis @ 10 minutes fCaO: free lime
288
Table D.3 Chemical and Physical Composition of
TII Blends with 10% Replacement
DESCRIPTION TII TII CKD A 10%
TII CKD B 10%
TII CKD C 10%
TII CKD D 10%
TII CKD E 10%
TII CKD F 10%
TII CKD LS 10%
TII CKD SLX 10%
SiO2 20.39 19.77 20.75 19.78 19.79 19.87 20.03 18.61 28.16
Al2O3 4.21 4.16 4.70 4.19 4.28 4.16 4.18 3.85 3.83
Fe2O3 3.01 2.90 3.08 2.86 2.92 2.93 2.90 2.73 2.71
CaO 63.06 61.18 60.02 61.23 61.30 62.27 62.34 62.10 56.75
MgO 3.21 3.07 3.07 2.99 3.06 3.18 3.20 2.95 2.89
SO3 2.98 2.98 3.26 3.41 4.30 3.86 3.58 2.68 2.68
Na2O 0.13 0.18 0.17 0.14 0.18 0.14 0.15 0.12 0.12
K2O 0.69 0.95 1.10 0.94 1.06 1.10 0.98 0.64 0.62
Na2Oe 0.58 0.80 0.89 0.75 0.88 0.87 0.80 0.54 0.53
Sol. Na2O 0.06 0.09 0.09 0.07 0.10 0.07 0.07 0.06 0.06
Sol. K2O 0.64 0.84 0.97 0.78 0.87 0.97 0.82 0.58 0.58
Sol. Na2Oe 0.49 0.65 0.72 0.58 0.67 0.71 0.61 0.44 0.44
TiO2 0.26 0.27 0.29 0.25 0.26 0.26 0.25 0.24 0.24
P2O5 0.12 0.12 0.12 0.11 0.12 0.12 0.12 0.11 0.11
Mn2O3 0.56 0.51 0.51 0.51 0.51 0.55 0.51 0.50 0.50
Cl 0.00 0.25 0.09 0.04 0.03 0.22 0.08 0.00 0.00
LOI 1.28 4.02 2.93 3.52 2.14 1.74 1.70 5.38 1.17
pH* 11.90 11.92 11.92 11.94 11.95 11.99 11.99 11.66 11.31
Ca(OH)2 1.30 1.17 1.17 1.17 1.17 1.27 1.66 1.17 1.17
fCaO 0.55 0.94 0.90 1.06 1.55 3.34 3.94 0.49 0.49
Relative Density 3.18 3.14 3.13 3.14 3.15 3.16 3.14 3.13 3.13
Blaine (m2/kg) 377 405 408 407 400 374 392 388 403
45µm, % passing 92.01 90.14 89.12 89.92 91.53 89.71 90.30 92.76 92.62
Na2Oe: Na2O + 0.658 (K2O) LOI: Loss on ignition * based on w/b = 10 solution analysis @ 10 minutes fCaO: free lime
289
Table D.4 Chemical and Physical Composition of
TII Blends with 20% Replacement
DESCRIPTION TII TII CKD A 20%
TII CKD B 20%
TII CKD C 20%
TII CKD D 20%
TII CKD E 20%
TII CKD F 20%
TII CKD LS 20%
TII CKD SLX 20%
SiO2 20.39 19.16 21.12 19.17 19.19 19.36 19.67 16.83 35.94
Al2O3 4.21 4.12 5.19 4.17 4.35 4.12 4.15 3.50 3.46
Fe2O3 3.01 2.79 3.16 2.72 2.84 2.86 2.79 2.45 2.42
CaO 63.06 59.31 56.99 59.40 59.55 61.48 61.62 61.14 50.45
MgO 3.21 2.93 2.93 2.77 2.91 3.14 3.19 2.68 2.57
SO3 2.98 2.99 3.54 3.84 5.61 4.73 4.18 2.39 2.39
Na2O 0.13 0.22 0.21 0.14 0.24 0.16 0.17 0.11 0.11
K2O 0.69 1.22 1.51 1.19 1.44 1.51 1.28 0.59 0.56
Na2Oe 0.58 1.02 1.20 0.92 1.18 1.15 1.01 0.50 0.48
Sol. Na2O 0.06 0.13 0.11 0.07 0.13 0.08 0.08 0.05 0.05
Sol. K2O 0.64 1.05 1.29 0.91 1.09 1.30 1.00 0.51 0.51
Sol. Na2Oe 0.49 0.81 0.96 0.67 0.85 0.94 0.73 0.39 0.39
TiO2 0.26 0.29 0.32 0.25 0.26 0.26 0.25 0.21 0.21
P2O5 0.12 0.12 0.12 0.10 0.13 0.12 0.11 0.10 0.10
Mn2O3 0.56 0.46 0.46 0.46 0.46 0.55 0.46 0.45 0.45
Cl 0.00 0.50 0.19 0.08 0.07 0.44 0.17 0.00 0.00
LOI 1.28 6.77 4.59 5.77 3.01 2.20 2.12 9.48 1.06
pH* 11.90 11.94 11.95 11.98 12.00 12.09 12.09 11.42 10.72
Ca(OH)2 1.30 1.04 1.04 1.04 1.04 1.24 2.02 1.04 1.04
fCaO 0.55 1.34 1.24 1.58 2.55 6.13 7.34 0.44 0.44
Relative Density 3.18 3.09 3.07 3.10 3.12 3.14 3.11 3.09 3.08
Blaine (m2/kg) 377 432 438 438 424 372 407 399 429
45µm, % passing 92.01 88.27 86.23 87.83 91.05 87.41 88.59 93.52 93.23
Na2Oe: Na2O + 0.658 (K2O) LOI: Loss on ignition * based on w/b = 10 solution analysis @ 10 minutes fCaO: free lime
290
Table D.5 Mineralogical Composition of TI Blends with 10% Replacement
Components TI TI CKD A
10% TI CKD B
10% TI CKD C
10% TI CKD D
10% TI CKD E
10% TI CKD F
10% TI CKD LS 10%
TI CKD SLX 10%
Alite 68.60 61.86 61.74 61.84 61.89 61.92 61.83 61.74 61.74
ß-Belite 10.30 11.46 10.04 10.32 9.87 10.62 9.66 9.27 9.27
Aluminate 8.70 7.88 7.88 7.90 7.88 7.97 7.88 7.83 7.83
Brownmillerite 7.50 6.77 6.81 6.81 6.75 6.99 6.80 6.75 6.75
Gypsum 1.70 1.53 1.53 1.53 1.53 1.53 1.53 1.53 1.53
Hemihydrate 0.50 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45
Calcite 0.70 5.89 4.10 5.76 2.90 0.75 1.05 10.43 0.82
Quartz 0.30 1.19 0.99 1.35 0.59 0.92 0.87 0.47 10.09
Dolomite 0.00 0.45 0.31 0.00 0.10 0.00 0.00 0.00 0.00
Periclase 1.40 1.32 1.33 1.27 1.29 1.47 1.45 1.26 1.26
Lime 0.00 0.37 0.33 0.50 1.18 2.84 3.45 0.00 0.00
Portlandite 0.10 0.09 0.11 0.09 0.09 0.20 0.41 0.09 0.09
Anhydrite 0.20 0.37 0.41 0.66 1.98 1.56 0.73 0.18 0.18
Calcium Langbeinite 0.00 0.00 0.00 0.16 0.26 0.11 0.14 0.00 0.00
Aphthitalite 0.00 0.00 0.07 0.00 0.17 0.00 0.00 0.00 0.00
Arcanite 0.00 0.00 0.16 0.09 0.00 0.06 0.06 0.00 0.00
Calcium Sulfoaluminate 0.00 0.00 0.00 0.09 0.06 0.14 0.06 0.00 0.00
Sylvite 0.00 0.32 0.11 0.03 0.02 0.39 0.04 0.00 0.00
Calcium Chloride 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00
Amorphous 0.00 0.05 3.21 1.11 2.93 1.83 3.50 0.00 0.00
Akermanite 0.00 0.00 0.00 0.00 0.00 0.11 0.00 0.00 0.00
Calcium Dialuminium Oxide 0.00 0.00 0.00 0.00 0.04 0.14 0.10 0.00 0.00
Mullite 0.00 0.00 0.41 0.00 0.00 0.00 0.00 0.00 0.00
291
Table D.6 Mineralogical Composition of TI Blends with 20% Replacement
Components TI TI CKD A
20% TI CKD B
20% TI CKD C
20% TI CKD D
20% TI CKD E
20% TI CKD F
20% TI CKD LS 20%
TI CKD SLX 20%
Alite 68.60 55.12 54.88 55.08 55.18 55.24 55.06 54.88 54.88
ß-Belite 10.30 12.62 9.78 10.34 9.44 10.94 9.02 8.24 8.24
Aluminate 8.70 7.06 7.06 7.10 7.06 7.24 7.06 6.96 6.96
Brownmillerite 7.50 6.04 6.12 6.12 6.00 6.48 6.10 6.00 6.00
Gypsum 1.70 1.36 1.36 1.36 1.36 1.36 1.36 1.36 1.36
Hemihydrate 0.50 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40
Calcite 0.70 11.08 7.50 10.82 5.10 0.80 1.40 20.16 0.93
Quartz 0.30 2.08 1.68 2.40 0.88 1.54 1.44 0.64 19.87
Dolomite 0.00 0.90 0.62 0.00 0.20 0.00 0.00 0.00 0.00
Periclase 1.40 1.24 1.26 1.14 1.18 1.54 1.50 1.12 1.12
Lime 0.00 0.74 0.66 1.00 2.36 5.68 6.90 0.00 0.00
Portlandite 0.10 0.08 0.12 0.08 0.08 0.30 0.72 0.08 0.08
Anhydrite 0.20 0.54 0.62 1.12 3.76 2.92 1.26 0.16 0.16
Calcium Langbeinite 0.00 0.00 0.00 0.32 0.52 0.22 0.28 0.00 0.00
Aphthitalite 0.00 0.00 0.14 0.00 0.34 0.00 0.00 0.00 0.00
Arcanite 0.00 0.00 0.32 0.18 0.00 0.12 0.12 0.00 0.00
Calcium Sulfoaluminate 0.00 0.00 0.00 0.18 0.12 0.28 0.12 0.00 0.00
Sylvite 0.00 0.64 0.22 0.06 0.04 0.78 0.08 0.00 0.00
Calcium Chloride 0.00 0.00 0.00 0.10 0.00 0.00 0.00 0.00 0.00
Amorphous 0.00 0.10 6.42 2.22 5.86 3.66 7.00 0.00 0.00
Akermanite 0.00 0.00 0.00 0.00 0.00 0.22 0.00 0.00 0.00
Calcium Dialuminium Oxide 0.00 0.00 0.00 0.00 0.08 0.28 0.20 0.00 0.00
Mullite 0.00 0.00 0.82 0.00 0.00 0.00 0.00 0.00 0.00
292
Table D.7 Mineralogical Composition of TII Blends with 10% Replacement
Components TII TII CKD A 10%
TII CKD B 10%
TII CKD C 10%
TII CKD D 10%
TII CKD E 10%
TII CKD F 10%
TII CKD LS 10%
TII CKD SLX 10%
Alite - M3 66.50 59.97 59.85 59.95 60.00 60.03 59.94 59.85 59.85
ß-Belite 15.20 15.87 14.45 14.73 14.28 15.03 14.07 13.68 13.68
Aluminate 3.00 2.75 2.75 2.77 2.75 2.84 2.75 2.70 2.70
Brownmillerite 8.90 8.03 8.07 8.07 8.01 8.25 8.06 8.01 8.01
Gypsum 1.00 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90
Hemihydrate 0.60 0.54 0.54 0.54 0.54 0.54 0.54 0.54 0.54
Calcite 0.80 5.98 4.19 5.85 2.99 0.84 1.14 10.52 0.91
Quartz 0.20 1.10 0.90 1.26 0.50 0.83 0.78 0.38 10.00
Dolomite 0.00 0.45 0.31 0.00 0.10 0.00 0.00 0.00 0.00
Periclase 2.50 2.31 2.32 2.26 2.28 2.46 2.44 2.25 2.25
Lime 0.20 0.55 0.51 0.68 1.36 3.02 3.63 0.18 0.18
Portlandite 0.40 0.36 0.38 0.36 0.36 0.47 0.68 0.36 0.36
Anhydrite 0.90 1.00 1.04 1.29 2.61 2.19 1.36 0.81 0.81
Calcium Langbeinite 0.00 0.00 0.00 0.16 0.26 0.11 0.14 0.00 0.00
Aphthitalite 0.00 0.00 0.07 0.00 0.17 0.00 0.00 0.00 0.00
Arcanite 0.00 0.00 0.16 0.09 0.00 0.06 0.06 0.00 0.00
Calcium Sulfoaluminate 0.00 0.00 0.00 0.09 0.06 0.14 0.06 0.00 0.00
Sylvite 0.00 0.32 0.11 0.03 0.02 0.39 0.04 0.00 0.00
Calcium Chloride 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00
Amorphous 0.00 0.05 3.21 1.11 2.93 1.83 3.50 0.00 0.00
Akermanite 0.00 0.00 0.00 0.00 0.00 0.11 0.00 0.00 0.00
Calcium Dialuminium Oxide 0.00 0.00 0.00 0.00 0.04 0.14 0.10 0.00 0.00
Mullite 0.00 0.00 0.41 0.00 0.00 0.00 0.00 0.00 0.00
293
Table D.8 Mineralogical Composition of TII Blends with 20% Replacement
Components TII TII CKD A 20%
TII CKD B 20%
TII CKD C 20%
TII CKD D 20%
TII CKD E 20%
TII CKD F 20%
TII CKD LS 20%
TII CKD SLX 20%
Alite - M3 66.50 53.44 53.20 53.40 53.50 53.56 53.38 53.20 53.20
ß-Belite 15.20 16.54 13.70 14.26 13.36 14.86 12.94 12.16 12.16
Aluminate 3.00 2.50 2.50 2.54 2.50 2.68 2.50 2.40 2.40
Brownmillerite 8.90 7.16 7.24 7.24 7.12 7.60 7.22 7.12 7.12
Gypsum 1.00 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80
Hemihydrate 0.60 0.48 0.48 0.48 0.48 0.48 0.48 0.48 0.48
Calcite 0.80 11.16 7.58 10.90 5.18 0.88 1.48 20.24 1.01
Quartz 0.20 2.00 1.60 2.32 0.80 1.46 1.36 0.56 19.79
Dolomite 0.00 0.90 0.62 0.00 0.20 0.00 0.00 0.00 0.00
Periclase 2.50 2.12 2.14 2.02 2.06 2.42 2.38 2.00 2.00
Lime 0.20 0.90 0.82 1.16 2.52 5.84 7.06 0.16 0.16
Portlandite 0.40 0.32 0.36 0.32 0.32 0.54 0.96 0.32 0.32
Anhydrite 0.90 1.10 1.18 1.68 4.32 3.48 1.82 0.72 0.72
Calcium Langbeinite 0.00 0.00 0.00 0.32 0.52 0.22 0.28 0.00 0.00
Aphthitalite 0.00 0.00 0.14 0.00 0.34 0.00 0.00 0.00 0.00
Arcanite 0.00 0.00 0.32 0.18 0.00 0.12 0.12 0.00 0.00
Calcium Sulfoaluminate 0.00 0.00 0.00 0.18 0.12 0.28 0.12 0.00 0.00
Sylvite 0.00 0.64 0.22 0.06 0.04 0.78 0.08 0.00 0.00
Calcium Chloride 0.00 0.00 0.00 0.10 0.00 0.00 0.00 0.00 0.00
Amorphous 0.00 0.10 6.42 2.22 5.86 3.66 7.00 0.00 0.00
Akermanite 0.00 0.00 0.00 0.00 0.00 0.22 0.00 0.00 0.00
Calcium Dialuminium Oxide 0.00 0.00 0.00 0.00 0.08 0.28 0.20 0.00 0.00
Mullite 0.00 0.00 0.82 0.00 0.00 0.00 0.00 0.00 0.00
294
Table D.9 Particle Size Distributions of CKD-PC and PC-filler Blends
Description TI TI CKD A
10% TI CKD B
10% TI CKD C
10% TI CKD D
10% TI CKD E
10% TI CKD F
10% TI CKD LS 10%
TI CKD SLX 10%
< 3.0887 8.59 9.12 9.17 9.41 9.24 8.44 9.03 9.59 9.75
<10.4804 36.69 37.19 36.80 37.37 38.30 35.58 36.82 38.58 37.78
< 22.4909 65.02 64.80 63.96 64.70 65.99 63.51 64.56 67.01 65.80
< 30.5252 78.31 77.52 76.55 77.36 78.58 76.58 77.46 79.69 78.83
< 41.4295 89.55 88.32 87.26 88.17 89.22 87.79 88.46 90.26 89.81
< 48.2654 93.65 92.34 91.25 92.21 93.16 91.99 92.55 94.10 93.81
3-30 um 69.72 68.40 67.38 67.95 69.34 68.14 68.43 70.10 69.08
30-48 um 15.34 14.82 14.71 14.85 14.58 15.41 15.09 14.40 14.98
Description TI TI CKD A
20% TI CKD B
20% TI CKD C
20% TI CKD D
20% TI CKD E
20% TI CKD F
20% TI CKD LS 20%
TI CKD SLX 20%
< 3.0887 8.59 9.66 9.75 10.24 9.90 8.29 9.47 10.58 10.91
<10.4804 36.69 37.68 36.91 38.05 39.92 34.46 36.95 40.47 38.86
< 22.4909 65.02 64.58 62.90 64.37 66.96 61.99 64.11 69.00 66.58
< 30.5252 78.31 76.73 74.78 76.41 78.85 74.86 76.60 81.07 79.35
< 41.4295 89.55 87.10 84.97 86.79 88.90 86.03 87.36 90.97 90.07
< 48.2654 93.65 91.03 88.85 90.77 92.66 90.32 91.45 94.54 93.98
3-30 um 69.72 67.07 65.03 66.17 68.95 66.56 67.14 70.49 68.44
30-48 um 15.34 14.30 14.07 14.36 13.81 15.47 14.84 13.47 14.62
DESCRIPTION TII TII CKD A 10%
TII CKD B 10%
TII CKD C 10%
TII CKD D 10%
TII CKD E 10%
TII CKD F 10%
TII CKD LS 10%
TII CKD SLX 10%
< 3.0887 10.56 10.89 10.94 11.18 11.01 10.21 10.80 11.36 11.52
<10.4804 39.09 39.35 38.96 39.53 40.46 37.74 38.98 40.74 39.94
< 22.4909 67.39 66.93 66.09 66.83 68.12 65.64 66.69 69.14 67.93
< 30.5252 79.35 78.46 77.48 78.30 79.52 77.52 78.39 80.63 79.77
< 41.4295 89.10 87.92 86.86 87.77 88.82 87.39 88.05 89.86 89.41
< 48.2654 92.73 91.51 90.42 91.38 92.32 91.16 91.72 93.26 92.98
3-30 um 68.80 67.56 66.55 67.11 68.50 67.31 67.60 69.27 68.25
30-48 um 13.38 13.05 12.94 13.08 12.81 13.63 13.32 12.63 13.21
DESCRIPTION TII TII CKD A 20%
TII CKD B 20%
TII CKD C 20%
TII CKD D 20%
TII CKD E 20%
TII CKD F 20%
TII CKD LS 20%
TII CKD SLX 20%
< 3.0887 10.56 11.23 11.32 11.81 11.47 9.87 11.04 12.16 12.49
<10.4804 39.09 39.60 38.83 39.97 41.83 36.38 38.86 42.39 40.78
< 22.4909 67.39 66.47 64.80 66.27 68.85 63.88 66.00 70.89 68.47
< 30.5252 79.35 77.56 75.61 77.24 79.68 75.69 77.44 81.90 80.19
< 41.4295 89.10 86.74 84.61 86.43 88.54 85.67 87.01 90.62 89.71
< 48.2654 92.73 90.29 88.11 90.03 91.92 89.58 90.71 93.80 93.24
3-30 um 68.80 66.33 64.29 65.43 68.21 65.82 66.40 69.75 67.70
30-48 um 13.38 12.72 12.50 12.78 12.24 13.89 13.27 11.89 13.05
295
Appendix E. Isothermal Conduction Calorimetry Results
296
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)TI
TI LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI SLX 10%
TI LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD A 10%
TI LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD B 10%
TI LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
) TI CKD C 10%
TI LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
he
at
evo
luti
on
(m
W/g
)
TI CKD D2 10%
TI LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD E 10%
TI LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD F 10%
TI LS 10%
Figure E.1 Heat of Hydration of TI cement with 10% replacement of limestone (LS), silica flour (SLX), and six CKDs (A, B, C, D, E and F).
297
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI
TI LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI SLX 20%
TI LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD A 20%
TI LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD B 20%
TI LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
he
at
ev
olu
tio
n (
mW
/g)
TI CKD C 20%
TI LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD D2 20%
TI LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD E 20%
TI LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TI CKD F 20%
TI LS 20%
`
Figure E.2 Heat of Hydration of TI cement with 20% replacement of limestone (LS), silica flour (SLX), and six CKDs (A, B, C, D, E and F).
298
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII
TII LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII SLX 10%
TII LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD A 10%
TII LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD B 10%
TII LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD C 10%
TII LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD D2 10%
TII LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD E 10%
TII LS 10%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD F 10%
TII LS 10%
Figure E.3 Heat of Hydration of TII cement with 10% replacement of limestone (LS), silica flour (SLX), and six CKDs (A, B, C, D, E and F).
299
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII
TII LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII SLX 20%
TII LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD A 20%
TII LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD B 20%
TII LS 20%
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD C 20%
TII LS 20%
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD D2 20%
TII LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD E 20%
TII LS 20%
0.0
1.0
2.0
3.0
4.0
5.0
0 4 8 12 16 20 24
time (h)
heat
evo
luti
on
(m
W/g
)
TII CKD F 20%
TII LS 20%
Figure E.4 Heat of Hydration of TII cement with 20% replacement of limestone (LS), silica flour (SLX), and six CKDs (A, B, C, D, E and F).
300
Appendix F. Mortar Flow Statistical Analysis
301
Table F.1 Mortar Flow Raw Data
TI Blends flow TII Blends flow
TI 109 TII 112
TI 107 TII 113
TI 105 TII 116
TI 107 TII 115
TI 109 TII 115
TI 108 TII 118
TI 102 TII 113
TI CKD LS 10% 110 TII CKD LS 10% 116
TI CKD LS 10% 114 TII CKD LS 10% 117
TI CKD SLX 10% 112 TII CKD SLX 10% 115
TI CKD SLX 10% 111 TII CKD SLX 10% 117
TI CKD A 10% 108 TII CKD A 10% 108
TI CKD A 10% 103 TII CKD A 10% 110
TI CKD A 10% 100 TII CKD B 10% 109
TI CKD B 10% 102 TII CKD B 10% 115
TI CKD B 10% 101 TII CKD C 10% 106
TI CKD B 10% 98 TII CKD C 10% 112
TI CKD C 10% 101 TII CKD D 10% 111
TI CKD C 10% 101 TII CKD D 10% 116
TI CKD D 10% 110 TII CKD E 10% 100
TI CKD D 10% 110 TII CKD E 10% 106
TI CKD E 10% 101 TII CKD F 10% 98
TI CKD E 10% 107 TII CKD F 10% 102
TI CKD E 10% 106 TII CKD LS 20% 116
TI CKD E 10% 96 TII CKD LS 20% 120
TI CKD E 10% 101 TII CKD SLX 20% 114
TI CKD F 10% 96 TII CKD SLX 20% 120
TI CKD F 10% 98 TII CKD A 20% 105
TI CKD F 10% 87 TII CKD A 20% 108
TI CKD F 10% 94 TII CKD B 20% 100
TI CKD LS 20% 117 TII CKD B 20% 105
TI CKD LS 20% 117 TII CKD C 20% 103
TI CKD SLX 20% 113 TII CKD C 20% 107
TI CKD SLX 20% 114 TII CKD D 20% 109
TI CKD A 20% 101 TII CKD D 20% 109
TI CKD A 20% 103 TII CKD E 20% 82
TI CKD B 20% 93 TII CKD E 20% 98
TI CKD B 20% 97 TII CKD F 20% 70
TI CKD C 20% 100 TII CKD F 20% 86
TI CKD C 20% 103 (b)
TI CKD D 20% 107
TI CKD D 20% 109
TI CKD E 20% 80
TI CKD E 20% 76
TI CKD E 20% 80
TI CKD F 20% 63
TI CKD F 20% 74
TI CKD F 20% 61
TI CKD F 20% 69
(a)
302
Oneway Analysis of Flow By Cement TI Blends
60
70
80
90
100
110
120
flow
TI
TI C
KD
A 1
0%
TI C
KD
A 2
0%
TI C
KD
B 1
0%
TI C
KD
B 2
0%
TI C
KD
C 1
0%
TI C
KD
C 2
0%
TI C
KD
D 1
0%
TI C
KD
D 2
0%
TI C
KD
E 1
0%
TI C
KD
E 2
0%
TI C
KD
F 1
0%
TI C
KD
F 2
0%
TI C
KD
LS
10%
TI C
KD
LS
20%
TI C
KD
SLX
10%
TI C
KD
SLX
20%
TI Blends
Oneway Anova Summary of Fit Rsquare 0.958229 Adj Rsquare 0.937343 Root Mean Square Error 3.363037 Mean of Response 99.63776 Observations (or Sum Wgts) 49
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TI Blends 16 8302.4621 518.904 45.8800 <.0001 Error 32 361.9205 11.310 C. Total 48 8664.3827
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TI 7 106.571 1.2711 103.98 109.16 TI CKD A 10% 3 103.583 1.9417 99.63 107.54 TI CKD A 20% 2 101.750 2.3780 96.91 106.59 TI CKD B 10% 3 100.333 1.9417 96.38 104.29 TI CKD B 20% 2 94.625 2.3780 89.78 99.47 TI CKD C 10% 2 101.000 2.3780 96.16 105.84 TI CKD C 20% 2 101.250 2.3780 96.41 106.09 TI CKD D 10% 2 109.750 2.3780 104.91 114.59 TI CKD D 20% 2 108.000 2.3780 103.16 112.84 TI CKD E 10% 5 102.050 1.5040 98.99 105.11 TI CKD E 20% 3 78.417 1.9417 74.46 82.37 TI CKD F 10% 4 93.563 1.6815 90.14 96.99 TI CKD F 20% 4 66.313 1.6815 62.89 69.74 TI CKD LS 10% 2 112.000 2.3780 107.16 116.84 TI CKD LS 20% 2 116.500 2.3780 111.66 121.34 TI CKD SLX 10% 2 111.250 2.3780 106.41 116.09 TI CKD SLX 20% 2 113.625 2.3780 108.78 118.47 Std Error uses a pooled estimate of error variance
303
Oneway Analysis of Flow By Cement TI Blends
60
70
80
90
100
110
120
flow
TI
TI C
KD
A 1
0%
TI C
KD
A 2
0%
TI C
KD
B 1
0%
TI C
KD
B 2
0%
TI C
KD
C 1
0%
TI C
KD
C 2
0%
TI C
KD
D 1
0%
TI C
KD
D 2
0%
TI C
KD
E 1
0%
TI C
KD
E 2
0%
TI C
KD
F 1
0%
TI C
KD
F 2
0%
TI C
KD
LS
10%
TI C
KD
LS
20%
TI C
KD
SLX
10%
TI C
KD
SLX
20%
TI Blends
Means and Std Deviations Level Number Mean Std Dev Std Err Mean Lower 95% Upper 95% TI 7 106.571 2.37484 0.8976 104.38 108.77 TI CKD A 10% 3 103.583 3.66003 2.1131 94.49 112.68 TI CKD A 20% 2 101.750 1.06066 0.7500 92.22 111.28 TI CKD B 10% 3 100.333 2.08167 1.2019 95.16 105.50 TI CKD B 20% 2 94.625 2.65165 1.8750 70.80 118.45 TI CKD C 10% 2 101.000 0.00000 0.0000 101.00 101.00 TI CKD C 20% 2 101.250 2.47487 1.7500 79.01 123.49 TI CKD D 10% 2 109.750 0.35355 0.2500 106.57 112.93 TI CKD D 20% 2 108.000 1.41421 1.0000 95.29 120.71 TI CKD E 10% 5 102.050 4.49444 2.0100 96.47 107.63 TI CKD E 20% 3 78.417 2.55359 1.4743 72.07 84.76 TI CKD F 10% 4 93.563 4.70981 2.3549 86.07 101.06 TI CKD F 20% 4 66.313 5.94199 2.9710 56.86 75.77 TI CKD LS 10% 2 112.000 2.82843 2.0000 86.59 137.41 TI CKD LS 20% 2 116.500 0.00000 0.0000 116.50 116.50 TI CKD SLX 10% 2 111.250 1.06066 0.7500 101.72 120.78 TI CKD SLX 20% 2 113.625 0.88388 0.6250 105.68 121.57
304
Oneway Analysis of flow By Cement TII Blends
60
70
80
90
100
110
120
130
flow
TII
TII C
KD
A 1
0%
TII C
KD
A 2
0%
TII C
KD
B 1
0%
TII C
KD
B 2
0%
TII C
KD
C 1
0%
TII C
KD
C 2
0%
TII C
KD
D 1
0%
TII C
KD
D 2
0%
TII C
KD
E 1
0%
TII C
KD
E 2
0%
TII C
KD
F 1
0%
TII C
KD
F 2
0%
TII C
KD
LS
10%
TII C
KD
LS
20%
TII C
KD
SLX
10%
TII C
KD
SLX
20%
TII Blends
Oneway Anova Summary of Fit Rsquare 0.902038 Adj Rsquare 0.830793 Root Mean Square Error 4.337334 Mean of Response 107.8205 Observations (or Sum Wgts) 39
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TII Blends 16 3810.9643 238.185 12.6610 <.0001 Error 22 413.8743 18.812 C. Total 38 4224.8386
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TII 7 114.429 1.6394 111.03 117.83 TII CKD A 10% 2 108.750 3.0670 102.39 115.11 TII CKD A 20% 2 106.375 3.0670 100.01 112.74 TII CKD B 10% 2 111.625 3.0670 105.26 117.99 TII CKD B 20% 2 102.375 3.0670 96.01 108.74 TII CKD C 10% 2 108.950 3.0670 102.59 115.31 TII CKD C 20% 2 104.750 3.0670 98.39 111.11 TII CKD D 10% 2 113.375 3.0670 107.01 119.74 TII CKD D 20% 2 109.000 3.0670 102.64 115.36 TII CKD E 10% 2 103.000 3.0670 96.64 109.36 TII CKD E 20% 2 89.625 3.0670 83.26 95.99 TII CKD F 10% 2 99.625 3.0670 93.26 105.99 TII CKD F 20% 2 77.500 3.0670 71.14 83.86 TII CKD LS 10% 2 116.375 3.0670 110.01 122.74 TII CKD LS 20% 2 117.875 3.0670 111.51 124.24 TII CKD SLX 10% 2 116.000 3.0670 109.64 122.36 TII CKD SLX 20% 2 116.800 3.0670 110.44 123.16 Std Error uses a pooled estimate of error variance
305
Oneway Analysis of flow By Cement TII Blends
60
70
80
90
100
110
120
130
flow
TII
TII C
KD
A 1
0%
TII C
KD
A 2
0%
TII C
KD
B 1
0%
TII C
KD
B 2
0%
TII C
KD
C 1
0%
TII C
KD
C 2
0%
TII C
KD
D 1
0%
TII C
KD
D 2
0%
TII C
KD
E 1
0%
TII C
KD
E 2
0%
TII C
KD
F 1
0%
TII C
KD
F 2
0%
TII C
KD
LS
10%
TII C
KD
LS
20%
TII C
KD
SLX
10%
TII C
KD
SLX
20%
TII Blends
Means and Std Deviations Level Number Mean Std Dev Std Err Mean Lower 95% Upper 95% TII 7 114.429 1.9133 0.7232 112.7 116.20 TII CKD A 10% 2 108.750 1.4142 1.0000 96.0 121.46 TII CKD A 20% 2 106.375 2.6517 1.8750 82.6 130.20 TII CKD B 10% 2 111.625 4.4194 3.1250 71.9 151.33 TII CKD B 20% 2 102.375 3.7123 2.6250 69.0 135.73 TII CKD C 10% 2 108.950 3.9598 2.8000 73.4 144.53 TII CKD C 20% 2 104.750 2.8284 2.0000 79.3 130.16 TII CKD D 10% 2 113.375 4.0659 2.8750 76.8 149.91 TII CKD D 20% 2 109.000 0.0000 0.0000 109.0 109.00 TII CKD E 10% 2 103.000 3.8891 2.7500 68.1 137.94 TII CKD E 20% 2 89.625 11.1369 7.8750 -10.4 189.69 TII CKD F 10% 2 99.625 2.6517 1.8750 75.8 123.45 TII CKD F 20% 2 77.500 11.3137 8.0000 -24.1 179.15 TII CKD LS 10% 2 116.375 0.5303 0.3750 111.6 121.14 TII CKD LS 20% 2 117.875 3.3588 2.3750 87.7 148.05 TII CKD SLX 10% 2 116.000 1.7678 1.2500 100.1 131.88 TII CKD SLX 20% 2 116.800 4.5255 3.2000 76.1 157.46
306
Appendix G. Mortar Compressive Strength Statistical Analysis
307
Table G.1 Individual Compressive Strength (MPa)
TI Blends 1d 3d 7d 28d 90d TII Blends 1d 3d 7d 28d 90d
TI 15.9 26.4 27.6 36.6 40.2 TII 13.8 23.1 27.8 36.5 42.8
TI 16.0 25.2 29.3 35.5 42.1 TII 13.3 23.7 28.2 36.7 42.2
TI 15.9 24.3 29.4 36.5 39.8 TII 14.3 21.6 27.1 37.7 42.0
TI CKD LS 10% 15.1 26.8 31.5 36.0 45.3 TII CKD LS 10% 13.1 21.5 29.1 36.8 42.2
TI CKD LS 10% 15.1 26.2 30.1 38.8 44.1 TII CKD LS 10% 12.5 21.7 28.8 35.1 41.1
TI CKD LS 10% 14.4 26.2 29.3 36.9 42.6 TII CKD LS 10% 12.8 21.5 28.3 35.3 40.5
TI CKD SLX 10% 15.5 24.5 27.8 34.4 39.2 TII CKD SLX 10% 11.7 19.2 22.7 30.7 35.2
TI CKD SLX 10% 15.2 24.7 29.0 35.9 38.6 TII CKD SLX 10% 12.0 19.8 24.6 31.5 37.2
TI CKD SLX 10% 15.1 24.2 27.6 34.8 38.5 TII CKD SLX 10% 12.9 20.3 24.3 31.9 36.0
TI CKD A 10% 17.9 27.4 32.2 37.5 44.4 TII CKD A 10% 15.6 23.6 28.9 34.6 39.9
TI CKD A 10% 17.9 28.6 32.5 37.3 43.7 TII CKD A 10% 14.8 23.8 29.3 37.1 42.6
TI CKD A 10% 17.8 27.9 32.6 38.4 44.9 TII CKD A 10% 14.8 23.3 27.8 36.5 43.4
TI CKD B 10% 16.0 26.8 30.5 35.8 42.0 TII CKD B 10% 14.3 22.2 28.3 35.6 43.2
TI CKD B 10% 16.4 25.7 30.1 38.0 42.6 TII CKD B 10% 14.1 23.5 29.3 34.8 42.2
TI CKD B 10% 16.1 26.6 29.3 37.2 39.7 TII CKD B 10% 15.6 24.2 26.3 35.6 40.8
TI CKD C 10% 15.3 26.6 29.6 36.1 40.6 TII CKD C 10% 14.4 23.0 27.8 34.2 42.2
TI CKD C 10% 14.8 26.3 28.9 35.8 38.8 TII CKD C 10% 14.6 23.4 25.8 34.0 41.8
TI CKD C 10% 15.1 26.5 30.7 38.2 38.9 TII CKD C 10% 15.1 23.7 27.9 35.1 40.4
TI CKD D 10% 11.9 24.5 32.5 41.7 43.3 TII CKD D 10% 12.7 21.2 25.9 34.7 40.6
TI CKD D 10% 11.5 24.5 31.4 39.9 47.1 TII CKD D 10% 12.7 21.6 26.4 34.2 43.4
TI CKD D 10% 11.6 24.0 32.6 41.9 47.6 TII CKD D 10% 13.0 21.3 26.0 35.4 42.7
TI CKD E 10% 15.2 26.2 33.0 36.2 44.3 TII CKD E 10% 14.7 24.0 28.9 36.4 43.0
TI CKD E 10% 14.2 26.8 32.4 36.9 43.6 TII CKD E 10% 15.2 23.5 30.1 36.1 42.3
TI CKD E 10% 14.9 27.0 31.8 36.4 43.5 TII CKD E 10% 15.1 24.3 30.2 38.4 44.2
TI CKD F 10% 14.4 27.2 33.1 37.9 41.1 TII CKD F 10% 13.3 22.0 27.7 40.0 43.6
TI CKD F 10% 14.5 27.6 31.4 40.2 41.5 TII CKD F 10% 13.8 22.7 29.6 38.3 41.2
TI CKD F 10% 14.0 27.3 31.0 39.8 41.6 TII CKD F 10% 14.1 23.9 30.1 36.9 42.3
TI CKD LS 20% 12.4 23.2 26.4 33.9 37.2 TII CKD LS 20% 11.1 19.4 25.5 31.1 35.6
TI CKD LS 20% 12.5 22.9 27.8 32.6 37.1 TII CKD LS 20% 11.0 18.1 24.1 30.2 34.0
TI CKD LS 20% 12.6 23.3 27.0 32.8 38.5 TII CKD LS 20% 10.9 17.8 24.5 29.9 35.0
TI CKD SLX 20% 13.4 21.7 24.9 32.3 33.5 TII CKD SLX 20% 11.2 18.5 19.8 28.1 31.1
TI CKD SLX 20% 12.9 21.7 26.3 31.4 35.2 TII CKD SLX 20% 10.9 18.8 20.4 27.6 31.2
TI CKD SLX 20% 13.5 21.4 25.0 31.0 35.8 TII CKD SLX 20% 11.1 17.7 21.2 28.5 32.6
TI CKD A 20% 15.5 25.1 28.7 34.4 40.1 TII CKD A 20% 13.7 22.5 26.1 32.8 39.3
TI CKD A 20% 16.2 24.6 29.2 33.9 40.7 TII CKD A 20% 12.9 21.5 26.4 32.5 37.4
TI CKD A 20% 15.6 26.1 29.2 34.7 40.9 TII CKD A 20% 13.3 21.5 25.6 32.0 37.0
TI CKD B 20% 14.2 24.0 27.3 33.3 39.7 TII CKD B 20% 13.9 21.8 27.2 31.1 38.0
TI CKD B 20% 14.2 24.0 28.0 33.6 38.9 TII CKD B 20% 13.9 21.2 26.5 30.8 40.2
TI CKD B 20% 14.6 23.3 27.8 34.6 40.0 TII CKD B 20% 14.4 22.1 26.8 31.0 36.6
TI CKD C 20% 13.0 24.8 28.4 33.9 37.5 TII CKD C 20% 12.6 20.4 24.2 30.5 37.4
TI CKD C 20% 13.7 24.8 29.0 33.0 37.9 TII CKD C 20% 11.6 21.4 26.2 31.5 39.3
TI CKD C 20% 13.2 24.2 28.1 29.9 37.3 TII CKD C 20% 12.3 21.2 25.5 30.8 37.1
TI CKD D 20% 10.7 18.2 22.4 37.8 46.8 TII CKD D 20% 11.1 15.9 20.5 31.7 42.1
TI CKD D 20% 10.2 17.9 23.9 37.7 45.2 TII CKD D 20% 10.6 16.6 19.4 35.1 43.1
TI CKD D 20% 10.4 17.6 21.6 34.0 44.2 TII CKD D 20% 10.5 15.8 21.5 32.8 40.5
TI CKD E 20% 10.9 21.4 28.3 36.8 42.6 TII CKD E 20% 11.1 18.1 24.1 35.3 41.3
TI CKD E 20% 10.6 21.4 27.8 35.4 42.9 TII CKD E 20% 10.6 18.4 25.9 33.1 38.3
TI CKD E 20% 11.0 23.6 29.6 35.9 42.5 TII CKD E 20% 11.6 17.4 25.0 32.8 39.4
TI CKD F 20% 11.8 24.5 30.7 35.4 42.5 TII CKD F 20% 11.8 19.8 28.5 36.1 40.8
TI CKD F 20% 11.4 22.8 32.1 36.7 42.5 TII CKD F 20% 11.7 20.7 28.2 37.0 40.8
TI CKD F 20% 11.3 23.7 33.1 35.9 42.2 TII CKD F 20% 12.0 20.8 28.5 35.6 39.2
(a) (b)
308
Table G.2 Average Compressive Strengths
MPa Percentage of TI
1d 3d 7d 28d 90d 1d 3d 7d 28d 90d
TI 15.9 25.3 28.7 36.0 40.0 100% 100% 100% 100% 100%
TI LS 10% 14.9 25.9 30.3 37.2 44.0 93% 103% 105% 103% 110%
TI SLX 10% 15.2 24.0 28.1 35.0 38.8 96% 95% 98% 97% 97%
TI CKD A 10% 17.9 27.9 32.4 37.7 44.3 112% 110% 113% 105% 111%
TI CKD B 10% 16.2 26.4 30.0 37.0 41.5 102% 104% 104% 103% 104%
TI CKD C 10% 15.1 26.5 29.7 36.7 39.4 95% 105% 104% 102% 99%
TI CKD D 10% 11.7 24.3 32.1 41.2 46.0 73% 96% 112% 114% 115%
TI CKD E 10% 14.8 26.7 32.4 36.5 45.4 93% 105% 113% 101% 114%
TI CKD F 10% 14.3 27.4 31.8 39.3 41.4 90% 108% 111% 109% 104%
TI LS 20% 12.5 22.6 27.1 33.1 37.6 78% 89% 94% 92% 94%
TI SLX 20% 13.2 21.1 25.4 31.6 34.8 83% 83% 88% 88% 87%
TI CKD A 20% 15.7 25.3 29.0 34.3 40.6 99% 100% 101% 95% 102%
TI CKD B 20% 14.3 23.8 27.7 33.8 39.5 90% 94% 96% 94% 99%
TI CKD C 20% 13.3 24.6 28.5 32.3 37.6 84% 97% 99% 90% 94%
TI CKD D 20% 10.4 17.9 22.2 35.7 45.4 65% 71% 77% 99% 114%
TI CKD E 20% 10.8 22.1 27.3 36.0 42.7 68% 87% 95% 100% 107%
TI CKD F 20% 11.5 23.7 30.7 36.0 42.3 72% 94% 107% 100% 106%
MPa Percentage of TII
1d 3d 7d 28d 90d 1d 3d 7d 28d 90d
TII 13.8 22.6 27.6 37.0 42.5 100% 100% 100% 100% 100%
TII LS 10% 12.8 21.5 28.7 35.7 41.2 93% 95% 104% 97% 97%
TII SLX 10% 12.2 19.8 23.4 30.7 35.4 88% 87% 85% 83% 83%
TII CKD A 10% 15.0 23.6 28.7 36.1 42.0 109% 104% 104% 98% 99%
TII CKD B 10% 14.6 23.3 28.0 35.3 42.1 106% 103% 101% 96% 99%
TII CKD C 10% 14.7 23.3 27.2 34.4 41.5 107% 103% 98% 93% 98%
TII CKD D 10% 12.8 21.3 26.1 34.8 41.4 93% 94% 94% 94% 97%
TII CKD E 10% 15.0 23.9 29.7 36.9 42.3 109% 106% 108% 100% 100%
TII CKD F 10% 13.7 22.9 29.2 38.4 42.4 99% 101% 105% 104% 100%
TII LS 20% 11.0 18.4 24.7 30.4 34.9 80% 81% 89% 82% 82%
TII SLX 20% 11.1 18.3 20.0 27.5 31.0 80% 81% 72% 74% 73%
TII CKD A 20% 13.3 21.8 26.0 32.4 37.9 96% 96% 94% 88% 89%
TII CKD B 20% 14.1 21.7 26.8 31.0 38.3 102% 96% 97% 84% 90%
TII CKD C 20% 12.2 21.0 25.3 30.9 37.9 88% 93% 92% 84% 89%
TII CKD D 20% 10.7 16.1 20.5 33.2 41.0 78% 71% 74% 90% 96%
TII CKD E 20% 10.9 18.0 25.4 33.7 38.8 79% 79% 92% 91% 91%
TII CKD F 20% 11.8 20.5 28.4 37.7 40.3 86% 90% 103% 102% 95%
309
Oneway Analysis of 1d By Cement TI Blends
10
11
12
13
14
15
16
17
18
1d
TI
TI C
KD
A 1
0%
TI C
KD
A 2
0%
TI C
KD
B 1
0%
TI C
KD
B 2
0%
TI C
KD
C 1
0%
TI C
KD
C 2
0%
TI C
KD
D 1
0%
TI C
KD
D 2
0%
TI C
KD
E 1
0%
TI C
KD
E 2
0%
TI C
KD
F 1
0%
TI C
KD
F 2
0%
TI C
KD
LS
10%
TI C
KD
LS
20%
TI C
KD
SLX
10%
TI C
KD
SLX
20%
TI Blends
Oneway Anova Summary of Fit Rsquare 0.986739 Adj Rsquare 0.980499 Root Mean Square Error 0.285478 Mean of Response 13.99275 Observations (or Sum Wgts) 51
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TI Blends 16 206.18427 12.8865 158.1217 <.0001 Error 34 2.77091 0.0815 C. Total 50 208.95518
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TI 3 15.9338 0.16482 15.599 16.269 TI CKD A 10% 3 17.8681 0.16482 17.533 18.203 TI CKD A 20% 3 15.7455 0.16482 15.411 16.080 TI CKD B 10% 3 16.1906 0.16482 15.856 16.526 TI CKD B 20% 3 14.3424 0.16482 14.007 14.677 TI CKD C 10% 3 15.0781 0.16482 14.743 15.413 TI CKD C 20% 3 13.3155 0.16482 12.981 13.650 TI CKD D 10% 3 11.6558 0.16482 11.321 11.991 TI CKD D 20% 3 10.4066 0.16482 10.072 10.742 TI CKD E 10% 3 14.7875 0.16482 14.453 15.122 TI CKD E 20% 3 10.8339 0.16482 10.499 11.169 TI CKD F 10% 3 14.3085 0.16482 13.974 14.643 TI CKD F 20% 3 11.5306 0.16482 11.196 11.866 TI CKD LS 10% 3 14.8897 0.16482 14.555 15.225 TI CKD LS 20% 3 12.4937 0.16482 12.159 12.829 TI CKD SLX 10% 3 15.2493 0.16482 14.914 15.584 TI CKD SLX 20% 3 13.2472 0.16482 12.912 13.582 Std Error uses a pooled estimate of error variance
310
Oneway Analysis of 1d By Cement TII Blends
10
11
12
13
14
15
16
1d
TII
TII C
KD
A 1
0%
TII C
KD
A 2
0%
TII C
KD
B 1
0%
TII C
KD
B 2
0%
TII C
KD
C 1
0%
TII C
KD
C 2
0%
TII C
KD
D 1
0%
TII C
KD
D 2
0%
TII C
KD
E 1
0%
TII C
KD
E 2
0%
TII C
KD
F 1
0%
TII C
KD
F 2
0%
TII C
KD
LS
10%
TII C
KD
LS
20%
TII C
KD
SLX
10%
TII C
KD
SLX
20%
TII Blends
Oneway Anova Summary of Fit Rsquare 0.949956 Adj Rsquare 0.926405 Root Mean Square Error 0.40549 Mean of Response 12.94315 Observations (or Sum Wgts) 51
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TII Blends 16 106.11768 6.63235 40.3373 <.0001 Error 34 5.59036 0.16442 C. Total 50 111.70804
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TII 3 13.8112 0.23411 13.335 14.287 TII CKD A 10% 3 15.0448 0.23411 14.569 15.521 TII CKD A 20% 3 13.2991 0.23411 12.823 13.775 TII CKD B 10% 3 14.6336 0.23411 14.158 15.109 TII CKD B 20% 3 14.0512 0.23411 13.575 14.527 TII CKD C 10% 3 14.7186 0.23411 14.243 15.194 TII CKD C 20% 3 12.1514 0.23411 11.676 12.627 TII CKD D 10% 3 12.8365 0.23411 12.361 13.312 TII CKD D 20% 3 10.7483 0.23411 10.273 11.224 TII CKD E 10% 3 15.0121 0.23411 14.536 15.488 TII CKD E 20% 3 11.0906 0.23411 10.615 11.566 TII CKD F 10% 3 13.7256 0.23411 13.250 14.201 TII CKD F 20% 3 11.8091 0.23411 11.333 12.285 TII CKD LS 10% 3 12.8187 0.23411 12.343 13.295 TII CKD LS 20% 3 11.0223 0.23411 10.547 11.498 TII CKD SLX 10% 3 12.1864 0.23411 11.711 12.662 TII CKD SLX 20% 3 11.0740 0.23411 10.598 11.550 Std Error uses a pooled estimate of error variance
311
Oneway Analysis of 3d By Cement TI Blends
16
18
20
22
24
26
28
30
3d
TI
TI C
KD
A 1
0%
TI C
KD
A 2
0%
TI C
KD
B 1
0%
TI C
KD
B 2
0%
TI C
KD
C 1
0%
TI C
KD
C 2
0%
TI C
KD
D 1
0%
TI C
KD
D 2
0%
TI C
KD
E 1
0%
TI C
KD
E 2
0%
TI C
KD
F 1
0%
TI C
KD
F 2
0%
TI C
KD
LS
10%
TI C
KD
LS
20%
TI C
KD
SLX
10%
TI C
KD
SLX
20%
TI Blends
Oneway Anova Summary of Fit Rsquare 0.962887 Adj Rsquare 0.945423 Root Mean Square Error 0.577871 Mean of Response 24.55801 Observations (or Sum Wgts) 51
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TI Blends 16 294.57345 18.4108 55.1331 <.0001 Error 34 11.35377 0.3339 C. Total 50 305.92722
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TI 3 25.2785 0.33363 24.601 25.957 TI CKD A 10% 3 27.9824 0.33363 27.304 28.660 TI CKD A 20% 3 25.2596 0.33363 24.582 25.938 TI CKD B 10% 3 26.3738 0.33363 25.696 27.052 TI CKD B 20% 3 23.7899 0.33363 23.112 24.468 TI CKD C 10% 3 26.5110 0.33363 25.833 27.189 TI CKD C 20% 3 24.5945 0.33363 23.917 25.273 TI CKD D 10% 3 24.3378 0.33363 23.660 25.016 TI CKD D 20% 3 17.9020 0.33363 17.224 18.580 TI CKD E 10% 3 26.6649 0.33363 25.987 27.343 TI CKD E 20% 3 22.1123 0.33363 21.434 22.790 TI CKD F 10% 3 27.3708 0.33363 26.693 28.049 TI CKD F 20% 3 23.6871 0.33363 23.009 24.365 TI CKD LS 10% 3 26.4255 0.33363 25.747 27.103 TI CKD LS 20% 3 23.1220 0.33363 22.444 23.800 TI CKD SLX 10% 3 24.4745 0.33363 23.796 25.153 TI CKD SLX 20% 3 21.5995 0.33363 20.921 22.277 Std Error uses a pooled estimate of error variance
312
Oneway Analysis of 3d By Cement TII Blends
15
16
17
18
19
20
21
22
23
24
25
3d
TII
TII C
KD
A 1
0%
TII C
KD
A 2
0%
TII C
KD
B 1
0%
TII C
KD
B 2
0%
TII C
KD
C 1
0%
TII C
KD
C 2
0%
TII C
KD
D 1
0%
TII C
KD
D 2
0%
TII C
KD
E 1
0%
TII C
KD
E 2
0%
TII C
KD
F 1
0%
TII C
KD
F 2
0%
TII C
KD
LS
10%
TII C
KD
LS
20%
TII C
KD
SLX
10%
TII C
KD
SLX
20%
TII Blends
Oneway Anova Summary of Fit Rsquare 0.949156 Adj Rsquare 0.92523 Root Mean Square Error 0.627122 Mean of Response 21.07458 Observations (or Sum Wgts) 51
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TII Blends 16 249.62152 15.6013 39.6696 <.0001 Error 34 13.37159 0.3933 C. Total 50 262.99311
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TII 3 22.7969 0.36207 22.061 23.533 TII CKD A 10% 3 23.5504 0.36207 22.815 24.286 TII CKD A 20% 3 21.8217 0.36207 21.086 22.558 TII CKD B 10% 3 23.3109 0.36207 22.575 24.047 TII CKD B 20% 3 21.7017 0.36207 20.966 22.438 TII CKD C 10% 3 23.3448 0.36207 22.609 24.081 TII CKD C 20% 3 21.0005 0.36207 20.265 21.736 TII CKD D 10% 3 21.3422 0.36207 20.606 22.078 TII CKD D 20% 3 16.0878 0.36207 15.352 16.824 TII CKD E 10% 3 23.9438 0.36207 23.208 24.680 TII CKD E 20% 3 17.9704 0.36207 17.235 18.706 TII CKD F 10% 3 22.8825 0.36207 22.147 23.618 TII CKD F 20% 3 20.4526 0.36207 19.717 21.188 TII CKD LS 10% 3 21.5484 0.36207 20.813 22.284 TII CKD LS 20% 3 18.4160 0.36207 17.680 19.152 TII CKD SLX 10% 3 19.7674 0.36207 19.032 20.503 TII CKD SLX 20% 3 18.3299 0.36207 17.594 19.066 Std Error uses a pooled estimate of error variance
313
Oneway Analysis of 7d By Cement TI Blends
20
22
24
26
28
30
32
34
7d
TI
TI C
KD
A 1
0%
TI C
KD
A 2
0%
TI C
KD
B 1
0%
TI C
KD
B 2
0%
TI C
KD
C 1
0%
TI C
KD
C 2
0%
TI C
KD
D 1
0%
TI C
KD
D 2
0%
TI C
KD
E 1
0%
TI C
KD
E 2
0%
TI C
KD
F 1
0%
TI C
KD
F 2
0%
TI C
KD
LS
10%
TI C
KD
LS
20%
TI C
KD
SLX
10%
TI C
KD
SLX
20%
TI Blends
Oneway Anova Summary of Fit Rsquare 0.936064 Adj Rsquare 0.905977 Root Mean Square Error 0.823119 Mean of Response 29.20319 Observations (or Sum Wgts) 51
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TI Blends 16 337.26034 21.0788 31.1114 <.0001 Error 34 23.03587 0.6775 C. Total 50 360.29621
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TI 3 28.7704 0.47523 27.805 29.736 TI CKD A 10% 3 32.3989 0.47523 31.433 33.365 TI CKD A 20% 3 29.0099 0.47523 28.044 29.976 TI CKD B 10% 3 29.9851 0.47523 29.019 30.951 TI CKD B 20% 3 27.6918 0.47523 26.726 28.658 TI CKD C 10% 3 29.7117 0.47523 28.746 30.677 TI CKD C 20% 3 28.4964 0.47523 27.531 29.462 TI CKD D 10% 3 32.1422 0.47523 31.176 33.108 TI CKD D 20% 3 22.6258 0.47523 21.660 23.592 TI CKD E 10% 3 32.4000 0.47523 31.434 33.366 TI CKD E 20% 3 28.5820 0.47523 27.616 29.548 TI CKD F 10% 3 31.7999 0.47523 30.834 32.766 TI CKD F 20% 3 31.9705 0.47523 31.005 32.936 TI CKD LS 10% 3 30.2762 0.47523 29.310 31.242 TI CKD LS 20% 3 27.0756 0.47523 26.110 28.041 TI CKD SLX 10% 3 28.1364 0.47523 27.171 29.102 TI CKD SLX 20% 3 25.3813 0.47523 24.416 26.347 Std Error uses a pooled estimate of error variance
314
Oneway Analysis of 7d By Cement TII Blends
18
20
22
24
26
28
30
32
7d
TII
TII C
KD
A 1
0%
TII C
KD
A 2
0%
TII C
KD
B 1
0%
TII C
KD
B 2
0%
TII C
KD
C 1
0%
TII C
KD
C 2
0%
TII C
KD
D 1
0%
TII C
KD
D 2
0%
TII C
KD
E 1
0%
TII C
KD
E 2
0%
TII C
KD
F 1
0%
TII C
KD
F 2
0%
TII C
KD
LS
10%
TII C
KD
LS
20%
TII C
KD
SLX
10%
TII C
KD
SLX
20%
TII Blends
Oneway Anova Summary of Fit Rsquare 0.935972 Adj Rsquare 0.905841 Root Mean Square Error 0.856028 Mean of Response 26.25454 Observations (or Sum Wgts) 51
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TII Blends 16 364.20427 22.7628 31.0634 <.0001 Error 34 24.91466 0.7328 C. Total 50 389.11893
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TII 3 27.7091 0.49423 26.705 28.713 TII CKD A 10% 3 28.6676 0.49423 27.663 29.672 TII CKD A 20% 3 26.0320 0.49423 25.028 27.036 TII CKD B 10% 3 27.9807 0.49423 26.976 28.985 TII CKD B 20% 3 26.8016 0.49423 25.797 27.806 TII CKD C 10% 3 27.1790 0.49423 26.175 28.183 TII CKD C 20% 3 25.3302 0.49423 24.326 26.335 TII CKD D 10% 3 26.0923 0.49423 25.088 27.097 TII CKD D 20% 3 20.4697 0.49423 19.465 21.474 TII CKD E 10% 3 29.7289 0.49423 28.725 30.733 TII CKD E 20% 3 24.9839 0.49423 23.980 25.988 TII CKD F 10% 3 29.1638 0.49423 28.159 30.168 TII CKD F 20% 3 28.4448 0.49423 27.440 29.449 TII CKD LS 10% 3 28.7359 0.49423 27.732 29.740 TII CKD LS 20% 3 24.6962 0.49423 23.692 25.701 TII CKD SLX 10% 3 23.8588 0.49423 22.854 24.863 TII CKD SLX 20% 3 20.4526 0.49423 19.448 21.457 Std Error uses a pooled estimate of error variance
315
Oneway Analysis of 28d By Cement TI Blends
28
30
32
34
36
38
40
42
28d
TI
TI C
KD
A 1
0%
TI C
KD
A 2
0%
TI C
KD
B 1
0%
TI C
KD
B 2
0%
TI C
KD
C 1
0%
TI C
KD
C 2
0%
TI C
KD
D 1
0%
TI C
KD
D 2
0%
TI C
KD
E 1
0%
TI C
KD
E 2
0%
TI C
KD
F 1
0%
TI C
KD
F 2
0%
TI C
KD
LS
10%
TI C
KD
LS
20%
TI C
KD
SLX
10%
TI C
KD
SLX
20%
TI Blends
Oneway Anova Summary of Fit Rsquare 0.872309 Adj Rsquare 0.812218 Root Mean Square Error 1.107147 Mean of Response 35.90854 Observations (or Sum Wgts) 51
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TI Blends 16 284.70643 17.7942 14.5167 <.0001 Error 34 41.67630 1.2258 C. Total 50 326.38273
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TI 3 36.1636 0.63921 34.865 37.463 TI CKD A 10% 3 37.7039 0.63921 36.405 39.003 TI CKD A 20% 3 34.3148 0.63921 33.016 35.614 TI CKD B 10% 3 37.0026 0.63921 35.704 38.302 TI CKD B 20% 3 33.8198 0.63921 32.521 35.119 TI CKD C 10% 3 36.7120 0.63921 35.413 38.011 TI CKD C 20% 3 32.2796 0.63921 30.981 33.579 TI CKD D 10% 3 41.1957 0.63921 39.897 42.495 TI CKD D 20% 3 36.4965 0.63921 35.197 37.796 TI CKD E 10% 3 36.5164 0.63921 35.217 37.815 TI CKD E 20% 3 36.0209 0.63921 34.722 37.320 TI CKD F 10% 3 39.3131 0.63921 38.014 40.612 TI CKD F 20% 3 35.9924 0.63921 34.693 37.291 TI CKD LS 10% 3 37.2421 0.63921 35.943 38.541 TI CKD LS 20% 3 33.1007 0.63921 31.802 34.400 TI CKD SLX 10% 3 35.0168 0.63921 33.718 36.316 TI CKD SLX 20% 3 31.5541 0.63921 30.255 32.853 Std Error uses a pooled estimate of error variance
316
Oneway Analysis of 28d By Cement TII Blends
26
28
30
32
34
36
38
40
42
28d
TII
TII C
KD
A 1
0%
TII C
KD
A 2
0%
TII C
KD
B 1
0%
TII C
KD
B 2
0%
TII C
KD
C 1
0%
TII C
KD
C 2
0%
TII C
KD
D 1
0%
TII C
KD
D 2
0%
TII C
KD
E 1
0%
TII C
KD
E 2
0%
TII C
KD
F 1
0%
TII C
KD
F 2
0%
TII C
KD
LS
10%
TII C
KD
LS
20%
TII C
KD
SLX
10%
TII C
KD
SLX
20%
TII Blends
Oneway Anova Summary of Fit Rsquare 0.929448 Adj Rsquare 0.896247 Root Mean Square Error 0.926892 Mean of Response 33.87856 Observations (or Sum Wgts) 51
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TII Blends 16 384.81536 24.0510 27.9946 <.0001 Error 34 29.21035 0.8591 C. Total 50 414.02571
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TII 3 36.9510 0.53514 35.863 38.038 TII CKD A 10% 3 36.0786 0.53514 34.991 37.166 TII CKD A 20% 3 32.4334 0.53514 31.346 33.521 TII CKD B 10% 3 35.3429 0.53514 34.255 36.430 TII CKD B 20% 3 30.9643 0.53514 29.877 32.052 TII CKD C 10% 3 34.4182 0.53514 33.331 35.506 TII CKD C 20% 3 30.9103 0.53514 29.823 31.998 TII CKD D 10% 3 34.7772 0.53514 33.690 35.865 TII CKD D 20% 3 33.1863 0.53514 32.099 34.274 TII CKD E 10% 3 36.9343 0.53514 35.847 38.022 TII CKD E 20% 3 33.7336 0.53514 32.646 34.821 TII CKD F 10% 3 38.3890 0.53514 37.302 39.477 TII CKD F 20% 3 36.2433 0.53514 35.156 37.331 TII CKD LS 10% 3 35.7363 0.53514 34.649 36.824 TII CKD LS 20% 3 30.4135 0.53514 29.326 31.501 TII CKD SLX 10% 3 31.3548 0.53514 30.267 32.442 TII CKD SLX 20% 3 28.0686 0.53514 26.981 29.156 Std Error uses a pooled estimate of error variance
317
Oneway Analysis of 90d By Cement TI Blends
35
40
45
50
90d
TI
TI C
KD
A 1
0%
TI C
KD
A 2
0%
TI C
KD
B 1
0%
TI C
KD
B 2
0%
TI C
KD
C 1
0%
TI C
KD
C 2
0%
TI C
KD
D 1
0%
TI C
KD
D 2
0%
TI C
KD
E 1
0%
TI C
KD
E 2
0%
TI C
KD
F 1
0%
TI C
KD
F 2
0%
TI C
KD
LS
10%
TI C
KD
LS
20%
TI C
KD
SLX
10%
TI C
KD
SLX
20%
TI Blends
Oneway Anova Summary of Fit Rsquare 0.927228 Adj Rsquare 0.892982 Root Mean Square Error 1.012278 Mean of Response 41.20939 Observations (or Sum Wgts) 51
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TI Blends 16 443.91665 27.7448 27.0758 <.0001 Error 34 34.84005 1.0247 C. Total 50 478.75670
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TI 3 40.7386 0.58444 39.551 41.926 TI CKD A 10% 3 44.3447 0.58444 43.157 45.532 TI CKD A 20% 3 40.5623 0.58444 39.375 41.750 TI CKD B 10% 3 41.4524 0.58444 40.265 42.640 TI CKD B 20% 3 39.5360 0.58444 38.348 40.724 TI CKD C 10% 3 39.4153 0.58444 38.228 40.603 TI CKD C 20% 3 37.5844 0.58444 36.397 38.772 TI CKD D 10% 3 46.0068 0.58444 44.819 47.195 TI CKD D 20% 3 45.4000 0.58444 44.212 46.588 TI CKD E 10% 3 43.8101 0.58444 42.622 44.998 TI CKD E 20% 3 42.6517 0.58444 41.464 43.839 TI CKD F 10% 3 41.4140 0.58444 40.226 42.602 TI CKD F 20% 3 42.3845 0.58444 41.197 43.572 TI CKD LS 10% 3 44.0357 0.58444 42.848 45.223 TI CKD LS 20% 3 37.6005 0.58444 36.413 38.788 TI CKD SLX 10% 3 38.7789 0.58444 37.591 39.967 TI CKD SLX 20% 3 34.8438 0.58444 33.656 36.032 Std Error uses a pooled estimate of error variance
318
Oneway Analysis of 90d By Cement TII Blends
30
32.5
35
37.5
40
42.5
45
90d
TII
TII C
KD
A 1
0%
TII C
KD
A 2
0%
TII C
KD
B 1
0%
TII C
KD
B 2
0%
TII C
KD
C 1
0%
TII C
KD
C 2
0%
TII C
KD
D 1
0%
TII C
KD
D 2
0%
TII C
KD
E 1
0%
TII C
KD
E 2
0%
TII C
KD
F 1
0%
TII C
KD
F 2
0%
TII C
KD
LS
10%
TII C
KD
LS
20%
TII C
KD
SLX
10%
TII C
KD
SLX
20%
TII Blends
Oneway Anova Summary of Fit Rsquare 0.909702 Adj Rsquare 0.867209 Root Mean Square Error 1.195474 Mean of Response 39.72669 Observations (or Sum Wgts) 51
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TII Blends 16 489.53341 30.5958 21.4083 <.0001 Error 34 48.59138 1.4292 C. Total 50 538.12478
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TII 3 42.3254 0.69021 40.923 43.728 TII CKD A 10% 3 41.9659 0.69021 40.563 43.369 TII CKD A 20% 3 37.8923 0.69021 36.490 39.295 TII CKD B 10% 3 42.0681 0.69021 40.665 43.471 TII CKD B 20% 3 38.2518 0.69021 36.849 39.654 TII CKD C 10% 3 41.4524 0.69021 40.050 42.855 TII CKD C 20% 3 37.9267 0.69021 36.524 39.329 TII CKD D 10% 3 42.2565 0.69021 40.854 43.659 TII CKD D 20% 3 41.8803 0.69021 40.478 43.283 TII CKD E 10% 3 43.1467 0.69021 41.744 44.549 TII CKD E 20% 3 39.6382 0.69021 38.236 41.041 TII CKD F 10% 3 42.3891 0.69021 40.986 43.792 TII CKD F 20% 3 40.2544 0.69021 38.852 41.657 TII CKD LS 10% 3 41.2468 0.69021 39.844 42.650 TII CKD LS 20% 3 34.8633 0.69021 33.461 36.266 TII CKD SLX 10% 3 36.1504 0.69021 34.748 37.553 TII CKD SLX 20% 3 31.6454 0.69021 30.243 33.048 Std Error uses a pooled estimate of error variance
319
Appendix H. Mortar Expansion in Limewater Statistical Analysis
320
Table H.1 Individual Expansions in Limewater of TI Blends
TI Blends Sample ID 14d TI Blends Sample ID 14d
TI 1 0.001 TI CKD D 10% 1 0.043
TI 2 0.000 TI CKD D 10% 2 0.040
TI 3 0.002 TI CKD D 10% 3 0.046
TI 4 0.001 average 0.001 TI CKD D 10% 4 0.044 average 0.043
TI 1 0.010 TI CKD E 10% 1 0.031
TI 2 0.008 TI CKD E 10% 2 0.029
TI 3 0.007 TI CKD E 10% 3 0.030
TI 4 0.009 average 0.008 TI CKD E 10% 4 0.029 average 0.030
TI 1 0.008 TI CKD F 10% 1 0.015
TI 2 0.008 TI CKD F 10% 2 0.017
TI 3 0.008 TI CKD F 10% 3 0.017
TI 4 0.009 average 0.008 TI CKD F 10% 4 0.017 average 0.016
TI 1 0.003 TI CKD LS 20% 1 0.006
TI 2 0.005 TI CKD LS 20% 2 0.006
TI 3 0.005 TI CKD LS 20% 3 0.006
TI 4 0.005 average 0.004 TI CKD LS 20% 4 0.006 average 0.006
TI 1 0.005 TI CKD LS 20% 1 0.003
TI 2 0.004 TI CKD LS 20% 2 0.004
TI 3 0.005 TI CKD LS 20% 3 0.003
TI 4 0.005 average 0.005 TI CKD LS 20% 4 0.003 average 0.003
TI 1 0.004 TI CKD SLX 20% 1 0.002
TI 2 0.004 TI CKD SLX 20% 2 0.004
TI 3 0.004 TI CKD SLX 20% 3 0.004
TI 4 0.003 average 0.004 TI CKD SLX 20% 4 0.004 average 0.004
TI CKD LS 10% 1 0.009 TI CKD SLX 20% 1 0.005
TI CKD LS 10% 2 0.010 TI CKD SLX 20% 2 0.005
TI CKD LS 10% 3 0.010 TI CKD SLX 20% 3 0.005
TI CKD LS 10% 4 0.009 average 0.009 TI CKD SLX 20% 4 0.006 average 0.005
TI CKD LS 10% 1 0.004 TI CKD A 20% 1 0.014
TI CKD LS 10% 2 0.006 TI CKD A 20% 2 0.015
TI CKD LS 10% 3 0.004 TI CKD A 20% 3 0.014
TI CKD LS 10% 4 0.004 average 0.004 TI CKD A 20% 4 0.014 average 0.014
TI CKD SLX 10% 1 0.005 TI CKD B 20% 1 0.011
TI CKD SLX 10% 2 0.006 TI CKD B 20% 2 0.010
TI CKD SLX 10% 3 0.005 TI CKD B 20% 3 0.010
TI CKD SLX 10% 4 0.006 average 0.006 TI CKD B 20% 4 0.012 average 0.011
TI CKD SLX 10% 1 0.006 TI CKD C 20% 1 0.012
TI CKD SLX 10% 2 0.006 TI CKD C 20% 2 0.012
TI CKD SLX 10% 3 0.005 TI CKD C 20% 3 0.013
TI CKD SLX 10% 4 0.005 average 0.005 TI CKD C 20% 4 0.012 average 0.012
TI CKD A 10% 1 0.009 TI CKD D 20% 1 0.1390
TI CKD A 10% 2 0.012 TI CKD D 20% 2 0.1330
TI CKD A 10% 3 0.009 TI CKD D 20% 3 0.1260
TI CKD A 10% 4 0.009 average 0.010 TI CKD D 20% 4 0.1270 average 0.131
TI CKD B 10% 1 0.007 TI CKD D 20% 1 0.124
TI CKD B 10% 2 0.007 TI CKD D 20% 2 0.126
TI CKD B 10% 3 0.009 TI CKD D 20% 3 0.124
TI CKD B 10% 4 0.008 average 0.008 TI CKD D 20% 4 0.126 average 0.125
TI CKD C 10% 1 0.007 TI CKD E 20% 1 0.067
TI CKD C 10% 2 0.007 TI CKD E 20% 2 0.062
TI CKD C 10% 3 0.006 TI CKD E 20% 3 0.071
TI CKD C 10% 4 0.007 average 0.007 TI CKD E 20% 4 0.070 average 0.068
TI CKD D 10% 1 0.058 TI CKD F 20% 1 0.033
TI CKD D 10% 2 0.059 TI CKD F 20% 2 0.034
TI CKD D 10% 3 0.056 TI CKD F 20% 3 0.033
TI CKD D 10% 4 0.055 average 0.057 TI CKD F 20% 4 0.034 average 0.034
TI CKD D 10% 1 0.059
TI CKD D 10% 2 0.057
TI CKD D 10% 3 0.058
TI CKD D 10% 4 0.059 average 0.058
321
Oneway Analysis of 14d By Cement TI Blends
-0.01
0.01
0.03
0.05
0.07
0.09
0.11
0.13
14d
TI
TI C
KD
A 1
0%
TI C
KD
A 2
0%
TI C
KD
B 1
0%
TI C
KD
B 2
0%
TI C
KD
C 1
0%
TI C
KD
C 2
0%
TI C
KD
D 1
0%
TI C
KD
D 2
0%
TI C
KD
E 1
0%
TI C
KD
E 2
0%
TI C
KD
F 1
0%
TI C
KD
F 2
0%
TI C
KD
LS
10%
TI C
KD
LS
20%
TI C
KD
SLX
10%
TI C
KD
SLX
20%
TI Blends
Oneway Anova Summary of Fit Rsquare 0.991545 Adj Rsquare 0.990179 Root Mean Square Error 0.003338 Mean of Response 0.024043 Observations (or Sum Wgts) 116
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TI Blends 16 0.12937762 0.008086 725.6601 <.0001 Error 99 0.00110317 0.000011 C. Total 115 0.13048078
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TI 24 0.005125 0.00068 0.00377 0.00648 TI CKD A 10% 4 0.009750 0.00167 0.00644 0.01306 TI CKD A 20% 4 0.014250 0.00167 0.01094 0.01756 TI CKD B 10% 4 0.007750 0.00167 0.00444 0.01106 TI CKD B 20% 4 0.010750 0.00167 0.00744 0.01406 TI CKD C 10% 4 0.006750 0.00167 0.00344 0.01006 TI CKD C 20% 4 0.012250 0.00167 0.00894 0.01556 TI CKD D 10% 12 0.052833 0.00096 0.05092 0.05475 TI CKD D 20% 8 0.128125 0.00118 0.12578 0.13047 TI CKD E 10% 4 0.029750 0.00167 0.02644 0.03306 TI CKD E 20% 4 0.067500 0.00167 0.06419 0.07081 TI CKD F 10% 4 0.016500 0.00167 0.01319 0.01981 TI CKD F 20% 4 0.033500 0.00167 0.03019 0.03681 TI CKD LS 10% 8 0.007000 0.00118 0.00466 0.00934 TI CKD LS 20% 8 0.004625 0.00118 0.00228 0.00697 TI CKD SLX 10% 8 0.005500 0.00118 0.00316 0.00784 TI CKD SLX 20% 8 0.004375 0.00118 0.00203 0.00672 Std Error uses a pooled estimate of error variance
322
Table H.2 Individual Expansions in Limewater of TII Blends
TII Blends Sample 14d
TII 1 0.0070
TII 2 0.0080
TII 3 0.0080
TII 4 0.0080 average 0.008
TII 1 0.0040
TII 2 0.0060
TII 3 0.0050
TII 4 0.0060 average 0.005
TII CKD LS 10% 1 0.0060
TII CKD LS 10% 2 0.0050
TII CKD LS 10% 3 0.0050
TII CKD LS 10% 4 0.0060 average 0.005
TII CKD SLX 10% 1 0.0080
TII CKD SLX 10% 2 0.0070
TII CKD SLX 10% 3 0.0080
TII CKD SLX 10% 4 0.0070 average 0.008
TII CKD A 10% 1 0.0140
TII CKD A 10% 2 0.0140
TII CKD A 10% 3 0.0150
TII CKD A 10% 4 0.0150 average 0.015
TII CKD B 10% 1 0.0110
TII CKD B 10% 2 0.0110
TII CKD B 10% 3 0.0100
TII CKD B 10% 4 0.0120 average 0.011
TII CKD C 10% 1 0.0120
TII CKD C 10% 2 0.0120
TII CKD C 10% 3 0.0110
TII CKD C 10% 4 0.0110 average 0.012
TII CKD D 10% 1 0.0170
TII CKD D 10% 2 0.0170
TII CKD D 10% 3 0.0190
TII CKD D 10% 4 0.0160 average 0.017
TII CKD E 10% 1 0.0210
TII CKD E 10% 2 0.0230
TII CKD E 10% 3 0.0210
TII CKD E 10% 4 0.0220 average 0.022
TII CKD F 10% 1 0.0190
TII CKD F 10% 2 0.0170
TII CKD F 10% 3 0.0180
TII CKD F 10% 4 0.0180 average 0.018
TII CKD LS 20% 1 0.0050
TII CKD LS 20% 2 0.0060
TII CKD LS 20% 3 0.0050
TII CKD LS 20% 4 0.0050 average 0.005
TII CKD SLX 20% 1 0.0050
TII CKD SLX 20% 2 0.0060
TII CKD SLX 20% 3 0.0060
TII CKD SLX 20% 4 0.0060 average 0.006
TII CKD A 20% 1 0.0150
TII CKD A 20% 2 0.0150
TII CKD A 20% 3 0.0140
TII CKD A 20% 4 0.0150 average 0.015
TII CKD B 20% 1 0.0130
TII CKD B 20% 2 0.0130
TII CKD B 20% 3 0.0120
TII CKD B 20% 4 0.0110 average 0.012
TII CKD C 20% 1 0.0140
TII CKD C 20% 2 0.0140
TII CKD C 20% 3 0.0160
TII CKD C 20% 4 0.0150 average 0.015
TII CKD D 20% 1 0.0490
TII CKD D 20% 2 0.0470
TII CKD D 20% 3 0.0490
TII CKD D 20% 4 0.0500 average 0.049
TII CKD E 20% 1 0.0550
TII CKD E 20% 2 0.0530
TII CKD E 20% 3 0.0520
TII CKD E 20% 4 0.0530 average 0.053
TII CKD F 20% 1 0.0280
TII CKD F 20% 2 0.0290
TII CKD F 20% 3 0.0290
TII CKD F 20% 4 0.0290 average 0.029
323
Oneway Analysis of 14d By Cement TII Blends
0
0.01
0.02
0.03
0.04
0.05
0.06
14d
TII
TII C
KD
A 1
0%
TII C
KD
A 2
0%
TII C
KD
B 1
0%
TII C
KD
B 2
0%
TII C
KD
C 1
0%
TII C
KD
C 2
0%
TII C
KD
D 1
0%
TII C
KD
D 2
0%
TII C
KD
E 1
0%
TII C
KD
E 2
0%
TII C
KD
F 1
0%
TII C
KD
F 2
0%
TII C
KD
LS
10%
TII C
KD
LS
20%
TII C
KD
SLX
10%
TII C
KD
SLX
20%
TII Blends
Oneway Anova Summary of Fit Rsquare 0.99626 Adj Rsquare 0.995172 Root Mean Square Error 0.000949 Mean of Response 0.016861 Observations (or Sum Wgts) 72
Analysis of Variance Source DF Sum of Squares Mean Square F Ratio Prob > F TII Blends 16 0.01318511 0.000824 915.6327 <.0001 Error 55 0.00004950 9e-7 C. Total 71 0.01323461
Means for Oneway Anova Level Number Mean Std Error Lower 95% Upper 95% TII 8 0.006500 0.00034 0.00583 0.00717 TII CKD A 10% 4 0.014500 0.00047 0.01355 0.01545 TII CKD A 20% 4 0.014750 0.00047 0.01380 0.01570 TII CKD B 10% 4 0.011000 0.00047 0.01005 0.01195 TII CKD B 20% 4 0.012250 0.00047 0.01130 0.01320 TII CKD C 10% 4 0.011500 0.00047 0.01055 0.01245 TII CKD C 20% 4 0.014750 0.00047 0.01380 0.01570 TII CKD D 10% 4 0.017250 0.00047 0.01630 0.01820 TII CKD D 20% 4 0.048750 0.00047 0.04780 0.04970 TII CKD E 10% 4 0.021750 0.00047 0.02080 0.02270 TII CKD E 20% 4 0.053250 0.00047 0.05230 0.05420 TII CKD F 10% 4 0.018000 0.00047 0.01705 0.01895 TII CKD F 20% 4 0.028750 0.00047 0.02780 0.02970 TII CKD LS 10% 4 0.005500 0.00047 0.00455 0.00645 TII CKD LS 20% 4 0.005250 0.00047 0.00430 0.00620 TII CKD SLX 10% 4 0.007500 0.00047 0.00655 0.00845 TII CKD SLX 20% 4 0.005750 0.00047 0.00480 0.00670 Std Error uses a pooled estimate of error variance