Transcript
Page 1: Celwave 497 VHF Duplexer SN 13677 20190513 · 5/13/2019  · Abs dB Ch1 Ch2 1:Transmission /M Log Mag 20.0 dB/ Ref -40.00 dB 2:Reflection /M Log Mag 5.0 dB/ Ref 0.00 dB Start 145.025

S/N: 13677Low Pass Branch Testing After Repair & Tuning

Celwave Model 497 VHF Duplexer

Isolation: 103.43 dBInsertion Loss: 1.20 dB

Return Loss: 36.79 dBVSWR: 1.029:1Match Efficiency: 99.979%

Services by DuplexerRepair(334) 444-6796

(A division of Alabama Broadcast Services, LLC)www.DuplexerRepair.com

1:Mkr (MHz) dB 2:Mkr (MHz) dB

1: 146.03 -1.20 1> 146.03 -36.79

2> 146.62 -103.43 2: 146.62 -0.13

-140

-120

-100

-80

-60

-20

0

20

Abs

dB

Ch1

Ch2

1:Transmission /M Log Mag 20.0 dB/ Ref -40.00 dB

2:Reflection /M Log Mag 5.0 dB/ Ref 0.00 dB

Start 145.025 MHz Stop 147.625 MHzStart 145.025 MHz Stop 147.625 MHz

1

2Celwave SN: 13677 LPB

2019-05-13 15:37:24

1

2

Ch1:Mkr2 146.625 MHz

-103.43 dB

1

2

Ch2:Mkr1 146.025 MHz

-36.79 dB

Page 2: Celwave 497 VHF Duplexer SN 13677 20190513 · 5/13/2019  · Abs dB Ch1 Ch2 1:Transmission /M Log Mag 20.0 dB/ Ref -40.00 dB 2:Reflection /M Log Mag 5.0 dB/ Ref 0.00 dB Start 145.025

S/N: 13677High Pass Branch Testing After Repair & Tuning

Celwave Model 497 VHF Duplexer

Isolation: 103.25 dBInsertion Loss: 0.82 dB

Return Loss: 31.99 dBVSWR: 1.052:1Match Efficiency: 99.937%

Services by DuplexerRepair(334) 444-6796

(A division of Alabama Broadcast Services, LLC)www.DuplexerRepair.com

1:Mkr (MHz) dB 2:Mkr (MHz) dB

1> 146.03 -103.25 1: 146.03 -0.20

2: 146.62 -0.82 2> 146.62 -31.99

-140

-120

-100

-80

-60

-20

0

20

Abs

dB

Ch1

Ch2

1:Transmission /M Log Mag 20.0 dB/ Ref -40.00 dB

2:Reflection /M Log Mag 5.0 dB/ Ref 0.00 dB

Start 145.025 MHz Stop 147.625 MHzStart 145.025 MHz Stop 147.625 MHz

12

Celwave SN: 13677 HPB

2019-05-13 15:44:45

1

2

Ch1:Mkr1 146.025 MHz

-103.25 dB1

2

Ch2:Mkr2 146.625 MHz

-31.99 dB

Page 3: Celwave 497 VHF Duplexer SN 13677 20190513 · 5/13/2019  · Abs dB Ch1 Ch2 1:Transmission /M Log Mag 20.0 dB/ Ref -40.00 dB 2:Reflection /M Log Mag 5.0 dB/ Ref 0.00 dB Start 145.025

S/N: 13677Service & Repair Photos

Celwave Model 497 VHF Duplexer

Services by DuplexerRepair(334) 444-6796

(A division of Alabama Broadcast Services, LLC)www.DuplexerRepair.com

Loop/notch assembly with damaged threads on notch adjustment rod. Could not be adjusted/tuned prior to repair.

Page 4: Celwave 497 VHF Duplexer SN 13677 20190513 · 5/13/2019  · Abs dB Ch1 Ch2 1:Transmission /M Log Mag 20.0 dB/ Ref -40.00 dB 2:Reflection /M Log Mag 5.0 dB/ Ref 0.00 dB Start 145.025

S/N: 13677Service & Repair Photos

Celwave Model 497 VHF Duplexer

Services by DuplexerRepair(334) 444-6796

(A division of Alabama Broadcast Services, LLC)www.DuplexerRepair.com

Amount of metal fragments which came out of female threads upon re-tapping/re-running threads. Most of this came from the threaded notch tuning rod, but some were from the female threads themselves.

Threads on notch/reject tuning rod re-run and polished. After thread repairs, notch/reject tuning rod would thread through entire range with two fingers.

Notch/reject tuning rod threaded fully into cavity, as seen from lower end of cylinder.


Top Related