Download - Catalogue Omega Air 2011
Product catalogue 2011
Compressed air
treatment
2
Faithfully trying to serve you.
The missing piece of
Your business !Your business !
Erik KrušecSales manager - World market
Telephone: +386 1 200 68 60
Mobile: +386 30 362 140
Fax: +386 1 200 68 53
E-mail: [email protected]
Špela RemicSales & technical support
Telephone: +386 1 200 68 61
Fax: +386 1 200 68 53
E-mail: [email protected]
Tilen LovrečičSales & technical support
Telephone: +386 1 200 68 62
Mobile: +386 30 362 180
Fax: +386 1 200 68 53
E-mail: [email protected]
Luka TršarSales & technical support
Telephone: +386 1 200 68 13
Mobile: +386 30 362 190
Fax: +386 1 200 68 53
E-mail: [email protected]
www.omega-air.si 3
Certifi cates
Edvard Sojer general manager
Alojz Dobnikar technical manager
Dear customers,
The air is everywhere. It is the essential part of our life. Like the people, who needs high quality air for our breathing, technology processes, pharmacy, industry,... needs it to.
We became experts in this range of air technology. Continually investing to new technologies, research & development, and quality processes can give only great results. ISO and ASME certifi cates are only one proof. Our numerous satisfi ed customers are the others.
Our goals remains the same; delivering top quality products to our customers.
ISO 9001:2008
CE-PED-HCE-PED-H1
4
PDI 16 MDM 60 MDM 60C MDM 60E
MCD AOK 16B AOK 20B EMD 12TD16S
B P R M S AH2
A2
TD16m
MDA 60
ECD-B
ALUMINIUM FILTERS FOR INDUSTRIAL APPLICATIONS
AF series 16 barpage 8
FILTERS FOR INDUSTRIAL APPLICATIONS
www.omega-air.si 5
CARBON STEEL INDUSTRIAL FILTERS
BF series 16 barpage 10
ALUMINIUM INDUSTRIAL FILTERS
CF series 20 barpage 12
ALUMINIUM INDUSTRIAL FILTERS
DF series 16 barpage 14
CAST ALUMINIUM HIGH PRESSURE FILTERS
HF series 50 barpage 32
ALUMINIUM HIGH PRESSURE FILTERS
AHP series 64 barpage 34
CARBON STEEL HIGH PRESSURE FILTERS
CHP series 100, 250, 400 barpage 36
6
FILTERS FOR SPECIAL APPLICATIONSFILTERS FOR STERILE AND PROCESS APPLICATIONS
STAINLESS STEEL PROCESS FILTERS
PF series 16 bar
HIGH PRESSURE STAINLESS STEEL PROCESS FILTERS
HPF series 50 bar
STAINLESS STEEL STERILE FILTERS
SF series 16 bar
STAINLESS STEEL STERILE FILTERS
SPF series 16 bar
page 38
page 40
page 42
page 44
VACUUM PUMP PROTECTION FILTERS
P-VAC series 20-2000 mbarpage 46
MEDICAL VACUUM FILTERS
M-VAC series 20-2000 mbarpage 47
COMPRESSED NATURAL GAS FILTERS
CNG series 20 barpage 48
PAINTING AIR FILTERS
PAINT series 16 barpage 50
BREATHING AIR FILTERS
B-AIR series 16 barpage 51
SYLICONE FREE FILTERS
AFs series 16 barpage 52
www.omega-air.si 7
CONDENSATE DRAINS
ELECTRONIC VOLUME CONTROLLED CONDENSATE DRAINS
ECD-B seriespage 22
ELECTRONIC VOLUME CONTROLLED CONDENSATE DRAINS
EMD12 series 16 barpage 24
ELECTRONIC TIMER CONTROLLED CONDENSATE DRAINS
TD16M series 16 barpage 25
ELECTRONIC TIMER CONTROLLED CONDENSATE DRAINS
TD16S series 16 barpage 26
MECHANICAL AUTOMATIC CONDENSATE DRAINS
AOK 20B series 20 barpage 27
MECHANICAL AUTOMATIC CONDENSATE DRAINS
AOK16B series 16 barpage 28
MECHANICAL MANUAL CONDENSATE DRAINS
MCD series 16 barpage 28
WATER-OIL SEPARATORS
WATER-OIL SEPARATORS FOR COMPRESSED AIR
WOS-M seriespage 29
CYCLONE CONDENSATE SEPARATORS
CKL-B series 16 barpage 18
CYCLONE CONDENSATE SEPARATORS
CS series 16 barpage 20
STAINLESS STEEL CYCLONE CONDENSATE SEPARATORS
CS-SS series 16 barpage 21
CONDENSATE SEPARATORS
WATER-OIL SEPARATORS FOR COMPRESSED AIR
WOS seriespage 30
8
B
80
C
AD
R 1/2’’
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,38 0,50 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
Filter housing
model
Pipe size Flow rate at 7 bar(g), 20°C Dimensions [mm] Mass
inch Nm3/h scfm A B C D kg
AF 0056 3/8’’ 60 35 187 88 20 60 0,7
AF 0076 1/2’’ 78 46 187 88 20 60 0,7
AF 0106 3/4’’ 120 70 257 88 20 80 0,8
AF 0186 1’’ 198 116 263 125 32 100 1,8
AF 0306 1’’ 335 197 363 125 32 120 2,5
AF 0476 1 1/2’’ 510 300 461 125 32 140 2,5
AF 0706 1 1/2’’ 780 459 640 125 32 160 3,2
AF 0946 2’’ 1000 588 684 163 43 520 5,1
AF 1506 2’’ 1500 882 935 163 43 770 7,1
AF 1756 2 1/2’’ 1680 990 935 163 43 770 6,9
AF 2006 3 2160 1270 795 240 59 630 12,9
AF 2406 3 2760 1620 1000 240 59 780 14,0
Compressed air fi lters AF Series are used for effi cient removal of solid particles, water, oil vapours, taste and odours from compressed air in industrial applications.
The type and size of fi lters depends of compressed air fl ow, type and quantity of polution.
Available optional equipment is described on picture below.
- max. operating pressure: 16 bar (232 psi)- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
Standard equipment includes fi lter housing and fi lter cartridge.
ECD-B
OPTIONAL EQUIPMENT
PDI 16 MDM 60 MDM 60C MDM 60E MDA 60
MCD AOK 16B TD16SAOK 20B EMD12
sight glass - option
aluminium compressed air filters - 16 bar
16 bar
1,5 ÷ 65 °C
60 ÷ 2.760 m3/h
industrial applications
TD16m
Cartridge size
Flow rate at 7 bar(g), 20°C Max. oper.
pressure [bar/psi]
Filter’s housing
B sintered
15 μm
Pprefi lter
3 μm
Rprefi lter
1 μm
Mmicrofi lter
0,1 μm
Smicrofi lter
0,01 μm
Aactive
carbon
A2
adsorption(act. carb.)
H2
catalyst(hopcalite)m3/h SCFM
06050 60 35 16/232 AF 0056 06050 B15 06050 P 06050 R 06050 M 06050 S 06050 A - -
07050 78 46 16/232 AF 0076 07050 B15 07050 P 07050 R 07050 M 07050 S 07050 A 07050 A2 07050 H2
14050 120 70 16/232 AF 0106 14050 B15 14050 P 14050 R 14050 M 14050 S 14050 A 14050 A2 14050 H2
12075 198 116 16/232 AF 0186 12075 B15 12075 P 12075 R 12075 M 12075 S 12075 A 12075 A2 12075 H2
22075 335 197 16/232 AF 0306 22075 B15 22075 P 22075 R 22075 M 22075 S 22075 A 22075 A2 22075 H2
32075 510 300 16/232 AF 0476 32075 B15 32075 P 32075 R 32075 M 32075 S 32075 A 32075 A2 32075 H2
50075 780 459 16/232 AF 0706 50075 B15 50075 P 50075 R 50075 M 50075 S 50075 A 50075 A2 50075 H2
51090 1000 588 16/232 AF 0946 51090 B15 51090 P 51090 R 51090 M 51090 S 51090 A - -
76090 1500 882 16/232 AF 1506 76090 B15 76090 P 76090 R 76090 M 76090 S 76090 A - -
76090 1680 990 16/232 AF 1756 76090 B15 76090 P 76090 R 76090 M 76090 S 76090 A - -
51140 2160 1270 16/232 AF 2006 51140 B15 51140 P 51140 R 51140 M 51140 S 51140 A - -
75140 2760 1620 16/232 AF 2406 75140 B15 75140 P 75140 R 75140 M 75140 S 75140 A - -
B P R M S A A2 H2
solid particle size purifi cation: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron - 0,1 0,1
quality class - solids (ISO 8573-1) 4 3 2 1 1 - 1 1
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005/0,005
quality class - oils (ISO 8573-1) - - - 2 1 1 0/1 -
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3 see spec. see spec.
change fi lter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 * 6 months * 6 months 6 months
fi lter material sintered brass acrile fi bres, celulose borosilicate micro fi bres active
carbon
activated carbon,
borosilicate micro fi bres
hopcalite, borosilicate micro fi bres
pleated version - + + + + - + +
wrapped version - + + + + + - -
sintered version + - - - - - - -
min. operating temperature (°C / °F) 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35
max. operating temperature (°C / °F) 65 / 149 65 / 149 65 / 149 65 / 149 65 / 149 45 / 113 45 / 113 45 / 113
Omega Air fi lter cartridge production includes 8 fi ltration stages (B, P, R, M, S and A), which are designed to remove particulates, water, oil vapours, taste and odours from compressed air. Two stage fi lter elements are developed: A2 for high effi cient removal of oil vapours and odours and H2 for high effi cint removal of carbon monoxide from compressed air.
The design of fi lter media ensures the eff ective and effi cient removal most of contaminates in compressed air systems. For CO and CO2 removal please contact us.
Materials are corrosion-proof and suitable for most of applications.
The fi lter and cartridge size is determined by the compressed air fl ow. They are all designed for operation pressure up to 16 bar (232 psi).
* Filter elements ’’A, A2, H2’’ must be changed periodically to suit application but at least every 6 months. Activated carbon fi lters must not operate in oil saturated conditions.
patented
patented
www.omega-air.si 9
AF filter cartridges
10
SIZES:
BF 0240BF 0300BF 0450 BF 0600 BF 0900
SIZES:
BF 1200BF 1500BF 1800 BF 2500 BF 3000
min
.650
mm
A
C m
inE
BøD
min
.200
mm
C
A
B
øD
Filter
model
Connection
size
Flow rate at 7 bar(g), 20°C Dimensions [mm] Dimensions [inch] Mass No. of car-
tridgesDN Nm3/h SCFM A B C D E A B C D E kg lb
BF 0240 80 2200 1294 1170 450 1645 219,1 177 46 18 65 8 1/2 25 1/2 61 134 1
BF 0300 100 3150 1853 1340 560 1760 323,9 227 52 1/2 22 69 1/2 13 9 115 253 2
BF 0450 125 4700 2765 1360 560 1780 323,9 227 53 1/2 22 70 13 9 123 271 3
BF 0600 150 6300 3706 1425 620 1810 368 265 56 24 1/2 71 1/2 14 1/2 10 1/2 151 333 4
BF 0900 150 9400 5530 1480 680 1850 419 650 58 1/2 26 1/2 73 16 1/2 11 218 480 6
BF 1200 200 12550 7382 1835 792 510 508 280 72 1/2 31 20 20 - 320 705 8
BF 1500 200 15700 9235 1880 918 535 609,6 - 74 36 21 24 - 455 1003 10
BF 1800 250 18850 11088 1950 955 555 609,6 - 76 1/2 37 1/2 22 24 - 500 1102 12
BF 2500 250 25100 14765 2060 1042 645 711,2 - 81 41 25 1/2 28 - 590 1300 16
BF 3000 300 31400 18470 2130 1085 680 711,2 - 84 42 1/2 26 1/2 28 - 684 1508 20
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,53 0,65 0,76 0,84 0,92 1,00 1,07 1,13 1,19 1,25 1,31 1,36 1,41 1,46 1,51
BF Welded compressed air fi lters are used for compressed air fi ltration in large capacity compressed air systems. Ten diff erent sizes covers a wide fl ow range.
BF Filters are made of quality steel in accordance with Pressure Equipment Directive PED 97/23/CE. Number of fi lter cartridges depends of fi lter size.
There are 6 fi ltration stages available. Diff erential pressure indicators and Condensate drains can be optionally mounted on all types of BF fi lters. Filters are protected against corrosion by RAL colour painting. On customer’s request, we can off er epoxy painting or hot-dipped galvanizing.
- max. operating pressure: 16 bar (232 psi)- operating temperature range: 1,5 to 65 °C (35 to 149 °F)- fi lter cartridge type: 76090
welded compressed air filters - 16 bar
16 bar
1,5 ÷ 65 °C
2.200 ÷ 31.400 Nm3/h
industrial applications
www.omega-air.si 11
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon fi lters must not operate in oil saturated conditions.
** 45 °C / 139°F for active carbon cartridges!
Cartridge size
Flow rate at 7 bar(g), 20°C
Max. oper. pressure [bar/psi]
Max. operating
temp. [°C/°F]
Filter’s housing
B sintered
15 μm
Pprefi lter
3 μm
Rprefi lter
1 μm
Mmicrofi lter
0,1 μm
Smicrofi lter
0,01 μm
Aactive
carbonm3/h SCFM
76090 1500 882 16/232 65/149 ** All 76090 B15 76090 P 76090 R 76090 M 76090 S 76090 A
B P R M S A
solid particle size purifi cation: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
quality class - solids (ISO 8573-1) 4 3 2 1 1 -
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005 / 0,005
quality class - oils (ISO 8573-1) - - - 2 1 1
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change fi lter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
fi lter material sintered brass acrile fi bres, celulose borosilicate micro fi bres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
BF filter cartridgesOmega Air fi lter cartridge production includes 6 fi ltration stages (B, P, R, M, S and A), which are designed to remove particulates, water, oil vapours, taste and odours from compressed air.
The design of fi lter media ensures the eff ective and effi cient removal most of contaminates in compressed air systems. Note that these fi lters will not remove carbon monoxide or carbon dioxide.
All materials are suitable for operation in the temperature range from 1,5 to 65 °C (35 to 149 °F). They are corrosion-proof and suitable for most of applications.
The fi lter and cartridge size is determined by the compressed air fl ow. They are all designed for operation pressure up to 16 bar (232 psi).
12
B
80
C
AD
R 1/2’’
Compressed air fi lters CF Series are used for effi cient removal of solid particles, water, oil vapours, taste and odours from compressed air in industrial applications.
The type and size of fi lters depends of compressed air fl ow, type and quantity of polution.
- max. operating pressure: 20 bar (290 psi)
- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
aluminium compressed air filters - 20 bar
20 bar
1,5 ÷ 65 °C
72 ÷ 2.760 m3/h
industrial applications
Filter model Connection
Flow rate at 7 bar(g), 20°C Dimensions [mm]
Mass
[kg]
Operating
pressure
[bar]Nm3/h scfm A B C D
CF 20 3/8’’ 72 42 187 88 20 80 0,7 20
CF 21 1/2’’ 96 56 256 88 20 80 0,8 20
CF 30 1/2’’ 150 88 278 106 25 100 1,3 20
CF 31 3/4’’ 216 127 278 106 25 100 1,3 20
CF 40 1’’ 282 166 252 125 32 120 2,1 20
CF 41 1’’ 360 212 352 125 32 140 2,4 20
CF 42 1 1/4’’ 432 254 352 125 32 140 2,4 20
CF 43 1 1/2’’ 510 300 450 125 32 160 3,2 20
CF 44 1 1/2’’ 750 441 450 125 32 160 3,2 20
CF 50 2’’ 888 522 605 160 43 180 5,1 20
CF 51 2’’ 1176 692 605 160 43 180 5,1 20
CF 52 2 1/2’’ 1440 847 685 160 43 200 6,3 20
CF 60 3’’ 1968 1158 1070 240 60 300 12,9 20
CF 61 3’’ 2760 1624 1070 240 60 300 12,9 20
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232 247 261 276 290
Correction factor 0,38 0,5 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13 2,25 2,38 2,50 2,63
www.omega-air.si 13
Filter’s
housing
Flow rate at 7 bar(g), 20°C
Max. operat-
ing pressure
[bar/psi]
Max.
operating
temp. [°C/°F]
B
sintered
15 μm
P
prefi lter
3 μm
R
prefi lter
1 μm
M
microfi lter
0,1 μm
S
microfi lter
0,01 μm
A
active
carbonm3/h SCFM
CF 20 72 42 20/290 65/149 ** 20 CB 20 CP 20 CR 20 CM 20 CS 20 CA
CF 21 96 56 20/290 65/149 ** 21 CB 21 CP 21 CR 21 CM 21 CS 21 CA
CF 30 150 88 20/290 65/149 ** 30 CB 30 CP 30 CR 30 CM 30 CS 30 CA
CF 31 216 127 20/290 65/149 ** 31 CB 31 CP 31 CR 31 CM 31 CS 31 CA
CF 40 282 166 20/290 65/149 ** 40 CB 40 CP 40 CR 40 CM 40 CS 40 CA
CF 41 360 212 20/290 65/149 ** 41 CB 41 CP 41 CR 41 CM 41 CS 41 CA
CF 42 432 254 20/290 65/149 ** 42 CB 42 CP 42 CR 42 CM 42 CS 42 CA
CF 43 510 300 20/290 65/149 ** 43 CB 43 CP 43 CR 43 CM 43 CS 43 CA
CF 44 750 441 20/290 65/149 ** 44 CB 44 CP 44 CR 44 CM 44 CS 44 CA
CF 50 888 522 20/290 65/149 ** 50 CB 50 CP 50 CR 50 CM 50 CS 50 CA
CF 51 1176 692 20/290 65/149 ** 51 CB 51 CP 51 CR 51 CM 51 CS 51 CA
CF 52 1440 847 20/290 65/149 ** 52 CB 52 CP 52 CR 52 CM 52 CS 52 CA
CF 60 1968 1158 20/290 65/149 ** 60 CB 60 CP 60 CR 60 CM 60 CS 60 CA
CF 61 2760 1624 20/290 65/149 ** 61 CB 61 CP 61 CR 61 CM 61 CS 61 CA
B P R M S A
solid particle size purifi cation: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
quality class - solids (ISO 8573-1) 4 3 2 1 1 -
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005 / 0,005
quality class - oils (ISO 8573-1) - - - 2 1 1
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 <90 / 1,3 120 / 1,74
change fi lter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
fi lter material sintered brass acrile fi bres, celulose borosilicate micro fi bres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
CF Filter cartridge range includes 6 fi ltration stages (B, P, R, M, S and A), which are designed to remove particulates, water, oil vapours, taste and odours from compressed air.
The design of CF Filter media ensures the eff ective and effi cient removal most of contaminates from compressed air systems. Note that these fi lters will not remove carbon monoxide or carbon dioxide.
Threaded connection of fi lter cartridge end cap ensures reliable fi tting into fi lter head.
All materials are suitable for operation in the temperature range from 1,5 to 65 °C (35 to 149 °F). They are corrosion-proof and suitable for most of applications.
The fi lter and cartridge size is determined by the compressed air fl ow. They are all designed for operation pressure up to 20 bar (290 psi).
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon fi lters must not operate in oil saturated conditions.
** 45 °C / 139°F for active carbon cartridges!
CF filter cartridges
14
B
C
AD
R 1/2’’
DF fi lter housings sre designed for high effi cient removal of solid particles, water, oil aerosols, hydrocarbons and odour vapours from compressed air systems.
To meet the required compressed air quality appropriate fi lter element (B, P, R, M, S, A) must be installed into fi lter housing. - max. operating pressure: 16 bar (232 psi)- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
aluminium compressed air filters - 16 bar
16 bar
1,5 ÷ 65 °C
60 ÷ 2.760 m3/h
industrial applications
Filter model Connection
Flow rate at 7 bar(g), 20°C Dimensions [mm]
Mass
[kg]Nm3/h scfm A B C D
DF 0056 3/8’’ 60 35 187 88 20 60 0,7
DF 0076 1/2’’ 78 46 187 88 20 60 0,7
DF 0106 3/4’’ 120 70 257 88 20 80 0,8
DF 0186 1’’ 198 116 263 125 32 100 1,8
DF 0306 1’’ 335 197 363 125 32 120 2,5
DF 0476 1 1/2’’ 510 300 461 125 32 140 2,5
DF 0706 1 1/2’’ 780 459 640 125 32 160 3,2
DF 0946 2’’ 1000 588 684 163 43 520 5,1
DF 1506 2’’ 1500 882 935 163 43 770 7,1
DF 1756 2 1/2’’ 1680 990 935 163 43 770 6,9
DF 2006 3’’ 2160 1270 795 240 59 630 12,9
DF 2406 3’’ 2760 1620 1000 240 59 780 14,0
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,38 0,5 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
ECD-B
OPTIONAL EQUIPMENT
PDI 16 MDM 60 MDM 60C MDM 60E MDA 60
MCD AOK 16B TD16SAOK 20B EMD12
sight glass - option
TD16m
www.omega-air.si 15
Cartridge size
Flow rate at 7 bar(g), 20°C
Max. oper. pressure [bar/psi]
Filter’s housing
B sintered
15 μm
Pprefi lter
3 μm
Rprefi lter
1 μm
Mmicrofi lter
0,1 μm
Smicrofi lter
0,01 μm
Aactive
carbon
A2
adsorption(act. carb.)
H2
catalyst(hopcalite)m3/h SCFM
06050 60 35 16/232 AF 0056 06050 B15 06050 P 06050 R 06050 M 06050 S 06050 A - -
07050 78 46 16/232 AF 0076 07050 B15 07050 P 07050 R 07050 M 07050 S 07050 A 07050 A2 07050 H2
14050 120 70 16/232 AF 0106 14050 B15 14050 P 14050 R 14050 M 14050 S 14050 A 14050 A2 14050 H2
12075 198 116 16/232 AF 0186 12075 B15 12075 P 12075 R 12075 M 12075 S 12075 A 12075 A2 12075 H2
22075 335 197 16/232 AF 0306 22075 B15 22075 P 22075 R 22075 M 22075 S 22075 A 22075 A2 22075 H2
32075 510 300 16/232 AF 0476 32075 B15 32075 P 32075 R 32075 M 32075 S 32075 A 32075 A2 32075 H2
50075 780 459 16/232 AF 0706 50075 B15 50075 P 50075 R 50075 M 50075 S 50075 A 50075 A2 50075 H2
51090 1000 588 16/232 AF 0946 51090 B15 51090 P 51090 R 51090 M 51090 S 51090 A - -
76090 1500 882 16/232 AF 1506 76090 B15 76090 P 76090 R 76090 M 76090 S 76090 A - -
76090 1680 990 16/232 AF 1756 76090 B15 76090 P 76090 R 76090 M 76090 S 76090 A - -
51140 2160 1270 16/232 AF 2006 51140 B15 51140 P 51140 R 51140 M 51140 S 51140 A - -
75140 2760 1620 16/232 AF 2406 75140 B15 75140 P 75140 R 75140 M 75140 S 75140 A - -
B P R M S A A2 H2
solid particle size purifi cation: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron - 0,1 0,1
quality class - solids (ISO 8573-1) 4 3 2 1 1 - 1 1
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005/0,005
quality class - oils (ISO 8573-1) - - - 2 1 1 0/1 -
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3 see spec. see spec.
change fi lter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 * 6 months * 6 months 6 months
fi lter material sintered brass acrile fi bres, celulose borosilicate micro fi bres active
carbon
activated carbon,
borosilicate micro fi bres
hopcalite, borosilicate micro fi bres
pleated version - + + + + - + +
wrapped version - + + + + + - -
sintered version + - - - - - - -
min. operating temperature (°C / °F) 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35 1,5 / 35
max. operating temperature (°C / °F) 65 / 149 65 / 149 65 / 149 65 / 149 65 / 149 45 / 113 45 / 113 45 / 113
DF filter cartridgesOmega Air fi lter cartridge production includes 6 fi ltration stages (B, P, R, M, S and A), which are designed to remove particulates, water, oil vapours, taste and odours from compressed air. Two stage fi lter elements are developed: A2 for high effi cient removal of oil vapours and odours and H2 for high effi cint removal of carbon monoxide from compressed air.
The design of fi lter media ensures the eff ective and effi cient removal most of contaminates in compressed air systems. Note that these fi lters will not remove carbon monoxide or carbon dioxide.
Materials are corrosion-proof and suitable for most of applications.
The fi lter and cartridge size is determined by the compressed air fl ow. They are all designed for operation pressure up to 16 bar (232 psi).
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon fi lters must not operate in oil saturated conditions.
16
MDM 60, MDM 60E, MDM 60C - Pressure drop indicators
The Magnetic pressure drop indicator MDM60 is available in three versions:- basic version MDM 60- electonic version MDM 60E (with LED alarm light for cartridge changing)- voltage-free dry contact version MDM 60C for remote alarm
Technical data
- green area: pressure drop 0 - 0,6 bar (0 - 8,7 psi) - red area: pressure drop 0,6 - 0,9 bar (8,7 - 13 psi) - max. operating pressure: 16 bar (232 psi) - operating temperature range: 1,5 to 65 °C (35 to 149 °F)
MDA 60 - Pressure drop indicator
Pressure drop indicator MDA 60 is used to accurately display the pressure drop across the fi lter. The housing is made of aluminium alloy, which is available either in white or aluminium colour. On a special customer’s request it can also be painted in any colour from RAL list.
Technical data - max. operating pressure: 16 bar (232 psi)- operating temperature range: 1,5 to 65 °C (35 to 149 °F)- measuring range: +/- 2 bar (+/- 29 psi)
PDI 16 - Pressure drop indicator
PDI 16 saves compressed air energy by indicating when the fi lter element needs to be changed. If the fi lter element is clean, the indicator remains green. It changes to red when the fi lter is clogged and should be changed.
Technical data - green area: pressure drop 0 - 0,6 bar (0 - 8,7 psi)- red area: pressure drop 0,6 - 0,9 bar (8,7 - 13 psi)- max. operating pressure: 16 bar (232 psi)- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
MDM 60 MDM 60E MDM 60C
equipment for compressed air filters
equipment for industrial applications
www.omega-air.si 17
AK - Assembly kit for fi lters
It is used for assembling of two, three or more fi lters together.
It includes supporting elements, which can be easily mounted to the walls or other elements.
Universal usage
Construction of assenbly kit is universal and it can be used for any fi lter types, including fi lters of other world producers.
18
Effi cient removal of condensate from a compressed air system has several advantages: extended life of compressed air tools, improved lubrication of all pneumatic components, improved painting processes, reduced corrosion, and elimination of freezing.
These advantages can all be achieved with the installation of Omega Air CKL-B Cyclone separators. This high-effi ciency separators will remove condensed water droplets, with a very low pressure drop. They also provide added protection and improved performance for dryers and fi lters.
Typically, water separators are installed downstream of after coolers, air receivers, refrigerant dryers and strategic points in pipe work installation.
Standard equipment includes automatic condensate drain AOK 16B.
- max. operating pressure: 16 bar (232 psi)- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,53 0,65 0,76 0,84 0,92 1,00 1,07 1,13 1,19 1,25 1,31 1,36 1,41 1,46 1,51
Model
Connection
size
Flow rate at 7 bar(g), 20°C Dimensions [mm] Dimensions [inch] Mass
inch Nm3/h SCFM A B C D A B C D kg lb
CKL 005 B 3/8 120 70 187 88 21 60 7 3/8 3 1/213/16 2 5/16 0,7 1,54
CKL 007 B 1/2 155 91 187 88 21 60 7 3/8 3 1/213/16 2 5/16 0,7 1,54
CKL 010 B 3/4 235 138 257 88 21 80 10 1/8 3 1/213/16 3 1/8 0,8 1,76
CKL 018 B 1 365 215 262 125 33 100 10 5/16 4 15/16 1 5/16 3 15/16 1,9 4,19
CKL 047 B 1 1/2 770 452 452 125 33 140 17 13/16 4 15/16 1 5/16 5 1/2 2,8 6,17
CKL 094 B 2 1280 753 695 163 43 520 27 3/8 6 7/16 1 11/16 20 1/2 5,3 11,7
CKL 150 B 2 1/2 2460 1447 695 163 43 520 27 3/8 6 7/16 1 11/16 20 1/2 9,2 20,3
CKL 200 B 3 2850 1677 795 240 59 630 31 5/16 9 1/2 2 5/16 24 3/4 13,4 29,5
B
C
AD R 1/2’’
aluminium condensate separators - 16 bar
16 bar
1,5 ÷ 65 °C
120 ÷ 2.850 m3/h
industrial applications
MCDAOK 16B
TD16mAOK 20B ECD-B
TD16SEMD12
www.omega-air.si 19
Benefits
Construction of aluminium cyclone separators assures high effi ciency condensate separation with low pressure drop.
Cartridge inside Cyclone separator assures reliable operation for the life of the separator, with no possibility of clogging and increased operating costs.
Condensate Cyclone separator CKL-B satisfi es all needs of applications in a wide temperature range from 1,5 to 65 °C (35 to 149 °F) and in a pressure range up to 16 bar (232 psi).
All alluminium separator bodies are coated with powder paint to eliminate corrosion.
Threaded connections are BSP according to ISO7/1 or NPT to ANSI B2.1, if supplied in North America.
air
condensate
(oil, water)
20
Model
Pipe
size
Flow rate at 7 bar(g), 20°C Dimensions [mm] Dimensions [inch] Mass
DN Nm3/min SCFM A B C D E F G H A B C D E F G H kg lb
CS 14 DN80 14 495 745 182 88,9 88,9 1/2’’ 159,0 302 35 29 5/16 7 3/16 3 1/2 3 1/21/2 6 1/4 11 7/8 1 3/8 23 50,7
CS 21 DN80 21 740 745 182 88,9 88,9 1/2’’ 159,0 302 35 29 5/16 7 3/16 3 1/2 3 1/21/2 6 1/4 11 7/8 1 3/8 23 50,7
CS 28 DN80 28,5 1000 745 182 88,9 88,9 1/2’’ 159,0 302 35 29 5/16 7 3/16 3 1/2 3 1/21/2 6 1/4 11 7/8 1 3/8 23 50,7
CS 62 DN125 62,0 2190 1041 280 133,0 133,0 1/2’’ 219,1 390 43 41 11 5 1/4 5 1/41/2 8 5/8 15 3/8 1 11/16 53 116,8
B
E
A
F
G
min
200 m
m
C
H
D
- max. operating pressure: 16 bar (232 psi)- max. operating temperature: 120 °C (248 °F)
CS Welded cyclone separators are used for the separation of particulates and condensate from large capacity compressed air systems.
They feature a combination of high effi ciency and low pressure drop. Tangential inlet connection enables perfect airfl ow, which does not require additional guidance blades with additional pressure drop.
Cyclone condensate separators are produced in accordance with Pressure Equipment Directive PED 97/23 CE.
Cyclone separators are protected against corrosion by RAL colour painting, which can be defi ned by customer. We reccomend the use of condensate drains produced by our company.
welded condensate separators - 16 bar
16 bar
1,5 ÷ 120 °C
840 ÷ 3.720 Nm3/h
industrial applications
www.omega-air.si 21
B
E
A
F
G
min
200
mm
C
H
D
A
F
E
G
E
D
CS SS Welded cyclone separators are used for the separation of particulates and condensate from large capacity compressed air systems.
They feature a combination of high effi ciency and low pressure drop. Tangential inlet connection enables perfect airfl ow, which does not require additional guidance blades with additional pressure drop.
Cyclone condensate separators are produced in accordance with Pressure Equipment Directive PED 97/23 CE. Stainless steel material prevents corrosion of built in materials.
We reccomend the use of condensate drains produced by our company.
- max. operating pressure: 16 bar (232 psi)- max. operating temperature: 120 °C (248 °F)- material: stainless steel
Model Connection
Flow rate at 7 bar(g),
20°C[Nm3/min]
Dimensions [mm] Mass
[kg]A B C D E F G H
CS SS 14 DN80 14 745 182 88,9 88,9 1/2’’ 159,0 302 35 23
CS SS 21 DN80 21 745 182 88,9 88,9 1/2’’ 159,0 302 35 23
CS SS 28 DN80 28,5 745 182 88,9 88,9 1/2’’ 159,0 302 35 23
CS SS 48 DN100 36,6 800 0 108 108 1/2’’ 219,1 460 0 42
stainless steel condensate separators - 16 bar
16 bar
1,5 ÷ 120 °C
840 ÷ 2.196 Nm3/h
process applications
22
patented
Electronic condensate drains - ECD-B series, is used for the automatic discharge of accumulated condensate from compressed air systems. The basic principle is contactless measurement of the acumulated condensate which is then discharged without the loss of valuable compressed air.
Condensate fl ow constantly fl ushes debris out of the valve. Thats why uninterrupted operating is guaranteed.
Incorrect plunger position is fi rst sign of debris blocking the valve. By detecting incorrect position, blocked plunger release procedure is started. This procedure assures safety and reliable plunger operating. No staff intervention is needed. This procedure starts automatilally.
ECD-B Series is made of aluminium housing with plastic cover, which protects electronics inside the device from outside harmful conditions.
Benefi ts
- robust aluminium housing - integrated fi lter mesh - compact design - two-way connections - eloxated housing- contactless measuring- direct acting, self cleaning valve (patented)- blocked plunger release procedure- operating diagnostic monitoring- warning LED light for ’’drain operating’’ and ’’alarm’’- AC versions (for DC version please contact Omega Air)- IP 54 electrical protection
electronic condensate drains - 16 bar
0 ÷ 16 bar
1,5 ÷ 65 °C
see table >>
condensate treatment
www.omega-air.si 23
Type ECD 15B ECD 40B ECD 90B ECD 150B
Voltage115 VAC 115 V ± 10 % 115 V ± 10 % 115 V ± 10 % 115 V ± 10 %
230 VAC 230 V ± 10 % 230 V ± 10 % 230 V ± 10 % 230 V ± 10 %
Power115 VAC 24 VA 24 VA 24 VA 24 VA
230 VAC 24 VA 24 VA 24 VA 24 VA
Frequency 50-60 Hz
Operating pressure 0-16 bar (0 - 232 psi)
Drain capacity (at 7 bar/101 psi) 15 l/h (0,0088 cfm) 40 l/h (0,023 cfm) 90 l/h (0,053 cfm) 150 l/h (0,088 cfm)
Operating temperature range 1,5 - 65 °C (35-149 °F)
Inlet connection R 1/2’’ R 1/2’’ R 1/2’’ R 1/2’’
Outlet connection R 1/8’’ R 1/8’’ R 1/8’’ R 1/8’’
Power interface 3 × 0,75 mm2 3 × 0,75 mm2 3 × 0,75 mm2 3 × 0,75 mm2
Protection class IP54 IP54 IP54 IP54
Mass [kg] 0,9 0,9 1,05 1,15
Dimensions A × B × C [mm] 120 × 82 × 125 120 × 82 × 125 120 × 82 × 135 120 × 82 × 150
Peak compressor
performance
[m3/min]
11,6 29,4 60,6 111,6
9,3 23,5 48,5 89,3
5,8 14,7 30,3 55,8
Peak dryer performance
[m3/min]
23,2 58,8 121,2 223,2
18,6 47,0 97,0 178,6
11,6 29,4 60,6 111,6
Peak fi lter performance
[m3/min]
116 294 606 1116
93 235 485 893
58 147 303 558
Compressor motor power [kW] up to 30 37-75 90-160 200-315*
Please take the relevant climate zone into account when dimensioning yours specifi c ECD-B drain series application:
Northern Europe, Canada, Northern USA, Central Asia
Central and Southern Europe, Central America
South East Asian coastal regions, Oceania, Amazon and Congo regions
* Higher motor power capacities available on request. Please contact Omega Air.
B
C
A
24
electronic condensate drains - 16 bar
condensate treatment
0 ÷ 16 bar
1,5 ÷ 65 °C
15 l/h
Type EMD12
Voltage115 VAC 115 V ± 10%
230 VAC 230 V ± 10%
Power115 VAC 24 VA
230 VAC 24 VA
Frequency 50-60 Hz
Operating pressure 0-16 bar (0 - 232 psi)
Drain capacity (at 7 bar/101 psi) 15 l/h (0,0088 cfm)
Operating temperature range 1,5 - 65 °C (35-149 °F)
Inlet connection R 1/2’’
Outlet connection R 1/8’’
Power interface 3 × 0,75 mm2
Protection class IP65
Mass [kg] 0,9
Dimensions A × B × C [mm] 120 × 82 × 125
Peak compressor
performance
[m3/min]
11,6
9,3
5,8
Peak dryer performance
[m3/min]
23,2
18,6
11,6
Peak fi lter performance
[m3/min]
116
93
58
Compressor motor power [kW] 1 to 30
Please take the relevant climate zone into account when dimensioning yours specifi c EMD 12 drain series application:
Northern Europe, Canada, Northern USA, Central Asia
Central and Southern Europe, Central America
South East Asian coastal regions, Oceania, Amazon and Congo regions
The new generation of electronic condensate drains - EMD 12 series, is used for the automatic discharge of accumulated condensate from compressed air systems. The basic principle is contactless measurement of the acumulated condensate which is then discharged without the loss of valuable compressed air.
Condensate fl ow constantly fl ushes debris out of the valve. Thats why uninterrupted operating is guaranteed.
Incorrect plunger position is fi rst sign of debris blocking the valve. By detecting incorrect position, blocked plunger release procedure is started. This procedure assures safety and reliable plunger operating. No staff intervention is needed. This procedure starts automatilally.
www.omega-air.si 25
timer controlled condensate drains
Model Voltage Frequency El. powerProtection
class
Cable
dimension
Dimensions
A B C
TD16M 115 VAC 115 V +/- 10% 50-60 Hz 18 W IP54 3 x 0,75 mm2 3 7/16 inch 3 1/2 inch 4 7/8 inch
TD16M 230 VAC 230 V +/- 10% 50-60 Hz 18 W IP54 3 x 0,75 mm2
TD16 M is condensate drain which allows the user to discharge condensate for a controlled time and duration.
Its purpose is draining acumulated condensate from fi lters or pressure vessels. TD16 M is adaptable according to diff erent applications, discharge frequency and opening time.
Benefi ts
- easy opening time settings- easy opening frequency settings- no moving parts- reliable operating without clogging and unsensible to outside conditions- test button- warning LED light for condense disposal phase
Technical data - min/max operating temperature: 1,5 to 65 °C (35 to 149 °F)- min/max operating pressure: 0-16 bar / 0-232 psi- Input connection: R 1/2”- output connection: R 1/8”- output pipe diameter: 6-8 mm- capacity at 10 bar (145 psi): 0,2 - 114 l/h - mass: 0,35 kg
0 ÷ 16 bar
1,5 ÷ 65 °C
0,2 ÷ 114 l/h
condensate treatment
26
timer controlled condensate drains
Model Voltage Frequency El. powerProtection
class
Cable
dimension
Dimensions
A B C
TD16S 115 VAC 115 V +/- 10% 50-60 Hz 18 W IP54 3 x 0,75 mm2 3 7/16 inch 3 1/2 inch 4 7/8 inch
TD16S 230 VAC 230 V +/- 10% 50-60 Hz 18 W IP54 3 x 0,75 mm2
TD16 S is condensate drain which allows the user to discharge condensate for a controlled time and duration.
Its purpose is draining acumulated condensate from fi lters or pressure vessels. TD16 S is adaptable according to diff erent applications, discharge frequency and opening time.
Benefi ts
- easy opening time settings- easy opening frequency settings- no moving parts- reliable operating without clogging and unsensible to outside conditions- test button- warning LED light for condense disposal phase
Technical data - min/max operating temperature: 1,5 to 65 °C (35 to 149 °F)- min/max operating pressure: 0-16 bar / 0-232 psi- Input connection: R 1/2”- output connection: R 1/8”- output pipe diameter: 6-8 mm- capacity at 10 bar (145 psi): 0,2 - 114 l/h - mass: 0,35 kg
C
A
B
0 ÷ 16 bar
1,5 ÷ 65 °C
0,2 ÷ 114 l/h
condensate treatment
www.omega-air.si 27
condensate treatment
automatic condensate drains - 20 bar
The AOK 20 is used when larger amounts of condensate (up to 300 l/h) must be automatically discharged from fi lters, pressure vessels and cyclone separators. It ensures reliable operation up to 20 barg (290 psig). When the condensate exceeds the discharge level, the fl oat rises, opens the discharge aperture and discharges condensate from the system. We reccomend the installation of the nipple, which improves the performance of the AOK 20B.
Technical data- material: aluminium alloy- operating temperature range: 1,5 to 65 °C (35 to 149 °F)- operating pressure range: 0 - 20 bar (0 - 290 psi)- connection: R 1/2’’- oil resistant o-ring
132130
107
1/2’’
1/2’’
0 ÷ 20 bar
1,5 ÷ 65 °C
up to 300 l/h
28
MCD - Manual Condensate Drain
Manual Condensate Drains MCD are used for discharging condensate from fi lters and other vessels with 1/2’’ drain connections. In order to prevent condensate from becoming re-entrained in the airstream we reccomend controlling the condensate level in fi lter bowl, which requires an automatic drain trap. For improved, automatic discharge we recommend the use of other Omega Air products.
Technical data- material: brass- operating temperature range: 1,5 to 65 °C (35 to 149 °F)- operating pressure range: 0-16 bar (0-232 psi)- connection: R 1/2’’- oil resistant o-ring
AOK 16B - Automatic Condensate Drain
AOK 16B is primarly used in fi lters. Its task is the automatic discharge of condensate and oil. When the accumulated condensate exceeds to discharge level, the fl oat rises, opens the outlet aperture, and discharges condensate from the system.A manual emergency drain allows the operator to manually drain the fi lter, and confi rm the automatic operation.
Technical data- material: durable plastic, brass- operating temperature range: 1,5 to 65 °C (35 to 149 °F)- operating pressure range: 0-16 bar (0-232 psi)- connection: R 1/2’’- oil resistant o-ring
condensate treatment
mechanical condensate drains
29
Separator model
WOS-M1 WOS-M2 WOS-M4
Max. capacity of compressed air [m3/h] / [m3/min] 60 / 1 120 / 2 180 / 3
Max. oil adsorbtion [Ltr]
patented
1,5 ÷ 45 °C
1, 2, 4 m3/min
condensate treatment
water-oil separator
Local environmental laws and regulations state that condensate drained from compressed air systems cannot be returned to the sewage system due to the content of compressor lubricating oil.
WOS-M is an oil separator unit with disposal fi lter cartridge
Multi-stage separation process using oleophilic fi lters and activated carbon, ensures exceptional performance and trouble free operation.
WOS-M series covers compressor capacities up to 4 m3/min.
Benefi ts
• no complex sizing required,• fl oor or wall installation,• works with any type od condensate drain,• can handle and separate any type of oil, • oil residue value is less than 20 ppm, • easy to maintain,• disposable fi lter cartridge,• quick and clean fi lter cartridge changing, • quick cooupling connection,• no condensate settling tank is required (therefore
there is no bacteria build-up),• small compact design,
DEPRESSURIZE CHAMBER WITH AIR FILTER
INLET» condensate (oil, water)» air
AIR OUTLET
OIL FILTER CARTRIDGE(polypropilene fibres)
ACTIVE CARBON FILTER CARTRIDGE- final oil elimination
CLEAN WATER OUTLETresidual oil content < 20 ppm
Disposable filter cartridge
30
Local environmental laws and regulations state that condensate drained from compressed air systems cannot be returned to the sewage system due to the content of compressor lubricating oil.
WOS is one of the most eff ective and economical water oil separators. Multi-stage separation process using oleophilic fi lters and activated carbon, ensures exceptional performance and trouble free operation.
WOS series covers all compressor capacities up to 35 m3/min.
Benefi ts
• no complex sizing required,• simple to install,• works with any type od condensate drain,• can handle and separate any type of oil, • oil residue value is less than 10 ppm, • easy to maintain,• no condensate settling tank is required (therefore there is no bacteria build-up),• small compact design,• test valve and test set included for sampling purposes.
water - oil separators
1,5 ÷ 45 °C
4, 8, 20, 35 m3/min
condensate treatment
Water quality test
Water quality test should be performed at least once per month, to control the contamination level of disposed condensate.
If oil concentration is reached, oil fi lter cartridges must be changed.
www.omega-air.si 31
C
A B
Separator model
WOS-4 WOS-8 WOS-20 WOS-35
Max. capacity of compressed air [m3/h] / [m3/min] 240 / 4 480 / 8 1200 / 20 2100 / 35
Max. oil adsorbtion [Ltr] 3 10 15 25
Inlet connections [pcs] 1 2 2 4
Outlet connections [pcs] 1 1 1 1
Dimensions A×B×C [mm] 407×185×404 650×250×650 800×350×1000 1100×330×1150
DEPRESSURIZE CHAMBER WITH AIR FILTER
INLET» condensate (oil, water)» air AIR OUTLET
» condensate (oil, water)
OIL FILTER CARTRIDGE(polypropilene fibres)
ACTIVE CARBON FILTER CARTRIDGE- final oil elimination
CLEAN WATEROUTLETresidual oil content <10ppm
1st stage chamber
2nd stage chamber
32
B
CA
D
CORRECTION FACTORS
Operating pressure [bar] 3 5 7 10 13 16 20 30 40 50
Operating pressure [psi] 44 72 100 145 189 232 290 435 580 725
Correction factor 0,50 0,75 1 1,38 1,75 2,13 2,63 3,88 5,13 6,38
Filter
model
Connection
[D]
Flow rate
at 7 bar(g) Dimensions [mm] Dimensions [inch] Mass Filter
cartridgeinch Nm3/h SCFM A B C A B C kg lb
HF 007 1/2 71 418 250 110 30 9 7/8 4 5/16 1 3/16 2,1 4,63 HF 6060
HF 010 3/4 112 659 250 110 30 9 7/8 4 5/16 1 3/16 2,1 4,63 HF 7060
HF 018 1 204 765 250 110 30 9 7/8 4 5/16 1 3/16 2,1 4,63 HF 12060
HF 047 1 1/2 282 1059 535 160 45 21 1/16 6 5/16 1 3/4 9,5 20,9 HF 22090
HF 070 1 1/2 400 1500 535 160 45 21 1/16 6 5/16 1 3/4 9,5 20,9 HF 32090
HF 094 2 494 1853 715 160 45 21 1/8 6 5/16 1 3/4 12,2 26,9 HF 50090
HF 150 2 799 3000 715 160 45 21 1/8 6 5/16 1 3/4 12,2 26,9 HF 51090
High Pressure Filters HF are used for industrial applications with pressure up to 50 bar (725 psi). Strong cast aluminium construction assures safety operating at high pressures.
HF series is produced in accordance with Pressure Equipment Directive PED 97/23 CE.
- max. operating pressure: 50 bar (725 psi)- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
All fi lter housings are coated with powder paint colour to prevent corrosion.
1/2’’
cast aluminium high pressure filters - 50 bar
50 bar
1,5 ÷ 65 °C
450 ÷ 5.100 Nm3/h
industrial applications
www.omega-air.si 33
Filter’s
housing
Flow rate at 7 bar(g), 20°C
Max. operat-
ing pressure
[bar/psi]
Max.
operating
temp. [°C/°F]
B
sintered
15 μm
P
prefi lter
3 μm
R
prefi lter
1 μm
M
microfi lter
0,1 μm
S
microfi lter
0,01 μm
A
active
carbonNm3/h SCFM
HF 007 71 418 50/725 65/149** HF 6060 B HF 6060 P HF 6060 R HF 6060 M HF 6060 S HF 6060 A
HF 010 112 659 50/725 65/149** HF 7060 B HF 7060 P HF 7060 R HF 7060 M HF 7060 S HF 7060 A
HF 018 204 765 50/725 65/149** HF 12060 B HF 12060 P HF 12060 R HF 12060 M HF 12060 S HF 12060 A
HF 047 282 1059 50/725 65/149** HF 22090 B HF 22090 P HF 22090 R HF 22090 M HF 22090 S HF 22090 A
HF 070 400 1500 50/725 65/149** HF 32090 B HF 32090 P HF 32090 R HF 32090 M HF 32090 S HF 32090 A
HF 094 494 1853 50/725 65/149** HF 50090 B HF 50090 P HF 50090 R HF 50090 M HF 50090 S HF 50090 A
HF 150 799 3000 50/725 65/149** HF 51090 B HF 51090 P HF 51090 R HF 51090 M HF 51090 S HF 51090 A
B P R M S A
solid particle size purifi cation: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
quality class - solids (ISO 8573-1) 4 3 2 1 1 -
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005 / 0,005
quality class - oils (ISO 8573-1) - - - 2 1 1
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change fi lter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
fi lter material sintered brass acrile fi bres, celulose borosilicate micro fi bres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon fi lters must not operate in oil saturated conditions.
** 45 °C / 139°F for active carbon cartridges!
HF filter cartridgesSix fi ltration grades enables elimination of impurities from compressed air in a temperature range 1,5 to 65 °C (35 to 149°F).
34
B
A
D
CORRECTION FACTORS
Operating pressure [bar] 3 5 7 10 13 16 20 30 40 50 60 64
Operating pressure [psi] 44 72 100 145 189 232 290 435 580 725 870 928
Correction factor 0,63 0,88 1 1,38 1,75 2,13 2,63 3,88 5,13 6,38 7,63 8,13
Filter
housing
model
Connections
[D]
Flow rate at 7 bar(g), 20°C Dimensions [mm] Mass
Cartridge
inch Nm3/h A B C kg
AHP 005 3/8’’ 30 167 104 90 2,25 HP 06050
AHP 007 1/2’’ 60 167 104 90 2,25 HP 07050
AHP 010 3/4’’ 120 232 104 90 2,84 HP 14050
AHP 018 1’’ 180 258 150 120 6,45 HP 12075
AHP 030 1 1/4’’ 270 358 150 120 7,8 HP 22075
AHP 047 1 1/2’’ 360 458 150 120 9,17 HP 32075
AHP 094 2’’ 720 665 170 150 18,9 HP 51090
Aluminum high pressure fi lters AHP are used for industrial high pressure applications up to 64 bar (928 psi).
Strong construction is made of round aluminum bars. This assures high mechanical properties and higher operating safety.On customer request fi lters can be shiny polished or anodized.
AHP fi lters are made in 6 diff erent fi ltration stages which enables operating in a temperature range from 1,5 to 65 °C (35 to 149 °F).
- max. operating pressure: 64 bar (928 psi)- operating temperature range: 1,5 to 65 °C (35 to 149 °F)
C
1/2’’
aluminium high pressure filters - 64 bar
64 bar
1,5 ÷ 65 °C
30 ÷ 720 Nm3/h
industrial applications
www.omega-air.si 35
Filter’s
housing
Flow rate at 7 bar(g), 20°C
Max. operat-
ing pressure
[bar/psi]
Max.
operating
temp. [°C/°F]
B
sintered
15 μm
P
prefi lter
3 μm
R
prefi lter
1 μm
M
microfi lter
0,1 μm
S
microfi lter
0,01 μm
A
active
carbonNm3/h SCFM
AHP 005 30 17,6 64/928 65/149** AHP 06050 B AHP 06050 P AHP 06050 R AHP 06050 M AHP 06050 S AHP 06050 A
AHP 007 60 35,3 64/928 65/149** AHP 07050 B AHP 07050 P AHP 07050 R AHP 07050 M AHP 07050 S AHP 07050 A
AHP 010 120 70,6 64/928 65/149** AHP 14050 B AHP 14050 P AHP 14050 R AHP 14050 M AHP 14050 S AHP 14050 A
AHP 018 180 106 64/928 65/149** AHP 12075 B AHP 12075 P AHP 12075 R AHP 12075 M AHP 12075 S AHP 12075 A
AHP 030 270 159 64/928 65/149** AHP 22075 B AHP 22075 P AHP 22075 R AHP 22075 M AHP 22075 S AHP 22075 A
AHP 047 360 212 64/928 65/149** AHP 32075 B AHP 32075 P AHP 32075 R AHP 32075 M AHP 32075 S AHP 32075 A
AHP 094 720 423 64/928 65/149** AHP 51090 B AHP 51090 P AHP 51090 R AHP 51090 M AHP 51090 S AHP 51090 A
B P R M S A
solid particle size purifi cation: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
quality class - solids (ISO 8573-1) 4 3 2 1 1 -
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005 / 0,005
quality class - oils (ISO 8573-1) - - - 2 1 1
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change fi lter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
fi lter material sintered brass acrile fi bres, celulose borosilicate micro fi bres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
AHP filter cartridges
Filter cartridges for high pressure applications are designed for pressure range up to 64 bar.
Because of these operating parametres, support mesh is made of durable expanded stainless steel mesh, which protects cartridge construction against destruction.
End caps are made of aluminium, thread on upper end cap additionally ensures safety installation into fi lter head.
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon fi lters must not operate in oil saturated conditions.
** 45 °C / 139°F for active carbon cartridges!
36
B
A
D
C
CORRECTION FACTORS
Operating pressure [bar] 7 25 40 64 100 250 400
Operating pressure [psi] 100 362 580 928 1450 3625 5800
Correction factor 1 3 5 8 12 12 12
Model
fi ltra
Connections
[D]
Flow rate at 7 bar(g), 20°C Dimensions [mm] Mass
Cartridge size
inch Nm3/h A B C kg
CHP 003 1/4’’ 40 165 83,5 70 4,6 0305
CHP 005 3/8’’ 70 165 83,5 70 4,6 0310
CHP 007 1/2’’ 130 210 105 85 8,7 0420
CHP 010 3/4’’ 195 210 105 85 9,3 0520
CHP 018 1’’ 275 253 119 100 11,6 0525
CHP 030 1 1/4’’ 380 303 119 100 16 0725
CHP 047 1 1/2’’ 495 329 146 130 26,5 0730
CHP 094 2’’ 715 415 182 150 49 1030
Carbon steel high pressure fi lters CHP are used for industrial high pressure applications up to 400 bar (5800 psi).
Extremely strong construction is made of round carbon steel bars. This assures high mechanical properties and higher operating safety.
CHP fi lters are made in 6 diff erent fi ltration stages which enables operating in a temperature range from 1,5 to 65 °C (35 to 149 °F).
- max. operating pressure: 100, 250, 400 bar - operating temperature range: 1,5 to 65 °C (35 to 149 °F)
- material certifi cate: EN 10204 – 3,18- material: C22,8 – chem. Nickel (25 μm)
1/2’’
carbon steel high pressure filters - 100-250-400 bar
100, 250, 400 bar
1,5 ÷ 65 °C
40 ÷ 715 Nm3/h
industrial applications
www.omega-air.si 37
Filter’s
housing
Flow rate at 7 bar(g), 20°C
Max. operat-
ing pressure
[bar]
Max.
operating
temp. [°C/°F]
B
sintered
15 μm
P
prefi lter
3 μm
R
prefi lter
1 μm
M
microfi lter
0,1 μm
S
microfi lter
0,01 μm
A
active
carbonNm3/h SCFM
CHP 003 40 23,5 100/250/400 65/149** CHP 0305 B CHP 0305 P CHP 0305 R CHP 0305 M CHP 0305 S CHP 0305 A
CHP 005 70 41,2 100/250/400 65/149** CHP 0310 B CHP 0310 P CHP 0310 R CHP 0310 M CHP 0310 S CHP 0310 A
CHP 007 130 76,5 100/250/400 65/149** CHP 0420 B CHP 0420 P CHP 0420 R CHP 0420 M CHP 0420 S CHP 0420 A
CHP 010 195 115 100/250/400 65/149** CHP 0520 B CHP 0520 P CHP 0520 R CHP 0520 M CHP 0520 S CHP 0520 A
CHP 018 275 162 100/250/400 65/149** CHP 0525 B CHP 0525 P CHP 0525 R CHP 0525 M CHP 0525 S CHP 0525 A
CHP 030 380 223 100/250/400 65/149** CHP 0725 B CHP 0725 P CHP 0725 R CHP 0725 M CHP 0725 S CHP 0725 A
CHP 047 495 291 100/250/400 65/149** CHP 0730 B CHP 0730 P CHP 0730 R CHP 0730 M CHP 0730 S CHP 0730 A
CHP 094 715 421 100/250/400 65/149** CHP 1030 B CHP 1030 P CHP 1030 R CHP 1030 M CHP 1030 S CHP 1030 A
B P R M S A
solid particle size purifi cation: down to 15 microns 3 microns 1 micron 0,1 micron 0,01 micron -
quality class - solids (ISO 8573-1) 4 3 2 1 1 -
residual oil content [mg/m3 / ppm] - - - 0,1 / 0,08 0,01 / 0,01 0,005 / 0,005
quality class - oils (ISO 8573-1) - - - 2 1 1
pressure drop - new element [mbar / psi] 30 / 0,43 40 / 0,58 <50 / 0,72 <80 / 1,16 120 / 1,74 <90 / 1,3
change fi lter cartridge at pressure drop [mbar / psi] 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 600 / 8,7 *every 6 months
fi lter material sintered brass acrile fi bres, celulose borosilicate micro fi bres active carbon
pleated version - + + + + -
wrapped version - + + + + +
sintered version + - - - - -
CHP filter cartridges
Filter cartridges for high pressure applications are designed for pressure range up to 400 bar.
Because of these operating parametres, support mesh is made of durable expanded stainless steel mesh, which protects cartridge construction against destruction.
End caps are made of aluminium, thread on upper end cap additionally ensures safety installation into fi lter head.
* Filter elements ’’A’’ must be changed periodically to suit application but at least every 6 months. Activated carbon fi lters must not operate in oil saturated conditions.
** 45 °C / 139°F for active carbon cartridges!
38
Process Filters PF are designed for applications in process industry, where the risk for corrosion of compressed air system components is very high.
PF fi lters are therefore made of high quality stainless steel for pharmaceutical industry (quality 1.4301; on request 1.4404). Housing is polished down to grade Ra1.6.
Filter housings can include BSP or NPT pipe connections. Every product is tested several times to assure reliability and quality of our products.
- max. operating pressure: 10 (12,16) bar- operating temperature range: up to 150 °C
Filter model
Connection
input & output
D [inch]
Flow rate at 7 bar(g),
20°C[Nm3/h]
Dimensions [mm] Mass Operating
pressure
[bar]
Filter’s
cartridge sizeA B C E [kg]
PF 005 1/4’’ 75 200 116 76,1 1/4’’ 1,7 16 1x0310
PF 007 3/8’’ 105 231 120 76,1 1/4’’ 1,9 16 1x0410
PF 010 1/2’’ 150 231 125 76,1 1/4’’ 1,9 16 1x0420
PF 018 3/4’’ 225 253 125 76,1 1/4’’ 2,0 16 1x0520
PF 030 1’’ 315 272 136 88,9 1/4’’ 2,6 16 1x0525
PF 047 1 1/4’’ 420 334 155 88,9 1/4’’ 3,0 16 1x0725
PF 070 1 1/2’’ 600 386 180 114,3 1/4’’ 4,3 16 1x0730
PF 094 2’’ 900 453 180 114,3 1/4’’ 4,8 16 1x1030
PF 150 2’’ 1260 580 180 114,3 1/4’’ 5,3 16 1x1530
PF 175 2 1/2’’ 1680 740 224 139,7 1/4’’ 9,0 16 1x2030
PF 200 3’’ 2400 1008 224 139,7 1/4’’ 10,8 12 1x3030
PF 240 3’’ 3600 1040 255 168,3 1/4’’ 16,2 12 1x3050
PF 450 DN100 5040 986 410 219,1 1’’ 45 10 3x2030
PF 600 DN100 6720 1240 410 219,1 1’’ 46 10 3x3030
PF 900 DN150 9600 1300 480 273,0 1’’ 70 10 4x3030
PF 1200 DN150 13440 1350 540 323,9 1’’ 80 10 6x3030
PF 1800 DN200 17280 1500 660 406,4 1’’ 135 10 8x3030
PF 2000 DN200 21120 1500 660 406,4 1’’ 135 10 10x3030
A
B
øC
D
E
E
stainless steel process filters
10 (12, 16) bar
up to 150 °C
75 ÷ 21.120 Nm3/h
process applications
www.omega-air.si 39
PI PB PPM Flow rate at 7 bar(g), 20°C
[Nm3/h]
Max. oper.
pressure
[bar]
Filter’s housing25 μm 15 μm 0,01 μm
1x0310-PI 1x0310-PB 1x0310-PPM 75 16 PF 005
1x0410-PI 1x0410-PB 1x0410-PPM 105 16 PF 007
1x0420-PI 1x0420-PB 1x0420-PPM 150 16 PF 010
1x0520-PI 1x0520-PB 1x0520-PPM 225 16 PF 018
1x0525-PI 1x0525-PB 1x0525-PPM 315 16 PF 030
1x0725-PI 1x0725-PB 1x0725-PPM 420 16 PF 047
1x0730-PI 1x0730-PB 1x0730-PPM 600 16 PF 070
1x1030-PI 1x1030-PB 1x1030-PPM 900 16 PF 094
1x1530-PI 1x1530-PB 1x1530-PPM 1260 16 PF 150
1x2030-PI 1x2030-PB 1x2030-PPM 1680 16 PF 175
1x3030-PI 1x3030-PB 1x3030-PPM 2400 12 PF 200
1x3050-PI 1x3050-PB 1x3050-PPM 3600 12 PF 240
3x2030-PI 3x2030-PB 3x2030-PPM 5040 10 PF 450
3x3030-PI 3x3030-PB 3x3030-PPM 6720 10 PF 600
4x3030-PI 4x3030-PB 4x3030-PPM 9600 10 PF 900
6x3030-PI 6x3030-PB 6x3030-PPM 13440 10 PF 1200
8x3030-PI 8x3030-PB 8x3030-PPM 17280 10 PF 1800
10x3030-PI 10x3030-PB 10x3030-PPM 21120 10 PF 2000
PI PB PPM
sintered INOX sintered bronze borosilicate paper fi lter material
25 μm 15 μm 0,01 μm solid particle size purifi cation: down to
quality class - solids (ISO 8573-1)
quality class - oils (ISO 8573-1)
1,5-150°C 1,5-150°C 1,5-120°C(65°C*) operating temperature range
30 40 100 pressure drop - new element [mbar / psi]
600 600 600 change fi lter cartridge at pressure drop [mbar / psi]
* For silicone free binding materials!
PF filter cartridges
Process sintered stainless steel fi lter cartridges are made of sintered stainless steel, which unsures safety operating without risk for corrosion.
There are two additional fi lter grades, made of sintered bronze (15 μm) and borosilicate micro paper (0,01 μm) .
40
High pressure process fi lters HPF are designed for high pressure applications in process industry, where the risk for corrosion of compressed air system components is very high.
HPF fi lters are therefore made of high quality stainless steel for pharmaceutical industry (quality 1.4301; on request 1.4404). Housing is polished down to grade Ra1.6.
Filter housings can include BSP or NPT pipe connections.
Every product is tested several times to assure reliability and quality of our products.
- max. operating pressure: 50 bar- operating temperature range: up to 150 °C
Filter modelConnection
D [inch]
Flow rate at 7 bar(g),
20°C[Nm3/h]
Dimensions [mm]Mass
[kg]
Operating
pressure
[bar]
Filter’s
cartridge sizeA B C
HPF 010/50 1/2’’ 450 243 108 76,1 2,5 50 1x0420
HPF 018/50 3/4’’ 715 266 125 76,1 2,6 50 1x0520
HPF 030/50 1’’ 1300 293 125 88,9 3,4 50 1x0525
HPF 047/50 1 1/4’’ 1800 344 140 88,9 3,9 50 1x0725
HPF 070/50 1 1/2’’ 2550 386 170 114,3 5,6 50 1x0730
HPF 094/50 2’’ 3150 460 170 114,3 6,2 50 1x1030
HPF 150/50 2’’ 5100 587 170 114,3 6,9 50 1x1530
HPF 200/50 3’’ 7200 987 216 139,7 14,1 50 1x3030
A
B
øC
1/2’’
D
1/2’’
high pressure process filters - 50 bar
50 bar
up to 150 °C
450 ÷ 7.200 Nm3/h
process applications
www.omega-air.si 41
HPI HPM HPA HPS Flow rate at 7 bar(g), 20°C
[Nm3/h]
Max. oper.
pressure
[bar]
Filter’s housing25 μm 0.01 μm active carbon sterile
1x0420-HPI 1x0420-HPM 1x0420-HPA 1x0420-HPS 450 50 HPF 010/50
1x0520-HPI 1x0520-HPM 1x0520-HPA 1x0520-HPS 715 50 HPF 018/50
1x0525-HPI 1x0525-HPM 1x0525-HPA 1x0525-HPS 1300 50 HPF 030/50
1x0725-HPI 1x0725-HPM 1x0725-HPA 1x0725-HPS 1800 50 HPF 047/50
1x0730-HPI 1x0730-HPM 1x0730-HPA 1x0730-HPS 2550 50 HPF 070/50
1x1030-HPI 1x1030-HPM 1x1030-HPA 1x1030-HPS 3150 50 HPF 094/50
1x1530-HPI 1x1530-HPM 1x1530-HPA 1x1530-HPS 5100 50 HPF 150/50
1x3030-HPI 1x3030-HPM 1x3030-HPA 1x3030-HPS 7200 50 HPF 200/50
HPI HPM HPA HPS
sintered INOX borosilicate paper active carbon borosilicate microfi bres fi lter material
25 μm 0.01 μm - 0.01 μm solid particle size purifi cation: down to
quality class - solids (ISO 8573-1)
quality class - oils (ISO 8573-1)
up to 150°C up to 65°C up to 65°C up to 150°C operating temperature range
200°C short duration (max. 15 min) temperature limit
30 40 100 pressure drop - new element [mbar / psi]
600 600 600 change fi lter cartridge at pressure drop [mbar / psi]
HPF filter cartridges
High pressure process fi lter cartridges can be made in 4 diff erent versions:- sintered inox,- microfi lter paper,- active carbon,- sterile.
42
Stainless steel Sterile Filters SF are designed for removing of impurities from compressed air applications in pharmaceutical, chemical and food industry, in biotechnology, breweries, dairies, hospitals and aseptic packaging.
SF fi lters are therefore made of high quality stainless steel (quality 1.4301; on request 1.4404). Housing is polished down to grade Ra0,8.
Filter media are borosilicate microfi bres, which can eliminate up to 99,99% of impurities sizes down to 0,01μm.
- max. operating pressure: 10 (16) bar- operating temperature range: -20 – 150°C- 15 min temp. limit during sterilisation: 200°C
Filter modelConnection
DN / ø
Flow rate at 7 bar(g), 20°C
[Nm3/h]
Dimensions [mm] Mass Operating
pressure
[bar]
Filter cartridge
A B C D E [kg]
SF 0006 DN10 / ø17,2 75 218 125 76,1 69 1/8’’ 1,6 16 1x0310-VSF
SF 0009 DN10 / ø17,2 105 246 125 76,1 69 1/8’’ 1,7 16 1x0410-VSF
SF 0012 DN15 / ø21,3 150 251 120 76,1 69 1/8’’ 1,7 16 1x0420-VSF
SF 0018 DN15 / ø21,3 225 275 120 76,1 69 1/8’’ 1,8 16 1x0520-VSF
SF 0032 DN25 / ø33,7 315 303 169 114,3 86 1/4’’ 3,1 16 1x0530-VSF
SF 0048 DN32 / ø42,4 600 363 169 114,3 86 1/4’’ 3,4 16 1x0730-VSF
SF 0072 DN40 / ø48,3 900 446 169 114,3 86 1/4’’ 3,6 16 1x1030-VSF
SF 0108 DN50 / ø60,3 1.260 585 183 114,3 96 1/4’’ 4,9 16 1x1530-VSF
SF 0144 DN65 / ø76,1 1.680 763 195 139,7 120 1/4’’ 8,4 16 1x2030-VSF
SF 0192 DN80 / ø88,9 2.400 1015 195 139,7 120 1/4’’ 10,2 16 1x3030-VSF
SF 0432 DN100 5.040 1012 410 219,1 183 1/2’’ 44 10 3x2030-VSF
SF 0576 DN100 6.720 1266 410 219,1 183 1/2’’ 45 10 3x3030-VSF
SF 0768 DN150 9.600 1326 480 273 225 1/2’’ 70 10 4x3030-VSF
SF 1152 DN150 13.440 1418 540 323,9 256 1’’ 80 10 6x3030-VSF
SF 1536 DN200 17.200 1568 660 406,4 306 1’’ 135 10 8x3030-VSF
SF 1920 DN200 21.120 1568 660 406,4 306 1’’ 135 10 10x3030-VSF
A
B
øC
D
øC
B
AD
E
E
stainless steel sterile filters - 16 bar
10 (16) bar
-20 ÷ 150 °C
75 ÷ 21.120 Nm3/h
sterile applications
E
E
www.omega-air.si 43
SF filter cartridges Filter media are high quality borosilicate microfi bres, which eliminates up to 99,99% of Impurities sized down to 0,01 μm.
Sterile fi lter cartridge
Flow rate at 7 bar(g), 20°C
[Nm3/h]
Max. oper.
pressure
[bar]
Max. oper.
temperature
[°C/°F]
Filter’s housing
1 x 0310-VSF 75 16 150/302 SF 0006
1x0410-VSF 105 16 150/302 SF 0009
1x0420-VSF 150 16 150/302 SF 0012
1 x 0520-VSF 225 16 150/302 SF 0018
1 x 0530-VSF 315 16 150/302 SF 0032
1 x 0730-VSF 600 16 150/302 SF 0048
1 x 1030-VSF 900 16 150/302 SF 0072
1 x 1530-VSF 1.260 16 150/302 SF 0108
1 x 2030-VSF 1.680 16 150/302 SF 0144
1 x 3030-VSF 2.400 16 150/302 SF 0192
3 x 2030-VSF 5.040 10 150/302 SF 0432
3 x 3030-VSF 6.720 10 150/302 SF 0576
4 x 3030-VSF 9.600 10 150/302 SF 0768
6 x 3030-VSF 13.440 10 150/302 SF 1152
8 x 3030-VSF 17.200 10 150/302 SF 1536
10 x 3030-VSF 21.120 10 150/302 SF 1920
VSF
0,01 μm solid particle size purifi cation: down to
1 quality class - solids (ISO 8573-1)
- quality class - oils (ISO 8573-1)
30 pressure drop - new element [mbar / psi]
600 change fi lter cartridge at pressure drop [mbar / psi]
borosilicate micro fi bres fi lter material
44
A
B
øC
D
SPF fi lters are designed for applications in process industry, where the risk for corrosion of compressed air system components is very high.
SPF fi lters are therefore made of high quality stainless steel for pharmaceutical industry (quality 1.4301; on request 1.4404). Housing is polished down to grade Ra 0,8.
Filter housings can include BSP or NPT pipe connections.
Every product is tested several times to assure reliability and quality of our products.
- max. operating pressure: 10 (12, 16) bar- operating temperature range: -20 – 150 °C- short duration (15 min) temp. limit: up to 200 °C
Filter modelConnection
D [inch]
Flow rate at 7 bar(g),
20°C[Nm3/h]
Dimensions [mm]Mass
[kg]
Operating
pressure
[bar]
Filter’s
cartridge sizeA B C E
SPF 005 1/4’’ 75 223 116 76,1 1/8’’ 1,7 16 1x0310
SPF 007 3/8’’ 105 254 120 76,1 1/8’’ 1,9 16 1x0410
SPF 010 1/2’’ 150 254 125 76,1 1/8’’ 1,9 16 1x0420
SPF 018 3/4’’ 225 276 125 76,1 1/8’’ 2,0 16 1x0520
SPF 030 1’’ 315 295 136 88,9 1/8’’ 2,6 16 1x0525
SPF 047 1 1/4’’ 420 357 155 88,9 1/8’’ 3,0 16 1x0725
SPF 070 1 1/2’’ 600 408 180 114,3 1/4’’ 4,3 16 1x0730
SPF 094 2’’ 900 476 180 114,3 1/4’’ 4,8 16 1x1030
SPF 150 2’’ 1260 602 180 114,3 1/4’’ 5,3 16 1x1530
SPF 175 2 1/2’’ 1680 762 224 139,7 1/4’’ 9,0 16 1x2030
SPF 200 3’’ 2400 1030 224 139,7 1/4’’ 10,8 12 1x3030
SPF 240 3’’ 3600 1062 255 168,3 1/4’’ 16,2 12 1x3050 E
E
stainless steel sterile filters - 16 bar
10 (12, 16) bar
-20 ÷ 150 °C
75 ÷ 3.600 Nm3/h
sterile & industrial applications
www.omega-air.si 45
SPF filter cartridges High pressure process fi lter cartridges can be made in 4 diff erent versions:- sintered inox,- microfi lter paper,- active carbon,- sterile.
Sterile fi lter cartridge Industrial fi lter cartridge Flow rate
at 7 bar(g), 20°C[Nm3/h]
Max. oper. pressure
[bar]
Max. oper. temperature
[°C]Filter’s housing
SPFs SPFn SPFi SPFP
0310-SPFs 0310-SPFn 0310-SPFi 0310-SPFP 75 16 150 SPF 005
0410-SPFs 0410-SPFn 0410-SPFi 0410-SPFP 105 16 150 SPF 007
0420-SPFs 0420-SPFn 0420-SPFi 0420-SPFP 150 16 150 SPF 010
0520-SPFs 0520-SPFn 0520-SPFi 0520-SPFP 225 16 150 SPF 018
0525-SPFs 0525-SPFn 0525-SPFi 0525-SPFP 315 16 150 SPF 030
0725-SPFs 0725-SPFn 0725-SPFi 0725-SPFP 420 16 150 SPF 047
0730-SPFs 0730-SPFn 0730-SPFi 0730-SPFP 600 16 150 SPF 070
1030-SPFs 1030-SPFn 1030-SPFi 1030-SPFP 900 16 150 SPF 094
1530-SPFs 1530-SPFn 1530-SPFi 1530-SPFP 1260 10 150 SPF 150
2030-SPFs 2030-SPFn 2030-SPFi 2030-SPFP 1680 10 150 SPF 175
3030-SPFs 3030-SPFn 3030-SPFi 3030-SPFP 2400 10 150 SPF 200
3050-SPFs 3050-SPFn 3050-SPFi 3050-SPFP 3600 10 150 SPF 240
SPFs SPFn SPFi SPFP
0,01 μm 20 μm 25 μm 0,01 μm solid particle size purifi cation: down to
quality class - solids (ISO 8573-1)
quality class - oils (ISO 8573-1)
30 30 30 120 pressure drop - new element [mbar / psi]
600 600 600 600 change fi lter cartridge at pressure drop [mbar / psi]
borosilicate microfi bres sintered INOX fi lter material
up to 150°C up to 150°C up to 150°C up to 120°C (65°C*) operating temperature range
up to 200°C up to 200°C up to 200°C short duration (max. 15 min) temperature limit
* For silicone free binding materials!
46
vacuum pump protection filters
vacuum applications
20 ÷ 20000 mbar (abs)
1,5 ÷ 65 °C
7,5 ÷ 345 Nm3/h
P-VAC fi lters have been specifi cally developed for protection of vacuum pumps. These fi lters are optimised for high-effi cient removal of solid particles and other contamination from the suction side of vacuum pumps preventing damage to the pump.
For P-VAC fi lter series two fi ltration stages are available.
Rough prefi lter “VACP”removes bulk liquid and large solid particles while high effi ciency microfi lter VACM removes very fi ne impurities which may damage the pump.
- operating pressure range: 20 - 2000 mbar (abs) (0,29 - 29 psi)- operating temp. range: 1,5 – 65 °C (35-149 °F)
APPLICATIONS • vacuum pumps
Filter modelConnection
[inch]
Free air capacity at
atmospheric pressure
Rearifi ed air capacity
at 500 mmHg vacuumDimensions [mm] Filter cartridge
Nm3/h scfm Nm3/h scfm A B D Type
pVAC 0056 3/8’’ 7,5 4,5 22,5 13,2 187 88 60 06050 VACP, VACM
pVAC 0076 1/2’’ 9,8 5,8 29,3 17,2 187 88 60 07050 VACP, VACM
pVAC 0106 3/4’’ 15,0 8,8 45,0 26,5 257 88 80 15050 VACP, VACM
pVAC 0186 1’’ 24,8 14,6 74,3 43,7 263 125 100 12075 VACP, VACM
pVAC 0306 1’’ 41,9 24,6 125 73,5 363 125 120 22075 VACP, VACM
pVAC 0476 1 1/2’’ 63,8 37,5 191 112 461 125 140 32075 VACP, VACM
pVAC 0706 1 1/2’’ 97,5 57,4 292 172 640 125 160 50075 VACP, VACM
pVAC 0946 2’’ 125 73,6 375 221 684 163 520 51090 VACP, VACM
pVAC 1506 2’’ 187 110 563 331 935 163 770 76090 VACP, VACM
pVAC 1756 2 1/2’’ 210 123 630 371 935 163 770 76090 VACP, VACM
pVAC 2006 3’’ 270 159 811 477 795 240 630 51140 VACP, VACM
pVAC 2406 3’’ 345 203 1036 609 1000 240 780 75140 VACP, VACM
Replace fi lter cartridge every 12 months or follow the instructions for specifi c fi lter element.
B
AD
www.omega-air.si 47
medical vacuum filters
vacuum applications
20 ÷ 2000 mbar (abs)
1.5 ÷ 65 °C
7.5 ÷ 787 Nm3/h
M-VAC fi lters are designed for medical vacuum applications. These fi lters are optimised for high-effi cient removal of bacterial and other contamination (solids and liquids) from the suction side of vacuum pumps preventing damage to the pump and the potential biological infection of the surrounding environment.
Removed liquids are collected in a transparent fl ask which can be removed for sterilisation.
The effi ciency of the installed fi lter elements exceeds the 0,005% penetrationspecifi ed in HTM 2022 for infections disease units, when tested in accordance with BS 3928.
- operating pressure range: 20 - 2000 mbar (abs)- operating temp. range: 1,5 – 65 °C (35-149 °F)
APPLICATIONS • operating theatres• maternity units• dental applications• pathology laboratories• pharmaceutic applications• mortuary and post-mortem rooms
Filter modelConnection
[inch]
Free air capacity at
atmospheric pressure
Rearifi ed air capacity
at 500 mmHg vacuumDimensions [mm] Filter cartridge
Nm3/h scfm Nm3/h scfm A B D Type Qty.
mVAC 0056 3/8’’ 7,5 4,5 22,5 13,2 187 88 60 06050 VAC 1
mVAC 0076 1/2’’ 9,8 5,8 29,3 17,2 187 88 60 07050 VAC 1
mVAC 0106 3/4’’ 15,0 8,8 45,0 26,5 257 88 80 15050 VAC 1
mVAC 0186 1’’ 24,8 14,6 74,3 43,7 263 125 100 12075 VAC 1
mVAC 0306 1’’ 41,9 24,6 125 73,5 363 125 120 22075 VAC 1
mVAC 0476 1 1/2’’ 63,8 37,5 191 112 461 125 140 32075 VAC 1
mVAC 0706 1 1/2’’ 97,5 57,4 292 172 640 125 160 50075 VAC 1
mVAC 0946 2’’ 125 73,6 375 221 684 163 520 51090 VAC 1
mVAC 1506 2’’ 187 110 563 331 935 163 770 76090 VAC 1
mVAC 1756 2 1/2’’ 210 123 630 371 935 163 770 76090 VAC 1
mVAC 2006 3’’ 270 159 811 477 795 240 630 51140 VAC 1
mVAC 2406 3’’ 345 203 1036 609 1000 240 780 75140 VAC 1
mVAC B240 DN80 275 162 825 485 1170 450
min 650 76090 VAC
1
mVAC B300 DN100 394 231 1182 695 1340 560 2
mVAC B450 DN125 587 345 1764 1064 1360 560 3
mVAC B600 DN150 787 463 2365 1392 1425 620 4
B
66A
120
D
B
AD
Replace fi lter cartridge every 12 months or follow the instructions for specifi c fi lter element. Used fi lter cartridges must be treated as bio-hazardous and must be removed according to valid local laws !
48
compressed natural gas filters
special applications
CNG fi lters are designed for high effi cient removal of solid particles and bulk liquids from compressed natural gas.
To meet the required compressed natural gas quality, appropriate fi lter element must be installed into fi lter housing.
- max. operating pressure: 20 bar (290 psi)- operating temperature range: 1,5 – 65 °C (35 - 149 °F)
APPLICATIONS:
• compressed natural gas
20 bar
1.5 ÷ 65 °C
72 ÷ 2.760 Nm3/h
Filter model Connection
Flow rate at 7 bar(g), 20°C Dimensions [mm] Mass
[kg]
Operating
pressure
[bar]
Filter
cartridge
sizeNm3/h scfm A B C D
CNG 20 3/8’’ 72 42 187 88 20 80 0,7 20 20 CNG
CNG 21 1/2’’ 96 56 256 88 20 80 0,8 20 21 CNG
CNG 30 1/2’’ 150 88 278 106 25 100 1,3 20 30 CNG
CNG 31 3/4’’ 216 127 278 106 25 100 1,3 20 31 CNG
CNG 40 1’’ 282 166 252 125 32 120 2,1 20 40 CNG
CNG 41 1’’ 360 212 352 125 32 140 2,4 20 41 CNG
CNG 42 1 1/4’’ 432 254 352 125 32 140 2,4 20 42 CNG
CNG 43 1 1/2’’ 510 300 450 125 32 160 3,2 20 43 CNG
CNG 44 1 1/2’’ 750 441 450 125 32 160 3,2 20 44 CNG
CNG 50 2’’ 888 522 605 160 43 180 5,1 20 50 CNG
CNG 51 2’’ 1176 692 605 160 43 180 5,1 20 51 CNG
CNG 52 2 1/2’’ 1440 847 685 160 43 200 6,3 20 52 CNG
CNG 60 3’’ 1968 1158 800 240 60 300 12,9 20 60 CNG
CNG 61 3’’ 2760 1624 800 240 60 300 12,9 20 61 CNG
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232 247 261 276 290
Correction factor 0,38 0,5 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13 2,25 2,38 2,50 2,63
B
80
C
AD
R 1/2’’
www.omega-air.si 49
CNGM CNGS Flow rate at 7 bar(g), 20°C Max. oper.
pressure
[bar/psi]
Filter’s housing0,1 μm 0,01 μm Nm3/h scfm
20 CNGM 20 CNGS 72 42 20/290 CNG 20
21 CNGM 21 CNGS 96 56 20/290 CNG 21
30 CNGM 30 CNGS 150 88 20/290 CNG 30
31 CNGM 31 CNGS 216 127 20/290 CNG 31
40 CNGM 40 CNGS 282 166 20/290 CNG 40
41 CNGM 41 CNGS 360 212 20/290 CNG 41
42 CNGM 42 CNGS 432 254 20/290 CNG 42
43 CNGM 43 CNGS 510 300 20/290 CNG 43
44 CNGM 44 CNGS 750 441 20/290 CNG 44
50 CNGM 50 CNGS 888 522 20/290 CNG 50
51 CNGM 51 CNGS 1176 692 20/290 CNG 51
52 CNGM 52 CNGS 1440 847 20/290 CNG 52
60 CNGM 60 CNGS 1968 1158 20/290 CNG 60
61 CNGM 61 CNGS 2760 1624 20/290 CNG 61
CNGM CNGS
borosilicate micro fi bres
borosilicate micro fi bres fi lter material
0,1 μm 0,01 μm solid particle size purifi cation: down to
1 1 quality class - solids (ISO 8573-1)
2 1 quality class - oils (ISO 8573-1)
1,5 - 65°C 1,5 - 65°C operating temperature range
50/0,725 80/1,160 pressure drop - new element [mbar / psi]
350/5,076 350/5,076 change fi lter cartridge at pressure drop [mbar / psi]
Replace fi lter element at least every 12 months or when pressure drop reaches 350 mbar.
CNG fi lter elements are used for high effi cient removal of solid particles, oil aerosols and water from compressed natural gas.
For any other technical gas please contact producer or your local dealer.
50
painting air filtration
special applications
CKL-
PP
Mic
rofi l
ter
M 0
,1μm
Mic
rofi l
ter
S 0
,01μ
m
Activ
e ca
rbon
A
Ster
ile fi
lter w
ith
activ
e ca
rbon
SFA
Com
pres
sed
air d
ryer
U
ltrap
ac 2
000
-050
Pres
sure
regu
lato
r
Qui
ck co
uplin
g N
r.Model
Connec-
tions
Air fl ow Dimensions (mm)
Nm3/h A B C
PP-107 1/2’’ 155 270 135 276 • • 2
PP-110 1/2’’ 235 270 135 345 • • 2
PP-207 1/2’’ 78 380 135 276 • • • 2
PP-210 1/2’’ 120 380 135 345 • • • 2
PP-307 1/2’’ 78 490 135 276 • • • • 2
PP-310 1/2’’ 120 490 135 345 • • • • 2
PP-407 1/2’’ 78 580 135 276 • • • • 4
PP-410 1/2’’ 120 580 135 345 • • • • 4
PP-507 1/2’’ 78 612 135 370 • • • • 4
PP-510 1/2’’ 120 612 135 440 • • • • 4
PP-607 1/2’’ 78 1150 335 917 • • • • • 4
PP-610 1/2’’ 120 1150 335 917 • • • • • 4
ProPaintsystem
Professional units for high compressed air quality requirements
6 diff erent air qualities available:1- compressed air for lower quality demands (down to 15 μm) 2- compressed air for basic quality demands (down to 0,1 μm)3- compressed air for high quality demands (down to 0,01 μm)4- tech. absolutely clean air (down to 0,1 μm, active carbon)5- technical & breathable air6- compressed air for highest demands (all in one unit)
PP-507PP-510
PP-407PP-410
PP-307PP-310
PP-207PP-210
PP-107PP-110
PP-607PP-610
C
A
B
0 ÷ 16 bar
1,5 ÷ 65 °C
78 ÷ 235 Nm3/h
www.omega-air.si 51
CNGS H2 A2 Flow rate Max. oper.
pressure
[bar/psi]
Filter’s
housing0,01 μm 0,1 μm 0,1 μm Nm3/h scfm
07050 S 07050 H2 07050 A2 78 46 16/232 07050
14050 S 14050 H2 14050 A2 120 70 16/232 14050
12075 S 12075 H2 12075 A2 198 116 16/232 12075
22075 S 22075 H2 22075 A2 335 197 16/232 22075
32075 S 32075 H2 32075 A2 510 300 16/232 32075
50075 S 50075 H2 50075 A2 780 459 16/232 50075
CNGM H2 A2
borosilicate micro fi bres
hopcalite, borosilicate micro fi bres
activated carbon, borosilicate micro fi bres
fi lter material
0,01 μm 0,1 μm 0,1 μm solid particle size purifi cation: down to
1 1 1 quality class - solids (ISO 8573-1)
1 - 0/1 quality class - oils (ISO 8573-1)
1,5 - 65°C 1,5 - 45°C 1,5 - 45°C operating temperature range
80/1,160 see spec. see spec. pressure drop - new element [mbar / psi]
350/5,076 6 months 6 months change fi lter cartridge at pressure drop [mbar / psi]
breathing air filter set
sšpecial applications
0 ÷ 16 bar
1,5 ÷ 45 °C
78 ÷ 780 Nm3/h
DESCRIPTION
B-AIRTM point of use fi lter set has been specifi cally developed for high effi cient preparation of top quality breathing air. On request B-AIRTM fi lter set can be supplied with wall mounting brackets, pressure regulator and quick couplings.
- operating pressure range: 0 - 16 bar (0 - 232 psi)- operating temperature range: 1,5 – 45 °C (35 - 113°F)
APPLICATIONS
· Breathing air
Filter set Connection
Flow rate
(7 bar, 20°C)Dimensions [mm] Mass
[kg]
Filter
elementNm3/h scfm A B C D
B-AIR 0076 1/2’’ 78 46 187 88 20 60 0,7 07050 (S+H2+A2)
B-AIR 0106 3/4’’ 120 70 257 88 20 80 0,8 14050 (S+H2+A2)
B-AIR 0186 1’’ 198 116 263 125 32 100 1,8 12075 (S+H2+A2)
B-AIR 0306 1’’ 335 197 363 125 32 120 2,5 22075 (S+H2+A2)
B-AIR 0476 1 1/2’’ 510 300 461 125 32 140 2,5 32075 (S+H2+A2)
B-AIR 0706 1 1/2’’ 780 459 640 125 32 160 3,2 50075 (S+H2+A2)
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,38 0,5 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
52
filtration
AFs fi lters have been specifi cally developed for applications in paint industry. These fi lters are free of substances that could cause defects in paint aplications and provide, high effi cient removal of water, oil aerosols, hydrocarbons and odour vapors from compressed air systems.
To meet the required compressed air quality appropriate “paint compatible” fi lter element (B, P, R, M, S, A) must be installed into fi lter housing.
- max. operating pressure: 16 bar (232 psi)- operating temperature range: 1,5 – 65 °C (35 - 149 °F)
APPLICATIONS:
• painting applications• automotive industry
0 ÷ 16 bar
1,5 ÷ 65 °C
60 ÷ 2760 Nm3/h
Filter model Connection
Flow rate
at 7 bar(g), 20°CDimensions [mm]
Mass
[kg]
Filter
cartridge
sizeNm3/h scfm A B C D
AFs 0056 3/8’’ 60 35 187 88 20 60 0,7 06050
AFs 0076 1/2’’ 78 46 187 88 20 60 0,7 07050
AFs 0106 3/4’’ 120 70 257 88 20 80 0,8 14050
AFs 0186 1’’ 198 116 263 125 32 100 1,8 12075
AFs 0306 1’’ 335 197 363 125 32 120 2,5 22075
AFs 0476 1 1/2’’ 510 300 461 125 32 140 2,5 32075
AFs 0706 1 1/2’’ 780 459 640 125 32 160 3,2 50075
AFs 0946 2’’ 1000 588 684 163 43 520 5,1 51090
AFs 1506 2’’ 1500 882 935 163 43 770 7,1 76090
AFs 1756 2 1/2’’ 1680 990 935 163 43 770 6,9 76090
AFs 2006 3’’ 2160 1270 795 240 59 630 12,9 51140
AFs 2406 3’’ 2760 1620 1000 240 59 780 14,0 75140
CORRECTION FACTORS
Operating pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction factor 0,38 0,5 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
B
80
C
AD
R 1/2’’
www.omega-air.si 53
Ms SsFlow rate
at 7 bar(g), 20°CMax. oper.
pressure
[bar/psi]
Filter’s housing
0,1 μm 0,01 μm Nm3/h scfm
06050 Ms 06050 Ss 60 35 16/232 AFs 0056
07050 Ms 07050 Ss 78 46 16/232 AFs 0076
14050 Ms 14050 Ss 120 70 16/232 AFs 0106
12075 Ms 12075 Ss 198 116 16/232 AFs 0186
22075 Ms 22075 Ss 335 197 16/232 AFs 0306
32075 Ms 32075 Ss 510 300 16/232 AFs 0476
50075 Ms 50075 Ss 780 459 16/232 AFs 0706
51090 Ms 51090 Ss 1000 588 16/232 AFs 0946
76090 Ms 76090 Ss 1500 882 16/232 AFs 1506
76090 Ms 76090 Ss 1680 990 16/232 AFs 1756
51140 Ms 51140 Ss 2160 1270 16/232 AFs 2006
75140 Ms 75140 Ss 2760 1620 16/232 AFs 2406
Ms Ss
borosilicate micro fi bres
borosilicate micro fi bres fi lter material
0,1 μm 0,01 μm solid particle size purifi cation: down to
1 1 quality class - solids (ISO 8573-1)
2 1 quality class - oils (ISO 8573-1)
1,5 - 65°C 1,5 - 65°C operating temperature range
50/0,725 80/1,160 pressure drop - new element [mbar / psi]
350/5,076 350/5,076 change fi lter cartridge at pressure drop [mbar / psi]
Replace fi lter element at least every 12 months or when pressure drop reaches 350 mbar.
Filter elements have been specifi cally developed for applications in paint industry. Elements are free of substances that could cause defects in paint aplications and provide, high effi cient removal of water, oil aerosols, hydrocarbons and odor vapors from compressed air systems.
54
ZANDERAluminium
end caps
Plastic
end capsZANDER
Aluminium
end caps
Plastic
end capsZANDER
Aluminium
end caps
Plastic
end caps
V 1030 V-PE 2/1 Z ZV06040/P Z 1030 FF 2/1 Z / Y 1030 MF 2/1 Z ZY06040/M
V 1050 V-PE 2/1,5 Z ZV06050/P Z 1050 FF 2/1,5 Z / Y 1050 MF 2/1,5 Z ZY06050/M
V 1070 V-PE 3/1,5 Z ZV07050/P Z 1070 FF 3/1,5 Z / Y 1070 MF 3/1,5 Z ZY07050/M
V 1140 V-PE 5/1,5 Z ZV14050/P Z 1140 FF 5/1,5 Z / Y 1140 MF 5/1,5 Z ZY14050/M
V 2010 V-PE 4/2,5 Z ZV12075/P Z 2010 FF 4/2,5 Z / Y 2010 MF 4/2,5 Z ZY12075/M
V 2020 V-PE 8/2,5 Z ZV22075/P Z 2020 FF 8/2,5 Z / Y 2020 MF 8/2,5 Z ZY22075/M
V 2030 V-PE 12/2,5 Z ZV32075/P Z 2030 FF 12/2,5 Z / Y 2030 MF 12/2,5 Z ZY32075/M
V 2050 V-PE 20/2,5 Z ZV50075/P Z 2050 FF 20/2,5 Z / Y 2050 MF 20/2,5 Z ZY50075/M
V 3050 V-PE 20/3 Z ZV51090/P Z 3050 FF 20/3 Z / Y 3050 MF 20/3 Z ZY51090/M
V 3075 V-PE 30/3 Z ZV76090/P Z 3075 FF 30/3 Z / Y 3075 MF 30/3 Z ZY76090/M
V 5075 V-PE 30/5 Z ZV75140/P Z 5075 FF 30/5 Z / Y 5075 MF 30/5 Z ZY75140/M
ZANDERAluminium
end caps
Plastic
end capsZANDER
Aluminium
end caps
Plastic
end caps
X 1030 SMF 2/1 Z ZS06040/A A 1030 AK 2/1 Z ZA06040/A
X 1050 SMF 2/1,5 Z ZS06050/A A 1050 AK 2/1,5 Z ZA06050/A
X 1070 SMF 3/1,5 Z ZS07050/A A 1070 AK 3/1,5 Z ZA07050/A
X 1140 SMF 5/1,5 Z ZS14050/A A 1140 AK 5/1,5 Z ZA14050/A
X 2010 SMF 4/2,5 Z ZS12075/A A 2010 AK 4/2,5 Z ZA12075/A
X 2020 SMF 8/2,5 Z ZS22075/A A 2020 AK 8/2,5 Z ZA22075/Al
X 2030 SMF 12/2,5 Z ZS32075/A A 2030 AK 12/2,5 Z ZA32075/A
X 2050 SMF 20/2,5 Z ZS50075/A A 2050 AK 20/2,5 Z ZA50075/A
X 3050 SMF 20/3 Z ZS51090/A A 3050 AK 20/3 Z ZA51090/A
X 3075 SMF 30/3 Z ZS76090/A A 3075 AK 30/3 Z ZA76090/A
X 5075 SMF 30/5 Z ZS75140/A A 5075 AK 30/5 Z ZA75140/A
DOMNICK
HUNTER
Aluminium
end caps
Plastic
end caps
DOMNICK
HUNTER
Aluminium
end caps
Plastic
end caps
PF 009 V-PE 2/0,5 DH DHPF009/P AO 009 FF 2/0,5 DH DHAO009/M
PF 017 V-PE 3/1,5 DH DHPF017/P AO 017 FF 3/1,5 DH DHAO017/M
PF 030 V-PE 4/1,5 DH DHPF030/P AO 030 FF 4/1,5 DH DHAO030/M
PF 058 V-PE 6/2,5 DH DHPF058/P AO 058 FF 6/2,5 DH DHAO058/M
PF 145 V-PE 10/2,5 DH DHPF145/P AO 145 FF 10/2,5 DH DHAO145/M
PF 195 V-PE 12/3 DH / AO 195 FF 12/3 DH /
PF 220 V-PE 12/3-2 DH DHPF220/P AO 220 FF 12/3-2 DH DHAO220/M
PF 330 V-PE 24/3-2 DH DHPF330/P AO 330 FF 24/3-2 DH DHAO330/M
PF 430 V-PE 15/4-2,5 DH DHPF430/P AO 430 FF 15/4-2,5 DH DHAO430/M
PF 620 V-PE 24/4-2,5 DH DHPF620/P AO 620 FF 24/4-2,5 DH DHAO620/M
DOMNICK
HUNTER
Aluminium
end caps
Plastic
end caps
DOMNICK
HUNTER
Aluminium
end caps
Plastic
end caps
AA 009 MF 2/0,5 DH DHAAO009/S ASC 009 AK 2/0,5 DH DHASCO009/A
AA 017 MF 3/1,5 DH DHAAO017/S ASC 017 AK 3/1,5 DH DHASCO017/A
AA 030 MF 4/1,5 DH DHAAO030/S ASC 030 AK 4/1,5 DH DHASCO030/A
AA 058 MF 6/2,5 DH DHAAO058/S ASC 058 AK 6/2,5 DH DHASCO058/A
AA 145 MF 10/2,5 DH DHAAO145/S ASC 145 AK 10/2,5 DH DHASCO145/A
AA 195 MF 12/3 DH / ASC 195 AK 12/3 DH /
AA 220 MF 12/3-2 DH DHAAO220/S ASC 220 AK 12/3-2 DH DHASCO220/A
AA 330 MF 24/3-2 DH DHAAO330/S ASC 330 AK 24/3-2 DH DHASCO330/A
AA 430 MF 15/4-2,5 DH DHAAO430/S ASC 430 AK 15/4-2,5 DH DHASCO430/A
AA 620 MF 24/4-2,5 DH DHAAO620/S ASC 620 AK 24/4-2,5 DH DHASCO620/A
alternative filter cartridges
alternative solutions
ZANDER
DOMNICK HUNTER
www.omega-air.si 55
HIROSS Aluminium
end caps
Plastic
end caps
HIROSS Aluminium
end caps
Plastic
end caps-1998 -1999 -2000 -1998 -1999 -2000
004 Q 006 Q 010 Q / HQ004/P 004 P 006 P 010 P / HQ004/M
007 Q 009 Q 016 Q / HQ007/P 007 P 009 P 016 P / HQ007/M
015 Q 020 Q 022 Q PE 6/1,5 HS HQ015/P 015 P 020 P 022 P FF 6/1,5 HS HQ015/M
024 Q 024 Q 030 Q PE 6/2,5 HS HQ024/P 024 P 024 P 030 P FF 6/2,5 HS HQ024/M
035 Q 035 Q 045 Q PE 8/1,5 HS HQ035/P 035 P 035 P 045 P FF 8/1,5 HS HQ035/M
060 Q 060 Q 072 Q PE 14/2,5 HS HQ060/P 060 P 060 P 072 P FF 14/2,5 HS HQ060/M
090 Q 110 Q 135 Q PE 15/3 HS HQ090/P 090 P 110 P 135 P FF 15/3 HS HQ090/M
120 Q 151 Q 205 Q PE 24/3 HS HQ120/P 120 P 151 P 205 P FF 24/3 HS HQ120/M
150 Q 180 Q 250 Q PE 30/3 HS HQ150/P 150 P 180 P 250 P FF 30/3 HS HQ150/M
240 Q 280 Q 280 Q / HQ240/P 240 P 280 P 280 P / HQ240/M
HIROSS Aluminium
end caps
Plastic
end caps
HIROSS Aluminium
end caps
Plastic
end caps-1998 -1999 -2000 -1998 -1999 -2000
004 S 006 S 010 S / HQ004/S 004 C 006 C 010 C / HQ004/A
007 S 009 S 016 S / HQ007/S 007 C 009 C 016 C / HQ007/A
015 S 020 S 022 S MF 6/1,5 HS HQ015/S 015 C 020 C 022 C AK 6/1,5 HS HQ015/A
024 S 024 S 030 S MF 6/2,5 HS HQ024/S 024 C 024 C 030 C AK 6/2,5 HS HQ024/A
035 S 035 S 045 S MF 8/1,5 HS HQ035/S 035 C 035 C 045 C AK 8/1,5 HS HQ035/A
060 S 060 S 072 S MF 14/2,5 HS HQ060/S 060 C 060 C 072 C AK 14/2,5 HS HQ060/A
090 S 110 S 135 S MF 15/3 HS HQ090/S 090 C 110 C 135 C AK 15/3 HS HQ090/A
120 S 151 S 205 S MF 24/3 HS HQ120/S 120 C 151 C 205 C AK 24/3 HS HQ120/A
150 S 180 S 250 S MF 30/3 HS HQ150/S 150 C 180 C 250 C AK 30/3 HS HQ150/A
240 S 280 S 280 S / HQ240/S 240 C 280 C 280 C / HQ240/A
OMI
≤ 2003
OMI
> 2003
Plastic
end caps
OMI
≤ 2003
OMI
> 2003
Plastic
end caps
0004QF 0005QF OQF0004/P 0004PF 0005PF OPF0004/M
0008QF 0010QF OQF0008/P 0008PF 0010PF OPF0008/M
0016QF 0018QF OQF0016/P 0016PF 0018PF OPF0016/M
/ 0030QF OQF0030/P / 0030PF OPF0030/M
0025QF 0034QF OQF0025/P 0025PF 0034PF OPF0025/M
0036QF 0050QF OQF0036/P 0036PF 0050PF OPF0036/M
/ 0072QF OQF0072/P / 0072PF OPF0072/M
0060QF 0095QF OQF0060/P 0060PF 0095PF OPF0060/M
0070QF / OQF0070/P 0070PF / OPF0070/M
0090QF 0125QF OQF0090/P 0090PF 0125PF OPF0090/M
0120QF 0165QF OQF0120/P 0120PF 0165PF OPF0120/M
/ 0190QF OQF0190/P / 0190PF OPF0190/M
0185QF 0220QF OQF0185/P 0185PF 0220PF OPF0185/M
/ 0280QF OQF0280/P / 0280PF OPF0280/M
/ 0350QF OQF0350/P / 0350PF OPF0350/M
/ 0440QF OQF0440/P / 0440PF OPF0440/M
OMI
≤ 2003
OMI
> 2003
Plastic
end caps
OMI
≤ 2003
OMI
> 2003
Plastic
end caps
0004HF 0005HF OHF0004/S 0004CF 0005CF OCF0004/A
0008HF 0010HF OHF0008/S 0008CF 0010CF OCF0008/A
0016HF 0018HF OHF0016/S 0016CF 0018CF OCF0016/A
/ 0030HF OHF0030/S / 0030CF OCF0030/A
0025HF 0034HF OHF0025/S 0025CF 0034CF OCF0025/A
0036HF 0050HF OHF0036/S 0036CF 0050CF OCF0036/A
/ 0072HF OHF0072/S / 0072CF OCF0072/A
0060HF 0095HF OHF0060/S 0060CF 0095CF OCF0060/A
0070HF / OHF0070/S 0070CF / OCF0070/A
0090HF 0125HF OHF0090/S 0090CF 0125CF OCF0090/A
0120HF 0165HF OHF0120/S 0120CF 0165CF OCF0120/A
/ 0190HF OHF0190/S / 0190CF OCF0190/A
0185HF 0220HF OHF0185/S 0185CF 0220CF OCF0185/A
/ 0280HF OHF0280/S / 0280CF OCF0280/A
/ 0350HF OHF0350/S / 0350CF OCF0350/A
/ 0440HF OHF0440/S / 0440CF OCF0440/A
alternative filter cartridges
alternative solutions
HIROSS
OMI
56
DONALDSONAluminium
end caps
Plastic
end capsDONALDSON
Aluminium
end caps
Plastic
end caps
PE 02/05 PE 02/05 UPE0205 FF 02/05 FF 02/05 UFF0205
PE 03/05 PE 03/05 UPE0305 FF 03/05 FF 03/05 UFF0305
PE 03/10 PE 03/10 UPE0310 FF 03/10 FF 03/10 UFF0310
PE 04/10 PE 04/10 UPE0410 FF 04/10 FF 04/10 UFF0410
PE 04/20 PE 04/20 UPE0420 FF 04/20 FF 04/20 UFF0420
PE 05/20 PE 05/20 UPE0520 FF 05/20 FF 05/20 UFF0520
PE 05/25 PE 05/25 UPE0525 FF 05/25 FF 05/25 UFF0525
PE 07/25 PE 07/25 UPE0725 FF 07/25 FF 07/25 UFF0725
PE 07/30 PE 07/30 UPE0730 FF 07/30 FF 07/30 UFF0730
PE 10/30 PE 10/30 UPE1030 FF 10/30 FF 10/30 UFF1030
PE 15/30 PE 15/30 UPE1530 FF 15/30 FF 15/30 UFF1530
PE 20/30 PE 20/30 UPE2030 FF 20/30 FF 20/30 UFF2030
PE 30/30 PE 30/30 UPE3030 FF 30/30 FF 30/30 UFF3030
PE 30/50 PE 30/50 UPE3050 FF 30/50 FF 30/50 UFF3050
DONALDSONAluminium
end caps
Plastic
end capsDONALDSON
Aluminium
end caps
Plastic
end capsDONALDSON
Aluminium
end caps
Plastic
end caps
SMF 02/05 SMF 02/05 USMF0205 MF 02/05 MF 02/05 UMF0205 AK 02/05 AK 02/05 UAK0205
SMF 03/05 SMF 03/05 USMF0305 MF 03/05 MF 03/05 UMF0305 AK 03/05 AK 03/05 UAK0305
SMF 03/10 SMF 03/10 USMF0310 MF 03/10 MF 03/10 UMF0310 AK 03/10 AK 03/10 UAK0310
SMF 04/10 SMF 04/10 USMF0410 MF 04/10 MF 04/10 UMF0410 AK 04/10 AK 04/10 UAK0410
SMF 04/20 SMF 04/20 USMF0420 MF 04/20 MF 04/20 UMF0420 AK 04/20 AK 04/20 UAK0420
SMF 05/20 SMF 05/20 USMF0520 MF 05/20 MF 05/20 UMF0520 AK 05/20 AK 05/20 UAK0520
SMF 05/25 SMF 05/25 USMF0525 MF 05/25 MF 05/25 UMF0525 AK 05/25 AK 05/25 UAK0525
SMF 07/25 SMF 07/25 USMF0725 MF 07/25 MF 07/25 UMF0725 AK 07/25 AK 07/25 UAK0725
SMF 07/30 SMF 07/30 USMF0730 MF 07/30 MF 07/30 UMF0730 AK 07/30 AK 07/30 UAK0730
SMF 10/30 SMF 10/30 USMF1030 MF 10/30 MF 10/30 UMF1030 AK 10/30 AK 10/30 UAK1030
SMF 15/30 SMF 15/30 USMF1530 MF 15/30 MF 15/30 UMF1530 AK 15/30 AK 15/30 UAK1530
SMF 20/30 SMF 20/30 USMF2030 MF 20/30 MF 20/30 UMF2030 AK 20/30 AK 20/30 UAK2030
SMF 30/30 SMF 30/30 USMF3030 MF 30/30 MF 30/30 UMF3030 AK 30/30 AK 30/30 UAK3030
SMF 30/50 SMF 30/50 USMF3050 MF 30/50 MF 30/50 UMF3050 AK 30/50 AK 30/50 UAK3050
DONALDSONAluminium
end caps
Plastic
end capsDONALDSON
Aluminium
end caps
Plastic
end caps
PE 03/1 PE 03/1 UPE031/P FF 03/1 FF 03/1 UFF031/M
PE 03/1,5 PE 03/1,5 UPE031.5/P FF 03/1,5 FF 03/1,5 UFF031.5/M
PE 04/1,5 PE 04/1,5 UPE041.5/P FF 04/1,5 FF 04/1,5 UFF041.5/M
PE 04/2,5 PE 04/2,5 UPE042.5/P FF 04/2,5 FF 04/2,5 UFF042.5/M
PE 05/2,5 PE 05/2,5 UPE052.5/P FF 05/2,5 FF 05/2,5 UFF052.5/M
PE 05/3 PE 05/3 UPE053/P FF 05/3 FF 05/3 UFF053/M
PE 10/3 PE 10/3 UPE103/P FF 10/3 FF 10/3 UFF103/M
PE 15/3 PE 15/3 UPE153/P FF 15/3 FF 15/3 UFF153/M
PE 20/3 PE 20/3 UPE203/P FF 20/3 FF 20/3 UFF203/M
PE 30/3 PE 30/3 UPE303/P FF 30/3 FF 30/3 UFF303/M
PE 30/5 PE 30/5 UPE305/P FF 30/5 FF 30/5 UFF305/M
DONALDSONAluminium
end caps
Plastic
end capsDONALDSON
Aluminium
end caps
Plastic
end capsDONALDSON
Aluminium
end caps
Plastic
end caps
SMF 03/1 SMF 03/1 USMF031/M MF 03/1 MF 03/1 UMF031/M AK 03/1 AK 03/1 UAK031/A
SMF 03/1,5 SMF 03/1,5 USMF031.5/M MF 03/1,5 MF 03/1,5 UMF031.5/M AK 03/1,5 AK 03/1,5 UAK031.5/A
SMF 04/1,5 SMF 04/1,5 USMF041.5/M MF 04/1,5 MF 04/1,5 UMF041.5/M AK 04/1,5 AK 04/1,5 UAK041.5/A
SMF 04/2,5 SMF 04/2,5 USMF042.5/M MF 04/2,5 MF 04/2,5 UMF042.5/M AK 04/2,5 AK 04/2,5 UAK042.5/A
SMF 05/2,5 SMF 05/2,5 USMF052.5/M MF 05/2,5 MF 05/2,5 UMF052.5/M AK 05/2,5 AK 05/2,5 UAK052.5/A
SMF 05/3 SMF 05/3 USMF053/M MF 05/3 MF 05/3 UMF053/M AK 05/3 AK 05/3 UAK053/A
SMF 10/3 SMF 10/3 USMF103/M MF 10/3 MF 10/3 UMF103/M AK 10/3 AK 10/3 UAK103/A
SMF 15/3 SMF 15/3 USMF153/M MF 15/3 MF 15/3 UMF153/M AK 15/3 AK 15/3 UAK153/A
SMF 20/3 SMF 20/3 USMF203/M MF 20/3 MF 20/3 UMF203/M AK 20/3 AK 20/3 UAK203/A
SMF 30/3 SMF 30/3 USMF303/M MF 30/3 MF 30/3 UMF303/M AK 30/3 AK 30/3 UAK303/A
SMF 30/5 SMF 30/5 USMF305/M MF 30/5 MF 30/5 UMF305/M AK 30/5 AK 30/5 UAK305/A
alternative filter cartridges
alternative solutions
DONALDSON -90 series
DONALDSON -80 series
www.omega-air.si 57
HANKISON KAESER DONALDSON HANKISON KAESER DONALDSON
E9-12 E-B-6 VF 12 E3-12 E-F-6 SMF 12
E9-16 E-B-10 VF 16 E3-16 E-F-10 SMF 16
E9-20 E-B-18 VF 20 E3-20 E-F-18 SMF 20
E9-24 E-B-28 VF 24 E3-24 E-F-28 SMF 24
E9-28 E-B-48 VF 28 E3-28 E-F-48 SMF 28
E9-32 E-B-71 VF 32 E3-32 E-F-71 SMF 32
E9-36 E-B-107 VF 36 E3-36 E-F-107 SMF 36
E9-40 E-B-138 VF 40 E3-40 E-F-138 SMF 40
E9-44 E-B-177 VF 44 E3-44 E-F-177 SMF 44
E9-48 E-B-221 VF 48 E3-48 E-F-221 SMF 48
E9-52 E-B-185 VF PV E3-52 E-F-185 SMF PV
E9-54 E-B-283 VF 54 E3-54 E-F-283 SMF 54
HANKISON KAESER DONALDSON HANKISON KAESER DONALDSON HANKISON KAESER DONALDSON
E7-12 E-C-6 FF 12 E1-12 E-G-6 AKP 12 E5-12 E-E-6 MF 12
E7-16 E-C-10 FF 16 E1-16 E-G-10 AKP 16 E5-16 E-E-10 MF 16
E7-20 E-C-18 FF 20 E1-20 E-G-18 AKP 20 E5-20 E-E-18 MF 20
E7-24 E-C-28 FF 24 E1-24 E-G-28 AKP 24 E5-24 E-E-28 MF 24
E7-28 E-C-48 FF 28 E1-28 E-G-48 AKP 28 E5-28 E-E-48 MF 28
E7-32 E-C-71 FF 32 E1-32 E-G-71 AKP 32 E5-32 E-E-71 MF 32
E7-36 E-C-107 FF 36 E1-36 E-G-107 AKP 36 E5-36 E-E-107 MF 36
E7-40 E-C-138 FF 40 E1-40 E-G-138 AKP 40 E5-40 E-E-138 MF 40
E7-44 E-C-177 FF 44 E1-44 E-G-177 AKP 44 E5-44 E-E-177 MF 44
E7-48 E-C-221 FF 48 E1-48 E-G-221 AKP 48 E5-48 E-E-221 MF 48
E7-52 E-C-185 FF PV E1-52 E-G-185 AKP PV E5-52 E-E-185 MF PV
E7-54 E-C-283 FF 54 E1-54 E-G-283 AKP 54 E5-54 E-E-283 MF 54
BOGEPlastic
end capsBOGE
Plastic
end capsBOGE
Plastic
end caps
1/5 V 1/5 P 1/5 FP 1/5 S 1/5 A 1/5 A
1/10 V 1/10 P 1/10 FP 1/10 S 1/10 A 1/10 A
1/12 V 1/12 P 1/12 FP 1/12 S 1/12 A 1/12 A
1/20 V 1/20 P 1/20 FP 1/20 S 1/20 A 1/20 A
1/30 V 1/30 P 1/30 FP 1/30 S 1/30 A 1/30 A
1/50 V 1/50 P 1/50 FP 1/50 S 1/50 A 1/50 A
1/80 V 1/80 P 1/80 FP 1/80 S 1/80 A 1/80 A
1/120 V 1/120 P 1/120 FP 1/120 S 1/120 A 1/120 A
1/160 V 1/160 P 1/160 FP 1/160 S 1/160 A 1/160 A
1/250 V 1/250 P 1/250 FP 1/250 S 1/250 A 1/250 A
alternative filter cartridges
alternative solutions
HANKISON
BOGE
58
90. series 80. series
DONALDSON ZANDER DOMNICKHUNTER DONALDSON ZANDER DOMNICK
HUNTER DONALDSON ZANDER DOMNICKHUNTER
P-SRF 03/10 PST-R 03/10 ME 03/10 SRF 02/10 ST-R 03/10 MER 02/10 SRF 3/1 ST-R 03/1 ME 3/1
P-SRF 04/10 PST-R 04/10 ME 02/10 SRF 03/10 ST-R 04/10 MER 03/10 SRF 3/1,5 ST-R 03/1,5 ME 3/1.5
P-SRF 04/20 PST-R 04/20 ME 04/20 SRF 04/20 ST-R 04/20 MER 04/20 SRF 4/1,5 ST-R 04/1,5 ME 4/1.5
P-SRF 05/20 PST-R 05/20 ME 05/20 SRF 05/20 ST-R 05/20 MER 05/20 SRF 4/2,5 ST-R 04/2,5 ME 4/2.5
P-SRF 05/25 PST-R 05/25 ME 05/25 SRF 05/25 ST-R 05/25 MER 05/25 SRF 5/2,5 ST-R 05/2,5 ME 5/2.5
P-SRF 07/25 PST-R 07/25 ME 07/25 SRF 07/25 ST-R 07/25 MER 07/25 SRF 5/3 ST-R 05/3 ME 5/3
P-SRF 07/30 PST-R 07/30 ME 07/30 SRF 07/30 ST-R 10/30 MER 07/30 SRF 10/3 ST-R 10/3 ME 10/3
P-SRF 10/30 PST-R 10/30 ME 10/30 SRF 10/30 ST-R 15/30 MER 10/30 SRF 15/3 ST-R 15/3 ME 15/3
P-SRF 15/30 PST-R 15/30 ME 15/30 SRF 15/30 ST-R 20/30 MER 15/30 SRF 20/3 ST-R 20/3 ME 20/3
P-SRF 20/30 PST-R 20/30 ME 20/30 SRF 20/30 ST-R 30/30 MER 20/30 SRF 30/3 ST-R 30/3 ME 30/3
P-SRF 30/30 PST-R 30/30 ME 30/30 SRF 30/30 ST-R 30/50 MER 30/30 SRF 30/5 ST-R 30/5 ME 30/5
P-SRF 30/50 PST-R 30/50 ME 30/50 SRF 30/50 ST-R 30/50 MER 30/50
OEM production of intake air fi lters for every types of compressors.
Alternative sterile fi lter cartridges
alternative filter cartridges
alternative solutions
Intake air fi lters
www.omega-air.si 59
H
D
L
H
D
Standard equipment:
• anticorrosion protection with basic colour painting and fi nal painting,• CE - certfi cate (according to PED CE module H, H1), • revision opening (sizes 200 and upper),• supporting legs,• connections for optional equipment,
* ASME certifi cate code U, UM on request!
SizeVolume
(l)
Connections number and dimensions Dimensions (mm)Max.
pressure
(bar)
Mass
(kg)
1/2
’’
3/4
’’
1’’
6/4
’’
2’’
DN
50
DN
80
DN
10
0
DN
15
0
H D L
Vertical pressure vessels
50 47 7 - - - - - - - - 920 300 - 13 25
100 101 6 - - - 1 - - - - 1375 350 - 13 45
150 136 6 - - - 1 - - - - 1395 400 - 13 55
200 199 3 - 4 - - - - - - 1430 480 - 13 85
300 287 1 2 4 - - - - - - 1930 480 - 13 115
500 496 1 2 4 - - - - - - 2025 622 - 13 135
750 739 1 2 4 - - - - - - 2090 750 - 13 170
1000 975 1 - 2 4 - - - - - 2140 850 - 13 260
1500 1368 1 - 2 - 4 - - - - 2295 1000 - 13 310
2000 1853 1 - 2 - 4 - - - - 2370 1150 - 13 460
3000 2825 1 - 2 - 4 - - - - 2905 1250 - 13 630
4000 4028 1 - 2 - - - 4 - - 3915 1250 - 13 810
5000 5121 1 - 2 - - - 4 - - 3915 1400 - 13 1350
6000 5801 1 - 2 - - - - 4 - 3510 1600 - 13 1750
8000 7707 1 - 2 - - - - 4 - 4105 1700 - 13 2190
10000 9953 1 - 2 - - - - 4 - 5200 1700 - 10 2500
15000 15498 1 - 1 - - 1 - - 4 4860 2200 - 10 3750
20000 21073 1 - 1 - - 1 - - 4 6360 2200 - 10 4710
25000 24790 1 - 1 - - 1 - - 4 7360 2200 - 10 5360
Horizontal pressure vessels
50 47 6 - - - - - - - - 400 300 775 13 25
100 101 5 - - - 1 - - - - 505 350 1205 13 45
150 136 5 - - - 1 - - - - 550 400 1220 13 55
200 199 3 - 3 - - - - - - 635 480 1265 13 85
300 287 1 2 3 - - - - - - 625 480 1770 13 115
500 496 1 2 - 3 - - - - - 820 622 1835 13 135
750 739 1 2 - 3 - - - - - 1025 750 1890 13 170
1000 975 1 - 2 3 - - - - - 1130 850 1935 13 260
1500 1368 1 - 2 - 3 - - - - 1275 1000 2000 13 310
2000 1853 1 - 2 - 3 - - - - 1500 1150 2100 13 460
3000 2825 1 - 2 - - - 3 - - 1600 1250 3100 13 630
4000 4028 1 - 2 - - - 3 - - 1600 1250 3600 13 810
5000 5121 1 - 2 - - - 3 - - 1750 1400 3665 13 1350
6000 5801 1 - 2 - - - - 3 - 1950 1600 3250 13 1750
8000 7707 1 - 2 - - - - 3 - 2050 1700 3810 13 2190
10000 9953 1 - 2 - - - - 3 - 2050 1700 4810 10 2500
15000 15498 1 - 1 - - 1 - - 3 2550 2200 4600 10 3750
20000 21073 1 - 1 - - 1 - - 3 2550 2200 6100 10 4710
25000 24790 1 - 1 - - 1 - - 3 2550 2200 7100 10 5360
Optional equipment for pressure vessel consists of:
• Pressure release safety valve with certifi cate.• Pressure gauge with release valve and quick coupling.• Input and output ball valves for compressed air.• Avtomatic condensate drain with release connection and shut-
off valve ( sizes 500 and upper).• Condensate drain pipe.• Plugs for unused connections.• Epoxi coating 70 - 80 micron.• Hot-dipp galvanizing (up to size 10000).
Horizontal & vertical pressure vessels up to 20.000 ltr.
other products
60
other products
Oil separation
Oil separators are OEM products, which are factory integrated into compressors.
Oil separators can be produced by customers technical drawings according to ISO CE-PED or ASME standards for pressure vessels.
www.omega-air.si 61
BS 12-3,5
BS12-3,5 is ‘‘all in one’’ solution for petrol stations, which includes compressor, air connection and water connection in one - compact stainless steel housing.It is an ideal solution for all new petrol stations with centralized air-water supply station.Anti freezing heater assures operating even in temperatures under 0 °C. It is equipped with pressure manometer, which indicates the pressure in pressure vessel.
AWS is ‘‘all in one’’ solution for petrol stations, which includes compressor, air connection and water connection in one - compact stainless steel housing. Integrated controler enables precise and simple adjustment of tyres pressure. Anti freezing heater assures operating even in temperatures under 0 °C.
PETRO-PACK is compressor designed for petrol station applications. It is perfect solution for stations, where is no place for inside installation.Compressor’s cover is made of durable stainless steel sheet. Key lock protects compressor against unauthorized intervention to inside components. Sound protection mounted on cover plates enables installation nearby other buildings. All connections are ground mounted.
BS Tower is designed for compressed air and water maintenance of cars, trucks and other vechicles. It is perfect for systems, where compressed air and water systems are already provided. BS Tower is made of durable stainless steel sheet, which is perfect for variable weather conditions.
Size BS 12-3.5 AWS PETRO-PACK BS TOWER
Max. operating pressure 12 bar 10 bar 12 bar 0 - 12 bar
Flow capacity (ISO 1217) 350 Nl/min 170 Nl/min 350 Nl/min -
Pressure vessel capacity 25 ltr 17 ltr 25 ltr -
Electric motor power 1,8 kW 1,5 kW 2,2 kW -
Power supply 230 V / 50 Hz 230 V / 50 Hz 400 V / 50 Hz 230 V / 50 Hz
Sound level (A) 1m 67 ± 2 dB 68 ± 2 dB 67 ± 2 dB -
Operating temperature -15 to +45 °C -15 to +45 °C -15 to +45 °C -15 to +45 °C
Electric heater power 10 W 10 W 10 W 10 W
Hose length 8 m 8 m - 8 m
AWS
PETRO-PACK
BS Tower
other products
62
Terrain compressors
CB 600
Features:
- compression unit with cast iron cylinder (two stage compression),
- petrol engine,- suction fi lter,- compressed air cooling system,- two pressure vessels with CE certifi cate,- certifi ed safety valve,- ait treatment unit with couplings and pressure gauge,- non-returning valve with regulating valve,- transport tyres,- condensate drain valve,- separated connections for pneumatic tools,- automatic operating control,- high air capacity,- rough construction,- max. pressure control (up to 10 bar) - option,- pneumatic tool oiling,- remarkable mobile,- easy transport and use.
Technical data: - pressure vessel capacity: 50+50 ltr - max. operating pressure: 10 bar - capacity (ISO 1217): 600 Nl/min - max. speed: 900 rpm - cylinder/piston/stage Nr.: 1 / 2 / 2 - engine type: Honda GX 270- main shaft power: 9 HP - working volume: 270 cm3 - fuel: unleaded petrol 95 - engine start: manual - dimensions L/B/H: 1070 / 920 / 1100 mm - mass: 173 kg
Compressor with petrol engine
CD 600
Features:
- compression unit with cast iron cylinder (two stage compression),
- diesel engine,- suction fi lter,- compressed air cooling system,- two pressure vessels with CE certifi cate,- certifi ed safety valve,- ait treatment unit with couplings and pressure gauge,- non-returning valve with regulating valve,- transport tyres,- condensate drain valve,- separated connections for pneumatic tools,- automatic operating control,- rough construction,- max. pressure control (up to 10 bar) - option,- pneumatic tool oiling,- remarkable mobile,- easy transport and use.
Technical data: - pressure vessel capacity: 50+50 ltr - max. operating pressure: 10 bar - capacity (ISO 1217): 600 Nl/min - power transmittion: belt- max. speed: 900 rpm - cylinder/piston/stage Nr.: 1 / 2 / 2- main shaft power: 8 HP - working volume: 349 cm3 - fuel: diesel - engine start: manual - dimensions L/B/H: 1070 / 920 / 1100 mm - mass: 173 kg
Compressor with diesel engine
other products
www.omega-air.si 63
Omega Air d.o.o. is a producer of container compressed air stations. Completely equipped unit is a perfect solution for compressed air supply in the case of compressor breakdown.
Benefi ts:
- all in one unit (compressors, dryer, pressure vessel, fi lters, separators...),
- compressed air hireing in the case of service or refi t,- quick response in the case of compressor breakdown,- guarantee for clean air,- easy connection to existent compressed air system,- exterior placing regardless to weather conditions, - possibility for permanent placing as basic compressed
air station, - easy transport with forklift and truck.
other products
64
OmegaAir
Moulds constructionMoulds construction
The management of aluminium dye casting
moulds and plastic products production gives
positive efects, which results in high quality of
components and quick reply to tools construction
changes.
CAD-CAM technology is a guarantee for techology
perfected productc of highest quality.
Filter cartridges Filter cartridges
constructionconstruction
20 years of experiences on fi lter cartridges
designing put our company to top quality world
producers. Filter cartridge is the most important
part in compressed air purifi cation. Thatswhy we
perform fi lter integrity test with DOP (Dispersed Oil
Particulate) device.
Particulate counting and dimension controlling
device is the next step, which we perform to
achieve top quality products.
TechnologyTechnology
Introducing new technologies and permanent
investing in development give optimal solutions.
Our people work closely with the business to
develop solutions that enable them and their
clients to stay ahead of their game.
Technology is a place where communication and
innovation allow us to provide an unbeatable
service to our clients.
DesignDesign
Our experts develop tailored solutions for
our clients, no matter how demanding their
requirements are.
Wide range of experiences, technical know-how
and innovations are key features, making the best
solutions possible.
ElectronicsElectronics
Our electronic team works closely with our clients
to invent, develop and build real-world technology
solutions to some of their hardest problems, as
well as providing professional support services for
those solutions throughout their operational lives.
Through the system testing and optimisation we
try to achieve the reduction of device operating
costs.
Quality controlQuality control
Dimension control on CNC coordinate measuring
machine is only one way to high quality of
products.
Executing of all demands of ISO and ASME
standards procedures is a guarantee for top
quality production.
www.omega-air.si 65
OmegaAir
Plastics departmentPlastics department
All our plastic procucts are produced in our plastic
department, moulds are designed and produced
in our toolroom department. This is the best way
for effi cient supervision of production processes
and products quality.
Mechanical departmentMechanical department
High technology CNC machines are assurance for
high quality of our products.
Contemporary CNC machining centres, CNC
lathes, high productivity CNC turning centres
and manipulation robot are the part of modern
equipped mechanical department.
Filtration departmentFiltration department
Filtration department masters complete
procedure of fi lter cartridges production (steel
mesh welding, fi lter cartriges assembling, 100 %
effi ciency testing, end cap engraving... ).
Filter media pleatingFilter media pleating
Contemporary pleating machines produces
hundreds metres of pleated fi lter media, which is
the essential part of each fi lter cartridge.
Day by day, year by year, their mission is the same.
Pleating the enormous quantity of fi lter media.
Moulds productionMoulds production
CNC wire cut machine, CNC die sinking machine,
CNC machining centre, CNC lathe and grinding
machine are only the part of contemporary
designed department for moulds production.
Equipment departmentEquipment department
Modern equipped department has signifi cant
tasks which are composing, checking, testing of
products in real conditions, and packaging of
compressed air equipment products.
The most important task is fi nal control check,
which is meant for extra elimination of faulty
products.
66
... from A to Z .
Sport clubSport club
Stress - so many times stated word.
We know the way to avoid it.
Sport! It is also the great way for team building.
30 % of employments is affi liated in company’s
Sport and recreational club, which includes three
sections:
- cycling,
- running,
- mountaineering.
Logistics & TransportLogistics & Transport
Three trucks, forklifts, big warehouses and great
staff is a guarantee, that your goods are always
treated with care.
24 hours Service24 hours Service
Breakdown at weekend? No problem, if you are
the customer of Omega Air. Our service staff is 24
hours in state of preparation.
Every member of service staff team has his
own, wholly equipped vehicle for emergency
intervention.
EngineeringEngineering
The high knowledge range of our experts assures
high level of realised operations reliability. Our
engineering services include economic analyses,
feasibility studies, process design, project
engineering, and construction engineering.
We are recognized for our expertise in a wide
range of disciplines, mechanical, civil, structural,
control systems, electrical, piping and process
engineering.
Welding departmentWelding department
Certifi ed welders and certifi ed production
procedures are the guarantee for excellent
products.
Certifi cations according to PED CE H1 and H
module, ASME U and UM code confi rms the
highest quality of our products and services.
AssemblyAssembly
Hundreds of satisfi ed customers are big enough
reason to choose our company for providing the
system components assembly. Our own team of
competent experts with years of practice is always
a good choice.
www.omega-air.si 67
CUSTOMISED PRODUCTS
A large part of our manufacturing capacity is suited for customized products. We take part in the developing of the products together with our customers.
If you have a project in our range of products and need a co-operating partner do not hesitate to contact us.
GENERAL TERMS OF SALES
General conditions: Exclusively valid “The general sales conditions” of company Omega Air d.o.o. Ljubljana.
Terms of delivery: Incoterms EXW Ljubljana, Slovenia, packing included.
Terms of payment: Payment in advance if not otherwise agreed. Currency is EUR.
Warranty: One year from date of delivery. Warranty valids only if the product is used in accordance with its instruction manual. Other costs such
as labour costs are not included.
Changes: We reserve the right for typing errors and right to change the prices, conditions and technical specifi cations of the products without
previous announcement.
Packing and packing waste: The customer in the recipient country is responsible for the recycling of packaging and disposal of waste electrical equipment in
accordance with Directive 94/62/EC – Packing and Packing Waste and Directive 2002/96/EC Waste Electrical and Electronic Equipment
(WEEE).
Right of ownership: Delivered products remain in our possession until full payment has been settled.
The above mentioned sales terms and conditions are only for information. All other details are defi ned in writen agreement between contract parties.
Europe,Slovenia
Ljubljana
Ljubljana ringExit-Ljubljana zahod
№ 35
Austria Austria
Croatia
Italy
Exit № 35
OMEGA AIR d.o.o. Ljubljana Cesta Dolomitskega odreda 10 SI-1000, Ljubljana, Slovenia
GPS coordinates: N: 46° 2’ 27.13’’ E: 14° 27’ 59.46’’
LJUBLJANA
OMEGA AIR d. o. o. LjubljanaCesta Dolomitskega odreda 10
1000 Ljubljana, Sloveniatel: +386 (0)1 200 68 00fax: +386 (0)1 200 68 50
e-mail: [email protected]
Concerning all furnished data, we reserve the right to make alterations to the constructive design, dimensions and technical specifi cations!