Our products – a survey
System diagnosticsFrom infrared thermography to partial discharge measurement
Network planningFrom load flow calculations to reliable calculations for electrical power networks
Maintenance conceptFrom time based to reliability centered maintenance strategies
© C
ompa
ny n
ame
-5
-
Technical executionFrom component replacement to turnkey projects
EngineeringFrom basic principles to detailed network planning
ServiceFrom visual inspections to complete overhauls - availability 24 hours a day
© C
ompa
ny n
ame
-6
-
The products from ABB Calor Emag until now
Circuit breaker
Voltage level kVManufacturing yearType
DC 1952 60 - 380DH 1958 110 - 380DK 1964 110 - 380DL 1969DM 1969 72,5 - 735DY 1969 110 - 380EDF 1986 72,5 - 170EDG - 72,5ELF 1977 72,5 - 765FOL 1968 110FR 1973 145 - 1050FS 1971 72,5 - 525FT 1971 72,5 - 765GD 1 - 12 - 24GD 2 - 12 - 24GK 1 - 12 - 24HA 1 - -HA 2 - -HA 3 - -HB 1970 12 - 24HC 1970 12 - 24
© C
ompa
ny n
ame
-7
-
Voltage level kVManufacturing yearType
HLC 1959 24 - 72,5HLD 1964 145HLR 1969 72,5 - 420HPL 1982 72,5 - 550LOS 1954 10 - 30LOSK 1956 10 - 30LOSR 1956 10 - 30LOSSRM 1958 10 - 30LTB 1990 123 - 170OD 1 1958 10 - 30OD 2 1968 12 - 24OD 3 1970 12 - 24OD 4 1970 12 - 24OD 5 - 12OG 1 1965 10 - 20OG 2 1967 12 - 20OH 2 1969 12 - 24OK 1 1958 10 - 30OK 2 1967 13 - 20OK 3 1970 12 - 36OK 4 1970 12 - 24
© C
ompa
ny n
ame
-8
-
Voltage level kVManufacturing yearType
OK 5 - -OZ 1 1958 10 - 30OZ 2 1960 10 - 30OZ 3 1960 10 - 30SB 1952 10 - 30SC 1952 10 - 30SCA - 12 - 24SCAJ - 12 - 24SD 1952 12 - 36SDA - 12 -SDAJ - 12 -SDJ - 12 - 36SE 1952 12 - 24SEJ - 12 - 24SF 7D - 72,5TR 123/170 1970 123 - 170V 30 nc 25 - -V 30 nc 25I - -VD 1 - 12 - 24VD 2 - 36VD 4 1985 12 - 36VZ 1 - 12 - 24
© C
ompa
ny n
ame
-9
-
High current circuit breaker
Voltage level kVManufacturing yearType
ADG/ADGM 1948 10 - 70DB 1948 10 - 70DR 36 1970 36DRT 24.80 1973 24E 36.150 1970 36HE 1989 24HG 1993 17,5NO 32/33 1652 10 - 30
© C
ompa
ny n
ame
-10
-
Disconector
Voltage level kVManufacturing yearType
AS 1950 10 - 70SBF 1967 52 - 420SDF 1969 72,5 - 420SEF 1974 123 - 245SGF 1974 123 - 420TD 1969 145TF 1957 220 - 380TFB 1970 170 - 765TG 1954 60 - 220TJ 1967 60 - 110TK 1982 525TN 2 - 10 - 30TP 2 - 10 - 30TS - 12 u. 24
© C
ompa
ny n
ame
-11
-
SF6 - gasisolatet switchgear
Voltage level kVManufacturing yearType
CTC - -EBK 1970 145ELK-0 1980 170ENK 1977 72,5ENK 1 - -ENK 2 - 72,5ZF 1 1966 123ZF 2 1966 123ZF 3 1972 123ZF 4 1972 123ZF 7 1977 123ZF 8 1979 72,5ZF 9 1988 123ZL 1 - 12 - 24ZL 4 - 12 - 24ZR 4 - 12 - 24ZV 2 - 7,2 - 52ZV 4 - -ZX 1 - 12 - 24
© C
ompa
ny n
ame
-12
-
Load switchdisconector
Voltage level kVManufacturing yearType
BK 1 - 12 u. 36BK 3 - 12 - 36BK 6 - 24BR 2 - 12 u. 36BR 3 - 12 - 36BR 6 - 24C 4 1996 12 - 24CK 1 1967 10 - 20CK 2 1967 12 - 24CK 3 1977 12 - 24CR 1 1967 10 - 20CR 2 1967 12 - 24CR 3 1977 12 - 24CS 3 1979 12 - 24RL 1977 12 - 24RLD 1979 12 - 24RLDE 1979 12 - 24RLDF 1979 12 - 24RDLFE 1979 12 - 24
© C
ompa
ny n
ame
-13
-
Voltage level kVManufacturing yearType
RLE 1977 12 - 24RLF 1977 12 - 24RLFE 1977 12 - 24RLS 1977 12 - 24RLSE 1977 12 - 24RLSF 1977 12 - 24RLSFE 1977 12 - 24
© C
ompa
ny n
ame
-14
-
Earthing switch
Voltage level kVManufacturing yearType
EK 2 - 10 - 30EK 4 - 12 - 36EK 5 - 12 - 36EK 6 - 7,2 - 24EK 7 - -TE, TEB 1975 72,5 - 525TEC 1975 72,5 - 245
© C
ompa
ny n
ame
-15
-
Medium voltage switch gear
Voltage level kVManufacturing yearType
ZA 1 - 10 - 20ZA 2 - 10 - 20ZG 1 - 10 - 20ZG 2 - 10 - 20ZK 3 - 10 - 20ZK 4 - 10 - 20ZK 7 - 10 - 20ZR 1 - 10 - 20ZR 2 - 10 - 20ZR 4 - 10 - 20
© C
ompa
ny n
ame
-16
-
Metal glated medium voltage switch gear
Voltage level kVManufacturing yearType
ZE - level 30 NZE 3 - 12 - 24ZE 4 - 12 - 24ZE 5 - level10 N and N 20ZE 7 - 12 - 24ZE8 - 12 - 24ZK 8 - 7,2 - 24ZP - 12ZS 1 12 - 24ZS 2 - 24ZS 3 - 36ZS 4 - 12ZS 8 - 12 - 24ZW 4 - level 30 N
© C
ompa
ny n
ame
-17
-
Logistic and Service
Provision with stocks of original spare parts
Spare parts also still in the nextyears (decades) available
Fast dispatch of spare parts
Qualified technical personnel
Provision with stocks of special tools
Original documents to origin supplies of circuit-breakers &switchgears.
© C
ompa
ny n
ame
-18
-
24 hours of call readiness0049 2102 12 12 12
Individual maintenance/service contracts
Customer training courses in the context of maintenance work at site
Repairs locally
Repairs, when desired, also in the workshop Ratingen
© C
ompa
ny n
ame
-19
-
Design department for new solutionsComputer aided engineering enables the detection ofweak points during the design phase
All parts are designed and documented
This ensure a availability of this parts for the next20 years and more
© C
ompa
ny n
ame
-20
-
ABB Laboratories, Ratingen
Type Tests & witness tests
Dielectric Test (BIL)
Power frequency withstand
voltage test
Short time withstand current test
© C
ompa
ny n
ame
-21
-
Panel rebuilding ABB Retrofit-Solution
ZP-Panel for SEC Saudi Arabia
24 kV, 1250 A, 25 kA
ZV2-Panel forDOW Germany
52 kV, 1250 A, 31,5 kA
ZE-Panel for Shell Germany
36 kV, 1250 A, 31,5 kA
© C
ompa
ny n
ame
-22
-
Retrofit for Calor Emag Ratingen
Manufacture:Calor Emag
Switchgear: ZE2
Product: OD1
Ratings Voltage (kV): 12
Current (A): 1250
Fault Rating (kA): 25
Product Name:ZE2-VD4-12-Truck
Components (s):VD4 1212-31
Rating:12 kV1250 A31,5 A
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-23
-
Original Equipment
ABB Retrofit-Solution
Manufacture:Calor Emag
Switchgear: ZE4
Product: OD3
Ratings Voltage (kV): 12
Current (A): 2500
Fault Rating (kA) : ...40
Product Name:ZE4-VD4-4,5 kV -Truck
Components (s):VD4 – 12 kVMWD- Arresters
Rating:4,5 kV2500 A… 40 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
© C
ompa
ny n
ame
-24
-
Manufacture:Calor Emag BBC
Switchgear: ZP BA ,BB
Product: OD3, OD4, GD,HB, VZ, SD, SCA, VAL
Ratings Voltage (kV): 24
Current (A): …1250
Fault Rating (kA) : ...31,5
Product Name:ZE4-VD4--Truck
Components (s):VD4 VM1
Rating:4,5 kV…1250 A… 31,5 kA
Budget Price:On Request
Manufactured by: ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-25
-
Manufacture:Calor Emag
Switchgear: ZE
Product: OD3, OD4, GD, HB,VZ, SD, SCA, VAL
Ratings Voltage (kV): 24
Current (A): …1250
Fault Rating (kA) : ..31,5
Product Name:ZE-VD4-Truck
Components (s):VD4 VM1
Rating:24 kV…1250 A…31,5 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-26
-
Manufacture:Calor Emag BBC
Switchgear: ZE,…, BA, BB
Product: OD3,…,SD…,BA, BB,…
Ratings Voltage (kV):… 12
Current (A): …1250
Fault Rating (kA) : ...31,5
Product Name:ZE4,…,-VD4-12-Truck
Components (s):VD4 VM1
Rating:… 12 kV…1250 A…31,4 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-27
-
Manufacture:Calor Emag BBC
Switchgear: ZE,…, BA, BB
Product: OD3, …, VZ1…
Ratings Voltage (kV): 12
Current (A): 1250
Fault Rating (kA) : 25
Product Name:ZE4, …, -VD4-Truck
Components (s):VD4, VM1
Rating:4,5 kV1250 A25 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-28
-
Manufacture:Calor Emag
Switchgear: ZW4
Product: OD3, VD2, HB, HC
Ratings Voltage (kV):36
Current (A): …2500
Fault Rating (kA) : ...25
Product Name:ZW4-VD4-36-Truck
Components (s):VD4 3612-25
Rating:36 kV1250 A (…2500 A)25 kA (31,5 kA)
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-29
-
Original Equipment
ABB Retrofit-Solution
Product Name:ZE4-VD4-36-Truck
Components (s):VD4
Rating:36 kV…2500 A…31,5 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Manufacture:Calor Emag
Switchgear: ZE… , ZW…
Product: OD3, VD2, HB, HC
Ratings Voltage (kV): 36
Current (A): … 2500
Fault Rating (kA) : ... 25
© C
ompa
ny n
ame
-30
-
Manufacture:Calor Emag
Switchgear: ZP
Product: OD3
Ratings Voltage (kV): 24
Current (A): 1250
Fault Rating (kA) : 20
Product Name:ZP-VD4-24-Truck
Components (s):VD4 2412-20
Rating:24 kV1250 A20 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-31
-
Manufacture:Calor Emag
Switchgear: ZK4
Product: OD1
Ratings Voltage (kV): 36
Current (A): 630
Fault Rating (kA) : 20
Product Name:ZK4-VD4-36 Truck
Components (s): VD4
Rating:36 kV1250 A25 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-32
-
Manufacture:Calor Emag
Switchgear: ZG3
Product: OG-Isocompact
Ratings Voltage (kV): 17,5
Current (A): 630
Fault Rating (kA) : 20
Original Equipment
ABB Retrofit-Solution
Product Name:ZG3-VD4-17-Truck
Components (s):VD4Transformers
Rating:17,5kV630 A20 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
© C
ompa
ny n
ame
-33
-
Manufacture:Calor Emag
Switchgear: ZH5
Product: OD3
Ratings Voltage (kV): 12
Current (A): 630
Fault Rating (kA) : 25
Product Name:ZH5-VD4
Components (s):VD4 VM1Transformers
Rating:12 kV630A (… 2500 A)20 kA (… 31,5 A)
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-34
-
Original Equipment
ABB Retrofit-Solution
Product Name:ZR1-VD4-12-Truck
Components (s):VD4 1206-20
Rating:12 kV630 A20 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Manufacture:Calor Emag
Switchgear: ZR1
Product: OD1
Ratings Voltage (kV): 12
Current (A): 630
Fault Rating (kA) : 20
© C
ompa
ny n
ame
-35
-
Manufacture:Calor Emag
Switchgear: ZS1
Product:
Ratings Voltage (kV): 12
Current (A):
Fault Rating (kA) :
Product Name:Fuses.Withdrawable-Module for ZS1
Components (s):Fuses.Withdrawable-Module
Rating:12 kV
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-36
-
Retrofit for BBC
Original Equipment
ABB Retrofit-Solution
Product Name:BAX-VD4-12-Truck
Components (s):VD4 1212-31MWD- Arresters
Rating:12 kV… 17,5 kV1250 A31,5 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Manufacture:BBC
Switchgear: BAX
Product: RMS-12-CBOD3,… ,SD…,
Ratings Voltage (kV):12
Current (A): 1250
Fault Rating (kA) : 25
© C
ompa
ny n
ame
-37
-
Manufacture:BBC
Switchgear: BA1, BB1
Product: SBKJ-min.-oil-CB
Ratings Voltage (kV):12
Current (A): 1250
Fault Rating (kA) : 31,5
Product Name:BA1-VD4-12-Truck
Components (s):VD4 1212-31
Rating:12 kV1250 A31,5 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-38
-
Manufacture:BBC
Switchgear: BB6
Product: SBKJ-36
Ratings Voltage (kV):36
Current (A): 12501600
Fault Rating (kA) : 2531,5
Product Name:BB6-VD4-Truck
Components (s):VD4 3612-25…31,5VD4 3616-25…31,5
Rating:36 kV1250 A/ 1600 A25 kA / 31,5 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-39
-
Manufacture:BBC
Switchgear: BB5
Product: SBKJ-36
Ratings Voltage (kV):36
Current (A): 1250
Fault Rating (kA) : 25
Product Name:BB5-VD4-36-Truck
Components (s):VD4 3612-25VD4 3616-25
Rating:36 kV1250 A (1600 A)25 kA (31,5 kA)
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-40
-
Manufacture:SACE-MEA
Switchgear Type I
Product: SFA S 24.20.25
Ratings Voltage (kV):24
Current (A): 2000
Fault Rating (kA) : 25
Product Name:MEA-VD4-2420-Truck
Components (s):VD4 2420.25
Rating:24 kV2000A25 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-41
-
Manufacture:BBC
Switchgear:
Product:
Ratings Voltage (kV): 12 k
Current (A): 5400 A
Fault Rating (kA) :
Product Name:ZS1-VD4-(High Current)
Components (s):ZS1 VD4
Rating:12 kV5400 A
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-42
-
Retrofit for VEM
Manufacture:VEM
Switchgear:CSIM 1-10/250
Product:SCI 1-10/630/250
Ratings Voltage (kV):12
Current (A): 630
Fault Rating (kA) : 14,5
Product Name:CSIM-I-VD4-12-Truck
Components (s):VD4 1206-20(SACE-Contactor)
Rating:12 kV630 A20 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-43
-
Manufacture:VEM
Switchgear: CSIM 1-10/350CSIM 1-10/500
Product:
Ratings Voltage (kV):12
Current (A): 1250
Fault Rating (kA) : 25
Product Name:CSIM1-II-VD4-12-Truck
Components (s):VD4 1212-25
Rating:12 kV1250 A25 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-44
-
Manufacture:VEM
Switchgear: CSIM 1-20/630/350
Product:
Ratings Voltage (kV): 24
Current (A): 630
Fault Rating (kA) : 10
Product Name:CSI 1-I-VD4-24-Truck
Components (s):VD4E 2406-16
Rating:24 kV630 A16 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-45
-
Manufacture:VEM
Switchgear:CSIM 1-20/500
Product: SCI 1-20/1250/500
Ratings Voltage (kV): 24
Current (A): 1250
Fault Rating (kA) : 14,5
Product Name:CSIM 1-II-VD4-24-Truck
Components (s):VD4 2412-25
Rating:24 kV1250 A25 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-46
-
Retrofit for other manufactures
Manufacture:GS
Switchgear:
Product:GS
Ratings Voltage (kV): 12
Current (A): 630
Fault Rating (kA) : 31,5
Product Name:GS-VD4-12-Truck
Components (s):VD4 1206-31MWD-Arresters
Rating:12 kV630 A31,5 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-47
-
Manufacture:Ritter
Switchgear:
Product:
Ratings Voltage (kV):
Current (A):
Fault Rating (kA) :
Product Name:
Components (s):
Rating:
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-48
-
Manufacture:Fa. Ritter
Switchgear:
Product: VZ1
Ratings Voltage (kV): 12
Current (A): 630
Fault Rating (kA) : 20
Product Name:
Components (s):VD4 1206-20
Rating:12 kV
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-49
-
Manufacture:Fa in Russia
Switchgear: KPY2
Product:
Ratings Voltage (kV):12
Current (A): 1250
Fault Rating (kA) : 20
Product Name:KPY-VD4-12-Truck
Components (s):VD4 1212-20
Rating:12 kV1250 A20 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-50
-
Manufacture:Magrini
Switchgear: 17 MG 500
Product: OA3-145/36
Ratings Voltage (kV): 17,5
Current (A): 1250
Fault Rating (kA) : 24
Product Name:MG-VD4-12-Truck
Components (s):VD4 1212-25
Rating:12 kV1250 A25 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-51
-
Manufacture:Oerlikon
Switchgear:
Product: MT 24.12 -CB
Ratings Voltage (kV):24
Current (A): 1250
Fault Rating (kA) : 25
Product Name:MT 24.12-VD4-Truck
Components (s):VD4 2412-25
Rating:24 kV1250 A25 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-52
-
Manufacture:VEM
Switchgear: OA
Product: DCI
Ratings Voltage (kV): 24
Current (A): 630
Fault Rating (kA) : 20
Product Name:OA-VD4-24
Components (s):VD4E 2406-20
Rating:24 kV630 A20 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-53
-
Manufacture:Fa. Ritter
Switchgear: RPW-R10
Product: OD3
Ratings Voltage (kV): 12
Current (A): 630
Fault Rating (kA) : 31
Product Name:RPW-VD4-12-Truck
Components (s):VD4 1206.31
Rating:12 kV630 A31,5 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-54
-
Manufacture:Siemens
Switchgear:
Product: H 515
Ratings Voltage (kV):12
Current (A): 630
Fault Rating (kA) : 16
Product Name:H 515-VD4-12-Truck
Components (s):VD4 1206.25
Rating:12 kV630 A25 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-55
-
Manufacture:Siemens
Switchgear: 2 TS 715
Product: H 515
Ratings Voltage (kV): 24
Current (A): 1250
Fault Rating (kA) : 31,5
Product Name:H 515-VD4-24-Truck
Components (s):VD4 2412.31
Rating:24 kV1250 A31,5 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-56
-
Manufacture:Siemens
Switchgear: 8BC1
Product:
Ratings Voltage (kV):24
Current (A): 630
Fault Rating (kA) : 16
Product Name:ZS1-2412.16
Components (s):VD4 2406.16
Rating:24 kV1250 A16 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-57
-
Manufacture:SACE-MEA
Switchgear: Type F
Product: SFA.S 24.12.25
Ratings Voltage (kV):24
Current (A): 1250
Fault Rating (kA) : 25
Product Name:MEA-VD4-2412-Truck
Components (s):VD4 2412.25
Rating:24 kV1250 A25 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-58
-
Manufacture:Westinghouse
Switchgear:
Product: 38 MG
Ratings Voltage (kV):36
Current (A): 1600
Fault Rating (kA) : 25
Product Name:MG-VD4-36-Truck
Components (s):VD4 3616.25
Rating:36 kV1600 A25 kA
Budget Price:On Request
Manufactured by:ABB DEUTD
Original Equipment
ABB Retrofit-Solution
© C
ompa
ny n
ame
-59
-
The solutions
Breaking current
Normal current
kVManufacturPanel / breaker Type
ZA3 (OD1) Calor Emag ... 12 ... 1250 ... 31,5ZE2 (OD1) Calor Emag … 12 … 1250 … 31,5
ZE3, ZE4, ZE7, ZE8ZP1, ZP2
ZW3, ZW4 (OD3/4)ZE4.3, ZW4.3 (OD3/4) Calor Emag ... 12 ... 1250 ... 31,5
ZE5 (OD3/4) Calor Emag ... 12 ... 1250 ... 31,5ZH5 (OD3) Calor Emag … 12 … 1250 … 31,5ZH5 (OD3) Calor Emag … 12 … 2500 … 31,5ZK4 (OD1) Calor Emag ... 12 ... 3150 ... 31,5
Calor Emag ... 12 ... 1250 ... 31,5
© C
ompa
ny n
ame
-60
-
Breaking current
Normal current
kVManufacturPanel / breaker Type
ZK4 (OD1) Calor Emag ... 12 ... 1250 ... 31,5ZK4(OD4) Calor Emag ... 12 ... 1250 ... 31,5
ZK4 Calor Emag ... 12 ... 1600 ... 40ZK4 Calor Emag ... 12 ... 2500 ... 40ZK4 Calor Emag ... 12 ... 3150 ... 40ZK6 Calor Emag ... 12 630 20ZR1 Calor Emag ... 12 ... 1250 ... 31,5
ZR2, ZR3 Calor Emag ... 12 ... 1250 ... 25ZE3, ZE4, ZE7, ZE8
ZP1, ZP2ZW3, ZW4(OD3/4)
Calor Emag ... 17,5 ... 2500 ... 40
© C
ompa
ny n
ame
-61
-
Breaking current
Normal current
kVManufacturPanel / breaker Type
ZE3, ZE4ZP1, ZP2
ZW3, ZW4 (OD3/4)ZE7, ZE8 (OD3/4) Calor Emag ... 17,5 ... 1250 ... 25
ZG3 Calor Emag ... 17,5 ... 1250 20ZE3, ZE4ZP1, ZP2
ZW3, ZW4 (OD3/4)ZE3, ZE4 (OD3/VD2) Calor Emag ... 36 ... 2500 ... 25
ZE8, ZE10.2 (OD3/VD2) Calor Emag ... 36 ... 2500 ... 25ZW3, ZW4 (OD3/VD2) Calor Emag ... 36 ... 2500 ... 25
Calor Emag ... 17,5 ... 1250 ... 25
Calor Emag ... 24 630 ... 25
© C
ompa
ny n
ame
-62
-
Breaking current
Normal current
kVManufacturPanel / breaker Type
ZK3 (OD1) Calor Emag ... 36 ... 1250 ... 25ZK4 (OD1) Calor Emag ... 36 ... 1250 ... 25BA1 (SBJ) BBC … 12 … 1250 … 31,5BB1 (SBJ) BBC … 12 ... 1250 ... 31,5BA1, BA2 BA- and BB-
close toBB1, BB2 (OD3/4) ZE-
switchtrucksBC1 (OD4) BBC 12 630 20
BAX (RM,RG) BBC/Sace … 12 … 1250 … 25
BBC … 12
© C
ompa
ny n
ame
-63
-
Breaking current
Normal current
kVManufacturPanel / breaker Type
BAX (RM,RG) BBC/Sace … 17,5 … 1250 16/BBC in Jemen/
(CB/CC)BA1, BA2 BA- and BB-
close toBB1, BB2 (OD3/4) ZE-
switchtrucksBB5 (SBJ) BBC 36 ... 1600 ... 25BB6 (SBJ) BBC 36 ... 1600 ... 25CSI-10/250 SAD 12 630 … 20CSI1-10/250 SAD 12 630 … 20CSIV-10/250 SAD 12 630 … 20
BBC/CEM … 24 … 1250 … 20
BBC … 24
© C
ompa
ny n
ame
-64
-
Breaking current
Normal current
kVManufacturPanel / breaker Type
CSIV1-10/250 SAD 12 630 … 20BSIG1-10/250 SAD 12 630 … 20CSI 1-10/250 SAD 7,2 SACE VRC
7CSIV 10/250 SAD 7,2 with
contactor CSIV 1-10/250 SAD 7,2BSIG 1-10/250 SAD 7,2
CSIM-12/16 SAD 12 … 800 … 20CSIM1-12/16 SAD 12 … 800 … 20CSIM-12/25 SAD 12 … 1250 … 25
© C
ompa
ny n
ame
-65
-
Breaking current
Normal current
kVManufacturPanel / breaker Type
CSIM1-12/25…31,5 SAD 12 … 1250 … 31,5CSI-10/350…500 SAD 12 … 1250 … 31,5CSI1-10/350…500 SAD 12 … 1250 … 31,5
CSIM1-10/350…500 SAD 12 … 1250 … 31,5CSI1-20/350 SAD 24 630 (1250) 16
CSIM1-20/350 SAD 24 630 (1250) 16BSIG1-20/350 SAD 24 630 16
CSI 20/500 SAD 24 … 1250 … 25CSIM 1-20/500 SAD 24 … 1250 … 25
/Elin/ (MT) Elin/BBC 24 … 1250 … 25/GEN/ (OD4) /Holland/ 12 630 20
© C
ompa
ny n
ame
-66
-
Breaking current
Normal current
kVManufacturPanel / breaker Type
GS (GTC) /GS Korea/ 12 630 31,5„KPУ“ („BMПЭ“) /GUS/ 12 … 1250 … 20/Magrini/ (MG) Magrini 12 … 1250 … 25RPW (OD3) Ritter 12 … 1250 20/Ritter/ (VZ1) Ritter 12 630 20/Ritter/ (GD) Ritter 12 630 31,5/V&H/ (VZ1) V&H 12 630 25/AEG/ (Bf.E) AEG 12 … 2000 50
/Siemens/ (H515) Siemens 12 630 … 31,5/Siemens/ (H515) Siemens 24 1250 25
/Sace Thai./ Sace 24 1250 25
© C
ompa
ny n
ame
-67
-
Breaking current
Normal current
kVManufacturPanel / breaker Type
/Sace Thai./ Sace 24 2000 2538 MG 1500 Westinghouse 36 … 1600 … 25
© C
ompa
ny n
ame
-68
-
Summary
Ratingen City Centre
ABB Utilities RatingenService & Support for
CALOR EMAG Provides:
Improvement of infrastructure
High availablity of electrical energy
Small investment with a fast ROI
Training just for the new devices
in the existing switchgear
Warranty for all replaced parts
Know How, Experience and Quality by the OEM for
CALOR EMAG
Medium Voltage