Seite 1/14
Accessories
Cablesfor Multi-Component Force Sensors, Dynamometers and Force Plates
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 16…
Multi‐Axis Force Sensors
min max
2 1698AD… PFA synthetic braiding 0.2 20 ‐40…120°C IP65 V3 pos. 2x BNC pos. Page 4
1698AA… PFA synthetic braiding 0.2 20 3x BNC pos. Page 2
1698AH… PFA synthetic braiding 2 5 3x SMC neg. Page 6
1698AF… TPC black Ø3.6mm 0.5 20 3x Mini Coax neg. Page 5
1698AE… PFA synthetic braiding 0.2 20 3x KIAG 10‐32 neg. Page 5
1698AK… TPC black Ø3.6mm 0.5 20 IP65 V3 pos. 90° Fischer 9‐pole pos. Page 7
1698AB… TPC black Ø3.6mm 0.5 20 Fischer 9‐pole pos. Page 2
1698AI… PFA, steel braiding 0.3 10 Fischer 9‐pole pos. Page 7
1698AG…1) PFA, steel braiding 2 5 3x Mini Coax neg. Page 6
1698AC…1) PFA, steel braiding 2 5 Fischer 9‐pole pos. Page 4
1698ABW… TPC, Ø3.6mm, Y‐Cable 0.5 20 IP65 2x V3 pos. 90° Fischer 9‐pole pos. Page 3
1698ABB… TPC, Ø3.6mm, Y‐Cable 0.5 20 IP68 2x V3 pos. Fischer 9‐pole pos. Page 3
1693A… 2) PFA 0.1 20 IP65 M8x0,75 3‐pole pos. 3x Mini Coax neg. Page 8
1694A… 2) PFA 0.1 20 IP65 M8x0,75 3‐pole pos. 3x KIAG 10‐32 neg. Page 8
2) outdated connection type, not matching with current Kistler sensors
Dynamometer & Force Plates
min max
sum 3 1697A… PFA, steel braiding 1 5 IP67 7‐pole pos. Page 14
sep 6 1696A… PFA, steel braiding 1 5 IP67 7‐pole pos. Page 14
Z15141sp PFA 1 20 IP40 9‐pole pos. 3x BNC pos. on request
1683Asp PFA with flexible steel hose 2 20 IP65 9‐pole pos. 90° Page 11
1687BQ01… TPC black Ø3.6mm 1 20 IP65 Flange 9‐pole pos. Page 12
1687BQ02… PFA, steel braiding 1 5 IP67 Flange 9‐pole pos. Page 12
1687B… 2 20 IP67 Flange 9‐pole pos. Page 12
1689B… 1 20 IP67 Flange 9‐pole pos. 90° Page 13
Z16620sp PFA 1 20 IP40 9‐pole pos. 8x BNC pos. on request
1685B… TPC black Ø5.6mm 1 20 IP65 9‐pole pos. Page 11
1686A… TPC black Ø5.6mm 1 20 IP65 9‐pole pos. 90° Page 11
1681B… PFA with flexible steel hose 1 20 IP65 9‐pole pos. Page 10
1677AQ01.. TPC black Ø5.6mm 1 20 IP65 Flange 9‐pole pos. Page 9
1677AQ02.. TPC, steel braiding 1 20 IP67 Flange 9‐pole pos. Page 9
1677A… 1 20 IP67 Flange 9‐pole pos. Page 9
1679A… 2 20 IP67 Flange 9‐pole pos. 90° Page 10
Z13705sp… PFA 1 20 IP40 9‐pole neg. 3x BNC pos. on request
1688B… TPC black Ø3.6mm 1 20 IP65 9‐pole neg. Fischer 9‐pole pos. Page 13
Z16634sp.. PFA 1 20 IP40 9‐pole neg. 8x BNC pos. on request
1656Asp PFA 1 20 IP40 9‐pole neg. 8x KIAG 10‐32 neg. Page 13
1678A… TPC black Ø5.6mm 1 25 IP65 9‐pole neg. Fischer 9‐pole pos. Page 10IP65
plugged
‐5…70°CIP65
plugged
Fischer 9‐pole pos.
IP40
IP40
Fischer Connector Dynamometer
Connector Amplifier
IEC/EN60529
IP40
Output Signal
Temp. Range
IEC/EN60529
Cable Cable PropertiesLength [m]
‐40…120°C3
IEC/EN60529
Connector Sensor
Plug
screwed
Connector Amplifier
IP40
welde
d
IP67
IP68
IP65
IP65V3 pos.
IP65
IP65
V3 pos.
V3 pos.
IP40
IP65
IP65
Output Signal
Cable PropertiesLength [m] Temp.
RangeIEC/EN60529
Cable
extension 3
8
IP65
IP65
IP65
IP65
IP65
IP65
IP65
IP40
bolta
ble
plugged
‐5…70°C
‐5…70°C
8
sepa
rate
bolta
ble
plugged
‐5…70°C
PFA with flexible steel hose
Fischer 9‐pole pos.
Fischer 9‐pole pos.sum
IP65
IP65
IP65
IP65
IP65
IP65
old 3 ‐40…120°C screwed IP65
IP40
IP65
IP65
sepa
rate
‐40…120°C6
Plug
screwed
3
PFA with flexible steel hose
1) not suitable with 9306A (Sensor not weldable)
Table of contents
Seite 2/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1698AA… Connecting cable for 3-component sensors with V3 neg. connector (protected design)
Number of conductors 3Length (m) 1/2/5/sp (Lmin = 0,2 m/Lmax = 20 m)Cable 3 x PFA green ø2 mm with synthetic braiding Temperature range –40 … 120 °CUsed for 3-component measurement
123
1 Fx2 Fy3 Fz
Cable plug V3 pos. 3 x BNC pos.Degree of protection IP65 screwed IP40(EN60529) IP67 welded
Type 1698AB… Connecting cable for 3-component sensors with V3 neg. connector (protected design)
Number of conductors 3Length (m) 1/2/5/sp (Lmin = 0,5 m/Lmax = 20 m)Cable TPC black ø3,6 mm Temperature range –40 … 120 °CUsed for 3-component measurement
123
12 Fx34 Fy56 Fz789
Cable plug V3 pos. Fischer 9-pole pos.Degree of protection IP68 screwed IP65(EN60529) (24 hrs @ 13 bar)
123
1 Fx2 Fy3 Fz
Cable diagram
Input Output (Sensor) (Amplifier)
123
12 Fx34 Fy56 Fz789
Cable diagram
Input Output (Sensor) (Amplifier)
Seite 3/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1698ABB... Connecting cable for 6-axis force/moment sensor with V3 neg. connector (protected design)
Number of conductors 6Length (m) sp (Lmin = 0,5 m/Lmax = 20 m)Cable TPC black ø3,6 mm Temperature range –40 … 120 °CUsed for 6-component measurement
Cable plug 2x V3 pos. Fischer 9-pole pos.Degree of protection P68 screwed IP65(EN60529) (24hrs @ 13bar)
Type 1698ABW... Connecting cable for 6-axis force/moment sensor with V3 neg. 90° connector (protected design)
Number of conductors 6Length (m) sp (Lmin = 0,5 m/Lmax = 20 m)Cable TPC black ø3,6 mm Temperature range –40 … 120 °CUsed for 6-component measurement
Cable plug 2x V3 pos. 90° Fischer 9-pole pos.Degree of protection IP67 screwed IP65(EN60529)
Cable diagram
1 2 3 4
YX
Z
32
87654
1
YX
Z
öffentlich
04.07.2019 Kk
100.423.068
1698ABW
für Datenblatt
0
D-00020-X1
Ver.Bl.1 / 1
Material-Nr.
Pinbelegung 2x3pol - 1x8pol1:1
measure. analyze. innovate.
Erstmals verwendet
Erste Proj.-Nr.
Werkstoff
Änderung Datum MassstabErsatz für Kopie Datum
gez.
gepr.
ges.Zeichnungs-Nr.
A4KIWAG-SWX_A4h / Vers. 21-Sep-2017
Das
Urh
eber
rech
t an
dies
er Z
eich
nung
, die
dem
Em
pfän
ger
pers
önlic
h an
vertr
aut w
ird, v
erbl
eibt
uns
erer
Firm
a.O
hne
unse
re s
chrif
tlich
e G
eneh
mig
ung
darf
die
Zeic
hnun
gw
eder
kop
iert
noch
ver
viel
fälti
gt, n
och
an D
rittp
erso
nen
mitg
etei
lt od
er z
ugän
glic
h ge
mac
ht w
erde
n.
Cable diagram
YX
Z
32
87654
1
YX
Z
öffentlich
04.07.2019 Kk
100.423.068
1698ABW
für Datenblatt
0
D-00020-X1
Ver.Bl.1 / 1
Material-Nr.
Pinbelegung 2x3pol - 1x8pol1:1
measure. analyze. innovate.
Erstmals verwendet
Erste Proj.-Nr.
Werkstoff
Änderung Datum MassstabErsatz für Kopie Datum
gez.
gepr.
ges.Zeichnungs-Nr.
A4KIWAG-SWX_A4h / Vers. 21-Sep-2017
Das
Urh
eber
rech
t an
dies
er Z
eich
nung
, die
dem
Em
pfän
ger
pers
önlic
h an
vertr
aut w
ird, v
erbl
eibt
uns
erer
Firm
a.O
hne
unse
re s
chrif
tlich
e G
eneh
mig
ung
darf
die
Zeic
hnun
gw
eder
kop
iert
noch
ver
viel
fälti
gt, n
och
an D
rittp
erso
nen
mitg
etei
lt od
er z
ugän
glic
h ge
mac
ht w
erde
n.
Input Output (Sensor) (Amplifier)
Input Output (Sensor) (Amplifier)
Seite 4/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1698AC... Connecting cable for 3-component sensors with V3 neg. connector (protected design)
Number of conductors 3Length (m) sp (Lmin = 2 m/Lmax = 5 m)*Cable PFA blue ø1 mmCable protection Fluoro-polymer hose, steel braided Temperature range –40 … 120 °CUsed for 3-component measurement
123
12 Fx34 Fy56 Fz789
Cable plug V3 pos., threadless, welded only Fischer 9-pole posDegree of protection IP67 welded IP65(EN60529)
* The protecting hose is torsion proof. To allow a firm Fischer connection you have to order the cable length 0,5 m longer.
123
12 Fx34 Fy56 Fz789
Cable diagram
Input Output (Sensor) (Amplifier)
Type 1698AD... Connecting cable for 2-component sensors with V3 neg. connector (protected design)
Number of conductors 2Length (m) 2/sp (Lmin = 0,2 m/Lmax = 20 m)Cable PFA green ø2 mm with synthetic braiding Temperature range –40 … 120 °CUsed for 2-component measurement
Cable plug V3 pos. 2 x BNC pos.Degree of protection IP65 screwed IP40(EN60529) IP67 welded
Cable diagram
Input Output (Sensor) (Amplifier)
Seite 5/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1698AE... Connecting cable for 3-component sensors with V3 neg. connector (protected design)
Number of conductors 3Length (m) sp (Lmin = 0,2 m/Lmax = 20 m)Cable PFA green ø2 mm with synthetic braiding Temperature range –40 … 120 °CUsed for 3-component measurement
Cable plug V3 pos. 3x KIAG 10-32 pos.Degree of protection IP65 screwed IP65(EN60529) IP67 welded
Type 1698AF... Connecting cable for 3-component sensors with V3 neg. connector (protected design)
Number of conductors 3Length (m) sp (Lmin = 0,5 m/Lmax = 20 m)Cable TPC black ø3,6 mmTemperature range –40 … 120 °CUsed for 3-component measurement
Cable plug V3 pos. 3x Mini Coax neg.Degree of protection IP65 screwed IP40(EN60529) IP67 welded
123
1 Fx2 Fy3 Fz
Cable diagram
Input Output (Sensor) (Amplifier)
123
1 Fx2 Fy3 Fz
Cable diagram
Input Output (Sensor) (Amplifier)
Seite 6/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1698AG... Connecting cable for 3-component sensors with V3 neg. connector (protected design)
Number of conductors 3Length (m) sp (Lmin = 2 m/Lmax = 5 m)Cable PFA blue ø1 mmCable protection Fluoro-polymer hose, steel braided Temperature range –40 … 120 °CUsed for 3-component measurement
Cable plug V3 pos., threadless, welded only 3x Mini Coax neg. 3x Mini Coax neg.Degree of protection IP68 welded IP40(EN60529)
Type 1698AH... Connecting cable for 3-component sensors with V3 neg. connector (protected design)
Number of conductors 3Length (m) sp (Lmin = 2 m/Lmax = 5 m)Cable PFA green ø2 mm synthetic braidingTemperature range –40 … 120 °CUsed for 3-component measurement
Cable plug V3 pos. 3x SMC neg.Degree of protection IP65 screwed IP40(EN60529) IP67 welded
123
1 Fx2 Fy3 Fz
Cable diagram
Input Output (Sensor) (Amplifier)
123
1 Fx2 Fy3 Fz
Cable diagram
Input Output (Sensor) (Amplifier)
Seite 7/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1698AI... Connecting cable for 3-component sensors with V3 neg. connector (protected design)
Number of conductors 3Length (m) sp (Lmin = 0,3 m/Lmax = 10 m)Cable PFA blue ø1 mmCable protection FPM hose, steel braided Temperature range –40 … 120 °CUsed for 3-component measurement
Cable plug V3 pos. 90° Fischer 9-pole pos.Degree of protection IP65 screwed IP65(EN60529) IP67 welded
Type 1698AK... Connecting cable for 3-component sensors with V3 neg. connector (protected design)
Number of conductors 3Length (m) sp (Lmin = 0,5 m/Lmax = 20 m)Cable TPC black ø3,6 mm Temperature range –40 … 120 °CUsed for 3-component measurement
123
12 Fx34 Fy56 Fz789
Cable diagram
Input Output (Sensor) (Amplifier)
123
12 Fx34 Fy56 Fz789
Cable diagram
Input Output (Sensor) (Amplifier)
1 2 3 4
Cable plug V3 pos. Fischer 9-pole pos. 90°Degree of protection IP68 screwed IP65 IP65(EN60529) (24 hrs @ 13 bar)
Seite 8/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1693A… Connecting cable for 3-component sensors with M8x0,75 3-pole neg. connector
Number of conductors 3Length (m) 1/2/5/sp (Lmin = 0,1 m/Lmax = 20 m)Cable TPC black ø3,6 mmTemperature range –40 … 120 °CUsed for 3-component measurement
Cable plug M8x0,75 3-pol. pos. 3 x Mini-Coax neg.Degree of protection IP65 IP40(EN60529)
Type 1694A… Connecting cable for 3-component sensors with M8x0,75 3-pole neg. connector
Number of conductors 3Length (m) 1/2/5/sp (Lmin = 0,1 m/Lmax = 20 m)Cable TPC black ø3,6 mmTemperature range –40 … 120 °CUsed for 3-component measurement
Cable plug M8x0,75 3-pole pos. 3 x KIAG 10-32 pos.Degree of protection IP65 IP65(EN60529)
123
1 Fx2 Fy3 Fz
Cable diagram
Input Output (Sensor) (Amplifier)
123
1 Fx2 Fy3 Fz
Cable diagram
Input Output (Sensor) (Amplifier)
Seite 9/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1677A… Connecting cable for multi-component dynamometer with Fischer flange 9-pole neg. connector
Number of conductors 8Length (m) 5/sp (Lmin = 1 m/Lmax = 20 m)Cable PFA green ø2 mmCable protection Flexible stainless steel hoseTemperature range –5 … 70 °CUsed for 6-component measurement
Cable plug Fischer-Flansch 9-pol. pos. Fischer 9-pole pos.Protection (EN60529) IP67 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Type 1677AQ01sp Connecting cable for multi-component dynamometer Fischer flange 9-pole neg. connector
Number of conductors 8Length (m) sp (Lmin = 1 m/Lmax = 20 m)Cable TPC black ø5,6 mmTemperature range –5 … 70 °CUsed for 6-component measurement
Cable plug Fischer flange 9-pole pos. Fischer 9-pole pos.Protection (EN60529) IP65 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Type 1677AQ02sp Connecting cable for multi-component dynamometer with Fischer flange 9-pole neg. connector
Number of conductors 8Length (m) sp (Lmin = 1 m/Lmax = 20 m)Cable TPC black ø5,6 mmCable protection Fluoro-polymer hose, steel braidedTemperature range –5 … 70 °CUsed for 6-component measurement
Cable plug Fischer flange 9-pole pos. Fischer 9-pole pos.Protection (EN60529) IP67 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Seite 10/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1678A… Extension Cable
Number of conductors 8Length (m) 5/10/25/sp (Lmin = 1 m/Lmax = 25 m)Cable TPC black ø5,6 mmTemperature range –5 … 70 °CUsed for 6-component measurement
Cable plug Fischer 9-pole neg. Fischer 9-pole pos.Protection (EN60529) IP65 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Type 1679A… Connecting cable for multi-component dynamometer with Fischer flange 9-pole neg. connector
Number of conductors 8Length (m) 5/sp (Lmin = 2 m/Lmax = 20 m)Cable PFA green ø2 mmCable protection Flexible stainless steel hoseTemperature range –5 … 70 °CUsed for 6-component measurement
Cable plug Fischer flange 9-pole pos. 90° Fischer 9-pole pos. Protection (EN60529) IP67 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Type 1681B… Connecting cable for multi-component dynamometer with Fischer 9-pole neg. connector
Number of conductors 8Length (m) 1/5/10/20/sp (Lmin = 1 m/Lmax = 20 m)Cable PFA green ø2 mmCable protection Flexible stainless steel hoseTemperature range –5 … 70 °CUsed for 6-component measurement
Cable plug Fischer 9-pole pos. Fischer 9-pole pos.Protection (EN60529) IP65 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Seite 11/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1683A... Connecting cable for multi-component dynamometer with Fischer 9-pole neg. connector
Number of conductors 3Length (m) 5/sp (Lmin = 2 m/Lmax = 20 m)Cable PFA green ø2 mmCable protection Flexible stainless steel hoseTemperature range –5 … 70 °CUsed for 3-component measurement
Cable plug Fischer 9-pole pos. 90° Fischer 9-pole pos.Protection (EN60529) IP65 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Type 1685B… Connecting cable for multi-component dynamometer with Fischer 9-pole neg. connector
Number of conductors 8Length (m) 5/10/sp (Lmin = 1 m/Lmax = 20 m)Cable TPC black ø5,6 mmTemperature range –5 … 70 °CUsed for 6-component measurement
Cable plug Fischer 9-pole pos. Fischer 9-pole pos.Protection (EN60529) IP65 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Type 1686A… Connecting cable for multi-component dynamometer with Fischer 9-pole neg. connector
Number of conductors 8Length (m) 5/10/sp (Lmin = 1 m/Lmax = 20 m)Cable TPC black ø5,6 mmTemperature range –5 … 70 °CUsed for 6-component measurement
Cable plug Fischer 9-pole pos. 90° Fischer 9-pole pos.Protection (EN60529) IP65 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Seite 12/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1687B… Connecting cable for multi-component dynamometer with Fischer flange 9-pole neg. connector
Number of conductors 3Length (m) 5/sp (Lmin = 1 m/Lmax = 20 m)Cable PFA green ø2 mmCable protection Flexible stainless steel hoseTemperature range –5 … 70 °CUsed for 3-component measurement
Cable plug Fischer-Flansch 9-pole pos. Fischer 9-pole pos.Protection (EN60529) IP67 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Type 1687BQ02sp Connecting cable for multi-component cynamometer with Fischer flange 9-pole neg. connector
Number of conductors 3Length (m) sp (Lmin = 1 m/Lmax = 5 m)Cable PFA blue ø1 mmCable protection Fluoro-polymer hose, steel braidingTemperature range –5 … 70 °CUsed for 3-component measurement
Cable plug Fischer-Flansch 9-pole pos. Fischer 9-pole pos.Protection (EN60529) IP67 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Type 1687BQ01sp Connecting cable for multi-component dynamometer with Fischer fange 9-pole neg. connector
Number of conductors 3Length (m) sp (Lmin = 1 m/Lmax = 20 m)Cable TPC black ø3,6 mmTemperature range –5 … 70 °CUsed for 3-component measurement
Cable plug Fischer-Flansch 9-pole pos. Fischer 9-pole pos.Protection (EN60529) IP65 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Seite 13/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1688B Extension Cable
Number of conductors 3Length (m) 5/sp (Lmin = 1 m/Lmax = 20 m)Cable TPC black ø3,6 mmTemperature range –5 … 70 °CUsed for 3-component measurement
Cable plug Fischer 9-pole neg. Fischer 9-pole pos.Protection (EN60529) IP65 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Type 1689B… Connecting cable for multi-component dynamometer with Fischer flange 9-pole neg. connector
Number of conductors 3Length (m) 5/sp (Lmin = 1 m/Lmax = 20 m)Cable PFA green ø2 mmCable protection Flexible stainless steel hoseTemperature range –5 … 70 °CUsed for 3-component measurement
Cable plug Fischer flange 9-pole pos. 90° Fischer 9-pole pos.Protection (EN60529) IP67 IP65
Cable diagram
Input Output (Dynamometer) (Amplifier)
Type 1656Asp Extension cable
Number of conductors 8Length (m) sp (Lmin = 1 m/Lmax = 20 m)Cable 8 x PFA green ø2 mm Temperature range –5 ... 70 °CUsed for 6-component measurement
Cable plug Fischer 9-pole neg. 8x KIAG 10-32 neg.Protection (EN60529) IP40 IP65
Input(Dynamometer)
Output(Amplifier)
Cable diagram
Seite 14/14
Cables – for Multi-Component Force Sensors, Dynamometers and Force Plates, Type 16…
1687
B_00
0-54
5e-0
9.19
© 2007 ... 2019 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, [email protected], www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com.
This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded.
Type 1697A… Connecting cable for multi-component dynamometer with Fischer flange 7-pole neg. connector
Number of conductors 3Length (m) 5/sp (Lmin = 1 m/Lmax = 5 m)Cable PFA blue ø1 mmCable protection Fluoro-polymer hose, steel braidingTemperature range –5 … 70 °CUsed for 3-component measurement
Cable plug Fischer-Flansch 7-pole pos. Fischer 9-pole pos.Degree of protection IP67 IP65(EN60529)
Cable diagram
Input Output (Dynamometer) (Amplifier)
Type 1696A… Connecting cable for multi-component dynamometer with Fischer flange 7-pole neg. connector
Number of conductors 6Length (m) 5/sp (Lmin = 1 m/Lmax = 5 m)Cable PFA blau ø1 mmCable protection Fluoro-polymer hose, steel braidingTemperature range –5 … 70 °CUsed for 6-component measurement
Cable plug Fischer-Flansch 7-pole pos. Fischer 9-pole pos.Degree of protection IP67 IP65(EN60529)
Cable diagram
Input Output (Dynamometer) (Amplifier)