SPECIFICATIONS

B200 & B700 Burners The manufacturer shall provide a burner tested to the current waste oil standard UL 296A and CSA standard B140.4 for burning used oils. The efficiency shall not be less than 80%, and the emissions shall not exceed a number 2 Bacharach spot test, when combined with an INOV8 approved unit heater or boiler and burning listed fuels. The safety system shall be rated for commercial or industrial (as distinguished from residential) with the following features and standard equipment:

CATEGORY SPECIFICATIONS B200 B700 FUEL CONSUMPTION Gallons per hour (GPH) .84 to 3.6 4.6 to 7.2 BTUH Input (x100) 120 to 450 650 to 1.1M TESTED FUELS Grade #2 Oil Yes Yes Used Crankcase Oils Yes Yes Transmission & Hydraulic Oils Yes Yes Crankcase oil with 10% gasoline Yes Yes 90 Weight Gear Box Oil Yes Yes Mineral Spirits Solvent Yes Yes Machine Shop Cutting Oil Yes Yes Vegetable Oils Yes Yes ADDITIONAL FUELS Synthetic oils Yes Yes Commercial & military jet fuels Yes Yes Grades #1, #3,and #4 heating oils Yes Yes INDUSTRIAL SAFETY Fireye Combustion Control Yes Yes CONTROLS Ultra-violet Flame detector Yes Yes 90 Second pre-purge Yes Yes Continual proof of atomizing air Yes Yes Continual proof of combustion air Yes Yes Safe-start sequence Yes Yes Trial for ignition timing (in seconds) 10 10 Flame failure response timing (in seconds) 3 3 Safety Shut-down indicator (visual) Yes Yes Fuel shut-off by electrically operated valve & Mechanically driven needle in oil nozzle Yes Yes Line Voltage thermostat controlling all burner power Yes Yes Aquastat (determined by installer) not supplied not supplied DIMENSIONS (standard) Height: 14" 19" Width: 18" 24" Length: 16" 25" COMPRESSED AIR CFM 2 2 REQUIREMENTS PSIG 30 40 AIR CONNECTION Fitting size to air regulator ¼ NPT ¼ NPT * Not included in burner package

Page 2: Burner Specification Sheet

CATEGORY SPECIFICATION B200 B700

FLAME LENGTH Changes with oil pressure (average) 2.5’ to 5’ 5’ to 7’ FLAME DIAMETER Approximate 12” 18” MOUNTING FLANGE Standard 3 bolt pattern DIAMETER OF AIR TUBE Enters into combustion chamber 4” 5” LENGTH OF AIR TUBE Inside of combustion chamber 1 5/8” 4 ½” CONVENIENCE Additional attempts to establish flame Yes Yes CONTROLS Automatic nozzle clean-out Yes Yes Hour meter Yes Yes Dirty filter indicator Yes Yes Switch to test spark ignition Yes Yes ELECTRICAL Total current draw (in amps) 10 16 Volts 120 120 Required circuit protection (in amps) * 20 20 Frequency - Hz 60 60 Thermostat Voltage ** 120 120 Ignition Transformer, 23 ma secondary, 10,000 V 10,000V continuous duty shielded transformer Intermittent spark ignition (10 seconds) Yes Yes BURNER MOTOR Horsepower 1/5 1/3 RPM 3,450 3,450 FUEL PUMP Suntec Model A2RA Waste Oil Pump Yes Yes OIL NOZZLE Delavan Aspirated Nozzle (#30609) 3.1 to 5 8 to 11 PUMP CONNECTION Fitting size to pump ¼ NPT ¼ NPT EQUIPMENT INCLUDED Vapor elimination from oil Yes Yes Filtration after oil heating Yes Yes Heater switch Standard Standard Line voltage thermostat ** Standard Standard Floating oil pickup assembly Included Included Check valve Included Included Return flow vent system Included Included Installation & Maintenance Manual Included Included OPTIONAL EQUIPMENT Boost pump Draft Inducer (sized per application) SHIPPING WEIGHT Burner packaged separately in box 52 lbs. 72 lbs. WARRANTY One year full warranty on parts (not labor) NOTE * Not included in burner package ** Not applicable to boiler


Top Related