Building Structures [arc 2522]
project 2: extension of a R.C bungalow Structure
chosen existing R.C building:
Kuala Terengganu Mb’s Bungalow
Lecturer :
Group members:
Mr. adib bin ramli
Low Jia Cheng (stanley)
Kelvin ng
Tan Zi Jian
Kelvin chiew kah kheng
Cheah Eugene
Visagan a/l arudselvan
Sean wee yen xhiong
Felicia tiong ying min
0314883
0315081
0318291
0311848
1001GH77034
0313710
0313416
0313610
![Page 2: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/2.jpg)
Table of content:
1. Introduction to case study
2. Architectural drawings
3. Structural drawings
4. Load Distribution Diagrams
5. conclusion
![Page 3: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/3.jpg)
1. Introduction to case study
The case study we chosen is a two storey bungalow, located in Kuala Terengganu. The bungalow is owned by current MB (menteri besar) of Terengganu, Designed by LWC architect.
A pond is place in the middle of the bungalow as the genius loci of the building surrounded by all other space such as living room, dining, bedroom and etc. the pond also act as cooling strategy of the building other than its aesthetic value which enhance the comfort of the users.
we had studied and analyzed architectural plans from the architect and came up with structural plans which indicating the position of columns, beam and slabs.
![Page 4: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/4.jpg)
2.Architectural drawings
Ground Floor Plan Scale 1:200
![Page 5: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/5.jpg)
first Floor Plan Scale 1:200
![Page 6: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/6.jpg)
roof Plan Scale 1:200
![Page 7: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/7.jpg)
3.structural drawings
Foundation layout Plan Scale 1:150
![Page 8: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/8.jpg)
Ground Floor layout Plan Scale 1:150
![Page 9: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/9.jpg)
first Floor layout Plan Scale 1:150
![Page 10: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/10.jpg)
Roof beam layout Plan Scale 1:150
![Page 11: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/11.jpg)
Isometry structural layout Not to scale
Columns Column that doesn’t attach to the ground
Beams that doesn’t attach to the column Beams and slabs
First floor
ground floor
![Page 12: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/12.jpg)
Ground floor load distribution layout Plan Scale 1:150
4.Load distribution diagrams
![Page 13: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/13.jpg)
First floor load distribution layout Plan Scale 1:150
![Page 14: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/14.jpg)
roof beam load distribution layout Plan Scale 1:150
![Page 15: Building Structure Project 2 Group Report](https://reader033.vdocuments.us/reader033/viewer/2022042515/5873b91c1a28abbc788b5001/html5/thumbnails/15.jpg)
5.conclusion
Through this project, we had learnt a lot of the structural design, not only drawing it yet proving with mathematic formula and diagrams. We also explored possibility of different type placement of columns and beams that not only affecting the safety yet aesthetic and comfort for the user experience.
We also learnt how the load are transferred from top to the bottom until the ground, identifying those structural members and understanding how the force is acting on the structural members whether is it capable to withstand ideal amount of load with the space we designed.
we are grateful for the experience and the opportunity to explore the structural members of the building and will apply in our work in future.