BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1
BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBRVersion 1.1DateRevisionDescriptionAuthor
2010-10-14V1.0Completed the initial draft.Zhang Youfang
2009-10-20V1.1Added the configuration contents.Zhang Youfang
1 Summary
1. There is only one monitoring cable between the 2 cabinet. Refer to the Chapter 4.
2. ONLY straight through cable can be used.3. We configure the 3G BTS type the same as the 2G. 2 Overview of BTS3900A Cabinet2.1 Exterior and configurations of the APM30H No.ModuleDescription
1Fan boxThe fan box is configured with the fan, the Hert Power Monitoring Interface unit (HPMI), and the Central Monitoring Unit type A (CMUA), dissipating the heat in the cabinet.
2SLPUThe Signal Lightning Protection Unit (SLPU) is a mandatory component installed in the top 1 U space of the cabinet, providing protection for trunk signals.
3EPS subrackThe EPS subrack provides functions of AC power distribution and DC power distribution for the cabinet.
4BBU3900The BBU3900 processes the baseband signals and enables interaction between the base station and the BSC or RNC.
5PSU (AC/DC)The Power Supply Unit (PSU) converts 110 V AC or 220 V AC power into -48 V DC power.
6PMUThe Power Monitoring Unit (PMU) provides the functions of power system and battery management, power monitoring, and alarm reporting
2.2 Exterior and configurations of the RFC
No.ModuleDescription
1DCDU-01The Direct Current Distribution Unit-01 (DCDU-01) supplies power to each component in the cabinet.
2Fan boxThe fan box is configured with the fan and CMUA. The fan dissipates the heat in the cabinet, and the CMUA provides the functions of the temperature control, Boolean alarm detection, and ELU identification of the cabinet.
3RFUThe Radio Frequency Unit (RFU) performs modulation and demodulation between baseband signals and RF signals, processes data, and combines and divides signals.
2.3 Exterior and configurations of the TMC11H No.ModuleDescription
1Fan boxThe fan box is configured with the fan, HPMI, and CMUA, dissipating the heat in the cabinet.
3DCDU-03The Direct Current Distribution Unit-03 (DCDU-03) supplies power to each component in the TMC11H.
2.4 Exterior and configurations of the IBBS200D No.ModuleDescription
1FanThe fan is installed on the front door of the cabinet, dissipating the heat in the cabinet.
2CMUAThe CMUA provides the functions of the temperature control, Boolean alarm detection, and ELU identification of the cabinet.
3Power distribution boxThe power distribution box is installed on the upper right of the cabinet, transferring the distributing the power to the TEC cooler or fan and to the batteries.
4BatteryThe battery provides long-duration backup power for a base station
2.5 Exterior and configurations of the IBBS200T No.ModuleDescription
1TEC coolerThe TEC cooler is installed in the protecting hood for the TEC cooler on the front door of the cabinet. The TEC cooler consists of the TEC, inner air circulation fan, outer air circulation fan, heat-dissipation piece, and monitoring board
2CMUAThe CMUA provides the functions of the temperature control, Boolean alarm detection, and ELU identification of the cabinet.
3Power distribution boxThe power distribution box is installed on the upper right of the cabinet, transferring the distributing the power to the TEC cooler or fan and to the batteries.
4BatteryThe battery provides long-duration backup power for a base station
3 Monitoring Cable and Port Position
3.1 Monitoring cable
ONLY straight through cable can be used.
The monitoring signal cable connects two CMUAs.
(1) RJ-45 connector
Table 1 Pin assignment for the wires of the FE/GE cable
Pin on the RJ-45 ConnectorWire ColorWire TypePin on the RJ-45 Connector
X1.2OrangeTwisted pairX2.2
X1.1White and orangeX2.1
X1.6GreenTwisted pairX2.6
X1.3White and greenX2.3
X1.4BlueTwisted pairX2.4
X1.5White and blueX2.5
X1.8BrownTwisted pairX2.8
X1.7White and brownX2.7
3.2 APM30HCOM_IN: RS485 signal port connected to the BBU or upper-level CMUA and used to report monitoring informationCOM_485: RS485 signal port communicating with the battery cabinetMON0: No.0 RS485 signal input port
3.3 RFCCOM_IN: RS485 signal port connected to the BBU or upper-level CMUA and used to report monitoring informationCOM_OUT: RS485 signal port connected to the PMU or lower-level CMUA and used to receive monitoring information
3.4 TMC11HCOM_IN: RS485 signal port connected to the BBU or upper-level CMUA and used to report monitoring information
3.5 IBBS200D/IBBS200T
COM_IN: RS485 signal port connected to the BBU or upper-level CMUA and used to report monitoring informationCOM_OUT: RS485 signal port connected to the PMU or lower-level CMUA and used to receive monitoring information
4 Monitoring cable InstallationAll the monitoring cables which are mentioned in this chapter need to be connected on site.4.1 BTS3900A DC 1*TMC11H+1*RFCConnection:
None monitoring cable need to be connected.
Date configuration:
BTS Type:
2G: BTS3900A (DC)
3G: BTS3900A (DC) + RRUCabinet ID (Cabinet Name)Part ID (Part Name)Cabinet IDSubrack IDSlot IDConnected Serial No.Communication Address
No.0 TMC11HTCU008017
RFC0FMU01110014
No.0 TMC11HGATM00500022
4.2 BTS3900A DC 1*TMC11H+2*RFCConnection:
1. COM_OUT(RFC) to COM_IN(Extension RFC)
Date configuration:
BTS Type:
2G: BTS3900A (DC)
3G: BTS3900A (DC) + RRUCabinet ID (Cabinet Name)Part ID (Part Name)Cabinet IDSubrack IDSlot IDConnected Serial No.Communication Address
No.0 TMC11HTCU008017
RFC0FMU01110014
RFC1FMU12110015
No.0 TMC11HGATM00500022
4.3 BTS3900A AC 1*APM30H+1*RFC+1*IBBS200Connection:
1. COM_485(APM30H) -- COM_IN(IBBS) SHAPE \* MERGEFORMAT
Date configuration:
BTS Type:
2G: BTS3900A (AC)
3G: BTS3900A (AC)
Cabinet ID (Cabinet Name)Part ID (Part Name)referenced Cabinet ID (BSC6900)Subrack IDSlot IDConnected Serial Port IDCommunication Address
No.0 APM30PMU007013
No.0 APM30 TCU008017
RFC0FMU01110014
No.0 APM30 BBC0BBC TCU0980123
No.0 APM30GATM00500022
4.4 BTS3900A+DBS3900 AC 2*APM30H+1*RFC+2*IBBS200Connection:
1. MON0(APM30H UEIU) -- COM_IN(Extension APM30H );
2. COM_485(APM30H) -- COM_IN(IBBS200);3. COM_485(Extension APM30H) -- COM_IN(Extension IBBS200);
Date configuration:
BTS Type:
2G: BTS3900A (AC)
3G: BTS3900A (AC) +RRU
Cabinet ID (Cabinet Name)Part ID (Part Name)referenced Cabinet ID (BSC6900)Subrack IDSlot IDConnected Serial Port IDCommunication Address
No.0 APM30PMU007013
No.1 APM30PMU157003
No.0 APM30 TCU008017
No.1 APM30TCU158007
RFC0FMU01110014
No.0 APM30 BBC0BBC TCU0980123
No.1 APM30 BBC0BBC TCU01180023
No.0 APM30GATM00500022
4.5 BTS3900A AC 2*APM30H+2*RFC+2*IBBS200Connection:
1. MON0(APM30H UEIU) -- COM_IN(Extension APM30H );
2. COM_OUT(RFC) -- COM_IN(Extension RFC);3. COM_485(APM30H) -- COM_IN(IBBS200); 4. COM_485(Extension APM30H) -- COM_IN(Extension IBBS200);
Date configuration:
BTS Type:
2G: BTS3900A (AC)
3G: BTS3900A (AC) +RRUCabinet ID (Cabinet Name)Part ID (Part Name)referenced Cabinet ID (BSC6900)Subrack IDSlot IDConnected Serial Port IDCommunication Address
No.0 APM30PMU007013
No.1 APM30PMU157003
No.0 APM30 TCU008017
No.1 APM30TCU158007
RFC0FMU01110014
RFC1FMU12110015
No.0 APM30 BBC0BBC TCU0980123
No.1 APM30 BBC0BBC TCU01180023
No.0 APM30GATM00500022
4.6 DBS3900 AC 1*APM30H+1*IBBS200Connection:
1. COM_485(APM30H) -- COM_IN(IBBS200);
Date configuration:
BTS Type:
3G: DBS3900
Cabinet ID (Cabinet Name)Cabinet ID (BSC6900)referenced Cabinet ID (BSC6900)Subrack IDSlot IDConnected Serial Port IDCommunication Address
No.0 APM30PMU007013
No.0 APM30TCU008017
No.0 APM30 BBC0BBC TCU0980123
4.7 BTS3900A AC 1*APM30H+1*TMC11H+1*RFC+1*IBBS200Connection:
1. COM_OUT(RFC) COM_IN(TMC11H)2. COM_485(APM30H) -- COM_IN(IBBS)
Date configuration:
BTS Type:
2G: BTS3900A (AC)
3G: BTS3900A (AC) +RRUCabinet ID (Cabinet Name)Part ID (Part Name)referenced Cabinet ID (BSC6900)Subrack IDSlot IDConnected Serial Port IDCommunication Address
No.0 APM30PMU007013
No.0 APM30 TCU008017
TMC11HTCU388006
RFC0FMU01110014
No.0 APM30 BBC0BBC TCU0980123
No.0 APM30GATM00500022
5 Default Internal monitoring Cable
All the monitoring cables which are mentioned in this chapter have been connected in the factory. We dont need to connect these cable on site.
If any module in the APM30H has been reallocated, these monitoring cables must be checked.5.1.1 BTS3900A DC1. MON1 (TMC11H UPEU) -- COM_IN(TMC11H)2. MON0 (TMC11H UPEU) -- COM_IN(RFC)
5.1.2 BTS3900A AC1. MON1 (APM30H UPEU) -- COM_IN(APM30H)2. MON0 (APM30H UPEU) -- COM_IN(RFC)3. COM_OUT(APM30H) COM_IN(PMU)
5.1.3 DBS39001. MON1 (APM30H UPEU) -- COM_IN(APM30H)2. COM_OUT(APM30H) COM_IN(PMU)
5.1.4 BTS3900L
1. S1: MON0 (BBU UPEU) -- COM_IN(Lower FMU)2. S3: COM_OUT(Lower FMU) COM_IN(Upper FMU)
5.1.5 GATMThe GATM panel is as below:
Port IDConnectorFunction
ANT0 to ANT5SMA female connectorProviding power and transmitting control signals for the RET antenna
COM1RJ-45 connectorConnecting to the BBU
COM2RJ-45 connectorServing as an extended RS485 port for connecting to other devices
-48 V3V3 power connectorFeeding -48 V DC power
The GATM monitoring cable is connected in the factory.
Outdoor BTS3900A1. MON0 (APM30H UPEU) -- COM1(GATM) 2. COM2(GATM) -- COM_IN(RFC) Indoor BTS3900L1. MON0 (APM30H UPEU) -- COM1(GATM) 2. COM2(GATM) -- COM_IN(FMU0)3. COM_OUT(FMU0) COM_IN(FMU1)
6 Cabinet Configuration
BTS3900A ACBTS3900A Actual Physical ConfigurationParameters to Be Configured During Site Construction
Cabinet ID (Cabinet Name)Part ID (Part Name)referenced Cabinet ID (BSC6900)Subrack IDSlot IDConnected Serial Port IDCommunication Address
No.0 APM30PMU007013
No.1 APM30PMU157003
No.2 APM30PMU267014
No.0 APM30 TCU008017
No.1 APM30TCU158007
No.2 APM30TCU268016
TMC11HTCU388006
RFC0FMU01110014
RFC1FMU12110015
RFC2FMU23110114
RFC3FMU34110115
No.0 APM30 BBC0BBC TCU0980123
No.0 APM30 BBC1BBC TCU11080124
No.1 APM30 BBC0BBC TCU01180023
No.1 APM30 BBC1BBC TCU11280024
No.2 APM30 BBC0BBC TCU01380125
No.2 APM30 BBC1BBC TCU11480126
No.0 APM30GATM00500022
No.0 APM30GATM10510122
BTS3900A DC
BTS3900A DC Actual Physical ConfigurationParameters to Be Configured During Site Construction
Cabinet ID (Cabinet Name)Part ID (Part Name)referenced Cabinet ID (BSC6900)Subrack IDSlot IDConnected Serial Port IDCommunication Address
No.0 TMC11HTCU008017
RFC0FMU01110014
RFC1FMU12110015
No.0 TMC11HGATM00500022
No.0 TMC11HGATM10510122
DBS3900
DBS3900 Actual Physical ConfigurationParameters to Be Configured During Site Construction
Cabinet ID (Cabinet Name)Cabinet ID (BSC6900)referenced Cabinet ID (BSC6900)Subrack IDSlot IDConnected Serial Port IDCommunication Address
No.0 APM30PMU007013
No.1 APM30PMU157003
No.0 APM30TCU008017
No.1 APM30TCU158006
TMC11HTCU288007
No.0 APM30 BBC0BBC TCU0980123
No.0 APM30 BBC1BBC TCU11080124
No.1 APM30 BBC0BBC TCU01180023
No.1 APM30 BBC1BBC TCU11280024
BTS3900L
BTS3900L Actual Physical ConfigurationParameters to Be Configured During Site Construction
Cabinet ID (Cabinet Name)Part ID (Part Name)Cabinet IDSubrack IDSlot IDConnected Serial No.Communication Address
No.0 BTS3900LFMU00110014
No.0 BTS3900LFMU10120015
No.0 BTS3900LGATM00500022
No.0 BTS3900LGATM10510122
(0; 3)
(0; 7)
No.1 APM30 (5)
(1; 3)
(1; 7)
No.0 APM30 (0)
(0; 22)
(1; 23)
IBBS0 (9)
RFC1 (2)
(0; 15)
(0; 14)
RFC0 (1)
IBBS1 (11)
(0; 23)
RFC0 (1)
(0; 14)
IBBS0 (9)
(0; 3)
(0; 7)
(1; 3)
(1; 7)
No.0 APM30 (0)
(0; 22)
(1; 23)
IBBS0 (9)
No.1 APM30 (5)
(1; 3)
(1; 7)
No.0 APM30 (0)
(0; 22)
(1; 23)
IBBS0 (9)
IBBS1 (11)
(0; 23)
IBBS0 (9)
(1; 23)
(0; 22)
No.0 APM30 (0)
(1; 7)
(1; 3)
(1; 7)
No.0 TMC11H (0)
(0; 22)
(0; 14)
RFC0 (1)
(1; 7)
RFC0 (1)
(0; 14)
No.0 TMC11H (0)
(0; 22)
RFC1 (2)
(1; 3)
(1; 7)
(0; 15)
(0; 14)
RFC0 (1)
No.0 APM30 (0)
(0; 22)
(1; 23)
TMC11H (8)
(0; 6)
(0; 14)
RFC0 (1)
PAGE - 15 -