Why Energy Recovery?Cost Benefits
Downsize HVAC equipmentEnergy savingsFavorable paybackRebates
Performance BenefitsHumidity ControlDecouple ventilationPart load performanceCapture exhaust energy
![Page 3: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/3.jpg)
RenewAire CoreConstruction
SymmetricalFully adheredLaminar airflowSingle material
0% cross contamination
Typical velocity 250 – 500 FPM
.6” SP loss typical
Not flammable!
![Page 4: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/4.jpg)
RenewAire Core71% sensible effectiveness
43% - 50% Summer Latent Effectiveness
52% - 59% Winter Latent Effectiveness
53% - 69% Total Effectiveness
![Page 5: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/5.jpg)
Simple, Easy Maintenance Particulate face loading clogs core face
when core is not maintained
However, laminar flow is maintained through core passages
Simple vacuum procedure to core face to clean blockage and change filters
Do not wash core or remove from unit
![Page 6: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/6.jpg)
ERV CertificationsAHRI 1060
EffectivenessPurge airCross-contaminationArbitrary airflow rating points
UL 1812Flammability rating
![Page 7: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/7.jpg)
ERV Selection CriteriaVentilation and Exhaust AirflowsExternal Static Pressure Design ConditionsElectrical Control Strategy
![Page 8: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/8.jpg)
8
EV / BR Series
HE Series
200 to 8000 CFMIndoor & rooftop applicationsNo condensate drainECM & VFDs available
70 to 450 CFMIndoor applicationsNo condensate drainResidential/light-commercial
![Page 9: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/9.jpg)
9
LE Series
CA/PA Series
3,000 to 8,800 CFMIndoor/Rooftop applicationsMultiple cores parallelCost effective for larger airflows
500 to 40,000 CFMApplied SeriesMultiple cores parallelNo blowers/motors
![Page 10: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/10.jpg)
DOAS RD SeriesEnergy recovery and tight humidity control
100% OA requirements
DX / CW & HW
Indoor / Rooftop
Up to 4,400 CFM
![Page 11: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/11.jpg)
11
OAEA
RA
FA (R)
FA (V
)
Airflow Configurations
EA
FA
OA
RA
Indoor Horizontal
Exterior Rooftop
![Page 12: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/12.jpg)
Controls and OptionsControls
Digital time clockMotion (occupancy) controlCarbon Dioxide controlDehumidistatFilter alarms
Standard FeaturesTransformer Relay PackageNon-fused disconnect2” standard MERV-8 filters
OptionsDouble wallFactory installed VFDsOA / FA motorized dampersIndependent blower controlStandard white paintFused disconnect2” MERV-13 filters
![Page 13: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/13.jpg)
ERV ApplicationsNew construction:
Preconditioning OA with ERV allows for downsized HVAC equipment
New ERV technology is more reliable making downsizing more viableOversized HVAC equipment is expensive and inefficientReduce HVAC equipment costIncrease system efficiencyPayback on ERV cost <5 yrsAnnual energy savings
![Page 14: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/14.jpg)
ERV Applications
Retrofits & Renovations: Preconditioning OA with ERV can allow existing HVAC equipment remain unchangedIncreases in outdoor air load without increasing the size of the equipment
![Page 15: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/15.jpg)
ERV Benefits – Part LoadHVAC equipment sized for <1% of year
Ventilation is largest contributorOversized HVAC is inefficient, ineffective and expensiveCan lead to short cycling/humidity issues
ERV can to reduce peak ventilation loadHVAC equipment to better serve the needs INSIDE the space, not the outdoor conditions
![Page 16: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/16.jpg)
ERV Benefits - Exhaust
ASHRAE Standard 62.1-2010, Section 5.16.3.2.5Class 2 air shall not be transferred in to Class 1 spacesException – When using an energy recovery device, recirculation from leakage (EATR), carryover or transfer (Purge air) from the exhaust side of the energy recovery device is permitted
Not to exceed 10%
Use RenewAire’s AHRI 1060 rated static plate core with no recirculation through the core for defrost
0% EATR0% purge air
![Page 17: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/17.jpg)
VRF System with ERVVRF fan coil units have strict EAT ranges
Bringing in too much untreated outside air may cause the mixed EAT to be outside the acceptable range
Using a zoned or central ERV can bring EAT to an acceptable temperature without needing a full DOAS system!
Typical Heating EAT Range
59°F DB 81°F DB
Typical Cooling EAT Range
59°F WB 75°F WB
![Page 18: Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015](https://reader035.vdocuments.us/reader035/viewer/2022062421/56649d745503460f94a549fb/html5/thumbnails/18.jpg)
OA 300 CFM5F DB
RA 700 CFM70F DB
MA 1000 CFM50.8F DB
Without ERV: Unacceptable EAT
With ERV: Acceptable EAT
OA 300 CFM51.2F DB
RA 700 CFM70F DB
MA 1000 CFM
64.4F DB
VRF System with ERVTypical Heating EAT Range