SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGA
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\AUSTLEDC01\Projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0001.dwg Mar 19, 2015 - 4:25PM mcr55964
Riverstone East PrecinctInfrastructure Master Plan Existing Site Plan
JT .
ADS .
GC .
GL .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0001
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
Riverstone East precinct boundary
Surrounding precinct boundary
Existing cadastre
LGA boundary
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
P7 19.03.2015 MMc GL CJAIssued for Exhibition
SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGA
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
W
W
375m
m
450mm
750mm
750mm
750mm
Water trunkpipeline (2015)
Water trunkpipeline (2022)
Water trunkpipeline (2015)
Water trunkpipeline (2022)
Water trunkpipeline (2015)
Water trunkpipeline (2015)
Existing water reservoirWS0476
Water trunkpipeline (2022)
Existing Boxhill WaterStation WP0187K03
Water trunkpipeline (2040)
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\austledc01\projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0020.dwg Mar 19, 2015 - 4:29PM mcr55964
Riverstone East PrecinctInfrastructure Master Plan Water Servicing Strategy Plan
JT .
ADS .
GC .
GL .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0020
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
Riverstone East precinct boundary
Surrounding precinct boundary
Existing cadastre
LGA boundary
Existing water reservoir
W
Existing water main
North West Rail Stabling yard and station
Trunk water main (2015)
W Trunk water main (2022)
W Trunk water main (2040)
• Dependent on market demand.
Existing water structure
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
Proposed Stage 1 boundary
Proposed Stage 2 boundary
P7 19.03.2015 MMc GL CJAIssued for Exhibition
E
E
E
E
E
SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGA
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\AUSTLEDC01\Projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0010.dwg Mar 19, 2015 - 4:27PM mcr55964
Riverstone East PrecinctInfrastructure Master Plan Combined Services Plan
JT .
ADS .
GC .
GL .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0010
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
Riverstone East precinct boundary
Surrounding precinct boundary
Existing cadastre
Existing water reservoir
Existing water main
Existing sewer
Existing Transgrid transmission line easement
Existing Endeavour Energy easement
Existing electricity
Existing Transgrid transmission line - 330 kv
Existing electricity Overhead
Existing Transmission Pylon
Existing zone substation
Existing trunk gas main(Jemena Gas West pipeline)
Existing Telecomunications Exchange
Existing Telecommunication line
Existing Telecommunication Overhead
Existing Optic Fibre
Existing Optic Fibre and copper cables
LGA boundary
Environmental conservation / open space
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
P7 19.03.2015 MMc GL CJAIssued for Exhibition
SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGA
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
375m
m
450mm
750mm
750mm
750mm
Drinking water trunkpipeline (2015)
Drinking water trunkpipeline (2015)
Indicative feeder toservice EAP
Drinking water trunkpipeline (2015)
Drinking water trunkpipeline by 2022
Drinking water trunkpipeline by 2015
Boxhill WP0187K03Water Station
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\austledc01\projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0021.dwg Mar 19, 2015 - 4:30PM mcr55964
Riverstone East PrecinctInfrastructure Master PlanWater Servicing Strategy PlanStage 1Early Activation Precinct
JT .
ADS .
GC .
GL .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0021
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
Riverstone East precinct boundary
Surrounding precinct boundary
Existing cadastre
Existing water main
Existing water reservoir
W Trunk water main (2015)
W Indicative Water feeder for EAP
LGA boundary
North West Rail Stabling yard and station
Early Activation Precinct
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
Proposed Stage 1 boundary (EAP)
Proposed Stage 2 boundary
P7 19.03.2015 MMc GL CJAIssued for Exhibition
SRM
SRM
SRM
150mm
225mm
375mm
300mm
300mm
225mm
300mm
225mm
225mm
300m
m
300mm
20
30
30
40
20
30
30
40
30
30
30
40
40
40
3040
50 50
50
50
40
50
60
50
40
40
3040
30 40 50
50 40
40 5050
60 50 50 60 60
40
50
60 60 50
50
4050
40
3020
20
40
5030
40
50
30
40 50
60
50
50
60
50
50
First Ponds Creek Carrier (2015)
Box Hill Carrier Section 2 (2015)
First Ponds Creek Carrier (2015)
Chains of Ponds Creek Carrier Section 3
Chains of Ponds CreekCarrier Section 4
SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGA
Existing Second Ponds Creek Carrier
Indicative feeder has capacityfor approximately 900additional equivalent persons,to service stabling yard
C14
C1
C2
C3
C4
C6
C7
C8
C9
C10
C11
C12
C13
Feeder alignment providedby Sydney Water
Indicative feeder has capacityfor approximately 400additional equivalent persons.
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\austledc01\projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0030.dwg Mar 19, 2015 - 4:33PM mcr55964
Riverstone East PrecinctInfrastructure Master Plan Sewer Servicing Strategy Plan
JT .
ADS .
GC .
GL .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0030
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
Riverstone East precinct boundary
50
C1
CatchmentApproximate
Developable Land(ha)
Anticipated Land Use ApproximateLot Yield
EquivalentPersons (EP)
ApproximateFeeder Size (mm)
C1 15.66Low Density Resiential;Regional Open Space 225 788 225
C2 26.91 Low Density Resiential 385 1348 225
C3 10.28 Low Density Resiential 147 515 150
C4 78.64 Low Density Resiential 1124 3934 375
C5 48.99 Low Density Resiential 700 2450 300
C6 44.48 Low Density Resiential 636 2226 300
C7 34.49 Low Density Resiential 300 1051 225
C8 55.22Low Density Resiential; High
Density Residnetial"450 Low250 High" 1825 300
C9 4.56 Industrial - 684 225
C10 8.22 Industrial - 1233 225
C11 53.59Low Density Resiential;Regional Open Space 766 2681 300
C12 36.46Low Density Resiential;Regional Open Space 521 1824 300
C13 0.00 Regional Open Space 0 0 -
Total 5339* 19979*
The following has been assumed in undertaking the assessment- Assumed 14.3 low density residential lots per hectare of gross developable area. This allows for roads, parks, etc.; and- High density residential has been assessed as 70 equivalent persons per gross hectare.
• Feeders shown are indicative only. Actual size and location may vary whendetailed design has been undertaken.
• * Approximate lot yield only based on possible development land. Actual yieldmay vary.
Surrounding precinct boundary
Existing cadastre
Existing sewer
Proposed sewer pipeline (2015)
Existing contour
North West Rail Stabling yard and station
Proposed sewer pipeline (dependant on market)
Sewer catchments
Sewer catchment nodes
Indicative sewer feeders
External precinct draining through site.
LGA boundary
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
Proposed Stage 1 boundary
Proposed Stage 2 boundary
P7 19.03.2015 MMc GL CJAIssued for Exhibition
20
3040
30
40
20
30
30
40
30
30
30
40
40
40
3040
50 50
50
50
40
50
60
50
40
40
3040
30 40 50
50 40
40 5050
60 50 50 60 60
70
40
50
60 60 50
50
4050
40
3020
20
40
5030
40
50
30
40 50
60
50
50
60
50
50
SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGA
SRM
SRM
SRM
225mm
300mm
C7
C8
First Ponds Creek Carrier (2015)
First Ponds Creek Carrier (2015)Indicative Ø225mmfeeder to service EAP
Indicative Ø300mmfeeder to service EAP
Feeder sizing based on developablearea of approximately 35ha [Low densityresidential], comprising approximately300 lots (450m² lot size)
Feeder sizing based on developable area ofapproximately 50ha, comprising approximately450 low density residential lots (450m² lot size)and 250 high density residential units(approximate GFA of 3.5ha)
Indicative feeder size hascapacity for approximately 900additional equivalent persons
Existing Second Ponds Creek Carrier
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\austledc01\projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0031.dwg Mar 19, 2015 - 4:35PM mcr55964
Riverstone East PrecinctInfrastructure Master Plan Sewer Servicing Strategy PlanEarly Activation Precinct
JT .
ADS .
GC .
DB .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0031
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
50
C1
• Feeders shown are indicative only. Actual size and location may vary whendetailed design has been undertaken.
• * Approximate lot yield only based on possible development land. Actual yieldmay vary.
Riverstone East precinct boundary
Surrounding precinct boundary
Existing cadastre
Existing sewer
Proposed sewer pipeline (2015)
Existing contour
Proposed sewer feeders for EAP
Sewer catchments
Sewer catchment nodes
External precinct draining through site.Excluded from assessment
LGA boundary
North West Rail Stabling yard and station
Early Activation Precinct
CatchmentApproximate
Developable Land(ha)
Anticipated Land Use ApproximateLot Yield
EquivalentPersons (EP)
ApproximateFeeder Size (mm)
C7 34.49 Low Density Resiential 300 1051 225
C8 55.22Low Density Resiential; High
Density Residnetial"450 Low250 High" 1825 300
Total 1000* 2876*
The following has been assumed in undertaking the assessment- Assumed 14.3 low density residential lots per hectare of gross developable area. This allows for roads, parks, etc.;- Area around stabling yard has been assumed to be zoned as industrial with 150 equivalent persons per gross hectare; and- High density residential has been assessed as 70 equivalent persons per gross hectare.
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
Proposed Stage 1 boundary
Proposed Stage 2 boundary
P7 19.03.2015 MMc GL CJAIssued for Exhibition
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGA
2x Possible 132kV Transmissionlines with 10m wide easementwithin adjacent property
Existing 132kV Transmission line.Easement width 30m
Existing 132kVTransmission line
Existing 132kVTransmission line
Existing 33kVTransmission line
Possible Riverstone East ZoneSubstation - 45MVA (90MVA)
Existing Schofields ZoneSubstation - 45MVA
Existing Riverstone ZoneSubstation - 33kV 25MVA
Existing Rouse HillSwitching Station.
Existing MungeriePark ZS - 90MVA
Existing 330kV Transgrid Transmissionline. Easement width 60.96m
Existing 330kV Transgrid Transmissionline. Easement width 85m
To Vineyard Bulk SupplyPoint (BSP)
To Hawkesbury TS
To South Marsden ParkZone Substation (45MVA)
Existing 132kV Transmissionline. Easement width 30m
To proposed North Box HillZone Substation (45MVA)
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\austledc01\projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0040.dwg Mar 19, 2015 - 4:36PM mcr55964
Riverstone East PrecinctInfrastructure Master Plan Electricity Strategy Plan
JT .
ADS .
GC .
GL .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0040
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
Riverstone East precinct boundary
Surrounding precinct boundary
Existing Transmission Pylon
Possible zone substation
Existing zone substation
E Possible electricity
Existing Transgrid transmission line easement
Existing Endeavour Energy easement
Existing electricity
Existing Transgrid transmission line - 330 kv
Existing electricity Overhead
Existing cadastre
North West Rail Stabling yard and station
LGA boundary
Possible electricity easement
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
Proposed Stage 1 boundary
Proposed Stage 2 boundary
P7 19.03.2015 MMc GL CJAIssued for Exhibition
SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGA
PE
PEPE
PEPE
PEPE
PEPE
E
E
E
E
E
PE
PE
PEPE
PE
New overhead 11kvfeeders on existingoverhead infrastructure
Existing 132kV Transmission line.Easement width 30m
Existing 132kVTransmission line
Existing 132kVTransmission line
Existing 33kVTransmission line
Existing Schofields ZoneSubstation - 45MVA
Existing Riverstone ZoneSubstation - 33kV 25MVA
Existing Rouse HillSwitching Station
Existing MungeriePark ZS - 90MVA
Existing 330kV Transgrid Transmissionline. Easement width 60.96m
Existing 330kV Transgrid Transmissionline. Easement width 85m
To Vineyard Bulk SupplyPoint (BSP)
To Hawkesbury TS
To South Marsden ParkZone Substation (45MVA)
Existing 132kV Transmissionline. Easement width 30m
Two feeders to be broughtfrom existing Schofields ZoneSubstation to supply EAP
Current network capacity foradditional 700-1400 lots
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\austledc01\projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0041.dwg Mar 19, 2015 - 4:37PM mcr55964
Riverstone East PrecinctInfrastructure Master Plan Electricity Servicing Strategy PlanEarly Activation Precinct
JT .
ADS .
GC .
GL .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0041
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
Riverstone East precinct boundary
Surrounding precinct boundary
Existing Transmission Pylon
Existing zone substation
Existing Transgrid transmission line easement
Existing electricity
Existing Transgrid transmission line - 330 kv
Existing electricity Overhead
Existing cadastre
Existing Endeavour Energy easement
PE Indicative electrical feeders for EAP
LGA boundary
North West Rail Stabling yard and station
Early Activation Precinct
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
Proposed Stage 1 boundary
Proposed Stage 2 boundary
P7 19.03.2015 MMc GL CJAIssued for Exhibition
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G GG
G
G
G
G
G
G
G
SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGA
150mm steel feeder main.Construction dependenton market expansion
200mm steel feeder mainprojected for 2017
200mm steel feeder mainprojected for 2025
existing 200mm steel main
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\austledc01\projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0050.dwg Mar 19, 2015 - 4:40PM mcr55964
Riverstone East PrecinctInfrastructure Master Plan Gas Servicing Strategy Plan
JT .
ADS .
GC .
GL .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0050
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
Existing trunk gas main
G Proposed gas main
Riverstone East precinct boundary
Surrounding precinct boundary
Existing cadastre
North West Rail Stabling yard and station
LGA boundary
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
Proposed Stage 1 boundary
Proposed Stage 2 boundary
P7 19.03.2015 MMc GL CJAIssued for Exhibition
SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGA
Existing 200mm steel main
Early activation precinctto gain supply fromexisting infrastructure
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\austledc01\projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0051.dwg Mar 19, 2015 - 4:40PM mcr55964
Riverstone East PrecinctInfrastructure Master Plan Gas Servicing Strategy PlanEarly Activation Precinct
JT .
GL .
GC .
DB .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0051
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
Riverstone East precinct boundary
Surrounding precinct boundary
Existing cadastre
Existing trunk gas main(Jemena Gas West pipeline)
LGA boundary
North West Rail Stabling yard and station
Early Activation Precinct
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
Proposed Stage 1 boundary
Proposed Stage 2 boundary
P7 19.03.2015 MMc GL CJAIssued for Exhibition
Riverstone Exchange
Kellyville Exchange Area
Kellyville Exchange locatedon Old Windsor Road
SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGARiverstone Exchange Area
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\austledc01\projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0060.dwg Mar 19, 2015 - 4:38PM mcr55964
Riverstone East PrecinctInfrastructure Master Plan Telecom Servicing Strategy Plan
JT .
ADS .
GC .
GL .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0060
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
Riverstone East precinct boundary
Surrounding precinct boundary
Existing cadastre
Existing Telecomunications Exchange
North West Rail Stabling yard and station
Existing Telecommunication line
Existing Telecommunication Exchange Boundary
Existing Telecommunication Overhead
Existing Optic Fibre
Existing Optic Fibre and copper cables
LGA boundary
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
Proposed Stage 1 boundary
Proposed Stage 2 boundary
P7 19.03.2015 MMc GL CJAIssued for Exhibition
SchofieldsRoad
Guntawong
Road
Garfield
Road
East
Clarke
Street
Windsor
Road
Windsor
Road
Tallawong
Road
Cudgegong
Road
Worcester
Road
Riverstone
Road
Cranbourne
Street
Boundary
Road
Riverstone EastPrecinct
RiverstonePrecinct
BoxhillPrecinct
Alex AvenuePrecinct
BoxhillIndustrialPrecinct
Area 20Precinct
Baulkham Hills LGA
Blacktown LGA
Riverstone Exchange
Kellyville Exchange Area
Riverstone Exchange Area
Key to symbols
App’dCh’k’dDescriptionDrawnDateRev
RevStatus
Drawing Number
Scale at A1
Eng check
Approved
Coordination
Dwg check
Drawn
Designed
Title
Notes
Client
Reference drawings
TFW
\\austledc01\projects\parramatta\Projects\33xxxx\334311\06 CAD\6_4 working drawings\Civil\Autocad\1_is_riverstoneeast\Drawings\MMD-334311-C-DR-RE-XX-0061.dwg Mar 19, 2015 - 4:31PM mcr55964
Riverstone East PrecinctInfrastructure Master Plan Telecom Servicing Stategy PlanEarly Activation Precinct
JT .
ADS .
GC .
GL .
CJA .
CJA .
1:10000 PRE
MMD-334311-C-DR-RE-XX-0061
P7
Level 3, 90 Phillip StreetParramatta, NSW 2150AustraliaPO Box 163, ParramattaNSW 2124, Australia
+61 (0)2 9891 5044+61 (0)2 9891 5386www.mottmac.com.au
© Mott MacDonald Australia Pty Limited. ACN 134 120 358This document is issued for the party which commissioned it and for specific purposes connected with the captioned project only. It should not be relied upon by any other party or used for any other purpose.We accept no responsibility for the consequences of this document being relied upon by any other party, or being used for any other purpose, or containing any error or omission which is due to an error or omission in data supplied to us by other parties.
Issued For Exhibition@
0 100100 20050 300
Scale 1:10000PLAN A1
Riverstone East precinct boundary
Surrounding precinct boundary
Existing cadastre
Existing Telecomunications Exchange
Existing Telecommunication line
Existing Telecommunication Exchange Boundary
Existing Telecommunication Overhead
Existing Optic Fibre
Existing Optic Fibre and copper cables
LGA boundary
North West Rail Stabling yard and station
Early Activation Precinct
P3 03.09.2014 ADS GL CJAIssued for Information
P4 28.11.2014 ADS GL CJAIssued for Draft ILP
P5 16.01.2015 AMP GL CJAIssued for Exhibition
P6 27.01.2015 AMP GL CJAIssued for Exhibition
Prposed Stage 1 boundary
Proposed Stage 2 boundary
P7 19.03.2015 MMc GL CJAIssued for Exhibition