Biogas Production from
Al-Rustumiya Sewage Plants as A source to
Renewable EnergyDr. Riyadh S. Almukhtar
Anaerobic Digestion (AD)
Anaerobic Digestion (AD) is the consequence of series metabolic interactions among various groups of microorganisms. It occurs in three stages:-
Hydrolysis, AcidogenesisMethanogenesis.
Anaerobic Digestion (AD)
Anaerobic Digestion (AD)Energy equivalents 1 Watt = 1 joule second-11 Wh = 1 x 3600 joules (J)1 kWh = 3600000 J1 kWh = 3.6 MJ22 MJ (1m3 biogas) = 22/3.6 kWh= 6.1 kWhElectrical conversion efficiency = 35%Therefore 1m3 biogas = 2.14 kWh (elec.)
Anaerobic Digestion (AD)
Before Biogas is Used Removal of Contaminants Moisture and particulates in all recovery
processes• Inefficient combustion, blocked nozzles• Reduced by condensers, filters Hydrogen sulfide in most recovery
processes• In presence of moisture, forms sulfuric
acid, which causes corrosion
Municipal Waste Water Treatment
The sludge that produced in municipal wastewater treatment plants seems to be problems in some countries while in other countries it recognized as a source of power and they utilized it in environmental friends rather than harming the environment
Municipal Waste WaterTreatment Stages
1. primary sedimentation. Solid-water suspension is partially separated in conical tanks
2. Secondary Treatment (biological )The dissolved solids and fine particles that don’t settle in primary sedimentation are treated by aerobic bacteria. These microorganisms using the oxygen for oxidation of solid particles and convert them to perceptible solids in aeration tank.
Municipal Waste Water Treatment Stages
The solids that produced in last step (sludge + aerobic bacteria) are deposited secondary sedimentation.
Some of activated sludge returned to aeration tank and the waste is mixed with primary sludge then fed to thickener basins.
The aim of thickening is decreasing of sludge volume up to 30% by dewatering.
Primary sludge Primary is also called raw sludge which comes
from the bottom of the primary clarifier. Primary sludge is easily biodegradable since it consists of more easily digestible carbohydrates and fats, compared to activated sludge which consists of complex carbohydrates, proteins and long chain hydrocarbons (Gray et al., 2007). So biogas is more easily produced from primary sludge.
Activated sludge Activated sludge is also called excess
sludge or waste activated sludge which comes from the secondary treatment. It‘s a result of overproduction of microorganisms in the activated sludge process. The content of activated sludge was just mentioned above. Activated sludge is more difficult to digest than primary sludge.
Municipal Waste WaterTreatment Stages
Al-Rustumiya plant
Al-Rustumiya plant is one of the biggest sewage treatment plants in Iraq. It is divided to North and South plant. It had been established different time, the first plant called Zero established in 1962 and since then many additional plants had been added through seventh and eighteenth of last century.
Al-Rustumiya plant
Al-Rustumiya plant (both North and South) is dealing with about 650,000 (m3 /day) of wastewater and serve round about 3,000,000 persons.
Unfortunately Al-Rustamiyah plant doesn’t use anaerobic digestion for produced sludge where the sludge go directly to drying beds to dry and then it sold as a fertilizer
0 2 4 6 8 10 12 14 16
Time, day
0
100
200
300
400
500
600
Acc
umila
ted
biog
as p
rodu
ctio
n (m
l)
Pre-treatment of sludge
Chemical: For alkaline pre-treatment 3liters of sludge sample filled the three beakers (1 liter capacity) and pH values of samples were set at 9, 10 and 11 respectively, by addition of 10N sodium hydroxide (NaOH). The beakers were mechanically stirred at 250(rpm) for 2(hr). After alkaline pre-treatment, the hydrochloric acid (HCl) solution of 10N was added to set the pH at optimum level (pH of 7).
Pre-treatment of sludge
0 2 4 6 8 10 12 14 16
Time, day
-200
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200A
ccum
ilate
d bi
ogas
pro
duct
ion
(ml)
chemical pH=9 chemical pH=10 chemical pH=11
Figure: Accumulated biogas after chemical pre-treating.
Thermal: The low temperature pre-treatment was carried out at 60◦C and 80◦C. 1liter of sludge was heated by magnetic stirrer-heater for 60 min and the beaker was covered with plastic film (to avoid water evaporation) and gently stirred (10 rpm) to ensure temperature homogeneity. After 60 min heating period, this sludge cooled to ambient temperature
Pre-treatment of sludge
.
Click icon to add picture
0 2 4 6 8 10 12 14 16
Time, (day)
0
200
400
600
800
1000
Acc
umila
ted
biog
as p
rodu
ctio
n (m
l)
60 o C 80 o C
Thermo-Chemical: The sludge sample was chemically pre-treated by addition of (NaOH) to set the pH (11) and then thermally heated up to 80 as a selected optimum thermal temperature. This sample then cooled to ambient temperature and buffered by addition of (HCl) to normal pH (7).
Pre-treatment of sludge
.
.
0 2 4 6 8 10 12 14 16
Time, (day)
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
Acc
umila
ted
biog
as p
rodu
ctio
n (m
l)
Figure : Accumulated biogas after different pre-treatment process..
0
500
1000
1500
2000
2500
3000
3500
Acc
umul
ated
Bio
gas P
rodu
ctio
n, m
l
Control Thermal T=80 oC Ultrasonic 30 kHz Chemical pH=11 Thermo-Chemical
Pre-treatment of sludgeAccording to figure higher biogas volume was
achieved by 30 KHz pre-treating frequency which was (3209ml) after 14 days of digestion in the next, thermo-chemical pre-treating pH
(11) +80 accumulate a (2298ml) volume of biogas followed by chemical pre-treating pH
(11) which was (2028ml) and finally 80 thermally pre-treated sludge resulted in
(949ml) of total biogas production
Pre-treatment of sludgewhile the lower volume of biogas was
recorded for control (blank test) digestion which was (509ml). The percentage increasing of biogas by 30 KHz was (530.45%), pH (11) +80 (351.47%), pH (11) (298.43%) and 80 (86.45%) comparing to
control digestion (blank test).
Conclusions -:Arrangement of improvement efficiencies of on
biogas productionUltrasonic 30 KHz > Thermo-chemical pH (11)
+ 80 > Chemical pH (11) > Ultrasonic 50 KHz > Chemical pH (10) > Thermal 80 > Thermal 60 > Chemical pH (9) > Control (blank test)
Conclusions -: Anaerobic digestion was very appropriate
to Iraqi warm weather to reduce as much as possible of daily accumulated sludge in Al-Rustumiya WWTP in addition to decreasing of emitted bad odors and to generate electricity to overcome the shortage
Al-Rustumiya plantWe believe that it is important to use A D
units in Al-Rustumiya plant for many reasons 1. Power generation from biogas produced
can cover the plant capacity requirements ( less dependency on national generation system)
2. Sludge without A D still had different types of pathogens which effects on farmer live or vegetable consumers
For employees and neighborhoods health because active organic matter can attract disease carrying vectors such flies beside the bad odors
energy recovery from sewage sludge decrease the need of fossil oil and decrease the environmental impact of global warming
THE END