RVM/UA-2 Module ATEXFlow Monitor
Operation instructions
Flow monitor for usein explosion-hazard zones
Series RVM/UA-2Type RVM/UA-2/02 thru RVM/UA-2/30with switch contactSG-15EX*********** Read this manual prior to performing any task!
RVM/UA-2 Modul ATEX, 2, en_US
© Meister Strömungstechnik GmbH 2019
Meister Strömungstechnik GmbH
Im Gewerbegebiet 2
63831 Wiesen
Germany
Telephone: +49 6096 9720 - 0
Fax: +49 6096 9720 - 30
E-mail: [email protected]
Internet: www.meister-flow.com
Diese Anleitung wurde erstellt von:
Meister Strömungstechnik GmbH
Technische Änderungen vorbehalten
04.05.2020RVM/UA-2 Module ATEX Flow Monitor2
These instructions facilitate the safeand efficient handling of a flow monitor(referred to as "device" in the fol-lowing). The instructions are an inte-gral part of the device and must bekept within easy reach for the per-sonnel in the immediate vicinity of thedevice at all times. Personnel mustcarefully read and understand theseinstructions before commencing allwork. The basic requirement for safework is adherence to all safety andhandling instructions stipulated inthese instructions. The local accident-prevention regulations and generalsafety standards and regulations forthe field of application of the devicealso apply. Illustrations in theseinstructions are provided to aid generalunderstanding and might deviate fromthe actual model. No claims can bederived from any such differences.
Limitations of liability
All details and instructions in thismanual have been compiled underconsideration of the valid standardsand regulations, the current state-of-technology and our many years ofknowledge and experience. The manu-facturer does not accept any liabilityarising from:
n non-observance of any details inthese instructions
n improper use of the device, or usethat is not in accordance withthese instructions
n use of non-trained personnel
n unauthorized retrofitting or tech-nical changes that have not beenauthorized by the manufacturer
n use of non-approved replacementparts
The duties and obligations agreedupon in the delivery contract apply infull, as well as the general terms andconditions, the terms of delivery by themanufacturer and the valid legal regu-lations applicable at the conclusion ofthe contract.
Copyright
These operating instructions are pro-tected by copyright.
Except for internal purposes, transferof these instructions to third-parties,copying them in any way– even in part – as well as dissemina-tion and/or communication of their con-tent is forbidden without prior writtenauthorization from Meister Strömung-stechnik ("manufacturer"). Violationsare subject to claims for indemnifica-tion. The manufacturer reserves theright to assert additional claims.
Copyright is the property of the manu-facturer.
© Meister Strömungstechnik GmbH
Im Gewerbegebiet 2
63831 Wiesen
Germany
Supplemental directives
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 3
Table of contents1 Overview..................................................................................................... 6
1.1 Short description.................................................................................. 61.2 Warranty and guarantee provisions..................................................... 61.3 Customer service................................................................................. 6
2 Safety.......................................................................................................... 72.1 Explanation of symbols........................................................................ 72.2 Correct use in explosion-hazard zones............................................... 82.3 Special precautions for use in explosion-hazard zones.................... 102.3.1 Precautions for use in explosion-hazard zones.............................. 112.4 Personnel requirements.................................................................... 122.5 Personal safety equipment................................................................ 132.6 Protective systems............................................................................ 13
3 Areas of employment............................................................................... 143.1 Mechanical component (flow meter without limiting contacts and
electrical accessories)....................................................................... 143.1.1 Exterior of the device...................................................................... 143.1.2 Interior of the device....................................................................... 143.1.3 General safety information for the mechanical component of the
device............................................................................................. 153.1.4 Categorization of the mechanical component of the flow monitor.. 163.1.5 List of media................................................................................... 183.1.6 Applicable documents.................................................................... 203.2 Electrical component of the device (limiting contacts)....................... 233.2.1 Applicable documents.................................................................... 23
4 Operating data.......................................................................................... 324.1 Operating data for the mechanical component of the device............ 324.2 Switch contact operating data........................................................... 324.3 Labeling of the switch contacts.......................................................... 34
5 Transport, packaging and storage......................................................... 35
6 Installation and initial startup................................................................. 366.1 Safety................................................................................................ 36
Table of contents
04.05.2020RVM/UA-2 Module ATEX Flow Monitor4
6.2 Tools.................................................................................................. 366.3 Protection of the flow monitor............................................................ 366.4 Electrical connection.......................................................................... 366.5 Grounding the device........................................................................ 366.6 Contact protection measures............................................................. 36
7 Operation.................................................................................................. 38
8 Troubleshooting....................................................................................... 39
9 Maintenance............................................................................................. 409.1 Return Materials................................................................................ 409.1.1 Return Materials Authorization....................................................... 40
10 Disassembly and disposal...................................................................... 41
11 Technical data.......................................................................................... 4211.1 Dimension sheet.............................................................................. 4211.2 General specifications...................................................................... 4311.3 Replacement parts........................................................................... 45
12 Annex........................................................................................................ 48
13 Index.......................................................................................................... 49
Table of contents
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 5
1 Overview1.1 Short description
Fig. 1: RVM/UA-2 flow monitor
1 Switch point adjustment scale2 Explosion-proof switch contact
SG-15EX***********3 Mechanical display with indicator
scale and pointer
The flow monitor RVM/UA-1 monitorsthe continuous flow of liquids. It isdesigned for installation into pipe sys-tems.
A float inside the device is moved bythe medium flowing through it. Thedesired switch point can be set on theswitch point adjustment scale,whereby the arrow on the switch con-tact is aligned to the desired volumeflow value on the adjustment scale.
Electrical monitoring is accomplishedby explosion-proof limit switch contactSG-15EX***********. The electrical con-nection is via the cast on power cableor various other connectors.
1.2 Warranty and guar-antee provisions
Warranty and guarantee provisions arecontained in the general terms andconditions of the manufacturer.
1.3 Customer serviceFor technical information, please con-tact our customer service department(for contact details, see Page 2).
Furthermore, our staff is always inter-ested in receiving new information andexperiences gained from application ofthe device, which might be useful inimproving our products.
Overview
Customer service
04.05.2020RVM/UA-2 Module ATEX Flow Monitor6
2 SafetyThis Chapter provides an overview ofimportant safety aspects required foroptimum protection of personnel aswell as for safe installation and safeoperation of the device.
Non-observance of the handling andsafety instructions listed in this manualmay result in hazardous/dangerous sit-uations and in damage to property.
2.1 Explanation of sym-bols
Safety instructions
Safety instructions in this manual aremarked by symbols. The safetyinstructions are preceded by signalwords that indicate the level of danger/hazard.
To prevent accidents or injuries to per-sons as well as damage to property,always observe the safety instructionsand proceed carefully.
DANGER!
This combination of symbol andsignal word indicates an imme-diate, dangerous situation thatresults in death or serious injuryif it is not avoided.
WARNING!
This combination of symbol andsignal word indicates a possiblydangerous situation that mightresult in death or serious inju-ries if it is not avoided.
Safety
Explanation of symbols
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 7
CAUTION!
This combination of symbol andsignal word indicates a possiblydangerous situation that mightresult in minor or slight injuriesif it is not avoided.
NOTICE!
This combination of symbol andsignal word indicates a possiblydangerous situation that mightresult in damage to propertyand to the environment if it isnot avoided.
Tips and recommendations
This symbol emphasizes usefultips and recommendations aswell as information for efficientand failure-free operation.
Signs used in these instructions
The following symbols and highlightingare used in these instructions to iden-tify handling instructions, the descrip-tion of results, lists/enumerations, ref-erences and other elements:
Designates step-by-step han-dling instructions.
ð Designates a state or anautomatic sequence as aresult of a specific operatingstep.
n Designates randomly ordered enu-merations and list entries
Ä “Signs used in these instructions”on page 8, designates references tochapters in these instructions.
2.2 Correct use inexplosion-hazardzones
The device is designed and con-structed exclusively for the correct usein accordance with these instructions.
The flow monitor serves exclusively formonitoring the continuous flow of liq-uids.
The areas of application are specifiedin Chapter 3 of these instructions.
The admissible operating conditionsare specified in Chapter 4 of theseinstructions.
Safety
Correct use in explosion-hazard zones
04.05.2020RVM/UA-2 Module ATEX Flow Monitor8
Correct use of the device includes theobservance of all specifications in theOperating Instructions for "RVM/UA-2Module BASICS" and "RVM/UA-2Module ATEX".
Any addition or different application,above and beyond the correct use inaccordance with these instructions, isdeemed as incorrect use.
WARNING!
Danger due to incorrect use!– Use the flow monitor only
within the stipulated per-formance limits
– Do not subject the flowmonitor to severe tempera-ture fluctuations
– Do not use the flow monitorwith quick-acting valves
– Do not use the flow monitorwith solenoid valves
– Do not subject the flowmonitor to vibrations
– Do not subject the flowmonitor to pressure surges
– Do not use the flow monitorwith media containingsolids or abrasives
– Only use the flow monitorwith media previouslyapproved by the manufac-turer
– Do not use the flow monitoras the sole monitoringdevice to prevent dan-gerous conditions
– Do not install the flow mon-itor as a load bearing partwithin a pipeline system
– The flow monitor must beinstalled so, as to precludedamage by outside force. Ifnecessary, install an appro-priate impact protectiondevice
Safety
Correct use in explosion-hazard zones
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 9
– The flow monitor may onlybe installed in explosion-hazard zones if:– the labeling on the flow
monitor,– the labeling on the
switch unit installed onthe flow monitor,
– and the informationcontained in theaccompanying docu-mentation (OperatingInstructions "RVM/UA-2 Module BASICS"and Operating Instruc-tions "RVM/UA-2Module ATEX"),authorize such installa-tion and operation.
– Planning and design ofequipment, protective sys-tems and components isthe responsibility of thefacility operator
– The potential impact, incase of an explosion, mustbe taken into account bythe facility operator.
– The facility operator isresponsible for the substi-tution, or the reduction ofthe quantity of substances,which may cause an explo-sive atmosphere
All claims for damages due to incorrectuse are excluded.
Incorrect use of the flow monitor mayresult in dangerous conditions.
2.3 Special precautionsfor use in explosion-hazard zones
The following chapter lists residualrisks that might arise from the device.
To reduce health risks and preventdangerous conditions, observe thesafety instructions listed here, thesafety instructions listed in other chap-ters of these Operating Instructions, aswell as all safety instructions listed inthe Operating Instructions for "RVM/UA-2 Module BASICS".
These Operating Instructionscannot cover all conceivabledangers because many dan-gers arise, not from the deviceitself, but from the respectivemedia flowing through it.Always observe the instructionson the appropriate safety datasheets when using hazardousmedia!
Safety
Special precautions for use in explosion-hazard zones
04.05.2020RVM/UA-2 Module ATEX Flow Monitor10
2.3.1 Precautions for usein explosion-hazardzones
DANGER!
Danger to life from explo-sions– Potentially explosive dust-
air mixtures and hybrid mix-tures are not permittedinside the flow meter/flowmonitor and must beexcluded by the operator!
– Dust accumulations are notpermitted, neither insidethe flow meter/flow monitor,nor on the outside surfaceand must be excluded bythe operator! Whencleaning, do not use drycloths!
– To avoid electrostaticcharges capable ofresulting in dangerous sit-uations, the followingrequirements must be met:– All conductive parts,
capable of electrostaticcharging, must be con-nected and grounded.
– Dangerous electro-static charging of non-conductive parts andmaterials, includingsolids, fluids and dust,must be avoided.
– Ignitable dischargesmust be excluded.
– Chemical reactions, pyrol-ysis or biological processesinside the flow meter/flowmonitor are not permittedand must be excluded bythe operator.
– Intrusion of foreign mate-rials which can generatesparks, is not permitted andmust be excluded by theoperator.
– Friction, which may causelocal heat build-up andsparking, is not permittedand must be excluded bythe operator!
– Impact processes, involvingmaterials such as rust orlight alloys (e.g. aluminumor magnesium) are not per-mitted and must beexcluded by the operator.
– High voltage and currentsthat may cause sparkingare not permitted and mustbe excluded by the oper-ator.
– Electromagnetic waves in afrequency range between104 to 3×1012 Hz, as maybe found in the vicinity ofradio broadcasting stationsor high-frequency genera-tors, are not permitted andmust be excluded by theoperator.
Safety
Special precautions for use in explosion-hazard zones > Precautions for use in explosion-hazard zones
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 11
– Electromagnetic waves in afrequency range between3×1011 to 3×1015 Hz, whichcan occur as radiation fromprotective systems or com-ponents (e.g. lamps, arclamps, lasers), are not per-mitted and must beexcluded by the operator.
– Devices that can focusradiation, and that can pro-vide an ignition source forparticles and surfaces, arenot permitted and must beexcluded by the operator.
– Ionizing radiation, thatexceeds the minimum igni-tion temperature of the sur-rounding combustibleatmosphere, is not per-mitted and must beexcluded by the operator.
– Ultrasound sources, thatcan ignite the sonicatedmaterial, are not permittedand must be excluded bythe operator.
– Adiabatic compression andshock waves are not per-mitted and must beexcluded by the operator.
– Exothermic reactions,including auto-ignition ofdust, is not permitted andmust be excluded by theoperator.
2.4 Personnel require-ments
WARNING!
Risk of injury due to insuffi-ciently trained and qualifiedpersonnel!If unqualified personnel work onthe device or are located withinits hazard zone, dangers arisewhich may result in serious inju-ries and considerable damageto property.
– All work must be performedby qualified personnel only
– Keep unqualified personnelaway from hazard zones.
The personnel requirements, as formu-lated in the Operating Instructions for"RVM/UA-2 Module BASICS" Chapter2.4, are valid. For employment withinexplosion-hazard zones, only trainedand qualified personnel may be used.Responsibility for the choice of per-sonnel and their qualification rests withthe facility operator. The requirementsfor standards DIN EN 60079-14 andDIN EN 60079-17 must be taken intoconsideration.
Refer also to the Operating Instruc-tions "RVM/UA-2 Module BASICS",Chapter 2.9 "Responsibility of theowner".
Authorized personnel is to berestricted to those persons who can beexpected to carry out their work reli-ably. Persons whose ability to respondis influenced, e.g. by drugs, alcohol ormedication, are not authorized.
Safety
Personnel requirements
04.05.2020RVM/UA-2 Module ATEX Flow Monitor12
Observe the age and occupational reg-ulations at the site when choosing per-sonnel.
2.5 Personal safetyequipment
Personal safety equipment is used toprotect personnel from hazards/dangers that might impair their safetyor health during work.
When performing the various tasks at,and with the device, personnel mustwear personal safety equipment. Spe-cial reference to this equipment ismade in the Operating Instructions for"RVM/UA-2 Module BASICS". Thefacility operator must ensure that theprotective clothing used in explosion-hazard zone is suitable and approved.
2.6 Protective systemsThe design of the safety features isdescribed in the Operating Instructions"RVM/UA-2 Module BASICS". Theoperator must ensure that all appli-cable regulations which apply to oper-ation in an explosion-hazard zone aremet.
Safety
Protective systems
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 13
3 Areas of employment3.1 Mechanical compo-
nent (flow meterwithout limiting con-tacts and electricalaccessories)
3.1.1 Exterior of thedevice
n Devices of the RVM/UA-1 typemay be employed in areas inwhich an explosive atmosphere,composed of a gas/air- or dust/air-mixture, may occasionally occur.The exterior of the device maytherefore be suitably located inexplosion hazard zone 1, zone 2,zone 21, or zone 22
n Dust accumulations are not per-mitted; neither internally, nor onthe outside surface of the flowmeter/flow monitor and must beexcluded by the operator.
3.1.2 Interior of the devicen Inside the device, only those flow
media may be used, to which thefollowing applies:
n the media is listed on the medialist (Chapter 3.1.5) and
n the medium is not aggressive tothe wetted parts of the device, and
n the device is approved b the man-ufacturer for use with the medium.
n It is permissible to occasionallyhave an explosive gas/air mixtureinside the device (explosionhazard zone 1). At no time maygasses of explosion hazard groupIIC (e.g. hydrogen or acetylene)be present inside device.
n Explosive dust-air mixtures andhybrid mixtures are not permittedinside the flow meter/flow monitorand must be excluded by the oper-ator.
n Chemical reactions, pyrolysis orbiological processes inside theflow meter/flow monitor are notpermitted and must be excludedby the operator.
n The entry of foreign materials thatmay produce sparks is not per-mitted and must be excluded b theoperator.
Areas of employment
Mechanical component (flow meter without limiting contacts and electrical accessories) > Interior of the device
04.05.2020RVM/UA-2 Module ATEX Flow Monitor14
3.1.3 General safety infor-mation for themechanical compo-nent of the device
n Dust accumulation are not per-mitted; neither internally, nor onthe outside surface of the flowmeter/flow monitor and must beexcluded by the operator. Whencleaning, do not use dry cloths!
n In case of hazard through staticelectricity, the following require-ments must be met:– All conductive parts capable
of charging themselves elec-trostatically must be con-nected and grounded.
– Dangerous electrostaticcharging of non-conductiveparts and materials, includingsolids, fluids and dust, mustbe avoided.
– Ignitable discharges must beexcluded
n Friction, which may cause localheat build-up and sparking, is notpermitted and must be excludedby the operator.
n Impact processes involving mate-rials such as rust or light alloys(e.g. aluminum or magnesium) arenot permitted and must beexcluded by the operator.
n High voltage and currents thatmay cause sparking are not per-mitted and must be excluded bythe operator.
n Electromagnetic waves in a fre-quency range between 104 to3×1012 Hz, as may be found in thevicinity of radio broadcasting sta-tions, or high-frequency genera-tors, are not permitted and mustbe excluded by the operator.
n Electromagnetic waves in a fre-quency range between 3×1011 to3×1015 Hz, which can occur asradiation from protective systemsor components (e.g. lamps, arclamps, lasers), are not permittedand must be excluded by the oper-ator.
n Devices which can focus radiation,and which can provide an ignitionsource for particles and surfaces,are not permitted and must beexcluded by the operator.
n Ionizing radiation, which exceedsthe minimum ignition temperatureof the surrounding combustibleatmosphere, is not permitted andmust be excluded b the operator.
n Ultrasound sources, which canignite the sonicated material, arenot permitted and must beexcluded by the operator.
n Adiabatic compression and shockwaves are not permitted and mustbe excluded by the operator.
Areas of employment
Mechanical component (flow meter without limiting contacts and electrical accessories) > General safety information for the mechanical component
of the device
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 15
n Exothermic reactions, includingauto-ignition of dust, are not per-mitted and must be excluded bythe operator.
n The device must be installed insuch a way as to precludedamage by outside force. It is theresponsibility of the operator toinstall appropriate protectivedevices.
3.1.4 Categorization ofthe mechanical com-ponent of the flowmonitor
n Equipment groupinternal: IIexternal: II
n Equipment categoryinternal: 2external: 2
n Atmosphereinternal: Gas (G)external: Gas (G), Dust (D)
n Type of protection: h (Construc-tional Safety "c")
n Gas groupinternal: IIBexternal: IIC, IIIC
n Temperature classificationinternal: T5, T6external: T5, T6external: T100 °C, T80 °COperating temperatures for devicewithout limit switch contactsThe maximum media tempera-ture for a device without limitswitch contacts must be lessthan:– the ignition temperature of the
medium and– the ignition temperature of the
atmosphere surrounding thedevice and
– less than or equal to 100 °C
It is the responsibility of the oper-ator to ensure that these require-ments are met concurrently.
Areas of employment
Mechanical component (flow meter without limiting contacts and electrical accessories) > Categorization of the mechanical component of the flow
monitor
04.05.2020RVM/UA-2 Module ATEX Flow Monitor16
The minimum media tempera-ture for a device without limitswitch contacts must be higherthan or equal to - 20 °C.It must be ensured that themedium does not freeze.The maximum ambient tempera-ture for a device without limitswitch contacts must be lessthan:– the ignition temperature of the
medium and– the ignition temperature of the
atmosphere surrounding thedevice
– and less than or equal to100 °C
It is the responsibility of the oper-ator to ensure that these require-ments are met concurrentlyThe minimum ambient tempera-ture for a device without limitswitch contacts must be higherthan or equal to - 20 °C.Operating temperatures for adevice with the following limitswitch contacts:Explosion proof switch contacts,Series SG-15EX*********** withdesign examination:EPS 13 ATEX 1 596 UThe maximum media tempera-ture for a device with these limitswitch contacts must be lessthan:– the ignition temperature of the
medium and– the ignition temperature of the
atmosphere surrounding thedevice and
– less than 45 °C
It is the responsibility of the oper-ator to ensure that these require-ments are met concurrentlyThe minimum media tempera-ture for a device with these limitswitch contacts must be higherthan - 5 °C .It must be ensured that themedium does not freeze.The maximum ambient tempera-ture for a device with these limitswitch contacts must be lessthan:– the ignition temperature of the
medium and– the ignition temperature of the
atmosphere surrounding thedevice and
– less than 45 °C
It is the responsibility of the oper-ator to ensure that these require-ments are met concurrentlyThe minimum ambient tempera-ture for a device with these limitswitch contacts must be higherthan - 5 °C.
n EPL (Equipment Protection Level):Gb (Gas), Db (Dust)
n Labeling of the mechanical com-ponent of the flow meter/monitor:internal: II 2G Ex h IIB T5, T6Gbexternal: II 2G Ex h IIC T5, T6Gbexternal: II 2D Ex h IIIC T100°C, T80 °C Db
Areas of employment
Mechanical component (flow meter without limiting contacts and electrical accessories) > Categorization of the mechanical component of the flow
monitor
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 17
3.1.5 List of mediaMedia used Ignition temp. Explosion limit
[%]
Lower Upper
Argon Inert gas
Cargon gaseous mixtureArgon+CO2
CO2 Inert gas
CO2liquid
Diesel 255 (ASTME659-78) 0,6 6,5
Biodiesel SME Soya seed oilmethyl ester
285 (ASTME659-78)
Biodiesel RME Rape seed oilmethyl ester
283 (ASTME659-78)
EDC (1,2-Dichlorethane) 440 6,2 16
Natural gas 575 - 640 4 17
Ethanol 400 3,1
City gas 560
Gaseous mix-ture 90 %Argon + 10 %CO2
Gaseous mix-ture 96 %Argon + 4 %O2
Helium none none none
Air
Methane 595 4,4 16,5
Areas of employment
Mechanical component (flow meter without limiting contacts and electrical accessories) > List of media
04.05.2020RVM/UA-2 Module ATEX Flow Monitor18
Media used Ignition temp. Explosion limit[%]
Lower Upper
Methanol 455 6,1 44
N2 none none none
N2O none none none
NaOH Natrium-hydroxide-NaOH ("causticsoda")
none none none
NaOH 50% none none none
Caustic sodaNaOH 25%
none none none
NH3 anhydrousammonia
630 15 28
n-Heptan(highly puri-fied)
215 1 6,7
O2 none none none
Oil
organic Saltsolution den-sity 1,35 kg/l20 °C
Peroxide none none none
RAF2 Raffinate 2 385 1,6 10
Spirits ofAmmonia(25%)
630 15 28
SO2 Sulphur dioxide none none none
Areas of employment
Mechanical component (flow meter without limiting contacts and electrical accessories) > List of media
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 19
Media used Ignition temp. Explosion limit[%]
Lower Upper
Solvana 2000(Universalcleaningagent)
236 0,4 7
Petroleumether
>200 0,6 7
Water none none none
Water / Nitrite-solution
Hydrogenper-oxyde 50%(ultra pure)
none none none
Hydrogenper-oxyde 50weight.-%, dis-solved inWater
none none none
Propane 470 2,2 9,5
n-Butane 365 1,4 8,5
3.1.6 Applicable docu-ments
Areas of employment
Mechanical component (flow meter without limiting contacts and electrical accessories) > Applicable documents
04.05.2020RVM/UA-2 Module ATEX Flow Monitor20
Areas of employment
Mechanical component (flow meter without limiting contacts and electrical accessories) > Applicable documents
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 21
.
Areas of employment
Mechanical component (flow meter without limiting contacts and electrical accessories) > Applicable documents
04.05.2020RVM/UA-2 Module ATEX Flow Monitor22
3.2 Electrical compo-nent of the device(limiting contacts)
The electrical limit switch contacts,Series SG-15EX*********** , were sub-jected to design examination: EPS 13ATEX 1 596 U
This component type and acceptablevariations thereto is specified in thesupplement to this certificate.
The electrical limiting contacts mayonly be employed in combination withRVM/UA-2 type devices in areas inwhich an explosive atmosphere, com-posed of a gas/air- or dust/air- mixture,may occasionally occur. The limitingcontacts of the device may thereforebe suitably located in explosion hazardzone 1, zone 2, zone 21, or zone 22.Dust accumulations are not permittedon the limiting contacts and must beexcluded by the operator.
3.2.1 Applicable docu-ments
The electrical limit switch contactswere subjected to a design examina-tion
EPS 13 ATEX 1 596 U
The following documents must beobserved:
Manufacturer's declaration for theemployment of explosion-proof switchunits within a safety concept
n Design examination certificate withattachment
n Conformity declaration (MeisterStrömungstechnik GmbH)
n IECEX CoC+ ExTrIECEX EPS 13.0026U
Areas of employment
Electrical component of the device (limiting contacts) > Applicable documents
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 23
.
Areas of employment
Electrical component of the device (limiting contacts) > Applicable documents
04.05.2020RVM/UA-2 Module ATEX Flow Monitor24
.
Areas of employment
Electrical component of the device (limiting contacts) > Applicable documents
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 25
.
Areas of employment
Electrical component of the device (limiting contacts) > Applicable documents
04.05.2020RVM/UA-2 Module ATEX Flow Monitor26
.
Areas of employment
Electrical component of the device (limiting contacts) > Applicable documents
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 27
.
Areas of employment
Electrical component of the device (limiting contacts) > Applicable documents
04.05.2020RVM/UA-2 Module ATEX Flow Monitor28
.
Areas of employment
Electrical component of the device (limiting contacts) > Applicable documents
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 29
.
Areas of employment
Electrical component of the device (limiting contacts) > Applicable documents
04.05.2020RVM/UA-2 Module ATEX Flow Monitor30
.
Areas of employment
Electrical component of the device (limiting contacts) > Applicable documents
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 31
4 Operating dataOperating data for employment inexplosion-hazard zones.
4.1 Operating data forthe mechanicalcomponent of thedevice
The maximum operating pressure isspecified in Chapter 10.7 of the Oper-ating Instructions for "RVM/UA-2Module BASICS".
The maximum media and ambienttemperatures for the mechanical com-ponent depends on various factors. Itis the responsibility of the operator tospecify the maximum temperatureswithin the framework set by the guide-lines in Chapter Ä Chapter 3.1.4 “Cat-egorization of the mechanical compo-nent of the flow monitor” on page 16and ensure adherence thereto.
4.2 Switch contactoperating data
Operating data for the explosion-proofswitch units, series SG-15EX***********with design examination.
Certificate number: EPS 13 ATEX 1596 U
This component and any acceptablevariation thereto are specified in theschedule to this certificate and thedocuments therein referred to.
The sign "U" placed behind the certifi-cate number indicates that this certifi-cate should not be confounded withcertificates issued for equipment orprotective systems. This componentcertificate only serves as a basis forthe issuing of certificates for equip-ment or protective systems.
Installation of the switch contact is setin the type certificate for the respectiveelectrical equipment
The operating temperature limits of- 5 °C< TService <+ 45 °C must not beexceeded.
The following intrinsically safe limitvalues must not be exceeded, noteven for brief periods:
Table 1: Electrical data - Gas
Ui li Pi
< 12,1 V 1,0 A 3,0 W
< 20 V 0,309 A 1,55 W
< 25 V 0,158 A 0,99 W
< 30 V 0,101 A 0,76 W
Li = 0
Ci = 0
Operating data
Switch contact operating data
04.05.2020RVM/UA-2 Module ATEX Flow Monitor32
Table 2: Electrical data - Dust
Ui li Pi
< 12,1 V 0,250 A 0,75 W
< 20 V 0,250 A 0,75 W
< 25 V 0,250 A 0,75 W
< 30 V 0,250 A 0,75 W
Li = 0
Ci = 0
Operating data
Switch contact operating data
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 33
4.3 Labeling of the switch contactsThe labeling of the components must contain the following information:
II 2G Ex ib IIC
II 2D Ex ib IIIC
Examples of the switch contact labels:
Fig. 2: Switch contact with connector DIN 43650 (Form C)
Fig. 3: Switch contact with cable
Operating data
Labeling of the switch contacts
04.05.2020RVM/UA-2 Module ATEX Flow Monitor34
5 Transport, packaging and storageTransport, packaging and storage innon-explosion-hazard zones aredescribed in Chapter 4, "RVM/UA-2Module BASICS".
In explosion-hazard zones, in additionto the requirements described in theabove reference, all valid provisionsfor safety, accident prevention andenvironmental protection must be com-plied with.
Packaging procedures (wrapping/unwrapping) may only be conductedoutside the explosion-hazard zone.
DANGER!
Danger to life if packagingprocedures are conducted inexplosion-hazard zones.
n Packaging procedures may onlybe conducted outside the explo-sion-hazard zone.
Transport, packaging and storage
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 35
6 Installation and initial startupInstallation and initial startup in non-explosion-hazard zones are describedin Chapter 5, "RVM/UA-2 ModuleBASICS". In addition, for installationand initial startup in explosion-hazardzones, the following sections must beobserved:
6.1 SafetyAll relevant safety-, accident preven-tion- and environmental protection reg-ulations must be followed for employ-ment in an explosion hazard zone.
6.2 ToolsTools, which may cause sparks, arenot to be employed. These tools mayonly be used when there is no poten-tially explosive atmosphere present.
The use of steel tools, of any kind, isprohibited in hazard zone 1, if there isrisk of explosion due to substances inexplosion hazard group IIC (in accord-ance with IEC/TR3 60079-20), (forexample, acetylene, hydrogen).
6.3 Protection of theflow monitor
The flow monitor must be installed insuch a way as to preclude damage byoutside force.
The facility operator is responsible forthe installation of an appropriateimpact protection shield.
6.4 Electrical connec-tion
Electrical connection is accomplishedthrough the connection cable leadingfrom the switch housing. All safetyadvisories contained in the OperatingInstructions for "RVM/UA-2 ModuleBASICS", Chapter 5, must beobserved. Additionally, for operation inexplosion-hazard zones, all valid provi-sions for safety, accident preventionand environmental protection must becomplied with.
6.5 Grounding thedevice
When installing the device in a pipesystem, ensure that the device isgrounded to the pipe system to avoid adangerous electrical potential differ-ence.
6.6 Contact protectionmeasures
Recommendations for contact protec-tion measures, when the device isemployed in a non-explosion-hazardzone, are described in chapter 5.9"Contact protection measures" of theOperating Instructions for "RVM/UA-2Module BASICS". When the device isemployed in an explosion-hazardzone, only those contact protectionmeasures may be taken, which are
Installation and initial startup
Contact protection measures
04.05.2020RVM/UA-2 Module ATEX Flow Monitor36
consistent with all valid safety andaccident prevention measures forexplosion-hazard zones and the speci-fications contained in these OperatingInstructions.
Installation and initial startup
Contact protection measures
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 37
7 OperationOperation is described in Chapter 6,"RVM/UA-2 Module BASICS". Allsafety- and hazard warnings containedin Chapter 6, "RVM/UA-2 ModuleBASICS", must be followed. For opera-tion in explosion-hazard zones, allvalid provisions for safety, accidentprevention and environmental protec-tion must be complied with.
Operation
04.05.2020RVM/UA-2 Module ATEX Flow Monitor38
8 TroubleshootingThe procedures in case of malfunctionare described in Chapter 7, "RVM/UA-2 Module BASICS". All safety- andhazard warnings, contained in Chapter7, "RVM/UA-2 Module BASICS", mustbe followed. Additionally, for operationin explosion-hazard zones, all validprovisions for safety, accident preven-tion and environmental protection mustbe complied with.
Troubleshooting
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 39
9 MaintenanceMaintenance procedures aredescribed in Chapter 8, "RVM/UA-2Module BASICS". All safety- andhazard warnings, contained in Chapter8, "RVM/UA-2 Module BASICS", mustbe followed. For operation in explo-sion-hazard zones, all valid provisionsfor safety, accident prevention andenvironmental protection must be com-plied with. Maintenance proceduresmay only be performed outside theexplosion-hazard zone.
DANGER!
Danger to life if maintenanceprocedures are performed inthe explosion-hazard zone– Maintenance procedures
may only be performed out-side the explosion-hazardzone
9.1 Return Materials9.1.1 Return Materials
AuthorizationFor products being returned, regard-less of the reason, the currently validprovisions of the returns policy set byMEISTER will apply. Return shipmentswhich do not comply with the returnspolicy may be refused by MEISTER atthe expense of the consignor.
Maintenance
Return Materials > Return Materials Authorization
04.05.2020RVM/UA-2 Module ATEX Flow Monitor40
10 Disassembly and disposalDisassembly and disposal proceduresare described in Chapter 9, "RVM/UA-2 Module BASICS". All safety- andhazard warnings, contained in Chapter9, "RVM/UA-2 Module BASICS", mustbe followed. For operation in explo-sion-hazard zones, all valid provisionsfor safety, accident prevention andenvironmental protection must be com-plied with. Disassembly of the devicemay only be performed outside theexplosion-hazard zone.
DANGER!
Danger to life if disassemblyprocedures are performed inthe explosion- hazard zone– Disassembly may only be
performed outside theexplosion hazard zone
– Disassembly in an explo-sion hazard zone may onlybe performed if there is norisk from an explosiveatmosphere
Disassembly and disposal
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 41
11 Technical data11.1 Dimension sheet
Technical data
Dimension sheet
04.05.2020RVM/UA-2 Module ATEX Flow Monitor42
11.2 General specificationsType Overall dimensions (mm)
G DN SW L1 L2 T
RVM/UA-2/02
1/4" 8 24 90 98 15
3/8" 10 24 90 119 12,5
1/2" 15 - 90 - 15
RVM/UA-2/06
1/4" 8 24 90 98 15
3/8" 10 24 90 119 12,5
1/2" 15 - 90 - 15
RVM/UA-2/1
1/4" 8 24 90 98 15
3/8" 10 24 90 119 12,5
1/2" 15 - 90 - 15
RVM/UA-2/3
1/4" 8 24 90 98 15
3/8" 10 24 90 119 12,5
1/2" 15 - 90 - 15
RVM/UA-2/7
1/4" 8 24 90 98 15
3/8" 10 24 90 119 12,5
1/2" 15 - 90 - 15
RVM/UA-2/13
1/4" 8 24 90 98 15
3/8" 10 24 90 119 12,5
1/2" 15 - 90 - 15
RVM/UA-2/20
1/2" 15 - 90 - 15
RVM/UA-2/30
1/2" 15 - 90 - 15
Technical data
General specifications
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 43
Type Overall dimensions (mm)
G D1 D2 A1 A2 A3 A4 Weight(g)
RVM/UA-2/02
1/4" 27,5 30 47 33 66 ca. 70 620
3/8" 27,5 30 47 33 66 ca. 70 670
1/2" - 30 47 33 66 ca. 70 570
RVM/UA-2/06
1/4" 27,5 30 47 33 66 ca. 70 620
3/8" 27,5 30 47 33 66 ca. 70 670
1/2" - 30 47 33 66 ca. 70 570
RVM/UA-2/1
1/4" 27,5 30 47 33 66 ca. 70 620
3/8" 27,5 30 47 33 66 ca. 70 670
1/2" - 30 47 33 66 ca. 70 570
RVM/UA-2/3
1/4" 27,5 30 47 33 66 ca. 70 620
3/8" 27,5 30 47 33 66 ca. 70 670
1/2" - 30 47 33 66 ca. 70 570
RVM/UA-2/7
1/4" 27,5 30 47 33 66 ca. 70 620
3/8" 27,5 30 47 33 66 ca. 70 670
1/2" - 30 47 33 66 ca. 70 570
RVM/UA-2/13
1/4" 27,5 30 47 33 66 ca. 70 620
3/8" 27,5 30 47 33 66 ca. 70 670
1/2" - 30 47 33 66 ca. 70 570
RVM/UA-2/20
1/2" - 30 47 33 66 ca. 70 570
RVM/UA-2/30
1/2" - 30 47 33 66 ca. 70 570
Technical data
General specifications
04.05.2020RVM/UA-2 Module ATEX Flow Monitor44
Type Overall dimensions (mm)
G D1 D2 A1 A2 A3 A4 Weight(g)
* NPT thread on request
** Connecting cable weight, 2m approx. 80g
11.3 Replacementparts
Technical data
Replacement parts
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 45
The following replacement parts drawing provides an example of the constructionof a RVM/UA-2 ATEX type flow monitor. The actual configuration may varydepending on the model.
Item Qty Description
1 1 Process connection (inlet)
2 2 O-ring (seal)
3 1 Device body
4 1 Float
5 3 Magnet
6 1 Spring
7 1 Threaded ring (outlet)
8 1 Process connection (outlet)
9 1 Cylinder pin (switch contact)
Technical data
Replacement parts
04.05.2020RVM/UA-2 Module ATEX Flow Monitor46
Item Qty Description
10 1 Switch contact (ATEX) with male connector
11 1 Female socket (ATEX) and gasket
12 1 Fixing screw (female socket)
13 1 Mechanical display
14 1 Set screw (switch contact)
Technical data
Replacement parts
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 47
12 AnnexThe required tools are specified inChapter 11.3 "Tools" of the OperatingInstructions for "RVM/UA-2 ModuleBASICS".
In explosion-hazard zones, tools whichmay cause sparks, are not to beemployed. These tools may only beemployed when there is no potentiallyexplosive atmosphere present.
The use of steel tools, of any kind, isprohibited in hazard zone 1, if there isa risk of explosion due to substancesin explosion hazard group IIC (inaccordance with IEC/TR3 60079-20),(for example, acetylene, hydrogen).
Annex
04.05.2020RVM/UA-2 Module ATEX Flow Monitor48
13 IndexAApplicable documents . . . . . . . . . 23
CCategorization
mechanical component . . . . . . 16
Contact . . . . . . . . . . . . . . . . . . . . 6Contact protection measures . . . . 36Copyright . . . . . . . . . . . . . . . . . . . 3Correct use . . . . . . . . . . . . . . . . . 8Customer service . . . . . . . . . . . . . 6
DDevice
electrical component . . . . . . . . 23
exterior . . . . . . . . . . . . . . . . . 14
interior . . . . . . . . . . . . . . . . . 14
Disassembly . . . . . . . . . . . . . . . . 41disposal . . . . . . . . . . . . . . . . . . . 41
EElectrical connection . . . . . . . . . . 36employment . . . . . . . . . . . . . . . . . 8Environmental protection regula-tions . . . . . . . . . . . . . . . . . . . . . 36
FFlow monitor
protection . . . . . . . . . . . . . . . 36
GGeneral
safety . . . . . . . . . . . . . . . . . . . 7
Grounding . . . . . . . . . . . . . . . . . 36
IInitial start-up . . . . . . . . . . . . . . . 36Installation . . . . . . . . . . . . . . . . . 36
LLabeling
switch contacts . . . . . . . . . . . . 34
Limitation of liability . . . . . . . . . . . . 3Limiting contacts . . . . . . . . . . . . . 23List of media . . . . . . . . . . . . . . . . 18
MMaintenance . . . . . . . . . . . . . . . . 40
OOperating data
mechanical component . . . . . . 32
switch unit . . . . . . . . . . . . . . . 32
Operation . . . . . . . . . . . . . . . . . . 38
PPackaging . . . . . . . . . . . . . . . . . 35Personnel requirements . . . . . . . . 12Precautions
explosion . . . . . . . . . . . . . . . . 11
general . . . . . . . . . . . . . . . . . 10
Index
04.05.2020 RVM/UA-2 Module ATEX Flow Monitor 49
Protective systems . . . . . . . . . . . 13
RReplacement parts . . . . . . . . . . . 45Return Materials Authorization . . . 40
SSafety equipment . . . . . . . . . . . . 13Safety information
mechanical component . . . . . . 15
Safety regulations . . . . . . . . . . . . 36Service . . . . . . . . . . . . . . . . . . . . 6Storage . . . . . . . . . . . . . . . . . . . 35Symbols used
in the instructions . . . . . . . . . . . 7
TTechnical data
Dimension sheet . . . . . . . . . . 42
General specifications . . . . . . . 43
Temperature class, internal: TX,external: TX . . . . . . . . . . . . . . . . 17Tools . . . . . . . . . . . . . . . . . . 36, 48Transport . . . . . . . . . . . . . . . . . . 35Troubleshooting . . . . . . . . . . . . . 39
WWarranty and guarantee provisions 6
Index