Download - Automatic Emergency Light
![Page 1: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/1.jpg)
SUBMITTED BY :MRIDUL SINGH RAWAT B120010243NIKITA DUTTA B120010260RAMITPAL SINGH KAMBOJ B120010320SAHIL SHARMA B120010345
AUTOMATIC EMERGENCY LIGHT
![Page 2: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/2.jpg)
BASIC INTRODUCTION
• Basically a battery packed light device.
• Sort of device that is automatically switched on when the light is switched off or there is a blackout.
• Common in commercial and standard residential buildings.
![Page 3: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/3.jpg)
NEED OF AUTOMATIC EMERGENCY LIGHT• Provides light when the ordinary lighting
fails due to a power cut.
• Required especially in villages where there are long power cuts.
• Important to install it near stairs or the place where level changes.
• Near safety signs it should be installed.
![Page 4: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/4.jpg)
SOME PLACES REQUIRE EMERGENCY LIGHT
Near StairsNear Change
of Levels
![Page 5: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/5.jpg)
WORKING PRINCIPLE• Automatic Emergency Light has a light sensor
installed in it known as Light Dependent Resistor(LDR).
• When the intensity of light falling on it decreases, its resistance decreases.
• As the circuit is completed the bulb installed glows.
• When the intensity of light falling on LDR is enough resistance of LDR increases and the circuit remains incomplete and bulb doesn’t glows.
![Page 6: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/6.jpg)
THE MISCONCEPTION
• Automatic Emergency light is often considered same as a light device running on an inverter.
• It is considered a device which has its one end connected to a power source and when the power supply is cut, the bulb glows with the power of inverter.
BULB RUN BY AN INVERTER
![Page 7: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/7.jpg)
CIRCUIT DIAGRAM
![Page 8: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/8.jpg)
WORKING• Deep discharge is taken care by the LED
characteristic and over charge protection is taken care by the fixed voltage regulator.
• This uses a simple 3Pin fixed regulator which has a built in current limiting circuit.
• The only required adjustment is the preset which has to be set to ensure the LEDs just light up.
• The 5mm LDR is just mounted on top of the emergency light as shown in the photograph. LDR is used to avoid it lighting up during day time or when the room lights are ON.
• 2 LEDs are used in series; the dropping resistance is avoided and 2 LEDs light up with current that is required for a single LED, by which energy is saved to a great extent.
![Page 9: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/9.jpg)
ADVANTAGES
• Battery Efficient.
• Pollution free.
• Easy to use.
• Very cheap under Rs(200-300).
• Easy to install anywhere.
VERY CHEAP
ECO FRIENDLYBATTERY EFFICIENT
![Page 10: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/10.jpg)
DISADVANTAGES
• Not Durable.
• A bit delicate circuit.
![Page 11: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/11.jpg)
REFERENCES• http://en.wikipedia.org/wiki/Emergency_light
• http://www.icel.co.uk/media/ICEL_LED_Emergency_Luminaires_EE_AP PROVED_JH.pdf
• http://www.candlepowerforums.com/vb/showthread.php?262331-Automatic-Emergency-Lighting
• http://www.radiolocman.com/shem/schematics.html?di=50653
• http://www.electronicsforu.com/electronicsforu/circuitarchives/view_article.asp?sno=365&article_type=1&id=516&tt=unhot
![Page 12: Automatic Emergency Light](https://reader036.vdocuments.us/reader036/viewer/2022081412/5413194e8d7f72084e8b479e/html5/thumbnails/12.jpg)