energy
February 24, 2017
Becky J. Palmer President, West Texas Division
Atmos Energy Corporation 6606 66th Street Lubbock, Texas, 79424 Tel: 806-798-4472 Fax: 806-798-4494 [email protected]
TO THE GOVERNING BODY OF AMARILLO, LUBBOCK, DALHART, AND CHANNING -MUNICIPALITIES SERVED BY ATMOS ENERGY CORPORATION'S WEST TEXAS DIVISION
Dear City Official:
Please find enclosed the 2016 Gas Reliability Infrastructure Program ("GRIP") interim rate adjustment
filing for the incorporated areas of Amarillo, Lubbock, Dalhart, and Channing (collectively "Cities"), located
in Atmos Energy Corporation's ("Atmos Energy" or "the Company") West Texas Division ("WTX Division").
This filing includes information labeled as follows:
I. Tab 1 - Interim Cost Recovery and Rate Adjustment Report submitted pursuant to Texas Utilities Code § 104.301(c), which contains the approved Interim Rate Adjustment (IRA) forms of the Railroad Commission of Texas.
2. Tab 2 - Tariffs.
3. Tab 3 - Annual Earnings Monitoring Report submitted pursuant to Texas Utilities Code § 104.301(±).
4. Tab 4-Project Reports which, in accordance with Texas Utilities Code§ 104.301(e), describe the investment projects completed and placed in service for the WTX Division from January 1, 2016 through December 31, 2016. The Project Report includes the cost, need, and customers benefited by change in investment.
5. Tab 5 - The Relocation Project Report providing certain supplemental information about relocation project costs included in the Project Report for the period of January 1, 2016 through December 31, 2016.
6. Tab 6 - The affidavits of Becky J. Palmer and Barbara W. Myers. Ms. Palmer's affidavits attest to: (i) the method and date on which notice will be given to all customers; and (ii) relocations. Ms. Myers provides an affidavit which verifies that the WTX Division's books and records are kept in accordance with the rules of the Railroad Commission of Texas and verifies that the schedules enclosed are summaries of the WTX Division's books and records related to the invested capital used by the Company in providing utility service.
The tariffs included in Tab 2 will be effective on April 25, '.2,017. These tariffs establish an IRA that
will affect the monthly customer charge or meter charge applicable within the Cities. As authorized under
Section 104.301 of the Texas Utilities Code, the IRA will recover the difference between the values of invested
capital for the WTX Division's system as of December 31, 2016, and the value of the invested capital for the
WTX Division's system as of December 31, 2015. This investment is used to provide gas utility services and
the IRA will remain in effect until the issuance of a final decision in a rate case that is filed after the
implementation of these tariffs. All amounts collected under these tariffs are subject to refund.
The IRA set forth in the tariffs accompanying this filing was calculated by applying the methodologies
approved by the Railroad Commission of Texas in GUD No. 1017 4 and the factors established in paragraph 8
and Exhibit C of the 2013 Rate Filing Settlement Agreement. The 2013 Rate Filing Settlement Agreement
established the latest effective rates for customers within the Cities. Upon approval, the IRA will be added to
the customer/meter charges that are effective for customers within the Cities.
Under Section 104.301, as amended, Cities are provided the opportunity to review the filing and
either: (i) take final action before April 25, 2017; or (ii) suspend the effective date of these tariffs for forty-five
( 45) days after April 25, 2017. The source documentation supporting the new investment is available for
review through Atmos Energy's electronic databases. If you wish to schedule an opportunity to review the
electronic databases or any hard copy project files related to the new investment, please contact me. In
addition, the Company has elected to make certain adjustments in this filing. These adjustments are detailed in
the Company's IRA schedules. Elective adjustments have been made to remove certain employee expenses
identified via a detailed review of every employee expense report for items recorded to capital projects for the
Shared Services Division and the WTX Division. These expenses have been removed to reduce controversy.
The Company reserves its right to seek recovery of these expenses in a rate proceeding involving a review of
the Company's invested capital through at least December 31, 2016.
Notice of this proceeding will be provided to affected customers in the incorporated areas of the Cities
of Amarillo, Lubbock, Dalhart and Channing by bill insert or individual mailing within 45 days after the date
of this filing in accordance with Section 104.301. The Company respectfully requests that the Cities expedite
the review of the filing and attempt to take final action by April 25, 2017, in order to avoid the need to suspend
consideration of the filing.
In closing, please accept for filing this cover correspondence, the above mentioned tariffs, filing
package and enclosures and return the enclosed copy of this Jetter with your file mark thereon to acknowledge
such filings for our records.
Respectfully submitted,
Becky J. Palmer President West Texas Division
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
GAS RELIABILITY INFRASTRUCTURE PROGRAM
TARIFF FILING
TABLE OF CONTENTS
INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT IRA Schedules
TARIFFS
EARNINGS MONITORING REPORT EMR Schedules
PROJECT REPORTS Detail Project Report - West Texas Division & West Texas General Office
Detail Project Report - Shared Services General Office & Customer Support
RELOCATION PROJECT REPORT Detail Relocation Project Report - West Texas Division & West Texas General Office
AFFIDAVITS Becky J. Palmer (2)
Barbara W. Myers
Tab 1
Tab 2
Tab 3
Tab4
Tab 5
Tab 6
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
GAS RELIABILITY INFRASTRUCTURE PROGRAM
INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
Interim Cost Recovery and Rate Adjustment Report
INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
OF
ATMOS ENERGY, WEST TEXAS DIVISION
TO THE CITIES OF AMARILLO, LUBBOCK, DALHART AND CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
FEBRUARY 24, 2017
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
GENERAL QUESTIONS
If additional space is required, please attach pages providing the requested information.
1. State the exact name of the utility.
Atmos Energy, West Texas Division
2. State the date when the utility was originally organized.
February 6, 1981
3. Report any change in name during the most recent year and state the effective date.
None.
4. State the name, title, phone number, email address, and office address of the officer
of the utility to whom correspondence should be addressed concerning this report.
Philip Littlejohn, Vice President of Rates and Regulatory Affairs
6606 66th Street
Lubbock, Texas 79424
Phone: 806. 798.4449
Email: phi Ii [email protected]
5. State the name, title, phone number, email address, and office address of any other
individual designated by the utility to answer questions regarding this report (optional)
6. State the location of the office where the Company's accounts and records are kept.
Atmos Energy Corporation
5420 LBJ Freeway
Dallas, Texas 75240
7. IF THIS IS A REVISED REPORT, provide the schedule number, line number, and
column designation where each change input data appears.
IRA-1
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
NOTICE
1. Attach Notice
Attached are sample copies of the Notices sent to the following Rate Schedule Customers:
Residential Gas Service
Commercial Gas Service
Industrial Gas Service
Transportation Service
Public Authority· Gas Service
2. Affidavit that Notice was provided by mail-out or bill insert.
Included in the filing is an Affidavit by Becky Palmer that notice will be provided.
IRA- 2
CUSTOMER NOTICE
On February 24, 2017, the West Texas Division of Atmos Energy Corporation (the "Company") filed an application for an interim rate adjustment with the Cities of Amarillo, Lubbock, Dalhart and Channing (collectively "ALDC Cities") pursuant to Texas Utilities Code Section 104.301. The proposed interim rate adjustment will apply to all customers served by the Company within the incorporated areas of the ALDC Cities. The proposed interim rate adjustment provides cost recovery for the additional capital investment incurred by the Company during the twelve month period ending December 31, 2016, that is used and useful in providing utility service. The costs to be recovered through the proposed interim rate adjustment are not included in the rates currently in effect within the incorporated areas of the ALDC Cities.
The proposed effective date for implementation of the interim rate adjustment is April 25, 201 7. The proposed interim rate adjustment will increase the customer/meter charges that are applicable to residential, commercial, industrial sales/transport and public authority customers within the incorporated areas of the ALDC Cities as follows:
Rate Current Proposed 2016 Interim Adjusted Charge
Increase Each Schedules Customer Charge Adjustment Bill
Residential $18.82 $2.34 $21.16 $2.34 Gas Service per customer per month per customer per month per customer per month
Commercial Gas $44.19 $6.45 $50.64 $6.45 Service per customer per month per customer per month per customer per month
Industrial Sales I $435.16 $85.58 $520.74 Transportation Gas
per customer per month per customer per month per customer per month $85.58 Service
Public Authority $115.17 $18.55 $133.72 $18.55 Gas Service per customer per month per customer per month per customer per month
This increase constitutes a major change in the Company's rates as defined in Texas Utilities Code Section 104.101. Persons with questions or who want more information about this filing may contact the Company at 1-888-286-6700. A copy of the filing will be posted at the following Web site: www.atmosenergy.com/grip and will be available for inspection during normal business hours at the Company's office located at 6606 66th Street, Lubbock, Texas 79424.
Any affected. person may file written comments or a protest concerning the proposed interim rate adjustment with the regulatory authority having jurisdiction over this filing.
Atmos Energy (la Compafiia) ha presentado una solicitud para un ajuste interino de tarifas, el cual propone aumentar los cargos de sus clientes seglin indicado en la tabla. Este aumento constituye un cambio mayor en las tarifas de la Compafiia, tal como es definido en la secci6n 104.101 del C6digo de Utilidades de Texas. Aquellas personas con preguntas o que deseen mas informaci6n sobre esta solicitud pueden ponerse en contacto con la Compafiia al 1-888-286-6700. Pueden ver una copia de la solicitud en:
www.atmosenergy.com/grip. Ademas la solicitud estara disponible para inspecci6n durante las horas normales de negocio en la oficina de la Compafila situada en 6606 66th Street, Lubbock, Texas 79424.
Cualquier persona afectada puede hacer comentarios por escrito o presentar una protesta con respecto a este propuesto ajuste interino con la autoridad regulatoria correspondiente a esta solicitud.
Line
Number
1 2
3
4
5
6
7
8
9
10
11 12
13
14
15
16
17
18
19
20
21
22
23
24
25
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
SUMMARY
Adjusted Balance
Description at 12/31/2015 [a] [b]
Utillty Plant Investment $ 659,144,061
Accumulated Depreciation (151,534,558)
Net Investment $ 507,609,503
Exclusions from Filing (1)
Adjusted Net Investment
lncrease/(Decrease) in Net Investment
Authorized Return on Capital - Per GUD 10170
Change in Return on Net Investment
Change in Depreciation Expense
Change in Ad Valorem Tax
Change in Federal Tax
Change in Revenue Requirement
Annual Number of Bills
Increase per Bill per Month (to be applied to Monthly Customer Charge) Current
Rates
Monthly Residential Customer Charge - all areas $ 18.82
Monthly Commercial Customer Charge - all areas $ 44.19 Monthly Industrial Sales\ Transport Customer Charge - all areas $ 435.16 Monthly Public Authority Customer Charge - all areas $ 115.17
Note 1: Voluntary removal of employee expenses and rate base adjustments from the 2013 WTX SOI and prior dockets.
Increase in Adjusted Balance
WTX Division at 12/31/2016 [c] [d]
$ 66,247,693 $ 725,391,754 (5,634,177) (157,168,735)
$ 60,613,516 $ 568,223,019
$ 382,946
$ 60,230,570
$ 60,230,570
8.57%
$ 5,160,790
2,649,908
624,319 1,771,414
$ 10,206,431
3,598,801
IRA Proposed
Increase Rates
$ 2.34 $ 21.16
$ 6.45 $ 50.64
$ 85.58 $ 520.74
$ 18.55 $ 133.72
IRA-3
1 2 3
4
5
6 7
8
9
10
11
12
13 14
15
ATMOS ENERGY, WEST TEXAS DIVISION 2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016 SUMMARY
Current and Proposed Bill Information - With Gas Cost
Current Proposed
Residential Customers
Average Monthly Bill @ 52.69 Cd-Amarillo Incorporated $ 41.64 $ 43.98
Average Monthly Bill@ 52.69 Ccf- Lubbock Incorporated $ 43.05 $ 45.39
Commercial Customers
Average Monthly Bill@ 239.72 Cd-Amarillo Incorporated $ 152.57 $ 159.02 Average Monthly Bill@ 239.72 Ccf- Lubbock Incorporated $ 151.52 $ 157.97
Industrial Sales\ Transport Customers
Average Monthly Bill @ 3950.03 Ccf -Amarillo Incorporated $ 2,276.71 $ 2,362.29 Average Monthly Bill @ 3950.03 Ccf - Lubbock Incorporated $ 2,111.60 $ 2,197.18
Public Authority Customers
Average Monthly Bill@ 809.72 Ccf-Amarillo Incorporated $ 487.67 $ 506.22
Average Monthly Bill@ 809.72 Ccf- Lubbock Incorporated $ 504.31 $ 522.86
Difference %Change
$ 2.34 5.62%
$ 2.34 5.43%
$ 6.45 4.23%
$ 6.45 4.26%
$ 85.58 3.76%
$ 85.58 4.05%
$ 18.55 3.80%
$ 18.55 3.68%
IRA-3
1
2
3
4
5
6
7
8
9
10
11 - 12
13 14
15
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
SUMMARY
Current and Proposed Bill Information - Without Gas Cost
Current Proposed Residential Customers
Average Monthly Bill @ 52.69 Ccf -Amarillo Incorporated $ 23.96 $ 26.30 Average Monthly Bill @ 52.69 Ccf - Lubbock Incorporated $ 25.38 $ 27.72
Commercial Customers
Average Monthly Bill @ 239.72 Ccf-Amarillo Incorporated $ 72.16 $ 78.61
Average Monthly Bill @ 239.72 Ccf- Lubbock Incorporated $ 71.10 $ 77.55
Industrial Sales\ Transport Customers
Average Monthly Bill @ 3950.03 Ccf - Amarillo Incorporated $ 951.63 $ 1,037.21 Average Monthly Bill @ 3950.03 Ccf - Lubbock Incorporated $ 786.52 $ 872.10
Public Authority Customers
Average Monthly Bill @ 809. 72 Ccf- Amarillo Incorporated $ 216.04 $ 234.59 Average Monthly Bill@ 809.72 Ccf- Lubbock Incorporated $ 232.68 $ 251.23
Difference % Change
$ 2.34 9.77%
$ 2.34 9.22%
$ 6.45 8.94%
$ 6.45 9.07%
$ 85.58 8.99%
$ 85.58 10.88%
$ 18.55 8.59%
$ 18.55 7.97%
IRA-3
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
TARIFFS
Attached are the following proposed tariffs:
Residential Gas Service
Commercial Gas Service
Industrial Gas Service
Proposed Implementation Date:
Public Authority Gas Service
Transportation Service
April 25, 2017
IRA-4
Line
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Description
[a]
Non-Revenue Related
Ad Valorem Tax
Revenue Related
State Gross Receipts Tax
City Franchise Tax
State Transportation Tax
Total Revenue Related Taxes
Total Taxes Other Than Income
Note:
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
REVENUE RELATED AND OTHER TAXES
12 Month End
As Adjusted
Total (1) Adjustments (at Present Rates) Adjustments (2)
[b] [c] [d] [e]
$ 4,133,461 $ 464,194 $ 4,597,655 $ 624,319
$ 1,240,602 Note 3 Note 3 Note 3
3,653,872 Note 3 Note 3 Note 3
1,762 Note 3 Note 3 Note 3
$ 4,896,237 Note 3 Note3 Note 3
$ 9,029,698 Note 3 Note 3 Note 3
1. Column (b) is the amount filed in the 2013 WTX SOI Cost of Service.
12 Month End
As Adjusted
(at Proposed Rates)
[f]
$ 5,221,975
Note3
Note 3
Note 3
Note 3
Note3
2. Adjustment to proposed rates using the authorized property tax factor in the 2013 WTX SOI Settlement Agreement with ALDC.
3. Revenue Related Taxes are recovered through Rider FF and Rider TAX.
Change
[g]
$ 624,319
Note 3
Note 3
Note 3
Note 3
Note 3
IRA-5
Line
Number
1
2
3
4
5
6
7
8
9
10
11
12
13 14
15
16
17
18
19
20
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
FEDERAL INCOME TAX
Description Prior Year Amount Current Year [a] [b] [c] [d]
Return on Investment
Invested Capital (Rate Base) $ 507,609,503 $ 568,223,019 Rate of Return - Per GUD 10174/10170 8.57% 8.57%
Return on Investment $ 43,493,960
Interest Expense
Invested Capital (Rate Base) $ 507,609,503 $ 568,223,019
Weighted Cost of Debt- Per GUD 10174/10170 3.14% 3.14%
Interest Expense $ 15,943,702
After Tax Income $ 27,550,258
Gross Up Factor 1.538461538
Before Tax Return $ 42,385,012
Federal Income Tax Rate 35%
Federal Income Tax $ 14,834,754
CHANGE IN FEDERAL INCOME TAX $ 1,771,414
Amount
[e]
$ 48,687,562
$ 17,847,536
$ 30,840,027
1.538461538
$ 47,446,195
35%
$ 16,606,168
IRA- 6
ATMOS ENERGY, WEST TEXAS DIVISION 2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016 INVESTMENT DETAIL- PREVIOUS BALANCE
Line FERC 2015 Adjusted RRC Approved Annual Accumulated
Number Account No. Description Original Cost Depr. Rate Depreciation Depreciation Net Plant (1) [a] [b] [c] [d] [e] [f] [g]
1 1. INTANGIBLE PLANT
2 302 Franchises and Consents $ 4,264
3
4 2. DISTRIBUTION PLANT
5 374 Land and Land Rights $ 365,849
6 375 Structures and Improvements 353,277
7 376 Mains 336,030,887
8 377 Compressor Station Equipment 217,930
9 378-379 M&R Station Equipment 15,673,710
10 380 Services 124,575,861
11 381-384 Meters and House Regulators 105,763,449
12 385 Industrial M&R Equipment 3,492,415
13 386-387 Other Property and Equipment 1,620,931
14 Total Distribution Plant $ 588,094,309
15
16 3. GENERAL PLANT
17 389 Land $ 2,654,724
18 390 Structures and Improvements 22,925,598
19 391 Office Furniture and Equipment 3,062,261
20 392 Transportation Equipment 402,732
21 393-395 Stores, Tools, and Lab Equipment 5,915,199
22 396 Power Operated Equipment 1,191,217
23 397 Communication Equipment 1,355,501
24 398 Miscellaneous Equipment 3,696,725
25 399 OtherTangible Property 29,841,532
26 Total General Plant $ 71,045,488
27
28 TOTAL $ 659,144,061 4.00% $ 26,365,762 $ (151,534,558) $ 507,609,503
29
30 Note:
31 1. Reflects the net plant amount as of December 311 2015 per the approved 2015 Amarillo, Lubbock, Dalhart and Channing GRIP Filing.
IRA-7
ATMOS ENERGY, WEST TEXAS DIVISION 2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016 INVESTMENT DETAIL - CURRENT BALANCE
Line FERC 2016 Adjusted RRC Approved Annual Accumulated
Number Account No. Description Original Cost (1) Depr. Rate Depreciation Depreciation Net Plant [a] [b] [c] [d] [e] [f] [g]
1 1. INTANGIBLE PLANT
2 302 Franchises and Consents $ 4,264
3
4 2. DISTRIBUTION PLANT 5 374 Land and Land Rights $ 369,864
6 375 Structures and Improvements 353,277
7 376 Mains 380,300,662
8 377 Compressor Station Equipment 217,930
9 378-379 M&R Station Equipment 17,594,993
10 380 Services 132, 763,104
11 381-384 Meters and House Regulators 113,837,866
12 385 Industrial M&R Equipment 3,708,514
13 386-387 Other Property and Equipment 1,620,931
14 Total Distribution Plant $ 650,767,140
15
16 3. GENERAL PLANT 17 389 Land $ 6,530,701
18 390 Structures and Improvements 23,220,910
19 391 Office Furniture and Equipment 3,275,059
20 392 Transportation Equipment 471,412
21 393-395 Stores, Tools, and Lab Equipment 6,023,781
22 396 Power Operated Equipment 1,104,526
23 397 Communication Equipment 1,129,179
24 398 Miscellaneous Equipment 5,894,347
25 399 Other Tangible Property 26,970,435
26 Total General Plant $ 74,620,351
27
28 TOTAL $ 725,391,754 4.00% $ 29,015,670 $ (157,168,735) $ 568,223,019
IRA-8
Line FERC
Number Account No.
[a]
1
2 302
3
4
5 374
6 375
7 376
8 377
9 378-379
10 380
11 381-384
12 385
13 386-387
14
15
16
17 389
18 390
19 391
20 392
21 393-395
22 396
23 397
24 398
25 399
26
27
28
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
INVESTMENT DETAIL - NET CHANGE
RRC Approved Annual
Description Net Change Depr. Rate Depreciation
[b] [c] [d] [e]
1. INTANGIBLE PLANT Franchises and Consents s 2. DISTRIBUTION PLANT
Land and Land Rights s 4,015
Structures and Improvements
Malns 44,269,775
Compressor Station Equipment
M&R Station Equipment 1,921,283
Services 8,187,243
Meters and House Regulators 8,074,416
Industrial M&R Equipment 216,099
Other Property and Equipment
Total Distribution Plant s 62,672,831
3. GENERAL PLANT
Land s 3,875,978
Structures and Improvements 295,311
Office Furniture and Equipment 212,798
Transportation Equipment 68,680
Stores, Tools, and Lab Equipment 108,582
Power Operated Equipment (86,690)
Communication Equipment (226,322)
Miscellaneous Equipment 2,197,622
Other Tangible Property (2,871,097)
Total General Plant s 3,574,862
TOTAL s 66,247,693 4.00% s 2,649,908
Accumulated
Depreciation Net Plant
[f] [g]
s (5,634,177) s 60,613,516
IRA-9
ATMOS ENERGY, WESTTEXAS DIVISION 2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016 INVESTMENT DETAIL - ADDITIONS
Line FERC RRC Approved Annual Accumulated Number Account No. Description Original Cost Depr. Rate Depreciation Depreciation Net Plant
[a] [bl [c] [d] [e] [f] [g]
1 1. INTANGIBLE PLANT 2 302 Franchises and Consents .J 3 4 2. DISTRIBUTION PLANT 5 374 Land and Land Rights $ 4,051 6 375 Structures and Improvements
7 376 Mains 45,502,820 8 377 Compressor Station Equipment
9 378-379 M&R Station Equipment 1,925,330 10 380 Services 8,589,260 11 381-384 Meters and House Regulators 15,022,577 12 385 Industrial M&R Equipment 211,886 13 386-387 Other Property and Equipment
14 Total Distribution Plant $ 71,255,924 15 16 3. GENERAL PLANT 17 389 Land $ 3,871,971 18 390 Structures and Improvements 414,142 19 391 Office Furniture and Equipment 338,964 20 392 Transportation Equipment 46,213 21 393-395 Stores, Tools, and Lab Equipment 948,947 22 396 Power Operated Equipment 46,367 23 397 Communication Equipment (3,262) 24 398 Miscellaneous Equipment 2,222,460 25 399 Other Tangible Property 3,203,455 26 Total General Plant $ 11,089,257 27 28 TOTAL $ 82,345,181 29 Rate Base Adjustments (1) 1,629,190 30 ADJUSTED TOTAL $ 83,974,371 4.00% $ 3,358,975
IRA-10
ATMOS ENERGY, WEST TEXAS DIVISION 2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016 INVESTMENT DETAIL - FOOTNOTES
Per the most recent rate filing, 2013 WTX Statement of Intent - City Settlement:
1. None.
IRA-11
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
INFRASTRUCTURE DETAIL - ADDITIONS
PLEASE SEE TAB 4 FOR DETAILED PROJECT INFORMATION
IRA-12
Line FERC
Number Account No.
[a]
1
2 302
3
4
5 374
6 375
7 376
8 377
9 378-379
10 380
11 381-384
12 385
13 386-387
14
15
16
17 389
18 390
19 391
20 392
21 393-395
22 396
23 397
24 398
25 399
26
27
28
ATMOS ENERGY, WEST TEXAS DIVISION 2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016 INVESTMENT DETAIL - RETIREMENTS AND TRANSFERS
RRC Approved Annual
Description Original Cost Depr. Rate Depreciation
[b] [c] [d] [e]
1. INTANGIBLE PLANT Franchises and Consents -1
2. DISTRIBUTION PLANT
Land and Land Rights $ Structures and Improvements
Mains {2,192,415)
Compressor Station Equipment
M&R Station Equipment (7,090)
Services (375,798)
Meters and House Regulators {7,186,307)
Industrial M&R Equipment
Other Property and Equipment
Total Distribution Plant $ {9,761,610)
3. GENERAL PLANT
Land $ Structures and Improvements (176,976)
Office Furniture and Equipment {88,602)
Transportation Equipment 22,221
Stores, Tools, and Lab Equipment (842,032)
Power Operated Equipment (133,057)
Communication Equipment (228,389)
Miscellaneous Equipment (30,212)
Other Tangible Property {6,488,022)
Total General Plant $ (7,965,068)
TOTAL $ (17,726,678) 4.00% $ (709,067)
Accumulated
Depreciation Net Plant
[f] [g]
IRA-13
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
INFRASTRUCTURE DETAIL· RETIREMENTS AND TRANSFERS
PLEASE SEE TAB 4 FOR DETAILED PROJECT INFORMATION
IRA-14
Line
Number
1 2
3 4 5
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
WEIGHTED AVERAGE COST OF CAPITAL
GUD 10170 FACTORS PER 2013 WEST TEXAS SOI SETTLEMENT
Percent Weighted
Description of Total Cost Cost [a] [b] [c] [d] = [b] x [c]
Common Equity 51.69% 10.50% 5.43% Long-Term Debt 48.31% 6.50% 3.14%
Total 100.00% 8.57%
IRA-15
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
ALLOCATION OF INVESTMENT RECOVERY
Allocation Factors Per Rate Case - 2013 WTX Statement of Intent - ALDC Settlement (See Exhibit C)
Residential
Commercial
Industrial \Transport Public Authority
Total System
Allocation Factors Requested in this filing
Residential Commercial
Industrial\ Transport Public Authority
Total System
New Investment Recovery Distribution
Requested Recovery Amount
Residential
Commercial Industrial\ Transport
Public Authority Total System
Annual Number of Bills
75.13% 18.39%
2.16% 4.32%
100.00%
75.13% 18.39%
2.16% 4.32%
100.00%
75.13% 18.39%
2.16% 4.32%
100.00%
$
$
$
10,206,431
7,668,092 1,876,963
220,459 440,918
10,206,432
Total System Amarillo Incorporated Lubbock Incorporated Residential
Commercial
Industrial\ Transport
Public Authority Total
3,281,555 290,907
2,576 23,763
3,598,801
786,683 765,202 69,941 69,055
218 468 3,538 1,578
860,380 836,303
IRA-16
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION 2016 ANNUAL GAS RELIABILITY INFRASTRUCTURE PROGRAM RATE
ADJUSTMENT FOR THE INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART, AND CHANNING
Annual Interim Cost Recovery and Rate Adjustment Report Attestation
I certify that I am the responsible official of Atmos Energy Corporation, West Texas Division; that I have examined the foregoing report; that to the best of my knowledge, information, and belief, all statements of fact contained in the said report are true and the said report is a correct statement of the business and affairs of the above-named respondent in respect to each and every matter set forth therein during the period from January 1, 2016 to December 31, 2016 inclusive.
I understand until the issuance of a final order or decision by a regulatory authority in a rate case that is filed after the implementation of a tariff or rate schedule under this section, all amounts collected under the tariff or rate schedule before the filing of the rate case are subject to refund.
SWORN TO AND SUBSCRIBED before me on this the ibts. day of February 2017.
~'~~V~ft''-' GISELLE R HEROY ~~ ...... Q!..~ • §'f(:....Ao:·;t;~ Notary ·Public, State of Texas \~\"5Q.i Comro. Expires 09-01·2020 "~,~Hr.,\''' Notary m 13oso4B4-~
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
GAS RELIABILITY INFRASTRUCTURE PROGRAM
INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
Tariffs
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: RESIDENTIAL GAS SERVICE
APPLICABLE TO: AMARILLO SERVICE AREA - Inside City Limits (ICL)
EFFECTIVE DATE: I
Availability
This schedule is applicable to general use by Residential customers for heating, cooking, refrigeration, water heatlng and other similar type uses. This schedule ls not available for service to premises with an alternative supply of natural gas.
Monthly Rate
Customer Charge 1 $ 14.75
Interim Rate Adjustment ("IRA") 2 $ 6.41
Total Customer Charge $21.16
Consumption Charge $ 0.09760 per Ccf
The West Texas Division Gas Cost Adjustment Rider applies to this schedule.
The West Texas Division Weather Normallzation Adjustment Rider applies to this schedule.
The West Texas Division Rider TAX applies to this schedule.
The West Texas Division Rider FF applies to this schedule.
The West Texas Amarillo, Lubbock, Dalhart, and Ch?nnlng Interim Rate Adjustment applies to this schedule.
Miscellaneous Charges: Plus an amount for miscellaneous charges calculated in accordance with the applicable rider(s).
Notes: 1 - Per the 2013 West Texas Statement of Intent Amarillo, Lubbock, Dalhart, and Channing Settlement Agreement.
2 - 2014 IRA- $2.32; 2015 IRA- $1.75; 2016 IRA- $2.34.
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: COMMERCIAL GAS SERVICE
APPLICABLE TO: AMARILLO SERVICE AREA - Inside City Limits (ICL)
EFFECTIVE DATE: I
Availability
This schedule is applicable to Commercial customers, including hospitals and churches, for heating, cooking, refrigeration, water heating and other similar type uses. This schedule is not available for service to premises with an alternative supply of natural gas.
Monthly Rate
Customer Charge 1 $ 33.00
Interim Rate Adjustment ("IRA") 2 $17.64
Total Customer Charge $ 50.64
Consumption Charge $ 0.11666 per Ccf
The West Texas Dlvision Gas Cost Adjustment Rider applies to this schedule.
The West Texas Division Weather Normalization Adjustment Rider applies to this schedule.
The West Texas Division Rlder TAX applies to this schedule.
The West Texas Division Rider FF applies to this schedule.
The West Texas Amarillo, Lubbock, Dalhart, and Channing lnterlm Rate Adjustment applies to this schedule.
Miscellaneous Charges: Plus an amount for miscellaneous charges calculated in accordance with the applfcable rider(s}.
Notes: 1 - Per the 2013 West Texas Statement of Intent Amarillo, Lubbock, Dalhart, and Channing Settlement Agreement.
2 - 2014 IRA- $6.38; 2015 IRA - $4.81; 2016 IRA- $6.45.
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: INDUSTRIAL GAS SERVICE
APPLICABLE TO: AMARILLO SERVICE AREA - Inside City Limits (ICL)
EFFECTIVE DATE: I Availability
This schedule is applicable to the sales to any industrial or commercial customer whose predominant use of natural gas is other than space heating, cooking, water heating or other similar type uses. Service under this schedule is available to eligible customers following execution of a contract specifying the maximum hourly load. This schedule is not available for service to premises with an alternative supply of natural gas.
Monthly Rate
Customer Charge 1 $ 300.00
Interim Rate Adjustment ("IRA") 2 $ 220.74
Total Customer Charge $ 520.74
Consumption Charge $ 0.13075 per Ccf
The West Texas Division Gas Cost Adjustment Rider applies to this schedule.
The West Texas Division Rider TAX applies to this schedule.
The West Texas Division Rider FF applies to this schedule.
The West Texas Division Amarillo, Lubbock, Dalhart, and Channing Interim Rate Adjustment applies to this schedule.
Miscellaneous Charges: Plus an amount for miscellaneous charges calculated in accordance with the applicable rider(s).
Notes: 1 - Per the 2013 West Texas Statement of Intent Amarillo, ~ubbock, Dalhart, and Channing Settlement Agreement.
2 - 2014 IRA- $76.67; 2015 IRA- $58.49; 2016 IRA- $85.58.
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: PUBLIC AUTHORITY GAS SERVICE
APPLICABLE TO: AMARILLO SERVICE AREA - Inside City Limits (JCL)
EFFECTIVE DATE: I
Availability
This schedule ls applicable to general use by Public Authority type customers, including publlc schools, for heating, cooking, refrigeration, water heating and other similar type uses. This schedule is not available for service to premises with an alternative supply of natural gas.
Monthly Rate
Customer Charge 1 $ 82.00
Interim Rate Adjustment ("IRA") 2 $ 51.72
Total Customer Charge $133.72
Consumption Charge $ 0.12457 per Ccf
The West Texas Division Gas Cost Adjustment Rider applies to this schedule.
The West Texas Division Weather Normallzation Adjustment Rider applies to this schedule.
The West Texas Division Rider TAX applles to this schedule.
The West Texas Division Rider FF applies to this schedule.
The West Texas Division Amarillo, Lubbock, Dalhart, and Channing Interim Rate Adjustment applies to this schedule.
Miscellaneous Charges: Plus an amount for miscellaneous charges calculated in accordance with the applicable rider(s).
Notes: 1 - Per the 2013 West Texas Statement of Intent Amarillo, Lubbock, Dalhart, and Channing Settlement Agreement.
2 - 2014 IRA - $18.96; 2015 IRA - $14.21; 2016 IRA- $18.55.
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: TRANSPORTATION SERVICE
APPLICABLE TO: AMARILLO SERVICE AREA - Inside City Limits (ICL)
EFFECTIVE DATE: I
Application Applicable, in the event that Company has entered into a Transportation Agreement, to a customer directly connected to the Atmos Energy Corp., West Texas Division Distribution System for the transportation of all natural gas supplied by Customer or Customer's agent at one Point of Delivery for use in Customer's facility with an estimated annual usage greater than 100,000 Ccf per meter.
Type of Service Where service of the type desired by Customer is not already available at the Point of Delivery, additional charges and special contract arrangements between Company and Customer may be requlred prior to service being furnished.
Monthly Rate Customer's bill will be calculated by adding the following Customer and Ccf charges to the amounts and quantities due under the rlders listed below:
Customer Charge per Meter 1 $ 300.00
Interim Rate Adjustment ("IRA") 2 $ 220.74
Total Customer Charge $ 520.74
Consumption Charge $ 0.13075 per Ccf
Notes: 1 - Per the 2013 West Texas Statement of Intent Amarillo, Lubbock, Dalhart, and Channing Settlement Agreement.
2 -2014 IRA- $76.67; 2015 IRA - $58.49; 2016 IRA - $85.58.
Upstream Transportation Cost Recovery: The customer ls responsible for all upstream transportation costs.
Retention Adjustment: Plus a quantity of gas equal to the Company's most recently calculated financial L&U percentage for the twelve months ended September multiplied by the gas received into Atmos Energy Corporation's West Texas Division for transportation to the customer.
Franchise Fee Adjustment: Plus an amount for franchise fees calculated In accordance wlth Rider FF. Rider FF is only applicable to customers inside the corporate limits of any incorporated municipality.
Tax Adjustment: Plus an amount for tax calculated ln accordance with Rider TAX.
The West Texas Division Amarillo, Lubbock, Dalhart, and Channing Interim Rate Adjustment applies to this schedule.
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: TRANSPORTATION SERVICE
APPLICABLE TO: AMARILLO SERVICE AREA - Inside City Limits (ICL)
EFFECTIVE DATE: I
Surcharges: Plus an amount for surcharges calculated in accordance with the applicable rider(s).
Miscellaneous Charges: Plus an amount for miscellaneous charges calculated in accordance with the applicable rider(s).
Conversions: Units may be converted from Ccf to Mcf or Mmbtu as necessary to comply with the underlying transportation agreement.
Imbalance Fees All fees charged to Customer under this Rate Schedule will be charged based on the quantities determined under the applicable Transportation Agreement and quantities will not be aggregated for any Customer with multiple Transportation Agreements for the purposes of such fees.
Monthly Imbalance Fees Customer shall pay Company a monthly imbalance fee at the end of each month as defined in the applicable Transportation Agreement,
Curtailment Overpull Fee Upon notification by Company of an event of curtailment or interruption of Customer's deliveries, Customer will, for each MMBtu delivered in excess of the stated level of curtailment or interruption, pay Company 200% of the "Index" price reported for the month of delivery in Inside FERC's Gas Market Report under the heading "West Texas Waha".
Replacement Index In the event the "Index" price reported for the month of delivery in Inside FERC's Gas Market Report under the heading "West Texas Waha" is no longer published, Company will calculate the applicable imbalance fees utilizing a daily price index recognized as authoritative by the natural gas industry and most closely approximating the applicable index.
Agreement A transportation agreement is required.
Notice Service hereunder and the rates for services provided are subject to the orders of regulatory bodies having jurisdiction and to the Company's Tariff for Gas Service.
Special Conditions In order to receive transportation service under this tariff, customer must have the type of meter, instrumentation, and communication required by Company. Customer must pay Company all costs associated with the acquisition and installatton of the required equipment.
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: RESIDENTIAL GAS SERVICE
APPLICABLE TO: LUBBOCK SERVICE AREA-Inside City Limits (ICL)
EFFECTIVE DATE: I
Availabillty
This schedule is applicable to general use by Residential customers for heating, cooking, refrigeration, water heating and other similar type uses. This schedule is not available for service to premises with an alternative supply of natural gas.
Monthly Rate
Customer Charge 1 $ 14.75
Interim Rate Adjustment ("IRA") 2 ·~
$ 6.41
Total Customer Charge $21.16
Consumption Charge $ 0.12449 per Ccf
The West Texas Division Gas Cost Adjustment Rider applies to this schedule.
The West Texas Division Weather Normalization Adjustment Rider applies to th ls schedule.
The West Texas Division Rlder TAX applies to this schedule.
The West Texas Division Rider FF applies to this schedule.
The West Texas Amarillo, Lubbock, Dalhart, and Channing Interim Rate Adjustment applies to this schedule.
Miscellaneous Charges: Plus an amount for miscellaneous charges calculated In accordance with the applicable rider(s).
Notes: 1 - Per the 2013 West Texas Statement of Intent Amarillo, Lubbock, Dalhart, and Channing Settlement Agreement.
2 - 2014 IRA - $2.32; 2015 IRA- $1.75; 2016 IRA- $2.34.
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: COMMERCIAL GAS SERVICE
APPLICABLE TO: LUBBOCK SERVICE AREA - Inside City Limits (ICL)
EFFECTIVE DATE: I Availability
This schedule is applicable to Commercial customers, including hospitals and churches, for heating, cooking, refrigeration, water heating and other similar type uses. This schedule is not avallable for service to premises with an alternative supply of natural gas.
Monthly Rate
Customer Charge 1 $ 33.00
Interim Rate Adjustment ("IRA") 2 $17.64
Total Customer Charge $ 50.64
Consumption Charge $ 0.11226 per Ccf
The West Texas Division Gas Cost Adjustment Rider applies to this schedule.
The West Texas Division Weather Normalization Adjustment Rider applies to this schedule.
The West Texas Division Rider TAX applies to thls schedule.
The West Texas Division Rider FF applies to this schedule.
The West Texas Amarillo, Lubbock, Dalhart, and Channing Interim Rate Adjustment applies to this schedule.
Miscellaneous Charges: Plus an amount for miscellaneous charges calculated in accordance with the applicable rlder{s).
Notes: 1 - Per the 2013 West Texas Statement of Intent Amarillo, Lubbock, Dalhart, and Channing Settlement Agreement.
2 - 2014 IRA- $6.38; 2015 IRA- $4.81; 2016 IRA - $6.45.
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: INDUSTRIAL GAS SERVICE
APPLICABLE TO: LUBBOCK SERVICE AREA - Inside City Limits (ICL)
EFFECTIVE DATE: I Availability
This schedule is applicable to the sales to any industrial or commercial customer whose predominant use of natural gas is other than space heating, cooking, water heating or other similar type uses. Service under this schedule is available to eliglble customers following execution of a contract specifying the maximum hourly load. This schedule is not available for service to premises with an alternative supply of natural gas.
Monthly Rate
Customer Charge 1 $ 300.00
Interim Rate Adjustment ("IRA") 2 $ 220.74
Total Customer Charge $ 520.74
Consumption Charge $ 0.08895 per Ccf
The West Texas Division Gas Cost Adjustment Rider applies to this schedule.
The West Texas Division Rider TAX applies to this schedule.
The West Texas Division Rider FF applies to this schedule.
The West Texas Division Amarillo, Lubbock, Dalhart, and Channing Interim Rate Adjustment applies to this schedule.
Miscellaneous Charges: Plus an amount for miscellaneous charges calculated in accordance with the applicable rider(s).
Notes: 1 - Per the 2013 West Texas Statement of Intent Amarillo, Lubbock, Dalhart, and Channing Settlement Agreement.
2 - 2014 IRA - $76.67; 2015 IRA - $58.49; 2016 IRA - $85.58.
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: PUBLIC AUTHORITY GAS SERVICE
APPLICABLE TO: LUBBOCK SERVICE AREA - Inside City Limits (ICL)
EFFECTIVE DATE: I Availability
This schedule is applicable to general use by Public Authority type customers, including public schools, for heating, cooking, refrigeratlon, water heating and other similar type uses. Thls schedule is not available for service to premises with an alternative supply of natural gas.
Monthly Rate
Customer Charge 1 $ 82.00
Interim Rate Adjustment ("IRA") 2 $ 51.72
Total Customer Charge $ 133.72
Consumption Charge $ 0.14512 per Ccf
The West Texas Division Gas Cost Adjustment Rider applies to this schedule.
The West Texas Division Weather Normalization Adjustment Rider applies to this schedule.
The West Texas Division Rider TAX applies to thls schedule.
The West Texas Division Rider FF applies to this schedule.
The West Texas Amarillo, Lubbock, Dalhart, and Channing Interim Rate Adjustment applles to this schedule.
Miscellaneous Charges: Plus an amount for miscellaneous charges calculated in accordance with the appllcable rider(s).
Notes: 1 - Per the 2013 West Texas Statement of Intent Amarillo, Lubbock, Dalhart, and Channing Settlement Agreement.
2 -2014 IRA - $18.96; 2015 IRA- $14.21; 2016 IRA- $18.55.
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: TRANSPORTATION SERVICE
APPLICABLE TO: LUBBOCK SERVICE AREA - Inside City Limits (ICL)
EFFECTIVE DATE: I
Application Applicable, in the event that Company has entered into a Transportation Agreement, to a customer directly connected to the Atmos Energy Corp., West Texas Division Distribution System for the transportation of all natural gas supplied by Customer or Customer's agent at one Point of Delivery for use in Customer's facility with an estimated annual usage greater than 100,000 Ccf per meter.
Type of Service Where service of the type desired by Customer is not already available at the Point of Delivery, additional charges and special contract arrangements between Company and Customer may be required prior to service being furnished.
Monthly Rate Customer's bill will be calculated by adding the following Customer and Ccf charges to the amounts and quantities due under the riders listed below:
Customer Charge per Meter 1 $ 300.00
Interim Rate Adjustment ("IRA") 2 $ 220.74
Total Customer Charge $ 520.74
Consumption Charge $ 0.08895 per Ccf
Notes: 1 - Per the 2013 West Texas Statement of Intent Amarillo, Lubbock, Dalhart, and Channing Settlement Agreement.
2 - 2014 IRA- $76.67; 2015 IRA- $58.49; 2016 IRA - $85.58.
Upstream Transportation Cost Recovery: The customer ls responsible for all upstream transportation costs.
Retention Adjustment: Plus a quantity of gas equal to the Company's most recently calculated financial L&U percentage for the twelve months ended September multiplied by the gas received into Atmos Energy Corporation's West Texas Division for transportation to the customer.
Franchise Fee Adjustment: Plus an amount for franchise fees calculated ln accordance with Rider FF. Rider FF is only applicable to customers inside the corporate limits of any incorporated municipality.
Tax Adjustment: Plus an amount for tax calculated in accordance with Rider TAX.
WEST TEXAS DIVISION ATMOS ENERGY CORPORATION
RATE SCHEDULE: TRANSPORTATION SERVICE ,.,
APPLICABLE TO: LUBBOCK SERVICE AREA - Inside City Limits (ICL)
EFFECTIVE DATE: I
The West Texas Division Amarillo, Lubbock, Dalhart, and Channing Interim Rate Adjustment applies to this schedule.
Surcharges: Plus an amount for surcharges calculated in accordance with the applicable rider(s).
Miscellaneous Charges: Plus an amount for miscellaneous charges calculated in accordance with the applicable rider(s).
Conversions: Units may be converted from Ccf to Mcf or Mmbtu as necessary to comply with the underlying transportation agreement
Imbalance Fees All fees charged to Customer under this Rate Schedule will be charged based on the quantities determined under the applicable Transportation Agreement and quantities will not be aggregated for any Customer with multiple Transportation Agreements for the purposes of such fees.
Monthly Imbalance Fees Customer shall pay Company a monthly imbalance fee at the end of each month as defined in the applicable Transportation Agreement,
Curtailment Overpull Fee Upon notification by Company of an event of curtailment or interruption of Customer's deliveries, Customer will, for each MMBtu delivered in excess of the stated level of curtailment or interruption, pay Company 200% of the "Index" price reported for the month of delivery in Inside FERC's Gas Market Report under the heading "West Texas Waha".
Replacement Index In the event the "Index" price reported for the month of delivery in Inside FERC's Gas Market Report under the heading "West Texas Waha" is no longer published, Company will calculate the applicable imbalance fees utllizing a daily price index recognized as authoritative by the natural gas industry and most closely approximating the applicable index.
Agreement A transportation agreement is required.
Notice Service hereunder and the rates for services provided are subject to the orders of regulatory bodies having jurisdiction and to the Company's Tariff for Gas Service.
Special Conditions In order to receive transportation service under this tariff, customer must have the type of meter, instrumentation, and communication required by Company. Customer must pay Company all costs associated with the acquisition and installation of the required equipment
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING GAS RELIABILITY INFRASTRUCTURE PROGRAM
ANNUAL EARNINGS MONITORING REPORT
Earnings Monitoring Report
ANNUAL EARNINGS MONITORING REPORT
OF
ATMOS ENERGY, WEST TEXAS DIVISION
TO THE CITIES OF AMARILLO, LUBBOCK, DALHART AND CHANNING
FOR THE PERIOD ENDING DECEMBER 31, 2016
FEBRUARY 24, 2017
Line
Number
1
2
3
4
5
6
7
8
9
10 11
12
13 14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
ATMOS ENERGY, WEST TEXAS DIVISION 2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
ANNUAL EARNINGS MONITORING REPORT FOR THE PERIOD ENDING DECEMBER 31, 2016
Reference Per
Description Per GUD 10174 (1) GUD 10174 (a) (b) (c)
Total Operating Revenues at Present Rates (2) $ 87,676,516
Operating Expenses:
Operation & Maintenance Expense Schedule A, Line 13 $ 33,010,577 Depreciation & Amortization Expense Schedule A, Line 17 19,202,631
Interest on Customer Deposits Schedule A, Line 19 6,115 Taxes Other Than Income Taxes Schedule A, Line 15 4,853,908
Total Operating Expenses Before Federal Income Taxes Sum of Line 4 - Line 7 $ 57,073,231
Operating Income Before Federal Income Taxes Line 1- Line 9 $ 30,603,285
Less: Federal Income Taxes Schedule A, Line 25 $ 8,826,709
Operating Income After Taxes (3) Line 11- Line 13 $ 21,776,576
Allowed Return: Rate Base Schedule A, Line 21 $ 271,590,560
Allowed Cost of Capital Schedule A, Line 22 8.57%
Calculated Allowed Return Line 19 x Line 20 $ 23,270,937
Net Revenue (Deficiency) /Sufficiency Line 15 - Line 21
Allowed Rate of Return - Per GUD 10170
Actual Rate of Return - Twelve Month Test Period 2016 Line 15 / Line 19
Note:
1. GUD 10174 references noted in Column (b) are from the Examiner's Schedules.
2. Please see GUD 10174 Final Order Exhibit B - Revenues at Proposed Rates.
3. Column (d) is the increase/decrease between Columns (c) and (e).
Increase I Per Books (Decrease) at 12/31/2016
(d) (e)
$ 25,205,639 $ 112,882,155
$ 8,653,694 $ 41,664,271
5,565,349 24,767,980 (685) 5,430
2,391,539 7,245,447
$ 16,609,897 $ 73,683,129
$ 8,595,742 $ 39,199,027
$ (345,855) $ 8,480,854
$ 8,941,597 $ 30,718,173
$ 476,688,397
8.57%
$ 40,844,519
$ (10,126,346)
8.57%
6.44%
EMR
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
ANNUAL EARNINGS MONITORING REPORT
FOR THE PERIOD ENDING DECEMBER 31, 2016
FEDERAL INCOME TAX SCHEDULE AT END OF REPORTING PERIOD
Line
No. Description Adjusted Amount Reference
1 TotalRevenues
2
3
4 Deduct:
(a)
5 Operation and Maintenance Expenses
6 Depreciation and Amortization Expense
7 Taxes Other Than Income Taxes
8 Interest on Customers' Deposits and Advances
9 Interest Expense
10 Total Deducts
11
12 Book Taxable Income
13
14 Tax Rate
15 16 Total Federal Income Taxes
17
18 Note:
(b)
112,882,155 EMR, Col (e), Ln 1 -'-~~~~~~~'"---'-~ s
s 41,664,271 EMR, Col (e), Ln 4
24,767,980 EMR, Col (e), Ln 5
7,245,447 EMR, Col (e), Ln 7
5,430 EMR, Col (e), Ln 6
14,968,016 See Note 1
(c)
S 88,651,144 Sum of Lines 4 through 9
S 24,231,011 Line 1 - Line 10
35% Statutory Tax Rate
$ 8,480,854 Line 12 times Line 14
19 1. This amount is calculated by applying the weighted cost of debt to the total rate base (Schedule A.1-1, Column (e), Line 1
20 times EMR, Column {e), Line 19).
Schedule A.1
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
ANNUAL EARNINGS MONITORING REPORT
Line
No.
Long-Term Debt
Common Equity
Description {a)
1 2 3 4
5
6
Total (Line 1 + Line 3)
7 Notes:
FOR THE PERIOD ENDING DECEMBER 31, 2016
WEIGHTED AVERAGE COST OF CAPITAL
Balance Percent of Total (b) (c)
$ 230,288,114 48.31%
246,400,283 51.69%
-$ 476,688,397 100%
8 1. Column (c) is the approved Capital Structure from GUO 10170.
9 2. Column (d) are the approved rates of return from GUO 10170.
Cost (d)
6.50%
10.50%
Weighted Cost
{Col. (c) * Col. (d)]
(e)
3.14%
5.43%
8.57%
Schedule A.1-1
Line
Number
1
2
3
4
5
6
7
8
9
10
11
12
13 14
15
16
17
18
19
20
21
22
23
24
ATMOS ENERGY, WEST TEXAS DIVISION 2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
ANNUAL EARNINGS MONITORING REPORT
FOR THE PERIOD ENDING DECEMBER 31, 2016 TOTAL RATE BASE
Per Book
Description Reference (1) Reference (2) Amount
(a) (b) (c) (d)
Net Plant:
Utility Plant in Service 101 4 $ 718,546,770
Accumulated Depreciation and Amortization 108/111 4 (157,261,209)
Total Net Plant (Line 2 +Line 3) $ 561,285,560
Additions:
Gas Stored - Current 164.1 5 $ 7,817,893
Materials and Supplies 154/163 5 71,285
Prepayments 165 5 2,503,623
Other 3 -Total Additions (Sum Line 7 through Line 10) $ 10,392,801
Deductions:
Customer Deposits 235 $ 3,788,583
Customer Advances for Construction 252 865,799
Injuries and Damages Reserve 228.2 483,535
Accumulated Deferred Income Taxes 190/282/283 6 109,148,840
Rate Base Adjustments 7
Total Deductions (Sum Line 14 through Line 18) $ 114,286,759
Total Cash Working Capital 8 $ -
Total Rate Base (Ln 4 + Ln 11- Ln 19 + Ln 21) $ 457,391,603
Adjusted
Adjustment Amount (e) (f)
$ 6,844,985 $ 725,391,754
92,474 (157,168, 735)
$ 6,937,459 $ 568,223,019
$ (1,687,527) $ 6,130,366
4,365 75,650
(451,145) 2,052,478
$ (2,134,307) $ 8,258,494
$ - $ 3,788,583 - 865,799
- 483,535
(17,401,559) 91,747,282
382,946 382,946
$ (17,018,612) $ 97,268,146
$ (2,524,970) $ (2,524,970)
$ 19,296,794 $ 476,688,397
Schedule B
Line
Number
25 Notes:
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
ANNUAL EARNINGS MONITORING REPORT FOR THE PERIOD ENDING DECEMBER 31, 2016
TOTAL RATE BASE
Description Reference (1) Reference (2) Per Book
Amount (a) (b) (c) (d)
26 1. Column (b) references the FERC Account Numbers associated with the amounts included in Column (d). 27 2. The information !listed in Column (c) refers to the footnote explanation of the adjustment shown in Column (e). 28 3. Line 10 is an input area for adjustments.
Adjustment (e)
29 4. Column (e) includes adjustments to include the 8.209 regulatory asset and remove SSU projects disallowed in prior rate filings.
30 5. Adjusted from period ending to 13 month average.
31 6. Adjusted to remove the NOL Carryforward - Non Reg and NOL Carryforward - Other.
32 7. Adjusted to include Rate Base adjustments recognized in the 2013 WTX Statement of Intent and prior dockets.
33 8. Adjusted to include Cash Working Capital adjustments per GUD 10174.
Adjusted
Amount (f)
Schedule B
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION 2016 ANNUAL GAS RELIABILITY INFRASTRUCTURE PROGRAM RATE
ADJUSTMENT FOR THE INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART, AND CHANNING
Annual Earnings Monitoring Report Attestation
I certify that I am the responsible official of Atmos Energy Corporation, West Texas Division; that I have examined the foregoing report; that to the best of my knowledge, information, and belief, all statements of fact contained in the said report are true and the said report is a correct statement of the business and affairs of the above-named respondent in respect to each and every matter set forth therein during the period from January 1, 2016 to December 31, 2016 inclusive.
I m1derstand until the issuance of a final order or decision by a regulatory authority in a rate case that is filed after the implementation of a tariff or rate schedule under this section, ail amounts collected under the tariff or rate schedule before the filing of the rate case are subject to refund.
SWORN TO AND SUBSCRIBED before me on this the {~~day of February 2017.
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
GAS RELIABILITY INFRASTRUCTURE PROGRAM
INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
Project Reports
DESCRIPTION
WTX DIRECT DIVISION
WTX GENERAL OFFICE
SSU - GENERAL OFFICE
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
FOR THE TWELVE MONTH PERIOD ENDING DECEMBER 31, 2016
SUMMARY OF ASSET ACTIVITY
RETIREMENTS NET ADDITIONS & TRANSFERS CHANGE ADJUSTMENTS
$ 78,471,579 $ (12,005,088) $ 66,466,492 $ 1,118,986
2,135,873 (224,981) 1,910,892 33,517
1,334,384 (2,861,502) (1,527,119) 548,400
SSU -CUSTOMER SUPPORT 403,344 (2,635,107) (2,231, 762) (71,714)
TOTAL $ 82,345,181 $ (17,726,678) $ 64,618,503 $ 1,629,190
REQUESTED
CHANGE
$ 67,585,478
1,944,409
(978,718)
(2,303,476)
$ 66,247,693
PROJECT SUMMARY
LINE ALLOCATED NO. PROJECT NUMBER COST (11 COST
95.42%
ATMOS ENfRGYCOR.PORATION, WEST TEXAS DlVl:SION
INTERIM CO.ST RECOVCMY AND RATE ADJUSTMEMT RE.PORT PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDJCATED TO PUBLIC USE IN CALENDAR VEAR 2016 (2)
CUSTOMERS BENEFITED
WEST TEXAS GENERAL OFFrCE ADDITIONS PER BOOKS· DMS{O{t/ 010
1 030.38850 8,032 7,664
2 030.38978 146,576 139,857
3 030.39001 201,548 192,309
4 030,3911:3 1.265 1,207
5 030.39125 1,657 1,681
6 030.39240 2,902 2,769
7 000.39241 62,391 78,614
6 0'30.39246 B,872 8,465
9 030,39280 17.295 16,502
10 030.39417 26,332 25,125
11 030.39520 336 321
12 030.39521 20,200 26,915
13 030.39522 7,082 6,757
14 030.39600 57,791 55,141
15 030.39626 56,793 "6.096
16 030.39629 2,"67 2.449
17 030.39672 15,649 14.932
18 030.39609 5,341 5,096
19 030.39714 4,938 4,712
20 030.39758 12,911 12,319
21 030.39768 105,236 100,411
22 030.39789 30,071 26,693
23 030_39792 7,593 7,245
24 030_39603 36,557 34,682
25 030_39829 22,769 21,726
26 030.39898 14,408 13,745
27 030.39899 4,117 3,928
2B OJ0.39961 1,731 1,652
29 030.40032 15.180 14.404
30 030.40034 19,508 1B,614
31 030.40206 10.056 9,595
32 030.40211 27,950 26,669
33 030.40282 12,265 11,703
34 030.40401 26,980 25,744
35 030.40409 3,764 3,592
36 030.40587 14.513 13,840
37 030.40716 104,065 175,626
36 030.40717 50,445 5o.765
39 030.40a83 10,891 10,392
40 030.41099 21.520 20,541
41 030.41100 18.oa5 17.256
42 030.41153 47,977 45,778
43 030.41211 30,112 28.732
44 030.41239 40,081 38,243
45 030.41241 55,564 53,016
46 030.41242 30,817 29,404
47 030.41258 25,735 24,555
48 030.41340 102,1as 97,51J1
49 030.41525 31,895 30,432
50 030.41627 a,968 8,557
51 030.41924 70,424 57,195
52 030.41928 09.585 85.478
PURCHASE MISCELLANEOUS EQUIPMENT FOR USE BY WEST TEXAS DIVISION EMPLOYEES MISC EQUIPMENT FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCflASE TRIMBLE UNITS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE COMPUTER HARDWARE FOR USE !!Y WEST TEXAS DIVISION EMPLOYEES REPLACE CAMERA SYSTEM FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 6 REPLACEMENT PERSONAL COMPUTERS AND MONITORS AND 1 l.Af>TOP FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 16 LAPTOP/PCISURFACE PRO'S FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE REPLACEMENT MOTS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 3 SURFACE PROS FOR USE BYWESTTEXAS DIVISION EMPLOYEES PURCHASE 16 LAPTOPIPCISURFACE PRO'S FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE PROJECTOR FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE CONFERENCE ROOM UPGRADE FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE CONFERENCE ROOM UPGRADE FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 27 l.Af>TOPs FOR USE BY WEST TEXAS DMSION EMPLOYEES PURCHASE 12 MOT'S FOR USE BY WEST TEXAS OIVISIOl-I EMPLOYEES PURCfJASE ONE COMPUTER FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 2 ETHANE DETECTORS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE LAPTOPS FOR USE BY WEST TEXAS D!VISION EMPLOYEES PURCHASE UPGRADE FOR MEETING ROOM AV FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE AV SYSTEM UPGRADE FDR USE BY WEST TEXAS DIVISION EMPLOYEES
PURCHASE UPGRAD3 AND EXPANSION OF SHARED STORAGE DATABASE FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE REPLACEMEl>IT OF TOLL TAG READERS FOR USE BY WESTTEXAS DIVISION EMPLOYEES PURCHASE UPGRADE OF ELTIMA FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE UPGRADE OF AV IN LUBBOCK TRAINING ROOMS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 3 TVS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE COMPUTERS FOR USE BY WEST TEXAS DMSiON EMPLOYEES PURCHASE RENEWAL OF ECAO SOFTWARE AND NEW LICENSES FOR USE 6Y WEST TEXAS DIVISION EMPLOYEES PURCHASE TOOLBOX FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE DOOR LOCKS AND COMMUNICATION PANEL FDR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE UPGRADE TO AV EQUIPMENT FOR USE BY WEST TEXAS OMS ION EMPLOYEES PURCHASE SWITCH REPLACEMENT FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE DMVPN ROUTER UPGRADE FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURcflASE 4 NEW l.Af>TOPS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE CAMERA SYSTEM UPGRADE IN HEREFORD FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 1 LAPTOP FOR USE BY WEST TEXAS DIVISION EMPLOYEES
PURCHASE OF COATING THICKNESS AND SURFACE FINISH GAUGE KIT, WALL THICKNESS GAUGE KIT, AND PIPE THREADERS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE THREE CNG TRAILERS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE25 CALIBRATION STATIONS FDR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE NEW SERVER FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 6 WMR PROGRAMMERS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 10 DIGITAL GAUGES FOR USE BY WE.ST TEXAS DIVISION EMPLOYEES PURCHASE 1 PORTABLE PROVER FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 16 ERX PRESSURE RECORDER FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE ROOM UPGRADES IN PERMIAN BASIN FOR USE !!Y WEST TEXAS DllllSION EMPLOYEES PURCHASE UPGRADE FOR VMWARE SOFTWARE FOR USE BY WESTTEXAS DIVISION EMPLOYEES PURCHASE VIRTUAL DESKTOP SOFTWARE FOR USE !IY WEST TEXAS DIVISION EMPLOYEES PURCHASE LASE.RF!CHE US:ER LICENSE FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE LAPTOPS AND MONITORS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 16 CGIS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE SMART !!OARD FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 4 SURFACE PRO WITH DOCKS AND 13 MOTS FOR USE BY WEST TEXAS DIVISION EMPLOYEES
PURCHASE 41 lAPTDPS AND DOCKING STATIONS, 107 MONITORS AND 21 PCS FOR USE BY WEST TEXAS DIVISION EMPLOYEES
WIXAddilions Page lof98
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MiX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL· MIX
ALL- MIX
ALL- MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
LOCATION PURPOSE OF PROJECT
030 TEXAS DIVISION EQUIPMENT
030 TEXAS DIVISION EQUIPMENT INFORMATION
030 TEXAS DIVISION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DiVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
030 TEXAS DIVISION EQUIPMENT INFORMATION
030 TEXAS DIVISION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY
INfORMAllON 030 TEXAS OIVJSION TECHNOLOGY
INFORMATION 000 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS D!VISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
030 TEXAS DIVISION EQUIPMENT INFORMATION
030 TEXAS DIVISION TECHMOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY
030TEXAS DIVISION EQUIPMENT
030 TEXAS DIVtSION EQUIPMENT
030 TEXAS DIVISION EQUIPMENT INFORMATION
030 TEXAS DIVISION TECHNOLOGY
030 TEXAS DIVISION EQUIPMENT
030 TEXAS DIVISION EQUIPMENT
030 lEXAS DIVISION EQUIPMENT
030 TEXAS DIVISION EQUIPMENT INFORMATIDN
030 TEXAS DIVJSION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECflNOLOGY INFORMATION
030 TEXAS DMSION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY INFORMATION
030 TEXAS DIVISION TECHNOLOGY
030 TEXAS DIVISION EQUIPMENT INFORMATION
030 TEXAS DIVISION TECHNOLOGY INFORMATION
030 TEXAS DIVISION lECHNOLOGY
INFORMATION 030 TEXAS DIVISION TECHNOLOGY
DATE PLACED IN GAS PLANT IN
SERVICE
AUGUST-2016
sEPTEMBER-2016
AUGUST-2016
AUGUST - 2016
AUGUST - 2016
AUGUST - 2016
AUGUST - 2016
AUGUST - '2016
SEPTEMBER - 2016
AUGUST - 2016
AUGUST - 2016
AUGUST - 2016
AUGUST - 2016
AUGUST - 2016
AUGUST - 2016
AUGUST - 2016
AUGUST • 2016
AUGUST - 2016
AUGUST -2016
AUGUST -2016
AUGUST - 2016
DECEMBER - 2016
AUGUST - 2016
AUGUST - 2016
SEPTEMBER • 2016
AUGUST - 2016
AUGUST - 2016
AUGUST - 2016
AUGUST - 2016
AUGUST-2016
OE:CEMBER·2010
DECEMBER-2016
AUGUST - 2016
SEPTEMBER - 2016
AUGUST - 2016
SEPIEMBER - 20"'16
NOVEMBER - 2016
OCTOBER • 2016
OCTO!IER - 2016
DECEMBER· 2016
DECEMBER • 2016
DECEMBER - 2016
DECEMBER~ 2016
DECEMBER -2016
DECEMBER· 2016
DECEMBER - 2016
DECEMBER ~ 20116
DECEMBER -2016
DECEMBER - 2016
OCTOBER-2016
DECEMBER - 2016
DECEMBER· 2016
I
LINE No.
53
54
~ 56 ,____ 57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
n 73 74
75
75
77
78
79
80
81
82
83
84
95
as
PROJECT NUMBER COST(11
030.41938 368,959
TOTAL WEST TEXAS GENERAL OFFICE -
DIVISION 010 ADDITIONS
[email protected]% (LN.1 -LN. 53) 2,238,4'95
ALLOCATED COST
352.04~
2,135,873
ATMOS ENERGY COFIPORATION, WESTTEXA:S DlVl:S.ION INTERIM CO.ST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPoRT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TD CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 [2} BENEfm;o
PURCHASE 92 REPLACEMENT MOT'S FOR USE BV WEST TEXAS DIVISION EMPLOYEES ALL-MIX
WEST TE>rAS - ALL OTHER DIVISIONS ADDITIOl/S PER BOOKS
000.166ti2 1.356
030.16711 799
030.17683 1,840
030.18606 4,684
030.1863'; 2,507
030.19514 13.2621
030.19697 (1251
030.19813 1351)
030.19817 882
030.19921 (BBi
030.19982 958
O'l0.20064 933
030.20066 257
030.20088 21,565
030.20096 220
030.28651 9,851
0'30.30074 10,260
030,33077 4.412
030.33080 {580
030.33143 67,094
030.33152 7
030.33196 r1,594l
030.35029 44,834
030.35313 33,376
031).35316 6.47a
030.35318 3,283
030.35325 33.004
030.35330 104.321
030.35333 1,712
AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCK DIAMETER, ANODES, METERS, REGULATORS AND METER
1,356 LOOl="S AMARl\.\.O OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVlCE l.INES. PIPE 5FEETTO 99FEETOFLESSTHAN 8 INCH DIAMETER. ANODES. METERS, REGU\.ATORS AND METER
799 LOOPS AMARl\.LO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVjCE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES. METERS, REGULATORS ANO METER
1,840 LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEETT099FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGLILATO:RS AND METER
4.684 LOOPS PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS TKAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER
2,507 LOOPS PURCHASE 50 FREEWAVE UNITS FOR USE BY WEST TEXAS
(3,262l DIVISION EMPLOYEES LUBBOCK OPERATIONS BLANKET FOR NEW SERVICE LINES,
1125) METERS AND REGULATORS DUE TO CUSTOMER GROWTH MIDLAND/ODESSA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS,
[3o1l REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIP!' 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER. ANODES. METERS. REGULATORS AND METER
882 I.OOPS MIDLAND/ODESSA OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS ANO REGULATORS DUE TO CUSTOMER GROWTK
(88) LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVlCE UNES. PIPE 5 FEET TO 99 FEET OF LESS THAN 9 INCH DIAMETER. ANODES. METERS. REGULATORS AND METER
958 LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVlCELINEs, PIPES FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES. METERS, REGULATORS AND METER
933 LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKs: SERVICE LINES. PIPE 5 FEET TO "" FEET OF LESS THAN a INCH DIAMETER, ANODES. METERS. REGULATORS AND METER
257 LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER
21,565 LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER. ANODES, METERS. REGULATORS AND METER
220 LOOPS INSTALL 1 RECTIFIER AND 1 DEEf'WELL BED, RETIRE 2
9,851 RECTIFIERS DUE TO SYSTEM INTEGRITY 10,260 REBUILD CPR STAT~ON DUE TO SYSTEM IMPROVEMENTS
4,412 INSTALL IP COMMUNICATION DUE TO SYSTEM IMPROVEMENTS
(5801 INSTALL IP COMMUNICATJONS DUE TO SYSTEM IMPROVEMENTS
CONSTRUCT NEW BUILDING FOR LUBBOCK OPERATIONS AND 67,094 WEST TEXAS DIVISION DUE TO BUILDINGILAND IMPROVEMENTS
7 REPAIR AND REPLACE RECTIFIER DUE TO SYSTEM INTEGRITY
11,6941
44.834
33.378
6.478
3.283
33,004
104,321
1,712
INSTALL 4BO FEET OF 6 INCH POLY MAIN DUE TO SYsTEM IMPROVEMENTS LUBBOCK OPERATIONS BLANKET TO COVER GROWTH TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 Fl'ET TO 99 FEET OFLESS THAN 8 INCH DIAMETER. ANoDEs. METERS, REGULATORS AND METER LOOPS LITTLEFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEETTOG9 FEET OF LESS THAN8 INC!l DIAMETER, ANODES, METERS. REGULATORS AND METER LOOPS AMARlll.O OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET T099 FEET OF LESS THAN 8 INCH DIAMETER, ANODCS, METERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEEOT OF LESS THAN a INCH DIAMETER, ANODES. METERS. REGULATORS AND METER LOOPS
WTXAddUlons Pagf! 2 of9.B
ALL· MIX
ALL- MIX
ALL-MIX
AL\.-MIX
AL\.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX All.-MIX
ALL- MIX
ALL-MIX
ALL-MIX
0
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
OATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE INFORMATION
030 TEXAS DIVISION TECHNOLOGY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRtlY OCTOBER ~ 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEM!IER • 2016
030 TEXAS DIVISION SYSTEM INTEGR!lY SEPTEMBER - 2016 INFORMATION
030 TEXAS DIVISION TECHNOLOGY SEPTEMBER -2016
030 TEXAS DIVISION GROWTH AUGUST · 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER~ 201'6
030 TEXAS DMSION SYSTEM INTEGRITY OCTOBER -2016
030 TEXAS DIVISION GROWTK AUGUST - 2016
030 TEXAS DMSION SYSTEM INTEGllf!Y SEPTEMBER · 2016
oao TS(AS DlVlSION SYSTEM INTEGRITY SEPTEMBER • 2016
030 TEXAS DIVISiON SYSTCM INTEGRITY SEPTEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGR1TY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST "2016 030 TEXAS DIVISION SYSTEM IMPROVEMENTS FEBRUARY - 2.010
030 TEXAS DIVISION SYSTEM IMPROVEMENTS JANUARY -2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION STRUCTURES SEPTEMBER - 2016
030 TEXAS DiVJSION SYSTEM INTEGRf!Y DECEMBER" 2016
030TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION GROWTH DECEMBER • 2016
• 030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2016
OBO TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DMSION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
LINE NO, PROJECT NUMBER. COST(1}
B7 030.35340 529,954
BB 030.35341 13,263
89 030.35344 62,689
90 030.35346 1,336
91 030.35347 9,056
92 030.35349 24.216
93 030.35355 20,978
94 030.30359 29,612
95 030.35360 5,572
96 030.35361 57,810
97 030.35362 13,825
98 030.35363 653,706
99 030,35364 50.123
100 030.35365 1.175,483
101 030.35386 20,674
102 030.35367 11,389
103 030,353138 19,687
104 030.35370 11,129
105 030.35371 48,230
106 030.35372 12.796
107 030.35373 27,457
108 030.35374 31,005
109 030.35375 392,3ot1
110 030.35370 14,780
111 030.35377 37
112 030.35300 26,45•
113 0'30,35362 363,067
114 000.35386 [225
115 030.35387 [52)
115 030.3:5388 (4561
117 030.30391 (947)
ALLOCATED COST
529.954
13,263
62,689
1,Jl6
9,056
Ai'MOS ENERGYCDRPORAT!DN. WEST TEXAS. DIVIS.ION INTERIM COST RECOVERY AND MT£ ADJUSTMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED To CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 {2) BENEFITED
AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS ALL-MIX HEREFORD OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FIOET TO 99 FE!Ol OF LESS THAN B INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS ALL-MIX PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS ALL-MIX BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS ALL-MIX
LITTLEFIELD OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTH All-MIX
l~~~~~b~~~~~~~~~:~~~~~ED~~:~A~~~~ ~~~~~~~9 24.216
20,978
29,612
o.572
57,810
13,625
653,708
50,123
1.175,483
20,674
11,309
19.687
11,129
46,230
12.796
27,457
31,005
392,341
14,780
37
26,459
3B3.0S7
(225)
152)
(4561
(947)
FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
PLAlNVIEW OPERATIONS BLANKET FOR NEW SERVICE !.INES, M<OTERS AND REGLJLATORS DUE TO CLJSTDMER GROWTH
AMARILLO OPERATIONS BLANKET TO COVER GROWTH TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, MIOTERS, REGULATORS AND METER LOOPS PAMPA OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTH
LU!IBOCK OPERATIONS BLANKET TD COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER HEREFORD OPERATIONS BLANKET TO COVER GROWTH TASKS: SERV!CE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
PERMIAN BASIN OPERATiONS BLANKET TD COVER GROWTH TASKS: SERVICE LINES, PIPE 5 FEETTO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS BIG SPRING OPERATIONS BLANKET TO COVER GROWTH TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
LUBBOCK OPERATIONS BLA!;KETTO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD99 FEET OF LESS THAN 8 INCH DIAMETER. ANODES, METERS. REGULATORS AND METER LOOPS SEMINOLEIBROWNFIELD OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTH LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PAMPAOPERATJONS BLANKET FOR NEW SERVJCE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTfl LITTLEFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LITTLEFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
AMARILLO OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND REGULATORS DUE TD CUSTOMER GROWTH PLAINVIEW OPERATIONS BLANKET TO COVER REPLACEIR<TIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEIOTOF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET FOR NEW SER~ICE LINES, METE.RS ANO REGUtATORS DUE TO CUSTOMER GROWTH PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEETTO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS PAMPA OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTH LUBBOCK OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTH AMARILLO OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 09 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS !ILANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER. ANODES, METERS. REGULATORS AND METER l,.OOf'S PAMPA OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEETTO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PAMPA OPERATIONS BLANKET TO COVER REPlACEJRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS HEREFORD OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS
W1XAdditi01'S Jlage3 of9B
All-MIX
ALL-MIX
AL!.-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
All.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
All-MJX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL· MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DAlE PLACED lN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
O:l-0 TEXAS DIVISION SYSTEM INTEGRl'!Y DECEMBER-2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION SYSTEM 11>.'TEGRtlY DECEMBER~ 201-6
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTI-1 DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRl!Y OECEMBER - 2016
000 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DE;CLOMB!OR - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER- 2016
030 TEXAS DlVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION SYSTEM IN1EGRITY DECEMBER~ 2016
030 TEXAS DIVISION GROWTH AUGUST - 2015
030 TEXAS DIVISlON GROWTH OECEMBER-2015
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2015
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER -2015
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
LINE ALLOCATED NO. PROJECT NUMBER COST[11 COST
118 030.35392 30.113 30,113
119 030.35393 15,298 15,298
120 030.35394 168,429 168,429
121 030.35395 123) [23f
122 030,35397 28.849 2a.B49
123 030.35401 19,s:m 19,'63B
124 030.3:5403 (4,347) (4,347)
125 030.35404 MS5 6,556
126 030.35405 6,231 6,231
127 030.35406 4,950 4,960
126 030.35410 471,116 471,116
129 030.35415 15611 (561)
130 030.35422 957 957
131 030.35430 (111 (111
132 030.354"2 1188) {188)
133 030.35438 8,904 8.904
134 030,35440 160,190 160,190
135 030.35445 1,761 1,761
136 030.35446 (799) 17991
137 030.35447 3,785 3,785
138 030.35453 40,478 40,478
1:3S 030.35454 53,740 53,740
140 030.35456 22,925 22,925
141 030.35457 78,883 78,683
142 030.35450 31,936 31,9JCJ
143 Oo0.35459 105.166 105,166
144 030.35460 51,251 61,251
145 030.354B1 22,720 22,720
146 030.35463 17,698 17,698
ATMOS ENERGY CORPORATION, WEST TEXAS DEVISION INTERIM COSTRECOVERY ANO MTE ADJUSTMENHEPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
HEREFORD OPERATIONS BLANKEOTTO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET Of LESS THAN S INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PERMIAN BASIN OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTH
PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE UNES, PIPE 5 FEET TD99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
HEREFORD OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTH AMARILLO OPERATIONS BLANKET TD COVER GROWTH TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE S FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS BIG SPRING OPERATIONS BLANKET TD COVER REP!.ACEIRETIRE TASKS: SERlllCE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET FOR NEW SERVICE UNES, METERS AND REGULATORS DUE TD CUSTOMER GROWTH SEMINOLE;IBROWNFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF l.ESS THAN 8 INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS SEMINOLE/BROWNFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVlCE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN S INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEETT099 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN S INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPES FEET TO 99 FEET OF LESS THAN8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER t..OOPS PERMIAN BASIN OPERATlONS BLANKET TD COVER REPLACE/RETIRE TASKS: SERVlCE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS; SERVICE LINES, PIPE 5 FEET TO 99 FEET OF l.ESS THAN 8 INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BlANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS TllAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LITTLEFIELD OPERATIONS BLANKET TO COVER REPLACEIRETJRE TASKS: SERVICE UNES, PIPE fi FEET TO 9.9 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPES FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PLAINVIEW OPERATJONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEl'T Of 1.ESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVlCE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DfAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVfCE LINES, PIPE 5 FEETTO 99 FEET Of LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
HEREFORD OPERATIONS Bl.ANKET TD COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS TliAN a INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS BIG SPRING OPERATIONS llLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS. REGULATORS AND METER LOOPS PLAlNV~EW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERV!CE LINES, PIPE 5-FEETTO 99FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND MET~"R LOOPS SEMINOlEIBROWNFIEl.O OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
wntAddttions P.age4 of98
CUSTOMERS BENEFITED
ALL-MIX
AL!.-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
All-MIX
ALL-MIX
ALL-MJX
ALL· MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
Al.L-MIX
ALL-MIX
DATE ........ CE.DIN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
O::lll TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-201£
030 TEXAS DIVISION GROWTH DECEMBER· 2015
030 TEXAS OIVISIDN SYSTEM INTEGRITY DECEMBER • 2016
030 TEXAS DIVISION GROWTH SEPTEMBER - 2016
030 TEXAS DIVISION GROWTfl DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 201B
030TEXAS DIVISION SYSTEM INTEGRITY DECEMBER • 2.016
030 TEXAS DIVISION GROWTH DECEMBER - 2.016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DIVlslON SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2.016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER ~ 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2018
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMSER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DIVISlON SYSTEM INTEGRflY DECEMBER - 2016
030TEXAs DIVISION SYSTEM INTEGRITY DECEMBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER M 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DMSION SYSTEM INTEGRliY DECEMBER - 2015
LINE ALLOCATED NO. PROJECT NUMBER COST{11 COST
147 030.35464 727 727
148 030.35465 78.700 78,700
149 030.35467 58,003 58,003
150 030.35473 582,129 582,129
151 030,35479 51,073 51,073
152 030.35483 83,142 83,142
153 030.35498 6,456 6,456
154 030.35500 !6551 (655)
105 030.31>601 197.061 197.061
156 030.35505 20,347 20,347
157 030.35517 1740) f740'
166 030.35523 82,170 62.170
159 030.355.a4 284.472 284.472
160 030.35535 51,666 51.666
161 030.35537 21,234 21.234
162 030.35538 19,168 19,1~
163 0:30,35540 >0.040 50,040
154 030.35541 14,960 14,960
165 030.35544 729,195 729,195
16£ 030,35546 22,781 22.781
167 030.35547 22,634 22,634
168 030.35549 3,947 3,947
169 030.35551 28,446 28,446
170 030.35552 99,919 99,919
171 030.35553 [1.066] (1.066)
172 030_35554 509,033 509,033
173 030.35558 15,392 15,392
174 030.35567 16,403 16,403
176 030,3551!8 2,926 2.926
ATMOS ltNERGY CORPORATION, WEST TEXAS DIVISION INTERIM COST RECOVERY ANO RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TD PUBLIC USE IN CALENDAR Vl'AR 2016121
P!-AINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERV1CE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 00 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 l="EET JO 99 i=EET OF LESS THAN 8 INCH DIAMETER, ANODES, MEl'~RS, REGULATORS AND METER LOOPS PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 6 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS. REGULATORS AND METER LOOPS PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS. REGULATORS AND METER LOOPS AMARILLO OPERATlONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LE.SS THAN 8 lNCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TD COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEH OF LESS THAN 8 INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS LITTLEFIELD OPERATIONS Bt.ANKET TO COVER REPLACE/RETIRE TASKS: SERVlCEUNES, P!PE5 FEET TO 99 FEET OF LESS TflANB INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS~ SERVICEUNES, PIPE.5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOFS AMARILLO OPERATIONS BLANKET TO COVER GROWTH TASKS: SERVICE LINES, PIPE 6 FEET TO 99 FEET Of LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
LUBl!OCK OPERATIONS BLANKET TO COVER GROWTH TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS
LITTLEFIELD DPERATIONS BLANKET TO COVER GROWTH TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
PLAINVlEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERV~CE LINES, PlPE 5 FEET TO 99 FE:ETOF lESSTHAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEETTO 99 FEET OFLESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PAMPA OPERATIONS BLANKET FOR NEW SERViCE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTH PERMIAN BASIN OPERATIONS BLANKET TO COVER GROWTH TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS BIG SPRING OPERATIONS BLANKET TO COVER GROWTHTASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
SEMINOLE/BROWNFIELD OPERATIONS 6LANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET T099 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PAMPA OPERATIONS BLANKET TO COVER REPl-ACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER GROWTH TASKS: SERVICE LINES, PIPE 5 FEET TO S9 FEET OF LESS THAN 8 INCH DIAMETER. ANODES, METERS. REGULATORS AND METER LOOPS
AMARI LLD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO :99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LU!l!IOCK OPERATIONS BLANKET TO COVERGROWTH TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THANS INOH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
LUBBOCK OPERATIONS BLANKET TO COVER GROWTH TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
PERMIAN BASIN OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTH
AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
WTX Additions Page5 of:98
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALl..-MIX
All-MIX
ALL-MIX
ALl.·MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL- MIX
ALL-MIX
UATE PLA,Ct::D IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS OIVlSION SYSTEM INTEGRITY DECEMBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER • 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER~ 2016
030 TEXAS DIVISiON SYSTEM INTEGRITY DECEMBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DMSION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DMSION SYSTEM iMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER- 2016
I 030TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DlVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH DECEMBER- 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISIDN GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH DECEMBER- 2018
030 TEXAS D!VlSION GROWTH DECEMBER- 2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030TEXAS DIVISION GROWTH DECEMBER • 2{)16
030 TEXAS DrvtS!ON SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECl=MBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH O!:;CEMBER • 2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DMSION SYSTEM INTEGRITY DECEMBER • 2016
LINE No. PROJECT NUMBER COST(1)
176 030.35570 lltl
177 030.35574 21!0
178 030.35575 43,602
179 030.35578 11,184
180 030.35583 15,672
181 030.35589 1.653
162 030.35590 10,033
183 030.35594 94,480
164 030.30597 (2
185 030,35599 16,520
186 030.35601 {1,232)
187 030.35605 2,287
188 030.36359 324
189 030.36361 {297)
190 030.363<;5 (21'
191 030.36551 30,205
192 0'30.36903 5,670
193 030,36956 17.757)
1•4 030.37034 7,757
195 030,37122 (41
196 030.37142 (61,400)
197 030,37224 [7.219)
198 030.37261 15,942
199 030.37328 111)
200 o:m.37399 (64)
201 o:m.37456 1,727
202 030.37616 48.762
203 030.37636 37,049
204 030.37720 (16)
205 030.37734 (36l
206 030.37736 11821
207 030.37795 187
208 030.37904 39,026
209 030.37913 24,885
210 030.30065 1,563
211 030.36067 15,611
212 030.38078 (9,4511
213 030.38096 (1,6"41
214 030,38116 73.545
215 030.38170 (5)
216 030,36321 140.827
217 030.38391 82,579
218 030,36401 258
219 OJ0.'38422 253
ALLOCATED COST
1111
2SO
43,602
11,184
15,672
1.653
10,033
94,480
ATMOS ENERGY CORPORATION, WESTTEXAS DJVISION
INTERIM COST RECOVERY AND RATE ADJUS1MENT REPORT PROJECT REPORT CY 2016
OESC:RIPTlON OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 (2) BENEFITED
AMARILLO OPERATIONS BLANKET TO COVER REPLl\CEJRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DlAMETER ANOD~S. Ml=.TERS, REGULATORS ANO METER LOOPS ALL-MIX AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS ALL-MIX
AMARILLO OPERATIONS BLANKET FDR NEW SERV1CE LINES, METERS ANO REGULATORS DUE TO CUSTOMER GROWTH ALL-MIX PAMPA OPERATIONS BLANKET TD COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THANG INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS ALL-MIX LUBBOCK OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTH ALL· MIX PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE5 FEET TO 99 FEET OF LESS THAN8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS All-MIX llMl\RILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER. /\NODES. METERS. REGULATORS AND METER LOOPS ALL-MIX PERMIAN BASIN OPERATIONS BLANKET TD COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS Al.L-MIX PERMIAN BASIN OPERATIONS BLANKET TD COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS,
(2) REGULATORS AND METER LOOPS Al.L-MIX BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER
16,520 LOOPS All-MIX BIG SPRING OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER
(1,232) LOOPS /\LL-MIX SEMINOLE/BROWNFIELD OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS,
2,287 REGULATORS AND METER LOOPS ALL-MIX INSTALL CHECK MEASUREMENT DUE TO SYSTEM
324 IMPROVEMENTS ALL-MIX INSTALL CHECK MEASUREMENT DUE TD SYSTEM
(297) IMPROVEMENTS ALL-MIX INST/Ill CHECK MEASUREMENT DUE TD SYSTEM
(21) IMPROVEMENTS All- MIX INST/ILL 421!0FEETOF2 INCHPOLY MAIN/IND INSTALL 1115
30,205 FEET OF 4 INCH POLY MAIN DUE TO CUSTOMER GROWT1-1 ALL-MIX
INSTALL 310 FEET OF 5 FOOT CHAIN LINK FENCE AND 2 20 FOOT 5,670 SLIDE GATES DUE TO BUILDINGILAND IMPROVEMENTS ALL-MIX
INSTALL 660 FEET OF 2 IMCH POLY MAIN AND RETIRE 1.25 INCH (7,757' STEEL SERV1CE8 DUE TO SYSTEM IMPROVEMENTS ALL-MIX
INSTALL 120 FEET OF 2 lNCH POLY MAIN DUE TO CUSTOMER COMMERCIAL 7,757 GROWTH OR INDUSTRIAL
INSTALL 2160FEET Of 2 INOH POLY MAIN AND 20 SERVICES DUE [41 TO CUSTOMER GROWTH RESIDENTIAL
REBUILD LARGE VOLUME METER SETTING DUE TD SYSTEM (61,4061 IMPROVEMENTS ALL-MIX
INSTALL2414 FEET OF2 INCHAND 2784 FEET OF 4 INCH POLY (7.2191 MAIN AND 66 SERVICES DUE TO CUSTOMER GROWTH RESIDENTIAL
INSTALL 1040fEET OF 4 INCH POLY MAIN AND 7 SERVICES DUE COMMERCIAL 15,942 TD CUSTOMER GROWTH OR INDUSTRIAL
COMMERCIAL [111 INSTALL NEW SICK METER DUE TD CUSTOMER GROWTH OR INDUSTRIAL
INSTALL 1366 FEET OF 4 INCH AND 3998 FEET OF 2 INCH POLY (041 MAIN AND 47 SERVICES DUE TO CUSTOMER GROWTH RESIDENTIAL
INSTALL23 FEET OF 2 INCHSTEEl MAIN AND RETIRE 1000 FEET 1,727 OF 2 INCH STEEL MAIN DUE TD SYSTEM INTEGRITY A!.L-MIX
INSTALL 1315 f EET OF 2 INCH POLY MAIN AND 36 SERVICES DUE 48.762 TO CUSTOMER GROWTH RESIDENTIAL
INSTALL 8430 FEET OF 2 INCH PDLV MAIN AND 77 SERVICES DUE 37,049 TO CUSTOMER GROWTH RESIDENTIAL
INSTALL 2280 FEET OF 2 INCH AND 925 FEET OF 4 INCH POLY COMMERCIAL (16) MAIN DUE TD CUSTOMER GROWTH OR INDUSTRIAL
INSTALL 1276 FEET OF 4 INCH POLY MAIN AND 35 SERVICES DUE (36) TO CUSTOMER GRDWT!1 RESIDENTIAL
INSTALL 724 FEET OF 2 INCH POLY MAIN AN!l 11 SERVICES DUE [162) TD CUSTOMER GROWTH RESIDENTIAL
INSTALL :9200 FEET OF 2 JNCH POL y AND 166 SERVICES oui:; TO 187 CUSTOMER GROWTH RESIDENTIAi.
COMMERCIAL 39,026 INSTALL CLASS IX METER DUE TO CUSTOMER GROWTH OR INDUSTRIAL
INSTALL 1120 FEET OF 2 INCH POL V MAIN ANO 6 SERVICES DUE COMMERCIAL 24,685 TO CUSTOMER GROWTH DR INDUSTRIAL
COMMERCIAL 1,563 INSTAl.L METER AND REGULATOR DUE TO CUSTOMER GROWTH OR INDUSTRIAL
INSTALL 500 FEET OF 2 INCH POLY MAlN AND 1 SERVICE DUE TO COMMERCIAL 15,611 CUSTOMER GROWTH OR INDUSTRIAL
INST ALL METER S!OTTING Wini REGULATION DUE TO CUSTOMER COMMERCIAL (9,451 GROWTH OR INDUSTRIAL
INSTAl.L 445 FEET OF 4 INCH POLY MAIN AND 1 SERVICE DUE TO COMMERCIAL 11,684\ CUSTOMER GROWTH OR INDUSTRIAi.
INSTALL 6705 FEET OF 2 INCH POLY MAIN AND 161 SERVICES 73,545 DUE TO CUSTOMER GROWTH RESIDENTIAL
INST All 150 FEET OF 2 INCH POLY MAIN WITH 2 SERVICES DUI= COMMERCIAL 15 TO CUSTOMER GROWTH OR INDUSTRIAL
INSTALL 2500 FEET OF 4 INCH POLY MAIN AND 55 SERVICES OUE 140,82.7 TO CUSTOMER GROWTH RESIDENTIAL
INST ALL 4385 FEET OF 2 INCH POLY MAIN AND 40 SERVICE(S) 82,579 DUE TD CUSTOMER GROWTH RESIDENTIAL
INSTALL 550 FEET OF 4 INOH POLY MAIN AND 4 SERVICES DUE 258 TO CUSTOMER GROWTH RESlDENTIAL
INST All 415 FEET OF 2 INCH POLY MAIN AN!l 10 SERVICES DUE 253 TO CUSTOMER GROWTH RESIDENTIAL
WlX Additions: Page 6of9B
u.ATE PLACED IN GAS PLANTIN
LOCATION PURPOSE Of PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS PMS ION SYSTEM INTEGRITY OECEMBER • 2016
030 TEXAS DMSION SYSTEM INTEGRITY DECEMBER -201S
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2018
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 201£
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS AUGUsr. 2.016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030TEXAS DIVISION SYsTEM IMPROVEMENTS AUGUST~2Q16
030TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWT1-1 AUGUST - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWT1-1 AUGUST- 2016
030 TEXAS DIVISION GROWT1-1 AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVISION GROWTH OCTOBER - 2016
030 TEXAS DIVISION GROWTH AUGUST -2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DMSION GROWTH AUGUST - 2016
030TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2015
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2.016
030 TEXAS DIVISION GROWTH AUGUST - 2.018
030 TEXAS DIVlSIDN GROWTH SEPTEMBER - 2018
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST· 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
LINE ALLOCATEO NO, PROJECT NUMBER COST(1J COST
220 030.38504 29,573 29,573
221 030.38:507 24,901 24,001
= 030.38512 13,040 13,040
223 030.38536 1,025 1,025
224 030,35541 11 11
220 030.38547 (4) 14\
226 030.38553 13,233 13,233
227 030.36558 171) (71\
228 030,35785 1,458 1.458 229 030.38804 17,564 17,56"4
230 030,35515 50.683 50,083
231 030.38816 47.087 47,087
232 030.38523 1.645 1.645
233 030.3S528 1,083 1,083
234 030.36632 (608) (608)
235 030.38833 11,363) (1,363)
236 030.38847 14,484 14,464
2a7 030.38848 39.521 39,521
238 030.38849 1,012,357 1,012,357
239 030.38874 27, 143 27.143
240 030.38919 221,317 221,317
241 030.38935 448 448 242 030.38947 (758] (7551
243 030.38950 (1,472} t1.4nJ
244 03Q.36952 16111 (611l
245 030.38956 5,425 5,425
246 030.38957 1,534 1,S34
247 030.38958 7,617 7,617
248 030.38976 1.419 1.419
249 030.35981 467 467
250 030.38996 2.365 2.365
251 030.39003 434 434
252 030.39004 (333) {333)
253 030,39008 9,963 9,963
254 030.39012 1,873 1,873
255 030,39013 12,334 12,334
256 OJ0.39015 14,365 14,365
257 030,39016 2,878 2.876
258 030.39017 23,544 23,544
259 030.39019 (1001 (1001
260 030.39023 (3,000 (3,000)
261 030.39025 1.145 1.145
262 030.39029 61,666 61,666
263 030.3:9035 59,530 59,530
264 030.39038 47 47
265 030,39046 5,a23 5,823
266 030.39056 553 583
267 030,39057 25,884 25,884
265 030.39058 (1,056) 11,0561
269 030.39067 7.113 7,113
270 030.39008 93,373 93,373
271 030.39070 18.287 18.287
,,,, 030.39071 68,055 e:e,o55
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CT 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
PAMPA OPERATIONS BLANKET FOR N!OW SERVICE LINES, METERS AND REGUl-ATORS DUE TO CUSTOMER GROWTH
HEREFORD OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS ANO REGULATORS DUE TO CUSTOMER GROWTl-l BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF 1-ESS THAN B INCH DIAMETER, ANODES. METERS, REGULATORS AND METER LOOPS INSTALl-4300 FEET OF 4 INCH POlY MAIN DUE SYSTEM IMPROVEMENTS PURCHASE BUILDING FOR THE DALHART OFFICE FOR USE BY WEST TEXAS DIVISION EMPLOYEES
INST All CLASS IX METER SETTING DUE TO CUSTOMER GROVVTI-1 PURCHASE NEW FURNITURE FOR USE BY WEST TEXAS DIVlSION EMPLOYEES INST ALL 2000 FEET OF 2 INCH AND 2430 FEET OF 4 INCH POLY MAIN AND 36 SERVICES DUE TO CUSTOMER GROWTH INSTALL 850 FEET OF 2 INCH POl-Y MAIN DUE TO CUSTOMER GROWTH INSTALL FENCE DUE TO BUILDING IMPROVEMENTS PURCHASE MISCEl-LANEOUS EQUIPMENT FOR USE BY WEST TEXAS DIVlSION EMPl-OYEES PURCHASE 4 6X4 VALVES FDR USE BY WEST TEXAS DMSION EMPLOYEES PURCHASE OAS RANGER/CG! FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 1 SQUEEZE OFF TOOL FOR USE BY WEST TEXAS DIVISION EMPLOYEES INSTALL 3030 FEET OF 2 INCH PDl-Y MAIN AND 34 SERVICES DUE TO CUSTOMER GROWTH INSTALi- 3502 FEET OF 2 INCK AND 1012 FEET OF 4 INCH POLY MAIN AND 70 SERVICES DUE To CUSTOMER GROWTH
PURCHASE 2 SQUEEZE TOOL REMOTE STEEl.JRlSER WITH PUMP & GUIDE STOPS FOR USE BY WEST TEXAS DiVISfON EMPLOYEES PURCHASE MODEMS FOR USE BY WEST TEXAS DIVISION EMPLOYEES INSTALL TOWERS DUE TO SYSTEM IMPROVEMENTS INSTAl-L 560 FEET OF 2 INCH POLY MAIN AND 1 SERVICE DUE TO CUSTOMER GROWTH INST ALL 3150 FEET OF 2 INCH POLY MAIN AND 108 SERVICE(SJ DUE TO CUSTOMER GROWTH PURCHASE DITCH WITCH LINE LOCATOR FOR USE BY WEST TEXAS DIVISION EMPl-OYEES INSTALL SECURITY SYSTEM FOR BUILDING IMPROVEMENTS
INSTAl-1-5M ROOTS METER DUE TO CUSTOMER GROWTH
INSTALL 1 ROOTS METER SEnlNG DUE TO CUSTOM!OR GROWTH INSTALL 300 FEET OF 2 INCH POLY MAIN ANO 1 SERVICE{S) DUE TO CUSTOMER GROWTH INSTALi-MEW FENCE AND CONCRETE FOR BUILDING IMPROVEMENTS PURCHASE 1 REMOTE STEELJRISER WITH PUMP AND GUIDE STOPS FOR USE BV WEST TEXAS DIVISION EMPLOYEES
INSTALi- 3M ROOTS METER DUE TO CUSTOMER GROWTH
INSTALL CLASS IX METER SETTINO DUE TO CUSTOMER GROWTH PURCHASE 3 SQUEEZE TOOl-S FDR USE BY WEST TEXAS DIVISION EMPl-OYEES
INST ALL CLASS IX METER SETTINO DUE TO CUSTOMER GROWTH INSTALi- 520 FEET OF 2 INCH Pol-Y MAIN AND 1 SERVICE DUE To CUSTOMER GROWTH PURCHASE 2 SHORTCUT VALVE ASSEMBl-IES,2 PLUGGING MACHINES. 2 PLUG HEAD. 1 SHORT Pl-UG HEAD HOLDER FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 1 COi TRAK IT II! FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 6 SEN ITS GDl-D FDR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 1 3M DYANTEL 2500 AND 1 3M DYANTEL 2573 FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 1 GATOR TRAii-ER FOR USE BY WEST TEXAS DIVISION EMPl-OYEES PURCHASE JOHN DEERE GATOR FOR USE BY WEST TEXAS DIVISION EMPLOYEES INSTALL 300 FEET OF2 INCH POl-Y MAIN AND 1 SERVlCE(S)DlJE TO CUSTOMER GROWTH PURCHASED CURRENT INTERRUPTERS FOR USE BY WEST TEXAS DIVISION EMPLOYEES INSTl\l.L CLASS 9 METER SETTING To INCi-UDE METER AND REGULATION DUE TO CUSTOMER GROWTH
FINISH COMMON EMPLOYEE AREA AND KITCHEN AND PURCHASE FFE DUE TD BUILDING AND I-AND IMPROVEMENTS PURCHASE FFE FOR 1-U!l!IOOK BUI LOI NG DUE TO BUii-DiNG AND I-AND IMPROVEMENTS ~NSTALl 3M ROOTS METER SETTING DUE TO CUSTOMER GROWTH ORDER ELECTRO FllSION PROCESSOR FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE NEW HEATING AND AC UNIT FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE ALI- TERRAIN XUV VEHICl-E FOR USE BY WEST TEXAS DIVISION EMPl-OYEES INST ALL 210 FEET OF . 75 INCH POLY MAIN AND 1 SERVICE( SI DUE TO CUSTOMER GROWTH INSTAl-L 9675 FEET OF 2 INCH POl-Y MAIN AND 16 SERVICES DUE TO CUSTOMER GROWTH INSTALL3665 FEET OF2 INCH POLY MAIN AND INSTALL970 FEET OF 4 INCH POLY MAIN AND45SERVICE(S)OUETOCUSTOMER GROWTH PURCHASE OF TOW PLUGGING EQUIPMENT FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 5 TOW TAPPING MACHINES WITH 5 SETS OF 21N AND 31N HOLE SAW ASSEMBLIES FOR USE SY WEST TEXAS DIVISION EMPLOYEES
WTXAdditions Page/ of 98
CUSTOMERS BENEFITED
RESIDENTIAi-
RESIDENTIAL
ALL- MlX
ALl--MIX
ALl--MIX COMMERCIAL
OR INDUSTRIAL
ALl--MIX
RESIDENTiAL
ALl-·MIX ALL-MIX
All-MIX
ALL-MIX
ALl--MIX
ALL-MIX
RESIDENTIAL
RESIDENTIAL
ALL-MIX
ALl--MIX All-MIX
COMMERCIAL OR INDUSTRIAL
RESIDENTIAL
Al-L-MIX Al-L-MIX
COMMERCIAL OR INDUSTRIAL
COMMERCIAL OR INDUSTRIAi-
COMMERCIAL OR INDUSTRIAL
Al-1--MIX
ALL- MIX COMMERCIAL
OR INDUSTRIAL COMMERCIAL
OR INDUSTRIAL
ALl--MIX COMMERCIAL
OR INDUSTRIAL COMMEROIAI-
OR INDUSTRIAi-
All-- MIX
All-MIX
ALl--MIX
ALL-MIX
ALL-MIX
ALL- MIX COMMERCIAL
DR INDUSTRIAL
All-MIX COMMERCIAL
DR INDUSTRIAL
ALL-MIX
ALL-MIX COMMERCIAL
OR INDUSTRIAL
Al-1--MIX
ALL- MIX
Al-1--MIX COMMERCIAL
OR fNDUSTRIAL
ALl--MIX
RESIDENTIAL
ALL· MIX
ALl--MIX
DATE PLACED IN GASPLANTIN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DMSION GROWTH DECEMBER· 2016
030 TEXAS DIVISION GROWTH DECEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 2016
000 TEXAS D!VlSION STRUCTURES AUGUST· 2016
030 TEXAS DIVlSION GROWTH AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030TEXAS DIVISION GROWTH AUGUST - 2016
030TEXAS DIVISION GROWTH AUGUST~ 2016
030TEXAS DIVISION STRUCTURES JANUARY -2016
030 TEXAS DIVISION EQUIPME~'T AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST-2016
030 TEXAS DIVISION EQUIPMENT AUGUST-2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST -2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER- 2016 030 TEXAS OIVlSIDN SYSTEM IMPROVEMENTS DECEMBER- 2018
030 TEXAS DIVlSION GROWTH AUGUS1 • 2.016
030 TEXAS DIVlSION GROWT!l AUGUST • 2016
030TEXAS DIVISION EQUIPMENT AUGUST-2:()16
030 TEXAS DIVISION STRUCTURES AUGUST • 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUOUST-2016
030 TEXAS DIVISION GROWTH AUGUST-2016
030 TEXAS DIVISION STRUCTURES AUGUST -2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
0'30 TEXAS DIVISION GROWTH OOTOBER-2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVlSION EQUIPMENT AUGUST - 2016
030 TEXAS DIVlSION GROWTH AUGUSi - 20115
030TEXAS DIVISION GROWTH AUGUST· 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST· 2016
030 TEXAS DIVISION EQUIPMENT AUGUST-2016
030 TEXAS DIVISION EQUIPMENT AUGUST· 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST· 2018
030 TEXAS DiVISlON EQUIPMENT JANUARY - 2016
030 Tl=XAS DIVISION GROWTH AUGUST· 2016
030 TEXAS DIVISION STRUCTURES OC'fDBi:;R • 2016
030TEXAS DIVISION STRUCTURES OCTOBER - 2016
030 TEXAS DIVISION GROWTH AUGUST • 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST -2016
030 TEXAS DIVISCDN GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH SEPTEMBER • 2016
030 TEXAS DMSION GROWTH AUGUST - 2016
030 TEXAS DMSION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST· 2016
LINE ALLOCATED NO. PROJECT NUMBER COST[1) COST
273 030.39073 17,529 17,529
274 030.39074 4,348 4,348
275 030.39078 :5,804 5,804
276 030.39079 3,914 3,914
277 030.39081 14,734 14,734
276 030.39064 38,050 38,050
279 030.39065 7,811 7,:011
260 030.39066 10.408 10,408
281 030.39067 6,309 6,309
262 030.30068 443 443
283 030.39089 2,992 2,992
284 OJtJ.39090 1,687 1,687
285 030,39091 2,773 2,773
286 030.39092 22,670 22,670
287 030.39094 3.811 3,611
288 030.39110 1,998 1,998
289 030.39111 13,537 13,537
290 030.39114 14,:220 14,220
291 030.39119 14,237 14,237
292 030.39131 209,381 209,381
293 030.39134 290,103 290,103
294 030.39144 79,056 79,056
295 030.39154 17,121 17,121
296 030.::19157 100,528 100,528
297 030.39156 15,741 15,741
'"" 030.39181 ;2,355 2,355
299 030.39196 7,140 7.140
300 030.38220 (1.667) (1,667)
301 030.39221 (10,318) f10,3181
302 030,39226 3,744 3,744
303 030.39234 15,064 15,064
304 030.39235 41,621 41.621
305 030.39237 100,009 109,000
300 030.39244 5,161 5,161
307 030.39245 36,334 36,334
306 030.39247 00,361 66,361
309 030.39248 7,687 7,687
310 OOC.39253 26,119 26,119
311 030.39264 25,40• 25,408
312 030.39265 6,950 6,950
313 030,3926:9 5.174 5,174
314 030.39272 60,567 60,567
316 030.39275 9,622 9.622
316 030.39277 13,2031 (3,2031
317 030.39283 132,840 132,840
318 030.39291 72,1508 72,608
319 030.39298 .!l,133 4,133
320 030.39:a01 {3,0901 (3,090
321 030.39326 4,416 4,416
322 030.39367 83,712 63,712
ArMos Er4E"RGYCORPORAUD.N, WESTTEXAS DIVIS.ION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT Ci 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 {2]
PURCHASE OF 8 SENSIT GOLD LEAK DETECTION UNITS FOR USE; BY WEST TEXAS DIVISION EMPLOYE;ES PURCHASE 2 ESCAPE PACKS FOR USE BY WEST TEXAS DMSION EMPLOYEES PURCHASE OF MISSILE BORE TOOL FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 3 CURRENT INTERRUPTERS FOR USE BY WEST T8<AS DIVISION EMPLOYEES PURCHASE OF POLY FUSION EQUIPMENT· 5 EA. OF 21N TO 61N POLY SCRAPERS AND 41N IPS ROTARY SCRAPER FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 3 INCH TAPPING AND PLUGGING EQUIPMENT FOR THE BIG SPRING AREA FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE OF ETHANE DETECTOR FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE OF ONE BIG TEX DUMP TRAILER WITH RAMPS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 1 3M DTNATEL 2500 FOR USE BY WEST TEXAS DIVISION EMPLOYEES PUROHASE 3 SENSIT UNITS FOR USE BY WEST T8<AS DIVISION EMPLOYEES PURCHASE 2 MUSTANG SQUEEZE TOOLS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 1 5X12 lITIUTY TRAILER FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 1 6X12 WITH RAMP FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE 1 JOHN DEERE GATOR FOR USE BY WEST T8<AS OIVISION EMPLOYEES
PURCHASE 9 314"-ti MINI CLAMPS@$145.00 EAAND 5 2"-6 PIPE SCRAPERS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE TRAILER FDR NEW ATV FOR USE BY WEST Tl=XAS DIVISION EMPLOYEES
PURCHASE 2 INCH AND :a INCH TAP'P!NG AND PLUGGING EQUIPMENT FOR USE BY WEST TEXAS OMS ION EMPLOYEES PURCHASE 13M DYANTEL 2500AND1 3M DYANTEL 2573 FOR USE BY WEST TEXAS DIVISION EMPLOYEES
PURCHASE OF 3 UNIVERSAL PROCESSORS; ELECTROFUSION EQUIPMENT FOR USE BY WEST TEXAS DMSION EMPLOYEES INSTALL4858 FEET OF21NCH POLY MAIN, INSTALL 3723 FEET OF 4 INCH POLY MAIN, AND 61 SERVICE(Sl DUE TO CUSTOMER GROWTH INSTALL2.750 FEET 4 INCH AND 10,680 FEET2 INCH POLY TO SERVE 143 LOTS DUE TO CUSTOMER GROWTH INSTALL4005 FEET OF 2lNCH POLY MAIN, INSTALL 1815 FEET OF 4 INCH POLY MAIN, AND 30 SERVICE(s) DUE TO CUSTOMER GROWTH PURCHASE OF 4 NO·BlOW STOP CHANGERS FOR USE BY WEST TEXAS DIVISION EMPLOYEES INSTALL 6145 FEET OF 2 INCH POLY MAIN DUE TO CUSTOMER GROWTH INSTALL 1096 FEET OF 2 INCH POLY MAIN DUE TO CUSTOMER GROWTH
INSTALL ROOTS METER PUE TO CUSTOMER GROWTH PURCHASE 1 MUELLER BYPASS TOOL FOR USE BY WEST TEXAS DIVISION EMPLOYEES
INSTALL ROOTS METER DUE TO CUSTOMER GROWTH INSTALL662FEETOF 2 INCH POLY MAIN AND 1 SERVICE{SJ DUE TO CUSTOMER GROWTH INSTALL233 FEETOF2 INCH POLY MAIN AND 1 SERVICE{S] DUE TO CUSTOMER GROWTH INST ALL 6145 FEET OF 2 INCH POLY MAIN AND 1 SERVICE1S) DUE TO CUSTOMER GROWTH INST All 2270 FEET OF 2 INCH POLY MAIN AND 1 SERVICEjS) DUE TO CUSTOMER GROWTH INSTALL 6045 FEET OF 2 INCH POLY MAIN AND 60 S!;RVICE(S) DUE TO CUSTOMER GROWTH PURCHASE 1 BREATHER BOX, 2 RESPIRATOR CARTRIDGE REPLACEMENTS, AND 4 100FT AIR HOSES FOR USE BY WEST TEXAS DIVISION EMPLOYEES
PURCHASE 1 63iN CMD CROSSBEAM FROM HEATH CONSULTANTS FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE; 1 VAPOR EXTRACTOR UNIT FROM EGW FOR USE BY WEST TEXAS DIVISION EMPlOYEES PURCHASE 1 MUELLER BYPASS TOOL KIT FOR USE BY WEST TEXAS DIVISION EMPLOYEES
INSTALL REGULATOR STATION DUE TO SYSTEM IMROVEMENTS PURCHACED 6 NO BLOW VALVE CHANGERS .75 TO 1.25 INCH FOR USE BY WEST TEXAS DIVISION EMPLOYEES
PURCHASE BRICK LIGHT LED FULL EXPLOSION PROOF, FLOOD LIGHT, FOR USE BY WEST T8<AS DIVISION EMPLOYEES PURCHASE 2 INCH BY 1 INCH ADAPTER FOR USE BY WEST TEXAS DIVISION EMPLOYEES PURCHASE LINE TAMER EQUIPMENT TO FACILITATE INSTALLATION Of ROLLED POLY PIPE FOR USE BY WEST TEXAS DIVISION EMPLOYEES
INST ALL SM ROOTS METERS DUE TD CUSTOMER GROWTH INST ALL 360 FEET OF 2 INCH POLY MAIN AND 1 MASTER METER SETTING DUE TO CUSTOMER GROWTH INSTALL PATIO AT LUBBOCK DIVISION OFFICE DUE TO BUI LOI NG IMPROVEMENTS PURCHASE C120-9 CNG COMPRESSOR AND ACCESSORIES FOR USE BY WEST TEXAS DIVISION EMPLOYEES INST ALL 112 FEET OF 2 INCH POLY MAIN AND 1 SERVICEjS) DUE TO CUSTOMER GROWTH INSTALL 940 FEET OF 2 INCH POLY MAIN AND 1 SERVICEjS) DUE TO CUSTOMER GROWTH INSTALL 17fEETOF2 INCHPOLY MAIN AND 1 SERVICE(S)DUE TO CUSTOMER GROWTH REBUILD MEASUREMENT STATION AND TRANSWESTERN TAKEOFF DUE TO SYSTEM IMPROVEMENT
WTX Additions P<1gfi! $ of98
CUSTOMERS BENEFITED
AUL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
ALL-MIX
RESIDENTIAL COMMERCIAL
OR iNDUSTRIAL COMMERCIAL
DR INDUSTRIAL
Al.l-MIX COMMERCIAL
OR INDUSTRIAL COMMERCIAL
OR INDUSTRIAL
RESIDENTIAL COMMERCIAL
OR INDUSTRIAL COMMERCfAL
OR INDUSTRIAL
RESIDENTIAL
ALL-MlX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL.MIX
ALL-MIX
All-MIX COMMERCIAL
OR INDUSTRIAL COMMERCIAL
OR INOUSTRIAL
ALL-MIX
ALL- MIX
RESIDENTIAL COMMERCIAL
OR INDUSTRIAL
ALL· MIX
ALL· MIX
PATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVLCE
030 TEXAS DMSION EQUIPMENT AUGUST· 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DMSION EQUIPMENT AUGUST y 2016
030 T8<AS DIVISION EQUIPMENT AUGUST - 2016
030 T8<AS DIVISION EQUIPMENT AUGUST· 2018
030 TEXAS DIVISION EQUIPMENT AUGUST -2016
030 TEXAS DIVISION EQUIPMENT AUGUST- 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST· 2016
030 TEXAS DIVISION EQUIPMENT FEBRUARY- 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST -2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2.016
030 TEXAS OIVISION EQUIPMENT AUGUST· 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 T8<AS DIVISION EQUIPMENT AUGUST • 2016
030 TEXAS OIVISION EQUIPMENT AUGUST· 2016
030 TEXAS DIVISION GROWTH SEPTEMBER - 2016
030 TEXAS DIVISION GROWTI4 DECEMBER· 2016
0'30 TEXAS OIVIS!ON GROWTH AUGUST • 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION GROWTH StPTE:MBER • 201B
030 TEXAS DIVISION GROWTH OCTOBl=R - 2016
030 TEXAS DIVISION GROWTH AUGUST· 2016
030 TEXAS DIVISION EQUIPMENT AUGUST· 2016
030 TEXAS DIVISION GROWTH AUGUST~ 2016
030TEXAS DIVISION GROWTH APRIL-2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 T8<AS OIVISION GROWTH AUGUST-2016
030 TEXAS DIVISION GROWTH AUGUST-2016
030 TEXAS DIVISION GROWTH OCTOBER · 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST· 2016
030 TEXAS DIVISION EQUIPMENT AUGUST -2016
030 TEXAS DIV!SION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER • 2016
030 TEXAS DIVISION EQUIPMENT AUGUST-2'l16
030TEXAS DIVISION EQUIPMENT AUGUST -2'l16
030 TEXAS DIVISION EQUIPMENT AUGUST · 2016
030 TEXAS DMSlON EQUIPMENT AUGUST· 2016
030 TEXAS DIVISION GROWTH AUGUST -2016
030 TEXAS DIVISION GROwn-1 AUGUST -2016
030 TEXAS DIVISION STRUCTURES SEPTEMBER - 2016
030 TEXAS DMSION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH SEPTEMBER • 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER • 2016
LINE ALLOCATED NO, PROJECT NUMaER COST(1} COST
323 030.39373 9.320 9,3;20
324 030.39369 166,475 166,475
325 030_39396 564,666 5a4,866
326 030.39403 373,579 373,579
327 030.39408 10,600 10,600
326 030.39420 141,®9 141,509
329 030.39450 95,43B 95,436
330 030.39472 35,932 35,932
331 030.39476 2,001 2.001
332 030.39477 1,738 1,738
333 {)30_39484 38,857 38,857
334 030.39493 3,728 3,728
335 030.39496 4,052 4,052
336 030.39496 19,026 19,026
337 030.39512 976 976 338 030.39536 17,466 17,486
339 030.39564 4,493 4,493
340 030.39566 101,023 101,023
341 030.39623 7,393 7,393
342 030.39631 2,226 2,226
343 030.39633 4,947 4,947
344 030.39645 703 703
345 030.39647 8,720 B,720
346 030.396515 10,119 10,119
347 030.39659 24,007 24,667
348 030:39662 61,801 61,801
349 030.39003 1,012 1,012
350 030.3:9670 646 646
351 030.39688 119,328 119,328
352 030,39697 19.609 19.809
353 030.39698 63,976 53,976
354 030.39716 3.452 3,452
355 000.39727 3,116 3,116
356 000.39774 70,512 70,512
357 0'30.39778 8,491 6,491
356 030.39782 20,307 20,307
359 030.39784 1747) 17471
360 030.39790 470 470
361 030.39791 92,629 9;2,6;29
362 030.39807 25,635 25,636
363 030.39;809 427 427
364 030.39820 9,970 9,970
365 030.39827 {6,380) {6,380]
386 030.39851 12,413 12.413
367 030.39893 7,442 7.442
386 030.39920 60,420 80,420
369 o:m.39963 1,696 1,696
370 o:m.39984 7,657 7,567
371 030.39991 7,209 7,2.09
372 030.40031 9,927 9,927
373 030.40035 25,081 25,081
374 030.40056 5,991 5,991
ATMOS ENERGY CORPORATION, WESTTEXAS DIVISION INTERIM COST RECOVERY ANO RATE ADJUSTMENT REPORT
PROJECT REPORT CY 1016
DESCRIPTION OF COMPLETED PROJECTS OEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 175 FEET EXTENSION AND 3 SERVICE(S) DUE TO CUSTOMER GROWTH
INSTALL460 FEET OF 4 INCH STEEL MAIN, IMSTALL6SFEET OF 4 INC!l POLY MAIN AND 1 SERVICE($) DUE TO CUSTOMER GROWTH PURCHASE ANDlNSTAll836100GM, 94 200GM, 4,019 300GM, 30 400GM, 140 60CGM, AND 12 700/9000M METER READERS PURCHASE AND INSTALL400 100GM, 2,500300GM, AND 100 600GM, METER READERS AND 50 ARMS/ROOTS METERS DUE TO SYSTEM IMPROVEMENTS PURCHASE 6 5X15 FT STEEL PLATES FDR CONSTRUCT JON FOR USE BY WEST TEXAS DIVISION EMPLOYEES INSTALL 1245 FEET OF 4 INCH POLY MAIN AND INSTALL5445 FEET OF 2 INCH POLY MAIN OUE TD CUSTOMER GROWTH INSTALL3150 FEET Of 21NCH AND 1115 FEET Of 4 INCH POLY AND 60 SERVICES DUE TO CUSTOMER GROWTH INSTALL 1880 FEET OF 2 INCH POLY MAIN AND 12 SERVICES DUE TO CUSTOMER GROWTH INSTALL 160 FEET OF 2 INCH POLY MAIN AND 2 SERVICEjS) DUE TO CUSTOMER GROWTH
PURCHASE TRACK IT Ill WITH CARRY POUCH PROBE, PIGTAii... AND FILTER FOR USE !!YWESTTEXAS DIVISION EMPLOYEES INSTALL2475 FEET OF 4 INCH POLY MAIN, INSTALL 500 FEET Of 2 INCH POLY MAIN, AND 2 SERVICE(S) DUE TO CUSTOMER GROWTH PURCHASE TDW PLUGGING ACCESSORIES FOR USE BY WEST TEXAS DIVISION EMPLOYEES
INST ALL NEW PRIVACY FENCE FOR REGULATOR STATION IN RESIDENTIAL SUBDIVISION DUE TO BUILDING IMPROVEMENTS PURCHASE CP WATCHDOG REMOTE MONITORING UNITS FOR USE BY WEST TEXAS DIVISION EMPLOYEES
INST ALL 900 FT Of 2 INCH POLY DUE TO CUSTOMER GROWTH REBUILD METER SETTING DUE TO SYSTEM IMPROVEMENT INSTA!-L ROOTS METER ANO CROSS STREET2 INCH PE SERVICE DUE TD CUSTOM!OR GROWTH INSTALL 4175 FEET OF 2 INCH POLY MAIN AND 40 SERVJCE(S) DUE TD CUSTOMER GROWTH
PURCHASE OF 10 OFFICE CHAIRS AND MISC OFFICE EQUIPMENT FOR USE BY WEST TEXAS DIVISION EMPLOYEES INSTALL CLASS IX 7M ROTARY METER AND SETIING DUE TO CUSTOMER GROWTH INST ALL 72 FEET OF 2 JNCH POLY MAIN AND 1 SERVICE( SJ DUE TO CUSTOMER GROWTH INSTALl.155 FEET OF 2 INCH POLY MAIN AND 1 SERVICE(S) DUE TO CUSTOMER GROWTH INSTALL ROOTS METER, REGULATION AND RELIEF VALVE DUE TO CUSTOMER GROWTH PURCHASE 5 NEW SENS ITS FOR USE BY WEST TEXAS DMSIDN EMPLOYEES INSTALL 1450 FEETOF2 INCH POLYAND200fEET OF 4 INCH POLY AND 11 SERVICES DUE TO CUSTOMER GROWTH INSTALL 2692 FEET OF 4 INCH POLY MAIN AND RETIRE 2692 FEET OF 2 INCH POLY MAIN DUE TO SYSTEM IMPROVEMENT INSTALL 3 SERVICE(S) DUE TO CUSTOMER GROWTH INSTALL 973 FEET OF 2 INCH POLY AND 3 SERVICES DUE TO CUSTOMER GROWTH INSTALL 3230 FEET OF 2 INCHPDLY MAIN AND 947 FEET Of 4 INCH POLY DUE TO CUSTOMER GROWTH
INSTALL 7M ROOTSMETER DUE TO CUSTOMER GROWTH INST ALL 2790 FEET OF 4 INCH POLY DUE TO SYSTEM IMPROVEMENTS INSTALL 290 FEET OF 2 INCH POLY MAIN AND 1 SERVICE(S) DUE TD CUSTOMER GROWTH PURCHASE PLUGGING EQUIPMENT FOR USE BY WEST TEXAS DIVISION EMPLOYEES INSTALL 2330FEETOF2 INCH POLY MAIN ANO 78 SERVICElS) DUE TO CUSTOMER GROWT11 INST ALL CLASS IX 31N 7M ROTARY METER SETTING DUE TO CUSTOMER GROWTH INSTALL 1465 FEET OF 6 INCH POLY MAIN DUE TO CUSTOMER GROWTH RELOCATE 064 FEET OF 3 INCH STEEL MAIN DUE TO PUBLIC IMPROVEMENT INSTALL 500 FEET OF 2 INCH POLY MAIN AND 1 SERVICE(S) PUE TO CUSTOMER GROWTH INSTALL TOWERS FOR WMR EQUIPMENT IN BROWNFIELD AND SEMINOLE DUE TO SYSTEM IMPROVEMENT INST ALL 900 FEET OF 2 INCH POLY MAIN DUE TO CUSTOMER GROWTH INSTALL 74 FEET OF 2 INCH POLY MAIN AND 1 SERVICE{S) OUE TO CUSTOMER GROWTH
INSTALL 1 SERVICE(SfDUE TO CUSTOMER GROWTH INST ALL 1550 FEET OF 2 INCH POLY MAIN AND 1 SERVICE(S) DUE TO CUSTOMER GROWTH INSTALL 11M ROOTS METER SETTING DUE TO CUSTOMER GROWTH INSTALL 950 FEET OF 4 INCH POLY MAIN DUE TO CUSTOMER GROWTH INSTALL 2335 FEET OF 2 INCH POLY MAIN AND 30 SERVICES DUE TO CUSTOMER GROWTH PURCHASE 1 CHART RECORDER C>-15 PSI 24 HR ROTATION PORTABLE PARMER MODEL 185 FOR USE BY WEST TEXAS DIVISION EMPLOYEES INST ALL 3M ROOTS METER SETTING DUE TO CUSTOMER GROWTH INSTALL 500 FEET OF 2 INCH POLY MAIN DUE TO CUSTOMER GROWTH RELOCATE 298 FEET Of 2 INCH STEEi- MAIN AND 1 SERVICE WITH 396 FEET OF 2 INCH POLY MAIN DUE TO PUaLIC IMPROVEMENT INSTALL 1585 FEET OF 4 INCH POLY MAIN, INSTALL 290 FEET OF 2. INCH POLY MAIN, AND 1 SERVICE{S) DUE TO CUSTOMER GROWTH
INSTALL 240 FEET OF 2 INCH MAIN DUE TO CUSTOMER GROWTH
WTXAddU!Qm Page 9 of98
CUSTOMERS BENEFITED
RESIDENTIAL
COMMERCIAL OR INDUSTRIAL
ALL-MIX
ALL-MIX
ALL-MIX
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
ALL-MIX
COMMERCIAL OR INDUSTRIAL
ALL" MIX
ALL-MIX
ALL-MIX COMMERCIAL
OR INDUSTRIAL ALL-MIX
COMMERCIAL OR INDUSTRIAL
RESIDENTIAL
ALL-MIX COMMERCIAL
OR INDUSTRIAL
RESIDENTIAL COMMERCIAL
OR INDUSTRIAL COMMERCIAL
OR INDUSTRIAL
ALL-MIX
RESIDENTIAL
ALL-MIX RESIDENTIAL COMMERCIAL
OR INDUSTRIAL
RESIDENTIAL COMMERCIAL
OR INDUSTRIAL
ALL-MIX COMMERCIAL
OR INDUSTRIAL
ALL-MIX COMMERCIAL
OR INDUSTRIAL COMMERCIAL
OR INDUSTRIAL
RESIDENTIAL
ALL-MIX
ALL-MIX
ALL-MIX
RESIDENTIAL
RESIDENTIAL COMMERCIAL
OH INDUSTRIAL COMMERCIAL
OR INDUSTRIAL COMMERCIAL
OR INDUSTRIAL COMMERCIAL
OR INDUSTRIAL
RESIDENTIAL
ALL-MIX COMMERCIAL
OR INDUSTRIAL COMMERCIAL
DR INDUSTRIAL
ALL· MIX
COMMERCIAL DR INDUSTRIAL
RESIDENTIAL
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH DECEMBER • 2016
030 TEXAs DIVISION SYSTEM lMPROVEMENTS DECEMBER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEKAS OJVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISJON GROWTH AUGUST - 0016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION STRUCTURES AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DMSION GROWTH AUGUST- 2016 030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2010
030TEXAS DIVISION GRDWTH DECEMBER -2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXA.S DIVISION GROWTH DECEMBER" 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST-2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST -2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 2016 030 TEXAS DIVISION GROWTH OCTOBER-2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2018
030 TEXAS DIVISION EQUIPMENT SEPTEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH OCTOBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2Q16
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISlON GROWTH AUGUST - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION GROWTH AUGUST-2016
030 TEXAS DIVISION GROWTH AUGUST -2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH SEPTEMBER - 2016
030 TEXAS DIVISION GROWTH SEPTEMBER - 2016
030 TEXAS DIVISION GROWTH SEPTEMBER • 2018
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION EQUIPMENT AUGUST - 2016
030 TEXAS DIVISION GROWTH SEPTEMBER - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DJVISION GROWTH AUGUST -2016
LINE ALLOCATED No. PROJECT NUMBER COST(1) COST
375 030.40058 306,814 306,814
376 030.40059 93,644 93,644
377 030.40066 [650) [650]
378 030.40088 50.985 50,965
379 030.40089 60,233 60,233
380 030.40092 58.006 58,006
361 030.40116 2,093 2,093
382 030.40125 :lll.204 36,204
363 030.40234 22,001 22.001
384 030.40240 121,240 121.240
385 030.40309 1,659 1,659
385 030.40349 35,193 35,193
387 030.40363 148.468 148,466
388 030.40377 23,230 23,230
389 030.40380 29,079 29,079
390 030.40398 123,840 123,840
391 030.40417 9,635 9,635
392 030.40423 9,016 9,016
393 030.40424 4,270 4,270
394 030.40439 3,686,465 3.686,455
305 030.40457 (5,152 (5,152)
396 030,40505 6,059 5.059
397 030.40507 54,981 54,981
398 030.40510 5,007 5,007
399 030.40523 (26,847) (26.847)
400 030.40525 (7,955) (7,955)
401 030.40535 rB45l rB45l
402 030.40554 177,111 177.111
403 030.40568 5,369 5,369
404 030.40595 7,540 7,540
405 030.40600 166 166
406 030.40622 2,921 2,921
407 030.40636 22.872 22,872
408 030.40638 38.975 38,975
409 030.40039 890,108 800,108
410 030.40642 20.539 20,539
411 030.40643 15,159 15,159
412 030.401355 5.132 5,132
413 030.40688 18,91.EI 18,919
414 030.40677 424,951 424,951
415 030.40683 6,863 6,863
416 030.40722 4,926 4,928
417 03M0747 10,440 10,440
418 030.40753 15,017 15,017
419 030.40754 154 154
420 030-40786 56,115 56,115
421 030.40777 109,796 109,798
422 030-40805 58,831 58,8,'31
423 030.40B54 (8,182) 18,182)
424 030.40858 19.445 19.445
425 030.40870 4,115 4,115
ATMOS ENERGY CORPORATION, WES.TT:EXAS DlVISION
INTERIM CO.ST RECOVERY ANO RATE ADJVSTMEtllT REPORT PROJECT REPORT Cf 2016
DESCRIPTION OF COMPLETED PROJECTS lJEDJCATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 {2) BENEFITED
INSTALL 2.000 FEET OF 16 INCH STEEL AND 1 METER AND COMMERCIAL SErnNG DUE TO CUSTOMER GROWTH OR INDUSTRIAL INSTALL 2822 FEET OF 2 INCH POLY MAIN DUE TO CUSTOMER GROWTH RESIDENTIAi. INSTALL 126 FEET OF 2 INCH POLY MAIN WITH 4 INCH CASING PIPE AND 2 SERVICE{S] WITH MASTER METER DUE TD CUSTOMER GROWTH RESIDENTIAL INSTALL 222 FEET OF2 INCH POLY MAIN AND INSTALL 1147 FEET OF 4 INCH POLY MAlN DUE TO CUSTOMER GROWTH RESIDENTIAL INSTALL 2950 FEET OF 2 INCH POLY MAIN AND 21 SERVICE($) DUE TO CUSTOMER GROWTH RESIDENTIAL INSTALL 1210 FEET OF 4 INCH POLY MAIN AND 945 FEET DF2 INCH POLY MAIN DUE TO CUSTOMER GROWTH RESIDENTIAL INSTALL 300 FEET OF 2 INCH POLY MAIN DUE TO CUSTOMER GROWTH ALL-MIX INSTAU. 605 FEET OF2lNCH POLY MAIN AND 1 SERVICE(S) DUE TO CUSTOMER GROWTH ALL-Ml)( INSTALL 770 FEET OF 2 JNCH POLY MAIN DUE TO CUSTOMER COMMERCIAL GROWTH OR INDUSTRIAL
INST ALL O<l70 FEET OF 2 INCH POLY MAIN, 1300 FEET OF 4 INCH POLY MAIN AND 49 SERVICE($) DUE TO CUSTOMER GROWTH RESIDENTIAi. SEMINOLE OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5FEETT099FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS ALL-MIX INSTALL 1000 FEET OF 2 INCM POLY MAIN DUE TO CUSTOMER COMMERCIAL GROWTH OR INDUSTRIAL
INSTALL 640 FEET OF 4 INCH POLY MAIN. 4990 FEET OF 2 INCH POLY MAIN AND 49 SERVICE(S) DUE TO CUSTOMER GROWTH RESIDENTIAL INSTALL 600 FEET OF 2 INCH POLY AND 12 SERVICES DUE TO CUSTOMER GROWTH RESIDENTIAL INSTALL 660 FEET OF 2 INCH POLY MAIN DUE TO CUSTOMER GROWTH RESIDENTIAL INSTALL 3300 FEET OF 2 INCH POLY MAIN TO CUSTOMER GROWTH ALL-MIX
COMMERCIAL INSTALL 3M ROOTS METER DUE TO CUSTOMER GROWTH OR INDUSTRIAL
COMMERCIAL INSTALL 5M ROOTS METER DUE TO CUSTOMER GROWTH OR rNPUSTRIAL PURCHASE BOMAG POWER RAMMER FOR COMPACTION FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX CONSTRUCT l<EW BUILDING FOR !.EVELLAND OPERATIONS DUE TO BUILDING/LAND IMPROVEMENTS #NIA INSTALL 640 FEET OF 2 INCH POLY MAIN DUE TD CUSTOMER COMMERCIAL GROWTH OR INDUSTRIAL INSTALL COMMUNICATION PACKAGE PUE TD SYSTEM IMPROVEMENTS ALL-MIX PURCHASE 8 SQUEEZE TOOLS FOR USE BY WEST TEXAS DIVISION EMPLOYEES Al.L-MIX INSTALL 178 FE:ETOF2 INCHPDLY MAIN AND 1 COMMERCIAL COMMERCIAL SERVICE DUE TO CUSTOMER GROWTH DR INDUSTRIAL INST Al.L 676 FEET OF 2 INCH POLY MAIN AND RETIRE 3494 FEET OF 2 INCH S1EEL MAIN AND 145 SERVICES DUE TO PUBLIC IMPROVEMENT Al.L-MIX INSTALL 3M ROTARY METER SETTING DUE TD CUSTOMER COMMERCIAL GROWTH OR INDUSTRIAL INSTA\J. 1000 FEET Of 2 INCH POLY MAIN ONE CLASS 9 METER COMMERCIAL DUE TO CUSTOMER GROWTH OR INDUSTRIAL INSTALL6150 FEET OF 2 INCH POLY, 1430FEET OF 4 ~NCH POLY, AND 80 SERVICES DUE TO CUSTOMER GROWTH RESIDENTIAL INSTALL 150FEETDF2 INCH POLY AND 1 SERVICE DUE TO CUSTOMER GROWTH ALL-MIX CREDENZA FDR MANAGER'S OFFICE DUE TO BUILDING IMRPOVMENTS ALL-MlX INSTALL CLASS 9 METER SErnNG TO INCLUDE METER AND COMMERCIAL REGULATION DUE TO CUSTOMER GROWTH OR INDUSTRIAL PURCHASE 1 SET OF LIFT FORKS FOR BACKHOE FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX INSTALL 1564 FEET OF 2 INCH POLY MAIN PUE TD CUSTOMER GROWTH RESIDENTIAi. INSTALL 440 FEET OF 4 INCH POLY MAIN AND 1 SERVICE AND RETIRE 220 FEET OF 3 INCH PE MAIN DUE TO SYSTEM IMPROVEMENT ALL-MIX REPLACE METER, ~EGUL.AllON AND ASSOCIATED STATION PIPING DUE TO SYSTEM IMPROVEMENT ALL-MIX
COMMERCIAL INST ALL METER AND REGULATION DUE TO CUSTOMER GROWTH OR INDUSTRIAL ~NSTALl 483 FEET OF 2 lNCH POLY MAIN DUE TO CUSTOMER CDMMERCJAL GROWTH OR INDUSTRIAL INST ALL 1260 FEET OF 2 INCH POLY MAIN DUE TO CUSTOMER COMMERCIAL GROWTH OR INDUSTRIAL INSTALL 950 FEET OF 2 INCH POLY AND 14 SERVICES DUE TO CUSTOMER GROWTH RESIDENTIAL
INSTALL 10.370 FEET OF 6 INCH P<lLY. 3940FEETOF 4 INCHPDLY AND 2 REGULATOR STATIONS DUE TO SYSTEM IMPROVEMENT ALL-MIX INSTALL 230 FEET OF 2 INCH POLY AND 2 SERVICES QUE TO CUSTOMER GROWlH RESIDENTIAL
COMMERCIAL INSTALL LARGE VOLUME METER DUE TO CUSTOMER GROWTH OR INDUSTRIAL PURCHASE OFFICE FURNITURE FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE lWO LINE LOCATORS FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX INSTALL 10 FEET OF 2 INCH POLY MAIM AND 1 SERVICE(S) DUE TO CUSTOMER GROWTH RESIDENTIAi. INSTALL 1532 FEET OF 2 INCH POLY MAIN AND 3 SERVICE($) DUE COMMERCIAL TO CUSTOMER GROWTH DR INDUSTRIAL lNSTALL3400 FEET OF 2INCH POLY, 52 SERVICES AND 1480 FEET OF 4 INCH POLY MAIN DUE TO CUSTOMER GROWTH RESIDENTIAL INSTALL 2,900 FEET OF 2 INCH POLY AND 41 SERVICES DUE TO CUSTOMER GROWTH RESIDENTIAL
COMMERCIAL INSTALL 3M ROOTS METER QUE TO CUSTOMER GROWTH DR INDUSTRIAL INSTALL272 FEET OF 4 INCH PDLYMAIN, INSTALL490 FEET OF 2 INCH POLY MAIN, AMD 22 SERVICE($) DUE TO CUSTOMER GROWTH RESIDENTIAL INST ALL 300 FEET OF 2 INCH POLY MAIN AND 1 SERVICE( SJ PUE TO CUSTOMER GROWTH RESIDENTIAL
WTXA.ddltlcm5: Page 10of98
DATE PLACED EN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWJH SEPTEMBER - 2016
030 TEXAS DIVISION GROWTH OCTOBER - 2016
030 TEXAS DIVISION GROWTH OCTOBER - 2016
030 TEXAS DIVISION GROWTH SEPTEMBER-2016
030 TEXAS DIVISION GROWTH AUGUST - 2016
030 TEXAS DIVISION GROWTH SEPTEMBER - 2016
030 TEXAS DIVISION GROWTH SEPTEMBER- 2016
030 TEXAS DIVISION GROWTH DECEMBER- 2.01-6
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030TEXAS DIVISION GROWJH SEPTEMBER - 2016
030 TEXAS DIVISION GROWJH DECEMBER~ 2016
030 TEXAS DIVISION GROWTH OCTO!IER - 2016
030 TEXAS DIVISION GROWJH SEPTEMBER- 2016
030 TEXAS DIVISION GROWTH OCTO!lER - 201$
030 TEXAS DIVISION GROWTH SEPTEMBER- 201.fi
030 TEXAS DIVISION GROWTH SEPTEMBER - 2016
030 TEXAS DIVISION EQUIPMENT OCTOBER - 2016
030 TEXAS DIVISION STRUCTURES DECEMBER-2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
0'30 TEXAS DMSION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION EQUIPMENT SEPTEMBER - 2016
030TEXAS DIVISION GROWTH OCTOBER y 2{)16
030 TEXAS DIVISION PUBLIC IMPROVEMENTS SEPTEMBER -2016
030 TEXAS DIVISION GROWTH SEPTEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH OCTOBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION STRUCTURES SEPTE.MBE:R - 2016
030 TEXAS DIVISION GROWTH 01::.CE:.MBER a 2016
030 TEXAS DIVISION EQUIPMENT OCTOBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER- 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER· 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030TEXAS DIVISfON GROWTH DECEMBER - 2<l16
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH OCTOBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER • 2016
030 TEXAS DIVISION GROWTH OCTOBER - 201$
030 TEXAS DIVISION EQUIPMENT OCTOBER - 2016
030 TEXAS DIVISlON EQUIPMENT OCTOBER- 2016
030 TEXAS DIVISION GROWTH SEPTEMBER - 2016
030TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER- 2016
030 TEXAS DlVISION GROWTH DECEMBER- 2016
030 TEXAS DIVISiON GROWTH DECEM!!ER - 2016
LINE ALl.OCATED NO. PROJECT NUMBER CoST(1l cosr
426 030.40872 1133) 1133)
427 030.40879 5.510 5.510
428 030.40888 41,001 41,001
429 030.40912 30.2Sdl 30.286
430 030.40920 1,958 1,958
431 030.40937 78,349 78,349
432 a:m-40953 1,805 1,805
433 030.40997 5,000 6,008
434 030-41015 56,028 56,026
435 030.41028 28,42S 26,428
436 030.41045 8,064 8,064
437 030.41067 2.222 2,222
438 030.41075 11,271 11,271
439 030.41076 8.240 8,240
440 030.41079 2,986 2,986
441 030,41084 15.835 15,83fi
442 030.41087 21,387 21,387
443 030.41097 36.722 36,722
444 030.41103 28,232 28,232
445 030.41107 44,313 44.313
446 030.41110 4,155 4,155
447 030.41112 7,173 7,173
448 030.41118 1,630 1,630
449 030.41128 557,516 557,516
450 030.41130 10,260 10,280
451 030.41133 12,703 12,703
452 030.41135 12,553 12,553
453 030.41148 665,500 665,500
454 030.41151 13,0B2 ,3,082.
455 030,41154 8,186 8,166
456 030.41155 B,237 8,237
457 030,41157 25,623 25,623
458 030.41158 61,973 61,973
459 030.41160 13,427 13,427
460 030.41161 11,767 11,767
461 030.41162 12,137 12,137
462 03-0.41164 19,251 19,251
463 030.41158 372 372
464 030.41170 24,346 24,346
465 030.41172 7,330 7,330
466 030.41174 35,244 35,244
467 030.41177 1,844 1,644
488 030.41179 2,160 2,160
469 030.41180 2,105 2,105
470 030.41181 2,432 2,432
471 030.41182 2,B27 2,827
472 030.411;86 6,852 6,852
473 030.41187 22,347 22,347
474 030.41192 11.182 11.182
475 030.41194 7,241 7,241
416 030.41203 103,005 103,655
ATMOSENERGV CORPOllATION, WESTTEXAS DIVISION INTERIM COST RECOVERY ANO RATE ADJUSTMENT REPORT
PROJJ;Cf REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED To CUSTOMERS PUBLIC USE IN CALENDAR VEAR 2016 (21 BENEFITED
INSTALL 356 FEET OF 2 INCH STEEUPOL Y MAIN DUE TO CUSTOMER GROWTH RESIDENTIAL INSTALL 405 FEET OF 2 INCH POLY MAIN AND2 SERVICES DUE TO CUSTOMER GROWTH RESIDENTIAL INSTALL 2200 FEET DF 6 INCH POLY MAIN AND 1 SERVICE{S) DUE COMMERCIAL TO CUSTOMER GROWTH OR INDUSTRIAL INSTALL 1965 FEET OF 2 INCH POLY MAIN AND 21 SERVICE( SJ DUE TO CUSTOMER GROWTH RESIDENTIAL INSTALL 450 FEET OF 2 INCH POLY MAIN AND ONE SERVICE DUE COMMERCJAL TO CUSTOMER GROWTH OR INDUSTRJAL INSTALL 1160 FEET OF6 INCH AND 1700 FEET OF 4 INCH POLY COMMERCIAL DUE TO CUSTOMER GROWTH CR INDUSTRIAL PURCHASE PIPE CUTTERS S TO 8 INCH FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX
INSTALL257 FEET OF 4 INCH POLY MAIN AND RETIRE 152 FEET OF 3 INCH STEEL MAIN OUE TO SYSTEM IMPROVEMENT ALL-MIX INSTALL952 FEET OF 4 INCH POLY MAIN, INSTALL672 FEET OF 2 INCH POLY MAIN AND 37 SERVICE(S) DUE TO CUSTOMER GROWTK RESIDENTIAL INSTAl.L 1250 FEET OF 2 INCH POLY MAIN AND 18 SERVICE{S) DUE TO CUSTOMER GROWTH RESIDENTIAL PURCHASE CALISRATION EQUIPMENT FOR USE SY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE ONE CONCRETE SAW fOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 1 MILLER BOBCAT 225 WELDER FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL- MIX PURCHASE 2 SETS Of NO BLOW LOCKSTOP CHANGERS FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 2 SINGLE AXLE CIM TRAILER FOR USE BY WEST TEXAS DIV!SION EMPLOYEES ALL-MIX PURCHASE 6 HYDRAULIO GREASE GUNS FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 3 GPS INTERRUPTERS FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE TABLE AND CHAIRS FOR AMARILLO TRAINING ROOM FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASES ELECTRO FUSION MACHINES FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 1 HEAVY DUTY COIL PIPE DISPENSING TRAILER FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 1 PIPE LOCATOR FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCKAsE 1 CONCRETE SAW FOR USE BY WEST TEXAS DlVISION EMPLOYEES Al.L-MIX PURCHASE 2 GAS DETECTORS FDR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PlJRCHASE PICARRO LEAK DETECTION EQUIPMENT TO ENHANCE SENSITIVITY OF LEAK SURVEYS FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL· MIX PURCKASE 4 SENS IT LEAK DETECTION UNITS FOR USE BY WEST TEXAS DMSION EMPLOYEES ALL-MIX PURCHASES REPLACEMENT SENSITS FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PERMANENT REPAIR !VIPER SKlN) APPLIED DUE TO SYSTEM INTEGRITY ALL- MIX
PURCHASE 2 INCH THROUGH 10 INCH TD WiLLIAMSCN PLUGGING EQUIPMENT FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 2 REMOTE SQUEEZE TOOLS FOR USE BY WEST TEXAS DIVISION EMPLOYEES /\LL-MIX PURCHASE 4" SHORT STOP TAPPING EQUIPMENT PACKAGE FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL· MIX PURCHASE 2" SHORT STOP PLUGGING EQUIPMENT PACKAGE FOR USE BY WEST TEXAS DIVISION EMPLOYEES /\LL-MIX PURCHASE 6 REMOTE SQUEEZE TOOLS FOR 314" TO 2'' PIPE FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 1 VAPOR EXTRACTION UNIT !VEU), VEU TRAILER, AND VEU KIT WITH PROBES AND HOSES FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 2 TINKER RllSOR APS HOLIDAY DETECTORS FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 1 HOLIDAY DETECTOR FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 4 3/4 TO ~· MUELLER NO BLO STOPS FOR GASEOUS ATMOSPHERE SAFETY FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 5 MUELLER K-17010 NO BLO VALVE CHANGERS FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX INSTALL COMMUNICATION PACKAGE DUE TO SYSTEM IMPROVEMENT ALL· MIX PURCHASE 3 MISC. MFRS LINE LOCATORS FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL- MEX PURCHAsE 1 OOOROMETER FOR USE BY WEST TEXAS DIVISION EMP!.OYEES ALL- MIX PURCHASE 1 ODOROMETER FORUS'E BY WEST TEXAS DIVIS!ON <:MP!.OYEES ALL-MIX PURCHASE ERX PRESSURE RECORDER FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 1 GAS DETECTORS FOR USE BYWESTTEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 1 THICKNESS GAUGE FOR USE BY WEST TEXAS DIVISION EMPLOYEES All-MIX PURCHASE 1 SENSIT GAS DETECTOR FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 1000 :POUND PRESSURE GAUGE FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHAsE 1 3M DYMATE!. 2550 LOCATOR FOR USE BY WEST TcXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 2 INFLATABLE SHORING DEVICES FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX PURCHASE 2 NO BLOW VAL VE CHANGERS FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MlX
PURCHASE ONE LED BRICK LIGHT WITH QUAD POD, ADAPTER ANO MOUNT FOR USE BY WEST TEXAS DIVISION EMPLOYEES ALL-MIX
INSTALL 6127 FEET OF 2 INCH POLY PIPE WITH 25 SERVICES, METERS, AND LOOPS DUE TO SYSTEM IMPROVEMENTS ALL- MIX
wnc: Addltlom;: Page 11 ot9B
DATE PlACEO IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION GROWTH SEPTEMBER - 2016
030 TEXAS DIVISIDN GROWTH OCTOBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 201fl
030 TEXAS DIVIS~ON GROWTH DECEMBER • 2016
030 TEXAS DMSION GROWTH DECEMBER· 2016
030TEXAS DIVISION GROW!1" DECEMBER · 2016
030 TEXAS DIVISION EQUIPMENT NOVEMBER-2016
030 TEXAs DIVISION PUBLIC IMPROVEMENTS DECEMBER · 2016
030 TEXAS DIVISION GRCWTI-1 DECEMBER - 2016
030 TEXAS DIVISIOr./ GROWTH DECEMBER· 2016
080 TEXAs DIVISION EQUIPMENT NOVEMBER -2016
030 TEXAS DIVISION EQUIPMENT DECEMBER~ 2016
030 TEXAS DIVISION EQUJPMENT DECEMBER -2016
030 TEXAS OIV!SION EQUIPMENT NOVEMBER ~ 2016
030 TEXAS DIVISION EQUIPMENT NOVEMBER - 2016
030 TEXAS DIVISION EQUIPMENT DECEMBER~ 2016
030 TEXAS OMS ION EQUIPMENT DECEMBER -2016
030 TEXAS DMSION EQUIPMENT DECEMBER~ 2016
030TEXAS DIVISION EQUIPMENT DECEMBER - 2016
030 TEXAS DIVISION EQUIPMENT DECEMBER - 2016
030 TEXAS DIVISION EQUIPMENT DECEMBER-2016
030 TEXAS DIVISION EQUIPMENT DECEMBER - 2016
030 TEXAS DIVISION EQUIPMENT DECEMBER. - 2016
030 TEXAS DIVISION EQUIPMENT DECEMBER-2016
030 TEXAS DIVISION EQUIPMENT DECEMBER-2016
030 TEXAS DIVISION EQUIPMENT DECEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - :2016
030 TEXAS DIVISION EQUIPMENT DECEMBER- 2016
030 TEXAS DIVISION EQUIPMENT DECEMBER-2016
030 TEXAS DIVISION EQUIPMENT DECEMBER- 2016
030 TEXAS DIVISION EQUIPMENT DECEMBER- 2016
030 TEXAS DIVISION EQUIPMENT SEPTEMBER - 2016
030TEXAS DIVISION EQUIPMENT SEPTEMBER - 2016
030TEXAS DIVISION EQUIPMENT SEPTEMBER - 2016
030 TEXAs DIVISION EQUIPMENT DECl::MBER • 2016
030 TEXAS DIVISION EQUIPMENT SEPTEMBER -2016
030 TEXAS DIVISION EQUIPMENT SEPTEMBER· 2016
030 TEXAS DIVISION SYSTEM IMPROVEMEl>ITS DECEMBER - 2016
030 TEXAs DIVISION EQUlPMENT DECEMBER -2016
030 1EXAS DMSlON EQUIPMENT DECEMBER - 2016
030 TEXAS DIVISION EQUIPMENT bEC:~MBER • 2016
030 TEXAS DIVISION EQUIPMENT DECEMBER -:2016
030 TEXA.S DMSION EQUIPMENT Di:::CEMBER • 2016
030 TEXAS DIVISION EQUIPMENT DECEMBER - 2016
030TEXAS DIVISION EQUIPMENT DECEMBER • 2016
030TEXAS DIVISION EQUIPMEN7 DECEMBER - 2016
030 TEXAS DIVISION EQUIPMENT SEPTEMBER-2016
030 TEXAS DIVISION EQUIPM!ONT OCTOBER • 2016
030 TEXAS DIVISION EQUIPMENT NOVEMBER· 2016
030 TEXAS DIVISION EQUIPMENT OOTOBER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER-2016
LINE ALLOCATED NO. PROJECT NUMBER cOST(1) COST
477 030.41207 134.234 134,234
478 030.41221 2.355 2,355
479 030.41226 3.206 3,20B
460 030.41335 31,021 31,021
481 030.41372 150.845 150.845
462 030.41374 (165) 1165
463 030.41402 5.481 5.481
484 030.41414 11.112 11,112
485 030.41420 677 677
486 030.41422 952 952
467 030.41443 9,654 9.654
486 030.41446 692 692
469 030.41447 BOB 608
490 030.41448 10.453 10.453
491 030.41454 63,175 B3,175
492 030.41456 11.357> (1,357)
493 030.41545 113,244 113,244
494 030.41551 111.5991 /11,599\
495 030-41553 3.668 3,668
496 030.41554 4.514 4.514
497 030.415154 32.513 32,513
498 030.41581 2.012 2.012
499 030.41589 13.1451 (3.1451
500 030.41599 5.930 o.930 501 030.41654 7,370 7.370
502 030.41676 27,642 27.642
503 030.41682 185,516 185.516
504 030.41710 4,548 4.548
505 030.41713 2,976 2.976
506 030.41726 1,099 1,099
507 030.41730 113.811 113,811
508 030.41751 9,647 9,647
509 030.41777 18,5.20 18,520
510 0'30.41786 6,870 6,870
511 030.41795 (7,007 (7,0071
512 030.41803 15.849 15,849
513 030.41804 124,488 124,486
514 030.41808 42,458 42.458
515 030.41846 (5,852) (5,8521
516 030.41855 51.881 51.881
517 030-41876 21,882 21,882
518 030.41895 6,673 6.673
019 030.41908 5,777 5,777
520 030.41919 10,671 10.671
521 030-41933 59,291 59.291
522 030.41940 3,717 3.717
523 o:m.42229 5,;253 5,253
TOTAL WEST TEXAS -All OTHER DJVISIONS
ADDITIONS 524 (LN. 58-LN. 5231 25.021.891 25,021,891 525
526 527 ADDlnONS - TEXAS RULlr 8.209 PROJECTS
528 030.23449 117.4631 117,463
529 030.23475 45 45
ATMOS ENER:GV CORPORAllON, WfST TEXAS DIVISION INTERIM COST RECOVERY ANO RATE ADJUSTMENT R£PORT
PROJECT REPORT cY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 1185FEET OF 4 INCH POLY MAJN. INSTALL4300 FEET OF 2 INCH POLY MAIN. AND 40 SERVICE(S] DUE TO CUSTOMER GROWTH PURCHASE AIR COMPRESSOR FOR BS OPERATIONS AREA FOR USE BY WEST TEXAS DIVISION EMPLOYEES REPLACE DISPLACEMENT METER WITH A 3M ROOTSMETER DUE TO SYSTEM IMPROVEMENTS INSTALL REGULATION AT MEASUREMENT AND REGULATOR STATION DUE TO SYSTEM IMPROVEMENT PURCHASE FFE FOR LEVELLAND BUILDING DUE TO BUllDING AND LAND IMPROVEMENTS INSTALL COMMUNICATION PACKAGE DUE TO SYSTEM IMPROVEMENT INST ALL 4633 FEET OF 2 INCH POLY WITH 12 SERVICES DIJE TO CUSTOMER GROWTH INST ALL 700 FEET OF 2 INCH POLY MAIN WITH 1 SERVICE DUE TO CUSTOMER GROWTH INSTALL 3M ROOTS METER SETTING DUE TO CUSTOMER GROWTH INST ALL 499 FEET OF 2 INCH POLY MAJN AND 1 SERVICE DUE TO CUSTOMER GROWTH PURCHASE NEW FLAME PAK FOR USE BY WEST TEXAS DIVISION EMPLOYEES INSTALL NEW LARGE VOLUME METER sET DUE TO CUSTOMER GROWTH INSTALL NEW LARGE VOLUME METER SET DUE TO CUSTOMER GROWTH BUILD 10 X 20' STORAGE BUILDING WITH WALK IN DOOR DUE TO BUILDING IMPROVEMENTS INSTALL 4110 FEET OF 2 INCH POLY WITH 19 SERVICES DUE TO CUSTOMER GROWTH INSTALL 550 FEET OF 2 INCH POLY AND 1 SERVICE DUE TO CUSTOMER GROWTH INSTALL SECURITY FENCE AT LARGE IP sTATION IN AMARILLO DUE TO BUILDING AND LAND IMPROVEMENTS REPLACE 120 FT OF 3 INCH STEEL PIPE WITH 150 FEET OF 4 INCH PoLY DUE TO PUBLIC IMPROVEMENTS INSTALL 3M ROOTS METER SETTING DUE TO CUSTOMER GROWTH
INSTALL ROOTS METER SETIING DUE TO CUSTOMER GROWTH INSTALL 5805 FEET OR 4 INCH POLY. 1 SERVICE AND REGULATION AND RETIRE 4760 FEET OF 2 INCH POLY INSTALL 1,450 FEET OF 21NCHPOLYMAIN WITH 1 SERVICE DUE TO CUSTOMER GROWTH INSTALL97 FEET OF2 INCH POLY MAIN AND 1 SERVICE(S) DUE TO CUSTOMER GROWTH INSTALL 206 FEET OF 2 INCH POLY WITH ONE SERVICE DUE TO CUSTOMER GROWTH INSTALL 179 FOOT EXTENSION DUE TO CUSTOMER GROWTH INSTALL 1488 FEET OF 2 INCH POLY DUE TO CUSTOMER GROWTH PURCHAsE LAND FOR CONSTRUCTION OF LEVELLAND !IUILDING PUE TO BUILDING AND LAND IMPROVEMENTS INSTALL 389 FEET OF 2 INCH POLY WITH SERVICE DUE TO CUSTOMER GROwtH INSTALL 5M METER SETTING AND SERVICE DUE TO CUSTOMER GROWTH INSTALL NEW METER AND REGULATION DUE TO CUSTOMER GROWTH INSTALL 1440 FEET OF 4 INCH POLY AND 3170 FEET OF 2 INCH POLY WITH 69 SERVICES DUE TO CUSTOMER GROWTH INSTALL 330 FEET OF 2 INCH POLY WITH ONE SERVICE DUE TO CUSTOMER GROWTH INSTALL 1100 FEET 2 INCH POLY AND 9 SERVICES DUE TO CUSTOMER GROWTH INSTALL 60 FEET OF 2 INCH POLY AND ONE SERVICE DUE TO CUSTOMER GROWTH INSTALL 5M ROTARY METER SETTING DUE TO CUSTOMER GROWTH INSTALL 480 FEET OF 2 INCH POLY WrTH ONE SERVICE DUE TO CUSTOMER GROWTH INSTALL 4076 FEET OF 2 INCH POLY ANO 694 FEET OF 4 INCH POLY WITH 61 SERVICES DUE TO CUSTOMER GROWTH INSTALL 2570FEETOF2 INCHPOLY, 540 FEET OF 4 INCH POLY WITH 40 SERVICES DUE TO CUSTOMER GROWTH
INSTALL NEW METER SETIING DUE TO CUSTOMER GROWTH INSTALi- 3080 FEET OF 2 INCH POLY DUE TO CUSTOMER GROWTH INSTALL 520 FEET OF 4 ]NCH AND 500 FEET OF 2 INCH POLY MAIN AND ONE S'ERVICE DliE TO CUSTOMER GROWTI-1 INST ALL 250 FEET OF 1.25 INCH POLY DUE TO CUSTOMER GROWTH !NST ALL 1060 FEET 2 INCH POLY AND 2 SERVJCES DUE TO CUSTOMER GROWTl-1 INST ALL 700 FEET 2 INCH POLY WITH ONE SERVICE DUE TO CUSTOMER GROWTH INSTALL 2355 FEET OF 2 INCH POLY WITH 25 SERVICES DUE TO CUSTOMER GROWTH INST ALL 100 FEET OF 2 INCH POLY PIPE WITH ONE SERVICE DUE TO CUSTOMER GROWTH INSTALL 1035 FEET OF 4 INCH Pol Y DUE TO CUSTOMER GROWTH
INSTALL26'33 FEET OF 4 INCH POLY MAIN, INSTALL 20494 FEET OF 2 INCH POLY MAIN. RETIRE 31324 FEET OF VARIOUS STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX AddfUan5 Page 12 of 98
CUSTOMERS BENEFITED
RESIDENTIAL
ALL- MIX
ALL- MIX
ALL-MIX
#NIA
ALL-MIX
RESIDENTIAL
RESIDENTIAL
ALL-MIX COMMERCIAL
OR INDUSTRIAL
ALL· MIX COMMERCIAL
OR INDUSTRIAL COMMERCIAL
OR INDUSTRIAL
ALL-MIX
RESIDENTIAL COMMERCIAL
OR INDUSTRIAL
#NIA
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
RESIDENTIAL COMMIORCIAL
OR INDUSTRIAL
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
#NIA COMMERCIAL
OR INDUSTRIAL COMMERCIAL
OR INDUSTRIAL
ALL-MIX
ALL-MIX COMMERCIAL
OR INDUSlRIAL
RESIDENTIAL COMMERCIAL
OR INDUSTRIAL COMMERCIAL
OR INDUSTRIAL
ALL-MIX
ALL-MIX
RESIDENTIAL COMMERCIAL
OR INDUSTRIAL
RESIDENTIAL COMMERCIAL
OR INDUSTRIAL
RESIDENTIAL
RESIDENTIAL COMMERCIAL
OR INDUSTRIAL
RESIDENTIAL
RESIDENTIAL COMMERCIAL
OR INDUSTRIAL
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION GROWTH DECEMBER- 2016
030 TEXAS DIVISION EQUIPMENT SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER-201S
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER- 2016
030 TEXAS DIVISION STRUCTURES DECEMBER- 2016
030 TEXAS DIVISION SYSTEM lMPROVEMENTS DECEMBER- 2016
030 TEXAs DIVISION GROWTH DECEMBER- 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030TEXAS DIVISION GROWTH DECEMBER- 2016
030 TEXAS DIVISION GROWTH DECEMBER- 2016
030 TEXAS DIVISION EQUIPMENT NOVEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER· 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION STRUCTURES NOVEMBER· 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER • 2015
030 TEXAS DIVISION STRUCTURES DECEMBER - 2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS DECEMBER-2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER· 2016
030 TEXAS DIVISION SYsTEM IMPROVEMENTS DECEMBER -2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016 030 TEXAS DIVISION GROWTH DECEMBER- 2016
030 TEXAS DIVISION GROWTH DECEMBER - 20115
030 TEXAS DIVISION STRUCTIJREs DECEMBER- 2016
030 TEXAS DIVISION GROWTH DECEMBER - 20''!6
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
oao TEXAS DIVISION GROWTK DECEMBER· 2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH DECEMBER-2016
030 TEXAS DIVISION GROWTH DECEMBER- 2016
030 TEXAS DIVISfON GROWTH DECEMBER- 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2018
030TEXAs DIVISION GROWTH IJEC~MBER - 201B
030 TEXAS DIVlslON GROWTH DECEMBER - 201B
030 TEXAS DIVISION GROWTH DECEMBER • 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
030 TEXAS DIVISION GROWTH DECEMBER - 2016
0'30 TEXAS OlVISION GROWTH DECEMBER • 2016
030 TEXAS DIVISION GROWTH DECEMSER - 2016
030 TEXAS DIVlslON GROWTH DECEMBER~ 2016
030 TEXAS DIVISION SYSTEM INTEGRITY oc:::roal:.fi - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUM!IER COST{1)
530 030.23484 10
531 030.23493 4
532 030.23518 4
533 030.23520 ea
534 030.23909 (3)
535 03'J.23915 56
~ 000.23932 58
537 030.23937 11
538 030.23947 "" 539 03°'23948 62
040 030.23962 {221
541 030.23964 7
542 030.23970 35
543 030.23975 (391
544 030_23934 17
545 030.23997 47
546 030.24027 11651
547 030.24035 47
548 OaD.24045 3
549 030.24052 46
55(1 oao.24005 (45)
551 030.24077 21
552 030.24084 10
553 030.24086 4
554 030.2409-2 IS
555 030.24101 42
555 030.24104 12
557 030.24125 (16)
556 030.24143 as
559 030.24152 {31)
500 030.24153 47
561 030.24164 34
562 030_241as {421
563 000.24197 66
564 030,24199 49
565 030.24206 70
566 030.24212 9
567 030.24228 ao
ATMOS ENERGVCORPDRATION, WESTTEXAS DIVISION INU"l\IM con ~ECOVERYAND RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
ALLOCATED DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS COST PUBLIC USE IN CALENDAR YEAR 2015 {2]
INSTALL 76 FEETOf 3 INCH POLY MAIN. INSTALL 19FEHOF2 INCH POLY MAIN, RETIRE 76 FEET OF 3 INCH STEEL MAIN. AND RETIRE 19 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH
10 RAILROAD COMMISSION OF TEXAS RULE 8.209 REMOllE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD
4 COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
4 COMMISSION OF TEXAS RULE 8.200 INSTALL 35 FEET OF 4 INCH POLY MAIN AND RETIRE 3o FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
BB COMMISSION OF TEXAS RULE B.200 RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAllROAD
{3) COMM1SSION OF TEXAS RULE 8.209
INSTALL 20 FEET OF 6 INCH STEEL MAIN, RETIRE 20 FEET OF 6 INCH STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE
56 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 30 FEET OF 4 INCH STEEL MAIN. INSTALL 12 FEET OF 3 INCH STEEL MAIN, RETIRE 30 FEET OF 4 INCH STEEL MAIN, RETIRE 12 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH
58 RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
11 COMMISSlON OF TEXAS RULE 6.209 INSTALL 78 FEET OF 2 INCH POLY MAIN, RETIRE 78 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
89 RAILROAD COMMISSION OF TEXAS RULE 8.20B INSTALL 95 FEET OF 4 INCH POLY MAIN AND RETIRE 95 FEET OF 7 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
82 COMMISSION OF TEXAS RULE 6.209 INSTALL 150 FEET OF 2 INCH POLY MAIN. INSTALL 4o FEET OF 1.25 INCH POLY MAIN. AND RETIRE 200 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS
'22 RULE B.209 RETIRE 10 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
7 8.209 INSTALL 179 FEET OF 4 INCH POLY MAIN AND RETIRE 179 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
36 COMMISSION OF TEXAS RULE 8.200 INSTALL 30 FEET OF 2 INCH POLY MAIN AND RETIRE 30 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(39) COMMISSION OF TEXAS RULE B.209 lNST.ALL 20 FEET OF 2 INCH POLY MAIN, RETIRE :m FEET Of 2 INCH STEEL MAlN AND 1 SERVICE IN ACCORDANCE WITH
17 RAILROAD COMMISSION OFTEXAS RULE B.209 INSTALL 30 FEET OF 6 !NCH STEEL MAIN, RETIRE 30 FEET OF 6 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
47 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 240 FEET Of 2 INCH POLY MAIN AND RETIRE 240 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
11651 COMMISSION OF TEXAS RULE 8.209 INST ALL 15 FEET OF 2 INCH STEEL MAIN AND RETIRE 15 FEET OF 2 INCH STEEi. MAIN IN ACCORDANCE WITH RAILROAD
47 COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD
3 COMMISSION OF TEXAS RULE 8.209 INSTALL 100FEETOF2 INCH POLY MAIN, RETIRE 100 FEET OF2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH
46 RAllROAD COMMISSION OF TEXAS RULE 8.209 INSTALL250FEET OF2 INCH POLY MAIN AND RETIRE250 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
t4oJ COMMISSION OF TEXAS RULE B.209 INSTALL 192fEET OF2 INCH POLY MAIN. RETIRE 1"2 FEET Of STEEL MAIN. AND 2 SERVICES IN ACCORDANCE WITH RAil.ROAD
21 COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 2 INCH POLY MAIN, RETIRE 20FEET OF2 INCH SlEEL MAIN, AND 1 SERVICE IN ACCORDANCE Willi
10 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 168 FEET OF2 INCH POLY MAIN, INSTALL246FEET DF 1.25 INCH POLY MAIN, RETIRE 414 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION
4 OF TEXAS RULE 8.209 INSTALL 9 HJ;T OF 2 INCH POLY MAlN AND RETIRE 9 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAO
161 COMMISSION OF TEXAS RULE 8.209 INSTALL 6 INCH WELOOVER AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
42 8.209 ~NSTALL 5FEET OF2 INCH STEEL MAIN AND RETIRE 5 FEETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
12 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
1161 COMMISSION OF TEXAS RULE 6.209 INST ALL 40 FEET OF 2 INCH POLY MAIN AND RETiRE 40 FEET Of 1-25 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
36 COMMISSION OF TEXAS RULE 8-209
(311
47
34
'42'
88
49
70
9
30
REPAIR LEAK ON 4 INCH MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL31 FEETOF3 INCHSTEEL MAIN AND RETIRE 31 FEET OF a INCH STEEL MAlN IN ACCORDllNCEWITH RAILROAD COMMISSION OF TEXAS RUl-E 8,209 INSTALL 20FEET OF2 ~NCH POLY MA!NAND RET1RE.20 FEET OF2 INCH STEEL MAIN iN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8-200 INSTALL 5 FEET OF 6 INCH STEEL MAIN AND RETIRE 5 FEET OF 8 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.Z09 INSTALL 202 FEET Of 4 INCH POLY MAIN AND RETIRE 202 FEET OF 6 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAO COMMISSION OF TEXAS RULE 8.209 INST ALL 7 FEET OF 2 INCH STEEL MAIN AND RETIRE 7 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE Win-! RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
WTX Additions P<1gt:i 13 Df9.B
BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL"MIX
ALL-MIX
ALL-MIX
ALL" MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL· MIX
ALL-MIX
ALL-M!X
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL- MIX
OAT.E. P~CCD IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03'J TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
000 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAY"2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION sYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRlTI MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVIStON SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03'J TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAV-201B
030 TEXAS D!VlSlON SYSTEM INTEGRITY MAY-2016
030TEXASDIVISION SYSTEM INTEGRIIT MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
o:m TEXAS DJVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST{1)
568 030.24226 44
569 030.24247 5
570 030.24248 2
571 030.24250 2
572 030.24251 2
573 030.24260 6
574 030.24264 7
575 030.24267 63
576 030.24309 27
077 030.24315 15
578 030.24316 7
579 030.24333 15
580 030.24334 18
581 03-0.24360 179
582 030.24'362 179
583 030.24365 (72)
5B4 030.24369 17
585 030.24384 B
586 030.24390 85
587 030.24420 77
58B 030,24435 20
569 030.24441 (56
590 030.24443 35
591 030.24456 8,027
592 030.24473 13
593 030.24474 23
594 030.24478 63
595 030,24480 23
596 030.24488 14,594
597 030.24493 26
598 030.24504 14
599 030.24507 14
600 030.24510 1351
601 030.24526 111'
502 030.24529 1231
603 030.24536 30
604 030.24540 85
605 030.24544 90
606 030.24549 102
ATMOS ENERGVCORPOflA.TION, WES.T TEXAS DIVIS.ION INTERIM COST RECOVERY ANO RATE ADJUSTMENT REPORT
P~OJECT REPoRT CV 2016
ALLOCATED OESCmPTION OF COMPLETED PROJECTS DEDICATED TO COST PUBLIC USE IN CALENDAR YEAR 2016 {2}
RETIRE 2 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
44 8.209 !NSTALl 53 FEET OF 3 INCH POLY MAIN. RETIRE 53FEETOF3 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
5 RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE JN ACCORDANCE WITH RAILROAD
2 COMMISSION OF TEXAS RULE 8.209 INSTALL 40 FEET OF 2 INCH POLY MAIN AND RETIRE 40 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
2 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
2 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
ti COMMISSION OF TEXAS RULE 8.209 INSTALL 54 FEET OF 2 INCH POlVMAIN, INSTAll99 FEET Of 1.25 INCH POLY MAIN AND RETIRE 153 FEET OF 3 INCH AND 2 INCH STEEL MAIN IN ACCORDANCE wm1 RAILROAD COMMISSION OF
7 TEXAS RULE B.209 REPLACE 104 FEET OF 3 INCH POLY MAIN AND TWO SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
63 6.209. REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
27 COMMISSION OF TEXAS RULE B.209 INSTALL 105 FEET OF 2 INCH POLY MAIN AND RETIRE 105 FEET OF 3 INCH STEEL MAIN lN ACCORDANCE Wl1H RAILROAD
15 COMMISSION OF TEXAS RULE 8.209 INSTALL 189 FEET OF 2 INCH POLY MAIN, RETIRE 189 FEET OF 2 INCH STEEL MAIN. AND 3 SERVICES IN ACCORDANCE WITH
7 RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
15 COMMISSION Of TEXAS RULE B.209 !NSTALL20FEETOF2 ~NCH POLY MAIN AND RETIRE 20PEET OF2 lNCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
16 COMMISSION OF TEXAS RULE 8.209 INSTALL 118 FEETOF2 INCH POLY MAIN, RETIRE 118 FEETOF2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH
179 RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 35 FEET OF 4 INCH STEEL MAIN AND RETIRE 35 FEET OF 4 INCH STEEL MAIN DTAU IN ACCORDANCE WITH RAlLROAD
179 COMMISSION OF TEXAS RUL< 8,209 INSTALL 36 FEET OF 2 INCH STEEL MAIN AND RETIRE 36 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
!72) COMMISSION DF TEXAS RULE 8.209 INSTALL 13FEET OF4 INCH POLY MAIN AND RETIRE 13 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
17 COMMISSION DF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
6 COMMISSION OF TEXAS RULE 8.209 INSTALL 122 FEET OF 4 INCH POLY MAIN AND RETIRE 122 FEET OF 7 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
85 COMMISSION OF TEXAS RULE 8.209 RETIRE 175 FEETOF2 INCH STEEL MAIN AND 1 SERVICE DUE TO ENCROACHMENT IN ACCORDANCE WITH RAILROAD COMMISSION
77 OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
20 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
t56J COMMISSION OF TEXAS RULE 8.209 INSTALL 37 FEET OF 3 INCH POLY MAIN. RETIRE 37 FEET OF 3 INCH STEEL MAlN, AND 2 SERVICES IN ACCORDANCE WITH
35 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 16100 FEET OF 2 INCH POLY MAIN, RETIRE 16150 FEET OF 2 INCK STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
8,027 8.209
13
23
63
23
14,594
26
14
14
(35)
1111
(23)
30
85
90
102
INSTALL 170 FEET OF2 INCH POLY MAIN, RETIRE 170 FEET OF 2 INCH STEEL MAIN, ANO 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALl274 FEET OF 2 INCH POLY MAIN, RETIRE 177 FEET OF 2 INCH STEEL MAIN, AND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 70 FEET OF 4 INCH POLY MAIN. RETIRE 70FEET OF6 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 27 FEET OF 4 INCH POLY MAIN, RETIRE 27 FEET OF 4 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTAU. 9808FEET DF 4 INCH POLY MAlN. INSTALL 15668 FEET OF 2 INC!l POLY MAIN, RETIRE 25467 FEET OF 6 INCH, 4 INCH. AND 3 INCH STEEL MAIN, AND 378 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSJON Of TEXAS RULE a.209 INST AU 25 FEET OF' 4 INCH POLY MAIN, RET~RE 25 FEET OF S fNCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAIL.ROAD COMMISSION OF TEXAS RULE B.209 INSTALL 60 FEETOF2 INCK POLY MAIN, RETIRE GO FEET OF 2 INCH STEEL MAIN. AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 42 FEET IF 2 INCH POLY MAIN ANO RETIRE 42 FEET IF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 57 FEET OF 2 INCH POLY MAIN AND RETIRE 47 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WlTH RA!LROAD COMMISSION OF TEXAS RULE 8.209 INSTALL33 FEETOF2 INOH POLY MAIN AND RETIRE33 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 229 FEET Of 2 INCH STEE!. MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL64 FEET OF4 INCH POLY MAIN AND RETIRE64 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 19 FEET OF 6 INCH STEEL MAIN AND RETIRE 1H FEET OF 5 INCH STEEL MAIN IN ADCORDANCE WITH RAilROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 45 FEET OF 6 INCH STEEL MAIN AND RETIRE 45 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTXA,ddillOM!S.
Page 14of 98
CUSTOMERS BENEFITED
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL- MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL- MIX
ALL- MIX
All.-MIX
ALL-MIX
ALL-MIX
All-MIX
DATE PLACcu <N GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201-B
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-201B
O:ID TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 lEXAS OIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
o:io TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITI' MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VJSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST(1l
607 030.24554 22
608 030.24557 30
609 030.24567 1
610 030.24566 22
611 030.24569 27
612 030.24570 25
613 030.24566 13
614 030.24594 22
615 030.24609 38
616 030.24615 57
617 030.24619 22
618 030.24626 (136)
619 030.24639 480
620 030.24645 (591
621 030.24646 244
622 030.24652 176
623 030.24654 14
624 000.24665 13
625 030.24668 [227
626 030.24669 (48
627 030.24672 16
626 030.24676 37
629 030.24707 217
630 030.24718 12•
631 030.24724 {104}
632 030.24727 4
633 030.24810 (110
634 030.24817 10,516
635 030.24824 39
636 030.24a2s 2
637 030.24826 21
sa8 030.24828 16
639 o:m.24aao 28
640 030.24831 56
641 030.24832 129
642 030.24833 73
ATMOS ENERGY CORPORATION, WEST TEXAS OMS ION lr.lTERtM COST RECOV!EIW ANO RATE ADJUSTMENT REPORT
PROJECT REPORT C''I 2016
ALLOCATED DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS COST PUBLIC USE IN CALENDAR YEAR 2016 (2)
REPLACE 1 SERVICE IN ACCORDANCE Willi RAILROAD 22 COMMISSION Of TEXAS RULE B.209
INSTALL 29 FEET Of 2 INCH POLY MAIN AND RETIRE 29 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
30 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
1 COMMISSION OF TEXAS RULE 8.209 INST ALL 7 FEET OF 6 INCH POLY MAIN AND RETIRE 7 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
22 COMMISSION OF TEXAS RULE 8.209 INSTALL 10FEETOF 0.75 INCH POLY SERVICE AND RETIRE 10 FEET OF 1 INCH STEEL SERVICE IN ACCORDANCE WITH
27 RAILROAD COMMISSION OF TEXAS RUl-E 8,209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
25 COMMISSION OP"lE:XAS RULE 8.209 INSTALL 43FEET OF 3 INCH POLY MAIN AND RETIRE 4HEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
13 COMMISSION OF TEXAS RULE 8.209 INSTALL 11 FE.ET OF3 ~NCH POLY MAIN AND RETIRE:a FEET OF 3 INCl1 STEEL MAIN IN ACCORDANCE WITH RAILROAD
22 COMMISSION OF TEXAS RULE 8.209 RETIRE 78 FEET OF 4 lNCH STEEL MAIN DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF
38 TEXAS RULE 8.209 INSTALL 19FEET OF 3 INCH POLY MAIN AND RETIRE 19 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
57 COMMISSION OF TEXAS RULE 8.209 RETIRE 2 SERVICES IN ACCORDANCE WITH RAILROAD
22 COMMISSlON OF TEXAS RULE S.2.09 INSTALL 18 FEET OF 2 INCH OF STEEL MAIN AND 148 FEET OF 2 INCH OF POLY MAIN AND RETIRE 157 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS
1136> RULE8.209 INSTALL 37 FEET OF 4 !NCH POLY MAIN, INSTALL 85 FEET OF 2 INCH POLY MAIN, INSTALL 21 FEET OF 8 INCH STEEL MAIN, INSTALL 1 FEET OF 4 INCH STEEL MAIN, INSTALL 5 FEET OF 3 INCH STEEL MAIN, RETIRE 21 FEET OF B INCH STEEL MAIN, RETIRE 44 FEET OF 4 INCH STEEL MAIN, RETIRE 5 FEET OF 3 INCH STEEL MAIN, AND RETIRE 85 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
480 8.209 INSTALL61 FEETOF2 INCH POLY MAIN, RETIREB1 FEETOF2 INCH STEEL MAlN, AND 2 SERVICES IN ACCORDANCE WITH
(59} RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 14 1 INCH STEEL SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF
244 TEXAS RULE 8.209 INST ALL 2690 FEET OF 2 INCH POLY MAIN, RETIRE 2690 FEET OF 2 INCH STEEL MA!N, AND ASSOCIATED SERVlCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
178 B.209 INSTALL 14 FEET OF 3 INCH STEEL MAIN AND RETIRE 14 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
14 COMMISSION OF TEXAS RULE 6.209 RETIRE 1.25 INCH SERVICE DUE TO SYSTEM INTEGRfTY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
13 8.209 INSTALL 30 FEET OF 4 INCH STEEL MAIN, INSTALL 27FEETOF 4 INCH POl.YMAIN, RETIRE57 FEETOF4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
1227> 8.209 INSTALL 27 FEET OF 2 INCH POLY MAIN AND RETIRE 27 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
{48) COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
16 B.200 INSTALL 430 FEET OF 1 INCH POLY MAIN, RETIRE 967 FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH
37 RAILROAD COMMISSION DFTEXAS RULE 8.209 INSTALL 278 FEET OF 4 INCH POLY MAIN AND RETIRE 27SFEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
217 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
128\ COMMISSION OF TEXAS RULE 6.200 INSTALL 199 FEET OF 4 INCH POLY MAIN, INSTALL 277 FEET OF3 INCH POLY MAIN, AND RETIRE 475 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
(104) 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
4 COMMISSION OF TEXAS RULE 8_209 INSTALL 110 FEET OF2 INCH STEEL MAIN AND 104 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(1101 COMMISSION OF TEXAS RULE 8.209 INSTALL 3466FEET OF2 INCH POLY MAIN, RETIRE 3100 FEET OF 2 INCH PVC MAIN, AND 35 SERVICES IN ACCORDANCE WITH
10,.516 RAILROAD COMl>llSSION OF TEXAS RULE 8.209 INST ALL 11 FEET OF 2 INCH STEEL MAIN, RETIRE 11 FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH
39 RAl.LROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
2 COMMISSION OF TEXAS RULE 8.209
21
16
28
58
129
73
INSTALL 17 FEET Of 6 INCH STEEL MAIN AND RETIRE 17 FEET OF 6 INCH STEEL MA!N IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 15 FEET OF 4 INCH POLY MAIN, RETIRE 15 FEET OF 4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISS~ON OF TEXAS RULE 6.209 INSTALL 19 FEET OF 2 INCH POLY MAIN ANO RETIRE 19 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
RETIRE 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 112 FEET OF 4 INCH POLY MAIN AND RETIRE 112 FEET OF B INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 41 FEETOF2 INCHPOLY MAIN, RETIRE 41 FEET OF 2 INCH STEEL MAIN, ANO 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
wnc Additions Page 1:5 ofgg
BENEFITED
All-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-Ml)(
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
All- MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXA5 DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSJON SYSTEl>I INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTIOGRfTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXA5 DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SY8TEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE No. PROJECT NUMBER COST(1]
643 030.24834 36
644 030.24836 87
645 030.24837 (66)
646 030.24849 161
647 030.24850 23
646 030.24851 20
649 030.24857 17
650 030.24660 9
651 030.24062 2
652 030.24664 22
653 0'30,24B71 38
654 030.24874 22
655 030.24876 21
656 030.24888 15
657 030.24893 16
658 oao.24a94 (2981
659 030.24~96 (431
660 o:m.24a97 67
661 030.24920 12551
662 030.24924 (101
663 030.24925 1136)
664 030.24926 (581
665 030.24930 (801
666 030.24931 62
667 030.24940 {391)
668 030.24956 46
669 030.24961 (100)
670 030.24962 12
671 030.24973 f47\
672 000.24974 164
673 030.24976 (41)
674 030.25006 (111)
675 030.25012 5
676 030.25016 119
671 030.25053 11821
678 030.25081 180
679 030.25082 94
660 030.25003 115
681 030.25088 9
682 030.25089 6
ATMOS ENERGY CORPOAATION, WEST TEXAS OIViSION INTEruM COST RECOVERY ANO RA. TE ADJUSTMENT REPORT
PROJECT :Rf PORT CV 2016
ALLOCATED DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS COST PU8UC USE IN CALENDAR YEAR 2018 (2)
INSTALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
38 COMMISSION OF TEXAS RULE 8.209 INSTALL 10 FEET OF 3 INCH STEEL MAIN AND RETIRE 10 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
87 COMMISSION OF TEXAS RULE 8.209 INSTALL 50 FEET OF 2 INCH POLY MAIN AND RETIRE 60 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
i66J COMMISSION OF TEXAS RULE B.209 INSTALL 44 FEET OF 4 INCH POLY MAIN AND RETIRE 44 FEET OF 4 INCH STEEi- MAIN IN ACCORDANCE WITH RAILROAD
151 COMMISSION OF ToXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
23 COMMISSION OF TEXAS RULE B.209 INSTALl26 FEET OF 2 INCH STEEL MAIN AND RETIRE 26 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
20 COMMISSION OF TEXAS RULE 8.209 INSTALi- 12 FEET OF 2 INCH STEEL MAIN, RETIRE 12 FEET OF 2 INCH STEEi- MAIN. AND 1 SERVICE IN ACCORDANCE WITH
17 RAILROAD COMMISSION OF TEXAS RULi' 8.209 INST ALL 7 FEET OF 2 INCH STEEL MAIN, RETIRE 7 FEET OF 2 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD
9 COMMISSION OF TEXAS RULE B.209 REMOVE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD
2 COMMISSION OF TEXAS RULE 8.209 INSTALL 16 FEET OF 3 INCH POLY MAIN. RETIRE 16 FEET OF3 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH
22 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 10 FEET OF 2 INCH STEEL MAIN, RETIRE 110FEET DF2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
3B RAILROAD COMMISSION OF TEXAS RULE B.20Q INSTALL 20 FEET OF 4 INCH POLY MAIN AND RETIRE 20 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
22 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
21 COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET OF2 !NCH STEEL MAIN AND RETIRE 6 FEETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
15 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
16 COMMISSION OF TEXAS RULE 8.209 INSTALL 97 FEET OF 6 INCH POLY MAIN AND RETIRE 99 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAil-ROAD
j2981 COMMISSION OF TEXAS RULE 8,209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
1431 COMMISS!ON OF TEXAS RULE S.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD
67 COMMISSION OF TEXAS RULE 8.209 INST ALL 48 FEET OF 10 INCH STEEL MAIN ANO RETIRE 48 FEET OF 10 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
{255) COMMISSION OFTEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITfl RAILROAD
110) COMMISSION OF TEXAS RULE 8.209
lNSTALL 100 FEETOF2 INCH POLY MAIN, RETIRE 100 FEETOF2 INCH STEEL MAIN AND ASSOCIATED SERVICES JN ACCORDANCE
(1$) WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 36 FEET OF 2 INCH STEEL MAIN, RETiRE 36 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH
!58) RAILROAP COMMISSION DF T<XAS RUl-E 8.209 INSTAl.L 10 FEET OF6 lNCH STEEL MAIN AND RETlRE 10 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WtTH RAILROAD
(BO' COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD
52 COMMISSION OF TEXAS RULE 8.209
INSTALL68 FEET OF 3 INCH POLY MAIN, INSTALL65 FEET OF 2 INCH POLY MAIN, RETIRE SB FEET OF 4 INCH STEEL MAIN, RETIRE 65 FEET OF 3 INCfl STEEL MAIN, AND 1 SERVICE IN ACCORDANCE
1391) WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 32 FEET OF 21NCH STEEL MAIN AND RETIRE 32 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE W!TH RAILROAD
46 COMMISSION OF TEXAS RULE 8.209 INSTALL 15 FEET OF 3 INCH POLY MAIN. RETIRE 15 FEET OF 3 INCH STEEL MAIN, AND RETIRE 1 REGULATOR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
(100) 8.209 INSTALL 40 FEET OF 2 INCH POLY MAIN AND RETIRE 40 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAP
12 COMMISSION OF TEXAS RULE 8.209 INSTALi- 18 FEET OF 2 INCH STEEL MAIN AND RETIRE 18 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
[47) COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCH STEEL MAIN AND RETIRE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(541 COMMISSION OF TEXAS RULE B.209 INSTALL 5 FEET OF 2 INCi-i STEEL MAIN AND RETIRE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
1411 COMMISSION OF TEXAS RULE 8.209 INSTALL 98 FEET OF 2 INCH POLY MAIN, RETIRE 98 FEET OF 2 INCH STEEL MAIN, AND 1 .SERVICE IN ACCORDANCE WlTH
11111 RAILROAD COMMlSSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
5 COMMISSION OF TEXAS RULE 8,209 REPLACE 1 SERVICE IN ACCORDANCE W~TH RAILROAD
119 COMMISSION OF TEXAS RULE 8.209 INSTALL 245 FEET OF 2 INCH POLY MAIN AND RETIRE 245 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
11821 COMMISSION OF TEXAS RULE 6.209 INSTALL224 FEET OF 4 INCH POLY MAIN AND RETIRE 224 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
180 COMMISSION OF TEXAS RULE B,209 INSTALL 42 FEETOF3 INCHSTEEL MAIN AND RETIRE42 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
94 COMMISSION OF TEXAS RULE 8.209 REPLACE 58 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
115 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAil-ROAD
9 COMMISSION OFTEXAS RULE 8,209
6 REPLACE 1 SER~CE ~N ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209
wn< Adod!t!Dn~ :Page 16 of:98
llENEFITED
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL~MlX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL- MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All,- MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
A!.1.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
All- MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT JN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201B
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SVSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRrTY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER u 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OIVJSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISIOr./ SYSTEM INTEGRITY MAY-2016'
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIV!SION SYSTEM lNTEGR!TY MAY-2016
LINE ND. PROJECT NUMBER cOST(1)
663 030.25090 40
664 030.25139 10.24a
685 030.25141 307
666 030.25144 (44)
687 030.25154 13
688 030.25155 [70)
689 030.25175 (258)
690 030.25177 12731
691 030.25178 162
692 030.25184 (1391
B93 030.25188 227
694 030.25189 184
695 030.25190 271
696 030.25194 1451
697 030.25197 1551
698 030.25202 (26)
699 030.25203 11
700 030.25211 153)
701 030.25220 161
702 030.25221 138
703 030.26222 154
704 030.25236 63
705 030,25241 [25fi'
706 030.25242 1170)
707 030.2.5245 (36
708 030.25246 [16
709 030.25268 111
710 030.25273 [121
711 030.25274 {24)
712 030.25279 '271
713 030.25288 ram
714 030.25323 1191
715 030.25324 [35)
716 030.25325 8
717 030.25354 11181
718 030.25355 (151
719 030.25359 1441
ATMOS ENERGY CORPORATION, WESTTE<AS DMSION INH:RIM CO.ST R£COVERV ANO RATE ADJUSTMENT ~CPOR.T
ORDJEO REPORT "'I 1-016
ALLOCATED DESC~IPTION 0.F COMll-LETEO PROJECTS DEDICATED TO COST PUBLIC USE IN CALENDAR YEAR 20\6 (2)
INSTALL 32 FEET OF 2 INCH STEEL MAIN AND RETIRE 32 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAil.ROAD
40 COMMISSION OF TEXAS RULE 6.209 INSTALL 17763 FEET OF 2 INCH POLY MAIN, RETIRE 26931 FEET OF STEEL MAIN. AND 396 SERVICES IN ACCORDANCE WITH
10,248 RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL 66 FEET OF 8 INCH STEEL MAIN AND RETIRE66FEETOF 8 INCH STEEL MAIN IN ACCORDANCE WITH RAil.ROAD
307 COMMISSION OF TEXAS RULE 6.209 INSTALL 17 FEET Of 2 INCH POLY MAIN AND RETIRE 17 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(44 COMMISSION OF TEXAS RULE 8.209 INSTALL 16 FEET OF 2 INCH STEEL MAIN, RETIRE 16 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
13 RAil.ROAD COMMISSION OF TEXAS RULE 6.209 INST ALL 26 FEET OF 4 INCH STEEL MAIN. RETIRE 26 FEET OF 4 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH
170 RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
1258) COMMISSION OF TEXAS RUlE 8.209 INSTALL 111 FEET OF 2 INCH AND 85 FEET OF 3 INCH POLY MAIN AND 1 SERVICE AND RETIRE 111 FEET OF 2 INCH AND 85 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
12731 COMMISSION OF TEXAS RULE 8.209 REPLACE 49 FEET OF 2 INCH STEEL MAIN WITH 2 INCH POLY MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD
162 COMMISSION OF TEXAS RULE 8.209 INSTALLS FEET Of 4 INCH POLY MAIN AND RETIRE 8 FEET OF 4 !NCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(139) COMMISSION OF TEXAS RULE 8.209
INSTALL 446 FEET OF 2 INCH POLY MAIN, RETIRE 444 FEET OF 2 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE
227 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL297 FEET OF 2 INCH l'OlYMAIN, RETIRE297 FEET OF 2 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE
164 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 435 FEET Of 2 INCH POLY MAIN. RETIRE 435 FEET Of 2 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE
271 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET OF 2 INCH STEEL MAIN ANO RETIRE 6 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
!45) COMM~SSION OF TEXAS RULE 8.209 REPLACE i SERVICE IN ACCORDANCE WlTH RAllROAD
(55) COMMISSION OF TEXAS RULE 8.209 INSTALL 19 FEET Of 2 INCH STEEL MAIN AND RETIRE 19 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
128\ COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAil.ROAD
11 COMMISSION OFTEXASRULES.209 INSTALL 5 FEET OF 2 INCH STEEL MAIN AND RETIRE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(53) COMMISSION OF TEXAS :RULE 8.209 INSTALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
rs11 COMMISSION OF TEXAS RULE 8.209 INST ALL 225 FEET OF 2 INCH POLY MAIN, RETIRE 225 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
138 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET OF 2 INCH STEEL MAlN AND RETIRES FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WllH RAILROAD
(64] COMMISSION OF TEXAS RULE 8.209 INSTALL 185 FEET OF2 INCH POLY MAIN, RETIRE 185 FEET OF2 INCH STEEL MAIN, AND 5 SERVICES IN ACCORDANCE WITH
83 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL51 FEETOF2 INCH POLY MAIN AND RCTIRE51 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(2551 COMMISSION OF TEXAS RULE 8.209 INSTALl38 FEET OF 4 INCH POLY MAIN AND RETIRE 38 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(170) COMMISSION Of TEXAS RULE 8.209
REPLACE 1 SERVICE AND RETIRE 2 SERVICES IN ACCORDANCE (36) WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 6 FEET OF 2 INOfl POLY MAIN AND RETIRE 6 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAil.ROAD
(16) COMMISSION OF TEXAS RULE 8.209 INSTALL 91 FEET Of 3 INCH POLY MAIN ANO RETIRE 91 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
[11 COMMISSION OF TEXAS RUl-E 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
1121 COMMISS[ON OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
124) COMMISSION Of TEXAS RUl.E 6,209 REPLACE 1 SERVICE IN ACCO:RDANCE Will-I RAfLROAD
(27) COMMISSION Of TEXAS RLilE 8.209 INSTALL 19 FEET OF 6 INCH STEEL MAIN,'INSTALL 36 FEET Of 3 INCH STEEL MAIN, INST ALL 5 FEET OF 2 INCH STEEL MAIN, RETIRE 19 FEET OF 6 INCH STEEL MAIN. RETIR!O 36 FEET OF 3 INCH STEEL MAIN, AND RETIRE 5 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
1891 8.209 REPlACE 1 SERVICE IN ACCORDANCE WrTH RAILROAD
119) COMMISSION Of' TEXAS RULE 8.209 INSTALL 32 FEET OF 2 INCH STEEL MAIN AND RETIRE 32 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
[35) COMMISSION OF TEXAS RULE 6.209 INSTALL 14 FEET OF 2 INCH STEEl MAIN, RETIRE 14 FEET OF2 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH
8 RAILROAD COMMISSION Of TEXAS RULE 6.209
(1181
115
144)
INSTALL84 FEET OF 4 INCH POLY MAIN, RETIRE 84 FEET OF 4 INCH STEEL MAIN ANO 2 SERVICES IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 121 FEET Of 4 INCH l'OLY MAIN, RETIRE 232 FEET OF 4 IMCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 27 FEET Of 3 INCH STEEL MAIN, RETIRE 27 FEET OF 3 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WU( Additions .Pa~e 17 of'9:8
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL· MIX
ALL-MIX
ALL-MiX
ALL-MIX
AlL·MIX
ALL-MIX
ALl·MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVIC!O
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ·2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER • 2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRtlY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRiTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2010
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXASO!Vl:SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY~2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SVSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
o:ao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISIOM SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
LINE NO. PROJECT NUMBER COST[11
720 030.25360 [441
721 030.25361 [21)
722 030.25362 (25)
723 030,25364 (57
724 030.2=6 (15)
725 030.25'367 130
726 030.25377 34
727 030.25393 (38)
728 030.25397 l126l
729 030.25407 5
730 030.25415 [28)
731 030.25416 l1151
732 030.25417 1371
733 0'30.25421 1191
734 030.25422 46
735 030.25428 19
73B 030.25452 [141
737 030.25460 (2BI
736 030.25463 {911
739 030.25485 62
740 030.25486 111)
741 03-0.25499 (174)
742 030.25.502 [44)
743 030.:25504 1421
744 030.25508 3.042
745 030.25510 1971
746 030.25515 (19)
747 030.25517 (50l
748 030.25524 1113)
749 030.25528 24
750 030.25529 101
751 030.25550 1371
752 030.25562 1
753 030.25566 194
754 030.25.569 (53
755 000.25573 186
756 000.25616 (651
757 030.25617 {124l
ATMOS -ENERGY CORPORATION, WEST TEXAS DIVISION INTERIM COST RECOVERY ANO RATE ADJUSTMENT REPORT
PROJECT REPORT CV 2016
ALLOCATED DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS COST PUBLIC USE IN CALENDAR YEAR 2016 [21
INSTALL 276 FEET OF 2 INCH POLY Ml\IN. RETIRE345 FEET OF 2 INCH STEEL MAIN. ANO ASSOCIATED SERVICES IN ACCORDANCE
144 wnH RAILROAD COMMISSION OF TEXAS RULi:. 8.209 INSTALL2539 FEET OF 3J4 INCH POLY MAIN AND RETIRE 2589 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
[21) COMMISSION OF TEXAS RULE 8.209 INSTALL 21 FEET OF 2 INCH STEEL MAIN AND RETIRE 21 FEET OF 2 INCHS STEEL MAIN IN ACCORDANCE WITH Rl\ILROAD
(25 COMMISSION OF TEXAS RULE 8.209
INSTALL9 FEET Of 3 INCH STEEL MAIN, INsTALL 73 FEET OF 2 INCH STEEL MAIN. RETIRE 9 FEET OF 3 INCH STEEL MAIN, AND RETIRE 73 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH
(57l RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 21 FEET DF 2 INCH POLY MAIN AND RETIRE 21 FEET DF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(15) COMMISSION DF TEXAS RULE 8.209 INSTALL 65 FEET OF 2 INCH POLY MAIN AND RETIRE 65 FEET OF STEEL Ml\IN IN ACCORDANCE WITH RAILROAD COMMISSION OF
130) TEXAS RULE 8.209 INST /\LL 40 FEET OF 6 INCH POLY MAIN, RETIRE 40 FEET OF 6 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH
34 RAILROAD COMMISSION OF TEXAS RUl.E 8.209 INSTALL23 FEET OF 2 INCH POLY MAIN AND RETIRE23 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
138) COMMISSION OF TEXAS RULE 8.209 INSTl\l..L 70 FEET OF 2 INCH POLY MAIN AND RETIRE70 FEET OF 2 INCH STEEL MAIN IN ACCOROANCE WITH RAILROAD
(126) COMMISSION OF TEXAS :RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WllH RAILROAD
5 COMMISSION OF TEXAS RULE 6.209 REFLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
[28) COMMISSION OF TEXAS RULE 6.209 INSTALL 153 FEET OF 2 INCH POLY Ml\IN AND RETIRE 153 FEET OF 4 INCH STEEL MAIN IN ACCDR!JANCE WITH RAILROAD
1115) COMMISSION OF TEXAS RULE B.209 INSTALL 70 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES AND RETIRE 70 FEET OF 2 INOH STEEL MAIN AND 2 sERVlCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
137) 8.200
INSTAL!.111 FEET OF 2 INCH POLY MAIN, RETIRE 111 FEET OF 2 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B,209 IN ACCORDANCE
[19) WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 42 FEET OF STEEL MAIN AND 2 SERVICES AND RETIRE 42 FEET OF STEEL MAIN ANO 2 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF
46 TEXAS RULE 6.200 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
19 COMMISSION OF TEXAS RULE 6.209 INSTALL B FEET OF 2 INCH STEEL MAIN ANO RETIRE B FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(14 COMMISSION OF TEXAS RUl.E 8.209 REPlACE 1 SERVICE IN ACCORDANCE WITH RAtLROAD
126 COMMISSION OF TEXAS RULE 8.209 INST /\LL 17 FEET OF 6 INCH POLY MAIN ANO RETIRE 17 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH Rl\ILROAD
(911 COMMISSION OF TEXAS RULE 6.209 INSTALL 11 FEETOF6 INCHSTEELMAIN AND RETIRE 11 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
62 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
(11) COMMISSION OF TEXAS RULE 8.209 INSTALL 422 FEET OF 2 INCH POLY MAIN AND RETIRE 422 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(174) COMMISSION Of TEXAS RULE 8.200 REPLACE 2 SERVICES IN ACCORDANCE WITfl RAILROAO
(44) COMMISSION OF TEXAS RULE a.200 lNSTALL 19 FEET OF 3 INCH POLY MAIN AND RETIRE 19 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
1421 COMMISSlON DF TEXAS RULE B.209 INSTALL 13773 FEET OF2 INCH POLY MAIN, RETIRE 13773 FEET OF 2 INCH STEEL Ml\IN AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
3,042 8.209 INSTALL 20 FEET OF 2 INCH STEEL Ml\IN AND RETIRE ZO FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
197l COMMISSION OF T!OXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WJTH RAILROAD
09) COMMISSION OF TEXAS RULE 8.209 INSTALL 307 FEET OF 4 INCH POLY Ml\IN AND RETIRE 307 FEET OF" INCH STEEL MAIN IN AccoRDANCE WITH RAILROAD
(50l COMMISSION OF TEXAS RULE 8.209 INSTl\LL21 FEET OF 4 INCH sTEELMAIN AND RETIRE21 FEET Of 4 INCH STEEL M/\IN IN ACCORDANCE WITH RAILROAD
(1131 COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH R/\ILROAO
24 COMMISSION OF TEXAS RULE 6.209
INSTALL 160 FEET OF 2 INCH POLY MAIN, RETIRE 160 FEET OF 2 INCH STEEL MAIN, ANO ASSOCIATED SERVICES IN ACCOR.DANCE
101 WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
(37) COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
7 COMMISSION OF TEXAS RULE 6.200
(94)
[531
'661
[65)
11241
REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH Rl\ILROAD COMMJSSION OF TEXAS RULE 8.209 INSTALL 25 FEET OF 4 INCH POLY MAIN AND RETIRE 25 FE.ET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST AU. 21 FEET OF 4 INCH STEEL MAIN AND RETIRE 21 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 39 FEET OF 4 INCH STEEL MAIN. RETIRE 39 FEET OF 4 INCH STEEL M/\IN, AND 2 SERVlCES IN ACCOROANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
WTX Additions Page 18 of98
BENEFITED
/\LL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MlX
ALL-MIX
ALL-MIX
ALL-MIX
/\LL-MIX
ALL-MIX
/\LL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
1\1..L-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
/\LL-MIX
/\LL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL- MlX
ALL-MIX
ALL· MIX
ALL-MIX
/\LL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
PATE PL.ACED IN GAS Pl.ANTIN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-Z016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-Z016
030 TEXAS OIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SVSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY ·2016
030 TEXAS DIVISION SVSTEM INTEGRITY MAY-2016
030 TEXAS OIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITI' MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201S
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
UNE NO. PROJECT NUMBER COST!1)
758 030.25618 (211
759 030.25665 (691
760 030.20666 11271
761 030.25667 (60)
762 030.25668 122)
763 030.25571 123l
764 030.25677 62
765 030.25684 (2481
756 030.25669 !46)
767 030.25690 (33)
766 030.25691 (29)
769 030.25592 (65)
770 030.25693 [93)
771 030.251594 11351
772 030.25696 (11.9]
773 030.25714 30
774 030.25728 1261
775 030.25729 (321
776 030.25730 (301
777 030,25740 515
778 030.25741 460
779 030.25742 352
700 030.25764 184)
781 030,25766 '70
782 030.25769 124)
783 030.25770 (33)
784 030.25771 156
785 030.25772 (97
786 030.25777 615
787 030.25776 219
788 030.25779 a
769 030.25780 1291
790 030.25787 (371
791 030.25788 1,113
792 030.25601 151
793 030.25805 1741
794 030.25606 [61
ALLOCATED COST
(21)
!69)
(127)
(60)
[22)
[23)
52
1246
146)
(33)
(291
165'
(93
(1351
111•
30
l28l
(32)
(30)
515
460
352
[64)
(701
1241
1331
(56)
[971
615
219
ATMOS ENEHGY CORPOMTION, WESTTEXAS DIVISION INTERIM COST RECOVERY ANO RA.TEAOJUSTMJ;NT flEPORT
PROJECT .R!EPORICV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR '"115 !2) BENEFITED
INSTALL 7 FEET OF 2 INCH STEEL MAIN AND RETIRE 7 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 11 FEET Of 4 INCH STEEL MAJN AND RETIRE 11 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS ;RULE 8.209 ALL-MIX INSTALL 78 FEET OF 3 INCH POLY MAIN ANDRETIRE7l3 FEET OF4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL- MIX INSTALL 10 FEET OF 5 INCH STEEL MAIN AND RETIRE 10 FEET OF 6 INCH STEEL MAJN IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITf-i RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX REPLACE t SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL 210 FEET OF 2 INCH STEEL MAIN. RETIRE 210 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 246 FEET OF 4 INCH POLY MAIN, RETIRE 246 FEET OF 6 INCH STEEL MAJN, AND 1 SERVICE IN ACCORDANCE WIT!l RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 21 FEET OF 2 INCH STEEL MAIN, RETIRE 21 FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 AL!.-MIX INSTALL 28 FEET OF 4 INCH STEEL MAIN, RETIRE 28 FEET OF 4 INCH STEEL MAIN, AND 1 SER~CE IN ACCORDANCE WITI-l RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 51 FEET OF 3 INCH POLY MAIN, RETIRE 51 FEET OF 3 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 All.- MIX INSTALL 110 FEET OF 3 INCH POLY MAIN AND RETIRE 114 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 158 FEET OF 4 INCH POLY MAIN AND RETIRE 108 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
INSTALL 500 FEET OF 2 INCH POLY MAJN, RETIRE 500 FEET OF 2 INCH STEEL MAJN AND ASSOCIATED SERVICES IN ACCORDANCE WtTH RAILROAD COMMISSION OF TEXAS RULE 8.'"19 ALL-MIX INSTALL 12 FEET OF 2 INCH POLY MAIN A~D RETIRE 12 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX
INSTALL686 FEETOF2 INCH POLY MAIN, RETIRE688FEETOF2 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE 6.209 Ail-MIX INSTALL262FEETOF 4 INCHPOLY MAIN, INSTALL289 FEET OF 2 INCH POLY MAIN, RETIRE 262 FEET OF 4 INCH STEEL MAIN, RETIRE 289 FEET OF 2 INCH STEEL MAJN, ANO ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE :B.2.09 ALL-MIX
INSTALL 392FEET OF2 INCH POLY MAIN, RETIRE 392 FEET OF2 INCH STEEL MAlN AND ASSOCIATED SERVICES IN ACCORDANCE WJTI-l RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
INSTALL 16 FEET OF 2 INCH STEEL MAIN, RETIRE 16 FEET OF 2 INCH STEEL MAJN AND 1 RESIDENTIAL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 46 FEET OF 4 INCH POLY MAIN ANO RETIRE 46 FEET OF 4 iNCH STEEL MAlN IN ACCORDANCE WITH RAJLROAO COMMISSION OF TEXAS RULE B.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX REPLACE 2 SERVICES IN ACCORDANCE WITH RAIL!lOAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL25 FEET OF 4 INCH POLY MAJN, RETIRE25 FEET OF 4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITI-1 RAILROAD COMMISSION Of TEXAS RULE B.209 ALL-MIX INSTALL31 FEETOF4 INCH PDLYMAIN, RETIRE31 FEET OF 4 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WlTH RAJLROAD COMM1SSION OF TEXAS RULE 6.209 ALL-MIX
INSTALL 8 FEET OF 2 INCH AND 525 FEET Of 4 INCH POLY MAIN ANO 11 SERVICES AND RETIRE B FEET OF 2 INCH AND 525 FEET OF 3 INCH STEEL MAJN AND 11 SERVl<lES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL 90 FEET Of 2 INCH POLY MAIN, RETIRE 90 FEET OF 2 INCH STEEL MAIN. AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 11S FEET OF 2 INCH POLY MAIN. RETIRE 116 FEET OF 2 INCH STEEL MAIN, AND 4 SERVICES IN ACCORDANCE WITH
3 RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 49 FEET OF 2 INCH POLY MAIN, RETIRE 49 FEET Of 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
(29) RAILROAD COMMISSION OF TEXAS RULE 8_209 INSTALL 21 FEET OF 3 INCH POLY MAIN AND RETIRE 1163 FEET OF 3 lNCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
1371 COMMISS!ONOFTEXAS RULE 8.209 INSTALL3745 FEET OF 21NCH POLY MAIN, RETIRE 4948 FEET OF 4 INCH, 3 INCH, 2 INCH AND 1.25 INCH STEEL MAIN, AND a SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF
1,113 TEXAS RULE 8.209 INSTALL 260 FEET OF 2 INCH POLY MAIN AND RETIRE 280 FEET OF 2 INCH STE;EL MAIN IN ACCORDANCE WITH RAILROAD
151 COMMISSION OF TEXAS RULE 8.209 REPLACE 2 SERVICES IN ACCORDANCE WITH RAilROAD
174) COMMISSION OF TEXAS RULE 8.209 INSTALL ao FEET 01' 2 INCH POL y MAIN AND RETIRE BO FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITl-I RAILROAD
(6) COMMISSION OF TEXAS RULE 8.209
WIX Additions. Page 19 of 98
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MlX
DA.TE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OMS ION SYSTEM l~'TEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 T!:XAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
LINE NO. PROJECT NUMBER COST(1)
795 030.25822 (81}
796 030.25'335 (27)
797 030.25B36 (31)
798 030.25840 9
799 030.2oB41 14
BOO 030.25843 {40)
801 030.25844 54
802 030.25860 196)
803 030.25001 (39)
604 0'30,25864 15
605 030.25'365 99
806 030.2586"6 100
807 030.25670 18
808 030.25873 28
909 030.25875 100)
810 030.25877 <1141
811 030.25881 {B71
812 030.25882 160\
813 030.25884 1231
614 030.25904 41
815 030.25908 62
816 030.25909 92
817 030.25913 90
B1B 030.26914 34
am 030.25928 3
820 030.2:5935 21
821 030.25936 439
822 030.25955 107
823 030.25992 59
624 030.26007 7
B25 o:m.26010 11B1
626 030.26011 16)
827 030.26013 110I
828 030.28014 1231
829 030.26019 41
830 030.26021 66
831 030.26022 1101
632 030.26033 {411
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISlON INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CT 2016
ALLOCATED DESCRIPTION Of COMPLETED PROJECTS DEDICATED TO CUSTOMERS cosr PUBLIC USE IN CALENDAR YEAR 2016 (2] BENEFITED
lNST ALL 22 FEET OF 3 lNC!1 STl'E\_ MAIN AND RETIRE 22 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(81) COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAlLROAD
(27) COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCOR.DANCE WITH RAILROAD
(311 COMMISSION OF TEXAS RllLE 8.209 AlL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
9 COMMISSION OF TEXAS RULE 8.209 ALL- MIX INSTALL 20 FEET OF 4 INCH STEEL MAIN AND RETIRE 20 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
14 COMMISSION OF TEXAS RlJLE 8.209 ALL-MIX INST ALL 11 FEET Of 2 INCH STEEL MAIN AND RETIRE 11 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
140) OOMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 21 FEET OF 6 INCH POLY MAIN AND RETIRE 21 FEET OF 6 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD
54 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 33 FEET OF 6 INCH POLY MAIN, RETIRE33 FEETOFS INCH STEEL MAIN, AND 2 SERVICCS IN ACCORDANCE WITH
(96) RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 30 FEET OF 4 INCH POLY MAIN, RETIRE30FEETOF4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
{39) RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL42 FEET OF 2 INCH STEEL MAIN, RETIRE42 FEET OF2 INCH STl'EL MAIN. AND 2 SERVICES IN ACCORDANCE WITH
15 RAILROAD COMMISSION OF TEXAS RULE B.209 All-MIX INSTALL 60 FEET OF 3 INCH POLY MAIN, RETIRE SO FEET OF3 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
99 RAILROAD COMMlSSION OF TEXAS RULE 9.209 All-MIX
INSTALL 290 FEET OF >INCH POLY MAIN, RETIRE 290 FEET OF 2 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE
100 WlTH RAILROAD COMMISSION OFTEXAS RULE 8.209 All· MIX INSTALi- 40 FEET OF 2 INCH POLY MAIN AND RETIRE 40 FEET OF 2 INCH STOEL MAIN IN ACCORDANCE WITH RAILROAD
1B COMMISSION OF Tl'XAs RULE 6.209 AlL-MIX INST All 162 FEET OF 2 INCH POLY MAIN AND RETIRE 162 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAlLROAD
28 COMMISSION Of TEX/IS RULE 8.209 ALL-MIX INSTALL 7 FEET OF 2 INCH POLY MAIN AND RETIRE 7 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(861 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 25 FEET OF 3 INCH POLY MAIN AND RETIRE 25 FEET OF 3 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD
(114) COMMISSION OFTEX'.AS RUlE 8.209 ALL-MIX INSTALL 15FEETOF3 INCH POLY MAIN AND RETIRE 15FEETOF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAll.ROAD
(871 COMMISSION OF TEXAS RLJLE 6.209 ALL-MIX INSTALL 20 FEET OF 4 INCH POLY MAIN AND RETIRE 20 FEET OF B INCH STl'EL MAIN IN ACCORDANCE WITH RAllROAD
(60) COMMISSION Of TEXAS RLJLE B,209 ALL- MIX INSTALL 22 FEET OF 2 INCH POLY MA1N AND RETIRE 22 FEET OF 1.25 INCH STEEL MAIN IN ACCCORDANCE wrn; RAILROAD
123\ COMMISSION OF TEXAS RULE 8.209 ALL- MIX INSTA!-L 19 FEETOF4 NCH POLY MAIN AND RETIRE 19 FEETOF6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
41 COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 SERVICE IN ACCORDANCE WITH RAlLROAD
62 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 117 FEET OF 2 INCH POLY MAIN /\ND RETIRE 117 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WllH RAILROAD
92 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL96 FEET OF 2 INCH POLY MAIN AND RETIRE 96 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAlLROAD
90 COMMISSION OF TEXAS RULE 8.209 A!-L-MIX INSTA!-L 110FEET OF2 INCHPOLY MAIN AND RETIRE 110 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
34 COMMISSION OF TEXAS RULE 8.209 All-MIX INSTALL 144 FEET OF2 INCH POLY MAlNAND RETIRE209 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
3 COMMlSSION OF TEXAS RULE B.209 ALL-MIX RETIRE 50 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH
21 RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 290 FEET OF2 INCH POLY MAIN, RETIRE 290 FEET Of 2 INCH AND 3 INCH STEEL MAIN. AND 2 RESIDIENT1A!- SERVICES IN ACCORDANCE WllH RAlLROAD COMMISSION OF TEXAS RULE
439 6.209 ALL-MIX
INSTALL 216 FEET OF 2 INCH POLY MAIN, RETIRE 216 FEET Of 2 INCH STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE
107 WITH RAILROAD COMMISSION Of TEXAS RLJLE 8,209 /Ill-MIX INSTALL 60 FEET OF 2 INCH POLY MAIN AND RETIRE 58 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
69 COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLJLE 6.209 IN ACCORDANCE WITli
7 RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL 35 FEET Of 4 INCH POLY MAIN, RETIRE 35 FEET OF 4 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH
1181 RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 11 FEET OF 4 INCH STEEL MAIN AND RETIRE 11 FEET OF 4 INCH STEEL MAIN IN AOCORDANOE WITH RAILROAD
161 COMMISSION OF TEXAS RULE 6.209 ALL-MIX INST ALL 24 FEET OF 4 INCH POLY MAlN AND RETIRE 24 FEET OF 4 INCH STEEL MAlN IN ACCORDANCE WITH RAlLROAD
<101 COMMISSION OF TEXAS RULE B.209 ALL- MIX INSTALL 24FEET OF2 INCHPOLY MAIN, RETIRE 24 FEET OF 2 INCH STEEL MAIN. AND 2 SERVICES IN ACCORDANCE WllH
(23) RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 166 FEET OF 2 INCH POLY MAIN AND RETIRE 166 FEET Of 2 INCH STEEL MAIN IN ACCORDANOE WITH RAILROAD
47 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL45FEET OF4 INCH POLY MAIN, RETIRE 45 FEET OF 4 INCH STEEL MAIN. AND 2 SERVICES IN ACCORDANCE WITH
66 RAlLROAD COMMISSION OF TEXAS RllLE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAlLRO/\D
110 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL234 FEET OF 4 INCH POLY MAIN AND RETIRE234 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WllH RAILROAD
(41 COMMISSION OF TEXAS RULE 8.209 All-MIX
WTXAddi•foti5: Piilge 20of98
DATE PLACcD IN
GASPLANTIN LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 Tl'XAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 Tl'XAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
I
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DJVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-20115
03-0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTl'GRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·201B
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTl'M INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTl'M INTEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM INTl'GRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SY9TEM INTEGRrTY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRllY M/\Y-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2010
mm TEXAS DIVISION SYSTEM INTl'GRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO, PROJECT NUMBER COST(1l COST
833 030.26034 412 412
834 030,2.6035 19 19
835 030.:16048 [31) 131
B36 o:m.26049 16 16
837 030.2£050 (221 (22)
838 030.26059 45 45
839 030.26060 83 83
840 030.26070 90 90
841 030,26097 549 54•
842 030.26136 199 199
843 030.:16142 89 89
644 030.26145 23 23
845 030,26162 12 12
846 030.26164 32 32
647 030.261"72 26 26
B48 030.215203 189 189
849 000.26215 54 54
850 030.26237 22 22
851 030,2.6246 170 170
852 030.26247 41 41
853 030.26251 To 75
854 030,:16263 1B 13
855 030.:16269 18 18
856 030_26270 35 35
857 030.26308 50 50
858 030.26317 1,043 1,043
859 030.26.119 so so
860 030.26320 1 1
861 0;3;0.26:327 oS2 582
002 030.26331 62 62
003 030.:26332 39 39
864 030.26333 39 39
665 030.26344 123 123
666 030.26365 82 82
867 030.26361! 34 34
ATMOS ENERGY CORPORATION, WiEST TEXAS DIVISION INTERIM COST RECOVERY AND RAH Al>IUSTMENT REPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (21
INSTALL 305 FEET OF 4 INCH POLY MAIN AND RETIRE 305 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 74 FEET OF 2 INCH POLY MAIN ANO RETIRE 74 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 36 FEET OF 2 INCH STEEL MAIN, RETIRE 36 FEET OF 2 INCH STEEL MAJN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL60FEET OF2 INCH POLY MAIN, RETIRE 60 FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL 101 FEET OF 3 INCH POLY MAIN, RETIRE 101 FEET OF 3 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 181 FEETOF21NCH PPLYMAIN, RETIRE 181 FEETOF2 INCH STEEL MA(N, AND ASSOC!ATEO SERVICES IN ACCORDANCE WITH RAILROAD COMMJSSION OF TEXAS RULE 8.209 INSTALL 103 FEET OF 4 INCH POLY MAIN AND RETIRE 103 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL2B60 FEET OF 4 INCH PO!.Y MAIN, RETIRE 2860 FEET OF 4 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 226 FEET OF 2 INCH POLY MAIN AND RETIRE 226 FE!;T OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAJLROAD COMMISSION Of TEXAS RULE 8,209 INSTALL 87 FEET OF 4 INCH POLY MAIN AND RETIRE 87 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAJLRDAD COMMISSION OF TEXAS RULE 8.209 INSTALL 75 FEET OF 3 INCH POLY MAIN AND RETIRE75 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF 1i:;XA:S .RULE 5.20!9 INSTALL40 FEET OF 2 INCH POl.Y MAIN ANDRETIRE40 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 130FEET DF2 INCH POLY MAJNAND RETIRE 130 FEET Of 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 10 FEET OF 2 INCH POL V MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAJN IN ACCORDANCE WITH RAJLRDAD COMMISSION OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.20ll INST ALL 52 FEET OF 4 INCH POLY MAJN, RETIRE 52 FEET OF 4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 163 FEET Of 2 INCH POLY MAIN AND RETIRE 153 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL 115 FEET OF 21NCH POLY MAIN. AND RETIRE 115 FEET Of 2 INCfl STEEL MAJN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 INSTALL 52 FEET OF 4 INCH POLY MAIN, RETIRE 52 FEET OF 4 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WJTH RAJLRDAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 7 FEET OF 3 INCH STEEL MAIN ANPRETIRE7 fEETOF 3 INCH STEEL MAIN IN ACCORDANCE WITH RA!LROAD COMMISSION OF TEXAS RULE 6_209 INSTALL 13 FEETOF2 INCH PPLYMAIN, RETIRE 13 FEET DF2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RA!LROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 140 FEET OF 2 INCH POLY MAIN, RETIRE 140 FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WJTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL30B3 FEET Of 2 INCH PoLY MAIN. RETIRE 3083FEETOF 3 INCH AND 2 INCH STEU MAIN, AND ASSOCIATED SERVlCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 18 FEET OF 2 INCH STEEL MAIN AND RETIRE 18 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAJLROAD COMMISSION Of TEXAS RULE 8.209 INSTALL5 FEET OF 4 INCH STEEL MAIN AND RETIRE 5FEET PF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL343 FEET OF 4 INCH POLY MAIN, RETIRE353 FEETOF8 INCH AND 6 INOH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 189 FEET OF 2 INCH PPLYMAIN, INSTALL63 FEET OF 1.25 INCH POLY MAIN, RETIRE 252 FEET OF 2 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE Will-I RAtLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 108 FEET OF 4 INCH POLY MAIN, RETIRE 106FEETOF3 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE 6.209
INSTAU..210 FEET OF 2 INCHPOLV MAIN, RETIRE210FEET Of 2 INCH STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,20ll INSTALL 109 FEET OF 4 INCH POLY MAIN ANO RETIRE 109 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL26 FEET OF4 INCH POLY MAIN, INSTALL 33 FEET OF 3 INCH POLY MAJN, RETIRE5B FEET OF 4 INOH STEEL MAIN, AND RETIRE 3 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WffH RAILROAD COMMISSION OF TEXAS RULE B.209 INST ALL 44 FEET OF 4 INCH POLY MAIN AND RETIRE 44 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209
WD< Additions Pvgl!!:ll of98
CUSTOMERS BENEFITED
ALL-MIX
All-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
llLL·MIX
ALL-MIX
Al.l.-MIX
All-MIX
ALL.MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
DATE Pl.ACED'" GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INH;GRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIV!SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2.018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lr-ffEGRITY MAY-2016
030 TEXAS DIVlSIDN SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM lNTEGR!IT MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201"
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST(11
868 030.26367 62
869 030.26368 16
870 030.26369 34
671 030.26376 m 672 030.26387 [13)
873 030.26388 39
074 030.26392 66
075 030.26395 13
876 030.26396 74
877 030.26421 12
878 030.26423 16
679 030.26424 36
600 030.26425 11
881 030.26448 63
882 030.26453 36
883 030.26454 137
884 030.26466 19
885 000.26467 18
886 030.26470 42
887 030.26471 198
880 030.26473 107
889 030.264B4 27
890 030.2.6496 52
891 o:m.2a507 [50)
892 030.26508 17:2
093 030.26647 49
094 030.26540 49
095 C30.2B:569 22
096 030.26577 263
BS7 000.26560 45
898 030.2B5S1 7.198
899 030.26582 46
900 030.26599 14
901 030.26£17 7
902 030.26624 16
903 030.26625 35
904 030.26626 13
905 030.26627 30
ALLOCATED COST
62
16
34
121
(131
39
66
13
74
12
16
36
11
63
36
137
19
18
42
196
187
27
52
150\
1n
49
49
22
263
45
7.196
46
14
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION INTERfM COST RECOVflW ANO RATE ADJUSTMENT REPORT
PROJECT REPORT C.V 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 {21 BENEFITED
INSTALL 251 FEET OF 2 INCH POLY MAIN, RETIRE 251 FEET OF 2 INCH STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 44 FEET OF 4 INCH POLY MAIN ANO RETIRE 44 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WffH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INST ALL 75 FEET OF 2 INCH POLY MAIN AND RETIRE 75fEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 11.5 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAs RULE 8.209 ALL-MIX INSTALL 17 FEET OF 3 INCH POLY MAIN AND RETIRE 17 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE W!TH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX lNSTALL 23 FEET OF 6 INCH POLY MAIN AND RETIRE 23 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 10 FEET OF 3 INCH STEEL MAJN AND RETIRE 10 FEET OF 3 INCH STEEL MA!N IN ACCORDANCE WtTH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All· MIX INST ALL 76 FEET OF 2 INCH POLY MAIN, RETIRE 76 FEET CF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE; 6,209 ALL-MIX RETIRE 2 1 INCH SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 64 FEET OF 2 INCH POLY MAIN AND 64 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 263 FEET OF 2 INCH POLY MAlN AND 4 SERVICES AND RETIRE 161 FEET Of 2 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE W;TH RAILROAD COMMISSION OF TEXAS RLILE 8.209 ALL-MIX INSTALL 16FEETOF2 INCH POLY MAIN AND RETIRE 18FEETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6,209 ALL-MIX INSTALL 18 FEET OF 2 INCH POLY MAIN AND RETIRE 18 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 ALL-MIX INSTALL47 FEET OF 4 INCH POLY MAJN AND RETIRE 47 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 All-MIX INST All. 240 FEET OF 2 INCH POLY MAIN AND 8 SERVICES ANO RETIRE 240 FEET OF 2 INCH STEEL MAIN AND 6 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All.·MIX INSTALL 167SFEET OF 1.25 POLY MAIN AND RETIRE 1679 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 ALL-MIX INSTALL 17 FEET OF 2 INCH POLY MAIN AND RETIRE 17 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITI-i RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 ALL-MIX INSTALL 182 FEET OF 4 INCH POLY MAIN. RETIRE 175 FEET OF 6 INCH STEEL MAIN, RETIRE 7 FEET OF 4 INCH STEEL MAJN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 129 FEET OF 2 INCH POLY MAIN, RETIRE 129 FEET OF 2 INCfl STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX INST ALL 33 FEET OF 2 INCH POLY MAIN ANO RETIRE 33 FEET OF 2 INCH STEEL MAJN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 10FEETOF2 INCH POLY MAIN AND 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL429 FEET OF 2 INCH POLY MAIN, RETIRE366 FEET OF 2 INCH STEEL MAIN, RETIRE 63 FEET OF 1.5 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 104 FEET OF 2 INCH POLY MAIN ANO 104 FEET OF 2 INCH STEEL MAJN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All.-MIX INSTALL 13010fEET OF2 INCH POLY MAIN, RETIRE 18461 FEET OF STEEL MAIN, AND 212 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX lNSTALL 60 FEET OF 4 INCH POLY MAIN AND RETIRE 60 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8,209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION DF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
7 COMMISSION OF T<XAS RULE 8.209 ALL-MIX RETIRE 30 FEET OF 2 INCH STEEL MAIN ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
16 8.209 AU.-MIX INSTALL 146 FEET OF 2 INCH POLY MAIN, RETIRE 146 FEET OF 2 INCH STEEL MA!N, AND 3 SERVICES IN ACCORDANCE WITH
35 .RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
13 COMMISSION OF TEXAS RULE 8.209 ALL-MIX
INSTALL42 FEET OF2 INCH STEEL MAIN AND2SERVICIOS AND 42 FEET OF 2 INCH POLY MAIN AND 2 SERVICES IN ACCORDANCE
30 WITH RAILROAD COMMISStON OF TEXAS RULE 6.209 ALl.-MIX
WTX Additio1ts: Page22 of98
D.A.1 c: f"l.ACE.D IN
GAS PLANT IN LOCATION PURPOSE Of PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRffY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2018
030 TEXAS OIVJSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM lNTEGRffY MAY-2016
030 TEX.AS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITI' MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D1VISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE No. PROJECT NUMBER COST(1)
906 030.26628 51
907 030.26629 16
BOO 030.26639 9
909 030.26640 16
910 030.26666 72
911 030.26668 39
912 030.26680 15
913 030,26681 9
914 030.28683 20
915 030.2666G 28
916 030,26698 17
917 030.26700 536
918 030.26705 9
919 030.26706 99
920 030.26707 329
921 030.26716 26
922 0'30.26722 56
923 030.26730 48
924 030.26732 43
926 030.2.6734 31
926 030.2.6751 14
927 030.26755 90
928 o:m.2a757 61
929 030.26759 22
930 030.28767 26
931 030.28775 19
932 030.26821 335
933 030.26624 46
9"4 030.28854 122
935 030.26860 29
936 030.26868 618
937 000.26870 32
936 030.26871 42
939 OJ0.26674 85
940 030.26905 199
941 030.26900 131
942 030.26909 125
ALLOCATED COST
51
16
9
16
72
39
16
A1MO.S ENERGY CORPORATION, WE:STTEXAS DJVISION INTERIM COST RECOVERY AND RATE AOJU:STMENT REPORT
PROJECT REPOFl:T C'f l016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 (21 BENEFITED
INSTALL 113 FEET OF 4 INCH POLY MAIN, RETIRE 113 FEET OF 3 INCH STEEL MAIN, AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 41 FEET OF 2 INCH STEEL MAIN AND RETIRE 41 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITI-1 RAILROAD COMMISSlON OF TEXAS RULE 8.209 ALL-MIX INSTALL 16 FEET OF2 INCH POLY MAIN AND RETIRE 18 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITK RAllROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL 62 FEET OF 2 INCH POLY MAIN AND RETIRE 52 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.<ro9 ALL-MIX INSTALL 190 FEET OF 4 INCH POLY MAIN AN!l RETIRE 90 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAO COMMISSION OF TEXAS RULE 8,209 ALL-MIX INSTALL 118 FEETOF2 INCHPOLY MAINAN!lRETIRE 118FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX INSTALL 21 FEET OF >INCH POLY MAIN AND RETIRE 21 FEET OF STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.2.09 ALL-MIX INSTALL21 FEET OF 1.26 INCH POLY MAINANDRETIRE21 FEET Of 1 INCH STEEL MAIN IN ACCORDANCE WITH RAIUROAD
9 COMMISSION OF TEXAS RLJLE 8.209 ALL-MIX
20
28
17
536
9
99
32'l
2B
56
48
43
31
14
90
61
22
25
19
336
46
122
29
616
32
42
85
199
131
126
INST ALL 18 FEET OF 3 JNCH STEEL MAIN AND RETIRE 1 B FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITfl RAIUROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 38 FEET OF 2 INCH POLY MAIN. RETIRE 38 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2Q9 INSTAl.l361 FEET OF 4 INCH POLY MAJNAND RETIRE351 FE!'T Of 6 INCK STEEL MAIN IN ACCORDANCE WITH RAIUROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE wm1 RAILRDAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE B.209 INSTALL 1300 FEETOF3 INCH POLY MAIN AND RETIRE 1300FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 85 FEET OF 2 INCH POLY MAIN AND RETIRE 85 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 35 FEET OF 2 INCH POLY MAIN, RETIRE35FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITK RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 29 FEET OF 4 INCH POLY MAIN AND RETIRE 29 FEE.TOF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAIUROAD COMMlSSlON OF TEXAS RULE B.209 INSTALL 15 FEET OF 4 INCH STEEL MAIN, RETlRE 15 FEET OF 4 INCH STEEL MAIN, AND 2 SERV!CES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 109 FEET OF 4 JNCH POLY MAIN AND RETIRE 109 FEET OF J INCH STEEL MAJN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 218 FEET OF 2 INCH POLY MAIN AND RETIRE 216 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITK RAILROAD COMMISSION OF TEXAS RULE 6.209
INSTALL237 FEET OF 2 INCH POLY MAJN. RETIRE 237 FEET OF 2 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE WITI-1 RAIUROAD COMMISSION OF TEXAS RULE 8,209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAIUROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET OF 2 INCH POLY MAIN, RETIRE 6 FEET OF 2 INCH PVC MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAIUROAD COMMISSION OF TEXAS RULE 6.2og INSTALL 505 FEET OF 6 INCH POLY MAIN ANO RHIRE 606 FEET OF S INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.20B INSTALL 125 FEET OF 2 INCH POLY MAIN AND RETIRE 125 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 45 FEET OF 3 INCH STEEL MAIN AND 1 SERVICE AND RETIRE 45 FEET OF 3 INCH STEEL MAJN AND 1 SERVICE IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 70FEET OF2 INCH POLY MAIN. RETIRE 70 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD C9MMISSION Of TEXAS RULE S.209 INSTALL 551 FEET OF 4 INCH POLY MAIN AND RETIRE 547 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL4BfEET OF0.75 INCH POLY MAIN AND RETIRE4S FEET OF 2 INCH ST!OEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S.209 INSTALL 6 FEET OF 4 INCH STEEL MAIN AN!l RETIRE 6 FEET OF 4 INCH STEEL MAIN iN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL39 FEET OF6 INCH POLY MAIN, RETIRE 39 FEET OF 6 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209
JNSTALL6S FEET OF4 INCH STEEL MAJN, INSTALL2B FEET OF 2 INCH STEEL MAIN, RETIRE 58 FEET OF 4 INCH STEEL MAIN, AND RETIRE 28 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 63 FEET OF 2 INCH POLY MAIN, RETIRE 63 f~f:;T OF 2 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 14 FEET OF B INCH STEEL MAIN, RETIRE 1270 FEET OF 6 INCH STEEL MAIN, AND RETIRE 325 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE 8.209
WT:XAdditions Page 23 of98
Al.L-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALI.-MIX
ALI.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
Al.L-MIX
All-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS OIVISIOI< SYSTEM INTEGRITY MAY-2016 "
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 T!'XAS !llVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-<ro16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201S
000 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVlslON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY w2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYS1EM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRJTY MAY-2016
030 TEXAS DIVISION SYSTEM !NTEGRITY MAY-2016
030 TEXAS DIVISION SVSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-<ID16
030 TEXAS !llVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COSTj1)
943 OJ0.28917 673
944 030.26925 116
945 030.26900 47
946 030.26976 402
947 030.26983 39
94a 030,26988 13
949 030.26989 93
950 030.269'95 32
951 030.27000 50
952 o:ao.27001 16
953 030.27013 80
954 030.27014 21
955 030.27016 17
956 030.27020 92
957 030.27023 293
958 030.27024 267
959 030.27037 60
960 030.27043 128
961 030.27054 170
962 030.27055 343
963 030.27057 20
964 030.27056 9
965 030.27060 6
966 000.27001 27
967 030.27062 42
968 030,27064 44
969 030.27077 92
970 030.27095 37
971 030.27099 108
972 030.27100 186
973 030.27101 244
974 030.27107 3
975 030.2712:1 117
976 030.27123 31
977 030.27124 14
978 030.27126 116
979 030,27127 211
980 030.27137 21
ATMOS ENEFl6V CORPORATION, WEST TEXAS OIVISION INTERIM COST RECOVERY AND RATE ADJUSTMENT R.!;flOlll'
PROJECT Fl.EPoRT CY 201ti
ALLOCATED DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS COST PUBLIC USE IN CALENDAR YEAR 2016 {2)
INSTALL-487 FEET OF 4 INCHPOLY MAIN, RETiRE471 FEETOF3 INCH STEEL MAIN, AND 3 sERVICES IN ACCORDANCE WITH
573 RAJLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 138 FEET DF2 INCKPDLY MAIN, RETIRE 13BFEETOF2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITK
116 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL39 FEET OF 4 INCH POLY MAIN, RETIRE 39 FEET OF 4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITfl
47 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTAU. 533 FEET Of 2 INCK POLY MAIN. RETIRE 533FEET OF3 INCH STEEL MAIN, AND 5 SERVICES IN ACCORDANCE WITH
402 RAil.ROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 22 FEET OF 2. INCH STEEL MAIN AND RETIRE 22 FEET Of 2 INCH STEEi. MAIN IN ACCORDANCE WITH RAILROAD
39 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
13 COMMISSION OF TEXAS RULE 8.209 INST ALL25 FEET OF PD!. Y MAIN AND RETIRE 25 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITK RAILROAD COMMISSION OF
93 TEXAS RULE 8.209 INSTALL 14 FEET OF 4 INCH STEEL MAtN AND RETIRE 14 FEET Of 4 tNCK STEEL MAIN IN ACCORDANCE WITH RAILROAD
32 COMMISSION OF TEXAS RULE 8.209
INST ALL 2e FEET OF 2 JNCH POLY MAIN, RETIRE 28 FEET OF 2 INCH STEEL MAlN, AND 1 RESIOENTIAL SERVICE IN ACCORDANCE
50 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
16 COMMISSION OF TEXAS RULE B.209 INSTALL 12 FEET OF 2 INCH STEEL MAIN AN!l RETIRE 12 FEET OF 2 INCH STEEL MAJN IN ACCORDANCE WITH RAILROAD
BO COMMISSION OF TEXAS RULE B,209 REPLACE 1 SERVICE IN ACCORDANCE wrrH RAILROAD
21 COMMISSION OF TEXAS RULE B.209 INSTALL 7 FEET OF 2 INCH POLY MAIN AND RETIRE 7 FEET OF 2 INCH $TEEL MAIN IN ACCORDANCE WITH RAILROAD
17 COMMISSION OF TEXAS RULE B.209 INSTALL 74 FEET OF 4 INCH POLY MAIN AND RETIRE 74 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
92 COMMISSION OF TEXAS RULE B.209 INSTALL 268 FEET OF2 INCH POLY MAIN, RETIRE 268 FEET DF2 INCH STEEL MAIN, AND 5 SERVICES IN ACCORDANCE WITH
293 RAILROAD COMMISSION OF TEXAS :RULE B.209 INSTALL 119 FEET OF2 INCH POLY MAIN, RETIRE 119 FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITK
267 RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 758 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH
60 RAJLROA!l COMMISSION OF TEXAS RULE B,209 INSTALL 580 FEET OF 2 INCH POLY MAIN AND RETIRE 590 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
128 COMMISSION OF TEXAS RULE 8.209 INSTALL 320 FEET OF 4 INCH POLY MAIN AND RETIRE 320FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
170 COMMISSION OF TEXAS RULE 8.209 INST ALL 409 FEET OF 4 INCH POLY MAIN, INSTALL 63 FEET OF 3 INOKPOLY MAJN. RETIRE 409 FEET OF6 INCH STEEL MAIN, AND 63 FEET OF 4 INOK STEEL MAIN IN ACCORDANCE WITH
343 RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 42 FEET OF 3 INCH STEEL MAIN AND RETIRE 42 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
20 COMMISSION OF TEXAS RU!.E 8,209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
9 COMMISSION OF TEXAS RULE 6.209 INSTALL 92 FEET OF 2 INCH POLY MAIN AND RETIRE 92 FEET OF 2 INCH STEEL M/\IN IN ACCORDANCE WITH RAILROAD
6 COMMISSION OF TEXAS RUl.E 8.209 INST ALL 12 FEET OF 4 INCH POLY MAIN ANO RETIRE 12 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE W!TH RAILROAD
27 COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 4 INCH STEEL MAIN AND RETIRE 20 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
42 COMMISSION OF TEXAS RULE 8.209 INSTALL 203 FEET OF 2 INCH POLY MAJN ANO RETIRE 203 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
44 COMMISSION OF TEXAS RULE B.209 INSTALL 65 FEET OF 2 INCH POLY MAIN AND RETIRE 65 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITK RAILROAD
92 COMMISSION OF TEXAS RULE B.209 INSTALL 188 FEET OF 2 INCH PO!.Y MAIN, RETIRE 188 FEET OF 2 INCH STEEL MAIN, AND 4 SERVICES IN ACCORDANCE WITH
37 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 16'3 FEET OF 4 INCK POLY MAIN AND RETIRE 184 FEET OF 6 INCK STEEL MAIN IN ACCORDANCE WITH RAILROAD
108 COMMISSION OF TEXAS RULE 8.209
INSTALL334 FEET OF 2 INCH POLY MAIN, RETIRE334 FEETOF2 INCH STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE
186 WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL588 FEETOF2 INCH POLY MAIN, RETIRE 5B8FEETOF2 INCH STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE
244 WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
3 COMMISSION Of TEXAS RULE 8,209
117
31
14
116
211
21
INSTALL21 FEET OF 3 !NCH POLY MAIN AND RETIRE21 FEETOF3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 70 FEET OF 4 INCH POLY MAIN, RETIRE 70 FEET PF 3 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a,2.09 INSTALL 5 FEET OF 2 INCK POLY MAIN, RETIRE 5 FEET OF 2 INCH PVC M~N. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 16 FEET OF 6 INCH POLY MAIN AND RETIRE 16 FEET OF 6 INCH STEEL MAJN IN ACCOROANOE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 17 FEET OF 2 INCH STEEL MAIN ANO RETIRE 17 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITK RAJLROAD COMMISSION OF TEXAS RULE 8.209
WTX AddltlQHS Page24af98
BENEFITED
ALL-MIX
A!.L-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
AL!.- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
DATE PLACED'" GAs PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DMSJON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTIOM INTEGRrTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 Tl'XAS PIVlSION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 IE:XAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM !NTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST[1)
.. , 030.27140 37
982 030.27155 62
983 030.27156 33
984 030.27160 10
9B5 030,27169 1
986 030.27180 79
987 030.27181 2,698
988 030.27215 87
989 030.27217 25
990 030.27240 42
B91 030.27241 26
992 030.27269 7B
993 030.27272 143
994 030.27285 87
995 00-0.27315 130
996 030.27332 68
997 030.27342 3B
99S 030.27346 31
999 030.27347 24
1000 030.27348 19
1001 030.273.50 19
1002 030.27352 59
1003 oao.21354 19
1004 030.27357 89
1005 030.27369 93
1000 030.2.7370 89
1007 030.21a11 71
100B 030.27372 102
1009 030,27374 2B
1010 030.27385 28
1011 030.27387 75
1012 030.27368 26
1013 030.27392 215
1014 030.27398 383
1015 030.27406 9
1016 030.27424 30
ALLOCATED COST
37
62
33
10
1
79
2,698
87
25
42
26
78
143
87
130
68
38
31
24
19
19
59
19
89
93
BB
71
102
2B
28
75
26
215
383
ATMOS fNfRGYCORPORJ\TION, WESTTEXJ\S DIVISION !NT:ERIM COST RECOVERY A.NO RATE ADJUSlMENT REPORT
PFIOJl;:Cf REPORT Cf 2016
DESCRIPTION OF COMPLETED PROJECTS OEOICATED TO CUSTOMERS PUBLIC USE IN CALENDAR VEAR 2016 [21 BENEFITED
INSTAll253 FEET OF2 INCH POLY MAIN, RETIRE 253 FEET Of 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX INSTALL 14 FEET OF 4 INCH POLY MAIN AND RETIRE 14 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of Tl'XAS RULE 8,200 All-MIX INSTALL 71 FEET OF 2 INCH POLY MAIN, RETIRE 71 FEET OF2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WIT!l RAILROAD COMMISSION OF TEXAS RULE B.209 At.L-MIX INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE B.209 ALL-MIX RETIRE 11FEl'T OF 1 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.20ll All-MIX INSTALL 19 FEET OF 4 INCH STEEL MAIN, RETIRE 19 FEET OF4 INCH STEEL MAIN, AND 1 SERV!CE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.200 ALL-MIX INSTALL 3'l89FEl'T OF 4 INCH POLY MAIN, INSTAll 1490 FEET OF 2 INCH POLY MAIN, RETIRI' 5079 FEET OF STEEi. MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX INSTALL 147 FEET OF 2 INCH POLY MAIN AND RETIRE 147 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 All-MIX INST ALL 20 FEET OF 3 INCH STEEL MAIN AND RETIRE 20 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALI_-11.IX INSTALL 247 FEET OF 2 INCH POLY MAIN, RETIRE247 FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 135 FEET OF 4 INCH POLY MAIN, RETIRE 135 FEET OF 3 INCH STEEL MAIN, AND 2 SERVICIOS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 16 FEET OF 3 INCH POLY MAIN AND RETIRE 16 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 16FEET OF 4 INCH POLY MAIN, INSTAl1_31 FEET OF2 INCH POLY MAIN, AND RETIRE 37 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF Tl'XAS RULE 8,209 All-MIX INST All 27 FEET OF 6 INCH STEEL MAIN AND RETIRE 27 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 27 FEET OF 3 INCH POLY MAIN AND Rl'TIRE 27 FEET OF 3 INCH STEEL MAIN IN ACCORDANCI' WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 387 FEET OF 2 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX INSTALL 22 Fl'ET OF 2 INCH STEEL MAIN. RETIRE 22 FEET Of 2 INCH STER MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL" MIX INSTALL 7 FEET OF 2 INCH POLY MAIN, RETIRE 7 FEET OF 2 INCH PVC MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a_209 ALL-MIX INSTALL 15 FEET OF 0.75 INCH POLY MAIN ANDRl'TIRE 15 FEET OF 1.25 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 ALL-MIX INST ALL 6 FEET OF 2 INCH POLY MAIN. RETIRE 6 FEET OF 2 INCH PVC MAIN. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 6 FEET OF 2 INCH POLY MAIN, RETIRE 6 FEET OF 2 INCH PVC MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2.09 ALL· MIX INST ALL 4 Fl'ET OF 2 INCH POLY MAIN, RETIRE 4 FEET OF 2 INCH PVC MAIN AND 1 Sl'RVICI' IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 15 FEET OF 2 INCH POLY MAIN AND RETIRE 15 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
INSTALL 11 FEET OF a INCH STEEL MAIN, INSTALL9 FEET OF2 INCH STEEL MAIN. RETIRE 11 FEET OF 3 INCH STEEL MAIN, AND RETIRE 9 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX INSTALL255 FEET OF 2 INCH POLY MAIN, INSTALL 69 FEET OF 1.25 lr.ICH POLY MAIN, RETIRE324 FEET OF 2 INCH STEl'LMAIN AND 6 SERVICES IN ACCORDANCE WITH RAllROAC COMMISSION OF TEXAS RULE a_209 ALL-MIX INSTAll 215 FEET OF2 INCH POLY MAIN, RETIRE 168 FEET OF 2 INCH STEEL MAIN, RETIRE 47 FEET OF 1 INCH STEEL MAIN, AND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALI_ 115 FEET OF 2 INCH POLY MAIN, RETIRE 115 FEET OF 2 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.200 ALL· MIX INSTALI_ 120 FEET OF 2 INCH POLY MAIN, RETIRI' 120 FEET OF 2 INCH STEEL MAIN, AND 4 SERVICES IN /\CCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE B,209 ALL-MIX INSTALL 131 FEETOF2 INCHPOLY MAIN, RETIR6131 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 140 FEET OF 4 INCH POLY MAIN, RETIRI' 140 Fl'l'T OF 3 INCH STEEL MAIN, ANO 4 SERVICES IN ACCDRDANCI' WITH RAILROAD COMMISSION OF TEXAS RULE 8-209 All-MIX REPLACE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of Tl'XAS RU!.!' B.209 All-MIX INST ALL 72 FEET OF 4 INCH POLY MAIN AND RETIRE 72 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
INSTALL 75 FEl'T OF 4 INCH POLY MAIN, lNSTALL 20 FEET OF 2 INCH STEEL MAIN, RETIRE 75 FEET OF 3 INCH STEEL MAIN, AND Rl'TIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCDRDANCI' WITH RAILROAD
9 COMMISSION Of TEXAS RULE 8.209 ALL-MIX
30 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTXAdditions fl'age 25 of9R
All-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE Of PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRJ1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION svsn;M INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY"2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS D!VlStON SYSTEM INTEGRITY MAY-2016
030 TEXAS DiVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAs DIVISION SYSTEM INTEGRITY MAY-2010
030 TEXAS DIVISION SYSTl'M INTl'GRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ~2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
' 030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 Ti=XAS DIVISION SYSTEM INTEGRITY MAY~2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTl'M INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSlON SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1) COST
1017 030.27434 91 91
1018 030,27444 56 56
1019 030.27455 53 53
1020 030.27457 63 63
1021 030.27484 27 27
1022 030.27496 85 85
1023 030.27507 75 75
1024 030.27515 31 31
1025 030.27516' 398 398
1026 030.27517 74 74
1027 030.27516 55 56
1028 030.27530 26 28
1029 030.27531 17 17
1030 030.27533 54 54
1031 030.27535 53 53
1032 030.27543 255 255
1033 030.27549 137 137
1034 030.27558 89 89
1035 030.27560 228 228
1036 030.27561 99 99
1037 030.27569 10 10
1038 030.27570 9 9
1030 030.27571 39 39
1040 030.27576 19 19
1041 030.27578 29 29
1042 030.27581 62 62
1043 030.27582 62 62
1044 030.27684 50 50
1045 030.27598 24 24
1046 030.27589 50 50
1047 030,27593 23 23
1048 030.27596 73 73
1049 030.27602 48 48
1050 030.27603 28 28
1051 030.27605 18 18
1052 030.27608 14 14
1053 030.27613 8 8
1054 030.27615 10 10
1055 030.27616 12 12
ATMOS EN!:;ftGYCORPORATION, WEST TEXAS DIVIS101'4
INTE~ll'vl COST RECOVERY ANO RATE AD.flJSIMiENT REPORT
PROJECT REPORT C.Y 2016
DESCR!PT!ON DF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (21
INSTALL 45 FEET OF 4 INCH STEEL MAIN, R!OTIRE 45 FEET OF 4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULi; 8,209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 8 FEET OF 2 INCH POLY MAIN. RETIRES FEET OF 2 INCH PVC MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 19 FEET OF 3 ]NCH :POLY MAIN ANO RETl.RE 19 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 15 FEET OF 2 INCH POLY MAIN ANO RETIRE 15 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 26FEET OF 4 INCH STEEl MAIN, RETIRE 28 FES" Of 4 INCH STEEL MAIN. AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUlE 6.209 INSTALL 37 FEET OF 2 INCH STEEL MAIN, RETIRE 37 FEET OF 2 INCH STEEL MAIN, ANO 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1016 FEET OF 2 INCH POLY MAIN. RETIRE 1016 FEET OF 2 INCH STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 12FEET OF4 INCH STEEL MAIN, RETIRE 12FEETOF 4 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WIT!1 RAILROAD COMMISSION OF TEXAS RULE 8.200 INSTALL 32 FEET OF 3 INCH STEEL MAIN, RETIRE 32 FEET OF 3 lNCH STEEL MAIN ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RULE 8.200 INSTALL 12 FEET OF 2 INCH POLY MAIN AND RETIRE 12 FEET OF 2 !NCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S.209 INSTALL 107 FEET OF 2 INCH POLY MAIN. RS-IRE 107FEET OF 2 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 100FEETOF2 INCH POLY MAIN, RETIRE 100FEETOF2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S,2.09 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 10 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 357FEET DF2 fNCHPOLY MAIN, RETIRE 357 FEET OF3 INCH STEEL M~N. ANO 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 13 FEET OF 3 INCH STEEL MAIN, RETIRE 13 FEET OF 3 INCH STEEL MAIN, AND 2 SERVICES IN AGCORDANCE Wl-rn RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 143 FEET OF 4 INCH POLY MAIN. INSTALL 65 FEITT OF 2 INCH POLY MAIN. RETIRE 143 FEET OF 4 INCH STEEL MAIN, RETIRE 65 FEET OF 2 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 33 FEET OF 3 INCH POLY MAIN, RETIRE33fEET DF2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.20:9 INSTALL 70 FEET OF 2 INCH POLY MAIN, RETIRE 72FEET OF2 INCH STEEL MAIN AND 3 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RlJLE 8.209 INSTALL 86 FEET OF 2 INCH POLY MAIN, RETIRE SS FEET OF2 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OFlEXAS RULE B.209 INSTALL 40 FEET OF 3 INCH MAIN AND 1 SERVICE AND RETIRE 40 FEET OF 3 INCH MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 115 FEET OF 2 INCH POLY MAIN, RETIRE 115 FEET OF 2 INCH STEEL MAIN AND 2 SERVJCES IN ACCORDANCE WITH RAILROAD COMMl:SSJON OF TEXAS RULE B.209 INSTALL 20 FEET OF 2 INCH SlEEL MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2B FEET OF 4 INCH STEEL MAIN, RETIRE 28 FEET OF 4 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 220 FEET OF 4 INCH POLY MAIN AND RETIRE 228 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8,209 INST ALL 224 FEET OF 2 INCH POLY MAIN AND RETIRE 224 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE wm1 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 15 FEETOF21NCH POLY MAIN, INSTALL 71 FEET OF 1.25 INCH POLY MAIN, AND RETIRE B6 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6,209
INSTALL 74 FEET OF 2 INCH POLY MAIN ANO RETIRE 74 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 30 FEET OF 2 INCH POLY MAIM AND RETIRE 30 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE wmi RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD CDMMISSIONOFTEXAS RULE 8.209 INSTALL 17FEET OF2 INCH POLY MAIN AND RETIRE 17 FEET OF2 INCH STEEL MAIN IN ACcORDl\NCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL SO FEET OF 2 INCH POLY MAIN, RETIRE 60 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTXAddltlDM5 Page 26 of 9:8
CUSTOMERS BENEFITED
ALL· MIX
ALL· MIX
All-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL- MfX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MJX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL· MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL- MIX
ALL-MIX
ALL-MIX
All-MIX
DATE PLACED IN' GAS PLANT IN
LOCATLON PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTCM INTEGRITY MAY-2016
030 TEXAS DMSlON SYSTEM INTEGRrTY MAY-201S
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2.016
0:30 Tf:XAS DMSION SYSTEM INTEGRITY MAY·2016
030 TEXAS DilllSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVJSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER • 2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTCGRITY MAY.2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTCM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DfVISlON SYSTEM INTCGRITY MAY-201S
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-W16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXl\S DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST{1}
1056 030,27617 82
1057 030.27619 11
1058 030.27622 (1)
1059 030.27626 79
1060 030.27627 130
1061 030.27628 64
1062 030.27629 45
1083 030.27630 127
1064 030.27632 366
1065 030.27633 406
1066 030.27634 175
1067 030.27638 39
1006 030.27640 26
1069 030.27641 444
1070 030.27642 221
1071 030.27643 334
1072 030.27645 30
1073 030.27648 22
1074 030.27649 63
1075 030.27650 16
1076 030.27652 22
1077 030.27653 90
1078 030.27861 16
1079 030.276"33 a
1060 030.27664 49
1081 030.27667 73
1082 030.276"69 44
10BJ 030.27571 4
1084 030.27673 16
10Bfi 030.27677 18
1086 030.27680 28
I
1087 030.27681 120
1088 030.27682 121
1089 030.27684 250
1090 030.27685 311
10g1 030.27686 318
1092 030.27686 33
ATMOS ENFRGV CORPORATION, WESTT!XAS OIVISIOll lNTE"RIM COST RECOVERY AND RA TE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
ALLOCATED DESCRIPTION OF COMPLEfEO PROJECTS DEDICATED TD CUSTOME;RS
COST PUBLIC USE IN CALENDAR YEAR 2016 (2)
INST AU. 277 FEET OF 2 INCH POLY MAIN. RETIRE 277 FEET OF 2 INCH STEEL MNN. AND ASSOCIATED SERVICES IN ACCORDANCE
82 WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
11 COMMISSION OF TEXAS RULE 8.209 INSTALL 10 FEET OF 2 INCH POLY MAIN, RETIRE 10FEETOF 2 INCH STEEL MAIN, ANO 1 SERVICE IN ACCORDANCE WITH
11) RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTAL!.117 FEETOF2 INCH POLY MAIN. RETIRE 117 FEETOF2 INCH >m;EL MAIN. AND 3 SERVICES IN ACCORPA.'!CE WITH
79 RAILROAD COMMISSION OF TEXAS RUl.E 8.209 INSTALL 117 FEET OF21NCH POLY MAIN, RETIRE 117 FEET OF2 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH
130 RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 260 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH
64 RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTAl.l B FEET DF 2 INCH STEEi. MAIN, RETIRE a FEET DF 2 INOH STEEi. MAIN. AND 2 SERVICES IN ACCORDANCE WITH RAILROAD
45 COMMISSION OF TEXAS RULE 8.209 INSTALL 127 FEET OF 2 INCH POI. Y MAIN AND RETIRE 127 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
127 COMMISSION OF TEXAS RULE 8.209 INSTALL 636 FEETOF2 INCH POLY MAIN, RETIRE 638 FEET OF2 INCH STEEL MAIN AND 14 SERVICES IN ACCORDANCE WITH
366 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 565 FEET 0 F 4 INCH POLY MAIN AND RETIRE 585 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RNLROAD
406 COMMISSION OF TEXAS RULE 6.21>9 INST ALL 478 FEET OF 2 INCH POLY MAIN AND 14 SERVICES AND RETIRE 478 FEET OF 3 INCH STEEL MAIN AND 14 SERVICES IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TEXAS RULE
175 6.21>9 INSTALLS FEET OF 3 INCH STEEL MAIN AND RETIRE 5 FEEf OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
39 COMMISSION OF TEXAS RULE 8.209 INSTl\Ll9 FEET OF 3 INCH STEEL MAIN AND RETIRE 9 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
26 COMMISSION OF TEXAS RULE 8.209 INSTALi. 1020 FEET OF 2 INCH POLY MAIN AND 7 SERVICES AND RETIRE 978 FEET OF 2 INCH STEEL MAIN AND 7 SERVICES IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
444 6.209
INSTALL427 FEET OF 2 INCH POLY MAIN, RETIRE 427 FEET OF 2 INCH STEl;L MNN, AND ASSOCIATED SERVICES IN ACCORDANCE
221 WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL643 FEET OF 2 INCH POLY MAIN AND RETIRE 643 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAl!.RDAD
334 COMMISSION OF TEXAS RULE 8.209 INSTALL40FEET OF2 INCH POLY MAIN AND RETIRE40FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
30 COMMISSION OF TEXAS RULE 6.209 INSTALL 120 FEET OF 2 INCH l'OLY MAIN, RETIRE 120 FEEf OF 2 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH
22 RNLROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD
63 COMMISSION DF TEXAS RULE a,209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
16 COMMISSION OF TEXAS RULE 0.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
22 COMMISSION DF TEXAS RULE a.209 RETIRE 10 FEET O~ STEEL SERVICE. IN ACCORDANCE WITH
90 RAILROAD COMMISS!ON OF TEXAS RULE 13.209 INSTALL ao FEET OF 2 INCH STEEL MAIN AND RETIRE ao FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
16 COMMISSION OF TEXAS RULE 8.209 INST ALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
;e COMMISSION OF TEXAS RULE. 8_2.09 INST AL!. 6 FEET OF 4 INCH STEEL MAIN ANO RETIRE 6 FEET OF 4 INCH STEEL MA!N JN ACCORDANCE WITH RAILROAD
49 COMMISSION OF TEXAS RULE 8.209 INSTALL 9 FEET OF 6 INCH STEEL MAIN AND RETIR>; 9 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
73 COMMISSION OF TEXAS RULE 8.2<l9 INST ALL 10 FEET OF 2 INCH STEEL MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RNLROAD
44 COMMISSION DF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
4 COMMISSION OF TEXAS RULE 8.209
16
18
28
121l
121
250
311
318
33
INSTALL 101 FEET OF2 INCH POLY MAIN, RETIRE 101 FEET OF2 INCH SlEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE B.209 INST ALL 61 FEET OF 2 INCH POLY MAIN, RETIRE 61 FEET OF 2 INCH STEEL MA1N. ANO 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 360 FEET OF 2 INCH POLY MAIN AND RET~RE 360 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL22 FEET OF 4 INCH STEEL MAIN AND RETIRE 22 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALi. 455 FEET OF 2 INCH POLY MAIN AND RETIRE 455 FEET DF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RIJLE 8.209 INSTALL 10 FEET OF3 INCH STEEL MAIN, INSTALL 103 FEETOF2 INCH PDLY MAIN, RETIRE 10 FEET OF 3 INCH STEEL MAIN, RETIRE 103 FEET OF 2 INC!1 STEEL MAIN, AliD 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E B.209 INSTALL 263 FEET OF 4 INCH POLY MAIN AND 1 REGULATOR STATION, RETIRE 263 FEET DF 4 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALI. 34 FEET OF 2 INCH POLY MAIN AND RETIRE 34 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WIX Addttlons P.age27of9B
BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALl.-MIX
ALL· MIX
ALL-MIX
ALL-MIX
AL!.·MIX
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALl.-MIX
ALL-MIX
All- MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All· MIX
ALL· MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACcu lN
GAS PLANT IN LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 H'XAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS PIV!SIDN SYSTEM INTEGRITY MAY-2016
O:ID TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 T!'XAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2<l16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM JNTEGRiTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ND. PROJECT NUMBER COSTj1)
1093 030.27695 1SB
1094 030.27701 38
1095 030.27702 45
1096 030.27708 45
1097 030.27714 7
1098 030.27733 38
1099 030.27751 35
1100 030.27752 31
1101 030.27756 28
1102 030.27758 53
1103 030.27759 28
1104 030.27766 191
1105 030.27771 40
1106 030.27772 40
1107 030.27773 23
1106 030.27774 97
1109 030.27776 429
1110 03-0.27779 72
1111 030.27781 20
1112 030.27783 22
1113 030.2nM 21
1114 030.27785 71
1115 030.27700 39 !
1116 030.27805 50
1117 030.27806 9
1116 030.27607 56
1119 030.27813 62
1120 030.27814 16
11:21 030.27616 47
1122 03-0.27832 29
1123 030,27634 56
1124 030.27835 126
1125 030.27850 9
1126 030.27852 67
1127 000.27859 14
1128 030.27861 122
1129 030.27862 14
1130 030.27871 21
ATMOS ENERGY CORPORAnON, WEST TEXAS DIVISION INTE"RlM COST RECOVERY AND RATE A.OJUSTMENT REPORT
PROJECT REPORT CV 2016
ALLOCATED DESCRIPTION OF COMPUoTED PROJECTS DEDICATED TO CUSTOMERS COST PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTl\l.L 92 FE~ OF 6 INCH STEEL MAIN, RETIRE 92 FEET OF 6 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WJTH
168 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTl\l.L40 FEET OF21NCH STEEL MAIN, RETIRE 40 FEETOF2 INCH STEEL MAIN, AND 1 SERVICE IN ACCOROANCE WITH
38 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 174 FEET Of 2 INCH POLY MAIN, RETIRE 174FEETOF2 INCH STEEL MAIN, AND 4 SERVICES IN ACCORDANCE WITH
45 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 100FEET OF2 INCH POLY MAJNAND RETIRE 100 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
45 COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
7 COMMISSION OF TEXAS RULE 8.209 INSTALL341 FEET OF2 INCH POLY MAIN, RETIRE 341 FEET OF3 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH
38 RAllROAD COMMISSION OF TEXAS RULE 8.209 RETIRE ONE SERVICE IN ACCORDANCE WITH RAILRAOD
35 COMMISSION OF TEXAS RULE 6.209 INST All 9 FEET OF 3 INCH POLY MAIN AND RETIRE 9 FEET OF 3 INCH STEEL MAJN IN ACCORDANCE WITH RAILROAD
31 COMMISSION Of TEXAS RULE 8.209 INSTALL 10FEETOF2 INCH POLY MAIN AND RETIRE 10FEETOF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
28 COMMISSION OF TEXAS RULE 8.209 INSTALL 36 FEET OF 2 INCH STEEL MAIN, RETIRE 36 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH
53 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 30 FEET OF 2 INCH POLY MAIN AND RETIRE 30 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
28 COMMISSION Of TEXAS RULE 8.209
INSTALL 247 FEET OF 4 lNCH POLY MAIN, INSTALL 111 FEET OF 1.25 INCH POLY MAJN. RETIRE 247 FEET OF 4 INCH STEEL MAIN. AND RETIRE 111 FEETOF2 INCH STEEL MAJN INACCOROANCE
191 WITH RAILROAD COMMISSION Of TEXAS RULE 8,209 REPLACE 1 SERVICE IN ACCORDANCE WIT}j RAILROAD
40 COMMISSION OF lEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE; WIIB RAILROAD
40 COMMISSION Of TEXAS RULE 8,209 INSTALL 10 FEET OF 2 INCH POLY MAIN AND RETIRE 10 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
23 COMMISSfON OF TEXAS RULE 6.209 INSTl\l.L 10 FEETOF2 INCH STEEL, RETIRE 10 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE lN ACCORDANCE WITH RAILROAD
97 COMMISSION OF TEXAS RULE 8.209 INSTALL 1888 FEET OF2 INCH POLY MAIN, INSTALL450 FEET OF 1.25 INCH POLY MAIN, RETIRE 3268 FEET OF 2 INCH STEEL MAIN, RETIRE 6'164 FEET OF 2 INCH ABS MAIN, AND AsSOCIATED SERVICES IN ACCORDANCE WITH RAIUlOAD COMMISSION OF
429 TEXAS RULE 6.209 INST /ILL 128 FEET Of 1.25 INCH Pol. Y MAIN AND RETIRE 132 FEET Of 2 INCH STEl'L MAIN IN ACCORDANCE WITH RAILROAD
72 COMMISSION OF TEXAS RULE 8.209 INST ALL 40 FEET OF 2 ~NCH STEEL MAIN ANO RETIRE 40 FEa OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
20 COMMISSION OF TEXAS RULE 8.209 INSTALL 32 FEET OF 2 INCH POLY MAii>! AND RETIRE 32 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
22 COMMISSION OF TEXAS RULE 8.209 INSTALL 22 FEET OF 2 INCH POLY MAJN, RETIRE 22 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
21 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL21 FEET OF3 INCH POLY MAJNAND RETIRE21 FEET OF S INCH STEEL MAtN IN ACCORDANCE WITH RAil.ROAD
71 COMMISSION OF TEXAS RULE 8.209 INSTALU39 FEET OF 1 !NCH POLY MAIN AND RETIRE 89 FEET OF 2 INCH STEEL MAIN !N ACCORDANCE WITH RAILROAD
39 COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD
50 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
9 COMMISSION OF TEXAS RULE 8.209
58
62
16
47
29
56
126
9
DI
14
122
14
21
INSTALL 36 FEET OF 2 INCH POLY MAIN ANO RETIRE 36 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WiTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 103 FEET OF 2 INCH POLY MAIN AND RETIRE 100 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INST 1\1.L 21 FEET OF 2 INCH STEEL MAIN AND R~IRE 21 FE~ OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 10 FEET OF 2 lNCH POLY MAIN, RETIRE 10 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLAC!O 1 SE;RVICE IN ACCORDANCE WrTH RAILROAD COMMISSION OF TEXAS RULE. a.209 INSTALL 18 FEET Of 2 INCH STEEL MAIN AND RETIRE 18 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 140 FEET OF 4 INCH POLY MAIN /IND RETIRE 140 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 104 FEET OF 3 INCl1 POLY MAIN AND RETIRE 104 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE JN ACCORDANCE WiTH RAILROAD COMMlSSION OF TEXAS RULE B.209 INSTALL 101 FEB OF 2 INCH STEEL MAIN AND 2 SERVICES AND RE.TIRE 101 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 105 FEET OF POLY MAIN AND 1 SERVICE AND RETIRE 105 FE~ OF2 INCH STEEL MAJN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTXAdd~tfa.n$
Page28of98
BENEFITED
ALL-MIX
ALL- MIX
ALL-MIX
ALL· MIX
AlL-MIX
111.L-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MiX
All-MIX
ALL-MIX
ALL-MlX
All-MIX
ALL-MIX
All- MIX
ALL-MIX
ALL· MIX
ALL-MIX
1\1.L-MIX
ALL-MIX
/\LL-MIX
PATE PLACED IN GASPLANTIN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DMSJON SYSTEM INTEGRITY MAV-2010
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-~16
o;iO TEXAS DIVISION SYSTEM INTEGRITY MllY-2016
000 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DiVJSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRJTY MllY-2016
030 TEXAS DIVISION SYSTEM !NTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TCXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM JNTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OSO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRtTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-~16
030 TEXAS DlVlSION SYSTEM INTEGRITY MAY-~16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIViSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-~16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST(1)
1131 030.27872 49
1132 030.27873 96
1133 030.27884 Bo
1134 030.27885 35
1135 030.27666 331
1136 030.21867 82
1137 030.276B9 23
1138 030:27693 16
1139 030.27901 193
1140 0'30,;;!7906 45
1141 000.27907 49
1142 030.27911 41
1143 030.27912 78
1144 030.27926 116
1145 o:m.27932 299
1146 030.27945 42
1147 03-0.27964 79
1146 030.27969 16
1149 030.27970 59
1150 030.27972 24
1151 030.27977 296
1152 030.28000 57
1153 030.28002 29
1154 030.28003 24
1155 030.28005 21
1156 030.28006 15
1157 030.28007 54
1158 030.28011 45
1159 030.28015 8
1160 030.28010 28
1161 030.28017 28
1162 030.28022 27
1163 030.28023 46
1164 030.28026 37
1165 030.28026 37
1166 0'30.2802.7 57
1167 030.28040 44
ALLOCATED COST
49
96
85
35
331
82
23
16
193
4o
49
41
76
116
299
42
79
16
59
24
296
57
29
24
21
15
54
46
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION INTERIM COST RECOVERY AND RAH ADJUSTMENT REPORT
Pf\OJECT R[PoRT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATEO TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 {2) BENEFITED
INSTALL 26 FEET OF 3 INCH STEEL MAIN, RETIRE 26 FEET OF 3 lNCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 73 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES AND RETIRE 73 FEET OF STEEL MAIN ANO 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX INSTALL 10 FEET OF 8 INCH STEEL MAIN AND RETIRE 10 FEET OF B INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST All 70 FEET Of 2 INCH POLY MAIN AND RETIRE 70 FEET OF 3 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX
INSTALL 996FEET OF2 !NCH POLY MAIN, RETIRE 99B FEET OF3 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 All-MIX
INSTALl416FEETOF2 INCH POLY MAIN, RET1RE416 FEETOF3 INCH STEEL MAIN, ANO ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 All-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 137 FEET OF 2 INCH POLY MAIN AND RETIRE 137 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX INSTALL 50 FEET OF 3 INCH POLY MAIN. RETIRE50FEET OF3 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 26 FEET OF 4 INCH POLY MAIN AND RETIRE 26 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL 131 FEET OF 2 INCH POLY MAIN AND RETIRE 131 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX INSTALL 49 FEET OF 6 INCH STEEL MAIN, RETIRE 49 FEET OF 6 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITI-1 RAILROAD COMMISSION OF TEXAS RULE 8.209 All· MIX
INSTALL66 H'ETCF6 INCH POl-YMAIN, INSTALL 13 FEETOF4 INCH POLY MAIN. RETIRE 66 FEET Of B INCH STEEL MAIN, AND RETIRE 13 FEET Of 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RUl-E 6.209 ALL-MIX INSTALL 500 FEET OF 1 INCH POLY MAIN AND RETIRE oOO FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL21 FEETOF31NCH STEEL MAIN, RETIRE21 FEET OF 3 INCH STEEL MAIN, ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 251 FEET OF 2 INCH POLY MAIN, INSTALL 85 FEET OF 1.25 INCH POLY MAIN, RETIRE336FEET CF2 INCHSTEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX RETIRE 71 FEET OF 6 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL 23B FEET OF 2 INCH POLY MAIN, RETIRE 238 FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
INSTALL 679 FEET OF 2 INCH POLY MAIN, RETIRE 679 FEET OF 3 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 102 FEET OF 1.25 INCH POLY MAIN AND RETIRE 102 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE e.209 ALL-MIX INSTALL 21 FEET OF 2 INCH STEEL MAIN AND RETIRE 21 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 344 FEET Of 2 INCH POLY MAIN ANO RETIRE 225 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE ll'Y ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 S!ORVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 173 FEET OF 4 INCH POLY MAIN, RETIRE 173fl=ET OF 3 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDAMCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 15 FEET OF 3 INCH STEEL MAIN, RETIRE 15 FEET OF3 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD
8 COMMISSION OFTEXASRULE8.209 ALL-MIX
28
28
27
46
37
37
57
44
RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 2 STEEL SERVICES lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTAll 174 FEET OF2 INCH POLY MAIN, INSTALL 56 FEET OF2 INCH STEEL MAIN, RETIRE 230 FEET OF 2 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 18 FEET Of 3 INCH STEEL MAIN ANO RETIRE 18 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RLil-E 8.209 INSTALL 18FEETOF2 INCH POLY MAIN AND RETIRE 18 FEETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 40 FEET OF J INCH STEEL MAIN AND RETIRE40FEET OF 3 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 79 FEET Of 2 INCH POLY MAIN AND RETIRE 79 FEET OF 2 INCH STEEi. MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 14 FEET OF 3 INOH STEEL MAIN AND RETIRE;14FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl-E B.209
WTXAddftfa.n$ PageZ9cf98
ALL- MIX
ALL-MIX
ALL· MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS PIVlSION SYSTEM INTEGRITY MAY-2016
0'30 TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DiVJSION SYSTEM INTEGRITY MAY-2016
030 lEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION sYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-201S
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
0'301EXAS DMSION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY~2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST(11
116"8 0:30.28048 21
1169 030.26049 00
1170 030.26050 6
1171 030.28057 459
1172. 030.26063 154
1173 030.28066 5,348
1174 030.28083 76
1175 030.280:84 14
1176 030.28089 8,901
1177 030.28100 102
1178 030.26101 06
1179 030.28107 689
i1BO 030.28109 433
1161 030.28116 744
1182 030.28117 4
1183 0'30.28119 31
1164 030.28120 55
1186 030.28129 10,608
1186 030.28132 2.440
1187 030.28137 16
1186 030.28136 24
1169 030.28139 22:2
1190 030.26143 12'3
1191 030.28147 31
1192 030.28149 23
1193 030.26151 42
1194 030.28152 32
1195 030.28153 188
1196 OJ°-28155 16
1197 030.26156 227
1198 030.28160 500
1199 030.28161 40
1200 030.28162 480
1201 030.28163 236
1202 030.28168 34
ALLOCATED COST
21
86
ATMOS ENERGY CORPORATION, WfST TEXAS DIVISION INTERIM COST RECOV£ftV AND RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBl.IC USE IN CALENDAR YEAR 2010121 BENEFITED
INSTALL 17 FEETOF2 INCH POLY MAIN AND RETIRI' 17 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WffH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 203 FEET OF 2 INCH POLY MAIN. RETIRE 203 FEET OF 2 INCH STEEL MAIN, AND 4 SERVICES IN ACCORDANCE wnH RAtlROAD COMMISSION OF lEXAS RULE 8.209 ALL-MIX REP!..ACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
8 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL30FEET DF6 INCHSTEEL MAIN, INSTALL 414 FEET OF 2 INCH POLY MAIN, RETIRE 30 FEET OF 6 INCH STEEL MAIN, RETIRE 414 FEET OF 3 INCH STEEL MAIN, AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
459 B.209 INSTALL 71 FEET OF 4 INCH STEEL ANO RETIRE 71 FEET OF 4 !NCH STEEL IN ACCORDANCE WITH RAlLROAD COMMISSION OF
154 TEXAS RULE 8.209 INSTALL 15751 FEET OF2 INCll POLY MAIN, RETIRE 19121 FEET OF 6 INCH. 4 INCH. 3 INCH AND 2 INCH STEEL MAIN AND 363 AsSOCIATED SERVICES IN ACCCORDANCE WITH RAILROAD
5,348 COMMISSION OF TEXAS RULE 8.209 INSTALL 340 FEET OF 2 INCH POLY MAIN AND RETIRE 340 FEET OF 42 INCH STEEL MAIN IN ACCORDANCE WITK RAILROAD
76 COMMISSION OF TEXAS RULE B.209 INSTALL 113 FE;ETOF2 INCH POLY MAIN. RETIRE 113 FEET OF 2 INCH STEEL MAIN, AND 1 Sl'RVICE IN ACCORDANCE WITH
14 RAILROAD COMMISSION OF TEXAS RULE a.209 INSTALL 21.762 FEET OF 2 INCH POLY MAIN, RETIRE 24, 162 FEET OF 3 INCH STEEL, AND 238 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
8,901 B.209 INSTALL 1 OB FEET OF 2 INCH POLY MAIN, RETIRE 100 FEET OF 2 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH
102 RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 17 FEET OF 2 INCH POLY MAIN, RETIRE 17 FEET OF 2 INCH STEEL MAIN. ANO 2 SERVICES IN ACCORDANCE WITH
56 RAILROAD COMMISSION OF TEXAS RULE 8.2"9 INSTALL2250 FEET OF 2 INCH POLY MAIN, RETIRE2090 FEET OF 2 INCH STEEL MAIN AND 17 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
689 8.209 INSTALL 439 FEET OF 2 INCH POLY MAIN, INSTALL 75 FEET OF 1.25 INCH POLY MAIN, RETIRE 403 FEET OF 4 INCH STEEL MAIN, RETIRE 111 FEETOF2 INCHSTEELMAIN, AND 1 SERVICE lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
433 6.209 REP!..ACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
744 COMMISSION OF TEXAS RULE 6.209 REP!..ACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
4 COMMISSION OF TEXAS RULE 6.209
31
55
10,606
2,445
16
24
222
126
31
23
42
32
188
16
2:27
506
40
480
236
34
INSTALL40 FEET OF 2 INCH STEEL MAIN, RETIRE40 FEET DF2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 62 FEET OF 2 INCH STEEL MAIN AND RETIRE62FEETOF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 16166 FEET OF 2 INCH AND 4 INCH POLY MAN. RETIRE 18826 FEET OF VARIOUS SIZE STEEL MAIN, ANO 238 RESIDENTIAL AND COMMERCIAL SERVICESIN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 12,228 FEET OF 2 INCH POLY MAIN. RETIRE 12,699 FEET OF 2 lNCH, 3 !NCH, AND 4 INCH STEEL MAIN, AND 58 SERVlCES IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERV!CE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 168 FEET OF 2 INCH POLY MAIN. RETIRE 166 FEET OF 2 INCH STEEL MAIN. AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 42 FEET OF 4 INCH STEEL MAIN AND RETIRE 42 STEEL MAIN IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 62 H:ET OF 2 INCH POLY MAIN. RETIRE 62 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E B.209 INST ALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 107 FEET OF 2 INCH POLY MAIN, RETIRE 107 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of" TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL98 FEET OF 1.25 INCH POLY MAIN, RETIRE 96 FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL309 FEETOF2 INCH POLY MAIN, INSTALL226 FEET OF 1.25 INCH POLY MAIN, RETIRE 535 FEET OF 21NCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL514 FEETOF2 INCH POLY MAIN, RETIRE 514fEET OF2 INCH STEEL MAIN, AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 42 FEET OF 2 INCH STEEL MAIN, RETIRE 42 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 965 FEET OF 2 INCH POLY MAIN, RETIRE 716 FEET OF 4 INCH STEEL MAIN, RETIRE 249 FEET OF 3 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
INSTALL443FEET OF2 INCH POLY MAIN, RETIRE 440 FEET OF 2 INCH STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INST ALL 15 FEET OF 2 INCH STEEL MAIN AND RETIRE 15 FEET OF 2 INCfl STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE B.209
wn: Addltion5 Pag~30;i;tf98
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-M!X
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED 1111 GAS Pl.ANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 T!'XAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2Q16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2Q16
0'30 1EXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAs DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRl1Y MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016 ' 030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SVSTEM INTEGRITY MAY-201£
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201B
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM !NTEGRl"lY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST(i)
1203 030.28171 283
1204 030.28160 81
1205 030.28192 20
1206 030.28194 192
1207 030.~82{]0 5
1200 030.28202 58
1209 030.20205 166
1210 030.28207 11,533
1211 030.26226 110
1212 030.20229 90
1213 030.20230 6,960
1214 030.28232 6
1215 030.28233 80
1216 030.28236 13
1217 030.28238 45
1218 030.28242 601
1219 030.28243 179
1220 030.28383 171
1221 030.28446 62
1222 030.28488 128
1223 030.28507 8,961
1224 030.28528 88
1225 030.28529 76
122.6 030.28537 212
1227 030.28554 34
1228 030.28564 53
1229 03tl.~:B56ti 116
1230 030.26576 so
1231 030.20579 101
1232 030.2BB12 9(l
1233 030.28614 13
1234 030.28615 17
1235 030.26616 3"
1236 030.20617 12
1237 03-0.26616 22
1238 030.28619 25
1239 OJ0_2a620 45
1240 030.26621 45
1241 030.26622 29
ALLOCATED COST
203
81
20
192
5
56
166
11,533
110
90
6,960
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION JNTERIM COST ~fCOVllRY ANO MTE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMJ::fl:S PUBLIC USE IN CALENDAR YEAR 2016 [2) BENEFITED
INSTALL 209 FEET OF2 INCH POLY MAIN AND RETIRE 190 FEET OF 2 INCH AND 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RUl..f:; B.209 ALL-MIX INSTALL 65 FEET OF 3 INCH POLY MAIN AND RETIRE 65 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 All-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 All-MIX INSTALL 171 FEET OF 4 INCH POLY MAIN, RETIRE 171 FEET OF 3 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RULE 0.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 5 FEET OF 2 INCH STEEL MAIN ANO RETIRE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALi. 305 FEET OF 4 INCH POLY MAIN. RETIRE 305 FEET OF4 INCH STEEL MAIN, ANO 4 SER\/lCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 19,457 FEET OF 2 INCH POLY MAIN, RETIRE 19,457 FEET OF 3 INCH STEEL, AND 420 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 257 FEET OF 6 INCH POLY MAIN, RETIRE259 FEET OF 0 INCH STEEL MAIN AND 2 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 ALL-MIX INSTALL 14471 FEETOF2 INCH POLY MAIN, RETIRE 19182 FEET DF2 INCH, 3 INCH, 4 INCH, AND 6 INCH STEEL MAIN AND 157 RESIDENTIAL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 ALL-MIX REPLACE 1 sERVJCE IN ACCORDANCE WITH RAILROAD
a COMMISSION OF TEXAS RULE 8.209 ALL-MIX
88
13
45
601
179
171
62
128
B.961
08
78
212
34
53
116
80
101
90
13
17
36
12
22
25
45
45
29
INSTALL 5 FEET OF 2 INCH STEEL MAIN, RETIRE 5FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL52FEET DF2 INCli POLY MAIN, RETIRE 52 FEET DF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1076 FEET OF 2 INCH POLY MAIN. RETIRE 1076 FEET OF 2 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL244 FEET Of 2 INCH POLY MAIN, RETIRE244 FEETOF2 INCH STEEL MAIN, AND 6 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET OF 4 INCH STEEL MAIN AND RETIRE 6 FEET OF 4 INCH STEEL MAIN l'l ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 182 FEET OF 2 INCH POLY MAIN, RETIRE 182 FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 933<J FEET OF 2 INCH Pol V MAIN AND 4733 FEET OF 4 INCH POLY MAIN, RETIRE 14,997 FEETDF2 INCH,3 INCH ,4 INCH AND 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 13 FEET F 2 INCH STEEL MAIN AND RETIRE 13 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 14 FEET OF 3 INCH STEEL MAIN, RETIRE 14 FEET OF3 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 l'lST ALL 20 FEET OF 6 INCH STEEL MAIN AND RETIRE 20 FEET Of 6 INCH STEEL MAIN IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TEXAS RULE 0.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 43 FEET OF 2 INCH POLY MAIN AND RETIRE 43 FEET OF 2 INCH STEEL MAii" IN ACCORDANCE WITH RAILROAD COMMlSSION Of TEXAS RULE B.20:9
INSTALL 45 FEET OF 6 INCH STEEL MAIN AND RETIRE 45 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 20 FEET OF 3 INCH POLY MAIN AND RETIRE 20 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 12 FEET OF 6 INCH STEEL MAIN AND RETIRE 12FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 11 FEET OF 2 INCH STEEL MAIN AND RETIRE 11 FEET OF 2. INCH STEEL MAIN lN ACCORDANCE WiTH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WJTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 24 FEET OF 2 INCH POLY MAIN AND RETIRE 24 FEET OF 2 INCH STEEL MAIN IN ACCOROANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 44 FEET OF 4 INCH STEEL MAIN, RETIRE 44 FEET OF 4 INCli STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 33 FEET OF 2 INCH PDLY MAIN AND RETIRE 33 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUlE 8.209 INSTALL 24 FEET OF 3 INCH POLY MAIN, RETIRE 24 FEET OF 3 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 1 1.25 INCH STEEL SERVICE IN ACCORDANCE WfTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 9 FEET OF 4 INCH STEEL MAIN AND RETIRE 9 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 41 FEET DF 3 INCH STEEL MAIN AND RETIRE 41 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WlXAddiUOh~
Page 31 of9S
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
/\LL-MIX
/\LL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- M!X
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
DAIE PLACED IN GASP~NTIN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVIStDN SYSTEM INTEGRITY OCTOBER -2016
030 TEXAS DMSIDN SYSTEM JNTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISJON SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OBO TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBE:R - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRtlY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISID'l SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2.015
030 1EXAS DMSION SYSTEM INTEGRITY MAYR2.016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2015
LINE ND. PROJECT NUMBER COST(11
1242 030,28623 23
1243 030.28624 32
1244 030.28625 12
1245 0'30.28626 15
1246 030.28627 128
1247 030.28630 180
1248 030,28636 45
1249 030.28640 18
1250 030.26641 Wl
1251 a:m.2ss42 111
1252 030.28643 684
1253 030.28648 72
1254 030.20049 103
1255 030.28650 161
1258 030.28665 52
1257 030.26667 65
1258 030.28678 39
1259 030.28679 57
121;0 030.26680 49
1261 030,28681 21
1262 030.28682 32
1263 0'30.28707 41
1264 030,28726 27
1265 030.28795 31
1266 03°'28796 40
1267 030_:28797 4
1288 030.28800 20
1269 030.28602 11
1270 030.28809 15"
1271 030.28810 159
1272 030.28814 10
1273 030.28815 29
1274 030.28816 52
1275 030.28817 53
1276 030.26816 42
1277 030.26819 47
1278 o30.2Baoo 113
1279 030.28831 26
1280 OJ0.28832 63
ALLOCATED COST
23
32
12
15
128
180
45
18
19)
11
684
72
103
161
52
85
39
57
49
21
32
41
27
31
40
ATMOS ENERGYCORl'ORATION, WESTTfXAS DIVISION lNTEfl.IM CO.ST RECOVER'{ ANll JlA TE ADJUSTMENT RE:PORT
PROJECT REPORT CY 2016
OESCRIPTION OF COMPLETED PROJECTS DEOICATEO TD CUSTOMERS PUBLIC USE IN CALENDAR VEAR 2016 [2) BENEFITED
INSTALL 20 FEET Of 4 INCH POLY MAIN AND Rl'TIRE20 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 SERVICE IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE B.200 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.200 ALL-MIX INSTALL 15 FEET OF 4 INCH POLY MAIN. RETIRE48FEETOF 3 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WiTH RAILROAO COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 130 FEET OF 4 INCH POLY MAIN, RETIRE 130 FEET OF 3 INCH STEEL MAIN, ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200 ALL-MIX INSTALL 5 FEET OF 4 INCH STEEL MAIN. INSTALL 84 FEET OF 3 INCH POLY MAIN, ANO RETIRE 89 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISslON OF TEXAS RULE 8.209 All· MIX INSTALL 6 FEET OF 2 INCH STEEL MAIN AND RETIRE 6 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTAILL242 FEET OF 2 INCH POLY MAIN. RETIRE242 FEET OF 2 INCH STEEL MAIN, AND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCOROANCE WITH RAILROAD COMMISSIONOFH'XAS RULE 8,209 ALL-MIX INSTALL 126 FEET OF 2 INCH STEEL MAIN, 129 FEET OF 31NCH STEEL MAIN, 450 FEET OF 2 INCH POLY MAIN, RETIRE 576 FEET Of 2 lNCH STEEL MAIN, 129 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE W!TH RAILROAD COMMISSION OF TEXAS RUL~ 8,209 ALL-MIX INSTALL69FEET OF2 INCHPOLY MAIN, RETIRE69 FEET OF2 INCH STEEL MAIN, ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MiX INsTALL 36 FEET OF 4 INCi-i STEEL MAIN, RETIRE 36 FEET OF 4 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 138 FEET Of 2 INCH STEEL MAIN, RETIRE 138 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RU(.E 8,209 ALL-MIX INSTALL 12 FEET OF 3 INCH STEEL MAIN AND RETIRE 12 FEET OF 3 INCH STEEL MAIN JN ACCORDANCE WITH RA!LROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 56 FEET OF 3 INCH POLY MAIN AND RETIRE 5B FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of Tl'XJ\S RULE 8.209 ALL-MIX INST ALL 25 FEET OF 2 INCH STEEL MAIN, RETIRE 25 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 60 FEET OF 2 INCH POLY MAIN AND RETIRE 60 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 44 FEET OF 2 INCH POLY MAIN AND RETIRE 44 FEET Of 2 INCH STEEL MAJN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 ALL-MIX INST ALL 10 FEET OF 2 INCH STEEL MAIN ANO RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 157 FEET OF 4 INCH POLY MAIN, RETIRE 157 FEET OF4 INCH STEEL MAIN, AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX INSTALL 24 FEET OF 3 INCH STEEL MAIN AND RETIRE 24 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANC!O WITH RAILROAD
4 COMMISSION OF TEXAS RULE 8.209 ALL-MIX
20
11
156
159
10
29
62
53
42
47
113
26
63
INSTAILL 42 FEET OF 2 INCH STEEL MAIN, RETIRE 42 FEET Of 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAil.ROAD COMMISslON OF TEXAS RULE 8.209 INSTALL 64 FEET Of 3 INCH STEEL MAIN, RETIRE 64 FEET OF 3 INCH STEEL MAIN. AND 4 SERVICES IN ACCORDANCc WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST AILL 42 FEET OF 2 INCH STEEL MAIN, RETIRE 42 FEET Of 2 INCH STEEL MAJN. AND 1 SERVICE IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION o:i-: lE:XAS RUL.e 6.209 INST ALL 19 FEET OF 2 INCH STEEL MAIN, RETIRE 19 FEET OF 2 INCH STEEL AND 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 179 FEET OF 2 INCH POLY MAIN, RETIRE 179 FEET OF 2 INCH STEEL MAIN, AND 5 SERVIOcS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
INSTALL 117 FEET OF 2 INCH POLY MAIN, RETIRE 117 FEET Of 2 INCH STEEL MAIN, AND REPLACE 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMiSSION OF TEXAS RULE 8,209 INSTALL51 FEET OF2 INCHSTEEL, RETIRE 51 FEETOF2 INCH STEEL, ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RULE 8.209 INSTALL 45 FEcT OF 3 INCH STEEL MAIN AND RETIRE 45 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 209 FEET Of 2 INCH POLY MAIN AND RETIRc 200 FEET OF 2 INCH STl'EL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULi; 6,209
INSTALL 41 FEET OF 2 INCH STEEL MAIN, RETIRE 41 FEET OF 2 INCH STEEL MAIN, AND 1 RESIDENTIAIL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL52 FEET OF6 INCH STEEL MAIN. RETIRE52FEET OF6 INCH STEEL MAIN, ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
wrx Additions P:age32 of98
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
AlL·MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE. PLACED lN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVlCE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SY.SlEM INTEGRHY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVIS~ON SYSTEM lf.ffEGRITY MAY-2016
030 TEXAS DiVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM IMPROVEMENTS MAY,2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM. INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTcGRITY MAY-2016
030 TEXAS O!VISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTE;GRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY~2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM tNTEGRlTV MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1J COST
1281 030.28834 07 51'
1282 030_:28839 286 2S8
1283 030.28841 479 479
12.84 030,28842 585 585
1285 030.28843 38 38
1200 030.28844 26 28
1287 030.28845 46 46
12aa 030,2SB54 168 1BB
1289 030.28881 3,164 3,16"4
1290 030.28003 24 24
1291 030.28879 4,087 4,087
1292 030.2.8884 109 109
1293 030.28886 73 73
1294 030.28908 36 36
1295 030.29909 13 13
1296 030.28910 351 361
1297 030.28911 18 18
1298 030.28921 15 15
1299 030.28922 69 69
1300 030.28924 103 103
1301 030.28926 250 200
1302 030.28927 710 710
1303 030.28929 560 566
1304 030.28935 73 73
1305 030.28935 807 807
1300 030_28938 26 26
1307 030.28940 696 8$6
1308 030.28941 649 649
1309 030,28943 194 194
1310 030.28945 37 37
1311 030.289.fiO 363 363
1312 030.26955 338 338
1313 0:30.28953 239 239
1314 030.28966 23 23
1315 030.26007 55 55
ATMOS ENERGY CORPORATION, W~STTEXAS DIVISION INTERIM COST RECOVERY AND RA TE ADJUSTMENT REPORT
PROJfCT REPORT CV l016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
lNSTALL 174 FEETOF2 INCH POLY MAIN, RETIRE 1216 FEET OF 6 INCH STEEL, AND 10 SERVlCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL34ffFEETOF 4 INCH POLY MAIN, RETIRE 346FEETOF2 INCH STEEL MAIN AND 2 ASSOCIATED SERVlCES IN ACCORDANCE WITfl RAllRDAD COMMISSION OF TEXAS RULE 8.2.09 INSTALL 18 FEET OF 3 INCH AND646 FEET OF 2 INCH POLY MAIN, RETIRE 664 FEET OF2 INCH STEEL MAIN, AND 15SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALLB26 FEET OF 2 INCK POLY MAlN. RETIRE 723 FEET OF 3 INCH STEEL MAlN, AND 19 SERVICES IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RU!.E B.209 INST ALL 25 FEET OF 3 INCH POLY MAIN ANO RETIRE 25 FEET OF 3 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE. 8.209 INST ALL 27 FEET OF 2 INCH PDLV MAIN ANO RETIRE 27 FEET OF 3 INCH STEEL MAlN IN ACCORDANCE wm-1 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTA!.L 32 FEET OF 4 INCH STEEL MAIN AND RETIRE 32 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E B.209 INSTALL 206 FEET OF 4 INCH POLY MAIN AND 256 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RELOCATE 100 FEET OF 3 INCH AND 50 FEET OF 2 INCK STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5,736 FEET Of 2 INCH POLY MAIN, RETIRES,591 FEET OF 4 INCH ANDO INCH STEEL MAlN, AND 146 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 25 FEET OF 2 INCH POLY MAIN, RETIRE459 FEET OF 2 INCH AND 3 INCH STEEL MA~N. AND 1 SERVlCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 23 FEET OF 2 INCH POLY MAIN AND RETIRE 23 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 10 FEET OF 2 INCH STEEL MAlNAND RETIRE 10FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 70 FEET OF 2 INCH PD!. Y MAIN, RETIRE 70 FEET OF 2 INCH STEEL MAIN. AND 2 SERVICES IN ACCORDANCE WITH RAlLRDAD COMMISSION DFTEXAS RULE 8.209 RETIRE 106 FEET OF 2 INCH SlEEL MA1N IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTAL!.150 FEET OF 21NCH POLY MAlN, RETIRE 150 FEET OF 2 INCH STEEL MAlN, AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTA!.l. 33 FEET OF 2 INCH POLY MAIN, RETIRE 33 FEET OF 2 INCH STEEL MAIN, AND 2 SERV3CES IN ACCORDANCE WITH RAU.ROAD COMMISStON OF TEXAS RULE 8.209 INSTALL 24 FEET OF 3 INCH POLY MAIN AND RETIRE 24 FEET DF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL38" FEETDF 2 INCH POLY MAIN, RETIRE464 FEET OF 1.25 INCH AND 2 INCH STEEL MAIN, ANO 2 SERVICES IN ACCOROANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 INST ALL 1600 FEET OF 6 INCH POLY MAIN AND RETIRE 1600 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAlLRDAD COMMISSION OF TEXAS RULE 8.209
INSTALL 400 FEET OFB INCH POLY MAIN, INSTALL 121 FEET OF 2 INCH POLY MAIN, RETIRE 522 FEET OF 10 INCH, B INCH, 3 INCH, AND 2 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RU!.E 8.209 INSTALL95FEET OF2 INOliPDLY MAlNAND RETIRE95FEET DF2 INCH STEEL MAIN IN ACCORDANCE WITH RAllRDAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1167 FEET DF2 INCH, 3 INCH, AND 6 INCH POLY MAIN AND RETIRE 1167 FEET OF 3 INCH, 4 INCH, AND 8 INCH STEEL MAIN IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RLILE8.209 INSTALL 45 FEET OF 4 !NCH STEEL MAlN, RETIRE 45 FEET OF 4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITK RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL 1139 FEET OF 21NCH POLY MAIN AND RETIRE 973 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION O~ 'l'EXAS RUL~ 8_209 INSTALL658 FEET OF 4 INCH POLY MAIN. RETIRE668FEETOF 4 INCH STEEL MAIN. AND 15 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 694 FEET OF 2 INCH POLY MAIN AND RETIRE 694 FEET OF 2 INCH AND 3 INCH STEEL MAIN IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 INSTALLS FEETDF 3 INCH POLY MAlN AND 5 FEET OF 3 INCH STEEL MAI!>! IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 INSTALL 439 FEET OF 4 INCH POLY MAIN, 94 FEET OF 3 INCH STEEL MAIN AND RETIRE 439 FEET OF 6 INCH AND 94 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAlLRDAD COMMISSION OF TEXAS RULE 8.209 INSTALL 777FEETDF2 INCH POLY MAIN, RETIRE 777 FEET DF2 INCH STEEL MAIN, AND 17 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL238FEETOF2 INCKPDLY MAlNAND RETIRE23B FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RU!.E 8.209 INST ALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 11 FEETOF3 INCH POLY MAIN AND RETIRE 11 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAlLRDAD COMMISSION OF TEXAS RllLE 8.209
WJ>: Addltlr;Jn:;; PagC! 33 af98
CUSTOMERS llENEFITED
ALL-MIX
ALL- MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
Al.L-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-Ml)(
ALL-MIX
ALL· MIX
Al.l-MIX
ALL-MIX
DATE PLACED IN GAS PLANTIN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2.016
030 TEXAS D!VISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VISIDN SYSTEM INTEGRITY MAV-2.016
030 TEXAS D!VlSIDN SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRJTY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY OCTOBER y 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVIStON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OIVISIDN SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM l~'TEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM ~NTEGRITV MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
o:m TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSlDN SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1] cosr
1316 030.2B!le6 26 26
1317 030.28973 13 13
1318 030.28976 41 41
1319 030.28980 86 00
1320 030.28997 360 360
1321 030.29014 370 370
1322 030.29016 33 33
1323 030.29017 5,841 5,841
1324 030.29025 1,149 1,149
1325 030.29029 28 28
1326 030.29035 159 159
1327 030.29041 268 268
1328 030.29054 64 64
1329 030,29065 10 10
1330 030.29066 61 51
1331 030_29059 42 42
1aa2 030.2ll082 22 22
1333 030_29083 18 18
1334 030.29084 34 34
1336 030.29085 43 43
1336 o:m.2911e 19 19
1337 030.29119 44 44
1338 030.29148 62 62
1339 030.29151 579 579
1340 030.29159 135 135
1341 030.29171 1.394 1.394
1342 030.29173 63 83
1343 030.29174 312 312
1344 030.29175 580 680
1345 030.29178 94 94
1346 030.29185 290 2ll0
1347 030.29166 37 37
1348 030.29192 1,242 1,242
1349 030.29194 45 45
1350 030.29195 67 67
1351 030.29200 22 22
ATMOS ENERGY CORPORATION, WEST TfXAS DIVISION tNTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT Rf PORT Cl 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 25 FEET OF 2 INCH STEEL MAIN AND RETlRE 25 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD CDMMISSJON OF TEXAS RULE 8.209 REPU\CE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 163 FEETOF2 INCH POLY MAIN AND RETIRE 183 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 164 FEET OF 2 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RU!£ a,209
INSTAU.. 736 FEET OF 2 INCH POLY MAIN, RETIRE73B"FEETOF2 INCH STEEL MAIN, AND ASSOCIATED SERVICES IN ACCORDANCi:; WITH RAILROAD COMMJSSION OF TEXAS RULE B.209
lNSTALL680FEET OF2 INCH POLY MAIN, RET!RE680FEETOF 2 lNCH OF STEEL MAIN, MID 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMtSSION DF TEXAS RULE a.209 REMOVE IDLE SERVICE DUE TO LEAl<AGE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 15,942 FEET OF2 INCH POLY MAIN, RETIRE 16,935 FEET OF VARIOUS SIZES OF STEEL MAIN, AND 344 ASSOCIATED SERVICES IN ACCORDANCE WlTH RAILROAD COMMISSION Cf TEXAS RULE 8.209 INSTALL 1518 FEET OF 2 INCH POLY MAIN, RETIRE 19 FEET OF 2 INCH PVC MAIN, RETIRE 1503 FEET OF 2 INCH STEEL MAIN, AND 16 ASSOCIATED SERVICES IN ACCORDANCE WITI-l RAILROAD COMMISSION OF TEXAS :RlJLE 8.209 INSTALL 12 FEET OF 3 INCH POLY MAIN ANO RETIRE 12 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 290 FEET OF 4 INCH POLY MAIN AND RETIRE 290 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1:96 FEET OF2 INCH POLY MAIN, RETIRE 196 FEET OF2 INCH PVC MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMM!SSION OF TEXAS RULE 8.209 INSTALL 11 FEET OF 4 INCH STEEL MAIN, RETIRE 11 FEET OF4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 425 FEET OF 2 INCH POLY MAIN AND RETIRE 425 FEET OF 2 INCH ABS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 3 INCH STEEL MAIN AND RETIRE 20 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMJSBlON OF TEXAS RULE B.209 INSTALL 32 FEET OF 3 INCH STEEL MAIN, RET!RE 32 FEET OF 3 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 34 FEET OF 2 INCH POLY MAIN AND RETIRE 34 FEET OF 2 INCH ABS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.200 INSTALL 66 FEET Of 3 INCH STEEL MAIN AND RETIRE 66 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INST All 22 FEET OF 2 INCH POLY MAIN AND RETIRE 22 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 6.209 REPU\CE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 31 FEET OF 2 INCH POLY MAIN AND RETIRE 31 FEET OF 2 INOH ABS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE ONE SERVICE IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE 8.209 INST ALL 6 FEET OF 2 INCH POLY MAIN, RETIRE 6 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 767 FEET OF 4 INCH POLY MAIN, RETIRE597 FEET OF 3 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL4663 FEET OF2 INCH POLY MAIN, 1 SERVICE AND 1 METER STATION, RETIRE 4003 FEET OF 2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMISION OF TEXAS RULE 5.209 REPU\CE 1 SERVICE IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 6.209
INSTALL 620 FEET OF 2 INCH POLY MAIN, RETIRE 620 FEET Of 2 INCH STEEL MAIN, AND 17 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 671 FEET OF 2 INCH POLY MAIN, 671 FEET OF 4 JNCH POLY MAIN ANO RETIRE 671 FEET OF 3 INCH STEEL AND 1 ASSOCIATED SERVICE IN AaCORDANCEW!TH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 22 FEET OF 3 INCH POLY MAIN AND RETIRE 22 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 19 FEET OF2 INCfl STEEL MAIN, RETIRE 19FEETOF2 INCH STEEL MAIN AND 2 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALl.11 FEETOF6 INCH STEIOL MAIN AND RETIRE 11 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL5000 FEET OF 2 INCH POLY MAIN AND RETJRE 5000fEET OF 2 INCH OF STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET OF 2 INCH POLY MAIN AND RETIRE 6 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 60 FEET Of 2 INCH POLY MAIN ANO RETIRE 60 FEET OF 2 INCH STEEL MAIN ll>ll\CCOROANCEWITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL 10 FEET OF 4 INCH POLY MAIN AND RETIRE 10 FEET Of 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209
wnc Additions Page-34 of98
CUSTOMt;RS BENEFITED
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MlX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALl·MlX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
All-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PU\CEO IN GAS PLANT IN
LOCATION f:IURPOSE O~ PROJECT SERVICE
030 TEXAS DIVISION SVSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY- 2018
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER~ 2016 I
030 TEXAS DlVlSION SYSTIOM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRiTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DiVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201a
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST!1l COST
1352 030.29203 87 •7
1353 030.29207 29 29
1354 030,29209 54 54
13-55 030.292.10 35 35
1356 030.29211 633 633
1357 o::m.w212 63 63
1358 030.29215 7J 73
1359 030.29216 SS 55
1360 030.29217 25 25
1361 030.29216 170 170
1J62 030.29221 52 52
13B3 oao.29222 22 22
1364 000.29223 33 33
1365 030.29225 8.211 8,211
1300 030.29226 48 4B
1367 030.29227 2.477 2,477
1368 030.29228 27 27
1369 030.29229 48 48
1370 030.29:234 1.102 1,102
1371 030.29244 307 307
1372 030.29245 J,J03 3,303
1373 030.29248 26 28
1374 030.29249 21 21
1375 OJ0.29264 13 13
1376 030.29268 10 10
1377 030.29304 81 81
1378 030.29306 33 33
1379 030.29307 36 36
1380 030.29308 35 35
1381 030.29311 58 58
1362 030,29312 57 67
1383 030.29314 23 23
1364 030.29327 68 68
1385 030.29329 16 16
13"5 030.25'330 42 42
1387 030.29331 47 47
1368 030.29332 53 53
1369 030.29334 24 24
A.TMO.S ENERGY CORPORATION, WEST TEXAS DIVISION INURIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT RtPORT CT 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATl::O TO PUBLIC UsE IN CALENDAR YEAR 2016 (2)
INSTALL 14 FEET OF 4 INCH STEEL MAIN. RETIRE 14 FEET OF 4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WJTH RAlLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL21 FEET OF 2 INCH STEEL MAlN. RETIRE21 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE wm1 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL20 FEET OF2 INCH STEEL MAIN. RETIRE 20FEET0f 2 INCH STEEL MAIN, AND 1 SERVICE l'l ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUL!O 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 784 FEET OF6 INCHPOLY MAIN AND RETIRE 784 FEET OF 7 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 15 FEET OF 2 INCH POLY MAIN AND RETIRE 15 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 130 FEET OF 2 lNCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCH STEEL MAIN AND RETIRE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 17 FEET OF 2 INCH POLY MAIN, RETIRc 17 FEET OF 2 INCH STEcL MAlN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 10 FEET OF 2 INCH POLY MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAIUROAD COMMISSION Of TEXAS RULE B.209 . REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 10 FEET OF 2 INOH STEEL MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 30 FEET OF 2 INCH POLY MAIN AND RETIRE 30 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAIUROAD C:::OMMlSSION OF TEXAS RULE B.209 INSTALL 14,504 FEET OF2 INCH POLY MAIN, RETIRE 17,221 FEET OF 3 INCH, 4 INCH AND 6 INCH STEEL MAlN, AND 323 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 15 FEET OF 2 INCH STEEL MAIN, RETIRE 15 FEET OF2 INCH STEEL MAIN, AND 1 SERVICE IN ACCDRDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 270 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 29 FEET OF 2 INCH POLY MAIN AND RETIRE 29 FcET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSIDN OF TEXAS RULE B.209 INSTALL 5 FEET OF 2 INCK STEEL MAIN. RETIRE 5 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1014fEET OF 4 INCH POLY MAIN, RETIRE 1014 FEET OF 4 INCH STEEL MAIN AND 14 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RlJLE 6.209 INSTALL B76 FEET OF 2lr-ICH POLY MAIN. RETIRE 676 FEET OF 2 INCK STEEL MAIN AND 12 ASSOCIATED SERVICES IN ACCORDANCE WITH RAIUROAD COMMISSION OF TEXAS RULE 6,209
INSTALL 2490 FEET OF 2 INCH POLY MAIN, RETIRE 2590 FEET Of 2 INCH STEEL MAIN, AND 66 SERVICES IN ACCORDANCE WITH RAIUROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 27 FEET OF 2 INCH POLY MAIN AND RETIRE 27 FEET OF 2 INCfl STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL 1 O FEET OF 2 INCH PDLY MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITK RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 250 FEET OF 2 INCH POLY MAIN AND RETIRE 250 FEET OF 2 INCH ABS MAIN 1N ACCORDA."IJCE W!TH RAILROAD COMMISSION OF TEXAS RULc 8.209 INST ALL 6 FEET OF 2 INCH POLY MAIN AND RETIRE 6 FcET OF 2 INCH ABS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 101 FEET OF 1.25 INCH POLY MAIN AND RETIRE 101 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 16 FEET Of 2 INCH POLY MAIN AND RETIRE 16FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 16 FEcT OF 2 INCH POLY MAlN AND RETIRE 16 FEET OF 2 INCH STcEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 25 FEET OF 2 INCH STEEL MAIN AND RETIRE 25 FcET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 52 FEET OF 4 INCH STEEL MAIN, RETIRE 52 FEET OF 4 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 45 FEET OF 4 INCH STEEL MAIN. RETIRE 45 FEET OF 4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL O FEET Of 2 INCH POLY MAIN. AND RETIRE 8 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.205 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCH STEEL MA!N AND RETIRE 5 FEET OF 2 1NCH STEEL MAIN JN ACCORDANCE WiTH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 5 FEET OF 2 INCH STEEL MAlN AND RETIRc 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE W!TH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 17 FEETOF4 INCH POLY MAIN, RETIRE 17 FEET4 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 12 FEET OF 2 INCH POLY MAIN AND RETIRE 12 FEET OF 2 INCH ASS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2og
WTXAddltlons IJ;j!ge .sis of98
CUSTOMERS BENEFITED
ALL-MIX
ALL· MIX
ALL-MIX
ALL- MIX
ALL· MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
AlL·MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL· MIX
ALL-MIX
DATE PLACED IN GAS PLANTIN
LOCATION PURPOSE OF PROJECT SERVICE
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-:m1S
030 TEXAS DMSJON SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTcGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
0'30 TEXAS D!VISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYST!'M INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSlEM INTEGRHY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2010
LINE NO. PROJECT NUMBER COSTj1)
1390 030.29358 39
1391 030.29365 484
1392 030.29366 11
1393 030.29369 131
1394 030.29370 21
1395 030.29376 291
1396 030.29380 48
1397 030,29381 63
1398 030.29382 1169)
1399 030.29363 82
1400 030.29388 66
1401 030.29391 1
1402 030.29394 13)
1403 030,29:396 1
1404 030.29420 30
1405 030.29421 65
1406 030.29427 27
1407 030.29429 36
1408 030.29430 17
1409 030.29432 7
1410 030.29433 6
1411 030.29434 14
1412 030.29435 22
1413 030.29436 47
1414 030.29443 44
1415 030.29453 118)
1416 030.29454 63
1417 030.29464 26
1418 030.29470 21
1419 030.29471 88
1420 030.29511 j57
1421 030.29519 20
1422 030.29520 1249)
1423 030,29638 39
1424 030.29544 49
1425 030.29545 56
1420 a:m.29546 27
1427 030.29548 69
1428 030.29550 6
A.TMO.S ENERGY CORPORATION, WEsT TEXAS :QIVISION INT£RlM COS.T RECOVERY AND RA T:E ADJUSTMENT RE:POR.l'
PROJECT REPORT CV 2016
ALLOCATED DESCRIPTLON OF COMPLETED PROJECTS DEDICATED TO CUSTOMf::RS COSl' PUBUC USE IN CALENDAR YEAR 2016 {2)
INSTALL 7 FEET OF 4 INCH POLY MAIN ANO RETIRE 7 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
39 COMMISSION OF TEXAS RULE 8.209 INSTALL 735FEET OF 4 INCfl POLY MAIN AND RETIRE 735 FEET OF 6 INOfl STEEL MAIN IN ACCORDANCE WITH RAILROAD
464 COMMISSION OF TEXAS RULE 8.209 INSTALL 18 FEET OF 2 INCH STEEL MAIN AND RETIRE 18 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITK RAILROAD
11 COMMISSION OF TEXAS RULE B.209 INSTALL 24 FEET OF 2 INCH STEEL MAIN, RETIRE 24 FEET OF 2 INCH ST!'EL MAIN, AND 1 SERVICE IN ACCORDANCE W!TH
'"' RAILROAD COMMISSION OF TEXAS RULE a.209 INSTALL25 FEET OF 2 INCH STEEL MAIN AND RETIRE 25 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
21 COMMISSION OF TEXAS RULE 8.209 INSTALL 110FEET OF8 INCH STEEL MAIN AND RETIRE 110FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
291 COMMISSION OF TEXAS RULE 8.209 INSTALL 1 FEET OF 2 INCH POLY MAIN AND RETIRE 7 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
48 COMMISSION OF TEXAS RULE a.209 INSTALL 17 FEET OF 4 INCH STEEL MAIN, RETIRE 17 FEET OF4 INCH STEEL MAIN, AND 1 SERV;CE IN ACCORDANCE WITH
63 RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
11691 COMMISSION OF TEXAS RULE 8.209 INSTALL 120 FEET OF 2 INCH POLY MAIN, RETIRE 120 FEET OF 2 INCfl STEEL MAIN, AND 5 SERVICES IN ACCORDANCE WITH
82 RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
00 COMMISSION OF TEXAS RULE 6.209 INSTALL 132 FEET OF 21NCH POLY MAIN, 429 FEET OF 1.25 INCH POLY MAIN, RETIRE 5B1 FEET OF 2 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITI-l RAILROAD COMMISSION OF
1 TEXAS RULE 8.209 INSTALL 117 FEET OF 3 INCH POLY MAIN, RETIRE 117 FEET OF 3 INCli STEEL MAIN,AND 3 SERVICES IN ACCORDANCE WITH
131 RAILROAD COMMISSION OF TEXAS RULE 6.209 INST ALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE o FEET OF 2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
1 OF TEXAS RULE 8.200
INSTALL 900 FEET OF 2 INCH POLY MAIN. RETIRE 1000 FEET OF 2 INCH ABS ANO 1 ASSOCIATED SERVICE IN ACCORDANCE WITH
30 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 26FEETOF2 INCH POLY MAIN AND RETIRE 26FEETOF2 INCH PVC IN ACCORDANCE WiTH RAILROAD COMMISSION OF
65 TEXAS RULE 8.209 INSTALL 42 FEET OF 4 INCH STEEL MAIN AND RETIRE 42 FEET OF STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF
27 TEXAS RULE 6.209 INSTALL 17fEET OF2 INCHSTEEL MAIN, RETIRE 17 FEET OF 2 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH
36 RAILROAD COMMISSION OF TEXAS RULE 8,209 INSTALL 18 FEET OF 3 INCH STEEL MAIN AND RETIRE 1:8 FEET Of 3 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION Of
17 TEXAS RULE 8.209 INSTALL 20 FEETOF 3 INCH POLY MAIN AND RETIRE 24 FEETOF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
7 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 s!ORVICE IN ACCORDANCE W!TH RAILROAD
6 COMMISSION OF TEXAS RULE 8,209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
14 COMMISSION OF TEXAS RULE 8.209 INSTALL 44 FEET OF 2 INCH STEEL MAIN AND RETIRE 44 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD
22 COMMISSION OF TEXAS RULE 8.209 INSTALL20 FEET OF 2 INC!l POLY MAIN ANDRETIRE20 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
47 COMMISSION OF TEXAS RULE 8.209 RELOCATE 310 FEET OF 4 INCH POLY MAIN IN ACCORDANCE
44 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCfl POLY MAIN AND RETIRE 5 FEET OF 2 INCH ABS IN ACCORDANCE WITH RAILROAD COMMISSION OF
118) TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE 5 FEET OF 2 INCH STEEL MAlN IN ACCORPANC!O WITH RAILROAD
63 COMMISSION OFTEXASRUL!; 8.209 INSTALL 60 FEET OF 2. INCH POLY MAIN AND RETIRE 80 FEET OF 2 INCH ABS IN ACCORDANCE WITH RAILROAD COMMISSION Of
26 TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
21 COMMISSION OF TEXAS RULE B.200 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
88 COMMISSION OF TEXAS RULE 8.209 INSTALL 223 FEET OF 2 INCH POLY MAIN, RETIRE 223 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
157) RAILROAD COMMlsSIDN OF TEXAS RULE B.209 INSTALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE 5 FEET OF 2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMJSSION
20 OF TEXAS RULE 8.209
(249)
39
49
56
27
69
6
INSTALL BO FEET OF 6 INCH POLY MAIN AND RETIRE 80 FEET OF 6 INCH STEEL MAIN IN AcCOR!lANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 34 FEET OF 2 INCH STEEL MAIN AND RETIRE34FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRED 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 107 FEET OF 21NCH POLY MAIN AND RETIRE 107 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 600 FEET OF 2 INCH POLY MAIN AND RETIRE 500 FEET OF 2 INCH Aas MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 fNSTALL 35 FEETOF2 INCH STEEL MA.IN, RETIRE 35 FEET Of 2 lNCH STEEL MAIN, AND 1 SERVJCE IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 16 FEETOF2 INCH STEEL MAIN, RETIRE 16 FEErOF2 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
W0C Addition:S Page 36 of98
BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
AL!.-MlX
ALL- MIX
J\U.. MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL- MIX
ALL-MIX
All.-MIX
ALL-MIX
ALL· MIX
All-MIX
ALL-MIX
ALL· MIX
All-MIX
ALL-Ml)(
ALL· MIX
AL!.-MIX
ALL-MIX
ALl-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL· Mix
DATE PLACED IN GASP~NTIN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS OMS ION SVSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRflY MAY-2016
030 TEXAS DIVISION SYSTEM !NTEGRllY MAY-2016
030 TEXAS DIVISION SVSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS !JIV!SION SYSTEM INTEGRITY MAY-2010
030 TEXAS DIVISION SYSTEM INTEGRflY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SVSTIOM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROllEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION sYsTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT N.UMBER COST(1l
1429 030.29554 591
1430 030.29556 2,087
1431 030.29:563 1,260
1432 030.29564 151
1433 030.29565 24
1434 030.29567 646
1435 030.29566 4,437
1436 030.29569 21
1437 030.29570 27
1468 030.29571 38
1439 030.29586 26
1440 030.29596 260
1441 0'30.29597 14
1442 OB0.29598 171
1443 030.29599 (4)
1444 030.29600 (0
1445 030.29612 299
1446 030.29616 "" 14~7 030.29619 52
1448 030.29620 " 1449 030.29621 m
1450 03.0.29622 31
1451 030.;29636 (11
1452 030.20036 31
1453 030.29640 73
1454 030.20042 45
1455 030.29643 565
1456 030.29644 229
1457 030.29645 37
1458 030.29650 45
1459 030.29661 142
1460 030,2966:3 2
1461 030.29565 " 1462 030.200£6 14
1463 030.2:9667 25
1464 030.29674 123
1465 030.29676 979
ATMOS ENERGY CORPORATION, WEST TE:itAS OIVISIO~ INTERIM (:OST RECOVERY ANO RATE ADJUSTMENT REPORT
PROJECT REPORT Ci 2016
ALLOCATED DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO COST PUBLIC USE IN CALENDAR YEAR 2016 (21
INSTALL 700 FEIOTOF 4 INCH POLY MAIN ANDRETIRE700FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
591 COMMISSION OF TEXAS RULE 6.209 INST ALL 3135 FEET OF 2 INCH POLY AND 2 INCH STEEL MAIN AND RETIRE 3135 FEET OF 2 INCH STEEL AND 2 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
2,067 8,209-
INST AL 2230 FEET OF 2 INCH POLY MAJN, RETIRE 2230 FEET OF 2 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE
1,260 wm1 RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
{5) COMMISSION OF TEXAS RULE 8.209 INSTALL 12fEETOF2 INCH POLY MAINANDRETIRI' 12FE;ETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
24 COMMISSION OF TEXAS RULE 8.209 lNSTALL5295 FEET OF21NCH POLY MAIN ANDRETIRE5295 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD
646 COMMISSION OF TEXAS RULE 6.206
INSTALL 10,130FEETOF2 INCHPOLY MAIN, 1020 FEET OF 4 INCH POLY MAIN, RETIRE9064 FEET OF 2 INCH STEEL MAIN, 1046 FEET OF 3 INCH STEEL MAIN, 1020 FEET OF 3 INCH STEEL MAIN AND 210 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD
4,437 COMMISSION OF TEXAS RULE 8.209 INSTAll 20 FEET OF 2 !NCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
21 COMMfSSION OF TEXAS RULE 8.209 INSTALL 8 FEET OF 2 INCH POLY MAIN, RETIRE 8 FEET OF 2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH RAILROAD
7J COMMISSION OF TEXAS RULE 8.209 INST ALL 51 FEET Of 3 INC!l POLY MAIN, RETIRE 51 FEET OF 3 INCH STEEi. MAIN. AND 1 SERVICE IN ACCORDANCE WITH
38 RAILROAD COMMISSION OF Tl'XAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
26 COMMISSION OFTEXAS:RlJLE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
280 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
14 COMMISSION OF TEXAS RULE B.209 RETIRE 610 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH
171 RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL280 FEET OF 4 !NCH POLY MAIN AND RETIRE280 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(4) COMMISSION OF TEXAS RULE 6.206 INSTALL 35 FEET OF 4 INCH POLY MAIN, RETIRE35FEETOF 4 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH
(0] RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 2 INCH PLOY MAIN IN ACCORDANCE WITH RAILROAD
299 COMMISSION OF TEXAS RULE B.209 RETl:RE 215 FEE:T OF 3 INCH SlEEL M~N IN ACCORDANCE WITH
86 RAJLROAD COMMISSION OF TEXAS RULE 6.200 INSTALL 57 FEET OF 1.25 INCH POLY MAIN, RETIRE SO FEET OF2 INCH STEEL MAIN, AND 1 COMMERCIAL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
52 6.:209
INSTALL 9 FEET OF 2 INCH POLY MAIN AND RETIRE 9 FEET OF 2 INCH ABS IN ACCORDANCE WITH RAILROAD COMMISSION OF
9 TEXAS RULE 6.209 INSTALL 56 FEET OF 2 INCH POLY MAIN, RETIRE 58 FEET OF 2 INCH STEEL MAIN, AND 1 SERVJCE IN ACCORDANCE WITH
{3} RAILROAD COMMISSlON OF TEXAS RULE 6.209 INST ALL 17 FEET OF 2 INCH STEEL MAIN AND RETIRE 17 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
31 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVlCE IN ACCORDANCE WITH RAILROAD
f1 I COMMISSION OF TEXAS RULE 8.209 INSTALL 21 FEET OF 2 INCH STEEL MAIN AND RETIRE 21 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WlTH RA!LROAD
31 COMMISSION OF TEXAS RULE 8.209 INSTALL 29 fE;ET OF 2 INCH STEEL MAIN, RETIRE 29 FEET OF 2 INCH STEEL MAlN, AND 1 SERVICE IN ACCORDANCE Willi
73 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 140 FEETOF2 INCH POLY MAIN AND RETIRE 140 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAJLROAD
45 COMMISSION OF TEXAS RULE 8.206 INSTALL 31 FEET OF 2 INCH POLY MAIN AND RETIRE; 31 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
565 COMMISSION OF TEXAS RULE a.209 lNSTALL 29 FEET OF 2 INCH POLY MAIN AND RETIRE 29 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RJ\ILRDAD
229 COMMISSION OF TEXAS RULE 8.209 INSTALL 37 FEET OF 4 INCH POLY MAIN AND RETIRE 37 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
37 COMMISSION OF TEXAS RULE 8.209 INSTALL 139FEETOF2 INCH POLY MAIN, RETIRE 139FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
45 COMMISSION OF TEXAS RULE 8.209
INST ALL 323 FEET OF 2 INCH POLY MAIN, RETIRE 323 fEET OF 2 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE
142 WITH RAILROAO COMMISSION OF TEXAS RULE 8.209 INSTALL 132FEET OF2 INCH POlY MAIN. 429 FEET OF 1.25 INCH POLY MAIN. RETIRE 561 FEET OF 2 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF
2 TEXAS RULE 8.209 INSTALL 169 FEET OF 2 INCH STEEL MAJN, RETIRE 169 FEET OF 2 INCH STEEL MAIN, /\ND 2 SERVICES IN ACCORDANCE WlTH
8 RAILROAD COMMISSION OF TEXAS RULE B.209
14
25
123
979
INSTALL 40 FEET OF 3 INCH STEEL MAIN AND RETIRE 40 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200 INSTALL 138 FEET OF 3 INCH POLY MAIN, RETIRE 138 FEET OD3 INCH STEEi. MAIN. AND 2 SERVICllS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 725 FEET DF2 INCfl POLY MAIN, RETIRE 725 FEET OF 2 INCH STEEL MAIN, AND 20 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTAll 305 FEET OF6 INCH POLY MAIN AND RETIRE 305FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209
wntAddftfon!i Page37of9B
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALl-MIX
ALL-MIX
ALL-MIX
/\LL-MIX
All-MIX
ALL.MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
Al.L-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-M!X
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201S
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS Dtv!SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS OlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DJVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
o:m TEXAS DIVISION sYSTllM INTEGRITY SllPTEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBE:R - .2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SVSTEM INTEGRITY MAY·201B
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAYR2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSlEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
LINE NO. PROJECT NUMBER COSTj1]
1466 030.29690 443
1467 030.29691 -351
146S 030.29692 191]
1469 030.29695 14
1470 o:ao.296'96 47
1471 O!l0.29697 17
1472 O!l0.29710 !6l
1473 030.29711 2
1474 030.29712 11
1475 030.2!!715 19
1476 030.29717 21
1477 030.2W1S 13
1478 030.29720 82
1479 030.29721 1
1480 030.29722 19
1481 030.29723 • 1482 000.29729 121
1483 030.29730 249
1484 030.29731 27.407
1485 030.29738 34
1466 030.29741 17
1487 030.29751 105
1488 030.29704 37
1489 O!l0.29755 89
1490 0'30,29756 44
1491 000.29757 4
1492 030.29780 (6
1493 030,29782 (674
1494 030.29788 111]
1495 030.29790 11
1496 030,29793 (227]
1497 030.29794 222
1496 030.29796 1.622
1499 030.29797 458
1500 030.29799 27
1501 030.29803 (6531
1502 030.29810 275
1500 000.29821 13031
1504 OJ0.29B25 43
ATMOS ENERGY CO.RPOM110N, WEST TEXAS DIVISION INTERIM COST RECOVERY AND RATE AOJUSTMENT REPORT
PROJECT REPORT Cl 2016
ALLOCATED DESCR•PTION OF COMPLETED PROJECTS DEDICATED TO COST PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 200 FEET OF 2 INCH POLY MAIN, RETIRE 295 FEET OF 2 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH
443 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 140FEET OF2 INCfl POLY MAIN, RETIRE 140FEETOF 1 INCH STEEL MAIN, AND 3 SERVICES IN ACCORDANCE WITH
351 RAILROAD COMMISSION OF TEXAS RULE 8-2Jl9 :REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
!91] COMMlSSION OF TEXAS RULE B.209 INST ALL 19 FEET OF 2 INCH POLY MAIN ANO RETIRE 19 FEET OF 2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
14 OF TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE 5 FEET OF 2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
47 OF TEXAS RULE 8_209 INSTALL 10 FEET OF 2 INCH POLY MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
17 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
(6] COMMISSION OF TEXAS RULE 8.209 INSTALL 19 FEET OF 3 INCH STEEL MAlN AND RETIRE 19 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
2 COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 2 INCH STEEL MAIN, RETIRE20 FEET OF2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
11 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 15 FEET OF 2 INCH POLY MAIN AND RETIRE 15 FEET OF 2 INCH ABS IN ACCORDANCE WITH RAILROAD COMMISSION OF
19 TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WtTH RAILROAO
21 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WrTH RAILROAD
13 COMMISSION OF TEXAS RUl.E 8,209
INST ALL 12 FEET Of 3 INCH STEEL MAIN AND RETIRE 12 FEET OF 3 INCH STEEL AND 1 ASSOCIATED SERVlCE IN ACCORDANCE
82 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
1 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
19 COMMISSION OF TEXAS RULE 8.209 INSTALL 120 FEET OF 2 INCH POLY MAIN AND RETIRE 120 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
6 COMMISSIONOFTEXASRULE8.209 INSTALL 7 FEET OF 3 INCH POLY MAIN AND RETIRE 7 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
{21 COMMISSION OF TEXAS RULE 8.209 INSTALL 1281 FEET OF 2 INCH POLY MAIN A'lD RETIRE 1281 FEET OF 2 INCH STEEL MAIN AND 8 REPLACE SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
249 8.209
INSTALL 6119 FEET OF 2 INCH, 7058 FEET OF 4 INCH POLY MAIN, REGULATOR STATION COMPONENTS, 58 SERVICES AND RETIRE 6952 FEET OF 2 INCH, 3225 FEET OF 3 INCH, 4713 FEET OF 8 INCrl STEEL MAIN AND 65 ASSOCIATED SERVICES IN ACCORDANCE
27,407 WITH RAILROAD COMMISION OF TEXAS RULE 8.209 RETIRE ONE SERVICE IN ACCORDANCE WITH RAILRAOD
34 COMMISSION OF TEXAS RULE 8.209 INSTALL 40 FEET OF 2 INCH POLY MAIN AND RETIRE 40 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
17 OF TEXAS RULE 8.209 INST ALL 497FEET OF 2 INCH POLY MAIN, RETIRE 497 FEET OF 2 INCH STEEL MAIN AND 13 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
105 S.209 INSTAlL322fEET DF2 INCH POLY MAIN, RETIRE 322 FEET OF2 INCH STEEL MAIN, ANO 1 SERVICE IN ACCORDANCE WITH
37 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 671 FEET CF 2 INCH POLY MAIN AND RETIRE 671 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
89 COMMISSION OF TEXAS :RULE 8.209 RETIRE 920 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH
44 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 14 FEET Of 3 INCH POLY MAIN AND RETIRE 14 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
4 COMMISSION OF TEXAS RULE 8.209 INSTALL 35 FEET OF 2 INCH POLY MAIN AND RETIRE 35 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
161 OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
(6741 COMMISSION Of TEXAS RULE 8.209 INSTALL 7 FEET OF 2 INCH sTEEL MAIN. RETIRE 7 FEET OF 2 INCH STEEL MAIN. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD
(11] COMMISSION OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD
11 COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
(227) COMMISSION OF TEXAS RULE 6.209 REPLACE 4 AND 6 METER MANIFOLDS IN ACCORDANCE WIT!1
222 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2680FEET OF2 INCH POLY MAIN, RETIRE 2680 FEET OF 2 INCH STEEL MAIN, AND 9a SERVICES IN ACCORDANCE WITH
1,622 RAILROAD COMMISSION OF TEXAS RULE 8-209 INSTALL 5 FEET OF 2 INCH POLY MAIN, RETIRE 5 FEET OF 2 INCH PVC MAIN. AND 1 SERVICE IN ACCORDANCE WITH RAILROAD
458 COMMISSION OF TEXAS RULE S.209 INSTALL250 FEET OF 2 INCH POLY MAIN. RETIRE250 FE!OTOF 2 INCH STEEL MAIN. AND 6 SERVICES IN ACCORDANCE WITH
27 RAIL.ROAD COMMISS!ON OF TEXAS RULE 8,209 INSTALL 11 FEETOF2 INCHPOLY MAIN AND RETIRE 11 FE.ET OF2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
16531 OF TEXAS RULE 8.209 INSTALL 16 FEET OF 2 INCH STEEL MAIN ANO 2 SERVlCES AND RETIRE: 16 FE.ET OJ=" 2 INCH S1EEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
275 B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
po31 COMMISSION OFTEXAS RULE 8,209 INSTALL40 FEET OF2 INCH POLY MAIN AND RETIRE40 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
43 COMMISSION OF TEXAS RULE 8.209
WTXAcldition-s P~ge 38 of98
CUSTOMERS BENEFITED
ALL- MIX
ALL-MIX
ALL-MIX
ALL· MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
/\LL-MIX
ALL-MIX
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
Alla MIX
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALLMMIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL· MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE l'..,.CED IN GAS PLANTIN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS OIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEX/IS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2010
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MllY ·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OC''rOBER ~ 201-6
O!lO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DJ VISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -201B
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
LINE NO. PROJECT NUMBER COST(11
1006 030.29826 58
1506 030.29830 55
1507 0J0.298J1 (9)
1508 0'30.29632 22
1509 030.29839 183
1510 000.29841 (3
1511 030,29842 (3)
1512 OJ0.29843 828
1513 030.29844 267
1514 030.29845 59
1515 030_:29640 16
1516 030.29848 10
1517 o:m.29849 10
1518 o:m.29a50 !SJ
1519 03-0.29852 m
1520 030.29854 102
1521 030.29855 16
1522 030.29870 4
1523 030.29871 16
1524 030.29872 (71'
1525 030.29875 (21
1526 030.29877 (3)
1527 030.29879 19
1528 030.29882 20
1529 030.29885 2,204
1530 030.:29887 109
1531 030.29869 17
1532 030.29890 rs
1533 OJ0.29892 53
15J4 030.29895 22
153:5 000.29906 379
15J6 030.29911 26
1537 030.29912 27
1538 030.29913 111
1539 030.29925 (10
1540 030.:29927 15
1541 o.so.29ooa 13
ATMOS ENERGY CORPO!lJ\TION, WESTTl'XAS DIVISION INTERIM COST ReCOVERY A.ND RATE ADJUSTMENT REPOA.T
PROJECT R~PORT CY 2016
ALLOCATEO OESCR.IPTION OF COMPLETE.0 l>ROJECTS DEDICATE:.IJ l"O CUSTOMERS COST PUBLIC USE IN CALENDAR VEAR 2016 (2)
RETIRE 108 FEET OF 2 INCH PVC MAIN IN ACCORDANCE WITH 58 RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL JJ FEET OF 4 INCH STEEL MAIN, RETIRE 33 FEET OF 4 !NCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
55 RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 7 FEET OF 2 INCH STEEL MAIN AND RETIRE 7 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(9) COMMISSION OF TEXAS RULE 8.209 INSTALL 44 FEET OF 4 INCH STEEL MAIN, RETIRE 26 FEET DF 4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE Wl'flj
22 RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD
183 COMMISSION OF TEXAS RULE 8.209 INSTALL 8 FEET OF 3 INCH STEEL MAIN ANO RETIRE 8 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(3] COMMISSION OF TEXAS RULE B.209 INSTALL 202 FEET OF21NCH POLY MAIN, RETIRE 154 FEET OF2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH
IJ] RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTAU. 886 FEET OF BINCH POLY MAIN, INSTALL 976FEET OF 4 INCH POLY MAIN AND RETIRE 1862 FEET OF 6 INCH STEEL MAININ ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
828 B.;209 INSTALL 70 FEET OF 2 ANO 4 INCH MAIN AND RETIRE 145 FEET OF 3 lNCH STEEL MAIN JN ACCORDANCE WITH RAILROAD
267 COMMISSION OF TEXAS RULE 8.209 INSTALL 28 FEET OF 2 INCH STEEL MAIN, RETIRE 28 FEET OF 2 INCi-i STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
59 RAILROAD COMMISSION OF TEXAS RULE 8.209 INST All 50 FEET OF 3 INCH POLY MAIN AND RETIRE 50 FEET Of 4 INCH STEEL MAIN IN ACCORDANCE WITH RAlLROAD
16 COMMISSION OF TEXAS RULE S.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
10 COMMISSION OF TEXAS RULE 8.209 REPlACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
10 COMMISSION OF TEXAS RULE 8.209 REPlACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
(9) COMMISSION OF TEXAS RULE 8.209 INST ALL 15 FEET OF 2 INCH POLY MAIN AND RETIRE 15 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
[7) COMMISSION OF TEXAS RULE 8.209 INSTAll95FEETOF 4 INCH POLY MAIN, RETIRE 95 FEET DF4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
102 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 15 FEET OF 2 INCH STEEL MAIN AND RETIRE 15 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
16 COMMISSION PF TEXAS RULE 8.209 INSTALL 25 FEET OF 2 INCH STEEL MAIN AND RETIRE 25 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD
4 COMMISSION OF TEXAS RULE 8.209 INSTALL 713 FEET OF 1.25 INCH POLY MAIN AND RETIRE 713 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
16 GOMMISSIONOF'rEXAS RULE B.209 INSTALL5 FEET OF J INCH STEEL MAIN AND RETIRE 5FEET OF3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
'771 COMMISSION OF TEXAS RULE 8.209 INSTALL 40 FEET OF 2 INCH POLY MAIN AND RETIRE 40 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
(2) OF TEXAS RULE 8.209 INSTALl40FEET OF2 INCH POLY MAIN AND RETIRE40FEET DF2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
(31 OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
19 COMMISSION OF TEXAS RULE 6.209 INSTALL 51 FEET OF 2 INCH POLY MAIN, RETIRE 48 FEET OF 2 INCH STEEL MAIN AND 2 ASSOCIATED SERV!Cf:;S IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
20 a.209 INSTALL6378 FEET OF 2 INCH POLY MAIN, 394 FEET OF 4 INCH POLY MAIN, RETIRE 6378 FEET OF 2 INCH STEEL MAIN, 394 FEET OF 4 INCH STEEL MAIN AND 7J ASSOCIATED SERVICES IN ACCORDANCE WJTH RAILROAD COMMISSION OF TEXAS RULE
2,2.04 6.209
109
17
(5
"" 22
379
26
27
111
(10
15
13
REPLACE 1 SERVICE IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL4 FEET OF 2 INCH STEEL MAIN, 4 FEET OF4 INCH STEEL MAIN, RETIRE 4 FEET OF 2 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE a.209 INSTALL 40 FEET OF 2 INCH POLY MAIN AND RETIRE 40 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 195 FEET OF 2 INCH Pol Y MAIN AND RETIRE 195 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION PF TEXAS RULE 8.209 INSTALL222FEETOF2 INCHPOlY MAIN, RETIRE 219FEET OF2 INCH STEEL MAIN AND 3 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL22 FEET OF2 INCH STEEL MAIN, RETIRE22FEET OF2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL29 FEET OF2lNCH STEEL MAIN, RETIRE29 Fl=ET OF2 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE; WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST All 20 FEET OF 2 INCH STEEL MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 INSTALL 22 FEETOF2 INCH POLY MAIN. RETIRE 22FE;ETOF2 INCH STEEL MAlN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 49 FEET OF 3 INCH POLY MAIN AND RETIRE 49 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX AddltlQDS Page39af98
BENEFITED
ALL-MIX
ALL· MIX
All-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
AL!.-MIX
ALL-MIX
All-MIX
AU.-MIX
All-MIX
AU.-MIX
AU.-MIX
ALL· MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL.- MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
AlL-MiX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACE:D IN GAS PLANT IN
LOCATION PUl::i:POSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DJVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY.2016
030 TEXAS DIVISION SYSTEM INTEGRflY MAY-2016
OJOTEXAS DIVISION SYSTEM INTEGRITY MAY .201a
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM lNTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DiVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISJON SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY.2.016
OJO TEXAS DIVJSION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
OJO TEXAS DIVISION SYSTEM INTEGRITY M/\Y-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV·2016
030 TEXAS OIVIStON SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE No. PROJECT NUMB.ER COST(1)
1542 030_2.9930 227
1543 030.29931 78
1544 030.29933 131
1545 o:m.29936 (6)
1546 030.29942 36,339
1547 030.29943 1,205
1548 030.29957 0
1549 030.29958 140
1550 030.29969 [41
1551 030.29970 ••
1552 030.29974 24,733
1553 030.29979 1,304
1554 030.29980 B
1555 030.29961 19
1556 030,29984 127
1557 0'30.29986 1,708
1556 030.30001 38
1659 030.30005 3.104
1560 030.30014 179
1561 030.30035 52
1562 030.30039 14
1563 030.30041 291
1564 030.30044 47
1565 030.30045 48
1566 030.30046 15
1567 03-0.30052 10
1568 030.30053 25
1569 030.30055 14
1570 030.30062 43
1571 030.30066 15
1572 030.30067 111
1573 030.30070 100
1574 030.30071 [8)
1575 030.30075 33
1576 030.30078 60
1577 030.30079 125
1578 030.300!34 40
ATMOS ENERGY CORPORA HON, WEST TEXAS DIVISION INTERIM COST RECOVERY ANP MTE ADJUSTMENT R£PORT
PROJECT REPORT CV 2016
Al-LOCATED DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO cos-r PUBLIC USE IN CALENDAR YEAR 2016 (21
INSTALL 278 FEET OF21NCH POLY MAIN. RETIRE 230 FEET OF 2 INCH STEEL MAIN, AND 48 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
227 B.209 INSTALL 55 FEET OF 2 INCH POLY MAIN AND RETIRE 55 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
78 COMMISSION OF TEXAS RULE 8.209 INSTALL 1071 FEET OF2 INCH POLY MAIN AND RETIRE 1071 FEET OF 3 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD
m COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 4 INCH POLY MAIN AND RETIRE 20 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(8} COMMISSION OF TEXAS RULE 8.209 INSTALL 11,900 FEETOF2 INCH, 4650FEETOF 4 INCH POLY MAIN. 01 ASSOCIATED SERVICES AND RETIRE 8572 FEET OF 2 INCH, 423 FEET OF 3 INCH, 38 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
36,339 8,209 INSTALL 1992 FEET OF 2 INCH POLY MAIN, RETIRE 1992 FEET OF 2 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
1,205 B.209 INSTALL 10 FEET OF 2 INCH STEEL MAIN, RETIRE 10 FEET OF 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH
0 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL365 FEET OF 2 INCH POLY MAIN, RE11RE365 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAil.ROAD
140 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
[4) COMMISSION OF TEXAS RULE B.209 INSTALL 236 FEET OF 2 INCH POLY, RETIRE 87 FEET OF 2 INCH STEEL, RETlRE OBSOLETE REGULATOR STATION IN ACCORDANCE WH'H R,ajlROAO COMMISSION Of TEXAS RULE
91 B.209 ll>ISTALL 1045 FEET OF 21NCH AND 10500FEET OF 1.25 INCH l'OLYMAIN AND RETIRE 1045 FEET OF 3 INCH POLY MAIN AND 11063 FEET OF 3 INCH PVC MAIN AND REPLACE 60 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
24,733 6.209 INST ALL 58 FEET OF 1.25 INCH POLY MAIN Al<D RETIRE 56 FEET OF 2 INCH STEEL MAIN IN ACCORDA'lCE WITH RAILROAD
1,304 COMMISSION OF TEXAS RUL~ 8.209 INSTALL 11 FEET OF 3 INCH STEEL MAIN, RETIRE 11 FEETOF3 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITf-1
8 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 17 FEET OF 2 INCH POLY MAIN AND RETIRE 17 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
19 COMMISSION OF TEXAS RULE 8.209 INSTALL45 FEET OF2 INCH STEEL MAIN, RE11RE45FEETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
127 COMMISSION OF TEXAS RULE 8.209 RELOCATE FACILITIES: INST ALL 215 FEET Of 6 INCH AND 260 FEET OF B INCH STEEL MAIN. RETIRE215 FEET OF 6 INCH AND 260 FEET OF B INCH STEEL MAIN DUE TO PUSLIC. IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
1,708 B.209 REPLACE REGULATOR STATION AT 1-27 AND URSULINE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
38 B.209 REPLACE 70 METERS IN ACCORDANCE WITH RAILROAD
3.104 COMMISSION OF TEXAS RULE B.209 REBUILD REGULATOR STATION IN ACCORDANCE WITH RAILROAD
179 COMMISSION Of TEXAS RULE B.209
INSTALL WELDOVER ON 2 INCH STEEL MAIN IN ACCORDANCE 52 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
14 OF TEXAS RULE B.209 INSTALL 256 FEET OF 2 INCH POLY MAIN ANO RETIRE 256 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
291 COMMISStON OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD
47 COMMISSION OF TEXAS RULE 8.209 INST ALL 80 FEET OF 2 INCH POLY MAIN AND RETIRE 60 FEET OF 2 INCH ASS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
48 OF TEXAS RULE 6.209 INSTALL 24 FEET OF 2 INCH l'OLYMAIN ANO RETIRE 24 FEETOF2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
15 OF TEXAS RULE B.209 INSTALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN fN ACCORDANCE WITH RAILROAD
10 COMMISSION OF TEXAS RULE 6.209 INSTALL 33 FEET Of 4 INCH POLY MAIN, RETIRE 33 FEET OF 4 INCH STEEL MAIN, AND 1 SERVICE IN ACCORDANCE WITH
25 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 19 FEET OF 2 INCH POLY MAIN AND RETIRE 19 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAil.ROAD
14 COMMISSION OF TEXAS RULE 8.209 INSTALLS? FEET OF 4 INCH POLY MAll>!AND RETIRE87FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAil.ROAD
43 COMMISSION OF TEXAS RULE 8.209 INST ALL A WELDOVER ON 3 INCH PIPE IN ACCORDANCE WITH
15 RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL ti FEET OF 2 INCH POLY MAIN ANDRETIRE6 FEETOF2 !NCH PVC tN ACCORDANCE WlTH R~LROAD COMMISSlON OF
111 TEXAS RULE 8.209 INSTALL ENCIRCLEMENT ON 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
100 8.209 INSTALL20FEET OF 4 INCH POLY MAIN AND RETIRE20 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
[B) COMMISSION OF TEXAS RULE 8,209
33
60
125
40
REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0,209 INSTALL 92B FEET OF 2 INCH POLY MAIN AND RETIRE 926 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 REPLAOE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTXAdc:IUions Page 40 of 98
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All.- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All.- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
All.- MIX
AU.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOS~ OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGR!lY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-201S
030 TEXAS DIVISION SYSTEM INTEGRtTY MAY-2016
030 TEXAS DIV!SJON SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY.2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXA.S DIVISION PUSLIC IMPROVEMENTS MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y OCTOSER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAs DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
o:ao TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY.2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAYu2016
030 Tt=XAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(t) COST
1579 030_30085 64 64
1680 030.30087 28 26
1561 030.30069 104 104
1582. 030.30090 90 90
1563 030.30091 150 150
1584 030.30092 135 135
1585 030.30094 38 36
1586 030.30097 345 345
1587 030.30105 99 99
1588 030.30115 56 56
1569 030.30116 69 69
1590 030.30117 160 160
1591 030.30118 394 394
1592 030.30119 94 94
1593 000.30120 47 47
1594 030.30121 49 49
1595 030.30122 16 16
1596 030.30123 46 46
1597 030.30124 16 16
1598 030.30125 14 14
1599 030.30127 191 191
1600 030.30128 53 53
1601 030.30131 74 74
1602 030.30132 171 171
1£03 030.30134 144 144
1604 030.30139 654 654
1605 030.30143 301 301
1606 030.30144 379 379
1607 030,30145 5; B3
1608 030.30146 040 240
1609 030.30147 225 225
1610 030.30148 291 291
1611 030.30150 ;03 303
1612 030.30151 637 637
1613 030.30152 451 451
1614 030.30154 465 485
ATMOS. ENERGY CORPOAATlON, WEST TEXAS DIVISION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
RETIRE 14 FEET OF 2 !NCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICI:;. IN ACCORDANCE W!TH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 175 FEET Of 2 INCH POLY MAIN. RETIRE 173 FEET Of 2 INCH STEEL MAIN, AND; RESIDENTIAL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 6.209 INSTALL 224 FEET OF 4 INCH POLY MAIN, RETIRE 224 FEET OF 4 INCH STEEL MAIN AND 4 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL65FEET OF2 INCH POLY MAIN, RETIRE 85 FEET OF2 INCH STEEL MAIN, AND 3 RESIDENTIAL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL20FEET DF2 INCH POLY MAIN, RETIRE 20 FEET OF2 !NCH STEEL MAIN, AND 2 RESIDENTIAL SERVICES IN ACCORDANCE WITH RPJLROAD COMMISS!ON OF TEXAS RULE 8.209 INSTALL 28 FEET OF 2 INCfi POLY MAIN, RETIRE 30 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL H84 FEEL OF 2 INCH POLY MAIN, RETIRE 1484 FEET OF 2 INCH STEEL MAIN, AND 16 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 263 FEET OF 2 INCH POLY MAIN ANO RETIRE 263 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL WELDOVER ON 8 INCH STEEL MAlN IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET OF 3 INCH STEEL MAIN AND RETIRE TWO 3 INCH DRESSER COUPLINGS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INST/\l.l 52 FEET OF .5 INCH POLY SERVICE LINE A. .. DRETIRE 52 FEET OF 1 INCH STEEL SERVICE LINE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 381 FEETOF2 INCH POLY MAIN AND RETIRE381 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 340 FEET OF 2 INCH POLY MAIN, RETIRE 340 FEET OF 2 INCH STEEL MAIN AND 3 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET Of 4 INCH STEEL MAIN AND RETIRE ONE 4 INCH DRESSER COUPLING IN ACCORDANCE WITH RA!LROAO COMMISSION OF TEXAS RULE B.209 RETIRE ONE SERVICE IN ACCORDANCE WITH AAILRAOD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 10 fEETOF 2 INCH STEEL MAIN. RETIRE 10 FEET OF2 INCH STEEL MAIN, AND 1 RESIOENTIAL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WfTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 14 FEETDF2 INCH POLY MAIN AND RETIRE 14 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 22 FEET OF 4 INCH POLY MAIN AND RETIRE 30 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 30 FEET OF 2 INCH PDLY MAIN AND RETIRE 30 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALLS FEET OF2 INCH STEEL MAIN AND RETIRE 6 FEETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL WELDOVER ON 8 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 195 FEET OF 1.25 INCH POLY MAIN AND RETIRE 195 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL376 FEET OF 2 INCH POLY MAIN, 378 FEET OF 4 INCH OF POLY MAIN, RETIRE410 FEET OF 4 INCHSTEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RULE 8.209 REPLACE DEEPWELL IN AMARILLO TO IMPROVE CATHODIC PROTECTION !N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL5S7 FEET OF 1.25 INCHPOLY MAIN, RETIRE567 FEET OF 2 INCH STEEL MAIN. AND 5 RESIDENTl/11. SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL500 FEET Of 2 INCH POLY MAIN AND RETIRE 500 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELl IN PALISADES TO IMPROVE CATHODIC PROTECTION IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209
·REPLACE DEEPWELL IN TANGLEWOOD TO IMPROVE CJ\THOOIC PROTECTION IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN AMARILLO TO IMPROVE CAlliODIC PROTECTION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 REPLACE DEEPWELL IN AMARILLO TO IMPROVE CATHODIC PROTECTION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELl IN MULESHOE TO IMPROVE CATHODIC PROTECTION IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELl IN MULESHOE: TO IMPROVE CATHODIC PROlECTlON IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl~ a.209 REPLACE OEEPWELL IN MULESHOE TO IMPROVE CATHODIC PROTECTION IN ACCOORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
W1X Additions Page41or9.s
CUSTOMERS BENEFITED
All-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All· MIX
ALL-MIX
ALL-MIX
/11.L-MIX
All-MIX
All- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL- MlX
ALL- MIX
ALL- MIX
Al.L-MIX
A\.L-MIX
ALL-MIX
ALL· MIX
ALl-MIX
ALL- MIX
ALL-MIX
PATE PLACEO IN GAS PLANT IN
LOCATLON PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OJO TEXAS OIV[S!ON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISlON SYSTEM INTEGRITY MAY-201a
030 TEXAS DIVISION SYSTEM INTEGRITY MJ\Y-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MJ\Y-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM lNTEGRITY MAY-2016
030 TEXAS DIVJS!ON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
!IBO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
! OSO TEXAS OIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MJ\Y-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST(1l
1615 030.30155 262
1616 030.30156 363
1617 030.30157 357
1616 030.30158 299
1619 030.30159 341
1620 030.30161 340
1621 030.30162 2,666
1622 030.30163 2,767
1623 030.3016~ 3,152
1624 030.30165 3,136
1625 030.30166 2,787
1526 030.30167 2,702
1627 030.30180 47
1628 030.30189 68
1629 030.30191 76
1630 030.30193 171
1631 030.30203 55
1632 030.30209 99
1633 030.30210 78
1634 030.30212 77
1635 030.30213 163
1S36 030.30215 12a
1637 030.30230 185
1638 030.30231 5
1639 030.30234 111
1840 030,302:S6 34
1641 030.30237 136
16"42 OJ0.30243 71
1643 030.30245 75
1644 030.30250 273
1645 030.30251 904
1646 0'30.30254 100
1647 030.30255 3.368
1648 030.30259 19
1649 030.30260 238
1650 030.30263 69
ALLOCATED COST
262
363
357
299
341
340
2,656
2.767
3,152
3,136
2.787
2,702
47
68
76
171
55
99
78
77
163
126
1•5
ATMOS ENERGY CORPORATION, W£5T TEXAS DIVISION INTERIM COST RECOVERY ANO RATE A!>JUSTMENT REPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO cusroMERs PUBLIC USE IN CALENDAR YEAR 2016 (2) BENEFITED
REPLACE DEEPWELL IN LUBBOCK TO IMPROVE CATHODIC PROTECTION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX REPLACE DEEPWELL IN LUBJ!OCK TD IMPROVE CATHODIC PROTECTION IN ACCORDANCE WITH RAILROAD COMMISSION DF TEXAS RULE 6.209 ALL-MIX REPLACE DEEPWELL IN LUBBOCK TO IMPROVE CATHODIC PROTECTION IN ACCORDANCE WITf-1 RAILROAD COMMISSION OF TEXAS RULE 8,209 ALL-MIX REPLACE DEEPWEll IN LUBBOCK TO IMPROVE CATHODIC PROTECTION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX REPLACE DEEPWELL IN LUBBOCK TO IMPROVE CATHODIC PROTECTION lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX REPLACE DEEPWEll IN LUBBOCK TO IMPROVE CATHODIC PROTECTION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2iJ9 ALL-MIX REPLACE DEEPWEU. IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2019 ALL· MIX REPLACE DEEPWEU. IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL· MIX REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.20:9 AU.-MIX REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX INSTALL 10 FEET OF 2 INCH STEEL MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX INSTALL 17 FEET OF 2 INCH STEEL MAIN, RETIRE 17 FEET OF 2 INCH STEEL MAIN. AND 2 RESIDENTIAL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RIJLE 8.209 ALL-MIX INSTALL 109 FEET OF 1.25 INCH POLY MAIN AND RETIRE 109FEET OF 2 INCH STEEL MAIN ~N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALl.·MIX INSTALL 13 FEET OF 2 INCH STEEL MAlN, RETIRE 13 FEET OF2 INCH STEEL MAIN, AND 2 RESlDENT!Al SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RULE B.209 ALL-MIX REPl.ACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 ALL-MIX
INSTALL 10 FEET OF 2 INCH STEEL MAIN, RETIRE 10 FEET OF 2 INCi-! STEEL MAIN, AND 1 RESiDENTIAl. SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX RELOCATE FACILITIES. INSTALL 220 FEET OF 4 INCH POLY MAIN AND RETIRE 220 FEET OF 4 INCH POLY MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISS(ON OF TEXAS RULE 8.209 ALL-MIX INSTALL 17FEET OF 2 INCH STEEL MAIN AND RETIRE 17 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 326 FE!OT OF 2 INCH POLY MAIN, RETIRED 326 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITl-i RAILROAD COMISSION OF TEXAS RULE 8.209 ALL-MIX lNSTALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE 5 FEET OF 2 lNCH PVC MAIN IN ACCORDANCE WJTH RAILROAD COMMISSION
5 OF TEXAS RULE 6.209 ALL-MIX
111
34
136
71
75
273
904
100
3,366
1B
238
89
INSTALL 633 FEET DF 2 INCH POLY MAIN, RETIRE 633 FEET DF 2 INCH STEEL MAIN AND 7 ASSOCIATED SERVICES IN ACCORDANCE wm-l RAILROAD GOMMlSSION OF TEXAS RULE 8.209
INST ALL 25 FEET OF 3 INCH POLY MAIN, RETIRE 25 FEET OF 3 INCH STEEL MAIN, AND REPLACE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 32 FEET OF 2 INCH STEEL MAlN. RETIRE TWD 2 INCH DRESSER COUPLINGS, AND 1 RESIDENTIAL SERVICE IN ACCORDANCE WJTH RAILROAD COMMISSION OF TEXAS RUU:; 8.209 INSTALL 90 FEET OF 2 INCH POLY MAIN AND RETIRE 90 FEET OF 2 INCH ABS MAIN IN ACCOROANCEWITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INST ALL 50 FEET OF 2 INCH POLY MAIN. RETIRE 50 FEET OF 3 INCH STEEL MAIN, AND 1 RESIDENTIAL SERVICE IN ACCORDANCE WIT1--I RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 370FEET OF2 INCH POLY MAIN .RETIRE 370FEET OF2 INCH STEEL MAIN AND 9 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMM!SSION OF lEXAS RULE 8.209
INSTALL 250 fEET OF 2 INCH AND 150 FEET OF 4 INCH STEEL MAIN, RETIRE 250 FEET OF O INCH AND 150 FEET DF 4 INCH STEEL MAIN. AND 6 RESIDENTIAL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION DF TEXAS RULE 6.209 INSTALL 12 FEET OF 2 INCH STEEL MAIN AND RETIRE 12 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 4 2 INCH SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B .. 209 INSTALL 6 FEET OF 2 INCH STEEL MAIN AND RETIRE 6 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE METER AND REGULATOR STATION COMPONENTS IN LUBBOCK IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B .. 209
INSTALL 20 FEET OF 2 INCH POLY MAIN, RETIRE 20 FEET OF 2 INCH STEEL MAIN, AND 1 RESIDENTIAL SERVICE IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209
WTX A.ddttions Pag-e42-cf98
ALL-MIX
ALL-MIX
ALI.- MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
DATE PLACou '" GASPLANT!N
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAs DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGmTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VlSfON SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION PUBLlC IMPROVEMENTS MAY-2016
030 TE:;XAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRHY MAY-2016
030 TE)(AS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST{\)
1651 030.302.68 257
1652 030.30270 121
1653 030.30271 139
1654 030,30272 153
1650 030.30273 11B)
1656 030.30275 13
1657 030.30276 32
1656 030.3-0277 100
1659 030.30278 232
1660 030.30279 416
1661 03-0.30285 4
1662 030.30289 519
1663 030.30291 59
1664 030.30292 63
1665 030.30296 617
1666 030.30297 5
1667 030.30300 1,233
1668 030.30301 1,228
1B69 030,30306 78
1070 030.30307 123
1671 030.30308 53
1672 030,30309 271
1673 030.30312 525
1674 030.30330 139
1675 030.30331 95
1676 030.30332 93
1677 030.3-0333 215
1678 030,30334 685
1679 030.30336 3
1650 030.30337 161
1681 03-0.30343 92
1682 03-0.30346 (42)
1683 03-0.30347 40
1664 030.30350 21
1ea5 030.30352 23
1686 030.30356 25
1687 030.30365 333
1886 0$0.303198 550
1689 030.30367 697
1690 030.30374 5
ALLOCATED COST
257
121
139
153
[18)
13
32
100
232
•1•
ATMOS ENERGY CORPORATION, WEST TEXAS OIV~ION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2015 (2) BENEFITED
INSTALL2a4 FEET DF2 INCH POLY MAIN. 342 FEET OF 3 INCH POLY MAIN AND RETIRE 284 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAl\.F<OAD COMMISSION OF TEXAS RULE a.209 All-MIX
INSTALL 31 FEET OF 2 INCH POLY MAIN. RETIRE 31 FEET OF 2 INCH STEEL MAJN, AND 1 RESIDENTIAL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION TO TEXAS RULE 8.209 ALL-MIX RETIRE 342 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE B.209 All-MIX INSTAlL 5 FE;ET OF 3 INCH STEEL MAIN AND RETIRE o FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION TO TEXAS RULE 6.209 All-MIX INSTAll 137 FEET OF2 INCH POLY MAIN AND RETIRE 137 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 104 FEET OF 4 INCH POLY MAIN AND RETlRE 104 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WlTH RAILROAD COMMISS[ON OF TEXAS RULE 8.209 ALL- MIX
INSTALL 394 FEET OF2 INCH POLY MAIN, RETIRE 394 FEET OF2 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All· MIX INSTALL o FEET OF 2 INCH STEEL MAIN AND RETIRE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 All-MIX INT ALL 9 FEET OF 6 INCH STEEL MAIN AND RETIRE ONE 6 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RULE 6.209" AL!.-MI)( INST ALL 37 FEET OF 2 INCH STEol MAIN AND RETIRE FiVE 2 INCH DRESSER COUPUNGS IN ACCORDANCE WlTH RAiLROAD COMMISSION OF TEXAS RULE 8.209 ALL-MtK INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE
4 WffH RAILROAD COMMISION RULE OF TEXAS RULE 6.209 ALL-MIX INSTALL 75(} FEET OF 2 INCH POLY MAIN AND RETIRE 750 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD
519 COMMISSION OF TEXAS RULE 8.209 INSTALL 15FEET OF2 INCH POLY MAIN AND RETIRE 15 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
59 COMMISSlONOFTEXAS RULE 8.209 INSTALLS FEETOF2 INCH STEEL MAIN AND RETIRE 5FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
63 COMMISSION OF TEXAS RULE 6.209 REBUILD REGULATOR STATJON IN ACCORDANCE WITH RAILROAD
617 COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE
5 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD OBSOLETE REGUIATOR STATION IN ACCORDANCE
1,233 WITH RAILROAD COMMISSION OF TEXAS RULE S.209 REBUILD OBSOLETE REGUIATOR STATION IN ACCORDANCE
1,226 WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 11.25 INCH STEEL SERVICE IN ACCORDANCE WITH
78 RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 RESIDENTIAL SERVICE IN ACCORDANCE WITH
123 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 9 FEET OF 2 INCH STEEL MAlN AND RETIRE 9 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
53 COMMISSION OF TEXAS RULE 8.209 INSTALL 60 FEET OF 3 INCH STEEL MAIN AND RETIRE 60 FEET OF 4 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD
271 COMMISSION OF TEXAS RULE 8.209 INSTALL 1065 FEET OF 2 INCH POLY MAIN AND 32 FEET OF .75 INCH PLY MAIN, RETIRED 1085 FEET OF 2 INCH STEEL MAIN AND 32 FEET OF 1 lNCH STEAL MAlN IN ACCORDANCE WITK RAil.ROAD
525 COMMISSION OF TEXAS RULE 8.209 REPIACE 2 RESIDENTIAL SERVICES IN ACCORDANCE WITH
139 RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE METER AND REGULATOR ST ATIDN COMPONENTS AT FIRST BAPTlST CHURCH IN FRIONA IN ACCORDANCE WITH
95 RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE METER AND REGULATOR STATION COMPONENTS AT 601 MURPHY IN PAMPA IN ACCORDANCE WITH RAl!.ROAD
93 COMMISSION OF TEXAS RULE 6.209 INSTALL 15 FEET OF 4 INCH STEEL MAIN AND RETIRE TWO 4 INCH DRESSER COUPLINGS IN ACCORDANCE WITH RAILROAD
215 COMMISSION Of TEXAS RULE B.209 REBUILD REGU!ATOR STATION !N ACCORDANCE WITH RAILROAD
685 COMMISSION OF TEXAS RULE 8.209 RETIRED REGULATOR STATION AND 168 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Cf TEXAS
3 RULE8.209
161
92
1421
40
21
23
25
333
550
697
5
INSTALL 159 FEET OF 4 !NCH POLY MAIN, RETIRE 159 FEET OF 3 INCH STEEL MAIN, AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL230 FEET OF 2 INCH POLYMAlN ANDRETIRE230 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Cf TEXAS RULE 8.209 REBUILD REGULATOR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPIACE 1 RESIDENTIAL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL20Ff;ET OF2 INCH POLY MAIN AND RETIRE 20fEET OF2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 RESIDENTIAL SERVICE IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 70FEET Of 3 INCH STEEL MAIN. RETIRE 70FEETOF3 INCH STEEL MAIN ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 51 FEET OF 2 INCH POLY MAIN AND RETIRE 51 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
REBUllO CPR STATION AND PLUG VALVE DUE IN ACCORPANC~ WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 5 FEET OF 3 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WIXAddJUon5 P:age 43 cf98
All-Ml)(
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-Ml)(
All-MIX
ALL-MIX
ALL-M~
Ai.L-MIX
ALL-Ml)(
ALL-MIX
ALL-Ml)(
ALL-MlX
All-MIX
All-MIX
ALL-Ml)(
ALL-MIX
jlJ_l-M!X
ALL-MIX
ALL-MIX
ALL-MIX
ALL"MIX
ALL- MIX
ALL-M~
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
DATE .!-"LACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM INToGRITY MAY-2016
030 TEXAS DiVJstoN SYSTEM INTEGRiTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY"2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OW TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM IMPROVEMENTS OCTOBER -2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER-2016
03-0 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER -2016
030 TEXAS DIVISION SYSTEM IMPROVEMoNTS MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY~2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUM!IER COST{1]
1691 030.30378 1,219
1002 030,30380: 39
1693 030.30386 55
1694 030.30368 (17)
1695 030.30392 (28)
1696 030.30393 235
1597 030.30404 77
1696 030.30405 195
1699 030.30406 60
1700 030.30409 229
1701 030.30417 53
1702 030.30416 59
1703 030.30422 19
1704 030.30423 25
1705 030.30424 0
1706 030.30427 20
1707 030.30433 (71)
1708 030.30434 52
1709 030.30437 17
1710 030.30439 495
1711 030.30442 21
1712 030.30444 103
1713 030.30446 20
1714 o30.ao44a 68
1710 030.30449 26
1716 030.30455 463
1717 030.30456 287
171EI 030.30452 9
1719 030.30463 51
1720 030.30475 16
1721 030.30476 4
1722 030.30477 16
1723 030.30479 903
1724 030.30481 22
1725 030.30488 115
ATMOS ENERGY CORPORATION, WEST TEXAS OIVJSION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CV 2016
ALLOCATED DESCRiPTlmJ OF COll!'IPlETED PROJECTS DEDICATED TO CUSTOMERS COST PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 3700 FEEL OF 2 INCH POLY MAIN AND RETIRE 9230 FEET OF 2 INCH ABS MAIN IN ACCORDANCE W!TH RAILROAD
1,219 COMMISSION TD TEXAS RULE 8.209 INSTALL 14 FEET OF 2 INCH POLY MAIN AND RETIRE 14 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
39 COMMISSION OF TEXAS RULE B.209
RETIRE REGULATOR STATION AT 1 MARK DAVIS IN ACCORDANCE 55 WITH RAILROAD COMMISSION Of TEXAS RULE B.209
INSTALL 316 FEET DF2 INCH POLY MAIN, RETIRE 316FEET DF2 INCH STEEL MAlN, AND 10 RESIDENTIAL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
(17) 8.209 INSTALL 170 FEET OF2 INCH POLY MAIN, RETIRE 170 FEET OF2 INCH STEEL MAIN, A~D 3 RESIDENTIAL SERVlCES IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE
[28) 6.209 INSTAll 5 FEET OF 4 INCH POLY MAlN AND RETIRE ONE 4 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD
235 COMMISSION OF TEXAS RULE B.209 RETIRE 7340 FEET OF 2 INCH ABS MAIN IN ACCORDANCE; WITH
77 RAILROAD COMMISSION Of TEXAS RULE 6.209 INSTALL 240 FEET OF 2 INCH POLY MAIN, RETIRE 240 FEET OF 2 INCH STEEL MAIN AND 7 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
195 6.209 INSTALL 405 FEET OF 2 INCH POLY MAIN AND SERVICE, RETIRE 388 FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAlLROAD
50 COMMISSION OF TEXAS RULE 8.209 INSTALL 412 FEETDF 2 INCH POLY MAlN AND 14SERVICES, RETIRE 427 FEET OF 2 INCH STEEL IN ACCORDANCE WITH
229 RAILROAD COMMISSION Of TEXAS RULE 6.209 INSTALL 24 FEET OF 2 INCH STEEL MAIN AND RETIRE THREE 2 INCH DRESSER COUPLINGS IN ACCORDANCE WITH RAILROAD
53 COMMISSION OF TEXAS RULE 8.209
INSTALL 207 FEET OF J INCH STEEL AND 2 INCH POLY MAIN AND RETIRE 207 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH
59 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL66FEETOF2 INCHPDLY MAIN, RETIRE66 FEET OF2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF
19 TEXAS RULE 6.209 REPLACE METER AND REGULATOR STATION COMPONENTS IN LUBBOCK IN ACCORDANCE WITH RAllRDAD COMMISSION OF
25 TEXAS RULE 8.209 RETIRE275FEET OF 4 INCH POLY MAlN DUE TD PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION
O TO TEXAS RULE 8.209 INSTALL 8 FEET OF 2 INCH STEEL MAIN AND RETIRE 8 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
20 COMMISSION OF TEXAS RULE 8.2.09 INSTALL 466 FEET Of 2 INCH POLY MAIN AND 6 SERVICES, RETIRE 486 FEET OF 2 INCH STEEL IN ACCORDANCE WITH
(71) RAlLROAD COMMISSION OF TEXAS RULE B.209 JNSTALL 5 FEET OF 2 INCH STEEL, RETIRE 5 FEET Of 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS
52 RULEB.209 REPLACE 1 RESIDENTIAL SERVICE IN ACCORDANCE WITH
17 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL WELDOVER ON 4 INCH DRESSER IN ACCORDANCE WITH
495 RAii.ROAD COMMISSION DF TEXAS RULE 8.209 INSTALL 350 FEET OF 2 INCH PDLY MAIN AND 10 SERVICES, RETIRE 350 FEET OF 2 INCH STEEL IN ACCORDANCE WITH
21 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL B FEET OF 2 INCH STEEL MAIN AND RETIRE8 FEET OF 2 INCH STEEL MNN IN ACCORDANCE WITH RAILROAD
103 COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 2 INCH POLY MAIN AND SERVICE, RETIRE 20 FEET OF STEEL MAIN IN ACCORDANCE WITH RAILROAD
20 COMMISSION OF TEXAS RULE B.209
INSTAL!. 5 FEET Of 2 INCH STEEL MAIN. RETIRE o FEET OF 2 INCH STEEL MAIN. AND 1 RESIDENTIAL SERVICE IN ACCORDANCE
68 WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 38 FEET OF 2 INCH POLY MAIN AND RETIRE 38 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
26 COMMISSION OF TEXAS RULE 6.209 INSTAll 440 OF 2 INCH AND 3 INCH POLY MAIN. RETIRE 440 FEET OF 4 INCH STEEL MAIN, AND 4 COMMERCIAL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
463 H.209
INSTALL 515 FEET OF2 INCH POLY MAIN, RETIRE 515 FEET OF 3 INCH STEEL MAIN, AND 16 SERVICES IN ACCORDANCE WITH
287 RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 217 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH
9 RAILROAD COMMISSION OF TEXAS RULE 0.209 REPLACE METER AND REGULATOR STATION COMPONENTS AT GRACE CLINIC IN LUBBOCK IN ACCORDANCE WITH RAILROAD
51 COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE, RETIRE 1 SERVICE IN ACCORDANCE WITH
16 RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 76 FEETOF2 INCH POLY MAIN AND SERVICE. RETIRE 76 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
4 COMMISSION OF TEXAS RULE 8.209
18
903
22
115
INST ALL 398 FEET OF 2 INCH POLY MAIN. RETIRE 395 FEET OF 2 INCH STEEL MAIN AND 1 ASSOCIATED SERVlCE IN ACCORDANCE WITH RAILROAD COMMtSSION OF TEXAS RULE 8.2.09 INSTALL441 FEET OF 4 INCH POLY MAIN, RETIRE 441 FEET OF 3 lNCH STEEL MAIN AND 13 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDAMCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST All 376 FEET OF 2 INCH POLY MAIN ANO METER AND REGULATOR STATION COMPONENTS, RETIRE 376 FEET Of 2 INCH STEEL MA~N AND 2 ASSOCIATED SERVICES IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209
WTXAddnions Piil,ge 44 of98
BENEFITED
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
Al.L- MIX
ALL· MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All- MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL· MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All- MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GASPLANTIN
LOCAT(ON PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVJSION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRllY MAY-2015
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MA.Y-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-:2010
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVIStON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY OCTOBER - 2016
LINE NO. PROJECHdUMBER COST(1)
1726 030.30489 1,066
1727 030.30485 15
1728 030.J0505 1a
1729 030.30507 12.146
1730 OJ0.30515 33
1731 030.30521 5
1732 030.30529 24
1733 030.305'32 5
1734 030.30533 54
1735 030.30535 14
1736 030.30536 58
1737 030.30538 11
1738 030.30539 21
1739 030.30540 9
1740 030,30541 38
1741 030.30543 53
1742 030.30547 148
1743 o:m.3o555 387
1744 03-0.30557 16
1745 030.30571 38
1746 030.30572 32
1747 030.30573 54
1748 030.30591 33
1749 030.30593 13
1750 030.30598 20
1751 030.30597 245
1752 030.30598 37
1753 030.30599 215
1754 030_30600 7
1755 030,30613 23
1756 030.30616 43
1757 030,30622 29
1758 030.30623 23
1759 030.30624 19
1760 030.30627 3a
1761 030.30628 55
1752 0'30.30630 BB
1763 000.30632 38
ALLOCATED COST
1,066
15
18
12,146
33
ATMOS ENERGV CORPORA110N, WEST TEXAS Dl'l/l.SION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR io1a (2) BENEFITED
INSTALL3300 FEET OF 2 INCH POLY MAIN. RETIRE 3300 FEET OF 3 INCH PVC MAIN, AND REPLACE 20 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 1 SERVICE, RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL~ MIX INST ALL 147FEET OF 2 INCH POLY MAlN AND SERVICE, RETIRE 147 FEl'ff OF 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 14, 7"9 FEET OF 2 INCH AND 4 INCH POLY MAINS, RETIRE 15,742 FEET OF VARIOUS SIZES OF STEEL MAIN. AND 281 ASSOCIATED SIORVICES IN ACCORDANCE WITH RAil-ROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 1 SERVICE ANO RETIRE 1 SERVlCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD
5 COMMISSION OF TEXAS RULE 8.209 ALL-MIX .REPLACE 1 SERVICElNACCORDANCEWITH RAilROAD
24 COMMISSION OF TEXAS :RULE B.209 ALL- MIX REPLACE 1 SERVICIO IN ACCORDANCE WITH RAILROAD
5 COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 19 FEET OF 4 INCH POLY MAIN AND RETIRE 19 FEET OF 4 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD
54 COMMISSION RULE OF TEXAS RULE B.209 ALL-MIX INSTALL 5 FEET OF .75 INCH POLY MAIN AND SERVICE, RETIRE 5 FEET OF 1 INCH STEEL IN ACCORDANCE WITH RAlLROAD
14 COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 386 FEET OF 2 INCi-I POLY MAIN AND RETIRE 152 FEET OF 2 INCfl STEEL MAIN IN ACCORDANCE WITH RAILROAD
58 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST All 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE
11 WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 9 FEET OF 3 INCH STEEL MAIN, RETIRE 9 FEET OF 3 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS
21 RULE8.209 ALL-MIX INSTALL_ FEET OF. 75 POLY MAIN AND SERVICE, RETIRE_ FEET OF 1 INCH STEEL IN ACCORDANCE WITH RAILROAD
9 COMMISSION OF TEXAs RULE B.208 ALL-MIX INSTALL 52 FEET OF 4 INCH POLY MAIN AND RETIRE 52 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH
38 RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX
INSTALL 138 FEET OF >INCH POLY MAlN. RETIRE!l 1S8fEET OF 1 114 INCH POLY MAIN AND 2 INCH STEEL IN ACCORDANCE WITH
53 RAILROAD COMMISSION OF TEXAS RULE B.2QQ ALL-MIX INSTALL 98 FEET OF 4 INCH POLY MAIN AND 29 FEET OF 2 INCH POLY MAIN, RETIRE 98 FEET OF 4 INCH OF S1EEL MAlN AND 29 FEET OF 2 INCH STEEL MAlN, AND lWO SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
148 8.209 ALL- MIX RETIRE 1 INCH SERVICE IN ACCORDANCE WITH RAILROAD
387 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 10 FEET OF 2 INCH POLY PIPE AND RETIRE 1 O FEET OF 2 INCH sTEEL PIPE AND ONE SERVICE IN ACCORDANCE WITH
16 RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 12 FEET OF 3 INCH POLY MAIN AND RETIRE 12 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
38 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 128 FEET OF 2 INCH POLY MAIN, RETIRE 128 FEET OF 2 INCH STEEL MAIN AND 3 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
32 8.209 ALL-MIX INSTALL 185 FEET OF 2 INCH POLY MAIN, RETIRE 185 FEET OF 2 INCH STEEL MAlN AND 7 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
54 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
33 COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD
13 COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 SERVICE IN ACCORDANCE WITH RAlLROAD
20 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 1534 FEET OF 2INCH POLY MAlN. RETIRE 1534 FEET OF 2 STEEL MAIN IN ACCORDANCE WfTH RAILROAD COMMISSION OF
245 TEXAS RULE 8.209 ALL-MIX INSTALL 16 FEET OF2 INCH STEEL, RETIRE 168 FEET OF 21NCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS
37 RULES.209 ALL- MIX INSTALL 1307 FEET OF 21i'lCH POLY MAIN. RETIRE 1122 FEET OF 2 INCH STEEL MAIN AND 13 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
215 8.209 ALL-MIX INSTALL 1 SERVICE, RETIRE 1 SERVICE lN ACCORDANCE WITH
7 RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 13 FEET OF 3 INCH POLY MAIN AND RETIRE 13 FEET OF 3 INCH OF STEEL MAIN IN ACCORDANCE WITH RAILROAD
23 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 39 FEET OF 2 INCH POLY MAIN AND RETIRE 39 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE Willi RAILROAD
43 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 24 FEET OF 2 INCH POLY MAIN AND RETIRE 24 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
29 COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 11 FEET OF 4 INCH STEEL MAIN, RETIRE 11 FEETOF4 INCH :STEEL IN ACCORDANCE WITH RAILROAD COMMISSION Of
23 TEXAS RULE 8.209 ALL-MIX INSTALL B FEET OF 4 INCH POLY MAIN AND RETIRE B FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
19 COMMISSION OF TEXAS :RULE B.209 ALL-MIX INSTALL 30 FEET OF2 INCH POLY MAIN AND RETIRE 30 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
38 COMMISSION OF TEXAS RULE 8.209 All-MIX
INSTALL 41 FEET Of 2 INCH STEEL MAIN AND RETIRE 41 FEET OF DF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH
55 RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX REPLACE METER AND REGULATOR STATION COMPONENTS AT SUNSET CHURCH IN LUBBOCK IN ACCORDANCE WITH RAILROAD
88 COMMISSION OF TEXAS RULE 8-209 ALL-MIX INSTALL 6 FEET OF 2 INCH POLY MAIN ANO RETIRE 6 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD
38 COMMISSION OF TEXAS RULE B.209 ALL-MIX
WTX Additiom: Page45 of98
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS D!VISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRJTY MAY-2016
030 TEXAS DJVIS!ON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!V;SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISiON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION sYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201'!
030 TEXAS OIVlSION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVIS,ON SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VISION SYSTEM INTEGRITY OCTOBER - ;2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST(1)
1764 030.30633 79
1765 030.30634 32
1766 030.30637 909
1767 030.30642 23
1768 030.30043 79
1769 030,30644 37
1770 OJ0.30050 10
1771 030.30062 3,987
1772 030.30666 31
1773 030.30667 132
1774 030.30671 93
1775 030.30689 18
1776 030.30690 14
1777 030.30691 28
1778 030.30692 25
177• 030,30693 40
1780 030.30695 122
1761 030.30096 130
1782. 030.30697 24
1783 030.3-0698 48
1784 030.30699 955
1765 030.30706 213
1786 030.30708 1,138
1767 030.30719 21
1788 030.30720 30
1789 030.30721 8
1790 030.30722 25
1791 030.30723 20
1792 030.30724 26
1793 030_30725 114
1794 030.30735 128
1795 030.30736 7
179B 030.30742 29
1797 030.3-0744 21
1798 OJ0.30748 14
1799 030.30760 80
ALLOCATED COST
79
32
909
23
79
37
10
3,987
31
132
0a
18
14
28
25
40
122
130
24
48
955
213
1,139
21
30
ATMOS ENERGY CORPORATION, WESTTEXAS OlVISION INtEftlM COSTRECOVERVAND RATE.ADJUSTMENT REPORT
PROJECT REPORT C.Y 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR >016 (2) BENEFITED
INSTALL 30 FEET OF 4 INCH POLY MAIN AND RETIRE 30 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TEXAS RULE 13.2.09 All-MIX INSTALL 11 FEET OF2 INCH POLY MAIN AND RETIRE 11 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 54 FEET OF 2 INC!l POLY MAIN, 13 FEET OF 3 INCH POLY MAIN. 673 FEET OF 4 INCH POLY MAIN, RETIRE 740 FEET OF 6 INCH SH,EL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX lNSTAlL 1 SERVICE, RETIRE 1 SERVICE IN ACCORDANCEWlTH RAILROAD COMMISSlON OF TEXAS RULE 8.209 ALL-MIX INSTALL 129 FEET OF 1.25 INCH POLY MAlNAND RETIRE 129 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX INSTALL22 FEET OF4 INCH POLY MAIN AND RETIRE22 FEET OF 4 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 1 SERVICE, RETIRE 1 SERVICE IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX
REBUILD CPR DUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX INSTALL622FEETOF 2 INCH POLY MAlN, RETIRE620FEETOF2 INCH STEEL MAlN AND 12 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All· MIX INSTALL 990FEET OF2 INCH POLY MAIN. INSTALL 172 FEET OF 4 INCH POLY MAIN. RETIRE 1162 FEET OF STEEL MAIN ANO 1 ASSOCIATED SE;RVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 175FEET OF2 INCH POLY MAIN AND RETIRE 175 FEET OF 3 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 13 FEET OF 2 INCH POLY MAIN AND RETIRE 13 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 10FEETOF2 INCH POLY MAIN AND RETIRE 10FEETOF2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION TO TEXAS RULE 8.209 All-MIX INSTALL 25 FEET OF 2 INCH POLY MAIN, RETIRE 25 FEET OF 2 INCH sTEEl MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 All-MIX INSTALL 27 FEET OF 2 INCH POLY MAIN ANO RETIRE 27 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All· MIX INSTAll 13 FEET OF 2 INCH STEEL MAIN AND RETIRE 13 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 120 FEET OF 2 INCH SlEEL MAIN IN ACCORDANCE WITH RAILROAD COMMlSSION TO TEXAS RULE B.209 ALl-MlX INSTALL 6FEET OF2 INCH POLY MAIN AND RETIRES FEET OF 2 INCH STEEL MAIN IN ACCOROANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All· MIX INSTALL 5 FEET OF 3 INCH STEEL ANO RETIRE 5 FEET OF 3 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS R.Ul.E 8.209 ALL-MIX
INSTALL 699 FEET OF POLY MAIN AND 8 SERVICES AND RETIRE 699 FEET OF STEEL MAIN AND B SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX INSTALL 141 FEET OF 2 INCH POLY MAlN, RETIRE 141 FEET OF 2 INCH STEEL MAlN AND 2 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL· MIX INST ALL 2024 FEET OF 2 INCH POLY MAIN. RETIRE 1984 FEET OF 2 INCH STEEL MAIN AND 32 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WffH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 12FEETOF 2 INOHPOLY MAIN, RETIRE 12 FEET OF 2 INCH POLY MAIN IN AcCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.200 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
8 COMMISSION OF TEXAS RU!.E 8,209 ALL-MIX
25
20
26
114
128
7
29
21
14
so
INSTALL32FEET OF2 INCH POLY MAlN, RETIRE 32 FEET OF 2 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.209 INSTALL 21 FEET OF 2 INCH POLY MAIN AND RETIRE 21 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL25 FEET OF 3 INCH POLY MAIN AND RETIRE.25 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL365 FEET Of 4 INCH POLY MAIN, RETIRE385 FEETOF6 INCH STEEL MAIN IN ACCORDANCE. WITH RA!!.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 150 FEETOf 4 INCH POLY MAIN AND LOWER 100 FEET OF 3 INCH STEEL MAlN AND 50 FEET OF 4 INCH STEEL MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDA~CE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETlRE 1 SE:RVICE IN ACCORDANCE wrn-1 RAILROAD COMMISSION OF TEXAS RULE 8.209
INST ALL 15 FEET OF 4 INCH STEEL MAIN, RETIRE 15 FEET OF 4 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL41 FEETOF2 INCH POLY MAIN. RETIRE41 FEETOF2 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 80 FEET OF 1.25 INCH POLY MAIN AND RETIRE BO FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMM!SSION OF TEXAS RULE 8.209 INSTALL 659 FEET OF 2 INCH POLY MAIN, RETIRE 400 FEET OF 2 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WIX Additians Page46 of9.8
ALL-MIX
All· MIX
ALL-MIX
All- MIX
All-MIX
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MlX
DATE PLACED JN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTCM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
O:ID TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMS10N SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DiVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY.2<J15
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DlVISION SYSTCM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRflY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 ri=xAs btvlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY -201B
030 TEXAS OIVISION SYSTEM INTEGRITY MAY·2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAY.2<'.J16
030 TEXl\S DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTCM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
LINE NO. PROJECT NUMBER COST(11
1800 030.30752 6,559
1801 030.30706 213
1802 030.30756 (1)
1603 030.30759 143
1604 030.30765 167
1605 030.30766 157
1806 030,30766 155
1607 030.30769 441
1608 030.30776" 570
1809 030.30777 5
1610 030.30783 261
1811 030.30793 4
1612 030.30796 233
1613 030.30601 10
1814 030.30603 30
1815 030.30607 15
1816 030.30609 45
1817 030.30810 10
1818 030,30823 10
1619 030.30826 3
1820 030.30627 323
1821 060.30828 30
1822 030.30830 72
1823 030.30632 19
1824 030.30633 21
1825 030.30834 36
1826 030.30840 72
1827 030.30641 18
1820 030.30844 421
1829 030.30850 59
1830 030,30801 60
1831 030.30853 7
1832 030.30854 60
1833 a:m.aoa55 26
1834 030.30856 11
1835 030.30857 66
1636 030.30856 25
ATMOS ENEll;GY CORPORATION. WEST TEXAS DMSION INTEmM C.OST RECOVrnv ANO RATE ADJUSTMENT REPORT
PROJECT REPORTC'i 2016
ALLOCATED DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS COST PUBLIC USE IN CALENDAR YEAR 2016121
INSTALL 12, 167 FEET OF 2 INCH POLY MAIN AND RETIRE 12.167 FEET OF 2 INCH ABS IN ACCORDANCE WITH RAILROAD
Mo9 COMMISSION OF TEXAS RULE 8.209 INSTALL TWO ENCIRCLEMENTS ON 3 INCH STEEL PIPE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
213 6.209 INST ALL 1 SERVICE, RETIRE 1 SERVICE IN ACCORDANCE WITH
'1} RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 167 FEET OF 2 INCH POLY MAIN, RETIRE 167 FEET OF 2 INCH STEEL MAIN AND 5 ASSOCiATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
143 8.209 INSTALL 4 INCH ENCIRCLEMl'NT IN ACCORDANCE WITH
167 RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 2 INCH ENCIRCLEMENT!N ACCORDANCE WlTH
157 RAILROAD COMMISSION OF TEXAS RULE 6.209 !NSTALL 11.25 INCH ENCIRCLEMENT IN ACCORDANCE WITH
155 RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 1648 FEET OF >INCH POLY MAIN, RETIRE 1539FE;ETOF 2 INCH STl'EL MAIN AND 15 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
441 8,209 INSTALL 246 FEET OF 2 INCH POLY MAIN, RETIRE 346 FEET OF 2 INCH STEEL MAIN AND 10 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION PF TEXAS RULE
570 8.209 INSTALL361 FEET OF 2 INCH POLY MAIN, RETIRE381 FEETOF2 INCH STEEL MAIN AND 3 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COM Ml SS IOI-I OFTEXAS RULE
5 8.209 INSTAlL34<l FEETOF2 INCH POLY MAIN. RETIRE;346 FEET OF 2 INCH STEEL MAIN AND 10 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
261 8.209 lNSTALL 1 SERVICE, RETIRE 1 SERVICE IN ACCORDANCE WITH
4 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL ENCIRCLEMENT ON 4 INCH VAL VE AND INSTALL 4 INCH VALVE ON HPLINE IN ACCORDANCE WITH RAILROAD
233 COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
10 COMMISSION OF TEXAS RULE 8.209 INSTALL 45 FEET OF 2 INCH POLY MAIN, RETIRE 41 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
30 COMMISSION OF TEXAS RULE 8.20Ei INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE
15 WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 398FEET OF2 INCHPOLY MAlN. RETIRE 398 FEETOF2 INCH STEEL MAIN AND 2 ASSOCIATED SERVICES IN ACCORDANCE WITH RAil-ROAD COMMISSION OF TEXAS RULE
45 8.209 .REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
10 COMMISSION OF TEXAS RULE B.209 INSTALL 146FEET OF2 INCH POLY MAlN. RETIRE 146FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAlLROA!J
10 OOMMISSION OF TEXAS RULE 8.209 INST ALL 1 SERVICE, RETIRE 1 SERVICE IN ACCORDANCE WITH
3 RAILROAD COMMISSION OF TEXAS RULE 8_209 INSTALL 185Fl'ET OF 1.25 INCH POLY INSERTION ANO .75 INCH POLY AND RETIRE 185 FEETOF2 INCH STEEL MAIN AND 11 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION
323 OF TEXAS RULE 8.209 INSTALL 365FEET OF 1.25 INCH POLY INSERTION ANO .75 INCH POLY AND RETIRE365 FEETOF2 INCH STEEL MAIN AND 21 INCH STEEL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION
30 DF TEXAS RULE 8.209 INSTALL 68 FEET OF 2 INCH MAIN AND RETIRE 68 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF
72 TEXAS RULE 8.209 INSTALL 10 FEET OF 4 INCH STEEL MAIN. RETIRE 10 FEET OF4 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF
19 TEXAS RULE B.209 INSTALL 8 FEET OF 4 INCH STEEL MAIN, RETIRE 6 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSlON OF
21 TEXAS RULE 6.209 INSTALL 23 FEET OF 2 INCH POLY MAIN AND RETIRE 23 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
36 COMMISSION OF TEXAS RULE 8.209
INSTALL WELDOVER ON 3 INCH STEEL MAIN IN ACCORDANCE 72 WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209
INSTALL WELDOVER ON 6 INCH STEEL MAIN IN ACCOROANCI= 18 WITH RAILROAD COMMISSION Of TEXAS RULE 8.209
INSTALL 435 FEET OF2 INCH POLY MAIN AND1 SERVICE AND RETIRE 1471 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
421 8.209
INSTALL 32 FEET OF 2 INCH STEEL MAlN AND RETIRE 32 FEET OF 2 INCH STEEL MAIN AN!J 1 SERVICE IN ACCORDANCE WITH
59 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 42 FEET OF 2 INCH POLY MAIN AND RETIRE 42 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
60 COMMISSION OF TEXAS RULE 6.209 RETIRE 300 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE
7 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
60
26
11
86
25
INSTALL 82 FEET2 INCHPOLY MAIN AND RETIRE 82FEET OF2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 0.209
INSTALL 15 FEET OF 4 INCH STEEL MAIN AND RETIRE 15 FEET OF 4 INCH STEEL MAIN ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE AND RETIRE 1 SERVICElNACCORD/\NCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 36 FEET OF 6 INCH STEEL MAIN AND RETIRE 3S FEET OF 5 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 16 FEET Of2 INCH STEEL MAIN AND RETIRE 16 FEET OF 2 INCH STE;EL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX Addttim,s Page47of9B
BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
llLL·MIX
ALL-MIX
ALL· MIX
ALL- MIX
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN-GASPLANTLN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTCGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MA.Y-2016
030 TEXAS DIVISION sYsrnM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISJON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VISION SYSTl'M INH;GRITY MAY-2016
030 TEXAS DIVJSION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVJSION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2010
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS I
MAY-2016
030 TEXAS DiVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST(1)
1837 030.30861 66
1838 OJ0.30B85 19
1839 030.30868 25
1840 o.so.aoa92 30
1641 030.30893 10
1842 030.30694 3
1843 030.30901 2
1844 030.30903 535
1845 030.30910 (12)
1846 030.30911 96
1847 030.30912 104
1848 030.30943 1,335
1849 o:m.30946 217
1650 030.30961 14
1651 030.30963 9
1652 030.30964 61
1653 030.30977 39
1854 030.30978 162
1El55 030.30979 104
1656 030.30981 208
1657 030.309:86 19
1858 030.30988 18
1859 030.30989 29
18"60 030.30993 10
1861 030.30999 1181
1862 030.31008 147
1863 030.31025 25.639
1864 030.31032 33,255
1865 030.31033 43.997
1855 030.31040 3,947
1867 030,31050 2B
1866 030.31051 42
1869 030.31052 24
1870 030.31053 80
j8fj 030.31054 35
1872 030.31058 55
ALLOCATED COST
66
19
25
30
10
3
ATMOS £NERGY CORPORATION, WEST TEXAS DlVIS.ION INTERIM CO.ST RECOVER'{ Al'40 RATE ADJUSTMENT REPORT
PROJECT REPORT CV 2016
OESCRIPTION OF COMPLETED PROJECTS DEDJCATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 (2) BENEFITED
INSTALL 97 FEET OF 2 INCH STEEL MAIN, RETIRE 97 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 93 FEET OF 2 INCH STEEL MAIN, RETIRE 93 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 42 FEET OF 2 INCH STEEL MAIN, RETIRE 42 FEET OF 2 INCH STEEL MAIN AND 2 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 27 FEET OF 2 INCH POLY MAIN AND RETIRE 27 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 24 FEET OF 4 INCH POL V MAIN AND RETlRE 2.4 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX RETIRE 1 SERVICE IN ACCORDANCE WlTH RAILROAD
2 COMMISS[ON OF TEXAS RULE 6.209 ALL-MIX
535
(121
96
104
1,335
217
14
9
61
39
162
104
208
1•
18
29
10
(18)
147
25.639
33,255
43,997
3,947
26
42
24
BO
35
56
INSTALL WELDOVER ON 8 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 7 FEET OF 2 INCH STEEL MAIN, RETIRE 7 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 40 FEET OF 2 INCH STEEL MAIN, RETIRE 40 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8,209 RETIRE 29 FEET OF 1 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WtTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL278 FEET OF 2 INCH POLY MAIN. RETIRE 278 FEET OF 2 INCH STEEL MAIN AND 8 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 110 FEET OF 2 INCH POLY MAIN, RETIRE 110 FEET OF 2 INCH STEEL MAIN AND 3 ASSCIATED SERVCIES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INST ALL WELDOllER ON 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET OF 3 INCH STEEL AND RETIRE HEET OF 3 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 4 SERVICES IN ACCORDANCE WlTH RAILROAD COMMISSJON OF TEXAS RULE 8.209
INSTALL 5 FEET OF 3 INCH STEEL MAIN, RETIRE 5 FEET OF 3 INCH STEEL MAIN, AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 120 FEET OF 4 INCH POLY MAIN, RETIRE 120 FEET OF 6 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 171 FEET OF 4 INCH POLY MAIN, RETIRE 172 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMM!SSION OF TEXAS RULE 8.209 INSTALL 21 FEET OF 2 INCH POLY MAIN AND RETIRE 21 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 12 FEET OF 2 INCH POL V MAIN AND RETIRE 12 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 INSTALL 7 FEET OF 4 INCH STEEL MAIN AND RETIRE 7 FEET OF 4 INCH STEEL MAIN l>l ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL250FEET OF2 INCH POLY MAIN, RETIRE250fE.ET OF2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 14 FEET OF 4 INCH STEEL MAIN, RETIRE 14 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 721 FEET OF 4 INCH STEEL MAIN AND REPLACE 12 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 4200 FEET OF 2 INCH POLY MAIN AND 58 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 5280 FEET OF 2 INCH POLY MAIN AND 76 SERVICES AND RETIRE 5280 FEET OF 2 INCH STEEL MAIN AND 76 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 9197 FEET OF 2 INCH POLY MAIN AND 257 SERVICES AND RETIRE 12106 FEET OF 4 INCH STEEL MAIN AND 257 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 450 FEET OF 4 INCH STEEL MAIN AND RETIRE 450 FEET OF 4 INCH STEEL MAIN DUE TO PUBUC IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL21 FEET OF 4 INCH POLY MAIN, RETIRE21 FEETOF4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 14 FEET OF 3 INCH STEEL MAIN, RETIRE 14 FEET Of a INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 3 FEET OF3 INCH STEEL MAIN, RETiRE 3 FEET OF 3 lNCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 21 FEET OF 1 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209
INSTALL 26 FEET OF 3 INCH STEEL MAIN, RETIRE 26 FEET OF 3 INCH STEEL MAIN ANO 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX Additian:s Page 4.8 of 98
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL- MIX
A!.L-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED tN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVIC:E
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
o:m TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS Dtv!SION SYSTEM INTEGRITY MAY-2016'
030 TEXAS DIVISlON SYsTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ~2.016
030 TEXAS DMSION SYSTEM INTEGRITY MAV-2.016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION PUBUC IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY !vlAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST(1)
1873 030.31069 144\
1874 030.31071 1,045
1B75 030.31073 133
1876 030.31075 22
1877 030.31081 63
1878 030.31085 23,:263
1879 030.31093 42.314
18BO 030.31100 85
1581 030.31103 8
1882 030_31104 2
1883 030.31107 24
1884 030.31112 142)
1885 030.3111• 980
1886 000.31120 17
1887 030.31121 122)
1aaa 030,31128 706
1689 030.31129 BO
1890 030.31130 57
1891 o:m.a11at (5Bl
1892 o:m.31135 116
1893 030.31137 1.888
1894 030.31157 1521
1B95 030.31171 83
1896 030.31180 1371
1897 0•0.31181 1105}
1898 oao.311a2 79
1899 030.31183 50
1900 030,31196 318
1901 030.31200 24
1902 030.312.05 4,753
1903 030.31207 194
1904 030.31210 18,991
1905 030.31211 22,898
1900 030.31220 503
ALLOCATED COST
1441
1,045
133
22
63
23,263
42.314
85
8
ATMOS ENERGVCO~l'ORATION, WBTTEXl\5 DIVISION INTERIM COST RECOVERY AND RA'l'E ADJUSTMENT REPORT
F'ftOJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDJCATEO TO CUSTOMERS PUBLIC US!; JN CALENDAR VEAR 2016 (2) BENEFITED
REPLACE METER AND REGULATOR STATION COMPONENTS AT CRESTVIEW ELEMENTARY !N LUBBOCK IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 465 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 465 FEET OF 2 INCH PLASTIC MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.200 ALL-MIX INSTALL 53 FEET OF 2 INCH STEEL MAIN. RETIRE 53 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 ALL-MIX INSTALL 9 FEET OF 2 INCH STEEL MAIN, RETIRE 9 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMJSSIDN OF TEXAS RULE 8.209 ALL-MIX JNSTALL 524 FEET OF 2 INCH PPLY MAIN, 218 FEET OF 4 INCH POLY MAIN, RETIRE 524 FEET OF 2 INCH STEEL MAIN AND 16 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL6453 FEET OF 2 INCH AND809 FEET OF 4 INCH POLY MAIN AND 38 SERVICES AND RETIRE 8015 OF 2 INCH STEEL MAIN AND 38 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL3450 FEET OF 4 INCH AND 19476 FEET OF2 INCH POLY MAIN AND RETIRE 22926 FEET OF 2, 3, AND 5 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 574 FEET DF2 INCH POLY MAIN. RETIRE610fEETOF2 INCH STEEL MAIN AND 2 ASSOCIATED SERVICES lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE
2 WITH RAILRDAO COMMISSION OF TEXAS RULE B.209 ALL-MIX
INSTALL 16 FEET OF 3 INCH STEEL MAIN AND RETIRE 16 FEET OF 3 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH
24 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE
142) WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 828 FEET OF 1.25 INCH POLY MAIN AND RETIRE82B FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAR-ROAD
9BO COMMISSION OF TEXAS RULE B.209 INSTALL 513 FEET OF 2 INCH POLY MAIN, RETIRE 513 FEET OF 2 INCH STEEL MAIN AND 4 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
17 B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
(22) COMMISSION OF TEXAS RULE 8.209 REPLACE METER AND REGULATOR STATION COMPONENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
706 8.209 RETIRE 125 FEET OF 2 INCH STEEL MAIN AND 3 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION TO
80 TEXAS RULE B.209 INSTALL 12 FEET OF 4 INCH STEEL MAIN, RETIRE 12 FEET OF 4 INCH STEEL MAIN AND 1 SERVICES IN ACCORDANCE WITH
57 RAILROAD COMMISSlON OF TEXAS RULE B.209 INSTALL 45 fEETOF 4 INCH POLY MAIN AND RETIRE 45 FEET OF 4 INCH sTEEl. MAIN AND 1 SERVICE IN ACCORDANCE WITH
1581 RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 6 INCH WELDOVER IN ACCORDANCE WITH RAllROAD
116 COMMISSION OF TEXAS RULE 8.209 RETIRE 200 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH
1,888 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 48 FEET OF 4 INCH POLY MAIM AND RETIRE 4B FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(521 COMMISSION OFTEXAS RULE 8.209 REPLACE 4BO FT OF 3 INCH STEEL WITH 460 FT OF 4 INCH HOPE WITH 4 SERVICES IN ACCORDANCE WITH RAILROAD
83 COMMISSlONOFTEXAS RULE 8.209
(37)
1105
79
50
318
24
4,753
194
18,991
22.898
503
INSTALL 10 FEET OF 4 INCH STEEL MAIN AND RETIRE 10 FEET OF 4 STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5& FEET OF 3 INCH POLY MAIN, RETIRE 60 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 IMSTALL 183 FEET OF 2 INCH POLY MAIN, RETIRE 183 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL520 FEETOF2 INCH POLY MAIN, RETIRE769 FEET OF 2 INCH STEEL MAIN AND 4 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL847 FEET OF 2 INOHPOLY MAIN, RETIRE71 FEET OF 3 INCH STEEL MAIN ANO 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 1156FEETOF2 INCH POLYMAIN.181 FEET OF 4 INCH POLY MAIN, RETIRE 1337 FEET OF 3 INCH STEEL MAIN AND 11 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUL<O B.209
INSTALL 19 FEET OF 4 INCH STEEL MAIN, RETIRE 19 FEET OF4 INCH STEEL MAIN, AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 1111 FEET OF 4 INCH PPLY MAIN AN!l 4062 FEET OF 2 INCH POLY MAIN AND 85 SERVICES AND RETIRE 5173 FEET OF 4 AND 2 INCH STEEL MAIN AND 85 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 1448 FEET OF 4 INCH POLY MAIN ANO 6229 FEETOF2 INCH POLY MAIN AND 146 SERVICES AND RETIRE 7677 FEET PF 6, 4, AND 3 INCH STEEL MA!N AND 14£ SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 11 FEETOF6 INCH STEEL MAIM AND 17FEETOF4 INCH POLY MAIN AND RETIRE 11 FEET OF 6 INCH STEEL MAIN i\ND 17 FEET OF 4 INCH STEEL MAIN JN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 0.209
WTXAddltlons 11.age49of98
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 H'XAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION sysu;M INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OIVISJON SYSTEM INTEGRITY MAY-2016
0'30 lEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVJSION SYSTEM INTEGRITY MAY-2<l16
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRl1Y MAY-2016
030 TEXAS DIV!SION SYSTEM INTEGRITY ocroatR . 2ois
030 TEXAS D!VISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
o•o TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
o:io TEXAS DIVISION SYSTEM INTEGRITY MAY~2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COSTC11
1907 030.31222 134)
1908 030.31231 151
1909 030.31239 1.246
1910 030.31240 83
1911 030.31241 19
1912 030.31242 36
1913 030.31243 1271
1914 030.31244 (271
1915 030.31245 93
1916 030.31246 18
1917 030.31250 19
1918 030.31259 77
1919 030.31261 I 1,141
1920 030.31264 1.765
1921 030.31265 4
1922 030.31271 36
1923 030,312.78 165
1924 030.31279 42
1925 030.31281 (28)
192.6 030.31282 (013
1927 030.31284 [55)
1928 030.31286 36
1929 030.31287 33
1830 030.31288 122)
1931 030.31289 {71)
1932 030.31290 52
19J3 030.31292 290
1934 030.31200 1,698
1935 030.31297 54
1936 030.31300 10,176
1937 030.31302 104
1938 030.31303 18
1939 oao.:uaoa 229
1940 030.31309 312
1941 030.31324 439
1942 030.31325 187
1943 030.31326 304
1944 030.31327 110
1945 030.31326 365
194<1 030.31341 111
ALLOCATED COST
134'
ATMOS ENERGY CORPORATION, WESTTEXAS DIVISION INTERIM COST FIECOVERV AND RATE ADJUSTMENT REPORT
PROJECT REPO~ CY 2016
DESCRIPTION OF COMPLETED PROJECTS DECICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 [21 BENEFITED
INSTAU. 12 FEET or 6 INCH POLY AND RETIRE 12 FEET OF 6 lNCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULEB.209 ALL-MIX INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE
(5) WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX INSTALL 14 FEET OF 4 INCH STEEL MAIN AND RETIRE 14 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WIT>l RAILROAD
1,246 COMMISSION OF TEXAS RULE 8.209 INSTALL 852 FEET OF 2 INCH POLY MAIN ANDRETIRE657 FEET OF 2 INCH STEEL MAIN AND 4 ASSOCIATED SERVlCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
83 8,209 RETIRE ONE SERVlCE IN ACCORDANCE WITH RAILROAD
19 CDMMISSION OF TEXAS RULE 5.209 RETIRE 11 INCH STEEL SERVICE IN ACCORDANCE WITH
36 RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL 24 FEETOF3 INCHSTEEL MAIN AND RETIRE24 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
127 COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVlCE, RETIRE 1 SERVICE IN ACCORDANCE WITH
(27 RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 1 INCH POLY SERVICE IN ACCORDANCE WJTH
9J RAiLROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 11 INCH STEEL SERVICE IN ACCORDANCE WITH
18 RAILROAD COMMISSION OF TEXAS RULE 8.209
RETIRI' 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE 19 WITfl RAILROAD COMMISSION Of TEXAS RULE; B.209
INSTALL 90 FEET OF 2 lNCH POLY MAIN AND RETIRE 90 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
77 COMMISSlON OF TEXAS RULE 8.209
INSTALL432 FEETDF 2 INCH PDLYMAIN, RETIRE634 FEET OF 3 INCH STEEL MAIN AND 2 ASSOCIATED SERVICE IN ACCORDANCE
1,141 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 470 FEET OF 2 INCH POLY MAIN AND 6 SERVICES AND RETIRE 470 FEET OF 2 INCH STEEL MAIN AND 6 SERVICES IN ACCORDANCE Wfffl RAILROAD COMMISSION OF TEXAS RULE
1,766 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD
4 COMMISSION OF TEXAS RULE 8.209
38
165
42
f2l.\)
[213)
(55)
36
33
(221
1711
52
290
1.698
54
10.176
104
18
229
312
439
187
304
110
365
111
RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 14 FEET OF 4 INCH STEEL MAIN AND RETIRE 14 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE !N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 40 FEET OF 3 INCH POLY MAIN, RETIRE 40 FEET OF 3 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 5.209
INSTALL 466 FEET OF 4 INCH POLY MAIN AND 3 SERVICES AND RETIRE 4<16 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL27 FEET OF 41NCH POLY MAIN, RETIRE 27 FEET OF 4 INCH STEEL MAIN AND 1 ASSOCIATED SERVICE !N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.20.9 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 5.200 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION DFTEXl\S RULE 8.21!!1 INSTALL 146 FEET OF 2 INCH POLY MAIN THROUGH 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE6.209 INSTALL 87 FEET OF 4 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 15 FEET OF 2 INCH SIEEL MAIN, RETIRE 15 FEET Of 2 INCH STEEL MAIN, AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REESE CENTER LVM FROM OBSOLETE R5000 TO 3M RODTSMETERIN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 460 FEET OF 4 INCH POLY MAIN AND RETIRE 3BOFEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
INST ALL 97 FEET OF 2 INCH POLY MAIN AND 3 SERVICES AND RETIRE 97 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.21!!1 lNSTALL 270 FEET OF 8 INCH STEEL MAIN AND RETIRE 270 FEET OF 8 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE SERVICE IN AcCORDANCE WITH RAILROAD COMMISSION DF TEXAS RULE B.209 RETIRE 11 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION DF TEXAS RULE 8.209 INSTALL 40 FEETOF2 INCH STEEL MAIN AND RETIRE40 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE Wl1H RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 76 FEET OF 4 INCflPOLY MAIN AND RETIRE 76FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 2B FEET OF 2 INCH POLY MAIN AND RETIRE 26 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 11 FEETOF2 INCH POLY MAIN AND RETIRE 11 FEETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD OOMMISSION Of TEXAS RULE 8.21!!1 INST ALL 10 FEET OF 2 INCH STEEL MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMJSS!ON OF TEXAS RULE S.2.09 INSTALL 2 INCH STEEL MAIN AND RETIRE 2 INCH STEEL MAIN IN ACCORDANCE WITH RAlLROAD COMMISS!DN OF TEXAS RULE 8.2.09 RETIRE 25 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITli RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 7 FEET OF 21NCH POLY MAIN AND RETIRE 7 FEET OF2 INCH PLASTIC MAIN AND 1 SERVICE ~N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTXAdditions Piige 50 of98.
ALL-MIX
ALL-MIX
ALL-MIX
/\LL-MIX
ALL-MIX
ALL- MIX
ALI.- MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
AL!--MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL- M!X
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM ll>ITEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVIS!ON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIV~S!ON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISiON SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2010
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 IEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAYM2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED No. PROJECT NUMBER COST(1) COST
1947 030.31347 349 349
1948 030.31346 475 475
1949 030.31349 229 229
1950 030.31352 575 575
1951 030.31353 824 824
1952 030.31355 115 115
1953 030.31361 119 119
1954 O'l0.31363 374 374
195.5 030.31364 236 236
1956 030.31368 100 100
1957 030.31369 133 133
1958 030.31372 58 58
1959 030.31373 115 115
1:960 030,31374 330 330
1961 030.31390 53 53
1962 030.31393 52 52
1963 030.31398 58 58
1004 030.31399 213 213
1965 030.31400 336 336
1966 o:m.31402 464 484
1967 030.31408 295 295
1968 03-0.31501 184 184
1969 030.31600 104 104
1970 030.31603 288 288
1971 030.31604 122 122
1972 030.31605 40 40
1973 030.31606 14 14
1974 030.316i1 199 199
1975 030.31614 116 116
1976 030,31815 254 254
1977 030.31618 301 301
1978 030.31627 140 140
1979 030.31754 318 318
1980 030.31756 397 397
1981 050.31764 339 339
1982 030.31765 81 81
198.'l 030.31786 87 87
1984 030.31779 123 123
ATMOS ENE.RGV CORPORATION, WE$TTEXA5 OlVISION INfCRIM COST RECOVERY AND RATE AOJUSTMENr R.EPORT
PROJECT REPORT 0/ 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (21
INSTALL 45 FEET OF 4 INCH STEEL MAIN AND 1 SERVICE AND RETIRE 45 ~EET OF 4 INCH STEEL MAlN IN ACCORDANCE: Wl!H RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL229 FEET OF 2 INCH POLY MAIN AND 5SERVICESAND RETIRE 229 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 15 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 15 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a,209 INST All aa FEET OF 4 INCH POL y MAIN AND RETIRE 88 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1539 FEET OF 2 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 8 SERVlCES IN ACCORDANCE WITH RMLROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 282 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 137 FEET OF 2 INCH STEEL MAIN AND RETIRE 137 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200 INSTALL 21 FEET Of 2 INCH STEEL MAIN AND RETIRE 21 FEET OF 2 INCH STEEL MAIN lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200 INSTALL 43 FEET OF 4 INCH STEEL MAIN AND RETIRE 43 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMlSSIDN OF TEXAS RULE 8.209 INSTALL 75 FEET OF 2 INCH STEEL MAIN AND RETIRE 75 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 2 INCH ENCIRCLEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 ENCIRCLEMENT IN ACCORDANCE WITH RAlLROAD COMMISSlON OF TEXAS RULE 6.209 INSTALL 11 FEET OF 2 INCH STEEL AND 1 SERVICE AND RETIRE 11 FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 11 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 4 TAPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 10 FEET OF 2 INCH STEEL MAIN AND RETIRE 1 DRESSER COUPUNG AND 10 FEET OF 2 INCH SlEEL MAIN IN ACCORDANCE WITH RAllROAD COMMISSION OF lEXAS RULE 8.209 INSTALL 6 FEET OF 2 INCH PIPE AND RETIRE 6 FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 94 FEETOF2 INCH POLY MAIN AND RETIRE 94 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209
INSTALL 20 FEET OF 2 INCi-i STEEL MAIN AND 1 SERVICE AND RETIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 lNSTALL 1 .75 INCH POLY SERVICE AND RETIRE 11.25 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.209 INSTALL 1.75 INCH POLY SERVICE AND RETIRE 11.25 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 .75 INCH POLY SERVICE WITH 11 INCH STEEL SERVICE IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8,209
REPLACE 1 1 INCH STEEL SERVICE AND METER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 32 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 32 FEET OF 2 INCH STEEL MAIN 11-l ACCORDANCE WITH RAJLROAD COMMISSION OFTEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INST ALL 13 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE AND RETIRE 13 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INST ALL 0.75 INCH PIPE ANO RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE B.209 INSTALL 6 FEET OF 2 INCH STEEL MAIN AND RETIRE 6 FEET OF 2 INCH STEEL MAiN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 18 FEET OF 4 INCH STEEL MAIN AND 1 SERVICE AND RETIRE 18 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTA\.L 250FEETOF2 INCH POLY MAIN AND RETIRE250 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 1 2 INCH WELD AND 5 FEET OF 2 INCH STEEL MAIN /\ND REPLACE 1 2 INCH GATE VALVE AND 5 FEE.T OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 12 INCH WELD AND 5 FEET OF 2 INCH STEEL MAIN AND REPLACE 1 2 INCH GATE VALVE AND 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULi:;. B.209 INSTALL 0. 75 INCH SERVICE AND RETIRE 1.5 INCH SERV!CE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.200 REPLACE 18 FOOT SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 1 "SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 85 FEET OF 2 INCH POLY MAIN AND RETIRE 65 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WlXAddltlons
Page51of9$
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MlX
ALL- MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MlX
ALL-MIX
AL!.·MIX
ALL- MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
Ali.· MIX
ALL· MIX
ALL-MIX
All-MIX
All-MIX
ALL· MIX
ALL-MIX
ALL-MIX
All-MIX
DATE PLACED IN GASPIANTIN
LOCATlOr.I PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 lEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAV-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRtlY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
O'lO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSJON SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY -2016
030 TEXAS DIVISION SYSTEM !NTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
UNE Al.LOCATED No. PROJECT NUMBER COST(1J COST
1965 030.31761 167 167
1986 030_31794 326 32B
1987 030.31799 48 46
1988 030.31814 76 78
1989 030.31815 39 39
1990 030.31817 79 79
1991 030.31829 14 14
1992 030.31833 225 225
1993 030.31836 1a 15
1994 030.31849 60 60
1995 030.31850 475 475
1996 030.31857 503 503
1997 030.31853 501 51J1
1998 030.31864 294 294
1999 030.31B71 345 345
2000 030.31678 85 85
2001 0:30,31879 279 279
2002 030.31883 312 312
2003 030.31884 126 126
2004 030,31890 479 479
2005 030.31891 113 113
2006 030.31900 293 293
2007 030,31913 199 199
2008 030.31914 75 75
2009 030.31915 89 89
2010 030.31916 96 96
2.011 030,31925 373 373
Z012 030_31927 23 23
2013 030.31949 293 293
2014 030_31955 4,304 4,304
2016 030.31959 6,328 6,328
2016 I 030.31960 186 186
2017 030.31965 166 166
2018 030.31970 549 549
2019 030.31972 042 542
2020 030.31990 56 SB
AlMOS ENERGY CORPORATION, WEST TEXAS OIVISION INTERIM cosr RECOVERY ANO AATE ADJUSTMENT FIEPORT
PROJECT REPORT CY 2016
DESCRIPTIOJll OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 16 FEET OF 3 INCH STEEL MAIN AND RETIRE 16 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2 INCH WELDOVER ON DRESSER COUPUNGIN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL61 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 61 FEET OF Z INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL o9FEETOF2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 59 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALLB2FEET DF2 INCH POLY MAIN AND RETIRE 62 FEETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD CDMMISSJONOFTEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 11 FEET DF2 INCH POLY MAlNANDRETIRE 12 INCH GATE VALVE AND 705 FEET DF 2 INCH sTEEL AND 972 FEET OF 3 INCH STEEL AND 3796 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETlRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION DF TEXAS RULE 8,209 RETIRE 125 FEET OF 2 lNCH STEEL MAIN ANO 225 FEET OF 2 INCH STEEL MAIN AND INST ALL 225 FEET OF 2 INCH POLY MAIN tN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTAUL 25 FEET OF STEEL MAIN AND 2 SERVICES AND RETIRE 25 FEET OF STEEL MAIN IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE B.209 INST ALL o FEET OF POLY MAIN AND 1 SERVICE AND RETIRE 5 FEET OF STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL44 FEET OF 21NCH POLY MAIN AND RETIRE44 FEET OF2 INCH STEEL MAIN JN ACCORDANCE WITH Rl\ILRDAD COMMISSION OF TEXAS RULE 8.209
INSTALL 205 FEET OF 1.25 INCH POLY MAIN AND 2 SERVICES AND RETIRE 205 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE :B.209 INSTALL 1 .75 INCH POLY SERVICE AND RETIRE 1 1 INCH STEEL SERVlCE lN ACCORDANCE WITH RAilROAD COMMISSION OF 1EXAS RULE 8_209 INSTALL 2 .75 INCH POLY SERVICES AND RETIRE Z 1.25 INCH STEEL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200 INST All 32 FEET OF 2 INCH STEEL MAIN AND RETIRE 32 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RM-ROAD COMMISSION OF TEXAS RULE B.209 INSTALL 202FEET DF2 INCH POLY MAIN AND REPLACE 202 FEET OF 2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 10 FEET OF 3 INCH STEEL MAIN AND RETIRE 1 O FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 16 FEET OF 3 INCH STEEL MAIN ANO RETIRE 16 FEET OF 3 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL WELDDVER IN ACCORDANCE WffH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 70 FEET OF 2 INCH POLY MAIN AND RETIRE 70 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 137 FEET OF 2 INCH POLY MAIN AND 3 SERVICES AND RETIRE 137 FEET Of 2 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST AUL 10 FEET OF 2 INCH l'OLYMAIN AND RETIRE 10 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 INST All 205 FEET OF 2. INCH POLY MAIN AND 7 SERVICES AND RETIRE 205 FEET OF 2 INCH SlEEL MA3N AND 7 SERVICES IN ACCORDANCE wrn-1 RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 260 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 230 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 2 IDLE SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 19 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES AND RETIRE 19 FEET OF 2 INCH STEEL MAIN iN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 1220 FEET OF 2 INCH POLY MAIN AND 20 SERVICES AND RETIRE 1220 FEET OF 2 INCH STEEL MAIN AND 20 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 415 FEET OF 4 INCH STEEL MAIN AND 7 SERVICES IN AccoRDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8,209 INSTALL 240 FEET OF 2 INCH POLY MAIN AND 8 SERVICES AND RETIRE 240 FEET OF 2 INCH STEEL MAIN AND 8 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 28 FEET OF 2 INCH STEEL MAIN AND RETIRE 28 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 30 FEET OF 2 INCH STEEL MAIN AND RETIRE 30 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD CDMMISSIONOFTEXAS RULE 8.209 INSTALL40FEET DF2 INCfl POLY MA!NAND RETIRE40 FEET DF2 INCH STEEL MAIN !N ACCO~DANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209
WO( Additions Page 52 of98
CUSTOMERS BENEFITED
ALL-MIX
ALl·MIX
AUL- MIX
AUL· MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All- MIX
ALL· MIX
ALL-M!X
ALL-MIX
All-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE Pt.ACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYsTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 n;xAs DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2018
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VIS!ON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·20tB
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-Z015
030 TEXAS DMSJON SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED No. PROJECT NUMBER COST(1) COST
2021 030.31993 426 426
2022 030.31.996 42 42
20'23 030.31997 44 44
20'24 030.31998 239 239
202:5 OJ0.32005 252 252
2026 030.32006 626 626
21l27 030.32008 200 286
2028 030.32010 104 104
2029 030.32012 703 700
2030 000.32016 1,178 1.178
2031 030.32020 482 482
2032 030.32023 91 91
2033 030,32024 2.416 2.416
2034 030.3202.5 369 369
2.035 030,32026 118 178
2036 030.32027 12,642 12,642
2037 030.3202B 65.917 65,917
2036 030.32029 3,145 3,145
2039 030.32030 4,646 4,546
2040 030.32031 15,700 15,700
2041 030.32032 1,897 1,897
2042 030.32034 19,399 19,399
2043 030.32035 4,984 4,984
2044 030.320:36 68,028 68,028
2045 030.32037 5,025 5,025
2045 030.32039 4,022 4,022
2047 030.32040 7,954 7,954
2048 030,32041 10,786 10.766
21)49 030.32042 26,632 26,632
2050 030.'32043 2,8'3'7 2,637
2051 030.32044 36,266 3'3.266
2052 030.32045 1,935 1,935
ATMOS ENERGY CORPORATION, WESTT<XAS OIVISION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT C'l 2016
DESCRLPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 113 FEET OF 2 INCH POLY MAlN AND 113 FEET OF 2 tNCH STEEL MAIN IN ACCORDANCE WITH RAiLROAD COMMISSION OF TEXAS RULE 8,209 RETIRE B4 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8-209 RETIRE 498 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 6.209 INST ALL 41 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 41 FEET OF 2 INCH STEEL MAlN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.2.09 INSTALL 1S FEET OF 3 INCH POLY MAIN AND RETIRE 16 FEET OF3 INCH STEEL MAlN IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 57 FEET OF 4 INCH POLY MAIN AND RETIRE 57 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE B.209 INSTALL 25 FEET OF 3 INCH POLY MAIN ANDRETIRE25 FEET OF 3 INCH ST<EL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 10 FEET OF 2 INCH STEEL MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200 INSTALL 74 FEET OF 2 INCH POLY MAIN AND RETIRE 2 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS .RULE 8.209 INSTALL 77 FEET OF 3 INCH STEEL MAIN AND RETIRE 77 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACED 1 SERVICE lN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 505 FEET OF 2 INCH POLY MAIN AND 11 SERVICES AND RETIRE 503 FEET OF 2 INCH STEEL MAIN AND 11 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 6 INCH WELDOVER IN ACCORDANCE WffH RAlLROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS AND MET<R LOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209
LUBBOCK OPERATIONS BLANKET TO COllER REPLACE/RETIRE TASKS: MET<RS, REGULATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISSfON OF TEXAS RULE 8.209 LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS AND METER LOOPS IN ADCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE B.209 LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 UTILEFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS AND METER (.OOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 UTILEFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISS!ON OF TEXAS RULE; 8.209 PLAINVlEW OPtRATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS AND METER LOOPS IN ACCORDANCE W!IH RAILROAD COMMISS!ON OF TEXAS RULE 8.209 PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METIORS, REGULATORS AND MErnRLOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 AMARILLO OPERATIONS BLANKET TO COllER REPLACl'/RETIRE TASKS: METERS, REGULATORS AND METER LOOPS IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 PLAINVIEW OPERATIONS BLANKET TO COllER REPLACE/RETIRE TASKS: METERS, REGULATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2.09 PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMET<R. ANODES, METERS, REGULATORS AND METER IN ACCORDANCE WITK RAILROAD COMMISSION OF TEXAS RULE 8.21l9 PAMPA OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: METERS, REGULATORS ANO METER LOOPS IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 5.209 HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS AND METER LOOPS IN ACCORDANCE WITH RAil-ROAD COMMISSION OF TEXAS RULE B.209
HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: MET<RS, REGULATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RlJLE 8.209 MIDLAND/ODESSA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS ANO METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISS~ON OF TEXAS RULE 8.21l9 MIDLAND/ODESSA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RllLE 8.209
WlX AdditiODS Page 53 of 98
CUSTOMf:;RS 13.ENEFtrEO
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- Mtx
ALL-MIX
All-MIX
All-MIX
ALL-MIX
All-MIX
ALL-MIX
DATI:. PLACED Ill.I
GAS PUNT IN LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSlON SYSTEM INTEGRITY MAY-21l16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-21l15
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYST<M INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY D~CEMBE:.R- 20j6
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVISION SYSTEM lNTEGRITY DECEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRllY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016 ;
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRtTY DECEMBER - 2016
030 TEXAS DlVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRlTY DECEMBER- 2016
o:m TEXAS DIVISION SYSTEM INTEGRITY DECEMBER- 2016
030 TEXAS DIVISION SYSTEM INT<GRITY SEPrnMBER-2016
030 TEXAS DIVISION SYSTEM iNTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER- 2016
LINE ALLOCATED NO. PROJECT NUMBER COST[1f COST
2053 030,32046 11.668 11,66B
2054 030.32047 706 706
2055 030.32048 a,so3 8,603
2056 030,3204:9 463 463
2057 030.32057 522 522
2058 030.32059 231 231
2059 030.32062 623 623
:mso 030.32056 122 122
2061 030.32074 189 189
2062 030.32075 284 284
2063 030.32083 60 60
2064 030.32084 301 301
2066 030.320135 1,152 1,152
2066 030.32087 228 228
2067 030,320:99 3,237 3,237
2068 030.32137 5,032 5,032
2069 030.32138 3,089 3,089
2070 030,32142 1.o47 1,047
2071 080.32143 2,209 2,209
2072 030.32145 5,222 5,222
2073 030.32148 2,168 2,166
2074 030,32149 832 S32
2075 030.32162 48 46
2076 030.32164 509 509
2077 030.32100 208 208
2078 030,32171 130 130
2079 030.32172 74 74
2080 OJ0.32181 210 210
2081 030.32167 116 118
2082 03-0.32192 2.101 2.101
2.083 030.32194 2,821 2,821
2084 030.32197 30.868 30,366
ATMOS £NER-GY CORPORATION, WEST T£>1AS DlVISION lNTERIM COSl' RECOVERY ANO RATE ADJUsrMf Nr ~EPORT
PROJECT REPO~T CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUSLIC USE IN CALENDAR YEAR2016 [2)
BIG SPRING OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERV!CE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TAsKS: METERS, REGULATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.>09 SEMINOLE/BROWNFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS. REGU!.ATORS AND METER LOOPS IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TEXAS RULE 0.209 SEMINOLEIBROWNFIELD OPERAT!ONS BLANKET TO COVE~ REPLACE/RETIRE TASKS; METERS, REGUl.ATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TS:AS RULE El.20.9 INST ALL 5 FEET OF 2 INCH STEEL MAIN AND 5 FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULES.209 HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 211 FEET OF 2 INCH STEEL POLY MAIN AND 4 SERVICES AND RETIRE 211 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 INSTA!.L 18 FEETOF2 INCHPOLY MAIN ANO 1 SERVICE AND RETIRE 2 INCH STEEi. MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of H'XAS RULE S.209 INST ALL 75 INCH POLY SERVICE AND RETIRE 1.25 INCH SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.200 INSTALL .75 INCH POLY SERVICE AND RETIRE 1.25 INCH SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 202 FEET Of 2 INCH PO!. Y MAIN AND 2 SERVICES AND RETIRE 202 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 176 FEET OF 2 INCH POLY MAIN AND 4 SERVICES AND RETIRE 176 FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 18 FEET OF 6 INCH STEEL MAIN AND RETIRE 18 FEET OF 8 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 12 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RE!lUll.D LARGE VOLUME METER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: METERS, REGULATORS AND METER LOOPS IN ACCORDANCE WJTH RAILROAD COMM!SSION OF TEXAS RULE 8.209 PAMPA OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: METERS, REGUlATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 315 FEET OF 1.25 INCH POLY MAIN AND 1 SERVICE AND RETIRE 315 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 7 48 FEET OF POLY MAIN AND 3 SERVICES AND RETIRE 748 FEET OF STEEL MAIN IN ACCORDANCE WITH RAILROAO COMMISSION OF TEXAS RULE 6.209 INSTALL 449 FEET OF 4 !NCH AND 135 FEET OF 2 INCH POLY MAIN AND 11 SERVICES AND RETIRE 360 FEET OF 3 INCH AND 447 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 13FEET OF6INCHAND101 FEETOF3 INCH STEEL MAIN AND RETIRE 13 FEET OF 6 INCH AND 101 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 43 FEET OF 4 INCH STEEL MAIN ANO RETIRE 43 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 127 FEET OF >INCH POLY MAIN AND 2 SERVICES AND RETIRE 127 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 1900 FEET OF 2. INCH PLASTIC MAIN IN ACCORDANCE wnH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 74 FEET OF POl.YMAIN AND2 SERVICES AND RETIRE 74 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 6.209 INST ALL 40 FEET OF 2 INCH POLY MAIN AND RETIRE 40 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 46 FEET Of 2 INCH POLY MAIN AND 1 SERVICE ANO RETIRE 46 FEET IF 2 INCH BTEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 12 FEET OF 2 INCH STEEL MAIN AND RETIRE 12 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 7 FEET OF2 INCfl STEEL MAIN, RETIRE 7 FEET OF 21NCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 276 FEET OF 4 INCH PO\. Y MAIN AND 4 SERVICES AND RETIRE 286 FEET OF 4 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REROUTE 700 FEET OF 2 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 6235 FEET OF 2 INCH POLY MAIN AND 80 SERVICES AND RETIRE 6235 FEET OF 2 INCH STEEL MAIN ANO 80 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WT)( Additions Page 54 of9a.
CUSTOMERS BENEFITED
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL· MIX
ALI.-MIX
ALL-MIX
ALL· MIX
ALL.MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
Al.L·MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
AL!.·MIX
ALL-MIX
ALI.-MIX
ALL-MIX
ALl·MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
DATE PLAC::ED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
03-0 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVIStON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAY-2016
030 TEXAS OIVISION SYSTEM INTEGRITY MAY· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OC"JUBER a 2016
000 TEXAS DIVlSION SYSTEM INTEGRITY SEPTEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER~ 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXJ\S DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIV(SiON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY -2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1) COST
2085 030.32200 706 706
2086 030.32201 633 633
2087 030.32202 1,041 1,041
2008 030.32203 156 156
2069 030.32204 1,476 1.476
2090 030.32205 262 262
2091 030.32206 44 44
2092 030.32207 175 175
2093 030.32209 110 110
2094 030.32220 1,173 1.173
2095 030.32221 21 21
2096 030.32232 531 531
2097 030.32233 1oa 106
2098 030.32234 211 211
2099 030.32242 284 284
2100 030.32249 306 308
2101 030.32252 916 916
2102 03-0.32256 23 23
2103 030.32257 7,806 7,606
2104 030.32268 1,135 1,135
2105 030.32269 19 19
2106 030.32271 247 247
2107 030.32272 1,444 1,444
2108 030.32273 47,6:96 47,896
2109 030,32274 3,7'17 3,737
2110 030.32275 138 138
2111 03-0.32279 3-03 303
2112 030.3:2280 98 98
2113 030.32261 468 466
2114 OS0.32291 265 285
2115 030.32296 613 613
2116 030.32297 339 339
2.117 030.32299 222 222
2118 030.32302 22,250 22,250
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CY 1.016
DESCRIPTION OF COMPLETED PROJE:;CTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 213 FEET OF 4 INCH POLY MAIN AND 1 SERVICE AND RETIRE213 FEET OF 3 INCH STEEL MAIN AND 1 SERVlCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 INSTAll 25 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 25 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 192FEETOF2 INCH POLY MAIN AND RETIRE 14a FEET OF 2 INCH STEEL MAIN IN ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 101 FEETOF2 INCH POLY MAIN AND RETIRE 101 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL303FEET OF 4 INCH POLY MAIN AND RETIRE 303 FEET OF B INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 114 FEET 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 114 FEET OF 2 INCH STEEL MAIN ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALLS FEET OF 2 INCH POLY MAIN AND RETIRE 5 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 64 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 64 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.20:9 INSTALL 2 INCH LEAK CLAMP AND 2 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLILE B.209 INSTALL 122 FEET OF 4 INCH POLY MAIN AND RETIRE 122 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTAll 21 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE ANO RETIRE 21 FEET OF 2 INCH STEEL MAIN AND 1 SERVlCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLILE 8.209 REPLACE 1 SERVICE IN ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 21 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE AND RETIRE 21 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDAl>lCE WITH RAILROAD COMMISSION OF TEXAS RLILE 8.209 INSTALL 5 FEET OF2 INCH STEEL MAIN ANO RETIRE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 30 FEET OF 4 INCH STEEL MAIN AND RETIRE 30 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE OBSOLETE METER STATION IN ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 82 FEET OF 311-lCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD TEXACO STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 280 FEET OF 3 INCH POLY MAlN AND 4 SERVICES AND RETIRE 280 fEET OF 3 INCH STEEL MAIN AND 4 SERVICES lN ACCORDANCE Willi RA1LROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 4 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 867 FEET Of 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 667 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE Wini RAii.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 33 FEET OF 4 INCH POLY MAIN AND 74 FEET Of 2 INCH POLY MAIN ANO RETIRE 33 FEET OF 4 INCH STEEL MAIN AND 7 4 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL9895 FEET OF 2 INCH POLY MAIN AND206 SERVlCES ANO RETIRE 9832 FEET OF VARIOUS DIAMETER STEEL MAIN AND 206 SERVICES IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 166FEET OF2 INCH POLY MAIN AND 56 FEET OF 1.25 INCH POLY AND 3 SERVICES AND RETIRE 222 FEET OF 2 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 26 FEET OF 2 INCH POLY MAIN AND RETIRE 26 FEET OF 2 INCH STEEL MAlN AND REPLACE 2 SERVlCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLILE 8.209 INSTALL 325 FEET Of 2 INCH POLY MAIN AND RETIRE325 FEET OF 2 INCfl STEEL MAIN AND REPLACE 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.:209 INSTALL 7 FEET OF 3 INCH STEEL MAIN AND RETIRE 7 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 191 FEET OF POLY MAIN AND 5 SERVICES AND RETIRE 191 FEET OF STEEL MAIN AND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMilSSlON OF TEXAS RULE 8.209 INSTALL 58 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 68 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 6.209 tNSTALL 5810 FEET OF 2 INCH POLY MAIN AND 25 SERVICES AND RETIRE 5810 FEET OF VARIOUS SIZED STEEL MAIN AND 25 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLILE 8.209
WTX A.ddittons Pi;ig~S5-of9B
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
All-MIX
All-MIX
ALL-MIX
ALL· MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All- MD<
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL·MlX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF .PROJJ:CT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVIS!ON SYSTEM INTEGRITY MAY·201S
030 TEXAS DfVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSIDN SYSTEM INTEGRITY ' MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRiTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAs DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DJVISION SYSTEM INTEGRITY MAY -2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM 1NTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DJVIS!ON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2010
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201£
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAV-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSIDN SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISiON SYSTEM INTEGRITY M/\Y-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1J COST
2119 030.32.305 274 274
2120 030.32.342 25 25
2121 030.32343 277 277
2122 030.32345 158 158
2123 030.32347 291 291
2124 030.32351 305 305
2125 030.32352 2,160 2,160
2126 030.32353 64 64
2127 030.32361 1,222 1,222
2128 030.32'34l2 2.784 2,784
2129 030.32'34l3 233 233
2130 030.32364 364 364
2131 000.32366 3,474 a.474
2132 030.32367 3,896 3,896
2.133 030.32378 964 964
2134 030.32300 312 312
2135 030.32:381 350 350
2136 030.32382 420 420
2137 030.32384 97 97
2138 030.32385 2.753 2,753
2139 030.32386 92 92
2140 030.32.387 209 209
2141 030.32388 2,514 2,514
2142 030.32390 2,210 2,210
2143 030.32395 2,222. 2,222
2144 030.32396 2,934 2,934
2145 030.32397 2,293 2,293
2146 030.32398 2,559 2,559
2147 030,32400 2.979 2,979
2148 030.32401 2,627 2,627
2149 030.32403 2,805 2,805
2150 030.32404 2,498 2,498
2151 030.32405 2,617 2.617
2152 030.32406 2,914 2.914
2153 030.32407 179 179
2154 030.32408 1,728 1.728
2155 030.32410 3,544 3.544
2156 030.32411 2,922 2.922
2157 030.32412 2,629 2.1329
215B 000.32413 2,542 2.542
2159 0'30,32414 2,644 2,644
2160 030.32424 710 710
2161 030.32431 229 229
2162 030.32437 3,012 3,012
ATMOS ENERGY CORPOMTION, WESTTEXAS DIVISION
INTf Fl:IM COST RECOVERY AND RATE AOJUSYMENT REPORT PROJECT REPORT C.Y 2016
DESCRIPTION OF COMPLETED PROJEClS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTAU.26 FEET OF2 INCH POLY MAIN AND RETIRE26FEETOF2 INCH STEEL MAIN AND REPLACE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE 5 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 20 FEET OF 2 INCH STEEL MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 1 2 INCH STEEL WELDOVER IN ACCORDANCE WITH :RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALi. DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 76a FEET OF 2 INCH POLY MAIN IN ACCORDANCE WtTH RAILRAOD COMMISSION OF TEXAS RULE 8.209
INSTALL 121 FEETOF2 INOli POLY MAIN AND 1 SERVICE AND RETIRE 121 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 426 FEET OF 4 INCH POLY MAIN AND 1 SERVICE AND RETIRE 426 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE W!TH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 3 INCH STEEL MAIN AND 2 SERVICES ANO RETIRE 20 FEET OF STEEi. MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMJSSION OF TEXAS RULE 8.209 INSTALI. 384 FEET OF 4 INCH POLY MAIN AND 2 SERVICES AND RETIRE 384 FEET OF 6 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 353 FEET Of 4 INCH POLY MAIN AND 4 SERVICES AND RETIRE 363 FEET OF 4 INCH STEEL MAIN ANO 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 INSTALL 315 FEET OF 2 INCH POLY MAIN AND RETIRE300FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 13 FEET OF 3 INCH STEEL MAIN AND RETIRE 13 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 25 FEET OF 2 INCH POLY MAIN AND RETIRE 25 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL30 FEET OF 2 INCKPOLY MAIN AND 1 SERVICE AND RETIRE 30 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 INST ALL 5 FEET OF 2 INCH STEEL MAIN AND RETIRE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACEMENT DETAIL FOR AMARILLO IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPlACE 1 SERVlCE ~N ACCORDANCE WiTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 9 FEET OF 2 INCH STEEL MAIN AND RETIRE 9 FEET OF 2 INCH STEEL MAIN IN ACCOROA.l\ICE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL DEEPWEU. IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALI. DEEPWELL IN ACCORDANCE WITH RAILROAD COMMlSSJON OF TEXAS RULE 8.209 INSTALI. REPLACEMENT PEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF Tl'XAS RULE 8.209 INSTALL DEEPWELl IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL REPLACEMENT DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL OEEPWELL JN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8-209 INSTALL REPLACEMENT DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S.209 INSTALL DEEPWELL IN ACCORDANCE WITH RAILROAD COMM!SSION OF TEXAS RULE B.209 INSTALL DEEPWELl IN ACCORDANCE WITH RAILROAD COMMISSION OI= TEXAS :RULE B.209 INSTALL DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF IEXAS RULE B.209 RETIRE 1 3 INCH SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL DEEPWELL IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAs RULE 8.209 INSTALL DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE B.209 INSTALL DEEPWELL IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 INST AU. DEEPWELL IN ACCORDANCE WITH RAILROAD COMMJSSION OF TEXAS RULE 8.209 INSTALI. DEEPWELL ;N ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RULE 8.209 INSTALL DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 23 FEET OF 4 INCH STEEL MAIN AND 54 FEET Of 3 INCH POLY MAIN AND 1 SERVICE AND RETIRE 76 FEET OF 4 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE REGUlATOR IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
WTXAi:ldlti<ms P'age:S6of98
CUSTOMERS BENEFITED
ALL· MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALl..-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL- MIX
All.-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All· MIX
ALL-MIX
DATE PLACED I" GAS PLANTIN
LOCATION PURPOSE DF PROJECT SERViCE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS !JIVISJON SYSTEM INTEGRITY MAY-2016
030 TEXAS OIVISJON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY SEPTEMBER- 2016
000 TEXAS DIVISION SYSTEM ~NTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGR1TY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
aao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2010
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DMSJON SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVISION sYSTEM INTEGRITY MAY-2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION sYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYS1EM INTEGRITY MAY·2016
030 TEXAS DIVISION SYS1EM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lN1EGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM l~'TEGRfJY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE NO. PROJECT NUMBER COST!11
2163 030.32438 2,700
2164 030.32439 2.383
2165 030,3244:9 253
2166 030_32450 461
2167 030.32451 63
2.168 030.32453 384
2169 030.32454 72
2170 030.32474 844
2171 030.32478 193
2172 030.32479 611
2173 030.32485 1,695
2174 030.32466 828
2175 030.32469 141
2176 030.32490 917
2177 030.32492 460
2178 030.32493 241
2179 030.32494 147
2180 030,32495 167
2181 030.32496 185
21a2 030.32497 330
218'3 030.32499 75
2184 030.'32500 84
2165 030.32501 1"2
2100 030.32502 146
2187 030.32511 149
2188 030.32513 1,199
2189 030.325"'!4 440
2190 030.32515 645
2191 030.3251'6 171
2.,92. 030.32517 424
2193 030.32518 152
2194 030.32519 14 :-·
2195 030.32520 66
2196 030.32521 571
2197 030.32525 BB
2196 030.32529 9
2199 030.32544 677
2200 030.32552 200
2201 030.32553 10,264
2202 030.32555 319
2203 03Q.32.556' 270
2204 030.32557 362
ALLOCATED COST
2,700
2,383
253
461
83
38~
n
B44
193
611
1,B95
828
141
917
460
241
147
157
185
330
75
84
192
146
149
1,199
440
645
171
424
152
14
66
571
""
ATMOS ENERGY CORPOltATION, WESTTEXAS DIVISION INTERIM COST RECOVERY ANO HATE ADJUSTMENT REPORT
PROJECT REPORT CV W16
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016121 BENEFITED
INSTALL DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 42 FEET OF 2 INCH POLY MAIN ANO 1 SER\llCE AND RETIRE 42 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WlTH RAIL.ROAD COMMISS~ON OF TEXAS RULE 8_209 AL!.-MIX INSTALL 53 FEETOF2 INCH POLY MAIN AND RETIRE 44 FEETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-Mtx RETIRE SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX INSTALL37 FEET OF 4 INCH POLY MAIN AND RETIRE 37 FEETOF4 INCH STEEL MAIN iN ACCORDANCE WITH RAILROAD COMMISSiONOFTEXAS RULE B.209 ALL-MIX INST ALL 20 FEET OF 2 !NCH POLY MAIN AND RETIRE 20 FE.ET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 112 FEET OF 4 INCH POLY MAIN AND RETIRE 112 FEET OF 5 AND 6 INCH STEEL MAON IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REROUTE 2 INCfl STEEL AND POLY MAIN DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 145 FEET OF 3 INCH STEEL MAlN DUE TO PUBLIC IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INST ALL 375 FEET OF 4 INCH POLY MAIN AND RETIRE 6 INCH STEEL MAIN tN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WJTH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALt.-MIX INSTALL 17 FEET OF 4 INCH POLY MAIN AND RETIRE 17 FEET OF 7 INCH STEEL MAIN IN ACCORDANCE WITH RAtlROAD COMMISSION OF TE:.'<A:S RULE 8_209 ALL- MIX INSTALL 101 FEET OF 4 INCH POLY MAIN AND RETIRE 101 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 6 FEET OF 2 INCH POLY MAIN AND RE?LACE 2 INCH GATE VALVE IN ACCORDANCE WITH RAILROAD COMMISSION OF n;XAS RULE a.209 ALL-MIX .REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MlX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 5 FEET Of 4 INCH STEEL MAIN AND RETIRE6 FEET OF4 INCH STEEL MAIN tN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS .RULE B.209 ALL-MIX INST ALL 5 FEET OF 4 INCH STEEL MAIN AND RETIRE 5 FEET OF 4 INCH STEEL MAIN tN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SER\llCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 6 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 6 FEET OF 2 INCH PLASTIC MAIN AND 1 SERVICE IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 6 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 2 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 28 FEET OF 4 INCH STEEL MAIN AND RETIRE 28 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 1 FEET OF 6 INCH STEEL MAIN AND REPLACE 7 FEET OF 6JNCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX RETIRE 79 FEET OF 2 lNCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUt.E 8_209 /\LL-MIX INSTALL 114 FEET OF 2 INCH POLY MAIN AND RETIRE 114 FEET OF 2 lNCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX INSTALL 76 FEET Of 2 INCH POLY MAIN AND RETIRE 76 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 /\LL-MIX REPl.ACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INST ALL 2 2 INCH ENCIRCLEMENTS tN ACCORDANCE WITH
9 RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
677
200
10,284
319
270
362
INSTALL 195 FEET OF 2 INCH POLY MAIN AND 6 SERVICES ANO RETIRE 195 FEET OF 2 INCH STEEL MAIN AND 6 SERVICES lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALt.1 2 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL3500 FEET OF2 INCH POLY MAIN AND 20SERVICES AND RETIRE 3500 FEET OF 2 INCH PLASTIC MAIN AND 20 SERVICf;S IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE B.209 INSTALL 15FEET OF .75 INCH POLY AND'RETiRE 15 FEET OF 4 INCH STEEL MAIN iN ACCORDANCE WITH RAILROAD COMMISSION OF' TEXAS RULE 8.209
INSTALL 13FEET OF 4 INCH POLY MAIN AND RETIRE 13 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITli RAil.ROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 8 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE AND RETtRE 8 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX Additions Page 57 of98.
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM lNTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DtVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-:m16
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSJON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2010
030 TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DtVtStON SYSTEM INTEGRITY MAY-2016
030 TEXAS DMStON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY·2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
0:30 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER -2016
030 TEXAS DMSION SYSTEM tNTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1) cosr
2205 030.32565 200 200
2206 030.32566 745 745
2207 030.32569 250 250
2208 000.3l573 3,409 3,409
2209 030.32577 159 159
2210 030.32579 110 110
2211 030.32580 199 199
2212 030.32582 1.486 1,486
2213 030.32590 133 133
2214 030.3:2591 400 400
2216 030.32592 48 4•
2216 030_32602 2,332 2,332
2217 030.32614 471 471
2218 030.32615 168 168
2219 030.32618 322 322
2220 030.32619 61 61
2221 000.32620 214 214
2222 030.32522 554 554
2223 OJ0.32631 15,863 15,863
2224 030.32637 112 112
2225 030.32638 10,403 10,403
2226 030.32642 601 601
2227 030.32644 27 27
2220 030.32645 2,657 2.657
2229 030.32649 3,435 3.435
2230 030.32670 108 10B
2231 030.J267B 652 652
2232 030.32600 49 49
2233 030.32684 1,466 1,466
2234 030.32688 419 419
2235 030.32689 224 224
2236 030.32690 53 53
2237 030.32691 405 405
;223a 030.32892 140 148
2239 030.32894 154 154
2240 030_32696 2,263 2.253
2241 030.32705 3,784 3,764
ATMOS ENERGY CORPORATION, WEST TEXAS DIV!SION INTERIM COST 1n:covrnv AND RATE ADJUSTMENT REPORT
PROJECT RE.PORT CV 2016
DESCRIPTION OF COMPLETEIJ PROJECTS OEDlCAIEO TO PUBLIC USE IN CALENDAR VEAR 2016 (2l
INSTALL 21 FEET OF 2 INCH STEEL MAIN AND RETIRE 21 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WIT1" RAILROAD COMMISSION OF TEXAS RUl.E 8.209 INSTALL 15FEET OF2 INCH STEEL MAIN AND RETIRE 15 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WIT1" RAILROAD COMMISSION OF TEXAS RULE 8,209 REPlACE 1 SERVICE IN ACCORDANCE WffH RAlLROAO COMMISSION OF TEXAS RULE 8.209 INSTAl-L 762 FEET Of 4 INCH POLY MAIN AND RETIRE 762 FEET OF 6 INCH STEEL MAIN AND REPlACE 1 SERVICE IN ACCORDANCE WIIB RAILROAD COMMISSION OF TEXAS RUl-E 8.209 INSTALL 110 FEET OF 2 INCH POLY MAIN AND RETIRE 110 FEET Of 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1287 F~l" OI= 3 INCH STEEL MA1N IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 40 FEET OF 3 INCH POl-Y MAIN AND 1 SERVICE AND RETIRE 40 FEET OF 3 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WIIB RAILROAD COMMISSION OF TEXAS RULE 9.209 REBUILD CPR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 27 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE ANO RETIRE 27 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RULE 8.2.09 INST ALL 6 FEET Of 6 INCH POLY MAIN AND RETIRE 6FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 355 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE llll1 FEET OF 6 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALl-17 FEET OF 4 INCH POLY MAIN AND 1 SERVICE AND RETIRE 17 FEET OF 4 INCH STEEi- MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPlACE 1 SERVICE IN ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 74 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 63 FEET OF 2 INCH AND 11 FEET OF 3 INCH STEEL MAIN AND 1 SERVlCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2.09 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXA.S RULE 8.209 RETIRE TWO SERVICES IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 7602 FEET OF 2 AND 4 INCH POLY MAIN AND RETIRE 7602 FEET OF 2 AND 4 INCH STEEL MAIN AND REPlACE 112 SERVICES iN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 2 INCH LEAK CLAMP AND 2 INCH WELDOVER IN ACCORDANCE Wrn-1 RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 16867 FEET OF 2 INCH POLY MAIN AND RETIRE 35133 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 INSTALL BB FEET OF 2 INCH STEEi- MAIN AND RETIRE 96FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl-E B.209 RETIRE 1 SERVICE IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 607 FEET OF 2 INCH POLY MAIN AND 12 SERVICES AND RETIRE 607 FEET OF 2 INCH STEEL MAIN AND 12 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 775 FEET Of 2 INCH POLY MAIN AND 11 SERVICES AND RETIRE 775 FEET Of 2 INCH STEEL MAIN AND 11 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 INSTALL 2 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL253 FEET OF 2 INCH POLYMAlN AND RETIRE 274 FEET OF 2 INCH STEEL MAIN AND REPLACE 6 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 60 FEET OF 2 INCH POLY MAIN AND RETmE BO FEET OF 2 INCH STCEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 16 FEET OF 3 INCH STEEL MAIN AND RETIRE 16 FEET OF 3 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 44 FEET OF 2 INCH STEEL MAIN AND RETIRE 44 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMIBSJONOFTEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RU!.E B.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALi- 136 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 136 FEET OF 2 INCH PLASTIC MAIN AND 1 SERVICE IN ACCORDANCE Willi RAILROAD COMMISSJON OF TEXAS RULE 9.209 INSTALL 24 FEET OF 2 INCH STCEL MAIN AND RETIRE 24 FEET OF STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209
INSTALL 261 FEET OF 4 INCH POLY MAIN AND RETIRE 261 FEET OF DIFFERENT SIZED STEEL AND POL V MAIN IN ACCORDANCE Willi RAILROAD COMMJSSION OF TEXAS RULE B.209 INST ALL 642 FEET OF 2 INCH POLY MAIN AND 14 SERVICES AND RETIRE 971 FEET OF 2 INCH STEEL MAIN AND 14 SERVICES IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX.Addltiom;. Page 5B of98
CUSTOMERS BENEFITED
AL!.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALl--MIX
ALL-MIX
ALL· MIX
All-MIX
ALL-MIX
All-MIX
ALL-.MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL.- MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
uA.1 E PLACED IN GAS PLANT IN
LOCATION PURPOSE Of PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTCM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTCM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRJTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY~2016
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTCM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201S
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISJON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM fNTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED No. PROJECT NUMBER COST(1f COST
2242 030.32708 63 63
2243 030.32709 127 127
2244 000.32721 229 229
2245 030.32745 5.966 5,968
2246 030.32746 273 273
2247 030.32749 224 224
2248 030.32751 101 101
2249 o:m_a21s3 49 49
2250 030.32758 365 365
2251 030.32765 455 456
22:52 030.32.774 61 61
2253 030.32776 200 200
2254 030.32778 2BB 288
2255 030.32783 566 566
2256 030.32766 222 222
2257 030.32791 45 45
2256 030.32792 45 ~5
2259 O'l0.32793 234 234
2260 030.32794 57 57
2261 030.32795 103 103
2262 0:30.327:99 2.493 2,493
226.'l 030.32801 366 366
2264 030.32603 932 932
2265 030.32804 985 985
2266 030.32805 a,624 3,624
2267 030.32806 57 57
226B 000.32807 120 120
2269 030.32810 97 97
2270 030.32816 921 921
2271 030.32833 161 161
2272 030_32834 125 125
2273 030.32839 228 226
2274 030.32841 160 160
2275 030_32a4B '2,976 2,978
2276 030.32849 709 709
2.277 030.32850 296 296
2278 030,32851 277 277
2279 030.32856 145 145
ATMOS ENERGY CORPORATION, WEST TEXAS DJVl$10N JNTERIM COST RECOVER'V' AND AAl"E ADJUSTMENT REPORT
PROJECT REPORT CT 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR2016 (2)
REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTAUL 12 INCHWELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTAl..l. 800 FEET OF 4 INCH POLY MAIN AND 23 SERVICES AND RETIRE 800 FEET OF 4 INCH STEEL MAIN AND 23 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 7 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 5 FEET OF 2 INCH STEEL AND 2 FEET Of 2 INCH PLASTIC MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WtTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 7B FEET Of 2 INCK POLY MAIN AND RETIRE 78 FEET OF 2 INCH sTEE!. MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 24 FEET OF 3 INCli STEEL AND 2 SERVICES AND RETIRE 24 FEET OF 3 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 900 FEET OF 2 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RU!.E 8,209 REPLACE 1 ROOTS METER IN ACCORDANCE Willi RAILROAD COMMISSlONOFTEXAS RULE 8.209 INSTALL 6 FEET OF 3 INCH STEEL MAIN AND 1 SERVICES ANO RETIRE 6 FEET OF 3 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 76 FEET OF 2 INCH POLY MAIN AND 1 SERVICE ANO RETIRE B7 FEET OF 2 INCH STEEL MAIN ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 6.200 INSTALL 1 2 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION DF TEXAS RULE 8.209 INSTALL34 FEET OF 2 INCH POLY MAIN AND RETIRE 34 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 15 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.208 INST ALL 555 FEET OF 2 INCH POLY MAIN AND 10 SERVICES AND RETIRE 565 FEET OF2 INCH STEEL MAIN AND 10 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 32 FEET OF 4 INCH POLY MAIN AND 1 SERVICE AND RETIRE 32 FEET OF 3 INCH STEEL MAIN ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD METER IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAs RULE 8.209 INSTALL 370 FEET OF 4 INCH POLY ANO 135 FEET OF 2 INCH POLY MAIN AND RETIRE370FEET0f 3 INCH STEEL AND 135 FEET OF 2 INCH STEEL MAIN AND REPLACE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INST ALL 584 FEET OF 4 INCH POLY MAIN AND 3 SERVICES AND RETIRE 5~7 FEET OF 3 INCH STEEL MAIN AND 37 FEETOF4 INCH POLY MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSiON OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 16 FEET OF 2 INCH STEEL MAIN AND RETIRE 16 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.200 INSTALL 6 FEET OF 3 INCH POLY MAIN AND RETIRE 8 FEET OF PLAST!C MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 17 FEET OF 2 INCH STEEL MA!N AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 6.200 INSTAUL 65 FEET OF 2 INCH POLY MAIN ANO RETIRE 65 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVlCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 INSTAUL 5 FEET OF 3 INCfl STEEL MAIN AND 1 SERVICE ANO RETIRE 5 FEET OF 3 INCH STEEL AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 124 FEET OF 4 INCHAND676 FEETOF2 INCH POLY MAIN AND RETIRE 802 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE
-WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 104 FEET OF 2 INCH POLY MAIN AND 2 SEIWICES AND RETIRE 104 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 fNSTALL 44 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES AND RETIRE 44 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE a.209 INSTALL 103 FEET OF 2 INCH POLY MAIN ANO 1 SERVICE AND RETIRE 103 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
WlXAddtt[ah$ ll';mg-e59.of9B
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL· MIX
ALL· MIX
ALL-MIX
ALL-MIX
All- MIX
ALL-MIX
ALL-MIX
All-MIX
AUL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL· MIX
All-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL- MIX
AUL-MIX
AUL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
All-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
Al..l.-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM lNTEGRffY MAV-2016
030 TEXAS DJVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRtlY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRtlY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITI' MAY-2016
030 TEXAS Dtv!SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-20115
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
OSO TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATEiO NO. PROJECT NUMllER COST(1) COST
2200 030.32859 639 639
22.81 030.32860 125 125
2282 030.32662 39 39
22B3 030.32669 170 170
2284 030.32670 132 132
2285 030.32873 409 409
2266 030.32680 272 272
2287 030.32085 37 37
2266 030.32689 69 69
2289 030.32690 764 764
2290 030.32692 701 701
2291 030.32893 429 429
2292 000.32896 450 450
2293 000.32923 73 73
2294 030.32924 718 778
2295 030.32925 116 115
2296 030.32929 719 719
2297 030.32930 13 13
2296 030.32931 36 36
2299 030.32932 21 21
2300 030.32933 209 209
2301 030.32934 68 68
2302 030.32935 666 666
2303 030.32937 1,013 1,013
2304 030.32943 75 75
2305 030.32952 1,928 1,928
2306 030.32953 3,766 3,766
2307 030.32955 93 93
2308 030,32958 2,040 2,040
2309 030.32961 191 191
2310 030.32962 181 181
2311 030.329621 42 42
2312 030.32968 605 605
231a 030.32971 4,924 4.924
2314 030.32975 12 12
2315 030.32984 369 369
2316 030.32985 3.163 3,163
2317 030.32967 663 683
2316 030.32966 25 25
2319 030.32993 81.586 81,586
2320 030.32994 99 99
2321 030.33000 282 282
ATMOS ENERGY CORPORATION, WESTTf:>Wi OIVISION !NTERIM COST RECOVERY AND RAT~ ADJUSTMENT REP'ORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2.016 (2]
INSTALL 313 FEET OF 2 INCH POLY MAIN ANO 4 SERVICES AND RETIRE 1:.157 FEET OF 6 INCH /\ND 352 FEET OF 4 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 13 FEET OF 2 INCH POLY MAIN AND RETIRE 13 FEET OF2 lNCH STEEL MAIN IN ACCORDANCE W!TH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE li'l ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 2 INCH ENClRCLEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF 1EXAS RULE 6.209 INST ALL 1 8 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INST ALL 2 INCH WELDOVER ON 2 INCH DRESSER TO REPAIR LEAK ON PROTECTED STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 4 !NCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 2 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 76 FEET OF 2 INCH POLY MAIN ANO RETIRE 422 FEET Df 2 INCll STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 INCH WEL!JOVER IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RULE 8.200 RETIRE CPR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE CPR STATION IN ACCORDANCE WITfl RAILROAD COMMJSSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAO COMMISSION OF TEXAS RULE 8.209 INSTALL 600 FEET OF21NCH POLY MAIN AND 5 SERVICES AND RETiRE 757 FEET OF 1 AND 2 INCH STEEL MAIN AND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 16 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET Of 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 3252 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE REGULATOR IN ACCORDANCE WITH RAILROAD COMMISSION Of TCXAS RULE 8.209 RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF.TEXAS RULE 8.209 INST ALL 224 FEET OF 2 INCH POLY MAIN /\ND 7 SERVICES AND RETIRE 224 FEET DF STEEL MAIN AND 7 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REFlACE 8 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 41600 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2"9 INSTALL 415 FEET OF 2 INCH POLY MAIN AND 11 SERVICES AND RETIRE 415 FEET OF2 INCH STEEL MAIN /\ND11 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUIE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 lOWER /\ND REPLACE 500 FEET OF 4 INCH STEEi. MAIN IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 176 FEET OF 2 INCHPOLY MAIN AND RETIRE 176 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 -75 INCH POLY SERVICE AND RETIRE 11 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 305FEET OF 4 INCH POLY MAIN/\ND 3SERVICES AND RETIRE 305 FEET OF 4 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 1 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 250 FEET OF 2 iNCH POLY MAIN AND 1 SERVICE AND RETIRE 250 FEET Of 3 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 5300 FEETOF2 INCH POLY MAIN /\ND RETIRE5300 FEET OF 2 fNCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMJSSION OF TEXAS RULE 8.209 INSTALL 291 FEET OF 2 INCH POLY MAIN AND 5 SERVICES ANO RETIRE 291 FEET OF 2 INCH STEEL MAIN AND 6 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 9FEET OF2 INCH STEEL MAIN ANDRETiRE 9 FEET CF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TCXAS RULE 8.209 RETIRE 19449 FEET DF VARIOUS DIAMETER STEEL PIPE AND INSTALL 15513 FEET OF 2 INGH POLY MAIN AND REPLACE 391 SERVICES IN ACCORDANC!O WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 1 SERVICE AND RETIRE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 45 FEET OF 2 INCH POLY MAIN AND RETIRE 45 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WIX Additions Page-60 of9B
CUSTOMERS llENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
All-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
A!.L-MIX
ALL-MIX
All.-MIX
ALL-MIX
ALL-MIX
All· MIX
ALL-MIX
ALL-MIX
ALL-MJX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISJON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2<l16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SVSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016 I 030 TEXAS DIVISION SYS1EM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
020 TEXAS DIVISION SYSTOM INTEGRllY MAY-2016
030 TEXAS DIV!SlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
! 030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlViSION SYSTEM !NTEGRlTY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2"16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST!1) COST
2322 030.33004 1,371 1,371
2323 030.33005 540 540
2324 030,33000 3B 38
2325 030.33037 26 26
2326 030.33044 141 141
2327 030,33051 1,288 1,288
2::328 030.33056 261 261
2329 030.33058 292 292
2330 030.33080 12.786 12,766
2331 030.33082 114 114
2332 030.33063 5'3 56
2333 030.33064 139 139
2334 030.33065 25 25
2335 030.33066 40 40
23'6 030.330159 158 168
2337 030.33074 129 129
2338 030.33081 340 340
2339 030.33082 35,543 35.543
2340 030.33087 1,194 1.1•~
2341 030.33111 316 315
2342 030.33112 179 179
2343 030.33113 263 263
2344 030.33118 163 163
2345 030.33128 267 267
2346 030.33133 1,176 1.176
2347 030.33155 143 143
2348 030.33160 1.512 1.512
2349 030.33162 24,239 24,239
2350 030.33163 238 238
2351 030.33173 12 12
2352 030.33183 129 129
2353 030.33184 44 44
2364 030.33187 321 321
2355 030.33188 1,452 1.452
2356 030.33195 144 144
2357 030.33198 313 313
2358 030.33206 2,005 2.005
2359 030.33207 598 598
ATMO$ ENER6YCDRPOAATION, WEST TEXAS OIVISJQN INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJEcr Rf PORT Ci 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 j2)
INST ALL 159 FEET OF 6 INCH POLY MAIN ANO RETIRE 159 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL ONE 2 INCH WELDOVER ALONG TUCSON ROAD IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INST ALL 1 2 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 RETIRE 180 FEET OF 4 INCH AND 184 FEET OF 2 INCH POLY MAIN AND 1 SERVICE IN ACCORDANCEW!TH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 28 FEET OF 5 INCH STEEL MAIN AND 2 SERVICES AND RETIRE 28 FEET DF 6 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B,209 RETIRE 15143 FEET OF 2 INCH PLASTlC MA~N AND 83 FEET OF 2 INCH POLY MAIN IN ACCORDANC:E wm-l RAILROAD COMMISSION OF TEXAS :RULE 8.209
INSTALL 45 FEET Of 2 INCH STEEL MAIN AND 1 SERVICE AND RETIRE 54 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 6.209 INSTALL 17768 FEET Of 2 INCH PDLY MAIN AND RETIRE 17768 FEET Of 2 INCH Pl-ASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 RETIRE 326 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITI-l RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 27 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 8.209 INSTALL 5 FEET OF POLY MAIN AND RETIRE 5 FEET OF 2 INCH Pl-AsTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION oF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH Pl..ASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL ONE 2 INCH WELDOVER STEEL ALONG DAK ROAD IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 3 INCH WELDOVER ON 3 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST Al.L 2 4 INCH WELOOVERS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL6500 FEET OF 2 INCH POLY MAIN AND 115 SERVICES AND RETIRE 6500 FEET OF 2 INCH STEEL MAIN AND 115 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 288FEET DF 4 INCH POLY MAIN AND RETIRE 288 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 13 FEET OF 3 INCH STEEL MAIN AND 1 SERVICE AND RETIRE 12 FEET OF 3 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 6 FEET OF STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RllLE 8.209 RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 36 FEET OF 6 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 154 FEET Of 2 INCH POLY MAIN AND 3 SERVICES ANO RETIRE 154 FEETOF2 INCH STEEL MAIN AND 3sERVICES IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 6.209
INSTALL 1055 FEET OF 4 INCH AND 7331 FEET OF 2 INCH POLY MAIN AND 55 SERVICES /\ND RETIRE 8709 FEET OF VARIOUS SIZE STEEL MAIN AND 55 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL234 FEEToF 2 INCH POLY MAIN AND RETIRE 209 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF H'XAS RUl-E 8,209 RETIRE 1 SERVICE DUE TO IN ACCCORDANCEW!TH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL209 FEET OF 2 INCH POLY MAIN AND RETIRE 209 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RlJLE 8.209 INSTALL 10FEET OF2 INCH POLY MAIN AND RETIRE 10 FEET DF2 INCH PLASTIC MAIN IN ACCORDANCE wrrH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 206 FEET OF 4 INCH POLY MAIN AND RETIRE 206 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RllLE 8.209 INSTALL221 FEET OF 4 INCHSTEEL MAIN AND RETIRE434 FEET Of 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMtSSION OF TEXAS RULE 8.209 INSTALL 8 FEET OF 2 INCH POLY MAIN AND RETIRE 8 FEET OF 2 INCH Pl-ASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF lEXAS :RULE 8.209 REPLACE 20 FEET OF 4 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 300 FEET OF 2 INCH POLY MAIN ANO 2 SERVICES AND RETIRE 290 FEET OF 3 INCH STEEL MAIN AND 10 FEET Of 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8-209 INSTALL294FEET OF2 INCH POLY MAIN AND RETIRE65 FEET IF 1.25 INCH STEEL MAIN ANO REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
WIX Additions Pagl!!:61 of518
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
Al.L-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
/\LL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
Al.L-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL.-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
DATE Pl..ACED IN GAS Pl..ANTIN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ~2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION sYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-20115
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMS!ON SYSTEM INTEGRITY MAY-2016
030 lEXAS DMSION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VJSION SYSTEM INTEORITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 Tl=XAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2010
030 TEXAS DIVISION SYSTEM lNTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM !NTEGRln' MAY-2016
030 TEXAS DIVlSIO'I SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRllY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST[1) COST
2360 030.33211 1,917 1.917
2361 030.33213 71 71
2362 030.33216 1,020 1,020
2363 030.33230 2.360 2,360
2364 030.33232 11,066 11,066
2365 030.33235 45,612 45,612.
2366 030.33237 629 629
2367 030.33241 675 675
2368 030.33243 2,206 2,206
2369 030.33268 14 14
2370 030.33270 696 696
2371 030.33273 560 560
2372 03-0.33275 430 430
2373 030.33276 97 97
2374 030.33277 297 297
2375 030.33280 605 605
2376 030.33281 511 511
2377 030.332.83 475 475
2378 030.33290 219 219
2379 030.33291 483 483
2300 030.33292 281 261
2381 mm.33293 201 201
2382 030.33296 658 658
2383 030.33299 4.280 4,280
2384 030.33302 144 144
2385 030.33310 3,306 3,306
23B6 030,3'3311 784 764
2387 030.33312 171 171
2388 030.33313 233 233
2389 030.33314 1,848 1,848
2390 030.33317 1,037 1,037
2391 030.33322 437 437
2392 030.33325 199 199
2393 o:m.33329 172 172
2394 030.33346 1,012 1.012
2395 030.33354 109 109
2396 030.33355 823 823
2397 030.33356 506 506
2398 030.33357 40 40
23')9 030.33359 44 44
2400 030.33360 940 940
AtMO.S ENERGY CORPOMTION, WE:S.T TEXAS DIVlSIOlll JNTERIM: COST RECOVERY AND RATE ADJVSl'MENT REPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 [2)
INSTALL 340 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 647 FEET OF 1 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVlCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 46 FEET OF 2 INCH POLY MAJN AND 1 SERVICE AND RETIRE 46 FEET OF 3 INCH STEEL MAIN AND 1 SERV!CE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.:209 INSTALL 1460FEET OF2 INCH POLY MAlNAND RETIRE aeo FEET OF 1 INCH STEEL AND 1080 FEET OF 1.25 AND 2 INCH PLASTIC MAIN AND REPLACE 10 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE e.209 INSTAUL 4000fEET OF6 INCH POLY MAJNANO RETIRE4000 FEET OF 10 INCH STEEL MAIN IN ACCORDANCE WrTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 7949 FEET OF 6 INCH AND 3232 FEET OF 4 INCH POLY MAJN AND 27 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 179 FEET OF 2 INCH POLY MAIN AND 5 SERVICES AND RETIRE 179 FEET OF 2 INCH STEEL MAIN AND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 23 FEET OF 6 INCK STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 75 FEET OF 4 INCH POLY MAIN AND RETIRE 75 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAJLROAD COMMISSION Of TEXAS RULE B.209 RETIRE 51 FEET OF 1 INCH STEEL SERVICE IN ACCORDANCE wm1 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 154 FEET OF 4 INCH POLY MAIN AND 5 SERVICES AND RETIRE 162 FEET OF 3 INCH STEEl MAIN AND o SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 5 FEET OF 6 INCH STEEL MAlN IN ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 40 FEET OF 2 INCH POLY MAJN AND RETIRE 40 fEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 .75 INCH POLY SERVICE AND RETIRE 1 STEEL SERVICE IN ACCORDANCIO WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 103 FEET OF 4 INCHAN011 FEET OF 3 INCH POLY MAIN ANO 4 SERVICES AND RETIRE 103 FEET OF 4 INCH STEEL MAIN AN!l 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6,209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 32 FEET OF 4 INCH POLY MAIN AN02 SERVICES AND Rl'TIRE 32 FEET OF 4 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 10 FEET OF 2 INCH POLY MAIN AND RETIRE 10 FEET OF 2 INCH PLASTIC MAIN !N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 140 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6809 FEETOF2 INCH POLY MAIN AND RETIRE 23849 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE e.:109 REPLACE STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 20 FEET OF 4 INCH POLY MAIN AND RETIRE 12 FEET OF 4 INCH POLY MAIN IN ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RULE 8.209 RELOCATE901 FEETOFS INCHPOLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 S RELOCATE 3 ~NCH UNE lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 12 FEET OF POLY MAIN AND2 SERVICES AND RETIRE 12 FEET OF 4 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 12 INCH ENCIRCLEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 378 FEET OF 1.25 INCH POLY MAIN AND RETIRE 378 FEET OF 2 lNCH PiASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE ~N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 15 FEET OF 4 INCH STEEL MAIN AND 61 FEET OF 3 INCH POLY MAIN AND RETIRE 75 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISS!ON OF TEXAS RUlE 8.209 REPLACE 14 FEET OF 2 INCH POLY MAJN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S.2.09 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 412 FEET CF 2 INCH POLY MAIN AND RETIRE 412 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF T~AS RUl..E. 8.209
WTX Additions Page 62 of98
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL- MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION S'(STEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ~2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INlEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM IMPROVEMENTS MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVJStON PUBLIC IMPROVEMENTS MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY·2016
030 TEXAS DIVlSIDN SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1) COST
2401 030.33362 76 76
2402 030.33363 318 318
2403 030.33366 ;28,953 28,953
2404 030_33366 2,643 2,643
2405 030.33376 1,028 1,028
2406 030.33377 1.oa2 1,082
2407 030.33378 449 449
2408 030.33379 373 373
2409 030,33380 255 255
2410 030.33394 100 159
2411 030.33395 425 425
2412 030.33396 2e2 262
2413 030.33397 223 223
2414 030.33399 282 282
2415 030.33403 251 261
2416 030.33406 631 631
2417 030.33408 2,972 2,.972
2416 030.33415 634 634
2419 030.33416 1,268 1,268
2420 030.3:3419 76 76
2421 030.33420 350 350
2422 030.33432 168 168
2423 OJ0_33436 167 167
2424 030.33439 1,311 1,311
2425 030.33441 11 11
2426 030.33442 469 469
2427 030.33443 522 522
2428 030.33446 1,064 1.064
2429 030.33447 564 564
2430 030.33452 393 393
2431 030,3345:3 B25 825
2432 030.33468 2,690 2.69-0
2433 030,3:3472 104 104
2434 030.33473 661 661
2435 030.33475 153 153
2436 030.33478 692 692
2437 030.33480 262 262
2438 030,33483 54 54
2439 030.33485 169 169
ATMOS ENE.RGV CORPORATION, WJ:STTEXAS DlVIS!ON INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT RE.PO!n' CV ao16
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
REPLACE 1 SERVICE IN ACCORDANCE WffH RAILROAD COMMISSION OF TEXl\S RULE 8.21l9 INSTALL Oil FEET OF 3 INCH STEEL MAIN AND RETIRE 30 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXl\S RULE 8.209 lNSTALL 2250 FEET OF 8 INCH AND 2450 FEET OF 6 INCH AND 310 FEET OF 4 INCH POLY MAIN AND RETIRE 12e0 FEET OF 8 INCH AND 2755 FEET OF 6 INCH AND 22 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RU!.E 8.209 INSTALL4877 FEET OF 2 INCH POLY MAIN AND RETIRE 635 FEET OF 1.25 INCH STEEL MAIN IN ACCORDANCE WffH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL475FEET DF2 INCHAND 55 FEET OF 1.25 INCH POLY MAlN AND 2 SERV!CES AND RETIRE B45 FEET OF 2 !NCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXl\S RULE 8.209 REBUILD AND REPLACE CPR STATION IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXl\S RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXl\S RULE 8.209 RETIRE 155 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL e FEET Of 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 6 FEET OF 2 INCH PLASTIC MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROA!l COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE 5 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXl\S RULE 8.209 RETIRE 5 FEET OF 3 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALLS FEET OF POLY MAIN AND 1 SERVICE AND RETIRE 5 FEET OF 2 INCH PLASTIC MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTAL.l.. 5 FE.ET OF 2 INCH POLY MAIN AND 1 SERV~CE AND RETIRE 5 FEET OF 2 INCH PLASTIC AND 1 SERVICE IN ACCORDANCE WITH RAil.ROA[) COMMISSION Of TEXAS RULE B.;209 REPLACE 20 FEET OF 2 INCH STEEL MAIN ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXl\S RULE 8.209 REPl.ACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 6.209 INSTALL 37 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE AND RETIRE 37 FEET OF 2 INCH STEU MAIN A'lO 1 SERVICE IN ACCORDANCE WrTH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 371 FEET OF 4 INCH POLY MAIN ANO 4 SERVICES AND RETIRE 371 FEET OF 3 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 13 FEETOF4 INCH POLY MA!NAN!l1 SERVICE ANO RETIRE 13 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL ONE 16 INCH WELDOVER ALONG AMARILLO BOULEVARD IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE e.209 REPLACE 1 SERVICE IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD METER SETTING IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 12 FEET OF 2 INCH POLY MAlN AND RETIRE 12 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 REBUILD REGULATOR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET OF 2 INCH POLY MAIN ANO RETIRE B FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RA!LROAO COMM~SSION OF TEXAS RULE 8.209 REPLACE 5 FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 17 FEET OF 4 INCH POLY MAIN AND RETIRE 17 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF Tl'XAS RULE 8.209 REBUILD REGULATOR STATION IN ACCORDANCE WtTH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXl\S RULE 8.209 REBUILD REGULATOR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXl\S RULE 8.209 INSTAll24B4 FEET OF 2 INCH POLY MAIN ANO RETIRE 2464FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAIU<OAO COMMISSION OF TEXl\S RULE B.209
INSTALL 140 FEET OF 2 INCH AND 69 FEET OF 4 INCH POLY MAIN AND 2 SERVICES AND RETIRE 243 FEET OF 2 INCH AND 69 FEET OF 4 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.21l9 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXl\S RULE B.209
INST ALL225 FEET OF 2 INCH POLY MAIN AND 6 SERVICES AND RETIRE 225 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS :RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 363 FEET OF 2 INCH POLY MAIN AND RETIRE 353 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 8.209 INSTALL 5 FEET OF 2 INCi-i POLY ANO RETIRE 5 FEET OF 2 INCH STEEL IN ACCORDANCE WITl-I RAILROAD COMMISSION OF TEXAS RULE8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E B.209 INSTALL 20 FEET OF 2 INCH STEEL MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WlXAdditfOtl$ 11age63 of9B
CUSTOMERS BENEFITED
ALL~MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL- MIX
ALL· MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL· MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL- MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
All-MlX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANTIN
LOCATION PURPOSE Of PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISlON SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201"
030 TEXAS DIV!SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INH;GRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTCM INTEGRITY MAY-2016
030 TEX/\$ Dl\llSION SYSTEM ~NTEGRffY MAY-2016
030 TEXl\S DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXl\S DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXl\S DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IITTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TE:XAS DIVISION SYSTEM INTEGRITY MAY"2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER y 2016
030 TEXl\S DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 Tl'XAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXl\S DIVISION SYSTEM INTEGRITY MAY-2016
030 TEX/\$ DIVISION SYSTEM INTEGRITY MAY ~:2.016
030 TEXl\S DIVISION. SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2018
030 TEXl\S DIVISION SYSTEM IMPROVEMENTS MAY-2016 I
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MA.Y-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRffV MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGR:llY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO, PROJECT NUMBER COST(11 COST
2440 030.33466 12 12
2441 030.33492 '2,551 2,551
2442 030.33495 1,096 1,096
2443 030.33502 390 390
2444 030.33503 291 2'11
2445 030.33:510 207 20)'
2446 030.33:512 147 14)'
2447 030.33:513 1,478 1,478
2448 030.33522 2,075 2,075
2449 030.33524 111 111
2450 030.33525 18 18
2451 030.33527 1,368 1,360
2452 030.33531 390 390
2453 030,3353;2 1,565 1,565
2454 030.33533 533 533
2455 030.33544 78 78
2456 030.33546 153 153
2457 030.33554 672 672
2458 030.33562 2,629 2,829
2459 030.33565 168 168
2460 030.33566 24 24
2461 030.33568 1.031 1.031
2462 030.33575 715 715
2463 030.33592 146 146
2464 030.33694 29.990 29,:980
2465 o:m.33600 111 111
2466 030.33601 449 449
2467 030.33602 416 416
2468 030.33606 1,199 1,199
2461) 030.33608 337 337
2470 030.33609 117 117
2471 030.33614 5,512 5,512
2472 030.33623 655 655
247" 030.33626 659 559
2474 030.33629 903 903
2475 030.33630 357 357
2476 030.33633 1,059 1,059
2477 030.33634 198 198
2478 030.33635 1,142 1.142
ATMOS ENERGY CORPORATION, Wf:STTEXAS Ol\/~SIOl'il INTERIM COST RECOVERY AND RATE AOJUS.TMENT REPORT
PROJECT REPORr CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBl.IC USE IN CALENDAR YEAR 2016 (21 BENEFITED
REPIACE 1 SERVICE lN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MlX INSTALL234 FEET OF 4 INCH f'OLY MAIN AND4 SERVICES AND RETIRE 234 FEET OF 3 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.209 ALL-MlX REBUILD METER AND REGULATOR STATION IN ACCORDANCE wm-1 RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 25 FEET OF POLY MAIN ANO RETlRE 25 FEET OF 4 lNCH SlEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MlX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAlLROAD COMMlSSION OF TEXAS RULE 8.209 ALL-MlX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 75FEET OF6 INCH POLY MAIN AND RETlRE 75FEET OF6 INCH STEEL MAIN JN ACCORDANCE WlTH RAlLROAD COMMJSSlON OF TEXAS RULE a.:wo ALL-MIX INST.ALL;BBB FEETOF1.35 INCH POLY MAIN AND RETIRE 888 FEET OF 2 INCH STEEL MAIN AND REPLACE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 1.75 INCfl POLY SERVICE AND RETIRE 11 INCH STEEL SERVICE IN AGCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RLIL~ 8.209 ALL-MlX INSTALLS FEET OF 2 INCH POLY MAIN AND RETIRE 8 FEET CF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 182 FEET OF 2 INCf-1 POLY MAIN AND 2 SERVICE;S AND RETIRE 182 FEET OF 2 INCH STEEL MAIN AND 2 SERVICE IN ACCORDANCE WITfl RAlLROAO COMMISSION OF T!'XAS RULE 8.209 ALL-MIX REPLACE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WlTH RAllROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 137 FEET OF 6 INCH POLY MAIN AND RETIRE 137 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
INSTALL 146FEETOF 4INCHAND14 FEET OF 3 INCH PO\_Y MAIN AND RETlRE 160 FEET OF 3 lNCH STEEL MAIN lN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.200 ALL- MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAlLRDAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPIACE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPIACE 1 SERVICE IN ACCORDANCE WlTH RAlLROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX
DALHART OPERATIONS BLANKET TO COVER REPlACEIRETlRE TASl(S: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGUIATORS AND METER LOOPS IN ACCCORDANCE WITI-1 RAILROAD COMMISSlON OF TEXAS RULE B.209 ALL-MiX REPIACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 8.200 AILL-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COflllMJSSION OF TEXAS RULE B.209 ALL-MIX INSTALL 14 FEETDF6 INCH f'OLYMAINAND RETIRE 14 FEETDFB INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL· MlX INSTALL 301 FEET OF 2 INCH POLY MAIN AND 10 SERVICES AND RETIRE <101 FEET OF 2 INCH STEEL MAIN AND 10 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX INSTALL 1 2 lNCH WELDDVER lN ACCORDANCE WITH RAlLROAD COMMISSlON OF TEXAS RULE 8.209 ALL- MIX INSTALL 6520FEET OF2 INCH POLY MAlNAND RETIRE6520 FEET OF 2 INCH STEEL MAIN AND REPIACE 90 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL·MlX REPIACE 1 SERVICE lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 75 FEET OF 4 INCH POLY MAIN AND 1 SERVICE AND RETIRE 75 FEET OF 3 INCH STEEL MAlN ANO 1 SERVlCE IN ACCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RULE 8.209 ALL-MlX INSTAILL 113 FEET OF 2 INCH POLY MAIN AND3 SERVICES AND RETIRE 113 FEET OF 2 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 AILL-MlX REPLACE 35 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RA!l..ROAD COMMISSION OF TEXAS RULE 8,209 AILL-MIX INSTALL 50 FEETOF2 INCH POLY MAIN AND 1 SERVICE AND RETIRE :50 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE !N ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.209 ALL-MlX REPLACE 5 FEET OF 2 lNCH POLY IN ACCORDANCE WITH RAILROAD CDMMlSSION OF TEXAS RULE 8.209 ALL-MlX INSTALL 1119 FEET OF 21NCH STEEL MAlN AND 32 SERVICES ANO RETIRE 1119 FEET OF 2 INCH STEEL MAIN ANO 32 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL" MIX REBUILD REGUIATOR STAT JON lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 13.2.09 ALL-MIX REBUILD REGUIATOR STATION IN ACCORDANCE WlTH RAlLROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX REBUILD REGULATOR STATION lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REBUILD REGUIATOR STATION IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RULE 8_209 ALL- MIX REBUILD REGUIATOR STATION IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.209 ALL-MIX lNSTALL 5 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 5 FEET OF PLASTIC MAIN AND 1 SERVICE IN ACCORDANCE WlTH RAlLROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REBUll-0 REGUIA TOR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
WTXAddJtJDtl!I: Page 64of98
DA It: !-'LACED IN GAS PLANT IN
l.OCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DlVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRlTY MAY-2016
030 TEXAS DlVtSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION sYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRITY MAY-201B
030 TEXAS DlVISJON SYSTEM INTEGRITY MAY-2015
030 TEXAs DIVISION SYSTEM lNTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM lNTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRllY MAY-2016
030 TEXAS DlVlSIDN SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRllY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRlTY MAY-2016
o:ao TEXAS DIVIS!ON SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM lMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISlON SYSTEM lMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2015
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
LINE ALLOCATE[) NO. PROJECT NUMBER COST(1) COST
2479 030.33639 616 616
2480 030.33841 504 504
2481 030.33843 759 759
2482 030.33645 125 125
2483 oao.aa645 48 4a
2484 030.33647 1,972 1.972
2485 030.336:51 779 779
2466 030.33652 419 419
2487 030.33854 592 592
2488 000.33657 1,313 1.313
2469 030.33658 1.139 1,139
2490 030.33661 357 357
2491 030.33662 4.117 4.117
2492 030.33671 542 542
2493 030.33873 257 257
2494 030.33675 495 495
2495 030.33676 187 167
2496 o:m.33SB7 204 204
2497 030.3368EI 97 97
2498 030.33689 224 224
2499 030.33691 1,863 1.863
2500 030.33892 40 40
2501 030.::13595 118 115
2502 030.33703 549 549
2503 030.33706 100 100
2504 030.33718 394 394
2505 030.33721 309 909
2506 030.33722 176 178
2507 030.33724 144 144
2508 030,33725 230 230
2509 030.33726 166 166
2510 030.33727 37 37
2511 030.33732 306 306
2512 030.33733 429 429
2513 090.33734 160 160
2514 030.33735 207 207
2515 030.33737 6,391 5,391
2516 030.33753 235 235
ATMOS ENERGY CORPORATIOl!f, WtST TliXAs DIVISION INTEFllM COSTRECOVJ:RV AND RAU ADJUSTMENT REPORT
PROJECT REPORT CV W16
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 265 FEET OF 2 INCH POLY MAIN AND 3 SERVICES AND RETIRE 265 FEET OF 2 INCH STEEL MAIN AND 3 SERVlCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 10 FEET OF 2 INCH STEEl AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 lNSTALL 171 FEETOF2 INCH AND52FEETOF 1.:25 INCHPOLY MAIN AND 3 SERVICES AND :RETIRE 220 FEET OF 2 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.209 INSTALL 15 FEET OF21NCH AND 108 FEET OF 1.25 INCH POLY MAIN AND RETIRE 124 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAilROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 21 INCH STEEL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 96 FEET OF 4 JNCH POLY MAIN AND RETIRE 96 FEET OF? INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 149 FEET OF 2 INCH POLY MAIN ANO 4 SERVICES AND RETIRE 149 FEET OF 2 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 50 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 50 FE!OT OF 3 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 68 FEET OF 2 INCH POLY MAIN AND 4 SERVICES AND RETIRE 68 FEET OF 2 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 833FEET OF2 INCH POLY MAIN AND RETIRE833 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 712 FEET OF 2 INCH POLY MAIN AND RETIRE 1813 FEET OF PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 44 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 801 FEET OF 2 INCH AND 50 FEET OF 1.25 INCH POLY MAIN AND RETIRE 051 FEET OF 2 lNCH STEEL MAIN AND REPLACE 22 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSIDN OF TEXAS RULE 8.209 REPLACE 12 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RULE B.209 INSTALL 14 FEET OF 2 INCH POLY MAIN AND 1 SERVICES AND RETIRE 14 FEET OF 2 INCH PLASTIC MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 111 FEET OF 2 INCH STEEL MAlN AND RETIRE 11 O FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TEXAS RULE B.209 REPl.ACE 5 FEET OF 2 !NCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 10 FEETOF2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 10 FEET OF 2 INCH PLASTIC MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPl.ACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL 628 FEET OF 2 INCH POLY MAIN AND 21 SERVICES AND RETIRE 628 FEET OF 2 INCH STEEL MAIN AND 21 SERVICES IN ACCORDA.~CE WITH RMLROAD COMMISS!ON OF TEXAS RULE B.209 INSTALL 8 FEET OF 2 lNCH POLY MAIN AND RETIRE B FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITK RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVlCE IN ACCORDANCE WITH RAILROAD GOMMISSION OF TEXAS RULE B.209 REPLACE RECTIFIER IN ACCORDANCE WITK RAii.ROAD GOMMISSION OF TEXAS RULE 6.209 INSTALL40FEET OFS INCH POLY MAIN AND RETIRE 40FEET OF6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RULE B.209 REPLACE 8 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 11 FEETOF2 INCH POLYMAlNAND RETIRE 11 FEETOF2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TEXAS RULE B.209 lNSTALl9 FEET OF 2 INCH POLY MAIN AND RETIRE 9 FEET OF 2 JNCH STEEL MAIN IN ACCORDANCE WITH RAilROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 10 FEETOF2 INCH POLY MAIN AND RETIRE 10 FEETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLJLE 8.209 INSTALL 61 FEET OF 3 INCH POLY MAIN AND RETIRE 61 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 40 FEET Of STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 64 FEET OF 3 INCH POLY MAIN AND RETIRE 64 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 15 FEET OF 4 INCH POLY MAIN AND RETIRE 15 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL625FEET OF2 !NCH AND 614 FEET OF 4 INCH AND55 FEET OF 2 !NCH POLY MA!N AND RETIRE 1440 FEET OF VARIOUS SIZED STEEL MAIN !N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 8 FEET OF 4 INCH STEEL MAIN AND 1 SERVICE AND RETIRE 8 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLJLE 8.209
WTX Additions Page65 of9.8
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MlX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MlX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX·
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MtX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED"' GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VISION SYSTEM INTOGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM JNTCGRiTV MAY-2016
030 TEXAS DIVISION SVSTtM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS D!V1SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSlEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao T!OXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DMSJON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2.018
030 TEXAS DIVlSION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DiVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1) COST
2517 030.33755 823 623
2518 030.33761 257 257
2519 030_33762 204 204
2520 030.33163 309 309
2521 030.33764 253 253
2522 030.33765 273 273
2523 030.33770 190 190
2524 030.33772 291 291
2525 030.33773 13 13
2526 030.33774 314 314
2527 030.33778 139 139
2.528 030_3'3779 74 74
2529 030.33787 48 48
2530 030.33796 541 541
2531 o:m_a3101 169 169
2532 030.33798 165 165.
2533 030.33799 388 388
2534 030.33801 91 91
2535 030.33802 247 247
25"6 030.33803 133 133
2537 030.33805 130 130
2538 030.33807 1.696 1,896
2539 030.33809 1.516 1,516
2540 030.33810 1,150 1.150
2541 o30.aaa1a 21 21
2542 030.33814 4,834 4,834
2543 030.33819 163 163
2544 030,3:3820 300 a30
2545 030.33822 326 326
2546 030.33828 40,024 40,024
2547 030.33829 42.222 42.222
2548 030.33839 1.924 1.924
2549 030.33841 16 16
2550 030.33842 20 20
2551 030.3'3843 59 59
2552 030.33855 54 54
2553 030.33:858 15,876 15,875
2554 030.33859 282 262
2565 030.33:860 54 64
2556 OJ0.33853 677 677
2557 030.33865 5,643 5,643
ATMOS ENERGY CORPORATION, WESTT~XAS OIV~ION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CV 2016
DESCRlPTtoN OF COMPLETED PROJECTS DEDICATED TO PUBUC USE IN CAUoNOAR YEAR 2016 {2)
REBUILD LARGE VOLUME METER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAO COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET OF 6 INCH STEEL MAIN AND RETIRE 6 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 12 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 12 FEET Of 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCIO WITH RAILROAD COMMISSION Of TEXAS RULE 6.20Q INSTALL 10 FEET OF 2 INCH POLY MAIN AN!l RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 84 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 94 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMJSSION Of TEXAS RULE 8.209 INSTALL 103 FEET OF 2 1NCH POLY MAIN AND 3 SERVICES AND RETIRE 103 FEET OF 2 INCH STEEL MAIN ANO 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 7 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WIT!l RAILROAD COMMISSION OF TEXAS RULE B,209
RETIRE 26400 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 5 FEET OF 4 INCH POLY MAIN AND RETIRE 5 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAU.ROAD COMMISSION OF TEXAS RULE 6,209
INSTALL 8 FEET OF 2 INCH POLY MAIN AND RETtRE 8 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 12 FEET OF 2 INCH POLY MAIN AND RETIRE 212 FEET OF 2 INCH PlASTIC MAIN IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 2207 FEET Of 2 INCH PLASTIC MAIN IN ACCORDANCE WlTH RAl\.ROAD COMMISSION Of TEXAS RULE 8.209 INSTALLS FEET OF 2 INCH POLY AND RETIRE 5 FEET OF 2 INCH PLASTIC IN ACCORDANCE WffH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RET!RE 7 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2.09 REBUILD CPR STATION IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 REBUILD CPR STATION JN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL2750 FEET OF 2 INCH POLY MAIN ANDRETIRE2750 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 12 FEET OF 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 97B FEET OF 2 INCH ANO 20 FEET Of 4 INCH PO!. y MAIN AND RETIRE ao4 FEET OF 2 INCH AND 20 FEET Of 3 INCH STEEL MAIN AND REPLACE 18 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 75 FEET OF 2 INCH POLY MAIN AND RETIRE 75 FEET OF 2 INCH STEEL MA1N IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 9 FEET OF 2 INCH POLY MAIN AND 1 SERVICE RETIRE 9 FEET OF 2 INCH PLASTIC MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 8035 FEETOF2 INCH POLY MAIN AND RETIRE 8718 FEET OF 2 INCH PLASTIC MAIN A~D REPLACE 190 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 8698 FEETOF2 INCHPOLY MAIN AND RETIRE 6789 FEET OF 2 INCH PlASTIC MAIN ANO REPLACE 164 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE REGULATOR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF'TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6_209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REBUILD SETIING IN ACCORDANCIO WITH RAILROAD COMMISSION Of TEXAS RULE 8,209 RETIRE 27 FEET OF 1.25 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISS[ON OF TEXAS RULE B.209 INSTALL 4900FEET Of 6 INCH POLY MAIN AND RETIRE4900 FEET OF 8 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 74 FEET OF 4 INCH POLY MAIN AND RETIRE 7 4 FEET OF 3 INCf-1 STEEL MAIN !N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAil.ROAD COMMISSION Of TEXAS RULE 8.209 REBU!LD LARGE VOLUME METER SETTING IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE a.:me INSTALL852 FEET OF 2 INCH AND382 FEET OF 1.25 INCH POLY MAIN AND RETIRE 1224 FEET OF 2 INCH STEEL MAIN AND REPLACE 10 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX Additions Page 66 cf98
CUSTOMERS BENEFITED
ALL- MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
AL\.-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
All-MIX
ALl.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIK
ALL-MIX
ALL· MIX
ALL-MIX
ALL- MIX
DATO. eLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
000 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2.016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVJSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IITTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGR11Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVJSION SYSTEM INTEGRITY MAY-2010
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016 I
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY~2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IN1EGRITY MAV-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
LINE ALLOCATEO NO. PROJECT NUMBER COST(1) COST
2558 030.33867 223 223
2559 030.33570 358 358
2560 030.33871 184 184
2561 030.33873 2,153 2,153
2562 030.33874 278 278
2563 030.33875 3,118 3,118
256~ 030.33676 163 163
2565 030.33877 206 200
2566 0'30.33878 233 233
2567 030.33879 249 249
2668 030.33880 326 326
2569 030.33861 230 230
2570 030.33882 17,447 17,447
2571 030.33889 221 221
2572 o:m.33891 275 275
2573 030.33892 4,428 4.428
2574 030.33893 288 288
2575 030.33895 1,71.fl 1,716
2576 030.33898 21 21
2577 030.33899 235 235
2578 030.33900 472 472
2579 030,33902 30 30
2580 030.33903 146 146
2581 030.J3914 323 323
2582 030.33916 5,298 5,298
2563 030.33917 230 230
2584 OS0.33920 4B 48
2585 030_33922 386 368
2566 030.33924 7,870 1,a10
2567 030.33926 5,080 5,080
2588 030.33930 662 662
2569 030.33931 211 211
2590 030.33933 00 66
2591 030.33934 57 57
2592 OJ0 ... JJ935 241 241
2593 030.33966 354 354
2594 030.33937 72 72
25"5 030.33936 oO 50
2596 030.:33943 167 167
2597 030.33944 446 446
ATMOS ENERGY CORPORATION, WESTrn<AS DIVISION INTERIM COST RECOVERY AJllD RATE AOJUSTMENt A:fPORT
PROJECT REPORT CV 2Q;l.6
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2015 (2)
INSTALL a FEET OF 2 INCH STEEL MAIN AND RETIRE 8 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMfSSION OF TEXAS RULE 8.209 INSTALL362a FEET OF 2 INCH POLY MAIN AND 15SERVICES AND RETIRE 3626 FEET OF 2 INOli PLASTIC MAIN AND 15 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUlE 8.209 INST ALL 12 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 1147 FEET OF 4 INCH POLY MAIN AND 14 SERVICES AND RETIRE 1147 FEET OF 4 INCH STEEL MAIN AND 14 SERVICES IN ACCORDANCE WITH RAILROAD C:OMMlSSION OF TEXAS RULE 8.209 INSTALL 10 FEET OF 2 INCH STEEL MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCH STEEL MAIN AND RETIRE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 12FEETOF2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 12 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 30 FEET OF 2 INCH POLY MAIN AND RETIRE 30 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 31 FEET OF 2 INCH STEEL MAIN AND RETIRE 31 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 10332FEET OF VARIOUS SIZE STEEL MAIN AND INSTALL 8300 FEET OF 2 INCH POLY MAlN IN ACCORDANCE WITH RAILROAD COMMISmON OF TEXAS RULE B.209 REPLACE 8 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl_E 8.209 REPLACE 8 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1487 FEET OF 2 INCH POLY MAIN AND 15 SERVICES AND RETIRE 1475 FEET OF 2 INCH STEEL MAIN AND 15 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 5.209 REPlACE 1 SERVICE IN ACCORDMJCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 847 FEET OF 2 INCH POLY MAIN AND 13 SERVICES AND RETIRE 674 FEET OF 2 INCH STEEL MAIN AND 13 SERVICES IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 11 INCH STEEL SERVICE IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 13 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 85 FEET OF 2 INCH POLY MAIN AND RETIRE 85 FEET DF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 11 INCH STEE!. SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 :REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.21l9 REPLACE 9 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 795FEET OF2 INCl1 POLY MAIN AND 23 SERVICES AND RETIRE 795 FEET OF 2 INCH STEEL MAIN AND 23 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION DF TEXAS RULE 8.209 INSTALL 17 FEET OF 2 INCH POLY MAIN AND RETIRE 17 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 8 FEET OF 2 INCH POLY MAIN AND RETIRE B FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 111 FEET OF 2 INC!l POLY MAIN AND 3 sERVICEs AND RETIRE 111 FEET OF 2 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLJLE 8;;209 REBUILD 1 SYSTEM REGULATORS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 655 FEET OF 2 INCH POLY MAIN AND 26 SERVICES AND RETIRE 655 FEET OF 2 INCH STEEL MAIN AND 26 SERVICES IN AccoROANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD LARGE VOLUME METER SETTING IN ACCORDANCE wm-1 RAILROAD COMMtSSJON OF TEXAS RULE 8.209 INSTALL WELOOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 RETIRE 5247 FEET OF 2 INCH PLASTIC MAIN IN AcGDRDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 100 FEET OF 2 INCH POLY MAIN AND RETIRE 100 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE B.209 RETIRE 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 45 FEET OF 4 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE B.209 RETIRE 1 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 120 FEET Of 2 INCH POLY MAIN ANO RETIRE 860 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE a.~09 INSTALL 188 FEET OF 2 INCH PDLY MAIN AND 6 SERVICES AND RETIRE 188 FEET OF 2 lNCH STEEL MAIN AND 6 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE :13-209
WTil:Additions Page 67 of98
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
l\Ll-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
UATE PLACEO IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGR!TY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION sYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSIDN SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DllllSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGR!TY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY Ml\Y-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM IJ>ITEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITI' MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2010
0'30 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST~1l COST
2598 030.33946 269 269
2599 o:m.33953 4,224 4,224
2600 03-0.33955 372 372
2801 030.33959 17 17
2602 03-0.33002 8,037 8,037
2603 030.33963 232 232
2504 030.33965 1,980 1,960
2605 030.33967 1.861 1.001
2606 030.33972 2.155 2,155
2607 030.33973 43 43
2608 030.33975 258 258
2609 030.33976 162 162
2610 030.33978 278 278
2611 030.33980 494 494
2612 030.33984 4,108 4,108
2613 0'30,33992 159 159
2614 030.33993 001 861
I
2615 030.33995 431 431
2616 030.33997 262 262
2617 030.34009 334 334
2616 030.34010 156 156
2619 030.34011 288 268
2620 030.34012 771 771
2621 030.34013 71 71
2622 030.34016 276 276
2623 030.34033 418 418
2624 030.34037 191 191
2625 030.34040 605 sos
2626 030.34041 127 127
2627 030.34042 185 185
2628 030.34043 168 168
2629 030.34045 550 550
2630 030.34046 777 717
2631 030.34048 139 139
2632 030.34050 80 80
2633 03-0.34055 4.281 4.281
2634 030.34056 119 119
2635 030.34077 2.613 2.613
2636 030,34078 462 462
2637 030.34080 567 567
2638 030.34082 2,783 2.783
ATMOS ENERGY CORPORATION, WESTl"EXAS DM.SION INTERIM COST R•COVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CY 1016
DESCRIPTION OF COMPLETEll PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL a FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 8 FEET OF 2 INCH PLASTIC MAIN A'lD 1 SERVICE IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL4200 FEET OF 2 INCH POLY MAIN AND RETIRE4200 FEET OF 4 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSIOr.I OF TEXAS RULE 8.209 INSTALL 65 FEET OF 2 INCH POLY MAIN AND RETIRE 65 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITfl RAllROAD COMMISSION OF TEXAS RULE 8.200 RETIRE 4730 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALLBBO FEETOF3 AND s INCH POLY MAIN AND RETIRE 880 FEET OF VARIOUS SIZED STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 9 FEET OF 2 INCH STEEL MAIN AN!l 1 SERVICE AND RETIRE 9 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE Wl1H RAILROAD COMMISSION OF TEXAS RULE a.209 INSTALL 634 FEET OF 4 INCH POLY MAIN AND RETIRE 634 FEET OF 7 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 240 FEET OF 3 INCH POLY MAIN AND RETIRE 240 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE AND LOWER 2 CROSSINGS IN ACCORDANCE WITH RAILROAD COMMISSION OF lEXAS RULE fl.209 S REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETJRE 1 1/4 INCH SERVICE JN ACCORDANCE WITH RAILRO.AD COMMlSSiON OF TEXAS RULE B.209 INSTALL 12 INCH WELOOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 85 FEET OF 2 INCH POLY MAIN ANDRETiRE 85 FEET OF2 INCH sTEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 72 FEET OF 2 INCH POLY MAIN ANDRETlRE 72 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 21 SERVICES AND RETIRE 850 FEE; OF 2 INCH STEEL MAIN AND 21 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.20@ REPLACE 1 SERVICE IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 142 FEET OF 4 INCH POLY MAIN AND RETIRE 142 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 20 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE 5 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 103 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAIUROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 8 FEET OF 2 INCH POL y MAIN AND RETIRE 8 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 42 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 42 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL285 FEET OF 4 INCH POLY MAlN AND RETIRE 284 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE POSITIVE METER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 147 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 147 FEET OF 2 INCH STEEL MAIN AND 2 SEA:VlCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S.200 RETIRE 601 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8-209 INSTAlL207 FEETOF2 INCH POLY MAIN ANO RETIRE 207 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WJTH RAILROAD COMMlSSlON OF TEXAS RULE 8.209 REPLACE 7 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 9 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITM RAILROAD COMMfSSION OF TEXAS RULE B.209 INSTALL 225 FEET OF 2 INCH POLY MAIN AND RETIRE 225 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
RETIRE 30722 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE Wl1}j RAILROAD COMMlsSION OF TEX/IS RULE B.209 INSTALL42 FEET OF 2 INCH POLY MAIN AND RET!RE 42 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WI™ RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 15 FEET OF 3 !NCH STEEL MAIN IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 8 REGULATOR STATIONS IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 40 FEET OF 3 STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 510 FEET OF 2 INCH POLY MAIN AND 7 SERVICES ANO RETIRE 510 FEET OF 3 INCH STEEL MAIN AND 7 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 10 FEET OF 2 INCH POLY MAlN AND RETIRE 10 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1780 FEETOF3 INCHPOLY MAIN AND RETIRE 1780 FEET OF 3 INCH PLASTIC MAlN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 7M ROOTS METER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX Additions Page6Sof98
CUSTOMIORS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All- MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
All-MIX
ALL-MIX
AUL· MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL- MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
All-MIX
All-MIX
All-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DMSION SYSTEM INTEGRl1Y sEPTEMBER-2016
030 TEXAS DIVISION sVSTEM iNTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION PUBUC lMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OMS ION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS OIV!SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION svsn;M INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYsTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SVSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM iNTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRrlY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVtSION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS DIVlSION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DMSION SYSTEM INTEGRl1Y MAV-2016
030 TEXAS DiVl:SION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS Dl\llSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIV!S10N SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
LINE ALLOCATED No. PROJECT NUMBER CDST{1} COST
2639 020,34083 345 345
2640 030.34084 361 361
2641 020.34088 409 409
2642 030.34089 2,4615 2,466
2648 030.34090 95 95
2644 030.34092 162 162
2645 030.34116 186 186
2646 030,34117 238 238
2647 030.34125 224 224
2648 030.34142 370 370
2649 030.34147 39 39
2650 030.34148 1,556 1,555
2651 030.34153 1.980 1,980
2652 030.34158 4,669 4,669
2653 030.34172 352 352
2654 030.34179 4,174 4,174
2655 030.34181 570 570
2656 030.34185 223 223
2657 030.34196 31 31
2656 030.34197 34 34
2659 030.34198 42 42
2660 030.34201 961 961
2661 030.34226 1.224 1,224
2662 030.34227 476 476
2663 030.34228 135 135
2664 030.34231 33 33
2665 030.34235 5,767 5,767
2666 030.34247 12,073 12,073
2667 030,34248 640 64-0
2668 030.34249 292 292
2669 030.34250 0a SB
2670 030.34251 558 558
2671 030.34253 2.418 2,418
2672 030.34254 3,076 3,076
2673 030.34255 303 303
2674 030.34256 403 403
2675 030.34257 651 651
2676 030.34259 219 219
2677 030.34260 31 31
2676 030.34261 941 941
ATMOS t;NfRGY CORPORATION, WEST TEXAS DIVISION INTERIM COST RECOVEl'IY ANO RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2G16 (2}
INSTALL 22G FEET OF 2 INCH POLY MAIN AND 5 SERVICES AND RETIRE 220 FEET OF 2 INCH STEEL MAIN /\ND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 1016 FEET OF 2 INCH POLY MAlN AND RETIRE 101HEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REBUILD LARGE VOLUME METER SETTING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 23 FEET OF 6 INCH AND 9 FEET Of 4 INCH STEEL MAIN AND RETIRE 23 FEET OF 6 JNCH AND 9 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXJ\S RULE8.209 RETIRE 486 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE METER AND REGULJ\TOR !N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 3 INCH WELOOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 27 FEET OF 2 INCH POLY MAIN AND RETIRE 21 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8,209 INSTALL 911 FEET OF 2 INCH POLY MAIN AND RETIRE 2115 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL2930 FEET OF 4 INCH POLY MAIN AND RETIRE 1480 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD CDMMISSlONOFTE:XAS RULE 6.209 INSTALL 1320 FEET OF 4 IMCH POLY MAIN AND 80FEETOF 2 INCH POLY MAIN AND RETIRE 1400 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 6 INCH POLY MAIN AND RETIRIO 20 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209
INSTALL 1083 FEET OF 2 INCH POLY MAIN AND 29 SERVICES AMD RETIRE 1083 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 20 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL22 FEET OF2 INCH POLY MAIN AND RET1RE22 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 346 FEET Of 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 9 FEET OF 4 INCH STEEL MAIN AND RETIRE 9 FEET OF 4 AND 30 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 130 FEET OF 2 INCH POLY MAIN AND 5 SERVICES AND RETIRE 2GO FEET OF 1 INCH STEEL MAIN AND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 2 SERVICES AND RETIRE 570 FEET Of 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RUU: B.209 REPLACE 5 FEETOF2 INCH STEEL MAIN AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL637 FEET OF 4 INCHAND 15 FEET OF 2 INCH POLY MAIN AND RETIRE637 FEET OF 4 INCH AND 15 FEET OF 2 INCH ST!OEL MAIN IN ACCORDANCE WITH RAILROAD COMM!SSION OF TEXAS RULEB.209
INSTALL 4762FEETOF2 INCHPOLYMAIN AND 4762 FEET OF 2 INCH STEEL MAIN AND REPLACE 78 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
RETIRE 25904 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 6699 FEET OF 2 INCH PLASTIC MAlN IN ACCORDANCE; WITH RAILROAD COMMISSION Of TEXAS RULE 8,209 EXTEND VENT PIPE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 S REBUILD REGULATOR STATION IN ACCORDANCE WITH RAILROAD COl'dMISS!ON OF TEXAS RULE 8.209 INSTALL 292 FEET OF 2 INCH POLY MAIN AND 10 SERVICES AND RETIRE 292 FEET OF 2 INCH STEEL MAIN AND 10 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 INST ALL 426 FEET OF 1.25 INCH POLY MAIN AND 3 SERVICES AND RETIRE 426 FEET OF 2 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 5 FEET OF 3 INCH STEEL MAIN /\LONG SOUTHEAST 46TH STREET IN ACCORDANCE WITfl RAILROAD COMMISSION OF IEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 INST ALL 8 FEET OF 4 INCH POLY MAIN AND a FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE !N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 271 FEET OF 2 INCH FOL Y MAIN AND 3 SERVICES AND RETIRE 271 FEET OF 2 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTXAddniOhs :!Jage 69 of98.
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
AL!.-MIX
ALL- MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All- MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL.-MIX
ALL- MIX
ALL- MIX
ALL- MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXJ\S DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRflY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2.016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2G16
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM tNTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
03-0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRflY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAYY201B
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
mm TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
020TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2G16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
LINE NO. PROJECT NUMBER COST(1)
2679 030.34263 570
2680 030.34265 1,133
2681 030.342615 1,109
2682 030.'34267 253
28El'3 OB0,34271 7
2684 030.34272 272
2680 030.34273 3,149
2686 030.34276 60
2687 030.34277 761
2688 030,34279 73
2669 030.34280 4,091
2690 030.34281 17
2691 030.34282 225
2692 030.34293 2.997
2693 030.34286 3,736
2694 030.34287 1,526
2695 030.342:90 716
2696 OJ0.34292 144
2697 030.34296 376
.2698 030.34297 476
2699 OJ0.34299 245
2700 030.34300 5.087
2701 030.34302 250
2702 030.34303 322
2703 030.34304 2.241
2704 030.34305 130
2705 0'30.34306 34
2706 0'30,34307 54
270{ 030.34308 318
270B 030.34311 232
2709 030.34312 380
2710 030,34313 349
2711 030.34314 186
2712 030.34315 80
2713 030.34316 314
2714 030.34319 114
2715 030.34319 25
2716 030.34320 609
2717 030.34323 322
ALLOCATED COST
570
1.133
1,109
253
ATMOS ENERGVCORPORATIOl'I, WEST TEXAS OIVISION INTfRIM COST ROCOVERY AND RATE ADJUSTMENT REPORT
PROJECT REP"O!t.T CY 2016
OESCRIPTION OF COIYJf:ILCTED PROJECTS DEDICATEO TO CUSTOMERS PUBLIC USE IN CALE.NDAR YEAR 2010 [2) BENEFITED
INSTALL 85 FEET OF 4 INCH POLY MAIN AND RETIRE 85 FEET Of 6 INCH STEEL MAIN IN AcCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 192 FEETOF2 INCH POLY MAIN AND RETIRE 192 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 309 FEET OF4 INC!1 POLY MAIN AND RETIRE309 FEET OF 6 INCH STEEt. MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.20:9 ALL-MIX REPLACE 44 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WlTli RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
7 COMMISSION OF TEXAS RULE 6.209 ALL-MIX
272
3,149
60
761
73
4,091
17
225
2,897
3,736
1,528
716
144
378
476
246
0.001
250
322
2.241
130
34
54
316
232
380
349
186
80
314
114
25
609
322
REBUILD REGULATOR IN ACCORDANCE wrrn RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 328 FEET OF 1.25 INCH POLY MAIN AND 5 SERVICES AND RETIRE 328 FEET OF 2 INCH STEEL MAlN ANO 5 SERVICES IN ACCORDANCE WIT'1 RAILROAD COMMISSION OF TEXAS RULE a.209 REBUILD CPR STATION IN ACCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RULE 8.:209 INSTALL 5 FEET OF 2 INCH POLY MAii<! iN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 998 FEET OF 2 INCH POLY MAIN AND 11 SERVICES AND RETIRE 1307 FEET OF 2 INCH STEEL MAIN AND 11 SERVICES IN ACCORDANCE WITH RAILROAD COMMISStON OF TEXAS RULE 8,209 RETIRE SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 299 FEET OF 2 INCH POLY MAIN 1 SERVICE AND RETIRE 288 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL421 FEET OF 2 INCH POLY MAIN AND RETIRE 421 FEET OF 2 INCH STEEL MAIN AND REPLACE 12 SERVICES IN ACCORDANCE WffH RAILROAD CDMMISSlON OF TEXAS RULE 8.209 INSTALL975 FEET OF 2 INCH POLY MAIN AND 15 SERVICES AND RETIRE 975 FEET OF 2 INCH STEEL MAIN AND 15 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 94 FEET OF 4 INCH POLY MAIN AND 1 SERVICE AND RETIRE 94 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 124 FEET OF 4 INCH POLY MAIN ANO RETIRE 124 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 9,209 INSTALL 1 3 JNCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 125 FEET OF 4 INCH POLY MAIN AND RETIRE 125 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE wrrn RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 276 FEET OF 2 INCH POLY MAIN AND RETIRE 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR ST/\TION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1171 FEET OF 2 INCH POLY MAIN AND RETIRE 1171 FEET OF 2 INCH STEEL MAIN AND REP!ACE 34 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RE!!UllO MASTER METER SETTING DUE TO IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 IN ACCORDANCE WITH RA;LROAD COMMISSION OF TEXAS RULE 8,209 REBUILD METER SETT~NG IN ACCORDANCE WITH RAilROAD COMM!SSION OF TEXAS .RULE 8.209 INSTALL 274 FEET OF 2 INCH POLY MAIN AND RETIRE 274 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 45 FEET OF 2 INCH PO!. Y MAIN AND RETIRE 40 FEET OF 2 INCH sn;EL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 1 WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 2 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE STEEL RISER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL B FEET OF 4 INCH STEEL MAIN AND RETIRE 8 FEET OF 4 INCH STEEL MAIN IN AcCOR!JANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 78 FEET OF 2 INCH POLY MAIN AND RETIRE 6B FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
INSTALL 14 FEET OF 2 INCH POLY MAIN AND RETIRE 14 FEET OF 2 INCH PLASTIC MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 213 FEET OF 4 INCH POLY MAIN AND RETIRE213FE;ET OF 3 INCH STEEL MAIN IN ACCORDANCE WITK RAILROAD COMMISStON OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 42 FEET OF 2 INCH POLY MAIN AND RETIRE 42 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 20 FEETOF2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RUlE B,209 RETIRE 1 SERVICE IN ACCORDANCE wmi RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 165 FEET OF 2 INCH POLY MAIN AND RETIRE 185 FEET OF 2 INCH SToEL MAIN AND REPLACE 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL226 FEET OF 2 INCH POLY MAIN AND RETIRE 226 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WIT!l RAILROAD COMMISSION OF TEXAS RULE 8.209
WT)( Additions Pa:g:e 70 of93
All-MIX
ALL-MIX
ALL-MJX
ALL-MJX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL.MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PlACEO IN GAS PLANT IN
LOCATION PURPOSE Of PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRJTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY~2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SY8TEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY I MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSl'~M INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MA.Y-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-201fl
000 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAV-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRiTY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030.TEXAS DIV!SlON SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2015
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
LINE Al-LOCATED NO. PROJECT NUMBER COST{1} COST
2718 030,34329 205 205
2719 030.34343 717 717
2720 o:ao.343116 "" 86
2721 030.34353 388 388
2722 030,34354 290 290
2723 030.34356 57 57
2724 000.34357 709 709
2725 000.34358 48 48
272'; 030.34362 55 55
2727 030.34363 235 235
2729 030.34364 550 550
2729 030.34387 2,285 2,285
2730 030.34369 636 636
2731 030.34•71 400 400
2732 030.34376 1,035 1,035
2733 030.34377 17 17
2734 03-0.34379 37 37
2735 030.34361 909 909
2736 030.34383 305 305
2737 030.34365 28 28
27•• 030.34388 92 92
2739 Oo0.34389 356 356
2740 030.34404 4,577 4,577
2741 030.34405 330 330
2742 030.34400 296 296
2743 030,34407 316 316
2744 030.34410 437 437
2745 030.34417 255 255
2746 030.34424 14 14
2747 030.34430 220 220
2748 030.34433 92 92
2749 000.34434 559 559
2750 030.34436 423 423
2751 030.34438 34 34
2752 030.34439 59 59
2753 030.34443 527 527
2754 030.34447 126 126
2755 030.34448 47 47
2756 030.34449 56 56
2757 0'30.34452 281 281
2758 030.34453 2,940 2,940
ATMOS E"NER.GV COR:PORJ\TEON, WEST TEXAS OIVlSION iNH;FtlM CO.ST RECOVERY A.ND RATE AD..lUSTMENT REPORT
PROJECT REPORTCV2016
DESCRIPTION OF COMPLETED PROJECTS DEOiCATJ:D TO PUBLIC USE IN CALENDAR VEAR 2016 [2)
REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 14 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 12 FEET OF 2 INCH POLY MAIN AND RETIRE 12 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 14 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200 RETIRE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMJSSION OF TEXAS RULE 8.209
INSTALL 12 FEET OF 4 INCH STEEL MAIN AND RETIRE 5 FEET OF 3 INCH AND 7 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE Will-I RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE IN ACCORDANCE WITK RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 10 FEET OF 2 INCH STEEL MAIN ANO RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 12 FEET OF 3 INCH STEEL MAIN AND RETIRE 12 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl_E 8,209 INSTALL 4520FEET OF2 INCH POLY MAIN AND RETRJE 4520 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 259 FEET OF 2 INCH AND62FEET OF 1.25 INCHPOLY MAIN AND RETIRE 321 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 60 FEET OF 4 INCH STEEL MAIN AND RETIRE80FEETOF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INST ALL 450 FEET OF 2 INCH POLY MAIN AND 2 SoRVICES AND RETIRE 450 FEET OF 4 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8,209 RETIRE 4 FEET OF INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 20 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE LARGE VOLUME METER SETTING DUE TO SYSTEM INEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXJ\S RULE 8,209 lNST ALL 22 FEET OF 2 INCH OF POLY MAIN AND RETIRE 22 FEET OF 3 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 303 fEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 44 FEET OF 2 INCH STEEL MAIN ANO RETIRE 44 FEET OF 2 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 1134 FEET OF 2 INCH POLY MAIN AND 1134 FEET OF 4 INCH STEEL MAIN AND REPLACE 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 12 FEETOF2 INCH POLY MAIN AND RETIRE 12FEETOF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF T!'XAS RULE S.200 lNSTAll 1 WELDOVE:R IN ACCORDANCE WITH RAILROAD COMMISSJON OF TEXAS RULE 8.209 INST ALL 155 FEET OF 2 INCH POLY MAIN ANO RETIRE 155 FEET OF 2 INCH STEEL MAIN AND REPLACE 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RULE 8.209 REPLACE 14 FEET OF 4 INC!1 STEEL MAIN IN ACCORDANCE WITH RMlROAD COMMtSSJON OF TEXAS RULE 8,209 INSTALL 128 FEET OF 2 INCH POLY MAIN AND RETIRE 128 FEET OF 3 INCH S1EEL MAIN IN ACCORDANCt: WITH RAILROAD COMMISSION OF TEXAS RlJLE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLJLE 8.~9 RETIRE OBOOLElE METERS IN ACCORDANCE WITH RMLROAD COMMISSION OF TEXAS RULE 8.209 RETIRE REGULATOR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLJLE 8.~9 INSTALL 1 0.75 INCH POLYSERVICEJ\ND RETIRE 11 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLJLE 8.209 INSTALL 22 FEET OF 2 INCH POLY MAIN ANO RETIRE 22 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RLJLE8.209 RETIRE METER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 8 FEET OF 2 INCH STEEL MAlN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF T!OXAS RULE 9.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE LARGE VOLUME METER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE METER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTAL!. 84 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 64 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 434 FEET OF4 INC!1 POLY MAIN AND RETIRE434 FEET OF 3 ~NCH STEEL MAIN AND REPLACE 7 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX Additions P.jljge:71of98
CUSTOMERS BENCFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL- MIX
ALL~MIX
ALL-MIX
All-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL- MIX
ALL-MIX
AL!.-MIX
DATE PLACED IN GASPLANTlN
LOCATION PURPOSE OF PROJECT SERVICE
000 TEXAS DIV1SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS D!VJSION SYSTEM INTEGRITY MAY-~16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030-TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNlEGR!lY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
o:m TEXAS DIVIStON SYSTEM INTEGRITY MAY-2010
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-~16
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISlON SVSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OMS ION BYSTEM IMPROVEMENTS OCTOBER -2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS DiVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao Tl=XAS DIVISION SYSTEM IMPROVEMENTS OCTOBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST ft) COST
2759 030.34454 1,736 1,738
2760 030.34455 4,394 4,394
2761 030.34456 212 212
2762 030.34457 163 163
2763 030.34459 120 120
2764 030.34468 59 59
2765 030.34470 515 515
2766 030.34473 316 31B
2767 030,34474 95 95
2768 03-0.34480 390 390
2769 030.34484 766 766
2770 030.34486 209 209
2771 030.34489 956 956
2772 030.34496 246 246
2773 030.34500 336 336
2774 030.34502 249 249
2775 030.34505 485 465
2776 030.34511 203 203
2777 030.34512 1,016 1,016
2778 030.64519 298 296
2779 030.34521 81 81
2760 030,34022 15 15
2781 030.34523 1,513 1,513
2762 030.34524 34 34
2783 030.34528 571 571
2.784 030.34533 243 243
2765 030.34536 4,032 4,032
2766 030.34541 228 228
2787 030.34543 525 525
2788 03-0.34670 285 285
2789 03-0.34573 1,975 1,975
2790 03-0.34563 547 547
2791 030.34589 211 211
2792 030,34590 196 198
2793 030.34:591 240 240
2794 030,34592 332 332
2795 030.34593 365 385
2796 030.34594 541 541
2797 030,34599 258 256
2796 030.34600 337 337
2799 030.34001 8,025 8.626
ATMOS ErJERGVCORPORATION, WEST TEXAS DIVISION lNTfRIM COST RECOVERY ANO RATE ADJOSlMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 [2}
INSTALL44 FEET OF 3 INCH POLY MAIN AND RETIRE 44 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 795 FEET Of 2 INCH POLY MAIN AND RETIRE704 FEE"T Of 2 INCH STEEL MAIN AND REPLACE 15SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INST ALL 19 FEET OF 2 INCH POLY MAIN AND RETIRE 19 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8_209 INSTALL 11 FEET OF 2 INCH STEEL MAIN ANO RETIRE 11 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALl 2 INCH WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 154 FEET OF 4 INCH POLY MAIN AND RETIRE 154 FEET OF 3 INCH STEEL MAIN AND REPl-ACE 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
INSTALL 74 FEETOF2 INCH POLY MAIN /\ND RETIRE 74 FEET OF 2 INCH STEEL MAIN AND REPLACE 2 SERVICES IN ACCORDA~CE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
INSTALL 56 FEET OF 2 INCH PDL Y MAIN AND RETIRE 56 FEll OF 2 INCH STEH MAIN AND RIOPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REBUILD 17 METER SETTINGS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 16 FEET OF 6 INCi-i POLY MAIN AND RETIRE 16 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 10 FEET OF 2 INCH STEEL MAIN AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 114 FEET Of 3 INCH POLY MAIN AND RETIRE 114 FEET OF 3 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION IN ACCORDAMCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGUl-ATDR STATION DUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 23 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL400FEET OF2 INCHPOLY MAIN AND RETIRE 400 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RllLE 8,209 REPLACI:: 1 ao FEET OF 6 ~NCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 7 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 90 FEET OF 2 INCH STEEL MAiN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
INSTALL 51 FEET OF 4 INCH AND 271 FEET OF 2 INCH PO\. Y MAIN AND RETIRE 51 FEET Of 4 INCH AND 271 FEET Of 2 INCH STEEL MAIN AND REPLACE 7 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8-209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 66 FEE"TOF 2 INCH POt.Y MAIN AND RETIRE 66 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 5280 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 1050FEET OF2 INCflPOLY MAIN AND RETIRE 1050 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_208 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 INSTALL 323 FEET OF 2 INCH POLY MAIN AND RETIRE 323 FEET OF 2 INCH STEEL MA~N AND REPLACE 5 SERVICES IN ACCORDANCE WlTH RAILROAD COMMISmDN OF TEXAS RULE 6.209 INSTALL 46 FEETDF2 INCH POLY MAIN ANO RETIRE 46 FEE"TOF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2883 FEET Of 2 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXJ\S RULE 8.209 REPLACE 5 FEET OF 2 INCH STEIOL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RU.E 8.209 REPLACE 5 FEET OF 2. INCH STEEL MAIN lN ACCORDANCE WlTH RAILROAD CDMMISS!ON OF TEXAS RULE 8.209 REPLACE 22 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 13 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 5 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 6 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROJ\D COMMISSION OF TEXAS RULE 6.209 INST All 60 FEET OF 4 INCH POLY MAIN AND RETIRE 60 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 7 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 24 FEll OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RA1LROAD COMMISSION OF TEXAS RULE B.209 INSTALL 1751 FEET OF 6 INCH POLY MAIN AND RETIRE 1751 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAs RULE 8.209
WEXAdditions Page 72 of98
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL· MIX
ALL-MIX
All-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL~MiX
ALL-MIX
ALL·MlX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
Ail-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
All-MIX
ALL-MIX
DATE Pl-ACED IN GAS Pl-ANTIN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY~2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-20116
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY·2016
030 TEXAS D!VISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2.016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
03-0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY S~PTEMBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 'l'~:S OMSJON SYSTEM INTEGRITY MAY-'201e
0'30 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1) COST
2800 030.34604 265 265
2ao1 030.34609 629 629
2802 030,34613 464 464
2003 030.:a4C.14 530 530
2604 030.34625 """ 886
;2805 030.34639 415 415
2606 030.34643 117 117
2807 030.34645 82 82
2808 000.34650 9,859 9,859
2809 030.34672 349 349
2810 030.34673 238 238
2811 030.34674 309 309
2812 030.34675 211 211
2813 030.34676 249 249
2814 O:l0.34677 173 173
2815 030.34683 216 216
2816 030.34684 755 755
2817 030.34690 209 239
2818 030.34691 158 108
2819 0JO.:a4695 256 256
2820 030.34700 4.714 4.714
2821 030.34704 63 63
2822 030.34705 311 311
2823 030.34706 722 722
2824 030.34709 335 335
2825 030.34712 73 73
2826 030.34713 545 545
2827 030.34714 986 986
2828 030.34717 269 269
2829 030.34718 651 551
2830 030.34719 34 34
2831 030.34720 527 027
2832 030.34721 424 424
2833 030.34731 2"6 236
2834 030.347a2 259 259
2835 030.34734 062 562
2836 030.34735 122 122
2837 030.34737 10,265 10,265
ATMOS ENERGVCORl'OllATION, WESTTEXAS DIVISION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBUC USE IN CALENDAR YEAR 2016 (2)
INSTALL 5 INCH ENCIRCLEMENT IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE B.209
IMSTALL 10 FEET OF 4 INCH Pol. Y MAIN AND RETIRE 10 FEET OF 3 INCH STEEL MAIN AND REPLACE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
lNST All 32 FEET OF 4 INCH POLY MAIN AND RETlRE 32 FEET OF 3.5 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.20:9 RETIRE 548 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL BO FEET OF 4 INCH AND 380 FEET OF 1.25 INCH POLY MAIN AND 2 SERVICES AND RETIRE ao FEET OF 4 INCH STEEL AND 3BO FEET OF 2 INCH PLASTIC MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 INSTAll 65 FEET OF 4 INCH POLY MAIN AND RETIRE 65 FEET OF 3 INCH ST<;EI. MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INST All 10 FEET OF 2 INCH POLY MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 2000 FEET OF 4 INCH POLY MAIN AND RETIRE 2000 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 8FEET OF 4 INCli POLY MAll>IAND RETIRES FEET OF 3 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 21 FEET OF 2 INCH STEEL MAlN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 28 FEET OF 2 INCH POLY MAIN AND RETIRE 28 FEET OF 2 INCH STEEi. MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 13 FEET OF 2 INOH STEEL MAIN IN ACCORDANCE WITli RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 15 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST Al.L 64 FEET OF 4 INCH STEEL MAIN AND RETIRE 62 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E B.209 REPLACE 42 FEET OF 2 INCi-i STEEL MAIN AND 1 SERVICES IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 148 FEET OF 2 INCH POLY MAIN AND RETIRE 148 FEET OF 2 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 20 FEET OF 2 INCH POLY MAIN AND RETIRE 23 FEET OF 2 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMJSSION OF TEXAS RULE 8.209 INSTALL5 FEET OF 2 INCH POLY MAIN AND RETIRE 5 FEET OF 2 lNCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.21l9 INST ALL 700 FEET OF 6 INCH STEEL MAIN AND RETIRE 690 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 7 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 32 FEET OF 2 INCH POLY MAIN AND RETIRE 32 FEET OF 2 INCH STEEi. MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST All 10 FEET OF 2 INCH POLY MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 42 FEET OF 2 INCH POLY MAIN ANDRETIRE42 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 288 FEET OF 2 INCH PoLY MAIN AND RETIRE 288 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMlSSlDN OF TEXAS RULE B.::me INSTALL 8 INCH WELOOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXl\S RULE B.209 INSTALL 210 FEET OF 1.25 INCH POLY MAIN AND RETIRE 210 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 2 INCH ENCIRCLEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL SFEET OF2 INCH POLY MAIN AND RETIRES FEET OF 2 INCfi STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 12 FEET OF 2 INCH POLY MAIN ANO RETIRE 12 FEET OF 2 ~NCH STEEL MAIN IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 106 FEET OF 2 INCH POLY MAIN AND RETIRE 106 FEET OF 2 INCH STEl'L MAIN AND REPLACE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL34 FEET OF 4 INCH POLY MAIN AND RETIRE 34 FEETOF3 INCH STEEL MAIN IN ACCORDANCE WITH RAl!.ROAD COMMISSION Of TEXAS RULE 8.209 INSTALl.100 FEETOF2 INCH POLY MAIN AND RETIRE 100 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL2S07 FEET OF 21NCH POLY MAIN ANDRETIRE29B4 FEET OF 3 INCH STEEL MAIN AND REPLACE 36 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSJON OF TEXAS RULE a.200
WTXAddUion.s Page 73 of-98
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
Al.l-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALl.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
All-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
Al.L-MIX
ALL-MIX
ALL- MIX
ALL- MIX
ALL-MIX
All-MIX
.., ..... ,""1='1..ACE01N GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISI0!-1 SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
O:lO TEXAS DIVISION SYSTEM INTEGRITY MAY~2016
o:.io Tl'XAs DIVISION SYSTEM INTEGRITY MAY-201B
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYST<;M INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
00-0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
O:lO TEXAS OIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
OBO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAY ·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY.2.016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201"
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATE:O NO. PROJECT NUMaER COST[1) COST
2838 030.34738 224 224
2839 030.34739 303 333
2840 030.34740 66 66
2841 030_34742 116 116
2842 030.34744 7"6 736
2843 030.34746 2.091 2,091
2844 030.34747 751 751
2845 030.34746 194 194
2846 030.34761 552 552
2847 030.34752 6,122 6,122
2848 030.34754 S,899 6,899
2849 030.34761 915 915
2850 030.34764 286 286
2851 030.34769 :366 366
2852 030,34770 169 169
2853 030.34772 460 460
2854 030.34773 2,975 2,975
2855 030.34774 145 145
2856 030,34775 3,135 3,135
2857 030.34700 454 454
2656 030.34781 1,022 1.022
2859 030.347:B3 231 231
2860 030.34764 17 17
2861 030.34766 562 582
2062 030.34790 229 229
2663 030.34791 2,226 2.228
21164 030.34793 104 104
2005 030.34794 246 246
21166 030.347-96 785 785
21167 030.34798 181 181
2866 030.04802 18,403 18,403
2869 030.34803 719 719
2870 030.34804 2,352 2,352
2871 030.34605 97 97
2H72 030.34806 1,513 1,513
2873 o30.a4a21 136 1"6
2874 030.34822 364 364
ATMOS E"NERGY CORPORATION, WESTTEXAS DIVISION INTERIM COST RECOVERY ANO RATE ADJUSTMENT REl'ORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS OEOICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 79 FEET OF 2 INCH POLY MAIN AND RETIRE 79 FEET OF 2 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 214 FEET Of 2 INCH POLY MAIN ANO 1 SERVICE AND RETIRE 214 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 74 FEET OF 4 INCH POLY MAIN AND RETIRE74 FEET OF 3 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL97FEET OF 4 INCH POLY MAIN AND RETIRE 97 FEET OF 3 INCH STEEL AND REPLACE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTAL!.383 FEET OF 2 INCH POLY MAIN AND RETIRE 363 FEET OF2 INCH STEEi- MAIN ANO REPLACE 11 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPl-ACE 134 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 21 FEET OF 2 INCH POLY MAIN AND RETIRE 23 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 89 FEET OF 2 INCH POLY MAIN AND RETIRE M FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8_209 INSTALL 1515 FEET OF 2 INCH POLY MAIN AND RETIRE 1515 FEET OF 2 AND 3 INCH STEEL MAIN AND REPLACE 40 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 7984 FEET OF 2 INCH POLY MAIN AND 7 SERVICES AND RETIRE 7900 FEET OF 2 INCfl PLASTIC MAIN IN ACCORDANCE wm-1 RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE LARGE VOLUME METER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE as FEET OF 2 INCH STEEL MA!N AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALi- 94 FEET OF 2 INCH POLY MAIN AND RETIRE 94 FEET OF 3 INCH STEEi- MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPl-ACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209
INSTAU. 3B FEET OF 2 INCH POLY MAIN AND RETIRE 38 FEET OF 3 INCH STEEL MAIN AND REPLACE 1 SERViCE IN ACCORDANCE WITH RAILROAD COMMISSION Pf TEXAS RULE 8.209 INSTALL 719 FEET OF 2 INCH POLY MAIN AND RETIRE 719 FEET OF 2 INCH STEEL MAIN AND REPLACE 22 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 7 FEET OF2 INCH POl-Y MAIN AND RETIRE 7 FEE.T Of 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 425 FEET OF 4 INCH AND 101 FEET Of 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 425 FEET OF 4 INCH AND 101 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAllROAO COMMISSION OF TEXAS RULE 8,209 REPLACE 16 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 6 FEET OF 4 INCH POLY MAIN AND RETIRE 6 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAO COMMISSION OF TEXAS RULE 8.209 INSTALL 14 FEET OF 3 INCH POLY MAIN AND RETIRE 14 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B,209
RETIRE 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WffH RAILROAD COMMISSION DF TEXAS RULE 6.209 REPLACE BREACH IN ACCORDANCE WITl-I RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 3 INCH DRESSER COUPLING IN ACCORDANCE WITH RAlLROAD COMMISSION DF TEXAS RULE 8.209 REPLACE 3 INCH DRESSER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 REPLACE ao FEET OF 6 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 REPLACE 20 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE CP SECTIONS IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 46 FEET OF 2 INCH ANO 31 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAO COMMISSION OF TEXAS RUl-E 8.209 INSTALL 552 FEET OF2 INCH POLY MAIN AND RETIRE543 FEET OF 2 INCH STEEL MAIN AND REPLACE 9 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF2 INCH POLY MAIN AND RETIRES FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAii-ROAD COMMISSION OF TEXAS RULE B,209 INSTALL 277 FEET OF 4 INCH POLY MAIN AND 5 SERVJCES AND RETIRE 277 FEET OF 4 INCH STEEi- MAIN AND 6 SERVICES IN ACCORDANCE Will-! RAllROAO COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPl-ACE 10 FEET OF 4 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209
WOCA.ddmo.ns Paee74Qf98
CUSTOMERS BENEFITED
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
Al-L-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
Al-L-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
All-MIX
All-MIX
ALL-MIX
All-MIX
ALl-MlX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVJSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVJSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITI' MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY JUNE-2016
0'30 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
o:m TEXAS DIVISION SYSTEM iNTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVJS~ON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION svsn;M INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVJSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVIStON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVIS!ON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER C0ST(1} COST
2875 030.3462'1 1,538 1,538
2876 O'l0.34826 446 446
2877 030.34628 351 351
2878 030.34832 317 317
2879 030.34834 656 656
2880 030.34835 3,672 3,672
2881 030.34838 1,414 1,414
2862 030.3~839 285 285
2.883 030.34840 356 356
2884 030.34:1342 27 27
2885 030.34843 72 72
2686 O'l0.34846 6,403 6,403
2667 030.34847 95 95
2888 030.34849 28,011 28,011
2689 030.34650 107 107
2690 030.34651 177 177
2891 030.34Bfi2 256 258
2892 030.J4927 1,342 1,342
2893 030.:a4928 232 232
2894 030.34929 551 551
2895 030.34931 42 42
2896 030.34935 1,101 1,101
2597 030.'34936 410 410
2698 030.34990 516 516
2899 030.35013 19,476 19,476
2900 030.35014 120 12Q
2901 030.35015 144 144
2902 030.35016 818 818
2003 030.30027 56,493 56,493
2904 030.35046 1S6 166
"905 030.35047 507 507
"906 030.35048 2,400 2.400
2907 030.35050 2,:624 2,824
2908 030.35082 611 611
2909 030.35086 158 158
2910 030.35-091 169 169
2911 030.36116 3"'3 336
2912 030.35120 419 419
2913 030.35124 304 304
2914 030.35130 403 403
ATMOS ENERGY CORPORAnDNt WEST TEXAS OMSION
INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT PROJECT REPORT CV 2016
DESCREPTION OF COMPLETED PROJECTS DEDICATED TO PUBUC USE IN CALENDAR YEAR 2016 (2}
INSTALL 300 FEET OF 4 INCfl POLY MAIN AND REPLACE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 9 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 47 FEET OF 4 INCH POLY MAIN AND RETIRE 47 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALi- 723 FEET Of 2 INCH POLY MAIN ANO RETIRE 941 FEET OF 3 INCH AND 144 FEET OF 4 INCH STEEL MAIN AND REPLACE 11 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6,209 REPLACE AND RELOCATE FACILmES: INST ALL 208 FEET OF 2 INCH POLY MAIN AND RETIRE 206 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE REGULATOR VALVE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL2695 FEET OF2 lNCH POLY MAIN AND RETIRE2755 FEET OF 2 INCH POLY AND 3 INCH STEEL MAIN AND REPLACE 26 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6996 FEET OF 2 INCH POLY MAIN AND 42 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 REPLACE 6 FEET OF 3 JNCH STEEL MA~N AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S.209 REPLACIO 40 FEET OF 3 INCH STEEL MAIN AND 1 SERVlCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL WELDOVER IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.209 REPLACE METER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMM~SSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IM ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 57 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 203FEET DF2 lNCH POLY MAIN AND RETIRE 1096 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH .RAILROAD COMMISSION OF TEXAS RULE e.209 INSTALL 165 FEET OF 2 INCH POLY MAJN AND 3 SERVICES AND RETIRE 165 FEET OF 3 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2300 FEET OF 4 INCH POLY MAIN AND RETIRE 2300FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RULE 8,209 RETIRE 1 SERVICE IN ACCORDA.'lCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 3 STEEL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 37 FEET OF 4 INCH POLY MAIN AND RETIRE 37 FEET OF 3 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 10 FEET Of2 INCH POL V MAIN AND RETIRE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMlSSfON OF TEXAS RULE B.209 INSTALL 123 FEET OF 2 INCH POLY MAIN AND RETIRE 123 FEET OF 2 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1192 FEET DF2 INCH POLY MAIN AND RETIRE 1190 FEET OF 2 INCH STEEL MAIN AND REPLACE 14 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209
INSTALL 370 FEET OF 2 INCH POLY MAIN AND RETIRE 63 FEET OF 3 INCH AND 370 FEET OF 2 INCH STEEL MAIN AND REPLACE 9 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEX/IS RULE 8.209 REPLACE 7 FEET OF 3 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVJCE IN ACCORDANCE W!TH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 12 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 6 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WIX Additions Page '15 of:98
CUSTOMERS BENEFITED
ALL-MIX
ALL· MIX
ALL-MIX
ALL· MIX
ALL-MIX
A\.\.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL- MIX
ALL-MIX
Al.L- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MfX
ALL- MIX
Otl1E.PL.ACED IN GAS PLANTIN
LOCATION PURPOSE OF PROJECT S!':RVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
O'lO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
O'lO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
O'lO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 n;XAS OIVlslON SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY,2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OMSlON GROWTH OCTOBER· 2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRrTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lr-ITEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201£
LINE NO. PROJECT NUMBER COST(11
2915 030.35140 533
2916 030.35141 596
2917 030.35150 900
2918 030.35256 33,520
2919 030.35257 721.546
2920 030.35258 23,828
2921 030.35260 51.056
2922 030.35261 202.76J
2923 030.35262 12.361
2924 060.35263 273,005
2925 030.352B4 22,9016
2926 030.35265 1,258,132
2927 030.35200 103,18'1
2926 030.35267 791
2929 030.35266 m
2930 030.35269 215,5B9
2931 030.35270 1.040
2932 030.35272 0
2933 030.35273 508
29J4 030.35274 98.o39
2935 030.35275 46.BM
ALLOCATED COST
533
598
900
33.520
721,546
23,828
51,056
202,763
12,361
273,665
22,906
1,258,132
103,184
791
ATMOS ENERGY CORPORATION. W£SI TEXAS DMStON INTER!M COST RfOOVERY ANO .AATE ADJUSTMENT REPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 (2) BENEFITED
INST ALL 75 FEET OF 2 INCH POLY MAIN ANO RETIRE 75 FEET OF 2 INCH STEEL Ml\IN IN ACCORDANCEWl1H RAii.ROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 25 FEET OF 6 INCH STEEL WITH STEEL AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 6.209 AU.·MIX INST ALL 90 FEET OF 4 INCH POLY MAIN AND REITER 90 FEET OF 90 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH Rl\ILROAD COMMISSION OF TEXAS RULS 6.209 AU.-MIX INSTALL 5007 FEST OF 21NCH POLY MAIN AND RETIRE8990 FEET OF VARIOUS SIZES OF POLY AND STEEL MAIN AND REPLACS 721 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TSXAS RULS 8.209 ALL· MIX
LUBBOCK OPERATIONS BLANKET TO CDVffi RSPLACEJ!lSTIRE TASKS: SERVICE LINES, PIPE 5 FeET TO 99 FeET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH Rl\ILROAO COMMISSION OF Tl=XAS RULE 6.209 ALL-MIX
LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS. REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.2.09 ALL-MIX
LUBBOCK OPERATIONS BLANKET TO COVER RSPLACEIRETIRE TASKS: SERVICE LINES, PIPE5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCS WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 ALL- MIX
LITTLEFIELD OPERATIONS BLANKET TO COVER REPLACBRSTIRE TASKS: SERVICE LINES, PIPE 5 FSET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, :REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSJON OF TEXAS RULE 8.209 ALL- MIX
LITTLEFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERV~CE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TSXAS RULE 8.209 ALL-MIX
PLAINVIEW OPERATIONS BLANKET TO COVER REPLACEJ!lETIRE TASKS: SERVICE LlNES, Pl PE 5 FEET TO 99 FEET OFLESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AN:D METER LOOPS IN ACCCOROANCE WITH RAILROAD COMMISSION DF TEXAS RULE 8.209 ALL- MIX
PLAINVIEW OPERATIONS Bl~~KETTO COVER REP'LACEJRETlRE TASKS: SERVICE LINSS, PIPE 5 FEET TO 99 FEET OF Less THAN B INCH DIAMETER. ANODES, METSRS. REGULATORS AND METffi LOOPS IN ACCCO.RDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 All-MIX
AMARILLO OPERATtONS BLAl\IKET TO COVER REPLACE/RETIRE TASKS: SERVlCE LINES, PIPE 5 FEET TO 99 FEET OF LESS TrlAN B INCH DIAMETER, ANODES, METERS, REGUtATORS AND METER LOOPS IN ACCCOROANCE WITH RAILROAD COMMlSSION OF TEXAS RlJLE a.209 ALL-MIX
AMARILLO OPERATIONS BLANKET TO COVER REPLACBRETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99FEETOFl.ESS1HAN B INCH DIAMETER. ANODES. METERS, REGULATORS AND METSR LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX
AMARILLO OPERATIONS BLANKET TO COVER REPLACBRETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES. METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAO COMMISSION OF TEXAS RULE 8.209 ALL-MIX
AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TAsKS: SERVICE LINES. PIPE 5 FEET TO !l9 FEET OF LESS THAN 8 INCH DIAMETER. ANODES. METSRS, REGULATORS AND METER LOOPS IN ACCCOROANCE wrrH RAILROAD COMMISmON OF
r7) TEXAS RULE 6.209 ALL-MIX PAMPA OPERATIONS SLANKET TO COVER REPLACBRETIRE TASKS: SERVICE 1.INES. PIPE 5 FEETT099 FEET OF LESS THAN 6 INCH DIAMETER. ANODES, METERS, REGULATORS AND METffi LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF
215.589 TEXAS RULE 8.209 PAMPA DPSRATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET T099 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, RSGULATORS AND METER LOOPS IN ACCORDANCE WITH RAILROAD COMMISSION OF
1.040 TEXAS RULS 8.209 PAMPA OPERATIONS BLANKET TD COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEE;T OF 1-ESS THAN 8 INCH DIAMETER, ANODES, METERS. REGULATORS AND M<TER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF
O Tl=XAS RULE 8,209
"""
98,539
46.864
PAMPA OPERATIONS BLANKET TO COVER REPLACEIRETlRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 IMCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WllH RAILROAD COMMISSION OF TSXAS RULE 8.209
HEREFORD OPERATIONS BLANKET TD COVffi REPLACE/RETIRE TASKS: SERVlCE UNES, PIPE 5 FEET TO 99 FEET Of LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209
HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LlNES, PIPE 6 FEET ro 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METSRS. REGULATORS AND METER LOOPS IN ACCCORDANCE WITfl RAILROAD COMMISSION DF r~s RULE 8.209
WTI< Add itian ~ Page 76 of 98
ALL-MIX
ALL-MIX
ALL-MIX
AU.-MIX
ALL-MIX
ALL·MlX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-20115
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TSXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY Dl::CE:MBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y DECEMBER • 2016
030 TEXAS DtvlSION SYSTEM INTEGRl1Y DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTSGRl1Y DECEMSER • 2016
oao TEXAS DIVISION SYSTEM INTEGRl1Y DECEMSl'R -2016
030 TEXAS DIVISiON SYSTEM INTEGRl1Y DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y DECEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y DECEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y SEPTEMBER· 2016
030 TEXAS DIVISION SYSTSM INTEGRl1Y SEPTEMBER - 2016
030 TEXAs DIVISION SYSTEM INTEGRITY DECEMBER y 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y SEPTEMBER· 2016
030 TEXAS DIVJSION SYSTEM INTEGRITY SEPTSMSSR - 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y SEPTEMBER • 2016
030 TEXAS DlVISION SYSTEM INTEGRl1Y DECEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER. - 2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1) COST
2936 030.35276 3,111,629 3,111,629
"937 030.35277 118 118
2938 030.35278 290,254 290,254
2939 030.35279 678 678
2940 030.35280 139,733 139,733
2941 030.35281 23,5'14 23,544
2942 030.35203 1,696,963 1,696,963
2943 030.352-136 1,263 1,263
2944 OJ0.35287 50,363 50,363
2945 030.352B8 529,145 528,145
2946 0'30.35289 32,083 32,883
2947 030.35290 391,2.62 391,262
2946 030.35291 45,147 45,147
"949 030.35292 1,943,501 1.943,501
2950 030.35293 79,418 79,418
2951 030.3:5294 750 750
2952 030.35295 1,185 1,165
2953 030.35296 363,096 3aa,09s
2954 030.35297 343,841 343,841
ATMOS. ENEJl:G'YCORPORATION, WEST TEXAS DMS~ON INTERIM COST RECOVER.Y ANO RAl'E ADJUSTMENT REPORT
PROJECT RE.PORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS OEOICJ\TED TO PU!ILIC USE IN CJ\LENOJ\R YEAR 2016 (2)
PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FE!OT Of LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE B.209
PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACEJRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF !.ESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND MHER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
BIG SPRING OPERATIONS BLANKET TO COVER REP!.ACE/RHIRE TASKS: SERVICE 1.INES. PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 8.209
BIG SPRING OPERATIONS BLANKH TO COVER REPLACEIRETIRE TASKS; SERVICE LINES, PIPE 5 FEH TO gg FEET OF l-ESS THAN 8 INCH DIAMETER, ANODES, MET!ORS, REGULATORS AND MHER lOOPS IN ACCCORPANCE WITH RAii.ROAD COMMISSION OF TEXAS RU!.E 8,209
SEMINDLEIBRDWNFIEl.D OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIP1' 5 FEH TO 99 FEET OF !.ESS THAN 8 l!>lCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RU!.E 8,209
SEMINOLEIBROWNFIEl.D OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET Of LESS THAN 8 INCH DIAMETER, ANOD!OS, METERS, REGULATORS AND METER !.OOPS IN ACCORDANCE WITH RAILROAD COMMISSION DF TEXAS RU!.E 8.209
LUBBOCK OPERATIONS BLANKET TO COVER REPLACEJRf:;TIRi:; TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET Of LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl-E 8.209
l-UBBOCK OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO gg FEET Of l.ESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSiON OF TEXAS RULE 8.209
LUBBOCK OPERATIONS BLANKET TO COVER REPl.ACEIRETIRE TASKS: SERVICE UNES, PlPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209
LITTLEFIELD OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.299
LffTLEFIELD OPERATJONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 8.209
PLAINVIEW OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCOROANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 8.209
PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMET!OR, ANODES, MET!ORS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TAsKS: SERVICE LINES, PIPE 5 FEET TO 99 FEH OF 1.ESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
AMARILLO OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF' u:;ss THAN a INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200
AMARILl.O OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS ~N ACCCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE B.209 PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 PAMPA OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF l.ESS THAN a INCH DIAMETER. ANODES. METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
WTX AddltlQn:; l'~ge77of98
CUSTOMERS BENEFITED
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
AL!.-MIX
ALL- MIX
1\1.!.-MIX
All-MIX
ALL-MIX
DJ\TE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRIJY SEPTEMBER - 201 S
030 TEXAS DIVISION SYSTEM INTEGRIJY DECEMBER- 2016
oao TEXAS DIVISION SYSTEM INTEGRIJY SEPTEMBER - 201$
030 TEXAS DIVISION SYSTEM INTEGRllY DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER- 201'6
030 TEXAS DIVISION SYSTEM INTEGRITY O~Cl::MBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMB!OR • 2016
O:lO TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2916
030 TEXAS DIVISION SYSTEM INTEGRIJY DECEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRIJY DECEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
LINE ALLOCATED NO. PROJECT NUMBER COST[11 COST
2955 030.35298 115 115
295"6 030.35300 644.666 £44,666
2957 030.35301 106 106
2956 030.35302 316.456 316.456
2959 030.35303 57,417 57,417
2960 030.35304 1,318,319 1.316.319
2961 030,:85305 1,567 1,567
2962 030.35306 413,551 413,551
298'3 0:30.35308 1ABB 1,488
2964 030.35309 484,034 464.034
2965 030.35310 920 920
2966 030.35320 3,793 3,793
2$87 030.35325 63.975 63,975
2968 03C.35411 339 339
2969 030.35412 20,478 20,478
2970 030.35448 3C2 302
2971 030.35452 104 104
2972 030.35455 694 SIM
2973 030.35462 46,666 46,666
2974 030.35466 48,778 48,778
2975 030.35466 748 748
ATMOS ENERGY COR:POJtA, TION, WEST TEXAS DIVIS~ON INTERIM COST RECOVERY AND RATE ADJUSTMENT Rf PORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 [21
PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS lljAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209
AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS lljAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACOCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
HEREFORD OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 6.209
HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITfl RAlLRoAD COMMISSION OF TEXAS RULE 8.209
PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACEJRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
!!IG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEl'T TO 99 FEET OF LESS THAN 8 INCH DIAMETER. ANODES, METERS. REGULATORS AND METER LOOPS IN ACCCOROANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO !l!l FEET OF LESS THAN 8 INCH DIAMETER. ANODES, METERS. REGULATORS AND METER LOOPS IN ACCCOROANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
SEMINOLE/BROWNFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCOROANCE WITfl RAlLROAD COMMISSION Of TEXAS RULE 8.209
SEMINO!.E/BROWNFIELO OPERATIONS !ILANKETTO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET Of LESS WAN B INCH DIAMETER. ANODES. METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 9.209
BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET Of' LESS lliAN a INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
AMARILLO OPERATIONS BLANKET TO COVER REPlACEJRETIRE TASKS: SERVJCE LINES, PIPE 5 FEET TO 99 FEET Of LESS lljAN 9 INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE El.209
HEREFORD OPERATIONS BLANKET TO COVER R<PLAC<:IRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF !.ESS IBAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDA.~CE WITH RAILROAD COMMISSION OF TEXAS RULE B,209
UTILE FIELD OPERAllONS BLANKET To COV<R REPlACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS. REGULATORS AND METER LOOPS IN ACCCOROANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPlACE 23 FEET DF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAlLROAD COMMISSION Of TEXAS RULE 8.209 RETIRE 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 10 FEET OF 4 INCH POLY MAIN AND RETIRE 10 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S.209
PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, Ml'TERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE UNES, PIPE 5 FEET To 99 FEET Of LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITfl RAILROAD COMMISSION Of TEXAS Fl.LILE 8.209
HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPES FEET TO 99 FEET OF LESS TflANB lNCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORD/\NCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.ioo
WTX Addll~on.s P.a:se 78 of98
CUSTOMERS BENEFITED
ALL·MJX
ALL- MIX
ALL-MIX
ALL· MIX
ALL· MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL.MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXJ\S DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAs DIVISION SYSTEM INTEGRITY SEPTEMBER~ 2016
030 Tl'XAS DIV1SION SYSTEM INTEGRITY DECEMBER M 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST~ 2016
030 TEXJ\S DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER-2016
030 TEXAS OIV!SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER· 2016
030 TE)l'.AS DIVISION SYSTEM IMPROVEMENTS DECEMBER -2016
030 TEXAS DIVISION SYSTEOM IMPROVEMENTS DECEMBER - 2016
LINE ALLOCATED NO. PROJECT NUM6ER CDST(1) COST
2976 o30.a5470 21MOS 218.406
2977 030.35471 50,723 50,723
2978 030.35472 859 859
2979 030.35474 204 204
2980 030.35489 127 127
2981 0311.35490 74 74
2982 030.35495 194 194
2983 030.35497 202 202
29/l4 O'l0.35503 155 155
29B5 030.35507 135 135
2986 030.35509 618 618
2987 030.36510 1,042 1,042
29B8 030.35511 74 74
2989 030.30512 4,133 4,133
2990 030_35513 70 70
2991 030.35514 6 B
2992 030.35515 2,282 2,282
2993 030.35525 187,193 187,193
2994 030.35526 316 318
2995 030.35527 380 380
2996 030.35528 1,133 1,133
2997 030,35566 19,066 19,066
ATMOS ENERG'i' CORPORAT~ON, WEST TEXAS OMSION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2018 (2)
PERMIAN BASIN OPERATIONS BLANl<ET TO COVER RS'LACEIRETIRE TASKS; SERVICE LINES, PIPE 5 FEET TO 99 FEET Of LESS WAN B INCH DIAAIETER. ANODES, METERS, REGUl-ATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLJU'' 8.209
BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS; SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGLJLATORS AND METER LOOPS IN ACCCORDANCE WIW RAILROAD COMMISSIO>l OF TEXAS RULE 8.209
SEMINOl-E/l!ROWNFIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE o FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES. METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH R/>JLROAD COMMISSION OF TEXAS RULE 8.209
AMARIU.O OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE l>FEET TO 99 FEET OFLESS WAN 8 INCH DIAMETER. ANODES, METERS, REGLJLATORS AND METER LOOPS IN AcCcORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
LLI!ll!OCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS; SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER. ANODES, METERS, REGULATORS ANO METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF T~AS RULE 8,209 PAMPA OPERATIONS BLANKET TD COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCDRDANCE WITH RAILROAD COMMJSSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEETT099 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH R/>JLROAD COMMISSION OF TEXAS RULE 8.209 PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER. ANODES. METERS, REGULATORS /\ND METER LOOPS IN /\CCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
LllBBOCK OPERATIONS BLANKET TO COVER R!OPLACEIRETIRE TASKS: SERVICE LINES, PIPE5 FEET TO 99 FEET OF LESS WAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8,209
PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMlSSlON OF TEXAS RULE 8.209
AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEETTD 99 FEET OF LESS THANB INCH DIAMETER, /\NODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION DF 1EXAS RULE 8-20:9 PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LlNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, /\NODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.209
HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERV!CE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN l\CCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
B!G SP.RING OPERATIONS BLANKET TO COVER REPLACEIREflRE TASKS: SER~CE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMJSSION OF TEXAS RULE B.209
SEMINOLEIBROWNFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS; SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACOCDRDANCE WITI-1 RAILROAD COMMISSION OF TEXAS RULE 8_209
PERMIAN BASIN OPERATIONS BLANKET TD COVER REPLACEIRETrRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS lN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209
LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET DF LESS THAN 6 lNCM DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH R/>JLROAD COMMISSJON OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 327 FEET OF 4 INCH POLY MAIN /\ND RETIRE 327 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 INSTALL 3276 FEET OF 2 INCH POLY MAIN AND 90 SERVICES AND RETIRE 3276 FEET OF 2 INCH STEEL MAIN AND 90 SERVICES IN ACCORDANCE WIW RAILROAD COMMISSION OF TEXAS RULE B.209
wrx Addi1lon5 Page 79 of93
CUSTOMERS BENEFITED
Al-L-MIX
ALL-MIX
All-MIX
All-MIX
All-MIX
Al-L- MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MlX
All-MIX
Al-L- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
Al-L-MIX
ALL-MIX
DAT<. PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAS DJVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER ~ 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OECEMBER-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER· 2016
030TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER • 2'016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2010
030 TEXAS DMSION SYSTEM lMPROVEMENTS SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEM~ER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS OIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2<l16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1J COST
2998 030.35588 285 285
2999 030.30598 233 233
3000 030.35600 531 531
3001 030.35603 314 314
3002 OJ0.35609 1,725 1,725
3003 030.35610 478 478
3004 01!0.35611 342 342
300:5 030.35619 446 446
3006 0'30,35620 407 407
3007 030.35622 694 094
3008 030.35623 451 451
3009 030.35624 599 599
3010 030.3562B 3,341 3,341
3011 o:m.35637 149 149
3012 030.35644 85 85
3013 030.30045 330,518 330,518
3014 030.35648 99 99
3015 030,35659 559 559
3016 030.35660 814 814
1!017 01ID.J5664 44,767 44,767
3018 030,3fiB65 14.419 14,419
3019 030.35666 2,349 2,349
3020 030.35666 147 147
3021 030,35671 4,681!3 4,686
3022 030.35873 137 '!37
3023 030.35777 3,690 3,890
3024 030.3<;114 33 33
3025 030,3<;118 17.721 17.721
3026 030.36120 15,504 15,504
3027 030.36123 83 83
3026 030,36124 1,052 1,052
3029 030.36133 794 794
3030 030.36151 1,250 1,250
ATMOS ENERGY CDRPOMllON, WESTTEXAS DIVISION INTERlM CO:S.T fl:ECOVERVAND RAl'f APJU:S.TMENT REPORT
PROJECT REPORT CT 2016
DESCRIPTION OF COMPLC.iED PROJECTS D~DICATED TO PUBLIC ·usE IN CALENDAR YEAR 2016 (2)
REPLACE 17 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 13 FEET OF 2 INCH POLY MAIN AND RETIRE 13 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 10 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF llEXAS RULE 8.209 INSTALL 460FEET DF2 INCH POLY MAIN AND RETIRE 460 FEET OF 2 INCH STEEL MAIN ANO REPLACE 10 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 45 FEET OF 2 INCH STEEL MAIN AND I SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 1 4 INCK WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE 5 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE 9 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 136 FEET OF 4 INCH AND SB FEET OF 2 INCH POLY MAIN AND RETIRE 194 FEET OF 3 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WJTH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 93 FEET OF 2 INCH POLY MAIN AND RETIRE 93 FEET OF 2 INCH STEEL MAIN AND REPLACE 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RELOCATE 34 FEET OF2 INCH SllEEl. MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 lNST ALL 497 FEET OF 2 INCH POLY MAIN AND 12 SERVICES AND RETIRE 495 FEET OF 2 INCH STEEL MAIN AND 12 S'ERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8,209
REPLACE 5 FEET OF2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCEWlTH RAILROAD COMMISSION OF TEXAS RULE 8.209
LITTLEFIELD OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS lN ACCCORDANCE W!TH RMLROAD COMMISStON OF TEXAS RULE 8.209
LUBBOCK OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 33 FEET OF 4 INCH POLY MAIN AND RETIRE 33 FEET OF 4 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL206FEETOF2 INCH POLY MAIN AND RETIRE 206 FEET OF 2 INCH STEEl MAIN AND REPLACE 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL284 FEET OF2 INCHPOLY MAIN AND RETIRE 284 FEET OF 2 INCH STEEL MAIN AND REPLACE 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_2.0:9 INSTALL 8570 FEET OF 2 INCH POLY MAIN AND 12SSERVICES AND RETIRE 8570 FEET OF 2 JNCH STEEL MAIN AND 126 SERVlCES lN ACCORDANCE WITH .RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 20029 FEET OF 2 INCH POLY MAIN AND RETIRE 20029 FEET OF 2 INCH PLASTIC IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 603 FEET OF 2 INCH POLY MAIN AND 17 SERVICES AND RETIRE 603 FEET OF 2 JNCH STEEL MAIN ANO 17 SERVJCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALi- 710 FEET OF 1.25 INCH POLY MAIN AND 11 SERVICES AND RETIRE 281 FEET OF 2 INCH STEEL MAIN AND 11 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 667 FEET OF 21NCH POLY MAIN AND RETIRE 128 FEET OF 3 INCH AND 535 FEET OF 2 INCH STEEL MAIN AND REPLACE 12 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPl-ACE 45 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 9550 FEET OF 2 INCH POLY MAIN AND 20 SERVICES ANO RETIRE 9550 FEET OF 2 AND 4 INCH STEEL MAIN AND 20 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 7400 FEET OF 4 INCH POLY MAIN AND 6 SERVICES AND RETIRE 7400 FEET OF 2 INCH PLASTIC MAIN At<ID 6 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL600 FEET OF 2 INCH POLY MAIN AND RETIRE 600 FEET OF 2 INCH STEEL MAIN AND REPLACE 9 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 287 FEET OF 4 INCH POLY MAIN ANO RETIRE 287 FEET OF 4 INCH STEEL MAIN A~D REPLACE 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISS!ON OF TEXAS RULE 8.209 INSTALL 260 FEET OF 4 INCH POLY MAIN AND RETIRE 260 FEET OF 4 INCH STEEL MAIN ANO REPLACE 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTXAdditions Page BO Qf9S
CUSTOMERS BENEFITED
ALL- MIX
ALL-MIX
ALL-MIX
ALL- MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
All-MIX
ALl-·MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-M~
DATE PLACEu IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2.016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
01!0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
01!0 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSllEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSllEM INTEGRITY MAY-2016
030 TEXAS DJVISION SYSTEM INTEGRITY MAY-2oi6
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INllEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 llEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
01!0 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201"
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRllY MAY~2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY·201B
030 TEXAS DIV!SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSllEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
030 TEXAS DIVISION SYSTEM INllEGRITY MAY-2016
030 TEXAS DMSlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST{\) COST
3031 030.315153 36,2.43 36,243
3032 030.36172 1,S72 1.572
3033 030.36173 69 69
3034 030.36177 2,298 2,298
3035 030.36180 1.110 1,110
3036 030.36202 14 14
3037 030.36203 171 177
30JB 030.36204 92 92
3039 030.36205 B9 69
3040 030.:J6206 142 142
3041 030.36211 65 65
3042 030.36223 5,697 5.697
3043 030.36233 1,947 1,947
3044 030.36260 610 610
3045 030.36261 75 75
3046 030.36266 2,386 2,388
3047 030.362157 70,633 70,633
3048 030.36289 21S 215
3049 030.36298 2.113 2.113
3050 030 . .36301 68.051 68,051
3051 030.36315 5,182 5,182
3052 030.36327 9'l6 996
3053 030,315328 40 40
30S4 030.36330 912 912
3055 030.36335 1,774 1.774
306'! 030.36343 515 515
3057 030.36349 54 S4
3058 030.'l6354 178 17B
3059 030.36372 2,450 2,450
3000 030.36384 795 795
3001 030.38397 51 51
3002 030.36414 91 91
3003 030.:J6446 2,8S4 2,854
:Ml64 030.:J6447 84 84
3065 030.:J6449 4S8 458
:Ml66 030.36450 92 92
3067 030.36473 3,989 3,!189
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION INTERIM COST RECOVERY AND RATE ADlUSTMENT REPORT
PROJECT R.EPOR.T CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2015 [2)
INSTALi. 7740 FEET OF 2 INCH POLY AND 870 FEET OF 4 INCH POLY MAIN AND 238 SERVICES AND RETIRE 7740 FEET OF 2 INCH STEEL MAIN AND 870 FEET OF 4 INCfl STEEL MAIN AND 238 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALi. 516 FEET OF 4 INCH POLY MAIN AND RETIRE516 FEET OF 3 INCH STEEL MAIN IN. ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 1 INCH SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 6'l FEET CF 4 INCH POLY MAIN AND RETIRE 66 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 266 FEET OF 4 INCH POLY MAIN AND RETIRE 230 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 1 SERVICE IN ACCORDANCE WlTH RAILROAD COMMISSION Of TEXAS RULE 8.209 RETIRE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of"TE:XAS RULE 8.209 RETIRE 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 3661 FEET OF 3 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 4323 FEET OF 2 INCfl PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 4250 FEET OF 2 INCH POLY MAIN AND RETIRE 4250 FEET OF 2 INCH PlASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 120 FEET OF 4 INCH POLY MAIN AND RETIRE 120FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF Tl'XAS RULE 8.209 INST ALL 120 FEET DF 2 INCfl POLY MAIN AND RETIRE 120 FEET OF 2 INCH STE.EL MAIN IN ACCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RULE 8.209 INSTALi. "4 FEET OF 4 INCH AND 24 FEET OF 2 INCH POLY MAIN AND RETIRE 84 FEET OF 4 INCH AND 24 FEET OF 2 INCHS STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE8.2.09 INSTALL 183 FEET OF 4 INCH POLY MAIN AND 4 SERVICES AND RETIRE 183 FEET OF 3 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 18BO FEET OF 4 INCH AND2000 FEET OF2 INCH POLY MAIN ANO RETIRE 3880 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TEXAS RULE 8.209 ISNTALL 134 FEET OF 2 INCH POLY MAIN AND RETIRE 532 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 432 FEET OF 2 INCH POLY MAIN AND 5 SERVICES AND RETIRE 432 FEET OF 2 lNCH STEEL MAIN AND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUlE 8.209 INSTALL B520 FEET OF 2 INCH POLY MAIN AND 171 SERVICES AND RETIRE B8B5 FEET OF 2 INCH Pl.ASTie MAIN AND 171 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALl220 FEET OF 4 INCH POLY MAIN AND RETIRE 1760 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 305 FEET OF2 INCH POLY MAlNAND 2SERVICESAND RETIRE 305 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 206 FEET Of 4 INCH POLY MAIN AND 6 SERVICES AND RETIRE 206 FEET OF 3 INCH STEEL MAIN ANO 6 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 780 FEET OF 1.25 INCH POLY MAIN AND 3SERVICES AND RETIRE 7BO FEET OF 2 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 100 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 57 FEET OF 2 INCH AND 99 FEET OF 1.25 INCH POLY MAIN AND RETIRE 156 FEET OF 2 !NCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD CDMMISSIDN OF TEXAS RULE 8.209 INSTALL 421 FEET OF 21NCH AND116 FEET Of 1.25 INCfl POLY MAIN AND 6 SERVICES AND RETIRE 545 FEET OF 2 INCH STEEL MAIN AND 6 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REBUILD 6M ROOTS METER SETTING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRED TWO 1 INCH STEEL SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.20S INST ALL 535 FEET OF 2 INCH POI. Y MAIN AND RETIRE 345 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 3M ROOTS METER AND REGULATOR VAL VE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 1 SERVICE AND RETIRE 5 SERVICES IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL94B FEET OF 2 INCH POLY MAIN AND24SERV!Cf:;S AND RETIRE 946 FEET OF 2 INCH STEEL MAIN AND 24 SERVICE;S IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTXA.ddittons Pi!tl!;-1:! 81-of 98
CUSTOMERS BENEFITED
ALL· MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MlX
ALL-MIX
ALL-MIX
ALL-MIX
ALl.-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALl.-MIX
ALl.-MIX
ALl.-MIX
ALI.- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE P~~·D IN GAS PLANT JN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DJVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
O:Ml TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
O:Ml TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
0'30 TEXAS DIVISION SYSTEM IMPROVEMENTS MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAYn2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEFTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM !MPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY.2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE Atl.OCATED NO. PROJECT NUMBER COST(11 COST
3Q68 030.36474 10,271 10,271
3069 030.36480 52,133 52,133
3070 030.36482 47,658 47,656
3071 030.36483 214,693 214,693
3072 030.36004 28 26
3073 030.36506 463 463
3074 030.36514 54 o4
3075 030.38517 54 54
3076 030.38545 1,059 1.009
3077 030,36546 12.731 12,731
3078 030.38562 123 123
3079 030.36575 1,323 1.323
3080 oao.36576 3.768 3,768
3081 030.36086 102 102
3082 030.3651i19 73 73
3083 030.36634 38,273 38,273
3084 030.38664 2,121 2,121
3085 030.3666B 571 571
3086 030.36669 736 738
3067 030.36686 4,342 4,342
30H8 030.36687 4,155 4,155
3oa9 030.36690 4,036 4,036
3090 030.36692 3,430 3,430
3091 030.36893 3,842 3,842
3092 030.3B694 3,551 3,551
3093 030.:36695 4,343 4,343
3094 030.::36696 4,579 4,579
3095 030.36697 4,o47 4,547
30.96 030.36698 4,201 4,201
3097 030.38699 4.017 4,517
309B 030.36700 4,652 4,662
3099 030.36701 4,555 4,566
3100 030.39702 4,119 4.119
3101 030.36703 1,379 1,379
3102 030.36704 4,207 4,207
3103 030.36705 4,394 4,384
3104 030.36706 4,193 4.193
3105 030.36707 4,253 4,253
3106 030.36706 3,692 3,592
3107 030.36709 2,008 2,86B
3106 030.36710 4,213 4,213
3109 030.36711 4,494 4,494
3110 030.36712 4,406 4,406
ATMOS ENERGYCORPORATION, WESTTEXAS DIVISION INTERIM COST RECOVERY ANO MTE ADJUSTMENT REPORT
PROJECT REPORT CV l016
OESCRIPTION Of COMPLETED PROJECTS OEOIGATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INST ALL 10225 FEET OF 2 INCH POLY MAIN AND RETIRE 10225 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 10000 FEET OF 2 INCH AND 4 1NCH POLY MAIN AND RETIRE 10000 FEET OF2 AND4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 10000FEET OF2 AND4 INCH POLY MAIN AND RETIRE 10000 FEET OF 2 AND 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 10000 FEET OF2, 4, AND6 INCH POLY MAIN, 2 RECTIFIERS, AND 1 REGULATOR STATION AND RETIRE 10000 FEET OF 2, 4, AND 6 INCK STEEL MAIN, 2 RECTIFIERS, AND 1 REGULATOR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 RETIRE 1 SERVICE IN ACCORDANCE WIT!l RAILROAD COMMISSION Of TEXAS RULE a.209 INST ALL 405 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 405 FEET OF 3 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISS10N OF TEXAS RULE S.209 RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAlLRDAD COMMISSION OF TEXAS RULE 8.209 REBUILD LARGE VOLUME METER SETTING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTAU-4000 FEET OF 2 INCH POLY MAIN AND 9 SERVICES AND RETIRE 7650 FEET OF 2 INCH STEEL MAIN AND 9 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF Tl'XAS RULE 8.209 INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCO.RDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL26SO FEET OF 1 INCH POLY SERVICE LINE AND RETIRE 2690 FEET OF 2 INCH PLASTIC SERVICE LINE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 188 FEET OF 4 INCH POLY MAIN AND 2 SERVICES AND RETIRE 188 FEET OF 4 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.200 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 2 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 2202FEET OF 4 INCHAND 7657FEETOF2 INCH POLY MAIN AND 167 SERVICES AND RETIRE 98o9 FEET OF 3, 4, AND 6 INCH STEEL MAIN AND 167 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 806 FEET OF 4 lNCH POLY MAIN AND 4 SERVICES AND RETIRE SOB FEET OF 3 INCH STEEL MAlN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 RETIRE 44,856 FEET OF 3 INCH ABS DUE TO SYSTEM INTEGRITY IN ACCORDANCE WlTH RAILRAOD COMMISSION OF TEXAS RULE 8.209 INSTALL 197 FEET OF 4 INCH POLY MAIN AND 5 SERVICES AND RETIRE 197 FEETOF3 INCH STEEL MAIN AND 58ERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF H'XAB RULE 6.209 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE DEE;PWELL IN ACCORDANCE WITH Rl\ILRDAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELl IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELl IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S.209 REPLACE DEEPWEll IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELl IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REFLACE DEEPWELL IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8,209 REFLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8-209 REPLACE DEEPWELL IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE B.209 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE DEEPWELL IN ACCORDANCE WITl-I RAILROAD COMMJSSION OF TEXAS RULE 8.2Q9 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWElL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B,209 REPLACE DEEPWELL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WIX Additions Filge82 of9-8
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL· MIX
All-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL- MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
All-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2018
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY NOVEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRfTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DMSION PUBLIC IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-201fl
030 TEXAS DIV1SION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM (NTEGR1TY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRrTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
oao TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IN1EGRl1Y MAY-2018
030 TEXAS DIVIStON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVIS!ON SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST[1) COST
3111 030.35715 3,012 3,012
3112 030.36723 5,524 5.524
3113 030,36724 2,671 2,871
3114 030.36725 2,963 2,963
3115 030.36733 10 10
3116 030.36739 67 67
3117 030,36741 263 263
311B 030.36743 14 14
3119 030.36744 15 15
3120 030.3'!749 10 10
312'! o:m.:36750 53 53
3122. 030.36754 37 37
3123 030.3'!757 1,237 1,237
3124 030.36756 7 7
3125 030.36759 97 97
3126 030.36761 100 100
3127 030.36778 980 980
3128 030.3"762 126 128
3129 030.367B4 117 117
3130 030.36785 685 685
3131 030.36786 1,703 1,703
3132 030_36787 101 101
3133 030.36795 86 BS
3134 030.36796 146 146
3135 030.3'!603 635 635
3136 030.35817 77 77
3137 OJ0.36818 117 117
3138 030.36625 2,010 2,010
3139 030,313834 1.149 1.149
3140 0:30,3B838 39 39
3141 030.36643 1,204 1,204
3142 030.36647 3,973 3,973
3143 030.36655 603 603
3144 030.3665a 133 133
3145 030.36659 108 108
3146 030.36000 159 159
3147 0'30.36866 8.897 B,897
3146 030.36873 4,057 4,057
AlMOS ENERGY CORPORATION, WEST T£XAS DIVISION ll>lfl'RIM COST RECOVERY AND RAT< ADJUSTMENT REPORT
PROJECT REPORT CV 2016
Dl!SCRIP'rlON Ot=: COMPLETEO i!J'ROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 j2)
INSTALL 1475 FEET OF 2 INCH POLY MAIN ANO 18 SERVICE AND RETIRE 1475 FEET OF 2 INCH STEEL MAIN AND 18 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE AND RELOCATE FACILITIES: INSTALL 1624 FEET OF 4 INCH POLY MAIN, 30 FEET OF 2 INCH POLY MAIN AND RETIRE 1620 FEET OF POLY MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 133 FEET OF 2 INCH POLY MAIN AND 4 SERVICES AND RETIRE 133 FEET OF 2 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 6.209 INST ALL 242 FEET OF 2 INCH POLY MAIN AND 4 SERVICES AND RETIRE 242 FEET OF 2 INCH STEEL MAIN AND 4 SERVIC~S IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 RETIRE 2 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE Will-I RAILROAD COMMISSION OF TEXAS RULE B.20.9
RETIRE 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 6.2!lB INSTALL 300 FEET OF 21NCH POLY MAIN AND RETIRE663 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
RETIRE 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B,209 RETIRE 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
RETIRE 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 iNSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 6.209
INSTALL 1BO FEET OF 2 INCH POLY MAIN ANO RETIRE 180FEET OF 2. lNCH POLY MAIN AND 585 FEET Of 4 INCH STEEL MAIN ANO 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANC!O WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 160 FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL227 FEET OF 2 INCH POLY MAIN /\NDRETIRE227FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 3 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REBUILD METER SETTING DUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.2.09 INSTALL3BO FEET OF 1.25 INCH POLY MAIN AND RETIRE 3BO FEET OF 2 INCH PLASTIC MAIN IN ACCOR!JANCEWlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 230 FEET OF 2 INCH POLY MAIN AND RETIRE 631 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 20 FEET OF 2 INCH STEEL MAIN JN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
RETIRE 1 SERVtCE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD METER SETTING AND REGULATOR OUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RELOCATE 566 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 566 FEET OF 2 INCH POLY MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 190 FEET OF 2 INCH STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2Q9
RETIRE 1 SERVICE DUE TO SYSTEM INT!OGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INST Al.L LARGE VOLUME METER SETTING DUE TO SYSTEM IMPROV!OMENTS IN ACCORDANCE WITH RAILRAOD COMMISSSION OF TEXAS RULE 6.209 INSTALL 1505 FEET OF 2 INCH POLY MAIN AND 9 SERIVCES ANO RETIRE 1605 FEET OF 2 ~NCH STEEL MAIN AND 9 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 IN SAUL 110 FEET OF 2 INCH POLY MAIN AND RETIRE 110 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WJTH RAllROAD COMMISSION Of TEXAS RULE 8.209 INST ALL WELDDVER IN ACCORDANCE WITH RAILROAD COMMJSSION OF TEXAS RULE B.209 REPLACE 22 FEET OF 2 INCH STEEL MAIN ll'l ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INST ALL 4530 FEET OF 2 INCH POLY MAIN AND 7 SERVICES AND RETIRE 4530 FEET OF 2 INCH STEEL MAIN AND 7 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTAUL 271 FEET OF 4 INCH POLY MAIN AND 8 FEET OF 2 INCH POLY MAIN AND RETIRE 271 FEET OF 4 INCH /\NO 8 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
WTX Additions P;aige83 Qf98
CUSTOMERS BENEFITED
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
/\LL-MIX
ALL-MIX
Al.L-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
A\.L-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN
GAS PLANT IN LOCATION PURPOSE OF PROJECT SERVICE
o;io TEXAS DIVISION SYSTEM INTEGRITY MAY-2Q16
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTE;GRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030TEXAS DIVISION SYSTEM !NTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY ·2016
030 TEX/IS DIVISION SVSTEM INTE;GRflY MAY-2016
030 TEX/IS DIVISION SYSTEM INTEGRflY MAY-2016
030 TEXAS DlVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPT<;MBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIYlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIYlSION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS OIVlSION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRlTY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2"16
030 TEXAS DlVISION SYSTEM IMPROVEMENTS MAY·2!l16
030 TEXAS DIViSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
o:m TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DlVISION SYSTEM INTEGRITY JUNE.2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COST(1) COST
3149 OJ0.36874 177 177
3150 030.36676 40,272 40,272
3151 030.36884 39 39
3152 030.36888 3,713 3.713
3153 030.36911 15,347 15,347
3154 030.38915 181 181
3155 030.36916 2,409 2,40•
3156 030,36925 86 86
3157 030.36930 48,196 48.196
3158 030.36934 118 118
3159 000.36935 27,929 27,929
3160 030.36957 56 56
3161 030.36959 39 39
3162 030.36963 4.383 4,383
3163 030.3'696'8 9,959 9,959
3164 030.35971 61,277 61,Zll
3165 030.35978 8,545 6,545
3166 030.37000 88 88
3167 030.37078 4,304 4,354
3168 030.37000 195 195
3169 030.37137 155 155
3170 030,37140 35,276 35,276
3171 030.37145 156 156
3172 030.37147 20,477 20,477
3173 030.37163 167 167
3174 030,37173 32,589 32,589
3175 030.37174 1,345 1,345
3176 030.37175 56 5fl
3177 030.37178 1,766 1.766
3178 030,37184 241 241
3179 030.37198 1,909 1,909
3180 030.37197 4 4
:i101 030.37198 69 69
3182 030.37209 2,506 2,505
3183 030.37213 100 .100
3104 030,37214 57 57
AiMOS ENE.filGY C:O~PORATION, WEST TEXAS OIVISION INTERIM COST RECOVERY AND RA.TE ADJUSTMENT RE PO FIT
PROJECT REPORT CT 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
RETlRE 1 SERVtC;J:: IN ACCORDANCE WITH RAILROAD COMM!SSION OF TEXAS RULE 8.209 !NSTALL890FEET OF 4 INCH POLY MAIN AND 10,900 FEET OF2 lNCH PLOY MAIN AND 240 SERVICES AND RETIRE 890 FEET OF 4 lNCH STEEL MAIN, 640 FEET OF 3 INCH STEEL MAIN, 8760 FEET OF 2 INCH STEEL MAIN AND 1055 FEET OF 2 INCH POLY DUE IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE 8.209
RETIRE 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTA!.L 300FEET OF2 INCH POLY MAIN ANO RETiRE 300 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILRDAO COMMISSION OF TEXAS RULE 8.209
INST Al.L 1750 FEET OF 2 INCH POLY MAIN AND 43 SERVICES AND RETIRE 1750 FEET OF 2 INCH STEEL MAIN DUE IN ACCORDANCE WITH RAILROAD COMMISSION CF TEXAS RULE B.209 RETIRE 154 FEET OF 2 INCH POLY IN ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 8.2.09
INST ALL 325 FEET OF 2 INCH POLY MA1N AND 8 SERVICES AND RETIRE 325 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 10,888 FEET OF 2 INCH POLY MAIN WITH 134 SERVlCES AND RETlRE 2 INCH STEEL MAIN tN ACCORDANCE WITH RAiLRAOD COMMISSION OF TEXAS RULE 8.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 3,997 FEET OF 4 INCH POLY MAIN. 5,822 FEET OF 2 INCH POLY MAIN AND 146 SERVICES AND RETIRIO 9,819 FEET OF STEEL MAIN IN ACCORDANCE WITH RAl!.ROAD COMMISSION OF TEXAS RULEB.209
RETIRE 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
RETIRE 1 SERVICE DUE TD SVSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 3 INCH STEEL MAIN, RETIRE 3 INCH STTEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 3700 fEET OF 2 INCH POLY MAIN Wini 15 SERVICES AND RET!RE 3700 FEET OF 2 INCH EGGSHELL PIPE IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE 8.209 INST ALL 10626 FEET OF 2 INCH POLY MAIN AND 8206 FEET OF 4 INCH POLY MAIN AND 5 SERVICES, RETIRE 5 M!LES OF ABS AND STEEL MAINS IN ACCORDANCE WITH RAILRDAO COMMISSION OF TEXAS RULE 8.209 INSTALL3500 FEET OF 1 INCH POLY MAIN, RETlRE 3500 FEET OF 4 INCH STEEL MA!N IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 . 75 INCH STEEL SERVlCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUlLD REGULATOR STATION JN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 160 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 INCH STEEL SERVICE IN ACCORDANCE WffH RA!LROAD CDMMISSlONOFTEXAS RULE 8.209 INSTALL 7367 FEET OF 2 INCH PLOY MAIN AND 64 SERVlCES AND RETIRE 7367 FEET OF STEEL PIPE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
RETIRE 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 3800 FEET OF 2 INCH POLY MAIN AND 40 SERVICES AND RETIRE2860 FEET OF 3 INCH, 1200FEET OF2 INCH, AND 108 FEET OF 1.25 INCH ANO 40 SERVICES IN ACCORDANCE WITH RAILROAD COMMISS!ON OF TEXAS RULE 8,209 INSTALL317 FEET OF 2 IN POLY MAIN A.~DASSOCIATED SERVICES AND RETIRE 317 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200 INSTALL6641 FEET OF 2 INCH PO!.Y MAIN, 1669 FEET OF 4 INCH POLY MAIN AND 200 SERVICES AND RETIRE 6510 FEET OF VARIOUS STEEL MAIN IN ACCORDANCE WITH RAILROAO COMMISSION OF TEXAS RULE 8.209 INST ALL 288 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRED 232 FEET OF 2 INCH STEEL MAIN, 111 FEET Of 2 INCH PLOY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S,2.09 RETIRE 5<J FEET OF 1.25 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAO COMMISSION DFTEXAS RULE 8.209 INSTALL 500 FEET OF 2 INCH POLY MAIN AND RETIRE 500 FEET OF 2 INCH PVC IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE 8.209 RETIRE 175 FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE S.209 INSTALL 860FEET OF 2 INCHPOLY MAIN AND RETIRE 860 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 .RETlRE 1 STEEL SERVICE DUE TO SYSTEM lNTEGRl1Y IN ACCORDANCE WITH RAILROAD COMMISSION OF lEXAS RULE 8.209 INSTALL 7 FEET Of .75 INCH POLY AND RETIRE 7 FEET OF 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE B.209 INSTALL 153 FEET OF 2 INCH POLY MAIN AND 4 SERVICES AND RETIRE 153 FEET OF STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMMISSSION OF TEXAS RULE 8.209 RETIRE 2 STEEL SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL . 75 INCH POLY SERVICE AND RETIRE 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX Additions Page34of9.B
CUSTOMERS BENEFITED
ALL-MIX
A!.L-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
Al.L- MIX
Al.L- MIX
A!.L-MIX
Al.L·MIX
ALL-MIX
ALL-MIX
ALL-MIX
/\LL-MIX
AL!.-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
Al.L-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
Al.L-MIX
A!.L-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DAfE ......... CEOIN GAS PLANTIN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER- 2016
!
000 TEXAS DIVJSION PUBUC IMPROVEMENTS MAY-2016
000 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER~ 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DJVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY -2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRITY JUNE~2015
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVlSION PUBLIC IMPROVEMENTS MAY-2016
030 TEXAS DIVlSIDN SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM lNTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY SEPTEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXAS DMS]ON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRJTY MAY-2016
0'30 TEXAS DIVJSION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAV-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030TEXAS DIVISION SYSTEM INTEGRJTY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVlSIDN SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRllY MAY-2016
LINE ALLOCATED NO. PROJECT NUMBER COSTj1) COST
3165 oao.37216 57,543 57.543
3186 030,372.18 20 20
3187 030.37231 55 55
3188 030.37247 44 44
3169 000.37284 868 668
3100 030.37295 30 30
3191 030.37307 10,267 10,267
3192 030.37345 128 128
3193 030.37351 694 694
3194 030.37354 601 601
3195 aao.37367 32 32
3196 030.37369 1,481 1.481
3197 030.37370 14 14
3198 030.37374 35,550 35,550
3199 Oa0.373~9 51 51
3200 030.37391 55 55
3201 030.37394 1,612 1.612
3202 030.37397 73 1a
3203 030.37407 1,861 1,661
3204 030.37432 5,929 5,929
3205 030.37474 10.176 10,176
3206 030.37498 174.649 174,649
3207 030.37503 42.056 42,056
320B 030.37510 155 155
3209 030.375~ 73 7a
3210 o:m.37521 !16 96
3211 030.37530 43 43
3212 030.37539 4,174 4,174
3213 030.37643 111 111
3214 030.37544 3,877 3,877
3215 030.37572 2,615 2,615
3216 030.37594 808 808
3217 000.37608 2,047 2,047
3218 030.37612 787 787
ATMOS ENERGYCORPORAT~ON, WfSl'TEXAS DIVISION INTERIM COST RECOVERY AND RA.TE ADJUSTMENT REPORT
PROJECT R:EllOR'f CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR VEAR 201612)
INST All26,366 FEET OF 6 INC!l STEEL MAIN AND RETIRE 26,386 FEET OF STEEL MAIN DUE TO SYSTEM INTEGRl"!Y IN ACCORDANCE WIT!1 RAILROAD COMMISSION OF TEXAS RULE S.209 RETJRE 3 STEEL SERVICES DUE TO SYSTEM INTEGRl"!Y IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRl"!Y IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 287 FEE OF 2 INCH POLY MAIN ANO ASSOCATED SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCOROANCE WITH RAILROAD COMMISSION OF TEXAS RU!.E 8.209 RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RA~L.ROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 1535 FEET DF2 ~NCH POLY MAIN, 755 FEET OF 4 INCH POLY MAIN AND RETIRE 945 FEE OF 8 lNCH STEEL MAIN, 210 FEET OF 6 INCH STEEL MAIN, 1905 FEET OF 3 INCH STEEL MAIN AND 75 FEET OF 4 !NCH STEEL MAIN IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REBUILD LARGE VOLUME METER QUE TO SYSTEM IMPROVEMIONTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD METER SETTING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 10 FEET OF 2 INCH STEEL MAIN AND 2 INCH DRESSER COUPLING AND RETIRE 1 O FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.209 INSTALL500 FEET OF 2 INCH POLY MAIN AND RETIRE 500FEET OF 2 INCH PVC IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 INCH STEEL SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL4326 FEET OF 21NCH POLY, 2965 FEET OF 4 INCH POLY WITH 117 SERVICES AND RETIRE 4536 FEET OF 2 INCH PVC, 743 FEET OF 2 INCH STEEL MAIN AND 1989 FEET OF 3 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 350 FEET OF 4 INCH POLY MAIN WITH 4 SERVlCES AND RETIRE 350 FEET OF 3 INCH STEEL MAIN lN ACCORDANCE WffH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVlcE DUE TO SYSTEM INTEGRl"!Y IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL a13 FEET OF 2 INCH POLY MAIN WITH 8 SERVICES AND RETIRE 313 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE 8.209 INSTALL 357 FEET OF 4 INCH POLY MAIN, 20 FEET OF 2 INCH POLY MAIN AND RETIRE 345 FEET OF 4 INCH STEIOL, 10 FEET OF 3 INCH STEEL MAIN AND 1 O FEET Of 2 INCH STEEi. MAIN IN ACCORDANCE WIT!1 RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 1009FEETOF6 INCH AND 503 FEET OF 1.25 INCf-I POLY MAIN AND 3 SERVICES AND RETIRE 663 FEET OF 4 INCH AND 6 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE W!TH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 28.800 FEET OF 12 INCH STEEL MAIN AND RETIRE 28,800 FEET OF 15 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 3SOOFEET OF 16 IN STEEL MAIN AND RETIRED3600 3 INC!l STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE B7 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 1 STEEL SERVlCE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209
RETIRE 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WIT!l RAILROAD COMMISSION OF TEXAS RULE 8.209 INST All 3195 FEET OF 2 INCH POLY MAIN, 5028 FEET OF 1.25 INCH Pol Y WITH 2 SERVICES AND RETIRE 24.550 FEIOT OF 2 lNC!l PVC MAIN IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE 8,209 RETIRE 95 FEET OF 3 INCH STEEL MAIN lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1272 FEET OF2 INCH POLY MAIN AND RETIRE 1272 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 300 FEET OF 2 INCH POLY MA!N AND RETIRE 300 FEE:;T OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD GOMMISSJON OF TEXAS RULE fl.2.09 REPLACE METER AND RIOGULATION COMPONENTS IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD LARGE VOLUME METER DUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 25 FEET OF 2 INCH STEEL MAIN WITH SERVICE AND RETIRE 25 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8,209
WfXAddUions Page SS of98
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MJX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
All-MIX
All· MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
All-MIX
ALl-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
UAJ<.PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRl"!Y OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl"!Y MAY-2016
030 TEXAS DIVISION SYSTEM !NTEGRl"!Y SEPTEMBER - 2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAY-2016
030TEXAS DIVISION SYSTEM INTEGRl"!Y MAY-2016
o:m TEXAS DIVIS!ON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TE)(AS DIVlSION SYSTEM INTEGRl"!Y OCTOBER - 2016
oao TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTIOGRITY MAY-2016 '
030 TEXAS DIVISION SYSTEM !NTEGRl1Y AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS OIVlSION SYSTEM INTEGRITY MAY-2016
O:lO TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION S\"STEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl"!Y MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVlSION SYSTEM lNlEGRl1Y AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2018
000 TEXAS DIVISION SYSTEM INTEGRl"!Y MAY-:2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D1VISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEM6ER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRl"!Y MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRl"!Y MAY-2016
UNE No. PROJECT NUMBE~ COST(1)
3219 030.37613 2.230
3220 030.3'7615 25
3221 030,37623 33
3222 030.37624 25
3223 OJ0.37633 155
3224 030.37638 207
3225 030.37650 29
3226 030.37651 7,85B
3227 030.37656 31,982
3228 030.37657 284
3229 030.37664 466
J230 030_37673 2,292.
J2:J1 030.37678 68
3232 030.37709 496
3233 030.37711 9
3234 030.37739 :a,695
3235 030.37750 2,534
3236 0'30.37751 5.517
3237 030.37752 2,513
3238 030.37758 8,652
3239 030.37781 27.658
3240 030.37768 10
3241 030.37773 36
3242 030.37799 47
3243 o:m.a1a24 567
3244 030.37830 692
3245 030.37833 2,369
3246 030.37641 30,364
3247 030.37848 3
3248 030.37-857 6.014
3249 030.37870 151
3250 030.37883 53
3251 030.37916 685
3252 030.37918 15,276
ALLOCATED COST
2.,230
25
33
25
155
207
29
7.856
31.982
284
466
2.292
5a
496
ATMOS ENERGY CORPORATION, WES.TTEXAS mVISION INTERIM COST RECOVERY ANO RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 [21 BENEFITED
INSTALL 800 FEET OF 2 lNCH POLY MAIN WITH 12 SERVICES AND RETIRE 800 FEET OF 2 INCH S1EEL MAJN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX
RETIRE 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WnH RAILROAD COMMISSION OF TEXAS RULE 0.209 ALL· MIX
RETIRE 1 SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 All-MIX RETIRE 1 STEEL SERVICE DUE TD SYSTEM INTEGRITY IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 /\LL-MIX RETIRE 415 FEET DF 3 INCH STEEL MAIN AND 24 FEET OF 2 INCH STEEL M,ajN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 STEEL SERVICE OUE TD SYSTEM INTEGRITY IN ACCORDANCE WITH RAlLROAD COMMISSION Of TEXAS RULE 8,209 ALL-MIX INSTALL2153 FEET OF 4 INCH POLY MAIN AND RETIRE2774 FEET OF 2 INCH AND 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RUlE 8.209 ALL-MIX INSTALL 10795 FEET DF2 INCH POLY MAIN AND 98 SERVICES AND RETIRE 12406 FEETOF1, 1.25, 2, 3, AND 4 INCH STEEL MAIN ANO 96 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REBUILD METER SETIING IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 ALL-MiX
INSTALL 1261 FEET OF 2 INCH POLY MAIN WITH 16 SERVICES AND RETIRE 1261 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WIT>l RAlLRAOO COMMISSION Of TEXAS RULE 8.209 ALL-MIX lNSTALL 34B FEET OF 2 INCH POLY MAIN AND REGULATOR STATION AND RETIRE 225 FEET OF 3 INCH STEEL MAIN, 123 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WJTI-l RAILROAD COMMISSION OF lEXAS RULE 8.209 ALL-MIX RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
INSTiil.LEO 17 FEET Of 2 INCH POLY MAIN AND RETIRE 741 FEET OF 2 INCH STEEi.. 108 FEET OF 4 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 STEEL SERVICE DUE TD SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
9 8.209 ALL· MIX INSTALL 664 FEET OF 2 INCH POLY MAIN. 81 FEET OF 1.25 INCH POLY MAIN WffH 16 SERVICES AND RETIRE 745 FEET OF 2.5 INCH STEEL IN ACCDROANCE WITH RAILROAD COMMISSION OF TEXAS
3.695 RULE 8.209 INSTALL 383 FEET OF 2 INCH POLY WITH 6 SERVICES AND RETIRE 428 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH
2.534 RAILROAD COMMISSION Of TEXAS RULE 8.209 REPLACE AND REE.DCATE FACILITIES: RETIRE 2288 FEET OF 2 INCH STEEL MAIN AND INSTALL 386 FEET OF 2 INCH POLY MAIN ANO 2 ASSOCIATED S!ORVICES DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE; WITH RAILROAD COMMISSION OF TEXAS RULE
5,517 8.209
INSTALL 3SB FEET OF 2 !NCH POLY MAIN WITH 10 SERVICES AND RETIRE 366 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH
2,513 RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 850 FEET OF 8 INCH STEEL MAJN AND RETIRE 850 FEET OF 8 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
6,652 COMMISS[ON OF TEXAS RULE B.209 INSTALL 11.091 FEET OF 2 INCH POLY MAIN WITH 160 SERVICES AND RETIRE 13,482 FEET OF 4 INCH ANO 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RlJLE
27,858 6.209 RETIRE 1 STEEL SERVICE DUE TD SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
10 8,;209
RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
36 8.209 RETIRE 275 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH
47 RAILROAD COMMISSION OF TEXAS RULE 6.209 REBUIU> LARGE VOLUME METER SETTING DUE TD SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION
567 OF TEXAS RULE 8.209 REPLACE OBSOLETE METER SEITING IN ACCORDANCE WITH
692 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL567 FEET OF 1.25 INCH POLY MAIN ANO RETIRE 665 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
2,369 COMMISSION OF TEXAS RULE 6.209 INSTALL 5429 FEET OF 6 !NCH STEEL MAIN AND 4 SERVICES AND RETIRE 5429 FEET OF 6 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
30.364 8.209 RETIRE 1250 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH
3 RAILROAD COMMISSION Of TEXAS RULE 8,209
6.014
151
53
685
15.276
lNSTALL 1000 FEET OF 2 INCH POLY MAIN WlTH 19 SERVICES ANO RETIRE 1000 FEET OF 2 INCH PVC IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 433 FEET OF 2 INCH POLY MAIN WITH 4 SERVICES AND RETIRE 433 FEET OF 2 INCH STEEL MAIN IN AoCDRDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 8.209 INSTALL341 FEET OF 21NCH POLY MAIN AND 1 SERVICE AND RETIRE 326 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL6550 FEET OF 2 INCH POLY MAIN WITH 158 SERVICES AND RETIRE 6650 FEET OF STEEL MAlN AND 4 REGULATOR STATIONS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX Addillons Page 86 of98
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
All.- MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
DATE PLACED !N GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SE!'TEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
! 030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS SEPTEMSER - 2c1e
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DlVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS D!VIS!ON SYSTEM INTEGR!TY MAY-2018
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER • 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OClOB!:::R • 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISlON SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST- 2016
030 TEXAS OIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INT!OGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
LINE NO. PROJECT NUMBER COST(1l
3253 030.37930 2,095
3254 030.37932 46
3255 030.37933 13
3256 030.37934 20
3257 030.37943 39
3258 030.37950 2,496
3259 030.37969 1,137
3260 030_37970 6,905
3261 030.37971 I 54
3262 030.37985 46
3263 oao.37986 16
3264 030.38003 3,149
3265 030.38016 2,178
3206 030.38019 30
3267 01m.3so20 118
3268 030.38021 81
3269 030.36023 2,117
3270 030.38042 2.442
3271 030.36049 404
3272 030.38061 76
3273 0'30,38062 BB
3274 030.38063 75
I 3275 030.38080 1.934
3276 030,38097 4B5
3277 030.38108 1.886
3278 030.38110 7.085
3279 030.38125 4.674
3280 030,38137 114
3281 030,38148 9.044
3282 030.38151 3,314
3283 030.38152 966
3284 030.38154 2,980
3285 030.38177 5,688
3286 030.38181 1,944
ALLOCATED COST
2,095
46
13
20
39
2,496
1.137
6,905
54
46
16
3,149
2,178
30
118
., 2,117
2,442
454
76
8B
75
1,934
485
1,8"'3
7,085
ATMOS ENERGY CORPORATION, WESTTEXAS DIVISION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUllLIC USE IN CALENDAR YEAR 2016 (2) BENEFITED
INSTAll 2132 FEET OF 2 INCH POLY MAIN WrTH 3 SERVICES AND RETIRE 2132 FEET OF 2 INCH PVC, 710 FEOT OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 STEEL SERVICE DUE TD SYSTEM INTEGRITY IN AcCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX
INSTALL 160 FEET OF 2 INCH POLY MAIN WITfl708ERVICES AND RETIRE 160 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 ALL-MIX RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL360 FEET OF 1.25 POLY MAIN AND RETIRED 21NCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE B.209 ALL-MIX REPLACE 50 FEET OF 16 INCH STEEL MAIN WllH 16 INCH STEEL MAIN DUE TO IN ACCCORDANCE WITH RAILROAD COMMISStON OF TEXAS RULE 6.209 ALL-MIX REPLACE AND LOWER 250 FEET OF 2 INCH POLY MAIN WITK 2 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTAl.L 115 FEET OF 3 INCH STEEi. MAIN. 238 FEET OF 6 INCH STEEi. MAIN WITH 4 SERVICES AND RETIRE 1 FOOT OF 6 INCH STEEi. MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 8,20!! ALL-MIX RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD OOMMISSIOl>I Of TEXAS RULE a.209 ALL-MIX RETIRE 1 STEEi. SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX INSTALL 3275 FEET OF 4 INCH POLY MAIN AND RETIRE 3322 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE Will-I RAILROAD COMMISSION OF TEXAS RULE 8.2<l9 ALL-MIX
INST ALL 846 FEET OF 2 INCH POLY MAIN WITH 8 SERVICES AND RETIRE 846 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX RETIRE 1 STEELSERV1CE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 STEEL SERV1CE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 12274 FEET OF 2 INCH STEEL IN ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX INSTALL 3B5FEET OF2 INCK POLY MAIN AND RRIRE 1926 FEET OF B INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.200 ALL-MIX
INSTALL 850 FEET OF 2 INCH POLY MAIN WITH 7 SERVICES AND RETIRE 850 FEET OF 1 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
INSTALL 90 FEET OF 2 INCH POLY MAIN AND RETIRE 1o0FEET OF 2 INCH STEEL AND 303 FEET OF a INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E B.209 ALL-MIX RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 100 FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 921 FEET OF 4 INCH POLY MAIN AND 1 SERVICE AND RETIRE 900FEETOF2 INCH STEEL MAiNAND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALl.-MIX REBUILD METER SETTING IN ACCORDANCE WITI-1 RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
REPLACED 160 FEET OF 8 INCH STEEl. MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 1 OQO FEET OF 2 INCH POLY MAIN WITH 17 SERVICES ANO RRIRE 1000 FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 474 FEET OF 6 INCH POLY MAIN AND RETIRE474 FEET
ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE IOF 8 INCH STEEL MAIN AND27 FEET OF6 INCH STEEL MAIN IN
4,674 8.209 All-MIX
114
9,044
3,314
966
2,:9!:!i0
5,688
1,944
RETIRE 2 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
INSTALL 5656FEET OF2 INCH POLY MAIN AND RETIRE 1008 FEET OF2 INCH ABS. 717 FEET Of 2 INCH POLY MAIN. 3570FEET OF2 INCH PVC IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INST ALL 2471 FEET OF 2 INCH POLY MAIN AND 13 SERVICES AND RETIRE 1607 FEET OF 2 INCH POI. Y MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 546 FEET OF 2 INCH POLY AND 18 SERVICES AND RETIRED 546 FEET OF 2 INCH STEEL lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INST ALL 1516 FEET OF 2 INCH POLY MAIN AND 10 SERVICES AND A.E.lll=i:~ 1516 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH J=:IAILl1:0Ab COMMISSlDN OF TEXAS RULE B.209
INST ALL 6167 FEET OF 4 INCH POLY MAIN AND RETIRED 499 FEET OF 3 INCH STEEL. 5320 FEET OF 2 INCH STEEL, 3961 FEET OF 2 INCH PVC, BS FEET OF 2 INCH POl Y IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION !JUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 8.209
WlXAddltion!I; Pase 87 of~B
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM li'lTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM lNTEGRllY MAV-2018
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2015
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DMSlON SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION PUBLIC IMPROVEM!ONTS SEPTEMBER - 2016
030 TEXAS DIVISION PUBLIC tMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
OJO TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITI' MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY Sl::~TEMBER • 2.016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY.2016
030 TEXAS DMSION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2010
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY JUNE-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY·2<l1B
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM !NTEGRffV SEPTEMBER - 2016
030TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRtlY SEPTEMBER-2016
030 TEXAS DMSION SYSTEM INTEGRITY SEPTEMBER· 2016
OJO TEXAS DIVISION PUBLIC IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER ~ 20118
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST -2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEM!!ER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DMSION SYSTEM IMPROVEMENTS SEPTEMBER~ 2015
LINE No. PROJECT NUMBER COST(1)
3287 030.38185 275,073
J2B8 030.38187 32,330
3289 030.38195 2.549,043
3290 030,381:99 947
3291 030.38200 170
3292 030.38202 3.491
3293 030.38204 46,890
3294 030,38208 1,597
3295 030.38214 104
3296 030.36215 2
3297 030.38216 70
3298 030.38217 8
3299 030.38218 SU
3300 030.38241 952
3301 030.38250 59
3302 030.38259 329
3303 030.36266 M41
3304 030.38276 132
3305 030.36263 1,912
3306 030.362a6 451
3307 030.38292 16
:a3oa 030.38325 1,310
3309 030.36346 142
3310 030,38353 53
3311 030.38372 8
3312 030.38384 274
3313 060.38389 626
3314 030.38390 27
3315 030.36~06 B16
3316 030.38407 2,039
3317 030.38412 714.205
3318 030.38414 632
3319 030.38432 67
3320 030.38433 25
3321 030.38434 25
3322 030.384'"3 320
ALLOCATED COST
275.073
32,330
2,649.043
947
170
3.491
46.890
1,597
104
2
70
ATMOS EN£RGVCORPORAnDN, WEST TEXAS OMSION
INTERIM COST RCCOVEMY AND RATE A.DJUSTMENT REPORT
PR03£CT R£PORfC'f 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 (2] BENEFITED
INSTALl419 FEET DF6 INCH STEEL MAIN AND RETIRE419 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAO COMMISSION OF TEXAS RULE 8.209 All-MIX INSTALL 136 FEET OF 8 INCH STEEL MAIN AND 21153 FEET OF 2 !NCH POLY MAIN AND 130 SERVICES AND RET!RE 17061 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 8.209 All.- MIX
INSTALL 12,675 FEET OF 16 INCH STEEL MAIN AND 60 FEET OF 6 INCH STEEL MAIN AND 1 REGULATOR STATION AND RETIRE 12,000 FEET OF 16 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX INSTALL <?8 FEET OF 8 INCH STEEL MAIN. 28 FEET OF 8 INCH POLY MAIN AND RETIRE 28 FEET OF 8 INCH STEEL MA!N IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL· MIX INSTALL 328 FEET OF 2 INCH POLY MAIN AND RETIRE 271 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTAU. 225 FEET OF 8 INCH STEEL MAIN AND RETIRE 225 FEET OF B INCH STEEL MAIN IN ACCORDANCE WITH RAILRAOD COMMISStON OF TEXAS RULE B.209 ALL-MIX REBUILD REGULA TOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 1115 FEET OF 4 INCH POLY MAIN AND RETIRE 1270 FEET OF 4 INC!l STEEL MAIN IN ACCORDANCE Willi RAILRADD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 180 FEET OF 6 INCH 1..P STEEL PIPE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MlX RETIRE 134 FEET OF 2 INCH STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX RETIRE 1 STEEL SERVICE DUE TD SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
B 8.209 ALL-Ml)( RETIRE 246 FEET OF 2 INCH POLY MAIN AND 24673 FEET OF 2 INCH PlASTIC MAlN IN ACCORDANCE Willi RAILROAD
66 COMMISS~ON OF TEXAS RULE 8.209 INSTALL 344 FEET OF 2 INCH POLY MAIN WITH 7 SERVICES IN ACCORDANCE WITH RAILRADD COMMISSION OF TEXAS RULE
952 8.209 INSTALL 1 SERVICE AND RETIRE 1 SERVICE IN ACCORDANCE
59 WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 6 FEET OF 4 INCH STEEL MAIN AND RETIRE 200 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE Willi RAILROAD
329 COMMISSION OF TEXAS RULE 8.209 INSTALL 175 FEET OF 2 INCH POLY MAIN, 487 FEET OF4 INCH POLY MAIN, 620 FEET OF 2 INCH STEEL MAIN AND RETIRE 1'50 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE Willi RAILROAD
3,641 COMMISSION OF TEXAS RULE 8.209 RETIRE 275 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH
132 RAILROAD COMMISSION OF TEXAS RULE 8.209
lNSTAll 739 FEET OF 4 INCH POLY MAIN AND 16 SERVICES AND RETIRE 739 FEET OF 4 iNCH STEEL MAIN ~N ACCORDANCE WITH
1,912 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 90 FEET OF 4 INCH STEEL MAIN AND RETIRE 90 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
451 COMMISSION OF TEXAS RULE 6.209 RETIRE 1 STEEL SERVICE DUE TO SVSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
16 8.209 REPLACE 45 FEET OF 8 INCH STEEL MAIN WITH 45 FEET OF 8 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
1.310 COMMISSION OF TEXAS RULE 8.209 INSTALL 1319 FEET OF 2 INCH POLY MAIN AND RETIRE 1325 FEET OF 2 INCH PLASTIC MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
142 8.209 REPLACE OBSDl.ETE REGULATORS AND REBUILD METER SETTING IN ACCORDANCE WITH RAILROAD COMMISSION OF
53 TIEXAS RULE 6.209 RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUU;
8 B.209
274
626
27
618
2,039
714,205
632
67
25
25
320
INSTALL 1 SERVICE AND RETIRE 1 SERVJCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 26 FEET OF 4 INCH STEEL MAIN AND RETIER 18 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1742 FEET OF 2 INCH PVC MAIN IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE 8.209
INSTAU. 654 FEET OF 4 INCH POLY MAIN WITH 4 SERVICES AND RETIRE 327 FE!OT OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 340 FEET OF 2 lNCH POLY MAIN WITH 3 SERVICES AND RETIRE 340 FEETO OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 6,400 FEETOF2 INCH POLY MAIN AND 33 SERVICES AND RETIRE 6,400 FEET OF 3 INCH STEEL MAlN AND 33 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 20 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAIL.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL ONE .75INCH OF POLY SERVICE AND RETIRE 1.25 INCH OF STE~L SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 6.209 RETIRE 1 SEf:iVICE IN ACCORDANCE WITH .RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 7 FEET OF2 INCH STEEL MAlN AND RETIRE 7 FEETOF2 INCH STEEL MAIN IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 6.209
WIX Addrtram; Page88of98
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
All.-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All.-MIX
All· MIX
All· MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GASPLANTIN
1.0CATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DlVISION SYSTEM IMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2015
031l TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER· 2016
031J TEXAS DIVISION SYSTEM INTEGRITY MAY·2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2015
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST -2016
030 TEXAS DIVISION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS OMS ION SYSTEM INTEGRITY MAY-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER~ 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAB DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBE;R - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXAS DIVIS~ON SYSTEM INTEGRITY SEPTEMBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST~ 2016
030 TEXAS DIVlSlON SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
LINE ALLOCA,TED NO. PROJECT NUMBER COST(1) C.OSl
3323 030.38443 2,310 2,310
3324 030.38451 (1301 (130)
3325 030.38464 18 18
3326 030.3El495 3,775 3,775
3327 030_38496 33,BS7 33,867
:aa.2a 030,38499 33,674 3'3,674
3329 030.38506 2,402 2,402
3330 OJ0.38511 31,711 31,711
3331 030.38514 8,400 8,400
3332 030.38517 20 20
3333 0'30,385213 843 843
3334 030.30028 490 490
3335 000.38529 4 4
3338 030.38537 11,551 [1,5511
3337 030.38560 165,902 165,902
3338 030.38567 10,781 10,761
33'39 030.38574 183.816 183,815
3340 030.38575 379,201 379,201
3341 030.38581 208,029 208,029
3342 030.38588 129,459 129,459
3343 030.38615 248.434 2.48,434
3344 030,38776 11,274 11,274
3345 030.38794 1210 12101
3346 030.38796 13,125 13,125
3347 030.38800 1S9,14tl 189,146
3346 030.38807 1 1
ATM05 ENERGY CORPOMTION, WEST TEXAS DIVISION INTERIM COST RECOVERY AND RATE AOJUS.TMENT REPORT
PROJECT REPORT CY2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 135 FEET OF 8 INCH STEEL MAIN AND RETIRE 80FEET OF 4 INCH AND 20 FEET OF 8 INCH STEEL MAIN IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE 8.209 INSTAll3408 FEET OF 2 INCH POLY ANDRETIRE27B FEET OF 4 INCH STEEL IN ACCORDANCE: WITH RAILROAD COMMISSION OF TEXAS RULE a.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
LUBBOCK OPERATIONS BLANKET TO COVER REPLACl'/RETIRE TASKS: SERVICE LINES, PIPES FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, RE;GULATORS AND METER LOOPS IN ACCCORPANCE WITH RAILROAD COMMISSION OF T<XAS RULE 8.209
lUBBOCK OPERATIONS !ILANKETTO COVER REPLACE/RETIRE TASKS; SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH PIAMETER. ANODES. METERS. REGULATORS AND METER lOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULc 8.2'l9
PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMtSSION Of TEXAS RULE 8.209
SEMINOLE/BROWNFIELD OPERATIONS BLANKET TO COVER REPLACEtRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WJTH RAILROAD COMMISSION OF TEXAS RULE 8_209 RETIRE 1 STEEL SERVICE DUE TO SYSTEM INTEGRl1Y IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S.209
INSTALL 309 FEET OF 2 INCH POLY MAIN WITH 5 SERVICES AND RETIRE 289 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 311 FEET OF 2 INCH POLY MAIN WITH 5 SERVICES AND RETIRE 311 FEET OF 2 INCH STEEL MAIN ""ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 19B3 FEET OF 3 lNCH POLY MAIN IN ACCO.RDANCE WITH RAILROAD COMMISSION OF TEXAS .RULE 8.209 INSTALL 100 FEET OF2 INCH AND 8496 FEET OF 4 INCH POLY MAIN AND 23 SERVICES AND RETIRE 30 FEET OF 2 INCH AND 7556 FEET OF 3 INCH PLASTIC AND 275 FEET OF 3 INCH STEEL MAIN AND 23 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6420 FEET DF 3 INCH POLY MAIN AND RETIRE 8420 FEET OF 3 INCH STEEL MAIN AND REPLACE 78 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2814 FEET DF 6 INCH POLY MAIN AND B SERVICES IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6679 FEET OF 2 AND 4 INCH POLY MAIN AND RETIRE 6879 FEET OF VARIOUS SIZE STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXl\S RULE B.209
INST ALL 7273 FEET OF 2 INCH POLY MAlN A~D 74 SERVICES AND RETIRE3123 FEET OF 4 INCH STEEL MAIN AND4022 FEET OF 3 INCH STEEL MAIN AND 74 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 11155 FEET OF 2 INCH POLY MAIN AND 219 SERVICES AND RETIRE 9483 FEET OF 2 INCH AND 2264 FEET OF 3 INCH STEEL MAIN AND 219 SERVICES IN ACCORDANCE WITH RAILROAO COMMISSION OF TEXAS RULE 8.209 INSTALL 10020 FEET OF 2 INCH POLY MAIN AND 56 SERVICES AND RETJRE 10020 FEET OF 2 INCH PLASTIC MAIN AND 56 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5955 FEET OF 2 INCH AND 3665 FEET DF 4 INCH PDL Y MAJN AND 145 SERVICES AND RETIRE 5094 FEET OF 2 INCH AND 3464 FEET OF 3 INCH STEEL MAIN AND 145 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SVSTEM IMPROVEMENT IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 765 FEET OF 4 INCH POLY MAJN AND RETIRE 785FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 s INST ALL 1800 FEET OF 6 INCH POLY MAIN AND 5 SERVICES AND RETIRE 1800 FEET OF 10 lNCfl STEEL MAJN AND5 SERVICES IN ACCORDANCE WJTH RAlLROAP CDMMISSION OF TEXAS RULE 8.209 INSTALL6505 FEET OF2 INCH AND 3895 FEET OF 4 INCfl POLY MAtN AND 3 SERVICES AND RETIRE 5750 FEET OF 2 INCH AND 3265 FEET OF 3 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WiTH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 300 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 300 FEET DF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAlU;:oAO COMMISSION OF TEXAS RUlE 8.209
WTX Additions fl';;ige eg af98
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
OATE PLACED IN GAS PL.ANTIN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DMSION SYSTEM INTEGRITY SEP'f~MBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DMSJON SYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DIVISION SVSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVlSION SYSTEM INTEGRITY DECEMBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2018
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER • 2016
030 TEXAS DIVISION SYSTEM fNTEGRlTY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DMSION SYSTEM INTEGRl1Y OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRllY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXl\S DIVISION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXAS DIVISION SYSTEM lMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y SEPTEMBER "2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
LINE NO. PROJECT NUMBER COST[11
3349 000.36611 77,011
3350 030.36671 2
3351 030,38677 10
3352 030.38885 2
3353 030.38924 1,576
3354 030,38927 14,352
3355 030.36959 (797)
3356 030.39010 2,636
3357 030.39044 930
3368 030.39045 21,757
3359 030.39075 715,481
3360 030.39112 2
3361 030.39121 281,580
3362 030.39132 11,3511
3363 030.39137 541
3364 030.39142 496
3365 030.39143 7,384
3366 030.39153 299,825
3387 030.39177 21!i.S65
3366 030.39163 41,114
3369 030.39168 32,222
3370 030.39194 67
3:371 030,3:9284 (2.453)
3372 030.39285 472,508
3373 030.39285 488,630
3374 030.39294 6,414
3375 030.39302 423,270
3376 030.39304 751,011
3377 030.39337 475,267
3378 030.39862 46,063
ALLOcATED COST
77.011
ATMOS EN:ERGV CORPORATION, WES.T TEXAS DIVISION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT R.EPO:flT Cf 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR2016 [21 BENEFITED
INSTALL 100 FEET OF 1.25 INCH. 7000 FEET OF 2 INCH, ANOS69 FEET OF 4 INCH POLY MAIN AND 56 SERVICES AND RETIRE 6043 FEET OF VARIOUS SIZE STEEL MAIN AND 56 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUUE 8.209 ALL~ MlX
INST ALL 10 FEET OF 2 INCH AND 147 FEET OF 4 INCH POLY MAIN AND RETIRE 166 FEET OF 2 INCH POLY MAIN IN ACCORDANCE
2 WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX RETIRE 243 FEET OF 3 INCH AND 45 FEET OF 2 INCH STEEL MAIN AND 75 FEET OF 2 INCH POLY MAIN IN ACCORDANCE WITH
10 RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
2 COMMISS!ON OF TEXAS RULE 8.209 INSTALL 431 FEET OF 2 INCH POLY MAIN AND RETIRE 431 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITl-I RAILROAD
1.li76 COMMISSION OF TEXAS RULE 8.209 INSTALL 320 FEET OF 1.25 INCH POLY SERVICE AND RETIRE 247 FEET OF 1 INCH STEEL SERVICE IN ACCORDANCE WITH
14,352 RAILROAD COMMISSION OF TEXAS RULE 8.209 S INST ALL 22 FEET OF 4 INCH STEEL MAIN AND RETIRE 64 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
1797 COMMISSION OF TEXAS RULE 8.209 REBUILD CPR SETTING IN ACCORDANCE WITH RAILROAD
2,838 COMMISSION OF TEXAS RULE 6.209
REPLACE 157 FT OF 2 INCi-i PVC WITH 2 IN POLY IN ACCORDANCE 930 WITH RAILROAD COMMISSION OF TEXAS RULE B.209
RELOCATE fi:50 FEET OF 3 INCH STEEL MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION
21,757 OF TEXAS RULE 6.209
INSTALL22,500 FEET OF 6 INCH POLYMA!N AND430B FEET OF 2 INCH POLY MAIN AND 1 REGULATOR STATION AND RETIRE 30,000 FEET OF 12 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE
715,481 WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE 379 FEET OF 2 INCH POLY MAIN DUE TO IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
2 6.209
281,580
11,3511
541
498
7,384
299,825
215,665
41,114
32,222
61
[2,4531
472,508
488,630
6.414
423,270
751.011
475,267
46,063
INST Al.L 8 FEET OF VARIOUS SIZE PIPE AND RETIRE TWO VALVE NEST DUE TO SYSTEM INTEGRITI IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1412 FEET OF 2 INCH POLY MAIN AND RETIRE 1412 FEET OF 2 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 5 FEET OF 2 INCH STEEL MAIN AND RETIRE 5 FEET OF 3 INCH STEEL MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 400 FEET OF 4 INCH POLY MAIN AND RETIRE 400 FEET OF 4 INCHPOLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 S INSTALL 330FEET OF2 INCH POLY MAINA.~D RETIRE 330 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUUE 6.209 INSTALL 3298 FEET OF 2 INCH POLY MAIN 7487 FEET OF 2 INCH POLY MAIN AND 35 SERVICES ANO RETIRE 10,851 FEETOF2 INCH PVC MAIN AND 35 SERVICES !N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS .RULE B.209 INSTALL 7082 FEET OF 2 INCH POLY MAIN AND 70 SERVICES AND RETIRE 7062 FEET OF 3 INCH STEEL MAIN AND 70 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSiON OF TEXAS RULE 8.209 INSTAL(. 360 FEET OF 2 INCH STEEL MAIN AND 7 SERVICES AND RETIRE 380 FEET OF 3 INCH STEEi. MAIN AND 7 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 432 FEET OF 4 lNCH POLY MAIN AND 4 SERVICES AND RETIRE 460 FEET OF 4 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RLJLE 6.209 RETIRE 2500 FEET OF 2 INCH PLASTIC MAIN DUE TO IN ACCCORDANCE wm1 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 750 FEET OF2 INCH POLY MAIN AND RETIRE750 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 615 FEET OF 4 INCH POLY MAIN AND 5886 FEET OF2 INCH POLY MAIN AND 106 SERVICES AND RETIRE 7708 FEET OF VARIOUS SIZES STEEL MAIN AND 111 SERVICES IN ACCORDA~CE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 3585FEET OF 4 INCH POLY MAIN AND 6510FEETOF 2 INCH POLY MAIN AND 138 SERVICES AND RETIRE 4184 FEET OF PVC MAIN AND 136 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSiON OF TEXAS RULE 8.209 INSTALL360 FEET OF 21NCH POLY MAIN ANO RETIRE 360Fl'ET OF 2 INCH OF STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RULE 6.209 INSTALL 6036 FEET OF2 INCH POLY MAINAND 8244 FEET OF 4 INCH POLY AND 63 SERVICES AND RETIRE 11,597 FEET OF PVC MAIN AND 63 SERVICES IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RUUE 6.209
REPLACE 10,980 FEET OF 2 INCH AND 425 FEET OF 4 INCH STEEL WITfl 10,940 FEET 2 INCH AND 525 FEET 4 INCH POLY AND 224 SERVICES DUE TO SYSTEM INTEGRITI IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 6820 FEET OF 1 INCH 2 INCH AND 3 INCH STEEL WITH 4840 FEET OF2 INCH AND 2974 FEET OF4 POLY AND INSTAl.L46 SERVICES IN ACCORDANCE WrTH RAILROAD COMMISSION OF TEXAS RULE 6.209
REPLACE 147 FEET OF 3 INCH STEEL MAIN WITH 147 FEET OF 2 INCH POLY PIPE ANO REPLACE 3 1 INCH STEEL SERVICES WITl-I .751N POLY PlPE DUE TO SYSTEM INTEGRITY JN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTXAddltlons Pase 90 of93
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
Al.L-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
Al.L-MIX
All-MIX
ALL-MIX
ALL-MlX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBER - 2016
030 TEXAS DiVIS!ON SYSTEM INTEGRITI SEPTEMBER - 2016
03-0 TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBER • 2016
03-0 TEXAS DIVISION SYSTEM INTEGRITI AUGUST - 2016
030 TEXAS DIVISION SYSTEM lNTEGRllY SEPTEMBER ~ 2016
030 TEXAS DIVISION SYSTEM INTEGRITI AUGUST -2016
030 TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST· 2016
030 TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBER~ 2016
030 TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITI OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBl'R - 2016
030 TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBER -2016
030 TEXAS DIV!SION SYSTEM INTEGRITY SEPlEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITI SEPTEM!lER - 2016
030TEXAS DIVISION SYSTEM INTEGRITI SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITI DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITI DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITI AUGUST - 2016
LINE ALLOCATED No. PROJECT NUMBER COST{1) COST
3379 030.39372 506.577 500,577
3380 030.39374 689 689
3381 030.393/9 3,165 3,165
3362 030.39385 16,806 16,806
3383 030.39390 2,220 2,220
3384 030.39397 512 512
3385 030.39415 28,520 28.520
3386 030.39427 2,397 2,397
3387 030.39430 46,261 46,261
3388 030.39431 61,759 51,759
3300 030.39432 52,592 52,892
3300 030.39434 54,831 54,831
3391 030.39447 45,700 45,700
3392 030.39446 39,713 39,713
:3393 030.39449 45,802 45,802
3394 030.39456 9,751 9,751
3395 030.39471 41,080 41,060
3396 030.39475 378,092 378,092
3397 030.39513 47,438 47,438
3398 030.39517 2,740 2,740
3399 030.39531 112,764 112,764
3400 030.39533 4.126 4,126
3401 030.39534 325,912 325,912
3402 030.39540 51,766 51,766
3403 030.39642 92,235 92,235
3404 030.39544 3,122 3,122
3405 030.39547 45,365 45,365
3406 030.39548 45,315 45,315
3407 030.39549 49,752. 49,752
3406 030.39550 44,465 44.465
3409 030.39562 42.774 42,774
3410 030.39553 42,160 42,1BO
3411 030.395:54 48,366- 46,365
ATMOS ENERGY CORPORAYlON, WEST TEXAS. PIVlSION lNTfRIM COST ft.ECOVERY AND RATE A.OJU.STMENT REPORY
PROJECT ll~PORTCT 2016
DESCRIPTION OF COMPLETED PROJECTS OEOICATJ:D TO PUBLIC USE IN CALENDAR YEAR 2015 ~2)
REPLACE 3225 FEET2 INCHANO 2500fEETOF3 INCH STEEL MAIN WITH POLY PIPE AND REPLACE 511 IN AND 3 2 IN STEEL SERV1CES WITH POLY PIPE WHILE REPLACING METERS AND LOOPS DUE TO SYSTEM INTEGRJTY lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE S.209 INSTALL 60 FEET OF 2 INCH POLY MAIN ANDRETIRE60 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAIL.ROAD COMMJSSION OF TEXAS RULE B.209 INSTALL 147 FEET OF 2 INCH POLY MAIN AND RETIRE 147 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RA•lROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 1040 FEET OF 2 POLY STEEL M/\IN AND 5 SERVICES AND RETIRE 1040 FEET OF 2 INCH STEEL MAIN AND 6 SERVICES IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 48 FEET OF 4 INCH STEEL MAJN ANO RETIRE 38 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ABANDON 1038 FEET OF 2 INCH STEEL MAIN AND 9 SERVICES AND REPLACE 1 SERVICE IN ACCORDANCE w1m RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 78aFEET OF 4 INCH POLY MAIN AND 11 SERVICES AND RETIRE 788 FEET OF 3 INCH STEEL MAIN AND 11 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE DEEPWELL IN AMARILLO TD IMPROVE CATHODIC PROTECTION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPl.ACE DEEPWELL IN SANFORD TO IMPROVE CATHODIC PROTECTION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN PANHANDLE TO IMPROVE CATHDDlC PROTECTION IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN WASHBURN TO IMPROVE CATHODIC PROTECTION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN CONWAY TO IMPROVE CATHODIC PROTECTION IN ACCORDANCE wmi RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN PLAINVIEW TO IMPROVE CATHODIC PRDTECTlDN DUE TD SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN SILVERTON TD IMPROVE CATHODIC PROTECTION DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 5.209 REPLACE DEEPWELL IN FLOYDADA TD IMPROVE CATHODIC PROTECTION DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 101 FEET OF 4 INCH POLY MAJN ANO 1 SERVICES AND RETIRE 150FEETOF 4 INCH STEEL MAIN ANO 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OFTEXAS RULE 8.209 REPLACE DEEPWELL lN MIDLAND TO IMPROVE CATHODIC PROTECTION DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 3610 FE~2 JNCHPOLY MA!N.AND 76 31411 POLY SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REROUTE 1045 FEET OF 2 INCH POLY DUE TD SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 104 FEET OF 4 INCH POLY MAIN AND RETIRE 120 FEET OF 4 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTAU. 42 FEET OF 3 INCH STEEL MAIN AND 58S FEET OF 6 INCH STEEL MAIN AND 136FEET OF 2 INCH POLY MAIN /\ND 2 SERVICE:S AND RETIRE 765 FEET OF 6 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 750 FEET OF 2 INCH STEEL WITH 2 INCH POLY PIPE IN ACCCDRDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5793 FEET OF 2 INCK POLY MAIN AND 53 SERVICES AND RETIRE 5793 FEET Of 2 INCH STEEL MAIN AND 53 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE DEEPWELL IN AMARILLO TO IMPROVE CATHODIC PROTECTION DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200 REPLACE DEEPWELL IN DALHART TD IMPROVE CAT110DIC PROTECTION DUE TO SYSTEM INTEGRITY ~N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REFlACED 2 INCH DRESSER COUPLING WITH 5 FEET OF 2 INCH STEEL DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 REPl.AOE DEEPWELL IN DALHART TO IMPROVE CATHODIC PROTECTION DUE TD SYSTEM INTEGRITY IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN ODESSA TD IMPROVE CATHODIC PROTECTION DUE TO SYSTEM INTEGRITY IN ACCORDANCE Wl1H RAILROAD COMMISSION OF TEXAS RULE 5,209
REPLACE DEEPWELL IN BROWNFIELD TD IMPROVE CATflDDIC PROTECTION DUE TD SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSiON OF TEXAS RULE 8.209 REPLACE DEEPWELl IN ODESSA TO IMPROVE CATHODIC PROTECTION DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH R/\ILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN LITILEFIELD TO IMPROVE CATHODIC PROTECTION DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 REPLACE OEEPWELL IN LITTLEFIELD TO IMPROVE CATHODIC PROTECTION OUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REPLACE DEEPWELL IN LUBBOCK TO IMPROVE CATHODIC PROTECTION DUE TD SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
WTXAddU!ons Page 91 of98
CUSTOMERS BENEFITED
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL- MIX
AL!.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MlX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALl-MlX
ALL-MIX
ALL- MIX
ALL-MIX
All-MIX
AllaM!X
0AJE.PLACEO IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY sEPTEMBER - 2016
030 TEXAS DIVISION SYSlEM tNTEGRHY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER M 2016
030 TEXAS DIVISION sYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS OIVIStON SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 201fl
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER ~ 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
OJOTEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUS'J'-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST -2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION PUBUC IMPROVEMENTS SEFTEMBER - 2016
030 TEXAS DIV1SION SYSTEM INTEGRITY AUGUST" 2016
030 TEXAS DIVlSlON SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGR~TY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2010
LINE ALLOCATED NO, PROJECT NUMBER COST(1J COST
3412 030.39557 4$;936 43,936
3413 030.39666 42,991 42,991
3414 030.39559 53,2"4 53,204
3416 030.39560 58,062 58,062
3416 030,39561 61,379 51,379
3417 030.39571 22,382 22,302
3410 030.39575 105,969 105,969
3419 030.39577 :l(J,615 30,615
3420 030.39624 35,227 35,227
3421 030.39628 16,935 15,935
3422 030.39644 4,396 4,396
3423 030.39687 469 489
3424 030,39703 491,900 491,986
3425 030.39709 24,314 24,314
3426 030.39720 910 916
3427 030.39723 456 406
3428 030.39725 401,702 401,702
3429 030.39732 11,846 11.846
3430 030.39743 95 95
3431 000.39772 1,229 1,229
3432 030.39600 4,108 4,100
3433 030.39001 4,002 4,8B2
3434 030.39802 3,491 3.491
3435 030.39805 1,642 1,642
3436 030.39819 10,964 10,964
3437 030.39846 914 B14
3436 030.39881 2,400 2,400
3439 030.39602 1.996 1,996
3440 030.39804 6,032 5,032.
3441 030.39916 12,535 12,636
3442 030,39:917 15,134 15,134
3443 030.39916 28,077 28,077
3444 030.39927 M43 6,643
3445 00-0.39930 11,564 11.664
3446 030.39931 6,722. 6,722
3447 030.39937 11,345 11,346
ATMOS ENERGY CORPORATION, WEST1EXAS OIVISlON INTERIM COST RECOVERY ANO AATE ADJUSTMENT REPORT
PROJECT REPORT GY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
REPLACE DEEPWELL IN LUBBOCK TO IMPROVE CATHODIC PROTE;CTION DUE TD SYSTEM INTEGRITY IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN LUBBOCK TO IMPROVE CATHODIC PROTECTiON DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE :B.209 REPLACE DEEPWELL IN LUBBOCK TO IMPROVE CATHODIC PROTECTION DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN LUBBOCK TO IMPROVE CATHODIC PROTECTION DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RllLE B.209 REPLACE DEEPWELL IN LUBBOCK TO IMPROVE CATHODIC PROTECTION DUE TO svsn;M INH;GRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 605 FEET OF POLY MAJNAND 6 SERVICES AND RETIRE 505 FEET OF 2 !Net! STEEL MAIN AND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF lEXAS RULE B.209 INSTALL 3920FEETOF2 INCH POLYMAlN AND45 SERVICES AND RETIRE 3920 FEET OF 2 INCH STEEL MAIN AND 45 SERVlCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 790 FEET OF 2 INCH POLY MAIN AND 17 SERVICES AND Rl'TIRE 790 FEET OF 3 INCH STEEL MAIN AND 17 SERVlCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INST ALL 639 FEET OF 2 INCH POLY MAIN AND 6 SERVICES AND RETIRE 430 FEET OF 2 INCH STEEL MAIM ANO 6 SERVlCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
REPiACE METER SETTING AND REGULATION IN ACCORDANCE WITH RAllROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 230 FEET OF 2 INCH POLY MAIN AND RETIRE 230 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WlTH RAlLROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 1 SERVICE AND RETIRE 304FEETOF2 INCH STEEL MAJN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
INSTALL20B2 FEET OF4 INCl1 POLY MAIN AND 5567FEETOF2 INCH POLY MAIN AND 125 SERVICES AND RETIRE 7049 FEET OF VARIOUS SIZES STEEL MAIN AND 116 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITfi RAllROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE AND RETIRE 478 FEET OF 4 ~NCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE 5210 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 1200 FEET OF 4 l!;CH POLY MAIN Ar;06940 FEET OF2 INCH POLY MAJN AND 126 SERVICE;S AND RETIRE6316 FEET OF 2 INCH STEEL MAIN AND 126 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 REPLACED 130 FEET OF 2 INCH PROTECTED STEEL IP MAIN WITH 130 FEET OF 2 INCH HPDE TO CLEAR CP BREECH, REPl.ACED 1 SERVICE IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTAll 130 FEET OF 2 INCH POLY MAIN AND RETIRE 130 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 263 FEET OF 2 INCH POLY MAIN ANO 1 SERVlCE AND RETIRE 263 FEET OF2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 REBUILD REGULATOR STATION 6176 IN ACCORDANCE WITfl RAJLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF 6 INCH STEEL MAIN AND RETIRE 1 6 INCH DRESSER COUPLING IM ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0,20B REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RA!LROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 104 FEET OF 4 INCH POlYMAINAND 1 SERVICE AND RETIRE 104 FEET OF 3 INCH STEEL MAIN AND 1 SERVlCE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGUl.ATOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 REBUILD REGULA TOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUlLO REGULATOR STATION 6200 IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 REBUILD REGULATOR STATION 6219 IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 400 FEU OF 2 INCH POLY MAIN AND 12 SERVICES AND RETIRE 400 FEET OF 2 INCH STEEL MAIN AND 12 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 REPLACE 130 FEET OF 6 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL SOLAR PANE\. RECTIFIER SYSTEM IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL SOLAR PANEL RECTIFIER SYSTEM IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE e.209 INSTALL SOLAR PANEL RECTIFIER SYSTEM IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL SOLAR PANEL RECTIFIER SYSTEM IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTJ( Addlt!Oh$ Page 92 of98
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
J\LL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL- MlX
ALL- M~X
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MlX
DATE PL.Acgo IN GASPlANTIN
LOCATION f:J'U~~OSE OF PROJECT SERVICE
030 TEXAS OMS ION SYSTl'M INTEGRITY SEPTEMBER-2016
030 TEXAS DMSION SYSTEM INTEGRITY AUGUST-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS D!VISION SYSTEM INTEGRITY AUGUST· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER • 2016
030 TEXAS DIVISION SYSTl'M INTEGRITY SEPTEMBER · 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXJ\S DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST a 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DMSION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030TEXAS DIVISION SYSTEM INTEGRITY AUGUST - :m16
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DMSION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST· 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST -2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER · 2016
030 TEXAS DIVISION SYSTEM lMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVlSION SYSTEM INTEGRITY SEPTEMBER • 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST~ 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER· 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST· 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST • 2016
0:30 TEXAS DIV!S!ON SYSTEM INTEGRITY SEPTEMBER -2016
oao TEXAS DIVISION PUBLIC IMPROVEMENTS DECEMBER - 2016
oao TEXAS DIVISION SYSTEM INTEGRITY sEPTEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER- 2.010
030 TEXAS DMSION SYSTEM INTEGRITY SEPTEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
UNE ALLOCATED NO. PROJECT NUMBER COST(1) COST
3448 030.39949 3.791 3,791
3449 030.39960 23,538 23.538
3450 030.39962 25,539 25,539
3451 030.39976 43,014 43.014
3452 030.39985 472,354 472.354
3453 030.39988 465,679 465.679
3454 030.39990 22.258 22,258
3455 030.40003 29,031 29,031
3456 030.40011 755,000 755,000
3457 030.40018 2,367 2.367
3458 030.40019 1,126,044 1,126.044
3459 030.40023 576,560 576,560
3460 030.40062 4.272 4,272
3461 030.40071 23,:940 23,940
3462 030.40104 4.553 4,553
3463 030.401(]6 7,930 7,930
3484 030.40107 22.382 22.382
3465 030.40113 11.159 11.159
3466 030.40114 15,199 15,199
3467 030.40124 4,290 4,290
3468 030.40137 506.455 506.455
3469 030.40141 2,288 2,288
3470 030.40146 702 702
3471 030.40148 124 124
3472 030.40151 521.992 521,992
3473 030.40164 9,498 9,498
3474 030.40165 3.383 3,383
3475 030.40166 11.547 11.547
3478 030.40170 13.978 13,:97EI
3477 030.40171 2.731 2.731
3478 030.40172 7,722 7.722
ATMOS ENERGY CORPORJ\TION, WEST TEJ<AS DIVISION INTERIM COST ft[COVERY AND RA TE ADJUSTMENT REPOR.T
PROJECT "'PORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUllLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 635 FEET OF 2 INCH POLY MAIN AND RETIRE635 FEET OF 2 INCH ABS MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REBUILD REGULATOR STATION IN ACCORDANCE WITH RAiLROAD COMMISSION OF TEXAS RULE 8.209 REBUILD CPR REGULATOR STATION 5939 IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INST ALL 3143 FEET OF 2 INCH POLY MAIN AND 122 SERVICES AND RETIRE 3143 FEET CF 2 INCH STEEL MAIN AND 122 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 8016 FEET OF 2 ANO 4 INCH POLY PIPE TO REPLACE 2 AND 3 INCH STEEL PIPE AND 114 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 1764FEET OF 4 INCH POLY MAINA.~D 6500 FEET CF 2 INCH POLY MAIN AND 120 SERVICES AND RETIRE 4749 FEET OF 2 INCH STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALLB53 FEET OF 2 INCH PO!.Y MAIN AND RETIRE853 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 257 FEET OF 2 INCH POLY MAIN ANDRETIRE257FEET OF INCH STEEL MAIN IN ACCORDANCE WITH RA~LROAD COMMISSION CF TEXAS RULE 8.209 INSTALL 8302 FEET OF 2 INCH POLY MAIN AND 66 SERVICES AND RETIRE 8302 FEET OF 3 INCH STEEL MAIN AND 66 SER\llCES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 752 FEET OF 2 INCH POLY MAIN A.~D2 SERVICES AND RETIRE 433 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE3319 FEET 6 INCH. 8322FEET 4 INCH. 3543 FEET 3 INCH, AN02550 FEET2 INCHSTEEl WITH 12,630 FEET2 INCH, 1040 FEET 4 INCH POLY ANO 177 SERVlCES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RUl.E 8.209 INSTALL 17,485 FEETOF2 INCH POLY, 2835FEETOF 4 INCH POLY WITH 135 SERVICES AND ABANDON 17,651 FEET OF 2 INCH STE.El IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULES.209 REBUJLD REGULATOR STATlON DUE TO SYSTEM IMPROVEMENT JN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE :8.209 REPLACE 990 FEET OF 4 INCH POLY WITH 4 INCH POLY PIPE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 RETIRE REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RU!.E 8.209 INSTALL 350 FEET OF 2 INCH POLY MAIN AND 7 SERVICES AND RETIRE 350 FEET tF 2 INCH STEEL MAIN AND 7 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 250 FEET CF 1.25 INCH POLY MAIN AND 5 SERVICES AND RETIRE 250 FEET OF 2 INCH STEEL MAIN AND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL LlNEAR ANODE BED PROTECT UNPROTECTED PIPE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 322 FEET OF 2 INCH POLY IP TO CONNECT SYSTEMS AND REMOVE RS6146 DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 10 FEET OF 3 INCH STEEL MAIN AND RETIRE 1 3 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ABANDON 10010 FEET OF 2 INCH STEEL. INSTALL 7538 FEET OF 2 INCH POLY, 758 FEET OF 4 INCH POLY AND 125 FEET OF B INCH POLY. REPLACE 46 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 75 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 75 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 36 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 38 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMJSSION OF TEXAS RULE 6.209
REPLACE 6556 FEET OF 1.25 INCH. 2 INCH. AND 3 INCH STEEL MAIN WITH 2428 FEET OF 4 INCH AND 4423 FEET OF 2 INCH POLY IN ODESSA ANO INST All 150 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 380 FEET OF 2 INCH POLY MAIN AND RETIRE 380 FEET OF 2 INCH S1EEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET CF 2 INCH STEEL MAIN ANO RETIRE 20 FEET OF 2 INCH STEEL MAIN ANO 12 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 11 FEET OF S INCH STEEL MAIN AND RETIRE 11 FEET OF 6 INCH STEEL MAlN AND 1 a INCH DR.ESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 2-2 INCH DRESSER COUPLINGS IN ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RULE B.209 INST ALL 40 FEET CF 2 INCH POLY MAIN AND RETIRE 40 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RU!.E B.209 INSTALL 20FEETCF 4 INCH STEEL MAIN AND RETIRE20 FEET OF 4 INCH STEEL AND ONE -4 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WIXAddftlons Pag.e93.of9$
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALl.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
DATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRJTY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS OIVlSION SYSTEM INTEGRITY SEPTEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OECEMBER-2016
' 030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER- 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS AUGUST • 2016
030 lEXAS DMSION SVSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER- 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS m:I::EMBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST· 2016
030 TEXAS DIVlSION SYSTEM INTEGRITY AUGUST - 2015
030 TEXAS DIVlSION SYSTEM INTEGRITY DECEM!!ER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2015
030 TEXAS DIVISION SYSTEM INTEGRllY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST ~ 2016
030 TEXAS DMSION SYSTEM INTEGRITY DECEMBER· 2016
LINE ALLOGATEP NO. PROJECT NUMBER COST(11 COST
3479 0'30.40181 5,604 5,604
3480 030.40236 3,617 3,617
3481 030.40237 941 941
3462 030.40251 12,770 12,770
3483 030,40300 1,671 1,671
3484 030.4033e 966 966
3'185 030.40356 28,207 2e,207
3'186 03-0.40362 11.423 11,423
3487 030-40375 2,875 2,e75
3488 030.4037e 2,847 2,e47
3489 030.40379 3,465 3,465
3490 030.40369 77,512 77,512
3491 030.40390 2,956 2,956
3492 030.40391 3,128 3.128
3493 030,40392 2,823 2,823
3494 030.40433 2,e5e 2,85:13
3495 030.40440 2,712 2,712
3400 030.40446 37,068 37,068
3497 030.40450 10,514 10,514
3490 030.40455 975 975
3499 030.404e2 6,517 6,517
3500 030.40486 2,050 2,050
3501 030.40531 19,321 19,321
3502 030.40:532 6,314 6,314
3503 030-40551 6,227 6,227
3504 030.40569 2,851 2,851
3505 030.40609 815 e15
3500 030AOS10 15,704 15,704
3507 030.40617 7,506 7,506
3508 030.4061e 3,936 3,93S
3509 030.40019 9,940 9,940
3510 030.40620 4,e74 4,874
3511 030.40697 571,570 571.570
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION INT:ERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT Cf 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTALL 300 FEET OF 1.25 INCH POLY MAIN AND 1 SERVICE AND RETIRE 300 FO'ET OF 2 INCH STEEL MNN ANO 1 SERVICE IN ACCORPA'ICI' Will-I RAILROAD COMMISSION OF TEXAS RlJLE e.209 REMOVE REG STATION DUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILllOAD COMMISSION OF TEXAS RULE 8.209 REMOVE REG STATION PUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2e2 FEET OF 2 INCH POLY MAIN AND 3 SERVICES AND RETIRE 282 FEET OF 2 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION OUETOSYSTEM IMPROVEMENT IN ACCORDANCE WITH RAIL!lOAD COMMISSION Of TEXAS RLil.E 8,209
INST ALL 90 FEET OF 2 INCH POLY MAIN AND 2 SERI/ICES AND RETIRE 90 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPlACE REGUlATOR STATION IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE e.209 REPLACE REGUlATOR STATION 5107 QUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE e.209 REBUILD REGUlATOR STATION DUE TD SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACEMENT OF REGULATOR STATION 6032 DUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RNLROAD COMMISSION Of: TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RNLROAD COMMISSION Of TEXAS RULE 8.209 REPLACE 3030 FEET OF 2 INCH STEEL WITH POLY .216 PIPE IN ACCORDANCE Will-I RAILROAD COMMISSION OF TEXAS RUl.E 8.209 RESUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE wrrn RAILROAD COMMlSSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE Will-I RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION PUE TO SYSTl'M IMPROVEMENT IN ACCORPAMCE Will-I RAILROAD COMMISSION OF Ti=XAS RULE 8.209 REBUILD REGULATOR STATION DUE TD SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE B.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT !N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE e.2oa INSTALL 1847 FEET OF 2 INCH POLY MAIN AND 7 SERVICES AND RETIRE 1eao FEET OF 2 INCH STEEL MAIN AND 7 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
REPLACE 580 FEET 2 IN POLY DUE TO SYSTEM INTEGRl1Y IN ACCORDANCE Will-I R/\ILROAO COMMISSION OF TEXAS RULE e.209 REBUILD REGUlATOR STATION PUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE e.209 INSTALL 265 FEET OF 2 INCH POLY MAIN AND 3 SERVICES AND RETIRE 265 FEET OF 2 INCH POLY MAIN AND 3 SERVICES IN ACCORDANCE Will-I RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 190 FEET OF 2 lr-ICH POLY MAIN AND RETIRE 190FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE e.209 REMOVE RS6165, RS6255 AND RS6155 DUE TO OBSOLETE REGUlATION IN ACCORDANCE WITH RAILROAD COMMISSiON OF TEXAS RULE 8.209 REPLACE 90 FEET OF 2 INCH STEEL WITH 2 INCH POLY IN ACCORDANCE WITH RAtLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL230 FEET OF 21NCH POLY MAIN AND2 SERVICES AND RETIRE 230 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 COMBINE SYSTEM 383 WITH SYSTEM 026 AND INCREASE OPERATING PRESSURE. REMOVE RS 6154, SPOOL TOGETHER UNOER GROUND DUE TO SYSTEM IMPROVEMENTs IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 65 FEET OF 2 INC H POLY MAIN AND RETIRE 65 FEET OF 2 INCH ST.EEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUlEi 8.209 INSTALL 750 FEET OF 2 INCH POLY MAIN AND 11 SERVICES AND RETIRE 1050 FEET OF 2 INCH STEEL MNN ANP 11 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RELOCATE EXJSTlNG REGULATOR STATION DUE TO PUBLIC IMPROVEMENTS IN ACCORDANCE Will-I RAJLRDAP COMMISSION OF TEXAS RULE e.209 INSTALL 5 FEET OF 3 INCH STEEL MAIN AND RETIRE 5 FEET OF 3 INCH STEEL MAIN AND ONE 3 INCH DRESSER COUPLING IN ACCORDANCE WITH RNLllOAP COMMISSION OF TEXAS RULE a.209 INSTALL 7 FEET OF 3 INCH STEEL MAIN AND 2 SERVICES AND REMOVE 7 FEET OF 3 INCH STEEL MAIN AND ONE 3 INCH PRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 20 FEET OF 4 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH POLY MAJN IN /\CCORDANCE Willi RM.ROAD COMMISSION OF TEXAS RULE 8.209
REPLACE 9056 FEET OF 6 INCH AND 4 INCH PIPE WITH 2 INCH ANO 4 INCH POLY PIPE WITH 118 SERVJCES IN ACCORDANCE WITI-l RA~LROAD COMMISSION OF TEXAS RULE B.209
WTXAddiUon.s IJ1;1ge 94 of98
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MiX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All- MIX
ALL-MIX
ALL-MIX
ALL-MIX
OATE PLACoO IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY AUGUST - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEM!!ER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y SEPTEMBER - 2016
030 TEXAS DIVISION SYSTHM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y MAY-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030TEXAs DIVISION SYSTEM IMPROVEMENTS DECEMBER - 2016
030 TEXAs DIVISION SYsTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER- 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER-2016
0'30 TEXAS DMSlON SYSTEM IMPROVEMENTS Sl::PTEMBER • 2.016
030 TEXAS DIVJSION SYSTEM IMPROVEMENTS I SEPTEMBER-2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 201e
030 TEXAS DIVISION SYSlEM INTEGRITY SEPTEMBER- 2016
030TEXAS DIVISION SYSTEM INTEGRl1Y DECEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS SEPTEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030TEXAS DIVISION SYSTEM IMPROVEMENTS OCTOBER - 2016
030 TEXAS PIV!SION SYSTEM INTEGRITY SEiPTEMBER - 2016
03-0 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS DECEMBER - 2016
000 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTl'M INTEGRITY SEPTEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRl1Y DECEMBER - 2016
LINE ALLOCATED NO. PROJECT NUMBER COSTj1) COST
3512 OJ0.40723 566,122 566,122
3513 030.40724 45,936 45.936
3514 030.40762 2,9:66 2.986
3515 030.40756 280,650 280,650
3516 030.40757 46,677 46.677
3517 030-40789 11,783 11.763
3518 030.40803 310,254 310.254
3519 030-40837 45,839 45,839
3520 030.40838 407,060 407,080
3521 030.40839 4,234 4,234
3522 030.40852 41.775 41.775
3523 030.40853 471.446 471,446
3524 030.40859 90.094 90,094
3525 030.40660 15,630 15.630
3526 030.40001 B,076 9,o76
3527 030.40862 20,706 20,706
3528 030.40864 14,893 14,693
3529 030.40866 6,537 6,537
3530 030.40868 92,923 92,923
3531 030.40875 316,187 316,187
3532 030.40931 23,258 23,258
3533 030-40965 2,083 2,083
3534 030.40978 22,056 22,058
a53:S 030.40979 5,395 5,395
3536 030.40984 565 565
3537 030-40985 3,937 3,937
3538 030-40986 227,374 227,374
3539 OJ0.40987 145.443 145,443
3540 030.40988 295,132 295,132
3541 030-40990 79,855 79.855
3542 030-40998 5,526 5,526
3543 030.41010 7,168 7.1613
ATMOS ENERGY COiRfl'ORATION, WEST TEXAS OMS ION
INTERIM COST RECOVERY AND RATE AOJUSTMENTaEPORT PflOJECT RE"PORT CT 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 20!6 (2) BENEFITED
REPLACE 6000 FT OF 3 AND 4 INCH STEEL MMN As\ID SERVICES WITH 2 INCH POLY IN ACCORDANCE WlTH RAILROAD COMMlSSION OF TEXAS RULE 8.209 ALL- MIX INSTALL 2361 FEET OF 4 INCH POLY MAIN AND RETIRE 2331 OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL 15 FEET OF 4 INCH POLY MAIN AND RETIRE 15 FEET OF 4 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX
ABANDON 395 FEET OF 1 INCH STEEL, 886 FEET OF 1-25 INCH STEEL AND4551 FEET OF21NCH STEEL AND INSTALL5820 FEET OF 2 INCH POLY AND REPLACE 24 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX REPLACE 348FEET 3 INCH AND 240 FEET2 INCH STEEL WITH 372 FEET 4 INCH AND 305 FEET 2 INCH POLY DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 550 FEET OF 2 INCH POLY MAIN AND 4 SERVICES AND RE.TIRE 550 FEET OF 2 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 6634 FEET OF 2 INCH POLY .216 PIPE WITH 54 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX
RETIRE 2300 FEET OF 2 INCH PVC A'ID INSTALL 2300 FEET OF 2 INCH POLY DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX ABANDON 6,94a FEET STEEL PIPE AND 4, 146 FEET OF PVC AND INSTALL 11,012 FEET OF 2lN POLY AND 651 FEET OF 4 INCH POLY DUE TO SYSTEM IN1EGRl1Y IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 ALL-MIX INST All 269 FEET OF 2 INCH POLY MAIN AND RETIRE 269 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RA~LROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INST ALL 1500 F!OET OF 2 INCH POLY MAIN AND 14 SERVICES AND RETIRE 1500 FEET OF 2 INCH PVC MAIN AND 14 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 3773fT OF 3 INCH STEELAND2365 FEET OF 2 INCH STEEL MAIN WITH 3800 FEET Of 4 INCH POLY AND 2145 FEET OF 2 INCH POLY IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX
REPLACE AND LOWER 3990 FEET OF 3 INCH STEEL MAIN WITH 4 IN POLY MAIN DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 ALL-MIX INSTALL 100 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 300 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF lEXAS RULE 8.209 ALL-MIX REPLACE 2 INCH STEEL ACROSS 4TH STREET WITH 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL581 FEET OF 2 INCH POLY MAlN AND4 Sl'RVICES AND RETtRE 1102 FEET OF 4 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 All-MIX INSTALL 319 FEET OF 2 INCH POLY MAIN AND 9 Sl'RVICES AND RETIRE 360 FEET OF 4 ~NCH STEEL MAIN AND 9 SERVICES DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 76 FEET OF 2 INCHSTEEL MAIN AND RETIRE68 FEET OF 2 INCH STEEL MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 1890 FEET OF 4 INCH STEEL WITH 2 INCH POLY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 5562 FEET 2 INCH. 3 INCH. 4 INCH, AND 6 INCH. STEEL AND 43 SERVICES WITH 5515 FEET 2 INCH POLY DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUlE 8,209 ALL-MIX INSTALL 245 FEET OF 2 INCH POLY MAIN AND RETIRE 271 FEET OF 2 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 ALL-MIX INSTALL 25 FEET OF 3 INCH POLY MAIN AND RETIRE 25 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL· MIX INST ALL 6 FEET IF 4 INCH STEEL MAIN AND RETIRE 6 FEET OF 4 INCH STEEL MAIN AND ONE 4 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL- MIX RETIRE ONE 3 INCH DRESSER COUPLING IN ACCORDANCE WITH RAil.ROAD COMMISSJON DF TEXAS RULE 8.209 ALL-MIX RETIRE ONE 2 INCH DRESSl'R COUPUNG IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE DRESSER DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 5100 FEET OF 4 INCH STEEL WITH 6 IN POI. Y PIPE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.2og ALL-MIX INSTALL 2539 FEET OF 6 INCH POLY MAlN AND 15 SERVICES AND RETIRE 2539 FEET OF 6 INCH STEEL MAIN AND 15 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX INSTALL 5613 FEET OF 4 INCH POLY MAIN. 2140FEETOF2 INCH POLY MA!NAND 12 SERVICES AND RETIRE2140 FEET OF 2 INCH PVC MAIN AND 12 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX INSTALL 1149 FEET OF 4 INCH POLY MAIN ANO RETIRE 1000 FEET OF 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX INSTALL 170 FEET OF 2 INCH POLY MAIN AND RETIRE 170 FEET OF2 INCH POLY MA!N IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 ALL-MIX INSTALL41 FEET OF 2 INCH POLY MAlN ANDRETIRE25 FEET OF 2 INCH STEEL MAIN !N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX
Wtx Addltlans: IJ;j!.gl!l gs of !J8
DATE PLACcu IN
GAS PLANT IN LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVlSION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER • 201-6
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 Tl'XAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016 I
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER- 2016
030 TEXAS DIVISION PUBUC IMPROVEMENTS DECEMBl'R-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS DECEMBER-2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS DECEMBER- 2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS OCTOBER - 2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS DECEMBER - 2016 !
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DE:CEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY SEPTEMBER-2016
030 TEXAS DIVlSION SYSTEM INTEGRITY OCTOBER - 2016
030 Tl'XAS OIVlSION SYSTEM INTEGRITY OCTOBER - 2016
030 TE:H:A.S DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DlVISION SYSTEM INTEGRITY OCTOBER~2016
030 Tl'XAS DIVISION SYSTEM INTEGRITY DECEMBER~ 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVlSION SYSTEM INTEGRITY OCTOBER - 2016
LINE ALLOCATED NO. PROJECT NUMBER OOST(11 COST
3544 030-41022 9,786 9,766
3545 030.41023 887 887
3546 030,41024 2,596 2,596
3547 000-4105.2 149,823 149,823
3548 030.41056 29S.,709 293,709
3549 030.41060 34,997 34,997
35.50 OJ0.41065 13.a12 13,812
3551 030.41066" 4,584 4,584
3552 030.41072 347,782 347,782
3553 030-41073 103,323 103,323
3554 030.41089 5,039 6,039
3555 030.41188 8,639 8,6J9
3556 OJ0.411-89 8,400 a,400
3557 030.41191 23.398 2:3,398
3558 030.41199 4,592 4,592
3558 030.41200 2,229 2,229
3560 030.41202 24,597 24,597
3561 030-41204 142,550 142,550
3562 030.41235 883.561 883,561
3563 OJ0.41260 18,528 18,528
3564 030.41261 128,131 126,131
3565 030.4126'3 231.939 231.939
3566 030.41301 475,010 475,010
3567 030.41310 571,020 571,020
3568 030-41311 .9137,702 967,702
3569 030.41334 564,920 564,920
3570 030A1336 516,877 516,877
3571 030.41344 13,178 13,178
3572 030.41360 5,459 5,459
3573 030.41376 6,477 6,477
3574 030.41379 17,032 17.032
3575 030.41380 505 5-05
ATMOS ENERGY CO~PORATION, WEST TEXAS DIVISION INTERIM CO.ST RECOVERY AND RATE AOJU.S.TMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDlCATED TO PU!ll.IC USE IN CALENDAR YEAR 2016 (21
INSTALL ONE 6 INCH WElDOVER IN ACCORDANCE WITH RAILROAD COMMISSION Of"TEXAS RULE 6.209 INSTALL 1 SERVlCE AND RETIRE 65 FEET OF 211-!CH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 54J FEET OF 2 INCH POLY MAIN AND RETIRE 543 FEET OF 2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 160 FEET OF 2 INCH POLY, 1588 FEETOF2 INCH STEEL, 405 FEET OF 3 INCH STEEL AND 1131 FEET Of 6 INCH STEEL WITH 770 FEET OF 2 INCH POLY AND 1748 FT OF 4 INCH POLY WITH 7 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1230 FEET OF 4 INCH POLY AND 1166 FEET OF2 INCH POLY TO REPLACE 2 INCH AND 3 INCH STEEL MAlN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXl\S RULE 8.209 RETIRE 1700 FEETOF2 INCH PVC AND INSTALL 1700 FEET POLY AND 14 ASSOCIAlED SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.2.09 INSTALL 96 FEET OF 6 INCH POLY MAIN AND RETIRE 88 FEET OF" INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE AND R!OTIRE 115 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 4253 FEET OF POLY TO REPLACE STEEL ANO 66 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 006 FEET OF 2 INCH POLY MAIN AND 16 SERVlCES AND RETIRE 900 FEET OF 4 INCH STEEL MAIN AND 18 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL250FEETOF2 INCH POLYMAlN AND RETIRE 250 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209
REMOVE DRESSER OUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 6 FEET OF 2 INCH STEEL MAIN AND 3 FEET OF 3 INCH STEEL MAIN AND RETIRE 9 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION PF TEXAS RULE 8.209 INSTALL 25 FEET OF 4 INCH STEEL MAIN AND RETIRE 25 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 382 FEET OF 1.25 INCH POLY MAIN AND RETIRE 382 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 250 FEET OF 3 INCH STEEL WITH 2 INCH POLY PIPE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209
INSTAU. 148 FEET OF 6 INCH POLY MAIN AND 2 SERVICES AND RETIRE 100 FEET OF 8 INCH STEEL MAIN IN ACCORDANCE wm1 RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTAL.l. 310 FEET OF 4 INCH POLY MAIN 3797 FEET OF 2 INCH POLY MAIN AND 21 SERVICES AND RETIRE 1044 FEET OF 4 INCH STEEL MAIN 82. FEET OF 2 INCH STEEL MA!N 2973 FEET OF 2 INCH PVC MAJN AND 21 SERVICES IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 2'100 FEET OF 16 INCH STEEL DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 620 FEET OF4 INCH POlY MAIN AND RETIRE620 FEET OF 4 lNC'1 STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RULE 8,209 REPLACE 3250FEET OF STEEL AND 36 SERVICES WITH 2 IN POLY DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
REPLACE 2,860 FEET Of STEEL MAlN WITH 2 INCH POLY MAIN AND 17 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION DFTEXAS RULE 8.209 RETIRE 9716 FEET OF 2 INCH STEEL AND 1488 FEET OF 3 INCH STEEL AND INSTALL 11,604 FEET OF2 AND4 INCH POLY AND 73 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE8169 FEET OF 4 INCH STEEL MAIN AND INSTALL 3520 FEET OF 4 INCH POLY AND 5854 FEET OF 2 INCH POLY AND 158 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 12,236 FEET OF 2 INCH POLY, 7,854 FEET OF 4 INCH POLY, 170 SERVICES AND 172 METERS. ABANDON 21,238 FEET OF STEEL AND RANDOM PE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE e.209 REPLACE 7713 FEET OF21N, 41N, BIN, BIN STEEL AND PE AND39 SERVICES WITH 6305 FEET 2 INC'1 POLY DUE TO svsn;M INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 7420 FEET OF STEEL WffH 8800 FEET OF POLY, 100 SERVICES, RETIRE 3 REG STATIONS AND REPLACE ONE REG STATION DUE TO SYSTEM INTEGRITY iN ACCORDANCE WITH RAILROAD COMMISSiON OF TEXAS RULE 6.209 INSTALL 301 FEET OF 2 INCH POLY MAIN AND RETIRE 400 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WiTH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD METER SETTING DUE TD SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 6,209 INSTALL 26 FEET OF 2 INCH POLY MAIN AND RETIRE 26 FEET OF 2 INCH STEEL MAiN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
INSTALL 565 FEET OF 2 INCH POLY MAIN AND 3 SERVICES AND RETIRE 573 FEET OF 2 INCH STEEL MAJN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 WELDOVER IN ACCORDANCE WITH RAILROAD COMMISSION OF T<l<AS RULE 8.209
WTX Ad-dition:5 Page 96 of98
CUSTOMERS BENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
Al..L-MIX
OATE PLACED IN GAS PLANT IN
LOCATION PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER-2016 I !
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER- 2016 I
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER ~ 2016
030 TEXAS DlVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION PUBLIC tMPROVEMENTS DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS OMS ION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER -2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY OCTOBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
oao TEXAS DIVISION SYSTEM INTEGRITY OCTOSER • 2016
I 030 TEXAS DIVISION SYSTEM INTEGRITY DECEM!lER - 2016
030 TEXAS DIVISION SYSTEM !NTEGR!TY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY O~Cl::MBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEM!IER - 2016
030 TEXAS DIVISION SYSTEM lNTEGRITY DECEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DMSION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMB!OR - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY NOVEMBER-2016
030 TEXAS DlVISION SYSTEM IMPROVEMENTS DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2011!3
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
LINE ALLOCATED NO. PROJECT NUMllER COST(1) cmrr
3576 030.41385 210,2114 210,244
3577 030.41386 181,103 181,103
3518 030-41399 7,169 7.169
3579 030.41400 2,841 2,841
3580 030.41412 2,471 2,471
3581 030.41424 482 482
3582 030.41438 3.285 3,285
3583 030.41455 223.375 223,375
3:584 030.41470 10,727 10,727
3585 030.41557 2,069 2,069
3586 030.41569 136,014 136,014
3587 030.41576 124,298 124,298
3566 030-41586 142,351 142,351
3589 030-41592 39,149 39,149
35•0 030.41595 10,022 10,022
3591 030-41597 281,043 281,043
3592 030.41634 184,837 1B4,637
3593 030.41635 142.863 142,863
3594 030.41636 125,899 125,S9.9
3595 030.41650 121.118 121,118
3596 030.41670 1,577 1,677
3:597 030.41671 31,394 37,394
3598 030,41672 40.4!Ml 40,409
3599 030.41675 22,367 ;22,367
3600 030.41677 349,243 349,243
3601 030.41683 1,699 1,699
3602 030.41684 42,653 42,653
3603 030.41686 43,246 43,246
3604 030.416:89 45,711 45,711
3605 030.41694 37,367 37,J67
3606 030.41696 41,829 41.829
ATMOS ENERGY CORPORATION, WESTTEXAS DIVISION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2010
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 201fi (21
REPLACE 2487 FEET OF 4 INCH STEEL AND 28 H'ET OF 4 INCH POLY WITH 2811 FEET OF 2 INCH POLY AND 76 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 1835 FEET OF 4 INCH STEEL WITH2882 FEET OF 2!NCH POLY WITI-j 45 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXl\S RULE 8.209 REPLACE REGULATOR STATION AND METER SET DUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE OBSOLETE AT RISK REGULATION AND METER SETDUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE B.209 INSTALL 841 FEET OF 2 INCH POLY MAIN A~D 22 SERVICES AND RETIRE 841 FEET Of 1 JNCH STEEL MAIN AND 22 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 5 FEET OF 2 INCH STEEL PIPE AND REMOVE DRESSER DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 20 FEET OF STEEL WITH POLY PUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
REPLACE APPROX 4180 FEET OF STEEL MAJN AND 17 SERVICES WITH 2 IN POLY DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL372 FEET OF 2 INCH POLY MAIN AND RETIRE372FEET OF 2. INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 456 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 584 FEET OF 1 INCH STEEL MAlN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RllLE 8.209 REPLACE 124 FEET OF 2 INCH AND 1100 FEET OF 3 INCH STEEL WITH 124 FEET OF 2 INCH AND 1008 FEEff OF 4 INCH POLY AND REPLACE 10 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 143 FEET OF 2 INCH AND 1497 FEET OF 3 INCH STEEL WITH 172 FEET OF 2 INCH AND 1579 FEET PF 4 INCH POLY AND REPl-ACE 13 SERVICES DUE TO SVSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 REPLACE 2785 FEET OF 4 INCH STEEL WITH 2476 FEET OF 2 INCH POLYWITH60 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 REPLACE ONE OEEPWELL DUE TD SYSTEM INTEGRllY IN ACCORDANCE wnH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE ANO LOWER SHALLOW 2 INCH STEEL MAJN ACROSS HWY 54 AT BLAIR STREET DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE w1m RAil.ROAD COMMISSION Of TEXAS RULE 8.209
REPLACE 5300 FEET OF 3 IN STEEL MAJN Wl'lH 2 IN po;.y AND52 SERVICES DUE TO SYSTEM INTEGRITY ;N ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8,209 REPLACE2511 FEET OF 4 INCH STEELWITH2513 FEET OF 2 INCH POLY WITH 78 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 2524 FEET PF 4 INCH STEEL, 90 FEET OF 4 INCH POLY AND 823 FEET OF 5 INOH BARE STEEL PIPE WITH 2490 FEET OF 2 INCH POLY AND BO SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXA9 RULE B.209
RETIRE 4082 FEET OF PVC AND INSTALL4110FEET OF2 INCH POLY MAIN AND 2B ASSOCIATED SERVICES IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE B.209 RETIRE 407 FEET Of 2 INCH STEEL MAIN AND 4307 FEET OF PVC MAIN AND INSTALL 6167 FEET OF 2 INCH POLY MAIN AND 43 ASSOCIATED SERVICES IN ACCORDANCE WITI-j RAJLROAO COMMISSION OF TEXAS RULE 8.200 REPLACE DEEPWELL IN HEREFORD DUE TO SYSTEM INTEGRITY IN ACCORDANCE WffH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELL IN LUBBOCK DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXl\S RULE 8.209 REPLACE DEEPWELLIN LUBBOCK PUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 LOWER AND REPLACE 125 FEET Ci INCH PE WITH 175 FEET 6 INCH POLY DUE. TO PUBUC iMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2!Ml RETIRE3633 FEET OF 3 INCH STEEL AND 3376 FEET OE= 4 INCH STEEL AND INSTALL 7609 FEET Of 2 INCH POLY AND90 ASSOCIATED SEFMCES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXl\S RULE 8,209 REPLACE DEEPWELLIN LUBBOCK DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DEEPWELl IN LUBBOCK DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.200 REPLACE DEE;PWELL IN AMARILLO DUE TO SYSTEM INTEGRITY IN ACCORDANCE Wlrn RAlLROAD COMMISSION OF TEXAS RULE 6.209 REPLACE DEEPWELL IN HARTLEY COUNTY DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE DEEPWELl IN MIDLAND DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE PEEPWELL IN MIDLAND DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
WTX Additions P.a;ge 97 of98
CUSTOMERS llENEFITED
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MlX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All.-M~
ALL· MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL· MIX
ALL-MIX
ALL-MIX
OATE PLACoD 1N GAS PLANT IN
LOCATION: PURPOSE OF PROJECT SERVICE
030 TEXAS DIVISION SY8TEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER • 2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER -2016
030 TEXAS DIVISION SYSTEM IMPROVEMENTS DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
000 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY otcE:MBER - 2016
o:m TEXAS DIVISION SYSTEM !NlEGRITV DECf;MBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER- 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXl\S DIVISION SYSTEM INTEGRITY DECEMBER-2018
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2018
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION PUBLIC IMPROVEMENTS DECEMBER· 2016
030 TEXAS PIVlSION sYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DIVlSION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 20115
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER· 2016
030 TEXAS DIVISION SYSTEM INTEGRlTY DECEMBER • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER u 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER -2016
030 TEXAS DIVlSION PUBLIC IMPROVEMENTS DECEMBER·2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRllY DECEMBER - 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER - 2016
0:30 TEXAS OMS ION SYSTEM INTEGRITY DECEMBE;R • 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
030 TEXl\S DIVISION SVSTE;M INTEGRITY DECEMBER~ 2016
030 TEXAS DIVISION SYSTEM INTEGRITY DECEMBER-2016
LINE NO.
3607
3608
31509
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
::m;m
3621
3622
3623
3624
3625
3626
3627
3628
3629
3830
3631
3632 3633
3634
~ ~ ~ ~ ~
ALLOCATED PROJECT NUMaER COST[1} COST
030.41698 4,936 4.938
030.41699 42,987 42,987
030.41701 46,613 46,613
030.41705 9,188 9,168
030.41707 42,357 42.J57
030.41708 41,010 41.010
030-41709 38,027 38,027
030.41711 120,912 120,912
030-41715 93,106 93.106
030-41740 7,760 7.760
030.41799 137,184 137.184
030.41822 12,004 12,004
030.41049 225.324 22li,324
030.41861 5,573 5,573
030.41883 119,421 119,421
030.41694 188,464 188,464
030,4189;1~ 149,757 14•,757
030.41909 330,591 330,591
030.41967 138,409 138,409
030.42036 28,646 28,646
030.42038 2a,a57 28,857
030-42078 11,012 11,012
030-42060 96,985 96,965
030.42163 60.000 50,000
030.42173 66,807 66,807
TOTAL TEXAS RULE 8.209 PROJECTS
jLN. •28· LN. 36311 5:;t,449.68B 53,449,688
TOTAL ALL WEST TEXAS ADDITIONS
{LN. 54 + LN. 524 + LN. 3632) B0,710,074 e.0.6(}7,453
NOTES:
ATMOS ENER.GYCOR.PORATION, WESTTfXAS DIVIS.ION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO CUSTOMERS PUBLIC USE IN CALENDAR YEAR 2016 (2) BENEFITED
REPLACE DEEPWELL IN GRAY COUNTY DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 ALL-MIX REPl-ACE DEEPWELL IN AMARILLO DUE TO SYSTEM INTEGRITY IN ACCORDANC!O WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE DEEPWELL IN AMARILLO DUE TO SYSTEM lNTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE OEEPWELL IN PAMPA DUE TO SYSTEM lNTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE DEEf'WELL IN BIG SPRING DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 ALL·MlX REPLACE DEEPWELL IN BIG SPRING DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE DEEPWELL IN BIG SPRING DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8,209 ALL· MIX REPLACE 1B80 FEET OF 3 lNCH AND 41N UNPROTECTED STEEL AND PE AND 19 SERVICES WITH 1760 FEET 2 INCH POLY DUE TO SYSTEM INTEGRITY lN ACCORDANCE WITH RAILROAD COMMISSlONOFTEXAS RULE 8.209 ALL-MIX REPLACE 4072 FEET OF PVC WITH 2 IN POLY DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE OBSOLETE METER AND REG IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 2348 FEET OF 4 INCH STEEL WITH 2360 FEET OF 2 INCH POLY WITH 49 SERVICES DUE TD SYSTEM INTEGRllY IN ACCORDANCE wm-t RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE REGULATOR STATION DUE TO SYSTEM IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 ALL- MIX RETIRE 8189 FEETOF2 INCHSTEEL MAIN AND INSTALL 7799 FEET OF 2 INCH AND 4 INCH POL y AND as ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All-MIX
RELOCATE 302 FEET Of 2 INCH POLY WITH 302 FEET Of POLY WITH ONE SERVICE DUE TO SYSTEM IMTEGRITV IN ACCORDANCE WITH RAll-ROAO COMMISSION Of TEXAS RULE 8.209 ALL-MIX REPLACE 584 FEET OF 3 INCH STEEL, 1436 FEET OF 2 lNCH STEEL AND 308 FEET OF 2 INCH POLY WITH 578 FEET OF 4 INCH POLY AND 1266 FEET OF 2 INCH POLY AND REPLACE 38 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WffH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX RETIRE 5942 FEET OF 2 INCfl STEEL MAlN AND 626 FEET OF 2 INCH POLY MAIN AND INSTALL 5987 FEET OF 2 INCH POLY MAIN AND 25 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 #N/A REPLACE 1305 fEET OF 2 INCH STEEL AND 121 FEET OF 2 INCH POLY WITH 1876 FEET OF 2 INCH STEEL AND REPLACE 12 SERVICES DUE TO SYSTEM IMTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REMOVE 9600 FEET OF 2 INCH STEEL AND REPLACE WITH 8300 FEET OF 4 INCH POLY AND 3 ASSOCIATED SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WlTH RAILROAD COMMISStON OF TEXAS RULE 8.209 ALL- MIX INSTALL 2930 FEET OF 2 INCH POLY WllH 69 SERVICES AND ABANDON OF 2708 FEET OF 4 INCH STEEL, 25 FEET OF 6 INCH STEEL AND 410 FEET OF 4 INCH POLY DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8_209 ALL-MIX RETIRE 500 FEET OF 4 INCH STEEL AND INSTALL 600 FEET OF 2 INCH POLY AND 4 ASSOCIATED SERVICES DUE TO SYSTEM INTEGRl1Y IN ACCORDANCE WITH RAILROAD CDMMlsmoN OF TEXAS RULE 8.209 ALL· MIX RETIRE 1635 FEET OF 2 INCH STEEL MAIN AND INSTALL 1719 FEET OF 2 INCH POLY MAIN AND 3 ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE 266 FEET OF 2 INCH AaS WITH 266 FEET Of 2 INCH POLY WITH ONE SERVICE DUE TO SYSTEM INTEGRl1Y IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 ALL-MIX REPLACE355 l=EETOF POLY PIPE AND 2524 FEET OF 4 INCH STEEL PIPE WITH 2083 FEET OF 2 INCH POLY PiPE WITH 59 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RULE 8.209 ALL-MIX
REPLACE 390 FEET OF 3 INCH STEEL AND 1278 FEET OF 2 INCH STEEL WITH 390 FEET OF 4 INCH POLY AND 1278 FEET OF 2 INCH POLY DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 6.209 ALL-MIX REPLACE 1620 FEET MAIN WITH POLY ANO REPLACE 17 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 All· MIX
{'1) The ''COST'' column reflect$ lhe eapila;l~ed pm1io.l'I of 1he cost ol"!Jy_
LOCATION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS D!VISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISiON
030TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030TEXAS DIVISION
030 TEXAS DIVlSION
030 TEXAS DIVISION
{2) The "DESCRIPTION OF COMPLETED PROJtC'J'S 01:;.0ICA'l'E:.b 10 f:'IUl3LIC USE. IN CALENDAR YEAR 2016'' oo~umn describes caplla.lf.zed casls only.
WIX Additions Paee-98 af9.S
DAlc. PLACED IN GAS PLANT IN
PURPOSE OF PROJECT SERVICE
SYSTEM INTEGRITY Dl::CEMBER ~ 2016
SYsn;M INTEGRITY DECEMBER· 2016
SYSTEM INTEGRITY DECEMBER-2016
SYSTEM INTEGRITY DECEMBER- 2016
SYSTEM INTEGRITY DECEMBER- 2016
SYSTEM INTEGRITY DECEMSER ~ 2016
SYSTEM INTEGRITY DECEMBER-2016
SYSTEM INTEGRITY DECEMBER-2016
SYSTEM INTEGRITY DECEMBER-2016
GROWTH DECEMBER.2".J16
SYSTEM INTEGRITY DECEMBE;:R - 2016
SYSTEM IMPROVEMENTS DECEMBER - 2016
SYSTEM INTEGRITY DECEMBER· 2016
SYSTEM INTEGRITY DECEMBER-2016
SYSTEM INTEGRITY DECEMBER - 2016
S"!'SlEM ~NTEGRHY DECEMBER - 2016
SYSTEM INTEGRITY DECEMBER· 2016
SYSTEM INTEGRl1Y DECEM!IER - 2016
SYSTEM INTEGRITY DECEMBER - 2016
SYSTEM !NTEGRllY DECEMBER-2016
SYSTEM INTEGRITY DECEMBER-2016
SYSTEM INTEGRITY DECEMBER-201.S
SYSTEM INTEGRITY DECEMBER- 2016
SYSTEM INTEGRITY DECEMBER ~ 2016
SYSTEM INTEGRITY DECEMBER - 2016
ATMO.S [NEftGV CORPORATION, WESTTEXAS DIVl510~ INTERIM COST :RECOVERY ANO RATE ADJUSTMENT REPORT
PROJECT REJl'Oftr C'f 2016
LINE No. PROJIOCT NUMBER COST(1) ALLOCATED
COST DESC:RlPTION OF COMPLETED PROJECTS DEDICATED TO
PUBLIC USE IN CALENDAR YEAR 2016 (21
1
2
_..L_ __L_
5 6
7
8
9
10
11
12
13
14
15 16
17
1a
19 20 21
22
23
24
25
26
27
2a
29
30
31
32
33
34
35
36
37
Sa
39
40
41
42
95.42%
WEST rEXAS GENERAL OFFJCE. RETIREMENTS PER BOOKS - DIV1SfON 010 ADM!N 030 (235.791 (224,9•11 RETIREMENTS. TRANSFERS & ADJUSTMENTS
TOIAL WEST TEXAS GENERAL OFFICE -
DIVISION010 RETIR!OMENTS
ALLOCATED@. 95.42% [LN.11 1235.7911 {224,981)
WEST TEXAS - All OTHER DIVISIONS RETIREMENTS PER BOOKS 0:30.17285 (7501
030.17510 (aa)
030.17673 [28,001)
030.18BOO [634
030.18601 (56.48a)
030.16800 12,004)
030.19267 169
030.19306 [275)
030.19330 1571
030. 19578 (2,5821 030.19683 (1,6981
030.19690 (756)
030.19941 132,0191
030.23444 14531
030.24340 (451) 030.28141 (141
030.34514 [O)
030.35349 {91
030.35361 110,146'
030.35385 [7.4121
030.35367 14,0601
030.35368 m
030.35371 (183)
030.35374 (34f
030.35375 1661
030.35376 [2.961)
030.35380 (76af
030.35382 (23,4461
030.353a6 13)
030.35367 (0)
030.35:392. 12,4521
030.35394 (8,2631
030.35399 11321
030.36401 l35i
030.35403 [31
030.35405 1851
030,35406 11791
(750) RETIRE MO FEET OF 2 INCH STEEL MAIN DUE TO SYSTEM INTEGRITY INSTALL 400 FEET OF 2 INCH POLY MAIN AND RETIRE 400 FEET OF 2 INCH
!Ba) STEEL MAIN DUE TO SYSTEM INTEGRITY LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN 8 INCH DtAMETER,
(28,0011 ANODES. METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACEIRETlRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER,
(634) ANODES, MElERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TAsKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER,
(56,48a) ANODES, METERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE T AsKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF!-ESS THAN 8 INCH DIAMETER,
{2,0041 ANODES, METERS, REGULATORS AND METER LOOPS INSTALL 591 FEET OF 6 !NCH POLY MAIN AND RETIRE 406 FEET OF 8 INCH
[69) STEEL MAIN DUE TO PUBLIC lMPROVEMENT INSTALL 300FEET OF4 INCH POLY MAIN AND RETIRE300 FEETOF6 INCH
(275] STEEL MAIN DUE TO SYSTEM lNTEGRITV REROUTE 50 FEET OF 12 INCH STEEL MAIN DUE TO RELOCATION REQUEST
[57] FOR FiRST BAPTIST CHURCH
(2.5a2) RETIRE 3796 FEET OF 2 INCH AND 4 INCH MAIN DUE TO SYSTEM INTEGRITY (1.698) RETIRE 425 FEET OF 2 INCH MAIN AND 19 SERVICES
INSTALL 1SOFEETOF3 INCfl POLY MAIN AND1 SERVICE AND RETIRE 180 (756) FEET OF 3 INCH STEEL MAIN AND 1 SERVICE DUE TO SYSTEM INTEGRITY
SEMINOLE OPERATIONS SLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FE;ET TO 99 FE!OT OF LESS THAN 8 INCH DIAMETER,
[32.019) ANODES. METERS. REGULATORS AND METER LOOPS INSTALL 207 FEET OF 6 INCH POLY MAIN ANO RETIRE 207 FEET OF 6 INCH
1453) STEEL MAIN M51) RETIRE 220 FEET OF 2 INCH STEEL MAIN DUE TO SYSTEM INTEGRITY (14 RETIRE 1 1 INCH SERVICE DUE TO SYSTEM INTEGRITY
INSTALL 770 FEETOF6 INCHPOLY MAIN ANO 1 SERVICE AND 1 NEW
'° REGULATOR STATION DUE TO SYSTEM IMPROVEMENT
SEMINOLE/BROWNFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, P!PE 5 FEET TO 99 FEET OF LESS THAN 8 INCH
{9} DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LlNES, PIPE 5 FEET TO 99 FEET OF LESS 11-lAN 8 INCH DIAMETER,
~10,146) ANODES, METERS, REGULATORS AND METER LUBBOCK OPERATIONS SLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER,
17,412 ANODES, METERS, REGULA TORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PlPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER,
(4,060) ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACBRETIRE TASKS: SERVICE LINES, PIFE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER,
(3 ANODES, METERS, REGUlATORS AND METER LOOPS LITTLEFIELD OPERATlONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER.
[183 ANODES, METERS, REGULATORS AND METER LOOPS PLAINVIEW OPERATIONS BLAN.KET TO COVER REPtACEJRETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO S9 FEET OF LESS THAN a INCH DIAMETER.
(34) ANODES, METERS, REGUlATORSAND METER LOOPS LUBBOCK OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND
(66) REGULATORS DUE TO CUSTOMER GROWTH PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE L!NES. PIPE o FEET TO 99 FEET OF LESS THAN a INCH DIAMETER.
1'2,961 ANODES, METERS, REGULATORS ANO METER LOOPS LUBBOCK OPERATIONS BLANKET FOR NEW SERVICE UNES, METERS AND
(768 REGULATORS DUE TO CUSTOMER GROWTH AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER.
(23,446) ANODES, METERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER.
!3) ANODES, METERS. REGULATORS AND METER LOOPS PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF lESS THAN a INCH DIAMETER, ANODES.
(0) METERS. REGULATORS AND METER LOOPS
(2,452)
(8,263)
[132
(35)
13
(a5)
f179
HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER. ANODES, METERS, RE:GUlATORS AND METER LOOPS PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLAC8RE.TIRE TASKS: SERVICE LINES, PIPE :5 FEET TO 99 FEET OF LESS THAN 8 lNCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, P!PE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PJPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER. ANODES, METERS. REGULATORS AND METER LOOPS BIG SPRING OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 9S FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
SEMINOLE/BROWNFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES. METERS, REGULATORS AND METER LOOPS
SEMINOLE/BROWNFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE UNES. PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER. ANODES, METERS. REGULATORS ANO METER LOOPS
WTX Retireme-nts Pagl!l"1of 11
I
CUSTOMERS BENEFITED
ALl-MlX
ALL-MIX
ALL- MIX
All" MfX
ALL" MIX
All-MIX
All-MIX
All-MIX
ALL-MIX
ALL-MIX
All-MIX ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX ALL-MIX ALL-MIX
All-MIX
ALL-MIX
All-MIX
All-MIX
ALL-MIX
All-MIX
All-MIX
ALL- MIX
All" MIX
All-MIX
ALL-MIX
ALL, MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL, MIX
ALL"MIX
ALL-MIX
ALL-MIX
ALL-MIX
All-MIX
LOCATION
I 030TEXAS DIVISION!
030 TEXAS DIVISION
030 TEXAS DMS!ON
030 TEXAS DIVfSiON
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TElV\S DIVISION
030 TEXAS DIVISION
030 TEXAS DMSION
030 TEXAS DIVISION 030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION 030 TEXAS DIVISION 030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
000 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVlslON
PURPOSE OF PROJECT
ADMIN 030
SYSTEM INTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGR!TY
SYSTEM INTEGRITY
SYsTEM INTEGRITY
SYSTEM INTEGRITY
SYSTEM IMPROVEMENTS
SYSTEM lNTEGRITY
SYSTEM lM.PROVEMENTS
SYSTEM INTEGRITY SYSTEM INTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGRITY SYSTEM INTEGRITY SYSTEM INTEGRITY
SYSTEM IMPROVEMENTS
SYSTEM INTEGRlrf
SYSTEM INTEGRITY
sYSTEM INTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGRITY
GROWTH
SYSTEM INTEGRITY
GROWTfl
SYSTEM INTEGRITY
SYSTEM !NTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGRllY
SYSTEM JNTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGRITY
ALLOCATED LINE NO. PROJECT NUMBER COST(1J COST
43 030.35410 (131,401) (131,401
44 030.35439 (89.655 (89,655)
45 000.35440 (7,002) (7,002)
46 030.3544, lno.021 f726,821)
47 030.35442 (6571 (657)
48 030.35444 147.376 (47,376)
49 030.35445 (3.025) 13,0251
50 030.35446 113.514) (1M14)
51 030.35447 (331) 13311
52 030,35449 1271,869) (271,869)
53 030.35451 151.535 (51,535)
54 030.35453 {24.697) 124,rum
55 030.35454 (55.945) [55,945)
56 030.35456 (4.9'26) 14.9261
57 OJ0.35467 !56,250) (56,2501
58 030.35458 (141,119) 1141,119]
59 030.35459 (742,224) [742.2241
60 030.35460 1267,313) (267.313)
61 030.35461 (540) (540)
62 030.35463 1136,689) [100.689)
63 030.35464 1310,9501 1310.950)
64 030.35465 (32,7511 132.7511
65 030.35467 (2,337) [2.337)
66 030.35473 (200,1171 1200,117)
67 030.35496 (20,737) 120.737
BB 030.35505 15,483' 15,483)
69 030.36534 (24,704) 124.704
70 030.35541 (10,952) 110.952
71 030.35542 (1,246) (1.246)
72 OS;0,35546 (37,2031 137,203)
73 030.35552 (306) 1306
74 030.35553 (906,9491 (906.949)
75 030,35570 134,2911 134,291)
76 030.35573 (18,335) (1B.335\
77 030.35574 11,48~) (1AB4)
78 030.35576 (87,752 187.7521
79 030_35578 (175) (175]
A'rM05 ENERGY CORPORATION, W[.ST TEXAS DIVISION INTERIM COST REOOVCRY ANO RATE ADJUSTMENT REPORT
PROJECT REPORT CV 4016
DESCRIPTION OF COMPLEl.ED PROJECTS DEDICAlt:O l'O PUBLIC USE IN CALENDAR YEAR 2016 (2)
AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PJPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS. REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BlANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/llETIRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH D!AMETER, ANODES. METERS. REGULATORS AND METER LOOPS LUBBOCK OPERATlONS BLANKET TO COVER REPLACEillETiRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FE.El oi:t LESS IHAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/llETIR!O TASKS: SEORVICE LINES, PIPE 5 FEET TO 99 FoET OF LESS THAN 8 INCH DIAMEToR, ANODES. METERS, REGULATORS AND METER !.OOPS LUBBOCK OPERATIONS BLANKET TO COVER REPlACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET DF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LU!:IHOGK oPi=RAJIONS aL.ANKe1 ro COVER REPl.ACEIRET!RE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANOD~S. ME"l'ERS, N:E.GUL.ATORS AND METER LOOPS LITILEFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEETT099 FEET OF LESS THAN 8 INCH DIAMETHR, ANODES. METERS, REGULATORS /\ND METER LOOPS LITTLEFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, A="llODES, METERS, REGULATORS AND METER LOOPS LITTLEFlELD OPERATIONS BLANKET TO COVER REPLACEfRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PLAINVIEW OPERATIONS BLANKET TO COVER RE.PLACEIRETJRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS AM/\RILLO OPERATIONS BLANKET TO COVER REPLACElllETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LODPS PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER. ANODES. METERS. REGULATORS AND METER LOOPS HEREFORD OPERATIONS BLANKET TO COVER REPlACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER. ANODES, METERS. REGULATORS /\ND METER LOOPS PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS /\ND METER LOOPS BIG SPRING OPERATIONS BLANKET TO COVER REPLACEIRET1RE TASKS: SERVWE LINES, Pltrt=. 5 FEET IO 6'9 FEET OF LESS THAN 8 ]NCH DIAMETER, ANODES, METERS, RE:.GUL.ATORS AND METER LOOPS PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER. ANODES, METERS. REGULATORS AND METER LOOPS
SEMINOLEIBROWNFIELD OPERATIONS BLANKET TD COVER REPLACEJRETIRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PLAINVIEW OPERATIONS BLANKET TO COVER REPLACEIRET!RE TASKS: SERVICE UNES, FIPE 5 FEET TO 99 FEET OF LESS lHAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BL/\NKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER. ANODES, METERS. REGUlATORS AND METER LOOPS PA.'iJ!PA OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS: SER\nCE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER. ANODES, METERS. REGULATORS AND METER LOOPS LUBBOCK OFERATIONS BLANKET TO COVER REPLACEfRETIRE TASXS: SERV!CE LlNES, PIPE 5 FEET TO 99 FEET OF LESS Tl-lAN B INCH DIAMETER, ANODES, METERS, REGUlATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS LUBBOCK OPERATIONS BLANKET TO COVER REPLACEIRETIRE TASKS; SERV!CE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER. ANODES, METERS. REGULATORS AND METER LOOPS AMARlLLO OPERATIONS BL/\NKET TO COVER GROWTH TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS /\ND METER LOOPS PAMPA OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND REGULATORS DUE TO CUSTOMER GROWTH PLAINVIEW OPERATIONS BLANKET TO COVER REPL.ACEfRETlRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS PLAINVIEW OPERATIONS BLANKET TO COVER REPLACEJRETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FoET OF LoSS THAN 8 INCH DIAMETHR. ANODES, METERS. REGUlATORS AND METER LOOPS AMARJLLO OPERATIONS BL/\NKETTD COVER REPLACE/RETIRE TASKS:. SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACElllETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METHRS. REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/llETIRE TASKS: SERVICE; LINoS. PIPo 5 FEET TO 99 FIOET OF LESS THAN 8 INCH DIAMETER, ANODE;$, METERS. REGUlATORS AND METER LOOPS AMARILLO OPERATIONS BLANKETTO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANDDEs, METERS, REGULATORS AND METER LODPS AM/\RILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANDDES, METERS. REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPo 5FEETTO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS. RoGULATORS AND METER LOOPS PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS TI-IAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LDOPS
WTX Rt!tlreme1tts P.;;igoel of11
CUSTOMERS BENEFITED LOCATION PURPOSE OF PROJECT
ALL-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DMSJON SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SVSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVIS~ON SYSTEM INToGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL.MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL·MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL·MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL·MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM lt>HEGRllY
ALL-MIX 030 TEXAS DIVISION GROWTH
ALL-MIX 030 TEXAS DIVISION GROWTH
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 THXAS DIVISION SYSTEM JNTEGRITY
/\LL·MIX 030 TEXAS DIVISION SYSTEM JNTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INToGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM l~'fEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM l~TEGRm'
LINENO.
80
81
82
83
84
65
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102 103
104
105
105
107
108
109 110 111
112
113
114
115 116
~ 118
119
120
121
122
123
124
125
126
ATMOS. ENERGY CORPORATION, WEST TEXAS DMSION INTERIM COST l'IEC:OVFRY ANO RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
ALLOCATED om=scf?.tPTION om:: COMPLElED l=',l:lOJECl:s DEDICATED TO
PROJECT NUMBER COST(1)
030.35579 (244.803)
030.35!;82 168,804)
030.a65B5 (9,317)
030.35589 (34,968)
030.35590 (1.235)
030.35591 [11,906)
030.35593 (51,564
030.35594 [413)
030.35595 148,728l
030.35597 (137,924)
030.35599 1677)
030.35801 [18,3941
030.35604 [4,053)
000.35605 1191
03-0.35608 (13,794f
030,36418 (431
030.38155 [9,269)
030.38504 (65)
030.38507 (43)
030.38512 (63,984)
030.385~ (103)
030.39279 !11
030.39367 (1)
030.39538 (243)
030.391562 112,276l
030.38784 !1,0561
030.40031 1596l
030.40523 (5,530)
030.4015:38 11,030l
0:30.40997 112,681 030,41341 1180 0:30.41359 (105,666
030.41551 [95
0:30.41584 (31,980)
/\DMIN030 (2.1:;6,812)
TOTAL WEST TEXAS -AUL OTHER DIVISIONS
RETIREMENTS (LN. 6-LN.114) (7,684,693)
RETIREMENTS • TElt'AS RULE 8.209 PROJECTS
030.27037 (1.622)
030.27850 (9)
030.30596 [20)
030.31200 '66)
030.31260 166)
030.31927 110)
0:30.32221 [66)
030.32342 [00)
COST PUBLIC USE IN CALENDAR YEAR 2016 (2) PAMPA OPERATIONS BLANKET TO COVER REPlACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES,
[244,803) METERS, REGUlATORS AND METER LOOPS PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES,
(68,804) METERS, REGUlATORS AND METER LOOPS PAMPA OPERATIONS BLANKET TO COVER REPlACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES,
(9,317l METERS, REGUlATORS AND METER LOOPS PAMPA OPERATIONS BLANKET TO COVER Rl:;Pl.ACl:YRt=.TIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODES,
(34.966) METERS, REGULATORS AND METER LOOPS AMARILLO OPERATIONS BLANKETTO COVER REPlACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER,
11,235) ANODES, METERS, REGULATORS AND METER LOOPS HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER.
(11,906) ANODES, METERS, REGULATORS AND METER LOOPS HEREFORD OPERATJONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEETT099fEETOFLESS THAN 8 INCH DIAMETER,
(51,5641 ANODES, METERS, REGULATORS AND METER LOOPS PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER,
[413) ANODES, METERS, REGULATORS AND METER LOOPS PERMIAN !IAS!N OPERATIONS !ILANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER,
(48,728) ANODES. METERS, REGULATORS AND METER LOOPS PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LIESS THAN 8 INCH DIAMETER,
(137,924) ANODES, METERS, REGULATORS AND METER LOOPS BEG SPRING OPERATIONS BLANKET TO COVER REPLACEIRETJRE TASKS: SERVlCE LINES, PIPE 5 fEET TO 99 FEET OF LESS 11-IAN 8 INCH DIAMETER,
(677) ANODES, METERS, REGULATORS MID METER LOOPS BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER,
[18,394 ANODES, METERS, REGULATORS AND METER LOOPS BtG SPRING OPERATIONS BlANKE.T TO COVER REPLACE/RETIRE TASKS; SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B lNCH DIAMETER,
(4,053) ANODES, METERS, REGULATORS AND METER LOOPS
SEMINOLEIBROWNFIELD OPERATIONS BLANKET TD COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN 8 INCH
(19) DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS
SEMINOLE/BROWNFIELD OPERATIONS BLANKET TO GOVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH
(13.794) DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS
INST All. 80 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 95 FEET [43) OF2 INCH STEEi. MAlN AND 1 SERVICE DUE TO PUBLIC IMPROVEMENTS
REPLACE AND RELOCATE FACILITJES: lNSTALL 733 FEET Of S INCH POLY MAIN ANO RETIRE 394 FEET OF 4 INCH POLY MAIN DUE TO PUBLIC
19,269 IMPROVEMENT PAMPA OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS AND
165 REGULATORS DUE TO CUSTOMER GROWTH HEREFORD OPERATIONS BLANKET FOR NEW SERVICE LINES, METERS ANO
[43 REGULATORS DUE TO CUSTOMER GROWTH BIG SPRING OPERATIONS BLANKET TO COVER REPlACEIREHRt: TASKS: SERVI Ct UNES, Pl PE 5 FEET TO 99 FE:ET OF LESS THAN 8 INCH DIAMETER,
(63.984) ANODES, METERS, REGUlATORS AND METER LOOPS
(103) INSTALL4300 FEET OF 4 INCH POLY MAlN DUE SYSTEM IMPROVEMENTS RETIRE 1900 KAWASAKI MULE: FOR USE BY WEST TEXAS DIVISION
(1) EMPLOYEES REBUILD MEASUREMENT STATION AND TRANSWESTERN TAKEOFF DUE TO
(1) SYSTEM IMPROVEMENT (243) REBUILD METER SETI1NG DUE TO S't'STEM IMPROVEMENT
INSTALL 2B!l2 FEET OF 4 INCH Pol Y MAIN AND RETIRE 2692 FE!OT OF 2 INCH (12,276) Pol. Y MAIN DUE TO SYSTEM IMPROVEMENT
(1.056) RELOCATE 564 FEET OF 3 INCH STEEL MAIN DLJE TO PUBLIC IMPROVEMENT REl.OCATE 298 FEET OF 2 INCH STEEl. MAIN AND 1 SERVICE WITH '398 FE;ET
!596) OF 2 INCH POLY MAIN DU!; TO PUBLIC IMPROVEMENT lNSTAlL676 FEET OF 2 INCH POLY MAIN AND RETIRE 3494 FEETOF2 INCH
(5,530) STEEL MAIN AND 145 SERV!CES OUE TO PUBUC lMPROVEMENT INSTALL 440 FEET OF 4 INCH POLY MAIN AND 1 SERVICE ANO RETIRE 220
11.030) FEET Of 3 INCH PE MAIN DUE TO svsn;M IMPROVEMENT INSTALL 257 FEET OF 4 INCH POLY MAIN AND RETIRE 162 FEET OF 3 INCH
112,681) STEEL MAIN DUE TO SYSTEM IMPROVEMENT 1180) RETIRE 3 FEET OF 2 INCH POLY M/\IN DUE TO SYSTEM INTEGRITY
!105,665) RETIRE 1 FORKLIFT FOR USE BY WEST TEXAS DIVISION EMPLOYEES REPlACE 120FTOF3 INCHSTEEL PIPE WITH 150FEETOF4 INCH POLY DUE
1951 TO PUBLIC IMPROVEMENTS INSTALL 5805 FEET DR 4 INCH POLY, 1 SERVICE AND REGULATION AND
IJ1,•80l RETIRE 4760 FEET OF 2 INCH POLY AOMIN WORK ORDER FOR COMPANY 030 FOR USE WITH TRANSFERS AND
(2,1:J6,812J RETIREMENTS
(7,8•4.693)
RETIRE 758 FEET OF 2 INCli STEEL MAlN IN ACCORDANCE WITH RAILROAD (1,622) COMMISSION OF TEXAS RULE 8.209
REPlACE 1 SERVICE IN ACCORDANCE WITH RAil.ROAD COMMISSION OF [9) TEXAS RULE B.209
(201
(66)
(66)
(10)
(66)
(66)
RETIRE 1 SERVICE IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULEB.209 RET~RE 1 SERVICE lN ACCORDANCE Wl1H .RAILROAD COMMISSION OF TEXAS RULEa.209 RETIRE 1 SERVICE IN ACCORDANCE WITfl RAil.ROAD COMMISSION OF TEXAS RULEH.209 RETIRE 2 IDLE SERVICES IN ACCORDANCE WlTH RAILROAD COMMISSJON OF TEXAS RULE B.209 RETIRE 1 SERVICE IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULEB.2.09 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE8.209
W1X Retlrem@nts Page 3 af11
CUSTOMERS BENEFITED LOCATION PURPOSE OF PROJECT
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DMSION SYSTEM INTEGRITY
All-MIX 030 IEXAS DMSlON SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM l~'lEGRITY
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM JNTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MiX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL - MIX 030 TEXAS DIVISION PUBLIC IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION PUBLIC IMPROVEMENTS
RESIDENTIAL 000 TEXAS DIVJSION GROWTH
RESIDENTIAL 030TEXAS DIVJSION GROWTH
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL·MIX 0'30 TEXAS OMS ION SYSTEM IMPROVEMENTS
/\LL·MlX 0'30 TEXAS DIVISION EQUIPMENT
AUL-MIX 030 TEXAS DMSION SYSTEM IMPROVEMENTS
AUL-MIX 030 TEXAS DMSJON SYSTEM IMPROVEMENTS
ALL·MlX 030 TEXAS DMSJON SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS D!VISION SYSTEM IMPROVEMENTS
/\LL-MIX 030 TEXAS DMSION PUBLIC IMPROVEMEl>ITS
ALL-MIX 030 TEXAS OIVJSION PUBl.IC IMPROVEMENTS
/\LL·MlX 030 TEXAS DMSJON SYSTEM IMPROVEMENTS
ALL-MJX 030 TEXAS DIVISJON PUBLIC IMPROVEMENTS
ALL-MIX 030 TEXAS DMSJON SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVlSlON EQUIPMENT
ALL-MIX 030 TEXAS OMS ION PUBLIC IMPROVEMENTS
ALL-MIX 03-0 TEXAS DIVJSION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DMSION EQUIPMENT
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRtlY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM ll>ITEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 0:30 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALLOCATED LINENO. PROJECT NUMBER COST[11 COST
127 OJ0_33687 l20,684l (20,6641
126 030.33841 /S6l {66)
129 030.33842 (JJl {33)
130 030.34365 (651) 1651]
131 030.34424 (540) (540)
132 030.34573 (1691 {1B9
133 030.34690 (318) (318)
134 030,34754 {75.135) (75,135)
135 030.35027 (4.566) {4,5851
136 030.35257 (138.154) (136,1541
137 030.35258 (4.145) {4,145)
138 030_352.60 (85) {65)
139 030.35261 (1,023) (1.0Zl)
140 030.35263 (520) (620)
141 030.36284 {101 (10)
142 03-0.35265 (57,641) {57,641)
143 030.3526"6 {253,215} (25",215)
144 030.35269 (4,767) (4.767)
145 03-0.35274 (1,504} (1.504)
148 o:m.35275 (17,7421 (17.742)
147 030.35276 {161,711) . (161.711)
148 030,35278 (1,7571 (1,767)
149 030.35200 (956) {956)
150 030.35263 1382,963) (362,963)
151 030.35267 (44,950) (44,950)
152 030.35288 1123,6001 (12a.886)
153 030.35299 (17,8341 {17,634)
154 030.35290 (75,6931 (75,393)
155 030.35:l91 (27,677} (27,677)
168 030,35292 (440,883) (440.663)
157 030.35293 (28,593) {28,593)
ATMOS !:NERGV C:OFIPORATION, WESTTE:AA$ OMSION INHA.IM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT Rf PORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEOICATED TO PUBLIC USE IN CALENDAR YEAR 2016 [2)
INSTAU. 10 FEET OF 2 INCH Pol. Y MAIN AND 1 SERVICE AND RET!RE 10 FEE:T OF 2 INCH PLASTIC MAlN AND 1 SER.VICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCOROANCE WITH RAILROAO COMMISSION OF TEXAS RULES.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULES.209 RETIRE 303 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 2683 FEET OF 2 INCH POI. Y MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 148 FEET OF 2 INCH POLY MAIN ANO RETIRE 146 FEET OF 2 INCH STEEL MAIN ANO REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULEB.209 INSTALL 7964 FEET OF 2 INCH POLY MAIN ANO 7 SERVICES AND RETIRE 7900 FEET OF 2 INCH PLASTIC MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS lHAN B INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS IN ACCCOROANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER. ANODcS, METERS. REGULATORS AND METER LOOPS IN AOCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 LUBBOCK OPERATIONS Bl..ANl<ET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. Pl PE 5 FEET TO 99 FEET OF LESS WAI; 6 INCH DIAMETER. ANODES. METERS, REGULATORS AND METER l.OOPS IN ACCCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 8.209 LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICEUNES, PIPE 5 FEET TO 99 FEET OF l.ESS THAN 6 INCH DIAMETER, ANODES. METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 lJTilEFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TAsKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES. METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVlCE UNES. PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES. METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 6.209 PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE UNES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 AMARILLO OPERATIONS BLANKET TD COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 6 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND ME:TER LOOPS IN ACCCORDANCE WITH RAfLRDAD COMMISSION OF TEXAS RULE B.209 AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN AOCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS~ SERVlCE LINES, PIPE 5 FEET TO 99 FEET Of LESS THAN a INCH DIAMETER, ANODES. METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS TI-lAN :e INCH mAMETER, ANODES, ME1ERS, REGULATORS AND METER LOOPS IN ACCCDRDANCE Wlll-l RAILROAD COMMJSSION OF TEXAS RULE 8-209 HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS, REGULATORS /\ND METER LOOPS IN AcCCORDANCE WITK RAILROAD COMMISSION OF TEXAS RULE 8.209 PERMIAN BASIN OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND Ml~.TER LOOPS lN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 B!G SPRlNG OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS lN ACCCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 8.209
SEMINOLE/BROWNFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES. PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER. ANODES, METERS, REGULATORS AN!l METER LOOPS IN l\CCCORDl\NCE WITfl RAl!ROAD COMMISSION OF TEXAS RULE "-209 LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 6 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TcXAS RULE 8.209 LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS. REGULATORS AND lllETER LOOPS IN ACCCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 LITTLEFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS; SERVICE LINES, PIPE 5 FIOET TO 99 FEET OF LESS lHAN a INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCOROANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 LITTLEFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS, REGULATORS AND ME1ER LOOPS IN ACCCDRDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 PLAINVIEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS IN AOCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 PLAINVlEW OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 AMARILLO OPERATIONS BLANKET TO COVER REPLACEJRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN 8 INCH DlAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 AMAA;LLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
WTX Retirements Piiig-e 4 ofll
CUSTOMERS BENEflTEO LOCATION PURPOSE OF PROJECT
ALL-MIX 030 TEXAS DIVlSION SYSTEM INTEGRllY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRllY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 03-0 TEXAS DIVISION SYSTEM INTEGRflY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
At.L-MIX 030 "TEXAS DIVISION SYS1EM IN1EGRITY
ALL- MIX 030 TEXAS DIVISION SYS1EM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SYS1EM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRl'N
ALL-MIX 030 TEXAS DIVlS~ON SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRffY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
Al.L-MIX 03-0 TEXAS DIVlSION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRtTY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL·MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL·MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
AUL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
AUL·MlX 030 TEXAS DIVISION SYSTEM INTEGRITY
AUL·MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DIVISION SVSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL·MIX 030 TEXAS DIVISION SYSTEM INTEGRllY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIViSION SYSTEM INTEGRITY
ALL-MIX 03-0 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVlSIDN SYSTEM INTEGRITY
LINENO. PROJE;CT NUMBER COST(1)
158 030.35294 (18)
159 030.35296 (94,791)
160 030.35297 (37,774}
161 030.35302 (20,158}
162 030.35303 (11,9901
163 030.35304 (411.123)
164 030,35306 (101,7911
165 030.35309 (59,951)
166 030.35412 (401)
167 030.35645 (16,305)
168 030.36474 (40,259)
169 030.36668 (21,838)
170 030,36866 [60,778)
171 030.36968 [40,349)
172 030.37374 (56,792)
173 030.37539 [34,764)
174 030.37761 [35,761)
175 030.37048 (1,061)
176 030.38003 (13,979)
177 030.38023 (50)
178 030.38062 [063)
179 030.38148 (9,729)
180 030.38161 (11,604)
181 030.38185 (8,991)
182 030,38195 (50,148)
103 030.38199 (8,4391
184 030.38202 (1,463)
185 030.38204 (2)
186 030,38218 (48)
187 030.382.47 (341)
188 030.38346 (29,506)
189 030.38371 (3,511)
190 030.38384 (6)
191 o:m.aa4os (4,390)
192 030.38412 (8,662)
193 030.38433 (48)
ALLOCATED COST
[18)
[94,791)
[37,774)
[2.0,158)
(11,990)
[411,123)
[101,791)
(59,961)
(4011
(16,305}
(40,259}
(21,8301
(60,7701
(40,349)
(56,792)
(34,764)
(35,751)
(1,061)
(13,979)
(50)
(863)
(9,729)
(11,604)
(8,991)
[50,148)
(8,439)
(1,463)
ATMOS ENERGY CORPORATION, WEST TEXAS D!VISIDN INTE;RIM COST l'lfCOVE"RY ANO RATE AOJUSTME"NT REPORT
PROJECT REPORT CY 2.016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUB UC USE IN CALENDAR YEAR 2.016 (2]
AMARILLO OPERATIONS SLANKET TO COVER REPLACl'/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET Of LESS THAN B INCH DIAMETER. ANODES, METERS. REGULATORS AND METER LOOPS IN ACCCOROANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 PAMPA OPERATIONS SLANKET TO COllER REPLACEIRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS ANO METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 PAMPA OPERATIONS BLANKET TO COVER REPlACEIRETlRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXA.S RULE B.20.9 HEREFORD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 HEREFORD OPERATIONS Bl.ANKH TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES. METERS. REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 PERMIAN BASIN OPERATIONS BLANKETTO COVER REPLACEJRETIRE TASKS: SERVICE LINES, P'JPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS lN ACCCORDANC~ WITH RAILROAD COMMJSSION OF TEXAS RULE 8.209 BIG SPRING OPERATIONS BLANKET TO COVER REPLACEfRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TD 99 FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS !N ACCCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209
SEMINOl.EIBROWNFIELD OPERATIONS BLANKETTO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 LlnLEFIELD OPE;RATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH 011\METER. ANODES, MET!ORS, REGULATORS AND METER LOOPS IN ACCCORDANCE WfTH RAILROAD COMMISSION Of Tl'XAS RULE 8.209 LUBBOCK OPERATIONS BLANKET TO COVER REPLACEfRETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET Of LESS THAN 8 lNCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 10225 FEET OF 2 INCH POLY MAIN AND RETIRE 10225 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAilROAD COMMISS[ON OF TEXAS RULE 8.209 RETIRE 44,856 FEET OF 3 INCH ABS DUE TO SYSTEM INTEGRfTY IN ACCORDANCE WfTH RAll-RAOC COMMISSION OF TEXAS RULE 8.209 INSTALL 4530 FEET Of 2 INCH POLY MAIN ANO 7 SERVICES AND RETIRE 4530 FEET OF 2 INCH STEEL MAIN AND 7 SERVICES lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 3700 FEET OF 2 INCH POLY MAIN WITH 15 SERVICES AND RETIRE 3700 FEET OF 2 INCH EGGSHELL PIPE IN ACCORDANCE Wl"!H RAILRAOO COMMISSION OF TEXAS RULE 8_209 INSTA!.L4.'J26 FEET OF 2 INCH POLY, 2965 FEET OF 4 INCH POLY WITH 117 SERVICES AND RETIRE 4536 FEETOF2 INCH PVC, 743 FEET OF 2 INCH STEEL MAIN AND 1989 FEET OF a INCH STEEL IN ACCORDANCE WITH RAILROAD COMMMISSION OF TEXAS RULE 0.209 INST ALL 3195 FEET OF 2 INCH POLY MAIN, 5020 FEET OF 1.25 INCH POLY WITH 2 SERVICES AND RETIRE 24,550 FEET OF 2 INCH PVC MAIN IN ACCORDANCE WITH RAILRAOD COMMISSION OF TEXAS RULE 8.209 INSTALL 11,091 FEET OF 2 lNCH :POLY .MAIN WITH 180 SERVICES AND RET1RE 13,482 FEET OF 4 INCH AND 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSJON OF TEXAS RU!....t 8.209 RETIRE 1250 FEET OF 2 INCH STEEL M/\lN IN ACCORDANCE; WITH RAILROAD COMMISSION OF TEXAS RULE a.209 INSTALL 3275 FEET OF 4 INCH POLY MAIN ANO RETIRE 3322 FEET OF 3 INCH STEEL M/\lN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 3m; FEET OF 2 INCH POLY MAIN ANO RETIRE 1926 FEET OF 8 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 160 FEET OF 2 INCH STEEL IN ACCORDANCE WITH RAILROAD COMMISSlON OF TEXAS RULE 8.209 INSTALL 5656 FEET OF 2 INCH POLY MAIN AND RETIRE 1006 FEET OF 2 INCH ABS, 717 FEETOF'2 INCH POLY MAIN. 3570FEETOF2 INCHPVC IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2471 FEET OF 2 INCH POLY MAIN AND 13 SERVICES AND RETIRE 1607 FEET OF 2 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209 INSTALL 419 FEET OF 6 INCH STEEL MAIN AND RETIRE 419 FEET Of 6 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8,209
INSTALL 12,675FEET OF 16 INCH STEEL MAIN AND 00 FEET OF 6 INCH STEEL MAIN AND 1 REGULATOR STATION ANO RETIRE 12,000 FEET OF 16 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 2B FEET OF 8 INCH STEEL MAIN, 28 FEET OF 0 INCH POLY MAIN AND RETIRE 28 FEET OF 8 INCH STEEL MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 225 FEETOF8 INCH STEEL MAIN AND RETIRE225 FEET OF 8 INCH STEEL MAlN IN ACCORDANCE WITH RAILRAOO COMMlSSION OF TEXAS RULE 0.209 REBUILD REGULATOR STATION DUE TD SYSTEM IMPROV<;MENT IN
(2) ACCOROA.~CE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
RETIRE 240 FEET OF 2 INCH POLY MAIN AND 24673 FEET OF 2 INCH PLASTIC (48) MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 0.209
RETIRE 30 FEET OF 2 INCH POLY MAIN AND 2 SERVICES IN ACCORDANCE (341) WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 1319 FEET OF21NCH POLY MAIN Ar.ID RETIRE 1325 FEET OF 2 INCH PLASTIC MAIN AND REPLACE 1 SERVICE IN ACCORDANCE WITH RAILROAD
[29,506) COMMISSION OF TEXAS RULE 8.209 RETIRE 590 FEET OF 2 INOH PVC MAIN IN ACCORDANCE WITH RAILROAD
{3,511) COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE AND RETIRE1 SERVICE IN ACCORDANCE WITH RAILROAD
(6) COMMISSION OF TEXAS RULE 8.209 INST ALL 654 FEET OF 4 INCH POLY MAIN WITH 4 SERVICES AND RETIRE 327 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
(4,390) OF TEXAS RULE a20g. INSTALL 6,400 FEET OF 2 INCH POLY MAIN AND 33 SERVICES AND RETIRE 6,400 FEET OF 3 INCH STEEL MAIN AND 33 SERVICES IN ACCORDANCE WITH
(0,662) RAILROAD COMMISSION OF TEXAS RULE 6.209 RET!RE 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF
[48) TEXAS RULE 8.209
WT.IC Retirements: P:age 5of11
CUSTOMERS BENEFITED LOCATION PURPOSE OF PROJECT
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITI"
ALL-MIX 030 TEXAS DiVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTE.M INTEGRITY
ALL-MIX 030 TEXAS DIV!SlON SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SVSTEM INTE;GRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTE;GRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DiVISION SYSTEM fNTEGRlTY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALIL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DiVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM !NTEGFUTY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MD< 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM !NTEGRHY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 1EXAS DMSION SYSTEM INTEGRllY
LINE NO. PROJECT NUMBER COST(1J
194 030.38434 (7)
195 030.38464 [778)
196 030.38495 j53)
197 030.38496 (1,7•0)
198 030.38497 (2,348)
199 030.38498 {712)
200 030.38499 (24)
201 030.38503 (412)
202 030.38506 (11)
203 030.38508 (239)
204 030.38510 (15,6531
205 030.38511 (1121
206 030.38513 (14.574)
207 030_38514 (16,8031
208 030_38529 (34,906)
209 030.38537 [2,152)
210 030.3856-0 (21.640)
211 030_38574 (31,921)
212 030.38575 (12,189)
213 030.38581 (18,000J
214 030.38588 (166.61")
216 030.38716 (132)
216 030.38800 {9.039)
217 030.30811 (6,674)
218 030.38877 [28)
219 030.38967 (26,676)
220 030.39010 (7)
221 030.39045 [2,411)
222 030.39075 (125.478)
223 030.39112 (16)
224 030.39121 [2,108)
225 030.39143 (383)
ALLOCATED COST
ATMOS ENERGY CORPOMTION, WEST TEXAS DIVISION INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECTREPORTCY2016
DESCRJPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CAL.ENOAR YEAR2016 (2)
RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS (7) RULE B.209
RETIRE 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS (778) RULE 6.209
LUBBOCK OPERATIONS BLANKET TO COVER REPLACEIRETIRE LAS KS: SERVICE LINES, PIPE 5 FEET TO 99 FEE:T OF LESS TI-lAN a INCH DIAMElER, ANODES, METERS, REGULATORS AND METER LOOPS JN ACCCORDANCE WITH
(53) RAILROAD COMMISSION OF TEXAS RULE 8.209 LUBBOCK OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH
(1,790) RAILROAD COMMISSION OF TEXAS RULE 8.209 \.llBBOCK OPERATIONS B\.ANKET TO COVER REPLACEIRIOTIRE TASKS: SERVICE LINES. PIPE 6 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER. ANODES. METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH
[2.348) RAILROAD COMMISSION OF TEXAS RULE 8.209 LITTLEFIELD OPERATIONS BLANKET TO COVER REPlACEIRETJRE TASKS: SERVtCE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITH
(712) RA3lROAD COMMISSION OF TEXAS RULE 6.20S PLAINVIEW OPERATlONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LlNES, PlPE5 FEET TO 99 FEET OF LESS THAN B INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDANCE WITI-:1
[24) RAILROAD COMMISSION OF TEXA.S RULE 8.209 AMARILLO OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS; SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN a INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN AccCDRDANOE WITH
(412) RAILROAD COMMISSION OF TEXAS RULE 6.209 PAMPA OPERATIONS BLANKET TO COi/ER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET Of LESS THAN 8 INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOFS IN ACCCORDANCE WITH
[11) RAILROAD COMMISSION Of TEXAS RUU~ 8.209
PERMIAN BASIN AREA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER. ANODES, METERS, REGULATORS AND METER LOOPS IN
(239) ACCCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
PERMIAN BASIN AREA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TAsKS: SERVICE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 8 INCH DIAMETER. ANODES. METERS, 11:E:GULATOR8 AND METER LOOPS lN
[15,653) ACCCORDANCE WITH RAILROAD COMMISSION OF 1EXAS RULE B.2.09 BIG SPRING OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SERVICE LINES, PIPE 5 FEETT099FEET OF LESS THAN 8 INCH DIAMETER, ANODES, METERS, REGULATORS AND METER LOOPS IN ACCCORDMICE WITH
(112) RAILROAD COMMISSION OF TEXAS RULE 8.209 BIG SPRlNG OPERATIONS BLANKET TO COVER REPLACEIREHRE TASKS: SERVICE LINES, PIPE 5 FEET TO :!il9 FEET OF LESS THAl•.J 8 INCH DIAMETER, ANODES. METERS, REGULATORS AND MElER LOOPS IN ACCCORDANCE WJTK
{14.574) RAILROAD COMMlSSION OF TEXAS RULE 8.209
SEMINOLE/BROWNFIELD OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: SER~CE LINES, PIPE 5 FEET TO 99 FEET OF LESS THAN 6 INCH DIAMETER, ANODt:S, METERS, REGULATORS AND ME1ER LOOPS IN
j16,803) ACCCORDllNCE wrrn RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1983 FEET OF 3 INCH POLY MAlN IN ACCORDANCE WITH RAILROAD
P4,906l COMMISSION OF TEXAS RULE 8.209 INSTALL 100 FEET OF2 INCHAND 6496FEET OF 4 !NCH POLY MAIN AND 23 SERVICES AND RETIRE 30 FEET OF 2 INCH AND 7556 FEET Of 3 INCH PLASTIC AND 275 FEET OF 3 INCH STEEL MAtN AND 23 SERVICES IN ACCORDANCE
(2.152) WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 0420 FEETOF3 INcH POLY MAIN AND RETIRE 6420 FEET OF 3 INCH STEEL MAIN AND R~lACt 76 SERVlCES !N ACCORDANCE WITH RAltROAD
(21,640) COMMISSION DF TEXAS RlJLE 8.2<l9 INSTALL 6879 FEET OF 2 AND 4 INCH POLY MAIN AND RETIRE 6879 FEET OF VARIOUS SIZE STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION
(31,921) OF TEXAS RULE 8.209 INSTALL 7273 FEET OF 2 INCH POLY MAIN AND 7 4 SERVICES AND RETIRE 3123 FEET OF 4 INCH STEEL MAlN AND 4022 FEET OF 3 INCH STEEL MAIN AND 74 SERVICES lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
(12.189) 8.209 INSTALL 11155 FEET OF 2 INcH POLY MAIN AND 219 SERVICES AND RETIRE 9483 FEET OF 2 INCH AND 226"4 FEET OF 3 INCH STEEL MAIN AND 219 SERVICES IN ACCORDANCE WJ~ RAllROAD COMMISSION OF TEXAS RULE
(18,000) B.209 INSTALL 10020 FEET OF 2 INCH POLY MAIN AND 56 SERVICES AND RETIRE 10020 FEET OF 2 INCH PLASTIC MAIN AND 56 SERVICES IN ACCORDANCE
(166,619) WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM iMF'ROVEMENT IN
{132) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUL.E 8.209 INSTALL 5506 FEET OF 2 INCH AND 3695 FEET OF 4 INCH POLY MAIN AND 3 SERVICES AND RETIRE 5750 FEET OF 2 INCH AND 3265 FEET OF 3 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION DF
(9,0"9) TEXAS RULE 8.209 INSTALL 100FEET OF 1.25 INCH. 7000 FEET OF 2 INCH. AND869 FEET OF 4 INCH POLY MAIN AND 66 SERVICES AND RETIRE 6043 FEET OF VARIOUS SIZE STEEL MAIN AND 56 SERVICES IN ACCORDANCE WITH RAILROAD
(6,674) COMMISSION OF TEXAS RULE 8.209 RETIRE 243 FEET OF 3 INCH AND 45 FEET DF 2 INCH STEEL MAlN AND 75 FEET OF 2 INCH POLY MAlN IN ACCORDANCE WITfl RAILROAD COMMISSION OF
(28) TEXAS RULE 8.209 RETIRE 18.732 FEET OF 2 INCH ABS MAIN IN ACCORDANCE WITH RAILROAD
(25,676) COMMISSION OF TEXAS RULE 8.209 REBUILD CPR SETIING IN ACCORDANCE WITH RAILROAD COMMISSION OF
(7) TEXAS RULE 8.209
(2.411)
(125,478)
(16)
(2,108)
[383)
RELOCATE 550 FEET Of 3 INCH STEEL MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 22,500 FEET OFG INCH POLY MAIN AND 430:8 FEET OF2 INCH POLY MAIN AND 1 REGULATOR STATION AND RETIRE 30,000 FEET OF 12 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 379 FEET OF 2 INCH POLY MAIN DUE TO IN ACCCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL B FEET OF VARIOUS SIZE PIPE AND RETIRE lWO VALVE NEST DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 330 FE~l Oi=:' 2 INCH POLY MAIN AND RETIRE 330 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WffH RAILROAD COMMISSION OF "TEXAS RULE 8.209
WTX Rt!tirements PaseG o-f11
CUSTOMERS BENEFITED LOCATION PURPOSE OF PROJECT
ALL-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 IEXAS DIVISION SYSTEM !NlEGRl"lY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL~MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
ALL-MlX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL·MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DlVJSION SYSTEM INTEGRITY
All-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 0:30 TEXAS DMSION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
/\LL-MIX oao TEXAS PlVlSION SYSTEM INTEGRITY
All-MIX 030 TEXAS DMSION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
Al!.-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
All-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DNISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALLOCATED LINENO. PROJECT NUMBER COST(1) COST
226 030.39153 (42.409) (42,409)
227 030.39177 i527) (527)
228 030.39183 1486} (486)
229 030.39188 1462) (462)
230 030.39194 (15} i15J
231 030.3921.S (1.9201 (1,920)
232 030.39264 (4,9121 (4.912)
233 oao.39285 (23.111) (23,111)
234 03o_39200 (57,3551 {57.355)
235 030.39294 (524) (524)
236 030.39302 (11.702) 111.702)
237 030.3'9304 (22,221) (22.221)
238 030.39374 (232) j232)
239 030.39379 (202) 1202)
240 030,3:9365 (724) 1724)
241 030.39386 (239) 1239)
242 030.39390 (94) (94}
243 030,39415 (565) (5851
244 030.39432 (183) (1631
245 030.39456 (242) (242)
246 030.39517 (347) (347f
247 030.39531 17.417) (7.417)
248 030.39534 (5,756) {5.75BJ
249 030,39571 (490) (490)
250 03-0.39575 (2.556) {2.556)
251 030.39577 [146) (146)
252 030.39624 (8.914) {8.914)
253 03-0.39644 (159) (159)
254 030.39687 (165) (185)
255 030.39703 (3,231) {3,231)
256 0:30,39709 (46) (46)
257 030.397'20 (344) (344)
258 030.39723 (7.197) [7.197)
259 030,39725 j6.423) (6,423)
260 030.39732 (1,197) (1.197)
261 030.39743 (182) (182}
2a2 030.39752 {13) (13)
ATMOS .ENERGY CORPORATION, WEST TEXAS DIVISION INTE~IM (:0$T .RECOVERY ANO RATE ADJU.STM~NT ;REPOR:T
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJf:;CTS Dt;DICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INSTAll32El8 FEET OF 2.lNCH POLY MAIN 7487 FEET OF 2 INCH POLY MAIN AND 35 SERVICES AND RETIRE 10,851 FEET OF 2 INCH PVC MAIN AND 35 SERVICES IN ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE 8.209 lNSTALL 7082 FEET OF 2 INCH POLY MAIN AND 70 SERVICES AND REnRE 7082 FEET OF 3 INCH STEEL MAIN AND 70 SERVICES IN ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 360 FEET OF 2 INCH STEEL MAIN AND 7 SERVICES AND RETIRE 360 FEET OF 3 INCH STEEL MAIN AND 7 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 432 FEET Of 4 INCH POLY MAIN AND 4 SERVICES AND RETIRE 460 FEET OF 4 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE wm; RAILROAD COMMISSION Of TEXAS RULE 8.209 RETIRE 2800 FEET Of 2 INCH PLASTIC MAIN DUE TO IN ACCCORDANCE wrrn RAfLROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 173 FEET OF 4 INCH POLY MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 750 FEET OF 2 INCH POL V MAIN AND RETIRE 750 FEET OF 2 INCH PLAST[C MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULEB.209
INSTALL 615 FEET OF 4 lNCH POLY MAIN AND 5886 FEET OF 2 INCH POLY MAIN AND 106 SERVICES AND RETIRE 7708 FEET OF VARIOUS SIZES STEEL MAIN AND 111 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULEB.209 INSTALL 3585 FEET OF 4 INCH POLY MAIN AND 6510 FEET OF 2 INCH POLY MAIN AND 138 SERVICES AND RETIRE 41 B4 FEET OF PVC MAIN AND 138 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 360 FEET OF 2 INCH POLY MAIN AND RETIRE 360 FEET OF 2 INCH OF STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INST ALL 6036 FEET OF 2 INCH POLY MA!N AND 6244 FEET OF 4 INCH POLY AND 63 SERVICES AND RETIRE 11,597 FEET OF PVC MAIN AND 63 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 10,980 FEET OF 2 lNCH AND 425 FEET OF 4 INCH STEEL WITH 10,940 FEET 2 INCH AND 525 FEET 4 INCH POLY AND 224 SERViCES DUE TO SYSTEM INTEGRITY IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE B.209
INSTAll 60 FEET OF 2 INCH POLY MAIN AND RETIRE 60 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 147 FEET OF 2 INCH POLY MAIN AND RETIR!O 147 FE!OT Of 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL 1040 FEEfOF 2 POLY STEEL MAIN AND 5 SERVICES AND RETIRE 1040 FEET OF 2 ~NCH STEEL MAIN AND 5 SERVICES lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 162 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 48 FEET OF 4 lNCH STEEL MAIN AND RETIRE 38 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL 788 FEET OF 4 INCH POLY MAIN AND 11 SERVICES AND RETIRE 788 FEETOF3 INCHSTEEl MAIN AND 11 SERV[CES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8:209
REPLACE DEEPWELL IN WASHBURN TO IMPROVE CATHODIC PROTECTION IN ACCORDANCE WITH RAil.ROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 101 FEET OF 4JNCH POLY MAIN AND 1 SERVICES AND RETJR;E: 150 FEET OF 4 INCH STEEL MAIN AND 1 SER~CE tN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 104 FEET OF 4 INCH POLY MAIN ANO RETIRE 120 FEET OF 4 INCH STEEL MAIN AND 1 SER~CE IN ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 42 FEET OF 3 INCH STEEL MAIN AND 5&8 FEET OF 5 INCH STEEL MAIN AND 135 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 755 FEET OF 5 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WiTH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 5793 FEET OF 2 INCH POLY MAIN AND 53 SERVICES AND RETIRE 5793 FEET OF 2 INCH STEEL MAIN AND 53 SERVICES IN ACCORDANCE WfTH RAILROAD COMMISSION DF TEXAS RULE 8.209 INSTALL 505 FEET OF POLY MAIN AND 5 SERVICES AND RETIRE 505 FEET OF 2 INCH STEEL MAIN AND 5 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 3920 FEET OF 2 INCH POLY MAIN ANO 45 SERVICES ANO RETIRE 3920 FEET OF 2 INCH STEEL MAIN AND 45 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 790 FEET OF 2 INCH POLY MAIN ANO 17 SERVICES AND RETIRE 790 FEET OF 3 INCH STEEL MAIN AND 17 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 639 FEET OF 2 INCH POLY MAtN AND 6 SERVICES AND RETIRE 438 FEET OF 2 INCH STEEL MAIN AND 6 SERVICES IN ACCORDANCE WITf-1 RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 230 FEET OF 2 INCH POLY MAIN AND RETIRE 230 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WlTH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE AND RETIRE 3-04 FEET OF 2 INC'1 STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 IMSTALL 2062 FEET OF 4 INCH POLY MAIN AND 5567 FEET OF 2 INCH POLY MAIN AND 125 SERVICES AND RETIRE 7649 FEET OF VARIOUS SIZES STE;EL MAIN AND 115 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REBUILD REGULATOR STATION DUE TD SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1 SERVICE AND RETIRE 478 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200
INSTALL 5 FEET OF 2 INCH POLY MAIN AND RETIRE 5210 FEET OF 2 INCH ABS MA!N IN ACCORDANCE: WITH RAILROAD COMMlSSION OF TEXAS RULE 6.209 INSTALL 1200 FEET OF 4 INCH POLY MAIN AND 6940 FEET OF 2 INCH POLY MAIN AND 126 SERVICES ANO RETIRE 6316 FEET OF 2 lNCH STEEL MAIN AND 125 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE8.209 REPLACED 130 FEET OF 2 INCH PROTECTED STEEL IP MAIN WITH 130 FEET OF 2 INCH HPDE TO CLEAR CP BREECH, REPLACED 1 SERVICE IN AccCORDANCE WiTH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 130 FEET OF 2 INCH POLY MAIN AND RETIRE 130 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 1 SERVlci:; IN ACCORDANCE WITH RAILROAD COMMISS[ON OF TEXAS RULC8.209
WTX Retirements Page7 of11
CUSTOMERS BENEFITED LOCATION PURPOSE OF PROJECT
ALL-MIX 03-0 TEXAS DIVISION SYSTEM tNTEGRHY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION PUBLIC IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITI'
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL·MIX 030 TEXAS DMSION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 03-0 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRrn'
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISlON SYSTEM INTEGRJTY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRl1Y
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MtX 030 TEXAS DIVISION SYSTEM INTEGRlTY
All· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SVSTEM INTE;GRITY
ALL- MIX 030 TEXAS DIVtSIDN SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION PUBLIC IMPROVEMENTS
All- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All· MIX 030 TEXAS DIVISION SYSTEM INTE;GRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 03-0 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX oao TEMS DlVJSION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MlX 030 TEXAS DIVISION SYSTEM INTEGRITY
LINE NO. PROJECT NUMBER COST(11
263 030.39772 (371)
264 030.39800 (521)
265 030.39801 (755)
26$ 030.39805 (9~
257 03-0.39811 (91)
268 030.39819 (78)
259 030.39846 (136f
270 030.39881 (175)
271 030.39862 (163)
272 030.39897 (22,248)
273 030.39917 (586)
274 030.39918 [99)
275 030.39949 {1.048)
276 030.39976 (13,419)
277 030.39985 j7,474)
278 030.39988 (4,099)
279 030.39990 (914)
280 030.40003 (473)
281 030.40011 (21,491)
282 030.40018 {1,065)
283 030.40019 (35,658)
284 030.40037 (2.759)
285 030.40062 (510)
289 030.40097 (2,076)
287 030.40104 137)
288 030.40106 (216)
289 030.40107 1134)
290 030.40114 !387)
291 030.40116 (859)
292 030.40124 (12)
293 030.40137 !12,230)
294 030.40141 (6)
295 030.40142 !43,700)
296 030.40146 j176)
'l!J7 030.40148 196)
21l8 030.40159 (1,101)
2S9 030.40164 (394)
300 030.40165 (6)
301 030.40166 (43)
302 030.40170 (28)
303 030.40171 (62)
304 030.40172 (254)
ALLOCATED COST
(371)
(521)
1755)
ArMos ENERGY CORPORATION, WESTTEXM mVIS.ION INTERIM co.sr .RECOVER'( AND JtATE ADJUSTMENT REPORT
PROJECT REPORT C'i 2016
DESCRIPTlON OF COMPl-ETED PROJECTS DEDICATED TO PUBUC USE IN CALENDAR YEAR2016 (21
INSTALL 253 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 263 FEET OF 2 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH RAlU;:oAD COMMISSION OF TEXAS RULE 8.20:9 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMlSSION OF I~ RUL~ B.209 INSTALL 5 FEET OF 6 INCH STEEL MAIN AND RETIRE 1 6 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
(9) 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
j91) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUIUD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
j78) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST All 104 FEET OF 4 INCH POLY MAIN AND 1 SERVICE AND RETIRE 104 FEET Of 3 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE WITH
(136) RAILROAD COMMISSION OF TEXAS RULE 8.21l9 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
(175) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE; TO SYSTEM IMPROVEMENT IN
(163) ACCORDANCE Wini RAILROAD COMMISSION OF TEXAS RULE 8.21l9 RETl:RE 11, 199 FEET OF 2 INCH PVC MAIN IN ACCORDANCE WITH RAILROAD
j22,248) COMMISSION OF TEXAS RULE 8.21l9 INSTALI. 400 FEET OF 2 INCfl POLY MAIN ANO 12 SERVICES AND RETIRE 400 FEET OF> INCH STEEL MAIN AND 12 SERVICES IN ACCORDANCE WITH
(586) RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 130 FEET OF 6 INCH POLY MAIN IN ACCORDANCE wm; RAILROAD
(99) COMMISSION Of TEXAS RULE 8.209
INSTALL 635 FEET OF 2 INCH POLY MAIN AND RETIRE 535 FEET OF 2 INCH ABS (1,048) MAIN IN ACCORDANCE Wffi-1 RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 3143 FEET OF 2 !NCH POLY MAIN AND 122 SERVICES AND RETIRE 3143 FEET OF 2 INCH STEEL MAIN AND 122 SERVICES IN ACCORDANCE WITH
(13,419) RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 8016 FEET Of 2 AND 4 INCH POLY PIPE; TO REPLACE 2 ANO 3 INCH STEEL PIPE AND 114 SERVICES IN ACCORDANCE WITH RAILROAD
(7.474l COMMISSION OF TEXAS RULE; 8.209 INST ALL 1794 FEET OF 4 INCH POLY MAIN AND 6500 FEET OF 2 INCH POLY MAIN AND 120 SERVICES AND RETiRE 4749 FEET OF 2 INCH STEEL MAIN AND ASSOCIATED SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF
(4,099) TEXAS RULE 8.209 INSTALL853 FEET DF2 INCH POLY MAIN AND RETIRE 853 FEETDF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
1914} 8.209 INSTALL257 FEETOF2 INCH POLY MAIN AND RETIRE 257 FEET OF INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
(473) 8.21l9 INST ALL 8302 FEET OF 2 INCH POLY MAIN AND 66 SERVtCES AND RETIRE 8'302 FEET OF 3 INCH STEEL MAIN AND 66 SERVICES IN ACCORDANC:E WITH
(21.491) RAil.ROAD COMMISSION Of TEXAS RULE 8.209 INSTALL 752 FEET OF 2 INCH POl-Y MAIN AND 2 SERVICES AND RETIRE 433 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH
(1,005} RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 3319 FEET 6 INCH, 8322 FEET 4 INCH, 3543 FEET 3 INCH, AND 2550 FEET2 INCH STEEL WITH 12,63<1 FEET2 INCH, 10<10 FEET 4 INCH POLY AND 177 SERVICES DUE TD SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD
(35,6581 COMMISSION OF TEXAS RULE 8.209 RETlRE 444 FEET OF 8 INCH STEEL M~N IN ACCORDANCE WlTH RAILROAD
(2.7561 COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
(510) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 154 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WlTH RAILROAD
(2.076) COMMISSlON OF TEXAS RULE 6.209 RETIRE REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
(37) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTAE.L 350 FEET OF 2 INCH POLY MAIN AND 7 SE;RVICES ANO RETIRE 350 FEET IF 2 INCH STEEL MAIN AND 7 SERVICES IN ACCORDANCE WITH
(218) RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 250 FEET OF 1.25 INCH POLY MAIN AND 5 SERVICES AND RET!RE 250 FEET OF 2 INCH STEEL MAIN AND 5 SERVICES IN ACCORDANCE WITH
(134) RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 322 FEET OF 2 INCH POLY IP TO CONNECT SYSTEMS AND REMOVE RS6146 DUE TO SYSTEM IMPROVEMENT IN ACCOR!lANCE WITH RAILROAD
1387) COMMISSION OF TEXAS RULE 8.209 RETIRE 766 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
(859) COMMISSION Of TEXAS RULE 8.:209 INSTALL 10 FEET OF 3 INCH STEEL MAIN AND RETIRE 1 3 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE
(12) 8.209 ABANDON 10010 FEET OF 21NCH STEEL. INSTALL7536 FEET OF2 INCH POLY, 758 FEET OF 4 INCH POLY AND 125 FEET OF 6 INCH POLY. REPLACE 46 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
(12,230) 8.209"
REBUILD REGULATOR STATtON DUE TO SYSTEM IMPROVEMENT IN i6J ACCORDANCE WITH RAILROAD COMMISStON OF TEXAS RULE 8.209-
RETIRE 17,665 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD (43,700) COMMISSION OF TEXAS RULE 8.208
INSTALL 75 FEET OF 2 INCH POLY MAIN AND 2 SERVlCES AND RETIRE 75 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD
(176) COMMISSION OF TEXAS RULE 8.209 INSTALL 36FEET OF 2 INCH l'DLY MAIN AND 2 SERVICES AND RETIRE 38 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD
(96) COMMISSION OF TEXAS RULE 6.209 RETIRE 1736 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAO
{1,101) COMMISSION OF TEXAS RULE 8.209 INSTALL 380 FEET OF 2 INCH POLY MAIN ANO RETIRE 380 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
1394) a.200 INSTALL 20 FEET DF 2 INCH STEEL MAIN AND RETIRE 20 FEET OF 2 INCH STEEL MAIN AND 1 2 INCH DRESSER COUPLING IN ACCORDANCE WITH
(B) RAILROAD COMMISSION OF TEXAS RULE 6.209
(43)
(2B)
(62)
(254)
INST ALL 11 FEET OF 6 lNCH STEEL MAIN AND RETIRE 11 FEET OF 6 INCH STEEL MMN AND 1 8 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 RETIRE 2-2 INCH DRESSER COUPLINGS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209
INSTALL 40 FE;ET OF 2 INCfl POLY MAlN AND RETIRE 40 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 20 FEET OF 4 INCH STEEL MAIN AND RETIRE 20 FEET OF 4 INCH STEEL AND ONE 4 INCH DRESSER COUPLING IN ACCORDANCE Willi RAILROAD COMMISSION OF TEXAS RULE 8.209
wrx Retirements Page Sof11
CUSTOMll:l=i:S BENEFITED LOCATION PURPOSE OF PROJECT
All-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL· MIX 030TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DNISION SYSTEM INTEGRITY
ALL-MIX 030TEXAS DIVISION SYSTEM IMPROVEMENTS
ALt.-MIX oao TEXAS DNISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DMSION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVlSION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DMSlON SYSTEM INTEGRITY
ALL- MIX 030 lEXAS DIVISION SYSTEM INTEGRln'
ALL- MIX 0:30 TEXAS DEV!S!ON PU!!LIC IMPROVEMENTS
Al..L-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRJTY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM !NTEGRl1Y
ALL·MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 03-0 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 03-0 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM IMFHO'lf:MENTS
ALL-MIX 030 TEXAS DiVISIDN SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DllMIDN SYSTEM INTEGRITY
ALL-MIX 030TEXAS DIVISION SYSTEM INTEGRITY
All- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
Al..L·MIX 030 TEXAS !JIVISEON SYSTEM INTEGRITY
Al..L-MIX 030 TEXAS DIVISlDN SYSTEM lNTEGRITY
ALL-M!X 030 TEXAS DMSION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
LINE NO. PROJECT NUMBER cOST(1)
305 030.40181 (192)
306 030.40251 1411)
307 030.40283 (1.416)
308 030.40305 12)
309 030.40338 (255)
310 030.403:56 (2.638)
311 030.40364 (678)
312 030-40367 (52)
313 030.40375 (2)
314 030.40379 (11)
315 030.40390 1101
316 030.40391 (3)
317 030.40392 (6)
318 030.40433 123)
319 030.40440 (13)
320 030.40446 (1,4811
321 030.40450 (4,031)
3>2 030-40456 (143)
3>3 030.40482 11,811)
324 030.40400 (7,7311
325 030.40532 (90)
326 030.40551 (1,BBB)
327 030.40558 (838]
328 030.40609 (79)
329 030.40610 (735)
330 030.40618 (8,896)
331 030.40619 (11,719)
332 030.40020 (1,753)
333 030,40679 (21)
334 030.40724 (18,676)
33.'l 030.40750 (5,275)
336 030.40752 (168)
667 0'30.40756 (6,726)
338 030.40757 (543)
339 030.40789 (313)
340 030.40803 (18,955)
341 030.40637 (448)
342 060.40839 (301)
343 030.40852 (15.119)
344 030.40853 (9,961)
345 030.40859 (8)
346 030.40860 (11)
ALLOCATED COST
(192)
(411)
(1,416)
ATMOS ENE:;RGY CORPORATION, WEST TEXAS OIVIS10N fNTERIM COST RECOVERY AND RA'rEADJIJS'l'MENT REPORT
PROJECT REPORT C.Y 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR VEAR2016 (01
INSTALL 300 ftEET OF 1.25 INCH POLY MAIN AND 1 SERVICE AND RETIRE 300 FEET OF 2. INCH STEEL MAIN AND 1 SERVICE lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209 INSTALL 282 FEET OF 2 INCH POLY MAIN ANO 3 SERVICES AND RETIRE 282 FEET OF 2 INCH STEEL MAIN AND 3 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 385 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RUUE 8,209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
(2) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 90 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 90 FEET Of 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD
(255) COMMISSION OF TEXAS RULE 8.209 REPLACE REGULATOR STATION IN ACCORDANCE WITH RAILROAD
(2,638) COMMISSION OF TEXAS RULE 8.209
PERMIAN BASIN AREA OPERATIONS BLANKET TO COVER REPLACE/RETIRE T AsKS: CP SHORT SECTIONS AND BREACHED CP SHORTED SECTIONS IN
(67Bf ACCORDANCE Wf!H RAILROAD COMMISSION OF TEXAS RULE 8.209 PAMPA OPERATIONS BLANKET TO COVER REPLACE/RETIRE TASKS: CP SHORT SECTIONS AND BREACHED OP SHORTED SECTIONS IN ACCORDANCE
(52) WITH RAILROAD COMMISSION Of TEXAS RULE B.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
!21 ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DllE TO SYSTEM IMPROVEMENT IN
(11) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
(10) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
(3) ACCORDANCE WITH RAJLROAD COMMISSION OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
(6) ACCORDANCE WITH RAILROAD COMMISStON OF TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
~23) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT JN
(13) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS: RULE B.200 fNSTALL 1 B47 .FEET OF 2 INCH POLY MAIN AND 7 SERVIGES AND RETIRE 1880 FEET OF 2 INCH STEEL MAIN ANO 7 SERVICES IN ACCORDANCE WITH
11.481) RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 580 FEET OF 2 INCH PO" Y MAIN DUE TO SYSTEM INTEGRITY IN
(4.061) ACCORDANCE WITH RAILROAO COMMISSION Of TEXAS RULE 8.209 REBUILD REGULATOR STATION DUE TO SYSTEM IMPROVEMENT IN
(143) ACCORDANCE WITH RAILROAD COMMlSSION OF TEXAS RULE B.209 INSTALL 265 FEET OF 2 INCH POLY MAIN AND 3 SERVICES AND RETIRE 265 FEET OF 2 INCH POLY MAJN AND 3 SERVICES IN ACCORDANCE WITH
(1,811) RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 190 FEET OF 2 INC>l POLY MAIN AND RETIRE 190 FEET OF 2 INCH STEE;L MAIN AND 2 SERVICIOS IN ACCORDANCE WITH RAILROAD COMMISSION
(7.731) OF TEXAS RULE; 8.209 REPLACE 90 FEET OF 2 INCH STEEL WITH 2 lNCH POLY IN ACCORDANCE WITH
190) RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 230 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 230 FEET OF 2 INCH STEEL MAIN AND 2 SERVICES IN ACCORDANCE WITH
(1,688) RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 657 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD
{838) COMMISSION OF TEXAS RULE 8.209 INSTALL 65 FEET OF 2 INCH POLY MAIN AND RETIRE 65 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
(79) a.209 INSTALL 750FEET Of 2 INCH POLY MAlNAND 11 SERVICES AND RETIRE 1050 FEET OF 2 INCH STEEL MAlN AND 11 SERVICES IN ACCORDANCE WITH
(735) RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 5 FEET OF 3 INCH STEEL MAIN AND RETIRE 5 FEET OF 3 INCH STEEL MAIN AND ONE 3 INCH DRESSER COUPLING IN ACCORDANCE WITH RAtLROAD
(8,896) COMMISSION OF TEXAS RULE 8.209 INSTALl 7 FEET OF 3 INCH STEEL MAJN AND 2 SERVICES AND REMOVE 1 FEET OF 3 INGH STEEL MAIN AND ONE 3 INCH DRESSER COUPLING IN
(11,719) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.2.09
INSTALL 20 FEET OF 4 INCH POLY MAIN AND RETIRE 20 FEET OF 2 INCH POLY (1.753) MAJN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
RETIRE 670 FEET OF 3 INCH STEEL MAIN AND 1 SERVICE IN ACCORDANCE (211 WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 2361 FEET OF 4 INCH POLY MAIN ANO RETIRE 2331 OF 3 INCH STEEL (18,675) MAJN IN ACCORDANCE WITH RAILROAD COMMISSION OF Tl'XAS RULE 8_209
RETIRE 3052 FEET OF 2 !NCH STEEL MAIN IN ACCORDANCE WITH RAILROAD (5,275) COMMISSION OF TEXAS RUUE 8_209
INSTALL 15 FEETOF4 INCH POLY MAIN AND RETIRE 15 FEET OF.ii INCH STEEL (168) MAIN IN ACCORDANCE wrn; RAILROAD COMMISSION OF TEXAS RULE 8.209
ABANDON 395 FEET OF 1 INCH STEEL. 886 FEET OF 1.25 INCH STEEL AND 4551 FEET OF 2 INCH STEEL AND INSTALL 5820 FEET OF 2 INCH POLY AND REPLACE 24 SERVICES IN ACCORDANCE WITfl RAILROAD COMMISSION OF
(6,723) TEXAS RULE 8.209 REPLACE 348 FEET 3 INC!l AND 240 FEET 2 INCH STEEL WITH 372 FEET 4 INCH AND 305 FEET 2 INCH POLY DUE TO SYSTEM lr.TEGRITY IN ACCORDANCE
(543) Wlll-i RAILROAD COMMISSION OF TEXAS RULE 8.200 INST ALL 550 FEET OF 2 INCH POLY MAIN AND 4 SERVICES AND RETIRE 550 fEET OF 2 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH
(313) RAILROAD COMMISSION OF TEXAS RULE 8.209 INST ALL 8634 FEET OF 2 INCH POLY .216 PIPE WITH 54 SERVICES IN
(18,955) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.2'J9 REPLACE 1727 FEET OF 2 INCH POLY DUE TO SYSTEM INTEGRITY IN
(446) ACCORDANCE WITH RAILROAD COMMISSION Of TEXAS RULE 8.209 INSTALL269 FEET OF2 INCH POLY MAIN AND RETIRE269 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF Tl'XAS RULE
(301) 8.209 INST ALL 1500 FEET OF 2 INCH POLY MAIN AND 14 SERVICES AND RETIRE 1500 FEET OF 2 !NCH PVC MAIN AND 14 SERVICES !N ACCORDANCE WITH
115,119} RAILROAD COMMISSION OF TEXAS RULE 8.209 REl'LACE3773 FT OF3 INCHSTEEl AND 2365 FEET OF2 INCH STEEL MAIN WITH 3800 FEET OF 4 INCH POLY AND 2145 FEET OF 2 INCH POLY IN
(9,001) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE AND LOWER 3990 FEET OF 3 INCH STEEL MAIN WITH 4 IN POLY MAIN DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION
(8) OF TEXAS RULE a,009
!111
INSTALL 100 FEET OF 2 INCH POLY MAlN AND 2 SERVICES AND RETIRE 300 FEET OF 2 INCH STEEL MAIN AND '2 SERVICES DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WffH RAILROAD COMMISSION OF TEXAS RULE 6.209
WTX Retir-l!!m~nts Page9of11
CUSTOMERS aENEFITED LOCATION PURPOSE OF PROJECT
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS Drv!SION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
Al.L-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM iMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 03-0 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DJVISION SYSTEM lMPRDVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 Tl'XAS DIVISION SYSTEM INTEGRITY
ALL·MIX 030 TEXAS DIVISION SY.STEM INTEGRITI'
/\LL-MIX 000 Tl'XAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DMSION SYSTEM JNTEGRln'
ALL-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
ALL-MiX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 0:30 TEXAS DMSION SYSTEM INTEGRITY
ALL-MIX 0'30 TEXAS DMSION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DMSION SYSTEM IMPROVEMENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DlVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAs DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION PUBLIC lMPROVE;MENTS
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION PUBLIC IMPROVEMENTS
LINENO, PROJECT NUMBER COST(1)
347 030.401162 (1.685)
348 030-40864 (560)
349 030.40866 (57)
350 030.40673 ($72)
351 030.40931 [12,230}
352 030.40965 [24)
353 030.40969 (236)
354 030.40978 [6,447)
355 030.40979 (558)
35S 030.40980 (207)
•57 030.40904 (372)
35<1 030.40985 {20)
••• OOC.40987 (12,156)
360 030.40990 (15,249)
361 030,409.92 (29)
362 030.40998 (2,086)
'!63 030.41010 (137)
'!64 030,41022 (2)
365 030.41023 {162)
306 030.41024 (1.115)
387 030.41052 (3.235)
368 030.41065 {207)
369 03M1066 (3,344)
370 030.41072 {3,303)
371 030.41073 [1,115)
372 030.41089 (17)
373 OJ0.41185 (10,56J)
374 030.41186 [6)
375 030.41189 (231
376 030.41191 (25)
377 030.41199 (176)
378 030.41202 (1,042.)
379 030.41260 [2,312}
380 030.41334 (18,3611
3S1 030-41336 (11,8141
3S2 030.41"44 (4,457)
363 030.41360 [1,8131
384 030.41376 (1,975)
305 030.41377 (156~
386 030.41379 (984)
387 030.41412 (96)
ALLOCATED COST
(1,685)
(560)
{57)
[672)
[12,230)
!24)
[236)
(6.447)
(558)
(207)
(372)
(20}
(12,156}
(15,249)
(29)
[2,0861
(137f
ATMOS ENERGY CORPORATION, WE:S.TTEX.A.$ OM:SlON INlE~IM COST f\ECO\/EFIV AND RATE ADJUSTMENT R£PORT
PROJECT REPORT CY 2016
DESCR!PTtON OF COMPLETED P:ROJE.CTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2)
INST ALL 581 FEET OF 2 INCH POLY MAIN AND 4 SERVICES AN!J RETIRE 1102 FEET OF 4 INCH STEEL MAIN AND 4 SERVICES IN ACCORDANCE WITH RMLROAD COMMISSION OF TEXAS RULE 8.20.9
INSTALL 319 FEET OF 2 INCH POLY MAIN AND 9 SERVICES AND RE.TIRE 360 FEET OF 4 INCH STEEL MAIN AND 9 SERVICES DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH .RAILROAD COMMISSION Of TEXAS RULE 6.209 INSTALL 7S FEET OF 2 INCH STEEL MAIN AND RETIRE 68 FEET OF 2 INCH STEEL MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.200 RETIRE 230 FEET OF 6 INCH STEEL lN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.:209 INSTALL 245 FEET OF 2 INCH POLY MAIN AND RETIRE 271 FEET OF 2 INCH POLY MAIN !N ACCORDANCE WITH RAlLROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 25 FEET OF 3 INCH POLY MAIN AND RETIRE 25 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 5 FEET OF 2 INCH POLY MAIN DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 6 FEET IF 4 INCH STEEL MAIN AND RETIRE 6 FEET OF 4 INCH STEEL MAIN AND ONE 4 INCH DRESSER COUPUNG IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE ONE 3 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 225 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE ONE 2 INCH DRESSER COUPLING IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE DRESSER DUE TO SYSTEM INTEGRITY IN ACCORDANCI' WITH RAILROAD COMMlSSION OF TEXAS RULE 6.209 INSTAll 2539 FEEf OF 6 INCH POLY MAIN AND 15 SERVICES AND RETIRE 2539 FEET OF 6 INCH STEEL MAIN AND 15 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 1149 FEET OF 4 INCH POLY MA!N AND RETIRE 1000 FEET OF 6 INOH STEEL MAIN IN l\OCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 RETIRE ONE 2 lNCH STEEL VAf...VE. IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6.209 INSTALL 170 FEET OF 2 INCH POLY MAfN ANO RETIRE 170 FEET OF 2 INCH POLY MAlN IN ACCORDANCE WITH RAILRDAD COMMISSION OF TEXAS RULE 8.209
INSTALL41 FEET OF2 INCH POLY MAIN AND RETIRE25 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL ONE 6 INCH WELOOVER IN ACCORDANCE WJTH RAILROAD
{2f COMMISSION OF TEXAS RULE 8.209 INSTALI. 1 SERVICE AND RETIRE 65 FEET OF 2 INCH STEEL MAIN IN
(162) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL543 FEET OF 2 INCH POLY MAIN AND RETIRE 543 FEET OF 2 INCH PVC [1.115) MAIN IN ACCORDANCE WITH RAii.ROAD COMMISSION OF TIOXAS RULE 8.209
REPLACE 160 FEET OF 2 INCH POLY, 1588 FEETOF2 INCH STEEL, 405 FEET OF 3 INCH STEEL AND 1131 FEET OF 6 INCH STEEL WITH 770 FEET OF 2 INCH POLY AND 1748 FT OF 4 INCH POLY WITH 7 SERVICES IN ACCORDANCE WITH
{3,235) RAILROAD COMMISSiON OF TEXAS RULE B.209
INSTALL 96 FEET OF 6 INCH POLY MAIN /\ND RETIRE 88 FEET OF 8 INCH STEEL (207) MAIN IN ACCORDANCE WITfl RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 1 SERVICE ANDRET!R;E: 115 FEETOF2 ~NCH STEEL MAIN IN (3,344) ACCORDANCE W!TH RAILROAD COMMISSION OF 1EXAS RULE; 6.209
INSTALL 4253 FEET OF POLY TO REPLACE STEEL AND Im SERVICES IN (3,303) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INSTALL 866 FEET OF 2 INCH POLY MAIN AND 16 SERVICES AND RETIRE 900 FEET OF 4 INCH STEEL MAIN AND 16 SERVICES IN ACCORDANCE WITH
{1.115) RAILROAD COMMISSION OF TEXAS RULE B.209 INST ALL 250 FEET OF 2 INCH POLY MAIN AND RETIRE 250 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
{17) 8.209 RETIRE 1458 FEET OF 2 INCH PVC MAIN IN l\CCORDl\NCE WITH RAILROAD
(10,563) COMMISSION OF TEXAS RULE B.209 RETIRE ORESSER DUE TD SYSTEM INTEGRITY IN ACCORDANCE WITH
(6) RAILROAO COMMISSION OF TEXAS RULE 8.200
{23)
(25)
(176)
i1,042)
(2,312)
[18,361)
(11,814)
(4,457)
(1,813)
(1.975)
[158)
(984)
{96)
~NSTALL 6 FEET OF 2 INCH STEEL MAIN AND 3 FEET OF 3 INCH STEEL MAIN AND RETIRE 9 FEET OF 2 INCH STEEL MMN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RVLE B.2.09 INSTALL 25 FEET OF 4 INCH STEEL MAIN AND RETIRE25 FEET OF4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 tNST ALL 382 FEET OF 1.25 INCH POLY MAIN AND RETIRE 382 FEET Of 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 6,209 INST ALL 148 FEET OF 6 INCH POLY MAIN AND 2 SERVICES AND RETIRE 100 FEET OF 8 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 620 FEET OF 4 INCH POLY MAIN /\ND RETIRE 620 FEET OF 4 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 7713 FEET OF 2!N. 41N, 61N, BIN STEEL AND PE AND 39 SERVICE:.S WITH 6305 FEET 2 INCH POLY DUE TO SYSTEM INTEGRITY IN ACCORDANC!:: WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE 7420FEET OF STEEL WllH a800FEET OF POLY, 100 SERVJCES, RETIRE 3 REG STATIONS AND REPLACE ONE REG STATION DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUlE 8.209 tNST ALL 301 FEET OF 2 INCH POLY MAIN AND RETIRE 400 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REBUILD METER SETTING DUE TO SYSTEM IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
INST ALL 28 FEET OF 2 INCH POLY MAIN ANO RETIRE 26 FEET DF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RETIRE 195 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTALL 585 FEET OF 2 INCH POLY MAIN AND 3 SERVICES AND RETIRE 573 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL 841 FEET OF 2 INCH POLY MAIN AND 22 SERVICES /\ND RETIRE a41 F~ET OF 1 INCH STEEL MAIN AND 22 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE a.209
WIX Retirements Page 10of11
CUSTOMERS BENEFITED LOCATION !>URPOS~ OF PROJECT
ALL- MIX 030 TEXAS DIVISION PUBLIC IMPROVEMENTS
ALL·MIX 030 TEXAS DIVISION PUBLIC IMPROVEMENTS
l\LI.-MIX 030 TEXAS DJVISION PUBLIC IMPROVEMENTS
/\LI.-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL·MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
/\LL-MIX 030 TEXAS DJVISION SYSTEM INTEGRITY
/\LL-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
All-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 1EXAS DMSlON SYSTEM INTEGRITY
ALL· MIX OJO TEXAS D!V!SlON SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX 030 lEXAS DIVISION SYSTEM INTEGRITY
ALI.-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALI.-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYST:EM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRl1Y
/\LL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
/\LL.MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
/\LL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION PUBLIC IMPROVEMENTS
ALL-MIX 030 TEXAS DIVJSION SYSTEM INTEGRITY
/\LL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
All-MIX 030 TEXAS DMSION SYSTEM INTEGRITY
/\LL-MIX OJO TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL· MIX OJO TEXAS DIVISION SYSTEM INTEGRlTY
/\LL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
/\LL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL- MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL·MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
/\LL-MIX 030 TEXAS DIVISION SYSTEM IMPROVEMIO~'TS
ALL-MIX 030 TEXAS DIVJSIDN SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALL-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
ALI.-MIX 030 TEXAS DIVISION SYSTEM INTEGRITY
LINENO.
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402 403
404 405
406
~ ~ ~ ~ __ 4_11_
PROJECT NUMBER COST(1)
OJ0-41424 (J)
030.41438 (15)
030.41470 (2621
030.41487 (70.360)
030.41557 (67)
030.41576 (5221
030-41595 (96}
030.41675 {7.492)
030.41711 (401)
030.41861 (2,090)
030.4186'3 {4.469)
030.41898 (2,707)
030.42034 (455)
030.42036 (42<1)
TOTAL TEXAS RULE B,209 PROJECTS (LN.119-LN.401) 14,320,3941
TOTAL ALL WEST TEXAS RETIREMENTS (LN. 2 + LN.115+ LN.
402) /12,240,879
TOTAL CHANGE IN WEST TEXAS PLANT
PER BOOK (LN. 404 + WTX
ADDITIONS LN. 3634) 68,469,196
NOTES:
ALLOCATED COST
ATMOS ENERGY CORPORA.TION, WEST TEXAS DIVISION INTERIM COST R!COVERY ANO AATE AOJUSTM!NT R!PORT
PROJECT REPORT C'/ 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUB UC USE IN CALENDAR YEAR 2016 (2)
INSTALL 5 FEET Of 2 INCH STEEL PIPE AND REMOVE DRESSER DUE TO SYSTEM INTEGRllY IN ACCORDANCE WrTH RAILROAD COMMISSION OF TEXAS
(3) RULE B.209 REPLACE 20 FEET OF STEEL WITH POLY DUE TO SYSTEM INlEGRl1Y IN
{15) ACCOROANCEWHH RAILROAD COMMISSION OF TEXAS RULE B.209 INSTALL372 FEET OF 2 INCH POLY MAIN AND RETIRE 372 FEET OF2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
(262) 8.209 RETIRE 16,484 FE:ET OF 4 [NCH STEEL DUE TO SYSTEM [NTEGRITY IN
{70,360) ACCORDANCE WITH RAILROAD COMMISS(ON OF TEXAS RULE 8.209 INSTALL 456 FEET OF 2 INCH POLY MAIN AND 1 SERVICE AND RETIRE 564 FEET OF 1 INCH STEEL MAIN ANO 1 SERVICE IN ACCORDANCE WllH
(87) RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE 143 FEET OF 2 INCH AND 1497 FEET OF 3 INCH STEEL WITH 172 FEEf O~ 2 INCH AND 157.9 FEET OF 4 INCH POLY AND REPLACE 13 SER~CES DUE TO SYSTEM lNTEGRllY !N ACCORDANCE WllH RAILROAD COMMISSION
(522) OF TEXAS RULE B.209 REPLACE AND LOWER 2 INCH STEEL MAIN ACROSS HWV 54 AT BLAIR STREET DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD
(96) COMMISSION OF TEXAS RULE B.209 REPLACE AND LOWER 125 FEET B INCH PE WITH 175 FEET6 INCH POLY DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF
(7,492) TEXAS RULE B.200 REPLACE 1/l60 FEET OF 3 INCH AND 41N UNPROTECTED STEEL AND 19 SERVICES WITH 1750 FEET21NCH POLY DUE TO SYSTEM INTEGRllY IN
(401) ACCORDANCE WllH RAILROAD COMMISSION OF TEXAS RULE 8.209 RELOCATE 235 FEET OF 2 INCH POLY WITH 231 FEET OF POLY AND ONE SERVICE DUE TO CUSTOMER REQUEST IN ACCORDANCE WITH RAILROAD
(2,000) COMMISSION OF TEXAS RULE 8.209
REPLACE 584 FEET OF 3 INCH STEEL ANO 1436 FEET OF 2 INCH STEEL AND 30BFEET Df 2 INCH POLYWllH 578 FEET Of 4 INCH POLY AND 1266 FEET OF 2 INCH POLY AND REPLACE SB SERVICES DUE TO SYSTEM INTEGRllY IN
(4.469) ACCORDANCE WITll RAILRDAD COMMISSION OF TEXAS RULE a.209 REPLACE 1305 FEET Of 2 INCH STEEL ANO 121 FEET OF 2 INCH POLY WITH 1676 FEET OF 2 INCH STEEL AND REPLACE 12 SERVICES DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
(2,707) 8.209 ABANDON 35'1 FEET OF 3 INCH STEEL DUE TO SYSTEM INTEGRITY IN
(455) ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 INSTAU. 600 FEET DF 2 INCH POLY AND 4 SERVICES DUE TO SYSTEM INTEGRllY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE
(424) 8.209
(4,320,394)
(12,230,069)
68,377,482
{1} The "COST' column reftecra the <:apitalEzed portion of the oost only.
CUSTOMERS .BEl'llEFtfED
ALL-MIX
ALL·MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL·MIX
ALL-MIX
AL!.-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
(2) The "DE;SCRIP'TION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE lN CALENDAR YEAR 2016" column describes c:apltallzed costs only.
WTX Retirements Pagl!!11of11
LOCATION PURPOSE OF PROJECT
030 TEXAS DIVISION SYSTE;M INTEGRllY
030 TEXAS DIVISlON SYSTEM INTEGRllY
030 TEXAS DIVISION SYSTEM INTEGRllY
030 TEXAS DIVISION SYSTEM INTEGRllY
030 TEXAS DIVISION SYSTEM INTEGRITY
030 TEXAS DIVISION SYSTEM INTEGRITY
030 TEXAS DIVISION PUBLIC IMPROVEMENTS
030 TEXAS DIVISION PUBLIC IMPROVEMENTS
030 TEXAS DMSION SYSTEM INTEGRllY
OJO TEXAS DIVISION SYSTEM INTEGRITY
030 TEXAS DIVISION SYSTEM INTEGRllY
030 TEXAS O!VISION SYSTEM INTEGRllY
030 TEXAS DIVISION SYSTEM INTEGRllY
0:30 TEXAS OMS!ON SYSTEM INTEGRITY
ALLOCATION LINENO. PROJECT.NO. COSTl1' TOWTX
SSU ADDITIONS. Gl£Hf!RAL OFFICE PER BOOK® 7.38%
1 010.1128< t8607l l«W
2 010.11395 14,1'601 1"66
3 010.11473 14,660] 1344
• 010.21.(927 1.009,352 7fl.65Q.
5 010.2184• 30S 23
6 010.24225 238,499 17591
7 010_24234 1 0
B 010.24367 279 21
• 010.24960 -674 7.56 ~9767
10 010.25337 2 526,747 1"6,363
11 010.25706 1 638 121
12 010.251'69 oM,760 28 37B
13 010.25987 B96 136
14 010.2.6124 721 63
15 010.26405 400,712 3324:3
16 010.26448 13'9 853 10,315
17 010.26455 613 514 45.251
1a 010.2645B !2SB1 r1•
19 010.26459 21114 158
20 010.26460 4,379 323
21 010.26484 254101 18.742
22 010.2Sfl3fl 695 51
23 010.26644 7,79B 575
24 010.26646 3;653 269
25 010.26682 504 37
26 010.26697 20,000 1475
27 010.26746 3:2,068 2,365
28 010.26749 ') 932 215
29 010.257.50 12,913 952
30 010.26751 31 089 2,293
31 010.26778" 28B 21
32 (110,26780 6,593 486
33 010.2.6786 2945 217
ATMOS EJi.li:~G'V' CORPORATION, SHARED S~RYICl:'.S
iNTERIM COST RECOVl5R'Y Aria RA.IE ADJUSTMENT REPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 {2]
l2, 1'6lH FLOOR TENANT IM?ROVEMENr ~~OM SIGNING NEW I.EASE.
WACO CONTACT CENTER OFFlCE CHAIR AND EQUIPMENT.
WACO CCC IMPROVEMENTS.
BUILD SHARED MOBILE APP FOR READ ONLY ACCESS TO SCADA DATA (ATLAS). WILL SUPPORT SHARED SERVtCES GAS CONHIOL, MID-TEX PRESSURE CONTROL, APT SCADAIRTU OPERATIONS. ATLAS FUNCTIONS INCLUDE: READ-ONLY ACCESS TO SCADA DATA. IN A LIST AND ON A MAP; STATUS INFORMATION, GREEN FOR NORMAL ANO RED WHEN SOMETHING NEEDS TO BE LOOKED AT; NEAR REAt.-TIME DATA. WITH AUTO REFRESH WHEN NEW DATA IS AVAILABLE; VISIBILITY TO CONTROL ROOM At.ARMS; THE: ABH.ITY TO SET THEIR OWN ALERT RULES AND MANAGE THEM: THE ABEUTY TO GROUP DATA BY DEVICE, SJTE OR REGION SO THEY CAN FOCUS ON WHAT IS IMPORTANT FOR lHE!R AREA; THE ABlllTY TO SEE: DATA lRENOS AND TO RUN REPORTS AND EXPORT THE DA.TA; ACCESS PR5SET DASHBOARDS ANO REl'i:>RTS THAT SUMMARIZE DATA FOR SPE;CIFIC USERS AND USES' AND THE ABILITY TO USE IT ON THEIR MOBJLE DEVICES AND WITH THEIR DESKTOP BROWSERS,
IMPLEMENT CV BER SAFETY SECURE. ACCESS FOR STORAGE AND COMPRESSION CONTROL SYSTEMS AND DEVICES.
NETWORK INFRASTRUCTURE IMPROVEMENTS· DNS APPLIANCE. REFRESH llNFBLOXl. IMPROVEMl::iNrS TO lHE aA l.Aa INCLUDING LICENSES FOR TEST TRACK AND ADDITIONAL HARDWARE AND SOFTWARE TO SUPPORT THE QA TESTING ENVIRONMENT.
PC REPLACEMENT PROJECT FOR FY 2015 FOR SHARED SERVICES.
ORACLE SINGLE SIGN-ON AND FDERATION IMPLEMENTATION. THE PROJECT WILL DEPLOY THE ORACLE ACCESS MANAGEMENT SUITE OF PRODUCTS TO PROVIDE SINGLE SIGN-ON ANO FEDERATION FUNCTIONAl.ITY TO THE INTERNAL ENVIRONMENT. PHASE 1 - INITIATIVE 1 - PROJECT DESIGN ESTIMATION ANO APPROVAL-A) ONE PROJECT DESIGN TOOL, B) COMMON ESTIMATION TEMPI.ATES ANO TOOL, C) IMPROVED INlERFACE FROM ESTIMATION TO APPROVAL, AND Dl ONE APPROVAL ?ROCESS.
APEX APP FOR EXTRACTING MARKVIEW IMAGES FOR RATE FILINGS.
PROCURE AND IMPLEMENT THE RSA SECURID SOLUTION FOR EXTERNAL AUTHENTICATION OF USERS TO OUR NETWORK.
HIGH DEOUCTASLE PLAN TRACKING APPUCATION fOR ENSURING HSA IS SElEClED.
SIJILO COR DERJVAT10N:S ro AUTOMATICALLY SPLIT COR AND INSTALLATION CHARGES IN POWERPLANT FOR MAINS & SERVICES.
IM:PERVA OAT ABASE FIREWALL- LICENSES AND PROFESSIONAL SERVICES.
ENHANCEMENT OF VARIOUS APPLICATIONS WITH THE GIS ENVIRONMENT.
ATMOSENERGY.COM RE\11/lllTE.
GVA EMC SOLUT!ON - D@RE SOLUTION, DD UPGRADE, DPS sum~; -80TB UPGRADE.
LC3 EMC SOLUTION- D@RE SOLUTION, DD UPGRADE, XIO UPGRADE, XIO PURCHASE.
GVA oMC EXTREMIO SOLUTION -XIO PURCHASE.
THE UPGRADE AND ENHANCEMENT OF AE TAX SYSTEM FOR COMPLIANCE.
t.2, 17TH FLOOR CONFERENCE ROOM AV UPDATES.
AODtrlONAL 1 IJOO AJRWATCH UCENsi:;s.
ONE LAPTOP COMPUTER WlTH ACCESSORIES.
L3, 5TH FLOOR CONFERENCE ROOM AV UPGRADES.
CKV AV UPGRADES.
CKV FURNllURE FOR TRA!NING.
ITS OPERATOR QUALIFICATION ANO DATA SERVICES INTEGRATION.
ENTERP'RlSE CROSS SORE APPLICATION DEVELOPMENT.
QAQC LEAK SURVEY APPUCATION.
ONE COMPUTER MONlTOR.
THREE LAPTOP COMPUlBRS
CKV r Wll roN VISE, 10116 800N MACHIN EST ~lEl3.1 Bt=.NCH VISE TO BE U:SE.C'J FOR CONSTRUCTION CLASSEl:$,
SSU AddJtf om;
Piil!ce lof5
CUSTOMERS BENEFITED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS- MIXED
ALL ATMOS CUSTOMERS~ MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
All ATMOS CUSTOMERS· MIXED
ALL ATMOS CUSTOMERS-MIXED
ALL ATMOS CUSTOMERS- MIXED
All ATMOS CUSTOMERS ·MIXED
All.ATMOS CUSTOMERS - MIXED
All ATMOS CUSTOMERS - MIXED
ALlATMOS CUSTOMERS r MJXED
ALL ATMOS CUSTOMERS -MIXED
ALL ATMOS CUSTOMERS - MJXED
ALL ATMOS CUSTOMERS ·MIXED
ALL ATMOS CUSTOMERS - MIXED
At.LATMOS CUSTOMERS r MIX.ED
ALL ATMOS CUSTOMERS ~MIXED
AU.ATMOS CUSTOMERS - MIXllD
Alt.ATMOS CUSTOMERS T MIXED
ALL ATMOS CUSTOMEERS - MIXED
All.ATMOS CUSTOMERS y MIXED
.ALL ATMOS CUSTOMERS - MIXoo
ALL ATMOS CUSTOMERS-MIXED
AU.ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS· MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS· MIXED
DATE PLACED l:NGASPLANT
LOCATION PURPOSE OF PROJECT IN SERVICE
SHAREO SERVICES STRUCTURES JANUARY
SHARED SERV!CES EQUIPMENT MARCH
SHARED SERVICES STRUC1URES JANUARY
SHARED SERVICES INFORMATION TECHNOLOGY .SEPTEMBER
SHARED SERVICES INFORMATEON TECHNOLOGY MARC!l
SHARED SERVICES lNFO:RMATION TECHNOLOGY DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY MARCH
SHA.i;!:EO SERVICES INFORMATION TECHNOLOGY MARCH
SHARED SERVICES INFORMATION TECHNOLOGY JUNE
SHARED SERVICES INFORMATION TECHNOLOGY OCTOBER
SHARED SERVICES INFORMATION TEDHNOLOGY OCTOBER
SHARED SERVICES INFORllll.ATION TECKNOLOGY DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY NOVEMBER
SHARED SERVICES INFORMATION TECHNOLOGY JUNE
SHARED SERVICES tNFORMATION TECHNOLOGY DECEMBER
SHARED SERV3CES INFORMATION lECHNOLOGY DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY DECoMBER
SHARED SERVlCES INFORMATION 1ECHNOLOGY JUNE
SHARED :SER~CES INFORMATION 1ECHNOLOGY JUNE
SHARED SERVICES INFORMATION TECHNOLOGY JUNE
SHARED S:ERVlCES INFORMA.TION TECHNOLOGY NOVEMBER
SHARED S:ERVlCES EQUIPMENT MARCH
SHARED SERVICES tNFORMATION 1ECHNOLOGY MARCH
SHARED SERVICES ~NFORMATION 1ECHNOLOGY JANUARY
SHAREO SERVICES EQUIPMENT MARCH
SHARED SERVICES EQUIPMENT MARCH
:SHARED SERVICES EQUIPMENT JUNE
SHARED SERVICES INFORMATION TECHNOt.OGY DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY OCTOBER
SHARED SoRVICES lNFORMATION TECHNOLOGY NOVEMBER
SHARED SERVICES EQUIPM5NT MARC!l
SHARED SERV!CES EQUIPMENT JUNE
SHARED SERVICES EQUIPMENT JANUARY
ALLOCATION LINE NO. .Jl'ROJl:::CTNO. COST111 TO WIX
34 010.28791 3,158 033
35 010.26816 958,648 70706
36 010.2:6821 10,207 75'1
37 010.:WB23 21.326 1.573
38 010.26824 9943 660
•• 010.2.6825 10,479 773
40 010.2sa26 7061 521
41 010.20•21 11 369 839
42 010.215836 7,109 524
•• :!J10.26B3B 6652 491
44 010.26839 4,831 356
45 010.26841 21,39'3 1,578
46 010.26845 1,523 112
47 010.26553 9.889 729
4B 010.26B77 1 071 629 79 039
49 010.2~04 18,514 1,366
50 010.26917 307695 22.694
51 010.26967 5204 384
52 010.27023 16.407 1,210
53 010.27105 1.900 HO
54 010.27131 2,367 175
6S 010.27133 20,649 1,503
56 010.27145 13.294 980
57 010.27152 Ei,SB3 486
58 010.27160 1,25'4 92
59 010.27178 18656 1 376
60 010.27215 0,522 461
61 010.27222 14654 1 0:81
62 010.27231 5.099 376
63 010.27253 i,763 130
64 010.27263- 4590 339
05 010.27311 5,744 424
66 010.27375 2,352 173
67 010.27379 1811 134
ea 010.27"140 12.41$ 910
69 010.27618 487,590 35963
70 orn.216118 13.016 960
AYMOS l:Nl:.RGY CORPORATION, SHARED S:ERVICE.S INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION Of COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR.2.016 [2.~
CKV - DEASON 2 JN -6 IN POLY PIPE PEELER USED FOR CONSTRUCTION CLASSES.
POWERTAX. REPAIRS/ IRS COMPLIANCE MODUlE TO THE POWERPl.AN SUITE.
REPLACING OLD IPADS FOR sTUD!iNTS usi; IN CLASSES.
CKV-VISUAL INTERACTIVE DRIVING SlMUlATOR IN CAB MODEL lX 38111 USED FOR CLASSES.
CKV ~SECOR FUSION UNtT AND 1WO INSERTS USED FOR CLASSES.
CKV - HEAL TH CONSULTANTS GMIJ-500 WATCHER FOR ClASSES.
11-iREE TIMSERLINE LONG HANDl.E POLY SQUEEZE TOOLS FOR ,ADVANCED SERV!CE CLASS .Sf4w2 IN.
FOOTAGE. LONG HANDLE STEEL SQUEEZE. TOOL.
CKV ~CENTRAL PROCESSOR MSA 340 (2} TO BE USE.D FOR CL.ASSES.
CKV - MT DEASON AUTOF!JSE PROCESOOR TRIPAF000001 (2) 2.800 TO So USED FOR CLASSES.
CKV - R.YCOM PIPE AND CABLE. lOCA TOR .ea69V9(2) TO ai:;.: USS:D FOR CLASSES.
MOBILEYE UNITS ~NSTAlLEO ON VEHICLES TO ENSURE SAFE DRIVING lECHNIQUES.
CKV - PUCHASE OPERATIONS AUDIO VISUAL EOUIPMENT.
ONE LAPTOP AND ONE DESKTOP COMPUTER.
THIS PROJECT WILL UPGRADE PGAS TO THE lATEST VERSION, WHICHIS16.
IMPLEMENTATION OF 01 AUTOMATED RATES FILLNG_
INFRASTRUCTURE UPGRADE ANO APPLICATION ENHANCEMENTS TO THE P!..ANIT BUOG~TJNG SYSTE:M.
TWO LAPTOP COMPUTERS.
SEVEN LAPTOF' COMPUTERS.
ONE lAPTOP COMPUTER WITH ADDITIONAL MEMORY.
ONE lAPTOP COMPUTER, TWO MONITORS AND ACCESSORIES.
CKV ~ PURCHASE ADDITIONAL TABlES AND CHAIRS.
CREATION OF A MOBILE APPLICATION TO cAPTURE AND REPORT EMPLOYoo EXPENSE REPORTS INTO BACKEND SYSTEM.
CKV- INSTALL CARPET JN CONFERENCE. ROOM.
PURCHASE ONE NIKON 07200 BODY FOR CAMERA.
CKV -NlNE lRIMBLE. JUNO HANO HELD MAPPING ANO GIS DEV!CES FOR MEASUREMENT FUNDAMENTALS ClASSES.
FDUR TEST CAP KITS FOR CONSTRUCTIDN ESS!;NTIALS CLASSES AND GAS MAIN TAPPING Cl.ASSES.
CKV y BUILD NEW CONFERENCE ROOM.
PURCHASE AUDIO VISUAL ADDITIONS TO l2, 15TH FLOOR CONFERENCE ROOM.
ONE LAPTOP COMPUTER AND DOCKING STATION_
WORKSTATIONS FOR L3. TfH FLOOR.
CKV - PURCHASE STANO-ALONE STORAGE CONTAINER.
ONE LAPTOP COMPUTER AND lWO MONITORS..
ONE LAPTOP COMPUTER.
CKV - OISPlA Y CASES. CONSTRUCT (4) BUILDINGS IN GAS CITY. (2) SMAll.E:R BUllDJNGS WILL BE •oPEN" COVERS SURROUNDING EXISTING TRAINlNG AREAS AND {2.} lARGER BUILDINGS WILL BE ENCLOSED PROVIDING SHELTER ALLOWING TRAINING TO CONTINUE IN All WEATHER CONDITIONS.
L3, 181H FLOOR BOARDROOM IMPROVEMENTS.
SSU Addftion5 Page2 of 5
CUSTOMERS BENE.FITEO
ALL ATMOS CUSTOMERS· MIXED
All.ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS- MIXED
ALL ATMOS CUSTOMERS m MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS~ MIXED
All.ATMOS CUSTOMERO -MIXED
A!.LATMOS CUSTOMERS - MlXED
ALLATMDS CUSTOMERS • MIXEO
ALL ATMOS CUSTOMERS - MIXEO
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS n MIXED
ALL ATMOS CUSTOMERS • MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS ~ MIXED
ALL ATMOS CUSTDMoRS • MIXED
All.ATMOS CUSTOMERS - MIXED
All ATMOS CUSTOMERS- MIXED
Al.LATMOS CUSTOMoRS ·MIXED
ALL ATMOS CUSTOMERS - MIXED
All ATMOS CUSTOMERS n M[XED
Al.LATMOS CUSTOMERS· MIXED
Al.LATMOS CUSTOMERS- MtXED
ALL ATMOS CUSTOMERS • MtXED
All ATMOS CUSTOMERS • MIXED
A!.LATIAOS CUSTOMERS- MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS· MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - M!XED
ALLATiulOS CUSTOMERS - M!XE:O
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
DATE PLACED IN GAS PLANT
LOCATION PURPOSE OF PROJECT IN SERVLCE
SHARED SERVICES EQUlPMENT JUNE
SHARED SERVICES !Nf"ORMATION TECHNOLOGY DECEMBER
SHARED SERVICES EQUIPMENT DECEMBER
SHARED SERVICES EQUIPMENT MARCH
SHARED SERVICES EOutPMENT JANUARY
SHARED SERVICES EQUIPMENT JUNE
SHARED SERVICES EQUIPMENT MARCH
SHARED SERVICES EQUIPMENT AUGUST
SHARED SERVICES EQUIPMENT APRIL
SHARED SERVICES EQUIPMENT AUGUST
SrtARED SERVICES EQUIPMENT SEPTEMBER
SHARED SERVICES EQUIPMENT SEPTEMBER
SHARED SERVICES EQUIPMENT MARCI-I
SHARED SERVICES INFORMATION TECHNOLOGY MARCH
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
SHARED SERVtCHl INFORMATION TECHNOLOGY DECEMBER
s~J\REO SERVICES INFORMATION TECHNOLOGY NOVEMBER
SHARED SERVICES INFORMATlON TECHNOLOGY MARCH
SHARED SERVICES JNFORMATION TECHNOLOGY JUNE
SHARED SERVICES INFORMATION TECHNOLOGY MARCH
SHARED SERVICES INFORMATION TECHNOLOGY JUNE
SHARED SEiRViCE$ EQUIPMENT JUNE
SHARED SERVICES INFORMATION TECHNOLOGY JUNo
SHARED SERVICES EOUIPMENT JUNE
SHARED SERVICES EQUIPMENT MARCH
SHARED SgRVICES EQUIPMENT JUIY
SHARED SERVICES EQUIPMENT JUNE
SHARED SERVICES STRUCTURES JUNE
SHARED SERVICoS EQUIPMENT JUNE
SHARED SERVICES INFORMATION TECHNOLOGY SEPTEMBER
SHARED SERVICES EQUIPMENT JUNE
SHARED SERVICES STRUCTURES JUNE
SHARED SERVICES INFORMATION TCCHNOLOGY SEPTEM!IER
SHARED SERVICES INFORMATION TECHNOLOGY SEPTEMBER
SHARED SERVICES EOUIPMENT JULY
SHARoD SERVICES STRUCTURES DoCEMBER
SHARED SERVICES EQUIPMENT SEPTEMBER
ALLOCATION
UNENO. PROJf.CTNO. cosrr1i TOWT~
71 010.2.7662 27,468 2,026
72 010.27663 27.442 2 024
73 010.27759 4a6,485 36,61:9
74 010.27770 252 7:98 18,645
75 Q10.27778 1 963 145
76 IJ10.27780 2.258 167
71 010.27793 6104 376
78 010.27872 3,574 264
79 010.27874 1763 130
80 010.27878 1.78S 130
81 010.28126 1,763 130
82 010.28Zl8 182-847 13 486
03 010.28239 16:ZQ43 13.427
84 010.28257 1.86246 13737
85 010.:2E311 36',910 2,722
86 010.28371 J-89.90:i!: 28.758
B7 010.28504 5 054 373
ea 010.28506 83,311 6,145
•• 010.28520 71.066 5.242
90 010.28542 43,617 32.17
91 010.28692 45,689 3,370
02 010.28702 130071S 95 936
93 010.28723 1,995 147
94 010.28660 4,624 356
95 010.28899 '2.299 170
96 010.25903 1.70S 126
07 010.29044 1 422.3-84 104,910
08 010.29045 1,216,599 89732
90 010.29046 375.1{;16 27.861
100 010.29048 1036514 76 44'9
TOTAL SSU GENERAL OFFICE ADDITIONS
[email protected]% 101 ILN. 1 - LN. 100] 16 972156 1 251 800
~ ~
104 SSU ADDITIONS· ALJGNE PlPfi PER BOOK °" 105 010.11580 2.869 962
10S 010.13018 17B,5Jl0
107 010.20087 15.244.756 -TOTAL sSU ALIGNE PIPE ADDITIONS AL..L..OCAn:o
@0% '!QB ILN. 105 - !-N. 1071 1.0 093 :i!.99
~ __ 1_10_
ATMOS ENERGYCORPORAT!ON,SHARED SERViCES
INTI:.RIM cosr ~l;COVE:RY ANO MTt A.PJU.sTMENT REPORT PROJECT REPORT Cf 201'6
DESCRIPTION OF COMPLETED PROJECTS DEOICATEO TO PUBLIC USE IN CALENDAR YEAR 2.016 [2}
NEW ORLE'.ANS Ml CONFERENCE ROOM.
Nim ORI.EANS AN TRADING ROOM.
BUILD APPUCATION TO CREATE PROJECTiONS USING HYPERION PLANNING.
CONVERT FROM IPROC LINE ITEM LICENSE TO USER UCENSE.
ONE LAPTOP COMPUTER AND DOCKING SIArloN.
ONE DESKTOP COMPUTER.
AUDIO VISUAL ADDITIONS TO LC3, 18TH FLOOR HR CONFERENCE ROOM.
PURCHASE PLOTTER FOR L2, 1 BTH FLOOR.
ONE LAPTOP COMPUTOR.
ONE LAPTOP COMPITTER.
ONE LAPTOP COMPlITER
PORT EXPANSION AND NElWORK INFRASTRUCTURE IMPROVEMENTS.
ADDITIONAL DYNATRACE LICENSES FOR FY 2016. ENHANCEMENTS TO GDO AND ACE TO ADDRESS RJ::QUESTS FROM OPERATIONS TO ENHANCE USEABILITY AND IMPROVE DATA ACCURACY FOR THE 1WO APPLICATIONS. MODIFY ANO ENHANCE THE PROCESS OF MAKlNG CHANGES WITHIN THE OMS AND ATLAS SYSTEM(S) IN ORDER TO ALLOW FOR UPDATES TO THE GAS SUPPLY PAGES ON-LINE. LC3, 5TH FLOOR TRAIN!NG ROOM CONSTRUCTION· FURNITURE & EQUIPMENT. CONSTRUCT (3~ NEW MEETINGfTRAINING ROOMS ANO PURCHASE AND INSTALL TRAINING ROOM FURNTIURE ANO AUOIO V!SUAL EQUIPMENT.
PURCHASE AND INSTALL DISHWASHER lN lC3, 18TH FLOOR BOARD ROOM.
INSTALL f41l CAMERAS AND [2.\ NVR'S ANO ASSOCIATED CAEUNG.
ADDITIONAL CENTRIFY ENTERPRISE !;DITION LICENSES.
CREATE AN APPLICATION TO TRACK AND MANAGE CONTINGENT WORKERS THROUGH THE. CONTRACT LIFECYCLE.
UPGRADE UC4TOVERSION 11. PURCHASE ORACLE SOFTWARE LICENSES INCLUDING DIAGNOSTIC PACKS, TUNING PACKS, ANO INT£RNET APPLICATION SERVER ENTERPRISE oDITION.
ONE LAPTOP COMPUTER.
ONE !'JI.AC STATION.
ONE LAPTOP COMPUTER ANO TWO MONITORS.
ONE LAPTOP COMPUTER
SAN FIBER SWTICH UPGRADE FOR LINCOLN CENTRE AND GVA FY17.
PRIMARY STORAGE CAPACITY EXPANSION FOR GVA AND LINCOLN CENTRE DATA CENTERS.
STORAGE BACKUP EXPANSION FY17.
SERVER REFRESH - REPlACE IBM SERVERS WITH UCS IN OVA ANO LINCOLN CENTRE.
AUGNEF'IPE.
IMPLEMENT THE JPP FRAMEWORK FOR AUGNE INTERFACE· INlTIAll Y THE APJGl. AAIGL ~Ol=i: GAS :SUPPL 'f INTERFACES. AUGNE PIPE IMPLEMENIAllON WILL IMPlEMENTTl'IE.AUGNE PIPE OPS SOLUTION FOR PIPEUNEICOMPLE~ TRANSPORT BILLING FUNCTIONAi.iTV FOR THE GTMS ANO GTMS-AES APPLICATIONS. THE IMPLEMENTATION EFFORT INCLUDES THE DEVELOPMENT OF AllGNEIORACL.E.
SSU Addftl¢n:;
Page3Qf5
CUSTOMERS BENEFITED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS-MIXED
AU.ATMOS CUSTOMERS- MIXED
All ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS r MJXED
ALL ATMOS CUSTOMERS -MIXED
ALL ATMOS CUSTOMERS - MlXED
ALL ATMOS CUSTOMERS • MIXED
ALL ATMOS CUSTOMERS - MIXEO
ALL ATMOS CUSTOMERS • MIXED
ALL ATMOS CUSTOMERS· MIXED
AU.ATMOS CUSTOMERS - MIXEO
Al.LATMOS CUSTOMERS • MIXED
AlLATMOS CUSTOMERS- MIXED
ALL ATMOS CUSTOMERS n MiXED
Al.LATMOS CUSTOMERS • M~XEO
Al.LATMOS CUSTOMERS- MIXED
ALL ATMOS CUSTOMERS - MIXtD
ALL ATMOS CUSTOME;RS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXE:D
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS~ MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL.ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS~ MIXED
ALL ATMOS CUSTOMERS- MIXED
At.•ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
All ATMOS CUSTOMERS • MDC:.ED
A!.LATMOS CUSTOMERS- MIXED
All.ATMOS CUSTOMERS • MIXED
DATE PLACED JN GAS PLANT
LOCATION PURPOSE OF PROJECT IN SERVICE
SHARED SERVICES INFORMATION TECHNOLOGY SEPTEMBER
SHARED SERVICES EQUIPMENT SoPTOMBER
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY SEPTEMBER
SHARED SERVICES INFORMATION TECHNOLOGY SEPTEMBER
SHARED SERVICES INFORMATION ToCHNOLOGY JULY
SHARED SERVICES EQUIPMENT SEPTEMBE;;R
SHARED SERVICES EQUIPMENT AUGUST
SHARED SERVICES INFORMATION lECHNOLOGY SEPTEMBER
SHARED SERVICES INFORMATION TECHNOLOGY SEPTEM'BER
SHARED SERVICES !NFORMATJON TECHNOLOGY SEPTEMBER
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY DEC!;MBE;R
SHARED SERV~CES INFORMATION TECHNOLOGY DECEMBER
SHARED SE:RVICES lNFORMAT!ON TECHNOLOGY SEPTEMBER
SHARED SERVICES STRUCTURoS OECEM6oR
SHARED SERVICES EQUIPMENT OCTOBER
SHARED SERVICES STRUCTURES DECEMBER
SHARED SERVICES INFORMATION Tl;CHNOLOGY DECE:MBER
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
SHARED SERVICES lNFORMATION TI:.GHNOlOGY DECEMBE:R
SHARl;D SERVICES iNFORMAT!ON T~CHNOLOGY DB:C~MBER
SHARED SERVICES lNFORMAnDN TECHNOLOGY DECEMBER
SHARED SERVICES INFORMAT~ON TECHNOLOGY SEPTEMBER
SHARED SERVICES INFORMATION TECHNO\_OGY DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
SHARED SERVICES lNFORMATION 1ECHNOLOGY DECEMBER
SHARED SERVICES INFORMATION TOCHNOLOGY DECEMBER
SHARED SERVICES INFORMATION 1ECHNOLOGY DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
SHARED SERVICE:S INFORMATlON TECHNOLOGY SEPTEMBER
SHARED SERVICIOS INFORMATION TECHNOLOGY SEPTCMl!ER
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
LINE NO. 111
112
113
114
116
116
117 ----11!_ ---1:!]_
120
121
122
~
~;:
126
127
128
129
130
131
132
133
134
135
130
137
138
139
HO
141
142
143
H<
146
146
147
14&
149
150
151
ALLOCATION
PROJECT NO, COST f1l TOWTX
ATMOS ENERGY CORPORATlOl\I, StlAR.E:O SERVICES
INTERIM COST RECOVERY AND RATE AOJUSTMENi' R.EPORT
PROJECT REPORT CV 2016
DESCRIPTION OF COMPLETED PRO.IErn.s DEDICA1EO 10 PUBLIC: USE IN CAL~NOAR YEAR 2016 (2)
CUSTOMERS BE.l\IEFITED
ssu ADDfflONS. DlSIR/BurJON AND MARl<E.tJNG PER aooK all: 10.Cl'9%
IMPLEMENT SHARED SYSTEMS PlATfORM SOl..UTION FOR MID-TEX PRESSURE CONTROL AND SHARED SERVtCE GAS CONTROL. CREATE SHARED REPOSITORY WITH ST ANOARO OBJECTS.
010.2.1827 :221 600 22,370 UPGRADE FRAN KUN TN VERSION TO LATEST RELEASE.
010.26729 247 745 25 010 SS PC REPLACEMENT PROJECT FOR FYIO.
010.27011 :;i:i:i,1e7 3,964 SET UP GAS CITY METER WA!.LS.
010.27350 22 205 2,:2112 REPLACE THE DMVPN HEADEND ROUTER. MICROSOFT SOFTWARE ASSET REVIEW TRUEUP ~AFTER A SOF1WARE REVIEW FOR MJCROSOFT SOFTWARE, SEVERAL
010.28221 287,32:2 2:9,005 LICENSES NEED TO BE PROCURED.
TOTA~ SSU DISTRIBUTION AND MARKfTINO!
ADDITIONS ALLOCATED @110.09%
(lN. 112 - LN. 1181 818:040 82581
SSU ADDrTIONS • GREENvrLLE AVENUE PER BOOK fi 2.77"A
STRUCTURE IMPROVEMENTS TO THE GR~ENVIL.l.S AVENUE BUELOING. THESE IMPROVEMENTS INCLUDE REPLACING THE ROOF,
010.11620 166,396\ t1 aae NEW HVAC SYSTEM, ELECTRICAL ANO SECURITY SYSTEM, ETC.
TOTAL SSU Gfl:E.E.NVILLE AVENUE AOPITION$
ALLOCATED@ 2.77% (lN, 121} lGS,386~ (18381
SSU ADOfTIOllS • CUSTOMER SUPPORT PER BOOK"" •.70%
010.12625 r4 005' 1388'
010.23155 12& 12
010.24707 31819 3,085
010.25167 (975l 195!
010.25429 11 1
010.25933 1211491 f2,051~
010.26050 48,261 4,680
010.26567 323.728 31.390
010.26568 648,SOB 62,911
010.26587 118 11
010.28659 151 4'96 14,690
010.26072 43.00<l 4265
010.266:29 1,311 398 127,159
010.26955 215,680 20913
010.27093 1.160 112
010.27099 147 595 14 3'06
010.27205 10.245 993
010.27266 198 615 19,259
010.27316 1 763 171
010.27320 311.240 30179
010.27772 1,763 171
010.27849 315.909 30632.
010.27904 1a.aa7 1807
010.28077 242,699' 23,533
010.28095 8467 621
010.26192 3,231 313
EQUtPMENT FOR AMARILLO CONTACT CENTER - OFFtCE FURNITURE, DESKS, CHAIRS, ETC.
MAKE CUSTOMER NOTIFICATION CAllSfTEX.TS ATTHREE POINTS FOR APPOINTMENTS: (1)APPOINTMENT REMINDER ON DAY PEFORE. [2) APPROXIMATE!. Y ONE HOUR PRIOR TO ToCH ARRIVAL. (3) FINAL NOTIFlCATION WHEN TECH GOES EN ROUTE TO ORDER.
PHASE Ill OF CUSTOMER CONTACT CENTER COMMUNICATIONS INFRASTRUCTURE MODERNIZATiON.
ENHANCE THE BJ REPORTING PORTFOLIO FOR REVENUE MANAO!EMENT AND GAS ACCOUNTING.
FY 2010 PC ANO MISCoLLANEOUS DESKTOP ANO VOi EQUIPMllNT REPLACEMENTS,
QUARTERLY RELEASE FOR CSS SAi' LANDSCAPES
ASPECT va.o UPGRADE. UPGRADE WORKFORCE MANAGEMENT VERSION 7.3 SYSTEM ONIO NEW SERVERS.
CAPITAL FUNOINO FOR WEB ANO MOBILE ENHANCEMENTS FOR FY 16.
CSS FEBRUARY 2016 RE.LEASE..
PURCHASE HITACHI LCD PROJECTOR FOR CONFERENCE ROOM.
THIS PRoJECT IS FOR INTERNAL ANO EXTERNAL LABOR FOR ARCHIVING OBJECTS WITHIN SAP 11su1.
CC PC REPLACEMENTS FY16. BW NLS PROGRAM TARGETING THE FOLLOWING SCOPE: BW SUPPORT PACK IMPLEMENTATION; Nl...SASED aw DATA ARCHIVING INITIATiVE. LOST AND UNACCOUNTED FOR GAS ENHANCEMENTS AND REPORTlNG. CHANGES WILL B~ MADE: IN 'rHE BUSINESS PROCESS FOR SAP. Bl ANO Svolo.
ONE DESKTOP COMPUTER AND MONITOR.
VMWARE VlEW 6 FARM UPGRADE - PURCHASE OF BLADES TO UPGRADE THE VDI POOLS FOR THE CONTACT CENTERS.
I Ann u"AC UNIT TO ELECTRICAL ROOM. 1 ue'-'KADE THE CONVERGYS INTELLIGENT VOICE PORTAL (IVP) FROM VERSION 6.7 TO VERSION 8.1 AND INSTALL NUANCE VOCALIZER VERSION 5.7 AND RECOGNIZER VERSION 10.
ONE LAPTOP COMPUTER.
CSS FY16APRILRELEASE.
ONE lAPTOP COMPUTER.
CAPITAL FUNO!NG FOR JULY fY16 CSS RELEASE.
UPS BATTERIES AND CAPACITORS/FANS REPLACEMENT.
PROJECT TO ENABLE CAMPAIGNS FOR CUSTOMERS WHO HAVE RECElVEO WARNING lAGS OR HAVE CUSTOMER SIDE LEAKS.
WIREL5$$ PROJECTOR KlT UPGRADE.
TWO LAPTOP COMPUTERS.
S:!;U Additions Page4 of 5
ALL ATMOS CUSTOMERS- MIXED
ALL ATMOS CUSTOMERS - MIXED
All.ATMOS CUSTOMERS - MIX:E.D
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS • MIXED
AU.ATMOS CUSTOMERS- MEX.ED
ALL ATMOS CUSTOMERS • MIXED
Ai.LATMOS CUSTOMERS - MIXl::D
ALL ATMOS CUSTOMERS - MIXED
Al.LATMOS CUSTOMERS~ MIXED
ALL ATMOS CUSTOMERS - MIXED
AlLATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS- MIXED
ALL ATMOS CUSTOMERS - MIXEO
ALL ATMOS CUSTOMERS • MIXED
ALL ATMOS CUSTOMERS- MIXED
ALL ATMOS CUSTOMERS~ MIXED
ALL ATMOS CUSTOMERS- MIXED
ALL ATMOS CUSTOMERS - MIXED
All ATMOS CUSTOMERS~ MIXED
All.ATMOS CUSTOMERS· MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS- MIXED
All.ATMOS CUSTOMERS· MIXED
AU.ATMOS CUSTOMERS - MIX~O
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MlXED
ALL ATMOS CUSTOMERS n MIXED
ALL ATMOS CUSTOMERS - MIXED
ALL ATMOS CUSTOMERS - MIXEO
DATE PLACED IN GAS PLANT
LOCA110N PURPOSE OF PROJECT IN SERVICE
SHARED :SERVICES INFORMATJON TECHNOLOGY SEPTEMBER
SHARED SERVICoS INFORMATION TECHNOLOGY DECEMBER
S!lAREP SERVICES S1RUCTURES MARCH
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
SHARED SERVlCE.S INFORMAT!ON TECHNOLOGY DECEMBER
SHARED SERVICES STRUC1URES JANUARY
SHARED SERVICES EQUIPMENT JANUARY
SHARED SERVICES INFORMATION TE;CHNOLOGY MARCH
SHARED SERVICES INFORMATION TECHNOLOGY MARCH
SHARED SERVICES INFORMAT!ON TECHNOLOGY MARCH
SHARED SERVICES INFORMAT[ON TECHNOLOGY MARCH
SHARED SERVICES INFORMATION TECHNOLOGY JUNE
.SHARED SERVICES INFORMATION TECHNOLOGY JUNE
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY SEPTEMBER
SHARED SERVICES OUUIPMENT MARCH
SHARED SERVICES INFORMATION TEC}-INOLOGY DECEMBER
SHA.QED SERVICES lNFORMATION TECHNOLOGY DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY DE;CE;MBER
SHARED SERVICES INFORMATtON TECHNOLOGY MARCH
SHARED SERV!ci:;.s INFORMATION TECHNOLOGY DECEMBER
SHARED SERVICES EQUIPMENT DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
SHARED SERVICES lNFO:RMATION TECHNOLOGY SEPTEMBER
S!-1.ARED SERVICES 1NFORMATlON TECHNOI OGY DECEMBE:.~
SHARED SERVICES EQUIPMENT SEPTEMBER
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
SHARED SERVICES EQUIPMENT SEPTEMBER
SHARE:D SERVICES INFORMAnoN TECHNOLOGY DECEMBER
Sl:-lARED SERVICES EQUIPMENT SEPTEMBER
SHARED SERVICES INFORMATION TECHNOLOGY SEPTEMBER
UNENO.
152
153
154 155
106
~ ~ ~ _____j£Q_ -~16~1-
l='ROJ!:.CTNO. COSTl11
010.28708 718.22.
010,29176 9a.2fill
TOTAl $$U CUSTOMER SUPPORT ADDITIONS ALLOCATED@: 9.70%
!L.N. 106 - lN. 1531 4178 652
TOT Al SHARED SERVCCES ADDITIONS
(LN. 101 + LN. 108 + LN. 117 + L.N.122 io lN. 154) 39995 700
NOTES:
AllOCATIOl'il rowrx
$,964
'9 334
4051&2
427 55-2
ATMOS ENERGl'CORPORATION,SHARED S.£RVlC:ES
INTERIM COST RECOVERY ANO MT.E APJUSTMENT REJIORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 201'8 [2t
UPDATE AV lN FOUR TRAINING ROOMS: CAMERON, BLUEBONNET, AA.NGSf:i.. PURCHASE (B} 75" MONITOfi:$ Wl'f'H A:S.SOCFATED EQUIPMoNT. OAllUNG ANO 1-1\BOR. PURCHASE FURNITURE IN
CUSTOMERS BENEFITED
AL.LATMOS BLUEBONN~T AND RANGE:R CONFERENCE ROOMS. CUSTOMERS - MIXED
All ATMOS CSS ENHANCEMENTS FOR THE FIRST QUARTER OF FY17. CUSTOMERS· MIXED
{1} The "COST'' column reflects the e:apil.aElzed portion of U1e co:st only. {2} The "'DESCRIPTION OF COMPLETED PROJEC'fS OE:D!CATS.0 TO PUBLIC USE IN CA'l.E.NDAf::t Ye:AA :2016'' i;:olumn des"Cribes ca.plt.alized costs only.
SSUAdditions Pages ofS
MTEPl.J\CEO INGAsPl.J\NT
LOCATION PIJRPOSE OF PROJECT IN.SERVICE
SHARED SERVICES E;OUIPMENT DECEMBER
SHARED SERVICES INFORMATION TECHNOLOGY DECEMBER
UNENO.
1
2
3
4
5
6
7
6
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
ALLOCATION PROJECT NO. COSTl11 TOWTX
ATMOS ENt.RGV CORPORJ!fflON, SHAREO .SERVICES INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJcCTRcPORTCY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016121
SSU RETIREMENTS· GENERAL OFFICE PER BOOK @7.38%
010.10854 r42.431l 13.130)
010.10925 1360,724\ ,,,,,606\
010.10970 r540,75Sl rae,8841
010.11060 13,125) 1231\
010.11001 192150\ 16,797\
010.11110 14.479) 13301
010.11126 134119\ 12.5161
010.11227 143,374\ 13199
010.11239 12. I 18,3021 r156,238
010.11347 /22 501) (1.660
010.11361 12,716! 1200
010.11364 16,731! (496
010,11369 12,515 509 1185.535
010.11395 4,969 366
010.11468 15.31Z 1392
010.11473 4,86-0 344
010.11543 11.070 179
010.11572 1357 622 126.377
010.11636 <14,607 11 077
010.11659 12,142 (158
010.11665 (1,4<18 1108'
010.11668 11.470 1108
010.11669 14.50'.n 1332'
010.11690 196;1.90 17.102'
010.11697 11.466 1108
010.11899 (12100 1892
010.11706 (6,174 14551
010.11761 1229.445 118,923
010.11766 118283' r1,3481
010.11775 12,180 1161
010.11778 13,184 1235
010.11780 rs120 la78
010.11784 (1,438 11061
010.11787 12,724 1201
010.11795 1157611' <11,6251
010.11797 r1,649' (1221
010.12195 13.483 12571
010.12196 15,8561 14321
010.12426 128 (2)
010.12441 11.1641 1861
010.12552 (4,087 1301\
010.12937 11,016l 1751
010.12993 {2943 (217l
010.13255 f10,099l 17451
010.13443 126,48m 12,101)
010.13461 11,6381 11211
010.13748 12500 11841
010.13751 15,754 14241
010.13979 1407491 r3.0061
010.14024 [4,182 /3081
010.14-088 rU84' 11461
010.14129 18616 1635
010.15290 17.967' /588
010.15327 17,246 (534
010.15445 ra,571 12631
010.15571 r1328' 1981
PURCHASE SOFTWARE LICENSES FOR HEAT TO HANDLE ADDITIONAL DATABASE IN HR.
PURCHASE SOFTWARE FOR ENERLINK PHASE 11
PURCHASE SOFTWARE FOR OFFICE APPLICATIONS
PURCHASE COMPUTER EQUIPMENT - SERVERS & SOFTWARE
PURCHASE PAYROLL TAX SOFTWARE
PURCHASE TIMEKEEPING SOFTWARE
CENTRALIZED WIRELESS LAN ADMINISTRATION SERVER. UPGRADE SERVERS IN DATA CENTER TO STAY CURRENT wm-1 TECHNOLOGY AND WARRANTIES,
H.R. DASHBOARD I SUPERVISOR REPORTING. UPGRADE SERVERS IN DATA CENTER TD STAY CURRENT ll\llTH TECHNOLOGY AND WARRANTIES.
REMOTE PHONE CONVERTERS.
SECURITY BADGE PRINTERS FOR THE CONTACT CENTERS.
IMPLEMENT CASH RECONCILICATION SOLUTION
WACO CONTACT CENTER OFFICE CHAIR AND EQUIPMENT.
COMMUNICATION SOFTWARE FOR MOBILE DEVICES.
WACO CCC IMPROVEMENTS.
A TT DATA INFRASTRUCTURE UPGRADE FY09.
QUARTERLY PC REPLACEMENT.
CABINET BUILD OUT AND ELECTRICAL WIRING AT CHARLES K. VAUGHN.
ONE PRINTER.
TWO LAPTOP COMPUTERS.
ONE LAPTOP COMPUTER.
OVERHEAD PROJECTORS. ITEMS TO FACILITATE TRANSPORTATION AND HANDS.ON TRAINING AT CKVCENTER.
ONE LAPTOP COMPUTER. ITEMS NEEDED FOR MEASUREMENT TRAINING ACTIVITIES AT CHARLE:S K. VAUGHN FLOW LAB IN PLANO.
THREE LAPTOP COMPUTERS.
154 REPLACEMENT COMPUTERS FOR FY 2011.
TWO LAPTOPS AND SEVEN DESKTOP COMPUTERS.
ONE COMPUTER AND PRINTE:R.
ONE LAPTOP COMPUTER.
WELDING EQUIPMENT FOR CHARLES K. VAUGHN.
ONE LAPTOP COMPUTER.
ONE LAPTOP COMPUTER.
CHARLES K. VAUGHN ADDITIONAL CONSTRUCTION.
ONE LAPTOP COMPUTER.
ONE DESKTOP COMPUTER.
ONE LAPTOP COMPUTER.
RYCOM MARKER BALL LOCATOR - MODEL 8891 G. REFRIGERATION FOR ATTENDEES ATTENDING TRAINING CLASSES AND EMPLOYEES AT CHARLES K. VAUGHN.
ONE DESKTOP COMPUTER AND SOFTWARE.
ONE DESKTOP COMPUTER.
TWO LAPTOP COMPUTERS.
NEW COMPUTER EQUIPME:NT FOR NEW EMPLOYEE.
NINE LAPTOP COMPUTERS, DOCKING STATIONS AND SOFTWARE.
ONE LAPTOP COMPUTER. 36" PORT-A-COOL FAN/3 SPEED/BELT DRIVE # PAC 2.K363S - FOR WELDING SHOP AT CHARLES K. VAUGHN. VISIX PLAYER, MEDIA PLAYER, CABLES, CONNECTORS, SUPPORT AND TRAINING OF EQUIPMENT AT CHARLES K. VAUGHN.
CKV -CREATION OF ATMOS !OS APPLICATION FOR QUICK RESPONSE (QR) CODES TO BE USED FOR CKV TOURS AND TRAINING.
ONE DESKTOP COMPUTER, UPS. MONITOR STAND AND VISIO.
MICROPHONES FOR PRESIDENTIAL ROOM AT CHARLES K. VAUGHN. MCELROY FUSION EQUIPMENT FOR FRANKLIN. TN AND PLANO, TX-CONSTRUCTION 102 AND 200 SERIES. CKV- TWO DIGITAL CAMERAS ll\llTH LENS ANO FLASHES, AND ONE VIDEO CAMERA.
CKV - PROACTIVE SOFTWAREFTRAINING FOR CORROSION CLASS.
METHANE DETECTOR FOR FLOW LAB.
ONE DESKTOP COMPUTER, PRINTER AND SOFTWARE.
SSU Retirements Page 1 ofS
CUSTOMERS BENEFITED LOCATION PURPOSE OF PROJECT
i I ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY All ATMOS SHARED
CUSTOMERS -MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOM!ORS - MIXEO SE:RVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS· MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS ·MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS -MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS- MIXED SERVICES INFORMATION TECHNOLOGY ALLATll!OS SHARED
CUSTOMERS· MIXED SERVICES INFORMATION TECHNOLOGY ALLATll!OS SHARED
CUSTOMERS - MIXED SERVICES INFOR,,.ATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS- MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MJXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHAREO
CUSTOMERS - MIX!OD SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES STRUCTURES ALL ATMOS SHARED
CUSTOMERS - MIXED SE:RVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS· MIXED SERVICES ll>IFORMATION TECflNOLOGY ALL ATMOS SHARED
CUSTOMERS-MIXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS -MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY AlLATl\!OS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MJX!OD SERVICES INFORMATION TE;CHNOLOGY ALL ATMOS SHARED
CUSTOMERS ·MIXED SERVICES INFORMATION TECHNOLOGY ALLATll!OS SHARED
CUSTOMERS -MIXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS· MIXED SERVICES INFORMATION TECHNOLOGY ALLATll!OS SHARED
CUSTOMERS -MIXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MJXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS -MIXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS -MIXED SERVICES INFORMATION TECHNOLOGY All.ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION T!OCHNOLOGY
ALL ATMOS SHARIOD CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALLOCATION LINE NO. PROJECT NO. COSTf11 TOWTX
57 010.16680 126,318) [1,941
58 010.16720 11560' 11151
59 010.17009 f.l,230 (238
60 010.17268 111.532' 18511
61 010.17289 12,635 1194)
62 010.17328 13,2361 1239\
63 010.17349 (37,751) f2.7a4)
e4 010.18934 110,2321 (755\
65 010.19839 1176-541 11,302)
66 010.22130 [9,296) 1686\
57 010.22131 [2,783) C105l
68 010.22565 [5835) 14301
69 010.23160 13,607) (2661
70 010.23347 (31,525) (2,325)
71 010.23386 C11 0861 11.5551
72 010.23411 f18,899l 11,3941
73 010.23427 127 418l 12.0221
74 010.23679 11,2931 195)
75 010.23689 (16,606) (1,225)
76 010.23692 111 961\ 1882)
77 010.23781 [500,642) (41,793)
78 010.24423 178.072l f5,75Bl
79 010.24428 (1,5461 1114
80 010.24430 115.204\ 11,121
81 010.24431 16110) (451
82 010.24433 147,433) 13499
83 010.24466 [7,096) [523
84 010.24760 117.312 11,277
85 010.25270 14,700 1353
Bll 010.25880 r.10,181 11,488
87 010.26502 (34 719 r.1,581
SB 01026697 1332,038 124 490
89 010.26746 f.32,068 ;.1,365
90 01026780 16593 1486
91 010.26786 (2,9451 !2.17
92 010.26791 13.158 (233
93 010.26823 121,326 (1 573
94 01026824 18,943 1660
95 010.26825 110479 1773
96 010.26826 17,061 1521'
97 010.26827 111,3';9 1839
98 010.26836 17109 1524
99 010.26838 16,652 !491
100 010.26839 14,831 1356
101 010.26841 C11 405 11,579
102 010.26a45 (9,856 1727
103 010.27105 11.900 !140
104 010.27133 120,649 11,523
105 010.27152 16,583 (486
106 010.27178 118.655 11,376
107 010.27215 IB,522 1481
108 010.27222 114,654 11,081
109 01027311 15,744 f424
110 010.27440 112.418 1916
ATMOS ENERGY CORPORATION, SHAREO SERVICES INTERIM COST RECOVERY ANO RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPl.ETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 (2]
CKV - PURCHASE FAN POWERED METAL HOOD EXHAUST SYSTEM FOR WELDING BAYS, CONSTRUCTION, INSTALLATION ANO DEMOLITION OF EXISITING SYSTEM,
CKV -PURCHASE GX SOFTWARE FOR SUITE SUPPORT. CKV - PURCHASE STORYLINE SOFTWARE FORE-LEARNING DEVELOPMENT. CKV -PURCHASE LEAK DETECTION EQUIPMENT FOR LEAK SURVEY CLASSES MID DEMONSTRATIONS. CKV- PURCHASE STACKABLE NOISE PANELS FOR CUBICLES TO CUT NOISE.
CKV - PURCHASE STORAGE BUILDING FOR TRAlNING CENTER. CKV- OFFICE RECONFIGURATION· PURCHASE FURNITURE, CABLING AND PERMITS.
PURCHASE WELDING MACHINE FOR WEDLING LAB AT CKV.
ITRONS FOR TRAINING METER READERS AT CKV. CKV- PURCHASE LINE LOCATORS AND AIJTO CALIBRATION STATION FOR TRAINING.
CKV- PURCHASE ELECTROFUSION MACHINE FOR TRAINING PURPOSES. CKV- PURCHASE OUTDOOR UNIT WITH ROLL-UP DOOR FOR CKV STORAGE.
CKV- PURCHASE MIWIERX Ml WIRELESS INSTRUMENT FROM ERX. CKV - GAS CITY PHASE 1 UPGRADE, THESE ITIOMS REQUIRE CONSTRUCTION AS NO OFF TiiE SHELF PRODUCT rs AVAILABLE FOR PURCHASE. WILL BE USED FOR THE NEW INTEGRATED LEARNING PLAN ANO Will BE USEO DURING TRAINING CLASSES. CONCRETE WORK TO BUILD TWO PRACTICE WALLS.
CKV - PURCHASE UPS BA nERY STRING REPLACEMENT.
CKV - PURCHASE ADDITIONAL IPADS FOR TECHNICAL TRAINING CLASSES AT CKV CENTER. QUOTE INLCUDES APPLE CARE AND CASES. PURCHASE FLOW LAB ACOUSTIC ABSORBER WHICH WILL BE AnACHED TO THE WALLS AND CEILING. CKV ·PURCHASE ACCESS POINT, PATCH ANTENNA AND MOUNTING FOR SERVICE TECHS INTEGRATED TRAINING.
CKV - BUY ANO INSTALL FOUR NEW WORKSTATIONS.
CKV -ROOM RE-MODEL, INSTALLING CARPET. RECTRICAL AND CABLING.
CKV - GAS CITY EXPANSION. MODEL#5 PROVERS-10M DRESSER PROVER TIOCHNICAL TRAINING CKV CENTER.
LAPTOP FOR PROVERS TECHNICAL TRAINING FOR CKV.
MUELLER VALVE CHANGER FDR TECHNICAL TRAINING AT CKV.
PLCS VALVE CHANGER FOR TECHNICAL TRAINING AT CKV.
SMART CAL STATION FOR TECHNICAL TRAINING AT CKV. RIGID PIPE TiiREADING MACHINE FOR WELDING LAB TECHNICAL TRANING CKV. GAS CITY INLET VALVE CHANGEOUT. PROJ!;CT INCLUDES PLUMBING, EXCAVA llON AND BACKFILL AND SOIL STABILIZATION.
CKV - R!OPLACE GATE MOTOR. CONSTRUCT NEW TRAINING WALL WITH FOUR FOOT SIDEWALKS AT GAS CITY. INSTALL CONCRETE PAD AND TWO LARGE STORAGE CONTAINERS AT CKV.
CKV AV UPGRADES.
CKV FURNITURE FOR TRAINING.
THREE LAPTOP COMPUTERS CKV - WILTON VISE, 10116 800N MACHINEST FLEET BENCH VISE TO BE USED FOR CONSTRUCTION CLASSES. CKV -DEASON 2 IN .Jl IN POLY PIPE PEELER USED FOR CONSTRUCTION CLASSES. CKV • VISUAL INTERACTIVE DRIVING SIMULA TOR IN CAB MODEL LX 38(1) USED FOR CLASSES.
CKV ·SECOR FUSION UNIT AND TWO INSERTS USED FOR CLASSES.
CKV - HEAL TH CONSULTANTS GMl3-SOO WATCHER FOR CLASSES. THREE TIMBERLINE LONG HANDLE POLY SQUEEZE TOOLS FOR ADVANCED SERVICE CLASS 314-2 IN.
FOOTAGE LONG HANDLE STEEL SQUEEZE TOOL.
CKV- CENTRAL PROCESSOR MSA 340 (2) TO !IE USED FOR CLASSES. CKV- MT DEASON AUTOFUSE PROCESSOR TRIPAFS00001 (2) 2,600 TO BE USED FOR CLASSES. CKV - RYCCM PIPE AND CABLE LOCATOR 8Bll9V3(2) TO BE USED FOR CLASSES. MOBILEYE UNITS INSTALLED ON VEHICLES TO ENSURE SAFE DRIVING TECHNIQUES.
CKV - PUCHASE OPERATIONS AUDIO VISUAL EQUIPMENT.
ONE LAPTOP COMPUTER WITH ADDITIONAL MEMORY.
CKV - PURCHASE ADDITIONAL TABLES AND CHAIRS.
CKV - INSTALL CARPET IN CONFERENCE ROOM. CKV -NINE TRIMBLE JUNO HAND HELD MAPPING AND GIS DEVICES FDR MEASUREMENT FUNDAMENTALS CLASSES. FOUR TEST CAP KITS FOR CONSTRUCTION ESSENTIALS CLASSES AND GAS MAIN TAPPING CLASSES.
CKV - BUILD NEW CONFERENCE ROOM.
CKV -PURCHASE STAND-ALONE STORAGE CONTAlNER.
CKV -DISPLAY CASES.
SSU Retirements Page 2 of 5
CUSTOMERS BENEFITED LOCATION PURPOSE OF PROJECT
All ATMOS SHARED CUSTOMERS· MIXED SERVICES EQUIFME;NT
ALL ATMOS SHARIOD CUSTOMERS -MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS • MIXED SERVICES INFORMATION TECHNOLOGY
All ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS • MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS-MIXED SERVlCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
All ATMOS SHARED CUSTOMERS • MIXl':D SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVlCES EQUIPMENT
ALLATMCS SHARED CUSTOMERS-MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS· MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES STRUCTURES
ALLATMCS SHARED CUSTOMERS-MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS • MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS-MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS-MIXED SERVICES EQUIPMENT
All ATMOS SHARED CUSTOMERS-MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVlC!;S EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALI.ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
ALLAT1'!0S SHARED CUSTOMERS ·MIXED SERVICES EQUIPMENT
LINE NO.
111
112
113
114
115
116
117
118
119
120
121
122
123
124 _____1£_ ____g§_
127
128
129
130
131
132
133
134
135 ~ _____!R_
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
PROJECT NO. COST/11
010.27662 (27.468l
010.27663 127.4421
ADMIN010 (31,79lll
AOMIN010 rl,020.8351
AOMIN010 (641 5ll4)
ADMIN010 1190.2381
AOMIN010 11,469 953)
AOMIN010 131,6551
AOMIN010 118 020l
ADMIN010 (134,287)
ADMIN010 126,759,7551
AOMIN010 943399
ADMIN010 1943,3991 TOTAL SSU GENERAL OFFICE RETIREMENTS ALLOCATED@ 7.38%
ILN. 1 - Liii, 1231 138 8353791
ALLOCATION TOWTX
(2,026)
12 0241
(2,3451
175.2931
[47 319)
114,0311
1108418)
12,3351
(1,3291
(9905l
11.973,7001
69,582
[69,5821
12 8643531
ATMOS ENERGY CORPORATIOl'I, SHARED SERVICES INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
.Pft.OJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016 C2l
NEW ORLEANS IW CONFERENCE; ROOM.
NEW ORLEANS AN TRADING ROOM.
AOMIN
ADMIN
ADMIN
AOMIN
ADMIN
AOMIN
AOMIN
AOMIN
AOMIN
ADMIN
ADMIN
SSU RETIREMENTS- DISTRIBYnDN AND MARl<ET/NG PER BOOK@ 10.09%
010.11353 (532) 154)
010.11635 14,607 1,475
01024464 13485) 1352
01027011 139,1671 13,954
010.27105 1.900 192
010.27662 27468 2.773
010.27663 27,442 2,770
TOTALSSU DISTRIBUTION ANO
MARKETING RETIREMENTS
[email protected]% ILN.128-LN.134l 28 233 2850
SSU REillREMENTS- CUSTOMER SUPPORT PER BOOK'
010.11054 (1,082,6661 1104 980
010.11363 1260.385 125,248
010.11395 15049 (490
010.11404 1112.672 110,925
010.11473 14.560 1452
010.11512 (345,685 133 517
010.11513 1609.188 (59,070
010.11514 11 843126 1178,718
010.11538 1456,357 144251
010.11540 1335.963 1:12,5771
010.11565 1337173 132694
010.11570 1257.084 124,926
010.11571 1296 i!fj0 128,785'
010.11629 1561,157 154412
010.11671 (5.861 (568
010.11706 15878 1570
010.11783 110,307 1999'
010.11794 12.558 1248
010.12310 122541 12.186
010.12407 15,2251 1507
010.12994 12.778 (269
010.13377 12184 1212
010.13381 11,405 1136\
010.13694 121.090 (2,045
010.13910 (12054 11.169
010.14059 11,506 (146
010.18860 124.8591 (2,410
LEASE IMPROVEMENTS FOR OFFICE- SSU PORTION.
CABINET BUILD OUT ANO ELECTRICAL V\llRING AT CHARLES K. VAUGHN. BATTERY PROCESSOR ANO CTS INSERTS FOR FRANKLIN TECHNICAL TRAINING CKV.
SET UP GAS CITY METER WALLS.
ONE LAPTOP COMUTER WITH ADDITIONAL MEMORY.
NEW ORLEANS AN CONFERENCE ROOM.
NEW ORLEANS IWTRADING ROOM.
9.71>%
CUSTOMER SERVICE COSTS. IMPLEMENT ENAHANCEO CREDIT CARO PAYMENT OPTIONS FOR CUSTOMERS.
WACO CONTACT CENTER OFFICE CHAIR ANO EQUIPMEl'lT.
CALL CENTER MANAGEMENT TOOL FOR ESCALATED CALLS.
WACO CCC IMPROVEMENTS.
FACT A RED FLAGS - SECURITY & ACCT CENTER. CUSTOMER VERIFICATION SOLUTION TO COMPLY WITH FAIR ANO ACCURATE CREDIT TRANSACTIONS ACT (FACT A).
FACT A RED FLAGS - FRAUD OVERSIGKT. IMPLEMENTATION OF NEW SCREENS FDR CUSTOMER SERVICE APPLICATION. PROTECTION OF "SENSITIVE PERSONAL INFORMATION" TO COMPLY WITH FAIR AND ACCURATE CREDIT TRANSACTIONS ACT (FACTA). IMPLEMENTATION OF NEW SCREENS FOR CUSTOMER SERVICE APPLICATION.
CUSTOMER FRAUD MONITORING APPLICATION TO COMPLY WITH FAIR ANO ACCURATE CREDIT TRANSACTIONS ACT (FACT A) REGULATION. UPOATE;STO ONLINE ACCOUNT CENTER TO COMPLY WITH FAIR AND ACCURATE CREDIT TRANSACTIONS ACT (FACTA) REGULATION.
REPLACEMENT PCS FOR CUSTOMER CONTACT CENTERS.
12 OESKfOP COMPUTERS.
FOUR DESKTOP COMPUTERS.
154 REPLACEMENT PCS FOR CONTACT CENTERS
ONE LAPTOP COMPUTER.
12 OESKfOP COMPUTERS. FOUR DESKTOP COMPUTERS WITH DUAL MONITORS ANO STANDARD SOFTWARE.
TWO DESKTOP COMPUTERS.
ONE LAPTOP COMPUTER.
ONE LAPTOP COMPUTER.
FIVIO ADDITIONAL WORKSTATIONS FOR DISPATCH IN PLANO OFFICE.
FOUR LAPTOPS ANO SOFTWARE.
ONE LAPTOP COMPUTER. BUILD OUT OFFICE ANO INSTALL FABRIC PANEL DIVIDERS IN PLANO DISPATCH.
SSU Retirements p;;1ge 3 of 5
CUSTOMERS BENEFITED LOCATION PURPOSE OF PROJECT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS -MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS -MIXED SER\llCES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY ALLA"IMOS SHARED
CUSTOMERS -MIXED SERVlCES INFORMATION TECHNOLOGY ALLA"IMOS SHARED
CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS- MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES SlRUCTURES
ALL ATMOS SHARED CUSTOMERS-MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY
ALL ATMOS SHARE;D CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlC!;S INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALLA"IMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS- MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES INFORMATION TECHNOLOGY
ALLA"IMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS-MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
LINElllO.
166
167
168
169
170
171
172
173 174 175 176
177
178
179
160
181
182
183
184
165
186
167
186
189
190
191
192
193
194
195
196
197
198
199
ioo
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
<17
218
219
PROJECT NO. cosTm
010.22547 (21737\
010.25146 19,3261
010.25153 n392'
AOMIN010 11,473,1611
AOMIN010 (4$,668)
ADMIN010 19,908\
ADMJN010 (19 893.134)
TOTALSSU CUSTOMER SUPPORT
RETIREMENTS ALLOCATED@ 9.70%
(LN. 139 - LN.1721 {28 090556)
ALLOCATION TOWTX
12,108\
1904l
nm
1142,845)
(4,816)
19611
!1 928,9321
(27237931
ATMOS ENERGY CORPORATION, SHARW SERVICES INHRIM COST RECOVERY ANO RATE ADJUSTMENT REPORT
PROJECf~EPORT CY2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE 1111 CALENDAR YEAR 2016 (21
INSTALL FIVE WORKSTATIONS FOR FIVE ADDITIONAL DISPATCHERS.
INST ALL 38 DESKTOP PARTITIONS IN PLANO DISPATCH. PURCHASE AND INSTALL 65 INCH FLAT SCREEN TO DISPLAY UNACKNOWLEDGED LEAKS IN PLANO DISPATCH.
ADMIN
AOMIN
ADMIN
ADMIN
SSU RETIREMENTS· CHARLES K. VAUGHAN PER BOOK iOl 4.20% ITEMS TO FACILITATE TRANSPORTATION AND HANDS-ON TRAINING AT
010.11690 96.290 4,043 Cl<VCElllTER. ITEMS NEEDED FOR MEASUREMENT TRAINING ACTIVITIES AT CHARLES K.
010.11699 12,100 506 VAUGHN FLOW LAB IN PLANO.
010.11780 5,120 215 WELDING EQUIPMENT FOR CHARLES K. VAUGHN.
010.11795 157611 6,617 CHARLES K. VAUGHN ADDITIONAL CONSTRUCTION. REFRIGERATION FOR ATTENDEES ATIENDJNG TRAINING CLASSES AND
010.12441 1,164 49 EMPLOYEES AT CHARLES K. VAUGHN.
010.13694 21,090 885 FIVE ADDITJONAL WORKSTATIONS FOR DISPATCH IN PLANO OFFICE. 36" PORT·A·COOL FAN/3 SPEED/BELT DRIVE# PAC 2K363S ·FOR WELDING
010.13748 2,500 105 SHOP AT CHARLES K. VAUGHN. VISIX PLAYER, MEDIA PLAYER, CABLES, CONNECTORS, SUPPORT AND
010.13751 5.754 242 TRAINING OF EQUIPMENT AT CHARLES K. VAUGHN.
CKV ·CREATION OF ATMOS IOS APPLICATION FOR QUICK RESPONSE (QR) 010.13979 40749 1.711 CODES TO BE USED FOR CKV TOURS AND TRAINING,
010.14088 1.964 63 MICROPHONES FOR PRESIDENTIAL ROOM AT CHARLES K. VAUGHN. MCELROY FUSION EQUIPMENT FOR FRANKLIN, TN AND PLANO, TX -
010.14129 8616 362 CONSTRUCTJON 102 ANO 200 SERIES. CKV -TWO DIGITAL CAMERAS WITH LENS ANO FLASHES, AND ONE VIDEO
010.15290 7,967 334 CAMERA.
010.15327 7.246 304 CKV- PROACTIVE SOFTWAREfTRAINING FOR CORROSION CLASS.
010.15445 3571 150 METHANE DETECTOR FOR FLOW LAB. CKV- PURCHASE FAN POWERED METAL HOOD EXHAUST SYSTEM FOR WELDING BAYS, CONSTRUCTJON, INSTALLATION AND DEMOLITION OF
010.16680 26,316 1105 EXISITING SYSTEM.
010.16720 1.56<l 65 CKV - PURCHASE GX SOFTWARE FOR SUITE SUPPORT. CKV - PURCHASE STORYLINE SOFTWARE FOR E-LEARNING
010.17009 3230 136 DEVELOPMENT, CKV - PURCHASE LEAK DETECTION EQUIPMENT FOR LEAK SURVEY
010.17268 11,532 484 CLASSES AND DEMONSTRATIONS. CKV - PURCHASE STACKABLE NOISE PANELS FOR CUBICLES TO CUT
010.17289 2.635 111 NOISE.
010.17326 3236 136 CKV - PURCHASE STORAGE BUILDING FOR TRAINING CENTER. CKV- OFFICE RECONFIGURATION- PURCHASE FURNITURE, CABLING AND
010.17349 37,751 1,585 PERMITS. BUILD OUT OFFICE AND INSTALL FABRIC PANEL 011/lDERS IN PLANO
010.18880 24.659 1,044 DISPATCH.
010.18934 10,232 430 PURCHASE WELDING MACHINE FOR WEDLING LAB AT CKV.
010.19839 17.654 741 ITRONS FOR TRAINING METER READERS AT CKV. CKV - PURCHASE LINE LOCATORS AND AUTO CALIBRATION STATION FOR
010.22130 9296 390 TRAINING.
010.22131 2,783 117 CKV- PURCHASE ELECTROFUSJON MACHINE FOR TRAINING PURPOSES.
010.22547 21.7a7 913 INSTALL FIVE WORKSTATIONS FOR FIVE ADDITIONAL DISPATCHERS. CKV- PURCHASE OUTDOOR UNIT WITH ROLL-UP DOOR FOR CKV
010.22565 5,635 245 STORAGE.
010.23160 3.607 151 CKV- PURCHASE MIWIERX Ml WIRELESS INSTRUMENT FROM ERX. CKV - GAS CITY PHASE 1 UPGRADE. THESE ITEMS REQUIRE CONSTRUCTION AS NO OFF THE SHELF PRODUCT IS AVAILABLE FOR PURCHASE. WILL BE USED FOR THE NEW INTEGRATED LEARNING PLAN AND WILL BE USED DURING TRAINING CLASSES. CONCRETE WORK TO
010.23M7 31.525 1,324 BUILD TWO PRACTICE WALLS.
010.23386 21088 685 CKV- PURCHASE UPS BATTERY STRING REPLACEMENT.
CKV - PURCHASE ADDITIONAL IPADS FOR TECHNICAL TRAINING CLASSES 010,23411 18,899 793 AT CKV CENTER. QUOTE INLCUDES APPLE CARE AND CASES.
PURCHASE FLOW LAB ACOUSTIC ABSORBER WHICH WILL BE ATIACHED 010.23427 27.418 1,151 TO THE WALLS AND CEILING.
CKV - PURCHASE ACCESS POINT. PATCH ANTENNA AND MOUNTING FOR 010.23679 1.2!13 54 SERVICE TECHS INTEGRATED TRAINING.
010.23689 16,608 697 CKV- BUY AND INSTALL FOUR NEW WORKSTATIONS.
010.23692 11.961 502 CKV - ROOM RE-MODEL, INSTALLING CARPET, ELECTRICAL AND CABLING.
010.23761 566,842 23790 CKV- GAS CITY EXPANSION, MODEL #5 PROVERS • 1 OM DRESSER PROVER TECHNICAL TRAINING CKV
010.24423 78.072 3,278 CENTER.
010.24428 1546 65 LAPTOP FOR PROVERS TECHNICAL TRAINING FOR CKV.
010.24430 15,204 638 MUELLER VALVE CHANGER FDR TECHNICAL TRAINING AT CKV.
010.24431 6.110 257 PLCS VALVE CHANGER FOR TECHNICAL TRAINING AT CKV.
010.24433 47433 1,991 SMART CAL STATION FOR TECHNICAL TRAINING AT CKV. BATIERY PROCESSOR AND CTS INSERTS FOR FRANKLIN TECHNICAL
010.24464 3.485 146 TRAINll'lG CKV.
ssu Retirements: P•g• 4 of 5
CUSTOMERS BENEFITED LOCATION PURPOSE OF PROJECT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES EQUIPMENT ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVICES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERV!CES INFORMATION TECHNOLOGY ALL ATMOS SHARED
CUSTOMERS - MIXED SERVJCES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS· MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS- MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS- MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MJXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES INFORM~TION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS ·MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SER\llCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS· MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS -MIXED SERlllCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SER\llCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SER\llCES JNFORMATIONTECHNOLOGY
ALL ATMOS SHARED CUSTOMERS· MIXED SERVICES INFORMATION TECHNOLOGY
ALL ATMOS SHARED CUSTOMERS -MIXED SERI/ICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SER\llC/;S STRUCTURES
ALL ATMOS SHARED CUSTOMERS ·MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS -MIXED SERVlCES STRUCTURES
ALL ATMOS SHARED CUSTOMERS -MIXED SER\llCES STRUCTURES
ALL ATMOS SHARED CUSTOMERS-MIXED SERlllCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS· MIXED SER\llCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS ·MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES EQUIPMENT
ALL ATMOS SHARED CUSTOME:RS - MIXED SER\llCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SER\llCES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SER\llCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS· MIXED SER\llCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS ·MIXED SERVICES STRUCTURES
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS -MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS ·MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVICES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS - MIXED SERVlCES EQUIPMENT
ALL ATMOS SHARED CUSTOMERS· MIXED SERVICES EQUIPMENT
LINE NO,
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
238
237
23B
239
240
241
242
243
244
245
246
247
248
249
250 251
252 253
254
~ ~ ~
258 259
ALLOCATION PROJECTl'IO. COSTl11 TOWTX
010.24466 7,096 298
010.24760 17,312 727
010.25148 e,a2s 392
010.25153 7392 310
010.25270 4,786 201
010.25880 20,181 847
010,26502 34,719 1458
010.26697 332,036 13,940
010.26746 32 068 1.346
010.26780 6,593 277
010.26786 2 945 124
010.26791 3158 133
010.26823 21,326 895
010.26824 8943 375
010.26825 10,479 440
010.26826 7,061 296
010.26827 11,369 477
010.26836 7,109 298
010.2e838 6552 279
010.26839 4,831 203
010.26841 21,405 899
010.2e845 9,855 414
010.27011 39,167 1,B44
010.27133 20 649 667
0!0.27152 6,583 276
010.27176 18,655 783
01027215 6522 274
010.27222 14,654 515
010.27311 5.744 241
010.27440 12418 521
TOTAL SSU CHARLES K.VAUGHAN
RETIREMENTS ALLOCATED@ 4.20%
fLN.177 -LN. 2491 a 112,348 88 686
TOTAL SHARED SERVICES
RETIREMENTS (LN.124 + LN.135 + LN.
173 + LN.2601 164 765 3531 15496 609)
TOTAL CHANGE IN SHARED SERVICES
UTILITY PLANT {LN. 252 + ssu
ADDITIONS LN. 156} 124 789 593} /5,069,057)
NOTES:
AlMOS ENERGV COFIPOMTION, SHA.RED SERVICES ll'ITERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
PROJECT REPORT CY 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016121
RIGID PIPE 11-IREADING MACHINE FOR WEl.DING LAB TECHNICAL TRAINING CKV. GAS CITY INLET VALVE CHANGEOUT. PROJECT INCLUDES PLUMBING, EXCAVATION AND BACKFILL AND SOIL STABILIZATION.
INSTALL 38 DESKTOP PARTITIOl'IS IN PLANO DISPATCH. PURCHASE AND INSTALL 6-5 INCH FLAT SCREEN TO DISPLAY UNACKNOWLEDGED LEAKS IN PLANO DISPATCH.
CKV -REPLACE GATE MOTOR. CONSTRUCT NEW TRAINING WALL Willi FOUR FOOT SIDEWALKS AT GAS CITY. INSTALL CONCRETE PAD AND TWO LARGE STORAGE CONTAINERS AT CKV.
CKV AV UPGRADES.
CKV FURNITURE FOR TRAINING.
THREE LAPTOP COMPUTERS CKV -WILTON VISE, 10116 SOON MACHINEST FLEET BENCH VISE TO BE USED FOR CONSTRUCTION CLASSES. CKV - DEASON 2 IN-6 IN POLY PIPE PEELER USED FOR CONSTRUCTION CLASSES, CKV-VISUAL INTERACTIVE DRIVING SIMULATOR IN CAB MODEL LX 36(1) USED FOR CLASSES.
CKV -SECOR FUSION UNIT AND TWO INSERTS USED FOR CLASSES.
CKV - HEAL TH CONSULTANTS GMl3·500 WATCHER FOR CLASSES. THREE TIMBERLINE LONG HANDLE POLY SQUEEZE TOOLS FOR ADVANCED SERVICE CLASS 314-2 IN.
FOOTAGE LONG HANDLE STEEL SQUEEZE TOOL.
CKV - CENTRAL PROCESSOR MSA 340 (21 TO BE USED FOR CLASSES. CKV- MT DEASON AUTOFUSE PROCESSOR TRIPAFS00001 (2) 2,800 TO BE USED FOR CLASSES. CKV - RYCOM PIPE AND CABLE LOCATOR 8889113(2) TO BE USED FOR CLASSES. MOBILEYE UNITS INSTALLED ON VEHICLES TO ENSURE SAFE DRMNG TECHNIQUES.
CKV- PUCHASE OPERATIONS AUDIO VISUAL EQUIPMENT.
SET UP GAS CITY METER WALLS.
CKV - PURCHASE ADDITIONAL TABLES AND CHAJRS.
CKV- INSTALL CARPET IN CONFERENCE ROOM. CKV-NINE TRIMBLE JUNO HAND HELIJ MAPPING AND GIS DEVICES FOR MEASUREMENT FUNDAMENTALS CLASSES. FOUR T1'ST CAP KITS FOR CONSTRUCTION f;SSENTIALS CLASSES AND GAS MAIN TAPPING CLASSES.
CKV - BUILD N1'W CONFERENCE ROOM.
CKV- PURCHASE STAND-ALONE STORAGE CONTAINER.
CKV - DISPLA V CASES.
(1) The "COST"' CQlllmn reflects thecap]taJlzed portion arthe GOStonty.
CUSTOMERS EENEFITED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS -MIXED ALL ATMOS
CUSTOM!ORS -MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS -MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED All ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS- MIXED ALL ATMOS
CUSTOMERS - MlXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED ALL ATMOS
CUSTOMERS - MIXED
(2) The "DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR 2016" col•mn <lesonbes copilalize<l costs only.
SSU RetiremeoU
Poge 5 of5
LOCATION PURPOSE OF PROJECT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES STRUCTURES SHARED
SERVICES STRUCTURES SHARE:D
SERVICES STRUCTURES SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVlCES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES STRUCTURES SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES EQUIPMENT SHARED
SERVICES STRUCTURES SHARED
SERVICES STRUCTURES SHARED
SERVICES EQUIPMENT
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
GAS RELIABILITY INFRASTRUCTURE PROGRAM
INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
Relocation Project Report
LINE NO. PROJECT NUMBER COST
1 030.28861 3,164
2 030.29443 44
3 030.29986 1,708
4 030.30213 163
5 030.33314 1,B4B
6 030.33317 1.037
7 030.34838 1.414
a 030.35624 599
9 030.36723 5,524
10 030.36825 2,010
11 030.37751 5,517
12 030.38155 (9,269)
13 030.39045 21.757
14 030.39784 (747l
15 030.40031 9,927
16 030.40617 7,506
17 030.41861 5.573
ATMOS ENERGYCORPORATIOf'l, WEST TEXAS DIVISION INTERIM COST RECOVERY AND RA TE ADJUSTMENT REPORT
RELOCATIONS REPORT C( 2016
DESCRIPTION OF COMPLETED PROJECTS DEDICATED TO PUBLIC USE IN CALENDAR YEAR2016
RELOCATE 100 FEET OF 3 INCH AND 50 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE W1TH RAILROAD COMMISSION OF TEXAS RULEB.209
RELOCATE 310 FEET OF 4 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 [RELOCATE FAClllTIES: INSTALL215 FEET OF611.,,n AND 260 FEET OF B INCH STEEL MAIN, RETIRE 215 FEETOF6 INCHAND 260 FEET OF 8 INCH STEEL MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RELOCATE FACILITIES. INST ALL 220 FEET OF 4 INCH POLY MAIN AND RETIRE 220 FEET OF 4 INCH POLY MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209
RELOCATE 901 FEET OF6 INCH POLY MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 S RELOCATE 3 INCH LINE IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 REPLACE AND RELOCATE FACILITIES: INST ALL 208 FEET OF 2 INCH POLY MAIN AND RETIRE 208 FEET OF 3 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
RELOCATE 34 FEET OF 2 INCH STEEL MAIN IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RUl.E 8.209 REPLACE AND RELOCATE FACILITIES: INSTALL 1624 FEET OF 4 INCH POLY MAIN, 30 FEET OF 2 INCH POLY MAIN AND RETIRE 1620 FEET OF POLY MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RELOCATE 566 FEET OF 2 INCH POLY MAIN AND 2 SERVICES AND RETIRE 566 FEET OF 2 INCH POLY MAIN AND 2 SERVICES IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE AND RELOCATE FACILITIES: RETIRE22BB FEET OF 2 INCH STEEL MAIN AND INSTALL 386 FEET OF 2 INCH POLY MAIN AND 2 ASSOCIATED SERVICES DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE B.209 REPLACE AND RELOCATE FACILITIES: INSTALL 703 FEET OF 6 INCH POLY MAIN AND RETIRE 394 FEET OF 4 INCH POLY MAIN DUE TO PUBLIC IMPROVEMENT RELOCATE550 FEET OF 3 INCH STEEL MAIN DUE TO PUBLIC IMPROVEMENT IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RELOCATE 564 FEET OF 3 INCH STEEL MAIN DUE TO PUBLIC IMPROVEMENT RELOCATE29B FEET OF 2 INCH STEEL MAIN AND 1 SERVICE WITH 396 FEET OF 2 INCH POLY MAIN OUE TO PUBLIC IMPROVEMENT RELOCATE EXISTING REGULATOR STATION DUE TO PUBLIC IMPROVEMENTS IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209 RELOCATE 302 FEET OF 2 INCH POLY WITH 302 FEET OF POLY WITH ONE SERVICE DUE TO SYSTEM INTEGRITY IN ACCORDANCE WITH RAILROAD COMMISSION OF TEXAS RULE 8.209
CUSTOMERS BENEFITED
ALL· MIX
ALL· MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL-MIX
ALL-MIX
ALL- MIX
ALL· MIX
ALL-MIX
ALL-MIX
LOCATION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
030 TEXAS DIVISION
WTX Retocatf-ons ?age 1 ofl
PURPOSE OF PROJECT
PUBLIC IMPROVEMENTS
PUBLIC IMPROVEMENTS
PUBLIC IMPROVEMENTS
PUBLIC IMPROVEMENTS
PUBLIC IMPROVEMENTS
PUBLIC IMPROVEMENTS
PUBLIC IMPROVEMENTS
SYSTEM INTEGRITY
SYSTEM INTEGRITY
SYSTEM INTEGRITY
PUBLIC IMPROVEMENTS
PUBLIC IMPROVEMENTS
SYSTEM INTEGRITY SYSTEM
IMPROVEMENTS
PUBLIC IMPROVEMENTS
PUBLIC IMPROVEMENTS
SYSTEM INTEGRITY
" ......... mnH ... 1li I ;:;i · ni.r ... 1I1~1"11AL. i1•1·v1..,mA•10N
DATE PLACED IN GAS RECEIVED? RELATED TO THE AMOUNT IN COLUMN PLANT IN SERVICE YES/NO "COST"
NOT REIMBURSABLE PURSUANT TO MAY-2016 NO FRANCHISE ORDINANCE.
NOT REIMBURSA<!LE PURSUANT TO MAY-2016 NO FRANCHlSE ORDINANCE.
NOT REIMBURSABLE PURSUANT TO MAY-2016 NO FRANCHISE ORDINANCE.
THE COMPANY HAS NO EXPLICIT RIGHT OF MAY-2016 NO REIMBURSEMENT.
NOT REIMBURSABLE PURSUANT TO MAY-2016 NO FRANCHISE ORDINANCE.
NOT REIMBURSABLE PURSUANT TO MAY-::1.016 NO FRANCHISE ORDINANCE.
NOT REIMBURSABLE PURSUANT TO MAY-2016 NO FRANCHISE ORDINANCE.
THE COMPANY HAS NO EXPLICIT RIGHT OF MAY-2.016 NO REIMBURSEMENT.
THE COMPANY HAS NO EXPLICIT RIGHT OF MAY-2016 NO REIMBURSEMENT.
NOT REIMBURSABLE PURSUANT TO MAY-2.016 NO FRANCHISE ORDINANCE.
THE COMPANY HAS NO EXPLICIT RIGHT OF AUGUST· 2016 NO REIMBURSEMENT.
AUGUST - 2016 YES REIMBURSED S18,950
THE COMPANY HAS NO EXPLICIT RIGHT OF SEPTEMBER - 2016 NO REIMBURSEMENT.
AUGUST· 2016 YES REIMBURSED S17.B62
SEPTEMBER- 2016 YES REIMBURSEO 514,899.20
NOT REIMBURSABLE PURSUANT TO DECEMBER· 2016 NO FRANCHISE ORDINANCE.
THE COMPANY HAS NO EXPLICIT RIGHT OF DECEMBER· 2016 NO REIMBURSEMENT.
ATMOS ENERGY, WEST TEXAS DIVISION
2016 INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART & CHANNING
GAS RELIABILITY INFRASTRUCTURE PROGRAM
INTERIM COST RECOVERY AND RATE ADJUSTMENT REPORT
Affidavits
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION 2016 ANNUAL GAS RELIABILITY INFRASTRUCTURE PROGRAM RATE
ADJUSTMENT FOR THE IN CORPORA TED AREAS OF AMARILLO, LUBBOCK, DALHART, AND CHANNING
AFFIDAVIT OF BECKY J. PALMER
Before me, the undersigned authority, on this date personally appeared Becky J. Palmer, known to me to be the person whose name is subscribed below, and being by me first duly sworn, stated upon oath as follows:
1. "My name is Becky J. Palmer. I am President for Atmos Energy Corporation's West Texas Division. I have over 11 years of experience in the natural gas utility industry. I am fully competent to make this affidavit, and each statement of fact herein is true of my own personal knowledge.
2. Notice of the filing in this proceeding will be accomplished by bill insert for all affected Amarillo, Lubbock, Dalhart, and Channing West Texas Division customers on or before April 10, 2017. As a result, notice will be completed within 45 days of the filing date; fulfilling the requirements under Section 104.301(a) of the Texas Utilities Code."
Beck)TiB r ~
SWORN TO AND SUBSCRIBED before me on this the lk_ day of February 2017.
~'''~V~~''" GISELLE R HEROY ~"'"'·""\!!~ • fT ff(:..A.::·~~Notarv·Pubh~, State o .exas \~\"5Q.i Comm. Expires 09-01-2020
~,,%flf,\\\.s' Notary ID 130804'84-~
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION
2016 ANNUAL GAS RELIABILITY INFRASTRUCTURE PROGRAM RA TE ADJUSTMENT FOR THE INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART, AND CHANNING
AFFIDAVIT OF BECKY J. PALMER
Before me, the undersigned authority, on this date personally appeared Becky J. Palmer, known to me to be the person whose name is subscribed below, and being by me first duly sworn, stated upon oath as follows:
1. "My name is Becky J. Palmer. I am President for Atmos Energy Corporation's West Texas Division. I have over 11 years of experience in the natural gas utility industry. I am fully competent to make this affidavit, and each statement of fact herein is true of my own personal knowledge.
2. In every instance in which Atmos Energy Corporation, West Texas Division is eligible for reimbursement of relocation expenses from a governmental entity, it has actively sought reimbursement. In every instance in which Atmos Energy Corporation, West Texas Division is eligible for reimbursement of relocation expenses from a non-governmental entity, it has actively sought reimbursement.
3. To the best of my knowledge, as of the date of this filing, all reimbursements received or invoiced as of December 31, 2016 for relocation projects included in this filing are reflected in the amounts in the filing. If any reimbursement amounts are received or invoiced after December 31, 2016 for relocation projects included in this filing, such amounts will be. booked to the respective plant account of the utility and accounted for in the next applicable filing."
Bee~~ SWORN TO AND SUBSCRIBED before me on this the {~fk day of February 2017.
ATMOS ENERGY CORPORATION, WEST TEXAS DIVISION 2016 ANNUAL GAS RELIABILITY INFRASTRUCTURE PROGRAM RATE
ADJUSTMENT FOR THE INCORPORATED AREAS OF AMARILLO, LUBBOCK, DALHART, AND CHANNING
AFFIDAVIT OF BARBARA W. MYERS
Before me, the 1mdersigned authority, on this date personally appeared Barbara W. Myers, known to me to be the person whose name is subscribed below, and being by me first duly sworn, stated upon oath as follows:
1. "My name is Barbara W. Myers. I am Manager, Rates & Regulatory Affairs for Atmos Energy Corporation (the "Company"). I joined the Company on October 1, 2004, when Atmos Energy Corporation acquired the assets of TXU Gas Company. Prior to October 1, 2004, I was Regulatory Accounting Manager and Gas Accounting Manager for TXU Gas Company. I am a certified public accountant in the State of Texas and I have over 30 years of experience in accounting related to natural gas utilities. I am fully competent to make this affidavit, and each statement of fact herein is true of my own personal knowledge.
2. The Company keeps its books and records in accordance with the Rules of the Railroad Commission of Texas, and in accordance with the Federal Energy Regulatory Commission's (FERC) Uniform System of Accounts (USOA) prescribed for Natural Gas Companies subject to the Provisions of the Natural Gas Act (as amended from time to time) (FERC USOA) for all operating and reporting purposes, unless authorized to depart from such system of accounts by the applicable regulatory authorities.
3. I have reviewed the schedules filed by the Company in this proceeding. These schedules are accurate summaries. of the books and records for the period between January 1, 2016 and December 31, 2016."
-+h SWORN TO AND SUBSCRIBED before me on this the j_k_ day of February, 2017.
,.:.''''~W11~ GISELLE R HEROY *!\t.!'d .. .lle.~ ~?t:...A,;:~~-: Notary ·Public, State of Texas
\!;J.···"'54~ff Comm. Expires 09-01-2020 ~,zsf.,,,,, N~_t1J.ry m 1 aoao4s4-~