Aqua Rite ProElectronic Chlorine Generator
Owner's Manual
AQR15-PROAQR15-PRO-SD
092544 RevA
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
IMPORTANT SAFETY INSTRUCTIONS
• READANDFOLLOWALLINSTRUCTIONS
• WARNING–Toreducetheriskofinjury,donotpermitchildrentousethisproductunlesstheyarecloselysupervisedatalltimes.
• Awirebondinglugisprovidedonthelowerexternalsurface(twoforCanadianmodels)ofthisunittoconnectaminimum8AWG(8.4mm2)solidcopperconductorbetweenthisunitandanymetalequipment,metalenclosuresofelectricalequipment,metalwaterpipe,orconduitwithin5feet(1.5m)tyingtheunittothelocalbondinggrid.
• UseCopperConductorsOnly
• DisconnectallACpowerduringinstallation.
• Agreencoloredterminalmarked“Ground”islocatedinsidethewiringcompartment.Toreducetheriskofelectricshock,thisterminalmustbeconnectedtothegroundingmeansprovidedintheelectricsupplyservicepanelwithacontinuouscopperwireequivalentinsizetothecircuitconductorssupplyingtheequipment.
• Allfield installedmetalcomponentssuchasrails, ladders,drains,orothersimilarhardwarewithin3metersofthepool,spaorhottubshallbebondedtotheequipmentgroundingbuswithcopperconductorsnotsmallerthan8AWGUS/6AWGCanada.
• NOTICETOUSERS:Thiscontrolproductistobeusedonlyinaccordancewiththedirectionsofthislabel.ItisanoffenseunderthePestControlProductsActtouseacontrolproductunderunsafeconditions.
• SAVE THESE INSTRUCTIONS
1
USE ONLY HAYWARD GENUINE REPLACEMENT PARTSUSE ONLY HAYWARD GENUINE REPLACEMENT PARTSUSE ONLY HAYWARD GENUINE REPLACEMENT PARTS
OperationTheAquaRiteProisanautomaticchlorinegenerationsystemforpoolorspasanitization.Theoperationrequiresalowconcentrationofsalt(sodiumchloride)inthepoolwater.Theselevelsarelowenoughthatitnormallywillnotbetasted.TheAquaRiteProautomaticallysanitizesyourpoolbyconvertingthesaltintofreechlorinewhichkillsbacteriaandalgaeinthepool.Chlorinewillrevertbacktosodiumchlorideafterkillingbacteria.Thesereactionswillcontinuouslyrecyclevirtuallyeliminatingtheneedtoaddsanitizingchemicalstoyourpool.Theonlytimeyoumayneedtoaddmoresalttothepooliswhenwaterisreplenishedduetobackwashing,draining,orsplashing(notevaporation).
TheAquaRiteProisdesignedtohandlethepurificationneedsofmostresidentialswimmingpoolsupto40,000gallons(150,000liters),ortheneedsofmostcommercialpoolsupto25,000gal-lons(95,000liters).Checklocalcodesforotherrestrictions.Theactualamountofchlorinationrequiredtoproperlysanitizeapoolvariesduetobatherload,rainfall,temperature,andthepool'scleanliness.
TheAquaRiteProisavailableintwomodels:
AQR15-PRO-forpoolsupto40,000gallonsAQR15-PRO-SD-forpoolsupto40,000gallons,includesSense&Dispense
Note that the installation and mounting requirements are the same for all models.
TheAquaRiteProcanbeusedwiththeHaywardAQL-CHEM(includedwithAQR15-PRO-SD)toprovideafullyintegratedchemistrysolutionforyourpool.WiththeAQL-CHEMinstalled,theAquaRiteProsensesthepool'sORPandpHlevelsandautomaticallygeneratesthecorrectamountofchlorinetokeepyourpoolproperlysanitized.TheAquaRiteProcanalsocontrolpHbyintro-ducingacidorCO
2intothepoolusinganAQL-CHEM2(120V),AQL-CHEM2-240(240V)orother
dispensingdevicerequiring120VACor240VACon/offcontrol.TheAquaRiteProandAQL-CHEMproductsoffertheuseracompleteautomatedsystemcontrollingbothsanitizationandpHbalance.
NOTE: Hayward does not recommend using the AquaRite Pro to generate bromine.
NOTE:Beforeinstallingthisproductaspartofasalinewaterpurificationsysteminapoolorspausingnaturalstoneforcopingorforimmediatelyadjacentpatios/decking,aqualifiedstoneinstal-lationspecialistshouldbeconsultedregardingtheappropriatetype,installation,sealant(ifany)andmaintenanceofstoneusedaroundasalinepoolwithelectronicchlorinegeneratorinyourparticularlocationandcircumstances.
NOTE:Theuseofdryacid(sodiumbisulfate)toadjustpoolpHisdiscouragedespeciallyinaridre-gionswherepoolwaterissubjecttoexcessiveevaporationandisnotcommonlydilutedwithfreshwater.Dryacidcancauseabuildupofby-productsthatcandamageyourchlorinatorcell.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
2
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
WaterChemistryThetablebelowsummarizesthelevelsthatarerecommendedbyTheAssociationofPoolandSpaProfessionals(APSP).TheonlyspecialrequirementsfortheAquaRiteProarethesaltlevelandstabilizer.Itisimportanttomaintaintheselevelsinordertopreventcorrosionorscalingandtoensuremaximumenjoymentofthepool.Testyourwaterperiodically.YourauthorizedAquaRiteProdealerormostpoolstorescanprovideyouwiththechemicalsandprocedurestoadjustthewaterchemistry.BesuretotellthepoolstorethatyouareusinganAquaRiteProchlorinegenera-tor.
SaturationindexThesaturationindex(Si)relatestothecalciumandalkalinityinthewaterandisanindicatorofthepoolwater"balance".YourwaterisproperlybalancediftheSiis0±.2.IftheSiisbelow-0.2,thewateriscorrosiveandplasterpoolwallswillbedissolvedintothewater.IftheSiisabove+0.2,scalingandstainingwilloccur.Usethechartbelowtodeterminethesaturationindex.
ºC ºF Ti CalcuimHardness Ci Total
Alkalinity Ai
53
60
66
76
84
94
103
12
16
19
24
29
34
39
.3
.4
.5
.6
.7
.8
.9How to use: Measure pool pH, temperature, calcium hardness,and total alkalinity. Use the chart above to determine Ti, Ci,andAi from your measurements. Insert values of pH, Ti, Ci and Aiinto the above equation. If Si equals .2 or more, scaling and staining may occur. If Si equals -.2 or less corrosion or irritationmay occur.
Si = pH + Ti + Ci + Ai - 12.1
-.2 0 .2CORROSIVE SCALING
75 75100 100125 125150 150200 200250 250300 300400 400600 600800 800
1.5 1.91.6 2.01.7 2.11.8 2.21.9 2.32.0 2.42.1 2.52.2 2.62.4 2.82.5 2.9
OK
3
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
SaltLevelUsethechartonpage5todeterminehowmuchsaltinpoundsor(Kgs)needtobeaddedtoreachtherecommendedlevels.Beawarethattheremayalreadybesaltinyourpoolfromprolongeduseofchlorine.Testyourpool,thenaddthecorrectamount.Usetheequationsbelow(measurementsareinfeet/gallonsandmeters/liters)ifpoolsizeisunknown.
Theidealsaltlevelisbetween2700-3400ppm(partspermillion)with3200ppmbeingoptimal.Ifthelevelislow,determinethenumberofgallonsinthepoolandaddsaltaccordingtothechartonpage5.AlowsaltlevelwillreducetheefficiencyoftheAquaRiteProandresultinlowchlorinepro-duction.AhighsaltlevelcancausetheAquaRiteProtoshutdownandmaybegintogiveasaltytastetoyourpool(generally,thesaltwillbegintobetastedatalevelofabout3500-4000ppm).Thesaltinyourpool/spaisconstantlyrecycledandthelossofsaltthroughouttheswimmingseasonshouldbesmall.Thislossisdueprimarilytotheadditionofwaterbecauseofsplashing,backwashing,ordraining(becauseofrain).Saltisnotlostduetoevaporation. TypeofSalttoUseItisimportanttouseonlysodiumchloride(NaCl)saltthatisgreaterthan99%pure.Thisiscommonfoodqualityorwatersoftenersaltandisusuallyavailablein40-80lb.bagslabeled"CoarseSolarSalt".Itisalsoacceptabletousewaterconditioningsaltpellets,however,itwilltakelongerforthemtodissolve.Donotuserocksalt,saltwithyellowprussiateofsoda,saltwithanti-cakingadditives,oriodizedsalt.
HowtoAddorRemoveSaltFornewplasterpools,wait10-14daysbeforeaddingsalttoallowtheplastertocure.Turnthecir-culatingpumponandaddsaltdirectlyintothepool.Brushthesaltaroundtospeedupthedissolvingprocess--donotallowsalttopileuponthebottomofthepool.Runthefilterpumpfor24hourswiththesuctioncomingfromthemaindrain(usepoolvacifthereisnomaindrain)toallowthesalttoevenlydispersethroughoutthepool.Thesaltdisplaymaytake24hourstorespondtothechangeinsaltconcentration.
Theonlywaytolowerthesaltconcentrationistopartiallydrainthepoolandrefillwithfreshwater.
Foroutdoorpools,alwayscheckstabilizer(cyanuricacid),whencheckingsalt.Theselevelswillmostlikelydeclinetogether.Usethechartonpage6todeterminehowmuchstabilizermustbeaddedtoraisethelevelto40ppm.
Gallons Liters(pool size in feet) (pool size in meters)
Rectangular
Round
Oval
Diameter x Diameter x Average Depth x 5.9
Length x Width x Average Depth x 6.7
Length x Width x Average Depth x 7.5
Diameter x Diameter x Average Depth x 785
Length x Width x Average Depth x 893
Length x Width x Average Depth x 1000
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
Gal
lons
and
(Lite
rs) o
f Poo
l/Spa
wat
er12
,000
14,0
0016
,000
18,0
0020
,000
22,0
0032
,000
24,0
0034
,000
26,0
0036
,000
28,0
0038
,000
30,0
0040
,000
Cur
rent
sal
t le
vel
(450
00)
(52,
500)
(60,
000)
(67,
500)
(75,
000)
(82,
500)
(120
,000
)(9
0,00
0)(1
27,5
00)
(97,
500)
(135
,000
)(1
05,0
00)
(142
,500
)(1
12,5
00)
(150
,000
)pp
m 032
0
(145
)37
3
(170
)42
7
(194
)48
0
(218
)(2
42)
587
85
4
(267
)(3
88)
640
90
7
(291
)(4
12)
693
96
0
(315
)(4
36)
747
(3
39)
(460
)80
0
1067
(364
)(4
84)
200
300
(1
36)
350
(1
59)
400
(1
82)
450
(2
05)
500
(2
27)
550
80
0
(250
)(3
63)
600
85
0
(273
)(3
85)
650
90
0
(295
)(4
08)
700
95
0 (3
18)
(430
)75
0
1000
(3
41)
(453
)
400
280
(1
27)
327
(1
48)
373
(1
70)
420
(1
91)
467
(2
12)
513
74
7
(233
) (3
39)
560
79
3
(255
)(3
60)
607
84
0
(276
)(3
82)
653
88
7(2
97)
(403
)70
0
933
(318
)(4
24)
600
260
(1
18)
303
(1
38)
347
(1
58)
390
(1
77)
433
(1
97)
477
69
3
(217
)(3
17)
520
73
7
(236
)(3
37)
563
78
0
(256
)(3
58)
607
82
3(2
76)
(378
)65
0
867
(297
)(3
98)
800
240
(1
09)
280
(1
27)
320
(1
45)
360
(1
64)
400
(1
82)
440
64
0
(200
)(2
91)
480
68
0
(218
)(3
10)
520
72
0
(236
)(3
28)
560
76
0(2
55)
(346
)60
0
800
(2
73)
(364
)
1000
220
(1
00)
257
(1
17)
293
(1
33)
330
(1
50)
367
(1
67)
403
58
7
(183
)(2
67)
440
62
3
(200
)(2
83)
477
66
0(2
17)
(300
)51
3
69
7(2
33)
(317
)55
0
733
(250
)(3
33)
1200
200
(9
1)23
3
(106
)26
7
(121
)30
0
(136
)33
3
(152
)36
7
533
(1
67)
(243
)40
0
567
(1
82)
(258
)43
3
600
(1
97)
(274
)46
7
63
3(2
12)
(289
)50
0
667
(227
)(3
04)
1400
180
(8
2)21
0
(95)
240
(1
09)
270
(1
23)
300
(1
36)
330
48
0 (1
50)
(218
)36
0
510
(1
64)
(232
)39
0
540
(1
77)
(246
)42
0
57
0(1
91)
(259
)45
0
600
(205
)(2
63)
1600
160
(73)
187
(8
5)21
3
(97)
240
(1
09)
267
(1
21)
293
42
7
(133
)(1
95)
320
45
3
(145
)(2
07)
347
48
0
(158
)(2
19)
373
50
7 (1
70)
(231
)40
0
533
(182
)(2
43)
1800
140
(64)
163
(74)
187
(85)
210
(9
5)23
3
(106
)25
7
373
(1
17)
(169
)28
0
397
(1
27)
(180
)30
3
420
(1
38)
(190
)32
7
44
3 (1
48)
(201
)35
0
46
7(1
59)
(211
)
2000
120
100
80
60
20
40
(55)
(45)
(36)
(27)
(9)
(18)
140
117
23
47
(64)
(53)
(11)
(21)
160
133
27
53
(73)
(61)
(12)
(24)
180
150
30
60
(82)
(68)
(14)
(27)
200
167
33
67
(91)
(76)
(15)
(30)
220
320
183
267
37
53
73
10
7
(100
)(1
45)
(83)
(121
)
(17)
(24)
(33)
(48)
240
340
200
283
40
57
80
11
3
(109
)(1
54)
(91)
(129
)
(18)
(26)
(36)
(51)
260
36
0
217
30
0
43
60
87
120
(118
)(1
63)
(98)
(137
)
(20)
(27)
(39)
(54)
280
380
233
317
47
63
93
12
7
(127
)(1
72)
(106
)(1
44)
(21)
(29)
(42)
(57)
300
400
250
333
50
67
100
133
(136
)(1
81)
(114
)(1
52)
(23)
(30)
(45)
(60)
(32)
80
(3
6)90
(41)
100
(45)
110
160
(50)
(73)
120
170
(5
5)(7
7)13
0
180
(5
9)(8
1)14
0
19
0(6
4)(8
6)15
0
20
0(6
8)(9
0)
93
(4
2)10
7
(4
8)12
0
(5
5)13
3
(6
1)14
7
21
3
(6
7)(9
8)16
0
22
7
(73)
(104
)17
3
240
(7
9)(1
10)
187
253
(85)
(117
)20
0
26
7(9
1)(1
23)
2200
3000
2800
2400
3200
Idea
lId
eal
Idea
lId
eal
Idea
lId
eal
Idea
lId
eal
Idea
lId
eal
Idea
lId
eal
Idea
lId
eal
Idea
l
2600
3400
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
POU
ND
S an
d (K
g) O
F SA
LT N
EED
ED F
OR
320
0 PP
M
3600
+D
ilute
Dilu
teD
ilute
Dilu
teD
ilute
Dilu
teD
ilute
Dilu
teD
ilute
Dilu
teD
ilute
Dilu
teD
ilute
Dilu
teD
ilute
10,0
00 8
,000
(37,
500)
213
26
7
(97)
(121
)
200
25
0
(91)
(114
)
187
23
3
(85)
(106
)
173
21
7
(79)
(98)
160
20
0
(73)
(91)
147
18
3
(67)
(83)
133
16
7
(61)
(76)
120
15
0
(55)
(68)
107
133
(48)
(61)
93
11
7
(4
2)(5
3)
80
10
0
67
83
53
67
40
50
13
17
27
33
(36)
(45)
(30)
(38)
(24)
(30)
(18)
(23)
(6)
(8)
(12)
(15)
Idea
lId
eal
Dilu
teD
ilute
(30,
000)
5
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
6
ControlsKeypadButtonsRUN/STOP:TheAquaRiteProwilltogglebackandforthbetweenRUNandSTOPwitheachpushoftheRUN/STOPbutton.
RUN:WheninRUNmode,theAquaRiteProwillproducechlorineaccordingtothedesiredoutput%orORPsetting(whenAQL-CHEMisused)fortheentirefiltering/pumpingcycle.TheAquaRiteProcanonlyproducechlorinewhenRUNisselectedandthefilterpumpisrunning.
STOP: WheninSTOPmode,theAquaRiteProispreventedfromenergizingtheelectrolyticcell.Inthispositionthereisnochlorinegeneration.NOTE:ToserviceanyofthepoolequipmentortheAquaRitePro,thepowermustbeturnedoffatthecircuitbreaker. SUPER CHLORINATE: (ifoptionalAQL-CHEMsensingisNOTused)Whenyouhaveanabnormallyhighbatherload,alargeamountofrain,acloudywatercondition,oranyotherconditionwhichneedsalargeamountofpurificationtobeintroduced,SUPERCHLORINATEshouldbeselected.Thiselectronically“superchlorinates”(shocks)thewaterforauserselectableperiodof1-96hours(filterpumpmustbeonduringthistime)oruntilthepowerhasbeenturnedoff,whichevercomesfirst.TheAquaRiteProwillautomaticallyrevertbacktothepreviousdesiredoutput%set-tingattheendofthesuperchlorinateperiod.
INFO: PushtheINFObuttontoentertheInformationMenu(seeInformationMenu).
SETTINGS:PushtheSETTINGSbuttontoentertheSettingsMenu(seeSettingsMenu).
CURSORS (+, -, <, >): Usethesebuttonstoscrollthroughsubmenus,makeselectionsandadjustvalues.
IndicatorLED'sRUN/STOP: Whenilluminated,theAquaRiteProisinautomaticmodeandwillproducechlorinebasedonthedesiredoutput%orORPsetting(whenAQL-CHEMisused).WhentheLEDisoff,theAquaRiteProhasbeenmanuallyturnedoff.ItwillnotproducechlorineuntilRUNhasbeenselected.
SUPER CHLORINATE: Whenilluminated,theSuperChlorinatefeatureisactive.
CHECK SYSTEM:WhenCheckSystemisilluminated,anerrorhasoccurredthatrequiresatten-tion.RefertotheTroubleshootingsectionofthismanualforpossibleerrorsandsolutions.
7
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
InformationMenuTheInformationMenudisplaysvaluablesystemandpoolinformation.TheAquaRiteProwilldefaulttodisplayingaportionoftheInformationMenuwhennobuttonshavebeenpushedfor2minutes.Theunitwillautomaticallyscrollthroughseveralstatusdisplays.ToaccessalloftheInformationMenuitems,pushtheINFObuttononthefrontpanel.Advancethroughthevariousmenuitemsusingthe"<"or">"buttons.AlistoftheInformationMenuitemsisshownbelow.
TheAquaRiteProdesiredoutput%isshownhere.IfSuperChlorinateisactive,thedisplaywillshowthetimeremaininguntiltheAquaRiteProwillreturntothedesiredoutput%.ThismenuisdisabledifanAQL-CHEMisusedandORPAutoSensingisenabled(seeAQL-CHEMmanual).
Thisdisplaywillbeshownonlyifchemicalsensingisenabled.ThisdisplayshowsbothpHandORPlevels/statuswhenchemistrysensingisenabledviatheChemistryCon-figurationWizard(requirestheuseofAQL-CHEMSensingKit).TheAquaRiteProwillrefertotheselevelstodeterminehowmuchchlorinetogenerate(ORP)andhowmuchCO
2oracidtodispense(pH).RefertotheAQL-CHEMmanualforspecificinformation
abouttheselevelsaswellastherecommendedranges.
+/-23.45Visthevoltageappliedtothechlorinatorcell+/-6.75Aisthecurrent(amps)throughthecell84ºFisthewatertemperatureatthecell3200PPMisthe“instant”saltlevelatthistime
Forthechlorinatortobeoperating,severalconditionsmustexist:thefilterpumpmustberunning,theflowswitchmustbedetectingflow,thechlorinatorsettingmustbesetgreaterthan0%,thewatertemperatureatthecellmustbebetween50ºFand140ºF,andthesaltlevelmustbewithintheoperatingrange.Ifanyoftheseconditionsarenotmet,thechlorinatordiagnosticdisplaywilltellyouthereason.It’spossibletohavemorethanonereason,inwhichcaseafteryourectifywhatwasdisplayedthefirsttime,aseconddisplaywillappear.
Ifthecurrent(amps)displayis0.00A,thenthechlorinatorisoperatingnormallybutisintheoffpartofitsnormaloperatingcycle.Simplypresseitherthe“+”or“-“keytostartanewcycle.
TheAquaRiteProperiodicallyreversesthepolarityofthevoltageappliedtothecellinordertoautomaticallycleanoffanycalciumdepositsthatmayhavebuiltuponthecell.Itisimportantthatyoucheckthechlorinatoroperationinbothpolarities.Todothis,presseitherthe“+”or“-“buttonsandthechlorinatorwillturnoff,waitfor15secondsandthenturnonintheoppositepolarity.
Chlorinator50%
No functionMove to previous/next menu item
Super Chlorinate22:15 remaining
No functionMove to previous/next menu item
if ORP Auto Sensing is not used
pH 7.5 (On)ORP 700 mV (On)
No functionMove to previous/next menu item
if AQL-CHEM is used
Set Day and TimeWednesday 10:37P Move to previous/next menu item+23.45 +6.75A84°F 3200PPM
Press to switch chlorinator operation to opposite polarity (15 second delay)
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
8
Thisistheaverage"SaltLevel"inthepool.Thisvalueiscalculatedovertimeandminimizestheeffectsofspikesordipsthatmaynaturallyoccur.
The“InstantSalt”iscalculatedbasedonthevoltage,current(amps),andwatertemperatureatthecellatthatinstant.Thereareanumberofreasonswhyinstantandaveragesaltreadingsmaydiffer.Someoftheseincludesalthavingjustbeenaddedtothepoolandnotyetthoroughlymixed,calciumbuilduponthecell,andcellaging.
Pressthe"+"buttontoentertheinstantsaltvalueintotheaveragesaltlevel.Theaveragesaltlevelwillusethisnewvalueforitscalculations.
Thecurrentstatusoftheflowswitchisdisplayed.Thereisashortdelaywhentransi-tioningfromflowtono-flowandalongerdelayonthetransitionfromno-flowtoflow.Thedelaytimeisdisplayed.
Availabledisplaysdependonconfiguration.Thesedisplaysshowthesoftwarerevisionsofvariouscomponents.
Foroptimumoperation,youwillneedtoinspecttheAquaRiteProchlorinatorcellapproximatelyevery3monthsandcleanthecellifnecessary.TheAquaRiteProwillautomaticallyremindyouanddisplay“InspectCell,hold+toreset”aspartoftherotatingInformationMenu.Cleanthecellandthenpressthe“+”buttonduringthe“InspectCell”displaytoresetthetimer.
Salt Level3200 PPM
No functionMove to previous/next menu item
Instant Salt3200 PPM (+=save) Move to previous/next menu item
Press to load the “Instant Salt” into the averaged salt display
Flow SwitchFlow
No functionMove to previous/next menu item
Main SoftwareRevision 1.10
Display SoftwareRevision 0.18
No function
No function
Move to previous/next menu item
Move to previous/next menu item
Chemistry SenseSoftware r1.28
No functionMove to previous/next menu item
Inspect Cellhold + to reset
Press to resetMove to previous/next menu item
9
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
RefertotheTroubleshootingsectionforinformationabouterrorconditionsandpossiblecauses.
SettingsMenuTheSettingsMenuisusedtoconfiguretheAquaRiteProandadjustvarioussettings.AccessthismenubypushingtheSettingsMenubutton.Refertotheinformationbelowwhensettingsystemoperatingparameters.
Body of Water TypeSelectPoolorSpa."Pool"shouldbeselectedforbodiesofwaterover1000gallons.TheAquaRitePro will adjustitsoperationaccordingtothisselection. DisplayAllowsforthedisplayofsalt(default)ormineralvalues.
Cell Type SelectionSelectionsare:T-CELL-3,T-CELL-5,T-CELL-9andT-CELL-15(default).TheAQR15-PROandAQR15-PRO-SDincludeaT-CELL-15cell.Notethattheunitwillnotfunctionproperlyifthewrongcellisselected.
"T-CELL-3"=T-CELL-3,GLX-CELL-3-W"T-CELL-5"=GLX-CELL-5,GLX-CELL-5-W"T-CELL-9"=T-CELL-9,GLX-CELL-9-W"T-CELL-15"=T-CELL-15,GLX-CELL-15-W
RequiresuseoftheoptionalAQL-CHEMSensingKit.FollowingthestepsoftheChemis-tryConfig.WizardwillsetuptheAQL-CHEMtosenseORPandpHlevels.TheAquaRiteProwillgeneratethecorrectamountofchlorinetoproperlysanitizethepoolbasedontheAQL-CHEMsensingfunction.RefertotheAQL-CHEMmanualformoredetailedinformation.
Check SystemLow Salt
Function depends on displayed menu itemMove to next Check System condition orprevious/next menu item
Cell TypeT-CELL-15
Toggle between available cell typesMove to previous/next menu item
Move to next menu itemChlorinator
Enabled
DisplaySalt
Chlor. Config.+ to view/change
Toggle between Salt (default) and Minerals
Toggle between Pool and Spa
Move to next menu item
Move to previous/next menu itemPush to access Chlorinator option
Cell TypeT-CELL-15
Body of Water TypePools
DisplaySalt
Chlor. Config.+ to view/change
Chemistry Config.Wizard + to enter
Sensing SystemEnabled
Push to access Chemistry Config. Wizard
Toggle between Enabled and Disabled (default)
Move to previous/next menu item
Move to next menu item
if AQL-CHEM is used
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
10
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Thedesiredoutput%isusedtocontroltheamountofchlorinetheAquaRiteProgen-erates.Raisethissettingtoincreasechlorinelevelandlowerittodecreasechlorinelevel.IfanAQL-CHEMisbeingusedandORPAutoSensingisenabled(seeAQL-CHEMmanual),theAquaRiteProwilloverridethedesiredchlorinatoroutput%settingandgeneratechlorinebasedonthepool'sORPlevel.
UsetheSuperChlorinatefeaturewhenthereisanunusuallyhighbatherload,alargeamountofrain,acloudywatercondition,oranyotherconditionthatrequiresalargeamountofchlorinetobeintroducedtothepool.NotethatthefilterpumpmustberunningfortheentiretimeduringtheSuperChlorinateperiod.Settheactualtimebasedonthesizeofthepool;largerpoolsrequiremorehours,smallerpoolsrequireless.
UsethisWizardtocalibratetheoptionalAQL-CHEM’spHprobe.ThisrequiresamanualpHtestofthepoolwaterusingadependableredphenoltestkit(seeAQL-CHEMmanual).
UsethisWizardtocleantheoptionalAQL-CHEM’sORPandpHprobes.Theprobesmustbecleanandfreefromoil,chemicaldepositsandcontaminationtofunc-tionproperly.Slowresponse,increasedneedtocalibrate,andinconsistentreadingsareindicationsthattheprobesneedtobecleaned(seeAQL-CHEMmanual).
TheAquaRiteProcandisplaytemperatureandunitsinMetric(ºCandg/L)orEnglish(ºFandPPM).Makethedesiredselectionhere.
Chlorinator50%
Adjust the desired output % for the poolMove to previous/next menu item
if ORP Auto Sensing is not used
Super Chlorinate22 hours
Adjust Super Chlorinate period (1-96 hours)Move to previous/next menu item
if ORP Auto Sensing is not used
if AQL-CHEM is usedClean Probe Wizard
+ to enterPush to access Clean Probe WizardMove to previous/next menu item
pH CalibrationWizard + to enter
Push to access pH Calibration WizardMove to previous/next menu item
if AQL-CHEM is used
UnitsMetric Move to previous/next menu item
Toggle between Metric and English
11
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Thisfunctioncontrolsthebacklightonthedisplay.Selectbetween"AlwaysOn"and"Onfor60seconds".If“Onfor60seconds”optionisselected,thentheback-lightwillautomaticallyturnoff60secondsafterthelastkeyispressedandwillstayoffuntilnexttimeakeyispressed.
When“Enabled”,thekeypadwillbeepeverytimeakeyispressed.Ifthisaudibleindicationisnotdesired,select“Disabled”.
Usethisfunctiontoeraseallprevioussystemconfigurationandresetallconfigura-tionparametersbacktothefactorydefaultvalues.ThisfunctionisNOTreversible--becareful
OperationAssumingthatthewaterchemicallevelsareintherecommendedrange,therearethreefac-torsthatyoucancontrolwhichdirectlycontributetotheamountofchlorinetheAquaRiteProwillgenerate:
1. filterruntimeeachday(hours)2. thedesiredoutput%settingorORPsetting(whenusingAQL-CHEM)3. theamountofsaltinthepool Thefilterpumptimershouldbesetsothatentirevolumeofpoolwaterpassesthroughthefiltereachday.Forpoolswithhighchlorinedemand,thetimermayhavetobesetlongertogenerateenoughchlorine.
IfAQL-CHEMsensingisNOTused:Tofindtheoptimumdesiredoutput%setting,startatapproximately50%.Testthechlorineleveleveryfewdaysandadjustthesettingupordownaccordingly.Itusuallytakes2-3adjustmentstofindtheidealsettingforyourpool/spaandafterthat,itshouldonlytakeminor,infrequentadjustments.Becausethechlorinedemandofthepoolincreaseswithtemperature,mostpeoplefindtheyhavetoadjustthedesiredoutputupatthepeakofthesummeranddownduringthecolderperiods.
NOTE:Aftertheidealsettinghasbeenfound,youmayneedtoraisethesettingwhenthepoolwatertemperatureincreasessignificantly,whenthereishigherthannormalbatherloadorwhenyourchlorinatorcellages.Youmayneedtolowerthesettingwhenthepoolwatertemperaturedecreasessignificantlyortherearelongperiodsofinactivity.
Display LightOn for 60 sec
Toggle between Always On and On for 60 sec.Move to previous/next menu item
BeeperEnabled
Toggle between Enabled (default) and Disabled BeeperMove to previous/next menu item
Reset Config. toDefault Press +
Are you sure?+ to proceed
Config. resetConfirmed
Initiate reset of all configuration parameters
Reset all configuration parameters
Move to previous/next menu item (config. not reset)
Move to previous/next menu item (config. not reset)
Move to previous/next settings menu item
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
12
TheAquaRiteProautomaticallystopsgeneratingwhenthepoolwatertemperaturesdropsbelow50ºF.Thisisusuallynotaproblembecausebacteriaandalgaestopgrowingatthistemperature.YoucanoverridethislowtemperaturecutoffbyusingtheSuperChlorinatefunctionforaday.Preventoverchlorinationduringcoldweather:Checkchlorinelevelsperiodically.Mostpoolsrequirelesschlorineduringcoldweatherandthedesiredoutput%settingshouldbeloweredaccordingly. MaintainingtheAquaRiteProSystemTomaintainmaximumperformance,itisrecommendedthatyouopenandvisuallyinspectthecellevery3monthsoraftercleaningyourfilter.TheAquaRiteProwillremindyoutodothisbydisplay-ingthemessage“Inspect/CleanCell”afterapproximately500hoursofoperation.
TheAquaRiteProelectrolyticcellhasaselfcleaningfeatureincorporatedintotheelectroniccon-trol’slogic.Inmostcasesthisselfcleaningactionwillkeepthecellworkingatoptimumefficiency.Inareaswherewaterishard(highmineralcontent)andinpoolswherethewaterchemistryhasbeenallowedtoget"outofbalance",thecellmayrequireperiodiccleaning.
ServicingandCleaningtheAquaRiteProCellTurnoffpowertotheAquaRiteProbeforeremovingtheelectrolyticcell.Onceremoved,lookinsidethecellandinspectforscaleformation(lightcoloredcrustyorflakydeposits)ontheplatesandforanydebriswhichhaspassedthroughthefilterandcaughtontheplates.Ifnodepositsarevisible,reinstall.Ifdepositsareseen,useahighpressuregardenhoseandtrytoflushthescaleoff.Ifthisisnotsuccessful,useaplasticorwoodtool(donotusemetalasthiswillscratchthecoatingofftheplates)andscrapedepositsoffofplates.Notethatabuilduponthecellindicatesthatthereisanunusuallyhighcalciumlevelinthepool(oldpoolwaterisusuallythecause).Ifthisisnotcorrected,youmaytohavetoperiodicallycleanthecell.Thesimplestwaytoavoidthisistobringthepoolchemistrytotherecommendedlevelsasspecified.
Mild Acid Washing:Useonlyinseverecaseswhereflushingandscrapingwillnotremovethemajorityofdeposits.Toacidwash,turnoffpowertoAquaRitePro.Removecellfrompiping.Inacleanplasticcontainer,mixa4:1solutionofwatertomuriaticacid(onegallonofwatertoonequartofmuriaticacid).ALWAYSADDACIDTOWATER-NEVERADDWATERTOACID.Besuretowearrubberglovesandappropriateeyeprotection.
Thelevelofthesolutioninthecontainershouldjustreachthetopofthecellsothatthewirehar-nesscompartmentisNOTsubmerged.Itmaybehelpfultocoilthewiringbeforeimmersingthecell.Thecellshouldsoakforafewminutesandthenrinsewithahighpressuregardenhose.Ifanydepositsarestillvisible,repeatsoakingandrinsing.Replacecellandinspectagainperiodically.
WinterizingTheAquaRiteProelectrolyticcellandflowdetectionswitchwillbedamagedbyfreezingwaterjustasyourpoolplumbingwould.Inareasofthecountrywhichexperiencesevereorextendedperiodsoffreezingtemperatures,besuretodrainallwaterfromthepump,filter,andsupplyandreturnlinesbeforeanyfreezingconditionsoccur.Theelectroniccontroliscapableofwithstandinganywinterweatherandshouldnotberemoved.
SpringStart-upDONOTturntheAquaRiteProon,untilthepoolwaterchemistryhasbeenbroughttotheproperlevels.Thisinformationcanbefoundonpage3.
13
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
InstallationInstallationmustbeperformedinaccordancewithLocalandNECcodes.
PreparingPool/SpaWaterRefertopage3forrecommendedchemicallevels.Thepool'schemistrymustbebalancedBE-FOREactivatingtheAquaRitePro.NOTE:Ifthepooldoesnothavenewwater,add1quart(1liter)ofmetalremoverand1quart(1liter)ofnon-copperbasedalgaecidetothepool,permanufac-turer'sinstructions.Thisensuresaquick,troublefreetransfertotheAquaRiteProsystem.
MountingtheAquaRiteProControlTheAquaRiteProiscontainedinaraintightenclosurethatissuitableforoutdoormounting.Thecontrolmustbemountedaminimumof5ft.(1.5meters)horizontaldistance(ormore,iflocalcodesrequire)fromthepool/spa.
Thecontrolisdesignedtomounthorizontallyonaflatsurfacewiththeknockoutsfacingdown-ward.Becausetheenclosurealsoactsasaheatsink(dispersesheatfrominsidethebox),itisimportantnottoblockthefoursidesofthecontrol.DonotmountAquaRiteProinsideapanelortightenclosedarea.
FROMPOOL
120/240 VACPOWER
TOPOOLFROM
SPA
TOSPA
Aqua Rite Pro
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
14
IfanAQL-CHEMkitwillbeused,takeintoconsiderationthespacenecessaryformountingtheunitaswellasrunningtheplumbinglinesfromtheAQL-CHEM'sprobecelltothepoolplumbing.RefertotheAQL-CHEMmanualforspecificmountinginstructions.
PlumbingEnsurethattheAquaRiteProinstallationdoesnotconstituteacrossconnectionwiththelocalpotablewatersupply.Consultlocalplumbingcodes.
TheAquaRiteProispackagedwithaTurboCell,flowswitchandcellunions.
Theflowswitchandcellshouldbeplumbedinthereturnlinetothepool/spa.Thepreferredinstallationisafter(downstream)allthepoolequipment(filter,heater,solar,etc.).Theelectrolyticcellandflowswitchteefittingaredesignedtobeplumbedinto2"(51mm)PVCpipe.Adapters(notincluded)canbeusedforsystemswith1½"(38mm)plumbing.
Forproperplumbing,refertotheoverviewdiagramonpage14.Alternateconfigurations#1showstheflowswitchcanalsobeinfrontofthecell.Configurations#2and#3allowforchlorina-tionofboththepoolandspaduringspaspilloveroperation,butpreventoverchlorinationofthespaduring"spaonly"operation.Neveruseconfiguration#4.
2
3 4
1
12”
12”min
min
Flow Switchbefore Cell
Flow Switchafter Cell
15
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Flow Switch: IMPORTANT:Theremustbeatleasta12"(25cm)straightpiperunbefore(upstream)theflowswitch.Iftheswitchisplumbedafterthecell,thecellcanbycountedasthe12"(25cm)ofstraightpipe.Toensureproperoperation,verifythatthearrowontheflowswitch(locatedontopofgrayhex)pointsinthedirectionofwaterflow.
Electrolytic Cell: Installusingtheunionsprovided.TightenunionsBYHANDforawatertightseal.Forpool/spacombinationsystemswithspillover,useconfigurations#2or#3abovetoallowchlorinationofboththepoolandspaduringspilloverbutpreventingoverchlorinationwhenoperatingthespaonly.
WiringPowermustbeshutoffatthecircuitbreakerbeforeperforminganywiring.BesuretofollowLocalandNECelectricalcodes.Toprovidesafeoperation,theAquaRitePromustbeproperlygroundedandbonded.
InputPower:WiretheAquaRitePrototheLOADSIDEofthefilterpumptimer.ItisveryimportantthattheAquaRiteProispoweredonlywhenthepumpisrunning.
RefertothewiringlabelontheAquaRiteProaswellasthediagrambelowtodeterminecorrectwiringconnections.TheAquaRiteProisshippedfromthefactorywiththeconfigurationjumpersin240VACposition.Ifusing120VAC,movethejumpersasshownbelow.IMPORTANT:Ifadispensingdevicewillbeused(page19),itmustbepoweredbythesameinputvoltageastheAquaRitePro.
Besuretoconnectthegroundwiretothegreengroundscrewterminallocatedonthebottomoftheenclosure.
SUBPANEL
TIMECLOCKAQUA
RITE ProAQUA
RITE Pro
PCB
GND
PCB
BONDINGLUG
BONDINGLOOP
PUMP
LINELOAD
GROUND
IMPORTANT:MOVE JUMPERS
TO POSITIONS SHOWN
TYPICAL 240 VAC WIRING120 VAC
Note: Wire the pump directly to the timeclock--do not use the Aqua Rite Pro as a junction box.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
16
BondingAlugusedforbondingisattachedtothebottomoftheAquaRiteProenclosure(twolugsarepro-videdforCanadianmodels).TheAquaRitePromustbebondedwithan8AWGcopperwire(6AWGCanada)tothepoolbondingsystem.Refertothediagrambelow.
ElectrolyticCellandFlowSwitchTheelectrolyticcellandflowswitchcablesareterminatedwithconnectorswhichplugintotheAquaRiteProforeasyattachmentandremoval.ThedooroftheAquaRitePromustbeopenandthefrontpanelremovedtoaccessthecellcableandflowswitchconnectors.Routetheflowswitchcablethroughoneoftheknockouts.Acutoutintheenclosureisprovidedforthecellcable.Thediagrambelowshowsthelocationoftheseconnections.
Bonding lug to poolbonding systemSecond bonding lug for
Canadian models only
Cutout forcell cable
Bottom of Aqua Rite Pro Enclosure
Cell Connector
Flow SwitchConnector
17
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Connector forAQL-CHEM
OptionalAQL-CHEMChemistryKit(includedwithAQR15-PRO-SD)PlugtheconnectorfromtheAQL-CHEMintothedesignatedconnectorontheAquaRiteProPCBasshownbelow.Fordetailedinstallationandoperationinformation,refertotheAQL-CHEMinstructions.
HaywardAquaRiteChlorinatorTheAquaRiteProcancontroloneormoreHaywardAquaRitechlorinatorswhenadditionalsanitizingcapacityisrequired.A4wireconnectionisusedtocommunicatetotheAquaRite(s)andcanbewiredupto500'apart.Anyoutdoorrated4conductorcablecanbeused.Re-fertothewiringdiagrambelowforproperwiringconnectiontotheAquaRite.NOTE:Theremustbeonly1"primary"unit.AllotherAquaRiteunitsmustbeconfiguredas"secondary".
TheAquaRite(s)powerinputmustbewiredtotheLOADSIDEofthefilterpumptimer(thesameastheAquaRitePro).
Aqua RitePro Aqua Rite
(Primary)Aqua Rite
(Secondary)
AdditionalAqua Rite(s)(if required)
Jumper RemovedFor Secondary(s)Jumper Installed
For Primary(Factory Default)
1234 GREEN
YELLOWBLACKRED
NOTE: Primary/Secondary jumper is located underneath small circuit board.
1 42 3
3 24 1GRN
GRNBLK
BLKYELYEL
RED
RED
Aqua RitePro Aqua Rite
green
yellow
black
red
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
18
OptionalpHDispenseWiringRequirestheuseofaHaywardAQL-CHEMsensingdeviceandanAQL-CHEM2,AQL-CHEM2-240orotherpHdispensingdevicerequiring120VACor240VACon/offcontrol.AscrewterminalblocklocatedontheenclosuresurfacebelowthetransformerisprovidedforconnectiontoanAQL-CHEM2,AQL-CHEM2-240orotherpHrelateddispensingdevice(peristalticpumps,solenoidvalves,etc.).AfterproperlyinstallingandconfiguringtheAQL-CHEMandthepHdispensingdevice,theAquaRiteProwillturnonthedispensingdevicewhenpHcorrectionisrequired.
IMPORTANT:ThedispensingdevicemustbepoweredbythesamevoltageusedtopowertheAquaRitePro.ConfiguretheoutputvoltagetothepHdevicebymovingthewiringconnectionsonthemainboardasshownbelow.
Example:IfanAQL-CHEM2-240(240VAC)willbeused,theAquaRitePromustbepoweredby240VAC.Connectthe240VACpigtailsuppliedwiththeAQL-CHEMtotheAquaRitePro’stermi-nalblockasshowninthediagram.TheAQL-CHEM2-240willthenplugintothepigtail’s240VACreceptacle.RefertotheAQL-CHEMmanualformoredetailedinformation.
240 VAC
120 VACN
L2
L1
L1
EP1
EP2
Ground
For 120VAC operationposition connectors as shown
Groundto AQL-CHEM2 Pigtail or
120VAC pH Dispensing Device
to AQL-CHEM2-240 Pigtail or240VAC pH Dispensing Device
WHITE
WHITE
BLACK
BLACK
EP1
EP3
240VAC pH Dispensing Device(Factory Default)
120VAC pH Dispensing Device
19
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
TroubleshootingThe“CHECKSYSTEM”LEDwillalertyouwhentheAquaRiteProdetectsanyofthefollowingcondi-tionsthatareabnormalandrequireattentionforoptimaloperationofyourpool.Press“<“or“>”toviewalloftheexisting“CheckSystem”conditions.
• Inspect Cell --Foroptimumoperation,youwillneedtoinspecttheAquaRiteProchlorinatorcellapproximatelyevery3monthsandcleanthecellifnecessary.TheAquaRiteProwillautomati-callyremindyouwhenitistimeanddisplay“InspectCell,+toreset”aspartoftherotatingDefaultMenu.Cleanthecell(page13)andthenpressthe“+”buttonduringthe“InspectCell”displaytoresetthetimer.
• Low Salt/Minerals or Very Low Salt/Minerals --WhenthesaltistoolowtheAquaRiteProwillgeneratelesschlorineandthelifeofthecellisdegraded.Checkthecellandcleanifneces-sarybeforeaddingsalt.
• High Salt/Amps/Minerals --TheAquaRiteProwillstopgeneratingchlorineunder certainhighsaltconditionsinordertoprotecttheinternalelectronicsfromdamage. Theonlywaytolowerthesaltlevelistopartiallydrainthepoolandaddfreshwater.
• Chlorinator Cell Sensor--Thecellsensoriseitheranopenorshortcircuit.
• Low Volts --Ifthechlorinatorcellvoltageistoolow.
• No Cell Power --Ifnochlorinatorcellpowerisdetectedontheprintedcircuitboard.
• Check Flow Switch --Iftheflowswitchinputisinvalid.
• Cell Power Error --Ifachlorinatorcellpowererrorisdetectedontheprintedcircuitboard.
• Cell Missing --Ifthechlorinatorisenabledbutnocellisdetected.
• CSM Comm Error: --IfChemistrySensingisenabledandtheChemistrySenseModule(CSM)isnotresponding.
• pH Probe Error --IftheCSMindicatesthatthereisaproblemwiththepHprobe.
• pH Low-CheckFeeder--IfapHlevelof6.9orlessisdetected,checkthefeederforproperoperation
• pH High-CheckFeeder--IfapHlevelof8.1orhigherisdetected,checkthechemicalsupplyandthefeederforproperoperation
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
20
• pH Timeout-CheckFeeder--Iftheunithasbeendispensingformorethantheselectedtimeoutwithoutreachingthedesiredlevel.Checkthechemicalsupplyandthefeeder.IfbothareOK,thetimeoutmayneedtobeincreased.Pressthe“+”buttontoresetthealarmandresumedispensing.
• pH Calibration Error --WhenusingthepHCalibrationWizardandtheenteredtestresultwasdifferentfromthemeasuredpHlevelby±1.0ormore.ThepHprobemayneedtobecleanedorreplaced.
• ORP Probe Error --IftheCSMindicatesthatthereisaproblemwiththeORPprobe.
• ORP Low -CheckChlor--IfanORPlevelof350mVorlessisdetected.Checkthechlorina-torforproperoperation.
• ORP High -CheckChlor--IfanORPlevelof950mVorhigherisdetected.Checkthechlorinatorforproperoperation.
• ORP High -ChlorOff--IfanORPlevelof950mVorhigherisdetectedandthechlorinefeedmodeisORPAutoSensing,thechlorinatorhasbeenturnedoff.Checkthechlorinatorforproperoperation.
• ORP Timeout -ChlorOff--Iftheunithasbeenchlorinatingformorethantheselectedsani-tizertimeoutwithoutreachingthedesiredlevel,thechlorinatorhasbeenturnedoff.Pressthe“+”buttontoresetthealarmandresumechlorination.
• Ambient Sensor--Iftheinternal(ambient)sensoriseitheropenorshortcircuit.
21
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
LIMITEDWARRANTY(effective03/01/12)HaywardwarrantsitsProLogic,OnCommandandE-CommandpoolautomationproductsaswellasitsAquaRite,AquaRitePro,AquaPlusandSwimPurechlorinationproductstobefreeofdefectsinmaterialsandworkmanship,undernormaluseandservice,foraperiodofthree(3)years.Haywardalsowarrants itsAquaTrolchlorinationproductstobefreeofdefects inmaterialsandworkmanship,undernormaluseandserviceforaperiodofone(1)year.Thesewarran-tiesareapplicablefromtheinitialdateofpurchaseonprivateresidentialswimmingpoolsintheUSandCanada. InstallationsofproductforuseoncommercialpoolsintheUSandCanadaiscoveredforaperiodofone(1)yearfordefectsinmaterialsandworkmanship.Haywardwarrantsallaccessoriesandreplacementpartsfortheabove-identifiedpoolautomationandchlorinationproductsforaperiodofone(1)year.Accessoriesalsoincluderemotes,actuators,basestations,temperaturesensors,flowswitchesandchemistryprobes.Eachofthesewarrantiesisnottransferableandappliesonlytotheoriginalowner.
Haywardshallnotberesponsibleforcartage,removal,repairorinstallationlabororanyothersuchcostsincurredinobtainingwarrantyreplacementsorrepair.
Proof of purchase is required forwarranty service. Ifwrittenproof of purchase is not provided, themanufacturingdatecodewillbethesoledeterminantofthedateofinstallationoftheproduct.Toobtainwarrantyserviceorrepair,pleasecontacttheplaceofpurchaseorthenearestHaywardauthorizedwar-rantyservicecenter.FormoreinformationonauthorizedservicecenterspleasecontacttheHaywardTechnicalServiceSupportCenter(61WhitecapRoad,NorthKingstownRI,02852)orvisittheHaywardwebsiteatwww.hayward.com.
WARRANTYEXCLUSIONS:
1.Materialsuppliedorworkmanshipperformedbyothersinprocessofinstallation.
2.Damageresultingfromimproperinstallationincludinginstallationonpoolslargerthantheproductrating.
3.Problemsresultingfromfailuretoinstall,operateormaintaintheproduct(s)inaccordancewiththerecommendationscontainedintheownersmanual(s).
4.Problemsresultingfromfailuretomaintainpoolwaterchemistryinaccordancewiththerecommenda-tionsintheownersmanual(s).
5.Problemsresultingfromtampering,accident,abuse,negligence,unauthorizedrepairsoralternations,fire,flood,lightning,freezing,externalwater,degradationofnaturalstoneusedinorimmediatelyadjacenttoapoolorspa,waroractsofGod.
6. Use of a non-genuineHayward replacement salt chlorination cell on anyHayward automation orchlorinationproductwillvoidthewarrantyforthatproduct.
TheexpresslimitedwarrantyaboveconstitutestheentirewarrantyofHaywardPoolProductswithrespecttoitsproductsandisinlieuofallotherwarrantiesexpressedorimplied,includingwarrantiesofmerchant-abilityorfitnessforaparticularpurpose.InnoeventshallHaywardPoolproductsberesponsibleforanyconsequential,specialorincidentaldamagesofanynature.Somestatesdonotallowalimitationonhowlonganimpliedwarrantylasts,ortheexclusionofincidentalorconsequentialdamages,sotheabovelimitationmaynotapplytoyou.Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrights,whichvaryfromstatetostate.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
22
Free Chlorine 1.0 - 3.0 ppm pH 7.2 - 7.8
Raise desired output % toincrease, lower desired output %to decrease -OR- increase ordecrease pump filtration time.
Too low - add soda ash.Too high - add muriatic acid
Alkalinity 80 - 120 ppm
Salt 2700 - 3400 ppm Add salt as required to increase.
Add baking soda to increase.
Stabilizer 30 - 50 ppm Add cyanuric acid to increase.
Calcium 200 - 400 ppm Add calcium to increase. Electrolytic Cell inspect & clean Refer to section in manual.
TEST IDEAL RANGE ADJUSTMENT REQUIRED
Drain and add water to decrease.
Add acid as required to decrease.
WE
EK
LYM
ON
THLY
QU
AR
TTE
RLY
ELECTROLYTIC CHLORINE GENERATORBASIC POOL MAINTENANCE REQUIREMENTS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Forfurtherinformationorconsumertechnicalsupport,visitourwebsiteat
www.hayward.com
HaywardisaregisteredtrademarkandAquaRite,ProLogicandAquaLogicaretrademarksofHaywardIndustries,Inc.©2013HaywardIndustries,Inc.
AllothertrademarksnotownedbyHaywardarethepropertyoftheirrespectiveowners.Haywardisnotinanywayaffiliatedwithorendorsedbythosethirdparties.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS