Download - A320 Chapter 24 Electrical Power
A319/A320/A321TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE
24 ELECTRICAL POWER
This document must be used for training purpose only
Under no circumstances should this document be used as a reference.
It will not be updated.
All rights reserved.No part of this manual may be reproduced in any form,
by photostat, microfilm, retrieval system, or any other means,without the prior written permission of Airbus Industrie.
GENERAL** System General Introduction (1) 1...............** Electrical System Location (1) 5................** System Diagram Description (1) 9................** System Main Control Panel Presentation (1) 23..** Circuit Breaker Panels Location (2) 27.........** ECAM Page Presentation (1) 39...................** System Warnings (3) 67..........................** ELEC SYS & Circuit Identification (2) 71.......
AC GENERATION** General Description (3) 89......................** IDG Description (3) 95..........................** IDG Cooling System (3) 99.......................** IDG Monitoring (2) 109..........................** IDG Disconnection / Reconnection (2) 113.......** IDG Components (2) 119..........................** IDG Oil Servicing (2) 129.......................** IDG Removal / Installation (3) 133.............** AC Main Generation D/O (3) 137..................** Generator Control Unit (GCU 1/2) D/O (3) 141...** Bus Tie Logic (3) 157............................** Main Generation Components (3) 161.............** AC Auxiliary Generation D/O (3) 173............** Auxiliary Generation Components (3) 177........** AC Emergency Generation D/O (3) 187............** EMER ELEC Power Logic Description (3) 195......** RAT Activation (3) 205..........................** CSM/G GCU D/O (3) 213............................** CSM/G Op. Test Electrical Circuit (3) 225......** Emergency Generation Components (3) 231........** Static Inverter Description/Operation (3) 245..** Static Inverter Components (3) 259.............** AC ESS BUS Switching (3) 269....................** Fuel Pumps ELEC PWR Supply (SMK CONFIG)(3) 277.
** AC/DC Sheddable Bus Supply (3) 289.............
EXTERNAL POWER** General Description (2) 297.....................** System Description/Operation (3) 301...........** Ground Power Control Unit D/O (3) 311..........** External Power Components (3) 315...............** Electrical Circuit (3) 323......................** AC/DC GND Service Distribution CMPNTS (3) 331..
DC GENERATION** DC Main Generation D/O (3) 343..................** DC Normal/ESS Generation SWTG D/O (3) 347......** DC Normal/ESS Generation SWTG ELEC CKT(3) 355..** Transformer Rectifier (TR) D/O 363.............** DC Main Generation Components (3) 375..........** Battery System Description/Operation (3) 389...** Battery Charge Limiter D/O 393..................** Battery Components (3) 399......................
AC AND DC LOAD DISTRIBUTION** Galley Supply Description/Operation (3) 409....** Galley Supply Components (3) 423................** Refuelling on Battery (2) 427...................
ECAM ELECTRICAL POWER INTERFACES** EGIU (3) 435.....................................** EGIU Components (3) 445.........................** AC/DC Bus OFF Warnings Logics (3) 449..........
CFDS/ELEC POWER INTERFACES** AC Generation Interfaces (3) 459................
MAINTENANCE PRACTICESSPECIFIC PAGES** CFDS Specific Page Presentation (3) 465......
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
EFFECTIVITYALL
24 ELECTRICAL POWER
UFD4200 TABLE OF CONTENTS Page
24 CONTENTSPage i
Dec 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
EFFECTIVITYALL
24 ELECTRICAL POWER
UFD4200 TABLE OF CONTENTS Page
24 CONTENTSPage ii
Dec 31/00
THIS PAGE INTENTIONALLY LEFT BLANK
24 - ELECTRICAL POWER
24-00-00 ELECTRICAL SYSTEM GENERALINTRODUCTION
CONTENTS:AC Electrical GenerationDC Electrical GenerationEmergency Generator
TMUELE001 LEVEL 1
EFFECTIVITY 24-00-00 Page 1Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 1EFFECTIVITYALL
ELECTRICAL SYSTEM GENERAL INTRODUCTION
The AC electrical system can be supplied by the twoengine generators, the APU generator or an externalpower source.The DC electrical system is supplied from the ACelectrical system or from the batteries as a back upsource.An Emergency Generator, driven by the Blue HydraulicSystem pressurized by the Ram Air Turbine in emergencyconfiguration, can supply part of the AC and DCelectrical systems in case of loss of normal supply.
TMUELE001-T01 LEVEL 1
EFFECTIVITY 24-00-00 Page 2Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 2EFFECTIVITYALL
ELECTRICAL SYSTEM GENERAL INTRODUCTIONTMUELE001-P01 LEVEL 1
EFFECTIVITY 24-00-00 Page 3Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 3EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELE001 LEVEL 1
EFFECTIVITY 24-00-00 Page 4Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 4EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 ELECTRICAL SYSTEM LOCATION
CONTENTS:AC Normal GenerationAC Emergency GenerationStatic InverterDC Normal GenerationDC Emergency Generation
TMUELE904 LEVEL 1
EFFECTIVITY 24-00-00 Page 1Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 5EFFECTIVITYALL
ELECTRICAL SYSTEM LOCATION
AC NORMAL GENERATION
There are 2 engine driven Integrated Drive Generator(IDGs).The IDG comprises two parts:
- the drive : Constant Speed Drive (CSD)- the generator.
Each IDG is installed on the associated engineaccessory gearbox.The AC Auxiliary Power Unit (APU) generator is locatedin the APU compartment.The external power receptacle is fitted forward of thenose landing gear bay.
AC EMERGENCY GENERATION
The AC Emergency Generation consists of a ConstantSpeed Motor (CSM) and an AC generator which form anassembly called Constant Speed Motor/Generator(CSM/G).The CSM/G is located in the main landing gear bay.
STATIC INVERTER
The Static Inverter is located in the right lateralavionics compartment.
DC NORMAL GENERATION
The two batteries (BAT 1 and BAT 2) and the two mainTransformer Rectifiers (TR1 and TR2) are located inthe right lateral avionics compartment.
DC EMERGENCY GENERATION
The Essential Transformer Rectifier (ESS TR) is locatedin the left lateral avionics compartment.
TMUELE904-T01 LEVEL 1
EFFECTIVITY 24-00-00 Page 2Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 6EFFECTIVITYALL
ELECTRICAL SYSTEM LOCATIONTMUELE904-P01 LEVEL 1
EFFECTIVITY 24-00-00 Page 3Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 7EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELE904 LEVEL 1
EFFECTIVITY 24-00-00 Page 4Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 8EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 ELECTRICAL SYSTEM DIAGRAMDESCRIPTION
CONTENTS:MAIN AC GenerationEmergency GeneratorAC TransferAC DistributionDC GenerationDC DistributionBatteriesStatic InverterGround/Flight BusesGalleysMain Electrical ConfigurationsSelf Examination
TMUELE105 LEVEL 1
EFFECTIVITY 24-00-00 Page 1Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 9EFFECTIVITYALL
ELECTRICAL SYSTEM DIAGRAM DESCRIPTION
MAIN AC GENERATION
ENGINE GENERATORSThe aircraft electrical system is supplied by twoengine driven generators regulated in speed byintegrated drives.Generator 1 is driven by engine 1.Generator 2 is driven by engine 2.Engine generator characteristics are: 115 Volts, 400Hertz, 90 KVA.
APU GENERATORA third AC generator driven by the APU can replaceone or both main engine generators throughout theflight envelope.APU generator characteristics are: 115 Volts, 400Hertz, 90 KVA.
EXTERNAL POWERA ground external power connector enables all busbars to be supplied.External power characteristics are : 115 Volts, 400Hertz 90 KVA (minimum).
EMERGENCY GENERATOR
An AC emergency generator is driven by the Ram AirTurbine hydraulic circuit. It automatically provides emergency power in case offailure of all main aircraft generators.Emergency generator characteristics are: 115 Volts,400 Hertz, 5 KVA.
AC TRANSFER
The AC transfer circuit enables AC buses to be suppliedby any generator or external power, via the BusTransfer Contactors ( BTCs ).Generators are never connected in parallel on the samebus.The priorities are:1 - GEN 1 (2) on AC BUS 1 (2)2 - EXT PWR even with one engine generator still running.3 - APU generator4 - The remaining engine generator.
AC DISTRIBUTION
AC BUS 1/2Each engine generator supplies its related AC bus.
AC ESS BUSThe AC ESS BUS is normally supplied by AC BUS 1, orby AC BUS 2 if AC BUS 1 fails.
AC ESS SHED BUSThe AC ESS SHED BUS is supplied by the AC ESS BUS.
115/26 V AUTO TRANSFORMERA 115 Volts to 26 Volts single phase autotransformersupplying a normal 26 Volts 400 Hertz sub-busbar isconnected to each main busbar and to the essentialbusbar.
TMUELE105-T01 LEVEL 1
EFFECTIVITY 24-00-00 Page 2Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 10EFFECTIVITYALL
ELECTRICAL SYSTEM DIAGRAM DESCRIPTIONTMUELE105-P01 LEVEL 1
EFFECTIVITY 24-00-00 Page 3Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 11EFFECTIVITYALL
ELECTRICAL SYSTEM DIAGRAM DESCRIPTION
DC GENERATION
DC generation is accomplished by TransformerRectifiers 1 and 2 (TR1 and TR2).All Transformer Rectifier characteristics are :maximum output of 200 A, 28 VDC.The ESS Transformer Rectifier unit replaces a faultymain TR to power the DC ESS BUS.
DC DISTRIBUTION
DC BUS 1/2DC BUS 1 and DC BUS 2 are supplied by their relatedTransformer Rectifier.DC BAT BUSThe DC BAT BUS is supplied by DC BUS 1 or by DC BUS 2if DC BUS 1 fails. Batteries can also supply the DCBAT BUS.DC ESS BUSThe DC ESS BUS is supplied by the DC BAT BUS. In anemergency, it is supplied either by BAT 2 or by theESS Transformer Rectifier.DC ESS SHED BUSThe DC ESS SHED BUS is supplied by the DC ESS BUS.
BATTERIES
Two batteries can be connected to the DC BAT BUS. Eachbattery has its own bus, HOT BUS 1 and HOT BUS 2. Theyare permanently supplied. Battery capacity is 23 Ah, nominal voltage is 24 VDC.
STATIC INVERTER
On batteries only, the static inverter connected tobattery 1 supplies the AC STAT INV BUS. Static Invertercharacteristics are : 115 Volts, 400 Hertz.
GROUND / FLIGHT BUSES
AC and DC ground flight buses are normally suppliedby the aircraft network, or directly by the externalpower unit, upstream of the External Power Contactor,without energizing the whole aircraft network.
GALLEYS
The main and secondary electrical circuits of thegalleys are supplied by AC BUS 1 and 2. The mainelectrical circuits are shed in single generatoroperation.
TMUELE105-T02 LEVEL 1
EFFECTIVITY 24-00-00 Page 4Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 12EFFECTIVITYALL
ELECTRICAL SYSTEM DIAGRAM DESCRIPTIONTMUELE105-P02 LEVEL 1
EFFECTIVITY 24-00-00 Page 5Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 13EFFECTIVITYALL
MAIN ELEC CONFIGURATIONS
GROUND SUPPLYOn ground, the complete circuit may be supplied by theexternal power unit or by the APU generator.
TMUELE105-T03 LEVEL 1
EFFECTIVITY 24-00-00 Page 6Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 14EFFECTIVITYALL
ELECTRICAL SYSTEM DIAGRAM DESCRIPTION - MAIN ELEC CONFIGURATIONS (GROUND SUPPLY)TMUELE105-P03 LEVEL 1
EFFECTIVITY 24-00-00 Page 7Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 15EFFECTIVITYALL
MAIN ELEC CONFIGURATIONS (CONT’D)
NORMAL CONFIGURATIONNormal flight Configuration.
TMUELE105-T04 LEVEL 1
EFFECTIVITY 24-00-00 Page 8Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 16EFFECTIVITYALL
ELECTRICAL SYSTEM DIAGRAM DESCRIPTION - MAIN ELEC CONFIGURATIONS (NORMAL CONFIGURATION)TMUELE105-P04 LEVEL 1
EFFECTIVITY 24-00-00 Page 9Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 17EFFECTIVITYALL
MAIN ELEC CONFIGURATIONS (CONT’D)
GROUND SERVICESFor ground service only, the AC and the DC groundflight buses can be supplied independently from thenormal circuit.
TMUELE105-T05 LEVEL 1
EFFECTIVITY 24-00-00 Page 10Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 18EFFECTIVITYALL
ELECTRICAL SYSTEM DIAGRAM DESCRIPTION - MAIN ELEC CONFIGURATIONS (GROUND SERVICES)TMUELE105-P05 LEVEL 1
EFFECTIVITY 24-00-00 Page 11Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 19EFFECTIVITYALL
MAIN ELEC CONFIGURATIONS (CONT’D)
LOSS OF MAIN GENERATORSIn flight, in case of total loss of all the maingenerators, and before the emergency generatorconnection, batteries 1 and 2 supply the AC and DC ESSbuses. This is a transient configuration, during RamAir Turbine extension or no emergency generatoravailable.When its parameters are correct, the emergencygenerator comes on line and supplies the AC and DC ESSbuses.When the speed is lower than 100 knots, the emergencygenerator is deactivated. The batteries supply theA.C. and D.C. ESS buses. The D.C. battery bus isrecovered.When the speed drops below 50 knots, the A.C. essentialbus disconnects from the static inverter.
TMUELE105-T06 LEVEL 1
EFFECTIVITY 24-00-00 Page 12Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 20EFFECTIVITYALL
ELECTRICAL SYSTEM DIAGRAM DESCRIPTION - MAIN ELEC CONFIGURATIONS (LOSS OF MAIN GENERATORS)TMUELE105-P06 LEVEL 1
EFFECTIVITY 24-00-00 Page 13Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 21EFFECTIVITYALL
SELF EXAMINATION
The static inverter operates:A - permanentlyB - when on batteries onlyC - when one engine generator fails
AC ESS BUS is normally supplied by the:A - AC BUS 1B - AC BUS 2C - Emergency Generator
DC BAT BUS can be supplied by the:A - DC BUS 1 or batteriesB - DC BUS 1, DC BUS 2 or batteriesC - DC BUS 2 or batteries
AC transfers enable AC buses:A - to be connected in parallelB - to be supplied by any generator or
external powerC - to be supplied by APU GEN or EXT PWR only
TMUELE105 LEVEL 1
EFFECTIVITY 24-00-00 Page 14Oct 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 22EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 ELECTRICAL SYSTEM MAIN CONTROLPANEL PRESENTATION
CONTENTS:IDG 1/2 PushbuttonsGEN 1/2 PushbuttonsAPU GEN PushbuttonEXT PWR PushbuttonBUS TIE PushbuttonAC ESS FEED PushbuttonBAT 1/2 PushbuttonsGALY & CAB PushbuttonMAINT BUS Switch
TMUELE202 LEVEL 1
EFFECTIVITY 24-00-00 Page 1Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 23EFFECTIVITYALL
ELECTRICAL SYSTEM MAIN CONTROL PANEL PRESENTATION
IDG 1/2 PUSHBUTTONS
When the IDG pushbutton is momentarily pressed, theIntegrated Drive Generator is disconnected from itsdrive shaft.It can only be reconnected by maintenance.
GEN 1/2 PUSHBUTTONS
In normal operation:the generator is energized and the line contactorcloses, when electrical parameters are correct.
When OFF:the generator is de-energized and the line contactoropens.
APU GEN PUSHBUTTON
In normal operation:the APU generator is energized and the line contactorcloses, if electrical parameters are correct and ifthe APU generator has priority.
When OFF:the APU generator is de-energized and the linecontactor opens.
EXT PWR PUSHBUTTON
When ON:the external power connects to the electrical networkif electrical parameters are correct and if it haspriority.
BUS TIE PUSHBUTTON
When set to AUTO:the Bus Tie Contactors open or close automaticallyaccording to priority to maintain the power supply toAC BUS 1 and AC BUS 2.
When OFF:the Bus Tie Contactors open.
AC ESS FEED PUSHBUTTON
In normal operation:the AC ESS bus is supplied by AC BUS 1.
When set to ALTN:the AC ESS bus is supplied by AC BUS 2.
BAT 1/2 PUSHBUTTONS
In normal operation:the Battery Charge Limiter automatically controls theconnection and disconnection of the battery to the DCBAT Bus.
When OFF:the battery is disconnected.T
MUELE202-T01 LEVEL 1
EFFECTIVITY 24-00-00 Page 2Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 24EFFECTIVITYALL
ELECTRICAL SYSTEM MAIN CONTROL PANEL PRESENTATIONTMUELE202-P01 LEVEL 1
EFFECTIVITY 24-00-00 Page 3Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 25EFFECTIVITYALL
GALY & CAB PUSHBUTTON
When set to AUTO:the main and secondary electrical circuits of thegalleys are supplied.The main electrical circuits are automatically shedwhen only one generator is operating.On ground, all galleys are available on APU or externalpower.
When set to OFF:main and secondary electrical circuits of the galleysare shed.Note : Two AC and two DC sheddable buses for cabin
systems are also affected by the switchposition.
MAINT BUS SWITCH
When the MAINT BUS switch is ON, and with only the EXTPWR available (green AVAIL light on), the AC and DCGRND FLT buses are supplied.The MAINT BUS switch is located in the forward galleyarea (ceiling panel).
TMUELE202-T01 LEVEL 1
EFFECTIVITY 24-00-00 Page 4Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 26EFFECTIVITYALL
24 - ELECTRICAL POWER
24-50-00 CIRCUIT BREAKER PANEL LOCATION
CONTENTS:GeneralCockpitPassenger CompartmentAvionics Compartment
TMUELBZ01 LEVEL 2
EFFECTIVITY 24-50-00 Page 1Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 27EFFECTIVITYALL
CIRCUIT BREAKER PANEL LOCATION
GENERAL
The green C/Bs are monitored by the SDAC (System DataAcquisition Concentrator - ATA 31).When a green C/B is tripped, after a time delay amessage "C/B TRIPPED", with the C/B location, appearson the ECAM E/WD.The number on the top of the C/B indicatesthe nominal current in AMP, i.e.: 3 AMP.
Specific C/Bs :- The WTB C/Bs (Wing Tip Brakes - ATA 27) cannot bemanually tripped.- The C/Bs with a yellow cap must be tripped whenflying on batteries only.
TMUELBZ01-T01 LEVEL 2
EFFECTIVITY 24-50-00 Page 2Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 28EFFECTIVITYALL
TMUELBZ01-P01 LEVEL 2
CIRCUIT BREAKER PANEL LOCATION - GENERAL
EFFECTIVITY 24-50-00 Page 3Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 29EFFECTIVITYALL
TMUELBZ01-P02 LEVEL 2
CIRCUIT BREAKER PANEL LOCATION - COCKPIT
EFFECTIVITY 24-50-00 Page 4Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 30EFFECTIVITYALL
TMUELBZ01-P03 LEVEL 2
CIRCUIT BREAKER PANEL LOCATION - COCKPIT
EFFECTIVITY 24-50-00 Page 5Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 31EFFECTIVITYALL
TMUELBZ01-P04 LEVEL 2
CIRCUIT BREAKER PANEL LOCATION - COCKPIT
EFFECTIVITY 24-50-00 Page 6Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 32EFFECTIVITYALL
TMUELBZ01-P05 LEVEL 2
CIRCUIT BREAKER PANEL LOCATION - COCKPIT
EFFECTIVITY 24-50-00 Page 7Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 33EFFECTIVITYALL
CIRCUIT BREAKER PANEL LOCATION - COCKPITTMUELBZ01-P06 LEVEL 2
EFFECTIVITY 24-50-00 Page 8Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 34EFFECTIVITYALL
CIRCUIT BREAKER PANEL LOCATION - PASSENGER COMPARTMENTTMUELBZ01-P07 LEVEL 2
EFFECTIVITY 24-50-00 Page 9Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 35EFFECTIVITYALL
CIRCUIT BREAKER PANEL LOCATION - AVIONICS COMPARTMENTTMUELBZ01-P08 LEVEL 2
EFFECTIVITY 24-50-00 Page 10Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 36EFFECTIVITYALL
CIRCUIT BREAKER PANEL LOCATION - AVIONICS COMPARTMENTTMUELBZ01-P09 LEVEL 2
EFFECTIVITY 24-50-00 Page 11Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 37EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBZ01 LEVEL 2
EFFECTIVITY 24-50-00 Page 12Sep 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 38EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 ECAM PAGE PRESENTATION
CONTENTS:GEN 1/2 IndicationsIDG IndicationsAPU GEN IndicationsEXT PWR IndicationsAC Bus Bars IndicationsAC Transfer IndicationsGalley Shed IndicationEMER GEN IndicationsTR 1/2/ESS IndicationsDC Bus Bars IndicationsDC Bat Bus IndicationsBat 1/2 IndicationsStatic Inverter Indications
TMUELE301 LEVEL 1
EFFECTIVITY 24-00-00 Page 1Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 39EFFECTIVITYALL
ECAM PAGE PRESENTATION
GEN 1/2 INDICATIONS
Engine generator parameters are green when normal.
TMUELE301-T01 LEVEL 1
EFFECTIVITY 24-00-00 Page 2Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 40EFFECTIVITYALL
GEN 1/2 INDICATIONSTMUELE301-P01 LEVEL 1
EFFECTIVITY 24-00-00 Page 3Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 41EFFECTIVITYALL
ECAM PAGE PRESENTATION
IDG INDICATIONS
The Integrated Drive Generator symbol and parametersare displayed here below.
TMUELE301-T02 LEVEL 1
EFFECTIVITY 24-00-00 Page 4Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 42EFFECTIVITYALL
IDG INDICATIONSTMUELE301-P02 LEVEL 1
EFFECTIVITY 24-00-00 Page 5Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 43EFFECTIVITYALL
ECAM PAGE PRESENTATION
APU GEN INDICATIONS
Only the white APU GEN message is displayed if the APUMASTER SW pushbutton is set to OFF.
TMUELE301-T03 LEVEL 1
EFFECTIVITY 24-00-00 Page 6Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 44EFFECTIVITYALL
APU GEN INDICATIONSTMUELE301-P03 LEVEL 1
EFFECTIVITY 24-00-00 Page 7Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 45EFFECTIVITYALL
ECAM PAGE PRESENTATION
EXT PWR INDICATIONS
External power parameters are displayed when theexternal power unit is plugged in and the deliveredparameters are correct.
TMUELE301-T04 LEVEL 1
EFFECTIVITY 24-00-00 Page 8Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 46EFFECTIVITYALL
EXT PWR INDICATIONSTMUELE301-P04 LEVEL 1
EFFECTIVITY 24-00-00 Page 9Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 47EFFECTIVITYALL
ECAM PAGE PRESENTATION
AC BUS BARS INDICATIONS
AC Bus bars are green when supplied, amber when notsupplied.
TMUELE301-T05 LEVEL 1
EFFECTIVITY 24-00-00 Page 10Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 48EFFECTIVITYALL
TMUELE301-P05 LEVEL 1
AC BUS BARS INDICATIONS
EFFECTIVITY 24-00-00 Page 11Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 49EFFECTIVITYALL
ECAM PAGE PRESENTATION
AC TRANSFER INDICATIONS
Transfer lines are green when the contactors areclosed.They are not displayed when the contactors are open.
TMUELE301-T06 LEVEL 1
EFFECTIVITY 24-00-00 Page 12Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 50EFFECTIVITYALL
AC TRANSFER INDICATIONSTMUELE301-P06 LEVEL 1
EFFECTIVITY 24-00-00 Page 13Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 51EFFECTIVITYALL
ECAM PAGE PRESENTATION
GALLEY SHED INDICATION
Galley shed is displayed when the galley electricalcircuits are not supplied or only partially suppliedby one generator.
TMUELE301-T07 LEVEL 1
EFFECTIVITY 24-00-00 Page 14Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 52EFFECTIVITYALL
GALLEY SHED INDICATIONTMUELE301-P07 LEVEL 1
EFFECTIVITY 24-00-00 Page 15Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 53EFFECTIVITYALL
ECAM PAGE PRESENTATION
EMER GEN INDICATIONS
Emergency generator parameters are displayed when theemergency Generator Line Contactor is closed.They are green when normal.
TMUELE301-T08 LEVEL 1
EFFECTIVITY 24-00-00 Page 16Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 54EFFECTIVITYALL
EMER GEN INDICATIONSTMUELE301-P08 LEVEL 1
EFFECTIVITY 24-00-00 Page 17Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 55EFFECTIVITYALL
ECAM PAGE PRESENTATION
TR 1/2/ESS INDICATIONS
Transformer Rectifier parameters are green whennormal.The parameters of the Essential Transformer Rectifierare only displayed when it is in use.
TMUELE301-T09 LEVEL 1
EFFECTIVITY 24-00-00 Page 18Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 56EFFECTIVITYALL
TR 1/2/ESS INDICATIONSTMUELE301-P09 LEVEL 1
EFFECTIVITY 24-00-00 Page 19Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 57EFFECTIVITYALL
ECAM PAGE PRESENTATION
DC BUS BARS INDICATIONS
DC Bus bars are green when supplied, amber when notsupplied.
TMUELE301-T10 LEVEL 1
EFFECTIVITY 24-00-00 Page 20Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 58EFFECTIVITYALL
DC BUS BARS INDICATIONSTMUELE301-P10 LEVEL 1
EFFECTIVITY 24-00-00 Page 21Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 59EFFECTIVITYALL
ECAM PAGE PRESENTATION
DC BAT BUS INDICATIONS
The DC Battery Bus is normally green.It becomes amber when the voltage is low.
TMUELE301-T11 LEVEL 1
EFFECTIVITY 24-00-00 Page 22Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 60EFFECTIVITYALL
DC BAT BUS INDICATIONSTMUELE301-P11 LEVEL 1
EFFECTIVITY 24-00-00 Page 23Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 61EFFECTIVITYALL
ECAM PAGE PRESENTATION
BAT 1/2 INDICATIONS
Battery parameters are green when normal.
TMUELE301-T12 LEVEL 1
EFFECTIVITY 24-00-00 Page 24Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 62EFFECTIVITYALL
BAT 1/2 INDICATIONSTMUELE301-P12 LEVEL 1
EFFECTIVITY 24-00-00 Page 25Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 63EFFECTIVITYALL
ECAM PAGE PRESENTATION
STATIC INVERTER INDICATIONS
Static Inverter parameters are only displayed duringStatic Inverter operation.
TMUELE301-T13 LEVEL 1
EFFECTIVITY 24-00-00 Page 26Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 64EFFECTIVITYALL
STATIC INVERTER INDICATIONSTMUELE301-P13 LEVEL 1
EFFECTIVITY 24-00-00 Page 27Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 65EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELE301 LEVEL 1
EFFECTIVITY 24-00-00 Page 28Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 66EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 ELECTRICAL SYSTEM WARNINGS
CONTENTS:IDG OIL LO PR/OVHTGEN FAULTBAT 2 FAULTGEN OVERLOADAC BUS 2 FAULTAC ESS BUS FAULTAC ESS BUS SHEDDC BUS 1 FAULTDC ESS BUS FAULTDC ESS BUS SHEDDC BAT BUS FAULTEMER CONFIG
TMUELE402 LEVEL 3
EFFECTIVITY 24-00-00 Page 1Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 67EFFECTIVITYALL
TMUELE402-P01 LEVEL 3
ELECTRICAL SYSTEM WARNINGS
EFFECTIVITY 24-00-00 Page 2Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 68EFFECTIVITYALL
TMUELE402 LEVEL 3
ELECTRICAL SYSTEM WARNINGS
EFFECTIVITY 24-00-00 Page 3Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 69EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELE402-P02 LEVEL 3
EFFECTIVITY 24-00-00 Page 4Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 70EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 ELECTRICAL SYSTEM AND CIRCUITIDENTIFICATION
CONTENTS:System IdentificationCircuit IdentificationComponent IdentificationMain Busbar IdentificationSub-Busbar IdentificationARINC Bus IdentificationVirtual Busbar IdentificationConnector IdentificationCoding System
TMUELAA01 LEVEL 2
EFFECTIVITY 24-00-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 71EFFECTIVITYALL
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION
An alpha numeric reference code is used to identifysystems, circuits and components.
SYSTEM IDENTIFICATION
The first letter of the reference code is used forsystem identification.A system is a set of circuits which fulfills a mainfunction.All components not specifically related to a circuitare identified by the letter V.The second letter defines the type of component.
CIRCUIT IDENTIFICATION
The second letter of the reference code is used forcircuit identification within the system.A circuit is a series of components with or withoutwiring, serving a specific function in a given system.All components not specifically related to a circuitare identified by the letter V.The second letter defines the type of component.Mechanical and electrical/electro-mechanicalcomponent have been differentiated by using the letterM in place of the second circuit letter for realmechanical equipment.
COMPONENT IDENTIFICATION
The four numeric characters, in front of the circuitidentification, identify the component within thecircuit.For electrical components, the reference numbers arefrom 1 to 999.Purely mechanical component are referenced from 5000to 7999.Four supplementary characters (left justified andwithout non significant zero) are used to identifysymetrical or multiple installations.Example: 1CC1 for FAC 1, 1CC2 for FAC 2.
MAIN BUSBAR IDENTIFICATION
The main busbars are identified using:- a sequence number,- letters XP for AC busbars and PP for DC busbars,- a phase letter (when applicable).
The first number (1 or 2 or 3...) indicates the busbarnumber. The letters (XP or PP) indicate thecorresponding power form (alternating current ordirect current).Example: 1 XP: main alternating current busbar 1.1 PP: main direct current busbar 1.1 XP-A: main alternating current busbar 1 phase A6 PP: direct current service busbar.
TMUELAA01-T01 LEVEL 2
EFFECTIVITY 24-00-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 72EFFECTIVITYALL
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATIONTMUELAA01-P01 LEVEL 2
EFFECTIVITY 24-00-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 73EFFECTIVITYALL
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION
SUB-BUSBAR IDENTIFICATION (CONT’D)
The sub-busbars are identified in the same way as themain busbar, but with three identification numbers:
- the first is identical to the number of thecorresponding main busbar,
- the two following numbers are the sub-busbarnumbers.
Example: 401 XP is the first sub-busbar of the AC ESSBUS.601 PP is the first sub-busbar of the SERVICE BUS.It should be noted that for the AC network, the thirtiesare used for the 26V-400Hz distribution.Example: 103 XP, 131 XP are sub-busbar of the mainbusbar 1XP, but 131 XP is the 26V-400Hz distributionsub-busbar.
TMUELAA01-T01 LEVEL 2
EFFECTIVITY 24-00-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 74EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELAA01 LEVEL 2
EFFECTIVITY 24-00-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 75EFFECTIVITYALL
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION
ARINC BUS IDENTIFICATION
ARINC 429 buses are numbered from 7000 to 7999 withthe ATA 100 prefix of the corresponding system.An ARINC 429 BUS shielded cable consists of two wires:one coloured in blue and one coloured in red.
TMUELAA01-T02 LEVEL 2
EFFECTIVITY 24-00-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 76EFFECTIVITYALL
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION - ARINC BUS IDENTIFICATIONTMUELAA01-P02 LEVEL 2
EFFECTIVITY 24-00-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 77EFFECTIVITYALL
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION
VIRTUAL BUSBAR IDENTIFICATION
Some circuit breakers do not have their supply on thebusbars of the aircraft distribution network. They aredirectly connected to the power source.In schematic representations, this supply appears asa virtual busbar.A virtual busbar is identified as follows:
- 1. a channel number,- 2. letters IW for virtual busbars followed byXP for AC busbars or PP for DC busbars.
Example: 1IWXP channel 1 of AC virtual busbar.1IWPP channel 1 of DC virtual busbar.Channel 1: consists of 1XP-101XP-103XP-110XP-131XP
1PP-101PP-103PP3PP-301PP701PP-703PP702PP-704PP901XP
Channel 2: consists of 2XP-202XP-204XP-210XP-212XP214XP-216XP-231XP2PP-202PP-204PP-206PP-208PP501PP-502PP601PP-602PP
Channel 4: for essential channel,it consists of: 401XP-431XP
801XP401PP801PP
TMUELAA01-T03 LEVEL 2
EFFECTIVITY 24-00-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 78EFFECTIVITYALL
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION - VIRTUAL BUSBAR IDENTIFICATIONTMUELAA01-P03 LEVEL 2
EFFECTIVITY 24-00-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 79EFFECTIVITYALL
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION
CONNECTOR IDENTIFICATION
Connections to components are identified by a suffixletter (or two for multiple connection parts) followingthe circuit identification
TMUELAA01-T04 LEVEL 2
EFFECTIVITY 24-00-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 80EFFECTIVITYALL
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION - CONNECTOR IDENTIFICATIONTMUELAA01-P04 LEVEL 2
EFFECTIVITY 24-00-00 Page 11May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 81EFFECTIVITYALL
TMUELAA01-P05 LEVEL 2
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION - CODING SYSTEM
EFFECTIVITY 24-00-00 Page 12May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 82EFFECTIVITYALL
TMUELAA01-P06 LEVEL 2
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION - CODING SYSTEM
EFFECTIVITY 24-00-00 Page 13May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 83EFFECTIVITYALL
TMUELAA01-P07 LEVEL 2
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION - CODING SYSTEM
EFFECTIVITY 24-00-00 Page 14May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 84EFFECTIVITYALL
TMUELAA01-P08 LEVEL 2
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION - CODING SYSTEM
EFFECTIVITY 24-00-00 Page 15May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 85EFFECTIVITYALL
TMUELAA01-P09 LEVEL 2
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION - CODING SYSTEM
EFFECTIVITY 24-00-00 Page 16May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 86EFFECTIVITYALL
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION - CODING SYSTEMTMUELAA01-P10 LEVEL 2
EFFECTIVITY 24-00-00 Page 17May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 87EFFECTIVITYALL
ELECTRICAL SYSTEM AND CIRCUIT IDENTIFICATION - CODING SYSTEMTMUELAA01-P11 LEVEL 2
EFFECTIVITY 24-00-00 Page 18May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 88EFFECTIVITYALL
24 - ELECTRICAL POWER
24-20-00 AC GENERATION - GENERALDESCRIPTION
CONTENTS:Normal OperationAbnormal Operation
TMUELAB01 LEVEL 3
EFFECTIVITY 24-20-00 Page 1Nov 30/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 89EFFECTIVITYALL
AC GENERATION - GENERAL DESCRIPTION
NORMAL OPERATION
GEN 1 and GEN 2 and APU GEN are monitored by a GeneratorControl Unit (GCU).This computer receives various parameters from thecorresponding generator, processes them and if theyare correct, provides a control signal to the GeneratorLine Contactor (GLC).For the External Power generation, the Ground PowerControl Unit (GPCU) has the same function as the GCUbut monitors the Ground Power Unit parameters.
TMUELAB01-T01 LEVEL 3
EFFECTIVITY 24-20-00 Page 2Nov 30/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 90EFFECTIVITYALL
AC GENERATION - GENERAL DESCRIPTION - NORMAL OPERATIONTMUELAB01-P01 LEVEL 3
EFFECTIVITY 24-20-00 Page 3Nov 30/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 91EFFECTIVITYALL
AC GENERATION - GENERAL DESCRIPTION
ABNORMAL OPERATION
If one generator parameter is not correct, theassociated GCU sends a signal to trip the GLC andtrigger warnings.
TMUELAB01-T02 LEVEL 3
EFFECTIVITY 24-20-00 Page 4Nov 30/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 92EFFECTIVITYALL
AC GENERATION - GENERAL DESCRIPTION - ABNORMAL OPERATIONTMUELAB01-P02 LEVEL 3
EFFECTIVITY 24-20-00 Page 5Nov 30/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 93EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELAB01 LEVEL 3
EFFECTIVITY 24-20-00 Page 6Nov 30/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 94EFFECTIVITYALL
24 - ELECTRICAL POWER
24-21-00 AC GENERATION - IDG DESCRIPTION
CONTENTS:GeneralGenerator DriveSpeed ControlControl and MonitoringSelf Examination
TMUELAC06 LEVEL 3
EFFECTIVITY 24-21-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 95EFFECTIVITYALL
AC GENERATION - IDG DESCRIPTION
GENERAL
Each engine drives its associated Integrated DriveGenerator (IDG) through the accessory gearbox. Thedrive speed varies according to the engine rating.The IDG is split in two parts: the drive and thegenerator.The IDG is cooled and lubricated by the IDG oil system.
GENERATOR DRIVE
Using the variable input speed, the generator driveproduces a constant speed on the output shaft via avariable ratio differential.The output constant speed is regulated at 12000 RPM.
SPEED CONTROL
A mechanical governor, acting on a hydraulic trim unit,controls the differential gear in order to maintainthe constant output speed.The differential gear also controls the oil systempumps in order to lubricate and cool the IDGcomponents.
CONTROL AND MONITORING
AC generation is monitored by the Generator ControlUnit (GCU). GEN 1 OR 2 pushbutton controls generatorexcitation via its Generator Control Unit.For safety reasons and IDG protection, an IDG1 (orIDG2) guarded pushbutton allows manual disconnectionof the IDG.
NOTE: Reset of the system can only be performed onground, with engines stopped, by pulling thereset handle mounted on IDG casing.
TMUELAC06-T01 LEVEL 3
EFFECTIVITY 24-21-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 96EFFECTIVITYALL
AC GENERATION - IDG DESCRIPTIONTMUELAC06-P01 LEVEL 3
EFFECTIVITY 24-21-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 97EFFECTIVITYALL
SELF EXAMINATION
How is IDG1 disconnected?A - Automatically, when an overspeed is
detected.B - Automatically, when a faulty parameter
is detected by the GCU.C - By pressing the IDG1 guarded pushbutton.
TMUELAC06 LEVEL 3
EFFECTIVITY 24-21-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 98EFFECTIVITYALL
24 - ELECTRICAL POWER
24-21-00 AC GENERATION - IDG COOLINGSYSTEM
CONTENTS:GeneralOperation PrincipleCold ConditionsFilter cloggedTemperature and Pressure MonitoringSelf Examination
TMUELAD05 LEVEL 3
EFFECTIVITY 24-21-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 99EFFECTIVITYALL
AC GENERATION - IDG COOLING SYSTEM
GENERAL
The IDG oil cooling system consists of a self-containedoil circuit and a fuel/oil heat exchanger.
OPERATION PRINCIPLE
A scavenge pump pumps the oil through the oil filterand the fuel/oil heat exchanger. A charge pump providesregulated oil supply pressure to the users.The engine fuel flow regulates the IDG oil temperaturethrough the fuel/oil heat exchanger.
TMUELAD05-T01 LEVEL 3
EFFECTIVITY 24-21-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 100EFFECTIVITYALL
AC GENERATION - IDG COOLING SYSTEM - OPERATION PRINCIPLETMUELAD05-P01 LEVEL 3
EFFECTIVITY 24-21-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 101EFFECTIVITYALL
AC GENERATION - IDG COOLING SYSTEM
COLD CONDITIONS
In cold conditions, due to the high oil viscosity, theoil pressure increases, the cooler bypass valve opens;oil runs in the IDG internal circuit.As the oil warms up, the cooler bypass valve closesand the oil flows through the fuel/oil heat exhanger.
TMUELAD05-T02 LEVEL 3
EFFECTIVITY 24-21-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 102EFFECTIVITYALL
AC GENERATION - IDG COOLING SYSTEM - COLD CONDITIONSTMUELAD05-P02 LEVEL 3
EFFECTIVITY 24-21-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 103EFFECTIVITYALL
AC GENERATION - IDG COOLING SYSTEM
FILTER CLOGGED
A clogged filter indication is provided by a localvisual Delta Pressure pop-out indicator (DPI).In case of clogging indication, a DPI reset can bedone in some conditions and associated with maintenanceprocedures.When the filter is clogged, the relief valve opens.
TMUELAD05-T03 LEVEL 3
EFFECTIVITY 24-21-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 104EFFECTIVITYALL
AC GENERATION - IDG COOLING SYSTEM - FILTER CLOGGEDTMUELAD05-P03 LEVEL 3
EFFECTIVITY 24-21-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 105EFFECTIVITYALL
AC GENERATION - IDG COOLING SYSTEM
TEMPERATURE AND PRESSURE MONITORING
For overheat detection, oil temperature sensorsmonitor the temperature of both input and output oil.A pressure switch operates in the event of a loss ofcharge oil pressure.
TMUELAD05-T04 LEVEL 3
EFFECTIVITY 24-21-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 106EFFECTIVITYALL
AC GENERATION - IDG COOLING SYSTEM - TEMPERATURE AND PRESSURE MONITORINGTMUELAD05-P04 LEVEL 3
EFFECTIVITY 24-21-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 107EFFECTIVITYALL
SELF EXAMINATION
When does the cooler bypass valve open?A - When an overtemperature is detected.B - During cold conditions operation.C - When the filter is clogged.
TMUELAD05 LEVEL 3
EFFECTIVITY 24-21-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 108EFFECTIVITYALL
24 - ELECTRICAL POWER
24-21-00 AC GENERATION - IDG MONITORING
CONTENTS:Temperature MonitoringTemperature Rise IndicationPressure MonitoringSelf Examination
TMUELAE04 LEVEL 2
EFFECTIVITY 24-21-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 109EFFECTIVITYALL
AC GENERATION - IDG MONITORING
TEMPERATURE MONITORING
If an overtemperature is detected at the IDG outlet,the associated alarms are triggered.If the temperature rises above 147°C, the ELEC ECAMpage is automatically displayed and the temperatureindication flashes. If the temperature exceeds 180°C,the indication turns from green to amber. Above 185°C, the MASTER CAUTION and IDG FAULT lightscome on, the single chime is triggered.
TEMPERATURE RISE INDICATION
If the temperature rise indication is over a givenlimit, a signal is sent to the CFDIU through the GroundPower Control Unit.GPCU: Ground Power Control Unit.CFDIU: Centralized Fault Display Interface Unit.Message on the MCDU: IDG 1 (or 2) HIGH DELTA TEMP(class 2 failure).
PRESSURE MONITORING
In case of loss of charge oil pressure thecorresponding indications and warnings are triggeredonly when the corresponding engine is running.The low pressure warning is inhibited, for IDGinput speed below 2000 RPM(Normal input speed range: between 4500 and 9120 RPM).
TMUELAE04-T01 LEVEL 2
EFFECTIVITY 24-21-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 110EFFECTIVITYALL
AC GENERATION - IDG MONITORINGTMUELAE04-P01 LEVEL 2
EFFECTIVITY 24-21-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 111EFFECTIVITYALL
SELF EXAMINATION
When does the IDG FAULT light come on?A - In case of overheat or low pressure
detectionB - In case of overheat and high pressure
detectionC - In case of overheat or high pressure
dectection
TMUELAE04 LEVEL 2
EFFECTIVITY 24-21-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 112EFFECTIVITYALL
24 - ELECTRICAL POWER
24-21-00 AC GENERATION - IDGDISCONNECTION AND RECONNECTION
CONTENTS:IDG DisconnectionIDG Reconnection
TMUELAF06 LEVEL 2
EFFECTIVITY 24-21-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 113EFFECTIVITYALL
AC GENERATION - IDG DISCONNECTION AND RECONNECTION
IDG DISCONNECTION
In case of oil overheat or drop of oil pressure, theamber IDG FAULT light comes on and the ECAM system istriggered.To disconnect the IDG from the accessory gearbox, theIDG pushbutton must be pressed.
NOTE: Do not maintain the IDG pushbutton pressed formore than 3 seconds to avoid damage of thesolenoid.
When the engine is not running, the IDG disconnectioncontrol signal is inhibited by the engine oil lowpressure switch.
NOTE: IDG FAULT light goes off when the failure signalis no longer present. The GEN FAULT amber lightcomes on.
TMUELAF06-T01 LEVEL 2
EFFECTIVITY 24-21-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 114EFFECTIVITYALL
AC GENERATION - IDG DISCONNECTION AND RECONNECTION - IDG DISCONNECTIONTMUELAF06-P01 LEVEL 2
EFFECTIVITY 24-21-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 115EFFECTIVITYALL
AC GENERATION - IDG DISCONNECTION AND RECONNECTION
IDG RECONNECTION
In flight, IDG disconnection is irreversible. Thesystem can only be reconnected on the ground withengines shut down to avoid damage to the drive shaftclutch device.A mechanical reset handle (ring) fitted to the IDGenables the drive to be reconnected while the engineis stationary on the ground.
NOTE: Do not reconnect the IDG when the engine is inwindmilling as it will damage the IDGdisconnection mechanism.
TMUELAF06-T02 LEVEL 2
EFFECTIVITY 24-21-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 116EFFECTIVITYALL
AC GENERATION - IDG DISCONNECTION AND RECONNECTION - IDG RECONNECTIONTMUELAF06-P02 LEVEL 2
EFFECTIVITY 24-21-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 117EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELAF06 LEVEL 2
EFFECTIVITY 24-21-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 118EFFECTIVITYALL
24 - ELECTRICAL POWER
24-21-00 AC GENERATION - IDG COMPONENTS
CONTENTS:Integrated Drive GeneratorOil Cooler
TMUELAH05 LEVEL 2
EFFECTIVITY 24-21-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 119EFFECTIVITYALL
AC GENERATION - IDG COMPONENTS
INTEGRATED DRIVE GENERATOR
IDENTIFICATIONFIN: 4000XU
LOCATIONZONE: 400
COMPONENT DESCRIPTIONThe IDG Input shaft has a shear neck to protect theengine gearbox and to safeguard the IDG against furtherdamage.
FILTER CLOGGING INDICATORThe sensing device for the filter clogging indicatoris automatically suppressed during cold oil runningconditions (high oil viscosity).The Delta Pressure pop-out Indicator (DPI) can be resetup to 3 times prior to IDG removal if these conditionsare fulfilled:- No metal particles in the filter and no otherindications.- Oil and filter change is required.- Write on the IDG DPI label that DPI reset is done.
TMUELAH05-T01 LEVEL 2
EFFECTIVITY 24-21-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 120EFFECTIVITYALL
AC GENERATION - IDG COMPONENTS - INTEGRATED DRIVE GENERATOR / FILTER CLOGGING INDICATORTMUELAH05-P01 LEVEL 2
EFFECTIVITY 24-21-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 121EFFECTIVITYALL
AC GENERATION - IDG COMPONENTS
INTEGRATED DRIVE GENERATOR
QUICK ATTACH DETACHThe IDG is attached to the engine gearbox by a QuickAttach Detach device.
OIL LEVEL INDICATOR
1 - If the oil level is above the line between thegreen and the yellow band (IDG cold) or above theyellow band (IDG hot), oil servicing is required.2 - If the oil level is within the green band (IDGcold) or within green or yellow bands (IDG hot), oilservicing is not required.3 - If the oil level is below the green band, oilservicing is required.Note : The yellow band corresponds to the oil thermalexpansion margin.
TMUELAH05-T02 LEVEL 2
EFFECTIVITY 24-21-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 122EFFECTIVITYALL
TMUELAH05-P02 LEVEL 2
AC GENERATION - IDG COMPONENTS - INTEGRATED DRIVE GENERATOR - QUICK ATTACH DETACH / OILLEVEL INDICATOR
EFFECTIVITY 24-21-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 123EFFECTIVITYALL
AC GENERATION - IDG COMPONENTS
INTEGRATED DRIVE GENERATOR
OIL FILTER
DISCONNECT MECHANISMThe disconnect mechanism consists of a solenoid, aspring-loaded disconnect plunger with threaded pawl,a worm shaft, and a reset handle.The purpose of the disconnect mechanism is to uncouplethe power supply of the gearbox from the IDG in theevent of an IDG failure.Once uncoupled, the disconnect mechanism cannot bereset in flight.
TMUELAH05-T03 LEVEL 2
EFFECTIVITY 24-21-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 124EFFECTIVITYALL
AC GENERATION - IDG COMPONENTS - INTEGRATED DRIVE GENERATOR - OIL FILTER / DISCONNECTMECHANISM
TMUELAH05-P03 LEVEL 2
EFFECTIVITY 24-21-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 125EFFECTIVITYALL
AC GENERATION - IDG COMPONENTS
OIL COOLER
IDENTIFICATIONFIN: 4000XU
LOCATIONZONE: 400
TMUELAH05-T04 LEVEL 2
EFFECTIVITY 24-21-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 126EFFECTIVITYALL
TMUELAH05-P04 LEVEL 2
AC GENERATION - IDG COMPONENTS - OIL COOLER
EFFECTIVITY 24-21-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 127EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELAH05 LEVEL 2
EFFECTIVITY 24-21-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 128EFFECTIVITYALL
24 - ELECTRICAL POWER
24-21-00 AC GENERATION - IDG OIL SERVICING
CONTENTS:Oil Replenishing of the IDG after Replacement of theIDG or a Cooling Circuit Component
TMUELAI04 LEVEL 2
EFFECTIVITY 24-21-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 129EFFECTIVITYALL
AC GENERATION - IDG OIL SERVICING
OIL REPLENISHING OF THE IDG AFTER REPLACEMENT OF THEIDG OR A COOLING CIRCUIT COMPONENT
Refer to your Aircraft Maintenance Manual whenperforming this procedure by yourself.
VIDEO SEQUENCEDo not touch the IDG system components for a shorttime after the engine is shutdown. The enginecomponents stay hot for sometime and can cause injury.If the oil is below the minimum level (the green band),add oil to the IDG.Now prepare the IDG for servicing.Remove the caps from the overflow drain and pressurefill valves.First connect a drain hose to the overflow drain valve,then connect the pressure fill hose from a serviceunit to the pressure fill valve.Using the service unit, add oil until the level reachesthe FULL mark and the oil overflows through the drainhose.Drain oil until the oil level moves down to the greenband.Remove the drain and pressure fill hoses fromconnectors and reinstall the caps.Finally, perform a leak test. Do another check of theoil level 5 minutes later.
TMUELAI04-T01 LEVEL 2
EFFECTIVITY 24-21-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 130EFFECTIVITYALL
AC GENERATION - IDG OIL SERVICING - OIL REPLENISHING OF THE IDG AFTER REPLACEMENT OF THEIDG OR A COOLING CIRCUIT COMPONENT
TMUELAI04-P01 LEVEL 2
EFFECTIVITY 24-21-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 131EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELAI04-T01 LEVEL 2
EFFECTIVITY 24-21-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 132EFFECTIVITYALL
24 - ELECTRICAL POWER
24-21-00 AC GENERATION - IDGREMOVAL/INSTALLATION
CONTENTS:IDG RemovalIDG Installation
TMUELAJ04 LEVEL 3
EFFECTIVITY 24-21-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 133EFFECTIVITYALL
AC GENERATION - IDG REMOVAL/INSTALLATION
IDG REMOVAL
Refer to your Aircraft Maintenance Manual whenperforming this procedure by yourself.
VIDEO SEQUENCEBefore removing the IDG the engine must be shutdownfor at least 5 minutes to prevent burns because theoil stays hot for a few minutes.First of all, the IDG must be drained and the oil tubedisconnected and removed.Also remove the banjo couplings and note their initialposition, then disconnect the three electricalconnectors from the IDG.Remove the cover plate of the IDG terminal box anddisconnect the output cables.Next, place the special dolly in position and raiseit up to the IDG. When the IDG is on the dolly releasethe Quick Attach/Detach coupling, then pull the IDGforward to disengage it.
IDG INSTALLATION
Refer to your Aircraft Maintenance Manual whenperforming this procedure by yourself.
VIDEO SEQUENCEUsing the dolly, lift the IDG up to its position andalign the open marks on the Quick Attach/Detachcoupling.When the IDG is engaged tighten the couplingsufficiently to secure it, then remove the dolly,reconnect the electrical connectors and reinstall theoil tubes.T
MUELAJ04-T01 LEVEL 3
EFFECTIVITY 24-21-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 134EFFECTIVITYALL
AC GENERATION - IDG REMOVAL/INSTALLATIONTMUELAJ04-P01 LEVEL 3
EFFECTIVITY 24-21-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 135EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELAJ04 LEVEL 3
EFFECTIVITY 24-21-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 136EFFECTIVITYALL
24 - ELECTRICAL POWER
24-22-00 AC GENERATION - AC MAINGENERATION D/O
CONTENTS:GeneratorGenerator Control Unit SupplyGenerator Operation ControlGenerator MonitoringGenerator 1Generator ResetSelf Examination
TMUELAK06 LEVEL 3
EFFECTIVITY 24-22-00 Page 1Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 137EFFECTIVITYALL
AC GENERATION - AC MAIN GENERATION D/O
GENERATOR
The generator is a conventional 3 co-axial componentbrushless generator which consists of:
- a Permanent Magnet Generator (PMG),- a rotating diode pilot exciter,- the generator itself.
The generator is driven at a constant speed of 12000 RPMand cooled by oil spraying.
GENERATOR CONTROL UNIT SUPPLY
The Permanent Magnet Generator (PMG) supplies theexciter field through the Generator Control Relay (GCR)and the Generator Control Unit through a RectifierUnit.The Generator Control Unit (GCU) supply from theaircraft network is duplicated (Back up supply). Thesupply is taken from the DC essential system.The excitation control and regulation module keeps thevoltage at the nominal value at the Point Of Regulation(POR).
GENERATOR OPERATION CONTROL
The generator is controlled by the correspondinggenerator pushbutton. When pressed in, if the generatorspeed is high enough, the generator is energized.If the delivered parameters are correct (Power Readyrelay closed) the Generator Line Contactor (GLC) closesto supply its network.
GENERATOR MONITORING
The FAULT light comes on when any generator parameteris not correct or when the Generator Line Contactoris open.The generator failure signal is sent to SDAC 1 and 2through the Electrical Generation Interface Unit(EGIU). When the engine is shut down, the correspondingGEN FAULT light is on.
NOTE: During the AVIONICS SMOKE procedure, the FAULTlight does not come on when the GEN1 LINEpushbutton is set to off.
GENERATOR 1
To avoid complete loss of fuel pumps electrical supplyduring the smoke procedure, the GEN 1 LINE pushbuttonis released out to open the line contactor.Generator 1 is still excited and supplies fuel pumps1LH and 1RH.
GENERATOR RESET
When the GEN pushbutton is released out after a faultdetection, the Generator Control Unit is reset.The Generator Control Relay (GCR) and the Power Readyrelay (PR) are reset.
TMUELAK06-T01 LEVEL 3
EFFECTIVITY 24-22-00 Page 2Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 138EFFECTIVITYALL
AC GENERATION - AC MAIN GENERATION D/OTMUELAK06-P01 LEVEL 3
EFFECTIVITY 24-22-00 Page 3Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 139EFFECTIVITYALL
SELF EXAMINATION
With the GEN 1 and 2 on line, when does the GEN 1FAULT light come on?
A - As soon as the GEN 1 LINE pushbutton isreleased out.
B - When any GEN 1 parameter is not correct.C - When any GEN 1 parameter is not correct
and the GEN 1 pushbutton is released out.
When released out, what does the GEN 1 LINEpushbutton enable?
A - To close GLC 1 and supply the fuel pumpsfrom the AC NORMAL BUS.
B - To open GLC 1 and supply the fuel pumpsfrom GEN 1.
C - To close the BTC and supply the fuelpumps from the AC NORMAL BUS.
TMUELAK06 LEVEL 3
EFFECTIVITY 24-22-00 Page 4Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 140EFFECTIVITYALL
24 - ELECTRICAL POWER
24-22-00 AC GENERATION - GENERATORCONTROL UNIT (GCU 1/2) D/O
CONTENTS:GeneralVoltage RegulationControl and ProtectionIndications and WarningsBITESelf Examination
TMUELAL01 LEVEL 3
EFFECTIVITY 24-22-00Page 1
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 141EFFECTIVITYALL
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O
GENERAL
The Generator Control Unit has four differentfunctions:
- Voltage regulation.- Generator control and protection of the networkand generator.
- Control of the various indications andwarnings.
- System self monitoring and Test.The GCU is supplied by the Permanent Magnetic Generator(PMG).The GCU is also supplied by the aircraft network(Back-Up supply).
TMUELAL01-T01 LEVEL 3
EFFECTIVITY 24-22-00Page 2
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 142EFFECTIVITYALL
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O - GENERAL
TMUELAL01-P01 LEVEL 3
EFFECTIVITY 24-22-00Page 3
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 143EFFECTIVITYALL
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O
VOLTAGE REGULATION
The voltage regulation is achieved by regulating thegenerator excitation current.It also supplies the exciter field through theGenerator Control Relay, which is normally closed, andthrough a rectifier.When the generator starts running, the PermanentMagnetic Generator supplies the GCU.The exciter field current is reduced inside the GCUuntil 335 Hz is obtained.As the PMG frequency is below the threshold, thegenerator excitation is reduced through the excitationcontrol module.The voltage regulation shutdown signal, generated bythe protection module, triggers the voltage regulationshutdown control module which simulates a highgenerator load signal via the current limit module.As soon as the PMG frequency is over the threshold,the generator excitation is regulated normally.The excitation current depends on the comparisonbetween the voltage sensed at the Point Of Regulation(POR) and a reference voltage.As the parameters are correct, the Generator LineContactor closes.The generator excitation also depends on the load.If a fault is detected by the GCU protection module,the voltage regulation shutdown control modulesimulates a high generator load signal. The exciterfield coils are no longer supplied.
NOTE: the GCR and the GLC are tripped.
TMUELAL01-T02 LEVEL 3
EFFECTIVITY 24-22-00Page 4
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 144EFFECTIVITYALL
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O - VOLTAGE REGULATION
TMUELAL01-P02 LEVEL 3
EFFECTIVITY 24-22-00Page 5
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 145EFFECTIVITYALL
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O
CONTROL AND PROTECTION
The generator control and protection functions aremainly provided by means of the Generator Control Relayand the Power Ready relay.The GCR controls the generator excitation. The PRcontrols the Line Contactor and activates thecorresponding warning.
ENGINE FIRE AND OPEN FEEDER CABLE PROTECTIONThe feeder cable is duplicated from the engine pylonto the forward cargo compartment. Each cable ismonitored by a Current Transformer and a sensor.If an open parallel condition exits, or if the EngineFire pushbutton is released out, the GCU trips the GCRand the GLC and turns off the voltage regulator.The Ground Power Control Unit (GPCU) determines whethera fire trip or an open cable trip has occured.
TMUELAL01-T03 LEVEL 3
EFFECTIVITY 24-22-00Page 6
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 146EFFECTIVITYALL
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O - CONTROL AND PROTECTION - ENGINEFIRE AND OPEN FEEDER CABLE PROTECTION
TMUELAL01-P03 LEVEL 3
EFFECTIVITY 24-22-00Page 7
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 147EFFECTIVITYALL
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O
CONTROL AND PROTECTION - DIFFERENTIAL PROTECTION
The differential protection prevents the electricalwiring between the two detection Current Transformersfrom being damaged.The protected area is divided into two parts (ZONE 1& ZONE 2).
ZONE 1The zone 1 protected area comprises the generator coilsand feeders between the IDG Current Transformer (CT)and the GLC.The zone 2 protected area comprises the wiring betweenthe GLC and the Current Transformer (CT).In the event of a short circuit between phases or tothe ground, a noticeable difference betweentransformer currents activates the protection system.When activated the protection system opens GLC and BTC(GEN FAULT light comes on) and the generator is stillexcited.If the fault persits, the Generator Control Relay istripped thus the generator is de-excited. The Bus TieContactor closes automatically, therefore allowing thenetwork to be supplied by another generation source.In that configuration, the short circuit is locatedin zone 1.When the generator is cut off, the protection systemof zone 2 remains operational.The IDG senses a null current. If there is no shortcircuit in zone 2, the sum of currents sensed by theline CTs is null (opposite current direction).If a short circuit occurs in zone 2, an unbalancedcurrent is detected by the GCU which activates theprotection system.
ZONE 2If a short circuit occurs, the protection system opensthe GLC and confirms the BTC opening. The generatoris still excited. The GEN1 FAULT light comes on.If the fault does not persist, the short circuit hasbeen isolated and the GCR is tripped thus the generatoris de-excited.In this case, the BTC remains open and is locked out,and the AC BUS 1 supply cannot be recovered. The ACESSential Bus supply is recovered through the AC ESSFEED control.
The system is recovered by resetting the protectionsystem from the associated GEN pushbutton. Two resetactions maximun can be performed.The Generator Control Relay (GCR) closes enablinggenerator excitation. The Power Ready relay isre-energized to control the Generator Line Contactorclosing.The Bus Tie Contactor lock out function is removed.The DP Counter is reset either by pressing the DP Resetpushbutton on the front face of the GCU or at eachpower-up.
TMUELAL01-T04 LEVEL 3
EFFECTIVITY 24-22-00Page 8
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 148EFFECTIVITYALL
TMUELAL01-P04 LEVEL 3
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O - CONTROL AND PROTECTION -DIFFERENTIAL PROTECTION
EFFECTIVITY 24-22-00Page 9
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 149EFFECTIVITYALL
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O
CONTROL AND PROTECTION - OTHER PROTECTIONS
The GCR and PR relays are deenergized by the Protectionmodule which processes various electrical parametersnecessary for the protection functions.Note that the overload protection is only processedto give warning on the ECAM. In underspeed conditionsthe Under-Frequency and the Under-Voltage protectionsare inhibited.If the GLC remains closed (welded contact) aftertripping of the PR relay, the BTC lock-out functionis activated.
TMUELAL01-T05 LEVEL 3
EFFECTIVITY 24-22-00Page 10
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 150EFFECTIVITYALL
TMUELAL01-P05 LEVEL 3
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O - CONTROL AND PROTECTION - OTHERPROTECTIONS
EFFECTIVITY 24-22-00Page 11
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 151EFFECTIVITYALL
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O
INDICATIONS AND WARNINGS
IDG indications and warnings are computed by the GCU.The warnings and indications triggered are:
- generator “FAULT” amber warning light with ECAMactivation
- galley “FAULT” amber warning light with ECAMactivation
- IDG “FAULT” amber warning light with ECAMactivation.
The GCU also processes the following indications:- generator load, frequency, IDG oiltemperature and low pressure which are alsodisplayed on the ECAM system.
TMUELAL01-T06 LEVEL 3
EFFECTIVITY 24-22-00Page 12
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 152EFFECTIVITYALL
TMUELAL01-P06 LEVEL 3
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O - INDICATIONS AND WARNINGS
EFFECTIVITY 24-22-00Page 13
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 153EFFECTIVITYALL
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O
BITE
The GCU contains an integral BITE system to help insystem trouble shooting.The BITE system detects and isolates active and passivefailures.The BITE system consists of two sections:
- Operational BITE- Maintenance BITE
After generator tripping, the operational BITEidentifies the protection, analyses the conditions anddetermines the fault origin.The Maintenance BITE completes the operational BITEand performs a self-test of the GCU to provide anindication of system integrity. Only the 7 last legfaults are kept in the non volatile memory.
TMUELAL01-T07 LEVEL 3
EFFECTIVITY 24-22-00Page 14
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 154EFFECTIVITYALL
TMUELAL01-P07 LEVEL 3
AC GENERATION - GENERATOR CONTROL UNIT (GCU 1/2) D/O - BITE
EFFECTIVITY 24-22-00Page 15
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 155EFFECTIVITYALL
SELF EXAMINATION
What is the condition of the exciter field when thegenerator starts running?
A - Not electrically supplied.B - Reduced.C - Increased.
What happens when a generator fault is detected?A - The exciter field is no longer supplied
and the GCR trips.B - The exciter field is still supplied and
the GCR stays closed.C - The exciter field is increased and the
GCR trips.
What is the configuration of the electrical networkwhen a zone 1 differential protection has occuredon GEN 1?
A - The whole electrical network is stilloperational.
B - AC BUS 1 is lost.C - AC BUS 2 is lost.
What is the configuration of the electrical networkwhen a zone 2 differential protection has occuredon GEN 1?
A - The whole electrical network is stilloperational.
B - AC BUS 1 is lost.C - AC BUS 2 is lost.
How is a differential protection trip reset?A - At any time from the front face of the
GCU.B - At any time from the corresponding GEN
pushbutton.C - Two reset actions maximum from the
corresponding GEN pushbutton.
What happens if an overload warning occurs?A - The GCR and PR relays stay energized.B - The GCR and PR relays are de-energized.C - The GCR relay stays energized and PR
relay is de-energized.
What happens if a parallel feeder becomes open?A - The GCR relay and the GLC stay closed.B - The GCR relay stays closed and the GLC
opens.C - The GCR relay and the GLC are opened.
TMUELAL01 LEVEL 3
EFFECTIVITY 24-22-00Page 16
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 156EFFECTIVITYALL
24 - ELECTRICAL POWER
24-22-00 AC GENERATION - BUS TIE LOGIC
CONTENTS:External Power ONAPU Gen and IDG 2 ONIDG 1 Gen ONNormal ConfigurationSelf Examination
TMUELAM02 LEVEL 3
EFFECTIVITY 24-22-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 157EFFECTIVITYALL
AC GENERATION - BUS TIE LOGIC
The transfer circuit enables to supply both or eitherAC electrical network from one of the four powersources via Bus Tie Contactors.
EXTERNAL POWER ON
With the battery pushbuttons in the OFF position, assoon as the external power is available and selectedON, the Ground Power Control Unit supplies Bus TieContactor 1.BTC 1 being closed, the BAT BUS 3PP is supplied allowingBTC 2 to be energized. The whole aircraft electricalnetwork is supplied by the External Power.
APU GEN AND IDG 2 ON
With APU generator ON and IDG 2 generator ON, the BusTie Contactor 1 is energized and Bus Tie Contactor 2is de-energized.AC BUS 1 is supplied from APU GEN.AC BUS 2 is supplied from IDG 2.
IDG 1 GEN ON
With only the IDG 1 generator ON, both Bus TieContactors are energized.The whole aircraft electrical network is supplied fromthe IDG 1 generator. When the Bus Tie pushbutton isset to OFF ( release out ) , both BTCs are de-energizedand IDG 1 Generator supplies AC BUS 1. AC BUS 2 islost.
NORMAL CONFIGURATION
In normal configuration both Bus Tie Contactors aredeenergized.IDG 1 generator supplies AC BUS 1.IDG 2 generator supplies AC BUS 2.
TMUELAM02-T01 LEVEL 3
EFFECTIVITY 24-22-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 158EFFECTIVITYALL
AC GENERATION - BUS TIE LOGIC
TMUELAM02-P01 LEVEL 3
EFFECTIVITY 24-22-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 159EFFECTIVITYALL
SELF EXAMINATION
What is the configuration if both BTCs are open?A - APU GEN supplies AC BUS 1 and EXT PWR
supplies AC BUS 2.B - APU GEN supplies AC BUS 1 and GEN 2
supplies AC BUS 2.C - GEN 1 suppplies AC BUS 1 and GEN 2
supplies AC BUS 2.
What is the configuration if BTC 1 is open and BTC2 is closed?
A - GEN 1 supplies AC BUS 1 and EXT PWRsupplies AC BUS 2.
B - APU GEN supplies AC BUS 1 and EXT PWRsupplies AC BUS 2.
C - EXT PWR supplies AC BUS 1 and GEN 2supplies AC BUS 2.
What is the configuration if both BTCs are closed?A - GEN 1 supplies AC BUS 1 and GEN 2
supplies AC BUS 2.B - APU GEN or EXT PWR or one GEN supplies
AC BUS 1 and AC BUS 2.C - APU GEN supplies AC BUS 1 and EXT PWR
supplies AC BUS 2.
TMUELAM02 LEVEL 3
EFFECTIVITY 24-22-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 160EFFECTIVITYALL
24 - ELECTRICAL POWER
24-22-00 AC GENERATION - MAIN GENERATIONCOMPONENTS
CONTENTS:Generator Control UnitBus Tie Contactor - Generator Line ContactorAuto Transformer6 Hole Current Transformer3 Hole Current Transformer
TMUELAN01 LEVEL 3
EFFECTIVITY 24-22-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 161EFFECTIVITYALL
AC GENERATION - MAIN GENERATION COMPONENTS
GENERATOR CONTROL UNIT
IDENTIFICATIONFIN: 1XU1 (GCU1), 1XU2 (GCU2)
LOCATIONZONE: 121
COMPONENT DESCRIPTIONThe 3 GCUs are identical and interchangeable. The GCUfunctions (GCU 1,2 and APU) are selected by pinprogramming.
TMUELAN01-T01 LEVEL 3
EFFECTIVITY 24-22-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 162EFFECTIVITYALL
TMUELAN01-P01 LEVEL 3
AC GENERATION - MAIN GENERATION COMPONENTS - GENERATOR CONTROL UNIT
EFFECTIVITY 24-22-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 163EFFECTIVITYALL
AC GENERATION - MAIN GENERATION COMPONENTS
BUS TIE CONTACTOR / GENERATOR LINE CONTACTOR
IDENTIFICATIONFIN: 9XU1 (GLC1), 11XU1 (BTC1), 9XU2 (GLC2), 11XU2(BTC2)
LOCATIONZONE: 212
COMPONENT DESCRIPTIONThey are Plug Type Contactors.
TMUELAN01-T02 LEVEL 3
EFFECTIVITY 24-22-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 164EFFECTIVITYALL
AC GENERATION - MAIN GENERATION COMPONENTS - BUS TIE CONTACTOR / GENERATOR LINE CONTACTOR
TMUELAN01-P02 LEVEL 3
EFFECTIVITY 24-22-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 165EFFECTIVITYALL
AC GENERATION - MAIN GENERATION COMPONENTS
AUTO TRANSFORMER
IDENTIFICATIONFIN: 15XN1 (15XN2)
LOCATIONZONE: 212
COMPONENT DESCRIPTIONA 115/26 V single phase autotransformer, supplyingnormal 26V/400Hz sub-busbars (131XP-A and 231XP-A),is connected to each main busbar (AC BUS1: 1XP and ACBUS2: 2XP)
TMUELAN01-T03 LEVEL 3
EFFECTIVITY 24-22-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 166EFFECTIVITYALL
TMUELAN01-P03 LEVEL 3
AC GENERATION - MAIN GENERATION COMPONENTS - AUTO TRANSFORMER
EFFECTIVITY 24-22-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 167EFFECTIVITYALL
AC GENERATION - MAIN GENERATION COMPONENTS
6 HOLE CURRENT TRANSFORMER
IDENTIFICATIONFIN: 41XU1 (41XU2)
LOCATIONZONE: 131
COMPONENT DESCRIPTIONThe 6 hole Current Transformer assembly contains sixtoroidal transformers, one for each of the parallelpower feeder cables.The 2 Current Transformers foreach phase are connected in electrical opposition toeach other within the Current Transformer assembly.The6 hole Current Transformer assembly senses openparallel feeders.
TMUELAN01-T04 LEVEL 3
EFFECTIVITY 24-22-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 168EFFECTIVITYALL
AC GENERATION - MAIN GENERATION COMPONENTS - 6 HOLE CURRENT TRANSFORMER
TMUELAN01-P04 LEVEL 3
EFFECTIVITY 24-22-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 169EFFECTIVITYALL
AC GENERATION - MAIN GENERATION COMPONENTS
3 HOLE CURRENT TRANSFORMER
IDENTIFICATIONFIN: 42XU
LOCATIONZONE: 212
COMPONENT DESCRIPTIONThe 3 hole Current Transformer assembly contains threetoroidal transformers: one for each of the power feedercables. The line Current Transformers work inconjunction with the generator Current Transformer toprovide differential current, fault sensing andovercurrent sensing
TMUELAN01-T05 LEVEL 3
EFFECTIVITY 24-22-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 170EFFECTIVITYALL
AC GENERATION - MAIN GENERATION COMPONENTS - 3 HOLE CURRENT TRANSFORMER
TMUELAN01-P05 LEVEL 3
EFFECTIVITY 24-22-00 Page 11May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 171EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELAN01 LEVEL 3
EFFECTIVITY 24-22-00 Page 12May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 172EFFECTIVITYALL
24 - ELECTRICAL POWER
24-23-00 AC GENERATION - AC AUXILIARYGENERATION D/O
CONTENTS:GeneratorGenerator Control Unit SupplyGenerator Operation ControlGenerator MonitoringGenerator ResetGenerator Temperature MonitoringSelf Examination
TMUELAO02 LEVEL 3
EFFECTIVITY 24-23-00 Page 1Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 173EFFECTIVITYALL
AC GENERATION - AC AUXILIARY GENERATION D/O
GENERATOR
The APU generator operation principle and the outputcharacteristics are identical to those of the IDGgenerator.The APU directly drives the APU generator at a nominal24000 RPM constant speed.The cooling circuit is common to the APU and to thegenerator.
GENERATOR CONTROL UNIT SUPPLY
The Generator Control Unit supply operation principleis identical to that of the AC Main generation.
GENERATOR OPERATION CONTROL
The generator is controlled by the APU generationpushbutton. When pressed in, if the APU speed is highenough, the generator is energized.When the APU is available, the APU Ready signal allowsthe Power Relay to be energized via the protectionmodule (Delivered Parameters correct). The APUGenerator Line Contactor (GLC 3) is energized througha priority logic (GLC, BTC, EPC logic).
GENERATOR MONITORING
The generator monitoring operation is identical tothat of the IDG generator.The monitoring system (FAULT light and ECAM system)is inhibited as long as the APU is not available.
GENERATOR RESET
When the APU generator pushbutton is released out aftera fault detection, the Generator Control Unit is reset.The Generator Control Relay (GCR) and the Power Readyrelay (PR) are reset.
GENERATOR TEMPERATURE MONITORING
A temperature sensor is incorporated in the auxiliarygenerator to monitor the oil outlet temperature.The temperature sensor is connected to the ElectronicControl Box (ECB) to shut down the APU in case ofexcessive temperature.
TMUELAO02-T01 LEVEL 3
EFFECTIVITY 24-23-00 Page 2Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 174EFFECTIVITYALL
AC GENERATION - AC AUXILIARY GENERATION D/OTMUELAO02-P01 LEVEL 3
EFFECTIVITY 24-23-00 Page 3Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 175EFFECTIVITYALL
SELF EXAMINATION
When does the APU GEN FAULT light come on?A - When the APU is shut down.B - When a fault is detected.C - Both.
Where is the APU generator oil outlet temperaturesignal sent to?
A - To the ECB.B - Directly to the GCU.C - To the GCU through the ECB.
TMUELAO02 LEVEL 3
EFFECTIVITY 24-23-00 Page 4Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 176EFFECTIVITYALL
24 - ELECTRICAL POWER
24-23-00 AC GENERATION - AUXILIARYGENERATION COMPONENTS
CONTENTS:Generator Control Unit 3APU Line ContactorAPU GeneratorAPU Generator Substitution Kit
TMUELAQ01 LEVEL 3
EFFECTIVITY 24-23-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 177EFFECTIVITYALL
AC GENERATION - AUXILIARY GENERATION COMPONENTS
GENERATOR CONTROL UNIT 3
IDENTIFICATIONFIN: 1XS
LOCATIONZONE: 121
COMPONENT DESCRIPTIONThis 3 GCUs are identical and interchangeable. The GCUfunctions (GCU 1, 2 and GCU APU) are selected by pinprogramming.
TMUELAQ01-T01 LEVEL 3
EFFECTIVITY 24-23-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 178EFFECTIVITYALL
AC GENERATION - AUXILIARY GENERATION COMPONENTS - GENERATOR CONTROL UNIT 3
TMUELAQ01-P01 LEVEL 3
EFFECTIVITY 24-23-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 179EFFECTIVITYALL
AC GENERATION - AUXILIARY GENERATION COMPONENTS
APU LINE CONTACTOR
IDENTIFICATIONFIN: 3XS
LOCATIONZONE: 212
COMPONENT DESCRIPTIONIt is of the plug type.
TMUELAQ01-T02 LEVEL 3
EFFECTIVITY 24-23-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 180EFFECTIVITYALL
AC GENERATION - AUXILIARY GENERATION COMPONENTS - APU LINE CONTACTOR
TMUELAQ01-P02 LEVEL 3
EFFECTIVITY 24-23-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 181EFFECTIVITYALL
AC GENERATION - AUXILIARY GENERATION COMPONENTS
APU GENERATOR
IDENTIFICATIONFIN: 8XS
LOCATIONZONE: 316
COMPONENT DESCRIPTIONInput speed 24000 RPM.Weight: 22.32 kg [49.16 lbs]The APU gearbox provides the oil for cooling andlubrication of the generator.The cooling circuit is common to the APU and thegenerator.
TMUELAQ01-T03 LEVEL 3
EFFECTIVITY 24-23-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 182EFFECTIVITYALL
AC GENERATION - AUXILIARY GENERATION COMPONENTS - APU GENERATOR
TMUELAQ01-P03 LEVEL 3
EFFECTIVITY 24-23-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 183EFFECTIVITYALL
AC GENERATION - AUXILIARY GENERATION COMPONENTS
APU GENERATOR SUBSTITUTION KIT
With the APU generator removed and the replacementgenerator not available a substitution kit consistingof a cover assembly and a cable support assembly mustbe installed on the APU.
TMUELAQ01-T04 LEVEL 3
EFFECTIVITY 24-23-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 184EFFECTIVITYALL
AC GENERATION - AUXILIARY GENERATION COMPONENTS - APU GENERATOR SUBSTITUTION KIT
TMUELAQ01-P04 LEVEL 3
EFFECTIVITY 24-23-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 185EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELAQ01 LEVEL 3
EFFECTIVITY 24-23-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 186EFFECTIVITYALL
24 - ELECTRICAL POWER
24-24-00 AC GENERATION - EMERGENCYGENERATION D/O
CONTENTS:GeneratorCSM/G Control Unit SupplyGenerator Operation ControlGenerator MonitoringSelf Examination
TMUELAS02 LEVEL 3
EFFECTIVITY 24-24-00 Page 1Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 187EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION D/O
GENERATOR
The Constant Speed Motor/Generator consists of ahydraulic motor which drives a generator.The hydraulic motor is pressurized by the bluehydraulic system through an integrated solenoid valve.The hydraulic motor speed is regulated by a servovalve.The generator operation principle is identical to thatof the main or auxiliary generation. The generatoroutput characteristics are:
- three phase 115/200V. 400Hz (12000RPM)- output power: 5KVA continuously
CSM/G CONTROL UNIT SUPPLY
Battery 2 (during transient configuration) and thenthe Permanent Magnet Generator supplies the ConstantSpeed Motor/Generator control unit and the exciterfield through a voltage regulation module.The voltage regulation module maintains the Point OfRegulation (POR) at a nominal voltage value (115V).
TMUELAS02-T01 LEVEL 3
EFFECTIVITY 24-24-00 Page 2Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 188EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION D/OTMUELAS02-P01 LEVEL 3
EFFECTIVITY 24-24-00 Page 3Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 189EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION D/O
GENERATOR OPERATION CONTROL
As the Emergency AC generator parameters are correct,the Emergency Generator Line Contactor is supplied bythe Constant Speed Motor/Generator control unit.The Emergency AC generator has priority to supply theAC and DC ESSential Buses (Contactors 3XC1 and 3XC2are de-energized by relay 12XE).
TMUELAS02-T02 LEVEL 3
EFFECTIVITY 24-24-00 Page 4Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 190EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION D/O - GENERATOR OPERATION CONTROLTMUELAS02-P02 LEVEL 3
EFFECTIVITY 24-24-00 Page 5Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 191EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION D/O
GENERATOR MONITORING
The Constant Speed Motor/Generator operation ismonitored by the red FAULT light.The FAULT light activation is controlled by eitherBattery Charge Limiter (BCL1 or 2).During transient configuration or if the generator isfaulty, there is no ESS TR output, thus the fault lightcomes on.
TMUELAS02-T03 LEVEL 3
EFFECTIVITY 24-24-00 Page 6Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 192EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION D/O - GENERATOR MONITORINGTMUELAS02-P03 LEVEL 3
EFFECTIVITY 24-24-00 Page 7Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 193EFFECTIVITYALL
SELF EXAMINATION
With the Main Landing Gear not compressed, andafter AC Bus 1 and 2 failures, when does the RATand EMER GEN FAULT light come on?
A - When the static inverter is lost.B - When the AC and DC ESS buses are lost.C - When the ESS TR is lost.
When does the CSM/G supply the DC and AC ESS buses?A - When AC Bus 1 or 2 is lost.B - When the Emergency Generator parameters
are correct.C - As soon as BAT 2 is lost.
TMUELAS02 LEVEL 3
EFFECTIVITY 24-24-00 Page 8Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 194EFFECTIVITYALL
24 - ELECTRICAL POWER
24-24-00 EMERGENCY ELECTRICAL POWER LOGICDESCRIPTION
CONTENTS:Emergency Generation Automatic OperationEmergency Generation Manual Operation In FlightEmergency Generation Manual Operation On GroundEmergency Generator TestSelf Examination
TMUELE502 LEVEL 1
EFFECTIVITY 24-24-00 Page 1Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 195EFFECTIVITYALL
EMERGENCY ELECTRICAL POWER LOGIC DESCRIPTION
EMERGENCY GENERATION AUTOMATIC OPERATION
If AC BUS 1 and 2 are lost above a given airspeed(100Kts), the Ram Air Turbine will extendautomatically.
As the AC generator is not yet available, the AC ESSBUS and DC ESS BUS are respectively supplied by theSTATIC INVERTER and BATTERY 2.
The activation of the emergency generator via the bluehydraulic system takes place only if the landing gearis not compressed.When the EMER GEN is available, it supplies the AC ESSBUS and via ESS TR, the DC ESS BUS.
As the nose landing gear is now compressed, the AC ESSBUS and DC ESS BUS are respectively supplied by theSTATIC INVERTER and the BATTERY 2.
TMUELE502-T01 LEVEL 1
EFFECTIVITY 24-24-00 Page 2Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 196EFFECTIVITYALL
EMERGENCY GENERATION AUTOMATIC OPERATIONTMUELE502-P01 LEVEL 1
EFFECTIVITY 24-24-00 Page 3Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 197EFFECTIVITYALL
EMERGENCY ELECTRICAL POWER LOGIC DESCRIPTION
EMERGENCY GENERATION MANUAL OPERATION IN FLIGHT
If AC BUS 1 and 2 are lost and the Ram Air Turbinedoes not extend, FAULT light comes on red on the EMERELEC PWR panel. The Ram Air Turbine must be manually extended to powerthe emergency generator. This is done by pressing theguarded MAN ON pushbutton on the emergency electricalpower panel.
TMUELE502-T02 LEVEL 1
EFFECTIVITY 24-24-00 Page 4Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 198EFFECTIVITYALL
EMERGENCY GENERATION AUTOMATIC OPERATION IN FLIGHTTMUELE502-P02 LEVEL 1
EFFECTIVITY 24-24-00 Page 5Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 199EFFECTIVITYALL
EMERGENCY ELECTRICAL POWER LOGIC DESCRIPTION
EMERGENCY GENERATION MANUAL OPERATION ON GROUND
WARNING:If the MAN ON pushbutton is pressed in, the RAT extends,even in cold aircraft.
TMUELE502-T03 LEVEL 1
EFFECTIVITY 24-24-00 Page 6Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 200EFFECTIVITYALL
EMERGENCY GENERATION MANUAL OPERATION ON GROUNDTMUELE502-P03 LEVEL 1
EFFECTIVITY 24-24-00 Page 7Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 201EFFECTIVITYALL
EMERGENCY ELECTRICAL POWER LOGIC DESCRIPTION
Emergency Generator Test
The emergency generator operational test is carriedout to check the emergency generator parameters andthe corresponding network supply.For test purposes the blue hydraulic system must bepressurized thanks to the BLUE PUMP OVRD pushbuttonand the EMER GEN TEST pushbutton must be held pressedin.As the Emergency generator is connected, check thegenerator parameters on the ECAM display.
TMUELE502-T04 LEVEL 1
EFFECTIVITY 24-24-00 Page 8Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 202EFFECTIVITYALL
EMERGENCY GENERATOR TESTTMUELE502-P04 LEVEL 1
EFFECTIVITY 24-24-00 Page 9Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 203EFFECTIVITYALL
SELF EXAMINATION
After activation of the blue pump what happensduring the EMER GEN test ?
A - The Ram Air Turbine is extended.B - The emergency generator comes on line.C - The RAT is extended and the emergency
generator comes on line.
On ground, in a cold aircraft configuration whatdoes the activation of the RAT & EMER GEN MAN ONpushbutton cause ?
A - Ram Air Turbine extensionB - NothingC - Emergency generator activation
TMUELE502 LEVEL 1
EFFECTIVITY 24-24-00 Page 10Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 204EFFECTIVITYALL
24 - ELECTRICAL POWER
24-24-00 AC GENERATION - RAM AIR TURBINEACTIVATION
CONTENTS:Automatic ActivationManual ActivationManual Activation From Hydraulic PanelSelf Examination
TMUELAR02 LEVEL 3
EFFECTIVITY 24-24-00 Page 1Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 205EFFECTIVITYALL
AC GENERATION - RAM AIR TURBINE ACTIVATION
AUTOMATIC ACTIVATION
In flight, when the two AC main buses are lost andwhen speed is higher than 100 knots, Ram Air Turbinesolenoid 1 is energized by HOT BATTERY BUS 1 and theRam Air Turbine (RAT) extends automatically.In addition, the CSM/G Control Unit activates the CSM/Gsolenoid valve using battery 2 and the generator startsrunning.After relay 22XE time delay, RAT solenoid 1 isde-energized and the Constant Speed Motor/Generatorsolenoid valve is supplied by the Permanent MagnetGenerator (PMG).
TMUELAR02-T01 LEVEL 3
EFFECTIVITY 24-24-00 Page 2Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 206EFFECTIVITYALL
AC GENERATION - RAM AIR TURBINE ACTIVATION - AUTOMATIC ACTIVATIONTMUELAR02-P01 LEVEL 3
EFFECTIVITY 24-24-00 Page 3Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 207EFFECTIVITYALL
AC GENERATION - RAM AIR TURBINE ACTIVATION
MANUAL ACTIVATION
When the MAN ON pushbutton is pressed, RAT solenoid 2is energized by battery 2 and the RAT extends.In addition, the CSM/G Control Unit activates the CSM/Gsolenoid valve using battery 2 and the generator startsrunning.When the MAN ON pushbutton is released out, RATsolenoid 2 is de-energized.The CSM/G solenoid valve is supplied by the PMG.NOTE: the RAT manual activation function is only used
in case of CSM/G automatic control logic failure.
TMUELAR02-T02 LEVEL 3
EFFECTIVITY 24-24-00 Page 4Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 208EFFECTIVITYALL
AC GENERATION - RAM AIR TURBINE ACTIVATION - MANUAL ACTIVATIONTMUELAR02-P02 LEVEL 3
EFFECTIVITY 24-24-00 Page 5Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 209EFFECTIVITYALL
AC GENERATION - RAM AIR TURBINE ACTIVATION
MANUAL ACTIVATION FROM HYDRAULIC PANEL
The RAT MAN ON pushbutton on the Blue Hydraulic Panelenables the activation of the RAT for hydraulic powersupply only.Solenoid 1 is then supplied by HOT BAT BUS 1.
TMUELAR02-T03 LEVEL 3
EFFECTIVITY 24-24-00 Page 6Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 210EFFECTIVITYALL
AC GENERATION - RAM AIR TURBINE ACTIVATION - MANUAL ACTIVATION FROM HYDRAULIC PANELTMUELAR02-P03 LEVEL 3
EFFECTIVITY 24-24-00 Page 7Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 211EFFECTIVITYALL
SELF EXAMINATION
How is the RAT extension system controlled?A - By means of two solenoids energized at
the same time.B - By means of two solenoids.C - By means of one solenoid only.
What are the RAT solenoids supplied by?A - Battery or Hot Bat Bus.B - DC Bat Bus.C - DC Bus 1 or 2.
TMUELAR02 LEVEL 3
EFFECTIVITY 24-24-00 Page 8Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 212EFFECTIVITYALL
24 - ELECTRICAL POWER
24-24-00 AC GENERATION - CONSTANT SPEEDMOTOR/GENERATOR CONTROL UNIT D/O
CONTENTS:Generator ControlSpeed RegulationVoltage RegulationGenerator MonitoringBITESelf Examination
TMUELAT02 LEVEL 3
EFFECTIVITY 24-24-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 213EFFECTIVITYALL
AC GENERATION - CONSTANT SPEED MOTOR/GENERATOR CONTROL UNIT D/O
CONSTANT SPEED MOTOR
The automatic control logic being set, the GeneratorControl Unit (GCU) internal 28VDC bus is supplied bybattery 2 through relay K3.Relay K1 is then energized, allowing the solenoidcontrol valve to be supplied by the internal bus (stillon BAT2). Relay K3 is held closed by the GCU internalsupply via relay K2 and the time delay openingtransistor.When the emergency generator parameters are correct(voltage and frequency above UV and UF threshold) orafter 10 seconds (CSM/G start phase), relay K2 closes.The Generator Line Contactor (GLC) closes and relayK3 is de-energized, allowing the Solenoid Control Valvepower supply change over from battery 2 to thePermanent Magnet Generator(PMG).The CSM/G can also be started manually via the MAN ONpushbutton.
TMUELAT02-T01 LEVEL 3
EFFECTIVITY 24-24-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 214EFFECTIVITYALL
AC GENERATION - CONSTANT SPEED MOTOR/GENERATOR CONTROL UNIT D/O - GENERATOR CONTROLTMUELAT02-P01 LEVEL 3
EFFECTIVITY 24-24-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 215EFFECTIVITYALL
AC GENERATION - CONSTANT SPEED MOTOR/GENERATOR CONTROL UNIT D/O
SPEED REGULATION
The servovalve, which regulates the hydraulic motorspeed, is electrically controlled by the speedregulation module of the control unit.The GCU maintains the CSM/G at constant speed by:
- monitoring the frequency of the PMG and- comparing it with a quartz crystal controlledreference.
The resulting error signal is then used to control theCSM/G servo-valve to a more open or close position.
TMUELAT02-T02 LEVEL 3
EFFECTIVITY 24-24-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 216EFFECTIVITYALL
AC GENERATION - CONSTANT SPEED MOTOR/GENERATOR CONTROL UNIT D/O - SPEED REGULATIONTMUELAT02-P02 LEVEL 3
EFFECTIVITY 24-24-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 217EFFECTIVITYALL
AC GENERATION - CONSTANT SPEED MOTOR/GENERATOR CONTROL UNIT D/O
VOLTAGE REGULATION
The PMG supplies the exciter field through a voltageregulation module.The GCU maintains the CSM/G output voltage constantby monitoring the voltage at the Point Of Regulation(POR).The output voltage is compared to 115V reference andused as an operational error to regulate the fieldcurrent.
TMUELAT02-T03 LEVEL 3
EFFECTIVITY 24-24-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 218EFFECTIVITYALL
AC GENERATION - CONSTANT SPEED MOTOR/GENERATOR CONTROL UNIT D/O - VOLTAGE REGULATIONTMUELAT02-P03 LEVEL 3
EFFECTIVITY 24-24-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 219EFFECTIVITYALL
AC GENERATION - CONSTANT SPEED MOTOR/GENERATOR CONTROL UNIT D/O
GENERATOR MONITORING
The protection module protects the network and thegenerator by controlling the associated GLC, thegenerator field current and the solenoid control valve.The protections are the following:
- Over/Under voltage.- Over/Under frequency.- Shorted PMG.- Fast overspeed shutdown.
When a failure is detected, relay K1 opens tode-energize the solenoid control valve: the generatorstops operating.The MAN ON pushbutton must be pressed in to reset theprotection module and to recover the Solenoid Controlvalve power supply.
TMUELAT02-T04 LEVEL 3
EFFECTIVITY 24-24-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 220EFFECTIVITYALL
AC GENERATION - CONSTANT SPEED MOTOR/GENERATOR CONTROL UNIT D/O - GENERATOR MONITORINGTMUELAT02-P04 LEVEL 3
EFFECTIVITY 24-24-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 221EFFECTIVITYALL
AC GENERATION - CONSTANT SPEED MOTOR/GENERATOR CONTROL UNIT D/O
BITE
The CSM/G GCU provides a type 3 BITE system.The CSM/G GCU is linked to the CFDIU by two discretelinks (type 3 system) and has a simplified and limitedinteractive dialog. Tests can be launched from the GCUEMER page on the MCDU.
TMUELAT02-T05 LEVEL 3
EFFECTIVITY 24-24-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 222EFFECTIVITYALL
AC GENERATION - CONSTANT SPEED MOTOR/GENERATOR CONTROL UNIT D/O - BITETMUELAT02-P05 LEVEL 3
EFFECTIVITY 24-24-00 Page 11May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 223EFFECTIVITYALL
SELF EXAMINATION
What is the solenoid control valve normallysupplied by when the Constant Speed Motor/Generatoris on line?
A - The CSM/G PMG.B - Battery 2.C - The DC BAT BUS.
What does the CSM/G control unit control when afault has been detected?
A - The solenoid control valve, the exciterfield and the GLC to off.
B - The exciter field to on, the GLC to offand the generator speed to low speed.
C - The solenoid control valve to off, theGLC to on, the exciter field to off.
TMUELAT02 LEVEL 3
EFFECTIVITY 24-24-00 Page 12May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 224EFFECTIVITYALL
24 - ELECTRICAL POWER
24-24-00 AC GENERATION - CSM/GOPERATIONAL TEST ELECTRICALCIRCUIT
CONTENTS:Test Pushbutton Pressed-InTest Pushbutton Released-Out
TMUELAV02 LEVEL 3
EFFECTIVITY 24-24-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 225EFFECTIVITYALL
AC GENERATION - CSM/G OPERATIONAL TEST ELECTRICAL CIRCUIT
TEST PUSHBUTTON PRESSED-IN
NOTE: the blue hydraulic system must be pressurized,AC BUS 1 and 2 must be supplied.
When the EMER GEN TEST pushbutton is pressed in, aloss of AC BUS 1 and AC BUS 2 and a speed higher than100 knots are simulated by energizing relay 16XE.Relay3PH is then energized, allowing relay 20XE to beenergized via relays 17XE and 18XE. The Constant SpeedMotor/Generator (CSM/G) CONTROL circuit is thensupplied from HOT BUS 703PP. This permits the VALVECONTROL circuit and the SOLENOID CONTROL VALVE to besupplied from BAT2. DC ESS SHED BUS supply isinterrupted by relay 21XE.Relay 22XE closes after the time delay and cuts theCSM/G CONTROL circuit supply from HOT BUS 703PP. TheSOLENOID CONTROL VALVE supply is then transfered fromBAT2 to the PMG through the VALVE CONTROL circuit.NOTE: RAT extension is inhibited by relay 30XE if 23XE
is released before 22XE closes.
TMUELAV02-T01 LEVEL 3
EFFECTIVITY 24-24-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 226EFFECTIVITYALL
AC GENERATION - CSM/G OPERATIONAL TEST ELECTRICAL CIRCUIT - TEST PUSHBUTTON PRESSED-INTMUELAV02-P01 LEVEL 3
EFFECTIVITY 24-24-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 227EFFECTIVITYALL
AC GENERATION - CSM/G OPERATIONAL TEST ELECTRICAL CIRCUIT
TEST PUSHBUTTON RELEASED-OUT
When the EMER GEN TEST pushbutton is released out,relay 16XE is de-energized. Relay 3PH is thende-energized, allowing the LGCIU1 signal to stop theCSM/G.
TMUELAV02-T02 LEVEL 3
EFFECTIVITY 24-24-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 228EFFECTIVITYALL
AC GENERATION - CSM/G OPERATIONAL TEST ELECTRICAL CIRCUIT - TEST PUSHBUTTON RELEASED-OUTTMUELAV02-P02 LEVEL 3
EFFECTIVITY 24-24-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 229EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELAV02 LEVEL 3
EFFECTIVITY 24-24-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 230EFFECTIVITYALL
24 - ELECTRICAL POWER
24-24-00 AC GENERATION - EMERGENCYGENERATION COMPONENTS
CONTENTS:Constant Speed Motor/GeneratorConstant Speed Motor/Generator Control UnitEmergency Generator Line ContactorContactor 15XEContactor 3XCAutotransformer
TMUELAX01 LEVEL 3
EFFECTIVITY 24-24-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 231EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS
CONSTANT SPEED MOTOR/GENERATOR
IDENTIFICATIONFIN: 8XE
LOCATIONZONE: 148
COMPONENT DESCRIPTIONThis unit includes a hydraulic motor powered by theblue hydraulic system.
- Output power of 5 KVA.- Output frequency 400 Hz.- Output voltage 115 VAC.- Weight : 9.05 Kg (19.96 lbs).
TMUELAX01-T01 LEVEL 3
EFFECTIVITY 24-24-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 232EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS - CONSTANT SPEED MOTOR/GENERATOR
TMUELAX01-P01 LEVEL 3
EFFECTIVITY 24-24-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 233EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS
CONSTANT SPEED MOTOR/GENERATOR CONTROL UNIT
IDENTIFICATIONFIN: 1XE
LOCATIONZONE: 125
COMPONENT DESCRIPTIONThis unit:
- controls the servo-valve excitation for speedregulation.
- controls the generator voltage.- protects the network and the generator bycontrolling line contactors.
TMUELAX01-T02 LEVEL 3
EFFECTIVITY 24-24-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 234EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS - CONSTANT SPEED MOTOR/GENERATOR CONTROLUNIT
TMUELAX01-P02 LEVEL 3
EFFECTIVITY 24-24-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 235EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS
EMERGENCY GENERATOR LINE CONTACTOR
IDENTIFICATIONFIN: 2XE
LOCATIONZONE: 125
COMPONENT DESCRIPTIONThis contactor, controlled by the CSM/G control unit,supplies the network in emergency conditions.
TMUELAX01-T03 LEVEL 3
EFFECTIVITY 24-24-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 236EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS - EMERGENCY GENERATOR LINE CONTACTOR
TMUELAX01-P03 LEVEL 3
EFFECTIVITY 24-24-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 237EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS
CONTACTOR 15XE
IDENTIFICATIONFIN: 15XE
LOCATIONZONE: 125
COMPONENT DESCRIPTIONIn emergency conditions, this contactor, located in106VU, allows the supply of AC ESSENTIAL Bus from theCSM/G.
TMUELAX01-T04 LEVEL 3
EFFECTIVITY 24-24-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 238EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS - CONTACTOR 15XE
TMUELAX01-P04 LEVEL 3
EFFECTIVITY 24-24-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 239EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS
CONTACTOR 3XC
IDENTIFICATIONFIN: 3XC
LOCATIONZONE: 125
COMPONENT DESCRIPTIONIn normal conditions, this contactor allows the supplyof AC ESS Bus by AC BUS1 and by AC BUS2 if AC BUS1 islost.
TMUELAX01-T05 LEVEL 3
EFFECTIVITY 24-24-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 240EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS - CONTACTOR 3XC
TMUELAX01-P05 LEVEL 3
EFFECTIVITY 24-24-00 Page 11May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 241EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS
AUTOTRANSFORMER
IDENTIFICATIONFIN: 5XH
LOCATIONZONE: 125
COMPONENT DESCRIPTIONA 115/26 V single phase autotransformer, supplying anessential 26V/400 Hz sub-busbar (431XP-A), isconnected to the essential busbar (AC ESS BUS, 4XP).
TMUELAX01-T06 LEVEL 3
EFFECTIVITY 24-24-00 Page 12May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 242EFFECTIVITYALL
AC GENERATION - EMERGENCY GENERATION COMPONENTS - AUTOTRANSFORMER
TMUELAX01-P06 LEVEL 3
EFFECTIVITY 24-24-00 Page 13May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 243EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELAX01 LEVEL 3
EFFECTIVITY 24-24-00 Page 14May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 244EFFECTIVITYALL
24 - ELECTRICAL POWER
24-28-00 AC GENERATION - STATIC INVERTERD/O
CONTENTS:GeneralEmergency Configuration (V above 100 Kts)Emergency Configuration (V between 50 and 100 Kts)Emergency Configuration (V below 50 Kts)MonitoringTestSelf Examination
TMUELBC01 LEVEL 3
EFFECTIVITY 24-28-00 Page 1Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 245EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O
GENERAL
A Static Inverter transforms the direct current frombattery 1 into a single phase alternating current.The Static Inverter characteristics are:
- 1 KVA nominal power.- 115V, 400Hz, single phase.
The Static Inverter is used in the following cases:- APU start (supply of fuel pump).- Ram Air Turbine deployment.- Engine start on battery (ignition).- Emergency configuration.
TMUELBC01-T01 LEVEL 3
EFFECTIVITY 24-28-00 Page 2Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 246EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O - GENERALTMUELBC01-P01 LEVEL 3
EFFECTIVITY 24-28-00 Page 3Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 247EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O
EMERGENCY CONFIGURATION (V above 100 Kts)
In this configuration the Constant SpeedMotor/Generator supplies the AC ESSential Bus and DCESSential Bus through the Essential Rectifier unit.The Static Inverter is not electrically supplied.
TMUELBC01-T02 LEVEL 3
EFFECTIVITY 24-28-00 Page 4Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 248EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O - EMERGENCY CONFIGURATION (V above 100 Kts)TMUELBC01-P02 LEVEL 3
EFFECTIVITY 24-28-00 Page 5Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 249EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O
EMERGENCY CONFIGURATION (V between 50 and 100 Kts)
In this configuration the Emergency Generator is nolonger connected to the aircraft network. The ACESSential Bus is supplied by the Static Inverter whichis supplied from battery 1.On the other hand, the DC ESSential Bus is directlysupplied by battery 2.The AC STATIC Inverter Bus is also supplied by theStatic Inverter. This bus is used for the APU fuelpump supply.The DC and AC SHED ESSential Buses (circuits PH andXH) are no longer supplied.
TMUELBC01-T03 LEVEL 3
EFFECTIVITY 24-28-00 Page 6Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 250EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O - EMERGENCY CONFIGURATION (V between 50 and 100 Kts)TMUELBC01-P03 LEVEL 3
EFFECTIVITY 24-28-00 Page 7Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 251EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O
EMERGENCY CONFIGURATION (V below 50 Kts)
In this configuration the AC ESSential Bus is no longerconnected to the Static Inverter.The DC ESS Bus and the AC STATIC INVerter Bus remainsupplied.
TMUELBC01-T04 LEVEL 3
EFFECTIVITY 24-28-00 Page 8Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 252EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O - EMERGENCY CONFIGURATION (V below 50 Kts)TMUELBC01-P04 LEVEL 3
EFFECTIVITY 24-28-00 Page 9Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 253EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O
MONITORING
Static Inverter faults are signalled to the BatteryCharge Limiter.The Battery Charge Limiter (BCL) memorizes the faultsas Class 1 failures, which will be displayed on theECAM upper display when the aircraft electrical networkis supplied.The following Static Inverter parameters aremonitored:
- overheat,- output/input overvoltage,- input undervoltage.
TMUELBC01-T05 LEVEL 3
EFFECTIVITY 24-28-00 Page 10Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 254EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O - MONITORINGTMUELBC01-P05 LEVEL 3
EFFECTIVITY 24-28-00 Page 11Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 255EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O
TEST
To perform the Static Inverter test, the EMER GEN TESTpushbutton is pressed in. This simulates an aircraftspeed above 50 knots.The Static Inverter parameters have to be checked onthe ECAM system.
TMUELBC01-T06 LEVEL 3
EFFECTIVITY 24-28-00 Page 12Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 256EFFECTIVITYALL
AC GENERATION - STATIC INVERTER D/O - TESTTMUELBC01-P06 LEVEL 3
EFFECTIVITY 24-28-00 Page 13Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 257EFFECTIVITYALL
SELF EXAMINATION
In emergency configuration with an aircraft speedbelow 50 kts, what is the condition of the aircraftelectrical network?
A - AC ESS BUS, DC ESS BUS and AC STATICINVERTER BUS are supplied.
B - DC ESS BUS, AC STATIC INVERTER BUS andDC BAT BUS are supplied.
C - AC ESS BUS, AC STATIC INVERTER BUS andDC BAT BUS are supplied.
To which computer is a static inverter fault signalsent to?
A - Ground Power Control Unit.B - Generator Control Unit.C - Battery Charge Limiter.
TMUELBC01 LEVEL 3
EFFECTIVITY 24-28-00 Page 14Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 258EFFECTIVITYALL
24 - ELECTRICAL POWER
24-28-00 AC GENERATION - STATIC INVERTERCOMPONENTS
CONTENTS:Static InverterContactor 2XBContactor 8PHContactor 8XH
TMUELBF01 LEVEL 3
EFFECTIVITY 24-28-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 259EFFECTIVITYALL
AC GENERATION - STATIC INVERTER COMPONENTS
STATIC INVERTER
IDENTIFICATIONFIN: 3XB
LOCATIONZONE: 126
COMPONENT DESCRIPTIONThis unit transforms the Direct Current from thebattery bus into a single phase 115V/400HZ AlternatingCurrent.
TMUELBF01-T01 LEVEL 3
EFFECTIVITY 24-28-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 260EFFECTIVITYALL
AC GENERATION - STATIC INVERTER COMPONENTS - STATIC INVERTER
TMUELBF01-P01 LEVEL 3
EFFECTIVITY 24-28-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 261EFFECTIVITYALL
AC GENERATION - STATIC INVERTER COMPONENTS
CONTACTOR 2XB
IDENTIFICATIONFIN: 2XB
LOCATIONZONE: 126
COMPONENT DESCRIPTIONThis contactor allows the supply of the static inverterfrom the BAT1.
TMUELBF01-T02 LEVEL 3
EFFECTIVITY 24-28-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 262EFFECTIVITYALL
AC GENERATION - STATIC INVERTER COMPONENTS - CONTACTOR 2XB
TMUELBF01-P02 LEVEL 3
EFFECTIVITY 24-28-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 263EFFECTIVITYALL
AC GENERATION - STATIC INVERTER COMPONENTS
CONTACTOR 8PH
IDENTIFICATIONFIN: 8PH
LOCATIONZONE: 125
COMPONENT DESCRIPTIONThis contactor allows the DC SHEDDABLE ESSENTIAL Busto be supplied.
TMUELBF01-T03 LEVEL 3
EFFECTIVITY 24-28-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 264EFFECTIVITYALL
AC GENERATION - STATIC INVERTER COMPONENTS - CONTACTOR 8PH
TMUELBF01-P03 LEVEL 3
EFFECTIVITY 24-28-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 265EFFECTIVITYALL
AC GENERATION - STATIC INVERTER COMPONENTS
CONTACTOR 8XH
IDENTIFICATIONFIN: 8XH
LOCATIONZONE: 125
COMPONENT DESCRIPTIONWhen closed, this contactor allows the AC ESSENTIALSHEDDABLE Bus to be supplied by the AC ESSENTIAL Bus.
TMUELBF01-T04 LEVEL 3
EFFECTIVITY 24-28-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 266EFFECTIVITYALL
AC GENERATION - STATIC INVERTER COMPONENTS - CONTACTOR 8XH
TMUELBF01-P04 LEVEL 3
EFFECTIVITY 24-28-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 267EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBF01 LEVEL 3
EFFECTIVITY 24-28-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 268EFFECTIVITYALL
24 - ELECTRICAL POWER
24-25-00 AC GENERATION - AC ESSENTIAL BUSSWITCHING
CONTENTS:Normal ConfigurationAC Bus 1 LossAC Bus 1 And 2 LossSelf Examination
TMUELAW02 LEVEL 3
EFFECTIVITY 24-25-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 269EFFECTIVITYALL
AC GENERATION - AC ESSENTIAL BUS SWITCHING
NORMAL CONFIGURATION
In the normal configuration, the aircraft electricalnetwork is normally supplied and the AC ESSential Busis directly connected to AC Bus 1.
TMUELAW02-T01 LEVEL 3
EFFECTIVITY 24-25-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 270EFFECTIVITYALL
AC GENERATION - AC ESSENTIAL BUS SWITCHING - NORMAL CONFIGURATION
TMUELAW02-P01 LEVEL 3
EFFECTIVITY 24-25-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 271EFFECTIVITYALL
AC GENERATION - AC ESSENTIAL BUS SWITCHING
AC BUS 1 LOSS
In this configuration, the AC ESSential Bus is nolonger supplied.When the AC ESS FEED pushbutton is released out, theAC ESSential Bus supply is recovered from AC Bus 2.The FAULT light goes off and the white ALTN light comeson.
TMUELAW02-T02 LEVEL 3
EFFECTIVITY 24-25-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 272EFFECTIVITYALL
AC GENERATION - AC ESSENTIAL BUS SWITCHING - AC BUS 1 LOSS
TMUELAW02-P02 LEVEL 3
EFFECTIVITY 24-25-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 273EFFECTIVITYALL
AC GENERATION - AC ESSENTIAL BUS SWITCHING
AC BUS 1 AND 2 LOSS
In this configuration, the AC Emergency generator isconnected to the AC ESSential Bus.The ESS TR is supplied.
TMUELAW02-T03 LEVEL 3
EFFECTIVITY 24-25-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 274EFFECTIVITYALL
AC GENERATION - AC ESSENTIAL BUS SWITCHING - AC BUS 1 AND 2 LOSS
TMUELAW02-P03 LEVEL 3
EFFECTIVITY 24-25-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 275EFFECTIVITYALL
SELF EXAMINATION
In the normal configuration, which of the followingsupplies the AC ESS Bus?
A - AC Bus 2.B - Emerg. Generator.C - AC Bus 1.
What happens with the aircraft electrical networknormally supplied, and the AC ESS FEED pushbuttonreleased out (ALTN)?
A - AC ESS Bus is supplied by the EMERG GEN.B - AC ESS Bus is supplied by AC Bus 1.C - AC ESS Bus is supplied by AC Bus 2.
TMUELAW02 LEVEL 3
EFFECTIVITY 24-25-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 276EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 AC GENERATION - FUEL PUMPSELECTRICAL POWER SUPPLY IN SMOKECONFIGURATION
CONTENTS:Normal Electrical SupplySmoke WarningEMER ELEC GEN 1 LINE OFFEMER ELEC PWR MAN ONGEN 2 OFF
TMUELE802 LEVEL 1
EFFECTIVITY 24-00-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 277EFFECTIVITYALL
AC GENERATION - FUEL PUMPS ELECTRICAL POWER SUPPLY IN SMOKE CONFIGURATION
NORMAL ELECTRICAL SUPPLY
Here is the normal electrical supply of the wing fuelpumps. Left pump 1 and right pump 1 are supplied byAC BUS 1.
TMUELE802-T01 LEVEL 1
EFFECTIVITY 24-00-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 278EFFECTIVITYALL
AC GENERATION - FUEL PUMPS ELECTRICAL POWER SUPPLY IN SMOKE CONFIGURATION - NORMALELECTRICAL SUPPLY
TMUELE802-P01 LEVEL 1
EFFECTIVITY 24-00-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 279EFFECTIVITYALL
AC GENERATION - FUEL PUMPS ELECTRICAL POWER SUPPLY IN SMOKE CONFIGURATION
SMOKE WARNING
If an avionics smoke warning occurs and smoke isconfirmed, several actions have to be taken by thecockpit crew concerning mainly the ventilation andcommunication systems.If the smoke warning remains 5mn after actions on theventilation and communication systems, the followingprocedure must be applied.
TMUELE802-T02 LEVEL 1
EFFECTIVITY 24-00-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 280EFFECTIVITYALL
AC GENERATION - FUEL PUMPS ELECTRICAL POWER SUPPLY IN SMOKE CONFIGURATION - SMOKE WARNINGTMUELE802-P02 LEVEL 1
EFFECTIVITY 24-00-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 281EFFECTIVITYALL
AC GENERATION - FUEL PUMPS ELECTRICAL POWER SUPPLY IN SMOKE CONFIGURATION
1) EMER ELEC GEN 1 LINE OFF
GEN 1 LINE contactor opens. GEN 1 remains energizedand supplies one fuel pump in each wing tank. AC BUS1 is supplied by GEN 2 through Bus Tie Contactors.
TMUELE802-T03 LEVEL 1
EFFECTIVITY 24-00-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 282EFFECTIVITYALL
AC GENERATION - FUEL PUMPS ELECTRICAL POWER SUPPLY IN SMOKE CONFIGURATION - 1) EMER ELECGEN 1 LINE OFF
TMUELE802-P03 LEVEL 1
EFFECTIVITY 24-00-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 283EFFECTIVITYALL
AC GENERATION - FUEL PUMPS ELECTRICAL POWER SUPPLY IN SMOKE CONFIGURATION
2) EMER ELEC PWR MAN ON
The RAT is extended and the emergency generator isconnected to the aircraft network by its control unit,when the parameters are correct. The emergencygenerator then supplies the AC ESS bus and DC ESS busthrough ESS TR.
TMUELE802-T04 LEVEL 1
EFFECTIVITY 24-00-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 284EFFECTIVITYALL
AC GENERATION - FUEL PUMPS ELECTRICAL POWER SUPPLY IN SMOKE CONFIGURATION - 2) EMER ELECPWR MAN ON
TMUELE802-P04 LEVEL 1
EFFECTIVITY 24-00-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 285EFFECTIVITYALL
AC GENERATION - FUEL PUMPS ELECTRICAL POWER SUPPLY IN SMOKE CONFIGURATION
3) GEN 2 OFF
When EMER GEN AVAIL: GEN 2 OFF
Note: Before L/G extension, GEN 2 and EMER ELEC GEN 1 LINE must to be set to ON.
TMUELE802-T05 LEVEL 1
EFFECTIVITY 24-00-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 286EFFECTIVITYALL
TMUELE802-P05 LEVEL 1
AC GENERATION - FUEL PUMPS ELECTRICAL POWER SUPPLY IN SMOKE CONFIGURATION - 3) GEN2 OFF
EFFECTIVITY 24-00-00 Page 11May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 287EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELE802 LEVEL 1
EFFECTIVITY 24-00-00 Page 12May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 288EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 AC GENERATION - AC/DC SHEDDABLEBUS SUPPLY
CONTENTS:Normal ConfigurationEmergency ConfigurationCabin System Shedding
TMUELBE02 LEVEL 3
EFFECTIVITY 24-00-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 289EFFECTIVITYALL
AC GENERATION - AC/DC SHEDDABLE BUS SUPPLY
NORMAL CONFIGURATION
The AC and DC Sheddable buses are supplied by thecorresponding Essential buses.
TMUELBE02-T01 LEVEL 3
EFFECTIVITY 24-00-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 290EFFECTIVITYALL
AC GENERATION - AC/DC SHEDDABLE BUS SUPPLY - NORMAL CONFIGURATION
TMUELBE02-P01 LEVEL 3
EFFECTIVITY 24-00-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 291EFFECTIVITYALL
AC GENERATION - AC/DC SHEDDABLE BUS SUPPLY
EMERGENCY CONFIGURATION
In emergency configuration and CSM/G not available theStatic Inverter supplies the AC electrical system.The ESS Sheddable buses are no longer supplied duringStatic Inverter operation (relays 2XB and 6XBenergized).The AC and DC sheddable buses are also disconnectedduring a CSM/G operational test. (relays 16XE and 21XErelays).
TMUELBE02-T02 LEVEL 3
EFFECTIVITY 24-00-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 292EFFECTIVITYALL
TMUELBE02-P02 LEVEL 3
AC GENERATION - AC/DC SHEDDABLE BUS SUPPLY - EMERGENCY CONFIGURATION
EFFECTIVITY 24-00-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 293EFFECTIVITYALL
AC GENERATION - AC/DC SHEDDABLE BUS SUPPLY
CABIN SYSTEM SHEDDING
AC and DC sheddable buses are installed in panels 120VUand 2000VU for cabin related systems.All sheddable buses are off in single generatoroperation (10XA de-energized).Only the DC buses are shed in single TR operation (1PC2energized).If the GALY & CAB p/b (2XA) is released all these busesand all galleys are shed.
TMUELBE02-T03 LEVEL 3
EFFECTIVITY 24-00-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 294EFFECTIVITYALL
TMUELBE02-P03 LEVEL 3
AC GENERATION - AC/DC SHEDDABLE BUS SUPPLY - CABIN SYSTEM SHEDDING
EFFECTIVITY 24-00-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 295EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBE02 LEVEL 3
EFFECTIVITY 24-00-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 296EFFECTIVITYALL
24 - ELECTRICAL POWER
24-40-00 EXTERNAL POWER - GENERALDESCRIPTION
CONTENTS:Normal ParametersAbnormal ParametersSelf Examination
TMUELAY01 LEVEL 2
EFFECTIVITY 24-40-00 Page 1Nov 30/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 297EFFECTIVITYALL
EXTERNAL POWER - GENERAL DESCRIPTION
The aircraft network can be supplied by a Ground PowerUnit connected to an external receptacle locatedforward of the Nose Landing Gear well.
NORMAL PARAMETERS
If the External Power parameters are correct, theindicator lights on the external power receptacle andthe EXTERNAL POWER AVAILABLE light on the cockpitoverhead panel come on.The Ground Power parameters are monitored by the GroundPower Control Unit (GPCU) which activates the indicatorlights. With such indications the Ground Cart cansupply the aircraft network.As soon as the External Power pushbutton is pressedin, the Ground Power Control Unit closes the ExternalPower Contactor to supply the aircraft electricalnetwork.The Bus Tie Contactors (BTC 1 and BTC 2) close onlyif no engine generators are on line.
ABNORMAL PARAMETERS
If any external power parameter is not correct, theindicator lights stay off.The external power cannot be connected to the aircraftnetwork.The detection of a GPCU fault causes the EPC to open.
TMUELAY01-T01 LEVEL 2
EFFECTIVITY 24-40-00 Page 2Nov 30/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 298EFFECTIVITYALL
EXTERNAL POWER - GENERAL DESCRIPTION
TMUELAY01-P01 LEVEL 2
EFFECTIVITY 24-40-00 Page 3Nov 30/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 299EFFECTIVITYALL
SELF EXAMINATION
With the engine generators on line, what does theEXT PWR ON light indicate when lit?
A - The external ground cart is supplyingthe AC BUS 1 and 2.
B - The External Power Contactor iscontrolled to close.
C - The external ground cart is supplyingthe AC/DC ground service buses.
What does the EXT PWR AVAIL light indicate when lit?A - The Ground Power Control Unit has
tripped the external ground cart.B - The external ground cart is connected to
the aircraft network.C - The external ground cart can be
connected to the aircraft network.
TMUELAY01 LEVEL 2
EFFECTIVITY 24-40-00 Page 4Nov 30/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 300EFFECTIVITYALL
24 - ELECTRICAL POWER
24-41-00 EXTERNAL POWER - SYSTEM D/O
CONTENTS:Ground CartOperation ControlProtectionSelf Examination
TMUELAZ02 LEVEL 2
EFFECTIVITY 24-41-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 301EFFECTIVITYALL
EXTERNAL POWER - SYSTEM D/O
GROUND CART
The Ground Cart is plugged into the aircraft by meansof a standard 6 pin connector.
TMUELAZ02-T01 LEVEL 2
EFFECTIVITY 24-41-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 302EFFECTIVITYALL
EXTERNAL POWER - SYSTEM D/O - GROUND CART
TMUELAZ02-P01 LEVEL 2
EFFECTIVITY 24-41-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 303EFFECTIVITYALL
EXTERNAL POWER - SYSTEM D/O
OPERATION CONTROL (1)
With the Ground Cart running and switched on, theGround Power Control Unit allows the activation of theindicator lights through the Pin Monitoring Relay andthe Power Ready relay.
TMUELAZ02-T02 LEVEL 2
EFFECTIVITY 24-41-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 304EFFECTIVITYALL
EXTERNAL POWER - SYSTEM D/O - OPERATION CONTROL (1)
TMUELAZ02-P02 LEVEL 2
EFFECTIVITY 24-41-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 305EFFECTIVITYALL
EXTERNAL POWER - SYSTEM D/O
OPERATION CONTROL (2)
The External Power Contactor is energized through aBus Tie Contactor/Generator Line Contactor logic, bypressing the External Power pushbutton.In the cockpit, the EXT PWR AVAIL light goes off aswell as the NOT IN USE light on the external powerreceptacle.
TMUELAZ02-T03 LEVEL 2
EFFECTIVITY 24-41-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 306EFFECTIVITYALL
EXTERNAL POWER - SYSTEM D/O - OPERATION CONTROL (2)
TMUELAZ02-P03 LEVEL 2
EFFECTIVITY 24-41-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 307EFFECTIVITYALL
EXTERNAL POWER - SYSTEM D/O
PROTECTION
In case of Ground Cart malfunction, the ProtectionModule integrated in the Ground Power Control Unittrips the Power Ready relay which opens the ExternalPower Contactor.In the same way, a faulty Ground Cart cannot beconnected to the aircraft network. In this case, thereis no indication at all.
TMUELAZ02-T04 LEVEL 2
EFFECTIVITY 24-41-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 308EFFECTIVITYALL
EXTERNAL POWER - SYSTEM D/O - PROTECTION
TMUELAZ02-P04 LEVEL 2
EFFECTIVITY 24-41-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 309EFFECTIVITYALL
SELF EXAMINATION
The Ground Cart is running and switched on, the EXTPWR pushbutton is pressed in and there is noindication. What does that configuration mean?
A - The GPCU is supplied and the EPC is open.B - The GPCU is not supplied and the EPC is
open.C - The GPCU is supplied and the EPC is
closed.
What is the indication on the external powerreceptacle when the ground cart is connected to theaircraft network?
A - NOT IN USE light ON and AVAIL light ON.B - NOT IN USE light OFF and AVAIL light ON.C - NOT IN USE light OFF and AVAIL light OFF.
TMUELAZ02 LEVEL 2
EFFECTIVITY 24-41-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 310EFFECTIVITYALL
24 - ELECTRICAL POWER
24-41-00 EXTERNAL POWER - GROUND POWERCONTROL UNIT (GPCU) D/O
CONTENTS:SupplyMonitoringBITESelf Examination
TMUELBA01 LEVEL 3
EFFECTIVITY 24-41-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 311EFFECTIVITYALL
EXTERNAL POWER - GROUND POWER CONTROL UNIT (GPCU) D/O
SUPPLY
The Ground Power Control Unit is supplied by the GroundCart through the External Power receptacle andanalyses the voltage inputs.The Pin Monitoring Relay (PMR) is energized under thefollowing conditions:
- Ground Cart plugged in and running (voltage atpin E between 5 and 42 volts).
- and Ground Cart switched ON (voltage at pin Fbelow 42 volts and AC voltage at pins A, B andC within the limits).
If the delivered parameters are correct, the GroundPower Control Unit allows the External Power Contactorto be controlled.Two conditions must be fulfilled to energize the PowerReady relay (PR):
- valid EP (External Power) Interlock.- and delivered parameters within the limits.
MONITORING
The Ground Power Control Unit monitors the AC and DCparameters.AC protections are:
- over/under voltage.- over/under frequency.- Incorrect Phase Sequence (IPS).
DC protection is provided by External Power Receptaclepin voltage monitoring.The protection system also includes a GPCU InternalFault detection device.
BITE
The Ground Power Control Unit contains an internalBITE system to help in system trouble-shooting. TheBITE system detects and isolates active and passivefailures.The BITE system consists of two sections:
- operational BITE.- maintenance BITE.
The operational BITE identifies the protection,analyses the conditions and determines the faultorigin.The maintenance BITE completes the operational BITEand performs a self test to provide an indication ofsystem integrity in ground mode only.A Class 2 failure signal is sent to the ElectricalGeneration Interface Unit in order to display GroundPower Control Unit message on the ECAM status page.The CFDS class 2 message is labelled as:IDG 1 (2) HIGH DELTA TEMPTo enable the 3 Generator Control Units to dialoguewith the Centralized Fault Display Interface Unit(CFDIU) through the Ground Power Control Unit (GPCU),the GPCU receives a back-up supply from the DC BAT BUS(301PP).
TMUELBA01-T01 LEVEL 3
EFFECTIVITY 24-41-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 312EFFECTIVITYALL
EXTERNAL POWER - GROUND POWER CONTROL UNIT (GPCU) D/O
TMUELBA01-P01 LEVEL 3
EFFECTIVITY 24-41-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 313EFFECTIVITYALL
SELF EXAMINATION
What does the Pin Monitoring Relay (PMR) within theGround Power Control Unit ( GPCU ) monitor?
A - The voltage and frequency.B - The correct phase sequence.c - The pin DC voltage at the External Power
Receptacle.
Is the Ground Power Control Unit supplied inflight?
A - Yes from the DC BAT BUS.B - No.C - Yes from the DC GROUND SERVICE BUS.
When the aircraft is on ground, with the externalGround Cart connected, where is the Ground PowerControl Unit supplied from?
A - The Ground Cart and the DC BAT BUS.B - The DC BAT BUS only.c - The Ground Cart only.
TMUELBA01 LEVEL 3
EFFECTIVITY 24-41-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 314EFFECTIVITYALL
24 - ELECTRICAL POWER
24-41-00 EXTERNAL POWER - COMPONENTS
CONTENTS:External Power ContactorGround Power Control UnitExternal Power Receptacle
TMUELBB01 LEVEL 3
EFFECTIVITY 24-41-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 315EFFECTIVITYALL
EXTERNAL POWER - COMPONENTS
EXTERNAL POWER CONTACTOR
IDENTIFICATIONFIN : 3XG
LOCATIONZONE : 212
COMPONENT DESCRIPTIONIt is a plug type contactor.
TMUELBB01-T01 LEVEL 3
EFFECTIVITY 24-41-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 316EFFECTIVITYALL
EXTERNAL POWER - COMPONENTS - EXTERNAL POWER CONTACTOR
TMUELBB01-P01 LEVEL 3
EFFECTIVITY 24-41-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 317EFFECTIVITYALL
EXTERNAL POWER - COMPONENTS
GROUND POWER CONTROL UNIT
IDENTIFICATIONFIN : 1XG
LOCATIONZONE : 122
TMUELBB01-T02 LEVEL 3
EFFECTIVITY 24-41-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 318EFFECTIVITYALL
EXTERNAL POWER - COMPONENTS - GROUND POWER CONTROL UNIT
TMUELBB01-P02 LEVEL 3
EFFECTIVITY 24-41-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 319EFFECTIVITYALL
EXTERNAL POWER - COMPONENTS
EXTERNAL POWER RECEPTACLE - VIEW FROM INSIDE
IDENTIFICATIONFIN : 20XG
LOCATIONZONE : 121
TMUELBB01-T03 LEVEL 3
EFFECTIVITY 24-41-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 320EFFECTIVITYALL
TMUELBB01-P03 LEVEL 3
EXTERNAL POWER - COMPONENTS - EXTERNAL POWER RECEPTACLE - VIEW FROM INSIDE
EFFECTIVITY 24-41-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 321EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBB01 LEVEL 3
EFFECTIVITY 24-41-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 322EFFECTIVITYALL
24 - ELECTRICAL POWER
24-42-00 EXTERNAL POWER - AC/DC GROUNDSERVICE DISTRIBUTION ELECTRICALCIRCUIT
CONTENTS:EXT PWR Pushbutton ONMAINT BUS Switch ONTR2 Failure
TMUELBJ01 LEVEL 3
EFFECTIVITY 24-42-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 323EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION ELECTRICAL CIRCUIT
EXT PWR PUSHBUTTON ON
The whole aircraft electrical network is suppliedincluding the AC and DC GRND FLT Buses.
TMUELBJ01-T01 LEVEL 3
EFFECTIVITY 24-42-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 324EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION ELECTRICAL CIRCUIT - EXT PWRPUSHBUTTON ON
TMUELBJ01-P01 LEVEL 3
EFFECTIVITY 24-42-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 325EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION ELECTRICAL CIRCUIT
MAINT BUS SWITCH ON
External power is available but not in use.Only the AC and DC GRND Buses are supplied.
NOTE: If External Power is in use, an action on theMAINT BUS SWITCH has no effect except for MAINTBUS SWITCH to be on: AC and DC GRND Buses arealready supplied.
TMUELBJ01-T02 LEVEL 3
EFFECTIVITY 24-42-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 326EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION ELECTRICAL CIRCUIT - MAINT BUS SWITCHON
TMUELBJ01-P02 LEVEL 3
EFFECTIVITY 24-42-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 327EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION ELECTRICAL CIRCUIT
TR2 FAILURE
If TR2 fails, the AC and DC GRND FLT Buses are lost.
TMUELBJ01-T03 LEVEL 3
EFFECTIVITY 24-42-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 328EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION ELECTRICAL CIRCUIT - TR2 FAILURETMUELBJ01-P03 LEVEL 3
EFFECTIVITY 24-42-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 329EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBJ01 LEVEL 3
EFFECTIVITY 24-42-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 330EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 EXTERNAL POWER - AC/DC GROUNDSERVICE DISTRIBUTION COMPONENTS
CONTENTS:Contactor 14PUContactors 12XX 14XXContactor 3PXContactor 8PNContactor 12XN
TMUELBO01 LEVEL 3
EFFECTIVITY 24-00-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 331EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION COMPONENTS
CONTACTOR 14PU
IDENTIFICATIONFIN: 14PU
LOCATIONZONE: 212
COMPONENT DESCRIPTIONThis contactor when closed allows AC service BUS andTR2 normal supply.
TMUELBO01-T01 LEVEL 3
EFFECTIVITY 24-00-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 332EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION COMPONENTS - CONTACTOR 14PU
TMUELBO01-P01 LEVEL 3
EFFECTIVITY 24-00-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 333EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION COMPONENTS
CONTACTORS 12XX 14XX
IDENTIFICATIONFIN: 12XX, 14XX
LOCATIONZONE: 212
COMPONENT DESCRIPTIONThey are plug type contactors.
TMUELBO01-T02 LEVEL 3
EFFECTIVITY 24-00-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 334EFFECTIVITYALL
TMUELBO01-P02 LEVEL 3
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION COMPONENTS - CONTACTORS 12XX 14XX
EFFECTIVITY 24-00-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 335EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION COMPONENTS
CONTACTOR 3PX
IDENTIFICATIONFIN: 3PX
LOCATIONZONE: 212
COMPONENT DESCRIPTIONIt is a plug type contactor.
TMUELBO01-T03 LEVEL 3
EFFECTIVITY 24-00-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 336EFFECTIVITYALL
TMUELBO01-P03 LEVEL 3
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION COMPONENTS - CONTACTOR 3PX
EFFECTIVITY 24-00-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 337EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION COMPONENTS
CONTACTOR 8PN
IDENTIFICATIONFIN: 8PN
LOCATIONZONE: 212
COMPONENT DESCRIPTIONThis contactor allows the DC SERVICE Bus normal supply.
TMUELBO01-T04 LEVEL 3
EFFECTIVITY 24-00-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 338EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION COMPONENTS - CONTACTOR 8PN
TMUELBO01-P04 LEVEL 3
EFFECTIVITY 24-00-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 339EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION COMPONENTS
CONTACTOR 12XN
IDENTIFICATIONFIN: 12XN
LOCATIONZONE: 212
TMUELBO01-T05 LEVEL 3
EFFECTIVITY 24-00-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 340EFFECTIVITYALL
EXTERNAL POWER - AC/DC GROUND SERVICE DISTRIBUTION COMPONENTS - CONTACTOR 12XN
TMUELBO01-P05 LEVEL 3
EFFECTIVITY 24-00-00 Page 11May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 341EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBO01 LEVEL 3
EFFECTIVITY 24-00-00 Page 12May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 342EFFECTIVITYALL
24 - ELECTRICAL POWER
24-32-00 DC GENERATION - DC MAINGENERATION D/O
CONTENTS:Transformer RectifiersBatteriesDistributionTransformer Rectifier OperationBattery OperationBattery Charge Limiter FunctionsSelf Examination
TMUELBK01 LEVEL 3
EFFECTIVITY 24-32-00 Page 1Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 343EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION D/O
TRANSFORMER RECTIFIERS
There are three identical Transformer Rectifiers (TR1,TR2, and ESSential TR).Each Transformer Rectifier (TR) converts the threephase AC into 28 VDC.
BATTERIES
There are two identical nickel-cadmium batteries of20 cells each.If the battery voltage is below 25 VDC, when no otherelectrical source is available, a charging cycle isneeded by setting the BAT P/B to ON and supplying theDC normal network to permit charging.The nominal capacity of each battery is 23 Ah.
DISTRIBUTION
TR1, powered from AC BUS 1, supplies DC BUS 1 and DCBAT BUS.TR2, powered from AC BUS 2, supplies DC BUS 2.The ESS TR is either supplied from the AC ESS BUS orthe EMERGENCY GENERATOR. It can supply the DC ESS BUSand the DC ESSENTIAL SHEDDABLE BUS when required.The two batteries are connected to the DC BAT BUS.Battery 1 can also supply the static inverter andBattery 2 can supply the DC ESS BUS.
TRANSFORMER RECTIFIER OPERATION
The Transformer Rectifiers start to operate as soonas they are supplied by the associated AC busbar.Automatic switching is provided in case of TR1 or TR2failure, to guarantee power supply to all affected DCbusbars.
BATTERY OPERATION
Battery 1 and Battery 2 are charged from DC BAT BUSthrough contactors.These contactors are controlled by the Battery ChargeLimiters (BCL).
BATTERY CHARGE LIMITER FUNCTIONS
Each BCL controls its battery contactor. The BCLs areidentical and interchangeable.The battery contactors are controlled in order to:
- ensure automatic battery connection forcharging,
- protect the battery against thermal runawayand short circuit,
- prevent complete discharging.
TMUELBK01-T01 LEVEL 3
EFFECTIVITY 24-32-00 Page 2Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 344EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION D/OTMUELBK01-P01 LEVEL 3
EFFECTIVITY 24-32-00 Page 3Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 345EFFECTIVITYALL
SELF EXAMINATION
Which power source supplies the ESS TR?A - AC BUS 1 or AC BUS 2.B - AC BUS 1 AND AC BUS 2.C - AC ESS BUS or EMERGENCY GENERATOR.
Which equipment controls the battery contactor?A - GCUB - BCLC - Static Inverter.
TMUELBK01 LEVEL 3
EFFECTIVITY 24-32-00 Page 4Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 346EFFECTIVITYALL
24 - ELECTRICAL POWER
24-35-00 DC GENERATION - DC NORMAL ANDESSENTIAL GENERATION SWITCHINGD/O
CONTENTS:Normal ConfigurationTR1 LossTR2 LossSelf Examination
TMUELBM01 LEVEL 3
EFFECTIVITY 24-35-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 347EFFECTIVITYALL
DC GENERATION - DC NORMAL AND ESSENTIAL GENERATION SWITCHING D/O
NORMAL CONFIGURATION
In normal configuration TR 1 supplies successively DCBUS 1, DC BAT BUS, DC ESSENTIAL BUS and DC ESSENTIALSHED BUS.TR 2 supplies only DC BUS 2.
TMUELBM01-T01 LEVEL 3
EFFECTIVITY 24-35-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 348EFFECTIVITYALL
DC GENERATION - DC NORMAL AND ESSENTIAL GENERATION SWITCHING D/O - NORMAL CONFIGURATION
TMUELBM01-P01 LEVEL 3
EFFECTIVITY 24-35-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 349EFFECTIVITYALL
DC GENERATION - DC NORMAL AND ESSENTIAL GENERATION SWITCHING D/O
TR1 LOSS
If TR1 fails, TR2 automatically supplies DC BAT BUSand DC BUS 1 through DC BUS 2.The DC ESSENTIAL BUS supply is automaticallytransferred from DC BAT BUS to AC ESSENTIAL BUS throughthe ESSENTIAL Transformer Rectifier.
TMUELBM01-T02 LEVEL 3
EFFECTIVITY 24-35-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 350EFFECTIVITYALL
DC GENERATION - DC NORMAL AND ESSENTIAL GENERATION SWITCHING D/O - TR1 LOSS
TMUELBM01-P02 LEVEL 3
EFFECTIVITY 24-35-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 351EFFECTIVITYALL
DC GENERATION - DC NORMAL AND ESSENTIAL GENERATION SWITCHING D/O
TR2 LOSS
If TR 2 fails, TR 1 automatically supplies DC BUS 2through DC BUS 1 and DC BAT BUS.The DC ESSENTIAL BUS supply is automaticallytransferred from DC BAT BUS to AC ESSENTIAL BUS throughthe ESSENTIAL Transformer Rectifier.
TMUELBM01-T03 LEVEL 3
EFFECTIVITY 24-35-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 352EFFECTIVITYALL
DC GENERATION - DC NORMAL AND ESSENTIAL GENERATION SWITCHING D/O - TR2 LOSS
TMUELBM01-P03 LEVEL 3
EFFECTIVITY 24-35-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 353EFFECTIVITYALL
SELF EXAMINATION
What is the DC ESS network power source if TR 1 hasfailed?
A - AC ESS BUSB - DC BAT BUSC - CSM/G
What is the DC ESS Bus supply if TR 2 has failed?A - TR 1B - ESS TRC - BAT 2
TMUELBM01 LEVEL 3
EFFECTIVITY 24-35-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 354EFFECTIVITYALL
24 - ELECTRICAL POWER
24-35-00 DC GENERATION - DC NORMAL ANDESS GENERATION SWITCHINGELECTRICAL CIRCUIT
CONTENTS:Normal ConfigurationTR1 or TR2 LossDC Bus Tie Failure
TMUELBN01 LEVEL 3
EFFECTIVITY 24-35-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 355EFFECTIVITYALL
DC GENERATION - DC NORMAL AND ESS GENERATION SWITCHING ELECTRICAL CIRCUIT
NORMAL CONFIGURATION
TMUELBN01-T01 LEVEL 3
EFFECTIVITY 24-35-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 356EFFECTIVITYALL
DC GENERATION - DC NORMAL AND ESS GENERATION SWITCHING ELECTRICAL CIRCUIT - NORMALCONFIGURATION
TMUELBN01-P01 LEVEL 3
EFFECTIVITY 24-35-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 357EFFECTIVITYALL
DC GENERATION - DC NORMAL AND ESS GENERATION SWITCHING ELECTRICAL CIRCUIT
TR1 OR TR2 LOSS
This configuration shows a TR1 loss.
TMUELBN01-T02 LEVEL 3
EFFECTIVITY 24-35-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 358EFFECTIVITYALL
DC GENERATION - DC NORMAL AND ESS GENERATION SWITCHING ELECTRICAL CIRCUIT - TR1 OR TR2LOSS
TMUELBN01-P02 LEVEL 3
EFFECTIVITY 24-35-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 359EFFECTIVITYALL
DC GENERATION - NORMAL AND ESS GENERATION SWITCHING ELECTRICAL CIRCUIT
DC BUS TIE FAILURE
In the event of a DC bus tie contactor failure (4PCor 1PC1) the DC ESS bus supply is recovered from theESS TR. The DC BUS TIE class 2 failure message isdisplayed on the ECAM status page.
TMUELBN01-T03 LEVEL 3
EFFECTIVITY 24-35-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 360EFFECTIVITYALL
DC GENERATION - DC NORMAL AND ESS GENERATION SWITCHING ELECTRICAL CIRCUIT - DC BUS TIEFAILURE
TMUELBN01-P03 LEVEL 3
EFFECTIVITY 24-35-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 361EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBN01 LEVEL 3
EFFECTIVITY 24-35-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 362EFFECTIVITYALL
24 - ELECTRICAL POWER
24-32-00 DC GENERATION - TRANSFORMERRECTIFIER D/O
CONTENTS:GeneralTR ProtectionTR1 Normal ConfigurationTR1 Abnormal ConfigurationTR1 Reset ConfigurationTR2Essential TRSelf Examination
TMUELBL01 LEVEL 3
EFFECTIVITY 24-32-00 Page 1Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 363EFFECTIVITYALL
DC GENERATION - TRANSFORMER RECTIFIER D/O
GENERAL
Three identical Tranformer Rectifiers (TR) are fittedon the aircraft. They operate as soon as they aresupplied. The Transformer Rectifiers (TR) are suppliedwith three phase 115 V/400 Hz.Each TR controls its contactor via an internal logic.
TR PROTECTION
Each Transformer Rectifier control logic consists ofan overheat protection and a minimum current flowdetection to isolate the distribution circuit from theTransformer Rectifier.
TR1 NORMAL CONFIGURATION
As soon as AC Bus1 is supplied, the TransformerRectifier output is delivered to the DC Bus through acontrol contactor which is energized by the TRprotection module.The protection module is supplied by DC Bus 2 (204PP).The Transformer Rectifier current, voltage as well asthe TR contactor position indications are sent to theECAM system via SDAC 1 and 2.
TMUELBL01-T01 LEVEL 3
EFFECTIVITY 24-32-00 Page 2Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 364EFFECTIVITYALL
DC GENERATION - TRANSFORMER RECTIFIER D/OTMUELBL01-P01 LEVEL 3
EFFECTIVITY 24-32-00 Page 3Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 365EFFECTIVITYALL
DC GENERATION - TRANSFORMER RECTIFIER D/O
TR1 ABNORMAL CONFIGURATION
In the event of a TR fault detection, the DC bus 1control contactor is no longer energized.The fault signals are sent to the ECAM system, theCFDIU and to the DC normal generation switching system(1PC1-1PC2)
TMUELBL01-T02 LEVEL 3
EFFECTIVITY 24-32-00 Page 4Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 366EFFECTIVITYALL
DC GENERATION - TRANSFORMER RECTIFIER D/O - TR1 ABNORMAL CONFIGURATIONTMUELBL01-P02 LEVEL 3
EFFECTIVITY 24-32-00 Page 5Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 367EFFECTIVITYALL
DC GENERATION - TRANSFORMER RECTIFIER D/O
TR1 RESET CONFIGURATION
When the fault disappears, the TR remains deactivated.Reset action is necessary for TR reactivation.The Transformer Rectifier protection reset is possibleeither from the Centralized Fault Display System viaMCDU or from the pusbutton located in the avionicsbay.
TMUELBL01-T03 LEVEL 3
EFFECTIVITY 24-32-00 Page 6Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 368EFFECTIVITYALL
DC GENERATION - TRANSFORMER RECTIFIER D/O - TR1 RESET CONFIGURATIONTMUELBL01-P03 LEVEL 3
EFFECTIVITY 24-32-00 Page 7Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 369EFFECTIVITYALL
DC GENERATION - TRANSFORMER RECTIFIER D/O
TR2
The operation of TR2 is identical to that of TR1.When AC and DC GRND FLT Buses are only supplied byexternal power, the TR2 minimum current detectionsystem is inhibited.
TMUELBL01-T04 LEVEL 3
EFFECTIVITY 24-32-00 Page 8Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 370EFFECTIVITYALL
DC GENERATION - TRANSFORMER RECTIFIER D/O - TR2TMUELBL01-P04 LEVEL 3
EFFECTIVITY 24-32-00 Page 9Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 371EFFECTIVITYALL
DC GENERATION - TRANSFORMER RECTIFIER D/O
ESSENTIAL TR
The essential TR operation is identical to that of TR1and TR2.ESS TR fault signals are sent to Flight WarningComputer 1 and 2.
TMUELBL01-T05 LEVEL 3
EFFECTIVITY 24-32-00 Page 10Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 372EFFECTIVITYALL
DC GENERATION - TRANSFORMER RECTIFIER D/O - ESSENTIAL TRTMUELBL01-P05 LEVEL 3
EFFECTIVITY 24-32-00 Page 11Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 373EFFECTIVITYALL
SELF EXAMINATION
What are the protections for a TransformerRectifier unit?
A - Overheat and minimum current detection.B - Overheat and overvoltage detection.C - Overheat and overcurrent detection.
How can a Tranformer Rectifier unit be reset?A - Either from the Battery Charge Limiter
or a pushbutton in the avionics bay.B - Either from a pusbutton in the avionics
bay or automatically at power up.C - Either from the Centralized Fault
Display System or a pushbutton in theavionics bay.
When is the TR2 minimum current detection systeminhibited?
A - On ground when the aircraft electricalnetwork is supplied by the APU generator.
B - On ground when the AC and DC GRND FLTBuses are only supplied by externalpower.
C - On ground when the AC and DC GRND FLTBuses are supplied by external power.
TMUELBL01 LEVEL 3
EFFECTIVITY 24-32-00 Page 12Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 374EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 DC GENERATION - DC MAINGENERATION COMPONENTS
CONTENTS:Main TRsContactor 3PEContactors 5PU1-5PU2Contactors 1PC1-1PC2Contactor 4PCESS TR
TMUELBP01 LEVEL 3
EFFECTIVITY 24-00-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 375EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS
MAIN TRs
IDENTIFICATIONFIN: 1PU 1/2
LOCATIONZONE: 126
COMPONENT DESCRIPTIONMain TRs are ventilated by the aircraft ventilationnetwork. Power delivered: 28VDC-200AWeight: 5 kgDC voltage:
- 30.2V with no load- 27.5V at 200A
TMUELBP01-T01 LEVEL 3
EFFECTIVITY 24-00-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 376EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS - MAIN TRs
TMUELBP01-P01 LEVEL 3
EFFECTIVITY 24-00-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 377EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS
CONTACTOR 3PE
IDENTIFICATIONFIN: 3PE
LOCATIONZONE: 125
COMPONENT DESCRIPTIONThis contactor, controlled by its transformerrectifier via an internal TR logic makes DC poweravailable for DC ESS BUS.
TMUELBP01-T02 LEVEL 3
EFFECTIVITY 24-00-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 378EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS - CONTACTOR 3PE
TMUELBP01-P02 LEVEL 3
EFFECTIVITY 24-00-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 379EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS
CONTACTORS 5PU1-5PU2
IDENTIFICATIONFIN: 5PU 1/2
LOCATIONZONE: 212
COMPONENT DESCRIPTIONThese contactors, controlled by their TransformerRectifiers via an internal TR logic make DC poweravailable for its DC BUS.
TMUELBP01-T03 LEVEL 3
EFFECTIVITY 24-00-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 380EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS - CONTACTORS 5PU1-5PU2
TMUELBP01-P03 LEVEL 3
EFFECTIVITY 24-00-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 381EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS
CONTACTORS 1PC1-1PC2
IDENTIFICATIONFIN: 1PC 1/2
LOCATIONZONE: 212
COMPONENT DESCRIPTIONThese contactors allow respectively DC BUS1 and DCBUS2 switching.
TMUELBP01-T04 LEVEL 3
EFFECTIVITY 24-00-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 382EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS - CONTACTORS 1PC1-1PC2
TMUELBP01-P04 LEVEL 3
EFFECTIVITY 24-00-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 383EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS
CONTACTOR 4PC
IDENTIFICATIONFIN: 4PC
LOCATIONZONE: 125
COMPONENT DESCRIPTIONThis contactor supplies, in some cases, the DC ESS busbar.
TMUELBP01-T05 LEVEL 3
EFFECTIVITY 24-00-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 384EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS - CONTACTOR 4PC
TMUELBP01-P05 LEVEL 3
EFFECTIVITY 24-00-00 Page 11May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 385EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS
ESS TR
IDENTIFICATIONFIN: 1PE
LOCATIONZONE: 125
COMPONENT DESCRIPTIONPower delivered: 28VDC-200AWeight: 5 kgDC voltage:
- 30.2 v with no load- 27.5 v at 200A
TMUELBP01-T06 LEVEL 3
EFFECTIVITY 24-00-00 Page 12May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 386EFFECTIVITYALL
DC GENERATION - DC MAIN GENERATION COMPONENTS - ESS TR
TMUELBP01-P06 LEVEL 3
EFFECTIVITY 24-00-00 Page 13May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 387EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBP01 LEVEL 3
EFFECTIVITY 24-00-00 Page 14May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 388EFFECTIVITYALL
24 - ELECTRICAL POWER
24-38-00 DC GENERATION - BATTERY SYSTEMD/O
CONTENTS:GeneralBattery DescriptionBattery ControlIndicating/MonitoringSelf Examination
TMUELBQ02 LEVEL 3
EFFECTIVITY 24-38-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 389EFFECTIVITYALL
DC GENERATION - BATTERY SYSTEM D/O
GENERAL
The battery system is composed of two batteries whichare mainly used to start the APU and supply AC and DCessential network in emergency configuration.
Each battery is associated to one Battery ChargeLimiter (BCL). The BCL ensures battery charge andbattery protection by controlling the batterycontactor.
BATTERY DESCRIPTION
The two batteries are identical and interchangeable.Each battery is ventilated by two ducts. Thedifferential pressure between the cabin and the outsideis used to provide battery ventilation.
Each battery has 20 nickel cadmium cells in a stainlesssteel case. Each cell can be removed separately.
Battery nominal voltage: 24 VDC.Battery nominal capacity: 23 Ah.
BATTERY CONTROL
Each battery is associated to a Battery Charge Limiterwhich is controlled by the corresponding batterypushbutton.
When the BAT pushbutton is pressed in (AUTO position),the BCL controls the battery coupling / uncoupling.When released out, the battery is uncoupled from thenetwork and the white OFF light comes on.
NOTE: In flight, in normal configuration, thebatteries are uncoupled from the network.
INDICATING/MONITORING
Battery parameters such as voltage, current andwarnings are displayed by the ECAM.The voltmeters, located on the main control panel,give battery voltage indication even in a cold aircraftconfiguration.
The BCLs monitor the charge of the batteries.In the event of battery thermal runaway or internalshort circuit, the battery is isolated, the amber FAULTlight comes on and the ECAM system is activated.System failures and BITE data are sent to theCentralized Fault Display System (CFDS).
TMUELBQ02-T01 LEVEL 3
EFFECTIVITY 24-38-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 390EFFECTIVITYALL
DC GENERATION - BATTERY SYSTEM D/OTMUELBQ02-P01 LEVEL 3
EFFECTIVITY 24-38-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 391EFFECTIVITYALL
SELF EXAMINATION
In cold aircraft configuration (no AC and DCsupply), where is (are) the battery indication(s)displayed?
A - On the ECAM.B - On the ELEC PWR control panel.C - There is no indication.
When does the BAT FAULT light come on?A - When the BAT pushbutton is set to OFF.B - When the discharge current is too high.C - When a thermal runaway or an internal
short circuit occurs.
TMUELBQ02 LEVEL 3
EFFECTIVITY 24-38-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 392EFFECTIVITYALL
24 - ELECTRICAL POWER
24-38-00 DC GENERATION - BATTERY CHARGELIMITER D/O
CONTENTS:GeneralPurposeBattery Charge(Pushbutton In)Protection 1: Thermal Runaway or Short Circuit
ProtectionProtection 2: Complete Discharge ProtectionProtection 3: Hot Bus ProtectionEmergency ConfigurationAPU StartEMER GEN FAULT ControlBAT FAULT ControlSelf Examination
TMUELBR02 LEVEL 3
EFFECTIVITY 24-38-00 Page 1Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 393EFFECTIVITYALL
DC GENERATION - BATTERY CHARGE LIMITER D/O
GENERAL
The two Battery Charge Limiters (BCL) are identicaland interchangeable. Pin programming determines theposition of the BCL and the aircraft type.
PURPOSE
The main function of the BCL is to control the batterycontactor and battery FAULT warning. Also, BCL 1 andBCL 2 control the emergency generator FAULT warning.The battery contactor control includes the followingfunctions: protection of the battery against thermalrunaway or short circuit, ensuring battery charge,preventing complete discharge, ensuring integrity ofthe HOT BUS, assisting starting of the APU.NOTE: BCL 1 and 2 also ensure battery power supply to
part of the network during transientconfiguration or on ground when no normal poweris available.
BATTERY CHARGE(PUSHBUTTON IN)
When battery voltage is lower than 26.5 Volts and BATBUS voltage is higher than 27 Volts (checked by theacquisition module), the battery is connected viacontactor 6PB1.When the charge current sensed by the battery shuntis less than 4 Amps decreasing for 10 seconds on groundor 30 minutes in flight or following APU start,thebattery is fully charged, the contactor opens and thebattery charge stops.
THERMAL RUNAWAY OR SHORT CIRCUIT PROTECTION
If the charge current is above 10 Amps and increasingby more than 0.375 Amps per minute or the charge currentis greater than 150 Amps for 90 seconds, the contactoropens. The Short Circuit Hardware Protection detectsthe malfunction of the battery and stops the supplyof the BCL.
COMPLETE DISCHARGE PROTECTION
On ground, when the battery voltage is lower than 23Volts for 15 seconds, the contactor opensautomatically.
HOT BUS PROTECTION
In order to maintain the HOT BUS supply, the contactoropens under these conditions:
- discharge current greater than 100 Amps for300 ms
- discharge current greater than 400 Amps for 5ms
EMERGENCY CONFIGURATION
The batteries are connected to the BATTERY BUS afterlanding in emergency configuration.The battery contactors are closed by the BCL when theaircraft speed is lower than 100 Kts.
TMUELBR02-T01 LEVEL 3
EFFECTIVITY 24-38-00 Page 2Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 394EFFECTIVITYALL
DC GENERATION - BATTERY CHARGE LIMITER D/OTMUELBR02-P01 LEVEL 3
EFFECTIVITY 24-38-00 Page 3Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 395EFFECTIVITYALL
DC GENERATION - BATTERY CHARGE LIMITER D/O
APU START
The APU can be started by the batteries alone or bythe normal supply.When the APU start sequence is initiated (APU masterswitch to ON), batteries are connected in order towithstand the high APU starter motor demand.When the APU start sequence is completed (50%N1), relay6KD closes to interrupt the APU START signal.In flight, in electrical emergency configuration, theAPU start sequence is locked out until the CSM/G isconnected to the network or after 45 seconds.
EMER GEN FAULT CONTROL
In emergency configuration, if the CSM/G is inoperativeor during transient configuration, the FAULT legendon the emergency generator pushbutton comes on(controlled by BCL 1 and 2).
BAT FAULT CONTROL
In case of thermal runaway or short circuit, the FAULTlegend of the BAT pushbutton comes on.An amber message and the ELEC page are displayed onthe ECAM, the MASTER CAUTION lights come on and thesingle chime sounds.NOTE: The 5 Volts for the OFF light are delivered via
15PB and 17PB resistors.
TMUELBR02-T02 LEVEL 3
EFFECTIVITY 24-38-00 Page 4Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 396EFFECTIVITYALL
DC GENERATION - BATTERY CHARGE LIMITER D/OTMUELBR02-P02 LEVEL 3
EFFECTIVITY 24-38-00 Page 5Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 397EFFECTIVITYALL
SELF EXAMINATION
When does the protection for complete dischargeopen the battery contactor?
A - In flight when the battery voltage islower than 23 Volts for 15 seconds.
B - On ground when the battery voltage islower than 23 Volts for 15 seconds.
C - When the battery voltage is lower than23 Volts for 15 seconds at any time.
In flight, in electrical emergency configuration,the APU start sequence is locked out:
A - Until the CSM/G is coupled to thenetwork or during 45 seconds.
B - When the CSM/G is coupled to the network.C - 45 seconds after the CSM/G is coupled to
the network.
TMUELBR02 LEVEL 3
EFFECTIVITY 24-38-00 Page 6Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 398EFFECTIVITYALL
24 - ELECTRICAL POWER
24-38-00 DC GENERATION - BATTERYCOMPONENTS
CONTENTS:VoltmetersBatteriesContactorsBattery Charge Limiters
TMUELBT02 LEVEL 3
EFFECTIVITY 24-38-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 399EFFECTIVITYALL
DC GENERATION - BATTERY COMPONENTS
VOLTMETERS
IDENTIFICATIONFIN: 3PV1, 3PV2
LOCATIONZONE: 211
COMPONENT DESCRIPTIONThe voltmeters, located on the overhead panel, indicateto the flight crew the voltage of hot busses.The digital display is a Liquid Crystal Display unitwhich includes a lighting system.
TMUELBT02-T01 LEVEL 3
EFFECTIVITY 24-38-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 400EFFECTIVITYALL
DC GENERATION - BATTERY COMPONENTS - VOLTMETERS
TMUELBT02-P01 LEVEL 3
EFFECTIVITY 24-38-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 401EFFECTIVITYALL
DC GENERATION - BATTERY COMPONENTS
BATTERIES
IDENTIFICATIONFIN: 2PB1, 2PB2
LOCATIONZONE: 126
COMPONENT DESCRIPTIONEach battery of the nickel-cadmium type is composedof twenty elements housed in a stainless steel case.
- Nominal voltage: 24 VDC.- Nominal capacity: 23 Ah.
TMUELBT02-T02 LEVEL 3
EFFECTIVITY 24-38-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 402EFFECTIVITYALL
DC GENERATION - BATTERY COMPONENTS - BATTERIES
TMUELBT02-P02 LEVEL 3
EFFECTIVITY 24-38-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 403EFFECTIVITYALL
DC GENERATION - BATTERY COMPONENTS
CONTACTORS
IDENTIFICATIONFIN: 6PB1, 6PB2
LOCATIONZONE: 126
COMPONENT DESCRIPTIONThe battery contactors are controlled by Battery ChargeLimiters.
TMUELBT02-T03 LEVEL 3
EFFECTIVITY 24-38-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 404EFFECTIVITYALL
DC GENERATION - BATTERY COMPONENTS - CONTACTORS
TMUELBT02-P03 LEVEL 3
EFFECTIVITY 24-38-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 405EFFECTIVITYALL
DC GENERATION - BATTERY COMPONENTS
BATTERY CHARGE LIMITERS
IDENTIFICATIONFIN: 1PB1, 1PB2
LOCATIONZONE: 126
COMPONENT DESCRIPTIONThe main function of the Battery Charge Limiters isto control the battery contactors.They also have three auxiliary functions:
- RAT and EMER GEN FAULT control,- Inhibition of APU start sequence,- Static inverter monitoring.
TMUELBT02-T04 LEVEL 3
EFFECTIVITY 24-38-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 406EFFECTIVITYALL
DC GENERATION - BATTERY COMPONENTS - BATTERY CHARGE LIMITERS
TMUELBT02-P04 LEVEL 3
EFFECTIVITY 24-38-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 407EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBT02 LEVEL 3
EFFECTIVITY 24-38-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 408EFFECTIVITYALL
24 - ELECTRICAL POWER
24-56-00 AC AND DC LOAD DISTRIBUTION -GALLEY SUPPLY D/O
CONTENTS:Electrical SupplyControlsLoad MonitoringAuto SheddingSelf Examination
TMUELBG02 LEVEL 3
EFFECTIVITY 24-56-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 409EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O
ELECTRICAL SUPPLY
The power supply provides the galleys with 115 VoltsAC.There are 50 KVA available for all the galleys. Thispower is divided into two parts: the AFT galley powerwith 30 KVA and the FWD galley power with 20 KVA.
TMUELBG02-T01 LEVEL 3
EFFECTIVITY 24-56-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 410EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O - ELECTRICAL SUPPLYTMUELBG02-P01 LEVEL 3
EFFECTIVITY 24-56-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 411EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O
CONTROLS
EXT PWR OR APU GEN SUPPLYWith the GALLEY pushbutton in the AUTO position andthe electrical network supplied by either the GroundCart or the APU, all the galleys are supplied.The galleys are cut off by releasing out the GALLEYpushbutton (OFF light on) .
TMUELBG02-T02 LEVEL 3
EFFECTIVITY 24-56-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 412EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O - CONTROLS - EXTERNAL POWER OR APU GENSUPPLY
TMUELBG02-P02 LEVEL 3
EFFECTIVITY 24-56-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 413EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O
CONTROLS
IDG1 AND IDG2 SUPPLYWith the aircraft electrical network supplied by bothIntegrated Drive Generators, the galleys are supplied.In flight, two generators are required to supply thewhole galley network :
- -two IDGs or -IDG1(2) and APU GEN .
NOTE : on ground, with no APU and no external power,two IDGs are also required to supply the whole galleynetwork.
TMUELBG02-T03 LEVEL 3
EFFECTIVITY 24-56-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 414EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O - CONTROLS - IDG1 AND IDG2 SUPPLYTMUELBG02-P03 LEVEL 3
EFFECTIVITY 24-56-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 415EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O
LOAD MONITORING
If the Generator Control Unit detects a generatoroverload, the GALLEY FAULT light comes on. In thiscase the galleys have to be manually cut off.The ECAM system is activated through the EGIUs.
TMUELBG02-T04 LEVEL 3
EFFECTIVITY 24-56-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 416EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O - LOAD MONITORINGTMUELBG02-P04 LEVEL 3
EFFECTIVITY 24-56-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 417EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O
AUTO SHEDDING
APU SUPPLY ON GROUNDOn ground, in case of APU generator overload, the wholegalley network is automatically shed.At the same time, the Galley FAULT light comes on andthe ECAM system is triggered.
TMUELBG02-T05 LEVEL 3
EFFECTIVITY 24-56-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 418EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O - AUTO SHEDDING - APU SUPPLY ON GROUNDTMUELBG02-P05 LEVEL 3
EFFECTIVITY 24-56-00 Page 11May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 419EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O
AUTO SHEDDING
ONE GEN SUPPLY IN FLIGHTIn flight, in single generator operationconfiguration, the power fed to the galleys is limitedto 10 KVA : 5 KVA for FWD galleys and 5 KVA for AFTgalleys.The GALLEY SHED indication is displayed on the ELECECAM page.
TMUELBG02-T06 LEVEL 3
EFFECTIVITY 24-56-00 Page 12May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 420EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY D/O - AUTO SHEDDING - ONE GEN SUPPLY IN FLIGHTTMUELBG02-P06 LEVEL 3
EFFECTIVITY 24-56-00 Page 13May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 421EFFECTIVITYALL
SELF EXAMINATION
In which of the following configurations is the wholegalley network shed when an overload occurs ?
- A - In flight with two IDG supply.- B - On ground with APU supply only.- C - On ground with EXT PWR only.
What does the GALLEY FAULT light indicate ?- A - The AFT galley has been shed.- B - The galleys have been shed.- C - An overload on any generator (APU or IDG).
TMUELBG02 LEVEL 3
EFFECTIVITY 24-56-00 Page 14May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 422EFFECTIVITYALL
24 - ELECTRICAL POWER
24-56-00 AC AND DC LOAD DISTRIBUTION -GALLEY SUPPLY COMPONENTS
CONTENTS:Galley Supply Contactors
TMUELBH02 LEVEL 3
EFFECTIVITY 24-56-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 423EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY COMPONENTS
GALLEY SUPPLY CONTACTORS
IDENTIFICATIONFIN: 4MC, 5MC, 6MC, 13MC, 15MC, 17MC
LOCATIONZONE: 220
TMUELBH02-T01 LEVEL 3
EFFECTIVITY 24-56-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 424EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - GALLEY SUPPLY COMPONENTS - GALLEY SUPPLY CONTACTORS
TMUELBH02-P01 LEVEL 3
EFFECTIVITY 24-56-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 425EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBH02 LEVEL 3
EFFECTIVITY 24-56-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 426EFFECTIVITYALL
24 - ELECTRICAL POWER
24-67-00 AC AND DC LOAD DISTRIBUTION -REFUELING ON BATTERY
CONTENTS:GeneralGround Service ConfigurationBattery Only ConfigurationSelf Examination
TMUELCB02 LEVEL 3
EFFECTIVITY 24-67-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 427EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - REFUELING ON BATTERY
GENERAL
The refueling electrical network consists of busbars501PP and 502PP. It is supplied as soon as the refueldoor located on the fuselage below the right wing isopened.Two supplies are then possible:
- 28VDC service bus 601PP (supplied from normalnetwork or via MAINT BUS switch).
- Hot bus 701PP if no other power isavailable.
TMUELCB02-T01 LEVEL 3
EFFECTIVITY 24-67-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 428EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - REFUELING ON BATTERY - GENERALTMUELCB02-P01 LEVEL 3
EFFECTIVITY 24-67-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 429EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - REFUELING ON BATTERY
GROUND SERVICE CONFIGURATION
NOTE: MAINT BUS switch is set to ON.As soon as refuel door is opened, relay 8PR is energizedby service bus 601PP via relay 5PR.Refueling busbars 501PP and 502PP are then suppliedby service bus 601PP via relay 8PR.NOTE: in normal supply configuration, contactor 3PX
is opened and contactor 8PN is closed.
TMUELCB02-T02 LEVEL 3
EFFECTIVITY 24-67-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 430EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - REFUELING ON BATTERY - GROUND SERVICE CONFIGURATIONTMUELCB02-P02 LEVEL 3
EFFECTIVITY 24-67-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 431EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - REFUELING ON BATTERY
BATTERY ONLY CONFIGURATION
When spring loaded switch 10PR is set to ON and refueldoor open, relay 5PR is energized by HOT BUS 701PP.Relay 8PR is energized, allowing refueling busbars tobe supplied by HOT BUS 701PP.Relay 11PR is energized by 501PP via mode selector 3QUso that relay 5PR remains energized.Time delay closing relay 12PR is energized by 701PP.When it closes after 10mn, refueling power isautomatically cut off even if refuel door is stillopen.
TMUELCB02-T03 LEVEL 3
EFFECTIVITY 24-67-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 432EFFECTIVITYALL
AC AND DC LOAD DISTRIBUTION - REFUELING ON BATTERY - BATTERY ONLY CONFIGURATIONTMUELCB02-P03 LEVEL 3
EFFECTIVITY 24-67-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 433EFFECTIVITYALL
SELF EXAMINATION
In which configuration is refueling power supplyautomatically cut off ten minutes after?
A - Refueling busbars supplied by servicebus 601PP.
B - Refueling busbars supplied by hot bus701PP.
C - Both configurations.
TMUELCB02 LEVEL 3
EFFECTIVITY 24-67-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 434EFFECTIVITYALL
24 - ELECTRICAL POWER
24-22-00 ECAM ELECTRICAL POWER INTERFACES- ELECTRICAL GENERATIONINTERFACE UNIT (EGIU)
CONTENTS:PresentationIDG1 or IDG2APU GENExternal Power
TMUELBU01 LEVEL 3
EFFECTIVITY 24-22-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 435EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU)
PRESENTATION
The function of the Electrical Generation InterfaceUnit is to convert analog and discrete signals fromthe Generator Control Unit and Ground Power ControlUnit into ARINC 429 data.Two identical EGIUs are used.Each one consists of two isolated channels:
- channel 1 is allocated to IDG1 or IDG2.- channel 2 is allocated to APU Generator orExternal Power.
TMUELBU01-T01 LEVEL 3
EFFECTIVITY 24-22-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 436EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU) -PRESENTATIONT
MUELBU01-P01 LEVEL 3
EFFECTIVITY 24-22-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 437EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU)
IDG1 OR IDG2
The information provided to the SDAC is shown on thescreen.The parameters are displayed on the ECAM system.
TMUELBU01-T02 LEVEL 3
EFFECTIVITY 24-22-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 438EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU) - IDG1 ORIDG2T
MUELBU01-P02 LEVEL 3
EFFECTIVITY 24-22-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 439EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU)
APU GEN
The information provided to the SDAC is shown on thescreen.The parameters are displayed on the ECAM system.
TMUELBU01-T03 LEVEL 3
EFFECTIVITY 24-22-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 440EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU) - APU GEN
TMUELBU01-P03 LEVEL 3
EFFECTIVITY 24-22-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 441EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU)
EXTERNAL POWER
The information provided to the SDAC is shown on thescreen.The parameters are displayed on the ECAM system.
NOTE: the Flip Flop circuit in the EGIU memorizes thecontrol signal from the EXT PWR pushbutton switch(the pushbutton switch not being mechanicallylatch-in: a first press switches the externalpower "ON", a second press switches it "AVAIL").The Flip Flop circuit allows the latching of theExternal Power Contactor auxiliary relay. Theinformation "External Power ON" is thus providedto the SDACs.
TMUELBU01-T04 LEVEL 3
EFFECTIVITY 24-22-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 442EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU) - EXTERNALPOWERT
MUELBU01-P04 LEVEL 3
EFFECTIVITY 24-22-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 443EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBU01 LEVEL 3
EFFECTIVITY 24-22-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 444EFFECTIVITYALL
24 - ELECTRICAL POWER
24-22-00 ECAM ELECTRICAL POWER INTERFACE- COMPONENTS
CONTENTS:Electrical Generation Interface Unit (EGIU)
TMUELCE01 LEVEL 3
EFFECTIVITY 24-22-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 445EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACE - COMPONENTS
EGIU
IDENTIFICATIONFIN: 22XU
LOCATIONZONE: 121
COMPONENT DESCRIPTIONThe EGIU transmits the main parameters from theGenerators Control Units to the System Data AcquisitionConcentrators via ARINC 429 data links.
TMUELCE01-T01 LEVEL 3
EFFECTIVITY 24-22-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 446EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACE - COMPONENTS - EGIU
TMUELCE01-P01 LEVEL 3
EFFECTIVITY 24-22-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 447EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELCE01 LEVEL 3
EFFECTIVITY 24-22-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 448EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 ECAM ELECTRICAL POWER INTERFACES- AC/DC BUS OFF WARNING LOGICS
CONTENTS:AC MainAC ESSDC MainDC ESS
TMUELBY01 LEVEL 3
EFFECTIVITY 24-00-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 449EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - AC/DC BUS OFF WARNING LOGICS
AC MAIN
The ECAM is activated as soon as the correspondingsub-busbar is no longer supplied.
TMUELBY01-T01 LEVEL 3
EFFECTIVITY 24-00-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 450EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - AC/DC BUS OFF WARNING LOGICS - AC MAINTMUELBY01-P01 LEVEL 3
EFFECTIVITY 24-00-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 451EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - AC/DC BUS OFF WARNING LOGICS
AC ESS
The ECAM is activated as soon as the correspondingbusbar or sub-busbar is no longer supplied.
TMUELBY01-T02 LEVEL 3
EFFECTIVITY 24-00-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 452EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - AC/DC BUS OFF WARNING LOGICS - AC ESSTMUELBY01-P02 LEVEL 3
EFFECTIVITY 24-00-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 453EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - AC/DC BUS OFF WARNING LOGICS
DC MAIN
The ECAM warning is activated as soon as thecorresponding sub-busbar is no longer supplied.
TMUELBY01-T03 LEVEL 3
EFFECTIVITY 24-00-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 454EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - AC/DC BUS OFF WARNING LOGICS - DC MAINTMUELBY01-P03 LEVEL 3
EFFECTIVITY 24-00-00 Page 7May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 455EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - AC/DC BUS OFF WARNING LOGICS
DC ESS
The ECAM system is activated when:- The sub-busbar is lost.- The DC ESS BUS SHED contactor (8PH) is open.
TMUELBY01-T04 LEVEL 3
EFFECTIVITY 24-00-00 Page 8May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 456EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - AC/DC BUS OFF WARNING LOGICS - DC ESSTMUELBY01-P04 LEVEL 3
EFFECTIVITY 24-00-00 Page 9May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 457EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBY01 LEVEL 3
EFFECTIVITY 24-00-00 Page 10May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 458EFFECTIVITYALL
24 - ELECTRICAL POWER
24-41-00 CFDS/ELECTRICAL POWER INTERFACE- AC GENERATION INTERFACES
CONTENTS:Generator Control Unit/Ground Power Control UnitGround Power Control Unit/Centralized Fault DisplaySystem
TMUELBV01 LEVEL 3
EFFECTIVITY 24-41-00 Page 1May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 459EFFECTIVITYALL
ECAM ELECTRICAL POWER INTERFACES - AC GENERATION INTERFACES
GENERATOR CONTROL UNIT/GROUND POWER CONTROL UNIT
The GPCU is the interface between the GCUs and theCFDIU.The Ground Power Control Unit receives the faultinformation from the Generator Control Units, compilesthem with its own failures and transmits them to theCentralized Fault Display Interface Unit.The GPCU receives hexadecimal coded fault informationthrough RS422 data links and transmits a failure listin clear language.
TMUELBV01-T01 LEVEL 3
EFFECTIVITY 24-41-00 Page 2May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 460EFFECTIVITYALL
CFDS/ELECTRICAL POWER INTERFACE - AC GENERATION INTERFACES - GCU/GPCU
TMUELBV01-P01 LEVEL 3
EFFECTIVITY 24-41-00 Page 3May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 461EFFECTIVITYALL
CFDS/ELECTRICAL POWER INTERFACE - AC GENERATION INTERFACES
GROUND POWER CONTROL UNIT/CENTRALIZED FAULT DISPLAYSYSTEM
The Ground Power Control Unit transmits the faultmessage in clear english language to the CentralizedFault Display Interface Unit by an ARINC 429 outputbus.The maintenance test can be performed only on groundwith engines shut down. It is initiated either:
- automatically at each GPCU power-up- or manually from the MCDU
TMUELBV01-T02 LEVEL 3
EFFECTIVITY 24-41-00 Page 4May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 462EFFECTIVITYALL
CFDS/ELECTRICAL POWER INTERFACE - AC GENERATION INTERFACES - GPCU/CFDS
TMUELBV01-P02 LEVEL 3
EFFECTIVITY 24-41-00 Page 5May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 463EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUELBV01 LEVEL 3
EFFECTIVITY 24-41-00 Page 6May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 464EFFECTIVITYALL
24 - ELECTRICAL POWER
24-00-00 CFDS SPECIFIC PAGE PRESENTATION
CONTENTS:Transformer Rectifier Unit(TR)TR Effective ResetTR Impossible Reset
TMUELSP02 LEVEL 3
EFFECTIVITY 24-00-00 Page 1Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 465EFFECTIVITYALL
CFDS SPECIFIC PAGE PRESENTATION
TRANSFORMER RECTIFIER UNIT (TR)
TR1, TR2 and TR3 have the same function.Thus, only TR1 is shown on the MCDU.The Transformer Rectifier protection modulede-energizes the DC bus control contactor in case ofno current flow (1A/TD=500ms) or overheat detection(171°c).When the fault disappears, the TR remains deactivated:a RESET action is necessary to reactivate the TR.2 cases are possible:
- RESET effective,- RESET impossible.
TR EFFECTIVE RESET
If the fault detected by the TR1 protection module hasdisappeared, the TR1 reset is effective, the TR1protection module energizes TR1 control contactor.
TR IMPOSSIBLE RESET
If the fault detected by the TR1 protection module isstill active, TR1 RESET is impossible, the TR1 controlcontactor stays de-energized (a trouble shootingprocedure is necessary).
Note: If the CFDS is not available, the TR protectionmodule can be reset from the pushbutton locatedin the avionics bay.
TMUELSP02-T01 LEVEL 3
EFFECTIVITY 24-00-00 Page 2Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 466EFFECTIVITYALL
CFDS SPECIFIC PAGE PRESENTATIONTMUELSP02-P01 LEVEL 3
EFFECTIVITY 24-00-00 Page 3Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 467EFFECTIVITYALL
THIS PAGE INTENTIONALLY BLANK
TMUELSP02 LEVEL 3
EFFECTIVITY 24-00-00 Page 4Oct 31/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL24 ELECTRICAL POWERMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 468EFFECTIVITYALL