![Page 1: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/1.jpg)
A Practical Guide toLow Frequency Magnetic Shielding
STUART KOCHVice President of Technical Products
Amuneal Manufacturing Corp.Philadelphia, PA
![Page 2: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/2.jpg)
A Practical Guide toLow Frequency Magnetic Shielding
• Introduction to Amuneal
• Typical Magnetic Shielding Projects
• Common Terms in Magnetic Shielding
• The Major Magnetic Shielding Mechanisms
• Shield Design Considerations
• Fabrication and Handling
• Questions, Comments, and Discussion
![Page 3: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/3.jpg)
Introduction to Amuneal
![Page 4: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/4.jpg)
Industries and Technologies Supported
• Particle and Nuclear Physics
• Atomic Magnetometry
• Medical Systems
• Metrology
• Wafer Processing Equipment
• Microscopy
• Aerospace and Defense
• Astrophysics
• Biomagnetics
![Page 5: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/5.jpg)
Magnetic Shields of All Sizes
![Page 6: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/6.jpg)
Common Magnetic Shielding Terms
“The Beginning Of Wisdom Is ToCall Things By Their Right Names”
. . . . Ancient Chinese Proverb
![Page 7: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/7.jpg)
Common Magnetic Shielding Terms
• Field Strength (H)
• Flux Density (B)
• Frequency (F)
• Permeability (µ)
• Saturation (Bs)
• Attenuation (A)
![Page 8: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/8.jpg)
Field Strength (H)(Oe, mOe, A/M)
Field strength depends on the intensity level of the source and its distance from the shield.
![Page 9: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/9.jpg)
Flux Density (B)(G, mG, T)
Flux density measures lines of flux per square centimeter.
![Page 10: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/10.jpg)
Permeability (µ=B/H)
Permeability measures the capacity of a material to provide a flux path.
![Page 11: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/11.jpg)
Permeability Factors
• Manufacturers’ µ data on rings, not shields
• Flux density evenly distributed and measurable
• Known factors: diameter, length, spacing, material thickness, frequency, etc.
• Unknown factors: end caps, holes, stress, seams, joints, doors, furnace loading variation, material lot variation, etc.
![Page 12: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/12.jpg)
![Page 13: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/13.jpg)
B H Curves
![Page 14: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/14.jpg)
Permeability vs. Thickness
![Page 15: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/15.jpg)
Saturation (Bs)
Saturation is the maximum level of magnetic flux that a given material can conduct.
![Page 16: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/16.jpg)
Saturation
• Assumes high permeability (µ) material
• Flux lines which are within 2 radii from the center of the
shield will be pulled into the shield material
• The shield will not saturate as long as 𝑩𝒔𝒂𝒕 >𝑩𝒂𝒑𝒑𝒍𝒊𝒆𝒅 ∗ 𝟐𝒓
𝑻
𝑩𝒎𝒂𝒕′𝒍 =𝑩𝒂𝒑𝒑𝒍𝒊𝒆𝒅 ∗ 𝟐 𝑺𝒉𝒊𝒆𝒍𝒅 𝑹𝒂𝒅𝒊𝒊
𝑴𝒂𝒕𝒆𝒓𝒊𝒂𝒍 𝑻𝒉𝒊𝒄𝒌𝒏𝒆𝒔𝒔
![Page 17: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/17.jpg)
Frequency (f)Permeability @ B40 vs. Frequency and Material Thickness
Permeabilityaffects the overall shielding factor as a function of frequency and material thickness.
![Page 18: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/18.jpg)
Major Magnetic Shielding Mechanisms
• Flux Shunting– Ferromagnetic Materials
– Function of Permeability
• Eddy Currents– Conductive Materials
– Function of Frequency
![Page 19: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/19.jpg)
Magnetic Shield Design Considerations
• Magnetic Field Intensity and Frequency
• Material Selection
• Shield Configuration and Geometry
![Page 20: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/20.jpg)
Common Magnetic Shielding Materials
Material Saturation Permeability (µ ) Resistivity
(Gauss) Mill Cert / Effective (µohm-cm)
Amumetal 8,000 60,000 15,000 72
Amumetal 4K* 9,000 70,000 17,500 72
ULCS/LCS 22,000 1,000 500 12
Aluminum N/A 1 1 5
Copper N/A 1 1 2
* Cryogenic application
![Page 21: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/21.jpg)
University of MarylandFour Layer Magnetic Shield Components for the Study of
Intrinsic Magnetic Characteristics of Superconductors
![Page 22: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/22.jpg)
Permeability vs. Operating Temperature
![Page 23: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/23.jpg)
Shield Configuration / Geometry
• Shape
• Dimensions
• Number of Layers
• Seams and Connections
• End Effects
![Page 24: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/24.jpg)
![Page 25: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/25.jpg)
![Page 26: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/26.jpg)
100
1000
10000
100000
1000000
0 1 2 3 4 5
Att
enuation
Number of Shield Layers
Attenuation as a Function of Layers
![Page 27: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/27.jpg)
![Page 28: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/28.jpg)
![Page 29: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/29.jpg)
Seams
![Page 30: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/30.jpg)
Joiner Bands
![Page 31: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/31.jpg)
Stanford University Atomic Equivalence Experiment
![Page 32: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/32.jpg)
“End Effects”
![Page 33: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/33.jpg)
End Caps
![Page 34: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/34.jpg)
Three Layer Magnetometer Shield with Access Door and Flanged Lid
![Page 35: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/35.jpg)
LAWRENCE BERKELEY
NATIONAL LABORATORY
Advanced Light Source
MAGNETIC SHIELD FOR THE
THIRD GENERATION PHOTON
EMISSION ELECTRON
MICROSCOPE (PEEM3)
![Page 36: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/36.jpg)
Magnetic Shield Fabrication and Handling
• Sheet Metal....Not Machining!
• Hydrogen Annealing
• Handle Like Glass
![Page 37: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/37.jpg)
![Page 38: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/38.jpg)
SEM Photos of Grain Boundary Grooves in Amumetal
Figure 1: 1,000x Magnification Figure 2: 2,100x Magnification
![Page 39: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/39.jpg)
Attenuation Testing
![Page 40: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/40.jpg)
![Page 41: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/41.jpg)
![Page 42: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/42.jpg)
Effects of MishandlingDrop Test Data
0.000
0.200
0.400
0.600
0.800
1.000
1.200
1.400
1.600
1.800
Drops from 30.5 cm
Drops from 61.0 cm
Drops from 93.0 cm
µ/1
05
![Page 43: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/43.jpg)
Demagnetization
![Page 44: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/44.jpg)
Procedure for Cylinder Demagnetization
𝐻 =𝑁𝐼
𝐿𝑓𝑒
Method: This method allows varying the current in order to minimize the number of coil windings.Using a VARIAC, ramp up slowly to the selected current over 15 seconds, hold for 15 seconds, and then ramp down to zero amps over 15 seconds.Repeating the cycle three times will optimize demagnetization. Additional cycles beyond that tend to have little, if any, benefit.
H = Magnetization field in A/cm (1.0 A/cm for Amumetal)N = Number of coil windingsI = Current AmperesLfe = Outer circumference of cylinder in cm
![Page 45: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/45.jpg)
Major Cost Factors
• Material Cost
• Shield Dimensions and
Complexity
• Engineering
• Fabrication
• Hydrogen Annealing
• Ease of Assembly and
Installation
![Page 46: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/46.jpg)
One final note…
• The terms
• How magnetic shielding works
• The right material for your application
• Important design considerations
• Does the shield meet my attenuation needs?
• Why hydrogen annealing is so important
• And please remember to get us involved early in your project.
![Page 47: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/47.jpg)
SOME REFERENCES FOR LOW FREQUENCY MAGNETIC SHIELDING (1)
• “A New Estimation of the Axial Shielding Factors for Multishell Cylindrical Shields”, E. Paperno, H. Koide, I. Sasada, Journal of Applied Physics, Vol. 87, Nbr 9, 1 may 2000
• “Amuneal’s Cryoperm Magnetic Shielding”, 4 pages. COLD FACTS Buyer Guide December 2004 Volume 20, Number 5
• “Application of Atomic Magnetometry in Magnetic Particle Detection”, S. Xu, M. H. Donaldson, • A. Piners, S.M. Rochester, D. Budker, V. V. Yashchuk. Applied Physics Letters 89, 224105 (2006)
• ASTM A753-02 “Standard Specification for Wrought Nickel-Iron Soft Magnetic Alloys”, 6 pages. American Society for Testing and Materials. 2002
• “Conventional Magnetic Shielding”, T. J. Sumner, J. M. Pendlebury, K. M. Smith, J. Phys. D: Applied Physics 20 (1987) 1095-1101
* Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National Superconducting Cyclotron Laboratory, Michigan State University
• Cryoperm 10 Data Set HT-EM, 11 pages. Vacuumschmelze GmbH
• “Custom Magnetic Shielding for Low Temperature Applications”, 4 pages. Amuneal Manufacturing Corporation
• “Definitive Guide to Magnetic Shielding”, 27 pages. Amuneal Manufacturing Corporation
![Page 48: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/48.jpg)
MORE REFERENCES FOR LOW FREQUENCY MAGNETIC SHIELDING (2)
• “Design of the Magnetic Shield for TRASCO Low Beta Elliptical Cavities”, P. Pierini, S. Barbanotti, L. Monaco, N. Panzeri, INFN Milano - LASA
• “Experience With Magnetic Shielding of a Large Scale Accelerator”, S. Nagaitsev, C. Gattuso, S. Pruss, J. Volk, FNAL
• “Ferromagnetism”, Richard M. Bozorth, IEEE Press, 1951, Rev 1978, (968 pages)
• “Magnetic Shielding”, Vacuumschmelze GmbH Publication FS-M9, 1989 (46 pages)
• “Magnetic Shielding Theory and Practice”, L. Maltin and A. Kamens, in ITEM EMC Directory & Design Guide, 2001 (3 pages)
• “Magnetic Shields”, Albrecht Mager, IEEE Transactions on Magnetics, March 1970
• “Material Efficiency in Magnetic Shielding at Low and Intermediate Frequency”, U. Adriano, O. Bottauscio, M. Zucca, IEEE Transactions on magnetics, Vol. 39, No. 5, September 2003
• “Optimal Shell Separation for Closed Axial Cylindrical Magnetic Shields”, Eugene Paperno, SaeePeliwal, Michael V. Romalis, Anton Plotkin, Journal of Applied Physics 97, 10Q104 (2005)
• “Optimal Three-Layer Cylindrical Magnetic Shield Sets for Scientific Applications”, E. A. Burt and C. R. Ekstrom, Review of Scientific Instruments Vol 73, Number 7,July 2002, 2699-2704
![Page 49: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/49.jpg)
MORE REFERENCES FOR LOW FREQUENCY MAGNETIC SHIELDING (3)
• “Principles of Quasistatic Magnetic Shielding with Cylindrical and Spherical Shields”,J. F. Hoburg, IEEE Transactions on Electromagnetic Compatibility, Vol 37, No. 4, November 1995
• “Review of Magnetic Properties of Fe-Ni Alloys”, Gilbert Y. Chin, IEEE Transactions on Magnetics, Vol MAG-7, No. 1, March 1971
• “Simple Formula for Multiple Mu-metal Shields”, D. Dubbers, Nuclear Instruments and Methods in Physics Research A243 511-517 (1986)
• “SNS Cavity Intrinsic Quality Factor Requirements Based on a Cryomodule Magnetic Shielding Calculation”
• Sun An, SNS-NOTE-CRYO-120, March 2004
• “Soft Magnetic Materials Handbook: Fundamentals, Alloys, Properties, Products, Applications”, Richard Boll (ed.) Vacuumschmelze GmbH, 1979 (353 pages)
• “Systematic Design of Magnetic Shields”, E. Baum and J. Bork, Journal of Magnetism and Magnetic Materials 101 (1991) 69-74
• “The Drop Test: Deterioration of Magnetic Shielding Due to Mishandling or Abuse”, S. M. Kamens and R. M. Koren, in EMC Technology 1987
• Westinghouse Designers Handbook: The When, Why and How of Magnetic Shielding, C. H. Arendt, Jr., Westinghouse Electric Corporation publication, (1966) 35 pages
![Page 50: A Practical Guide to Low Frequency Magnetic Shielding · * Cryomodule Design for a Superconducting LINAC with Quart-Wave, Half-Wave and Focusing Elements”, M. Johnson et. al, National](https://reader033.vdocuments.us/reader033/viewer/2022042214/5eba0a8c8a4282473c347ffb/html5/thumbnails/50.jpg)
For a complimentary copy of today’s presentation and the list of reference
documents, please visit:
www.amuneal.com/workshop