1
A Methodology for the Simultaneous Design of
Supply and Signal Networks
Haihua Su† Jiang Hu⋆ Sachin S. Sapatnekar‡ Sani R. Nassif†
†IBM Corp.
11400 Burnet Rd.
Austin, TX 78758
{haihua,nassif}@us.ibm.com
⋆EE Dept., Texas A&M Univ.
320G WERC
College Station, TX 77843
‡ECE Dept., Univ. of Minnesota
200 Union St. SE
Minneapolis, MN 55455
Abstract
We present an early stage global wire design methodology that simultaneously considers
the performance needs for both signal lines and power grids under congestion considerations.
An iterative procedure is employed in which the global routing is performed according to
a congestion map that includes the resource utilization of the power grid, followed by a
step in which the power grid is adjusted to relax the congestion in crowded regions. This
adjustment is in the form of wire removal in noncritical regions, followed by a wire sizing
step that overcomes the voltage noise after wire removal and a wire width resizing that
meets the maximum current density constraint. Experimental results show that the overall
routability can be significantly improved while the power grid noise is maintained within
both the voltage drop and current density constraints.
This work was supported in part by the NSF under award CCR-0098117 and by the SRC under contract 99-TJ-714.
-
2
I. Introduction
The role of interconnect has become increasingly critical in nanometer design and the
need to meet stringent performance constraints has resulted in strong contention for scant
routing resources. A major consumer of these resources is the power distribution network,
which must be designed to ensure reliable Vdd and ground levels, and therefore requires the use
of dense grids. On the other hand, global wires also compete for the same routing resources,
as they often require shortest-path routes to meet their own performance requirements.
Traditionally, these two have been designed independently, with the routing needs for a
regular power grid being determined first, after which the remaining resources are calculated
to provide routing resource budgets for the signal nets.
As the number and criticality of global signal wires becomes more dominant, such a
methodology becomes unsustainable as the initial budgets may often be entirely unreason-
able, so that ad hoc changes at the end are inadequate to meet the performance and/or
routing completion targets. Moreover, the use of a completely regular supply grid cannot
be defended in the face of large variations in the voltage drops on a regular grid at different
points of the chip. Therefore, in nanometer design, there is a strong need for a unified ap-
proach to the design of signal wires and power grids, with an integrated approach to routing
resource management.
The considerations involved in the design of the power grid and the signal wires are quite
different. Since the former is intended to provide a reliable Vdd or ground voltage throughout
the circuit, a typical grid contains a dense and regular distributed mesh-like structure that is
designed to meet constraints on parameters such as the IR drop noise. Since this entails the
use of numerous wide wires, the routing resources used by the power grid are considerable.
On the other hand, signal nets are typically tree structures that are designed to connect a
-
3
source to a number of sinks under constraints related to the timing criticality of the net. The
complexity of routing signal nets is exacerbated by their sheer number, so that the routes
for any individual net cannot be determined without considering the contributions of the
others to the congestion. Most often, global signal wires seek out shortest-path connections,
although detours are often essential to navigate around regions of high traffic.
While it is convenient to build a regular power grid with a constant pitch (defined as the
distance between adjacent wires in the grid), some degrees of freedom exist and it is desirable
that they be exploited. For instance, the density of the grid in different parts of the chip
need not necessarily be the same, since the use of a denser grid near hot spots with strong
current sinking requirements would help in providing reliable voltages, while a sparser grid
is adequate in less critical regions. This may further be combined with considerations for
routing signal nets, so that in regions where the demand for routing resources from signal
nets is high, a sparser power grid may be used as long as the performance constraints on the
supply and ground lines can be met; likewise, signal nets are well advised to avoid the hot
spots of the chip if possible, since these may need a locally dense power grid.
Strictly speaking, the results of global routing have an effect on the demands on the power
grid, since the locations of buffers are determined by the routes that are chosen by signal
wires. Since the number of buffers can be extraordinarily large in nanometer technologies,
buffers can collectively be nontrivial contributors to power grid current. However, these
effects can be controlled at the methodology level. For example, using the model of [1], where
buffers are predistributed and sprinkled into various functional blocks, we may estimate the
current drawn by the buffers and include it in the current drawn by the functional block.
As long as the routing is buffer-aware and deliberately seeks out regions with high buffer
availability, the use of signal routing-independent current waveforms for the functional blocks
-
4
can be justified in generating an initial power grid design. Later in the design process, wire
widening and decap assignment may be used to overcome second-order effects.
The idea of managing wire congestion in signal routing has long been a significant ob-
jective in global routing. Various congestion-driven techniques include sequential routing
(e.g., [6]), rip-up-and-reroute (e.g., [24]), and multicommodity flow based methods (e.g., [20])
have been proposed. Most of these techniques aim at solving the problem solely at the rout-
ing stage, assuming that the total routing resources are fixed. Recent publications [1, 11]
have presented techniques for simultaneous global routing and resource allocation under
performance constraints.
Power grid optimization techniques have also been studied in [21, 23, 26]. All of these
aim at minimizing total power wire area subject to the voltage drop and/or electromigration
constraints, formulating the problem as a nonlinear program. Mitsuhashi and Kuh presented
a mesh-based power/ground network topology optimization method for cell-based VLSIs
in [15]. While [23] solves the problem by relaxing it to a sequence of linear programs, both [21]
and [26] have employed gradient-based nonlinear optimization techniques. The formulation
in [21] handles the transient voltage drop noise under worst-case switching events, while [26]
considers the worst-case voltage drop and current density. The work in [13, 14] develops
techniques for shield insertion to control inductive effects, including methods that minimize
both signal and power routing.
To the best of our knowledge, no published work performs a concurrent optimization
of the power grid along with signal wires under routing congestion constraints, and this
is the subject of the work presented in this paper. Our proposed congestion-driven flow is
illustrated in Fig. 1. The dashed rectangle corresponds to a more conventional global routing
flow, where the routing budgets for power grid lines are used to allocate routing resources
-
5
Signal
Power Wire Removal
PowerGrid or Cells
MacrosNetlist
GlobalRouter
Congestion Map
+ Power Grid Sizing
+ Power Grid Resizing
Fig. 1. Congestion-driven power grid design and global routing.
for the signal lines, and these budgets are frozen throughout the design. In essence, our
approach presents a new flow for early stage global wire planning that adds a feedback
loop that permits the readjustment of the signal routing budgets by altering the power grid
appropriately.
Our procedure begins by constructing the initial Steiner trees for the global signal wires
without considering the congestion contributions of the power grid. The initial power grid
is provided as an input to the algorithm (and may, perhaps, be a regular grid or a manually
designed grid) and is assumed to be dense enough to sustain the switching activities of
the functional blocks in the chip. Our proposed iterative scheme alternately (i) reroutes
the global signal wires, and (ii) adjusts the supply network to de-congest regions of high
contention where the voltage drop constraints are easily satisfied. The adjustments made
to the power grid consist of wire removal from the grid in congested regions, sizing of the
power grid to compensate for this removal, and wire width resizing to meet the maximum
current density limit. The complexity of power wire sizing cannot allow the adjustment
procedure to be applied to the full on-chip power grid. Instead, a coarsened grid is usually
used to approximate the performance of the full grid in early stage global wire planning.
-
6
Our approach incorporates a tight coupling between power grid adjustments and the routing
of signal wires to exploit the altered congestions that result from these adjustments, and
aims to solve problems with severe congestion constraints where conventional techniques are
inadequate.
The remainder of the paper is organized as follows. Section II discusses the power grid-
aware congestion estimation method and the global routing procedure. Next, an efficient
power grid noise analysis technique is briefly described in Section III, followed by details
of the heuristic power wire removal and sizing scheme in Section IV. The overall flow of
the algorithm is summarized in Section V, and experimental results on several benchmark
circuits are shown in Section VI. Finally, Section VII concludes the paper.
II. Power grid-aware signal routing
As in global routing, we tessellate the entire chip into an array of grid cells, as shown
in Fig. 2(a), and use the wiring information across the boundaries between neighboring grid
cells to estimate the signal wire congestion distributions. We denote the width, in µm, of a
boundary b between two neighboring grid cells as W (b). This width represents the limited
resources that must be shared on each layer by the supply lines and the signal lines that
traverse the boundary, as shown in Fig. 2(b). In other words, the number of wires crossing
b is inherently limited by the width W (b), and W (b) may partly or wholly be occupied by
the crossing wires.
We represent the total width occupied by power grid wires on boundary b as P (b). If a
power grid wire pi has a track width of w(pi), which includes its wire width and the required
spacing from an adjacent wire, and there are a set of such wires, p1, p2, ...pm, that cross b,
then P (b) =∑m
i=1 w(pi) represents the space that is unavailable for signal wires to cross
the boundary. Therefore, we subtract this quantity from the boundary width to obtain the
-
7
space available for signal wires as W (b)−P (b). Typically, a uniform track width w̄ is applied
to all the signal wires in the congestion estimation or global routing stage. Hence, signal
wire congestion is often expressed in terms of the number of wiring tracks and the number of
tracks available for signal wires is T (b) = ⌊W (b)−P (b)w̄
⌋. If there are S(b) signal wires that cross
a boundary b, then the overflow on b is max(0, S(b)−T (b)). All tile boundaries with positive
overflow values form a congestion map for a chip. The wire density at b is represented as
S(b)/T (b), measuring the congestion of b. A common objective for global routing is to ensure
that there is no boundary with the wire density greater than one, i.e., S(b) ≤ T (b).
(a) (b)
P/G wire
Signal wire
Boundary width
Fig. 2. Wire congestion estimation based on tessellation on a chip.
In this work, the topology selection for the power grid is tightly coupled with the re-
quirements of global routing for signal wires, and it is important to estimate the congestion
contribution of the signal wires by implementing a fast global routing procedure. The tech-
nique used for this purpose is described in the remainder of this section, but it may be noted
that this procedure may be replaced by any other computationally efficient method that
shares a similar goal.
At the beginning of the algorithm, we perform a coarse global routing of all signal nets
to obtain an estimate of the distribution of signal wire congestion at various boundaries,
and feed this information to power/ground optimizer. The global routing technique used
here is similar to [1], where a Steiner tree is initially constructed for each signal net using
-
8
the AHHK algorithm [2] without considering congestion. The AHHK algorithm itself uses
a two-step procedure for each net: it first constructs a minimum cost spanning tree for the
net; this is then converted to a Steiner tree via a greedy overlap removal process. After
the initial Steiner trees have been constructed, an iterative rip-up-and-reroute procedure is
applied to further reduce the wire congestion. The outer loop, consisting of signal routing
followed by power grid optimization, is repeated iteratively until the constraints are satisfied
or no further improvement is possible. In each iteration, the global routing solution from
the previous iteration is used as a starting point for the rip-up-and-reroute procedure, with
updated congestion values being used to direct the routing.
The rip-up-and-reroute procedure processes each net sequentially using the fixed net
ordering heuristic proposed in [16], continuing until the maximum wire density is no greater
than one, or after two complete iterations, since the congestion reduction after the second
iteration is limited. Each net undergoing rip-up-and-reroute is entirely deleted and then
rerouted using an algorithm similar to the min-max tree algorithm in [6].
A min-max tree is a Steiner tree such that its maximum edge cost among all the edges
is minimized. This tree is built on a tile graph that is the dual of the tessellation, where
vertices correspond to tile rectangles and edges are used to connect the vertices corresponding
to adjacent tiles in the graph. The weight on an edge is based on the wire density, so that
for an edge that crosses over a boundary(edge) b, this is defined as:
weight(b) =
S(b)+1T (b)−S(b)
, S(b) < T (b)
LS(b)T (b)
, otherwise(1)
where L is a large number. Therefore, if the capacity is not exceeded, the weight is the
number of wires crossing b, divided by the number of available tracks that remain. This is
found to be particularly effective since it increases the penalty of using the boundary as the
resource usage approaches the full boundary capacity, and beyond that, presents successively
-
9
larger penalties for capacity violations.
III. Power supply noise analysis
As is usually done in power grid analysis work [4, 5], we use the following linear circuit
model to analyze the voltage drop noise of the power distribution network:
• The power grid is modeled as a resistive mesh.
• The cells/blocks are modeled as time-varying current sources connected between the
power and ground plane.
• Decoupling capacitors are modeled as single lumped capacitors connected between
power and ground.
• The top-level metal is connected to a package modeled as an inductance connected to
an ideal constant voltage source.
This model leads to a large-scale linear circuit for power grid analysis, which is efficiently
analyzed using a technique outlined in Appendix A. The wire width optimization procedure
for the supply network, described in Section B, also requires the computation of gradients,
and this is performed using the simulation framework. Specifically, the transient adjoint
sensitivity analysis technique to calculate the sensitivity of the noise metric with respect to
every tuning parameter, which, in our case, is the width of every power wire.
The noise and sensitivity analysis techniques used here are substantially similar to our
work on decoupling capacitor (decap) placement [22] and have therefore been described only
very briefly here. The only difference is that the tuning parameters in decap placement are
the decap values, while in this work, the tuning parameters correspond to the width of each
power grid wire. Consequently, current waveforms instead of voltage waveforms must be
calculated for adjoint sensitivity computations in this work.
-
10
IV. Power grid design scheme
Starting with a dense grid that is guaranteed to meet the constraints on the supply
network, our scheme iteratively sparsifies the grid to ease the wire congestion. In each
iteration of the loop in Fig. 1, the power grid is adjusted using a three-step technique:
• In the first step, a wire removal heuristic is used to make the grid less dense in some
regions, with due consideration paid to both the congestion information and the power
grid noise.
• In the next step, a voltage drop based wire sizing step that adjusts the sizes of the
remaining wires in the grid to compensate for the loss of wires.
• This is followed by an additional wire width widening step to meet the maximum
current density limit constraint.
Therefore, our procedure ensures satisfactory performance of the power grid while utilizing
just enough routing resources, so that the resources available to signal routing are maximized.
The idea of altering the topology to meet current density constraints has been studied in [15],
but our work has several enhancements over this method. Firstly, our method is explicitly
congestion-driven and incorporates both signal and supply net constraints in a concurrent
optimization. Unlike their method, the wire sizing approach presented in this section does
not change the topology of the network, but that is performed in the wire-removal procedure.
Secondly, our method analyzes transient noise while [15] operates under a DC circuit analysis.
Lastly, we differ in that we use a simplified solution that separates the electromigration
solution from the nonlinear programming formulation, and solve it heuristically through a
wire width widening that is applied as a post-processing step, since the transient problem is
harder than the DC problem.
-
11
A. Power grid wire removal heuristic
As stated in Section II, the congestion is measured in proportion to the overflow value
on each tile edge. All power wires that lie in congested regions are potential candidates
for removal, except those that lie within hot spots where the voltage drop is significant.
The rationale behind this is that whenever a power wire is removed, the performance of the
overall grid is compromised, and this is all the more noticeable if this wire lies within a hot
spot. Therefore, we define a power wire as critical if the worst-case voltage drop on it is
beyond some specified threshold Vdropth. Critical wires are not candidates for removal even
if they lie in congested regions.
In addition, we use the sensitivity of the total voltage noise integral with respect to each
wire width as the measure of criticality of each non-critical power wire. The sensitivity, at
the same time, is used to determine the gradients in wire sizing discussed in B. Given several
candidate power wires across one tile boundary with its overflow value larger than OVth, the
criticality of each wire determines an optimal order of removal for these wires.
The power wire removal heuristic proceeds as follows. First, the tile boundaries are
sorted in decreasing order of their overflow values. Next, a transient adjoint sensitivity
analysis is performed and all the wires are sorted according to the sensitivity values. This
sorting arranges all non-critical power wires according to their importance to the overall
performance of the power grid. Next, non-critical power wires are removed in the order of
the sorted tile boundaries, provided that the overflow value at the boundary is larger than
OVth. Several practical considerations must be taken into account. Firstly, the power wire
removal process should be accompanied by dynamically updating the overflow value on every
tile edge, so that subsequent wire removal is based upon the updated congestion information.
Secondly, a reasonable number of power wires must be removed in each iteration, and this
-
12
depends on the values of OVth and Vdropth. Since the choice of these numbers is necessarily
empirical and cannot be entirely relied on, we assert an upper bound for the number of power
wires to be removed in any iteration to conserve the amount of computation required in the
wire sizing step discussed in Section B. In our experiments, this upper bound is chosen to
be 4 ∼ 6% of the total number of power wires. If a set of non-critical power wires are across
one tile boundary, remove them in their increasing order of the sensitivity-based importance
metric defined above. Through this rule, non-critical power wires with lower importance are
removed first.
(a) (b)
5 6
12 3 4
Fig. 3. Heuristic power wire removal.
Fig. 3 illustrates a simple example of a power grid before and after a wire removal step.
The three dark lines denote congested tile boundaries whose overflow values exceed OVth.
The overflow values on the three boundaries are proportional to the line widths shown in
the figure. The two shaded areas on the power grid represent regions where the worst-case
voltage drop is larger than Vdropth. There are a total of six wires, marked 1 through 6,
that cross the congested boundaries. Since four of them (wires 1, 2, 4 and 6) are critical
wires, they are not candidates for removal. The boundaries are processed in the order of
their congestion, so that first wire 3, and then wire 5, is removed from the grid. If there
had been multiple candidates at any point, the one with the lowest importance metric would
have been removed first. After wire removal, the area of the shaded region is increased due
-
13
to the increased voltage drop, and the overflow values on every tile edge traversed by wires
3 and 5 are accordingly updated, and this translates into dark edges of reduced thickness in
Fig. 3(b).
B. Voltage-constrained power grid sizing
B.1 Problem formulation
The second step in the adjustment of the power grid is related to sizing the wires in the
grid to compensate for the increased voltage drop after the wire removal step. The problem is
directly formulated as a nonlinearly constrained nonlinear programming problem as follows:
minimize Area(wj) =Nwire∑
j=1
lj × wj
subject to wmin ≤ wj ≤ wmax, j = 1 · · ·Nwire (2)
and Z(wj) < ǫ
where ǫ is a very small number, and Nwire is the total number of wires in the grid.
The objective function that minimizes the total power wire area is consistent with the
goal of congestion reduction. The first constraint restricts every power wire width to lie
within a realistic range that is technology dependent. The second constraint requires the
definition of the parameter Z, which is an effective metric for noise measurement that was
proposed in [7]. This metric finds the integral of the noise violation and is zero if all con-
straints are satisfied. It punishes larger violations more severely than minor violations, and
since it incorporates both the magnitude and time axes together, it is observed to be more
practical than one that considers only the worst-case noise violation.
In the context of power grid analysis, the noise at a node can be efficiently measured
using the integral of the voltage drop below a user specified noise ceiling as:
zj(p) =∫ T
0max{NMH − vj(t, p), 0}dt
-
14
0 tte Tts
NMH
Vdd
90%Vdd
Vj(t, p)
Fig. 4. Illustration of the voltage drop at a given node in the Vdd power grid. The area of the shaded regioncorresponds to the integral z at that node.
=∫ te
ts
{NMH − vj(t, p)}dt (3)
In Eqn. (3), p represents the tunable circuit parameters which, in our case, are the widths of
the power grid wires. This idea is pictorially illustrated in Fig. 4, which shows the voltage
waveform of one node on the Vdd grid. The noise metric for the entire circuit is defined as
the weighted sum of all of the individual node metrics:
Z =K
∑
j=1
ajzj(p), aj =zj
∑Kj=1 zj
, (4)
where K is the number of nodes, and the weight aj magnifies node j with larger voltage
drop noise.
The nonlinear constraint function Z can be obtained by transient analysis of the power
grid circuit, and its sensitivity with respect to all the variables wj can be calculated using
the adjoint method discussed in Appendix B.
B.2 Optimization scheme
We use a standard Sequential Quadratic Programming (SQP) solver [3, 10] to solve
the optimization problem. This solver requires users to provide subroutines to evaluate
the objective and constraint functions and their derivatives with respect to each decision
variable. The evaluations that are required for the SQP solver are illustrated in Fig. 5.
-
15
Objective function
A = Σliwi
Jacobian∂Z∂wi
from transientGradient∂A∂wi
= Σli
Construct adjoint circuitand add current sourcesto failure nodes
simulation of adjoint circuit
Constraint function
Z from transientsimulation of original circuit
SQP solverUpdate wi
Fig. 5. Power grid sizing procedure.
Practically, it is observed that the SQP solver converges slowly near the optimum. How-
ever, an approximate convergence is sufficiently good for our purposes, so that we require Z
to be near-zero rather than exactly zero by choosing a sufficiently small ǫ.
C. Current Density Based Power Grid Re-sizing
Electromigration is a concern related to the reliability of on-chip power grid since it
directly impacts the lifetime of a chip. Empirically, the mean time to failure, a measure
of the chip lifetime, has been found to vary exponentially with the average current density
over time. For the purposes of our implementation, a simple current density model, which
ignores the skin effect, is used (this may be substituted by more sophisticated models)
and the currents are assumed to flow through the entire cross-section of each wire. The
maximum current density of the entire grid, Idmax , is the peak current density among all the
wire segments in this grid. A hard maximum current density limit, Jmax, is asserted for the
power grids in all metal layers. In order to guarantee that all the wires satisfy the current
density limit, we resize all the wires using
wnew =
wold ×IdmaxJmax
,
wold,
Idmax > Jmax
Idmax ≤ Jmax(5)
-
16
This is a heuristic way to deal with current density violation, working under the assumption
that the optimal solution that meets the integral voltage drop constraint provides a good
starting point for optimizing the current density, which we found to be a valid assumption in
practice. Moreover, it was found that since the current density violations are typically local
in nature, only a small number of wires must be resized in this step, and the overall wire
area, and hence the voltage drop and current distribution, are not impacted significantly.
We iteratively analyze the power grid again to update the current density until no violation
can be found. Our experiments have shown that a few iterations are sufficient to remove all
the current density violations.
V. Overall flow of the algorithm
Having described all of the individual pieces of the algorithm, we now outline the overall
flow of the procedure. The starting point is a given tessellation of a chip and a given initial
power grid construction, and the sequence of steps can be summarized as follows:
1) An initial power-grid aware global routing step is carried out to route the signal
nets. Each net is first routed without considering congestion, followed by an iterative
rip-up-and-reroute, described in Section II, using the updated congestion information.
2) Based on the routes used by the power grid and the signal routes, a congestion map
is generated and the overflow on each tile boundary is calculated. All tile boundaries
whose overflow value exceeds the threshold OVth are identified and are sorted in
decreasing order of this value.
3) A transient simulation of the power grid is performed to identify critical power wires
on which the worst-case voltage drop is above the threshold, Vdropth.
4) Sort the non-critical power wires in increasing order of the criticality.
5) Based on the congestion map generated in Step 2, non-critical power wires are re-
-
17
moved according to the heuristic described in Section IV A.
6) To compensate for the removal of these wires, the remaining power grid wires are
sized using the nonlinear optimization procedure described in Section IV B and resized
heuristically using the method described in Section IV C.
7) The congestion maps are updated, and the global routing is updated by performing
rip-up-and-reroute based on the new congestions. At this point, the iterative loop
is invoked so that the updated power grid and congestion map are fed back to step
3. The stopping criterion for the iteration is that the maximum overflow should be
no greater than 1, or that no further improvement is possible. The latter is easily
identified if it is detected that the changes in the congestion map after rip-up-and-
reroute are insignificant, and that no further deletion of the power wires is possible.
The initial routing takes O(MN3) time, where N is the number of pins for each net
and M is the total number of nets. The rip-up-and-reroute has a complexity of E log log E,
where E in our case is the total number of tile edges. The complexity of power wire removal
is O(KlogK +PlogP +KPE), where K is the total number of tile edges with negative over-
flow values, P is total number of power wires and E is total number of tile edges. The first
term stands for the complexity of sorting these tile edges, the second term is the worst-case
complexity of sorting the criticality of non-critical power wires, and the third term comes
from the power wire removal and dynamic tile edge overflow update process. The power grid
analysis and sensitivity analysis has the complexity of one LU decomposition and two for-
ward/backward substitutions. In practice, the cost of these computations is just over O(n)
for a sparse positive definite matrix, where n is the total number of nodes and inductance
branches. For a nonlinear optimization problem with w decision variables, advanced imple-
mentations of the SQP solver have O(w2) cost. The complexity of current density-based
-
18
power grid resizing is proportional to the complexity of the transient simulation, which is
O(n). Therefore the worst-case complexity for our wire sizing procedure ends up to be
O(I(n+w2)+Ic(n)), where I is the total number of nonlinear optimization iterations and Ic
is the total number of iterations for the current density-based resizing. The efficiency of the
gradient-based SQP solver relies largely on the initial solution and its distance away from
an optimum. Practically, it is seen that the optimal solution can be reached in a limited
number of iterations. Similarly, the current density violations can be removed within a very
limited number of iterations.
Several assumptions have been made in our flow, and we discuss their implications below.
• Our method always starts with a conservative power grid that meets the power budget.
However, this may introduce a significant amount of routing congestion, and this is
alleviated by our technique. The problem of jointly meeting the power and signal net
constraints does not always have a feasible solution, and the optimal solution returned
by the SQP solver can be considered as a commentary on the quality of the original
design. When the solver ends up with no solution, or when it returns a solution
that satisfies (or nearly satisfies) the voltage drop constraints but utilizes much larger
power grid resources than the original one, this indicates a poor design. In such a
case, the original grid or certain modules of the chip should be redesigned to be able
to meet all the requirements. Similarly, if the solver always returns a solution that
is close to the original grid before the wire removal, routing congestion can barely be
further improved by changing the power grid. In such cases, we will have to either
try to remove a small segment of an entire power grid that crosses the most congested
region and rerun the sizing optimization, or redesign the original power grid using a
different pitch and/or width and restart our flow.
-
19
• Our power grid removal and sizing operates on the entire length of each wire across
the chip. It can easily be extended to remove the portion of a grid that occupies the
most congested region. In this case, one long grid could be split into several shorter
grids during the wire removal process. Furthermore, wire sizing can potentially be
extended to work on wire segments between adjacent nodes. For the purposes of this
paper, we do not address these issues, particularly since they may cause the size of
the problem to increase greatly and may cause other problems with the methodology.
• Our method is directed towards early design planning, and does not attempt to solve
the problem on a full on-chip power grid later in the design. Such a problem is
very different, since the power grid can have up to tens of millions of nodes, where
it becomes infeasible to perform the nonlinear optimization which requires extensive
transient and sensitivity analyses of the power grid circuits. However, for such large
scale problems, our method can be extended by coarsening and widening the original
power grid to some manageable size, and then fed into our flow to find the optimal
grid solution. The fine grid can then be reconstructed according to the total optimal
grid area and local density. This borrows the multigrid idea presented in [12,17,25].
• Our congestion-driven engine will automatically guide global routing into less con-
gested regions of a chip. Buffers are not considered at this early wire planning stange.
This is typically the practice in industrial flows. If buffer effects are to be considered,
generally speaking, making the wiring distribution more evenly will help in distribut-
ing the buffers. Moreover, buffer currents are significantly smaller than block or macro
currents. Therefore, wire sizing can typically compensate the current redistribution
due to the buffer change. Alternatively, our method can easily be adapted by con-
sidering the buffer cost during routing, and by adding the pre-characterized buffer
-
20
currents to the grid during the wire removal and wire resizing phases.
• Power wires are often used to shield signal wires to reduce the crosstalk noise. For
crosstalk-sensitive nets, a wire width inflation ratio can be applied to increase the
cost of these nets, to account for the cost of the shields that can be inserted later on
at the end of our flow. These additional shields will not impact the wiring congestion
because their cost are already counted during routing. On the other hand, the addition
of extra wires can only improve the overall power grid performance.
VI. Experimental results
The power grid analyzer and the global router have both been implemented in C++.
The power grid removal and sizing scheme, and the overall congestion-driven power grid
design and global routing flow has been written using Tcl. The wire size optimization is
performed using an off-the-shelf SQP solver [10]. All experiments are performed on an Intel
Xeon 2.4GHz server with 512M memory running Redhat Linux 9.0. The entire procedure is
encapsulated in a flow called PSiCo (Power-Signal Codesign).
We have tested our flow on seven benchmark circuits obtained from the authors of [1]. All
designs correspond to a 0.18µm technology and a supply voltage of 1.8V. The time-varying
current sources modeling the behavior of each functional block was not originally available in
these benchmark circuits. These waveforms are constructed by modifying current waveforms
from several industrial circuits by adjusting their magnitude according to the area of each
block. However, this is not a critical assumption since our method is applicable to the exact
waveforms where available.
Initially, six layers of regularly distributed power grids with fixed wire widths are gen-
erated for all of these examples, with each layer containing only horizontal or vertical wires.
Since a majority of the global routes are typically seen on the third and fourth metal lay-
-
21
ers, M3 and M4, we perform the global routing and power grid sizing on these two layers,
assuming that the other layers are processed separately. The wire widths on these layers
are assumed to be constrained within the range of 0.8µm and 4µm in our experiments. The
initial power grid is constructed with a constant pitch in M3 and M4 such that under the
given set of time-varying current sources that represent each block, the worst-case voltage
drop on the entire power grid is within a threshold, which in our experiments, is chosen to
be 0.18V. Table I lists the characteristics of each circuit, in terms of the total number of
blocks B and nets N and the tile sizes.
Circuit B N Tilesize
apte 9 77 31x36ami33 33 l12 30x28ami49 49 368 33x34playout 62 1294 30x26ac3 27 200 29x28hc7 77 430 34x39a9c3 147 1148 33x31
TABLE I
Test circuit parameters.
The performance of PSiCo can be described in terms of two components: the global
routing solution, and the performance of the final power grid, and these results are shown
in Tables II and III, respectively. The wire congestion results of PSiCo are compared in
Table II against the results of the traditional rip-up-and-reroute method, which corresponds
to the result at the end of Step 1 in Section V. For each circuit, the maximum density Dmax,
calculated as the maximum ratio of the utilization to the capacity across any tile boundary.
Also shown is the overflow, i.e., the total amount by which the tile boundary capacities are
violated, summed over all boundaries. It can be seen that for all the cases PSiCo gives much
better congestion results than the conventional method.
Performance metrics for the initial power grid and the power grid obtained by PSiCo
-
22
Circuit Method Dmax Overflowapte Traditional 2.50 28
PSiCo 1.67 3ac3 Traditional 2.20 251
PSiCo 1.00 0ami33 Traditional 3.33 109
PSiCo 1.00 0ami49 Traditional 1.88 195
PSiCo 1.00 0playout Traditional 1.90 154
PSiCo 1.00 0hc7 Traditional 1.50 111
PSiCo 1.00 0a9c3 Traditional 1.43 198
PSiCo 1.00 0
TABLE II
A comparison of the congestion improvement after global routing using the
conventional approach and our new method.
are listed in Table III, in specific, the power wire area as a percentage of the area available
on the two layers, the total number of nodes, the number of wires (W ) in the power grid
and the worst-case voltage drop. Theses numbers after optimization are also shown in the
table and may be compared with the corresponding numbers before optimization. It can be
seen that an optimal grid that takes less percentage of the total chip area can still provide
the sufficient amount of resources needed for signal routing.
Circuit Before Optimization After OptimizatioinArea Nodes W Drop Area Nodes W Drop Z (V × ns)
apte 16.8% 3411 133 0.178V 14.0% 3318 121 0.165V 0.00ac3 20.9% 10984 169 0.177V 14.5% 8736 133 0.171V 0.21e-3ami33 16.1% 11267 171 0.178V 10.9% 8859 133 0.167V 0.00ami49 17.4% 17360 179 0.179V 13.2% 15398 152 0.173V 1.49e-3playout 19.3% 22414 233 0.177V 14.7% 16627 195 0.172V 0.62e-3hc7 18.5% 27288 237 0.176V 12.5% 22160 208 0.177V 9.76e-3a9c3 19.3% 31193 251 0.178V 13.7% 28168 216 0.175V 1.49e-2
TABLE III
Optimal power grid results.
In each of the test cases, all grids whose worst-case voltage drop exceeds 0.14V (stricter
than 10%Vdd because layers M3 and M4 instead of M1 and M2 are considered) are marked
-
23
as critical wires not to be removed. The voltage drop constraint (noise margin) for noise
computation is chosen to be 0.17V, which is slightly stricter than 10%Vdd. To aid the rate of
convergence, we heuristically terminate the SQP solver when we detect that the worst-case
voltage drop in the circuit is below 0.18V, and it can be seen that the worst-case voltage drop
always satisfies this requirement. We choose 5.8×105A/cm2 [19] as the maximum current
density limit in our experiment. The current density based wire width widening slightly
increases the total wire area and therefore the worst-case voltage drop becomes better than
10%Vdd for all the testcases. The optimized noise integral, Z, for each circuit can be seen to
be very small, and is nonzero due to the fact that voltage drops between 0.17V and 0.18V
are tagged as “violations” by the SQP solver.
Table IV lists the total number of iterations and the CPU time, in minutes, required for
each circuit. It can be seen that the number of iterations is typically small, and that the
CPU times for these circuits are very reasonable.
apte ac3 ami33 ami49 playout hc7 a9c3CPU (min) 5.7 14.2 19.36 21.84 44.32 69.48 59.58# Iter. 5 5 6 5 4 4 4
TABLE IV
CPU time statistics and number of iterations for the benchmarks.
Lastly, Table V shows the percentage change in the area of power wires, in each itera-
tion, at the three stages of our power grid design scheme: congestion driven wire removal
(“Removal” in the table), voltage constrained wire sizing (“Sizing” in the table) and current
density-based power grid resizing (“Resizing” in the table). A positive sign indicates an
area increase while a negative sign indicates an area reduction. It is obvious that in the
first stage of wire removal, this is negative, while in the third stage of current density-based
resizing, it is positive, and this is seen in our results. In most of the cases, in the second
-
24
stage where the SQP solver is applied, the total wire area is reduced, although in iteration
4 and 5 of “ami49”, the SQP solver has to increase the total wire area to meet the voltage
drop constraint.
apte ac3 ami33 ami49 playout hc7 a9c3
1 Removal -6.88% -4.83% -6.69% -4.46% -4.44% -4.42% -4.51%Sizing -1.39% -2.70% -2.19% -13.8% -4.10% -4.62% -5.06%Resizing +0.10% +0.24% +0.09% +0.07% +0.83% +0.06% +0.06%
2 Removal -2.31% -4.32% -6.92% -3.86% -4.79% -4.38% -4.64%Sizing -1.42% -2.79% -2.28% -0.27% -3.56% -4.57% -5.31%Resizing +0.02% +0.16% +0.05% +0.20% +0.25% +0.27% +0.16%
3 Removal -0.00% -4.47% -6.47% -4.14% -1.79% -3.64% -4.47%Sizing -1.75% -2.93% -2.33% -0.08% -3.42% -17.4% -4.76%Resizing +0.02% +0.06% +0.06% +0.08% +0.06% +1.50% +0.33%
4 Removal -0.00% -4.68% -2.51% -1.44% -1.95% -0.31% -1.31%Sizing -2.03% -2.87% -2.22% +0.75% -3.61% -0.00% -4.61%Resizing +0.02% +0.19% +0.06% +0.05% +0.06% +0.25% +0.36%
5 Removal -0.00% -4.86% -0.00% -0.00%Sizing -2.31% -2.60% -2.74% +0.48% (converged) (converged) (converged)Resizing +0.03% +0.39% +0.07% +0.05%
6 Removal -1.19%Sizing (converged) (converged) -2.93% (converged)Resizing +0.07%
TABLE V
Percentage change in the area in each stage of every iteration.
Figure 6 shows the congestion map (29x28) of circuit ac3 after the initial routing. The
overflow value on each tile boundary corresponds to the width of the dark line, so that
congested regions are clearly identified. Through a transient simulation of the initial power
grid circuit, the worst-case voltage drop for nodes on layers M3 and M4 are analyzed and
shown as a contour plot in Figure 7. In Figure 7, the small ovals represent GND c4 locations.
Only the ground plane is shown because our experiments show voltage drops in the ground
plane are dominant for this circuit. Hot spots are plotted as darkest regions in the figure. The
chip cell placement and the final optimal power grid are shown in Figure 8. By examining
Figures 6 and 7 and the locations and widths of power wires in Figure 8 it can be seen that
power wires away from hot spots and across congested tile boundaries have been removed
and wider and/or denser power wires lie around hot spots. However, the widths of the wires
-
25
cannot be seen easily in Figure 8 due to the limited resolution. Figure 9 shows the ground
plane worst-case voltage drop contour plot for layers M3 and M4 of the final optimal power
grid.
Fig. 6. Congestion map after the initial routing. Fig. 7. Initial voltage drop contour on the groundplane.
Fig. 8. Optimal M3 and M4 power grid of ac3. Fig. 9. Voltage drop contour on the ground planeof the optimal power grid.
-
26
VII. Conclusion
We have proposed a new design flow for the codesign of signal routes and power grids.
The technique is guided by congestion maps, and proceeds by removing non-critical power
wires greedily in congested areas, and rerouting the signal wires according to the updated
congestions. The effects of removing power wires are compensated for by a gradient-based
wire sizing for voltage noise and a heuristic wire widening for the current density limit.
Experimental results for several benchmark circuits are presented in this paper. Future
work includes incorporating the multigrid idea into our flow and constructing a reliable
back-mapping scheme according to the optimal power grid area and density at the coarse
level.
References
[1] C. J. Alpert, J. Hu, S. S. Sapatnekar, and P. G. Villarrubia. A Practical Methodology
for Early Buffer and Wire Resource Allocation. In Proc. Design Automation Conference,
pages 189–194, Las Vegas, NV, June 2001.
[2] C. J. Alpert, T. C. Hu, J. H. Huang, A. B. Kahng, and D. Karger. Prim-Dijkstra
Tradeoffs for Improved Performance-Driven Routing Tree Design. IEEE Transactions
on Computer-Aided Design of ICs and Systems, 14(7):890–896, July 1995.
[3] P. T. Boggs and J. W. Tolle. Sequential Quadratic Programming. Cambridge Univ. Press,
Cambridge, 1995.
[4] H. H. Chen and D. D. Ling. Power Supply Noise Analysis Methodology for Deep-
Submicron VLSI Chip Design. In Proc. Design Automation Conference, pages 638–643,
Anaheim, CA, June 1997.
[5] H. H. Chen and J. S. Neely. Interconnect and Circuit Modeling Techniques for Full-
-
27
Chip Power Supply Noise Analysis. IEEE Transactions on Components, Packaging, and
Manufacturing Technology, Part B, 21(3):209–215, August 1998.
[6] C. Chiang and M. Sarrafzadeh. Global Routing Based on Steiner Min-max Tree. IEEE
Transactions on Computer-Aided Design, 9(12):1318–1325, December 1990.
[7] A. R. Conn, R. A. Haring, and C. Visweswariah. Noise Considerations in Circuit Opti-
mization. In Proc. International Conference on Computer-Aided Design, pages 220–227,
San Jose, CA, November 1998.
[8] S. W. Director and R. A. Rohrer. The Generalized Adjoint Network and Network Sen-
sitivities. IEEE Transactions on Circuit Theory, 16(3):318–323, August 1969.
[9] P. Feldmann, T. V. Nguyen, S. W. Director, and R. A. Rohrer. Sensitivity Computation
in Piecewise Approximation Circuit Simulation. IEEE Transactions on Computer-Aided
Design of ICs and Systems, 10(2):171–183, February 1991.
[10] P. E. Gill, W. Murray, M. A. Saunders, and M. H. Wright. User’s Guide for
SOL/QPSOL: A Fortran Package for Quadratic Programming. Department of Oper-
ations Research, Stanford University, July, 1983.
[11] J. Hu and S. S. Sapatnekar. A timing-constrained algorithm for simultaneous routing
of multiple nets. In Proc. International Conference on Computer-Aided Design, pages
99–103, San Jose, CA, 2000.
[12] J. N. Kozhaya, S. R. Nassif, and F. N. Najm. Fast Power Grid Simulation. In Proc.
Design Automation Conference, pages 156–161, Los Angeles, CA, June 2000.
[13] J. D. Z. Ma and L. He. Simultaneous Signal and Power Routing under Keff Model. In
Proc. International Workshop on System-Level Interconnect Prediction, pages 175–182,
Sonoma, CA, 2001.
[14] J. D. Z. Ma and L. He. Towards Global Routing With RLC Crosstalk Constraints. In
-
28
Proc. Design Automation Conference, pages 669–672, New Orleans, LA, 2002.
[15] T. Mitsuhashi and E. S. Kuh. Power and Ground Network Topology Optimization for
Cell-based VLSIs. In Proc. Design Automation Conference, pages 524–529, Anaheim,
CA, June 1992.
[16] R. Nair. A Simple Yet Effective Technique for Global Wiring. IEEE Transactions on
Computer-Aided Design, 6(2):165–172, March 1987.
[17] S. R. Nassif and J. N. Kozhaya. Fast Power Grid Simulation. In Proc. Design Automa-
tion Conference, pages 156–161, Los Angeles, CA, June 2000.
[18] L. T. Pillage, R. A. Rohrer, and C. Visweswariah. Electronic and System Simulation
Methods. McGraw-Hill, New York, NY, 1995.
[19] Semiconductor Industry Association, http : //public.itrs.net/F iles/1999 SIA Roadmap.
The International Technology Roadmap for Semiconductors, 1999.
[20] E. Shragowitz and S. Keel. A global router based on a multicommodity flow model.
Intergration: the VLSI Journal, 5(1):3–16, March 1987.
[21] H. Su, K. H. Gala, and S. S. Sapatnekar. Fast Analysis and Optimization of
Power/Ground Networks. In Proc. International Conference on Computer-Aided De-
sign, pages 477–480, San Jose, CA, November 2000.
[22] H. Su, S. S. Sapatnekar, and S. R. Nassif. An Algorithm for Optimal Decoupling Ca-
pacitor Sizing and Placement for Standard Cell Layouts. Proc. International Symposium
on Physical Design, 2002.
[23] X. Tan, C. J. R. Shi, D. Lungeanu, J. Lee, and L. Yuan. Reliability-Constrained Area
Optimization of VLSI Power/Ground Networks Via Sequence of Linear Programmings.
In Proc. Design Automation Conference, pages 156–161, New Orleans, LA, June 1999.
[24] B. S. Ting and B. N. Tien. Routing and Techniques for Gate Array. IEEE Transactions
-
29
on Computer-Aided Design, 2(4):301–312, October 1983.
[25] K. Wang and M. Marek-Sadowska. On-chip Power Supply Network Optimization using
Multigrid-based Technique. In Proc. Design Automation Conference, pages 113–118, Los
Angeles, CA, June 2003.
[26] X. Wu, X. Hong, Y. Cai, C. K. Cheng, J. Gu, and W. Dai. Area Minimization of
Power Distribution Network using Efficient Nonlinear Programming Techniques. In Proc.
International Conference on Computer-Aided Design, pages 153–157, San Jose, CA 2001.
[27] M. Zhao, R. V. Panda, S. S. Sapatnekar, T. Edwards, R. Chaudhry, and D. Blaauw.
Hierarchical Analysis of Power Distribution Networks. In Proc. Design Automation Con-
ference, pages 481–486, Los Angeles, CA, June 2000.
Appendices
A. Power grid analysis
The behavior of the linear circuit discussed in Section III is described using the modified
nodal analysis [18] equation:
Gx(t) + Cẋ(t) = u(t) (6)
where x is a vector of node voltages and source and inductor currents; G is the conductance
matrix; C includes both the decoupling capacitance and package inductance terms, and u(t)
includes the loads and voltage sources.
By applying the Backward Euler integration formula [18] to Eqn. (6), we have:
(G + C/h)x(t + h) = u(t + h) + x(t)C/h (7)
where h is the time step for the transient analysis. If h is kept constant, only a single initial
factorization of the matrix G + C/h is required (as is done in [17,27]) leading to an efficient
algorithm for transient analysis where each time step requires only a forward/backward
-
30
solution step. After the transient analysis of the circuit, the voltage waveform at every node
and the current waveform across every circuit branch are known.
B. Sensitivity computation
Adjoint sensitivity analysis is a standard technique for circuit optimization where the
sensitivity of one performance function with respect to many parameter values is required
[8, 9, 18]. We use a method developed in [22] to find the sensitivity of the scalar function Z
described by Eqn. (4) with respect to every tuning parameter in the circuit. The only minor
difference is that in [22], the tuning parameter is the set of decap widths, while in this work,
it corresponds to the width of each wire in the power grid.
The sensitivity of noise Z with respect to all of the resistors in the circuit can be com-
puted from the following convolution [8, 9]:
∂Z
∂R=
∫ T
0ϕR(T − t)iR(t)dt, (8)
where ϕR(τ) is the current waveform flowing through the resistor R in the adjoint circuit.
The memory storage and speed problem for the waveform convolution is solved by ap-
plying a piecewise linear technique proposed in [22]. The complexity of the convolution
calculation over [0, T ] is O(N + M), where N and M are the number of linear segments on
the original and adjoint current waveforms.
The sensitivities to the width of each wire width can then be calculated using the chain
rule:
∂Z
∂w=
P∑
i=1
∂Z
∂Ri×
∂Ri∂w
, (9)
where P is the total number of segments in one grid wire with the same width w. Since the
resistance Ri = ρli
w h, where li the length of the wire segment, w is the width of the wire,
h and ρ are the thickness and resistivity of the metal layer that the power wire lies in, it is
-
31
easily verified that Eqn. (9) becomes:
∂Z
∂w= −
P∑
i=1
∂Z
∂Ri×
ρ lih w2
(10)