SV 104 Personal Noise Dosimeter Powerful Noise Measurement for Improved Worker Safety and Hearing Protec=on Selec=on
![Page 2: A Better Noise Dosimeter](https://reader033.vdocuments.us/reader033/viewer/2022052505/5569173ed8b42aa8138b48fe/html5/thumbnails/2.jpg)
A More Powerful Noise Dosimeter
¤ Noise dosimeters serve an important role in protec1ng workers in noisy environments
¤ Conven1onal noise dosimeters provide simple dose measurements during noise surveys required by regula1on
¤ Hearing protec1on and long-‐term conserva1on decisions are achieved through comprehensive measurements using mul1ple surveys or advanced tools
![Page 3: A Better Noise Dosimeter](https://reader033.vdocuments.us/reader033/viewer/2022052505/5569173ed8b42aa8138b48fe/html5/thumbnails/3.jpg)
Introducing the SV 104
¤ The SV 104 is fully compliant for workplace noise monitoring and introduces features and capabili1es previously unavailable with any personal noise dosimeter
¤ The SV 104 is a wireless personal noise dosimeter with Enhanced Design, Precision Measurement, Results VerificaAon, and Data Analysis & ReporAng
![Page 4: A Better Noise Dosimeter](https://reader033.vdocuments.us/reader033/viewer/2022052505/5569173ed8b42aa8138b48fe/html5/thumbnails/4.jpg)
SV 104: Enhanced Design
¤ Greater Shock & Damage Resistance – Rugged enclosure – MEMs solid-‐state microphone
¤ Color OLED Display – Easy to read in direct sunlight
or dim ligh1ng – High-‐contrast for visibility
¤ Simple Three BuNon Interface – Lockable to resist tampering
![Page 5: A Better Noise Dosimeter](https://reader033.vdocuments.us/reader033/viewer/2022052505/5569173ed8b42aa8138b48fe/html5/thumbnails/5.jpg)
SV 104: Enhanced Design
¤ Compact Size & Lightweight – Reduces intrusion on worker
ac1vi1es – Weighs only 3.5 ounces /
100 grams including baNeries
¤ LED Measurement Indicator – Warning of dose level
exposure – Ac1ve survey indica1on
![Page 6: A Better Noise Dosimeter](https://reader033.vdocuments.us/reader033/viewer/2022052505/5569173ed8b42aa8138b48fe/html5/thumbnails/6.jpg)
SV 104: Precision Measurement
¤ Three Independent Dosimeter Measurements – Simultaneous OSHA PEL, OSHA
HCA, and ACGIH – Customizable configura1ons – Time and cost savings over
mul1ple surveys
¤ Real-‐1me Octave Band Analysis – Providing hearing protec1on
selec1on data – Greater accuracy than C minus A – Single survey provides dose
exposure and data for correc1ve ac1ons
![Page 7: A Better Noise Dosimeter](https://reader033.vdocuments.us/reader033/viewer/2022052505/5569173ed8b42aa8138b48fe/html5/thumbnails/7.jpg)
SV 104: Precision Measurement
¤ Wide Measurement Range – 55 dBA RMS to 140.1 dBA Peak – 30 Hz to 8 kHz Frequency Range – 95 dB Dynamic Range
¤ Configurable Measurements – A, C, and Z Weigh1ng – 5, 3 (plus 2, 4, and 6) Exchange
rates – Lavg/Leq, SPL, Max, Min, SEL, SEL8,
PSEL, LEPd, Dose (%), TWA, E, E_8h, Peak, Run Time, Upper Limit Time, L(C-‐A), Projected Dose
![Page 8: A Better Noise Dosimeter](https://reader033.vdocuments.us/reader033/viewer/2022052505/5569173ed8b42aa8138b48fe/html5/thumbnails/8.jpg)
SV 104: Results VerificaAon
¤ Audio Recording – Iden1fy noise-‐sources above
trigger level by playback of recorded audio
– Configurable -‐ recording func1on may be turned off for classified or privacy-‐enforced areas
¤ Triaxial Vibra1on Sensor – Records instrument impacts
contribu1ng to audio spikes or peaks
– Verified false spikes can be removed from dose calcula1ons for greater accuracy
40
50
60
70
80
90
100
110
120 LAV TWA
![Page 9: A Better Noise Dosimeter](https://reader033.vdocuments.us/reader033/viewer/2022052505/5569173ed8b42aa8138b48fe/html5/thumbnails/9.jpg)
70
75
80
85
90
95
SV 104: Data Analysis & ReporAng
¤ On-‐board 8 GB Micro SD Card – Large data storage capacity – Common USB interface for data
download
¤ Datalogged Summary Results – Time history of Leq, Max, Min,
Peak with 1-‐second logger step
¤ Raw Data Format – Downloaded data can be used
with provided Supervisor applica1on or exported
![Page 10: A Better Noise Dosimeter](https://reader033.vdocuments.us/reader033/viewer/2022052505/5569173ed8b42aa8138b48fe/html5/thumbnails/10.jpg)
SV 104: Data Analysis & ReporAng
¤ “Supervisor” Sojware – Customizable viewing of results
data – Report genera1on using pre-‐
set or configurable templates – Historical database for
managing results and determining threshold shijs
¤ Instrument Manager – Setup dosimeter measurement
func1ons and op1ons – Create profiles for common
survey applica1ons
![Page 11: A Better Noise Dosimeter](https://reader033.vdocuments.us/reader033/viewer/2022052505/5569173ed8b42aa8138b48fe/html5/thumbnails/11.jpg)
A company of the SCHAUENBURG International Group
Svantek SV 104 The Most Powerful and Versa1le Noise Dosimeter on the Market.