1
SHEET
of
ALLPLANS
11
11
2 J
oh
n G
alt
Blv
d.
Om
ah
a,
NE
68
13
7
To
ll f
ree:
(80
0)
94
7-7
52
6
Fax:
(402)
331-5
507
REVERSEAVAILABLE
customizable
ww
w.d
esig
nb
asics.c
om
TH
E P
UR
CH
ASE
R O
F T
HE
SE P
LA
NS
IS G
IVEN
A L
IMIT
ED L
ICEN
SE
TO
RE
PRO
DU
CE
TH
ESE
PL
AN
S
FOR
CO
NST
RU
CT
ION
PU
RPO
SES
ON
LY
AN
D F
UR
TH
ER
DIS
TR
IBU
TIO
N
IS S
TR
ICT
LY
PR
OH
IBIT
ED
....W
HE
RE
G
RE
AT
D
ES
IG
N M
AT
TE
RS
DE
SIG
N B
ASI
CS,
LL
C. I
S A
PR
OFE
SSIO
NA
L R
ESI
DE
NT
IAL
DE
SIG
N F
IRM
LO
CA
TE
D IN
OM
AH
A, N
E. B
EC
AU
SE S
ITE
CO
ND
ITIO
NS
MA
Y V
AR
Y D
ESI
GN
BA
SIC
S, L
LC
. CA
NN
OT
WA
RR
AN
T T
HE
SU
ITA
BIL
ITY
OF
TH
ESE
PL
AN
S FO
R U
SE
ON
YO
UR
SPE
CIF
IC S
ITE
. C
ON
STR
UC
TIO
N F
RO
M T
HE
SE
PLA
NS
SHO
UL
D N
OT
BE
UN
DE
RT
AK
EN
WIT
HO
UT
TH
E
ASS
IST
AN
CE
OF
A C
ON
STR
UC
TIO
N P
RO
FESS
ION
AL
.
TOP VIEW
4" [101.60mm]
758
" [193.68mm]
1’-034
" [323.85mm]
758
" [193.68mm]
8" [203.20mm]
4" [101.60mm]
3’-8" [1117.60mm]
6" [
152.4
0m
m]
1’-038
" [314.33mm]
1114
" [285.75mm]
1’-838
" [517.53mm]
4" [
101.6
0m
m]
111 4
" [
28
5.7
5m
m]
1’-
03 8" [
31
4.3
3m
m]
75 8
" [
19
3.6
8m
m]
NOTE:
SEE PRODUCT DETAILS FOR REBAR PLACEMENT DIMENSIONS.
OFF-CENTERCENTER
INTERIOREXTERIOR
CLEAR COVER DIMENSION WILL DEPEND ON SIZE OF HORIZONTAL AND VERTICAL REBAR.
6" [152mm]
258
" [67mm]258
" [67mm]
1114
" [286mm]
1" [25 mm] MIN
2" [51 mm] MAX
6" [152mm]
258
" [67mm]258
" [67mm]
1114
" [286mm]
3" [76mm]3" [76mm]
FOX "A" "B"
14" [356mm]8" [152mm]4"
16" [406mm]8" [203mm]6"
18" [457mm]10" [254 mm]8"
FOX CORNER BAR SPACING
10" 12" [305mm] 16" [508mm]
90%%d CORNER REBAR,
LAP REBAR 40 BARDIAMETERS, MINIMUM
VERTICAL BARS,
AS REQUIRED
AS REQUIRED
HORIZONTAL BARS,
"A"
"B"
"A"
"B"
12" 14" [356mm] 22" [559mm]
90%%d FOX BLOCK
FOX BLOCK FORMS
PROVIDE DOWELS BETWEEN POURS
AS SPECIFIED
VERTICAL REBAR AS SPECIFIED
VERTICAL CONSTRUCTION JOINT
HORIZONTAL REBAR AS SPECIFIED
ELEVATION VIEW
REINFORCING AS SPECIFIED.
CONTINUOUS FOOTING - SIZE AND
SLOPED FINISHED GRADE
DRAIN TILE
THERMAL BARRIER
15-MINUTE
GRANULAR FILL
REBAR DESIGN AND PLACEMENT
CONCRETE FLOOR
UNDISTURBED SOIL
AGGREGATE
AS SPECIFIED
STRAIGHT VERTICAL DOWELOR HOOK AS SPECIFIED.
PARGING
DAMP PROOFING OR
WATERPROOF MEMBRANE
AS PER CODE
PARGING
SILL PLATE
ANCHOR AS
REQUIRED BY CODE
REINFORCING AS SPECIFIED.
CONTINUOUS FOOTING - SIZE AND
THERMAL BARRIER
15-MINUTE
FOX BLOCK FORMS
HORIZONTAL REBAR AS SPECIFIED
VERTICAL REBAR AS SPECIFIED
DOWELS AS SPECIFIED
(IF REQUIRED)
HEIGHT AS
SPECIFIED
UNDISTURBED SOIL
OR BEDROCK
DRAIN TILE
AGGREGATE
FILTER CLOTH,
IF NEEDED
EPS INSULATION
(IF REQUIRED)
BASE AS SPECIFIED
EXTERIOR FINISH
ROOF SYSTEM
FOX BLOCK
SLOPED FINISHED GRADE
INSULATION
FIRST FLOOR
BASEMENT
PARGING
EXTERIOR FINISH
CONCRETE FLOOR
GRANULAR FILL
VAPOR RETARDER
FLOOR FRAMING
RIM JOIST WITH ANCHOR BOLTS
ROOF DETAIL
THERMAL BARRIER
15-MINUTE
THERMAL BARRIER
15-MINUTE
DRAIN TILE
AGGREGATE
DAMP PROOFING OR
WATERPROOF MEMBRANE
AS PER CODE
C
1
2014
FO
X B
LO
CK
SS
EC
TIO
NS
SECOND FLOOR
FIRST FLOOR
BASEMENT
THERMAL BARRIER
15-MINUTE
THERMAL BARRIER
15-MINUTE
ROOF SYSTEM
INSULATIONROOF DETAIL
RIM JOIST WITH ANCHOR BOLTS
CONCRETE FLOOR
GRANULAR FILL
VAPOR RETARDER
SLOPED FINISHED GRADE
PARGING
DRAIN TILE
AGGREGATE
FOX BLOCK
EXTERIOR FINISHFLOOR FRAMING
DAMP PROOFING OR
WATERPROOF MEMBRANE
AS PER CODE
FLOOR JOIST
EXTERIOR FINISH
JOIST HANGER
RIM JOIST
ANCHOR BOLTS PER TABLE
FLOOR DECKING
FOX BLOCK
WALL OUT-OF-PLANE ANCHOR
IN SEISMIC DESIGN, BY ENGINEER
OF RECORD
DOUBLE OR STAGGERED
ANCHOR BOLT AS REQUIRED
BY ENGINEER OF RECORD
LAP SPLICE AS REQUIRED
HORIZONTAL REBAR AS REQUIRED
BY ENGINEER OF RECORD
VERTICAL REBAR AS REQUIRED
BY ENGINEER OF RECORD
FLOOR JOIST
15 MINUTE THERMAL BARRIER
(i.e. 1/2" GYPSUM BOARD)
JOIST HANGER
RIM JOIST
ANCHOR BOLTS PER TABLE
FLOOR DECKING
FOX BLOCK
DECK JOIST
WOOD DECK
LEDGER BOARD
HORIZONTAL REBAR AS
REQUIRED BY CODE
VERTICAL REBAR AS
REQUIRED BY CODE
EXTERIOR FINISH
RIM JOIST
SIMPSON ICFLC-W
SIMPSON ICFVL AS REQUIRED
BY ENGINEER OF RECORD
STEEL LEDGER
CONNECT WITH SCREWS
CONNECT WITH SIMPSON SCREWS
SIMPSON ICFVL AS REQUIRED
BY ENGINEER OF RECORDNOTE: SIMSPON STRONG TIE
ICF LEDGER CONNECTION
NOT FOR EXTERIOR USE.
ANCHOR BOLTS
1. ESTABLISH TOP OF JOIST ELEVATION AND MARK THE
FORM WITH A CHALK LINE.
2. ESTABLISH BOTTOM OF JOIST ELEVATION AND MARK THE
FORM WITH A CHALK LINE.
3. 6.5 INCH WIDE BEVELED CUT-OUTS ARE TO BE PROVIDED
IN THE FORM WALL. THE HEIGHT OF THE CUT-OUTS ARE
DETERMINED AS SHOWN IN THE DRAWING ABOVE. (ONE
INCH BELOW THE TOP CHALK LINE AND ONE INCH ABOVE
THE BOTTOM CHALK LINE.
4. SCREW THE RIM JOIST TO THE FORM WEB STRIPS AT THE
PROPER ELEVATION, LABELED "FOX BLOCKS".
5. LAYOUT AND INSTALL THE RIM JOIST ANCHOR BOLTS AS
REQUIRED.
6. FILL THE FORMS WITH CONCRETE AND ALLOW THE
CONCRETE TO CURE BEFORE INSTALLING JOIST HANGERS
OR LOADING THE RIM JOIST.
ANCHOR BOLTS PER TABLE
RIM JOIST
RIM JOIST
SCREWS
VERTICAL REBAR AS
REQUIRED BY CODE
HORIZONTAL REBAR AS
REQUIRED BY CODE
AS REQUIRED
15 MINUTE THERMAL BARRIER
1/2" GYPSUM BOARD
INSULATION
ROOFING
ROOF TRUSS
EXTERIOR FINISH
6 MIL. POLY VAPOUR BARRIER
2x6 PLATE ON SILL GASKET ACHORED
TO CONCRETE AS REQUIRED BY
ENGINEER OF RECORD.
VERTICAL REBAR AS REQUIRED
BY ENGINEER OF RECORD
HORIZONTAL REBAR AS REQUIRED
BY ENGINEER OF RECORD
CLIP ANGLE AT EACH ROOF
FRAMING MEMBER IN SEISMIC
DESIGN, BY ENGINEER OF RECORD
FLOOR JOIST
THERMAL BARRIER
15-MINUTE
FLASHING & WEEP HOLES
xLERATOR AS SPECIFIED
FOX BLOCK FORMS
ACRYLIC PARGING
(OVERLAPS DAMP
PROOFING MEMBRANE)
FOX CORBEL BLOCK FORM
ANCHOR BOLTS PER
CODE REQUIREMENTS
VERTICAL REBAR AS SPECIFIED
HORIZONTAL REBAR AS REQUIRED
THERMAL BARRIER
15-MINUTE
EXTERIOR FINISH
HORIZONTAL BARS
AS REQUIRED
WOOD JOIST
15-MINUTE
THERMAL BARRIER
SUBFLOOR
2 X 4 SILL PLATE ON SILL
SEAL WITH ANCHOR
BOLTS AS REQUIRED
VERTICAL BARS
AS REQUIRED
FOX BLOCK xLerator
REINFORCEMENT
FIRST POUR
SECOND POUR
EXTERIOR FINISH
HORIZONTAL BARS
AS REQUIRED
WOOD JOIST
15-MINUTE
THERMAL BARRIER
SUBFLOOR
2 X 4 SILL PLATE ON SILL
SEAL WITH ANCHOR
BOLTS AS REQUIRED
VERTICAL BARS
AS REQUIRED
FOX xLerator REINFORCEMENT
FIRST POUR
SECOND POUR
TOP CHORD BEARING
FOX BLOCK FORMS
VERTICAL REBAR AS SPECIFIED
HORIZONTAL REBAR AS SPECIFIED
PARTITION WALL
MASONARY SCREW OR ALTERNATE
AS SPECIFIED
REMOVE PORTION OF FORM TO
FACE OF CONCRETE AFTER
CONCRETE POUR
PLYWOOD BACKING TO CONCRETE
INSTALL WOOD BLOCKING OR
WITH CONCRETE FASTNERS